1 r r 1
r TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION
,
Map 2 11 Parcel 425 Application # '
Health Division Date Issued q h1
Conservation Division Application Fee
Planning Dept. Permit FeeSr
Date Definitive Plan Approved by Planning Board
Historic - OKH _ Preservation / Hyannis �� ci 17 LAC-
Project Street Address 10 "YA Ci�i cAxi 3 ZD .
Village aE.-AN 214%LL-
Owner 14V 1-0 A AuGt E 1 1Y 1zir Address sAti
Telephone 4iiftr,- ?? 4- &z 43
Permit Request e-f-t'L.NtZ 1�A� 1 e.7)-46 \A400b 13 IA<.Z '(e-�' So P-7- ffAM
LOLLY cou-wAt�(S a W\m t,4eL W VM$x 4�6
Square feet: 1 st floor: existing proposed 2nd floor: existing proposed Total new
Zoning District - Flood Plain Groundwater Overlay
Project Valuation 3cz�0. Construction Type CA,
Lot Size Grandfathered: ❑Yes ,4 No If yes, attach supporting documentation.
Dwelling Type: Single Family 'A Two Family ❑ Multi-Family(# units)
Age of Existing Structure Historic House: ❑Yes ANo On Old King's Highway: ❑Yes ANo
Basement Type: A Full ❑ Crawl ❑Walkout ❑ Other
Basement Finished Area (sq.ft.) Basement Unfinished Area (sq.ft)
Number of Baths: Full: existing Z/ new Half: existing new
Number of Bedrooms: existing _new
Total Room Count (not including baths): existing new First Floor Room Count
Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑ Other
Central Air: ❑Yes ❑ No Fireplaces: Existing New Existing wood/coal stove: ❑Yes ❑ No
Detached garage: ❑ existing ❑ new size_Pool: ❑ existing ❑ new size _ Barn: ❑ existing ❑ new size_
Attached garage: ❑ existing ❑ new size _Shed: ❑ existing ❑ new size _ Other:;�0
Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ cm
Commercial ❑Yes No If yes, site plan review # IMU
Current Use .f,- Proposed Use
APPLICANT INFORMATION
(BUILDER OR HOMEOWNER)
Name c5 Axi i b cF,M Telephone Number sbcq
Address : A OLD orS-tTL M License # C'S - C*S`3`�S
C'(9Ti'L� °lam , 1 Q GzO / Home Improvement Contractor# 13 1 ss�)
Email 6 GoM00 St .i?e�_ Worker's Compensation #
ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO
SIGNATURE DATE ° b
FOR OFFICIAL USE ONLY
APPLICATION #
DATE ISSUED
MAP/ PARCEL NO.
ADDRESS VILLAGE
OWNER
r
I
DATE OF INSPECTION:
FOUNDATION
F
FRAME
INSULATION
FIREPLACE
ELECTRICAL: ROUGH FINAL
4
PLUMBING: ROUGH FINAL
`GAS: ROUGH FINAL
FINAL BUILDING
DATE CLOSED OUT
ASSOCIATION PLAN NO.
" . 1 • - 1. - .
of rO y Town of Barnstable _
Regulatory Service
MA�CM_ �. Richard P.Sc2A Iirecbor
m
k1 Building Division'
Tom rerry,Bmffidmg Cammssioner
200 Main Sfreet Hy=±%MA 02601
www.townbarnsfable mans
Office: 50 8-862-4 03 8 F= 50 8-790�23 0
•Prope4 Owner Must '
Complete aud.Sign•This Section
` If Us ing A Builder
i-L-,.,. :[IY L?T- ,as OWMr of the subject property
herebyautbL0ZMZ > to act on mybahA
in all matters MI iVU to wark authoazed bythis bmmIding permit application far.
1dr?. n�
a PI�, C. � Q-
(Alfmss of job)
"Pool fences and alaxms are tb-e responsilBh7of the applicant Pools
are not to be filled or ill&d before fence is installed and all final
inspections•are pedo=d•and accepted.
