Loading...
HomeMy WebLinkAbout0030 OXFORD DRIVE - Health 3 0 Oxford Drive 1 Cotuit A= 021 - 062 c TC2Wia OF B ARNSTABLE LQC14'FiOAI 3Q U x d-o rz �r, SEWAGE# 3NST .LER'S rd &I' it)idE I SAC'TANK CAPACITY ��� ��`f LE�►C1:IINGMACIL'� ( � s- i� (sue) ::'NO.- BET3t7C3MS UILOER{?R fl TIER PERA rfDATE:. DATE: Separation 135tance Betvieen t2ie: Maximum Adjusted GmundwaterTal3le to tfie Bottompf.L ,hing: 6fity Feet Pnvate Waier Supply: tell a td Lea_cbm' Fi ai AY (if any tV&eXls'c: �a seta�r:wnthgn 2DD feet d leaehissg face) eei Edge of Wetland and Leactung k�aelty(If any wetlands si w[lua 3ti feet of hung f�eility feet /. Furnished by �c y rz �O O b T u' CO) Commonwealth of Massachusetts Title 5 Official Inspection Form ` Subsurface Sewage Disposal System Form:-.Not for Voluntary Assessments t ,M 30 Oxford Dr t , Property Address } , Richard Guagnini �, t Owner Owner's Name information is Cotuit MA 02635 3-14-14 ' required for every * '�'� ' page. City/Town - State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. A. General Information 1. Inspector: Shawn Mcelroy" Name of Inspector Upper Cape Septic Services F t Company Name P.O..Box 73 Company Address E. Falmouth MA 02536 City/Town State Zip Code 1-508-495-0905 S13971 Telephone Number License Number B. Certification r I certify that I have personally inspected the sewage disposal system�at this address and that the information reported below is true, accurate and complete-as of the time of the inspection.The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of E Title 5 (310 CMR 15.000).The system: ,® Passes-r + ❑ Conditionally Passes ❑ fails ❑ Needs Further Evaluation by-the Local Approving Authority, -` ~ate., 3-14-14 Inspector's Signature' "' Date - The system inspector shall submit a copy"of this inspection report to the Approving Authority (Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. ****This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. t5ins•3I13 w - Title 5 Official Inspection Fo . Vurfce Sewage Disposal System•Page 1 of 17 Commonwealth of Massachusetts . Title 5 Official Inspection Form o Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. Cityrrown State Zip Code Date of Inspection B. Certification (cont.) Inspection Summary: Check A,B,C,D or E/always complete all of Section D A) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist.Any failure criteria not evaluated are indicated below. Comments: System is in good working order with no sign of failure. Stain lines in leach pit indicate that system was operating at about 80-85% capacity at one point. B) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health,will pass. ; Check the box for"yes", "no"or"not determined" (Y, N, ND)for the following statements. If"not determined,"please explain. The septic tank is metal and over 20 years old*or the septic tank (whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank'as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND (Explain below): t5ins•W 3 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 17 C Commonwealth of Massachusetts Title 5 Official-Inspection Form, Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M 30 Oxford Dr �d Property Address Richard Guagnini Owner Owner's Name information is Cotuit .1 L MA 02635 3-14-14 required for every page. Cityrrown ,+ Y , State Zip Code Date of Inspection B. Certification (cont.) ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. B) System Conditionally Passes (cont.): >< .r ❑ Observation of sewage backup or breakout or high static water level in the distribution box due to broken or obstructed pipes)-or due to a broken, settled or uneven distribution box. System will ass inspection if with approval of Board of Health #' ❑` ' broken pipes) ar'e replaced ` i❑ Y ❑ N ❑ 'ND,(Explain below): ❑' ' obstruction is•removed ''` '"' ❑ Y ❑tN't'❑' ND (Explain below): ❑ distribution box is leveled or replaced' " ❑ Y ❑ N ❑ ND•'(Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): - ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y• ❑ N ❑ ND (Explain below): C) Further Evaluation-is Required by-the Board of Health: t. •, ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment'." ' 1 System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning'in a manner which will protect public health, safety and the environment: ' ❑ Cesspool or privyris within 50 feet of'a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 3 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form s Subsurface Sewage Disposal System Form-Not for Voluntary Assessments M , ` 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. City/Town State Zip Code Date of Inspection B. Certification (cont.) 2. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance: ** This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis must be attached to this form. 3. Other: D) System Failure Criteria Applicable to All Systems: You must indicate"Yes"or"No"to each of the following for all inspections: Yes No , El ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool El ® Liquid depth in cesspool is less than.6" below invert or available volume is less than Y2 day flow t5ins•W 3 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments- M 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit ,• MA 02635 3-14-14 t. page. Cityrrown State Zip Code Date of Inspection B. Certification (cont.) S Yes- .,No. ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑: ® Any portion of the SAS, cesspool or privy is below high ground water elevation. Any portion of cesspool or privy is within 100 feet of a surface water supply or 'tributary to a surface water supply. ` -. ❑. ® -Any.portion of a cesspool or privy is within a Zone 1 of a public well. ` ® Any portion of a cesspool or privy is Within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy'is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This - system passes if the well-water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis . , and chain of custody must be attached to this form.] The system is a cesspool serving a facility with a design flow of 2000gpd- ' The system fails. I have determined that one or more of the above failure El ,® criteria exist as described in 310 CMR 15.303,therefore the system fails.The -system owner should contact the Board of Health to determine what will be -!• • - necessary to correct the failure. y E) Large Systems: To be considered a large system.the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes"or`;no",to each of the following, in addition to the questions in Section D. Yes No ❑ ❑ the system is within 400 feet of a surface drinking,vvater supply ❑ ❑ the system is within 200 feet of a tributary to,a surface drinking water supply _the system is located in a nitrogen sensitive area (Interim Wellhead Protection ME] °'` �'' ` ' Area— IWPA) or a mapped Zone II of a public water supply well If you have answered"yes"to any question in Section'E the system is considered a significant threat, or answered "yes" in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. t5ins-3h 3 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 5 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form o Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Oxford Dr Property Address Richard Guagnini J ' Own Br Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. City/Town State Zip Code Date of Inspection C. Checklist Check if the following have been done. You must indicate"yes" or"no"as to each of the following: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ® ❑ Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ❑ ® Were as built plans of the system obtained and examined? (If they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ® ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ❑ ® Existing information. For example, a plan at the Board of Health. ® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] D. System Information Residential Flow Conditions: . Number of bedrooms (design): 4 Number of bedrooms (actual): 4 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 440 t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 6 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form ' Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit ti. MA 02635 3-14-14 • page. Cityrrown., State Zip Code Date of Inspection D. System Information Description: Number of current residents: 2 Does residence have a garbage grinder?;4 ❑ Yes ® No Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No information in this report.) ` Laundry system inspected?' '' ",,;f -, - El Yes ® No Seasonal use? ❑ Yes ® No Water meter readings, if available (last 2 years usage (gpd)):, Detail: Sump pump?, El Yes ® No Last date of occupancy: I _.i 3-2014 Date Commercial/Industrial Flow Conditions: Type of Establishment: -Design flow(based on 310 CMR 15.203): Gallons per day(gpd) xt Basis,of design,flow(seats/persons/sq.ft; etc.): •,. fw`•; ,try•.. t„ y t�� ,i'a , � �a ..t• ,. a "; �'` Grease trap present? . j�}� a,,. _ • �- ^;,. . - ❑ Yes ❑ No Industrial waste holding tank present? - ,, a t ., ,.: ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: t5ins•3/13 - Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments .' 