Loading...
HomeMy WebLinkAbout0144 COTTONWOOD LANE moll -111'�'�",`i"' m 04 14 1tj , , �4 vg liif;f� "TOM­x­v 501 'ARNNF 00, ant 0401 RMT M al 1 i:A! ­h m I no lot tool AK&M� 'A 1. 1 ONEW HOW '411WRAS two �OTQR two! jou I j,' i w-I polio SY400- U 0�Ww TWA' 51� ih III r I'T i"�qo I v �­R j'?'Maps I, MM MW 09 iI, WA vmim R'NiTMEM "t Iio'�cT P"",I q'i �",'g§-�i —W m E 12, U .......... Rim it IN WHO 4, I .-NI-W _ 50111:11th v. q I.- q(T PAZ; WWWA, i"Or', 1­1 Rpm g uT j�' Ask, Im N MOM, 'j m'�'g g W, NYI; WN-a-im 11 1A. "gear x gut POP!QN- MONA 'g N'a t v' ' to who, IPI� I %A 4" -v Y. I'A vx ji K!W"7z�%;on 1 Q' W I "WUR, Ain.QW-W --j-1-Aps WWOUNMR-W MIRVIi, x _1. , ,I f on QQ MAIM, g , f4 "I".. 0, -04 El �Xi*11' lovi V. ,gg NO 'H Ji� R1 0, Sm "a rMom-mus"P SAW my I W 'j- ISM ""A'W Qq Z MOM ATWHINAh,QW-4-QI'_q IN Gg MON Opp 01,1 fly Q SO- A a WK 15 "W g'� V,10'yml'�'s'­i; 4 igi C iW"I AR , p-g'U. " i'.'& 68 t'. p N 11 __ I I TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Map C250 Parcel "I° nF B A n t I Application 00 Health Division :; TABLE Date Issued Conservation Division Application Fee, Planning Dept. Permit Fee . qb Date Definitive Plan Approved by Planning Board ,;Y Historic - OKH do Preservation/ Hyannis ff(? Project Street Address (2e �wocxl L4_nc Village Ct-1 e� \) L _ A(� / Owner i�tl c ;-4 ark J r• Aforcc1 C. 4d46ddress J�f y �1]i� W D f Telephone s0� 1 • �,`� g U Permit Request j1 LI ar Arr=.t !Ur 2 {-�h Y` r IT a I c G� SLZ ", J x zL IL 4 ._. w Square feet: 1 st floor: existing � proposed ! 2nd floor: existing proposed _To#al n iv — Zoning District R - Flood Plain Groundwater Overlay _ -- ac. Project Valuation 1 I DD-D Construction Type '3 Lot Size Grandfathered: ❑Yes 2,No If yes, attach supporting documentation. Dwelling Type: Single Family Two Family ❑ Multi-Family (# units) Age of Existing Structure I Historic House: ❑Yes 2 ,No On Old King's Highway: ❑Yes U No Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑ Other Basement Finished Area(sq.ft.) Basement Unfinished Area (sq.ft) Number of Baths: Full: existing new _ Half: existing new Number of Bedrooms: existing _new Total Room Count (not including baths): existing news,r First Floor Room Count Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑ Other'V 4- Central Air: ❑Yes ❑ No Fireplaces: Existing f New Existing wood/coal stove: ❑Yes ❑ No Detached garage: ❑ existing ❑ new siz&rAPool: ❑ existing ❑ new sizffJ Barn: ❑ existing ❑ new size/y/ Attached garage: ❑ existing ❑ new sizqaShed: ❑ existing ❑ new sizely-Other: Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑ es No If yes, site plan review# Current Use o r cl` K- Proposed Use APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Name (i't 61.4sah Aw Telephone Number L LM53S_? Address N-t�� n License # Cs-- D61a(gn Home Improvement Contractor# Email n D� c Worker's Compensation # '� bl��IbLS-Db ALL CO TRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL EC TAKEN TO a �m G1 i f7r ! SIGNATURE DATE FOR OFFICIAL USE ONLY V, f APPLICATION# DATE ISSUED MAP/PARCEL N0. ADDRESS VILLAGE OWNER DATE OF INSPECTION: FOUNDATION A FRAME INSULATION FIREPLACE ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH FINAL GAS: ROUGH FINAL FINAL BUILDING DATE CLOSED OUT ASSOCIATION PLAN NO. r DocuSip Envelope ID:FBED6A3D-2EZ1-41318-A4D4-1E6AE61169AB SolarCitY PPA I AMENDMENT Customer Name and Address Installation Location Date' Antone Fajao Jr. 144 Cottonwood Ln 9/26/2015 144 Cottonwood Ln CENTERVIL,MA 02632 Barnstable,MA 02632 Congratulations! Your system design is complete and you are on your way to clean,:more affordable energy.Based on the information in your.System design,there are some amendments we need to make to your Power Purchase Agreement(the"PPA").The amendments are as follows: • We estimate that your System's first year annual production will be 5,459 kWh and we estimate that your average first year monthly payments will be$56.86.Over the next 20 years we estimate that your System will produce 104,142 kWh.We also confirm that your electricity rate will be$0.1250per.kWh,(i.e.electricity,rate$0:1250 and.tax rate.$0.0000). Your electricity. rate,exclusive of taxes,will never increase more than 2.90%per year. By signing below,you are agreeing to amend your PPA and you are agreeing to all of the new terms above. If you have any questions or concerns please contact your Sales Representative. Customer's Name:Antone Fajao Jr. Power Purchase Agreement Amendment Docusigmd by: Signature: %453BW-WEi421:. SolarCity Date: -,94-619015 approved Customer's Name: Signature: Signature: Lyndon Rive, CEO Date: Date: 7/29/2015 3055 Clearview Way,San Mateo,CA 94402 1 888.765.2489 I solarcity.com Power Purchase Agreement Amendment,version 2.0.1,June 25,2015 Contractor License MA HIC 168572/EL-1136MR .a Document generated on 7/29/2015 989423 r .� b OWNER AUTHORIZATION Job ID: ou Location-011u hereby authorize o co — MA U9 I MAX to"at 0"###y behalf,in all matters relative to work authorized by thlO 601 l i1ft9'pOrmit nnP11001M)*141 signed contract. Si atu o _ r: �urtp� _d �+t:•r�P::11:.X.Odf.ii�j::it.:�.. ..��»r.•i4iie:.:r:i..iIIl � C:�'S1 �r.P.•.�.�� trs�. ++'8#;•Y�'s� •V���V��irlYVtli f �:�::i•• :.s:rttta.;:.•t:..v: .,.c•.s::•f,t �r•:;x»ri'.�a,';!+' +, :j K:. 1;:3�YC:::f..+:L lC�l.wl/ •';di ii+t: 7f:.y:f rlrs F$ r•rar . i It �►aaasrnat►eitt► �ent�+�abhr Srt�jr `z' �aa�10!lluq�aiunq itu� r.a+�l 3fu�[nh a,4004* CS-108615 S2t SMWART DRIVE 4. Abin®tba MA 02361 . 0201019 ORiee orcommmer Again&Bash=Regulation HOME IMPROVEMENT CONTRACTOR t . � `� � Regiabatlon: 1�3672 TYRo'� ExpGatton 3f8flG17 Su am SOLAR CITY CORPOiiATIONI JASM PATRY 24 ST MARTIN STREEY BLD 2UM Q � lT1MBOR000K,MA01752 Uodeaeerehry t i 77te.Corllmasf Health of Massachiisedts wiDepartment of 1nt1us1rla1Acdden&. I Congrless Street,Strife 100 Boston,MA 02114--2017 wrvou►naMgav1140 Workers'Comapensstion Insuranoe A111davit:BuilderstCenb2dardEleetriclaas/Piambers. TO BE FILED WITH THE PEWITfING AUTHORITY. . AnthltcantInfarhhhation Plea;te Prluai.Lealblt+ NktriE(l incsslUrgesyizzlinnlE»dididua>). SotarCity Corporation Address: SO%Ckwp iew Way City/Statc/Zip: San Mateo,CA 94402 Phone#. (688)765-2489 Are roe=empk .e►eye&the xp prepriae box: Type of project(recpEfred): I.WI am a anfty m 12,500 employees(fa11=dlwr' .umq}.= Q � ' .7: ❑New construction I den a sole proprietor or partmwAip and bake so employm►worl:ims for in' 9. 0 Remodoiing any t uacity.M rrmkm'comp.inswanz tequaad.j 3.ameowoerdai sdC awo*ers' dastlfwm 9. Demolition 1amaha rE.all work�' � ���,i rsalalrcdl r II 4.[]lamahnwomwrmd will behH*wnhectorslo condo all wo*onmypt+opcq. l will_ IflQBuildingaddition aware fhat ell¢vemmrs oidw have wurkm.'compammUan insuamco or ate We 11.[3 Ele ch ieal tq&irs of tiddltlolls- proiuietars wUh no anploycis 12.Q Plumbing repairs or additiotls so I mn a Scram omumtor mid I have hired the ors listed an dm atta w sheet These wb•cosi�daw here emptoy�xs and have wwkas'carte.iritauiiaae# I3.[]Roof repairs 6.E]We are a corporation and its offimm have mmbad their right of exwoInim per MGLc. 14. Other S�r pa ee% 15Z§I(41 and we hm soemooyees.jNo ivoi ,mt v.ias ragnired:J. #Any%V11 eon tlist chocks box 91 mast also All oadesectiou below showing ilmir waka V conewmion policy i Nwedon: *l[ores♦Cho"boli lhis affidavit atdie tie dory arc toms all wort{and Om hire outside corawm mtin 21061it a 11r tillid"it bads sands. tint 4mak this box moist apochedan ar kimtei sheet dva*die see of dm stib-eoramdors mid store whedw ar fiat those eatilres have effoloyces. Vik 2640rsmuxon have employars,they ors t vide their wdikcc;'oomq pohw tarinWr. . am aft emptoyw fiat is pr1:'vPoImg workers'co►npensatton insuraneefor my empdopees. Selo°w is the paltry and jab ate dafaro� Insurance Competty Name:Arnadcan Zurich Insurance Company Policy#or Mf-ins.Lie.4: WC0182015-M, Expiration Date: 91112U18 144 Cottonwood Road Centerville,,MA 02632 ' Job Site Address: City/Statw2ip:. . Attach s copy of fire werkears'ca mpeasatian pow d icebration page(showig the policy an tuber find expirafEon date} . Failure to suite coverage as required under MGL c.152,§25A is a criminal,violation punisimble by fine up to$1,500.00 anddor one-year imprisonment,a9 wd l as civil penalties in the form ofa STOP WORK ORDER and a fine of up to S250.00 a . day againstibe violator.A copy oftbis statement may be forwarded to the Office oflnvestigations tsrthe DIA for insurance covemSe velriflcation. I do kereby cer' auger the pairs end penalties of',perjury Mar rice btrormadon provided above Is hue and correct, (Jason Pa September 28,2015 Phime t7,&tad use only. Do not write in skis urea,ra be completed by.LAP or town o,#WaL . City or Town: PermitfUcense# Issuing Apthority(circle one): 1.Board of Health 2.Building Department 3.C'styfrown Clerk 4.gleetrical Inspector S.Plumbing Inspector 6.Other Contact Person.