Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
33-35 HIRAMAR ROAD - Health
47) s §7 21, orr �.�. '�k�'" o o i - i 0 o � No. 2LFee �©� Y ��•� i_ THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: Ye PUBLIC HEALTH DIVISION - TOWN OF BARNSTABLE, MASSACHUSETTS 2pplication for Misposal *pstrm Construction 3pPrmit Application for a Permit to Construct( ) Repair( ) Upgrade(N Abandon( ) ❑Complete System ❑Individual Components Location Address or Lot No.7��,�r-5b "k TY—N Owner's Name,Address,and Tel.No. Assessor's Map/Parcel 1 "L—M AA I-M�.� CSMe- Ga2922 Installer's Name,Address,and Tel.No.--nL� Designer's Name,Address,and Tel.No. lT lNn:> CC ��C�Cit1 C ,�c\e v uuo< Vsc v.b C'ao \2 �ZC Type of Building C Dwelling 'No of Bedrooms``_` Lot Size sq.ft: ' Garbage'Grinder Other Type of Building �U�y� I C1e� , No.of Persons Showers( ) Cafeteria( ) Other Fixtures ��•±+ Design Flow(min.re uiired) �p gpd Design flow provided GG 51_1 gpd Plan Date ) `(p Z� Number of sheets Revision Date Title d � 0 Size of Septic T ` 60 t\1 )i Type o S. .S. Description of Soil Nature of Repairs or Alterations(Answer when applicable) Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certificate of Compliance has been issued by this Board of Health. Signed 6ZDate Application Approved by V�AYVILWIA.!Nau_ 2 Date Application Disapproved by Date for the following reasons Permit No. �'{"' -�� Date Issuedt } ,.: .' �' ,�„ ��... ,;,; �� - x _. -• it 4 No. Entered Fee in computer:�s THE.COMMONWEALTH OF MASSACHUSETTS - Yes PUBLIC HEALTH DIVISION.- TOWN OF BARNSTABLE, MASSACHUSETTS 9pplitatton for Misposat*pstem Coustrurtion permit Application for a Permit to Construct Repair U Upgrade Abandon ( Complete System Individual Components c PP ( ) ( ) Pg � ( ) ❑ P Y ❑ P Location Address or Lot No. '� r" , - � .^Owner's Name,Address,and Tel.No. Assessor's Map/Parcel � "�t'� D�11"Y�► i• L �1 .. 'JCY�P( �"1 Installer's Name;Address,and Tel.No. L� r�`' Designer's NamelAddress,and Tel:No. "l'[�c �, c M � a� n5 � .� c=fir _ - z Type of Buildings ` DwellingNo.of Bedrooms Lot Size e�, j� s .ft. Garbage Grinder q g ( ) Other Type of Building C\.kx)\r_-," 1 No.of Persons Showers( ) Cafeteria( ) Other Fixtures �^/ �, �•-� Design Flow(min.required) yy gpd Design flow provided gpd Plan Date 1 Number_o�f sheets ., Revision Date 4 �. Title VC1C71 - 4 Size of Septic Tank/(�� } Type ofS�A�S \ '1 (`�(;t, t1 ?t" '�-�(- k \C'i � Description of Soil �i11\ Nature of Repairs or Alterations'(Answer when applicable) Date last;inspected: Agreement: ` The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certificate of Compliance has been issued by this Board of Health. l —1 �-LoSigned Date, � ..-��.'�•�" Application Approved by V�A U J Date 1� 1 tf , e Application Disapproved byG Date for the following reasons Permit No. 0 -�r-77 Date Issued ( / THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE,MASSACHUSETTS Certificate of Compliance THIS IS TO CERTIFY,that the On-site Sewage Disposal system Constructed( ) Repaired( ) Upgraded Q(� Abandoned( )by i c\C1'� 4f#A has been constructed in accordance with the provisions of Title 5 and the for Disposal System Construction Permit No.