SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION
Property Address: 54 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Address of Owner: 9 SARGENT LANE CRAIGVILLE MA.02636
Date of Inspection: 6/9/00
Name of Inspector: JOHN GRACI
I am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000)
Company Name: SEPTIC INSPECTIONS
Mailing Address: P.O.BOX 2119 TEATICKET,MA.02636
Telephone Number: 608-664-6813 FAX 508-664-7270
CERTIFICATION STATEMENT t x
I certify that I have personally inspected the sewage.disposal system at this address and that the information reported below�s I e,accurate
and complete as of the time of inspection-The inspection was performed based on my training and experience in the proper function and
maintenance of on-site sewage disposal systems.The system:
X Passes
_ Conditionally Passes
_ Needs Further Evaluation By the Local Approving Authority 4 0
_ Fails
o 2s� 02
Inspector's Signature: Date:6 11/0016®:e�
4 '
The System Inspector shall submit ailopy of this inspection report to the Approving Authority(Board of Health or DEP)within thirty(30)days of
completing this inspection.If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner
shall submit the report to the appropriate regional office of the Department of Environmental Protection.The original should be sent to the
system owner and copies sent to the buyer,if applicable,and the approving authority.
NOTES AND COMMENTS
"The inspection is based on criteria defined in Title V code 310 CMR 15.303.My findings are of how the system is performing at the time of inspection.My
inspection does not imply any warranty or guarantee of the longevity of the septic system and any of its component's useful life:"
THE SYSTEM PASSES TITLE V INPECTION.THE SYSTEM CONSISTS OF A CESSPOOL WITH ALECH TRENCH,THE SYSTEM IS NOT TITLE,
HOWEVER MEETS PASSING STANDARDS AT TIME OF INSPECTION.THE SYSTEM WAS NOT INSPECT UNDER NORMAL USE.RECOMMEND
PUMPING THE EVERY YEAR TO V RDRD Oc)S � J�S�(.t�`� v�2 �j L\ � e✓
t s=
r
;P
revised 9/2/98 Page 1 of 11
TO``W����N�3ARNSTABLE
LOCATION �f VU SEWAGE #
VILLAGE ASSESSOR'S MAP & LOT
INSTALLER'S NAME&PHONE NO.
SEPTIC TANK CAPACITY
LEACHING FACIL=: (type) (size)
NO. OF BEDROOMS
BUILDER OR OWNER
PERMITDATE: COMPLIANCE DATE:
Separation Distance Between the:
Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet
Private Water Supply Well and Leaching Facility (If any wells exist
on site or within 200 feet of leaching facility) Feet
Edge of Wetland and Leaching Facility(If any wetlands exist
within 300 feet of leaching facility) Feet
Furnished by
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 64 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 6/9/00
INSPECTION SUMMARY: Check A, B, C, or D:
A. SYSTEM PASSES:
X I have not found any information which indicates that any of the failure conditions described in 310 CMR 15.303 exist.Any failure criteria not evaluated
are indicated below.
B. SYSTEM CONDITIONALLY PASSES:
One or more system components as described in the"Conditional Pass"section need to be replaced or repaired.The system,upon completion of the
replacement or repair,as approved by the Board of Health,will pass.
Indicate yes,no,or not determined(Y,N,or ND).Describe basis of determination in all instances.If"not determined",explain why not.
Wa The septic tank is metal,unless the owner or operator has provided the system inspector with a copy of a Certificate of Compliance
attached)indicating that the tank was installed within twenty(20)years prior to the date of the inspection;or the septic tank,
whether or not metal,is cracked,structurally unsound,shows substantial infiltration or exfiltration,or tank failure is imminent.The
system will pass inspection if the existing septic tank is replaced with a complying septic tank as approved by the Board of Health.
n1a Sewage backup or breakout or high static water level observed in the distribution box is due to broken or obstructed pipe(s)or due
to a broken,settled or uneven distribution box.The system will pass inspection if(with approval of the Board of Health).
