Loading...
HomeMy WebLinkAbout0010 DEERFIELD ROAD - Health 10 Deerfield Road 166-075 Osterville Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE I/ MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important:When A. Inspector Information filling out forms on the computer, use only the tab Christopher Maki key to move your Name of Inspector cursor-do not Cape Cod Septic Services use the return key. Company Name 350 Main St. Company Address W Yarmouth MA 02673 City/Town State Zip Code resrn 508-775-2825 SI-14423 Telephone Number License Number B. Certification I certify that: I am a DEP approved system inspector In full compliance with Section 15.340 of Title 5 (310 CMR 15.000); 1 have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems.After conducting this inspection I have determined that the system: 1. ® Passes 2. ❑ Conditionally Passes 3. ❑ Needs Further Evaluation by the Local Approving Authority 4. ❑ Fails 9/9/2020 'Irrs ector' Ss Ignalp erg Date The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP) within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note: This report only describes conditions at the time of inspection and under the .conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 1 of 18 Commonwealth of Massachusetts �y Title 5 Official Inspection Form Subsurface Sewage Disposal System Form= Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection C. Inspection Summary Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6. 1) System Passes: ® 1 have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: SYSTEM IS IN WORKING CONDITION r 2) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no" or"not determined" (Y, N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old* or the septic tank(whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND(Explain below): l5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) 2) System Conditionally Passes (cont:): ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND(Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below): ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND(Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below): . .3) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. a. System will pass unless Board of Health determines-in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: l5insp.doc rev.7/26/2018 Title 6 Official Inspection Form;Subsurface Sewage Disposal System•Page 3 of 18 Commonwealth.of Massachusetts - , Title 5 Official Inspection Form J. Subsurface Sewage Disposal System Form- Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 _ _-_-_- page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh b. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has aseptic tank and soil absorption system (SAS) and the SAS is within 100 feet of a surface.water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance: ** This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or!less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must indicate "Yes" or"No"to each of the following for all Inspections: i Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form to .Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No 0 ED Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than '/z day flow ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high groundwater elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes If the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis and chain of custody must be attached to this form.) ® The system is a cesspool serving a facility with a design flow of 2000 gpd- 10,000 gpd. ❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems: To be considered a large system the system'must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no"to each of the following, in addition to the .questions in Section CA. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area—IWPA) or a mapped Zone II of a public water supply well t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 18 „ Commonwealth of Massachusetts 1p Title 5 Official Inspection Fora Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) If you have answered "yes” to any question in Section C.5 the system is considered a significant threat, or answered"yes"to any question in Section CA above the large system has failed. The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6. You must indicate "yes" or"no"for each of the following for all inspections: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ® ❑ Has the system received normal flows in the previous two week period? Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined? (If they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up?. ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ® ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form �o Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection D. System Information 1. Residential Flow Conditions: Number of bedrooms (design): 3 Number of bedrooms(actual): 3 DESIGN flow based on 310 CMR 15.203 (for example:110 gpd x#of bedrooms): 330 Description: Number of current residents: SEASONAL Does residence have a garbage grinder? ❑ Yes ® No Does residence have a water treatment unit? ❑ Yes ® No If yes, discharges to: Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No information in this report.) Laundry system inspected? ❑ Yes ® No Seasonal use? ® Yes ❑ No Water meter readings, if available (last 2 years usage(gpd)): '19-224 GPD '18-249 GPD Detail: Sump pump? ❑ Yes ® No Last date of occupancy: SEASONAL Date t8insp.doc-rev.7/26/2018 Title 6 Official Inspection Form:Subsurface Sewage Disposal System Page 7 of 18 Commonwealth of Massachusetts --, Title 5 Official Inspection Form _ is Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE_ MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 2. Commercial/Industrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15.203): Gallons per day(gpd) Basis of design flow (seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ❑ No Water treatment unit present? ❑ Yes ❑ No If yes, discharges to: Industrial waste holding tank present? ❑ Yes ❑ No• Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: Last date of occupancy/use: Date Other(describe below): 3, Pumping Records: Source of information: N/A Was system pumped as part of the inspection? ❑ Yes ® No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: t5insp.00c•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 8 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 _ page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 4. Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank. Attach a copy of the DEP approval. ❑ Other(describe): Approximate age of all components, date installed (if known)and source of information: Were sewage odors detected when arriving at the site? ❑ Yes ® No 5. Building Sewer(locate on site plan): Depth below grade: 1911 feet Material of construction: ❑ cast iron ® 40 PVC ❑ other(explain): Distance from private water supply well or suction line. feet Comments (on condition of joints, venting, evidence of leakage, etc.): LINE CHECKED WITH SEWER CAMERA AND WAS FOUND TO BE CLEAN AND PROPERLY PITCHED t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 9 of 18 Commonwealth of Massachusetts - Title 5 Official Inspection Form IQ Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 6. Septic Tank (locate on site plan): Depth below grade: 12"feet Material of construction: ® concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No Dimensions: 1000 GALLONS Sludge depth: 211 Distance from top of sludge to bottom of outlet tee or baffle Scum thickness 1" .Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle How were dimensions determined? ESTIMATED Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 1000 GALLON TANK IN GOOD CONDITION. PVC TEES IN PLACE AND CLEAN. TANK AT NORMAL OPERATING LEVEL. COVERS 12" BELOW GRADE. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System Page 10 of 18 cam, Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 7. Grease Trap (locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom.of scum to bottom of outlet tee or baffle Date of last pumping: Date Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 8. Tight or Holding Tank (tank•must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑other(explain): Dimensions: Capacity: gallons , Design Flow: gallons per day t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form �a Subsurface Sewage Disposal System Form Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 8. Tight or Holding Tank(cont.) Alarm present: ❑ Yes ❑ No Alarm level: Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments (condition of alarm and float switches, etc.): *Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No 9. Distribution Box(if present must be opened) (locate on site plan): Depth of liquid level above outlet invert EVEN Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): DISTRIBUTION BOX LEVEL AND WATERTIGHT t5insp doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Fora Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORG'IA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 10. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No* Alarms in working order: ❑ Yes ❑ No* Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): *If pumps or alarms are not in working order, system is a conditional pass. 11. Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: Type: ® leaching pits number: 1-6X6 PIT ❑ leaching chambers number: . ` ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: t5insp.doc-rev.7/28/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 13 of 18 c Commonwealth of Massachusetts -- ig Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments L:= 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE MA 02655 8/28/2020 page., City/Town State Zip Code Date of Inspection D. System Information (cont.) 11. Soil Absorption System (SAS) (cont.) Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition.of vegetation, etc.): 1-6X6 PIT WITH STONE FOUND DRY DURING INSPECTION WITH NO EVIDENT STAINING. 12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth —top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow ❑ Yes ❑ No Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Ji Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is OSTERVILLE MA 02655 8/28/2020 required for every —. page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 13. Privy(locate on site plan): Materials of construction: Dimensions Depth of solids Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): r t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form I; Subsurface Sewage Disposal System Form -Not for Voluntary Assessments �t J; 10 DEER:FIELD RD Property Acdress GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name Informrequired tion is OSTERVILLE MA 02655 8/28/2020 required for every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 14. Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the b gilding. Check one of the boxes below: ❑ hand-sketch in the area below ® drawing attached separately t5insp.doc-rev.7/2 612 0 1 8 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 18 Commonwealth of Massachusetts ---, Title 5 Official Inspection Form i5 Subsurface Sewage Disposal System Form -Not for Voluntary Assessments j; 10 DEERFI_ELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name information is required for every OSTERVILLE _MA 02655 8/28/2020 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 15. Site Exam: ® Check Slope ® Surface water ® Check cellar ® Shallow wells Estimated depth to high ground water: +11'feet Please indicate all methods used to determine the high ground water elevation: ❑ Obtained from system design plans on record If checked, date of design plan reviewed: Date ® Observed.site (abutting property/observation hole within 150 feet of SAS) ❑ Checked with local Board of Health-explain: ❑ Checked with local excavators, installers-(attach documentation) ❑ Accessed USGS database-explain: You must describe how you established the high ground water elevation: HAND AUGER 4' BELOW DRY PIT WITH NO GROUNDWATER ENCOUNTERED Before filing this Inspection Report, pleases 'e Report Completeness'Checklist on next page. t5insp.doc•rev.7/2612018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 17 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 10 DEERFIELD RD Property Address GEORGIA GEFTEAS-14 MACARTHUR RD WELLESLEY MA 02482 Owner Owner's Name Information is OSTERVILLE MA 02655 8/28/2020 required for every ___ ___.____—_.__ page. City/Town State Zip Code Date of Inspection E. Report Completeness Checklist Complete all applicable sections of this form.inclusive of: ® A. Inspector Information: Complete all fields in this section. ® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked ® C. Inspection Summary: 1,2, 3, or 5 completed as appropriate 4 (Failure Criteria) and 6 (Checklist)completed ® D. System Information: For 8: Tight/Holding Tank—Pumping contract attached For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 18 of 18 L 3 , R Q 33 .3aaya �L i COMMONWEALTH OF MASSACHUSETTS EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS DEPARTMENT OF ENVIRONMENTAL PROTECTION RECEIVED MAR 2 3 2004 TOWN OF BARNSTABLE HEALTH DEPT. TITLE 5 OFFICIAL INSPECTION FORM- NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM PART A CERTIFICATION MAP Property Address: 10 Deerfield Drive o � PARCEL Osterville, MA 02655 Owner's Name: William Tillman LOB 5 _ Owner's Address: Date of Inspection: February 28, 2004 Name of Inspector: (Please Print) James M. Ford Company Name: James M. Ford Mailing Address: P.O. Box 49 Ostervllle,MA 02655-0049 Telephone Number: (S08) 862-9400 CERTIFICATION STATEMENT I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true,accurate and complete as of the time of the inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000). The system: ✓ Passes Conditionally Passes Needs 'her Evaluation by the Local Approving Authority r Fails Inspector's Signature: Date: March 4, 2004 The system inspector shall4submiaf this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable,and the approving authority. Notes and Comments ****This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions,of use. Title 5 Inspection Form 6/15/2000 page I Page 2 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 10 Deerfield Drive Osterville, AM Owner: William Tillman Date of Inspection: February 28, 2004 Inspection Summary: Check A,B,C,D or E/ALWAYS complete all of Section D A. System Passes: ✓ I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: B. System Conditionally Passes: One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The system,upon completion of the replacement or repair,as approved by the Board of Health, will pass. Answer yes,no or not determined(Y,N,ND)in the for the following statements. If"not determined",please explain. The