HomeMy WebLinkAbout0265 FOREST STREET - Health 'j J'E7REST
:ST_REET, HYANNIS
P � °
°
a
i °
i
el
12TROY WILLIAMS �SEPTIC INSPECTIONSEI
Certified iy MA Department of Environmental Protection . (501 760-1819
40 Old Bass River Roadj¢�quH
South Dennis,MA 02660
A
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPi- RM
Address of property 26 5 f- St. (Je S-f H
Owner's name& go �-J, !34 c d
Mailing address
Date of Inspection 9,1d If 5
PART A
CHECKLIST
Check if the following have been done:
Pumping information was requested of the owner, occupant and Board of Health.
None of the system components have been pumped for at least two weeks and the
system has been receiving normal flow rates during that period. Large volumes of
water have not been introduced into the system recently or as part of this
inspection.
N/'i As built plans have been obtained and examined. Note if they are not available with
N/A.
The facility or dwelling was inspected for signs of sewage back-up.
The site was inspected for signs of breakout.
I -
All system components, excluding the SAS, have been located on the site.
N1/a The septic tank manholes were uncovered, opened, and the interior of the septic
tank was inspected for condition of baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge, depth of scum.
The size and location of the SAS on the site has been determined based on existing
information or approximated by non-intrusive methods.
The facility owner(and occupants, if different from owner) were provided with
information on the proper maintenance of SSDS.
Page 1 of 7
G
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
SYSTEM INFORMATION
FLOW CONDITIONS
If residential
number of bedrooms
number of current residents
i o garbage grinder, yes or no
No laundry connected to system, yes or no
�5 seasonal use, yes or no
If nonresidential, calculated flow:
Water meter readings, if available: �/�.�, 2Y S
✓���-h L9 U,-s . Last date of occupancy
GENERAL INFORMATION
Pumping records and source of information:
4--
AA) System pumped as part of inspection,yes or no
If yes, volume pumped
Reason for pumping:
Type of system
Septic tank/distribution box/soil absorption system
Single cesspool
Overflow cesspool
Privy
Shared system(yes or no) (If yes, attach previous inspection records, if any)
Other(explain)
Approximate age of all components. Date installed, if known. Source of information:
C� , �.w 1 -fro �n K /» , l f— 7c1 ram.- S �k s=�.�,e.o
Sewage odors detected when arriving at the site, yes or no
Page 2 of 7
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
SYSTEM INFORMATION continued
SEPTIC TANK: (locate on site plan)
depth below grade:
material of construction: concrete metal. FRP other(explain)
dimensions:
sludge depth
distance from top of sludge to bottom of outlet tee or baffle
scum thickness
distance from top of scum to top of outlet tee or baffle
distance from bottom of scum to bottom of outlet tee or baffle
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation
.to outlet invert,structural integrity,evidence of leakage,recommendations for repairs,etc.)
DISTRIBUTION BOX:f�/� (locate on site plan)
depth of liquid level above outlet invert
Comments:
(note if level and distribution is equal,evidence of solids carryover,evidence of leakage into or out of box,
recommendation for repairs,etc)
PUMP CHAMBER: (locate on site plan)
pumps in working order, yes or no
Comments:
(note condition of pump chamber,condition of pumps and appurtenances, recommendations for
maintenance or repairs,etc.)
Page 3 of 7
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
SYSTEM INFORMATION continued
SOIL ABSORPTION SYSTEM(SAS): A///�
(locate on site plan,if poss.;excavation not required,but may be approximated by non-intrusive methods)
If not determined to be present,explain:
Type:
leaching pits and number
leaching chambers and number
leaching galleries and number
leaching trenches, number, length
leaching fields, number, dimensions
overflow cesspool, number
Comments: (note condition of soil,signs of hydraulic failure,level of ponding,condition of
vegetation,recommendations for maintenance or repairs,etc.)
CESSPOOLS (locate on site plan) : V
number and configuration to$I�
depth-top of liquid to inlet invert -5
depth of solids layer Al OHC
depth of scum layer /V 0/yr'
dimensions of cesspool S d�p Y S d
materials of construction C�.s s , 6 Jo
indication of groundwater inflow
(cesspool must be pumped as part of inspection) C c S s 6 / . w dk t cA��—
Comments: (note condition of soil,signs of hydraulic failure,level of ponding,condition of
vegetation,
recommendations for maintenance or repairs,etc.)
7u� I 7�+�..� � t7 r0 � !J�✓t c�N a ; •• �.c � /- r� �S a N L SF-�.—
/'
or
(locate on site plan)
materials of construction
dimensions
depth of solids
Comments: (note condition of soil, signs of hydraulic failure, level of ponding,condition of
vegetation, recommendations for maintenance or repairs,etc.)
Page 4 of 7
i
t
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM''
PART B
SYSTEM INFORMATION continued
SKETCH OF SEWAGE DISPOSAL SYSTEM:
include ties to at least two permanent references landmarks or benchmarks
locate all wells within 100'
I
i
R SIDE .
6 �
3=
y �
s;kyte-
C4 ss�,00
DEPTH TO GROUNDWATER
S� depth to groundwater — adjusted high groundwater level
method of determination or approximation:
Page 5 of 7
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
FAILURE CRITERIA
Indicate_yes, no or not determined(Y,N, or ND). Describe basis of determination.in all
instances. If"not determined", explain why not)
Backup of sewage into facility?
A/ Discharge or ponding of effluent to the surface of the ground or surface waters?
lU/fl Static liquid level in the distribution box above outlet invert?
A/ Liquid depth in cesspool<6"below invert or available volume< 1/2 day flow?
Required pumping 4 times or more in the last year?
Number of times pumped
Al A Septic tank is metal? cracked? structurally unsound? substantial infiltration?
substantial exfiltration?tank failure imminent?
Is any portion of the SAS, cesspool or privy:
below the high groundwater elevation?
within 50 feet of a surface water?
within 100 feet of a surface water supply or tributary to a.surface water supply?
within a Zone I of a public well?
within 50 feet of a bordering vegetated wetland or salt marsh(cesspools and privies
only, not the SAS)?
within 50 feet of a private water supply well?
less than 100 feet but greater than 50 feet from a private water supply well with no
acceptable water quality analysis? If the well has been analyzed to be acceptable,
attach copy of well water analysis for coliform bacteria,volatile organic
compounds, ammonia nitrogen and nitrate nitrogen.
Page 6 of 7
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART D
CERTIFICATION
Name of Inspector: Troy Williams
Company Name: TROY WILLIAMS SEPTIC INSPECTIONS
Company Address: 40 Old Bass River Road, South Dennis,MA 02660
Certification Statement
I certify that I have personally inspected the sewage disposal system at this address and
that the information reported is true, accurate and complete as of the time of inspection.
the inspection was performed and any recommendations regarding upgrade, maintenance
and repair are consistent with my training and experience in the proper function and
maintenance of on-site sewage disposal systems.
Check one:
__V 1 have not found any information which indicates that the system fails to adequately
protect public health or the environment as defined in 310 CMR 15.303. Any failure
criteria not evaluated are as stated in the FAILURE CRITERIA section of this form.
I have determined that the system fails to protect public health and the environment
as defined in 310 CMR 15.303. The basis for this determination is provided in the
FAILURE CRITERIA section of this form.
Inspector's Signature
Date 8 /a /C/ 5
Original to system owner
Copies to :
Buyer(if applicable) /3a✓ n S
Approving authority
PROPERTY ADDRESS:
5
_ VVc i'} /T/� n,n /moo✓ �
Page 7 of 7