Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0402 PHINNEY'S LANE
k" 's low, 3A MEN -qp `5 q W- AN Hir ug V.1��4, TA- 111�i Rf i IN 0 kJA MA, AQ 'gn MOW �f, :AV5"t�, 0 p,r; is pj� 44 All a I PE ag, quo" -1 "i'll,R-I 1��110% WIN Y jq A�m ggv pg�*tpa' Wp �mj PA It" "A No Qg, 0"N", mi;o P, KP PT, A KV ®R I v .iq "j, 4- P?' 1-1 kh�,, I 1p� -got an q�jlg ggggg' 1 MEN, B"s-m-wamm I- A �T�%�y &TVA N'It� v "'Ie .g out sm9som q-'pxjNN .4, p�p y Nfl w 10 v i,o,�y F"- g" R11W mv Al Vis" OWN Ion= k-11"Ir UPI §wn NMI 04.01y"16, ffiffi Nw, "'N iR*51 M! "ir"ag W�. M.P. 4 N4 ON 4 4'1 V ME= TNi 'Ti �3 1-3Z T OR g; of � Town of Barnstable *Permit# ti • Expires 6 ntortffis from isstre dote Regulatory Serviees Fee ■AMSrABM ¢ e PRE SMI `` * V.Scali,Director Eo�� JUN 0 7 n 2017 Building Division TwA CBo $11v.,.���6d f`y �Perry, wilding Commissioner Il N I r tiro Street,Hyannis,MA 02601 www-town.bamstable.ma-us Office: 508-862-4038 Fax:508-790-6230 EXPRESS PERMIT APPLICATION - RESIDENTIAL ONLY Not Valid without Red X--Press Laprint. Map/parcel Number � ?jam oZ0' Property Address �/O o2 t%i m ey l,S L-✓7, �'c e r✓( l(e� [Residential Value of Work$ 1 3 i 2 3, Minimum fee of$35.00 for work under$6000.00 Owner's Name&Address asS:dy ti i S Ct-Q►l /96sA -1 U i qoz Lane (;-_a&rviffe Tr1A a.ir23 Z Contractor's Name..,�n AfE AL74oubs ( /I tSD/l Telephone Number[4{O f R�O Home Improvement Contractor License#(if applicable) l 73 Z 14 .5 Email: Construction Supervisor's License#(if applicable) 4 7 p-7 [Workman's Compensation Insurance Check one: ❑ I am a sole proprietor ❑ the Homeowner I have Worker's Compensation Insurance Insurance Company Name (29.17 t'a�A � A/es f/'/1 J. i_s K�,, Workman's Comp-Policy# [� Copy of Insurance Compliance Certificate must accompany each permit. Permit Request(check box)- ❑ Re-roof(hurricane nailed)(stripping old shingles) All construction debris will be taken to ❑Re-roof(hurricane nailed)(not stripping. Going over existing layers of roof) ❑ Re-side 2 Replacement Windows/doors/sliders.U-Value 3 Q (maximum 32)#of windows `7 #of doors: ❑ Smoke/Carbon Monoxide detectors 4 floor plans marked with red S and inspections required. Separate Electrical&Fire Permits required. *Where required: Issuance of this permit does not exempt compliance with other town department r gulations,i.e-Historic,Conservation,etc- ***Note: Property caner must sign Property Owner Letter of Permission. . A copy the Home Improvement Contractors License&Construction Supervisors License is require c o SIGNATURE: C:\Users\Decollik\AppData\LocalWicrosoft\tAtindows\Temporary Internet FileAContent.0utlook\21`101 DHR\EXPRESS.doe Revised 040215 r Renewal Agreement Document and Payment Terms byAndersen. dba:Renewal B Andersen of Southern New England� - Y g Cassidy Cofran&Chris Rosario Q� Legal Name:Southern New England Windows,LLC 402 Phinneys Ln. ���i RI#36079, MA#173245,CT#0634555, Lead Firm #1237 Centerville,MA 02632 WINDOW RE IACEMENT 26 Albion Rd I Lincoln,RI 02865 H:(508)813-2832 Phone:866-563-2235 1 Fax:401-633-6602 1 sales®renewalsne.com C:(508)801-9639 Buyer(s)Name: Cassidy Cofran &Chris Rosario Contract Date: 05/23/17 Buyer(s)Street Address: 402 Phinneys Ln., Centerville, MA 02632 Primary Telephone Number: (508)813-2832 Secondary Telephone Number: (508)801-9639 Primary Email: immortalheart3@yahoo.com Secondary Email: idigholz@yahoo.com Buyer(s)hereby jointly and severally agrees to purchase the products and/or services of Southern New England Windows,LLC d/b/a Renewal By Andersen of Southern New England("Contractor"),in accordance with the terms and conditions described in this Agreement Document and Payment Terms,any documents listed in the Table of Contents,and any other document attached to this Agreement Document,the terms of which are all agreed to by the parties and incorporated herein by reference(collectively,this "Agreement"). Buyer(s)hereby agrees to sign a completion certificate after Contractor has completed all work under this Agreement. Total Job Amount: $13,832 By signing this Agreement,you acknowledge that the Balance Due,and the Amount Financed must be made by personal check,bank check,credit card,or cash. Deposit Received: $6,916 Balance Due: $6,916 Estimated Start: Estimated Completion: Amount Financed: $13,832 6-8 weeks 6-8 weeks Method of Payment: Financing We schedule installations based on the date of the signed contract and secondarily on the date in which we complete the technical measurements.The installation date that we are providing at this time is only an estimate.We will communicate an official date and time at a later date. Rain and extreme weather are the most common causes for delay. Notes: 50% deposit-GREEN SKY, 50% balance due upon completion-GREEN SKY Buyer(s)agrees and understands that this Agreement constitutes the entire understandings between the parties and that there are no verbal understandings changing or modifying any of the terms of this Agreement.No alterations to or deviations from this Agreement will be valid without the signed,written consent of both the Buyer(s) and Contractor.Buyer(s)hereby acknowledges that Buyer(s) 1)has read this Agreement,understands the terms of this Agreement,and has received a completed,signed, and dated copy of this Agreement,including the two attached Notices of Cancellation,on the date first written above and 2)was orally informed of Buyer's right to cancel this Agreement. NOTICE TO BUYER:Do not sign this contract if blank.You are entitled to a copy of the contract at the time you sign. YOU,THE BUYER, MAY CANCEL THIS TRANSACTION AT ANY TIME NOT LATER THAN MIDNIGHT OF 05/26/2017 OR THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION, WHICHEVER DATE IS LATER.SEE THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT. Legal Name:Southern New England Windows,LLC dba:Zy BVAdaenenof Southern New England Buyer(s) Signature of Sales Person Signature Signature Chris Hutson Cassidy Cofran Chris Rosario Print Name of Sales Person Print Name Print Name UPDATED: 05/23/17 Page 2 / 11 :ardSassachusetts Department.of Pubiic Saf-et/ of Building Regulations and Standards License: CS-095707 BRIAN D DENNISON 7 LAMBS POND CIRCLE1k " CHARLTON MA 01507:}„ Ex'pi r3ti o'n. Commissioner 09i081.201$ F-ama C zce of Consumer,L\ a:s i- usiness lleau-aClon -' 10 Far Plaza- SLite 5170 Boston, lassacnu etas 027116 Home lmproyem(t 4t vontmctor Reg-station -__ - Registration: 173245 Type: Supplement Card — -_ Expiration: 9/19/201S SOUTHERN NEW ENGUkND W1Nb0VV9,',LL BRIAN DENNISON S _ 28 ALBION RD _- - --- — LINCOLN,RI 92865 + - Ljudate Aaldr-ass and mmrn Lmrd :mason For chio�e. _Address new Employment Last Card Rm of t:nnsamer VTaus 3`tosiatss Itc�mLtnon RePSEM&D valid for individual a5c only ucFare the esuiration date If Sound return to OME IMPROVEMENT CONTRACTOR ,USG�f-ansttmer�,airq and Business Cep^,�aCoc RegistratlPn i7'246.' Tape. 10 Part:PL•m-Suite 51;0 _. iratlan.._9619l261$. Supplement Cartl &uton.NLA 92116 SOUTHERN NEW ENGLAND WINDOWS ULC. RENEWAL BY ANDERSON; BRIAN DENNISON _ - 26 ALBION RD --- UNCOLN.RI 02865 1—Undersecreiarc Not valid without Agnamre The Commonwealth of Massachusetts Department of Industrial Accidents 1 Congress Street, Suite 100 Boston,MA 02114-2017 -,� www.mass.gov/dia Workers' Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual): Sw+4crn he?t~J Erie-,OGt n es W inn d DO'/ S Address: c2& 41&o►-� City/State/Zip: Li/IC //1 I Phone#: ( 40) 2— 9 8 C)O Are you sin employer?Check the appropriate box: Type of project(required): 1.Jaam a employer with employees(full and/or part-time).# 7. ❑New construction 2.❑I am a sole proprietor or partnership and have no employees working for mein 8. ❑Remodeling any capacity. [No workers'comp.insurance required.] 9. ❑Demolition J-1 I am a homeowner doing all work myself[No workers'comp.insurance required.J t ]0 ❑Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole I I.❑Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.❑I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13 ❑Roof repairs These sub-contractors have employees and have workers'comp.insurance.t . J 6.❑We.are a corporation and it officers have exercised their right of exemption per MGL c. 14.[2 ther Gil i r\pw p coo o t- 1527§1(4),and we have no employees.[No workers'comp.insurance required.] /P14 cewn eT *Any applicant that checks box 41 must also fill out the section below showing their workers'compensation policy information. T Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. !Contractors that check this box must attached an additional.sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,the},must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy andjob site information. / / Insurance Company Name: � fi1e✓1�6i I l(e?s tPrri Ins• Cc Policy# or Self-ins.Lic.