(34� of Owner Signature of AppEcant
bAg v%> my t�,TT—
PrintName Pri T Name
Date
�FoxMs:awr��smi�oors •
Town of Barnstable
Regalatorp Services '
ova r � Richard V.ScT;Dir r
BidIding Division
F r
ABS. r : Tom Perry,Building 03mmkdoner
p4a z63g- .ate 200 Main HY=3is,MA 02601
vrww tombarnsfable-ma-irs
Office: 508-862-4038 - Fay 508-790-6230
' - HOMEOWKE.g LIf�R.�'IION
• �PIexse Pcint
MIS-
7oB LOCATIOK- s[xect
ri CE'
'80I�lEO�T2�
h®cphoac# woz3cplianc
cURRENT MAILIDIGADDRFSS: _
ctfy/fin s� up CO&
The current exemption for`h omeowne&'was extended fn mclIIde owner-occMied dweIIin�s of s�units or less and fo allow
homeovmr,rs to engage an individual for hire who does notpossess a license,provided that the owner acts as Lmr_
DEFIIZrrLON OF HOMEOWNER
p mon(s)who omens a parcel of land on which he/she resides or hitrnds to reside,on which-there is,or is intended to be,a one or tvvo-
family dwelling, attached or detad3ied stractores accessory to Inch use and/or fZ=sfriicha es. A person who contracts mare than one
home in a two-year period shaI1 not be couddcred.a homeowner Such`°homeownee'.shall sobmitto the B-TrUn Official on a form
acceptable to the BmZdmg Officia],that hr/sha shall be res�ansinIe far aIl sash work perfoffied�dertha bm7dina permit (Sediaa
109.L 1)
Tho rmdersigned`,`homeownrx'a samcs respons1191 y for compliance withthe Siafe Bm7dmg Coda and ofhei applicablo codes,
bylaws,rules and regalrations-
r
'Ihc�gned`•hnmeo�vnez"cedifies fhathelshe��*+ nay the Toed ofB�siable$w1dmg Depaaz�t�mspectinn
pm=dnres and requirements and that hclshe wM comply with said procedmca and regoeme ts-
' Sip�aeacofHnmca�aa - ,
App=Y-I ofBm7cmgOfficial
. Note. Three family dweIlmp containing 35,000 cubic fief or larger wffibe rmpis d to comply wi&the gtate Building Code
Seddon 1'27.0 Consft�n ContML
HOMED Wi�B'S EI�ff2IO1I
The Code states that: "Any homeowner performing workfAr which a building permit is reqrdred shall be exempt
from the provisions of this section(Section 109-LI-Licensing of construction Sapervisors);provided that if the homeowner
engages a person(;)for bite to do such work,that such Homeowner shah act as supervisor."
'
Macy homeowners who use this ezempfron are naaware•that they are assv�n+�,the rm?ousibiliities of a sapervisor
(see Appendix Q,Rnies Bc Regulations for 1Acevskg.Const mc&n Supervisors;Section ZIS) Ibis Lark of awareness oftea
results ui serious problems,pasfiedlarly when the homeowner hires=Tceased persons- In this case,our Board cannot
proce6d against the=Hcaosed pmsoa as it would with a Ii—red Supervisor_ The homeowner acing as Superrimr is
ultimately responsible.
To ensure'tkat the homeowner is fnIIy aware of his/her respons Mes,many eommmAffes regnnre,as part of fhe
permit application, that the homeowner certify that he/she understands the responsibiTties of a Supervisor. On the List page
of this issue is a form currently used by,several towns. Yon may caret amend and adopt sacli a fo rmictrfifL�nn.for use in
your cammu:dfp
Ql�7PFII�S�f'bB�d�lf"•�—;*^a Pemzitf�sl�FBFSS.doc
Revised 0613 13
:a
EN INEERING, LC
STRUCTURAL:AND CIVIL ENGINEERING
Page 1 of 1
Myett Lt. 15204.01
October 22, 2015
Dave Myett
147 Yacht Club Road
Centerville, MA 02632
Job No. 15204
Re: Structural Evaluation and design of the Specific Components in the Residence
Known as 147 Yacht Club Road, Centerville,MA
Mr.Myett,
As requested, I met with you at 147 Yacht Club Road to observe the proposed tally column
removal scheme. I evaluated the structure and offer the proposed changes shown in the attached
Sheets SK-1 and SK-2.
The columns and existing girder can be.removed after the temporary walls are erected on each
side of the girder up to the underside of the existing first floor joists. The new beam may be sized
to fit in beam pockets in the foundation or sized to fit within the wall to wall dimensions(22'-2")
and bear on columns at each end. The columns Will bear directly on the slab which is assumed to
bear on the foundation wall footing extension: The recommended girder replacement choices are
as follows.
1. An ASTM A-36 or better WIOx26. This beam is 10-3/8" deep and 5-3/4" wide and
weighs 572#. Add a 3/4"plywood nailer on top and the overall girder is 11-1/8" deep.
