HomeMy WebLinkAbout0148 ROBBINS STREET - Health M Robbins Street)
Osterville P
A = 142 105 u.
t
�. 4.
x
0
o - - - - ----- — --. _.
�4
�.AI
THE COMMONWEALTH OF MASSACHUSETTS `` Vie,
BOAR® OF HEALTH
r.
...........................................O F......................................
ApplirFation for Dispag ai Works Tonitrnrtion 11amit
Application is hereby made for a Permit to Construct ( or Repair ( ) an Individual Sewage Dispo
system at: .... f �
Location-Address �� or Lot No.
..• � �"°....
...................... •..... ........ ...... !!....a ........ .................°.%/
'�es•...•.........._.
rOwn d � �
" .. ......
Insller � Add
Type of Building Size Lot............................Sq. feet
U Dwelling A-: of Bedrooms _Expansion Attic ( ) Garbage Grinder ( )
`4 Other—T e of Building .. No. of persons............................ Showers — Cafeteria
Pa Other fixtures ----------------------------------------------•-•- .
W Design Flow............................................gallons per person per day. Total daily flow............................................gallons.
WSeptic Tank—Liquid capacity............gallons Length................ Width................ Diameter................ Depth................
x Disposal Trench—No. .................... Width..................... Total Length.................... Total leaching area....................sq. ft.
3 Seepage Pit No..-----•_--.--_-- -- Diameter.................... Depth below inlet.................... Total leaching area..................sq. ft.
Z Other Distribution box ( ) Dosing tank ( )
Percolation Test Results Performed by.......................................................................... Date........................................
aTest Pit No. 1................minutes per inch Depth of Test Pit.................... Depth to ground water---------...............
Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................
Description of Soil.__.__.._ .
`
W -------------------------------------------------------------------------------------................................. •. ----••.
U Nature Repairs Al rati s—Answer en applicable._. ___�___-����--- -------------------------------------------
or
--.--•••-•-•-••-- -- �--c.................•-------------------------------••-------------------------------------•-----........-----
Agreement:
The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with
.the provisions of'TTL, 5 of the State Sanitary Code—The undersigned further agrees not to place the system in
operation until a Certificate of Compliance has been iss d by he b and iealth.
Sne -- -/ ............: --•--•.....-••••-•--•-•_. ................
D....... .APPlication Approved BY ..._ _ .. z3. ............
Date
Application Disapproved for the following reasons-------------------------------------------------------------------------------------••----.........•••..........
---•--•-•-•......................................••----------...-----•-----------•------------------••----•••--•-•-••----••••-•••••-•---•••--•••-••---------•-•---•-••••••--•••------••--••----••••-•---
Date
PermitNo......................................................... Issued.......................................................
Date e
Fps..............................
THE COMMONWEALTH OF MASSACHUSETTS ,•
BOARD OF HEALTH
......... . .........................OF*....... ....... '
ApplirFatiun for Difiposaal i9orkii Tonutrnrtiun ramit
Application is hereby made for a Permit to Construct ( ) or Repair ( ) an Individual Sewage Disposal
System at:
-&5..."e1T_G_I C'C ...'` �'�.............•..... --------..-------• •--- . ...- ----------------•---•----------•----•--
Location-Address r or Lot No.
2ae
.. O ei"' ....Add ___...^.........4 -•••-•-••-
Installer Address ,F
Type of Building Size Lot............................Sq. feet
U Dwelling�'No. of Bedrooms ._...Expansion Attic ( ) Garbage Grinder ( )
Other—T e of Building No. of persons............................ Showers Cafeteria
a' Other fixtures ----------------•-.........---•- -
W Design Flow............................................gallons per person per day. Total daily flow............................................gallons.
WSeptic Tank—Liquid capacity............gallons Length................ Width................ Diameter................ Depth................
x Disposal Trench—No. .................... Width.................... Total Length.................... Total leaching area...................sq. ft.
Seepage Pit No..................... Diameter.................... Depth below inlet.................... Total leaching area..................sq. ft.
Z Other Distribution box ( ) Dosing tank ( )
Percolation Test Results Performed by................... ...................................................... Date........................................
Test Pit No. I................minutes per inch Depth of Test Pit.................... Depth to ground water........................
Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................
O Description of Soil....._w- '.".-d-
:.. -- ---- - - ---- - -
W -•••-••-•---------------•---•-------•------•---•---•--•-••.