• Phone#-i • I DATE(MUMDhYM' CERTIFICATE 4F LIABILITY INSURANCE D&170015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS " CERTIFICATE DOES NOT AFFIRMATWELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE"ISSUING INSURER(S), AUT'HORIZEb REPRESENTATI E OR PRODUCER,AND THE CERTIFICATE HOLDER, IMPORTANT: If the certificate holder Is an ADDITN3NAL INSURED,the policy(Ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and eonditlons of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder In Hsu of such endorsement(s}. PRODUCER .. CONTACT . . . - . . MARSH IR C&INSURANCE SERVICES AIle PHONE 346 CALFORNIA STREET,SUITE 1300 _ ._. . . ._............. .. CALIFORNIA LICENSE NO.0437153 E4AAIL SANFRANCISCO,CA 94104 APRR4 :........ .._...._..._._'--•.-_..-- - _ AW Shww Sc*K05-743.8334 M3.UR.ER(S).WgRDIN9 coVERAeE....• - ..__:_.- . . rulc>r . 9M1-STND-GAWUE-15-16 INSURER A:Zur ompany tdl American Insuia ce C 116535 — - -_.. ..__—__ ..._.._.._. INSURER La NIA WA...... _ 3m Clean4ew way INSURER c PNA u — San tJlelso,GA 94402. .. --'• ---- ---..- .___..... .. _... ........ _.:_..-.,--._. INSURER D..Amencm ZWch Insurance Company tt0142 INSURER E - - INSURER F: " COVERAGES CERTIFICATE NUMBER: SEA•fl027t$0-08 REVISION NUMBM4 THIS 1S TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTVNTHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO VVHICH THS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN;THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO"ALL'THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAN T _ -- — INSR�_ ADtiL go. POLICY NUMBER POLICY EFF POLICY EKP LIMITS TYPE OP INSURIWCE . . A X 'C_OMMEMMI-GENERAL L AMM GLOD1820164)0 ON112016 INIM12016 EACH OCCURRENCE S _ 3.DAMAGE TO 000,000 ED CLAIb16 btADE n OUR PREM1IIRE$iETn!a ].. S 3,00D,0D0 I. —- - X SIIx MODD 6 UFO EXP(anY mlePersa}l FFRSONAL 14 3,000,000 GENL AGGREGATE LIMIT APPLIES PER: '..«F .. . . . . - GENERALAGOREGATE T S 6ADO00 rr �� X POLICY I. JECT ..'LOG PRUDUGTS:GOEAP/pPAGG S -- 6.000,000 PR OTHER. I A AuTemomUeLULsasTY PAP01=17.OD OW1015 . ODMI/2016 COMBINEDSNGLs LIMIT s J -•---•---- 5,000,000 X AWYAU70 i I 90MYINJURY(per Perwfi) S ALL SCHEDULED AUTOS X AUTOS . . I: ! k MDILY INJURY leer aawe"o S........-.. X HIRED AUTOS X... AUTOS1 I 1 P —�DA6IA—GE S _..-. .._ CO) CCU DM: 6 0 $5,000 UMBRELLA L1A8 LAA U i f -. . EACH OCCURRENCE 5 ' EXCESS UAB :. . CWAtS-0AADE J AGGREGATE.. . . —......_ s DEB RETENTIONS - "s D WORKERSCOMPENSATION ; iVYCM$201440(AO5) U91D111D15. 1WJ01f1D16 X.II PER oTH. ANDEMPLOYERB'LIAIRL.rTY _.1STl1T --- 0T _ A ANY PRdpR1ETOWPAR19dF1ilEXECUTnIE YlN a%W82015-W(MA) 09M111015' .09;D1f2016 ELEgcnacd Nr s 1,600000_ (WICERAMNSEREXCLUDEr" NIA, —._ _... PMendetoiy In NMI 1NC DEDUCTIBLE:5500,000 ` E 1.DlsEASE.EA EMPLOYEA s 1,000000 " 6 N a dasaibe W:der N TIONS E.L"DISEASE-POUCYumrr s " t i DESCRIPTION OF OPERATIONS I IACATIONS I V84CILES WA IM iBr;AdOft W Remarks Sehodmie,n*be etlachod B m m apace Is ravan dl Evldalceofklsurante. .. CERTIFICATE HOLDER CANCELLATION SdaiCdY SHOULD ANY OF THE ABOVE DE8CItUM POLICIES BE CANCELLED BEFORE " 30M Clearview Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED. IN Sari Wtao,CA.99402 ACCORDANCE VATH THE POLICY PROVISIONS. AUTHORIZED REPRESEWATIvs at Marsh Rick S,Insurw=Se►vicea . I Charles Marnwlejo Q 1989 2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD(tame andiogo are.registered marks of ACORD ti Version*46.4 A-501arG ty. July 2,2015 { Project/Job#0261358 RE: CERTIFICATION LETTER Project: Jr. Residence 144 Cottonwood Ln - Barnstable, MA 02632 ; To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes= MA Res. Code, 8th Edition,ASCE 7-05,.and 2005 NDS. - Risk Category = II Wind Speed = 110 mph, Exposure Category C ' -Ground Snow Load = 30 psf - MP2: Roof DL= 8 psf, Roof LL/SL= 16.2 psf(Non-PV Areas), Roof LL/SL=8.7 psf(PV Areas) - MP3: Roof DL= 8 psf, Roof LL/SL= 21 psf(Non-PV Areas),.Roof LL/SL= 21 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss.= 0.19069 < 0.4g and Seismic Design Category(SDC) = B < D On the above referenced project;the components of the'structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res.Code,8th Edition. Please contact me with any questions or concerns regarding this.project. N OF 1WgSs9c"y Digitally signed by Humphrey o lHRE K. m HUMP KA Kariuki U STRUCTURAL cn Sincerely, NO.51933 Date:2015.07.02 22:3.0:46-04 00 4, o Q Humphrey Kariuki,P.E. ��SSosTE��G���``' Professional Engineer NAL T.,443.451.3515 email: hkariuki@gmail.com 3055 Clearview Way San Mateo,CA 94402 T(650).638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ ROC 243771,CA CaS 888104,CO EC 8041,CT HIC 0632778.OC HIC 71101486.DC HIS 71101488,HI CT-.-9770.t.9A HIC 168572,MD MFIIC 128948,A11 13VH06160600, , OR CC8 180498,PA 077343,TX TDLR 27006.DNA GCL.SOLARC'91907.0 2043 SolarCity.All nghts re.0,W, - � N 07.02.2015 Version#46.4 Structural pp,501arCit yPV System Design Software PROJECT INFORMATION &TABLE OF CONTENTS F Project Name: . , Jr.,Residence _ AHJ: 14ar, Barnstable.,: Job Number: 0261358 Bwlding Code: MA Res Code,8th Edition Customer_Name: JF,Antone_Fajao Based On: IRC"�009,./,IBC 2009_. Address: 144 Cottonwood Ln ASCE Code: ASCE 7-05 City/State: Barnstable, MA Risk Category_ II Zip Code 02632 Upgrades Req d? No_ Latitude)Longitude. � 41 6i2543 70.322141 _ Stamp Req'd� Yes` " SC Office: Cape Cod PV Designer: Cliff Williams Certification Letter 1 Project Information,Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 i Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.19069 < 0.4g and Seismic Design Category(SDQ = B < D 1/2-MILE VICINITY MAP Lewis Island Huckins Neck A Gooseberry L--- 4" Islan• 144 Cottonwood Ln,Barnstable,MA 02632 Latitude:41.672543,Longitude:-70.322141,Exposure Category:C STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK MP2 `Member Properties Summary MP2 Horizontal Member Spans Rafter Pro erties Overhang Actual W 1.50 RoofSystem.Properties 4 + San 1 "4" 11175 ft,'"° "' Actual D 0 h7:25" ` Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofing Material .,.Com Roof.1, Span 3 Y , ¢, ,.m 'ti A :,, 10.88 in.^2 Re-Roof No Span 4 . S, 13.14 in.A3 P ood Sheathing Yes r ' San 5 Ix 47.63 in.A4. Board Sheathing None Total Span 11.75 ft TL DefPn Limit 120 Vaulted Ceiling _�� - PV It Start 1.17 ft. Woo cie 'S k d Species s PF " Ceiling Finish 1/2"Gypsum Board PV 1 End 8.33 ft Wood Grade #2 Rafter Slope 450 -a PV 2 Start ,,. k Fb 875 psi Rafters Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start" A 'E 1400000 psi Bot Lat Bracing At Supports PV 3 End.. Emi„ 510000 psi Member Loading mary Roof Pitch 12 12 Initial Pitch'Adjust Non-PV Areas PV Areas Roof Dead Load DL 8.0 psf x 1.41 11.3 psf 11.3 psf PV Dead Load PV-DL 3.0 psf T ­x. 1.41 ., m, ,,_ 4.2 psf Roof Live Load RLL 20.0 psf x 0.60 12.0 psf Live/Snow Load. .. T' .. ,' t* LL Sl."? ft 30.0 sf,�;F ` ,x,0.5C] x 0.29, w�#-16.2 psf m , `$'8.7, sf „,. Total Load(Gov;rning LC TL 1 27.5 psf 1 24.3 sf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(CO(IS)py; Ce=0,9,q=1.1;IS=1.0 Member Design Summary(per NDS Governing Load Comb CD CL. + CL CF Cr D+ S 1.15 1.00 1 0.37 1 1.2 1 1.15 Member Anal sis Results Summary Maximum Max Demand ' @ Location Capacity DCR Load Combo Shear Stress 18 psi 11.8 ft. 155 psi 0.11 D+S Bending + Stress ; 523'psi 11, 5.9 ft. °` " 1389 psi w0.38 D+S ,Bending(-)Stress 0 psi -513 psi - 0.00 D+S Total Load Deflection.. HI: . ?0:43 in.-'] 466 5.9 ft. _ 1.66 in:, 120 r0.26 . . i D+S.: - - r. FCALCULATION OF DESIGN WIND LOADS MP2 Mounting Plane Information Roofing Material - . Comp Roof Pw . o la 2 n�:V'Sys . ype Spanning Vents No Standoff Attachment Hardware Comp Mount Tyne C Roof Slope 645 1 �O. Framing Type Direction Y-Y Rafters Purlin$pacing- �� X-X Purlins Only NA Tile Reveal Tile Roofs Only . NA Tile Attachment System� � Tile,Roofs_Only Standin Seam/Trap Seam/Trap SDacinq Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method ] ,Partially/Fully Enclosed,Method ?$ Basic Wind Speed V. 110 mph Fig. 6-1 Exposure Catego_ry — Roof Style - Gable Roof Fig.6-11B/C/D 14A/B MeanMean Roof Hei'ht r . . .. °i ,. .h ,,, ',- . 