_broken pipe(s)are replaced
_obstruction is removed
_distribution box is levelled or replaced
n& The system required pumping more than four times a year due to broken or obstructed pipe(s).The system will pass inspection if
(with approval of the Board of Health):
_broken pipe(s)are replaced
_obstruction is removed
era
revised 9/2198 Page 2 of 11
a
f
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 54 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 6/9/00
C. FURTHER EVALUATION IS REQUIRED BY THE BOARD OF HEALTH:
Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect the public health,safety
and the environment.
1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES IN ACCORDANCE WITH 310 CMR 16.303(1)(b)THAT THE SYSTEM IS
NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT ThE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT:
Cesspool or privy is within 50 feet of surface water
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh.
2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH(AND PUBLIC WATER SUPPLIER.IF ANY)DETERMINES THAT THE SYSTEM IS
FUNCTIONING IN A MANNER THAT PROTECTS THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT:
The system has.a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a
surface water supply.
The system has a septic tank and soil absorption system and the SAS is within a Zone I of a public water supply well.
The system has a septic tank and soil absorption system and the SAS is within 50 feet of a private water supply well,
_ The system has a septic tank and soil absorption system and the SAS is less than 100 feet but 50 feet or more from a
private water supply well,unless a well water analysis for coliform bacteria and volatile organic compounds indicates that the
well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less
than 5 ppm,Method used to determine distance Wit(approximation not valid).
3) OTHER
n/a
revised 9/2/98 Page 3 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECKLIST
Property Address: 54 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner: CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 619/00
Check if the following have been done:You must indicate either"Yes"or"No"as to each of the following:
Yes No
X _ Pumping information was provided by the owner,occupant,or Board of Health.
X _ None of the system components have been pumped for at least two weeks and-the system has been receiving normal flow rates during that period.
Large volumes of water have not been introduced into the system recently or as part of this inspection.
_ X As built plans have been obtained and examined.Note if they are not available with N/A.
X - The facility or dwelling was inspected for signs of sewage back-up.
X - The system does not receive non-sanitary or industrial waste flow.
X _ The site was inspected for signs of breakout.
X _ All system components,excluding the Soil Absorption System,have been located on the site.
X _ The septic tank manholes were uncovered,opened,and the Interior of the septic tank was inspected for condition of baffles or tees,material of
construction,dimensions,depth of liquid,depth of sludge,depth of scum.The size and location of the Soil Absorption System on the site has been
determined based on:
X _ Existing information,For example,Plan at B4O,H,
X - Determined in the field(if any of the failure criteria related to Part C is at issue,approximation of distance is unacceptable)1 5.302(3)(b))
X _ The facility owner(and occupants,if different from owner)were provided with information on the proper maintenance of SubSurface Disposal
Systems.
revised 9098 Page 5 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 54 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 6/9/00
D. SYSTEM FAILS:
You must indicate either"Yes"or"No"to each of the following:
I have determined that one or more of the following failure conditions exist as described in 310 CMR 15.303.The basis for this determination is
identified below.The Board of Health should be contacted to determine what will be necessary to correct the failure.
Yes No
- X Backup of sewage into facility or system component due to an overloaded or clogged SAS or cesspool.
X Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool.
_ X Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool.
X Liquid depth in cesspool is less than 6"below invert or available volume is less than 1/2 day flow,
- X Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).Number of times pumped 0.
- X Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater elevation.
- X Any portion of a cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply.
X Any portion of a cesspool or privy is within a Zone I of a public well.
X Any portion of a cesspool or privy is within 50 feet of a private water supply well,
_ X Any portion of a cesspool or privy is less-than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality
analysis.If the well has been analyzed to be acceptable,attach copy of well water analysis for coliform bacteria,volatile organic compounds,
ammonia nitrogen and nitrate nitrogen.