; --- ----- -------•- -------------
UNature _Repair or A erat' ns—Answer en applicable... ' :-. ...................� C �
•-' � .. - =�,✓ ........:..............................................................................................................
Agreement:
The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with
the provisions of TITIE 5 of the State Sanitary Code—The undersigned further agrees not to place the system in
operation until a Certificate of Compliance has been .ss ed by he bard health. q
Signed ---- l
.y. .................
f/ /� Date
Application Approved By...... .... " „
Date
Application Disapproved for the following reasons:.............................................--------••------------------------------------------.......------
......-•-------••----•-------•-•--•----••-•--•••-----••--•--------•---•---•----•------------------------••-----•----•-------•-•••-•-----•-•-----•-•---•--••-•-•--•••••---••-----••----•-•-•--•----------
Date
PermitNo......................................................... Issued------...--------------------------...................
Date
THE COMMONWEALTH OF MASSACHUSETTS
BOARD OF HEALTH
...........r.. O F....
.d` ........ ............
�rr�if irtt#le of f�unt�ltaanrr
THIS IS TO CERTIFY, That the Individual Sewage Disposal System constructed ( ) or Repaired ((.•}
Installer--•-•------------•----•-----•-........---•--••.......................................................
-
_..
..+:
has been installed in accordance with the provisions of TITLE 5 of The State Sanitary Code as described in the
application for Disposal Works Construction Permit No.. ._�' ..sel.............. dated................................................
THE ISSUANCE OF THIS CERTIFICATE SHALL OT BE CONSTRUED AS A GUARANTEE THAT THE
SYSTEM WILL FUNCTION SATISFACTORY.
DATE.............................`_/.�.`:l 5-kel ......... Inspector---
--
THE COMMONWEALTH OF MASSACHUSETTS
BOARD OF HEALTH
OF.........* .................................. 5-
FEE........................
Disposal Works ,Tonutr ion amit
Permissionis hereby granted.............Z- -------- — -------------------=--•----------------------------.--..-..----•----•-------.---.-•-•--- i
to Construct ( ) or Repair ( W/an Individual Sewage Disposal System 3
atNo...._.-•-; ....'�eg' R . .......j d,,,,.... ._ .--__...--
Street
as shown on the application for Disposal Works Construction Permit No..................... Ilated.._.-_._....._............................
of Bath
DATE------------------------- -------•---- -----.
FORM 1255 HOBBS & WARREN, INC.. PUBLISHERS
r
COMMONWEALTH OF MASSACHUSETTS
EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS
DEPARTMENT OF ENVIRONMENTAL PROTECTION
RECEIVED
OCT 2 8 2003
TOWN OF BARNSTABLE
TITLE 5 HEALTH DEPT.
OFFICIAL INSPECTION FORM- NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART A
CERTIFICATION .
Property Address: 148 Robbins Street MAP
Osterville, MA 02655 PARCEL
Owner's Name: Mike Dadarria LOT '7 3
Owner's Address: - ---
Date of Inspection: October 3;.2003
Name of Inspector:(Please Print) James M. Ford
Company Name: James M. Ford
Mailing Address: P.O. Box 49
Osterville,MA 02655-0049
Telephone Number: (508)862-9400
CERTIFICATION STATEMENT
I certify that I have personally inspected the sewage disposal system at this address and that the information reported
below is true,accurate and complete as of the time of the inspection. The inspection was performed based on my
training and experience in the proper function and maintenance of on site sewage disposal systems. •I am a DEP
approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000). The system:
✓ Passes
Conditionally Passes
Neods Further Evaluation by the Local Approving Authority
Fai s
Inspector's Signature: Date: October 9, 2003
The system inspector shall sub it a copy of this inspection report to the Approving Authority(Board of Health or
DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000
gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the
DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable,and the approving
authority.
Notes and Comments
****This report only describes conditions at the time of inspection and,under the conditions of use at that
time. This inspection does not address how the system will perform in'the future under the same or different
conditions of use.
Title 5 Inspection Form 6/15/2000 page 1
R
J
Page 2 of I 1
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 148 Robbins Street
Osterville• MA
Owner: Mike Dadarria
Date of Inspection: October 3. 2003
Inspection Summary: Check A,B,C,D or E/ALWAYS complete all of Section D
A. System Passes:
✓ I have not found any information which indicates that any of the failure criteria described in 310 CMR
15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below.
Comments:
B. System Conditionally Passes:
One or more system components as described in the"Conditional Pass"section need to be replaced or
repaired. The system,upon completion of the replacement or repair,as approved by the Board of Health,will pass.