septic tank is metal and over 20 years old* or the septic tank(whether metal or not) is structurally unsound,exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ND explain: Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will pass inspection if (with approval of Board of Health): broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced ND explain: The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed ND explain: 2 Page 3 of 11 OFFICIAL INSPECTION FORM - NOT FOR,VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 10 Deerfield Drive Osterville, MA Owner: William Tillman Date of Inspection: February 28, 2004 C. Further Evaluation is Required by the Board of Health: Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health,safety or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health,safety and the environment: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh 2. System will fail unless the Board of Health(and Public Water Supplier,if any)determines that the system is functioning in a manner that protects the public health,safety and environment: _ The system has a septic tank and soil absorption system (SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and SAS and the SAS is within a Zone I of a public water supply. The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well". Method used to determine distance "This system passes if the well water analysis,performed at a DEP certified laboratory, for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,'provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: 3 f Page 4 of 11 OFFICIAL INSPECTION FORM- NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 10 Deerfield Drive Osterville, MA Owner: William Tillman Date of Inspection: February 28, 2004 D. System Failure Criteria applicable to all systems: You must indicate either"yes"or"no"to each of the following for all inspections: Yes No ✓ Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ✓ Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool. ✓ Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool' ✓ Liquid depth in cesspool is less than 6"below invert,or available volume is less than %day flow ✓ Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped_. ✓ Any portion of the SAS,cesspool or privy is below high ground water elevation. ✓ Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ✓ Any portion of a cesspool or privy is within a Zone 1 of a public well. _ ✓ Any portion of a cesspool or privy is within 50 feet of a private water supply well. _ ✓ Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. (This system passes if the well water analysis, performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form.] No (Yes(No)The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E. Large System: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd• You must indicate either"yes"or"no"to each of the following: (The following criteria apply to large systems in addition to the criteria above) Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinkingwater supply the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area- IWPA)or a mapped Zone II of a public water supply well If you have answered `yes to any question in Section E the system is considered a significant threat, or answered "yes"in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 4 Page 5 of 11 OFFICIAL INSPECTION FORM'- NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 10 Deerfield Drive Osterville, M4 Owner: William Tillman Date of Inspection: February 28, 2004 Check if the following have been done: You must indicate"yes or"no"as to each of the following: Yes No ✓ _ Pumping information was provided by the owner,occupant,or Board of Health ✓ Were any of the system components pumped out in the previous two weeks?' ✓ _ Has the system received normal flows in the previous two week period .9 ✓ Have large volumes of water been introduced to the system recently or as part of this inspection ? ✓ _ Were as built plans of the system obtained and examined?(If they were not available note as N/A) ✓ Was the facility or dwelling inspected for signs of sewage back up? ✓ _ Was the site inspected for signs of break out? ✓ _ Were all system components,excluding the SAS,located on site? ✓ _ Were the septic tank manholes uncovered,opened, and the interior of the tank inspected for the condition of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum ? ✓ _ Was the facility owner(and occupants if different from owner)provided with information on the proper maintenance of subsurface sewage disposal systems? \ The size and location of the Soil Absorption System(SAS)on the site has been determined based on: Yes No ✓ Existing information. For example,a plan at the Board of Health. ✓ _ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable)[310 CMR 15.302(3)(b)]. I 5 Page 6 of. 