#: [Al C- � 3 13 bD�' 1 Expiration Date: - 1 — T Job Site Address: �/b L tit 0do V yl e City/State/Zip: !// A Attach a copy of the workers' compensation policy declaration page(showing.the policy number and a piration date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal violation punishable by a fine up to$3,500.00 . and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the p i sand penalties of perjury•that the information provided above is true and correct. Signature: Date: 17 Phone#: Official use only. Do not write in this area, to be completed by city or town officiaL City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: SOUTNEW-01 UOLLINGER �. CERTIFICATE OF LIABILITY INSURANCE DATE(dIMIDDIYYYY). 6129/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER: IMPORTANT: If the certificate holder is an ADDITIONAL.INSURED,.the policy(ies)must be endorsed. If SUBROGATION IS WANED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAM.= CoBiz Insurance,Inc.-CO PHONE FAX $21 17th St. Alc Ne E,R:(303)988.,0446 AI No)*(303)988-0804 Denver,CO 80202 EA ASS:Co.Bizinsurarkc obizinsurance.com INSUREM AFFORDING COVERAGE NAIC B INSURER A:Continental Westem Insurance Company 110804 INSURED INSURER B: Southern New England Windows LLC INSURER C DBIA Renewal by Andersen ! 26 Albion Road >wsuRER D Lincoln,RI 02865 INSURER.E: INSURER:F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED.BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE.POLICIES DESCRIBED HEREIN IS SUBJECTTO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED-BY PAID CLAIMS._ INSR TYPE OF INSURANCEBRl POLICY EFF . POLICY INSD'I WVD POLICY NUMBER LfArIrS A X COMMERCIAL GENERAL LIABILITY i I i i I :EACH OCCURRENCE 5 1,000,00 CLAIMS-MADE n OCCUR ICPA3136080 107101120 107101/2017 PREMISES oeamance i 5 100,00 i MED EXP(Arty one person)) S 10,00 PERSONAL&ADV INJURY I S 1,000,00Q GEN'L AGGREGATE LIMIT APPLIES PER: I ( I I GENERAL AGGREGATE S 2,000,000 X POLICY I`_j ECT LOC ' ! j PRODUCTS-COMPIOP AGG ;5 2,000,00 i 2,000,000 EFI !5 ! OTHER i EMPLOYEE BEN . COMBINm SINGLE LIMIT •S 1,000.000 I I AUTOMOBILE LUU311JTY i , ..Ea aca"derft I A �' I i CPA3136080 0710112016!07/MMM71 BODILY INJURY(Perpwrso).15_ ANY AUTO ALL OWNED 'SCHEDULED _`y IN . AUTOS :AUTOS I BODILY INJURY(Per acadent) S i I__j NON-OWMED i j ! !PROPERTY DAMAGE 5 HIREDAUTOS AUTOS darft s I X UMBRELLA LIAB jIX OCCUR EACH OCCURRENCE S S,OOO;000 A EXCESS LIAB CLAIMS MADE + ICPA3136080 07/01/2016 10710112017 AGGREGATE j 5 DED X. RETENTION S 0� I I I ggregate I S 5;000,00 WORI�RSCOMPENSATION P TH AND EMPLOYERS LIABILITY Y 1 N I I I I STATUTE 4 OOO 00 A ANY PROPRIETOR/PARTNER/EXECUTIVE hNCA3136081 0710112016 1071011201T E.L.EACH ACCIDFM S r , OFFICERIMEMBER EXCLUDED? NIA A I I (Mandatory In NH) j f E.L.DISEASE-EA EMPLOYE $ 1,000,000 If yes,desaibe under i 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ � • I ' i � I DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,AddlHOMI Remarlos Schedule,may be attached K more apace Is required) ,dl CERTIFICATE-HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED-BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORDEDREPRESENTATIVE ©1.988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Map �. Parcel o�p� T��'V'.J ': " �Tr� L ^ /Application # b- 57 Health Division ?' "' g hit ` Date Issued 3 /W Conservation Division Application Fee Planning Dept. Permit Fee Date Definitive Plan Approved by Planning Board' Historic - OKH IV D _ Preservation / Hyannis f) Project Street Address a b �h c hnev 5 h eN Village Ce-n v-v: Owner 06L56 act C Ohns. Vir_r M . RoSAOAddress IYO;;l Telephone �`� 1 .2�2�,�� Ct �, lic y �i8� uaa Permit Request .k� 56 e_c rw�-- o�- c;? 15 \..�i ,t �t•,c L Square feet: 1 st floor: existing proposed — 2nd floor: existing proposed _ Total new Zoning District b- I _Flood Plain Groundwater Overlay Project Valuation babes Construction Type Lot Size Grandfathered: ❑Yes ❑ No If yes, attach supporting documentation. Dwelling Type: Single Family Two Family ❑ Multi-Family(# units) Age of Existing Structure CS . Historic House: ❑Yes AP-No On Old King's Highway: ❑Yes ANo Basement Type: ❑ Full. ❑ Crawl ❑Walkout ❑ Other Basement Finished Area (sq.ft.) Basement Unfinished Area (sq.ft) Number of Baths: Full: existing new Half: existing new Number of Bedrooms: existing _new Total Room Count (not including baths): existing new First Floor Room Count Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑ Other Central Air: ❑Yes ❑ No Fireplaces: rAExixisting New Existing wood/coal stove: ❑Yes ❑ No Detached garage: ❑ existing ❑ new size+`1 Fool: ❑existing ❑ new size Barn: ❑ existing ❑ new siz Attached garage: ❑ existing ❑ new sizAAhed: ❑ existing ❑ new sizeOther: Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑Yes ONo --If yes, site plan review # Current Use Proposed Use D h APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Name D l.(- ��1 i&I- � * 4 Telephone Number y 6 v 3A Address S u \oU License # (2-57t)e—YX hk CJa-GG b Home Improvement Contractor# Email �'I CCT1V Worker's Compensation # ALL CON RUCTION DEBRIS RESULTIN F U M THIS PROJECT WILL BE TAKEN TO a OS�'� r. .� DATE SIGNATURE FOR OFFICIAL USE ONLY APPLICATION # DATE ISSUED MAP/PARCEL NO. i ADDRESS VILLAGE y OWNER DATE OF INSPECTION: FOUNDATION FRAME INSULATION FIREPLACE ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH FINAL GAS: ROUGH FINAL FINAL BUILDING 6 1 DATE CLOSED OUT ASSOCIATION PLAN NO. f DocuSign Envelope ID:89E0023A-SFD3-464D-8C5A-278E9056412E a SolarCity I SolarLease Customer Name and Address Installation Location Date Cassidy Cofran 402 Phinneys Ln 3/1/2016 402 Phinneys Lane Centervil,MA 02632 . Centerville,MA 02632 >.s � ro n ��y .r�;y'., 3<'.�4 •;h"�F,. Here are the key terms of your SolarLease Agreement L w I, (r'� 3 Amount due at contract signing g g First year monthly0ayment Agreeme am (Est.Price per kWh F F Initial ere far.$0.1370) Initial ere _ 0 The SolarCity Promise os •We provide a money-back energy performance guarantee. •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement.'.........................................................................Initial here •We warrant all of our roofing work. os •We restore your roof at the end of the Agreement. •We warrant,insure and repair the System. ...............................:....................................................................................................................................................:..............................................................Initial her •We fix or pay for any damage we may cause to your property. •We provide 24/7 web-enabled monitoring at no additional cost. ' •The rate you pay us will never increase by more than 2.90%per year. •The pricing in this Agreement is valid for 30 days after 3/1/2016. 0 Your SolarCity Lease Agreement Details Your Choices at the End of the Initial Your Prepayment Choices During Amount due at contract signing +7t Term: the Term: s�;. Y $0 __ _ _ __ •SolarCity will remove the System at no •If you move,you may prepay the Est.amount due at Installation , additional cost to you. remaining payments(if any)at a $0 •You can upgrade to a new System with discount. the latest solar technology under a new Est.amount due at building inspection contract. $`0 �- � "� •You may renew your Agreement for up to Est.first year production ten(10)years in two(2)five(5)year 7985 kWh + increments. __ � .� •Otherwise,the Agreement will automatically renew for an additional one (1)year term at 10%less than the then- current average rate charges by your local utility. 