Loading...
HomeMy WebLinkAbout0217 OLD MILL ROAD - Health OLD MILL ' v���7ARSTONS MILLS -. 217 _ -LOT 338 I Commonwealth of Massachusetts Title 5 Official Inspection Form 1 Subsurface Sewage Disposal System Form - Not for Voluntary Assessments � ,• 217 Old Mill rd u— Property Address Michael Scheets ; Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important:When A. Inspector Information Sl,,s► /�-/(Dols' filling out forms on the computer, Michael Sears use only the tab key to move your Name of Inspector cursor-do not Robert B Our Co INC. use the return Company Name key. 363 Whites path Company Company Address South Yarmouth Ma. 02664 City/Town State Zip Code 508-477-8877 S114430 Telephone Number License Number B. Certification I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5 (310 CMR 15.000); 1 have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. After conducting this inspection I have determined that the system: 1. ® Passes 0�� �TH OF Mgs�i�i��� 2. ❑ Conditionally Passes �•�`ya`� ........ •sq �. MICHAEL '.N 3. ❑ Needs Further Evaluation by the Local Approving Authority =o: SEARS _ * No.SI14430 :c*a 4. ❑ Fails N SPIE��p�``�`• 6-23-20 Inspector's Si ature Date The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note: This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 1 of 18 f Commonwealth of Massachusetts e Title 5 Official Inspection Form iIb Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 217 Old Mill rd u Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection C. Inspection Summary Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6. 1) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: 2) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass" section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no" or"not determined" (Y, N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old* or the septic tank (whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND (Explain below): t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 18 c Commonwealth of Massachusetts Title 5 Official Inspection Form �I; Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 217 Old Mill yd Propery Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) 2) System Conditionally Passes (cont.): ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): 3) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. a. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: I l5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 18 Commonwealth of Massachusetts a Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 217 Old Mill yd Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh b. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well". Method used to determine distance: *�This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must indicate"Yes" or"No"to each of the following for all inspections: Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form b Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 217 Old Mill rd Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No Static liquid level in the distribution box above outlet invert due to an overloaded El ® or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than '/z day flow ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis and chain of custody must be attached to this form.] ❑ ® The system is a cesspool serving a facility with a design flow of 2000 gpd- 10,000 gpd. ❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no" to each of the following, in addition to the questions in Section CA. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area— IWPA) or a mapped Zone II of a public water supply well t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 217 Old Mill yd V� Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) If you have answered "yes" to any question in Section C.5 the system is considered a significant threat, or answered "yes"to any question in Section CA above the large system has failed. The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6. You must indicate "yes" or"no"for each of the following for all inspections: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ® ❑ Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined? (If they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ® ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ❑ ® Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Ila Subsurface Sewage Disposal System Form -Not for Voluntary Assessments C � 217 Old