Answer yes,no or not determined(Y,N,ND)in the for the following statements. If"not determined",please
explain.
The septic tank is metal and over 20 years old*or the septic tank(whether metal or not)is structurally
unsound,exhibits substantial infiltration or"filtration or tank failure is imminent. System will pass inspection if the
existing tank is replaced with a complying septic tank as approved by the Board of Health.
*A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance
indicating that the tank is less than 20 years old is available.
ND explain:
Observation of sewage backup or break out or high static water level in the distribution box due to broken or
obstructed pipe(s)or due to a broken,settled or uneven distribution box. System will pass inspection if (with
approval of Board of Health):
broken pipe(s)are replaced
obstruction is removed ;
distribution box is leveled or replaced r °
ND explain:
The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will
pass inspection if(with approval of the Board of Health):
broken pipe(s)are replaced ,
obstruction is removed
ND explain:
2
ti
Page 3 of 11
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 148 Robbins Street _
Osterville. AM
Owner: Mike Dadarria
Date of Inspection: October 3, 2003
C. Further Evaluation is Required by the Board of Health:
Conditions exist which require further evaluation by the Board of Health in order to determine if the system
is failing to protect public health,safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the
system is not functioning in a manner which will protect public health,safety and the environment:
Cesspool or privy is within 50 feet of a surface water
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
2. System will fail unless the Board of Health(and Public Water Supplier,if any)determines that the
system is functioning in a manner that protects the public health,safety and environment:
_ The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a
surface water supply or tributary to a surface water supply.
The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply.
The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well.
_ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a
private water supply well*". Method used to determine distance
"This system passes if the well water analysis,performed at a DEP certified laboratory, for coliform
bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and
the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other
failure criteria are triggered. A copy of the analysis must be attached to this form.
3. Other:
3
Page 4 of 11
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 148 Robbins Street
Osterville, AM
Owner: Mike Dadarria
Date of Inspection: October 3, 2003
D. System Failure Criteria applicable to all systems:
You must indicate either`yes"or"no"to each of the following for all inspections:
Yes No
✓ Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool
✓ Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or
clogged SAS or cesspool
✓ Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or
cesspool
✓ Liquid depth in cesspool is less than 6"below invert or available volume is less than '/z day flow
✓ Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number
of times pumped_.
_ ✓ Any portion of the SAS,cesspool or privy is below high ground water elevation.
✓ Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface
water supply. _
✓ Any portion of a cesspool or privy is within a Zone 1 of a public well.
✓ Any portion of a cesspool or privy is within 50 feet of a private water supply well.
✓ Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water
supply well with no acceptable water quality analysis. [This system passes if the well water analysis,
performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds
indicates that the well is free from pollution from that facility and the presence of ammonia
nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria
are triggered. A copy of the analysis must be attached to this form.]
No (Yes/No)The system fails. I have determined that one or more of the above failure criteria exist as
described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of
Health to determine what will be necessary to correct the failure.
E. Large System:
To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000
gpd•
You must indicate either"yes"or"no"to each of the following:
(The following criteria apply to large systems in addition to the criteria above)
Yes No
the system is within 400 feet of a surface drinking water supply
the system is within 200 feet of a tributary to a surface drinking water supply
the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or a mapped
Zone II of a public water supply well
If you have answered"yes"to any question in Section E the system is considered a significant threat,or answered
"yes"in Section D above the large system has failed. The owner or operator of any large system considered a
significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR
15.304. The system owner should contact the appropriate regional office of the Department.
4
r
v
° Page 5 of 11
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECKLIST
Property Address: 148 Robbins Street
Osterville, MA
Owner: Mike Dadarria
Date of Inspection: October 3, 2003
Check if the following have been done: You must indicate`yes"or"no"as to each of the following:
Yes No
✓ Pumping information was provided by the owner,occupant,or Board of Health
✓ Were any of the system components pumped out in the previous two weeks?
✓ Has the system received normal flows in the previous two week period?
✓ Have large volumes of water been introduced to the system recently or as part of this inspection ?
✓ Were as built plans of the system obtained and examined?(If they were not available note as N/A)
✓ Was the facility or dwelling inspected for signs of sewage back up?
✓ Was the site inspected for signs of break out?
✓ Were all system components,excluding the SAS,located on site?
✓ Were the septic tank manholes uncovered,opened,and the interior of the tank inspected for the condition
of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum ?
