Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0063 BRIAR PATCH ROAD - Health (2)
63 Briar hatch. Foaa`' Osterville . P A = 143 035 ,kz�" 4 ok ch e � e " e o a COMMONWEALTH OF MASSACHUSETTS EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS DEPARTMENT OF ENVIRONMENTAL PROTECTION TITLE 5 OFFICIAL INSPECTION FORM NOT FOR VOLUNTAR SUBSURFACE SEWAGE DISPOSAL SYSTEM TOAME VED PART A CERTIFICATION JUN 2 4 2002 BARNABLE Property Address: 63 Briar Patch Road TOWN HE�ALTH DEPT. Osterville, MA.02655 Owner's Name: Louis Mann Owner's Address: Same 1�. Date of Inspection: June 12, 2002 Name of Inspector: (Please Print) James M. Ford Company Name: James M. Ford Mailing Address: P.O. Box 49 Map: 143 Osterville,MA 02655-0049 Parcel: 035 Telephone Number: (508) 862-9400 Lot: 13 CERTIFICATION STATEMENT I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate and complete as of the time of the inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000). The system: ✓ Passes Conditionally Passes N urther Evaluation by the Local Approving Authority Fai s Inspector's Signature: Date: June 18, 2002 The system inspector shall submi copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable,and the approving authority. Notes and Comments ****This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different it conditions of use. Title 5 Inspection Form 6/15/2000 page I Page 2 of 11 E OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 63 Briar Patch Road Osterville, M4 Owner: Louis Mann Date of Inspection: June 12, 2002 Inspection Summary: Check A,B,C,D or E/ALWAYS complete all of Section D A. System Passes: ✓ I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: B. System Conditionally Passes: One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The'system,upon completion of the replacement or repair,as approved by the Board of Health,will pass. Answer yes,no or not determined(Y,N,ND)in the for the following statements. If"not determined",please explain. The septic tank is metal and over 20 years old* or the septic tank(whether metal or not)is structurally unsound,exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ND explain: Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken,settled or uneven distribution box. System will pass inspection if (with approval of Board of Health): broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced ND explain: The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed ND explain: M i 2 Page 3 of 11 OFFICIAL INSPECTION FORM NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 63 Briar Patch Road Osterville, AM Owner: Louis Mann Date of Inspection: June 12, 2002 C. Further Evaluation is Required by the Board of Health: Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health,safety or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health,safety and the environment: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh 2. System will fail unless the Board of Health(and Public Water Supplier,if any)determines that the system is functioning in a manner that protects the public health,safety and environment: The system has a septic tank and soil absorption system (SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. - The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. _ The system has,a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well". Method used to determine distance "This system passes if the well water analysis,performed at a DEP certified laboratory, for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: 3 Page 4 of 1 I OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 63 Briar Patch Road Osterville, AM Owner: Louis Mann Date of Inspection: June 12, 2002 D. System Failure Criteria applicable to all systems: You must indicate either`yes"or"no"to each of the following for all inspections: Yes No ✓ Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ✓ Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool _ ✓ Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ✓ Liquid depth in cesspool is less than 6"below invert or available volume is less than ''/z day flow ✓ Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped— _ ✓ Any portion of the SAS,cesspool or privy is below high ground water elevation. ✓ ! Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ✓ Any portion of a cesspool or privy is within a Zone I of a public well. ✓ Any portion of a cesspool or privy is within 50 feet of a private water supply well. ✓ Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form.] No (Yes/No)The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E. Large System: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd• You must indicate either`yes"or"no"to each of the following: (The following criteria apply to large systems in addition to the criteria above) Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply _ the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area IWPA)or a mapped Zone II of a public water supply well If you have answered"yes"to any question in Section E the system is considered a significant threat,or answered "Yes" in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 4 Page 5 of 11 OFFICIAL INSPECTION FORM -NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 63 Briar Patch Road Osterville, AM Owner: Louis Mann Date of Inspection: June 12, 2002 Check if the following have been done: You must indicate`yes"or"no"as to each of the following: Yes No ✓ _ Pumping information was provided by the owner,occupant,or Board of Health ✓ Were any of the system components pumped out in the previous two weeks? ✓ Has the system received normal flows in the previous two week period? ✓ Have large volumes of water been introduced to the system recently or as part of this inspection ? ✓ _ Were as built plans of the system obtained and examined?(If they were not available note as N/A) ✓ Was the facility or dwelling inspected for signs of sewage back up? ✓ _ Was the site inspected for signs of break out? ✓ _ Were all system components,excluding the SAS,located on site? ✓ _ Were the septic tank manholes uncovered,opened,and the interior of the tank inspected for the condition of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum ? ✓ Was the facility owner(and occupants if different from owner)provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System(SAS)on the site has been determined based on: Yes No ✓ Existing information. For example,a plan at the Board of Health. ✓ _ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable).[310 CMR 15.302(3)(b)]. M 5 Page 6 of i 1 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 63 Briar Patch Road Osterville, MA Owner: Louis Mann Date of Inspection: June 12, 2002 FLOW CONDITIONS RESIDENTIAL Number of bedrooms(design): 3 Number of bedrooms(actual): 3 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330 Number of current residents: 2 Does residence have a garbage grinder(yes or no): No Is laundry on a:separate sewage system (yes or no): No [if yes separate inspection required] Laundry system inspected(yes or no): No Seasonal use(yes or no): Yes Water meter readings, if available(last 2 years usage(gpd)): 2001 -26,000 gals.; 2000 32,000 gals.- Sump Pump(yes or no): No Last date of occupancy: Currently occupied COMMERCIAL/INDUSTRIAL Type of establishment: Design flow(based on 310 CMR 15.203): gpd Basis of design flow(seats/persons/sgft,etc.): Grease trap present(yes or no): Industrial waste holding tank present(yes or no) Non-sanitary waste discharged to the Title 5 system(yes or no): Water meter readings,if available: Last date of occupancy/use: OTHER(describe): GENERAL INFORMATION Pumping Records Source of information: Never pumped-per owner Was system pumped as part of the inspection(yes or no): No-owner was pumping after inspection If yes, volume pumped: gallons--How was quantity pumped determined? Reason for pumping: TYPE OF SYSTEM ✓ Septic tank,distribution box, soil absorption system Single cesspool Overflow cesspool Privy Shared system(yes or no) (if yes,attach previous inspection records,if any) Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) Tight Tank Attach a copy of the DEP approval Other(describe): Approximate age of all components,date installed(if known)and source of information: h Mar. 22184-per as built card Were sewage odors detected when arriving at the site(yes or no): No 6 Page 7 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM . PART C SYSTEM INFORMATION (continued) Property Address: 63 Briar Patch Road Osterville, AM Owner: Louis Mann Date of Inspection: June 12, 2002 BUELDING SEWER(locate on site plan) Depth below grade: Approx. 28 Materials of construction: _cast iron ✓ 40 PVC _other(explain): Distance from private water supply well or suction line: Comments(on condition of joints,venting,evidence of leakage,etc.): SEPTIC TANK: ✓ (locate on site plan) Depth below grade: Approx. 