Town of Barnstable
' . Board of Health
I witisrAim •
MASS. 200 Main Street, Hyannis MA 02601
ass.
Office: 508-862-4644 John Norman,Chaimnan
FAX: 508-790-6304 Donald A.Guadagnoli,M.D.
F.P.(Thomas)Lee,P.E.
Daniel Luczkow,M.D.Alt,
March 4, 2022
Mr. John O'Dea
Sullivan Engineering
711 Main Street
Osterville, MA 02655
REr: 299,Eel River,Road;`Qsterville�� „sk
Dear Mr. O'Dea,
You are granted a variance, on behalf of your client. Hard-A-Lee LLC, to construct an onsite
sewage disposal system at 299 Eel River Road, Osterville.
The following variance was granted:
Section 360-1 of the Town of Barnstable Code::. To install a soil absorption
system and reserve area less than 100 feet away from a coastal bank.
This variance is granted because the physical constraints at the site severely restrict the
location of the septic system components due to wetlands in the area.
Sincerely
/IIhn Norman
Chairman
Q:\WPFILES\Odea 299 Eel River Road Septic Variance Sept 2021.docx
DATE: (( O L
$95.00 FEF*:
t Mom" Town of Barnstable . REC.BY
i479- a� '
Board of Health
3CI•>ED.DATE
- 200 Main Street,Hyannis MA 02601
Office: 508-8624644
(�C.l /l.r �✓ John T.Norman
FAX: 508-790-6304 (� Donald A.Guadagnoli,M.D.
Paul J.Cannifl;D.M.D.
F.P.(Thomas)Lee,Alternate
VARIANCE REQUEST FORM
LOCATION ��1I tNNa. (/� 114
•Property Address: G �
Assessor's Map and Parcel Number. �1" ) Size of Lot:
Wetlands Within 300 Ft. Business Name:
Subdivision Name:
APPLICANT'S NAME: Phone
Did the owner of the property authorize you to represent him or her? Yes _y No
PROPERTY OWNER'S NAME CONTACT PERSON
Name: IT(A.Y "L �� , L 1, Name: . rw\ '
pp, p p1xi -h n j lrc.
O
Address: U Ee- I �1kf' 2d a nJ1 Address: ga[n '�7t , 05 jt nj
Phone: Phone: hb 1
EMAIL: to C
VARIANCE FROM REGULATION(Incl.Reg.Code a) REASON FOR V RIANCE(May attach sep sheet if more space needed)
iy(J, - (D 6, occ, aioousci srah(.sysk(m As, I ura+(&..
NATURE OF WORK: House Addition U House Renovation LJ Repair of Failed Septic System
Checkllsl (to be completed by office staff-person-person receiving variance request application) -
Please submit first four on list as S collated packets.
✓A. Five(5)copies of the completed variance request form
B. Five(5)copies of MA DEP approval letters for Innovative/Altemative septic system(when proposing an UA system or
secondary treatment unit(S.T.U.).
✓C. Five(5)hard copies of engineered plan submitted(e.g.septic system plans)and one(I)electronic version submitted to email:
health(atown.bamstable.ma.us *(Pool Plan—5 hard copies)
Y6.Five(5)copies of labeled dimensional floor plans submitted(e.g.house plans or restaurant kitchen plans)and one(1)electronic
version.
_✓ A completed seven(7)page checklist confirming review of engineered septic system plan by submitting engineer or R.S.
Signed letter stating that the property or business owner authorized you to represent him/her for this request
Applicant must notify abutters by certified mail at least ten days prior to meeting date at applicant's expense(for Title V and/or
local sewage regulation variances only).
Full menu—Five(5)copies of full menu submitted(for grease trap variance requests only
Fee Submitted*$95.00 for the following variances: 1)New construction, 2) Septic repairs with increase in flows, and 3)New
owner/new lessee applying for food, pool or body art variances. Exemptions from Variance Fee: 1) Septic repair withou an
increase in flow and variances granted at the counter,2)Monitoring Plans,and 3)Temporary Food(not a"variance").
Variance request submitted at least 15 days prior to meeting date
VARIANCE APPROVED John T.Norman
NOT APPROVED Donald A.Guadagnoli,M.D.
REASON FOR DISAPPROVAL Paul J.Cannift;D.M.D.
Q:\Application Forms\VARIREQ Rev Jan 1-2020.docx m
t
MAIL-IN REQUESTS
Please mail the variance fee amount of $95.00 (if applicable), along with the documents listed
below; to the following address: Checks payable to: Town of Barnstable.
Town of Barnstable
Public Health Division
200 Main Street
Hyannis, MA 026.01
For septic system variance requests, each of five packets must include:
1) Variance Request Form,
2) Letter for the Board with further information on the reason for the septic
variance request (Optional),
3) MA DEP Approval letters for proposed Innovative Alternative (I/A) septic
system or a proposed secondary treatment unit (S.T.U.)