5.ft� .,z a r ,4,~,—Section Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor _ '; Krt.'_ '" -r 1.00 "� Section 6.5.7_ Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor. ;;x:. .,,:,... I u•r•, . 1.0 Table 6-1-1 Im Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(V^2)(I)24.9sf Equation 6-15 Wind Pressure Ext. Pressure Coefficient U GC � -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC , wjpon). 0.87 Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(GC ) Equation 6-22 Wind Pressure U U 23.6 psf Wind Pressure Down 21.8 psf ;AL OL WABLE STANDOFF SPACINGS X-Direction Y-Direction. Max Allowable Standoff Spacing Landscape 64" 39 Max Allowable Cantilever _,___Landscape Standoff Confi uration Landscape Staggered Max'Standoff-Tributa Area P - Trib • i s" ' 17 sf ;1 PV Assembly Dead Load W-PV 3.0 psf Net Wind;Uplift at_Standoff - _T�actual��� Uplift Capacity of Standoff T-allow 500 Ibs _ v St ndoff Demand Ca aci�. rs��:;,7 7A7T4DCR. s«7& 7777VT � k3�u; X-Direction Y-Direction Max Allowable Standoff Spacing _ Portrait 48" _ 66" Max Allowable Cantilever_-_ Portrait _ 17" -_�_ NA- Standoff Configuration Portrait Staggered Max Standoff;Tributary Area _, ", Trib"� =-' 22 sf PV Assembly Dead Load W-PV 3.0 psf _ Net Wind Up U lift at Standoff_ T-actual -490 Itis _ p_---_-- -_ _ J _—_-- _ __._.w Uplift Capacity of Standoff T-allowY 500 lbs --,. -. Standoff Demand Ca aci -i7 ^�V. DCR 4 STRUCTURE ANALYSIS -LOADING SUMMARY AND MEMBER CHECK MP3 Member Properties Summary MP3 Horizontal Member Spans Rafter Pro erties Overhang 0.66 ft Actual W 1.501, Roof System Properties _S an i 12.56 ft Actual D 7.25" Number of Spans(w/o Overhang) 1 San 2. Nominal Yes Roofing Material Comp Roof S an'3 A 10.88 in.^2 Re-Roof No Span 4 S. 13.14 in.^3 Plywood Sheathing `. Yes °Span 5 .' ' I > , s '47:63 in.^4 Board Sheathing None Total Span 13.22 ft TL DON Limit 120 Vaulted Ceiling a _.r:. r: No :' PVa'Start wu C. 0.75 ft+, Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 9.00 ft Wood Grade. #2 Rafter Sloe 200 .'� . t ""; P.V,2'Start r s. �.. 1 Fe h .�.p� ...w; 875 Si Rafter Spacing 16"O.C. PV 2 End If 1 135 psi Top Lat Bracing t.. Full PV 3 Start 1400000 psi Bot Lat Bracing At Supports PV 3 End - Imi„ 510000 psi Member Loading mary Roof Pitch 5 12_ Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 8.0 psf x 1.06 8.5 psf 8.5 psf PV Dead Load PV-DL 3.0 psf, x 1.06 3.2 psf Roof Live Load RLL 20.0 psf x 0.98 19.5 psf Live/Snow Load a LL SL1,2 30.0 sf _,F:_ x 0.7 1 x 0.7 21.0_psf E'c 21.0 psf Total Load(Governing LC TL 29.5 psf 32.7 Sf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2) 2. pf=0.7(CJ(Q.(Is)p9; Ce=0.9,Ct=1.1,Is=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CIF Cr D+S 1.15 1.00 1 0.46 1.2 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Load Combo Shear Stress 35 psi 0.7 ft. 155 psi 0.23 D+S Bending + Stress 764 psi 6.9 ft:"L 1389 psi. µ 0.55 D+ S Wending - Stress -9 psi 0.7 ft. -633 psi 0.01 D+S Total Load Deflection t, r ,x:a.: "0.4 in.. . L 399 6.9'ft: .E - 1.34 in. I' ' 120 t, I �z•=:W'�'0.30 D.+S [CALCULATION_OF ESIGN WIND LOADS MP3 --_ Mounting Plane Information Roofing Material Comp Roof . x � SolarCi �.� . Spanning Vents No Stand ff Attachment Hardware ^� ° �+r " � ��' ..w ' Comp•:Mount Type C,.i��r $ �.a ., .,6i�>�3 '" � ������ Roof Slope 200 Rafter;S acin,, xk MEMO= .Rp<, 16' OC ""` .x °_' "" 22- " Framing Type Direction. Y-Y Rafters Purlin,Spacing"=' a;s Ia€ " X-X;,Purlins_Only .. " 3ru, . 'i�IVA,. Tile Reveal Tile Roofs Only. NA .m.._ „�,.,a�e,.,�eu -�w,.-. -w �y"4�°'" -' -' •-^ lea Tile Attachment S stems ' Tile Roofs On :`, .r_ _ �NA'. � Standin Searn/Trap Spacing SM Seam Only NA Wind Design,Criterui Wind Design Code ASCE 7 05 Wind Design Method � 3 n - r �.r k �,°, ._ E - ,,�. „ r . , � Partially/Fully Enclosed Method 1 ;. 4i� a � Basic Wind Speed V 110 mph . Fig. 6 1 ExposiireaCategory,;�� ;�;�xr& ~° ��� � 5 ��� as��� �:: -,s'�.�,�'�.�� � � R =����Section 6 5.6:3 Roof Style Gable Roof Fig.6-11B/C/D 14A/B Mean Roof:Hei ht;-. ,,c�. !NO 9" ��Section 6.FORK� Wind Pressure Calculation Coefficients _ Wind Pressure Exposure KZ 0 95 Table 6 3 —_p_, g, P-- .� - . - ,� K '` , _• , € UO.. r . " ° ' Section 6 5 7 A 3`0 o ra hic Factor. " �� �•;° f � .,w rt- Wind Directionality.Factor Kd 0.85 Table 6-4 y�M� ._ �a ifs t�S dx#Y aq+ f m rs .s-,�� " w$-a rl ' e r a� �F �`3°°rv' 7y FIII _"'_pw-671�„ Im ortance Factor. �.. � .,o .r �Iv _� r ., sE "3� �5 ,� 1 0 �<" la ,� 3w ;; �Table 6 1.���,,. qh =0.00256.(Kz)(Kzt)(Kd)(VA2)(I) Velocity Pressure 4h 24.9 sf Equation 6-15 Wind Pressure Ext..Pressure Coefficient U GC -0.87 Fig.6-11B/C/D-14A/B x_•,=; 1% .s. Fig.6-116/C/D=14A/B Design Wind Pressure p p qh(GC) Equation 6-22 Wind Pressure Up— 21.8 psf . Wind Pressure Down . 11.2 psf. „ ALLOWABLE STANDOFF-SPA CINGS l X=Direction Y-Direction. Max Allowable Standoff Spacing Landscape AA,. 39" MaxWlovvable Cantilever Wed Landscape °• 24"- a it i tea," NA Standoff Confi uration. Landscape Staggered - Max Standoff TflbUtd Area.3-_ i TCIb,*" r2MY, PV Assembly Dead,Load W-PV 3.0 psf Net Wind;Uplift at Standoff__ '. � ='Tactual E, 351 Itss =fig MIMIII w .: ,. Uplift Capacity of Standoff T allow 500 Ibs St-'" o e and'Ca aci 1 "a o ff . X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 4811 66" Max Allowable Cantilever Portrait ;: ...:.rn ME19 �;�°°� � s' F��� :NA��°'� x Standoff Configuration Portrait Staggered Max'Standoff Tributa "Area �_ Trib° a "` " " _.., xi ry. ._... k "�.. 4& .. .,.,. $, '' .."_ 'fe"22$f 3:a .s. '.sr tF a r `'.... 5.63e 8 � PV Assembly Dead Load W-PV 3.0 psf -.��. ..�,ar"�.�, ,Fk- s a� . � ,roe•. � +; ,� Net,Wind:Uplift at_Standoff "Tactual .° {, .�," ." "' 440 Ibsl .. ,. Uplift Capacity of Standoff T allow 500 Ibs _ 'a �-wmi :e-n 'T°` x � $'� -71 Standoff;Demand Ca aci �t;�.�,� �. .� �.�fi. D ��" Assessor's office(1st Floor): Assessor's map and lot number a , 6 SEPTIC SYSTEM WWST BE Board of Health(3rd floor): , INSTALLED IN COMPLIANCE Sewage Permit number WITH TITLE 5 ' Engineering Department(3rd floor): ENVIRONMENTAL CODE AND Dsas97SDLL � clue House number TOWN REGULATIONS i639. Definitive Plan Approved by Planning Board I 19 APPLICATIONS PROCESSED 8:30-9:30 A.M.and 1:00-2:00 P.M.only f TOWN - OF ' BA�RNSTABLE BUILDINGINSPECTOR APPLICATION FOR PERMIT TO l) \ ) H )9-4 e— R rn � 0 TYPE OF CONSTRUCTION 00 19 TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: Location G 4�1 a�\W 00 C�, Proposed Use Zoning District Fire District Name of Owner&,\N ON--N. - Address \ �T� vJ OCO \NgA Name of Builder e R \ �A 4- Address 35 �.� °0 `^`, � \� �4- Name of Architect ��� �`��— Address Number of Rooms Foundation \O ous�� Exterior ��`���\�� Roofing Floors U-3 0A G Interior Heating REPlumbing Fireplace Approximate Cost 11�L "I. d Area Diagram of Lot and Building with Dimensions Fee ��� a � pa I y 01 �5 OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regardinrthe ove c nstru ion. r Name'. < � Construction Supervisor's License FAJAO, ANTHONY f' ' �3'4270 Build Addition & Garage y, u�o Permit For g Single Family Dwelling Location 144, Cottonwood Circle Centerville Owner Anthony Fal ao Type of•Eonstruction Frame Plot ` _ Lot 4 Permit Granted• April 16, 19 9 i - Date of Inspection J ► 19 Date Completed l 19fri - r z s, M '�T a • f ! • 1 - � r•rr..��_..r7 �r#+`^h.+y.�r�r;.419'tisw.nxxxh,� .n' `h. R{` v:yy ''�;,�" ,. i ..y.If•.y^Af9c #r.r. f S� � "�.'` )^ '"'Mra h ,�r{f"%,..ty,•r+�u.^�'1'''tr�4�'':.`x`r `+•�_.:�e ^r 1.,..�,�.,,.��t,li'ts.r+-, ,.xn^.a•:.ur,'°yf,j.w^�°>d-r;}'+ymaay„_t��. Assessor's office(1st Floor): AssessoR's map and lot number as c ►� - QTHf tp`♦ Board of Health(3rd floor). e� w Sewage Permit number t DAHd9TODLL i Engineering Department(3rd floor): y rua House number �T f .�2/.i. °o 1639. Definitive Plan Approved by Planning Board - 19 APPLICATIONS PROCESSED 8:30-9:30 A.M.and 1:00-2:00 P.M.only a TOWN " OF BAIRNSTABLE BUILDING INSPECTOR APPLICATION FOR PERMIT TO y 1� e� � 'F� M\� 0 O TYPE OF CONSTRUCTION W OO l 19 TO THE INSPECTOR OF BUILDINGS: 4 The undersigned hereby applies for a permit according to the following information: Location Proposed Use Zoning District Fire District t x Name of Owner t \"A, o o Pc Address \L co�Ao W 6 A. Name of Builder e R _ .Ft A Address5 4 Name of Architect �� r� Address Number of Rooms *oundation \CUf ID0c 0��� Exterior W S `������e�S Roofing 1�!S (l Y Floors ©� 'C G : Interior l5-� �" Heating 'V \A a d ~Plumbing eC3 gY _ Fireplace. r—�C7 -- Approximate Cost °1 ,Q o (` Area ° ,' 5 C Diagram of Lot and Building with Dimensions Fee 100,5`� r i a'A 5 � 0 - - Dy r OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the ove nstru�tion. t Name Construction Supervisor's License - 1 FAJAO, ANTHONY A=252-146 N 3.4270 permit For Build Addition & Garage Single Family Dwelling Location 144 Cottonwood Circle Centerville Owner. Anthony Faj ao Type of Construction Frame Plot Lot Permit Granted April 16, 19 91 Date of Inspection 19 Date Completed 19 PERMIT COMPLETED ; spruce_ . vs wlc coy"�lywoo� �X\0sCG L3oX �X�o 1r"0d. �y00, FG . ........ - �� \ `1` �Qourcd, <\A p I i j' AHoC. Cese-71 vv & s p�o�ose� A�,��.ati 77 ) i i , LH , 1�4 A Ptj C-;e, � n V _ T T r L .-r_r LA � Assessor's office(1st Floor):� s Assessor's map and lot number Conservation(4th Floor): r —'—� Sy�� 13 w —Board of Health(3rd floor): i `70 ' Sewage Permit number t s�sr�nit: �p� �,pq w� r r Engineering Department(3rd floor: ; / o•�- @ ff! VAI3 LE'a 'm CON House number Definitive Plan Approved by Planning Board 19 "�°�-Lr APPLICATIONS PROCESSED 8:30-9:30 A.M.and 1'00-2:60 P.M.only JJ TOW1111 ` OF BARNSTA�BLE a - :BUILAtNG INSPECTOR APPLICATION FOR PERMIT TO ��j�//�o�J TYPE OF CONSTRUCTION _ � � `S• �p 7�� ,_�//��)� i E ; C 19 TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: Location C �27�er�//l� �� - -2 3 �• Proposed Use u Zoning District v Fire District Name of Owner Address' Name of Builder Address fs 3 S�oy� -��iin< ,mil//Cr✓ �i� Name of Architect Address Number of Rooms Foundation Exterior Roofing Floors /'y e��� ! _7C_<K hE 17e /Interior Heating Plumbing �2�c Fireplace Approximate Cost Area Diagram of Lot and Building with Dimensions Fee ©. �G NX OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Namei�i�/�S Construction Si ipervisor's License GAJAO, TONY r No =-�^-15-2­ Permit For BUILD DECK Single Family Dwelling Location 144 Cottonwood Lane ' 'y • r _ 1 Centerville Owner- Tony Gaj ao .Type of Construction Frame ` Plot Lot Permit Granted September 9 19 93 Date of Inspection: } Frame 1.9 Insulation 19 Fireplace 19 Date Completed ( �'$2 19 y r 1 ' 1 a Brockway-Smith Company Andersen- Brosco Architectural Group Wiindowallsa Serving Greater Northeast Architects since 1890 GARRY J. PREVEDINI W Office�and EzhibitArea: � `ARCHITECTURAL REPRESENTATIVE 146 DASCOMB ROAD (Route 93-Exit 42) 800-225-791 2 -e=em ANDOVER,MA 01810 4=4.: U FAX (24 hours) 800-242-4533 COMMERCIAL - RESIDENTIAL DATE JOB _ - I i nTit _ A IX tt .. it I I )� v � x ) � i ,ter � �•� � jj ` , , f I _ l _5 i :CI.U.QI.Q�1_e to ser_uey_or� w,tf _ uo�9e1 J r_ices, Otll 17e1Q11n9 ano rn c�p..e..c_ rilin f i 1 1 s I 1 6 �_in.,_1 I 1 1 ,9 , 1 — I t 1 1 ENTRY DOOR SYSTEM Andersen "Rain Sensitized" Iu Wood and Steel _ " 'Automatic Closing: Hinged French Patio Doors ROOF WINDOWS Brockway-Smith Company Andefsm Brosco Architectural Group WindowalW Serving Greater Northeast Architects since 1890 W GARRY J. PREVEDINI �P Office and Exhibit Area: ARCHITECTURAL REPRESENTATIVE 146 DASCOMB ROAD (Route 93-Exit 42) - 800-225-791 2 ANDOVER,MA 01810 FAX (24 hours) 800-242-4533 7 ✓�� COMMERCIAL - RESID NTI DATE JOB i ! � ( 7L Xf E t i I � .L...»... _...� F { r� f t� _ ar i1l5fe fo er_u _ou_rr�if uo�_e _J rrce.r �in.o6ow elailn. 1 . Ilk _ ENTRY DOOR SYSTEM _ Andersen "' `ain Sensitized" Wood and Steel _ 7-Automat Closing Hinged French Patio Doors ROOF WIDOWS COMMONWEALTH i DEPARTMENT OF PUBLIC SAFETY r� lug OF 1010 COMMONWEALTH AVE. 1 BOSTON,MA 02215 &8. MASSACHUSETTS CAUTION Iry _I j EXPIRATION DATE 7% ;1./a.`. FOR PROTECTION AGAINST t ! EFFECTIVE DATE UC-NO. THEFT, PUT RIGHT THUMB C ,;,.; c i'S `7'=' PRINT IN APPROPRIATE i. RESTRICTIONS ;::;;'t i , i' a.'i "T BOX ON LICENSE. j � 1 Ao t=;a:l:::I I IR1) F' H1 il..I::11=N i BLASTING OPERATORS ...... . ,I :I,: ► i'; I31:I X 1:30 MUST INCLUDE PHOTO. 11 = o:I. 1 ._. .. .. ;,J hlYFll�lnl J:: ;F--i IRT h'IA t:i ./_.7. ` I PHOTO(BLASTING OPR ONLY) FEE: NOT VALID UNTIL SIGNED BY LICENSEE AND OFFICIALLY , II I STAMPED-OR-SIGNATURE OF THE OOMMISSIONER HEIGHT: S DOB: 7 � � ,•r « SIGN NAME IN FULL ABOVE SIGNATURE LINE I THIS DOCUMENT MUST BE SIGN URE OF LICENSEE fs', ! CARRIED ON THE PERSON OF p!! y THE HOLDER WHEN.:EN- p�pM `/�t OTHERS-RIGHT THUMB PRINT GAGED IN THIS OCCUPATION. 9/4 L/O»vlltOlul�E[Il�O�✓� Ie[IJCCIJ �\ HOME :`TF,,,OVEHENT CONTRACTOR Registration 111090 'yp2 EA Expiration 11/25/94 • i 10LD Ell I ENTERPRISES RICHARD P. HOLDEN 1283 SHOOT FLYING HILL RD ADMINISTRATORr- T; • C «:, f5� M i ' ,� Q Assessor's map and lot number .. .............................. .,�... �-. - � - uFtHeTo v�age Permit number .......:..... LE,H � C .............. ... pR A RNSTA D MAGIL use number ;....... :.....- 039. +•►\0� _ 0 m f► TOWN. OF BARNSTABLE BUILDING' INSPECTOR APPLICATION FOR PERMIT TO ...:....... :" ,.a!t�' !a' ..SPIKkne,A!:.. 4� ....px.v r' ' �.A,4c TYPE OF CONSTRUCTION ................G 0.e e: ......:: ... ........................ ........... ""�!�'�Y✓ ...........19.. 1 TO. THE INSPECTOR OF BUILDINGS: r The undersigned hereby applies for a permit according to the.following information: �.�/��-y� Location ............... d.: ':. ..... -r,7 �a% ! ! T ... !��,ax<g.................. ........ . fProposed Use .................. c/r " .r .,1 ° .................:...................................................................................................... Zoning District .............. . ....................................Fire District Name of Owner ... ..141.61'-.� ':......Address .. .7r„ v Name of Builder ....,��!�....,,1.`...1�/:*.,r�-.-.t-5......................Address/..y.......,...r.,�"�........,.............,.,.,.1..:...............,� Name of Architect -'7`-...�. ✓ ?Js�' �''�'...... ti ... ,..,.e:'E.....�+{-�7.................................Address ...............�... ..,.t�!......,�.:. .,.�.,�� ., .......................... Numberof Rooms ..................... ..........:. Foundation ..................................... ............. Exterior ........ ......: x ,1. ....................Roofing .........✓ :5' ?I' . '.: ........................................... Floors .................Interior ......... ........................................... Heatingf, !�.. ? �+ .. ' ................:...Plumbing ..............�.........................' .... i Fireplace ....:...............��!1�a�................................................Approximate.<Cost ............ 4�<"" Xcr?.0.............. d - ' Definitive Plan Approved by Planning Board ____ n__-----------19,t5:6. Area ........ '... ✓�l J Diagram of Lot and Building with Dimensions Fee � SUBJECT TO APPROVAL OF BOARD OF HEALTHO• 100•00 L dT /5'? /S; 4 • 4 . 4�- GAT)ON \.? 0 L Alt-1' G� •� OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction Name .................... ...................................... � ,C's-j�- Construction Supervisor's License ............................... MOORE; KENNETH E. A=252-146. No .2" 05:.:.. Permit for ....z.... �................. i f + Single Family Dwelling ....... ......... .................................................. Location Lot 159, 144 Cottonwood bane .............................................. Centerville . ............................................................................... Owner ...Keneth...E.....Moore............................... .. ........... Type of Construction Frame ` Plot ............................ Lot ................................ Permit Granted ....October 17, 84 t ...................................19 Date of Inspection ....................................19 Date Completed ......................................19 F Assessor's. ma~ and lot number . j ,� �- oT E0 U := S"—dge Permit number ........ ...! 7q 7 \'r � �1 yp pg - - SEPTIC Hclfuse number' .............. ....� e ......... t 1u A . so �� ASH9TADL MABB i639' �0 w e ' ` '°JLrO MPS M• TOWN OF B N)S I.AB'LE ... - F A W'0!'S F3 '3- 1 7210 X..A 7 ik l6 ti*j BUILDING '. INSPECTOR APPLICATION FOR PERMIT TO .........A:f;g t/.9.rVC7....A. -.4.45'... Avir l.,t k;� TYPE OF CONSTRUCTION .................��V,d. .... ; ii�YE.......... !4�...xTfe `',, ........................ .......... ...........19.. ' TO THE INSPECTOR.OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: �l Location ............... ..........Cd.jTl�a!�lt../ Al-4w.le................ . ProposedUse .................. ............................. ... ...................................................... ..................... Zoning. District ............. �..�... .k4.e ".e �� � ...... .. . ........................Fire District .