Mill yd v— Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection D. System Information 1. Residential Flow Conditions: Number of bedrooms (design): 3 Number of bedrooms (actual): 3 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330 Description: Number of current residents: 2 Does residence have a garbage grinder? ❑ Yes ® No Does residence have a water treatment unit? ❑ Yes ® No If yes, discharges to: Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No information in this report.) Laundry system inspected? ❑ Yes ® No Seasonal use? ® Yes ❑ No Water meter readings, if available last 2 ears usage d NA 9 ( Y 9 (gp ))� Detail: Sump pump? ❑ Yes ® No Last date of occupancy: present Date t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 7 of 18 i Commonwealth of Massachusetts Title 5 Official Inspection Form p ' Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 217 Old Mill rd v— Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 2. Commercial/Industrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15.203): Gallons per day(gpd) Basis of design flow (seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ❑ No Water treatment unit present? ❑ Yes ❑ No If yes, discharges to: Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: Last date of occupancy/use: Date Other(describe below): 3. Pumping Records: Source of information: 4-28-17 Was system pumped as part of the inspection? ❑ Yes ® No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 8 of 18 I Ak Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments ............ 217 Old Mill rd u Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) i 4. Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank. Attach a copy of the DEP approval. ❑ Other(describe): Approximate age of all components, date installed (if known) and source of information: 3-18-95 #96-80 Were sewage odors detected when arriving at the site? ❑ Yes ® No 5. Building Sewer(locate on site plan): 30" Depth below grade: feet Material of construction: ❑ cast iron ®40 PVC ❑ other(explain): Distance from private water supply well or suction line: feet Comments (on condition of joints, venting, evidence of leakage, etc.): t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 9 of 18 cam, Commonwealth of Massachusetts Title 5 Official Inspection Form . Subsurface Sewage Disposal System Form - Not for Voluntary Assessments u— 217 Old Mill rd Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 6. Septic Tank(locate on site plan): Depth below grade: 20"feet Material of construction: ® concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain) i4 1500 gal If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No Dimensions: 1500 gal Sludge depth: 4" Distance from top of sludge to bottom of outlet tee or baffle 24" Scum thickness 2" Distance from top of scum to top of outlet tee or baffle 8" Distance from bottom of scum to bottom of outlet tee or baffle 12" How were dimensions determined? sludge gudge, tape Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 1500 gal tank both covers at 19" below grade with in and out tees t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 217 Old Mill rd u� Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 7. Grease Trap (locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 8. Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 18 i c Commonwealth of Massachusetts �n Title 5 Official Inspection Form '_ 1 Subsurface Sewage Disposal System Form -Not for Voluntary Assessments u � 217 Old Mill yd Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. Citylrown State Zip Code Date of Inspection D. System Information (cont.) 8. Tight or Holding Tank(cont.) Alarm present: ❑ Yes ❑ No Alarm level: Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments (condition of alarm and float switches, etc.): *Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No 9. Distribution Box(if present must be opened) (locate on site plan): Depth of liquid level above outlet invert 0 Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): D Box is 16x16 with 2 outlet pipes, box is at 25" below grade t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 12 of 18 i L c Commonwealth of Massachusetts rig , Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 217 Old Mill rd u� Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. Citylfown State Zip Code Date of Inspection D. System Information (cont.) 10. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No* Alarms in working order: ❑ Yes ❑ No* Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): If pumps or alarms are not in working order, system is a conditional pass. 11. Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: Type: ❑ leaching pits number: ❑ leaching chambers number: ❑ leaching galleries number: ® leaching trenches number, length: 2-30' ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 18 f Commonwealth of Massachusetts Title 5 Official Inspection Form I Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 6 � 217 Old Mill rd u— Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. CitylTown State Zip Code Date of Inspection D. System Information (cont.) 11. Soil Absorption System (SAS) (cont.) Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): SAS is 2- 30' trenches both were clean with no sign of failure 12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication.of groundwater inflow ❑ Yes ❑ No Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 14 of 18 f Commonwealth of Massachusetts .. Title 5 Official Inspection Form I; Subsurface Sewage Disposal System Form - Not for Voluntary Assessments >r 217 Old Mill rd u� Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 13. Privy (locate on site plan): Materials of construction: Dimensions Depth of solids Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 15 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form Not for Voluntary Assessments � !%� 217 Old Mill rd Property Address Michael Scheets Owner Owner's Name information is Marstons Mills Ma. 02648 6-23-20 required for every page. Cityfrown State Zip Code Date of Inspection D. System Information (cont.) 14. Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ® hand-sketch in the area below ❑ drawing attached separately Rear LA 0I O a` q l5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 18 I Commonwealth of Massachusetts �n p Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 217 Old Mill rd Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 15. Site Exam: ® Check Slope ® Surface water ® Check cellar ® Shallow wells Estimated depth to high ground water: 25'+ feet Please indicate all methods used to determine the high ground water elevation: ❑ Obtained from system design plans on record If checked, date of design plan reviewed: Date ❑ Observed site (abutting property/observation hole within 150 feet of SAS) ❑ Checked with local Board of Health -explain: ❑ Checked with local excavators, installers- (attach documentation) ❑ Accessed USGS database-explain: You must describe how you established the high ground water elevation: back yard where SAS is located is 25'+ above road with no ground water Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 18 Commonwealth of Massachusetts +� Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 217 Old Mill rd u Property Address Michael Scheets Owner Owner's Name information is required for every Marstons Mills Ma. 02648 6-23-20 page. City/Town State Zip Code Date of Inspection E. Report Completeness Checklist Complete all applicable sections of this form inclusive of: ® A. Inspector Information: Complete all fields in this section. ® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked Z C. Inspection Summary: 1, 2, 3, or 5 completed as appropriate 4 (Failure Criteria) and 6 (Checklist) completed ® D. System Information: For 8: Tight/Holding Tank—Pumping contract attached For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 18 of 18 TOWN BARNSTABLE LOCATION SEWAGE # t°s VILLAGE / 015'z'`Or15 /'��5 ASSESSOR'S MAP dz LOT INSTALLER'S NAME & PHONE NO. SEPTIC TANK CAPACITY ( LEACHING FACILITY:(type) Z -�1-r3 �NO. OF BEDROOMS PRIVATE WELL O UB ATER ©BUILDER OR OWNER DATE PERMIT ISSUED: ; �- ''-- DATE COMPLIANCE ISSUED: "'"/ � � VARIANCE GRANTED: Yes No • 4 �I zt-' /► 2 � t fir` �- 39' aZ W iv lZ ' III L y 3-7 ' 3 �� Pf y' ASSESSORSMAPkk — " �j PARCEL N0:. No... THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE Appliration for Di-npm tl Mirk,i Tonotrnrtion rantit Application is hereby made for a Permit to Construct ) or Repair ( ) an Individual Sewage Disposal System at: --*7 17 �''�- e----�3------..TA!'�l�'L. V- ---!- -------------•--.....----......---- /+ _ ) �o�c on-Address k or Lot No ....-[`s A°0.'....:.ls --.........................•....------•-•-----•----•----------........-----•. --...... t�l ST4 . { �c } 5 Owner Adc ss A W � 7 ! ..4P -.