HomeMy WebLinkAbout0170 STURBRIDGE DRIVE - Health 170 Sturbridge Drive Osterville A= 166-112 Commonwealth of Massachusetts Title 5 Official Inspection Fora Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29 2011 required for every p , page. City/Town State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important:When filling out forms A. General Information on the computer, / use only the tab 1. Inspector: key to move your VVVIII V cursor-do not David B. Mason use the return Name of Inspector key. David B. Mason Company Name 4 Glacier Path �I Company Address East Sandwich MA 02537 City/Town State Zip Code 508-367-1617 S1287 Telephone Number License Number 3 k CD B. Certification o I certify that I have personally inspected the sewage disposal system at this address and that t6 g- information reported below is true, accurate and complete as of the time of the inspection. Tfxe?inspeedtion was performed based on my training and experience in the proper function and maintenance.of on sate sewage disposal systems. I am a DEP approved system inspector pursuant to Section.15 i40 of- Title 5(310 CMR 15.000). The system: s ® Passes ❑ Conditionally Passes ❑ Fails ❑ Needs Further Evaluation by the Local Approving Authority 0September 29, 2011 Inspe Si '�fu?e Date The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system,is a shared system or has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. ****This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. I � l t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewa Disposal System•Page 1 of 17 Commonwealth of Massachusetts . Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments .°' 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner . Owner's Name information is Osterville MA 02564 September 29 2011 required for every p , page. Cityrrown State Zip Code Date of Inspection B. Certification (cont.) Inspection Summary: Check A,B,C,D or E/always complete all of Section D A) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: This inspection information represents the condition of the system on September 29, 2011 at 10:30 AM and only that date and time nor does the inspection guarentee the future operation of the system. B) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no" or"not determined" (Y, N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND (Explain below): t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29, 2011 required for every p page. Cityrrown State Zip Code Date of Inspection B. Certification (cont.) B) System Conditionally Passes (cont.): ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction.is removed ❑ Y ❑ N ❑ ND (Explain below): ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): C) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 3 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is . Osteryille MA 02564 September 29 2011 required for every p , page. City/Town State Zip Code Date of Inspection B. Certification (cont.) 2. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well". Method used to determine distance: This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: D) System Failure Criteria Applicable to All Systems: You must indicate"Yes" or"No"to each of the following for all inspections: Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than Y2 day flow t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29, 2011 required for every P page. Cityrrown State Zip Code Date of Inspection B. Certification (cont.) Yes No ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis and chain of custody must be attached to this form.] ❑ ❑ The system is a cesspool serving a facility with a design flow of 2000gpd- 10,000gpd. ❑ ❑ The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the questions in Section D. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area—IWPA)or a mapped Zone II of a public water supply well If you have answered "yes"to any question in Section E the system is considered a significant threat, or answered "yes" in Section D above the large system has failed.The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. t5ins.•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 17 Commonwealth of Massachusetts . Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29,required for every p 2011 page. Citylrown State Zip Code Date of Inspection C. Checklist Check if the following have been done. You must indicate"yes"or"no"as to each of the following: Yes No ❑ ® Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ❑ ® Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ❑ ® Were as built plans of the system obtained and examined?