16" Material of construction: ✓ concrete _metal _fiberglass _polyethylene _other(explain) If tank is metal list age: Is age confirmed by a Certificate of Compliance(yes or no): (attach a copy of certificate) Dimensions: 1000 gal. Sludge depth: 4" Distance from top of sludge to bottom of outlet tee or baffle: 28" Scum thickness: 10" Distance from top of scum to top of outlet tee or baffle: 10" Distance from bottom of scum to bottom of outlet tee or baffle: 4" How were dimensions determined: Measuring stick Comments(on pumping recommendations, inlet and outlet tee or baffle condition,structural integrity, liquid levels as related to outlet invert,evidence of leakage,etc.): Tees were present The liquid level was even with the outlet invert. There were no signs of leakage. Recommend pumping. GREASE TRAP: None (locate on site plan) Depth below grade: Material of construction: _concrete _metal _fiberglass polyethylene _other (explain): 4 Dimensions: Scum thickness: Distance from top of scum to top of out tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle: Date of last pumping: Comments(on pumping recommendations,inlet and outlet tee or baffle condition,structural integrity,liquid levels as related to outlet invert,evidence of leakage,etc.): I 7 I Page 8 of I 1 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 63 Briar Patch Road Osterville, MA Owner: Louis Mann Date of Inspection: June 12, 2002 TIGHT or HOLDING TANK: None (tank must be pumped at time of inspection)(locate on site plan) Depth below grade: Material of construction: _concrete _metal, _fiberglass _polyethylene _other(explain): Dimensions: Capacity: gallons Design Flow: gallons/day Alarm present(yes or no): Alarm level: Alarm in working order(yes or no): Date of last pumping: Comments(condition of alarm and float switches,-etc.): DISTRIBUTION BOX: ✓ (if present must be opened)(locate on site plan) Depth of liquid level above outlet invert: Even Comments(note if box is level and distribution to outlets equal,any evidence of solids carryover,any evidence of leakage into or out of box,etc.): The D-box was level. There were no signs of solids. PUMP CHAMBER: None locate on site plan) ( P ) Pumps in working order(yes or no): Alarms in working order(yes or no) Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.): 8 Page 9 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 63 Briar Patch Road Osterville, AM Owner: Louis Mann ' Date of Inspection: June 12, 2002 SOIL ABSORPTION SYSTEM(SAS): ✓ (locate on site plan,excavation not required). If SAS not located explain why: Type ✓ leaching pits,number: 6'x 6'with 3'stone-per design plans leaching chambers,number: leaching galleries,number: leaching trenches,number,length: leaching fields,number,dimensions: overflow cesspool,number: Innovative/alternative system Type/name of technology: Comments(note condition of soil,signs of hydraulic failure, level of ponding,damp soil,condition of vegetation, etc.): The pit had approximately 1'ofwater on the bottom. The scum line was at the same level. There were no signs offailure. The bottom to grade was approximately 9' The cover was approximately Y below grade. CESSPOOLS: None (cesspool must be pumped as part of inspection)(locate on site plan) Number and configuration: Depth -top of liquid to inlet invert: Depth of solids layer: Depth of scum layer: Dimensions of cesspool: Materials of construction: Indication of groundwater inflow(yes or no): Comments (note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.): PRIVY: None (locate on site plan) Materials of construction: Dimensions: Depth of solids: Comments(note condition of soil, signs of hydraulic failure, level of ponding,condition of vegetation,etc.): 9 Page 10 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 63 Briar Patch Road Osterville, MA Owner: Louis Mann Date of Inspection: June 12, 2002 Map: 143 Parcel: 035 SKETCH OF SEWAGE DISPOSAL SYSTEM Lot. 13 Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. A, - a� , Q P Aa- � 3 a i Ay- 1 54 y r 10 r Page 11 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 63 Briar Patch Road Osterville, AM Owner: Louis Mann Date of Inspection: June 12, 2002 SITE EXAM Slope Surface water Check cellar Shallow wells Estimated depth to ground water 36' feet Please indicate (check)all methods used to determine the high ground water elevation: Obtained from system design plans on record- If