�' .T.E 1. ...-' .:E.�,k'J.�L Name of .Owner ..... ......Address ..:. Name of Builder ...../.t'dao;. e..................... .........,fGI ,1r.� .- Name of Architect ....... ...................:......Address :..............Afro f.X-401 S..T ....................... Number of Rooms ........................................Foundation .............CiQ.dl Exterior ......:.C�cr`' �. -7�,,91 .....�/��C1.lrl.1G�L.�....................Roofing ........�f.�+,.�P.��.r.�........................................... Floors ............. .Y ........... .. ��.4.ole Z... . �.Q�.Jd. .... ............... ............ .Interior ......... 4i�G. .........:............................... Heating ..........1,,.tf�'.r...GG��d/ e�!P.. 1 .......::...........Plumbing ...:.:......a;................................................................. Fireplace ....................L?,,,V.,r.................................................Approximate Cost ............A''55* d.a............................ Definitive Plan Approved b Planning Board ____ ,� 19c Area pP Y g - ---------- Diagram of Lot and Building with Dimensions Fee ""3 ... ................ SUBJECT TO APPROVAL OF BOARD OF HEALTH WA* r, �d•�o �I004C 100.00 tnr _ o Oq,o OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Name ... . ..... ... Construction Supervisor's License ®vv vv�%`/G� MORE, KENNETH E. �' No U 1� S Permit for s to 71 , t ' Single Family Dwelling ....a.......... ............... .. .. .................... i" Location Lot. 159,_ 144.. ... Cottonwood Lane t ...... .... . .... ...... ....... Centerville `. .................... .............................................. Owner .Kenneth E. Moore............................. f, i -r' Type of Construction yam` f f . . .. .... ........................................... tPlot ? ............... Lot ................................ S October 17, 19 84 r, Permit,Granted ....... + ' Date of Inspectio .....��,!!�,1,9S, a Date completed .. f .... .. .19f_ 5 i 10 r THE FOLLOWING IS/ARE THE BEST IMAGES FROM POOR QUALITY ORIGINAL (S) IrA�C(�� mt, IL DAT A TOWN OF BARNSTABLE Permit No. _-_-_-_- Building Inspector I .k"3TAM Cash ------------------- --- - �g ,619. omit OCCUPANCY PERMIT Bond Issued to Address Wiring Inspector Inspection date Plumbing Inspector Inspection date Gas Inspector Inspection date Engineering Department Inspection date Board of Health Inspection date THIS PERMIT WILL NOT BE VALID, AND THE BUILDING SHALL NOT BE OCCUPIED UNTIL SIGNED BY THE BUILDING INSPECTOR UPON SATISFACTORY COMPLIANCE WITH TOWN REQUIREMENTS AND IN ACCORDANCE WITH SECTION 119.0 OF THE MASSACHUSETTS STATE BUILDING CODE. ....................................................... 19............ .............................................._..................._........................................... Building Inspector w � A C ' ± .. *wit` .. ., _ � , , _ y ' -(., •� &is .n �r:•.�• X v,; , �\' t :, r '�. � -t, 't .. .. ' ' • t t.i ` r �1 a .. #, tr�' AA _ d S , °' ' ' ►' '` 0` Mh` y�',r, Y��''L .[ J{` ,'yam` y,a 'r• 1F x , M1'. t'• •• 9.'4i i. •.•i«< - - . .. - m . • '1rM F.:•'% T{ ' iXl•s;. X ` t b,r'aMY' i l} i. 4„'i,�."'Y,".'f•NF F- F.. r t; �[' T •r \ « .jL� +�,f�y^,�sww-.,. 4 ,� f �y yr ; , i •r r , .` L, i �' .:q,,.,4 r. YY-n a - - ,• a • , '� •. '++�'�I'���Ef'�� -4 �'*rn5', -�7Wr'• l - • l Y , i 5 n a: ♦ • h �µ- ,y + . • -;X .� f x �•.� .. _ w,C -# L F�'.a-� •TF'+wwn►! ',y .' r^°�,` 'iy N �j".;y,•, I'M f:. �8` .F .r , (�,yJ ... . e � • Y r ;� ... ".4. � F.. {-'. �` , of � V . , -, r - e+�. .� I •, , 44 n `•r �4ta �,-, •x: �,!•��,'��p�,y,(�M }4 �`yw � Ls ! rw ,,.e�j - v J� / sX •r e ,y.�^]wg . .L,' ..i- r- r +fir ••,c . r. M. ^. * ''\•{• � j}f �� ^'N'•w..-' ....r7.• M1• -,J ..i I V F�,> a , '.! - 1/•M'" .1M"N•=wd - ee «.�e '• ..?'a- LOS .. r r' •' - t • ( L y,.Jyl. A ,4. / 1'. e, v ^ , . A •� i � a , �j r. . • 1 • r d,,,51" T�'C�'. - iC*F{1�. "�i..,. ,".. -`��,�'�- �`°"�"w ...�,:r ����' • `y i 'j�"�,.., .:�' a • , ,L• ,,, '.,,,.,.,._,... — �,.:: .y'{\a, l (,'�^..j�.7�^7'��'� �• }��jj ,��MFr�X�� ....a�e1 t .'Y� , _ „, C1�'/ ` f ., t ,d. ' - . y - 6. ��. K yF• .�Ie/• f,""6u.� 1' T .. y�r�!'••r'""'ay.F"'� r'"H 5 r ��R � �X 5 r� r "rfJr� _ •i a.o y e r, � r£�' i,"Ci ,; , V 't r ''�' ..n'1'��y�•���1�,q✓r.�,yy .p�'yy C'��r � .'k C�.'�*�#'•' 'Y .. •` �a•t� No lV05 . •• - ... � 'ti , - ; � (.f�VA:�tL�iF 4• /!' .y�y` f/� • • `F • �`•Ye XN r4• � 6Y� .•. ~�. ,•j .\ - " - Q� ,nl'Ti�X?�f04+LE� ��' �F d' K. - ` f `t ', i {y � 1 ,5i.•< S. „', L.t:r . ' �•a a.. Y _ , fit: .,. t z ,��. •.•RT �,'fi., �i r , 'r ., a« r• - •. S' .. .. - qy C�r�i S V .M' dk t J. .F, ra. , • y r r Y• , ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A �;• AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. . . . CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN - EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH.ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK. A SIGN WILL BE PROVIDED WARNING OF THE t. GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR b. EACH UNGROUNDED. CONDUCTOR OF THE GND GROUND MULTIORE BRANCH.CIRCUIT WILL BE IDENTIFIED,BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97� 250.92(B). Isc SHORT CIRCUIT CURRENT 7. - DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE. RUN IN.METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E): MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN . (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT. NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS.STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT - W WATT - 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 PROPERTY PLAN PV3 SITE PLAN PV4 STRUCTURAL VIEWS .LICENSE GENERAL NOTES P P6V UPLIFT CALCULATIONS THREE-LINE DIAGRAM ' 1. ALL WORK TO BE DONE TO THE 8TH EDITION Cutsheets Attached GEN #168572 .. ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Barnstable REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: NSTAR Electric (Boston Edison) CONFIDENTIAL— THE INFORMATION HEREIN [IN : ER: I q Q PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE v B—O 2 13 U O O BENEFIT OF ANYONE EXCEPT SOLARCITY INC., SYSTEM: JR., ANYONE FAJAO 4 JR. RESIDENCE Cliff Williams •i,01arCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Mount Type c 144 COTTONWOOD LN . . 5,72 KW._.PV ARRAY ►r PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. BARNSTABLE, MA. 02632 ORGANIZATION, EXCEPT IN CONNECTION WITH TMK OWNER: 24 St, Martin Drive,Building 2 Unit 11.. THE SALE AND USE OF THE RESPECTIVE HanWha Q—Cells # Q,PRO G4/SC 260 . SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ��' PAGE'NAME: SHEET-. REV: DATE Marlborough, MA 01752 PERMISSION OF SOLARCITY INC L (650)638-1026 F: (650)638-1029 REDGE SE5000A—USOOOSNR2 5087:717597 COVER. SHEET PV 7/2/2015 (BBB)-SOL-CITY(765-2489) rmr.soarcity.com .3. R PROPERTY PLAN 41 Scale:1" 20'-0' 0 20' 40' F s PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-0261358 00 CONTAINED SHALL NOT BE USED FOR THE JR., ANTONE FAJAO JR. RESIDENCE Cliff Williams SD�a�C�t BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �,,; NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mouth Type C 144 COTTONWOOD LN 5.72 KW PV ARRAY y. PART TO OTHERS OUTSIDE THE RECIPIENT'SORG NOODLES BARNSTABLE MA 02632 THE ASALE AND USE OF INNIZATION, EXCEPT CONNECTION RESPECTIVE�TM (22) HanWha Q-Cells # Q.PRO G4/SC 260 z4 St Martin Drive, Building 2 Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME My REV. DATE Marlborough,MA 50) 29 PERMISSION OF SOLARCITY INC. INVERTER.O508771 7597 2 7 2 2015 (88B)-8oiaTY(765-24898-1028 F.) ww solardiycomSOLAREDGE sES000A—us000sNR2 PROPERTY PLAN / / i SN OF Mgss,9 2 St o es R �. STORY:. rl � HUMPHREY K. PITCH 45 o � . MATERIAL: Comp Shingle,AY KA IUKI MP2 AZIMUTH 240 - SNo siss � PITCH: 20 -ARRAY PITCH:20.. U N 'O MP3 AZIMUTH:60 ARRAY AZIMUTH-60 R �� MATERIAL: Comp Shingle STORY..2 Stories' �.FG/STE .. . , `s`S�ONAL STAMPED &.SIG14E[i FOR STRUCTURAL. ONLY Digitally signed by ` Humphrey Kariuki Dat e: 2015.07.02 22:31:15 04'00' LEGEND P (E) UTILITY METER & WARNING LABEL <121'1Z INVERTER W/ INTEGRATED DC DISCO h� & WARNING LABELS AR E N © DISCONNECT,DC & WARNING, LAB LS FAC AC DISCONNECT & WARNING LABELS , B a _ Rr B O DC JUNCTI N/COMBINER 'BOX & LABELS • -. ZI/5 TR LABELS QD DISTRIBUTION PANEL & : ion. , l Lc LOAD CENTER & WARNING LABELS 0 O DEDICATED M AC O 0 O O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR -- '.CONDUIT: RUN -0N INTERIOR GATE F. . / ENCE 0 HEAT PRODUCING VENTS .ARE RED' �,INTERIOR: EQUIPMENT IS DASHED. SITE PLAN .. N 1/8" — V . sy - Scale: 0 1' 8' i6, :F PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER J B-0261358. 