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 10 Deerfield Drive Osterville, Am Owner: William Tillman Date of Inspection: February 28, 2004 FLOW CONDITIONS . RESIDENTIAL Number of bedrooms(design): 3 Number of bedrooms(actual): 3 DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms): 330 Number of current residents: 2 Does residence have a garbage grinder(yes or no): No Is laundry on a separate sewage system(yes or no): No [if yes separate inspection required] Laundry system inspected(yes or no_): No Seasonal use(yes or no): No Water meter readings,if available(last 2 years usage(gpd)): Unavailable Sump Pump(yes or no): No Last date of occupancy: Currently occupied COMMERCIAL/INDUSTRIAL Type of establishment: Design flow(based on 310 CMR 15.203): gpd Basis of design flow(seats/persons/sgft,etc.): Grease trap present(yes or no): Industrial waste holding tank present(yes or no) Non-sanitary waste discharged to the Title 5 system (yes or no): Water meter readings, if available: Last date.of occupancy/use: OTHER(describe): i GENERAL INFORMATION Pumping Records Source of information: Unavailable Was system pumped as part of the inspection(yes or no): No If yes,volume pumped: _gallons--How was quantity pumped determined? Reason for pumping: TYPE OF SYSTEM ✓ Septic tank,distribution box,soil absorption system Single cesspool Overflow cesspool Privy Shared system (yes or no) (if yes,attach previous inspection records, if any) Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) Tight Tank Attach a copy of the DEP approval Other(describe): Approximate age of all components,date installed(if known)and source of information: Installed approximately 1979-per design plans Were sewage odors detected when arriving at the site(yes or no): No 6 4 A Page 7 of I 1 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 10 Deerfield Drive Ostenille AM Owner: William Tillman. Date of Inspection: February 28, 2004 BUILDING SEWER(locate on site plan) Depth below grade: Materials of construction: _cast iron _40 PVC other(explain): Distance from private water supply well or suction line: Comments(on condition of joints,venting,evidence of leakage,etc.): SEPTIC TANK: ✓ (locate on site plan) Depth below grade: 10,/ Material of construction: ✓ concrete _metal _fiberglass _polyethylene _other(explain) If tank is metal list age: Is age confirmed by a Certificate of Compliance(yes or no): (attach a copy of certificate) Dimensions: 1000 gal. Sludge depth: 2" Distance from top of sludge to bottom of outlet tee or baffle: 30" Scum thickness: 6" Distance from top of scum to top of outlet tee or baffle: 8" Distance from bottom of scum to bottom of outlet tee or baffle: 10" How were dimensions determined: Measuring stick Comments(on pumping recommendations, inlet and outlet tee or baffle condition,structural integrity, liquid levels as related to outlet invert,evidence of leakage,etc.): Tees were present. The liquid level was even with the outlet invert. There slid not appear to be any signs of leakage GREASE TRAP: None (locate on site plan) Depth below grade: Material of construction: _concrete ,metal _fiberglass _polyethylene _other (explain): Dimensions: Scum thickness: t Distance from top of scum to top of outlet tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle: Date of last pumping: Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert,evidence of leakage,etc.): 7 Page 8 of l 1 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 10 Deerfield Drive Osterville, AM Owner: William Tillman Date of Inspection: February 28 2004 P ry TIGHT or HOLDING TANK: None (tank must be pumped at time of inspection)(locate on site plan) Depth below grade: Material of construction: concrete metal _fiberglass _polyethylene _other(explain): Dimensions: Capacity: gallons Design Flow: gallons/day Alarm present(yes or no): Alarm level: Alarm in working order(yes or no): Date of last pumping: Comments(condition of alarm and float switches,etc.): DISTRIBUTION BOX: ✓ (if present must be opened)(locate on site plan) Depth of liquid level above outlet invert: Even Comments(note if box is level and distribution to outlets equal,any evidence of solids carryover, any evidence of leakage into or out of box,etc.): The D-box was level. No solids were present. PUMP CHAMBER: None (locate on site plan) Pumps in working order(yes or no): Alarms in working order(yes or no) Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.): 8 Page 9 of I 1 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 10 Deerfield Drive Osterville, AM Owner: William Tillman Date of Inspection: February 28, 2004 SOIL ABSORPTION SYSTEM(SAS): ✓ (locate on site plan,excavation not required) If SAS not located explain why: Type ✓ leaching pits,number: I - 6'x 6'w/]'stone(per design plans) leaching chambers,number: leaching galleries,number: leaching trenches,number, length: leaching fields,number,dimensions: overflow cesspool,number: Innovative/alternative system Type/name of technology: Comments(note condition of soil,signs of hydraulic failure, level of ponding, damp soil,condition of vegetation, etc.): The pit had 3'ofwater on