checked, date of design plan reviewed: ✓ Observed site(abutting property/observation hole within 150 feet of SAS) Checked with local Board of Health-explain: Checked with local excavators,installers-(attach documentation) Accessed USGS database-explain: You must describe how you established the high ground water elevation: The bottom of the leach pit to grade was approximately 9. Using the Barnstable topographic man and the Cape Cod Commission water contours maps the maps were showing approximately 36'+/-to ground water at this site. I This report has been prepared and the.system inspected and passed as of the date of inspection. This report is not a warranty or guarantee that the system will function properly in the future. There have been no warranties or guarantees, either expressed, written or implied, relating to the system, the inspection and/or this report. f 11 No: 3..:I F&$...1_°............... THE COMMONWEALTH OF MASSACHUSETTS MAP 143 � BOAR® OF HEALTH PARCEL ` ®3 �(...,P.. 1\..............oF...........-....#�k.. 2-.1. .. ..?_ _. .4 .......... ApplirFation for Disposal Vorkg Tonstrurtion Prrutit Application is hereby made for a Permit tp Construct ( ✓) or Repair ( } an Individual Sewage Disposal System at: �`3 � erX ....!-.d.?'_l ._. ... ....i;!A 115 I .E.ill�_ Location-Address or:--•------------- ------k1 1?�t? t ..o.. "..At�lN.i�..t.M..�. owner. d re --------------------------------- zi /-� ------------------------------------------- Installer Address Type of Building Size Lot......lj,t,tl ----Sq. feet . � Dwelling—No. of Bedrooms..................;5 .......................... Attic ( ) Garbage Grinder ( ) Other—T e of Building •....._...._ No. of persons............................ Showers a —Type g --- --•- p ( ) — Cafeteria ( ) Otherfixtures --------•--•---------•---------•--------- ........................................................................................................... w Design Flow.............. .1r_......................gallons per person per day. Total daily flow..........33`d-•----•----__:......gallons. WSeptic Tank—Liquid*capacity_RjgU.gallons Length._-.�T*17e-_- Width................ Diameter---------------- Depth................ x Disposal Trench—No. .................... Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No--------------------- Diameter...l ----------- Depth below inlet....r7............ Total leaching area.34d.:.Q.sq. ft. Z Other Distribution box ( ✓) Dosing tank Percolation Test Results Performed by....JA/A4.... . _--1. . .kekL....... Date.•.....J.P.`_fg':.r!?��........ 21014' Test Pit No. 1..__...2'_....minutes per inch Depth of est Pit___________________ Depth to ground water.... (i Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ 0 Description of Soil----••...4•--.1.V..... y by `Jtv !�.--•• - t r c., -------------------------------------------------------------- ----------------------------------------------------- ----------------•-----...:-•-----------•••--•••••..........--••••-- w UNature of Repairs or Alterations—Answer when applicable............................................................................................... -•--------------------------------•..------•----------•---------------------•-•••-•••--............••••••••••-•----•---------•-----••••-•••••-••---••-•-•••--•------••-•••-•-•••••-••••••••-•--.....•••. Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of THT4 YIE 5 of the State Sanitary Code— TIA undersigned further agrees not to place the system in operation until a Certificate of Compliance has bee �'ss d t oard of health. Signed.__. %u _-. /D ......� ate ApplicationApproved By-•••-•-••-•-•--•--•---•-••••••••--...••••-••-•-•-......•••---••..........................•-••••-• ............................... Date Application Disapproved for the following reasons-----------------------•----••---•-----••------------•--•----•--------------------------------•--•-•-......--.... .......................................••--.•••••-•----••-•--•--•••••-••-•••-••••-••--••--•-••-••••------••••••-•--•••••--------•-•-----••••---•••--------•--•••-•••---•------••......-•--•••.....---•- Date PermitNo......................................................... Issued-....................................................... Date n.f ..... 0 Fns............................. THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH ..U..../LJ l..................OF.............. L Appliratiun for Biupuual Works Tonutrurtiun omit Application is hereby made for a Permit to Construct (✓) or Repair ( ) an Individual Sewage Disposal System at: ...!. 