E. LARGE SYSTEM FAILS:
You must indicate either"Yes"or"No"to each of the following:
The following criteria apply to large systems in addition to the criteria above:
The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a significant threat to public health and
safety and the environment because one or more of the following conditions exist:
Yes No
X the system is within 400 feet of a surface drinking water supply
X the system is within 200 feet of a tributary to a surface drinking water supply
- X the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or a mapped Zone II of a public water supply well)
The owner or operator of any such system shall upgrade the system in accordance with 310 CMR 15.30412).Please consult the local regional office of the
Department for further information.
a.
revised 9/2/98 Page 4 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION
Property Address: 54 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 6/9/00
FLOW CONDITIONS
RESIDENTIAL:
Design flow: 110 g.p.d./bedroom
Number of bedrooms(design): 3 Number of bedrooms(actual):
Total DESIGN flow: 330 gpd
Number of current residents:n/a
Garbage grinder(yes or no):NO
Laundry(separate system)(yes or no): NO If yes,separate inspection required
Laundry system inspected(yes or no): NO
Seasonal use(yes or no): NO
Water meter readings,if available(last two year's usage): n/a gpd
Sump Pump(yes or no): NO
Last date of occupancy: n/a
COM M ERCIAL/INDUSTRIAL
Type of establishment: n/a
Design flow: n/a gpd(Based on 15.203)
Basis of design flow:n/a
Grease trap present:(yes or no): NO
Industrial Waste Holding Tank present:(yes or no): NO
Non-sanitary waste discharged to the Title 5 system:(yes or no):NO
Water meter readings.if available: n/a
Last date of occupancy:n/a `
OTHER: (Describe)
n/a
GENERAL INFORMATION
PUMPING RECORDS and source of information:
n/a
System pumped as part of inspection:(yes or no):NO
If yes,volume pumped n/a gallons
Reason for pumping:n/a
TYPE OF SYSTEM
X Septic tank/distribution box/soil absorption system
_ Single cesspool
_ Overflow cesspool
_ Privy
_ Shared system(yes or no)(if yes.attach previous inspection records,if any)
_ I/A Technology etc.Attach copy of up to date operation and maintenance contract
_ Tight Tank Copy of DEP Approval
Other:n/a
APPROXIMATE AGE of all components,date installed(if known)and source of information:
30+YEARS OLD.
Sewage odors detected when arriving at the site:(yes or no) NO
revised 9/2/98 Page 6 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 54 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 6/9/00
BUILDING SEWER:X
(Locate on site plan)
Depth below grade: 6"
Material of construction: _ cast iron _ 40 Pvc X other(explain)
Distance from private water supply well or suction line: n/a
Diameter: n/a
Comments: (condition of joints,venting,evidence of leakage,etc.)
THERE IS TOWN WATER
SEPTIC TANK: X
(locate on site plan)
Depth below grade: 1"
Material of construction: X concrete_ metal_ Fiberglass_ Polyethylene_ other
explain: n/a
If tank is metal,list age Is age confirmed by Certificate of Compliance(Yes/No): NO
Age: n/a
Dimensions: 6'X6'BLOCK CESSPOOL"
Sludge depth: n/a
Distance from top of sludge to bottom of outlet tee or baffle: n/a
Scum thickness: n/a
Distance from top of scum to top of outlet tee or baffle: n/a
Distance from bottom of scum to bottom of outlet tee or baffle: n/a
How dimensions were determined: MEASURED
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,
etc.)
MAIN CESSPOOL AND ALL COMPONENTS ARE STRUCTURALLY SOUND.THE CESSPOOL WAS EMPTY.RECOMMEND PUMPING EVERY ONE
YEAR TO PROLONG THE SYSTEM'S USEFULL LIFE
GREASE TRAP: _
(locate on site plan)
Depth below grade: n/a
Material of construction: _concrete_ metal_ Fiberglass _ Polyethylene_other
Explain: n/a
Dimensions:n/a
Scum thickness: n/a
Distance from top of scum to top of outlet tee or baffle: n/a
Distance from bottom of scum to bottom of outlet tee or baffle n/a
Date of last pumping: n/a
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,
-etc.)