00 ,1R., ANYONE FAJAO JR.: RESIDENCE +m° CONTAINED SHALL NOT BE USED FOR THE . Cliff Williams s BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.��i NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 144. ,COTTONWOOD LN So1co. ty. Comp Mount Type C 5.7.2 KW PV ARRAY- ���. .. PART TO OTHERS OUTSIDE THE RECIPIENT'S MoOutEs BARNSTABLE MA. 02632 ORGANIZATION, EXCEPT IN CONNECTION WITH , N Drive. II Untt 11.. THE SALE AND USE OF THE RESPECTIVE (22) Hanwha Q-Cells # Q.PRO G4/SC 260 24 St Mart ' SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN PAGE NAME DATE M oroaioi;MAd01752 PERMISSION OF SOLARCITY INC. INVERTER: 508771759T SHEET:PV 3 7 2 20�5 ., T. (650)638-1028 F: (650):638-1029 SERTER: GE SESOOOA-USOOOSNR2 SITE PLAN- / / (888)—SOL-CITY(765=2489) wwwsolarcitycorn (E) 2x6 S1 4 4 S1 12'-7" (E) LBW 4' _ - „'-9' SIDE VIEW OF MP3 NTS (E) LBW SIDE VIEW OF MP2 NTs _ ', 6 MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 2411 STAGGERED LANDSCAPE 64" 1 24° STAGGERED PORTRAIT 4811 19" PORTRAY 48° 17" RAFTER 2X8(70 16"OC ROOF AZI 240 PITCH 45 ARRAY AZI 240 PITCH 45 STORIES:2 RAFTER 2X8 @ 16„ OC ROOF AZI 60 PITCH 20 STORIES: 2 CompShingle ARRAY AZI 60 PITCH 20 C.J. 2X6 @16" OC Comp Shingle • SH OF A14ssgc'S- PV MODULE g� HUMPHREY K. 5/16" BOLT WITH LOCK INSTALLATION ORDER g KARIUKI. -� & FENDER WASHERS o STRUCTURAL c LOCATE RAFTER, MARK HOLE NO.51933 -10 ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT !Ps o _ '0 HOLE. ZEP ARRAY SKIRT (6) NAl (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. STAMPED & SIGNED ZEP FLASHING C (3) (3) INSERT (LASHING. FGI� $TRUCI'URAL f3NL.Y (E) COMP. SHINGLE (4) PLACE MOUNT. Digitally signed by Humphrey (1) ' (E) ROOF DECKING (2) Kariuki: INSTALL LAG BOLT WITH Date:2015.07.02 22:31:03 5/16" DIA STAINLESS (5) C5) SEALING WASHER. -04'00' STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER G(6) BOLT & WASHERS. (2-1/T EMBED, MIN) • (E) RAFTER STANDOFF S1 Scaler 1 1/2" = 1' J B-0 2 6,13 5.8 0 0 PREMISE OWNER: DESCPoPTION: DESIGN CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: Cliff Williams � CONTAINED SHALL NOT BE USED FOR THE JR., ANTONE FAJAO JR. RESIDENCE SOIarCIt BENEFITOR OF ANIT BENE E)(C PT 1N SOLARCITY WHOL OR IN MOUNTING SYSTEM 144 .COTTONWOOD LN 'i�: PART TO OTHERS OUTSIDE�THE RECIPIENTS Comp Mount Type. C 5:72 KW PV ARRAY ORGANIZATION, EXCEPT IN CONNECTION NTH MODULES: BARN STABLE, MA 02632 THE SALE AND USE OF THE RESPECTIVE (22) HOnWho Q—Cells # Q.PRO G4/SC 260 24 St. Martin Drive,Building"2,Unit 11 SOLARCITY EQUIPMENT, W THOUT THE WRITTEN PAGE NAME SHEET: REV: DATE Madborough,MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: T: (650)638-1028 F: (650)638-1029. SOLAREDGE SE5000A—USOOOSNR2 5087717597 STRUCTURAL VIEWS PV 4 7/2/2015 (888)-SOL-CITY(765-2489) www.solarcity.com UPLIFT CALCULATIONS i ) SEE SEPARATE PACKET 'FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: I — �j �j R PREMISE OWNER: DESCRIPTION: CONTAINED SHALL NOT BE USED FOR THE "B O2"1 358 00 DESIGN: � JR., ANTONE FAJAO JR: .RESIDENCE Cliff Williams BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM larCoty,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 144 COTTONWOOD LN 5.72 KW. PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS IMODULES:- BARNSTABLE, MA 02632 ORGANIZATION, EXCEPT IN CONNECTION WITH2 St:Martin Drive,Building'2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (22) HanWha Q—Cells # Q.PRO G4/SC 260 SHEET: REV. DATE 4 Madin MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: p, PERMISSION OF SOLARCITY INC [INVEIM: SO$771.7597,'. PV 5 7 2 20�5 T: (650)638-1028-F- (650).6W--1029. SOLAREDGE sESooDA=us000sNR2 'UPLIFT CALCULATIONS / / (may-SOL-CITY(765-2�) www.sdar�>i.�, GROUND SPECS MAIN.PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO ONE (E) GROUND Panel Number: Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE #S E5000A—USOOOSNR LABEL:, A —(22)Honwha Q—Cells Q.PRO G4/SC 260 GEN #168572 ROD AND ONE (N) GROUND ROD AT Meter Number:43943652 Inverter; 5000W, 240V, 97.59a w/Unifed Disco and ZB,RGM,AFCI PV Module; 260W, 236.7W PTC, 40mm, Blk Frame, H4, ZEP, 1000V ELEC 1136 MR PANEL WITH IRREVERSIBLE CRIMP Underground Service Entrance INV 2 Voc: 37.77 Vpmax: 30.46 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 150A MAIN SERVICE PANEL E� 150A/2P MAIN CIRCUIT BREAKER (E) WIRING IflVel"t2C 1 _ CUTLER—HAMMER +DGC+AM 150A/2P Disconnect 3 SOLAREDGEUS000 MP2MP3: 1x11SE5000A-USOOOSNR2 �1(E) LOADS A --------------- ---------- ------------------ a zaav F--- --- � I - i Lz Dc. 30A/2P EGC/ Dc+ I 2 3 3) A ---- GND ----.--------------------------------- — GEC ---TN DG { MP3: 1X11 I B I - _ - i GND -- EGC--= ------------------=-- —=----------- G ------ � N i (1)Conduit Kit; 3/4'EMT c EGC/GEC. GEC i TO 120/240V i SINGLE PHASE UTILITY SERVICE is I I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN r Voc* = MAX VOC AT MIN TEMP POI (1)SIEMENS#(1 PV BACKFEED BREAKER Q (1)OUTLER-HAMMER DG221URB \, �2)SOLAREDGE 300-2NA4AZS Breaker, 30AY2P, 2 Spaces ^ Disconnect; 30A, 24OVac, Non-Fusible, NEMA 311 AC P v PowerBox ptimizer, 300W, H4, DC to DC, ZEP DC -(1)Ground Rod; 5/8'x 8'. Copper 0)CUTLER-LtAMMER R DG03ONB Ground/Neutral It 30A,,General Duty(DG) nd (1)AWG6, Solid Bare Copper -(1)Ground Rod; 5/8' x 8'. Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE RE 1 AWG #10, THWN-2, Black 2 AWG#10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC O (1)AWG g10, THWN-2, Red O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.07 ADC (1)AWG#10. THWN-2, White NEUTRAL Vmp =240 VAC Imp=21 AAC • • • (1 Conduit Kit;.3/4'.EMT s - 1 AWG THWN-2,•Green EGC GEC- 1)Conduit KN; 3 4 EMT � � .(2�AWG 0, PV Mfire, 600V;Blade �Voc* -500 �VDC Isc =15 ADC- O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.07 ADC (1)Con0uit Kit; 3/4' EMT J B-0 2 613 5 8 0 O PREMISE OWNER DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER LN N�tASolarCit CONTAINED SHALL NOT BE USED FOR THE JR., ANYONE FAJAO JR. RESIDENCE Cliff Williams BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: . �.r NOR M 1N ALL IT BE DISCLOSED IN WHOLE OR CompMount Type C 144 COTTONWOOD 5.72 KW PV ARRAY . y. PART TO OTHERS OUTSIDE THE RECIPIENTS MoouL! BARNSTABLE MA 02632 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (22) Hanwha Q—Cells # Q.PRQ G4/SC 260 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: RM. DATE Marlborough;MA 01752 PERMISSION OF SOLARgTY INC, INVERTER 1 (6,.638-1028 R (650)638-1029 SOLAREDGE SE5000A-USOOOSNR2 5087717597 THREE LINE DIAGRAM PV 6 . 7/2/2015 (686)-SOL-CITY(765-2489) www.sdarcitya«n mum Label Location: Label Location: Label Location: (C)(CB) (AC)(POI) o (DC)(INV) Per,Code: Per Code: _ _ Per.Code: NEC 690.31.G.3 ■o 0 0 0 - • ° NEC 690.17'E A. ■ o ■ e o- ' 4iJF� NEC 690.35(F). . _ ■ - o 0 0 • •- TO BE USED WHEN . Label Location: oCp:° (DC) (INV) ° c ° . ° ICJ - ° INVERTER IS Per Code: UNGROUNDED NEC�690.14.C.2 Label Location: Label Location: o 0 o e -0 a °CP.;, (POI) e (DC)(INV) Per Code:. • e _o Per Code: •-■ ■o 0 o NEC 690.17A; NEC 69.0.54 e NEC 690.53 - o- U. ;. 41Gi.I NJ Label Location:. . �n o (DC)(INV) Per Code: , �• -o ■ ■ ° NEC690.5(C) o- -o ■ ■ Label Location: o ■ o- 0 (POI) ■ -o - o - Per Code: o ■ o - NEC 690.64.6.4 d . Label Location: (DC)(CB) • ._ Per Code: Label Location: ■o 0 o e - ° NEC 690.17(4) Q (D) (POI) r. • o :o - n o 0 o M: Per Code. - �:. ° NEC 690:64:6.4 F . Label Location: o (POI) Per Code: I WELabel Location: e e NEC 690.64.B.7 AC POI o 0 0 - o T (AC): AC Disconnect ; Per Code: l�"I©o■ .- (C Conduit NEC 690.14.C.2 .,(CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect . A . . (IC): Interior Run Conduit Label Location: INV) Inverter With Integrated. egrated DC Disconnect p (AC) (POI) ) - (LC): Load Center . . CA Per Code: _ y �n- NEC 690.54 , (POI):tPointnofeInterconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ��rr�I 3055.Clearview.way IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, ����� San Mateo,CA 94402 Label Set I I T:(650)638d028-F:(650)638-1029. EXCEPT iN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE ��� 5-2q (888)-SOL-CIfY(76 89)wwwsolarcity.com SOLARCIIY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCIIY INC. oarCto 4 olarClty ®pSolar Next-Level PV Mounting Technology ^SOIarCity ®pSolar Next-Level PV Mounting Technology Components Zep System - for composition shingle roofs • `�''''-'..1�'p-roof tertwk . - Ground Zep (rep site tmami- - ti . leveifag r t 1 Co�aUbfc PV Momne , "'-- .. .. - ., - - :. _.