4) Engineering plans,
5) Floor plans.
In additional to the five septic packets above, include one copy of the seven (7) page checklist,
the authorization letter, copy of abutters notice, and fee, if applicable (see checklist below).
Please send one electronic submission using a PDF or .jpg of the engineering plan and floor
plans to email: healtha-town.barnstable.ma.us. (Total email must be less than 10 megabytes.)
For grease trap variance requests, each of five packets must also include a full menu. (see
checklist-below).
Checklist - Please submit first four on list as 5 collated packets.
A. Five(5)copies of the completed variance request form
D. Five(5)copies of MA DEP approval letters for Innovative Alternative septic system(when proposing an I/A or
secondary treatment unit(S.T.U.).
C. Five(5)hard copies of engineered plan submitted(e.g. septic system plans)and one(1)electronic version submitted
to email: health a barn stable.ma.us
D. Five(5)copies of labeled dimensional floor plans submitted(e.g. house plans or restaurant kitchen plans)and
one(1)electronic version submitted to email: health@town.barnstable.ma.us
A completed seven (7) page checklist, confirming all required items are on the engineered septic system plan
submitted by engineer or registered sanitarian.
Signed letter stating that the property or business owner authorized you to represent him/her for this request
Applicant must notify the abutters by certified mail at least ten days prior to meeting date at applicant's expense(for
Title V and/or local sewage regulation variances only).
Full menu—Five(5)copies of full menu submitted(for grease trap variance requests only)
Fee Submitted *$95.00 for the following variances: 1)New construction,2)Septic repairs with increase in flows,3)
New owner/new lessee applying for food, pool or body art variances. Exemptions from Variance Fee: 1) Septic
repair without an increase in flow and variances granted at the counter. 2) Monitoring Plans, and 3) Temporary
Food(this is not a variance).
Variance request submitted at least 15 days prior to meeting date.
For further assistance on any item above, call (508) 862-4644
Email: healthO-town.barnstable.ma.us
Back to Main Public Health Division Page
NARRATIVE TO ACCOMPANY
SEPTIC VARIANCE REQUEST
For
Hard A Lee LLC
299 Eel River Road, Osterville '
Map 115 Parcel 003
The project site is located at 299 Eel River Road in Osterville. The property is a l+ acre
parcel of land divided in 1967 and purchased by die current family owners in 1977. '
Septic permits were previously granted but not constructed for similar.septic systems on
dhis site in 2002, 2014, and renewed 2017.
In 2014 FEMA updated die 100 year Flood Zone Maps for die Town of Barnstable and
raised die dieoretical 100 year flood elevation from 11 (NGVD) to 12 (NAVD). Following die
topography of die landform, this increase in die dieoretical flood elevation shifted die limit of
Conservation jurisdiction 10 - 15' landward towards Eel River Road.
A new Order of Conditions for proposed development of a single-family dwelling was
issued by die Town of Barnstable Conservation Commission in June 2020. -The approval was
appealed to die Department of Environmental Protection by abutters, and a Superseding Order of
Conditions was issued by die Department in March 2021 Affirming die approval.
Due to die landward shift of Conservation jurisdiction resulting from die dieoretical 100
year flood mapping, a variance from Town of Barnstable Board of Healdi Regulation 360-1 (100'
setback) is now required for die system.
Tlhis State Defined Coastal Bank is non-eroding, not seaward facing, and not immediately
landward of anodier coastal wedand. The proposed SAS requires no State variances, is located
approximately 250' from die Town Defined Coastal Bank/actual shoreline, and more than
adequately protects die public healdh, safety,welfare, and the environment.
Garage
Kitchen
i
First Floor
Living Room Dining Room
�,2
Bedroom �o
1 �h
� a~p
o�h p,�
BO
0
�h
°Cr
Q",
�° Floor Pions
V- Hord E Lee LLC
gyp° 299 Eel River Rood
1"=20',
pocuSign Envelope ID:631 DA1 BE-D252-42A4-96F6-78A06ADA05D0
September 8, 2021
Town of Barnstable
200 Main Street.
Hyannis, MA 02601
RE: 299 Eel River Road,Osterville
Dear Ladies and Gentlemen:
Please accept this letter as authorization to have a representative from Sullivan Engineering&Consulting,
Inc.represent Hard-A-Lee,LLC,at the property 299 Eel River Road,Osterville,on matters before the
Town of Barnstable related to designing,improving,modifying,upgrading,replacing and or unstallinng
betterments to property we own at 299 Eel River Road. '
We trust this meets your needs.