�,(ja r-;1-7 d7ted -7 /a I Installer Designer �—__cvx,, \'CNr #bedrooms v Approved design�w A _ gpd The issuance of this pe` it shall not be construed as a guarantee that the system will ctio designed Date 1 I 1 Inspector Cs[ t n> No. f,;�0 all y Fee I 4e THE COMMONWEALTH OF MASSACHUSETTS, PUBLIC HEALTH DIVISION-BARNSTABLE, MASSACHUSETTS Misposal *pstem Construction i3ermit` Permission is hereby granted to Construct( ) Repair( ) Upgrade( ` ) Abandon{ ) Sys tem.located at AA A and as described in the above Application for Disposal System Construction Permit. The applicant recognized his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided:Construction must be completed within three years of the date of this permit. ' Date L >A Approved by V%.1 I. Town of Barnstable Regulatory Services •: Richard V:Scab��Interim Director � Bn�xara8u. � - Public Health Division 'Rt� a Thomas McKean,Director 100'Drain Street,Hyannis,AM 02601 Office: 508-862-4644 Fax. 565440'6304 Installer&1}esianer Certification Form Date �� "2-3�Zt Sew a a Permit# Assessor's Map\Parcel: ` Designer: �nC; installer: j�n vt`S c.yvfic. Address: 1 Z ttilc.C Id fz� Address: �T � on 2.1` `�"� `c �•�; �� was issued a permit to install a. (date) (installer) septic system at 144 q based on a design drawn by (address) dinar 1tx 1 � dated '3�.t 1� .Zt 'l�Cx ✓ 7 f o (2 t (designer) I certify, that the septic system referenced above was installed substantially according to the design„which may include minor approved changes such as lateral relocation.of the distribution:box anchor septic"tank. Strip out (if required) was inspected and the soils were.found satisfactory: . 1 certify iliac the septic system referenced above was installed with major changes (i„e; ggreater than I-W lateral relocation of the SAS ar any vertical relocation of Any component of:the septic system)but in accordance with State&LoeaI Regulations. Plan revision or certified as=Built by designer to follow. Strip out(if required)was inspected and the soils were found,satisfactory. I certify tlaafi-the system.referenced above was constructed in... with the terms of the l\A prova letters(if applicable) M" {instal er's Si store) ttittL t0.3510 (1}esigner's Signature (Afftx.IDesign ere)— PLEASE RETURN, TO,BARNSTABLE M BLIC REALTH DIVISION. CERTIFICATE OF.COMPLIANCE WILL NOT BE ISSUED UNTIL BOTH. H,,IS;FoRM .AN.D A.S BUIiLT CARD ARE RECEIVED BV TIME"BARNSTABLE,PUBLIC HEALTH DIVISION. THANK YO1 . ft:lSc4 t��5i7es gner GEC€ icati�a t oxi.►Rev.8-t413_doc Engineers note:This certification is limited to an as4wilt inspection of system components as installed prior to backfill.The engineer did not supervise construction of the system.The installer assumes responsiisitity for alt materiats,workmanship,fiackilEling to spectHed.grade&vrith proper compaction and setting fterstcouers as shown 0 the design plan. 3/4/2 21 14. Gmail-21/23 Hiramar Rd='A Hiramar Rd Hyanis NE Tel 30'Easement t ' grail PETER MCENTEE<peter.mcentee@gmail.com> 21/23 Hiramar Rd and 33/35 Hiramar Rd Hyanis NE Tel 30' Easement 2 messages PETER MCENTEE<peter.mcentee@gmail.com> Wed, Mar 3, 2021 at 3:45 PM To:daryl.crossman@verizon.com Daryl, I am designing on site septic systems for two duplexes in Hyannis.They are 21/23 Hiramar Rd and 33/35 Hiramar Rd. Each property has a 30' NE Tel"Telegraph Easement running through them. Can you tell me if placing all, or any part, of the septic system within the easement is prohibited? i have noticed that there are some adjacent properties that have septic system components within the easement. Please respond as soon as possible as the septic systems are in failure and need to be replaced. Attachments are 1)Land Court Plan showing easement, 2)Draft plan of septic systems Thanks you-Peter Peter T. McEntee PE-Principal Engineering Works, Inc. 12 West Crossfield Road Forestdale, MA 02644 Tel/fax(508)477-5313 2 attachments in Hiramar Rd Hyannis PROPOSED SEPTIC SYSTEMS.pdf 108K LAND COURT 21 &23 Hiramar Rd and 33&35 Hiramar Rd .pdf 919K daryl.crossman@verizon.com<daryl.crossman@verizon.com> Thu, Mar 4, 2021 at 7:16 AM To:"peter.mcentee@gmail.com"<peter.mcentee@gmail.com> Hi Peter This appears to bean old proposed potential Telephone Transmission corridor that was never used,and would not be- used. I see no issue with your request as proposed. Good luck! Daryl Crossman ROW Manager—Verizon hftps://mail.google.com/mail/u/0?ik=Odf625939b&view=pt&search=all&permthid=thread-a°/a3Ar-3431946125795308818&simpl=msg-a%3Ar-34302936... 