the bottom. The scum line was at the same level. There did not appear to be any signs offailure. The bottom to grade was 9. CESSPOOLS: None (cesspool must be pumped as part of inspection)(locate on site plan) Number and configuration: Depth-top of liquid to inlet invert: Depth of solids layer: Depth of scum layer: Dimensions of cesspool: Materials of construction: Indication of groundwater inflow(yes or no): Comments (note condition of soil,signs of hydraulic failure, level of ponding,condition of vegetation,etc.): PRIVY: None (locate on site plan) Materials of construction: Dimensions: Depth of solids: Comments'(note condition of soil,signs of hydraulic failure, level of ponding,condition of vegetation,etc.): 9 E r Page 10 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 10 Deerfield Drive Osterville, MA - Owner: William Tillman Date of Inspection: February 28, 2004 SKETCH OF SEWAGE DISPOSAL SYSTEM Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. 3 a � � 3a ag -3 10 Page 11 of l l OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 10 Deerfield Drive Osterville, AM Owner: William Tillman Date of Inspection: February 28, 2004 SITE EXAM Slope Surface water Check cellar Shallow wells Estimated depth to ground water 40 +/- feet Please indicate (check) all methods used to determine the high ground water elevation: Obtained from system design plans on record- If checked, date of design plan reviewed: Observed site(abutting property/observation hole within 150 feet of SAS) v' Checked with local Board of Health-explain:topographic and water contours maps Checked with local excavators installers- attach documentation Accessed USGS database-explain: You must describe how you established the high ground water elevation: Using the Barnstable topographic map and the Cape Cod Commission water contours map,the maps were showing approximate!y 40'+/-to ground water at this site. This report has been prepared and the system inspected and passed as of the date of inspection. This report is not a warranty or guarantee that the system will function properly in the future. There have been no warranties or guarantees, either expressed, written or implied, relating to the system, the inspection and/or this report. 9 TQWN�]OF BARNSTABL.E !� LOCATION !O Du,� ' 13J ` RDA D SEWAGE # VILLAGE 0 rV)ItL ASSESSOR'S MAP & LOT INSTALLER'S NAME&PHONE NO. SEPTIC TANK CAPACITY t�A i LEACHING FACILITY: (type) �Ox 6� �, ! S7MR-(size) JOX GA ) NO.OF BEDROOMS 3 BUILDER OR OWNER Lam,1114M l i 11 m4q PERMITDATE: COMPLIANCE DATE: Separation Distance Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet Private Water Supply Well and Leaching Facility (If any wells eicist on site or within 200 feet of leaching facility) Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leacWn facility) l Feet Furnished by Til cc, �• ���` � w � o - ,cam w to C� 3 No................_....... Fss.............................. .a THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH ....Town.........................OF.........13ar..n Stabl.e.----------------.....................---------- Application is hereby made for a Permit to Construct (X ) or Repair ( ) an Individual Sewage Disposal System at: Lot # 56 Deerfield Road Osterville ................_ ............ ---_----•--•--•-•------------------.......--_.-•-- .................................................... ---------------------------..............-- oca o Address or Lot No. Robert F. k9tk ing 66 Captain Cook Lane Centerville ......................-.......................................................................... .........--••-------.......-----------••---•-•------•...--•-•-----•----- -.............. Owner Address W Kevin Hickey 72_ Carriage..1,dan------Ba xutable.-----•--.... Installer Address Type of Building Size Lot•-----•-_____--------------Sq. feet Dwelling—No. of Bedrooms.........3................................Expansion Attic (Zo) Garbage Grinder (no) Other—Type of Building ......cape __ No. of persons.......2.................. Showers ( 2) — Cafeteria ( no Pa Other fixtures -•------------------------------------•••-•-•-•••. Design Flow......... - 10 gallons per person per day. Total daily flow........330...........................gallons. W WSeptic Tank—Liquid capacity--.100 llons Length-------_------- Width................ Diameter.-----.......... Depth................ x Disposal Trench—No...................... Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No--------------------- Diameter.................... Depth below inlet.................... Total leaching area..................sq. ft. Z Other Distribution box ( ) Dosing tan f ) '-' Percolation Test Results Performed b K.At...2st _ .......................... Date..�__P2 3 _7�_ Y Test Pit No. 1..--.2-_-.____minutes per inch Depth of it.-._-12_........ Depth to ground water.-.4 min_..--. Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ ................................. Description of Soil ----..------------------••---------..........