With joists at 881/2"off the slab,the headroom under the unfinished girder is 6'-5"
2. An ASTM A-36 or better W8x40. This beam is 81/4"deep and 8"wide and weighs 880#.
Add a 3/4"plywood nailer on top and the overall girder is 9"deep. With joists at 881/2"off
the slab,the head room under the unfinished girder is 6'-71h".
3. An ASTM A-36 or better W10x33. This beam is 91/4" deep and 8" wide and weighs
726#. Add a V plywood nailer on top and the overall girder is 10%2" deep. With joists
at 881/2"off the slab,the head room under the unfinished girder is 6%6".
1
This evaluation was performed assuming the subject single family dwelling was erected in
accordance with the Massachusetts Building Code in effect at the time of construction. It is
recommended that Phelan Engineering or suitable agent be employed to verify proper
construction. Please feel free to copy this letter to others as desired and call if you have any
questions or comments. ,. 4.
-\\A OF MqSJ9cti
Regards, PAUL A. G
`�'�
PHELAN JR.
,L'�'1 STRUCTURAL
'b No.42538
o GIs Q
Paul A. Phelan,Jr.,P.E. 5) G�A01
S�IONAL�
12 SLEIGH ROAD A CHELMSFORD, MA 01824
(978) 256-4014 . FAX`(978) 250:73764 . www.PhelanEngineering.com
• pJ0e - i1�it'�
1 H N SHEET NO. • OF S -L
EN NEE I NG CALCULATED BY _Pi4 DATE
12 SLEIGH ROAD CHELMSFORD,MA 01824 -
(978j256.4014 CHECKED BY DATE
SCALE
............_€..............
...............................'_.. ..... ....
....i.... ._.......
T
� 7 `I t�41N` G�J
.....;....
--- .....
...r..........................:....._...._............:....._..:.........._.. .....
... ..._ .....
x�sr N t- wv ... 3 A SIM ¢.......J do .. ....TO. ....
..........:.......................... ........... ._._........ ...,......._,,_............ c� t ti
�20M.
:.......T.a.................... .N r�.v.........t,J /a x rd
........... . -..... ..... ......
_.
uj 4-
.,
............_.............i................................... ..... ..... ...... ...... ..... ...... ......
��. n
.....:........._.. i.......-r. ............_......_...........:_.
. !
........................ ..........._........._._i_........... .....
...A`i�.�l : �O�u Mkt ...
:. ..;.� 1 ....`_
.:... ..:;...
_
::.
- .....
s............
:
.............`...........__................_...._..........
.................. .
l" .... ..... .._. ...
............i.............. ......................€.............':.......................:. D
......................... ..................._ST.... ................. .....
..... .....
..... ............ ...... ....o......
3�
o0
p.il ..:..... ...... -=-�-�... _. . .... _..:..... _..:....
....._ ..-... ...... _ ....
.
............._.........._:............,._.........;..........._:........:.....: X�
......................_ ......... ............._.. ........... - ..........-
.._
;
r
_ Co Xu
.......................
.. z � ,
......
OL
...._�..:..........._e ....)..: ........ .._x.
SS
5
�>.
I Pt A,r
v._... ..........t .c. �s....... ..............................
........._.............._......._......: ...3........_r.,..... i..... ...-.
11. ..... ......
............_............_....... ...s........ i
G i.;........... ............... . '...:.... ....:.._. ......... ....... _.... ..
...... ..... _........... _._ ...... ....
i
......:....
............a.............:....... .................:..........._...... ......
..... ......
:....... :..........
1
..................................................... ...........
..!...__...._'._...... _....
4
...... ..._.:...........<......:.:... 14*
......:.:.:..,:............: ...... .... .....
i%A
...........
............ ......__....__ ... ...b.... .... ........:................... w.- .......:..........._._..
onrvua�r nn..�icrr.ew.:m.rer•.n - �
EN vINEERING, LC
STRUCTURAL AND CIVIL ENGINEERING
Page 1 of 1
Myett Lt..15204.01
- October 22, 2015
Dave Myett-
147 Yacht Club Road
Centerville, MA 02632
Job No. 15204
Re: Structural Evaluation and design of the Specific Components in the Residence
Known as 147 Yacht Club Road, Centerville,MA
Mr.Myett,
As requested, I met with you at 147 Yacht Club Road to observe the proposed lall column
q � y - P P y
removal scheme. I evaluated the structure and offer the proposed changes shown in the attached.