Thank you,
DocuSigned by:
08E699757DB7479...
a
TRANS. NO.:
CITY/TOWN: er�,'l�e
APPLICANT: }}
ADDRESS: 7—
DESIGN FLOW: '5— B/ < 7 W G P 7 ' gpd
REVIEWED BY: Ro DATE: S ZyLa2�
N/A OK NO
GENERAL
Legal boundaries denoted,[310 CMR 15.220(4)(a)] �—
Street, Lot, tax parcel number and lot number noted on plan [310
CMR 15.220(4)(u)]
Locus Provided [310 CMR 15.2204(t)]
Plan proper scale? (1"=40' for plot plans, 1"=20' or fewer for l%
components) [310 CMR 15.220(4)] -
Easements shown [310 CMR 15.220(4)(b)] ✓
System located totally on lot served [310 CMR 15.405(l)(a) for
upgrades]- if not, a variance is required [310 CMR 15.412(4)]
Location of impervious surfaces (driveways, parking areas etc.) lam`
[310 CMR 15.220(4)(d)]
Location all buildings existing and proposed 310 CMR �=
15.220(4)(c)]
Location and dimensions of system components and reserve "
areas. [310 CMR 15.220(4)(e)]System Calculations [310 CMR 15.220(4)( ]
daily flow
septic tank capacity (required and provided) v—
soil absorption system (required andprovided)
whether system designed for garbage grindei
North arrow [310 CMR 15.220(4)( )] c/
Existing and ro osed contours 310 CMR 15.220(4)( ] -
Location and log of deep observation holes (existing grade el. on
each test) [310 CMR 15.220(4)(h)]
Names of soil evaluator and BOH representative j310 CMR
15.220(4)(h) and (i)]
Location and date of percolation tests (performed at proper -
elevation?) [310 CMR 15.220(4)(i)]
Percolation test results match loading rate? [310 CMR 15.242]
Certification statement by Soil Evaluator [310 CMR 15.220(4)0)] -
Observed and Adjusted groundwater(method for adjustment
given or indicated) [310 CMR 15.103(3) and 310 CMR
15.220(4)(n)] a
Address .�`l �e�' �ir Sheet 1 of 7
r
N/A OK NO
Location of every water supply,public and private, [310 CMR
15.220(4)(k)
within 400 feet of the proposed system location in the case
of surface water supplies and gravel packed public water supply
within 250 feet of the proposed system location in the case
within 150 feet of the proposed system location in the case t/
of private water supply wells
Location of all surface waters and wetlands located up to 100 ft.
beyond setbacks listed in 310 CMR 15.211 and any catch basins
located within 50 ft. 310 CMR 15.220(4)(1
Water lines and other subsurface utilities located [310 CMR
15.220(4)(m)] (if water line cross see 310 CMR 15.211(1)[1])
Profile of system showing invert elevations of all system
components and the bottom of the SAS [310 CMR 15.220(4)(o)]
Stamp of designer 310 CMR 15.220(1) and 310 CMR 15.220(2)]
Stamp of Registered Land Surveyor(required if construction
activities within 5 ft. of lot line) [310 CMR 15.220(3)]
Test Holes adequate (two in each of the primary and reserve
unless trenches as permitted in 310 CMR 15.102(2) or as
approved for an upgrade under LUA at 310 CMR 15.405(1)(k)]
Test hole adequate to demonstrate four feet of suitable material?
310 CMR 15.103(4
Test Holes adequate to confirm adequate groundwater separation?
