Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0035 BRANDYWYNE COURT - Health
35 Brandywyne Court Cotuit P A 056 051 j LOCATIONS SEWAGE PERMIT NO. VILLAGE r INSTA LLER'S NAME i ADDRESS - IUILDER OR OWNER DATE PERMIT ISSUED �z _80 DATE COMPLIANCE ISSUED _3 �� �� ��`�, �� W �c � � �r. �^ � � 0� ��' °� ,, ....G6 Fz$....�Jd. ..... THE COMMONWEALTH.OF MASSACHUSETTS NOISSIM03 / BOARD F H TH r,, _°.7:d3SN03 318VISi,ei*J8 ........... .................O F... ..................................-----------------•---....----....................... Appliraiion for Disposal Marks Tonstrnrtinn Vrrmit Application is hereby made for a Permit to Construct ( or Rep it ( ) an Individual Sewage Disposal System at /7 - - �--- ------------------- ..... Locatrpl Add,e r t No. W .......... ......... oO . ................................... ?^ !�!'Y.. Address._......_........ ._......._.. .... ....................... Installer Address Type of Building Size Lot............................Sq.'feet U Dwelling—No. of Bedrooms........... ............................Expansion Attic ( Garbage Grinder (N� a'4 Other—T e of Building No. of persons............................ Showers Other—Type g ---------•-----------•--•--• P ( — Cafeteria ( ) dOther fi ures .----•------------------•----..._...-------------------•-•-•------•-------•••••------•-...•-......................................................... Design Flow.............. ....................gallons per person per day. Total daily flow............ ...................gallons. W ' WSeptic Tank—Liquid capacity... .gallons Length................ Width................ Diameter................ Depth................ x Disposal Trench—No..................... Width.`_........._._._.. Total Length.....................Total leaching area.................... ft. Seepage Pit No..�:!'2-__.__.. Diameter....,O___._...... Depth below inlet.......(z�........ Total leaching area....2:�...sq. ft. Z Other Distribution box ( ) Dosing nnkk�( `-' Percolation Test Results Performed by.......� ---� - ---•------------------------ Date---���'------....--•-- a Test Pit No. 1................minutes per inch Depth of Test Pit.................... Depth to ground water........................ 44 Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ O - �_ " � o Description of Soil..... -Z.._ .... !i Klf1'-L�..... .............................................................. ............. V ........................... -----•-- --------------------- �. _ W UNature of Repairs or Alterations—Answer when applicable................................................................................................ - ...----•--------------•-------..._...-•--------------------------------•--•-•------....---....---•----•---.....------------------------------......-----...--------•---------••----.........---------- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Sanitary o — The der •gned further agrees not to place the system in operation until a Certificate of Compliance has b sued y t rd of health. S -------------7------------- ---•--------------------------•--- ....../ ------------------- D Application Approved By........ ,/....... .. . .. l`/' � -- --------- Date Application Disapproved for the following reasons:............................................................................ ------•-------. .............. --.......-•---•------•-----------------------------------•-----...--•--.....-----•---------.........------••--•-•------•--------------•----............................................................ Date PermitNo......................................................_. Issued...................................................... - Date -S6 FEB........:'.. ... ... THE COMMONWEALTH OF MASSACHUSETTS BOARP/)OF H ...........................................OF.AP .............................................................. J i Appliration for Bhiposal Works Tonotrurtion Prruat Application is hereby made for a Permit to Construct oram Rep, it an Individual Sewage Disposal S..y.s.t..e.m. at a7 & oo& . ..... aoo_7 ...... ..... . ............... ...................... oca r No. t ...................... I.............................................. .......... .. ... r Address Zi .. ........ ....... .......Installer Address ........... ........................ ."�.......................................... �4 U Type of Building Size Lot............................Sq. feet Dwelling—No. of Bedrooms........;. -----_--_---------------Expansion-Attic Garbage Grinder (460 14 aOther—Type of Building .......................... No. of persons.......................... Showers Cafeteria Otherft&tures ................................................. -----------*------------;`1........................................................................ ..5 Design Flow............. .....................gallons per person per day. Tota"I daily flow............1&0...................gallons. WSeptic Tank—Liquid capacity./00.gallons Length................. Width................. Diameter-..,:_-......... Depth................ Disposal Trench—No..................... Width...........---..... Total Length---.........I....... Total leaching area.....- ...........sq. f t. Seepage Pit No../.4-Z-------- Diameter....IT........... Depth below inlet._.....___:____. Total leaching area...... ........... q. ft. Z Other Distribution box Dosing 4n1k 0-4 i i 0 -1 /9 _y __ - Percolation Test Results Performed by ......A44. .Zl... Date...o�.�............................ �-1 --------------------*... -1 Test Pit No. I................minutes per inch Depth of Test Pit.--.--....._........ Depth to ground water.--...........--........ P� Test Pit No. 2................minutes per inch Depth of Test Pit---...........--_... Depth to ground water:............_......---. Pd 4,T; ...............------------------ *'...................................................... ......... 4. ......... . .. ........ 0 Description of Soil..... ..............w................ ................... . ........................................................................... ------------- .............................................. ......................................................................................................................................................... U Nature of Repairs or Alterations--Answer when applicable.---............................................................................................ ............................................. .............................................................................. Agreement: The undersigned a.grees to install the aforedescribed' Individual Sewage Disposal System in accordance with the provisions of T I T TIE 5 of the State Sanitary o —Th� nde igned further',agrees not to place the system in operation until a Certificate of YCompliance has b sue tj.fe oard of health. . ........... ....... ........t .................................... .............................. D ApplicationApproved By-------. .... . ......... .. ....... ..... .... . ..... ................ ........... ............. ........ ............ Date Application Disapproved for the following reasons:.......................................I...--_.._.._.............................................................. ...........................7.......................................................................................................................................................................... Date PermitNo......................................................... Issued_....................................................... Date THE COMMONWEALTH OF MASSACHUSETTS BOAR OF HFiALX�1 ........A,771.................OF...10A.444 ................ .............. THIS IS T;�K�ERTIFY, TR/the/ by.......... )Individual Sewage Disposal System constructed (I--�®r Repaired ------------------------------------------------------------------- ................. at..........4�.................................... ............................................................................................................................... ........... P -- ') of h has been instilled in accordance with the provisions of TZT.L_ I State Sanitary Code as described in the application for Disposal Works Construction Permit No(_F C - ......... dated.............:.................................... _ --------- THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GUARANTEE THAT THE SYSTEM WILL FUNCTION SATISFACTORY. pi DATE.. .7........P.Z.. .................................. Inspector....... .................................. ...................................... THE COMMONWEALTH OF MASSACHUSETTS BOARD) ADF HEA T�*6 .. ......... 