n/a
revised 9/2/98 c Page 7 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 54 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 619100
TIGHT OR HOLDING TANK: _ (Tank must be pumped prior to,or at time of,inspection)
(locate on site plan)
Depth below grade: n/a
Material of construction: _concrete_ metal_Fiberglass _Polyethylene _other
Explain: n/a
Dimensions: n/a
Capacity: n/a gallons
Design flow: n/a gallons/day
Alarm present: NO
Alarm level:N/A Alarm in working order:NO
Date of previous pumping: n/a
Comments:
(condition of inlet tee,condition of alarm and float switches,etc.)
n/a
DISTRIBUTION BOX:_
(locate on site plan)
Depth of liquid level above outlet invert: n/a
Comments:
(note if level and distribution is equal,evidence of solids carryover,evidence of leakage into or out of box,etc.)
n/a
PUMP CHAMBER: _
(locate on site plan)
Pumps in working order:(Yes or No): NO
Alarms in working order(Yes or No): NO
Comments:
(note condition of pump chamber,condition of pumps and appurtenances.etc.)
n/a
Fr•
revised 9/2198 Page 8 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 54 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 6/9/00
SOIL ABSORPTION SYSTEM(SAS): X
(locate on site plan,if possible;excavation not required,location may be approximated by non-intrusive methods).
If not located,explain:
n/a
Type:
leaching pits,number:(n/a)n/a
leaching chambers,number: (n/a)n/a
leaching galleries,number: (n/a)n/a
leaching trenches,number,length: (1)20
leaching fields,number,dimensions: (n/a)n/a
overflow cesspool,number: (n/a)n/a
Alternative system: n/a
Name of Technology: n/a
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.)
THE LEACH TRENCH APPEARS TO BE FUNCTIONING PROPERLY.IT IS 2'X 4'X 20'.THE SYSTEM WAS INSPECTED WHEN THE HOUSE WAS
UNOCCUPIED.
CESSPOOLS: _
(locate on site plan)
Number and configuration: n/a
Depth-top of liquid to inlet invert: n/a
Depth of solids layer: n/a
Depth of scum layer. n/a
Dimensions of cesspool: n/a
Materials of construction: n/a
Indication of groundwater: n/a inflow(cesspool must be pumped as part of inspection)NO
Comments:
(note condition of soil,signs of hydraulic.;failure,level of ponding,condition of vegetation,etc.)
n/a E,
PRIVY:
(locate on site plan)
Materials of construction: n/a Dimensions: n/a
Depth of solids: n/a
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.)
n/a
revised 9/2/98 Page 9 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 64 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 6/9/00
SKETCH OF SEWAGE DISPOSAL SYSTEM:
include ties to at least two permanent reference landmarks or benchmarks
locate all wells within 100'(Locate where public water supply comes into house)
O ,
revised 9/2/98 Page 10 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 54 SOUNDVIEW AV CENTERVILLE, MA 02636
Name of Owner CARROLL WHITTEMORE C/O GEORGE AND MARY BORTON
Date of Inspection: 6/9/00
NRCS Report name: n/a
Soil Type: n/a
Typical depth to groundwater: n/a
USGS Date website visited: n/a
Observation Wells checked: NO
Groundwater depth: Shallow_ Moderate_ Deep_
SITE EXAM _ Slope
_ Surface water
_ Check Cellar
_ Shallow wells
Estimated Depth to Groundwater 10 Feet n/a
Please indicate all the methods used to determine High Groundwater Elevation:
Obtained from Design Plans on record
Observed Site(Abutting property,observation hole,basement sump etc.)