�;.. ._. •.- :. - Zcp6roove .�-- Roof Ama hment - Array Skfrl - a�F Description L PV mounting solution for composition shingle roofs Works with all Ze Com atible Modules Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules Auto bonding UL-listed hardware creates structual and electrical bond V� LISTED Comp Mount Interlock Leveling Foot Part No.850-1345 Part No.850-1388 Part No.850-1397 Listed to UL 2582, Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 c V Designed for pitched roofs Installs in portrait and landscape orientations _ • Zep.System supports module wind uplift and snow load pressures to 50 psf per UL 1703 Wind tunnel report to ASCE 7-05 and 7-10 standards y •. Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 4Y • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely _ responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. - 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 1..of 2. - 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 2 of 2 - - - _ , ;..solar - p - solaWo - 0 SolarEdge Power Optimizer ri o w 00U/e 350'/�P400 No America M North ca A e- 3 SolarEdge Power Optimizer P300.- P3S0 P400 - Module Add-On For North /'lmerica :H - Ifor60-teIIPV (for 72-cell (for 96-cell PV _ .. modules modules) modules)_ . . mod P300 / P350 / P400 INPUT. - - .' Rated Input DC Power"�............................. .:..........300........ .. 350 ..... ....... 400 W - Absolute Maximum Input Voltage(Vocal lowest temperature) 48 - 60 - 80 Vdo MPPT Operating Range 8. 46 - 8-60 8 80Vdc ' Maximum Short Circuit Current(Isd.. ... ...... ........ ..... .10. .. ...... Adc _ .. .. rim - - Maximum DC Input Current 12.5 Adc - - - . - ............................................. .... ... ......................... .. ................ .. .. ................................................................99.5 .. %... WeiBhted.EfficiencY..... 98.g % - Overvoltage Category .. ....... .. .. .... ... ............ ....'L..:. .. .. .. ...... - ,, OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) „,� : Maxmum Outpu[Current 15 Ad..... - ....axlirn......utpu........ ....:... ....................... ..........:.........:................:.................. ... .... Maximum Output Voltage 60 Vdc . . .-. OUTPUT DURING STANDBY(POWER.OPTIMIZER DISCONNECTED.FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc . STANDARD COMPLIANCE - ., EMC FCC Part15 Class B IEC61000 6 2 IEC63000 6 3 - ........................ F ....................................................................... Safety- ... .. ..... IEC62109-1(class II safety),UL1741 ..•• .••.. - R�__..-: c RoHS........ ....... ... ...... .. ...Yes...... ....... :INSTALLATION SPECIFICATIONS -- - ,r Maximum Allowed System Voltage 1000 - ..Dimensions(W x L x H) ••. 141 x 212 x 40.5/5.55 x 8.34 x 1.59................ mm/m _ ............................. ......... ..,... ................................ ..... .... ....... .. - Wei ht lincludin cables) 950/2.1 ............................... ..:gr/Ib.... .� MC4/Amphenol/.Tyco - . .... ....onn.......................::.........................'..:..................... ..... ............................ ............. T •, : Output Wire Type/Connector................................ .. ..Double Insulated;Amphenol..................... - .............. .... ...... ..... .. .. 0.95/3.0� 12/39 m•/ft.... .. - :. _ .................... .. ...............:..'......:...........:....:................ ..........L.............:............. ............:.:...:......: ..... ...... - - Operating Temperature Range :: -40 +85/40 +185 •C/'F - .... ... .. ....................................... ......... ...... ......... ......... _ .. ... Protection Rating.............. :...............................:..... ......... .............IP65/.NEMA4..:. ....... ........ .............I. Relative Humidity............................ 0 100 ....%:.. .. VC powp.or lh,..dme.Module approsx p—.1--l—d r PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE, � -" • INVERTER. ,r... 208V 480V.. PV,power optimization at the module-level_ MinimumstringLengtnlPoweroptimizers) 8 10 1a . ....................................................... .. - Up to 25%more energy - - Maximum String Length(Power Optimizers) ............. .... .25.. ... 25•• ,., - Maximum Power per String - -5250 `6000 - 12750- W - Superiorefficiency(99.5%1 ................g........."re.n'.....�................................... ... ...... Y... ............... _ ........... . . - Parallel..... s of Different Len hs or Orientations Yes -.Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading • ""''"""" """""""""""" """`"' "". """"" """""'�"" ,� - ""' .............-- - - Flexible system design for maximum space utilization - -`may - Fast installatidn with a single bolt d. . . . . . -*-v--•-�--�f. *.w .v' "r'xi t:u: .�. pia, at... ,,t q T. .. - Next generation maintenance with module-level monitoring ' - - Module-level voltage shutdown for installer and firefighter safetyt7 USA - GERMANY ITALY - FRANCE - JAPAN.--CHINA - ISRAEL - AUSTRALIA www.SOIaredge.u5 �.;. Q�& 'moo,qt, ma ..�,.�.a. na. n mnHC a�Vymwar9lam,-�. � X solar Single Phase Inverters. for North America Ko .. O Iar e e SE3000A-0S/SE3800A-US/SE5000A-US/SE6000A-US/ soo ' 6 A-U 100 SE7 00 S/SE OOA US/SE11400A US utfi afx4,ri "¢ x*`:o .va+w�, j� ?;; /•, SE3000A-US I SE380OA-US I SESOOOA-US I SE6000A-US I SE760OA-US I SE1000OA7US SE11400A-US ,. 'r A kPy'. .OUTPUT _ - 9980 @ 208V - SO'arEd a Single Phase Inverters x: ,„s < 4 � �'ry tl. Nominal AC Power Output - 3000 3800 5000 -6000 7600 11400 VA - 9 9 �' e MfiFR't"3-°.a+L�lk t,. .......................................... ............ ........ ................. ............. ............ '10000 @240V .............. ......... � §. 5400 @ 208V - 10800 @ 209V - '�""':, Max.AC Power Output 3300 4150 6000 8350. @ 12000 VA For North Allle-riCB . ..,+, �"u.><"th,"? ''�• 41` '.`.'w':` ...............:..... ..... ..... . ........ 5450@240V ............. ........ 10950...240V .............. .. _;. .. 240 :...: . AC Output Voltage Min Nom Max. :: -. 183-208-229 Vac . . ✓ ✓ SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ ='r m .. ....... .. ......... .. .. ..... AC Output Voltage Min:Nom.-Max* $E7600A-US $E10000A-U.S/SE11400A-US }`"� ✓ r r ✓ / sa :- 211.240.264 Vac....... ..... ...... .... .... .. .... .. . ... ... ....... ..... ... '� " " x ,,, t. ,:•'- AC Frequency Min Nom.-Max.*�r - 59.3-60-60.5(with HI country setting 57-60-60.5) Hz - . . - `. �' '-= ._ .. .. ....... ........ ............... ...... 24 @ 208V ... .... ....... ...48 @ 208V.................. ......... . . Max.Continuous Output Current 12.5 16 25 32 47.5 A I::z�@.z40:.1.:..:......... :I::. . L..42 @ z4o�...... G ...... ...... ... ......... .A....... ....... .. .. ...... .. I . FDI 1 A UtilityMonitoring......ding......... ............................ ................. .... .... ................. .......... ......... a; Protection,Country Configurable Yes ... -+-+r....:. `evert Thresholds . r .-.r-- a...� "'**•,f;fin`•�D Z - ..INPUT Recommended Max.ax.DC P ow r* 3750 4750 6250 7500 9500 12400 14250 W...... . .... .. .... ........... ...f...-........... : --.-•- -a«-...-.,__-..;,,,a,. m •• Transformer less,Un rounded - Yes - \;ataen Max....l....Volta a 500. . . .. Vdc ----- - - --- 325@208V/350@240V - Vdc '`, , 'i `'< ":', ••, Max.Input Currents** ... 9.5.... ....13.... .....18... .._..23.. 33 @ 20 .....34.5.... ...Adc... .. .. .. .. ....... ... .. ....... ..... .. .. . �. -x •.a .:[r .. 115.5@240V I ( 30.5@240V I . . ,. _. _ --. ..... ....... .......... .. .............. . ...... ... .... ............. ................ ............ .... .. . .. .. Max.Input Short Circuit Current 30 45 Adc ..... _ . . .. .............. ....................................................................I................................................................._ - .. y Reverse Polarity Protection. Yes - _ ............................... ......... ......... Ground-Fault Isolation Detection 6001toSensitivity - ........................................... .. .... ......... .. .. .......... .................. .. Efficiency.....::... . . 97.7--" --"98.2 98.3 ...98.3.. 98 ..98... ... 98 ....'7... ..... : ..... .. % - .. .. ... .. . .. .,. ... i .......... ........ ..::..I.. �Y...L....... L.97 @zo oY..L.......................... .. CEC Weighted Efficiency 97 5 98 9 97.5 97 5. 97.5 % - �-� Nighttime Power Consumption <2.598 - <4 W @ 20 ADDITIONAL FEATURES @ 24 Supported Communication Interfaces - R5485,RS232,Ethernet,ZigB.ee(optional) .. ...... ...... ................ ..........Optional. ..... . ....._...................................... ......... . . • » Reven ue Grade Data,ANSI C12 1 STANDARD COMPLIANCE..... -. 4 .� .w..._- "_•. Safety.................. UL1741 UL16998,,UL1998,CSA 22 2 - �� ., ...... ............. .... .,. ..... .... .-... .. .......... ........ ......... ..... .. - • `° .:, z ,,.» ; . ; Grid Connection Standards IEEE1547 Emissions......... ... .... ... ...... .... .... ................. pCC art15 class.................. ....... ............ .... . - 1 ., ....... .. p INSTALLATION SPECIFICATIONS .. t AC output conduit size/AWG ran a 3/4 minimum/24 6 AWG 3/4"minimum/8-3 AWG - q g.. .... .................................... w,• .. p DC input conduit size/N of strings/ 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG .............. _ - Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ - 30.Sif 12.5 x 7.5/ in/ 30.Sx12.5x10.5 775x315x260 4, •.. ;,y, Switch(HxWxD).... 775 x 315 x 172 775 x 315 x 191 - - min. .. '` ,. .` ,. Wei ht with AC/DCSafetySwitch 51.2/23.2.... ""54.7/24.7.. ..88.4/40.1-- ...lb�,., •.. .. ......................I.................................. .......................................... Natural Convection. Fans(user replaceable) - . ........................................:.. .................... ...................... ........................... .. The best choice for SolarEd a enabled systems Noise ..... .... ..::5z5 .............. ........................<so............ .... .a@?:.. g Y Min.Max.Operating Temperature 13to+140/ 25to+60(CAN version••••-40to+60) F/ C - Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Range.................................. b Protection Rating. .. ................. ........... ...........NEMA 3R Superiorefficiency(98/ ............................... ........ ......... ) .. --....... ...... . •For other regional settings please contact SolarEdge support. Small,lightweight and easy to install on provided bracket - - - ••Limited to 125%for locations where the yearly average high temperature is above 77-F/25•C and to 135%for locations where It is below 777/25'C. - - For detailed information,refer to htto://www solaredee us/files/Dills/inverter do o euide odf Built-in module-level monitoring - - Ahigher current source may be used,the Inverter will limit its input current to the values stated. CAN F/Ns are eligible for the Ontario FIT and m croFIT(micmFIT m.SE1140OA-US-CAN). Internet connection"through Ethernet or Wireless Outdoor and indoor installation — Fixed voltage inverter,DC/AC conversion only I i 1 Pre-assembled AC/DC Safety Switch for faster installation Optional—revenue grade.data,ANSI C12.1 USA-GERMANY--ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THENETHERLANDS ISRAEL t> www.solaredge.us .� ". ;� r _� n: a° C�rsrwt .r _ Guy attra+ r �n �. } Format 65.7 in x 39.4 in x1.57 in(including frame) . . . . . - (1670 mm_x 1000 m_m x 40 mm). . . . . . r„wiRlt ,• ;i Weight 44.09 lb(20.0 kg) Frond Cuvuim 0 13--i(3.2 in'i7)thermal).Pre-stiessed glass - .Y .- with anti-reflection technology . . . . . - •++ - 1 Back Cover - Composite film - .. �.. . ., . '.Frame _.Black anodized compatible frame^ � ..� !_:.�-°'-" � � � ' Cell � 6 x 10 polycrystalline solar cells (Junction boxes Protection class IP67,with bypass diodes r3•'• _.. 4-..mm a Solar cable;(+)a47.24in(1200mm),(-)a47 24in(1200 min) �,.n•,w or=� °„H - ! - - . _ P'"'- Connector; Amphenol,^Helios H4(IP68). _ �aI©-I°��'".•-' - PERFORMANCE AT STANDARD TEST CONDITIONS(STC:1000 W/mx,25_`C,AM 1.5G SPECTRUM)'- . . . POWER CLASS(+5W/-OW) - - _ - IW]_ 255 r 260 265 Nominal Power P.., [W] 255 260 - -. 265 • I I I I Short Circuit Current Ian [A] 9 07 9.15 .... . -` - 9.23 . Open Circuit Voltage- - Van IV] .37 54 _ 37.77 - . . Current a4 P., l y [A]T - 8 45 . . 8 53 .�8.62 . . . . i .. Voltage at Pr„ V,,,, IV] 30.18 � .30.46 _ 30.75 L The new Q.PRO-G4/SC is the reliable evergreen for all applications,with 1 Efficiency(Nominal Power) rl, «i _ a15.3: a156_- a15.9 . a black Zep CompatibleTM frame design for Improved aesthetics, opt)- PERFORMANCE AT NORMAL OPERATING CELL TEMPERATURE(NOCT:800W/m',45x3C.AMI:5GSPECTRUM)' k mized material usage and increased safety:The 4th solar module genera- PDwERculss(+SW/-ow) [wr 255 z6o `Y265 - - _ - - _ � � '� 'Nominal Power � Pa„ _[W1 x il 188.3-�� - 192 0 195.7 tion from Q CELLS has been optimised across the board: improved output - - 3'Short Circuit Current Icn [A] - 7.31 7.38- 7.44,. - .. 1. ,. .. _ geld, highero operating reliability and durability,' quicker Installation and I• g ty ty 4 . _ . . � _ _: y P .. - -, � l Open Circuit Voltage Van ,. [V]- . 34.95 M. 16 � � 35.38 . more intelligent.design. j Current at P,,,, I_ �[A] 6.61 R'668 6.75 ' Voltage at P„„ V,,,, [V] -. 28 48 I - 28.75 29 Ol • _ r 'Measurement tolerances STC:t3%(Pm�);±10Y 0.,Va,I� ,V,) 'Measurement tolerances NOCT:t5%(P,_),x 10%(I ,V,1 ,V_) INNOVATIVE ALL-WEATHER TECHNOLOGY PROFIT-INCREASING GLASS TECHNOLOGY _ ® .- Q CELLS PERFORMANCE WARRANTY _ _ - PERFORMANCE AT IRRADIANCE - -.Maximum yields with excellent low-light a Reduction of light reflection by 50%, - - ., LX!� At least 97%of nominal power during 14r i--r r--r-rand temperature behaviour. plus long-term corrosion_resistance due -- first year.Thereafter .6%degra-„ . aft max 0 __ _______ da[ion per Year. ibwn.,.�.°a •Certified fully resistant to level 5 salt fog to high-quality At least 92%bf nominal power after years. E _ _Sol-Gel roller roller coating processing.' . le At least 83%of nominal power after --- -- ( ° 25 years. : n r y 7 ENDURING HIGH PERFORMANCE •Long-term,Yield Security due to Anti EXTENDED WARRANTIES . All data within measurement tolerances. eoo _ - - - • Full warranties in accordance with the A00 1400 .. r. PID Technology',Hot-Spot Protect, ,•investmentsecurityduetol2-year warranty terms of the 0 CELLS sales mRAPIANCEEWA,-I or _ 111 *, c ° ganisation of your respective country. :oo mo .ao sin and Traceable Quality Tra.QTM. - product warranty and 25-year linear - -- _ - o = . t° r, n The typical change in module efficiency at an irradiance of 200 W/m'in relation - rrAas to 1000 W1mr(bath at 25"C and AM 1.5G spectrum)is-2%(relative). •Long-term stability due to VDE Quality performance warranty2. [� _ Q Tested-the strictest test program. - - - '1 TEMPERATURE COEFFICIENTS.(AT 1000W/M',25°C,AM 1.5G SPECTRUM) CiCEIIS lcle _.._ . _ = - - - - Temperature CoeN''nt of.IK a [%/Kl +0 04 Temperature Coefficient of V. - R [%/K] ~� -�0.30 k TOPARAND:Pv Temperature Coefficient of P„PP - _ - �� - - .. SAFE ELECTRONICS - �. . . - } '. � P .'V [%/Kl - -0.41 NOCT [°FT 113 x 5.4(45 t 3°C) - •Protection against.short circuits and e�aort- thermallyinducedpowerlossesdueto 2015 7 Maximum System Voltage Vnn IV] 1000 If EC)/1000(LIL) Safety Class 11 breathable junction box and welded fNaximum series Fuse Rating is Dc] 20 Fire Rating c'i TYPE 1 .• `cables. UL)Max Load( ' [lbsfft'] `50(2400.Pa) Permitted module temperature -.- -40°F up to+185°F- _ on continuous duty (-40°C up.to+85°C) p Phnfn_n_ _ - ' Load Rating(UL)2 [lbs/ft'] 50(2400 Pa) 'see installation manual - - aecus- i_ 0 0 esst p.lyeryndllina - s.la,eudun 2013 }^ UL 1703;VIDE Quality Tested;CEcomplianq Number of Modules per Pallet 26 - "00"svoOmi� °P Oxi IEC 61215(Ed,2);IEC 61730(Eda)application class A _ - - t THE IDEAL SOLUTION FOR: 1D.40D32587 . .. :. Number Pallets per53 centairmr 32 9 pOMPA) N` °S„ Number of Pallets peg 40'Container - 26 - Rooftop arrays - _ V lS^A® - residential buildings pOMPgTj� E _C E c e _ Palle)Dimensions I x W x N) - y 68.7 in x 45.0 in x 46.0in _ - N4,Q ♦♦ ,q I , (1745 x 1145 x 1170.mm) x Pallet Weigh - y 1254 lb(569 kg) �FA v NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of 0 ' APT test conditions:Cells at 1000V against grounded,with conductive metal foil covered module surface, CpMPp•(� this product.Warranty void if non-ZEP c rtified hardware is attached to groove in.module frame. 25°C,168h 2 See data sheet on rear for further information. - Haswha 0 CELLS USA Corp. - 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949748 59 96 1 EMAIL'q-cells-usa®q-cells.com I WEB www.q-cells.us �- Engineered in Germany QCELL.S Engineered in Germany CELLS