3055 Clearview Way,San Mateo,CA 94402 888.765.2489 solarcity.com 1620164 SolarLease Agreement,version 7.1.3,February 15,2016 SAPC/SEFACompliant Q• ,a Contractor License MA HIC 168572/EL-1136MR Document generated on 3/1/2016 Copyright 2008-2015 SolarCity Corporation,All Rights Reserved a DocuSign Envelope ID:85E0023A-8FD3-464D-8C5A-278E9056412E 1. INTRODUCTION 3. SYSTEM DESCRIPTION This SolarLease®(this"Lease"or"Agreement")is the Lease and installation of a 8.16 kW DC photovoltaic agreement between you and SolarCity Corporation system consisting of PV modules,corresponding (together with its successors and assigns,"SolarCity"or inverter(s)and a mounting system designed for "we"),covering the lease to you of the solar panel installation and operation at your Home. system (the"System")described below.The System will be installed by SolarCity at the address you listed REST OF PAGE INTENTIONALLY LEFT BLANK. above.This Lease will refer to this address as the "Property"or your"Home."This Lease is up to thirteen (13) pages long and has up to three(3) Exhibits depending on the state where you live.This Lease has disclosures required by the Federal Consumer Leasing Act and,where applicable,state law.SolarCity provides you with a Performance Guarantee and Limited Warranty (the"Limited Warranty").The Limited Warranty is attached as Exhibit 2.SolarCity will also provide you with a System user manual entitled"Solar Operation and Maintenance Guide"(the"Guide"),that contains important operation,maintenance and service information.This is a legally binding agreement,so please read everything carefully including all of the exhibits. If you do not meet your contract obligations under this Lease,you may lose your rights to the System. If you have any questions regarding this Lease,please ask your SolarCity sales consultant. THIS AGREEMENT SUPERSEDES ALL PRIOR EXISTING CONTRACTS BETWEEN YOU AND SOLARCITY THAT PERTAIN TO THE"SYSTEM"DEFINED IN THIS AGREEMENT. 2. LEASE TERM SolarCity agrees to lease you the System for 20 years (240 full calendar months),plus,if the Interconnection Date is not on the first day of a calendar month,the number of days left in that partial calendar month, including the Interconnection Date.We refer to this period of time as the"Lease Term."The Lease Term begins on the Interconnection Date.The Interconnection Date is the date that the System is turned on and generating power. SolarCity will notify you by email when your System is ready to be turned on. SolarLease Agreement,version 7.1.3,February 15,2016 1620164 ❑ . ■ • ,Vy ANY 'ram" l yy ®TMER AUTHOMATION . .fob ED: vz(D�75 1 =bjedbuoy =eorju �m►py � -�?�tt�n5'1�' 1 g ---� _ .tv atas my ma MM=ralwva to work �. MW signed Sbmtm Of p � r Fa iNf1i-.1.Z r um Ma%pms. YJr.-- � • > ����,� _ ��al'"'stiae�iN�t s.•��es rs'�t'�t,�r►�^�7�w s.+r�.-u"' ' Vastaeflusells D eawmas"0f Pubt.c 9&fry SO&M of Awltt+n0 RrtgiA&tray& isna 51&rw td*- :.toms CS-1108615 JASON PATRY a ni STEWART DRI Abington KA 02351 � ;d.,.......wr.., 02MMO19 +-- Ofike of Commer Attain&Qoeium R auetlon HOME MPROVEMENT CONTRACTOR r w RegiaMation: 1OW2 TgPmryry� Expir&ti0n: 3Rirl017 Su➢ptemoM C SOLAR CRY CORPORATION JASON PATRY 24 ST MARTIN STREET OLD 2UNI AAksOROUGK MA 01752 UoQeeneeetorp The Commonwealth ofMassackwetts Department of Ind ustr[al Accidents I Congress Street,Suite 100 Bostan,MA 02114--2017 qp www.mass.gov/din Workers'Compensation lesuraace elllidmrit:Builders/CentraetordEleetrieiaasMumbers. TO BE r+ILED WITH THE PERMITTING AUTHORITY. Apnticsnt IntFnrntatiota Please Print Ia�ft. Nitrite(I3usinclOrgaaizafionitndividuat): SoIarCity Corporation Address: 3055 Cfearview Way City/State/Zip: San Mateo,CA 94402 phone#: (888)765-2489 Are you 2a r:mployes9 Cheek the xpprapriate box: Type of project(required): `- 1.©1 am a anfty With J5,QQ(Zemploycas(rill l audlor part-lime).' 7. ❑New construction 7-[]1 inn amle pmprietoror partnership and have no cmpleyas tvod-iug for arc in $, Remodeling any capacity.[No wwkea'comp.insurance req%dred.] 3.[J1 am a honneownerdoitall work mpsdr.lNov;orkers'comp,insurance r©quircd]► 9. [:]Dernol'etion 4.[J I am a homeowner and will be hieing contractors to coaducl all work on any property. t will 10 Q Building addition exam that all rkxnttucrors Wft have xart;rets'ctnnpensatiun insurance or are sole 11.0 Electrical repairs or additions ptopridors with no engrtoyees 12.Q Plumbing repairs of additions So I mn a gemai,cosnmlor and I hwe himil the sari-contractors listed on the attached sheet These utters haveemployecs arks have workers'comp,a.suraaao+ 1 I4.❑Roof.❑f Other solar panels repairs ti.IJ We are a ooMon pion and ita ofFtoers hate cuecised their right of excatption per MOE.c. 13Z§1(4) and we tmve soempicyms.[No vvorlcers'eonip.insurance required.] +My appticaat that checks box�l mast rdso rill out the-motion below showing their workers'compeaotion policy infornmtion. l lomeoWMS,,Vho submit this attidava indicating they are doing all wort:and then hire outside,corsractors min s*nit a nVW attidarit indicating sucllt koatrwwa that check this box mum attartard an arlelitionat sheet showing the moan of rim sub-cotnttadors and state whether or not thane entities have employc es. If the sub-eonmtMu bare anptoyccs,they mast rorhte their workers'tromp.policy mrntber. !am an employer titan as providing tworlirers'Compensation it{srrrattre for my earploy= Below is t/te paiicy and job site inforn"att: Insurance Company Name:American Zurich Insurance Company � Policy#or Self-iris.Lim#: WC0182015-00 Expiration Date: 911/2016 ' Jab Site Address: 402 Phinney's Lane ' City/StatefLipCenterville,MA 02632 Attach a copy of the workers'compeosatioti policy declaration page(showing the poft number and expiration date Failure to sccure coverage as required under MGL c.152,§25A is a criminal violation punislutble by a fine up to S 1,500.00 and/or one-year ar imprisonment,as well as civil penalties in the form of STOP WORK ORDER and a fine of rap to S250.00 a day against The violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cerft under the pains and penalties of perjury drat the Informatwir provided above Is true and c'arred. (Jason Patr March 8 2016 Phone Q91clal use only. Do not write in this wrA to be completed by elty or town o,Q7elaL City or Town: Permit/License# Issuing Apthority($M110 one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical inspector S Plumbing inspector 6.Other Contact Person: Phone#: - DATe(MMmDmmrl CERTIFICATE OF LIABILITY INSURANCE 0811712015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the poticy(las)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an enclorsernent. A statement on this certificate does not confer rights to the certificate haider In Bau of such endorsernent(s). PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES NWF —...._..._...._....._....... ............�F T_ 346 CALIFORNIA STREET,SUITE 1300 CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 AOpIrES .......... ...... ...................-...—.—. _-...__.._ Aft ShalU1D11 Scott 415-743-8334 -._._....... _.........._1N9URER[S)AFFORDINOCOV,ERAOE_.. 995301•STND-GAWUE-15.16 INSURER A;Zurich American Insurance Company 116536 W 51JI a INSURER R.NIA NIA SolalCetyCuxpolalion ..... .......................... ._. ........_....... ....... .. .__._ ' 3065 CIex*w way INsuRER c:NA to 1NsuRER D:American Zulich Insurance Company 40142 rrsuRER E INWRER F• COVERAGES CERTIFICATE NUMBER: SFl+-002713835-08 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR�_ rADDLTSUBR POLICY EFF POLICY EXP I, y TYPE OF INSURANCE l ibm vwun POLICY NUMB6t (WADOMMI IMMIDEVYYYY1 LIMITS A X 'COMMERCIAL GENERAL LIABILITY GL00182016-00 09R}1l2015 100112D16 EACH OCCURRENCE $ 3,W0.W0 _.._.. DAA�AGE 70 REPITED i CLAIMS.6'tADE n OCCUR � rR,EMISE$-,(Ea,Qlxurrence,} S- 00. 3,000,D X SR$250.00D ', I _ME D EXP(Anp one.person) S.. 5. 0 PERSONAL&ADV INJURY $ _._ 3,600,CM GEPrL AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE S 6 000,000 X PRO POLICY JECT �..... LOG t-t PRODUCTS-00w6 Iq AGG S-.. _.-__•.- 6_000_000 OTHER. f 3 A AIuTomDaiueLIABILITY SAP0162D17--00 09JOIr 15 09,01/M16 COMBMIED SINGLE UNIT S 5,OD0�0 �Ee ecaderril .....-_....... X_ ANY AUTO I BODILY INJURY(Per person) S X ALL OWNED X SCHEDULED BODILY INJURY(Per accident) S X HIRED AUTOS ,x AUTOSUTOS NON-OA+NED I f i - �ePROPERDAMAGE•' S COMPICOLL DED: 3 $5,0w UMBRELLA LfAB I OCCUR I EACH OCCURRENCE $EXCE66LIAO CLAIMS-MADE i - AGGREGATE S OW i RETENTIONS S O WORKERS COMPE&SAYION jWC0182014-00(AOS) 0011RDI5 109/0112016 X I PER o H• AND EMPLOYHRS'LIABILITY l.OTATL _ .-..