✓ _ Was the facility owner(and occupants if different from owner)provided with information on the proper
maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System(SAS)on the site has been determined based on:
Yes No
✓ Existing information. For example,a plan at the Board of Health.
✓ _ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of distance
is unacceptable)[310 CMR 15.302(3)(b)].
5
s.
Page 6 of 1 I
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION
Property Address: 148 Robbins Street
Osterville, AM
Owner: Mike Dadarria
Date of Inspection: October 3, 2003
FLOW CONDITIONS
RESIDENTIAL
Number of bedrooms(design): 3 Number of bedrooms(actual): 3
DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms): 330
Number of current residents: 0
Does residence have a garbage grinder(yes or no): No
Is laundry on a separate sewage system(yes or no): No [if yes separate inspection required]
Laundry system inspected(yes or no): No
Seasonal use(yes or no): No
Water meter readings, if available(last 2 years usage(gpd)): Unavailable
Sump Pump(yes or no): No
Last date of occupancy: Unknown
COMMERCIAL/INDUSTRIAL
Type of establishment:
Design flow(based on 310 CMR 15.203): gpd
Basis of design flow(seaWpersons/sgft,etc.):
Grease trap present(yes or no):
Industrial waste holding tank present(yes or no)
Non-sanitary waste discharged to the Title 5 system(yes or no):
Water meter readings, if available:
Last date of occupancy/use:
OTHER(describe):
GENERAL INFORMATION
Pumping Records
Source of information: Unavailable
Was system pumped as part of the inspection(yes or no):
If yes,volume pumped: gallons--How was quantity pumped determined?
Reason for pumping:
TYPE OF SYSTEM
✓ Septic tank,distribution box,soil absorption system
Single cesspool
Overflow cesspool
Privy
Shared system(yes or no) (if yes,attach previous inspection records, if any)
Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be
obtained from system owner)
Tight Tank Attach a copy of the DEP approval
Other(describe):
Approximate age of all components,date installed(if known)and source of information:
Unknown
Were sewage odors detected when arriving at the site(yes or no): No
6
Page 7 of I I
OFFICIAL INSPECTION FORM- NOT-FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 148 Robbins Street '
Osterville, MA
Owner: Mike Dadarria
Date of Inspection: October 3, 2003
BUILDING SEWER(locate on site plan)
Depth below grade:
Materials of construction: _cast iron _40 PVC other(explain):
Distance from private water supply well or suction line:
Comments(on condition of joints,venting,evidence of leakage,etc.):
SEPTIC TANK: ✓ (locate on site plan)
Depth below grade: 10"
Material of construction: ✓ concrete _metal _fiberglass _polyethylene
_other(explain)
If tank is metal list age: Is age confirmed by a Certificate of Compliance(yes or no): (attach a copy of
certificate)
Dimensions: 1000 gal. '
Sludge depth: 2"
Distance from top of sludge to bottom of outlet tee or baffle: 30
Scum thickness: 1"
Distance from top of scum to top of outlet tee or baffle: 8"
Distance from bottom of scum to bottom of outlet tee or baffle: 10"
How were dimensions determined: Measuring stick
Comments(on pumping recommendations,inlet and outlet tee or baffle condition,structural integrity, liquid levels
as related to outlet invert,evidence of leakage,etc.): '
Tees were present. The liquid level was even with the outlet invert There did not appear to be any signs of leakage
GREASE TRAP: None (locate on site plan)
Depth below grade:
Material of construction: _concrete metal _fiberglass Polyethylene _other
(explain):
Dimensions:
Scum thickness:
Distance from top of scum to top'of outlet tee or baffle:
Distance from bottom of scum to bottom of outlet tee or baffle:
Date of last pumping:
Comments(on pumping recommendations,inlet and outlet tee or baffle condition,structural integrity, liquid'levels
as related to outlet invert,evidence of leakage,etc.):
7
y
Page 8 of 1 1
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 148 Robbins Street
Osterville, MA
Owner: Mike Dadarria
Date of Inspection: October 3, 1003
TIGHT or HOLDING TANK: None (tank must be pumped at time of inspection)(locate on site plan)
Depth below grade:
Material of construction: _concrete _metal _fiberglass _polyethylene _other(explain):
Dimensions:
Capacity: Gallons
Design Flow: gallons/day
Alarm present(yes or no):
Alarm level: Alarm in working order(yes or no):
Date of last pumping:
Comments(condition of alarm and float switches,etc.):
DISTRIBUTION BOX: None (if present must be opened)(locate on site plan)
Depth of liquid level above outlet invert:
Comments(note if box is level and distribution to outlets equal,any evidence of solids carryover,any evidence of
leakage into or out of box,etc.):
PUMP CHAMBER: None (locate on site plan)
Pumps in working order(yes or no):
Alarms in working order(yes or no)
Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.):
8
i
Page 9 of 1 I
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 148 Robbins Street
Osterville, MA
Owner: Mike Dadarria
Date of Inspection; October 3, 2003
SOIL ABSORPTION SYSTEM(SAS): ✓ (locate on site plan,excavation not required)
If SAS not located explain why:
Type
✓ leaching pits,number: 1-6'x 6'(1000 gal.)