6. .................................... OF........... 0 ........... FEE..._.................... ](-1 Dispos Modg no ion Vamit Permission is 3hgreby granted.—.----t tul........................ ................. ............... .......................................................... to Construct XCF Individu Se} �eDisposal stem atNo.................................. ......................................y------------------------- Street as shown on the application for Disposal Works Construct' I No.__-----------_---- a ed------------ a a f- Health .......... ., aii DATE............................................................................... FORM 1255 HOBBS & WARREN, INC.. PUBLISHERS COMMONWEALTH OF MASSACHUSETTS W EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS + d DEPARTMENT OF ENVIRONMENTAL PROTECTION �qM SV0 ,m 350 MAIN STREET A WEST YARMOUTH,MA 508-775-2800 TITLE 5 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM PART A CERTIFICATION MAP 056 PAR 051 Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner's Name: STEMBRIDGE,KOREN Owner's Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Date of Inspection MARCH 29,2004 Name of Inspector:(please print) JAMES D. SEARS Company Name: A&B Canco Mailing Address: 350 Main Street West Yarmouth,MA.02673 Telephone Number: 508-775-2800 CERTIFICATION STATEMENT I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true,accurate and complete as of the time of the inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000). The system: ./ Passes Conditionally Passes Needs Further Evaluation by the Local Approving Authority Fails Inspector's Signature: Date: The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent tot he buyer,if applicable,and the approving authority. Notes and Comments REPORT ONE OF TWO—SYSTEM#1 ""This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. Title 5 Inspection Form 6/15/2000 1 Page 2 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 Inspection Summary: Check A,B,C,D or E/ALWAYS complete all of Section D A. System Passes: ./ _ I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: B. System Conditionally Passes: N/A One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The system,upon completion of the replacement or repair,as approved by the Board of Health,will pass. Answer yes,no or not determined(Y,N,ND)in the for the following statements. If"not determined" please explain. _ The septic tank is metal and over 20 years old*or the septic tank(whether metal or not)is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will.pass inspection if the existing tank is replaced with complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ND explain: Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken,settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced ND explain: _ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health)" broken pipe(s)are replaced obstruction is removed ND explain: Title 5 Inspection Form 6/15/2000 2 Page 3 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(CONTINUED) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 C. Further Evaluation is Required by the Board of Health: N/A Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health,safety,or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health safety and the environment: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or salt marsh 2. System will fail unless the Board of Health(and Public Water Supplier,if any)determines that the system is functioning in a manner that protects the public health,safety and environment: The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and SAS and the SAS is within a Zone 1 of public water supply. The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance **This system passes if the well water analysis,performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: Title 5 Inspection Form 6/15/2000 3 Page 4 of 1 1 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(CONTINUED) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 D. System Failure Criteria applicable to all systems: N/A You must indicate"yes"or"no"to each of the following for all inspections: Yes No ✓ Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ✓ Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ✓ Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ✓ Liquid depth in pit is less than 6"below invert or available volume is less than''/z day flow ✓ Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped ✓ Any portion of the SAS,cesspool or privy is below high ground water elevation N/A Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply N/A Any portion of a cesspool or privy is within a Zone 1 of a public well N/A Any portion of a cesspool or privy is within 50 feet of a private water supply well N/A Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. (This system passes if the well water analysis performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form.) NO (Yes/No)The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact " the Board of Health to detennine what will be necessary to correct the failure. E. Large Systems: N/A To be considered a large system the system must service a facility with a design flow of 10,000 gpd to 15,000 gpd. You must indicate either"yes"or"no to each of the following: (The following criteria apply to large systems in addition to the criteria above) Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area—IWPA)or a mapped Zone II of a public water supply well.. If you have answered"yes"to any question in Section E the system is considered a significant threat,or answered "yes"in Section D above the large system is failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. Title 5 Inspection Form 6/15/2000 4 Page 5 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 Check if the following have been done. You must indicate"yes"or"no"as to each of the following Yes No ✓ Pumping information was provided by the owner,occupant,or Board of Health J Were an of the system components y y p is pumped out in the previous two weeks. ✓ Has the system received normal flows in the previous two week period? ✓ Have large volumes of water been introduced to the system recently or as part of this inspection? ✓ Were as built plans of the system obtained and examined?(If they were not available note as N/A) J Was the facility or dwelling inspected for signs of sewage back up? J Was the site inspected for signs of break out? ✓ Were all system components,excluding the SAS,located on site? ✓ Were the septic tank manholes uncovered,opened,and the interior of the tank inspected for the condition of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum If Was the facility owner(and occupants if different from owner)provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System(SAS)has been determined based on: Yes No ✓ Existing information. For example,a plan at the Board of Health. ✓ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable)[310 CMR 15.302(3)(b)] r Title 5 Inspection Form 6/15/2000 5 Page 6 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address:. 