�R_.. A ANY PROPRIETOR PARTNERJE FCUTIVE YIN WCA162015-0D{MA) 0901r1015 i09,10112016 E.L.EACH ACCIDENT S 1,000,000 4FFZER4WM9ER EXCLUDED? Q H!AI (Mandatory In NH) WC i OUCTIBLE S5W 600 E L.DISEASE.EAEMPLOYEE S 1,00D,000 q yea describe under `DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT S 1,00D,000 t DESCIMM OF OPERATIONS I LOCATIONS I VERCLES IACORO 1101,Additional Remarks Schedule,.may he atraahod If mere space to requlredl Evidence of in surance. CERTIFICATE HOLDER CANCELLATION Sdar(Ay CorporeOon SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCIELLED BEFORE 3055Cleantiee Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELNERED IN Sm Wtoo.CA 9NO2 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE at Marsh Risk&Insurance Services Charles Mannolejo 01988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD Version#54.9-TBD ,SolarCit Y March 7, 2016 RE: CERTIFICATION LETTER Project/Job #0262751 Project Address: Cofran Residence 402 Phinneys Lane Centerville, MA 02632 AHJ Barnstable SC Office Cape Cod Design Criteria: -Applicable Codes= MA Res.Code, 8th Edition,ASCE 7-05, and 2005 NDS - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground Snow Load = 30 psf - MP1A: Roof DL= 10.5 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL= 11.7 psf(PV Areas) - MPiB: Roof DL= 13.5 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL= 11.7 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.19069 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure 4irectly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/dots submitted for approval. 2� K. U' IUKI Digitally signed by Humphrey � ST UCTURAL .51933 Sincerely, Ka rl u ICI -0 F "�,�� cisTE�` Humphrey Kariuki,P.E. Date: 2016.03.07 20:37:37 -05'001 Professional Engineer T: 443.451.3515 email: hkariuki@solarcity.com W55 Clearview Way San Mateo,CA 94402 T(650) 638-1028 (988)SOL CITY F(650)6N 1029 solardty.com M sm` Version#54.9-TBD o''SolarCit o „� y HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing _ X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPiA 64" 24" 39" NA Staggered 68.8% MPIS 64" 24" 39" NA Staggered 68.8% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X=X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1A 48" 19" 65" NA Staggered 85.8% Mp1B 48" 19" 65" NA Staggered 85.8% Structure Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MP1A Stick Frame @ 16 in.O.C. 370 Member Impact Check OK MPiB Finished Attic @ 16 in.O.C. 370 Member Impact Check OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clearview Way San Mateo.CA 94402 1(650) 638 -1028 (888)SOL-CITY a(650)638-1029 solarciity.com V STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP1A Member Properties Summary MP1A Horizontal Member Spans Rafter Pro erties Overhang 0.82 ft Actual W 1.50" Roof System Properties San 1` 11.78 ft Actual D Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofin 'Material a°s}, ,'Comp Roof San 3 A.:, 4 . 10.88'in.^2 = Re-Roof No San 4 S. 13.14 in.^3 PI ood Sheathing w ._� Yes, .- San 5 I : . 47.63 in.^4,. Board Sheathing None Total Rake Span 15.78 ft TL Defl'n Limit 120 Vaulted Ceiling u a : " No . PV 1 Start 0.83 ft - y $Wood Species ~ SPF Ceilin Finish 1/2"Gypsum Board PV 1 End 14.08 ft Wood Grade #2 Rafter Slope 370, PV 2 Start Fe 875ipsi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi A To Lat Bracing;." ", _ - Full"° PV 3 Start _ E Y-'1400000 psi> Bot Lat Bracing At Supports PV 3 End Emig 510000 psi Member Loading Summary Roof Pitch 9 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.5 psf x 1.25 13.1 psf 13.1 psf PV;Dead Load M„, _ z' PV-DL 3.0 psf, x 1.25 a . 3.8 psf Roof Live Load RLL 20.0 psf x 0.75 15.0 psf Live/Snow Load' . ;; n,a M :; --LL SLI,Z- - 30.0 psf p x 0.7 1'x 0.39 21:0 psf. 11.7 psf: . Total Load(Governing LC I TL 1 34.1 psf 28.6 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf= 0.7(Ce)(CO(IS)pg; Ce=0.9,Ct=1.1,I,=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CIF Cr D+ S 1.15 1.00 0.41 1 1.2 1.15. Member Anal sis Results Summary Governing Analysis Pre-PV Demand JPost-PVDemandJ Net Im act Result Gravity Loading Check 715 psi 593 psi 0.83 Pass ' w [CALCULATION_OF DESIGN=WIND=LOADS -MP1A 1 -- 4. Mounting Plane Information Roofing Material Comp Roof SolarCity SleekMount N. ., � PV S stem�T, e TM Spanning Vents No Standoff Attachment Hardware Comp Mount Type C' Roof Slope 370 Rafter Spacing -- --._-- - 16"O.C. . ,. Framing Type Direction Y-Y Rafters Purlin-S acing X-X Purlins Only -__ — - NA Sp q _ Tile Reveal y Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA " r ffi Standin Seam ra Spacing SM Seam O-n NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method _ Partially/Full yY Enclosed Method Basic Wind Speed V 110 mph Fig. 6-1 Exposure.Category C :- �'.:' -;:Section 6 5.6.-3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Me noof Height- jT-7 1 15 ft '77-71 Section'6.2". Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 _ Table 6-3 Toraphic Factor Krt 1.00 . = _ Section 6:5.7 pog Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Tabie 6-1 . .: Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 22.4 pslf Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC Dow i A.88 . �,-'"x ` Fig:6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC) Equation 6-22 Wind Pressure U -21.3 psf Wind Pressure Down 19.6 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowablee.Cantilever 7---Landscape 24' NA . Standoff Configuration Landscape Staggered Max Standoff Tributery. a Area Trib 17 sf - - PV Assembly Dead Load W-PV 3.0 psf Net Wind.Uplift at Standoff Thactual - =344 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 68.8%_ X-Direction Y-Direction Max Allowable Standoff Spacing_ Portrait 48" 65" Max Allowable Cantilever _Portrait 19' Standoff Configuration Portrait Staggered Max_SSWndoff_TribuWry Area- Trib PV Assembly Dead Load W-PV 3.0 psf Net_Wind Uplift at Standoff t T-actual__ _ 4291bs Uplift Capacity of Standoff T-allow 500 Ibs Stanan ff.Demand Ca aci DCR 85.8% I . v , 1 STRUCTURE ANALYSIS -;- LOADING SUMMARY AND MEMBER CHECK- MP113 Member Properties Summary MPIB Horizontal Member Spans Rafter Pro erties Overhang 0.82 ft Actual W 1.501, Roof S ystem Properties S ami s 11:78 ft" :.. Actual D, ,, A 7:25' #t Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofing Material° t R, .,, Comp Roof ;, , Span 3. „ h A. _ ^2 10:88 in Re-Roof No Span 4 S. 13.14 in.^3 PI wood Sheathing, "w` i . ,, ' ;`° ' Yes,_ {• s ,Span 5 I Board Sheathing None Total Rake Span 15.78 ft TL Defl'n Limit 120 Vaulted.Ceiling, V Yes- PV i Start '0.83 ft'- . . Wood S ecies:_ - ,SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 14.08 ft Wood Grade #2 Rafter Slope -0 , _ c '37° PV.2 Start F -Fb4 Rafters acin 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing e" g Full ; . PV 3 Start ' w ''E ' 1400000 sip i_� `.� . Bot Lat Bracing Full PV 3 End Emi„ 510000 psi Member Loading mary Roof Pitch 9 12 Initial Pitch Ad'ust Non-PV Areas PV Areas Roof Dead Load DL 13.5 psf x 1.25 16.9 psf 16.9 psf PV Dead Load', t r" PV-DL' 3.0; sf " x 1.25 1,v« 18 psf Roof Live Load RLL 20.0 psf x 0.75 15.0 psf Live/Snow Load '`_ . '` " ; LL SOI 30.0 psf x 0.7 1 x 0:39, £ '2110'sf. _ n > > 11.7 psf Total Load(Governing LC TL 37.9 psf 32.4 psf Notes: 1, ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf= 0.7(Ce)(C0(IS)pg; Ce=0.9,Ct=1.1, IS=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CF Cr D+ S 1.15 1.00 1 1.00 1 1.2 1.15 Member Anal sis Results Summary Governing Analysis I Pre-PV Demand I Post-PV Demand Net Impact Result Gravity Loading Check 794 psi 671 psi 0.85 Pass N CALCULATION OF DESIGN WIND_LOADS=MPIB _-_- Mounting Plane Information Roofing Material Comp Roof P_V System Type SolarCitySleekMountik _ - -- — Spanning Vents No Standoff Attachment Hardware Comp Mount Type G '- u Roof Slope 370 Rafter Spacing - - - 16"O.C. Framing Type Direction Y-Y Rafters Purlin Spacing- X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standing Seam/Trap S acin SM Seam On NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method -_ _ _Partially/Fully EnclosedrMethod Basic Wind dSSpeed V 110 mph Fig 6 1 Exposure.Category � _ - C Section 6 5._6.3. - Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height _ - < . h £15 ft = - _ Section 6T_7 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 K 1.00 _ Section 6.5.77 Topographic Factor ' � _- �_ _ rt� Wind Directionality Factor Kd 0.85 Table 6-4 importance Factor- s �-..-.j _ " 1.0 Table 6-1 Velocity Pressure 4h qh =0.00256(Kz)(Kzt)(Kd)(V-2)(I) Equation 6-15 22.4 psf Wind Pressure Ext. Pressure Coefficient U GC u -0.95 Fig.6-11B/C/D-14A/B Ed. Pressure Coefficient Down GC Down 0.88 . ; o e ¢ '°" Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC) Equation 6-22 Wind Pressure U -21.3 psf Wind Pressure Down 19.6 psf ress e ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscapes 24" ' a Standoff Configuration Landscape Staggered Maz_Standoff Tributary Area Trib ,_ . 17 sf" - PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff_ _ -- T=actual Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand Ca aci = DCR 68.80/o X-Direction Y-Direction Max Allowable Standoff Spacing_- Portrait 48" 65 Max,Allowable Cantileverantilever _ __ _Portrait 19"" * �< _ :: NA_ Standoff Confi uration Portrait Staggered Max Standoff Tributary Area P Trib 1122_sf PV Assembly Dead Load W-PV 3.0 psf NetNet Wind.Uplift at Standoff_ Tactual "7429 Ibs Uplift Capacity of Standoff T-allow 500 Ibs � � Standoff Demand Ca aci R DCR `85.8% '`m Assessor's map an &� ....:.. ..;. ...