Determined from local conditions
Checked with local Board of health
_ Checked FEMA Maps
_ Checked pumping records
_ Checked local excavators,installers
X Used USGS Data
Describe how you established the High Groundwater Elevation.(Must be completed)
USGS MAPS AND CHARTS-10 FEET
revised 9/2/98 Page 11 of 11
f Town o I��s • ablea
_ —
Department of Health,Safety,and Environmental Services
aFWE Public Health Division Date
367 Main Street,Hyannis MA 02601
l
1639 , Date Scheduled / L/ J000 Time Fee Pd. 1(20
AjEO MAt
Soil Suitability Assessment for Sewage disposal
Performed By: V A Ifs 101 y/. Ku[.•Cl t . Ce. Witnessed By: I t
,:. .
I�� ATON& GENRA I1�IFORMAT�(�N
Location Address 5�- �o�✓'t:�V I<?.t.� Nue Owner's Name
t: vr"t-i V t ilp- Address
Assessor's Map/Parcel: 17Z.7 s-p 4 q-7 Engineer's Name
NEW CONSTRUCTION REPAIR V" Telephone#
Land Use 5,1(n,.- Slopes N 3 - U'1c Surface Stones P✓a
Distances from: Open Water Body ft Possible Wet Area 00 ft Drinking Water Well ft
Drainage Way ft Property Line ft Other ft
SKETCH:(Street name,dimensions of lot,exact locations of test holes&perc tests,locate wetlands in proximity to holes)
S��•��° � raj,t�
W.Z77- P. q7 Ate,Z,7 P,
S OvIVDVick/
)FOAL
Parent material(geologic) d()4-l.✓<-S Depth to Bedrock
Depth to Groundwater: Standing Water in Hole: p IAA' Weeping from Pit Face
Estimated Seasonal High Groundwater
DE`t'Et I ATtOX DR SI✓t O AID G-1l::: ~-P, "T� LE
Method Used:
Depth Observed standing in obs.hole: in. Depth to soil mottles: in.
Depth to weeping from side of obs.hole: in. Groundwater Adjustment ft.
Index Well#_._..._.,.,_ .Reading Date:,_ Index Well level ___ Adj.factor Adj.Groundwater Level_._._
.
PERCOLAT (�►N TEST Dtt :T�mc
... .... .........::.::.
Observation
Hole# ` Time at 9"
Depth of Pere
- P � Time at 6"
Start Pre-soak Time @ 16110 d Time(9"-V)
End Pre-soak (c l�AY0--m,-,en,
Rate Min./Inch
Site Suitability Assessment: Site Passed Site Failed: Additional Testing Needed(Y/N)
Original: Public Health Division Observation Hole Data To Be Completed on Back j
Copy: Applicant
DEEP 0BER' ATYQlr1 FIE LO. Io1e# f ,
Depth from Soil Horizon Soil Texture. Soil Color Soil Other
Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulderes.
Consistency.°o rave
oo\
5 SO
'—VIA 10 e 6 /
DEEF OB�ER.'�ATZON HOLE L+D� Hole#
Depth from Soil Horizon Soil Texture Soil Color Soil Other
Surface(in.) (USDA) (Munsell) Mottling. (Structure,Stones,Boulderes.
Consistency.YQ Gravel)
F J
3
oy2 6
toy
DEE$ OBSER�A,TItyN I�(�LE LAC Hole
Depth from Soil Horizon Soil Texture Soil Color Soil Other
Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulderes.
Consistency,Y9 Gravel)
DEEP OBSER��;TION HOLE LL�G Hoxe
Depth from Soil Horizon Soil Texture Soil Color Soil Other
Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulderes.
Consistency.°o ravel
_ Flood Insurance Rate Map:
Above 500 year flood boundary No_ Yes
Within 500 year boundary No Yes
Within 100 year flood boundary No_ Yes
Depth of Naturally Occurring Pervious Material
Does at least four feet of naturally occurring pervious material exist in all areas observed throughout the
area proposed for-the soil absorption system? Y$S
If not,what is the depth of naturally occurring pervious material?
Certification
I certify that on 4 (date)I have passed the soil evaluator examination approved by the
Department of Environmental Protection and that the above analysis was performed by me consistent with
the required traiailpertise and experie described in 310 CMR 15.017*.
Signature Date �00