Sheets SK-I and SK-2.-
The columns and. existing girder can be removed after the temporary walls are erected on each
P �'Y
i the girder
se f.d o e g de up to the underside of the existing first floor.joists. The new beam may be sized
to fit in beam pockets in the foundation or sized to fit within the wall to wall dimensions(22'-2")
and bear on columns at each end. The columns will bear directly on the slab which is assumed to
bear on the foundation wall footing extension. The recommended girder replacement choices are
as follows. ,
1. An ASTM A-36 or better W10x26. This beam is 1.0-3/8' deep and,5-3/4" wide and
weighs 572#. Add a 3/4" plywood nailer on top and the overall girder is 1.1-1/8" deep.
With joists at 881/2"off the slab,the head room under the unfinished girder is 6'-5"'
2. An ASTM A-36 or better W8x40. This beam is 81/4"deep and 8"wide and weighs 880#.
Add a 3/4"plywood nailer on top and the overall girder is 9"deep. With joists at 881/2"off
the slab,the head room under the unfinished girder is 6'-71/z".
3. An'ASTM A-36 or better WlOx33. This beam is 9'/4" deep and 8" wide and weighs
726#. Add a%" plywood nailer on top and the overall girder is 10'/2" deep. With joists
at 881/2"off the slab,the head room under the unfinished girder is 6'-6".
This evaluation was performed assuming the subject single family dwelling was erected in
accordance with the Massachusetts Building Code in effect at the time of construction. It is
recommended that Phelan Engineering or suitable agent be employed to verify proper 1
construction. Please feel free to copy this letter to others as desired and call if you have any
questions or comments.
��NbFM,
`J` PAUL
Regard, � � ,
PNELAN JR. = i
t STRUCTURAL cn
8' Ni.42533
Paul A.Phelan,Jr.,P.E. s. e�FssrtrvM- G,`��ti
1.2 SLEIGH ROAD • CHELMSFORD, MA 01824 - -
(978) 256-4014 e FAX (978) 250-:3764 a www.PhelanEngineering.com
'~ r` TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION
Map 1/ Parcel O25 „Application #cOl 5A 13
Health Division Date Issued 215'
Is-AIL
Conservation Division Application Fee
Planning Dept. Permit Fee i
Date Definitive Plan Approved by Planning Board
Historic - OKH _ Preservation / Hyannis
Project Street Address )9 7 c l.,6
Village CE+-.4Kr,J,l�l
Owner rv, L ���� ��- Address A -
Telephone
Permit Request cc10-)I
Square feet: 1 st floor: existing proposed 2nd floor: existing proposed Total new
Zoning District Flood Plain Groundwater Overlay
Project Valuation Construction Type
Lot Size Grandfathered: ❑Yes ❑ No If yes, attach supporting documentation.
Dwelling Type: Single Family La/ Two Family ❑ Multi-Family (# units)
Age of Existing Structure Historic House: ❑Yes ❑ No On Old King's Highway: ❑Yes ❑ No
Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑Other Y
y
Basement Finished Area (sq.ft.) Basement Unfinished Area (sq.ftp
Number of Baths: Full: existing new Half: existing new-,-
Number of Bedrooms: existing _new
--a
Total Room Count (not including baths):-existing new First Floor Roo Count 1
'3 Ica
Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑Other
Central Air: ❑Yes ❑ No Fireplaces: Existing New Existing wood/coal stove: ❑Yes ❑ No
Detached garage: ❑ existing ❑ new size_Pool: ❑ existing ❑ new size _ Barn: ❑ existing ❑ new size_
Attached garage: ❑ existing ❑ new size _Shed: ❑ existing ❑ new size _ Other:
Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑
Commercial ❑Yes ❑ No If yes, site plan review#
Current Use Proposed Use
APPLICANT INFORMATION
- (BUILDER OR HOMEOWNER)
Name Mike McCarthy Construction Telephone Number
PO Box 52
Address West Dennis, MA 02670 License#
Cell (508) 280-6964
CSL-58633 HIC-169393 Home Improvement Contractor#
Email Worker's Compensation #
ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO
SIGNATURE DATE 31�7 ll
FOR OFFICIAL USE ONLY
APPLICATION#
rT. ,
DATE ISSUED
v MAP/PARCEL NO.