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Last date of occupancy/use: Date Other(describe below): General Information. Pumping Records: Source of information: Owner--pumped 8-2013 Was system pumped as part of the inspection? ❑ Yes ® No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: Maintenance Type of System: ® Septic tank,distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology.Attach a copy of the current operation and maintenance contract (to be obtained from system owner) and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank.Attach a copy of the DEP approval. ❑ Other(describe): t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 17 Commonwealth of Massachusetts ;- Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Oxford Dr ' M , Property Address Richard Guagnini , Owner Owner's Name information is required for every Cotuit . MA 02635 3-14-14', page. Cityrrown - State Zip Code Date of Inspection D. System Information (cont.) as - Approximate age of all components, date installed (if known) and source of information: 1986 Were sewage odors detected when arriving at the site? ❑ Yes ® No Building Sewer(locate on site plan):, Depth.below grade: ;1%, 26 feet Material of construction: .r - ..f• . ❑ cast iron J.® 40 PVC` ' ' '❑ other'(explain) ' 'Distance from privatewater supply w`ell or suction line: +, { Comments (on condition of joints, venting, evidence of leakage, etc.): Good condition. a Septic Tank(locate on site plan): _ Depth below grade: #'T "y' 20"feet Material of construction: ® concrete ❑ metal ❑ fiberglass ,,� ❑ polyethylene ❑ other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a.copy-of certificate) ❑ Yes ❑ No Dimensions: , 1000 gal Sludge depth: 8" t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 9 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form, Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Septic Tank(cont.) Ill.' 1 . Distance from top of sludge to bottom of outlet tee or baffle 24" Scum thickness 1" Distance from top of scum to top of outlet tee or baffle 6" Distance from bottom of scum to bottom of outlet tee or baffle 15" How were dimensions determined? Tape Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tank is in good condition with bafles installed and no sign of leakage. There is a tree nearby and tank has minor tree root intrusion. Recommend periodic pumpings to keep under control. Grease Trap (locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 10 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form m Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 " page. Cityrrown ,• State Zip Code Date of Inspection D. System Information (cont.) Y: 4 Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc): J. Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: , Capacity: , gallons Design Flow: "I • c . . 1�� 7 fi gallons per day Alarm present- ❑ Yes ❑ No Alarm level: - Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments (condition of alarm and float switches, etc.): *Attach copy of current pumping contract (required). Is copy attached? ❑ Yes ❑ No t5ins•3/13 Title 5 Official Insp ection Form:Subsurface Sewage Disposal System•Page 11 of 17 Commonwealth of Massachusetts . Title 5 Official Inspection Form A Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Distribution Box(if present must be opened) (locate on site plan): Depth of liquid level above outlet invert 0 Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): Good condition with water at working level and no sign of back-up from pit. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No* Alarms in working order: ❑ Yes ❑ No* Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): * If pumps or alarms are not in working order, system is a conditional pass. Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: t5ins-3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 12 of 17 Commonwealth of Massachusetts _ Title 5 Official, Ins pection"Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ,M 30 Oxford Dr ,. - Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. Cityfrown ..: State Zip Code Date of Inspection D. System Information (cont.) _ . . Type: _, , ... ,i're • � � t h ,y, i � . ® leaching pits number: 1-1000 gal ❑ leaching chambers number: ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields ,-,-number,.dimensions:, ' ❑ overflow cesspool + number: ❑ innovative/alternative system Type/name of technology: Comments (note condition of soil,,signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): Leach pit in good condition and holding water at 36" below inlet invert. Stain lines at 16" below inlet invert indicate the leach pit had been operating at about 80-85% capacity at one point. Cesspools(cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool , Materials of construction Indication of groundwater inflow ❑ Yes ❑ No t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 13 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments w 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): Privy (locate on site plan): Materials of construction: Dimensions Depth of solids Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): i t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form �. Subsurface Sewage Disposal System Form -Not for Voluntary Assessments , a 30 Oxford Dr • r^ Property Address , Richard Guagnini r Owner Owner's Name information is required for every Cotuit ' ' ,." MA 02635 3-14-14 page. City/Town - State Zip Code Date of Inspection D. System Information (cont.) Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ® hand-sketch in the area below ❑ drawing attached separately - 1 H e '< 40 R t t t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal p g System•Page 15 of 17 Commonwealth of Massachusetts . Title 5 4fficia[ Inspection Form Subsurface Sewage Disposal System Form -Not for.Voluntary Assessments 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 1 Site Exam: ❑ Check Slope ❑ Surface water ❑ Check cellar ❑ Shallow wells Estimated depth to high ground water: 20 feet Please indicate all methods used to determine the high ground water elevation: ❑ Obtained from system design plans on record If checked, date of design plan reviewed- Date ® Observed site (abutting property/observation hole within 150 feet of SAS) ® Checked with local Board of Health -explain: ® Checked with local excavators, installers- (attach documentation) ® Accessed USGS database- explain: You must describe how you established the high ground water elevation: USGS and town maps show groundwater at greater than 20'. Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5ins-W 3 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 16 of 17 Commonwealth of Massachusetts Title 5 official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 30 Oxford Dr Property Address Richard Guagnini Owner Owner's Name information is required for every Cotuit MA 02635 3-14-14 page. Cityrrown State Zip Code Date of Inspection E. Report Completeness Checklist ® Inspection Summary:A, B, C, D, or E checked ® Inspection Summary D (System Failure Criteria Applicable to All Systems) completed ® System information—Estimated depth to high groundwater ® Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file t5ins-3M3 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 17 of 17 ASSESSOR'CN AP NO PARCEL (®� L0-CAT od ' 7 `� 'r` SEWAVE PERMIT NO. 073 LOT VILLAGE INSTALLER'S NAME i A D D R I S SDo fit,vi BUILDER OR OWNER a a Q �, cif ru c a DATE PERMIT ISSUED i - DATE COMPLIANCE ISSUED • /6 . , � � � r �' r ��r �r a.�����ppr, V� . lr' �.. t .. No.......Ka.::e_6_7 FIEs.....:�(.......... _ THE COMMONWEALTH OF MASSACHUSETTS BOAR® OF HEALTH S SUBJECT TO APPROVAL OF ---------T wN-.. OF...... i9i2//,STe9- G�`�------1?-" ' ;i -��1�LE CONSERVATION 0�`' o .�llplua tiun for Dispao al Works Tongtrnrtiun e R MA Application is hereby made for a Permit to Construct (tor Repair ( ) an Individual Sewage Disposal System at: D/Z1 ve___r, a ��- �� . 79 Location Address or Lot No. 771G1G� :2. __-6°gc�G N/^// �a�.Q !�z�A?7. 9D W�T13o/Zo q Owner / Address .................................................✓._ ..- ----�'? �""'"�.7�C.- Installer Address d Type of Building Size Lot..,2-4,..7e>P.......Sq. feet f- Dwelling—No. of Bedrooms.............:......_._........._•.........Expansion Attic ( ) Garbage Grinder Other—Type T e of Building No. of persons............................ Showers C4 YP g ---•----•----•-•---•----•--• P ( ) — Cafeteria ( ) A, Other fixtures ..---•••......-•--•-•---•-•---•- - W Design Flow.................�T..........--._......__gallons per person per day. Total daily flow___-•---•_-:-- 5'9.....................gallons. WSeptic Tank—Liquid capacity-!�?�o.gallons Length..$. Width.-,/-. Diameter................ Depth__4718,'- x Disposal Trench—No. .................... Width.................... Total Length................. Total leaching area....................sq. ft. f' Seepage Pit No..................... Diameter-----/a Depth below inlet.....G....._..... Total leaching area._Z�7------sq. ft. !, Z Other Distribution box ( ) Dosing tank ( ) Percolation Test Results Performed by__/Y-P '=spas Sul2.v�/ Date... .:. a Test Pit No. 1..G-.Z.__-_minutes per inch Depth of Test Pit___1���.__..//Depth to ground water......-"'_____________ G%, Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ P4 •••--•••-------------•------••-•._......._.....•-••-•-•--------.....•-----------...............-----......................................................... 0 Description of Soil......2!1-04 7v f, 1-f4- 4"07ZSGf' Sy-�v ---- --•-•-----------•---------------•-••-------•--••---• -••••••-•--------......_._..-•-•- x c, W ---•--•-•-•----------•-•----•----•-----------------••-•--•-•---•••......