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 FLOW CONDITIONS RESIDENTIAL Number of Bedrooms(design): 4 Number of bedrooms(actual): 4 DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms: 440 Number of current residents: 3 Does residence have a garbage grinder(yes or no): YES Is laundry on a separate sewage system(yes or no): NO [if yes separate inspection required] Laundry system inspected(yes or no): YES Seasonal use(yes or no): NO Water meter readings,if available(last 2 years usage(gpd)): N/A Sump pump(yes or no) NO Last date of occupancy: PRESENT COMMERCIAL/INDUSTRIAL Type of establishment: Design flow(based on 310 CMR 15.203): Basis of design flow(seats/persons/sqft,etc.): Grease trap present(yes or no): Industrial waste holding tank present(yes or no): Non-sanitary waste discharged to the Title 5 system(yes or no): Water meter readings,if available: Last date of occupancy/use: OTHER(describe): GENERAL INFORMATION Pumping Records Source of information: 2000 Was system pumped as part of the inspection(yes or no): NO If yes,volume pumped: gallons—How was quantity pumped determined? Reason for pumping: TYPE OF SYSTEM ./ Septic tank,distribution box,soil absorption system Single cesspool Overflow cesspool Privy Shared system(yes or no)(if yes,attach previous inspection records,if any) Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) Tight tank Attach copy of the DEP approval Other(describe): Approximate age of all components,date installed(if known)and source of information: 1980 Were sewage odors detected when arriving at the site(yes or no): NO Title 5 Inspection Form 6/15/2000 6 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 BUILDING SEWER(locate on site plan): N/A Depth below grade: Materials of construction: Cast iron _ 40 PVC _ other(explain) Distance from private water supply well or suction line: Comments(on condition of joints,venting,evidence of leakage,etc.): SEPTIC TANK(locate onsite plan): ./ Depth below grade: 26" Material of construction: ✓ concrete metal fiberglass polyethylene _ other(explain) If tank is metal list age: Is age confirmed by a Certificate of Compliance(yes or no): (attach a copy of certificate) Dimensions: 1,000 GALLON PRE CAST Sludge depth: 2" Distance from top of sludge to the bottom of outlet tee or baffle: 28" Scum thickness: 1" Distance from top of scum to top of outlet tee or baffle: 12" Distance from bottom of scum to bottom of outlet tee or baffle: 17" How were dimensions determined: ASBUILT,TAPE AND PAST REPORT Comments(on pumping recommendations,inlet and-outlet tee or baffle condition,structural integrity,liquid levels as related to outlet invert,evidence of leakage,etc.): MAIN TANK AT WORKING LEVEL.INLET TEE,OUTLET BAFFLE.INLET COVER AT GRADE.NO SIGN OF OVERLOADING OR LEAKAGE. GREASE TRAP(located on site plan) N/A Depth below grade: Material of construction: concrete metal fiberglass _ polyethylene other (explain): Dimensions: Scum thickness: Distance from top of scum to top of outlet tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle: Date of last pumping: Comments(on pumping recommendations,inlet and outlet tee or baffle condition,structural integrity,liquid levels as related to outlet invert,evidence of leakage,etc.): Title 5 Inspection Form 6/15/2000 7 Page 8 of 1 1 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 TIGHT or HOLDING TANK: N/A (tank must be pumped at time of inspection)(locate on site plan) Depth below grade: Material of construction: concrete metal fiberglass polyethylene other(explain) Dimensions: Capacity: gallons Design Flow: gallons/day Alarm present(yes or no) Alarm level: Alarm in working order(yes or no): Date of last pumping Comments(condition of alarm and float switches,etc.): DISTRIBUTION BOX: ./ (if present must be opened)(locate on site plan) Depth of liquid level above outlet invert: 0 Comments(note if box is level and distribution to outlets equal,any evidence of solids carryover,any evidence of leakage into or out of box,etc.,): DISTRIBUTION BOX IS 9"x15",32"BELOW GRADE. BOX IS CLEAN.ONE LINE OUT. NO SIGN OF OVERLOADING OR SOLID CARRYOVER. PUMP CHAMBER: N/A (locate on site plan) Pumps in working order(yes or no): Alarms in working order(yes or no): Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.): Title 5 Inspection Form 6/15/2000 8 I Page 9 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 SOIL ABSORPTION SYSTEM(SAS): ✓ (locate on site plan,excavation not required) If SAS not located explain why: Type ./ leaching pits,number: 1 leaching chambers,number: leaching galleries,number leaching trenches,number,length leaching fields,number,dimensions: overflow cesspool,number: innovative/alternative system Type/name of technology: Comments(note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.) LEACHING IS ONE 4'PRE CAST PIT.PIT IS 3' BELOW GRADE WITH COVER AT 6".3'TO WATER. I' WATER IN PIT.NO HIGH STAIN LINE.NO SIGN OF OVERLOADING OR SOLID CARRYOVER. CESSPOOLS: N/A (cesspool must be pumped as part of inspection)(locate on site plan) Number and configuration: Depth—top of liquid to inlet invert: Depth of solids layer: Depth of scum layer: Dimensions of cesspool: Materials of construction: Indication of groundwater inflow(yes or no): Comments(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation etc.): PRIVY: N/A (locate on site plan) Materials of Construction: Dimensions: Depth of solids: Comments(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.) Title 5 Inspection Form 6/15/2000 9 Page 10 of 1 1 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: . STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 SKETCH OF SEWAGE DISPOSAL SYSTEM Provide.a sketch of the sewage disposal system including ties to at least two pennanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. 57/ 1 G ! 5� Title 5 Inspection Form 6/15/2000 10 I Page 1 1 of 1 1 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 SITE EXAM Slope Surface water Check cellar Shallow wells Estimated depth to no groundwater 12 feet Please indicate(check)all methods used to determine the high ground water elevation: Obtained from system design plans on record-If checked,date of design plan reviewed: ./ Observation site(abutting property/observation hole within 150 feet of SAS) Checked with local Board of Health-explain: Checked with local excavators,installers-(attach documentation Accessed USGS database-explain: You must describe how you established the1igh ground water elevation: TEST HOLE NOTED ON PAGE 10.TEST HOLE 12'BELOW GRADE. TEST HOLE 4' BELOW BOTTOM OF PIT. 1 C. Title 5 Inspection Form 6/15/2000 11 w 15 3 COMMONWEALTH OF MASSACHUSETTS f EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS Y m d DEPARTMENT OF ENVIRONMENTAL PROTECTION a ' r iegM s�av 350 MAIN STREETAAP WEST YARMOUTH,MA PARCH � O 508-775-2800 LOT TITLE 5 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM PART A RECEIVED CERTIFICATION MAP 056 PAR 051 Property Address: 35 BRANDY WINE COURT - APR 1 6 2004 COTUIT,MA 02635 Owner's Name: STEMBRIDGE,KOREN TOWN OF BARNSTABLE Owner's Address: 35 BRANDY WINE COURT HEALTH DEPT. COTUIT,MA 02635 Date of Inspection MARCH 29,2004 Name of Inspector:(please print) JAMES D. SEARS Company Name: A&B Canco Mailing Address: 350 Main Street West Yannouth,MA 02673 Telephone Number: 508-775-2800 CERTIFICATION STATEMENT I certify that I have personally inspected the sewage disposal system at this address and that the infonnation reported below is true,accurate and complete as of the time of the inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000). The system: ✓ Passes Conditionally Passes Needs Further Evaluation by the Local Approving Authority Fails Inspector's Signature: Date: -y The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent tot he buyer,if applicable,and the approving authority. Notes and Comments REPORT TWO OF TWO—SYSTEM#2 ****This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. Title 5 Inspection Form 6/15/2000 1 Page 2 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 Inspection Summary: Check A,B,C,D or E/ALWAYS complete all of Section D A. System Passes: ✓ I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: B. System Conditionally Passes: N/A One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The system,upon completion of the replacement or repair,as approved by the Board of Health,will pass. Answer yes,no or not determined(Y,N,ND)in the for the following statements. If"not determined" please explain. The septic tank is metal and over 20 years old*or the septic tank(whether metal or not)is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ND explain: Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken,settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced ND explain: The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health)" broken pipe(s)are replaced obstruction is removed ND explain: Title 5 Inspection Form 6/15/2000 2 Page 3 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(CONTINUED) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 C. Further Evaluation is Required by the Board of Health: N/A Conditions exist which require further evaluation by the Board of Health in order to detennine if the system is failing to