-Q�!. c�C (o �1pagy. Installer {' j Address ,1 Q Type of Building Size Lot__-_� ;_335....Sq. feet Dwelling—No. of Bedrooms---------3-------------------------------Expansion Attic ( ) Garbage Grinder ( ) aOther—Type of Building ............................ No. of persons---------------------------- Showers ( ) — Cafeteria ( ) Q' Other fixtures ---------------- -------------- - - W Design Flow.............5S__......_..._...._..__gallons per person per day. Total daily flow...____ZW....._.__._..__.........__gallons. WSeptic Tank—Liquid capacitv_154r..galIons Length---1_1.......... Width...6.1........ Diameter..--- ---------- Depth__` :Ef x Disposal Trench—No. _. ........ Width...... Total Length...3.1........... Total leaching area.39-.&/1Q..9q,-.ft. Seepage Pit No--------------------- Diameter-------------------- Depth below inlet.................... Total leaching area..................sq. ft. Z Other Distribution box ( ) Dosing tank ( ) � Percolation Test Results Performed by------- _.MG c1-A! �..�_ ..... Date-----3=77.—716............... Test Pit No. I..... .....minutes per inch Depth of Test Pit-T2D-......... Depth to ground water.-MANE........ 44 Test Pit No. 2...`3r..__._minutes per inch Depth of Test Pit-_-�' 2_"_._.... Depth to ground water..." -_-_. - - - O Description of So' —1�M A gdY1-lN.�_•• MD8 $'A/V9.---- x ..-Q `" 3�" R --g-....lion-1 1�.1 �- �ZN '�.." OA rt m...�24 60 w UNature of Repairs or Alterations—Answer when applicable............................__._....................._._........................._.............. .._•••--•••-•--------••................•--•-----.---••••-•-•••••••••••••-•-•--•-----•--••---••--••••-••••--•••••----------------••-----......---------••----•----••••-•-••...................-----•-••-- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Environmental Code—The undersigned further agrees not to place the system in operation until a Certificate of Compliance has been issy d by o rd f hea0h. Signed -.... `- .................. - - ........... ..1........�. Dare Application Approved B ---- - . '" ......... ...Dare----.... ---.. Application Disapproved for the following reasons: ....................................... .................. ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- *...... ......... ......- -------- Permit No. �. '" .. ........................... Issued ........... Dare No... � r Pt'COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE ApVfiratiun for Diripwial Works Tunitrurtiun Vamit Application is hereby made for a Permit to Construct (h) or Repair ( ) an Individual Sewage Disposal System at: ..��?.:C:....33$�o�p...mJ.�...-�'�.............................. 4.3..........PA': oLocation-Address or Lot No. tr Ct ^ri r t it t`� << t?�&e rc t _ ice_ -- ((�� Owner � Address � 1- a1 -...........r-t? l C:'r_ic�. -----•.---••- -7(.'S I )W�P,�j r f>.... t2S'R�►� - Installer Address f U Type of Building Size Lot...._..:�.335.....Sq. feet .., Dwelling—No. of Bedrooms.........3...............................Expansion Attic ( ) Garbage Grinder ( ) a`4 Other—Type of Building ..____. No. of persons............................ Showers g --------------------- P ( ) — Cafeteria ( ) dOther fixtures ...............................•-----.....-----------------•-•------------•---------....------•-•••---•-•••••••••-••••......-•••---•-............•••. w Design Flow.............5.S. .......................gallons per person per day. Total daily flow........ _ .........................gallons. WSeptic Tank—Liquid capacity.15.W_-gallons Length---1-►.......... Width...l----------- Diameter................ Depth..`.:EFF x Disposal Trench—No. __TWv_...`... Width.....3............. Total Length...9_1........... Total leaching area-3.1- a_..fT��_.sq_ft. 3 Seepage Pit No...................... Diameter-------------------- Depth below inlet.................... Total leaching area..................sq. ft. Other Distribution box Dosing tank Z ( ) .. ( ) C CLA aPercolation Test Results Performed by kf.1N1�1.,�..M....�.........N,.....:...1�: Date-----3_.._7.:.��__._......_._.. a Test Pit No. I.._._._z:.....minutes per inch Depth of Test Pit---t2A.......... Depth to ground water..N �;__._... LL, Test Pit No. 2...`Z._-____minutes per inch Depth of Test Pit...1-3.1........ Depth to ground water-.NUA,'�._ R+ '----•---------t-------------------------------------•.. Description of Soil.... ........t...-•1_6....f�:Elo_ ----------•-------------•--------------- w UNature of Repairs or Alterations—Answer when applicable.................................................................................