-----•---•-••--------••--•----•------••-•-•------------------••-•---------•-•--•--•-----•----•-----•-•---••••-•-------•----•--- U Nature of Repairs or Alterations—Answer when applicable...................................................•__.___.__._..._.........................__. -- --------------------•--•--•---•-••••---------•----•-- Agreement: ' The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Sanitary Code—The undersigned further agrees not to place the system in operation until a Certificate of Compliance has been issued by the board of health. . , eSigned.....•.. .... ....... °f .Application Approved By............... ... ...b...... �__�_/�ate Application Disapproved for the fo reasons:--- -•--••----••---•----•--•----••------•-••-----•---•-•---•••-------•----•--•••-----------•----•............._ .............................................. -•--•---------......-•-------------........---...•.........__....--•--•---------------------------•--•----------------------------------------••-•--.-•--- Date PermitNo......................................................... Issued_..........................................:............ Date No........................ Film...... ................. THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH .............7.Z.1..............OF........ .. ........... ............................. Appliratt-, U f 6x Buipasal Wilds Tomitrurtion' "prrmit Application is hereby made for'a"Permit to Construct or Repair, an %Individual Sewage Disposal System at: 0X)1:7P_2 D -P/Z I Ve--- C�e>7& /7— 14-14 79 ............ ;r Location es; or Lot No ....................... ............................. .....?9P........ Owner .100" ddress .............y..................................... t ..... .................... .....RM .........CA!..... . ui;(n _W__�___ - --------------------- ------- ---------- Installer Address Type of Building t.2-4.70 U Size Lo ......I ......!;?�.......Sq. feet Dwelling—No. of Bedrooms.................__._.._.._......._.._..__..Expansion Attic Garbage Grinder Other—Type of Building ............................ No. of persons.........._.._.._.__........ Showers Cafeteria Other fixtures Design Flow.................5:6 ............................gallo ns per person per day. Total daily flow..............3._�47_49......................gallons. W Septic Tank—Liquid' 4. ' 4.`4 '_ Diameter--------------_ Depth.A74f­ capacity_��,?R.gallons Length. '..-. Width- Disposal Trench No..................... Width........_....__..... Total Length....._.............. Total leaching area....................sq. ft. Seepage Pit No.. ../............ Diameter-----Vi0........_ Depth below inlet.....6............ Total leaching area.JZ47......sq. ft. Z Other Distribution box Dosing tank Percolation Test Results Performed by_i;�_ VA-5,619%-P-5 4--V.......... Date.2�_-_?._ /,f49Z_ 4 / ----------------------------- r 1, ." :11,------------------- Test Pit No. -----minutes per inch Depth of Test-Pit...�1�....... Depth to ground water------............... PLI Test Pit No. 2................minutes per 4inch Depth of Test Pit___.............._.. Depth to ground water....._--.._............. Ra' .......................71.................................................................................................................................... 0 Description of Soil...._O-4�'Z�.... .. ......................................................................................................................... .................................................................I........................................................................................................................................ ..............................................................................................................................................................0.............. .......................... U Nature of Repairs or Alterations—Answer when applicable......................I-----------------------------------------------------------1*111*­_1­ ....................................................................................................................................................................................................... Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Sanitary Code—The undersigned further agrees not to place the system in operation until a Certificate of Compliance has bee issued by the board of health. Signed--....... ... ... ...... ...... .77 441............ i 7 It-49pc r ApplicationApproved" By................... ... ........ .......4................................. ................r......t­............ Date g reasons:...Application Disapprovedfor the follo ...................................................................................................... ....................................................................................................................... ................................................................................. Date ."Permit No......................................................... IssuedL....................................................... Date THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH .......... ...........OF..... ............................... %ardifiratr of (Imphatta THIS IS TO CERTIFY That the Individual Sewage Disposal System constructed or Repaired by-------------------------------------------- ------------ ...I................................................................................................................................... at.......GOT.46-toM..............o ........W*----Installer ..........................o.................................................................... .................... ..................... ............... ......... has been installed in accordance with the provisions of TITLE 5 of The State Sanitary Cod as escribed in the -7_ applicatiofi for Disposal Works Construction Permit NoAZ_5"6_1)._*31...0........... dated .................... THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GU A4TEE THAT THE SY,STEM WILL F (TION SATISFACTORY.N DATE.................. ...................................... Inspector.......... ..... .............................................................. THE COMMONWEALTH OF MASSACHUSETTS' BOARD OF HEALTH ........... .............0 F.......... ......................................................... N o....?-S-L-7-7-3. FEE... .. QC ....... Mapoal Works Tyantstrudiatt ramit Permission is hereby granted.............. - ----- ....pyv—r�ivs........................................................... to Construct orlRepair ,( an Individual Sewage Disposal System at No. L..J�r ji.tiq 40kl�?"....................................................................................................... ......I------------------- Street as show;i on the application for Disposal Works Construction Permit NoS576I.J. Dated.__........._[------ ------------ -----S14.i� ............. ................. ... .................... DATE.............. 956........................ 'FORM 1255 A. M. SULKIN. INC.. BOSTON .� AI PO Al b f oz,l -'`-�.�L,\ Top e% 7y7 ,e -- Z4; Tao S40, + 2c � 2Z, _—— 1 ' — : PRoP os Z ' 310 �I Z i• i t a . n d c o sf 32' � �vrG • /D0 X ►�t.� 1 44 i2, Yu Nov �1 Lew f 34 � � I C of s d'' 36. VL- SI T� P41- �I �A EZal/,1'770N.7 46AW;ea ON 1-9e;- T" SG-;9 IDCATION SCALE . /.. .3a' . . . DATE .1.vF PLAN REFERENCE . ,etwlG . .L67-w .71�'. P/L000s�v cr y 34, z7/. . . . . . . . . . .. . . . . ..---- ,UELLE`( CERTIFY THAT THE No. 25ICO � SHOWN ON THIS PLAN 19 LOCATED ON THE OROVND �`<`i9,,\! AS SHOWN HEREON AND THAT IT CONFORMS TO THE SETBACK REQUIREMENTS OF THE TOWN OF II WREN CONSTRUCTED. II` DATE . . . . . . REOISTERED LAND SURVEYOR T Z of 2 .S11 Z 7--5 r TOP OF FOUNDATION CONCRETE COVER TCONCRETE COVERS 4'� 2 CAST IRON I�7 I ` OR SCHEDULE 40 MAX. 12"MAX. • P.V.C. 4 SCHEDULE 40 P.V.C.(ONLY) PIPE ' PITCH PIPE ER.FT PIPE - MIN. LEACH PITCH 1/4'PER.FT. PIT PRECAST INVERT u LEACHING ° EL.-3!. J. ... \-INVERT INVERT p w �? S:: PIT OR e , SEPTIC TANK DIST. EL.•,T/,Z/. . . ELF°r 13. _>_ EQUIV. e INVERT BOX e; EL.-3/:3 ... /000. .. .. GAL. INVERT G� F-► 0: ;.0. �. / EL3//p. INS 6o ww �: .°. 3/4 TO II/2 !., EL......... :. u• WASHED v ° /to , 5- z STONE E' . Z¢,Lo ... DIA PROF LE OF GROUND WATER TABLE WA�'L G•rZ.b'Y, SEWAGE DISPOSAL SYSTEM NO SCALE SOIL LOG WITNESSED BY : DATE .!'qr?•.z I ?- TIME. . . . . . . . . . . ��Y Ci�Fol�O 2.5, BOARD OF HEALTH TEST HOLE I TEST HOLE 2 Cf►�E�`rsl��DS -Su�eV�! ENGINEER ELEV. .3Z.Lo . . . ELEV. .. .. . . . . . . -- DESIGN DATA : z4 rz. 30,4 o NUMBER OF BEDROOMS 3 TOTAL ESTIMATED FLOW 33o GALLONS/DAY Co BOTTOM LEACH I NG AREA �B:S . SQ.FT. /PITIC.P.Z%_ SA�o. SIDE LEACHING AREA . , �BB:'So . . . SQ.FT./ PIT/4-7/ CAD, GARBAGE DISPOSAL (50% AREA INCREASE) , G? Zo.lo TOTAL LEACHING AREA . ?- 7:Qp. . SQ.FT /44" PERCOLATION RATE [ems. R"! .?�!�. MIN/INCH LEACHING AREA PER PERCOLATION RATE SQ.FT.1C,P,D, /Vo .WATER ENCOUNTERED � NUMBER OF LEACHING PITS .oNE T. . . . . . . . .1Ni�. . APPROVED . . . . . . . . . . . . . BOARD OF HEALTH • IWo• ���;7—• 0F. s7DAle 0,V �ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DATE . . . . . . . . AGENT OR INSPECTOR N OF MA 41.4S y�if ZoT " 79 -_ E. D�'Fo/ZD KELLEY /7 u,I /V�r. . . No. 26100 `4 6'�'7Z,i 7- /`9,9 SS. . . 04 r� AfGISTi �� s%s SwrortAM�� PETITIONER : CLvei '6 ° �11 lC;I u9CN�N/ ��ws�" / ASSESSOR'r ' AP NOl PARCEL (o L 0 C A T I �' it S EWA E PERMIT NQ. VILLAGE _I 1>INSTA LLER'S NAME ADDRISS R U I L D E R OR OWNER Jut DATE PERMIT ISSUED DATE COMPLIANCE ISSUED i 1. i 1