protect public health,safety,or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health safety and the environment: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or salt marsh 2. System will fail unless the Board of Health(and Public Water Supplier,if any)determines that the system is functioning in a manner that protects the public health,safety and environment: The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and SAS and the SAS is within a Zone 1 of public water supply. The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance **This system passes if the well water analysis,performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: Title 5 Inspection Form 6/15/2000 3 Page 4 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(CONTINUED) Ih Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 D. System Failure Criteria applicable to all systems: N/A You must indicate"yes"or"no"to each of the following for all inspections: Yes No ✓ Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ✓ Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ✓ Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ✓ Liquid depth in pit is less than 6"below invert or available volume is less than'/z day flow ✓ Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped ✓ Any portion of the SAS,cesspool or privy is below high ground water elevation N/A Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply N/A Any portion of a cesspool or privy is within a Zone 1 of a public well N/A Any portion of a cesspool or privy is within 50 feet of a private water supply well N/A Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. (This system passes if the well water analysis performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form.) NO (Yes/No)The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E. Large Systems: N/A To be considered a large system the system must service a facility with a design flow of 10,000 gpd to 15,000 gpd. You must indicate either"yes"or"no to each of the following: (The following criteria apply to large systems in addition to the criteria above) Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area—IWPA)or a mapped Zone II of a public water supply well. If you have answered"yes"to any question in Section E the system is considered a significant threat,or answered "yes"in Section D above the large system is failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. Title 5 Inspection Form 6/15/2000 4 Page 5 of 1 I OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 Check if the following have been done. You must indicate"yes"or"no"as to each of the following Yes No ✓ Pumping infonnation was provided by the owner,occupant,or Board of Health ./ Were any of the system components pumped out in the previous two weeks? ✓ Has the system received nonnal flows in the previous two week period? ✓ Have large volumes of water been introduced to the system recently or as part of this inspection? ✓ Were as built plans of the system obtained and examined?(If they were not available note as N/A) ✓ Was the facility or dwelling inspected for signs of sewage back up? ✓ Was the site inspected for signs of break out? ✓ Were all system components,excluding the SAS,located on site? ✓ Were the septic tank manholes uncovered,opened,and the interior of the tank inspected for the condition of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum ✓ Was the facility owner(and occupants if different from owner)provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System(SAS)has been determined based on: Yes No ✓ Existing information. For example,a plan at the Board of Health. ✓ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable)[310 CMR 15.302(3)(b)] Title 5 Inspection Form 6/15/2000 5 Page 6 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 FLOW CONDITIONS RESIDENTIAL Number of Bedrooms(design): 4 Number of bedrooms(actual): 4 DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms: 440 Number of current residents: 3 Does residence have a garbage grinder(yes or no): YES Is laundry on a separate sewage system(yes or no): NO [if yes separate inspection required] Laundry system inspected(yes or no): YES Seasonal use(yes or no): NO Water meter readings,if available(last 2 years usage(gpd)): N/A Sump pump(yes or no) NO Last date of occupancy: PRESENT COMMERCIAL/INDUSTRIAL Type of establishment: Design flow(based on 310 CMR 15.203): Basis of design flow(seats/persons/sqft,etc.): Grease trap present(yes or no): Industrial waste holding tank present(yes or no): Non-sanitary waste discharged to the Title 5 system(yes or no): Water meter readings,if available: Last date of occupancy/use: OTHER(describe): GENERAL INFORMATION Pumping Records Source of information: 2000 Was system pumped as part of the inspection(yes or no): NO If yes,volume pumped: gallons—How was quantity pumped determined? Reason for pumping: TYPE OF SYSTEM ./ Septic tank,distribution box,soil absorption system Single cesspool Overflow cesspool Privy Shared system(yes or no)(if yes,attach previous inspection records,if any) Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) Tight tank Attach copy of the DEP approval Other(describe): Approximate age of all components,date installed(if known)and source of information: 1908 Were sewage odors detected when arriving at the site(yes or no): NO Title 5 Inspection Form 6/15/2000 6 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 BUILDING SEWER(locate on site plan): N/A Depth below grade: Materials of construction: Cast iron _ 40 PVC _ other(explain) Distance from private water supply well or suction line: Comments(on condition of joints,venting,evidence of leakage,etc.): SEPTIC TANK(locate onsite plan): ✓ Depth below grade: 20" Material of construction: ✓ concrete metal fiberglass polyethylene _ other(explain) If tank is metal list age: Is age confirmed by a Certificate of Compliance(yes or no): (attach a copy of certificate) Dimensions: 1,000 GALLON PRE CAST Sludge depth: F, Distance from top of sludge to the bottom of outlet tee or baffle: 29" Scum thickness: 0" Distance from top of scum to top of outlet tee or baffle: 12" Distance from bottom of scum to bottom of outlet tee or baffle: 18" How were dimensions detennined: ASBUILT,TAPE AND PAST REPORT Comments(on pumping recommendations,inlet and outlet tee or baffle condition,structural integrity,liquid levels as related to outlet invert,evidence of leakage,etc.): MAIN TANK AT WORKING LEVEL.OUTLET BAFFLE.TANK AND COVERS 20"BELOW GRADE.NO SIGN OF OVERLOADING OR LEAKAGE. GREASE TRAP(located on site plan) N/A Depth below grade: Material of construction: concrete metal fiberglass _ polyethylene other (explain): Dimensions: Scum thickness: Distance from top of scum to top of outlet tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle: Date of last pumping: Comments(on pumping recommendations,inlet and outlet tee or baffle condition,structural integrity,liquid levels as related to outlet invert,evidence of leakage,etc.): Title 5 Inspection Form 6/15/2000 7 I Page 8 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 TIGHT or HOLDING TANK: N/A (tank must be pumped at time of inspection)(locate on site plan) Depth below grade: Material of construction: concrete metal fiberglass polyethylene other(explain) Dimensions: Capacity: gallons Design Flow: gallons/day Alarm present(yes or no) Alarm level: Alarm in working order(yes or no): Date of last pumping Comments(condition of alarm and float switches,etc.): DISTRIBUTION BOX: ✓ (if present must be opened)(locate on site plan) Depth of liquid level above outlet invert: 0 Comments(note if box is level and distribution to outlets equal,any evidence of solids carryover,any evidence of leakage into or out of box,etc.,): DISTRIBUTION BOX IS 16"x16",29"BELOW GRADE.ONE LINE IN,ONE LINE OUT. BOX IS CLEAN.NO SIGN OF OVERLOADING OR SOLID CARRYOVER. PUMP CHAMBER: N/A (locate on site plan) Pumps in working order(yes or no): Alarms in working order(yes or no): Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.): Title 5 Inspection Form 6/15/2000 8 Page 9 of]1 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 SOIL ABSORPTION SYSTEM(SAS): ✓ (locate on site plan,excavation not required) If SAS not located explain why: Type ✓ leaching pits,number: 1 leaching chambers,number: leaching galleries,number leaching trenches,number,length