-•-••-----•-•----•---._......_....-- O 0'-2.5' loam subsoil -----•---•--••......•---•.. .............•--•----•-•••-•----••------••-••--•-•-•••••-----•-._...-•--•••••••--•-••-••--••--------•-•-.... v ........................................................ 2-'-5!•--•-.12........clean...medium...sand.......................................................... W x ------------------------------------------------------------------- ••--•---•---•-••••--•-••-•--••••---••-•--•••......------••-•-----•••------•-••••••--•-•••-•--•••--•--•-••---••............-•-----•-- U Nature of Repairs or Alterations—Answer when applicable-_-___•........................................................................................ Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of T IT LE 5 of the State Sanitary Code— The undersigned further agrees not.to place the system in operation until a Certificate of Compliance has been issued by the board of health. Si ---- ...................... Date Date Application PP lication Approved BY 1�� - r Application Disapproved for the following reasons:.................................................................. -_.___ -•----•---•........................•-----•--•--------------...--------------------------...........---------•-•••--••••-•--•-----•----------------•------------•---------•----------•••••-•----•--._.... Date PermitNo....................................... Issued....................................................... Date THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH ...........Town..................OF......Barnstable THIS IS TO CERTIFY, That the Individual Sewage Disposal System constructed (K ) or Repaired ( ) by....................................................Ejayin...Hi.chay.......--------------------•----••--•-•-------------------...............---•--.........-----.........--....• Installer at Lot #... 6...Dee......rf d O ermillp. has been installed in accordance with the provisions of T ` of The State Sanitary Code as described in the application for Disposal Works Construction Permit No.• .��_.•................ dated---/-�t-/-7-.7-?------------------ THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUE® AS A GUARANTEE THAT THE SYSTEM WILL FUNCTION SATISFACTORY. DATE................................................................................ Inspector.................................................................................... No.._._....- - -•- THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH Town._.. ....................OF......... arns.table.....................................:.------ App iratinn for Bh4paiia1 Works Tomitrnrtion Vamit Application is hereby made for a Permit to Construct (K ) or Repair ( ) an Individual Sewage Disposal System at: Lot # 56 Deerfield Road Osterville ---•-•-•..................................••---•-•-----•-----...................---•--•---•-..... .......---••---•--.....---•-••--------....----••••----.............---------•-----•-•••----....... Robert F. oc i -Address o Lc•t No. te��in 66 Captain Cook Lane Centerville ---------------------------•-----•--..........._.. r....--------•---...-----•------•----••---• ..........-----------------••--••-•-.........--------................ -............ Owner Address a Kevin Hickey 72-_Carriage..da.�.....I arnat able............. Installer Address d Type of Building Size Lot............................Sq. feet Dwelling—No. of Bedrooms._....._3.................................Expansion Attic {tO) Garbage Grinder (rig Other—T e of Building ease No. of persons.......2.................. Showers — Cafeteria n 114 Other fixtures ................. ......... Design Flow........ I 110.............gallons per person per day. Total daily flow--_____330.._............._......._...gallons. W .. , WSeptic Tank—Liquic capacity.....00- allons Length................ Width................ Diameter_----___--_--_ Depth................ x Disposal Trench—No. ..... .............. Width.................... Total Length.................... Total leaching area..........---------sq. ft. Seepage Pit No.............::...... Diameter.................... Depth below inlet.................... Total leaching area..................sq. ft. Other Distribution box ( ) Dosing tan ) '^ _ � Z Percolation Test Results Performed by -`"---- G�h.____����t, i .................... Date.......................__.__._......... mifiutes per inch Depth of estj, t: ............ Depth to ground water...4...min' Test Pit No. 1..... .......:.' Test Pit No. 2................minutes per inch .Depth of Test Pit.................... Depth to ground water........................ •---•----- ---- -------------------------- O (7'-2.5i loam....... , , -----• ............ ------- ------- ---- -- ------------------------------ --------------- ------------- _--------------------•-----........._........•-•....._.