310 CMR 15.103(3)]
Benchmark within 50-75' of system [310 CMR 15.220(4)(q)]
Materials specifications noted? [various sections of 310 CMR
15.000]
System components not> 36" deep (unless Local Upgrade
.Approvalor LUA requested) [310 CMR 15.405(1(b)]
Address Z9� eL Q 1)<e-r I&aj Sheet 2 of 7
N/A OK NO
SEPTIC TANK
Size OK? 310 CMR 15.223(1
Inlet tee located ten inches below flow line [310 CMR 15.227(6)] v-
Outlet tee 14" or 14" + 5" per foot for increase ft depth [310 CMR
15.227(6)]
Outlet tee with gas baffle or approved filter [310 CMR 15.227(4)]
Note regarding installation on stable compacted base [310 CMR
15.228(1)
Separation between inlet and outlet tees (no less than liquid
depth) [310 CMR 15.227(2)]
Inlet/Outlet elevations at least 12" above high groundwater
(except as described 310 CMR 15.227(5)) or permitted for
upgrades under LUA [310 CMR 15.405(1)(k)]
Minimum cover 9" (Tanks buried more than 9" must have risers
on all openings and on the d-box) [310 CMR 15.2228(1) and 310
CMR 15.232(3)(f)] _
Three access covers (inlet and outlet must be 20" or greater) - l�
middle access at least 8" (by 7/07) [310 CMR 15.228(2)]
Access to within 6 " of grade - one port for systems<I 000gpd,
two for systems>1000 gpd [310 CMR 15.228(2)]
All at-grade covers secured to unauthorized access? [310 CMR �-
15.228(2)]
> 10 ft from building foundation [310 CMR 15.211(1)] t�
Buoyancy calculation Required/Done [310 CMR 15.221(8)]
H-20 Where appropriate? [310 CMR 15.226(3)] • A/t 11,2
Setbacks from resources [310 CMR 15.211]
Multi-Compartment Tanks
Required when other than single-family dwelling or flow>1000
d [3 10 CMR 15.223(1)( )J11 b
'gyp
First compartment 200% daily flow; Second compartment 100%
daily flow [310 CMR 15.224(2) and (3)]
"U" pipe through or over baffle, outlet of each compartment with
gas baffle or approved filter [310 CMR 15.224(4)]
F
Address E7C ej'(1er O" Sheet 3 of 7
N/A OK NO
BUILDING SEWER AND OTHER PIPING
Located at least ten feet from any water line? [310 CMR
15.222(2)]
Disposal piping at least 18" below water line (when water and
sewer cross, see 310 CMR 15.211(1)[1])
Cleanouts required/provided ? [310 CMR 15.222(8)]
Thrust blocks specified in force mains? 310 CMR 15.221(6)(c)] 1�
Slope of sewer line not less than 0.01 (1/8"/ft) 0.02 preferable
310 CMR 15.222(6
Proper pitch on all runs? (.005 within gravity-distributed trenches v.
and beds) [310 CMR 15.251(9) and 310 CMR 15.252(2)(c)]
Siphon problem/(leachfield below pump chamber)
Endca s or vent manifoldspecified?
Size and orientation of discharge holes specified? (not smaller
than 3/8" not larger than 5/8") [310 CMR 15.251(8) and 310
CMR 15.252(2)(h)]
Materials specified (310 CMR 15.251(5) specifies various pipe
types allowed)
DISTRIBUTION BOX
Stable compacted base [310 CMR 15.221(2) and 310 CMR
15.232(2)(a
Splash plate or baffle tee required on inlet/provided? (when
pressure sewer to d-box or steep pitch of gravity sewer) [310
CMR 15.323(3)(a)]
Riser if deeper than 9" [310 CMR 15.232(3)(f)] ri—
Inside minimum dimension 12" [310 CMR 15.232(2)(b)]
Minimum sump 6" [310 CMR15.232(3)(e)]
Watertight cover if<2000gpd); waterproof manhole if>2000gpd �-
[310 CMR 15.232(3)(d)
PUMP CHAMBERS
Capacity (emergency storage above working--design flow)? [310 /, /
CMR 231(2)] l
Proper setbacks [310 CMR 15.211 (same as septic tanks)]
Watertight 20-in minium access manhole at least 20" MUST BE
TO GRADE [310 CMR 15.231(5)]
Service components accessible (not too deep with piping,
disconnects accessible)
Alarm floats - alarm on circuit separate from pumps specified?
Exceeds two units must have two pumps operating in lead-lag
mode. [310 CMR 15.231(6) and(8)]
Stable Compacted Base 310 CMR 15.221(2)]
Buoyancy calculationsneeded ? Provided? 310 CMR 15.221(8)]
Address 2"l "l re(/ f, L-el peaQ d Sheet 4 of 7
N/A OK NO
SOIL ABSORPTION SYSTEMS (SAS) GENERAL
Calculations correct?