�� ' SYSTEM MUST S� �oF THE roe SEPTIC Q Sewage Permit number .......� .�.g 41•••..���: C, NSTAL E IN COMPLIANC p E ` WIT1�TITLE C i� = 1 5 BABB$TdDLE. � House number ..................:....i .................r:....:......... .. ENVIRONMENTAL' CODE 900 o639-. T REGULATIONSNPy TOWN, OF BARN ABLE BUILD ' G INS'PECTOR APPLICATION,FOR PERMIT TO A P� .......................... TYPE OF CONSTRUCTION ................:5�...... ....../7.- ..T 2..e................................... ................................. L cc// ........ ... ....T..............19. . 0.0 TO THE INSPECTOR OF BUILDINGS: The undersigned here y applies fora ermit according to the followi inform tion: �- Location .. ...........0.6. . / �!1.�... ./�J.l......... � r�l41. K........................ ProposedUse �1.;.>7._IC..... ...... . ... ..... . ............................................. ...................................................... / .Fire District ....... ...Zoning District ...f ^.1............................ . .......................... ��----�� / Name of Owner . f!., r .r..Address ... �. e....66-k .. �1 .. .. `z... fl(J�A Nameof Builder ...........I rn...............................Address .................................................................................... Nameof Architect ..................................................................Address ............. ................. ..�.. ................................................ Number of Rooms ..... �................................... ...................Foundation .../ Q ...� � .t� (.J C off? Exierior / ....../. Roofing . ...... ... / ' � C v CC� V `� ..................Interior .........6 t.Floors .... . ...... . .. ... C.�................................. \ Heating . .......Plumbing.......... Fireplace �� .�o........................................................Approximate Cost .... P:20-0............................. Definitive Plan Approved by Planning Board ---------- _ ___ _____19_ Area .......................................... Diagram of Lot and Building with Dimensions Fee �7j. SUBJECT TO APPROVAL OF BOARD OF HEALTH - o a 7 7.�- OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Name .... .. ........ r. ......................... .Q.��. , .`r7 Construction' Supervisor's License . . .. .......... a n- --- --- ' ' ` - w - ^ - Y PREENBRIER CORP. ^n 28531 lz to Nd------.. Permit for --..�—S--ry---- ` . ~ Single Family Dwelling ' ------------------'~—'-----'' _ Location ---L«t..3.6.�_.�.O2..Bz '.�_�u�e � _ Centerville ----------.. — ...' ..—......... �.-------. ' \ ' -Owner —�reeobrier 'Co � '— --' ^ ~ ' Type of Construction ---��ame...................... -^--------------^--'^-------- Plot ............................ �� -----'------' ' October ll ' 85 Permit Granted -------.�--�---]V ' . � . Dote of Inspection,—.0c.t�be�—ll�--/l`g 85, Dote Completed ~ - jr . �. . ^ � � M � ~ - ~ ' ; -- . o 7�1 qq tZ % S wipry. s 0 c � 0 r-- T � O T L osPop ' CERTIFIED PLOT PLAN ` o RgBEFlT. .�� L o T 3h /777.7 ELDt ED E . 193 --._. No 67 $ N V Y LAB - ' ;r SCALE_ / =y,, ' DATE �= r J! 2Eld�l/E2 0 L)GE' E1VgBNRING Imo.l!� 1 CERTIFY THAT THE ' 'CLIENT.- .. SHOWN ON THIS PLAN IS LOCATED EGISTER.E® RE®iSTIaREO x" 930 ON THE GROUND A3 INDICATED AND CIVIL LAND' 40,9 No"',,. CONFORMS TO THE ZONING LAWS ENGINEER SURVEYOR OR„�Y,, OF ,O��i✓s��c'� fAAS3 <, . 712 MAIN ST: xr C$1.BYl HYANNIS,;MASS. ---- ---- :s SKEET/'OF / DA E REG. LAND SURVEYOR I • 311 P F 2Eo ' lI 1 S ,I , (� P, ILL{ 24 l �� q � o �� a l9 1� Ay� I VN t1 , ' ; Ask E _; d L.o T 5 F , .iv1or.,� 2o,S34 T�uT C7-/orl / S� S LOT" J -;t- .i LEGEND EXISTINS SPOT ELEVATION Ox0 -"EXISTING CONTOUR --- 0 -- CERTIFIED PLOT PLAN FINISHED SPOT ELEVATION [� Lv -r s G Ptf fv��F: INISHEO CONTOUR 0 F`The location of any existing under .�, ound sewerage, wells; or' other utilities shown on this plan is approx IN maie.:onl as determined from records and/or verbal �� � 'anformation. .The contractor is responsible for the S�1, �y S�7�1"� !. � ASS* b ,verification of the existing locations in the field`. SCALE, / 4-0 DATE at,,/ zsJ'�s DREDGE ENGINEERING CaIN Q,�� N ;R� ,� CLIENT...___,_._ I CERTIFY THAT THE PROPOSED ; r . EGISTERE REGISTERED JOS NO. ? �9` / BUILDING SHOWN ON THIS. PLAN CIVIL LAND A A A4 CONFORMS TO THE ZONING LAWS ' DR 9Y _�...=____ O F B A R N S TA 8 L E M ASS , ) 712 M.A I N STREET. CN- SY HYANNIS* MASS. SHEET—L. OF E REG. LAND SURVEYOR .j 4 3 P TOWN OF BARNSTASLB er """"'mit No. 28531 ----------------------------- _ Building Inspector Cash KUa OCCUPANCY PERMIT.-,.- -� Bond ---------------�--- Issued to Greenbrier Corp. Address lot #36 402 Phinney's Lane, Centerville Wiring Inspector � � �� � Inspection date Plumbing Inspector` ,xf, Inspection date Gas Inspector Inspection date.� � �- ✓ Engineering Department `� ,f- X `` Inspection date fly. rf^ ,Board of Health -Gi'YViVt.QIJ Inspection date J y, . THIS PERMIT WILL NOT BE VALID, AND THE BUILDING SHALL NOT BE OCCUPIED UNTIL SIGNED BY THE BUILDING INSPECTOR UPON .SATISFACTORY COMPLIANCE WITH TOWN REQUIREMENTS AND IN ACCORDANCE WITH SECTION 119.0 OF THE MASSACHUSETTS STATE BUILDING CODE. Building Inspector r . ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES . ' A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED°VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS_. - CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING k DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT I1471Y ` EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING. 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN :POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE .' GALV GALVANIZED HAZARDS PER ART. 690.17. . GEC .GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED' •Y ` HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. ' I CURRENT 6. CIRCUITS OVER 250V TO GROUND_ SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B): I' M Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE ' . BUILDING OR ARE RUN IN METALLIC RACEWAYS OR R kW KILOWATT F ENCLOSURES. TO THE FIRST.ACCESSIBLE DC. '. t LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690,31(E). MIN MINIMUM- . 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW• RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY t r a NEUT NEUTRAL. UL LISTING. y NTS NOT TO.SCALE 9. MODULE .FRAMES SHALL BE GROUNDED AT THE OG ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL ' PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE. SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. a - . S STAINLESS STEEL t - � STC STANDARD TESTING CONDITIONS TYP TYPICAL , UPS "UNINTERRUPTIBLE POWER SUPPLY r r V - VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc ' VOLTAGE AT OPEN CIRCUIT W WATT - 3R NEMA 31R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS . PV4 , UPLIFT.CALCULATIONS PV5 _THREE LINE DIAGRAM LICENSE GENERAL NOTES cutsheets Attached 1. ALL WORK TO BE DONE TO THE 8TH EDITION GEN #168572 ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH,.THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. 4 I • r MODULE GROUNDING METHOD: ZEP SOLAR j - _ REV BY DATE COMMENTS' AHJ: Barnstable REV A NAME DATE COMMENTS AD r x r UTILITY: NSTAR Electric (Commonwealth Electric) . • _ • � � � 11 � All, CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-0 2 6 2 7 5.1 O O = la CASSIDY COFRAN Cassidy Cofran RESIDENCE Ryan waszok BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: J �j�-SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 402 PHINNEYS LANE 7.65 KW PV ARRAY r PART TO OTHERS OUTSIDE THE RECIPIENTS MDD�I,� CENTERVILLE MA 02632 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-255PD05.18 24 St.Martin Drive, Building 2, Unit 11 PACE NAME: SHEET: REV DATE: Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650).638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A—US000SNR2 COVER SHEET PV 3/7/2016 (888)-SOL-CITY(765-2489) www.splarcitycom' PITCH: 37 ARRAY PITCH:37 MP1 AZIMUTH:257 ARRAY AZIMUTH:257 MATERIAL: Comp Shingle STORY: 1 Story P IF N 0 RIUKI (E) DRIVEWAY ST UCTURAL `CD v 140.51933 r �FGISTE�� Q STAMPED & SIGNED FOR STRUCTURAL ONLY ❑ Digitally signed by A _ Humphrey Kariuki 3 Date: 2016.03.07 20:37:55 D ❑ LEGEND , -05'00' "(E) UTILITY METER & WARNING LABEL ❑ m� INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC STRUCTU DC DISCONNECT &, WARNING LABELS - - - - - ° CHANGE ❑ AC DISCONNECT & WARNING LABELS Front Of House o DC JUNCTION/COMBINER BOX & LABELS El O° DISTRIBUTION .PANEL & LABELS O Lc LOAD CENTER & WARNING LABELS STRUCTURE B CHANGE O DEDICATED PV SYSTEM METER O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR 3 --- CONDUIT RUN ON INTERIOR GATE/FENCE W O . O HEAT PRODUCING VENTS ARE RED r,, `l INTERIOR EQUIPMENT IS DASHED M O AC �nV SITE PLAN N O Scale: 1/8" = 1' W 01' 8' 16' E S CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT USED FOR THE J B-0262751 00 ��� CASSIDY COFRAN Cassidy Cofran .RESIDENCE Ryan WOszak 1 I,`�O'ar�l�" BENEFIT OF ANYONE EXCEPT SOLARgTY INC., MOUNTING SYSTEM: �.