1._.� _.�..•� A A.. �...�.�........-•---... �`�i .L\lI L1'� -�A--ZNS-( >--L� , /Vi-�_ Location-Address or Lot No. ><r '/_L r/�4----------------- .!. _ �Cl-.t..._.fz • k=>!�1 �1�v •- M_ . ... .................- �. . Owner Address W ,-� ••---------•-----•.....................•---•-----•-------•--..........---•-•------•-••--•------•-- ----........_......-----•-•-•-•-•--------...............--••----...--=......--::----•S•--•'feet Installer Address Type of Building Size Lot.....��[7 _`l?.... q. U Dwelling—No. of Bedrooms............................................Expansion Attic ( ) Garbage Grinder ( ) aOther—Type of Building .._ ............... No. of persons............................ Showers ( ) — Cafeteria ( ) Otherfixtures .---••-••----•• -•-•-•---••-••---•---•--......-•---•.............••-••...---•---------------------................................................ W Design Flow.............`�.�..._.______..._.__...__...gallons per person per day. Total daily flow.__.......-�`�_------_--•-.-............gallons. WSeptic Tank—Liquid capacity�l L gallons Length-.' J_-V:.... Width................ Diameter................ Depth................ x Disposal Trench—No..................... Width................... Total Length.................... Total leaching area....................sq. ft. 3 Seepage Pit No....._..I------------ Diameter.._[............. Depth below inlet.... ..__._._..... Total leaching area !�11 V..sq. ft. z Other Distribution box (✓) Dosing tank ( ) Percolation Test Results Performed by.... 1�1.:__lrl/f . _S.!!�.��._.'�._. 1.'�(1........ Date....... P 4- Test Pit No. 1......k.....minutes per inch Depth of Test Pit----�_�.......... Depth to ground water...t�l..&_NE (� Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ Q+' •-------•---- --- _ -- ............. ..... ... ..;; vN\.. � .. . �I O Description of Sail---.- ....... (............Iq ` - ---. _ ___ __ x V ..............•-------••-••-•----•--•-•-•---•---•---••--••••-•--•••••--•-•••---•--.....__...._...................------------ W ---------------.......................................................................................-•-•--•--------------------•---------•••--•--------•-------------•-••--•---••--------•---.-•---- V Nature of Repairs or Alterations—Answer,when applicable................................................................................................ --------•-------------•----------------------------------------•--•------------------•--.............---....------•-----------------.....------------......-----------------------------------.....---•- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of T iT f,i"• p 5 of the State Sanitary Code The undersigned further agrees not to place the system in operation until a Certificate of Compliance has been issued by the board of health. Signed....................................................................................... Date ApplicationApproved By.......................................... ...................................................... ....................................... Date Application Disapproved for the following reasons---------------------------------------------------------------•----------------------------•-•-••--------...._.. ---------------------------•-•---....------....---...----•--•--------------------.•......-----------...--••-----------------•-•-•----••-----•-------------------••---••---------•-----•••-•--.....--•--- Date PermitNo......................................................... Issued....................................................... Date THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH ...........I.............I................OF..................................................................................... Trrtifiratr of Tomplitinre THIS IS TO CERTIFY, That the Individual Sewage Disposal System constructed ( ) or Repaired ( ) by................................................................................---•----------•--- -•••-------•------....._...----------------•-----•------•.......---•---•----••----••--•-----•... Installer at...............................................