4 feet of naturally occurring material demonstrated? [310 CMR
15.240(1)]
Required separation to groundwater? [310 CMR 15.212)]
Aggregate specified as double washed [310 CMR 15.247(2)]
System Venting re quired/provided? (system under driveway or r/
>36" deep) 310 CMR 15.241]
Inspection ports specified and within 3"final grade? [310 CMR
15.240(13)
Breakout requirements met? (No violation of breakout elevation '
within 15 ft of SAS unless barrier) [310 CMR 15.211(1)[4] and
Guidance Document]
GALLERIES,PITS,CHAMBERS 310 CMR 15.253
Chambers and Gal. in trench configuration supplied with inlet �-
every 20 ft. [310 CMR 15.253(6)]
Each structure with one inspection manhole (if>2000 gpd must
be to grade) [310 CMR 15.253(2)]
Aggregate 1'minimum-4'maximum. [310 CMR 15.253(1)(b)] !/
2' sidewall credit maximum [310 CMR 15.253(1)(a)]
In bed configuration, inlet every 40 sq. ft. [310 CMR 15.253(6)]
TRENCHES 310 CMR 15.251
Width T minimum 3' maximum [310 CMR 15.251(1)(b)]
100 feet -maximum length 310 CMR 15.251(1)(a)
Minimum separation 2x effective depth or width whichever
greater(3x if reserve between trenches) [310 CMR 251(1)(d)]
Situated along contours [310 CMR 15.251(2)]
Breakout OK? [310 CMR 15.211(1)[4] and Guidance Document]
BED SAS (Maximum size of bed or field 5000 gpd)
minimum 2 distribution lines [310 CMR 15.252(2)(a)]
Maximum separation between lines 6' [310 CM R15.252(2)(d)]
Maximum separation between lines and outside of bed 4' [310
CMR 15.252(2)(e)]
Aggregate depth below discharge pipes 6" minimum, 12
maximum. [310 CMR 15.252(2)(g)]
Separation between beds 10'minimum. [310 CMR 15.252(2)(f)]
Bottom area used in calculations only [310 CMR 15.252(2)(i)]
. t
p�
Address l l ( �i U ; Sheet 5 of 7,
N/A OK NO
DID THE PLAN INVOLVE
Pressure Dosed System ? Provided pump and piping
calculations as required [310 CMR 15.220(4)(r)]
Pressure dosing required on all systems >2000gpd or alternative
systems under remedial approval [310 CMR 15.254(2) and I/A
Remedial Use Approvals]
If used in gavelless system - make sure jet is directed as not to
scour soil interface [Guidance Document
Inspections once per year(systems< 2000 gpd) or quarterly
>2000 dgood to note on plan 310 CMR 15.254(2)(d)]
Construction in fill - Did the plan specify that the fill shall meet L�
the specification of 310 CMR 15.255(3)?
Impervious barrier and/or retaining wall ? [Guidance Document] t/
Impervious barrier installation must be supervised by
designer [310 CMR 15.255(2)(b)]
Retaining wall must be designed by Registered Professional
Engineer 310 CMR 15.255(2)(a)]
Side slope not exceed 3:1 ? [310 CMR 15.255(2)]
Breakout requirements met? [310 CMR 15.252(2) and
Guidance Document]
At least 5 ft. from impervious barrier to edge of SAS (10 ft. t/
recommended) 310 CMR 15.255 (2)(e)]
Gravelless System[IIA Approval Letters]
Check DEP Approval letters for credits and design conditions
If used with pressure dosing do not allow pressure discharge
to scour soil interface
Alternative Septic System[I/A Approval Letters]
Was DEP Approval Letter provided and/or have you
reviewed the letter for conditions? r
Is the technology being properly applied and does it meet all
DEP Approval Conditions?
Is there a note on the plan regarding the requirement for
perpetual maintenance agreement?
Any alarms involved on separate circuits
Did the applicant submit an operation and maintenance
manual?
Has applicant submitted a copy of a maintenance
Variances
Are the variances listed on the plan ? [310 CMR 15.220
(4)( )]
RLS Stamp necessary on plan if a component is within five
feet of property line [310 CMR 15.412(4)]
New construction or increased flow proposed- [Refer to 310
CMR 15.414
Address Q lFe-� �,Uer 6,Qp1 Sheet 6 of 7
N/A OK NO
ti Nitrogen Sensitive Areas
Is the system in a Designated Nitrogen Sensitive Area(Zone II for
a public supply well)? [310 CMR 15.214, 310 CMR 15.215 and �.
310 CMR 15.216 - also refer to Policy regarding upgrades of such
existing systems]
Is the system proposed on the same lot as served by private well ?
[310 CMR 15.214(2)] - '
Are the nitrogen loads proposed in compliance? [310 CMR
15.216(1)]
Miscellaneous
Pumping to septic tank? [ 310 CMR 15.229] ✓ "
Shared System [310 CMR 15.290]
I
I
z
E
Address j ( fZ 1 P,'ver i&oj Sheet 7 of 7
p
Sull * Engineering &
Ivan Consulting, Inc.
(508)428-3344• P.O. Box 659, 711 Main Street, Osterville, MA 02655
seci@sullivanengin.com • www.sullivanengin.com
**** ABUTTER NOTIFICATION LETTER****
RE: Board of Health Public Hearing
As a direct abutter of a proposed project,please be advised that a Variance Request has been
filed with the Town of Barnstable Board of Health. The specific information is as follows:
Applicants: Hard-A-Lee, LLC ,
Project Location: 299 Eel River Road,Osterville
Map 115 Parcel 003
Proposed Project: Septic for proposed dwelling requiring a variance request from
Town of Barnstable 360.1 — Setback Requirement
The proposed septic system is located< 100' from the coastal
bank.
Applicant's Agent: Sullivan Engineering& Consulting, Inc.