----2 5_'-• "---3-20-----.clean._ ig dium_sand_.. W .......................... UNature of Repairs or Alterations—Answer when applicable...............:................................................................................. --------•-----------------•--------•-•------------------•--•-----------------------.._..._..........-•--•-•.......--=------•-----••-•--•••••-••••--------••------•-•--••-•••-••........................ u Agreement The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Sanitary Code,,, The undersigned further agrees not to place the system in operation until a Certificate of Compliance has been issued by the board of health. Signed�................. ...........•--................................. .... - ••-•--•-•---Date-------------------- i J 1 f11 . Application Approved By..... ! ,�.�_��!?= fe'-l� h_�___ 7-- 74 41 Date Application Disapproved for the following reasons:-----•-•---------------•----•--•-----------------------•---...--------------•--•----------.........-•-•--------. r. Date PermitNo......................................................... Issued-....................................................... Date THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH Town Barnstable ...............................o F......... . . . .......... .................. Trrtifiratr of Tomplianrr THIS IS TO CERTIFY, That the Individual Sewage Disposal oh constructed ) or Repaired ( ) by-------•---------•-------------- Kevin Hickd'r------•--. .................. --•. . .....----•-•. ------•......................•----•-•••--------------- Installer at Lot__#---56-Deerf Deer -Road----Osterville----------- ._..... has been installed in accordance with the provisions of T r of The State Sanitary Code as described in the T -•---•• dated__At__' 7' application for Disposal Works Construction Permit �o...: __.__.. %^�"_...__._.._. � .................. THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GUARANTEE THAT THE; SYSTEM WILL FUNCTION SATISFACTORY. DATE........ :::.... .........:........................................_...... InSpector......................_...................................................-----_-•--= THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH Town Barnstable .............................OF......................................................... �- No.......s r�_........ FEE......................... Kn�Hi ckey Permissionis hereby granted.............................................................................................................................................. to Construct (XLo�r V4 aneerf 1nedivTV.Sae �ageDDitsposy�,Syjt� atNo...................................................................ivi Street 77 _�9 y as shown on the application for Disposal Works Construction Permit-'No.._..j_'/_`_ . Dated..__1-17....../.................. Ln� ---( ------- .........-- - Board of Health FORM 1255 HOBBS & WARREN. INC.. PUBLISHERS ` 9 . 3 2 5 o 7- 3 I oo - ,� Ago o6. 2G . Z D % s, TEST POLE k Z,0,/2, q - ' 9 PEe TO r2EeO,E'DS TO LJ/V TE R ! S A L I7 S L_ E //vSP M.IN//I-IU/"I OUILDIh(6 5ET3f3CK r2E0U/ �'- Ei"7ENT5 rCi2OA/7T rJ' S /DE J0 . Urel vEl, "qY I/ O7- 7-0 3E L©CAT ED P� Gr� O SED az' DR0 ©/NIS .3 OVE)e SE 4./E ,2 UNLESS DESIGti' FL.OI. l 0362 G1---�L1D�3y P-20 DES / GA.1 USED . peppaSED LEHC.f-i 200 SEP7-IL? 5H1191- - C O N F O R M T O C O L T/ O/�! TES T CODE y D ,97"ED .TULy 1, /977 �/t/D TOL�/it/ OF �'ESULTS C SILL: cLEV. TO 3E FT 1480VE )eD_ TOP OF T yp / c � jL PR. 0 / I L E2eyo F-O UNDATIO _,ti CT'E'f�DE fi'EiOVE LF',9C,%-f` /oo � . NO SCE L E �IeEA r%lAn/HoLE eovER To ExTErVD To //`'/t EreVJDuS COVER �VI7-H/h1 /` OF FIA/ISNED G)eRDE F /^JF/L7-,e/97/A/G N/IAIIN1UM /O'M/N/MUM 57-0AJE � " OF /""7-OZ 1 /0 f ✓ 24'1COVE,QS D/ST. S I —� �n0 VE,E' 1'✓AS1-/E D -5 TD,VE. " BOX CASTzT y 6'M/N. �c�c 2^yltiJ. 4 t'}JH WRYER O y D t3� L AJ M � . _ T,GHr 4 D/�_ /C7ON /A/- P,7 CH z--Ja"MAI. /¢„ � y4.,/rooT z Mrs/ P,`�h' � /LcJ � 4 -/ Z FOOT c G, LLON ewHsHC� Y /t*7 D t7YN I rr�v eT L 3 y STONE r6 LEf�CIH GRLLON 1,Vt�E 27 P/ T ` Ceec� f,L � /Al VERY C,q p P(2 /TY � �� j � �' ! R>e o UAJ D 5EpT/C Tf7NK IA/VE,e7- /A/ VE,eT l �r C x - /NVERT GA,e8F1GE GRINDE)e �,� / � , /: � t PLO T PL iq/`J �.r�t�� ;;4.A,� •so. a fl �- G>e�� U�,�� k/FI 7-E 2 ��:= �.. 6Cr94- E • / = 3D' DATE: llg�175 ' t• 8 E /I-IG LOT" "51 S S/-H O WN 1' r< ; O,A-/ fJ PL A/t/ R E C (D Z) E D /N 7TPE 8/9RIV- AL : ,�' TAL3LE COCiNTy eEG /Sr,ey O DEF_ DS ,,4* AC FCO,e _ Q SEPT/ C 7-.41`/K -ro BE FJ 1-1JAj- S Q Y' L D Gt I y C C7. T/ O A-1 .q n/D L. E/n4 C 9 L E� c P /J� G ram/ T S -7-073 A !v1l r1/- .7 ,vi C1 CJ 7 i c� f/'mil (J J"I O ©;;::>ET'?Ty z C E R 7- I F y Tra�? Th t�` I _ � l ,~. ;- L J /v s r-� N D S E P-TI e 7-14a S h o w AJ o A/ T /S P h f 15 C� ;r ,/ ' 2 O' Ff le 0/'7 F o U Al D P I `J OAj QN T"-'E G P O UICJ D /9S5 5J-40WN PE,2EON n� D 7`,f--//') 7- / 7" G��E",S C O N F•O,e,,A-1 DATE T i -I E 7-o T H 4E 8 U/ ,4., Z> I NG S E 7- 23 (2 AK RE Q v J;e E- M F A/7-5 0 F- 7-HE T"O J- ,A.r 0F /� T /y P �wK aR�X �✓ tYAi f.. —+l✓�'�7anr`-- 0! �� -b.+ ,G .r.a t.../ V 16E7YO,2 1,9 G N7