leaching fields,number,dimensions: overflow cesspool,number: innovative/alternative system Type/name of technology: Comments(note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.) LEACHING IS ONE 1,000 GALLON PRE CAST PIT.PIT AND COVER 20"BELOW GRADE.6"WATER IN PIT. STAIN LINE AT 1'.NO SIGN OF OVERLOADING OR SOLID CARRYOVER. CESSPOOLS: N/A (cesspool must be pumped as part of inspection)(locate on site plan) Number and configuration: Depth—top of liquid to inlet invert: Depth of solids layer: Depth of scum layer: Dimensions of cesspool: Materials of construction: Indication of groundwater inflow(yes or no): Comments(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation etc.): PRIVY: N/A (locate on site plan) Materials of Construction: Dimensions: Depth of solids: Comments(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.) Title 5 Inspection Form 6/15/2000 9 Page 10 of 1 I OFFICL4L INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 SKETCH OF SEWAGE DISPOSAL SYSTEM Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building: . I ,t r � G r- S ✓5 j r�+ 1- Title 5 Inspection Fo-.6/15/2000 10 Pate Hof 1 1 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT COTUIT,MA 02635 Owner: STEMBRIDGE,KOREN Date of Inspection: MARCH 29,2004 SITE EXAM Slope Surface water Check cellar Shallow wells Estimated depth to no groundwater 12 feet . Please indicate(check)all methods used to detennine the high ground water elevation:. Obtained from system design plans on record-If checked,date of design plan reviewed: ./ Observation site(abuttingproperty/observation hole within 150 feet of.SAS) . - - Checked with local Board of Health-explain: Checked with local excavators,installers-(attach documentation Accessed USGS database-explain: You must describe how you established the high ground water elevation: TEST HOLE NOTED ON PAGE 10.NO WATER AT 12'. BOTTOM OF PIT 4'ABOVE TEST HOLE. { i3"N K iv,4 Title 5 Inspection Form 6/15/2000 11 _ -- LOMMONWEAL'I'll OF MASSACIIUSETTS a � EXECUTIVE OFFICE OF ENVIRONMENTAL A.F IR - DEPAR'I'M.ENT OF ENVI110NMT;N rAt, I'RO'1' TION ONE WINTER STREET, IIOS'I'ON MA 02109 (617) 292-fifi0t) 4410 0� 2000RU �1Q,OXE 350 MAIN STREET A(1}� � eFreL.ry ARGEO PAUL CELLUCCI WEST YARMOUTH, MA DAVI,DiT3 19TRUIIS Governor 508-775-2800 {; innussioner SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION MAP 056 PAR 051 PROPERTY ADDRESS: 35 BRANDY WINE COURT, COTUIT ADDRESS OF OWNER: DATE OF INSPECTION: APRIL 21, 2000 STERLING BUSH NAME OF INSPECTOR : JAMES D. SEARS I am a DEP approved system inspector pursuant to Section 15.340 of Title 5 9310 CMR 15.000) COMPANY NAME: A&B Canco MAILING ADDRESS: 350 Main Street,West Yarmouth,MA 02673 TELEPHONE NUMBER: (508)775-2800 CERTIFICATION STATEMENT I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate and complete as of the time of inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. The system: X PASSES CONDITIONALLY PASSES NEEDS FURTHER EVALUATION BY THE LOCAL APPROVING AUTHORITY FAILS INSPECTORS SIGNATURE: DATE: MAY 1,2000 The system Inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP) within thirty(30) days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the Department of Environmental Protection. The original should be sent to the system owner and copies sent to the buyer,if applicable and the approving authority. NOTES AND COMMENTS: SITE OVER ALL PASSES,INSPECTION OF SYSTEM IS BASED ON CONDITION OF SYSTEM AT THE TIME OF THE INSPECTION.THERE IS NO GUARANTEE ON THE LIFE OF THE SYSTEM. NOTE: REPORT ONE OF TWO (TWO SYSTEMS) revised 9/2/98 1 ' SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 35 BRANDY WINE COURT,COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 INSPECTION SUMMARY: Check A,B, C, orD: A] SYSTEM PASSES: X I have not found any information which indicates that the system violates any of the failure criteria as defined in 310 CMR 15.303. Any failure criteria not evaluated are indicated below. COMMENTS: B SYSTEM CONDITIONALLY PASSES: N/A One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The System,upon completion of the replacement or repair,as approved by the Board of Health will pass. Indicate yes,no,or not determined(Y,N,or ND). Describe basis of determination in all instances. If"not determined",explain why not) _ The septic tank is metal,unless the owner or operator has provided the system inspector with a copy of a Certificate Of Compliance(attached)indicating that the tank was installed within twenty(20) years prior to the date of the inspection;or the septic tank,whether or not metal,is cracked,structurally unsound,shows substantial infiltration or exfiltration,or tank is failure is imminent. The system will pass inspection if the existing septic tank is replaced with a conforming septic tank as approved by the Board of Health. S Sewage backup or breakout or high static water level observed in the distribution box is due to broken or obstructed pipe(s)or due to a broken,settled or uneven distribution box. The system will pa pass inspection if(with approval of the Board of Health). broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced _ The system required pumping more than four times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed revised 9/2/98 2 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH, STERLING Date of Inspection: APRIL 21,2000 C] FURTHER EVALUATION IS REQUIRED BY THE BOARD OF HEALTH: N/A Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect the public health,safety and the environment. 1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES IN ACCORDANCE WITH 310 CMR 15.303 (1)(b)THT THE SYSTEM IS NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh. 2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH(AND PUBLIC WATER SUPPLIER,IF ANY) DETERMINES THAT THE SYSTEM IS FUNCTIONING IN A MANNER THAT PROTECTS THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT: The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and soil absorption system and the SAS is within a Zone 1 of a public water supply well. The system has a septic tank and soil absorption system and the SAS is within 50 feet of a private water supply well. The system has a septic tank and soil absorption system and the SAS is less than 100 feet but 50 feet or more from a private water supply well,unless a well water analysis for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen and is equal to or less than 5 ppm. Method used to determine distance (approximation not valid). 3) OTHER revised 9/2/98 3 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 D]SYSTEM FAILS: N/A You must indicate either"Yes"or"No" to each of the following: I have determined that one or more of the following failure conditions exist as described in 310 CMR 16.303. The basis for this determination is identified below. The Board of Health should be contacted to Determine what will be necessary to correct the failure. Yes No Backup of sewage into facility or system component due to an overloaded or clogged SAS or cesspool. Discharge or ponding of effluent to the surface of the ground or surface waters due to an over- loaded or clogged SAS or cesspool. Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool. Liquid depth in cesspool is less than 6"below invert or available volume is less than%day flow Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s) Number of times pumped Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater elevation. Any portion of a cesspool or privy is within 100 feet of surface water supply or tributary to a surface water supply. Any portion of a cesspool or privy is within a Zone I of a public well. Any portion of a cesspool or privy is within 50 feet of a private water supply well. Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. If the well has been analyzed to be acceptable,attach copy of well water analysis for coliform bacteria,volatile organic compounds,ammonia nitrogen and nitrate nitrogen. E) LARGE SYSTEM FAILS: N/A You must indicate either"Yes"or"No"as to each of the following: The following criteria apply to large systems in addition to the criteria above: The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a significant threat to public health and safety and the environment because one or more of the following conditions exist: Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or mapped Zone II of a public water supply well) The owner or operator of any such system shall upgrade the system in accordance with 310 CMR 15.304(2). Please consult the local regional office of the Department for further information. revised 9/2/98 4 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 Check if the following have been done:You must indicate either"Yes"or"No"as to each of the following: Yes No X Pumping information was provided by the owner,occupant,or Board of Health. X None of the system components have been pumped for at least two weeks and the system has been receiving normal flow rates during that period. Large volumes of water have not been introduced into the system recently or as part of this inspection. X As built plans have been obtained and examined. Note if they are not available with N/A. X The facility or dwelling was inspected for signs of sewage back-up. X The system does not receive non-sanitary or industrial waste flow. X The site was inspected for signs of breakout. X All system components,including the Soil Absorption System,have been located on the site. X The septic tank manholes were uncovered,opened,and the interior of the septic tank was inspected for condition of baffles or tees,material of construction,dimensions,depth of liquid depth of sludge,depth of scum. The size and location of the Soil Absorption System on the site Has been determined based on: X Existing information.Ex.Plan at B.O.H. X Determined in the field(if any of the failure criteria related to Part C is at issue,approximation of distance is unacceptable)[15.302(3)(b)] X The facility owner(and occupants,if different from owner)were provided with information on the proper maintenance of Sub-Surface Disposal System. revised 9/2/98 5 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 35 BRANDY WINE COURT,COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 FLOW CONDITIONS RESIDENTIAL: Design flow: 440 g.p.d./bedroom for S.A.S. Number of bedrooms(design) 4 Number of bedrooms(actual): 4 Total DESIGN flow N/A Number of current residents: 3 Garbage grinder(yes or no): YES Laundry(separate system) (yes or no): NO If yes,separate inspection required Laundry system inspected(yes or no): YES Seasonal use(yes or no) NO Water meter readings,if available(last two(2)year usage(gpd): 1999 71,000!1998 89,000 Sump Pump(yes or no): NO Last date of occupancy: N/A COM M ERCIAL/I NDUSTRIAL: Type of establishment: Design flow: Gpd(Based on 16.203) Basis of design flow Grease trap present:(yes or no): Industrial Waste Holding Tank present:(yes or no) Non-sanitary waste discharged to the Title 5 system:(yes or no) Water meter readings,if available: Last date of occupancy: OTHER:(Describe) Last date of occupancy: GENERAL INFORMATION PUMPING RECORDS and source of information: N/A System pumped as part of inspection:(yes or no) NO If yes,volume pumped: gallons Reason for pumping TYPE OF SYSTEM X Septic tank/distribution boxisoil absorption system Single cesspool Overflow cesspool Privy Shared system(yes or no)(if yes,attach previous inspection records,if any) I/A Technology etc.Attach copy of up to date operation and maintenance contract. Tight Tank Copy of DEP Approval Other APPROXIMATE AGE of all components, date installed(if known)and source of information: 1980 Sewage odors detected when arriving at the site:(yes or no) NO revised 9/2/98 6 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 35 BRANDY WINE COURT,COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 BUILDING SEWER: N/A (Locate on site plan) Depth below grade: Material of construction _ cast iron _ 40 PVC _ other(explain) Distance from private water supply well or suction line Diameter Comments:(condition of joints,venting,evidence of leakage,etc.) SEPTIC TANK: X (Locate on site plan) Depth below grade: 26" Material of construction X concrete _ metal _ Fiberglass _ Polyethylene _ other(explain) If tank is metal,list age Is age confirmed by Certificate of Compliance (Yes/No) Dimensions: 1,000 GALLON Sludge depth: 41 Distance from top of sludge to bottom of outlet tee or baffle: 26" Scum thickness: 1" Distance from top of scum to top of outlet tee or baffle: 12" Distance from bottom of scum to bottom of outlet tee or baffle: 17" How dimensions were determined ASBUILT AND TAPE Comments: (recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,etc.) MAIN TANK AT WORKING LEVEL,INLET TEE.OUTLET BAFFLE,INLET COVER CEMENT AT GRADE. NOTE: TANK PUMPED AFTER INSPECTION. GREASE TRAP: N/A (locate on site plan) Depth below grade: Material of construction _ concrete _ metal _ Fiberglass _ Polyethylene _ other(explain) Dimensions: Scum thickness: Distance from top of scum to top of outlet tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle: Date of last pumping: Comments: (recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,etc.) revised 9/2/98 7 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 TIGHT OR HOLDING TANK: N/A (Tank must be pumped prior to,or at time,of inspection) (Locate on site plan) Depth below grade: Material of construction _ concrete _ metal _ Fiberglass _ Polyethylene _ other(explain) Dimensions: Capacity: Gallons Design flow: gallons/day Alarm present Alarm level: Alarm in working order Yes; No Date of previous pumping: Comments: (condition of inlet tee,condition of alarm and float switches,etc.) DISTRIBUTION BOX: X (locate on site plan) Depth of liquid level above outlet invert: 0 Comments: (note if level and distribution is equal,evidence of solids carryover,evidence of leakage into or out of box,etc,) D-BOX IS 32"BELOW GRADE,ONE LINE IN,ONE LINE OUT.BOX IS CLEAN AND LEVEL.NO SOLID CARRY OVER. PUMP CHAMBER: N/A (locate on site plan) Pumps in working order:(Yes or No) Alarms in working order(Yes or No) Comments: (note condition of pump chamber,condition of pumps and appurtenances,etc.) I revised 9/2/98 8 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH, STERLING Date of Inspection: APRIL 21, 2000 SOIL ABSORPTION SYSTEM (SAS): X (locate on site plan,if possible;excavation not required,but may be approximated by non-intrusive methods) If not located, explain: Type: Leaching pits,number: 1 Leaching chambers,number: Leaching galleries,number: Leaching trenches,number,length: Leaching fields,number,dimensions: Overflow cesspool,number, Alternative system: Name of Technology: Comments: (note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.) ONE(1)4'PRE CAST PIT,PIT 3'BELOW GRADE.COVER 6"BELOW GRADE.WATER AND STAIN LINE 18"UP WALL. CESSPOOLS: N/A (locate on site plan) Number and configuration: Depth-top of liquid to inlet invert: Depth of solids layer: Depth of scum layer: Dimensions of cesspool: Materials of construction: Indication of groundwater: inflow(cesspool must be pumped as part of inspection) Comments:: (note condition of soil,signs of hydraulic failure, ,level of ponding,condition of vegetation,etc.) PRIVY: N/A (locate on site plan) Materials of construction: Dimensions: Depth of solids: Comments: (note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.) revised 9/2/98 9 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH, STERLING Date of Inspection: APRIL 21, 2000 SKETCH OF SEWAGE DISPOSAL SYSTEM: include ties to at least two permanent references landmarks or benchmarks locate all wells within 100'(locate where public water supply comes into house) /Jlr o v 7 � o \ C/ ° O jf�t s ys J11- j revised 9/2/98 10 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH, STERLING Date of Inspection: APRIL 21, 2000 NRCS Report name Soil Type Typical depth to groundwater USGS Date website visited Observation Wells checked Ground water depth: Shallow Moderate Deep SITE EXAM Slope Surface water Check Cellar Shallow wells Estimated Depth to no groundwater 12 Feet Please indicate all the methods used to determine High Groundwater Elevation: Obtained from Design Plans on record X Observation of Site(Abutting property,observation hole,basement sump etc.) Determine it from local conditions Check with local Board of health Check FEMA Maps Check pumping records Check local excavators,installers Use USGS Data Describe in your own words how you established the High Groundwater Elevation.