7 Parker Road, P O Box 659
Osterville, MA 02655
phone: 508-428-3344
Public Hearing: Date: September 28, 2021
Time: 3:00 PM
Place: Barnstable Town Hall
367 Main Street
Hyannis, MA 02601
James H. Crocker Hearing Room, 2nd Floor
Plans and the application describing the proposed activity are on file at the Board of Health
office, 200 Main Street, Hyannis and at Sullivan Engineering & Consulting, Inc.'s office. Please
call if you have any questions regarding this notification.
Please call the Board of Health on the day of the Public Hearing to confirm the location and time
for the hearing.
is
l
r
DIRECTIONS:
Charcoal Filtered Vent From Hyannis - Take Route 28 into Osterville, At the
Final Location to be Determined lights by White Hen Pantry take a left onto Osterville
Proposed Finish Floor ` at time of installation or in West Barnstable Road and follow to the end, Take a left
DESIGN DATA Not to be used as accordance with Landscape Plan into Main Street; Take a right onto Parker Road; At
a Bench Mark the stop sign take a right onto West Bay Road, Take
Family
Single r� • '
g y F.F. D. 17.00 a left onto Eel River Road; Property is on the
-5 Bedroom @ 110 GPD * _ * 15' ri
F.G. EL. 13.5.E Final Foundation Grading To Be See Note 6 (typ.) 9 #
No Garbage Grinder F G. EL. 13.8 F.G. EL. 12-13.8 Min. fr � � � � •
Total Daily Flow=550 GPD F.G. EL. 14.0
Coordinated With Landscape Plan
a.
Use a 1500 Gal Septic Tank ( Complies
3.75' w
Flow E uilizers �1, With FLOOD ZONE: fiY ;
LEACHING AREA Finish Grade
q Breakout
As Required E Zone A13 & C zk ' �
550 GPD/0.74 TAR =743.2 SF Required EL. 12.25
' Installer To $ Community one No:
Sidewall2(42'+12.83)2'=219.3 SF EL 11.11 1500 Gallon 3' Max. 250001 0016 D
Confirm Prior EE • �__ � #
Bottom Area 42x12.83=538.9SF To Any Work Septic Tank EL. 10.86 z Top EL. 10.80 9" Min Compacted Fill Filter July 2, 1992
Total Provided=219.3+538.9=758.2 SF(561.1 GPD) H-20 Required EL. 11.4 D-Box r Y
See Note 5 H-20 EL. 10.25 � s • w '�
( ) Fabric
t ID
LEACHING CHAMBER DESIGN 2„ 1/8 nd 112 ..
9.80 Leaching
All Pipes to be Schedule 40. Use Chamber Pea Stone
ZONE: � w
4-500 Gallon Leaching Chambers in a To Be Installed On H-20 3' 3/4" - 1 l/2" RF-1
Stable ompac a ase Bot. EL. 7.80 H-20
Double Washed Stone Field as Shown. LEACHING Double Washed
10' Bedding,"T"s, Stone Area (min.) 87,120 SF LOCATION MAP
9 CHAMBER
Fronts a (min) 20' (1"-2000f)
::. :::::. .. .. ::. .. ......
Min. Inspection Port, If.�rcb mere Rei iQwe.8c: Replace . Width min) 125'
& Boffels All UnsU,tdble Sbals Witkiitl : o co Setbacks:
r 4' - 10"
as Per Title 5 uter..PerimEfer....... The Sysf4F I Front 30'
10' Min. - Slab ......
12' 10" ----I Side 15' ASSESSORS REF.:
20' Min. - Foundation EL. 2.2' Rear 15' Map 115, Parcel 003
Groundwater Elevation CROSS SECTION OF CHAMBER
SEPTIC NOTES �' Per Test Hole 3
1.Location of Utilities Shown on This Plan Are Approx.At Least 72 Hours DEVELOPED PROFILE OF SYSTEM �+�+ �+ o yERL/`1 1 DISTRICT.
Prior to Any Excavation For This Project the Contractor Shall Make NOT TO SCALE REFERENCES:
the Required Notification to Dig Safe(1-888-344-7233). T �+
2.The Contractor is Required to Secure Appropriate Permits From Town NOT 1'O �7CALE AP - Aquifer Protection District
Deed C192264 As Shown on Plan Entitled
"Revised Groundwater Protection
Agencies For Construction Defined by This Plan.