leaching chambers,number:
leaching galleries,number:
leaching trenches,number, length:
leaching fields,number,dimensions:
✓ overflow cesspool,number: 1-5'W x 7'T x 9'bottom to grade
Innovative/alternative system Type/name of technology:
Comments(note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.):
The leach pit was dry. The scum line was approximately]'up. There did not appear to be any signs offailure. The cover was
2'6"below grade. The bottom to grade was 9'. The overflow cesspool had 6"ofwater on the bottom. The cover was 20"below.
CESSPOOLS: None (cesspool must be pumped as part of inspection)(locate on site plan)
Number and configuration:
Depth-top of liquid to inlet invert:
Depth of solids layer:
Depth of scum layer:
Dimensions of cesspool:
Materials of construction:
Indication of groundwater inflow(yes or no):
Comments (note condition of soil,signs of hydraulic failure;level of ponding,condition of vegetation,etc.):
PRIVY: None (locate on site plan)
Materials of construction:
Dimensions:
Depth of solids:
Comments(note condition of soil,signs of hydraulic failure, level of ponding,condition of vegetation,etc.):
9
n
Page 10 of 11
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 148 Robbins Street
Osterville, AM
Owner: Mike Dadarria
Date of Inspection: October 3, 2003 "
SKETCH OF SEWAGE DISPOSAL SYSTEM
Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks'or
benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building.
t.
3 Ss a6
1 O
y .
3
10
tf ,
m
Page 11 of 11
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 148 Robbins Street
Osterville, MA
Owner: Mike Dadarria
Date of Inspection: October 3, 2003
SITE EXAM
Slope
Surface water
Check cellar
Shallow wells
Estimated depth to ground water 30 +/- feet
Please indicate(check)all methods used to determine the high ground water elevation:
Obtained from system design plans on record- If checked,date of design plan reviewed:
Observed site(abutting property/observation hole within 150 feet of SAS)
✓ Checked with local Board of Health-explain:topographic and water contours maps
Checked with local excavators, installers-(attach documentation)
Accessed USGS database-explain:
You must describe how you established the high ground water elevation:
Using the Barnstable topographic map and the Cape Cod Commission water contours man,the maps were showing approximately
30'+1-to groundwater at this site.
This report has been prepared and the system inspected and passed as of the date of inspection. This report is
not a warranty or guarantee that the system will function properly in the future. There have been no warranties
or guarantees, either expressed,written or implied, relating to the system, the inspection and/or this report.
I1
- L TOWN OF BARNSTABLE
LUCATIE,— ( ! �d� .S : V. SEWAGE #
VILLAGE. (I S I eXV,I4- ASSESSOR'S MAP & LOT f yol' I0S-'
INSTALLER'S NAME&PHONE NO. LQT '73
SEPTIC TANK CAPACITY p )
LEACHING FACILITY: (type) �l 4- �x6 (size) /M (5"!
NO. OF BEDROOMS 3
BUILDER OR OWNER /)I1 WL
PERMITDATE: COMPLIANCE DATE:
Separation Distance Between the:
Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet
Private Water Supply Well and Leaeting Facility (If any wells exist
on site or within 200 feet of leaching facility) Feet
Edge of Wetland and Leaching Facility(If any wetlands exist
within 300 feet of leachi g facility) / J Feet-
Furnished by Z2,, t
aq s
y ao 39 O
1
4
� y
TOWN OF BARNSTABLE y�
LOCATION � � ����1 j� S 1 SEWAGE #
VILLAGE �5� -�•t �Z-- ASSESSOR'S MAP &LOT
INSTALLER'S NAME&PHONE NO.