•---------•---------------•-------------------------- has been installed in accordance with the provisions of TITLE j of The State Sanitary Code as described in the application for Disposal Works Construction Permit No......................................... dated................................................ THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUE S A GUARANTEE THAT THE SYSTEM WILL F ION SATISFACTORY. DATE. . ._. Inspector---- - ------------------- THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH - .....................OF..--•-.--------...............--•---....--------................................... No. 3 FEE........................ Ru11uuaU urLk�u Tonutimtiun rrmit Permission is hereby granted.---------•--•.W�-k/_-------H/i X� ....--•--•------------•---.-••........................................•--- (��)to Construct ' or Repair ( ) an Indiv idual Sewage Disposal System atNo....kO--'t-'- .....13.--------._�YZ-l_K&.:.......- +f' "C. ..---•--.-------------------------------------------•-----------------------------------....-•------••-- Street as shown on the application for Disposal Works Construction Permit No..................... Dated.......................................... e`�------------------------------•---•-•-•----....------..............---- Board of Health � _: _ ►DATE......_�_... , FORM 1255 HOBB'�S & WARREN. INC., PUBLISHERS S/TE FL A l ' TYPICAL PROFILE a Nor rol SCALE SCALE — l " = o' I �� 5 s - 18"STD LT WGT C.l. aw COVER zy I 4"C I. P/PE ____r T. 4' BIT. F/B£R PIP£ TIGHT JOINTS , rl FLOW LINE LEVEL _ TO FIRST JOINT DWELLING �Ic 14 o C.I. TEE _ _.. C./. TEE - "�". _.__._. STANDARD PRECAST f 4 CONCRETE IvoDGAL LON $, v� __.. SEPTIC 7 ANK .. 0/5 TRIBU TION BOX f TO BE INSTALLED ON LEVEL, STABLE BASE. j SEPTIC' TANK ~ TO 8E INSTALLED ON i LEVEL , STABLF BASE iI 2"- 1.%8 TC I;'2 WASHED PEA STONF AL� A.ROUNO FREE OF IRONS, FINES LEACH/NC, f'/T A n,', DUST /N PLACE BASE TO BE LEVEL t BRICK map T";H U✓RES - 3/4 ' TO /-//2' WASHED CRUStiF_r? - r.+ ' AS REOVIRED TO BRING y, PLO - STONE ALL AROUND FREE OF I?- COVER TO GRADE 24"C.I. MH COVER AND FRAME IRONS, FINES AND DUST /N !'LACE G STD, t�R> .>:+j' G. „�_ �4� �_ —�— , 'I © ��., _ L � LEACHING PIT SECTION— �aEPT{� TA!.: INLET 8 FLOW LINE ----- --- - Zo --r P/PF �— I. CONCRETE TO BE 4000 PSI 28 DAYS -" `* Iv IN - �„ r 2. REINFORCED WITH 6" x 6" NO 6 GA. W.W.M. { _ Y to t 3. 2' AND 4' SECTIONS ARE AVAILABLE FOR GREATER SDP. Df� i 11 ' 1 DEPTH REQUIREMENTS. OPENING W/TH 4-1/8 j 4. NUMBER OF PITS REQUIRED POE OUTER DIAMETER 8 ! zoi. a Q NOTE. EXCAVATE TO ELEVATION OR LOWER AS �, + 1-3/4 INSIDE D/A METER 3,� I REQUIRED TO REMOVE ALL LOAM AND CLAY BENEATH ' I PIT REPLACE EXCAVATEC MATERIAL WITH CLEAN GRAVEL TO DESIGNED GRADE . i Z' L©T 1 '1 I I1 tA MIN. , { -FFFCTIVE DIAME TEG' 1- ' ©' (NOT TO EXCEED 3 TIMES EFFECTIVE DEPTH) --� f Ill 7-1-42 4`J, �-c.. WATER TABLE . .... �- , �. •.���. .._��� - A T 9 L,.. -z-1 . v T tz . C/L ND f'Err ZJ A FAGENERAL NOTES �}D V-/ ! PI- ) PERG. RATE MIN. /ICI , NO HEAVY EQUIPMENT TO RUN OVER SYSTEM SEPTIC TANK, CISTRIBUTION BOX , LEACHING PITS TO BE STANDARD TEST BY: .._._`�` �uU{GIB. :• �ahAG• , ___._ � `'► _ _._ --__- PRECAST REiNF!)R.CEC CONCRETE UNITS. ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITNESSED BY �.��'� ►.1 ._�l.L�:_r?3 ?1 _--_ .._ —.. -- TO REVISED TITLE 5 OF THE STATE ENVIRONMENTAL CODE , TEST PIT GR. EL'`}I ' ___ DATE' 4D" Iq"_ MINIMUM REQUIREMENTS FOR THE SUBSUFACE DISPOSAL OF TEST PIT NO. FZ4aIl-� TEST PIT NO. 2 SANITARY SEWAGE EFFECTIVE I JULY 1977. 0': - - --�� O'l� ----- ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AT COMPLETION OF CONSTRUCTION , PRIOR TO BACKFILLtNG, THE BOARG OF HEALTH SHALL BE NOTIFIED FOR INSPECTION. tAQD PITCH ALL SEWER LINES 1/4" / FT. UNLESS INDICATED OTHERWISE. C cw vI J.I C>V/A I DESIGN DAT4 - -- BFDROOMS _�?____- DISPOSAL— EST. TOTAL DAILY EFF ___ r3v GALS. LEGEND —" SEPTIC TANK ;vva GAL SIDEWALL AREA _ _2_—GAL./SQ. FT. BOTTOM AREA .o ___GAL./sQ: FT. SEWAGE DISPOSAL SYSTEM 4XCC EXISTING GRADE LEACHING REQUIRED_ I`'I"'- '��' S©.FT. " ` ACTUAL LEACHING AREA _��'_L`._SQ.FT. FOR ZONE' -.__iZL- _---_.—_._ L3 0o FINISHED GRADE DOMESTIC WATER SOURCE o. 00 INVERT ELEVATION _•' _9, c ;` - � .•` L --- �T1•- L_t - �' � >>r L� _-- -- - PROPERTY LINE 4-111 ' !! d�-ryrzy.IL.L.r � 95p,A 2 1..1�l�w ��4'~ , hM A. PLAN REFERENCE ' IT'D Zy<� >a� �43 — �; -,,�. , t p %zZ- -- ---- MEAN HIGH WATER SCALE' AS INDICATED DATE : r 1 ►3 BENCH MARK DATUM MARSH vVM. M. bVi4RWIC/{ a ASSOC/AYES BOX 801 - NORTH FALMOUTH v,4-SS4"HUSE 7 02556