(Must be completed) TEST HOLE NOTED ON PAGE 10. TEST HOLE 12' BELOW GRADE, 4' BELOW BOTTOM OF PIT. revised 9/2/98 11 - LOMMONWEAL'I'Ii OF MASSACHUSE1I'1'S EXECUTIVE OFFICE OF ENVIRONMENTAL AF A-11RS ► [ DEPARTMENT OF ENVIRONMENTAL PROfE OTION q ` ONE, WINTER STREET, BOSTON MA 02108 (617) 292!55Q0 � w+� 4 4AY V1'Q 2000IT Y COXE ! ?04V I Secretary 350 MAIN STREET -! ARGEO PAUL CELLUCCI WEST YARMOUTH, MA y 1) D: . STRUHS Governor 508-775-2800 l ommissioner d SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM. PART A CERTIFICATION MAP 056 PAR 051 PROPERTY ADDRESS: 35 BRANDY WINE COURT, COTUIT ADDRESS OF.OWNER: DATE OF INSPECTION: APRIL 21, 2000 STERLING BUSH NAME OF INSPECTOR : JAMES D. SEARS I am a DEP approved system inspector pursuant to Section 15.340 of Title 5 9310 CMR 15.000) COMPANY NAME: A&B Canco MAILING ADDRESS: 350 Main Street,West Yarmouth,MA 02673 TELEPHONE NUMBER: (508)775-2800 CERTIFICATION STATEMENT I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate and complete as of the time of inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. The system: X PASSES CONDITIONALLY.PASSES NEEDS FURTHER EVALUATION BY THE LOCAL APPROVING AUTHORITY FAILS INSPECTORS SIGNATURE: _ DATE: MAY 1,2000 The system Inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP) within thirty(30) days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office.of the Department of Environmental Protection. The original should be sent to the system owner and copies sent to the buyer,if applicable and the approving authority. NOTES AND COMMENTS: SITE OVER ALL PASSES,INSPECTION OF SYSTEM IS BASED ON CONDITION OF SYSTEM AT THE TIME OF THE INSPECTION.THERE IS NO GUARANTEE ON THE LIFE OF THE SYSTEM, NOTE: REPORT TWO OF TWO (TWO SYSTEMS) revised 9/2/98 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIVICATION(continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 INSPECTION SUMMARY: Check A,B, C, orD: A] SYSTEM PASSES: X I have not found any information which indicates that the system violates any of the failure criteria as defined in 310 CMR 15.303. Any failure criteria not evaluated are indicated below. COMMENTS: B SYSTEM CONDITIONALLY PASSES: N/A One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The System,upon completion of the replacement or repair,as approved by the Board of Health will pass. Indicate yes,no,or not determined(Y,N,or ND). Describe basis of determination in all instances. If"not determined",explain why not) The septic tank is metal,unless the owner or operator has provided the system inspector with a copy of a Certificate Of Compliance(attached)indicating that the tank was installed within twenty(20) years prior to the date of the inspection;or the septic tank,whether or not metal,is cracked,structurally unsound,shows substantial infiltration or exfiltration,or tank is failure is imminent. The system will pass inspection if the existing septic tank is replaced with a conforming septic tank as approved by the Board of Health. Sewage backup or breakout or high static water level observed in the distribution box is due to broken or obstructed pipe(s)or due to a broken,settled or uneven distribution box. The system will pa pass inspection if(with approval of the Board of Health). broken pipe(s)are replaced obstruction is removed . distribution box is leveled or replaced The system required pumping more than four times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed revised 9/2/98 2 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 35 BRANDY WINE COURT,COTUIT Owner: BUSH, STERLING Date of Inspection: APRIL 21,2000 C] FURTHER EVALUATION IS REQUIRED BY THE BOARD OF HEALTH: N/A Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect the public health,safety and the environment. 1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES IN ACCORDANCE WITH 310 CMR 15.303 (1)(b)THT THE SYSTEM IS NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh. 2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH(AND PUBLIC WATER SUPPLIER,IF ANY) DETERMINES THAT THE SYSTEM IS FUNCTIONING IN A MANNER THAT PROTECTS THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT: The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and soil absorption system and the SAS is within a Zone 1 of a public water supply well. The system has a septic tank and soil absorption system and the SAS is within 50 feet of a private water supply well. The system has a septic tank and soil absorption system and the SAS is less than 100 feet but 50 feet or more from a private water supply well,unless a well water analysis for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen and is equal to or less than 5 ppm. Method used to determine distance (approximation not valid). 3) OTHER revised 9/2/98 3 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH, STERLING Date of Inspection: APRIL 21,2000 D]SYSTEM FAILS: N/A You must indicate either"Yes"or"No" to each of the following: I have determined that one or more of the following failure conditions exist as described in 310 CMR 16.303. The basis for this determination is identified below. The Board of Health should be contacted to Determine what will be necessary to correct the failure. Yes No Backup of sewage into facility or system component due to an overloaded or clogged SAS or cesspool. Discharge or ponding of effluent to the surface of the ground or surface waters due to an over- loaded or clogged SAS or cesspool. Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool. Liquid depth in cesspool is less than 6"below invert or available volume is less than'/:day flow Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s) Number of times pumped Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater elevation. Any portion of a cesspool or privy is within 100 feet of surface water supply or tributary to a surface water supply. Any portion of a cesspool or privy is within a Zone I of a public well. Any portion of a cesspool or privy is within 50 feet of a private water supply well. Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. If the well has been analyzed to be acceptable,attach copy of well water analysis for coliform bacteria,volatile organic compounds,ammonia nitrogen and nitrate nitrogen. E) LARGE SYSTEM FAILS: N/A You must indicate either"Yes"or"No"as to each of the following: The following criteria apply to large systems in addition to the criteria above: The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a significant threat to public health and safety and the environment because one or more of the following conditions exist: Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or mapped Zone II of a public water supply well) The owner or operator of any such system shall upgrade the system in accordance with 310 CMR 15.304(2). Please consult the local regional office of the Department for further information. revised 9/2/98 4 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 35 BRANDY WINE COURT,COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 Check if the following have been done:You must indicate either"Yes"or"No"as to each of the following: Yes No X Pumping information was provided by the owner,occupant,or Board of Health. X None of the system components have been pumped for at least two weeks and the system has been receiving normal flow rates during that period. Large volumes of water have not been introduced into the system recently or as part of this inspection. X As built plans have been obtained and examined. Note if they are not available with N/A. X The facility or dwelling was inspected for signs of sewage back-up. X The system does not receive non-sanitary or industrial waste flow. X The site was inspected for signs of breakout. X All system components,including the Soil Absorption System,have been located on the site. X The septic tank manholes were uncovered,opened,and the interior of the septic tank was inspected for condition of baffles or tees,material of construction,dimensions,depth of liquid depth of sludge,depth of scum. The size and location of the Soil Absorption System on the site Has been determined based on: X Existing information.Ex. Plan at B.O.H. X Determined in the field(if any of the failure criteria related to Part C is at issue,approximation of distance is unacceptable)(15.302(3)(b)] X The facility owner(and occupants,if different from owner)were provided with information on the proper maintenance of Sub-Surface Disposal System. revised 9/2/98 5 / f SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 