SEPTIC TANK CAPACITY
LEACHING FACILITY: (type) (size)
NO. BEDROOMS
BUILDER OR OWNER
PERMITDATE: COMPLIANCE DATE:
Separation Distance Between the:
Maximum Adjusted Groundwater Table and Bottom of Leaching Facility Feet
Private Water Supply Well and Leaching Facility (If any wells exist
on site or within 200 feet of leaching facility) Feet
Edge of Wetland and Leaching Facility(If any wetlands exist
within 300 feet of leaching facility) Feet
Furnished by
� o
r �
s
Q
wN
vli
` '. W
LOCATION rsEWAGE NO.
VILLAGE
INSTA LLER'S NAME i ADDRESS
'R OR OWN ER
DATE PERMIT ISSUED
DAT E COMPLIANCE ISSUED
��
��
�r
�� ��
��
.�
.,�
/�
�,
'� ��� � ��
.., � ,�
4
/or
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
148 Robbins Street m
Property Address
Mary Jaros
Owner Owner's Name
information is
required for every Osterville Ma 02655 11-21-16
page. City/Town State ,Zip Code Date of Inspection
.A
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
Important:When filling out forms A. General Information
on the computer,
use only the tab 1. Inspector:
key to move your
cursor-do not Matthew Gilfoy
use the return key. Name of Inspector
•
Excavation
Company
� Company Name ,
374 Route 130
Company Address
Sandwich Ma 02563
City/Town State Zip Code
508 477-0653 S113640
Telephone Number License Number
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information reported below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of
Title 5(310 CMR 15.000).The system: -
® Passes ❑ Conditionally Passes ❑ Fails
❑ Needs Further Evaluation by the Local Approving Authority
11-21-16
Inspector's Signature Date
The system inspector shall submit a copy of this inspection report to the Approving Authority(Board
of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or
has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the
'report to the appropriate regional office of the DEP. The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use
at that time.This inspection does not address how the system will perform in the future under
the same or different conditions of use.
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 1 of 17
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is required for every Osterville Ma 02655 11-21-16
page. Cityrrown State Zip Code Date of Inspection
B. Certification (cont.)
Inspection Summary: Check A,B,C,D or E/always complete all of Section D
A) System Passes:
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
System was in working condition at time of inspection.
B) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Pass"section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes", "no"or"not determined" (Y, N, ND)for the following statements. If"not
determined,"'please explain.
The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally
unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass
inspection if the existing tank is replaced with a complying septic tank as approved by the Board of
Health.
*A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND(Explain below):
t5ins-3l13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 2 of 17
t
I
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form=Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is required for every Osterville Ma 02655 11-21-16
page. Cityrrown State Zip Code Date of inspection
B. Certification (cont.)
❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
B) System Conditionally Passes (cont.):
❑ Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND(Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below):
❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND(Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below):
C) Further Evaluation is Required by the Board of Health: .
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 17
Commonwealth of Massachusetts -
w Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
148 Robbins Street y,_a
Property Address
Mary Jaros
Owner Owner's Name
information is Osterville Ma D2655 11-21-16
required for every _
page. Citylrown 4 State . Zip Code Date of Inspection
B. Certification (cont.) . p '
;t
2. System will fail unless the Board of Health (and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption systern (SAS)and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well. .
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well".
Method used to determine distance:
**This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must
be attached to this form.
3: Other:
D) System Failure Criteria Applicable to All Systems:
You must indicate"Yes"or"No"to each of the following for all inspections:
Yes No m
E ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
Discharge or ponding of effluent to the surface of the ground or surface waters
❑ , ® due to an overloaded or clogged SAS or cesspool
Static liquid level in the distribution box above outlet invert due to an overloaded
❑ ® or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6"-below invert or available volume is less
than 1/day flow
t5ins-3/13 - Title 5 Official Inspection form:Subsurface Sewage Disposal System-Page 4 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form ,
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
M 148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is required for every Osterville Ma 02655 11-21-16
page. Cityrrown State Zip Code Date of Inspection
B. Certification (cont)
Yes No
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
® Any,portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a_surface water supply or
tributary to a surface water supply:,
❑ ® Any portion of a cesspool or privy is within,a Zone 1 of a public well.
❑ Z Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water.quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered.A copy of the analysis
and chain of custody must be attached to this form.]
❑ ® The system is a cesspool serving a facility with a design flow of 2000gpd-
10,000gpd.
❑ ® The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 16.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
E) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the
questions in Section D.