1/2 f� J ——64—— EXISTING CONTOUR N 6 s x 60.98 EXISTING SPOT GRADE °^ss, LQCus —W EXISTING WATER SVC. ROUTE 28 s —G EXISTING GAS SERVICE /L a oy e- --&H.4V— OVERHEAD WIRES P� o Rd µ}rimor od TEST PIT 3� BENCHMARK " 5r F LEGEND 0 j a � O Eldrid9e potton Ave. LU 7T LOCUS MAP PROPOSED S.A.S. NOT TO SCALE 5-500 GALLON CHAMBERS SURROUNDED W/4' OF STONE edge 1 V%� — — 9 77__ 97.34 C 97.90 of O o s/OFF 9 714 2 �<P BENCHMARK-2 9 CENTER OF STOOP o �; :r:; -•;; ,\(Ir CB o Ift E =102.32 CBSEAL L. '� ?� ,/� ` �o/ 97, 9 TP-1 PK 99.63 / FO' TP-304 �� � �,� r�' ,�. / R FRS ,�• 1 ,® \ o �, i 100,46 RE9 ��:�`:: 97,71 �i � 99 4 � O +Z L�_lj // �� / + 7 ALK 101 0 / + .54 97,85 � � W x 100.61 x 101,32 101.16 p? 101.36 10 ,32 100.4 O.H.W r =0.H.W 35 TING D o (pi & 35)� 33 PROPOSED SEPTIC TANK S T.O.F.=102.9-+ 101.05 W W_7L__ 1000 GALLON H-10 o SLEEVE SEWER 451 .�� S DECK 101,24 x 101.4 101.51 x G G BENCHMARK-1 >00,67 CORNER/STP G 100,93 101. EL.=102.02 G 100,84-,'-:.,',-:-•,.y. EXISTING LEACH PITS (APPROX.—FROM ASBUIL T) TO BE PUMPED, FILLED W/SAND -N:` & ABANDONED OR REMOVED .. 1:i.. 1 V•�`Ll� 100,90 n A. - 101,34. 101.36 101.12 GSO EXIS77NG SEPTIC TANK ioi;31 TOP OF TANK, EL.=99.22t IN V.(OUT)=97.89f(VERIFY) ;101,63 PK SET: 101,25. PLAN REVISION 7/15/21 101.15 1) TYPO CORRECTION TO SOIL LOG, TP-1 & 2 DEPTH 2) TYPO CORRECTION IN DESIGN CRITERIA 3) ADD NOTE 15, SHEET 2 ofss9cy� PARCEL ID: 292-148 o PETER T. M CIVILEE N PROPOSED SEPTIC SYSTEM UPGRADE PLAN No. 35109 33 & 35 HIRAMAR RD, HYANNIS, MA Ss _ Prepared for: Quinn's Excavation, 39 Bog River Bend, Mashpee, MA 02649 OWNER OF RECORD Engineering by: SCALE DRAWN JOB. NO. CASTLE INVESTMENT GROUP INC Engineering Works, Inc. 1"=20- P.T.M. 322-20 ( 49 ORR'S AVENUE 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. HYANNIS,, MA 02601 (508) 477-5313 3/16/21 P.T.M. 1 Of 2 .r NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:96.5 FOR A DISTANCE OF 15' AROUND THE SEPTIC TANK PERIMETER OF THE S.A.S. INSTALL RISERS & COVERS OVER THE PROPOSED D-BOX PROPOSED S.A.S. INLET & OUTLET AS REQUIRED SET TO INSTALL RISER & WATERTIGHT FRAME INSTALL RISER, FRAME & COVER OVER ONE 6" OF FINISH GRADE. AND COVER SET TO FINISH GRADE CHAMBER AND SET TO FINISH GRADE TO SERVE AS INSPECTION PORT. F.G. EL.=101.2t F.G. EL.=100.1t F.G. EL.=100.3t F.G. EL.=100.0t L = 61' L = 30' L = 23' S=1% (MIN.) S=1% (MIN.) ® S=1% (MIN.) 2" LAYER OF 1/8" TO 1 2 4"SCH40 PVC 4"SCH40 PVC 4"SCH40 PVC / 6" DOUBLE WASHED STONE 10"I " 6 a®aSaaB (OR APPROVED FILTER FABRIC) INV.=97.0 t4" INV.=96.40 aaaaaee 48" UQUID �-3/4" TO 1-1/2" DOUBLE ADD ADD PROPOSED 4' 4.8' 4' WASHED STONE cAS BAFFLE INV.=96.23 INV.=97.89 GAS BAFFLE EFFECTIVE WIDTH = 12.8' • . • VERIFY H-20 X S G r INV.=96.75 INV.=96.00 1500 GALLON PROPOSED SEPTIC TANK 5-500 GALLON LEACHING CHAMBERS SEPTIC TANK 1000 GALLON, H-10 SURROUNDED WITH STONE AS SHOWN H-20 RATED NOTES: TOP CONC. ELEV.=97.1 t 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & BREAKOUT ELEV.=96.50 aaaa INV. ELEV.=96.00- ease INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. mamas mamma mmaa amass 2) SEPTIC TANK & D-BOX SHALL BE SET LEVEL AND BOTTOM ELEV.