ADDRESS VILLAGE
OWNER
DATE OF INSPECTION:
FOUNDATION
FRAME
INSULATION
FIREPLACE
ELECTRICAL: ROUGH FINAL
PLUMBING: ROUGH FINAL
GAS: ROUGH FINAL
FINAL BUILDING
� f
DATE CLOSED OUT
f ,
r ,
ASSOCIATION PLAN NO.
f
Town of Barnstable
°4 Regulatory Services
S Richard V.Scali,DIrector
16}9 10�
Building Division
'Pom Perry,Building Commissioner
200 Main Street,Hyannis,IMA 02601
vv w w.town.barnstable.ma.us
Office: 508-8624038 Fax: 508-790-6230
Property Owner Must
Complete and Sign This Section
If Usin,A Builder
V I d � ,as 0wrier of the subject pro�lerty
hereby authorise. S o act on my behalf,
in all matters relative to work authorized -this building pernvt application for:
l ?_ �a.G r1.T— t;u,tb K it _ C e 0�rV( L-�
(Address of fob)
Pool fence's and alarms are the responsibility of the applicant. Pools .
are not to be filled or utilized before fence is installed and all finJ—
inspections performed and accepted.
- - � '
S nature of Owner Signature of.Applicant
Print Name Print Narric:
Date
Q:FORMS-OW'\T.RP'r.R1dISS10NPOOLS
i
Assessor's office(1st,Floor):
Assessor's map and lot number �( rj�(p SEPTIC SYSTEM MID ME ro`
Board of Health(3rd floor): /�/ t3 t `NT• rf i INSTALLED IN COMP
Sewage Permit number �� 2"
WITH TITLE 5 t 3AassTADLE
Engineering Department(3rd floor)':
House number
Definitive PlamApproved by Planning Board t 19 i :�,; p y�Y b•
APPLICATIONS PROCESSED 8:30-9:30 A.M.:and 1:00-2:00 P.M.only
TOWN ., OF BXANSTABLE
' BUILDING `-INSPECTOR
APPLICATION FOR PERMIT TO
TYPE OF CONSTRUCTION
19
s
TO THE INSPECTOR OF BUILDINGS:
The undersigned hereby applies for a permit according to the following information:
Location
� 1
Proposed Use ��i,
Zoning District Fire District
Name of Owner �� S� Qo�g� t nN Address (eAn j-f a W ,_RDXD U.
Name of Builder C'1 P -,1N Q, j 61- Address__ d e, Ad4 r
Name of Architect Address
/' 11
Number of Rooms Foundation -
Exterior j Roofings
1 Floors 0;. Interior
is c�-�� �,.s PVumbin 9 ' 3 Heating (9-1
Fireplace 1\/ [ -9— Approximate Cost
Area
Diagram of Lot and Building with Dimensions Fee
Ito°
I 3c7`
I
- I
r
0
C*JU6wH
V
I �
� tof
ANNA
OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS
I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction.
Name ow Pn
Construction Supervisor's License 7
SALADINO, ROBERT �
-s No 34061 Permit For Remodel & Addition
'y Single Family Dwelling �> -
Location 147 Yacht Club Road
Centerville
Owner. Robert Saladino
y
Type of Construction Frame
Plot Lot
Permit Granted November 1.4; `719 90
Date of Inspection ` �J 19
Date Completed l�s�7 Z-- 19
�p �;," �,.. _ • � ,.� i '' ems'' � � .'
t
,t. s
i 6
i
_
— — --- --- ----� — — r---- j - __ - w/ I� F R;EcDE
0 Q ' AND O �`
x "' STEM
O O
_ I RAT
¢ x � m
RFC
.4 a _;#
1 2-
'low
Cl
Cl
�
+ X "N Irl
7 6 �3
St
A
52—
,�° 6 41
IL
Air � i V
O NOTE C
i I SCALE: "c iJ APPROVED BY. A, DRAWN BY.
-;
011 le
DATE REVISED
DRAWING NUMBER
u � y
-
.. ..- - ..... ... .....
a,
yx
It" 4
t
t
r
,r
1 }}}
i
r '
r'...a "�a„" _.•,� N��.�`.T�mµ " s �'11'4 t .',X' rib ,. . `�Y" -r.'�.`� w 'xi <
f s"x
'fir i �,.' (� �' � �'�� t '° * I �t � �� air ��'T"�,:� �<�7�' �i r Ssn'd'•yam f �-� -
�t W
t ,
s
c
fi
•
I
! ! Pt_y w _s e/4-r fl'/6-" --
I
XX VVAU,5
C
fur-
I�
E
J�
1
f
f
1
AJ
y
l x, B Get C Ll
/ A
At
4
'A ll
f
SCALE: APPROVED BY: DRAWN BY:
DATE: REVISED
lf` r � n
DRAWING NUMBER