Yes No
El EI the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet.of a tributary to a surfacedrinking water supply
❑ the system is located in a nitrogen sensitive area(Interim Wellhead Protection
Area—IWPA)or a mapped Zone II of a public water supply well
If you have answered"yes"to any question in Section E the system is considered a significant threat;
or answered"yes" in Section D above the large system has failed. The owner or operator of any large
system considered a significant threat under Section E or failed under Section D shall upgrade the
system in accordance with 310 CMR 15.304. The system owner should contact the appropriate
regional office of the Department.
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 5 of 17
Commonwealth of Massachusetts y
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is required for every Osterville Ma 02655 11-21-16
page. Citylrown State Zip Code Date of Inspection
C. Checklist
Check if the following have been done. You must indicate"yes"or"no"as to each of the following:
Yes No
❑ ® Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
❑ ® Has the system received normal flows in the previous two week period?
❑ ® Have large volumes of water been introduced to the system recently or as part of
this inspection?.
® Were as built plans of the system obtained and examined?(If they were not
available note as N/A)
❑ ® Was the facility or dwelling inspected for signs of sewage back up?
® ❑ Was the site inspected for signs of break out?
® ❑ Were all system components, excluding the SAS, located on site?
S ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
❑ ® _ Was the facility owner(and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System(SAS)on the site has
been determined based on:
® ❑ Existing information. For example, a plan at the Board of Health.
❑ ® Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable)[310 CMR 15.302(5)]
D. System Information
Residential Flow Conditions:
Number of bedrooms(design): 3 -Number of bedrooms(Actual) _3
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): None
provided
l5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form.=Not for Voluntary Assessments
w 148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is
required Osterville t Ma 02655 11-21-16
_
page. Cityrrown State Zip Code Date of Inspection
D. System Information
Description:
Number of current residents: 0
Does residence have a garbage grinder? ❑ Yes ® No
Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No
information in this report.)
Laundry system inspected? ❑ Yes ® No
Seasonaluse? ❑ Yes ® No
Water meter readings, if available last 2 ears usage d See below
9 ( Y 9 (gP ))�
Detail:
2014-20,000gallons 2015- 18,000gallons
Sump pump? ❑ Yes ® No
Last date of occupancy: Sept-2016
Date
Commercial/Industrial Flow Conditions:
Type of Establishment: NA
Design flow(based on 310 CMR 15.203): Gallons per day(gpd)
Basis of design flow(seats/persons/sq.ft., etc.):
Grease trap present? ❑ Yes ❑ No
Industrial waste holding tank present? ❑ Yes ❑ No
Non-sanitary waste discharged to the Title 5 system? ❑.Yes ❑ No
Water meter readings, if available:
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 17
y
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
�.w 148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is
required for every Osterville Ma 02655 11-21-16
page. Cityrrown State Zip Code Date of Inspection
D. System Information (cont.)
Last date of occupancy/use: Date
Other(describe below):
General Information
Pumping Records:
Source of information: Owner-last pumped May 2015
:i
Was system pumped as part of the inspection? ❑ Yes ® No
If yes, volume pumped: gallons
• R
How was quantity pumped determined?
Reason for pumping:
Type of System:
® Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
❑ Shared system (yes or no) (if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology.Attach a copy of the current operation and
maintenance contract(to be obtained from system owner)and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other(describe):
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of W
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is required for every Osterville Ma 02655 11-21-16
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Approximate age of all components, date installed(if known)and source of information:
Most recent permit for a new leachpit was dated 9-23-91
Were sewage odors detected when arriving at the site? ❑ Yes ® No
Building Sewer(locate on site plan):
Depth below grade: 2'
feet
Material of construction:
® cast iron E 40 PVC ❑other(explain):
Distance from private water supply well or suction line: Town
feet
Comments (on condition of joints, venting; evidence of leakage, etc.):
Septic Tank(locate on site plan):
Depth below grade: 1
feet
Material of construction:
® concrete ❑ metal ❑ fiberglass" ❑ polyethylene ❑other(explain)
If tank is metal, list age: years
Is age confirmed by a Certificate of Compliance?(attach a copy of certificate) ❑ Yes ❑ No
Dimensions: 1000 Gallons
Sludge depth: 2
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 9 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is required for every Osterville Ma 02655' 11-21-16
page. Cityrrown State Zip Code Date of Inspection
D. System Information (cont.)
Septic Tank(cont.)
Distance from top of sludge to bottom of outlet tee or baffle 34"
Scum thickness 0
11
Distance from top of scum to top of outlet tee or baffle 6, -
Distance from bottom of scum to bottom of outlet tee or baffle 1
How were dimensions determined? Measured
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage;etc.):
Tank was in working order at time of inspection with liquid level equal to outlet invert. Tank is not in
need of pumping at this time but should be pumped every two years for maintenance.