(If they were not available note as N/A) ❑ ® Was the facility or dwelling inspected for signs of sewage back up? ❑ ® Was the site inspected for signs of break out? ❑-- ® Were all system components, excluding the SAS, located on site? ❑ ® Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ❑ ® Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ❑ ® Existing information. For example, a plan at the Board of Health. ❑ ® Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] D. System Information Residential Flow Conditions: Number of bedrooms(design): 3 Number of bedrooms(actual): 2 M 5.203 (for example: 110 gpd x#of bedrooms): 330 V ` t5ins•11/10. Title 5 Official Inspection Forth:Subsurface Sewage Disposal System•Page 6 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Fora Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29 2011 required for every P , page. Cityrrown State Zip Code Date of Inspection D. System Information Description: Number of current residents: 1 Does residence have a garbage grinder? ❑ Yes ® No Is laundry on a separate sewage system? [if yes separate inspection required] ❑ Yes ® No Laundry system inspected? ❑ Yes ® No Seasonal use? ❑ Yes ® No Water meter readings, if available(last 2 years usage (gpd)): Detail: 2009; 27,000gallons, 2010 39,000 gallons Sump pump? ❑ Yes ® No Last date of occupancy: Current Date Commercial/industrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15.203): Gallons per day(gpd) Basis of design flow(seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ❑ No Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? El Yes ❑ No Water meter readings, if available: t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments °M ,•'°r 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29, 2011 required for every p page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Last date of occupancy/use: Date Other(describe below): General Information Pumping Records: Source of information: Was system pumped as part of the inspection? ❑ Yes ® No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner)and a copy of latest inspection of the I/A'system by system operator under contract ❑ Tight tank. Attach a copy of the DEP approval. ❑ Other(describe): t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29, 2011 required for every p page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Approximate age of all components, date installed (if known)and source of information: December 1992 Were sewage odors detected when arriving at the site? ❑ Yes ® No Building Sewer(locate on site plan): Depth below grade: 24 Inches feet Material of construction: ❑ cast iron ® 40 PVC ❑ other(explain): Distance from private water supply well or suction line: 10, feet Comments(on condition of joints, venting, evidence of leakage, etc.): Appears in good condition Septic Tank(locate on site plan): Depth below grade: 16 Inches feet Material of construction: ® concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No Dimensions: Typical 1000 gallon tank Sludge depth: 4" t5ins-11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 9 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29 2011 required for every p page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Septic Tank(cont.) Distance from top of sludge to bottom of outlet tee or baffle 36" Scum thickness 3" Distance from top of scum to top of outlet tee or baffle 3" Distance from bottom of scum to bottom of outlet tee or baffle 12 How were dimensions determined? Scour Stick Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): No evidence of leaking. Effluent level with outlet invert. Grease Trap(locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Fora Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29 2011 required for every p , page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day Alarm present: ❑ Yes ❑ No Alarm level; Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments(condition of alarm and float switches, etc.): Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29 2011 required for every P , page. Cityfrown State Zip Code Date of Inspection D. System Information (cont.) Distribution Box(if present must be opened) (locate on site plan): Depth of liquid level above outlet invert Equal Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): Nothing noted Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No Alarms in working order: ❑ Yes ❑ No Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: Leaching pit exposed and it is a 6'x6' pit with approx. 1 foot of effluent standing in the pit. t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments �M 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29, 2011 required for every p page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Type: ® leaching pits number: 1 ❑ leaching chambers number: ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): No signs of hydraulic failure, ponding, damp soil or excessive vegetation growth. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth—top of liquid to.inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow ❑ Yes ❑ No t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29 2011 required for every p , page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): Privy (locate on site plan): Materials of construction: Dimensions Depth of solids Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29, required for every p 2011 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ❑ hand-sketch in the area below drawing attached separately t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 17 Commonwealth of Massachusetts . Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29 2011 required for every p , page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Site Exam: ® Check Slope ® Surface water ® Check cellar ❑ Shallow wells Estimated depth to high ground water: 25 feet feet Please indicate all methods used to determine the high ground water elevation: ® Obtained from system design plans on record If checked, date of design plan reviewed: Date ® Observed site(abutting property/observation hole within 150 feet of SAS) ® Checked with local Board of Health-explain: Ground water contour map ® :Checked with local excavators, installers-(attach documentation) ® Accessed USGS database-explain: You must describe how you established the high ground water elevation: gourndwater contour map and septic designs in the area Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form ;. Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 170 Sturbridge Drive, Osterville, MA Property Address Marie Morgan Owner Owner's Name information is Osterville MA 02564 September 29 2011 required for every p page. Cityrrown State Zip Code Date of Inspection E. Report Completeness Checklist E Inspection Summary: A, B, C, D, or E checked E Inspection Summary D(System Failure Criteria Applicable to All Systems)completed E System,Information—Estimated depth to high groundwater E Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file t5ins-11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 17 of 17 Assessing As-Built Cards Page 1 of 1 TOwN OF BARNSTA§LE / , r LOCATIONSIIe�FI`(t� ' SEWAGE VILLAGE ASSIESSOR'S MAP& LOT,-6 z INSTALLER'S NAME & PHONE NO. .� •-��� �.i SEPTIC TANK CAPACITY LEACHING FACILITY.-(type)_ sue) i'r0 !'wf NO. OF BEDROOMS PRIVATE WELL OR PUBLIC WATER BUILDER OR OWNER DATE PERMIT ISSUED: DATE COMPLIANCE ISSUED: j.1-let- VARIANCE GRANTED: Yes No t/ • 1 P . L'�� Ux f l j• r G httD://www.town.barnCt.AhlP.m2.tiC/AccPccincr/RAirii,znlav acn?mnnn0r_19911 ,00 1 No. _.. Ymc.. ••.............. THE COMMONWEALTH OF MASSACHUSETTS BOAR® OF HEALTH TOWN OF BARNSTABLE Allp irFa#ion for Dhip i al Works Tonotrnrtinn Prrntit Application is hereby made for a Permit to Construct ( ) or Repair ( ) an Individual Sewage Disposal System at: 121�%Eff-6 ..... -- •-•-•G° t5------------------•------•--• atio - ddress Z or t No „�'�7Z.�.<?:mil-.»�- -^- - -•- •- --�-----!__-`--'•=1,...:`lbr�i� ---�-- .........-. Own r -------•--....-•••••-•-••---...Address Installer Address U Type of Building Size Lot_45 aC_....Sq. feet .-t Dwelling—No. of Bedrooms____. _________________________________Expansion Attic ( ) Garbage Grinder ( ) Other—T e of Building No. of persons____________________________ Showers — Cafeteria dOther fixtures ------------------------•-----------------------------.•..-------------------------------------------------------------._.....--•-----.._...._••------ W Design Flow..............._SS_________________.gallons per person pe//r Py. Total daily flow_______ ��__. ......................._gallons. WSeptic Tank—Liquid capacity gallons Length�!_.fc1-.//___ Width`7.�Q Diameter________________ DepthS� x Disposal Trench—No..................... Width.................... Total Length__.__.__.__.____ Total leaching area....................sq. ft. Seepage Pit No......./.......... Diameter-------1_� _ Depth below inlet_____ Total leaching area.._.7.39....sq. ft. Z Other Distribution box ( ) Dosing tank ( ) l Percolation Test Results Performed by._ s_._�/1C .lT � ��: Date . ,1 _ -._.___._... Test Pit No. I...... -„_._minutes per inch Depth of Test Pit./Ze-5 Depth to ground water_./2-10.. f=, Test Pit No. 2................minutes per inch Depth of.Test Pit_/_2,..S.... Depth to ground water./VA/e5e---- r ------- ------------------------•-----•-•-----------------••-----------•--•••--•-••-•------......................................................... Description of Soil ...._.....d_:IS ..._?ZU� _ U%' 'Sl ............. x -------------------------- -------�---'-'5-:_l_2.-�--......9;22 c�'..V---��=� ---------------------------c.� UW ---------------------------------------T�72--------6'S—_4-4V,25--------------------------------------------------------------------------------------------------------------------- Nature of Repairs or Alterations—Answer when applicable............................................................................................ ---------------------------------------•---•---------------------------------------._.........-----------------------------------------------=•----------------....................................... Agreement: The undersigned agrees to install the aforedescribed Individual ewage System in accordance with the provisions of TITLE 5 of the State Environmental Coe//un tied further agrees not to place the s- system in operation until a Certificate of Compliance has' e 1 sued board�f"llth- Sined ------------- -- ------ -�----------------------------------- J... ---------------'Date.......---------- Application Approved By ------ -- -- -----------' -'------------ ---:_- ------- - -------- -- -- -- -- ----- ............... ------------ --------------------- Date Application Disapproved for the following reasons. .... ... ...................................... --------------------------------- ----...... -------- ------------ ... ............... ....----.........-- ---............-------------....------.......------. .....----- -- ......... Permit No. ---. - .... � ..�� Issued ------------ - -------Date ------------------- Date /"iN T" OW �F BARNSTABLE000 LOCATION SEWAGE # VILLAGE � "�/j ASSESSOR'S MAP & LOT 2. INSTALLER'S NAME & PHONE NO. .1 SEPTIC TANK CAPACITY e'-r--� ` LEACHING FACILITY:(type) d�xer /I .mot' (size) NO. OF BEDROOMS �� PRIVATE WELL OR PUBLIC WATER r� BUILDER OR OWNER �` �:'. ,_- DATE PERMIT ISSUED: 16 •- y� DATE COMPLIANCE ISSUED: ` -- VARIANCE GRANTED: Yes No t/ ... ,r. + , ti �� _ ��` �, ,�_ �� �. \� � ../ s 'I I� � 1 . f� No.. ......... Fps........ ._..... ........ THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE .� liratiun for Diupuual Workii Tomitrudiun 1hrutit Application is hereby made for a Permit to Construct,( ) or Repair ( ) an Individual Sewage Disposal System at: IN - -7a G o _9 ------------------------- ----••-----_..�...---------...------ ..._.._..-----------..........__.......-- o atio - Yldress or_Lot Nol. f X. ?G-- �y ------------------------------------------ ---v Z z:�%�.�e� caner Address .. . ' tilSl....................... . .................................................................................................. ins Address Type of Building Size Lot__�s0_ C)...Sq. feet Dwelling—No. of Bedrooms............................_...............Expansion Attic ( ) Garbage Grinder ( ) p, Other—Type of Building ____________________________ No. of persons............................ Showers ( ) — Cafeteria ( ) dOther fixtures ------------------------------------------------------••••----------•----••--••----••------- W Design Flow............................................gallons per person per�dy. Total d i y oyv.......................................... I o s// WSeptic Tank—Liquid*capacity�.__.____ allons Length________________ Width________ __ Diameter________-_____._ De th__.._________... Disposal Trench—No ____________________ Width_____..___._____.__ Total Length......... Total leaching area________.______ sq. ft. Seepage Pit No......../- ____ Diame,ter.___..__1.--'_� Depth below inlet......_�_. ..._. Total leaching area______�__3�__sq. ft. Z Other Distribution box ( ) Dosing t nk c� '-' Percolation Tcst Results Performed b , . V)C `IViIECelc -9/2 a Y Date = Test Pit No. I...___2 ._minutes per inch Depth of Test Pit_. z. Depth to ground water__.------ . { f=1 Test Pit No. 2................minutes per inch Depth of Test Pit--- Depth to ground water.__�............. _ - ------O Description of Soil........ U ?� U��-w -�U� CJ/ - ------------------•----------------------•---------•••-------------___----•-•---••---- UW ......................................... -----------=-5-,� ;�� .-------------------------------------------------------------------------•--------------.._..•------...-•---..... Nature of Repairs or Alterations—Answer"when applicable------------------------------------_............................................................ r '\ Agreement: The undersigned agrees to install the aforedescribed Individual.-Sewage Dis,os'a stem in accordance with the provisions of TITLE 5 of the State Environmental Code e unde ned=further agrees not to place it--- system in operation until a Certificate of Compliance has'bee Is de d by e board of'heal.th.- i ned - r -................ . -------- y Dare - Application Approved By ------- ------ -------................:----- Z' ........ �/-I f' 'j =--------..-- -----------.--- --... -.-- i` tf--- --- Dare Application Disapproved for the following reasons: ----- ------------------------------ - ------ ------------------------------------ -- ----------- --- - ---------------------------------------------- --- ......................................................... --.........................