FLOW CONDITIONS RESIDENTIAL: Design flow: 440 g.p.d./bedroom for S.A.S. Number of bedrooms(design) 4 Number of bedrooms(actual): 4 Total DESIGN flow Number of current residents: 3 Garbage grinder(yes or no): YES Laundry(separate system) (yes or no): NO If yes,separate inspection required Laundry system inspected(yes or no): YES Seasonal use(yes or no) NO Water meter readings,if available(last two(2)year usage(gpd): 1999 71,000/1998 89,000 Sump Pump(yes or no): NO Last date of occupancy: N/A COM M ERCIAL/INDUSTRIAL: Type of establishment: Design flow: Gpd(Based on 16.203) Basis of design flow Grease trap present:(yes or no): Industrial Waste Holding Tank present:(yes or no) Non-sanitary waste discharged to the Title 5 system:(yes or no) Water meter readings,if available: Last date of occupancy: OTHER:(Describe) Last date of occupancy: GENERAL INFORMATION PUMPING RECORDS and source of information: N/A System pumped as part of inspection:(yes or no) NO If yes,volume pumped: gallons Reason for pumping TYPE OF SYSTEM X Septic tank/distribution box/soil absorption system Single cesspool Overflow cesspool Privy Shared system(yes or no)(if yes,attach previous inspection records,if any) I/A Technology etc.Attach copy of up to date operation and maintenance contract. Tight Tank Copy of DEP Approval Other APPROXIMATE AGE of all components, date installed (if known)and source of information: 1980 Sewage odors detected when arriving at the site:(yes or no) NO revised 9/2/98 6 i SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 35 BRANDY WINE COURT,COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 BUILDING SEWER: N/A (Locate on site plan) Depth below grade: Material of construction _ cast iron _ 40 PVC other(explain) Distance from private water supply well or suction line Diameter Comments:(condition of joints,venting,evidence of leakage,etc.) SEPTIC TANK: X (Locate on site plan) Depth below grade: 20" Material of construction X concrete _ metal _ Fiberglass _ Polyethylene _ other(explain) If tank is metal,list age Is age confirmed by Certificate of Compliance (Yes/No) Dimensions: 1,000 GALLON PRE CAST Sludge depth: 2" Distance from top of sludge to bottom of outlet tee or baffle: 28" Scum thickness: 1" Distance from top of scum to top of outlet tee or baffler 12" Distance from bottom of scum to bottom of outlet tee or baffle: 17" How dimensions were determined ASBUILT AND TAPE Comments: (recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,etc.) MAIN TANK AT WORKING LEVEL.OUTLET BAFFLE,TANK AND COVER 20"BELOW GRADE. GREASE TRAP: N/A (locate on site plan) Depth below grade: Material of construction _ concrete _ metal _ Fiberglass _ Polyethylene _ other(explain) Dimensions: Scum thickness: Distance from top of scum to top of outlet tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle: Date of last pumping: Comments: (recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,etc.) revised 9/2/98 7 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH,STERLING Date of Inspection: APRIL 21,2000 TIGHT OR HOLDING TANK: N/A (Tank must be pumped prior to,or at time,of inspection) (Locate on site plan) Depth below grade: Material of construction _ concrete _ metal _ Fiberglass _ Polyethylene _ other(explain) Dimensions: Capacity: Gallons Design flow: gallons/day Alarm present Alarm level: Alarm in working order Yes; No Date of previous pumping: Comments: (condition of inlet tee,condition of alarm and float switches,etc.) DISTRIBUTION BOX: X (locate on site plan) Depth of liquid level above outlet invert: 0 Comments: (note if level and distribution is equal,evidence of solids carryover,evidence of leakage into or out of box,etc,) D-BOX IS 16"X21",29"BELOW GRADE,ONELINE IN.ONE LINE OUT.BOX IS CLEAN AND LEVEL. PUMP CHAMBER: N/A (locate on site plan) Pumps in working order:(Yes or No) Alarms in working order(Yes or No) Comments: (note condition of pump chamber,condition of pumps and appurtenances,etc.) revised 9/2/98 8 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH, STERLING Date of Inspection: APRIL 21, 2000 SOIL ABSORPTION SYSTEM (SAS): X (locate on site plan,if possible;excavation not required,but may be approximated by non-intrusive methods) If not located, explain: Type: Leaching pits,number: 1 Leaching chambers,number: Leaching galleries,number: Leaching trenches,number,length: Leaching fields,number,dimensions: Overflow cesspool,number, Alternative system: Name of Technology: Comments: (note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.) ONE(1)1,000 GALLON PRE CST PIT,PIT AND COVER 20"BELOW GRADE 8"WATER IN PIT NO HIGH STAIN LINE WALLS CLEAN. CESSPOOLS: N/A (locate on site plan) Number and configuration: Depth-top of liquid to inlet invert: Depth of solids layer: Depth of scum layer: Dimensions of cesspool: Materials of construction: Indication of groundwater: inflow(cesspool must be pumped as part of inspection) Comments:: (note condition of soil,signs of hydraulic failure,,level of ponding,condition of vegetation,etc.) PRIVY: N/A (locate on site plan) Materials of construction: Dimensions: Depth of solids: Comments: (note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.) revised 9/2/98 . 9 f SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH, STERLING Date of Inspection: APRIL 21, 2000 SKETCH OF SEWAGE DISPOSAL SYSTEM: include ties to at least two permanent references landmarks or benchmarks locate all wells within 100'(locate where public water supply comes into house) 0 5 � jf,4+ L revised 9/2/98 10 i SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM.I NFORMATION(continued) Property Address: 35 BRANDY WINE COURT, COTUIT Owner: BUSH, STERLING Date of Inspection: APRIL 21, 2000 NRCS Report name Soil Type Typical depth to groundwater USGS Date website visited Observation Wells checked Ground water depth: Shallow Moderate Deep SITE EXAM Slope Surface water Check Cellar Shallow wells Estimated Depth to no groundwater 12 Feet Please indicate all the methods used to determine High Groundwater Elevation: Obtained from Design Plans on record X Observation of Site(Abutting property,observation hole,basement sump etc.) Determine it from local conditions Check with local Board of health Check FEMA Maps Check pumping records Check local excavators,installers Use USGS Data Describe in your own words how you established the High Groundwater Elevation.(Must be completed) TEST HOLE NOTED ON PAGE 10, TEST HOLE 12' BELOW GRADE. 4' BELOW BOTTOM OF PIT. revised 9/2/98 11 SOIL LOG NO. 1 0 N0. 2 SITE PLAN ✓i3tPE4 a�z 2 3 4 -- TOP OF FOUNDATION EL.: _~1s•� rL. 7-- 5 6 b C 7 b ° b , ec; IN E!. ego • b • • 10 o {% IN.EI. >� .,. {N.Et. 2 COVER 1 8 3/8 WASHED STONE _ • �' 12 I N.E L. �• i O !7 O „ ° ' Q U o °° -• ��CJtJN/ 44:.�r_-[:i L • D/B W/ 6`� SUMP IN. a�m� a° T ° ° ° ° 3/4 '-- 1 1/2 WASHED STONE 13 (-- 4' LIQUID LEVEL ° d ° ° b b ° ° C, ° ° 14 6 b © —--! po p . b0 � o oe o o � o ° U : 6"E f F. DEPTH ,,` ° ° e -----� 15 b ae - . , 6 a b 6 b ° PERC TEST RESULTS PRECAST SEPTIC TANK WITH b opa�ob ' . 0°o " PERC RATE: - Vo% od D Doi° PRECAST LEACHING PITS __.�.__,� > -�Ar•• CAST IN PLACE INLET AND EL, °o ' _ ° NO.: ____..� _ SIZE : _ '�%� » - �� WHITNESSED BY: OUTLET T 'S PER TITLE , ' mod_ h ' = BOARD OF HEALTH ti G...,� •�_ d i SIZE : ,ic�ov �AEG �,�✓ i'- ___ D I A . .� `� DATE: PROFILE OF PROPOSED SEWAGE SYSTEM A SYSTEM DESIGNED BY THE TOWN Of REGULATIONS AND STATE TITLE V FOR SUBSURFACE DISPOSAL OF SEWAGE . SCALE • 1/44=_ V 0 " N . B . -- 1. ALL PIPES SHALL BE SCHEDULE 40 P.V.C. SEWER PIPE 2. ALL PIPES SHALL BE SLOPED 1/4 ' PER FOOT EXCEPT FOR ,,► THE FIRST 2 FEET OUT OF THE O s B WHICH ALL BE LEVEL - 3. DESIGN FLOW -- BEDROOMS AT 1,10 GALDAY PER BR . _---.-_� _� GAL/DAY ` � ;� . ✓ v`�����.,r �/� // � SEPTIC TANK SIZE - = � X _-____-- GAL . , , ' f ' '� 'v USE 'vc�=� L. W/ �% GARBAGE DISPOSALf. { '.- LEACHING SYSTEM: USE �f f / f EFFECTIVE AREA : SIDE BOTTOM TOTAL FLOWTOTAL REQ 'D FLOW -2 X W/ Li_,7- GARBAGE DISPOSAL RESERVE FLOW ;�` <a.- `GAL/DAY ` ' `� �- f/�,�► f' /�'' ,,',, ', -- 00000 REFERENCE PLANS : ��, ,ti �� . � -� ; , -�—� �, ��r�; �� y, — - -- APPROVED BY - --- -- a - `� � - s '_.—_._ BOARD OF HEALTH PROPERTY OWNER : -- ------r=T DATE : _ ___ . ______ ____.___-__._ ______.__.�_ SITE . AND SEWAGE PLAN FOR BEDROOM SINGLE FAMILY DWELLING __ ---- LOT : t S a 1 ro 1^ DATE . oc:7 y DOYLE ASSOCIATES FALMOUTH MASS. k