Grease Trap(locate on site plan):
'Depth below grade- NA
Material of construction:
❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑other(explain):
Dimensions: —
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping: Date
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 10 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is required for every Osterville Ma 02655 11-21-16
page. Cityrrown State Zip Code Date of Inspection
D. System Information (cont.)
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Tight or Holding Tank(tank must be pumped at time of inspection)(locate on site plan):
Depth below grade: NA
Material of construction:
❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain):
Dimensions:
Capacity:
gallons
Design Flow:
gallons per day
Alarm present: ❑ Yes ❑ No
Alarm level: Alarm in working order: ❑ Yes ❑ No
Date of last pumping: Date
Comments(condition of alarm and float switches, etc.):
*Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 17
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is required for every Osterville Ma 02655 11-21-16
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Distribution Box (if present must be opened) (locate on.site plan):
Depth of liquid level above outlet invert NA
Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
Pump Chamber(locate on site plan):
Pumps in working order: ❑ Yes ❑ No*
Alarms in working order: ❑ Yes ❑ No*
Comments(note condition of pump chamber, condition of pumps and appurtenances, etc.):
NA
*If pumps or alarms are not in working order, system is a conditional pass.
Soil Absorption System (SAS)(locate on site plan, excavation not required):
If SAS not located, explain why:
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 12 of 17
Commonwealth of Massachusetts
Title 5 Official 'Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
M 148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is Osterville Ma 02655 11-21-16
required for every -
page. City/Town State Zip Code Date of Inspection
D. System Information(cont.)
Type:
® leaching pits number:
(1) 6'x6'
❑ leaching chambers number:
❑ leaching galleries number:
❑ leaching trenches number, length:
❑ leaching fields number, dimensions:
® overflow cesspool 'number: (1) 6'X8'
❑ innovative/alternative system
Type/name of technology:
Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
Leaching was in working order at time of inspection. The leachpit was dry with no sign of previous
backup and the cesspool had 1'of standing water.
Cesspools (cesspool must be pumped as part of inspection)(locate on site plan):
Number and configuration NA
Depth—top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
I •
Indication of groundwater inflow ❑ Yes ❑ No
t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 17
Commonwealth of Massachusetts
w Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is
required for every Osterville Ma 02655 11-21-16
page. Cityrrown State Zip Code Date of Inspection
D. System Information (cont.)
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
Privy(locate on site plan):
Materials of construction: NA
Dimensions
Depth of solids
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 17
v
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
wM 148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is
required for every Osterville Ma 02655 11-21-16
page. Citylrown State Zip Code Date of Inspection
D. System Information (cont.)
Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to
at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate
where public water supply enters the building. Check one of the boxes below:
® hand-sketch in the area below
❑ drawing attached separately
REAR
Al-411" 13111'`
A2.4 , 82017,
A3=5v 83.26`
M-W 134a 3 '
2
3
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 17
Commonwealth of Massachusetts
- , Title 5 Official Inspection Form
_ Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros -
Owner Owner's Name
information is required for every Osterville Ma 02655 11-21-16
page. CityrFown State Zip Code Date of Inspection
D. System Information (cont.) b
Site Exam:,
® Check Slope
® Surface water
® Check cellar
® Shallow wells
Estimated depth to high ground water: >12'
feet
Please indicate all methods used to determine the high ground water elevation:
ET Obtained from system design plans on record
If checked, date of design plan reviewed: pate
❑' Observed site(abutting property/observation hole within 150 feet of SAS)
® Checked with local Board of Health-explain:
An existing inspection where town maps_and charts were used so no high ground water
in the area:
❑ Checked with local excavators, installers-(attach documentation)
❑, ' Accessed USGS database-explain: '.
- s
You must describe how you established the high ground water elevation:
Information providedby BOH
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 17
Commonwealth of Massachusetts'
'Himr Title 5 Official Inspection .Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
148 Robbins Street
Property Address
Mary Jaros
Owner Owner's Name
information is required for every Osterville Ma 02655 11-21-16
page. City/Town State . Zip Code Date of inspection
E. Report Completeness Checklist
Z Inspection Summary:A, B, C, D, or E checked
®Inspection Summary D (System Failure Criteria Applicable to All Systems)completed
® System Information—Estimated depth to high groundwater
® Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 17