�; y® TS NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMt T C 402 PHINNEYS LANE 7.65 KW PV ARRAY PART TO OTHERS OUDE THE RECIPIENT'S oun e T ORGANIZATION. EXCEPT IN CONNECTION WITH MODULES- CENTERVILLE, MA 02632 THE SALE AND USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-255PD05.18 2a s1. Martin Dreg.Bufld01 2 Unit n SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV DATE Marlborough,MA 01752 PERMISSION OF SMENT, I INC. INVERTER T: (650)638-1028 F. (650)638-1029 SOLAREDGE SE6000A—USOOOSNR2 SITE PLAN PV 2 3/7/2016 (BBBI-SOL—CITY(765-2489) www.solarcity.com (E) COLLAR TIE (E) KNEE WALL $1 S1 4" - 4" 0 11'-9" 0 11'-9 (E) LBW : . (E) LBW , S A SIDE VIEW OF MP1A NTs B IDE VIEW OF MP1B NTS MP1A X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES µ MPiB X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED _ LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 19„ _ PORTRAIT 48 , • RAFTER 2X8 @ 16"OC ROOF AZI 257 PITCH- 37 •STORIES: 1 1. ARRAY AZI 257 PITCH 37 RAFTER .2X8 @ 16"OC ROOF AZI 257 PITCH 37 STORIES: 1 ARRAY AZI 257 PITCH 37 C.I. 2X8 @16"OC "' Com Shingle C.J. 2X8 @16"OC Comp Shingle PV MODULE 5/16' BOLT WITH INSTALLATION ORDER t F• FENDER WASHERS = _ LOCATE RAFTER, MARK HOLE - �° K. ZEP LEVELING FOOT — `(1) LOCATION, AND DRILL PILOT o uKI g AL ZEP ARRAY SKIRT (6) HOLE. " s No;i933 r (4) (2) SEAL PILOT HOLE WITH �FcisrE�``� ZEP COMP MOUNT C POLYURETHANE SEALANT. SS�ONAt ZEP FLASHING C (3) STAMPED & SIGNED (3) INSERT FLASHING. (E) COMP. SHINGLE 4 PLACE ,MOUNT:° _ - FOR STRUCTURAL ONLY a (E) ROOF DECKING (2) NSTALL LAG BOLT WITH5/16" DIA STAINLESS (5) T(5) '-,) SEALING WASHER: z. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF I i ' CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: I 1 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE v B—O 6 7 I O O ���� ■ CASSIDY COFRAN Cassidy COfran RESIDENCE Ryan waszak - f SolarCit BENEFIT Of ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �hd NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 402 PHINNEYS LANE 7.65 KW PV. ARRAY rr y. PART TO OTHERS OUTSIDE THE RECIPIENrs Moou�s CENTERVILLE MA 02632 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St Martin Drive,Building 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-255PDO5.18 PAGE NAME SHEET- REV DATE artin Dive, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1028 F: (650)638-1029 ->PERMISSION of sotARarr INC. SOLAREDGE SE6000A—USOOOSNR2 STRUCTURAL VIEWS PV 3 3/7/2016 (868)-SOL—CITY(765-24B9) www.sdarcitY..com UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. f PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-0262751 00 CASSIDY COFRAN Cassidy Cofran RESIDENCE y SolarCity. CONTAINED SHALL NOT BE USED FOR 1HE R On WOSZOk .,BENEnT,OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 402 PHINNEYS LANE 7.65 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MooUtF CENTERVILLE MA 02632 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-255PD05.18 PAGE NAME SHEET: REY. DALE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F.- (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A-US0o0SNR2 UPLIFT CALCULATIONS PV 4 3/7/2016 (888)-SOL-CITY(765-2489) www.solarcitycom p GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE 9 IN V 1 -(1)SOLAREDGE SE6000A-USOOOSNR LABEL: A -00)TRINA'SOLAR - .TSM-255PDO5.18 GEN. 1 BOND (N) #8 GEC TO TWO (N) GROUND Panel Number. G2020M61100 Inv 1: DC Ungrounded ## ## # 68572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:43959233 Tie-In: Supply Side Connection Inverter; 600'OW,-240V, 97.574 w/Unifed Disco and ZB,RGM,AFCI PV Module; 255W, 232.2W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR ; Overhead Service Entrance INV 2 .` Voc:'38.1 Vpmdx: 30.5 INV 3 " Isc AND Imp,ARE SHOWN'IN THE DC STRINGS IDENTIFIER E) 100A MAIN SERVICE PANEL _ E100A 2P MAIN CIRCUIT BREAKER Inverter - (E) WIRING BRYANT CUTLER-HAMMER - 4 Load Center Disconnect 3 SOLAREDGE 1 DC+ - - 100A/2P SE6000A-USOOOSNR2 Dc_ MP 1. 1x15 A 35A/2P ------------ - ----------- --- ---- B ---------, ---------- -- •240V '- ^ A N r - EGC B L2 DC+ - (E) LOADS �` c �-- ---- GND - - - --- ------------ P GE?. --- DC C+ MP 1: ' - - - - -- ----- ------- ----- ------------- - --- --------- . r-- 1 Z - _ 7 1 NGND EGC G (1)Conduit Kit; 3/4' EMT a , • a' o EGC/GEC GEC _ _ - ' • _ - . .•' - JO 120/240V SINGLE PHASE UTILITY SERVICE r z - , 7• PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (2)Gro�gd Rod /� (1)BRYANT#BR24L70RP n \, (30)SOLAREDGE 4P300-2NA4AZS 5 B x 8, Per /� ' Load Center 70A 120/2a0V, NEMA 3R /"f1C _ " Y PowerBox Optimizer, 30OW, H4, DC to DC, ZEP DC -(2)ILSCO 44 IPC 4�0- 6 - -(1)CUTLER-HAMM #BR235 ' ` Insulofion Piercing Connector; Main 4/0-4, Tap 6-14 Breaker, 35A 2P, 2 Spaces nd (1)AWG #6, Solid Bare Copper S SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE 6 (1)CUTLER-HAMMER #DG222URB -(1)Ground Rod; 5/8' x 8% Copper l AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Disconnect; 60A, 24OVac,Non-Fusible, NEMA 3R -(1)cuTLER-IiAMMER oGlooNe (N) AR GROUN 6 .47(D)_ NOTE PER,EXCEPTIO NO.. ADDITIONAL Ground eutral. it; 60-100A General Duty(DG) 4 ELECTRODE MAY NOT BEREQUIRED DEPENDING ON:LOCATION OF (E) ELECTRODE g • .... .. - - •.� a '., _ - _ e • 1 AWG#6, THWN-2, Black 1 AWG$8 ; 2 AWG 0, PV.1Mre, 60OV, Black Voc* =500 VDC Isc =15` ADC O�OAWG O� O THWN-2, Black 4 1 �6, THWN-2, Red 3 (1)AWG d8, THWN-2, Red (1)AWG #6, Solid Bare Copper EGC Vmp =350 ' VDC Imp=10.79 ADC (1)AWG/6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (1)AWG#10, THWN-2, White NEUTRAL Vmp 240 VAC Imp 25 AAC # (1 Conduit Kit; 3/4°.EMT. , • , , , . ,• . . . . . . /6,,Solid Bare.Copper. GEC, • . (1)Condult.Kit;•3/47.EMT. . . _ , . , • • , • • • • . • •-(1)AWG •.TH,WN-2,•Green . .EGC/GEC-0)Conduit,Kit;•3/,r . . . ... . . . . . . • _ (2)AWG 010, PV Wire, 600V, Black Voc* =500 VDC Isc =15 ADC O (1)AWG 16, Solid Bare Copper EGC Vmp =350 VDC Imp-10,79 ADC (1)Conduit Kit;.3/4' EMT . . . . . . . . . . . . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: R �j 5 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE -0 O O CASSIDY- COFRAN - Cassidy Cofrari RESIDENCE Ryan waszak BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .�'c SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Corn Mount T e C 402 PHINNEYS LANE? 1 :�. m 7.65- KW PV -ARRAY �r PART IZ OTHERS OUTSIDE THE RECIPIENTS MODULES CENTERVILLE MA 02632 r ORGANIZATION, EXCEPT IN CONNECTION WITH , Unit 11,2 ' THE SALE AND USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-255PDO5.18 SHEET: REV DATE Marlborough, MA 24 Si.Martin Drive, Building ing SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME PERMISSION OF SOLARCITY INC. 01752 INVERTER. T; (650)638-1028 P (650)638-1029' SOLAREDGE SE6000A-USOOOSNR2 .. THREE LINE DIAGRAM PV 5 3/7/2016 (868)-sa_CITY(76s-2489) www.eolarcity.aam 1�• 0 0 0 -o o - Label Location: Label Location: Label Location: (C)(CB) e (AC)(POI) (DC)(INV) Per Code: _ o "— Per Code: . ,o �_D Per Code: ` NEC 690.31.G.3 Do 0 0 NEC 690.17.E D •o 'D o- o NEC 690.35(F) Label Location: - o :o • D o 0 0` • , TO BE USED WHEN (DC)(INV) o•D D - D _r; -o D D • D ;; INVERTER IS p O Per Code: -o o - D UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: o 0 0 -o ` �, (POI) • -o (DC) (INV) _' Per Code: _ Per Code: •-D ;D o 0 o NEC 690.17.4; NEC 690.54 • -OW NEC 690.53 :o D o•D D • 1 �• - D o- o-- Label Location: ° (DC) (INV) Per Code: - o • 0•-D 0 0 D NEC 690.5(C) o- .0 D D Label Location: o D 0- z (POI) -o D D • D D D • -o o Per Code: oe D o -o NEC 690.64.B.4 Label Location: e (DC) (CB) MZD Per Code: Label Location: D o o e NEC 690.17(4) Q (D) (POI) • o :o D Per Code: o•D D D o 0 0 -. NEC 690.64.B.4 e _ O OD i - Label Location: to (POI) Per Code: Label Location: o ° o `: NEC 690.64.B.7 (AC) (POI) ,` o 0 0 0 (AC): AC Disconnect Per Code: °0 - (C): Conduit NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect Label Location: (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect • (AC)(POI) (LC): Load Center Per Code: (M): Utility Meter �ry NEC 690.54 (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR ��r�,� 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR MALL IT BE DISCLOSED �- San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE 'ChO'��I� (888)-SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF.SOLARCITY INC. . o f .. __7 .. ` ^SoiarCity- I ®pSolar- Next-Level PV Mounting Technology _. f-- ^SOiarCity ®pSolar - - _ _ _ Next-Level PV Mounting Technology Components Zep System for composition shingle roofs i Leveling h t rig Fo ot L Ground Zep - Interlock p(-y Side sia—) l eveung Foot r 172 ETL listed t U 4 Part o850 1 L 467 - -. Zep compatible PV Module ,•_. -- " - - - r . .. . .