------------ Dare Permit No. ....- ---....-- -. -..-/... Issued .. ri-------------- Dare THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE Ter#tfira e of Compliance f THIS IS TO CERTIFY,That the Individual Sewage Disposal System constructed ( �l ) or Repaired ( ) by ............7F � �..--G•` �JI,S Installer at ------1-7v....._.STU /,b ..... 72�'(/ 6J i�'�- G'/GG --- ---------- -------------------------------------------------- has been installed in accordance with the provisions of TITLES f he KR jironmental Code as described in the application for Disposal Works Construction Permit No. -... ..-.-. � dated .... . .................................. THE ISSUANCE OF THIS CERTIFICATE SHALL NOT 13 tC" NS AS A GUARANTEE THAT THE SYSTEM WILL FUNCTION SATISFACTORY. DATE - ...-... a .... rl--.- .�..- ------------------ Inspector ----- THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE D No......... ............ FEE. �.......... Disposal Vorks Trumitrnr#iun famit -Permission is hereby granted____.___ !c_�.�_-�C_.1_1-- ----...•---•-•-•---•••-•-•••--••-••---•--__...-••-••-•--•---••--•-•-•--••....................... to Construct ( or Repair ( ) an Individual Sewage Disposal,Systgn at No. / � S 'Ci2 C'.2�t�G� ��.....................................5 i ,?l//L`G� r-- --------------------------------------- ----.......... Street �L! / as shown on the application for Disposal Works Construction Permit No. ._.�_...__ __7_:,Dated___....................................... i - ------••--------------•-•---•---...-------•-----•••--•-----•••------._ Board of HealthDATE_ ........ � FORM 36508 HOBBS&WARREN,INC..PUBLISHERS DES I ON CRI TER A : INVF-RT El- EVAT IONS: GENERAL NOTES: DESIGN FLOW; INVERT AT BUILDING: g a•�_�__ BEDROOMS AT-11-0 G. P. D. PER INVERT IN .SEPTIC TANK: I . THIS 'PLAN IS FOR THE DESIGN AND :l O 1. 5� AccEss covERs MUST > , CONSTRUCTION OF THE SEWAGE DISPOSAL d,S 0 FIRST_ 2� ra BEDROOM EOUAL S..�3 G. f . l) INVERT OUT SEPTIC TANK;, $�.__ FACILITY ONLY. F �= IDC�.ad BE WITHIN I2 OF Q .O ► BE LEVEL- � � hJ a GAf�'BAGE OR I NL)El;' INVERT IN Dlsr. Box: _-- _.��Q.00 I NI SH ORADE _- 4 PVC MIN. 2 OF INVERT OUT DISI . Box: 2. ALL CONSTRUCTION METHODS AND 5cNEDULE 40 � , PE'ASTONE SEPTIC TANK RF_QUI,RED: INVERT IN LEACH PIT: °II• core _ MATERIALS FOR THE SEPTIC SYSTEM =DAL. q •� . ,� •�- 314 - 1112A � G. I U. X i5o�o - (� t� qg, �$.0 L=�'--GAL, BOTTOM OF LEACH PIT: �I Gad SEPTIC TANK ryg`1,6A�1{ ., v u 1 GAL � plA. WASHED ' SEPTIC TANK PROVIDED,, Io' MIN. �, uap -- ADJUSTED GROUND WATER: -� STONE TITLE 5 AND -LOCAL BOARD OF HEALTH D aox' [e; - OBSERVED GROUND WATER: 1,AQN . SHALL CONFORM TO MASS. D. E. P. 3 "OUTLET q►, a �c , SIZE OF LEACHING FACILITY REGULATIONS. LEACH P I r REOU I RED:_-3-3d___ G. f'. D. P 3. ALL SEPTIC SYSTEM COMPONENTS LOCATED PROFILE : NOT TO SCAL.f_� DESIGN PERC RATE _ A_ MIN/INCH . ; -VISIONS: UNDER PAVEMENT SHALL BE DESIGNED TO PROVIDED: CP .'PIT(S) W/ 3 'STN. NO, DA T E REVISION WITHSTAND H-20 LOADING. . Z SIDEWALL: -� S. F. X GPD , 4. ALL SEWER PIPE SHALL BE SCHEDULE 40 BOTTOM: 1 1 S. F. X GPD OR APPROVED EQUAL. 4 _ ?°I_ G)�_y GPD TOTAL ., 5, F. '> --__—_ - 5 5. BEFORE CONSTRUCTION CALL "DIG-SAFE" � � y,�s, ,. , P,"UL �. 1 PAUL I ' li. SD l L T _S I l' l T DATA r � is 1-800-322-4844 FOR LOCATION OF MIC a2A I DI 7 INDICATES c res _. UNDERGROUND UTILITIES. cwiL �,y c N A �" w4 PERCOLATION _ OBSERVED S41, T 6��� r y )EST _ GROUNDWATER 6. VERTICAL DATUM IS; As Stake sr vy r ' 7. BENCH MARK USED; 1 I rP•�L __-__ ;�r ._ ESSIONAL E INEER, (Cl VI -Pq SS NA LA (SURVEYOR ,o. t GRND EL. GRNU E L.I_Q�._3_ 8. FOR BENCH MARKS SET SEE SITE PLAN, G. W. EL. ►0_t)g_C_ c. W. EL.JAPN-t- 9 �.59 • _ _ 4- S1TL la L.o(_�T. t—&> iM AN` J�P -Z0kAf_. YOV50i - Yap9o%L DA TE DA TE g.M. Xi/ _ w .rOP OF CONG'l T ' 6WNCI S u i 5v 60)t~M votA ja .LEGEND ---- 50 EXISTING CONTOUR ► r. TP..1 o , N w✓a , p� ,•Z2 � - - _ -_ - � , �' l `� ' DATE, � PROPOSED CONTOUR J b�l ,N1t ,NxPRa f. 11�z I TEST C B Y - -� ' w WITNESSED 1 IN1 50 = PROPOSED SPOT GRADE i TP-2 d ' C1 -�• _ DIRECTION OF STORWA TER PERc RATE .. __ :_ rIN/INCH RUNOFF O PRo p m p' 1000 IQ 71 DIA Top vac • IL V PLAN SHOW.TNG THE DESIGN OF A PROPOSED -� • SUBSURFACE SEPTIC' DISPOSAL SYSMV LOT 95, STURBRIDGE DRIVE, BARNSTARL , MA SEPTEMBER 23, 1992 SCALE .f " = 20 ' LOT 95 EAGLE SURVEYING cg ENGINEERING INC. soo• 0 1 030* .F. 441 ROUTE 130, SANDWICH, HA ..� PROJECT NUMBER 92-119 - - �,r•e:'YiOK:.":�Yii^. NJIi•C"" K.�., » YA:.it.f 'Nts..a'rvYf4i.oKlYNO, •«.«•••,.a.:uYOBa...:Yrt' vc+e.vs,N:•Cu; --� •raof.,..,..z.. - «.-...�_^H... .. - r . ,...,_.. ...... ...»... .. ..n...,.-......amx....,.«.r....++vr+mw...nw..n..-+,».ww.u.:.. n..m. .+:wrv...re........«.... .._..r..„...... ..�...-..._ .:r......- .e...+r