Plan# 2664-93 Overlay Districts" - April, 1993
3.Wherever Sewer Lines Must Cross Water Supply Lines Both Lines Shall
Be Constructed of Class 150 Pressure Pipe and Shall be Water Tested to
Assure Watertightness. In General,Water Lines Shall be Constructed in
Coordination With COMM Water,and Shall be in Accordance
With 248 CMR 1.00-7.00&310 CMR 15.00. GENERAL NOTES:
4.A Minimum of 9"of Cover is Required for All Components. , 1.) Pool Disinfectant to be ozone
5.All Structures Buried Three Feet or More or Subject i' or approved equal.
to Vehicular Traffic to be H-20 Loading.It is the Engineer's €` N/F 2.) Roof & Patio Runoff Directed to
Recommendation that H-20 Always be Used. # 271 Drywells.
6.Install Watertight Risers and Covers to Within 6"of Finished Grade
Simons, Pamela Ellis TR ET AL
Over Septic Tank Inlet and Risers to Grade over Septic Tank Outlet,
D-Box,and One Leaching Chamber. DEED C139231 LEGEND
7.Septic System to be Installed in Accordance With 310 CMR 15.00&
248 CMR 1.00-7.00 Latest Revision and the Town of Barnstable Existing En CI OaCh m en tS ® - _ _ �./ \ \ \
Board of Health Regulations. Existing Deck t0 Remoln -�"� i / / / JI 0 I / / W Uderground Water Line
8.All Piping to be Sch.40 PVC. Pier _ _ - / % ° \ O Rebar
9.D-Box Shall Have a Minimum Inside Dimension of 12",and a Minimum _ '` -. / / \ ' 1 \ / TP-t
Sump of 6"• _ __ _ - _ _ _ '- + ! 2176.651 \ 0 Test Pit
10.The Separation Distance Between the Septic Tank Inlets and / - _- 41:00' _._ -tirtg-1N - -� `Ex'i3ting Drive _ "� _ / ( N68' I41' 3 "W + �' DN / 0 CB/DH � Deciduous Tree
Outlets Shall be No Less than the Liquid Depth.Inlet Tees Shall Extend - - I _ - ' i
� � ( '/ __. -. _ 7 � l / � ,\•.� �.. __ , 6 � � Utility Pole
a Minimum of 10"Below the Flow Line.Outlet Tees Shall Extend 14" J
i ( / _ _ C �_��- �` f / r o / ( / 100' / OHW- Overhead Wires
Below the Flow Line,and Shall be Equipped With a Gas Baffle. ( ! - - 25- -
/ 1 l Elevation Contour
J ( 50' , f / _ Coniferous Tree
E Underground Utilities
I I N l l T . 9If
�J �� -- , ; �� ����'� � ��` A 50 636 S.F.
Land S b TO �yd2
6e�ta1 rm
+ • ( I (I If /l !l / // /1 I /� /�t l D Flowag�re, �, .- -- ..- -,s! /f� ,-.'•�` 3
/ -1
/ I
/ I
! Watqj ine _..,'
to be f leeved VARIANCES:
(
. I
N`f i , - - ° with r 50 PSI r I 1 r I l l § 360-1 TOE? Setback Requirement
Pres re Pie •
P I -
� /f ' f%/ -,,,• r ,,.. � � � / � �'� .✓' ......... r Septic Tank, D-flax r•ort,:.�i of 5A� and r,aerve
o
- \ location <100' from Coastal Bank
0o'
Approved Pier ( ( I ( \ \ /
SE3-5250 ( ( Q J / ) / ` / ! / o � f0- °/~ r / -�� 1 - - E-= - i ' / o
TH- l
f
/� PROPO�D
7; r#
( / ! 4."pAtN r ( ' I SWELLING J J l ' 3 1J9 1
\ ( F.F. ',EL. 17.0± I r3
o - H-24, Pr posed
0 1 v° / m J 1#, / 1 / r -9 t \ \ \ 150 G61ion
li J I J j�f .. , - `\ \ \ `',;• \. Sepis
PROP D I .. \ \\ A�O� _ PR coI
t I t I I 1 ! �•OL o -
r �o � � \ 4'S'�l�
/ ( ( � j I EL. 1�0± F t Vet I /, -I % Pro
� / --� F` �r co � -- \ �--- -,, ' ( I O D-Box
PERC TEST: 14,464 ., : --_. / Lerlc+ ubJect To _ 8 \ \ } / •
PERFORMED BY:PETER SULLIVAN PE- SULLIVAN ENGINEERING J /� J I ; . 'j `� ---= i 1 ( ( I
SOIL EVALUATOR NO.2376 l C�aStal Storm Flow \ \ \ Ocv 1;'
WITNESSED BY:DONNA MIORANDI,R.S. TOWN OF BARNSTABLE r ( I cv J ( J l j ' - f ( I l. " \ --
SEPTEMEER 17,2014 ( i J 'J l - - " S /� 33 15 / ~• -- ` _ � i I
l o f f / I S 'G aT 12.8 4-500 Gallon
SITE PASSED ! J J J J / / , , E \33.14 837, E 88.26 ,�5' j��` � ,( Chambers 0
JJI 1 il� r �� / / '25 Ss� S 73'47 50 _ / 8�,s, I 4.0
'0 4'�^ _D1�CB Fnd .� l 4' of Crushed Stone
TEST HOLE - I EL. 1a.o TEST HOLE - 2 EL.15.3 ! ( I III I / �3 \ _ , f
.:....... r
//' / / Bench Marty 0 I
.... .::::.: ... ......•
;. ( J// !l/ f✓ , r / /, Ef.-1204' 42.0 -I
l /
olzArrxc..: oRAt�I . ( ' ( / /// J / / . �`� N/F __ l
. ... . .