- _ � " _ Zep Grove _ ,'. '�` : - - •,- :a? __ - _ y •- Roo4 Attachment - LL_ fey - Comp Mount Ar Skirt •.• .. ." - .4 .. .. i Part No.850-1382 f' Listed to UL 2582 , .. - Mounting Block Listed to UL 2703 Description- • - PV mounting solution for composition shingle roofs , FIN. — 0 Works with all Zep Compatible Modules A ' .MMPpSw Auto bonding UL-listed hardware creates structural and electrical bond - Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from -•. . _ any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2` DC Wire Clip .' �L LISTED' _ Specifications Part No.850 1388 Part No.850-1511 Part No.850 1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 Designed for pitched roofs • Installs in portrait and landscape orientations Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703.. - • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 ° lkhbm�. • .Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain ' Array Skirt,Grip, End Caps t Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for, This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for - each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely p .each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely - responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. - responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A - - , Date last exported: November 13,2015 2 23 PM t Document#800-1890-001 Rev A - Date last exported: November 13,2015 2:23 PM ' solar=co rulA Solar=qqSolarEdge Power Optimizer �n Module Add-On for North America O P300 / P350 / P400 SolarEdge Power Optimizer P30e P35D P400 (for Module Add-On For North America . -� 60-cell PV (for 72-cell PV (for 96-cell PV modules) modules) modules) P300 / P350 / P400 a INPUT' I Rated Input DC Powers 3010 350 400 W - Absolute Maximum Input Voltage(Voc a[lowest temperature) 48 60 80 ... Vdc.... . _MPPT Operating Range............................................. 8 48 ....860.....................8:.$Q......... .... Vdc..... Maximum Short Grcwt Current(Isc) 10 .Adc ..... ....... ........ .. .................................. .......................... ................ ........ ..................... 'nano^' Maximum DC Input Current 12.5 Adc 1� - ............................... .......................................................................................................... .. .. .... Maximum Efficiency 99;5 % ......................... `.ti .. Weighted Efficiency 98.8 ...%.... ............. - Overvoltage Category II .OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current .............................15: Adc ... Maximum Output Voltage 60 Vdc "IL .OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF). t� Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC63000-6-2,IEC63000-6-3 1...................................................................................................................................................... ... Safety ......IEC62109-1(class II safety.),UL3741............... ...... ... ............................................................ ............ z '��� RoHS Yes '- .. - 5 INSTALLATION SPECIFICATIONS ' Maximum Allowed System Voltage 1000 Vd[ r ..negs ..................................................................................141x............S/S...................... ....... ... ... n Dimensions(W zLx H) - 141x212x40.5/S.SSx8.34x1.59 mm/.. _ ' Welght(including cables) 2.1 ' - Input Connector MC4/Amphenol/Tyco .... .................................. ......................................... + - Output Wue Type/Connector Double Insulated Amphenol - '` - ............. .. ......................................................................I................. O 0.95/3.0 .................................................................................... . 1239........................ ...m.../.k. .... Operating Temperature Range....................................... .............................46+85/.40 +185 ..... •C/•F ....... .............. ... ..... Protection Rating IP65/NEMA4 Relative Humidny 0 100 % ........................... .. ....... .. x.r.e src po,.�,or m.m 11 M-11 If„pmsx oowcr io�a.«.w.ra �- )PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE y INVERTER 209V 480V 1 PV power optimization at the module-level Minimum String Length(Power Optimizers) B 10 18 - ................................................................................................................................................................... Up to 25%more energy - Maximum String Length(Power Optimizers) 25 25 50 ......................................................................................................................................................................... Maximum Power per String 5250 6000 12750 W — Superior efficient 99.5% .. ............................................................................................................................................................................. P efficiency 1 . . - Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading - Parallel strings of Different Lengths o.Orientations ves — Flexible system design for maximum space utilization , — Fast installation with a single bolt — Next generation maintenance with module-level monitoring - e - - - Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA WWW.50)aredge.u5 t ~ THE Timamount. MODULE TSM-PD05.18 Mono Multi Solutions 1, - . - DIMENSIONS OF PV MODULE '. ELECTRICAL DATA @ STC - unit:mm t 3 Peak Power Watts-Pm (Wp) T 245 250 255 250 O 941. ' 1 ;Power Output Tolerance-PMnz(%) 0-+3 , Maximum Power Voltage-VMP(V) i 29.9 1 30.3 { 30.5 _r 30-6 -THE UNROE-- m- Ount I Nn eru, Maximum Power Current-ImPP(A) 8.20 827 8.37 8.50 [' 1 E j Open Circuit Voltage-Voc(V) � 37.8 - � 38.0 I 38.1 38.2 ' - wnnu HCHae i- Short Circuit Current-Isc(A) 8.75 8.79 8.88 9.00 , Module E _ 15.6 - -. c l �_' - � 1.,..__.._..r,.,fFlclen�cY rlm(%) 15.0 15.3 �.�,r_.15�9 �. . - - Y - ,, - C Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1.5accordih.to EN 60904-3: MODULE 5T } • !. 'Typical efficiency reduction of 4.5%at 200 W/m2 according to EN 60904-I.• ,,+ . * 1t ' I ELECTRICAL DATA @ NOCT ® /�ELL _ - - .. _ S Maximum Power-Prom(Wp) j- 182 f(v - 186 �90 y l� 193 . -�Maximum Power Voltage-VMP(V) 27.6 28.0 28.1 28.3 { MUITICRYSTALLINE MODULE ' Maximum Power Current-l-P(A) 6.59 I 6.65 6.74 6.84 6003 GROUNDING HOLE r ' t A A Open Circuit Voltage(V)-Voc(V) 35.1 35.2 - 35.3 35-4 �. WITH TRINAMOUNT FRAME t I .,� Short Circuit Current(A)-isc(A) 7.07 7.10 7.17 7.27 No.-Irradiance at 800 W/m-.Ambient Temperature 20°C,Wind Speed I m/s. - - - a PD05.18 812 180 ff 245 260W -� � � � Back View ` - • - _ MECHANICAL POWER OUTPUT RANGE _ � - - N_ - _DATA __ _ _•_ ._- - - - Solar cells Multicrystalline 156•156 mm(6 inches) Fast and simple to install through drop in mounting solution +t Cell orientation 60 cells(6 x 10) •- - ;i Module dimensions 1650 x 992 x 40 mm.(64.95 x 39.05 x 1.57 inches)' 15.91 - t } Q `'t-�' _..1 Weigh} 21.3 kg(47.0 Ibs) � MAXIMUM EFFICIENCY s - ''Glass - 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass - .. - - _ ( A-A Backsheet White 4} Good aesthetics for residential applications. f' j Black Anodized Aluminium Alloy with Trinombunt Groove - .. a• Frame A i I-V CURVES OF PV MODULE(245W) . "IP 65 or IP b7 rated .. J-Box �• ®~+3� - ��. - Photovoltaic Technology cable 4.0 mm2(0.006 inches2), 1 - VVVV j '•Cables -� x to.- - t r '1200 mm(47.2 inches) - POWER OUTPUT GUARANTEE -- - - + Fire Rating Type 2 8.m 800W/m2 /� .. Highly reliable due to stringent quality control • Over 30 in-house tests(UV,TIC,HF,.and many more) 1 6� G bW As a leading global manufacturer f • In-house testing goes well beyond certification requirements # u 4- eeWi TEMPERATURE RATINGS MAXIMUM RATINGS . .. of next generation photovoltaic i '\ - � - am � -- ti .