=94.00 TRUE TO GRADE ON A MECHANICALLY COMPACTED 4' 5 x 8.5'=42.5' 4' SIX INCH CRUSHED STONE BASE, AS SPECIFIED 4' OF NATURALLY OCCURRING EFFECTIVE LENGTH = 50.5' IN 310 CMR 15.221(2). PERVIOUS MATERIAL 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 5' (MIN.) ABOVE G.W. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE LEACHING SYSTEM SECTION AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. BOTTOM OF TP, EL.=87.5 SEPTIC SYSTEM PROFILE SOIL LOG GENERAL NOTES: DATE: FEBRUARY 10, 2021 (REF#TPT-21-023) 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL SOIL EVALUATOR: PETER McENTEE SE#1542 BOARD OF HEALTH AND THE DESIGN ENGINEER. WITNESS: DAVID STANTON R.S. HEALTH AGENT 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS ELEV. TP- 1 DEPTH ELEV. TP-2 DEPTH OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 99.0 A 0 100.0 A 0" 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR LOAMY SAND LOAMY SAND TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 10YR 4/2 10YR 4/2 DESIGN ENGINEER. 98 5 B 6„ 99.5 B 6" 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING LOAMY SAND LOAMY SAND FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN 10YR 5/8 10YR 5/8 ENGINEER BEFORE CONSTRUCTION CONTINUES. 96.3 32" 97.0 36" _ 5. ALL ELEVATIONS BASED ON .ASSUMED DATUM: C C "- _�._ .,r .,,.-- - -- -.�.. _ PERC 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF 30"/48" THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. M-C SAND M-C SAND ' 8. THERE ARE NO WELLS WITHIN 150' OF THE PROPOSED S.A.S. 2.5Y 6/6 2.5Y 6/6 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY 87.5 138" 87.5 138" THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING PERC RATE <2 MIN/IN. "C" HORIZON CONSTRUCTION. NO GROUNDWATER ENCOUNTERED 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. ELEV. TP-3 DEPTH ELEV. TP-4 DEPTH 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 99.0 A 0 100.0 A 0" 14. IT IS THE RESPONSIBILITY OF THE HOMEOWNER TO GET PERMISSION TO LOAMY SAND LOAMY SAND ABANDON OR REMOVE SEPTIC SYSTEM COMPONENTS ON ADJACENT 10YR 4/2 10YR 4/2 PROPERTIES. 98•5 B 6" 99•5 B 6" 15. ON MARCH 3, 2021, VERISON STATED THAT THE OLD TELEPHONE LOAMY SAND LOAMY SAND TRANSMISSION CORRIDOR WAS NEVER USED AND WOULD NOT BE USED. 10YR 5/8 10YR 5/8 VERIZON STATED NO OBJECTION TO THE PROPOSED WORK. 96.3 32" 97.0 36" C PERC C DESIGN CRITERIA 30"/48" NUMBER OF BEDROOMS: 4 (EXISTING) ADD 1 BR/UNIT FOR 6 M-C SAND M-C SAND SOIL TEXTURAL CLASS: CLASS I 2.5Y 6/6 2.5Y 6/6 DESIGN PERCOLATION RATE: <5 MIN/IN (0.74 GPD/SF LOADING RATE) DAILY FLOW: 660 GPD 88.5 126" 88.5 126" DESIGN FLOW: 660 GPD PERC RATE <2 MIN/IN. "C" HORIZON GARBAGE GRINDER: NO NO GROUNDWATER ENCOUNTERED LEACHING AREA REQUIRED: (660 GPD) = 891.9 SF .74 GPD/SF EXISTING SEPTIC TANK: 1500 GALLON CAPACITY PROPOSED SEPTIC TANK: 1000 GALLON H-20 CAPACITY PROPOSED DISTRIBUTION BOX: 1 INLET, 3 OUTLETS PROPOSED SEPTIC SYSTEM UPGRADE PLAN USE 5-500 GALLON LEACHING CHAMBERS IN SERIES SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES 33 & 35 HIRAMAR RD, HYANNIS, MA SIDEWALL AREA: 2(12.8' + 50.5') x 2 = 252.2 S.F. Prepared for: Quinn's Excavation, 39 Bog River Bend, Mashpee, MA 02649 BOTTOM AREA: 12.8' x 50.5' = 646.4 S.F. Engineering by: SCALE DRAWN JOB. NO. TOTAL AREA:...................................................... ....... 898.6 S.F. Engine@I"1119 Works, Inc. N.T.S. P.T.M. 322-20 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. DESIGN FLOW PROVIDED: 0.74 GPD/SF(898.6 SF) = 664.9 GPD (508) 477-5313 3/16/21 P.T.M. 2 Of 2