5 !::;. ::'::....: 13.6 3" 1 \�� 333
. . .
15.1
1
J J! , li / i \ / ti ,
..::::::: A ;�i ... 4 R.a/ ::.:' : ::: 1 �, , f 1 Birmingham, Karen M &. ovack nneth
I I, „I / l 1 SAS DETAIL VIEW
.: ':?. .. .... BYt(J1?VN...;;. :: ; BIt(7V11N ! D 4
.. ! ( J / / a DEED C1 09
l5".::>.:. LUAIvtY 5A1 ........... ... 12.7 21 OM'z:SANI)'.;. .:::.;:>.: 13.5 JJ // S 71'31 .80 E 1 i
B LAYER iOYR 5/6 B LAYER I OYR 5/6 ' NOT TO SCALE
YELLOWISH BROWN YELLOWISH BROWN �! J ' 1 1 t0 Record HW)
SAND SAND I Jf J, 105f ( s'
36" PERC TEST 10.8 38" PERC TEST 12.1 ' +� rC� C' /f� ' SITE PLAN
25 GALLONS IN 8 MIN. 25 GALLONS IN 8 MIN.
38" PERC RATE<2MINAN TAR=0.74 11.8 42" PERC RATE<2MINAN TAR=0.74 11.8
C LAYER 10YR 7/4 C LAYER IOYR 7/4
VERY PALE BROWN VERY PALE BROWN Scale 1 rr-20r
1 " COARSE SAND 4.0 120" COARSE SAND 5.3
NO GROUNDWATER ENCOUNTERED NO GROUNDWATER ENCOUNTERED �P�SIi OF MqS
20
J C.
A
t 1 ti
r 168
TEST HOLE - 3 EL.13.0 TEST HOLE - 4 EL.16.0 r
9o,��9F0/STE���,c� ;
. .... .. . .. ... . .......... ..
.: /OMAL ��
_ ..
........................................ ..
ORANTG."::.`: "..:: ORFsANIC....:.:
..... .. .. ........
g .•. •::.. ..:.:..........::.:::::::::::•:: 12.7 3" '..:........: ::::.:... .... ..... 15.7
A I AIR 3Xt:4L3 . .:. A AXB1i l4XR 4/3':::? ?::..:
81iOVUR`T:; ":'..........;: 13itOtiwN:: r
..
.........................................................
20":.:.:: .....O fY AN : :. : `:;;:.` 11.3 18" ... Z}AMY S�cN :: .::•: `'::'.:'? 14.5
B LAYER lOYR 5/6 B LAYER lOYR 5/6 Revision: Add Proposed Septic Design 91212021
YELLOWISH BROWN YELLOWISH BROWN Plan
al" SAND 9.6 36" SAND 13.o NOTES: PREPARED FOR: PREPARED BY. TITLE: Slte
C LAYER 10YR 7/4 C LAYER 1 OYR 7/4
VERY PALE BROWN VERY PALE BROWN • Engineering & Alternative Im rovements
130" COARSE SAND 2.2 132" COARSE SAND 5.0 on The topographic information shown was located
NO GROUNDWATER ENCOUNTERED NO GROUNDWATER ENCOUNTERED on the ground by conventional survey methods on or
HARD-A-LEE LLC p - M
between 01/JAN/14 and 24/FE8/14. U ivan consuitinonc. At `�3�� Ee' �IVer 1�Oad2.) The property line information shown hereon was O
compiled from available record information. (508)428-3344•P.O.Box 659.711 Main Street,Osterville,MA 02655 299 Eel Rivrlewr Road
�Sfervllle, MA 0�655 secl@suilivanengin.com•www.suilivanengin.com
level
The datum used is ark used
b fixed mean sea Mass.
level datum. The benchmark used is from oBamstabl a (Osterville)
satalite RTK provided by Applied Coastal Research & Draft: CTR Field: WMK CTR W
Engineering. 20 0 10 20 40 80 _
Review: JOD Comp.: CTR DATE: SCALE: CO
Project# 1998049 Pro ec t: Ellis December 18, 2020 •1 rr=20 r