-- -,-,..--•--•-�-_':',- .� ,.,.. �. .� 2DDW/m2 rig Nominal Operating Cell Operational Temperature 40-+g5°C products,we believe close i f'1 2.m j 44°C(±2°q I :_� Temperature(NOCT) I y cooperation with our partners . Maximum System 1000V DC(IECJ 1{ is Critical t0 SUCC@SS. With IOCaI - - - o.m Temperature Coefficient of P- -0.41%/°C Voltage 1000V DC(UL) IY - ( - _ 0.1 IO.a 20*1 30.1 40.m r t. presence around the globe,Trina is - - -' Temperature Coefficient of Voc +-0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service v E r - Y Temperature Coefficient of Isc 0.05%/°C to each customer in each market �-� Certified to withstand challenging'environmental- SI and supplement our innovative, I conditions t j reliable products with the backing I. tr\� • 2400 Pa wind load of Trina as a strong,bankable \' -� + WARRANTY • 5400 Pa snow load F partner. We are committed to building strategic,mutually j 10 year Prod'ucr Workmanship warranty beneficial collaboration with 25 year Linear Power warranty __j installers,developers,distributors (Please refer to product`warranty for details) < and other partners as the o i backbone of our shared success in CERTIFICATION driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY ( `� _ m i PACKAGING CONFIGURATION 10 Year Product Warranty•25 Year Linear Power Warranty , l LIMB °spUB I 1 Modules per box:26 pieces Z' Trina Solar Limited t - - - www.trinasolar.com. � . Iona t - La R�� Modules per 40'conTainer:728 pieces - - 3: Addif t } 6� d 90� 1 Value aue horn Trlga rslinear Oo _ laniY OCAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. oMP4Tl «.r, 7:7- �` - ®2014 T ina Solar Limite .All rights reserved.Specifications included in this datasheet aresubject toI� I�5��u��solar 80R'", +h" 'rY on-asolar _ changer without noticed_ __ - { Smart Energy Together ( R Smart Energy Together ` Years 5 10 IS 20 25' E'-RI- . ❑,Trinastandard .�❑ Inchsrry�rn3daul , ti ` so I a r e 0XoSingle Phase Inverters for North America s o I a r e00 e d µ� SE3000A US/SE3800A US/SE5000A US/SE6000A US/ v ' `° SE7600A US/SE10000A US/SE11400A US k { ,1 ,� �: ,, ? r 4+= - SE3000A-US SE380OA-US SESOOOA-US SE6000A-US SE760OA-US SE10000A-US SE1140OA-US OUTPUT /'�� 9980 @ 208V SolarEdge Single `Phase Inverters i I[7 r Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA ' 1— ..s0000.@zaov,... ................................... F - -• 5400 @ i08V 10800 @ 208V • Max.AC Power Output 3300 4150 6000 8350 12000 VA For North America ....... ...... ...... ......... ... ............ ......... ......... ....................................... ................ ..... ...saso @zaov.... .. io9so @zaov. .. ' ,. � AC Output Voltage Mln:Nom:Max.1t1 183-208-229 Vac - - ✓ ✓ SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ �, ................................. ................ ................................................ .................................. ........................... . AC Output Voltage Min:Nom:Max.l'I ✓ ✓ ✓ ✓ ✓ J J 211 240 264 Vac SE7600A-US/SE10000A-US/SE11400A-US ....- 40.- 64......................... ................ ................................................ ............................... ............................... AC Frequency Min:Nom.Max.1'1 59.3-60-60.5(with HI country setting 57-60-60.5) Hz - 24 @ 208V 48 @ 208V 47.5 .. Max.Continuous Output Current 12.5 16 21 25 32 ... ........................................... ........ -@ 240y................... ..42.@.240V... ............................. GFDIThreshold 1 A . Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes {INPUT f �pverte� t . • - Maximum DC P...... TC) 4050 5100 6750 5300 10250 13500 15350 W ................... ...... ............. ................ ............................ ................. ............. .................................................. a 4 Transformer-less Ungrounded Yes o. g m VeaK {a ., - Max.Input Voltage 500 ...... , # Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc .............. ......... .................. ................ ................ ........................ ..... ............................ ..... .................... ..... .. Max.Input Current(2)................. 9.5 13 L.15.5. .240y..I.......18....I.I......23.......L.305,�p Z240V.. `....34.5 Adc Max Input Short Circuit Current •.. 45 - - ..Adc...- .. ............... ..... ......................... ...........I.... ........... ........ ..............I................. ......... Polarity Protection ............................................... Yes ..... ...................... .................. ......... Ground-Fault Isolation Detection 600ku Sensitivity ._. -...� - ........................................... . ..........:... ............... ............................... ............................. Maximum Inverter Efficiency.....•.... .....97J...... .. ..98.2..... ......983........•..983 98 98 98 % . - .. ......... ......... ............. ................I...............I.998�a1,240V..I........... ....I.................. 97 @ 208V...I............................. CEC Weighted Efficiency 97.5 98 97.5 97.5 97.5 - 97S @.240V.. Nighttime Power Consumption <2.5 <4 W - !ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) _ .......................... .. .. .............�.................................... ............._.... ......... : Revenue Grade Data,ANSI C12.1 O tional ....................................... . ........ ......... .. .. ........ ...... ................. ..................... ..... ................... ......... .. .... + Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed(4) r STANDARD COMPLIANCE .__. . � :X71 >. '. - R Safety ............. ........................................UL1741,UL16999,UL1998,CSA 22.2 • - ............_................. ........................... ....................................... ......... y`. •,y ............................. .......................... ............ CC P rt ................................................ ......... Erid Connection Standards Emissions F 15 class B i INSTALLATION SPECIFICATIONS v AC output conduit size AWG ran e 3 4"minimum 16 6 AWG 3 4"minimum 8 3 AWG �:. - ,«n-:,,...--. q• ! ' `- ................................................................................. ......... • DC input conduit.size/#of strings/ 3/4"minimum/1-2 strings/ . . _. ..' .. " AWG rang?............... 14-6 AWG ,.^' Dimensions with Safety Switch...... ................................................................................ ......30.5 x 12.5 x 10.5./...... ...In%.... f= " 0.5 x112..5 x 7.2/775 Bs 15x184 G 775x315x260 mm 3/4' Weight with Safety Switch .. ........51.2/Z3.2.3...... ................:.54.7/24.7................. ........ 88.4/40.1 ............Ib/kg.. .J • ......................................... ..............................I................................. ................................. ....... „ Natural convection Cooling Natural Convection and internal Fans(user replaceable) - _ - - fan(user The best choice for SolarEdge enabled systems ........................................... ............ ............................... replaaceable)... ............................................. Noise <25 - s 50 dBA ........................................... ................................................................... ................................................................... Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version available(s)) Superior efficiency(98%) gang?................................... ................................ Protection Rating .................................................N EMA 3R Small,lightweight and eas to install on.provided bracket ii•o oh rreg'n regional settings a e' '•• ' """"""'""' """' ""' " ' Y p For Omer current onal settings please contact inverter IA A higher current source may be used;the inverter will limit[s input current to the values stated. .Built-in module-level monitoring ,}' - - pl Revenue grade inverter P/N:SExxxxAUSOOONNR2(for 760OW nvartei:SE7600A-Us002NNR2): 141 Rapid shutdown kit P/N:SE10DO-RSD-Sl. . —'.Internet connection through Ethernet Dr Wireless 1s1-40 version P/N:SExxxx-USOOONNU4(for 760OW inverterSE7600A-US002NNU4). Outdoor and indoor installation .7. Fixed voltage inverter;DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1su�sc>E 0 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us o • • '• • • E