•.•....•...... .......................•-.....------------•-----•--•----•--•------------------•-------.........---••----•----------------------------- ----------------•-------------•-•--------••-•••••-••-------..••-- 1 Agreement: II The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Environmental Code—The undersigned further agrees not to place the system in operation until a Certificate of Compliance has been issued by�thelboard;of health. Signed�. . .t T,:.f.... " o +Vic ... Y t '1 j Dace Application Approved B ...- -y._:. .. Y ....�/ - .�,f .�C �. - e. y....... Application Disapproved for the following reasons: ...................... ... ... .....-----......................... -- . . -- . ............... ........... ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ........................................ �- ce Permit No. 1.... ------------ ----------- Issued --------..�....._:..... .. f>_ Dare �..r. THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE Gertifirate, of Compliance THIS IS TO CERTIFY, That the Individual Sewage Disposal System constructed ( or Repaired ( ) by -------------------i --------------------------------------- ------------ ......-----------------------------.............................. Insta11 at .............. .I >' �� ..- .--------or--------:�1. -.........---------------- has been installed in accordance with the provisions of TITLE 5 of The State Environmental Code as described in the application for Disposal Works Construction Permit No. ........ 1)-------------- dated 2jNfEE 57THE ISSUANCE OF THIS CERTIFICATE SHALL NOT B CONSTRUED AS A GUA THAT fHE SYSTEM WILL FUNCTION SATJ: FACTORY DATE------------- -... - Inspector t `---- --------- -------------------------------------------------- ------ THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE No............. FEE_ 1l75 �t��u��t1 Turku �unutr�r#iun �rrbiit Permission is hereby granted.................... .c�......� Leg ---------------------------------------------------------------------•- to Construct or Repair ( ) an Individual Sewage Disposal System at No....... i' � ..... �-. �� ' ._... 1�`l' � Gam !--------- '� Street /^ � as shown on the application for Disposal Works Construction Per t O.._.._tj.____..__..(�� Dated__�,�.���/_.�.7/4, . Board of Health DATE... -------- ......------•--------------------------•------- FORM 36508 HOBBS&WARREN,INC..PUBLISHERS u Ll p ...... 17,j 1 T:2 tP ........... 4'9 '_4 u;Z 6, -�T 777-'ii� ----ii0oulm"s 4i, Atr -n oll. ......... ;io oe .......... ........... . ............ '7 -4 ki- ilYj-OV 4:Z W -Ul tV C: 4e ,ie iz aFi I lo� 90. iql's .......... 921, A.. V.: IT ........... "b? 521 -Tt�l.......... .......... Jm� 6M ... ...... -'t 3 EXISTING CP*VZOIUR.t� Z' s PR 69 EXISTINGtE -Sl .5 2-5 6sx—T, SPI f T TEST j UTILITY POM -O�- ETAI TAM Xi I............. ow. -14 ST AICL ..................... Q V,' ASSESSORS MAP. 63 Rica zuva PARCEL: 18 TEST HOLE LOGS NOTES: 1. VERTICAL DATUM. ASSUMED FROM QUAD (NGVD +�I N ENGINEER THOMAS MCLELLAN P.E. CURRENT ZONING: RF 2. MiINICAFAL WATER IS AVAILABLE. BUILDING SETBACKS: WITNESS: JERRY DUNNING 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. F 301 S 15 R: 15' DATE: 3-7-96 (P# 8664) 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 PERCOLATION RATE: <"2 MIN/IN LOADING SPECIFICATIONS. FLOOD ZONE: C ` 5.' PIPE PITCH = 114 PER FOOT, (UNLESS NOTED OTHERWISE). TH-1 TH-1 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. LOCUS __ ZLEV A HORIZON E A HORIZON LRV 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE SANDY LOAM SANDY LOAM ' zsY s/t 920 s- z Y s/t 88s USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE UTILITY POLE B HORIZON B HORIZON STATE OF MASS. ENVIRONMENTAL CODE TITLE FIVE AND LOCAL z�m a AY t z.�sY LOAM ( ) LOCATION MAP OLD MILL ROAD t8" / 91n 3s" / 870 HEALTH REGULATIONS. LOT 338 (45,335 SF) BENCHMARK AT HYDRANT 2. 3 C HORIZON C HORIZON 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR YED-COARSE SAND MZD-COARSE SAND TAG BOLT, ELCV= 70 6 „ WITH GRAVEL WITH GRAVEL TO CONSTRUCTION. EDGE OF Pam_ . `_' - -72 _ _ _74 z 5Y 7/4 zsY 7/4 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO � ... 5'' 7s EXCEED3.0'. � 68. 9 �..,. - 11. D-BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 175.68 - - _ _ eo 120- 82s 132"! 794 -82 UTILITY POLE ' 60' _ _ -84 NO GROUNDWATER ENCOUNTERED PHONE RISE� � � � _ � .-86-88 7 _ _ — SEPTIC SYSTEM DESIGN -9z ' -94 FLOW ESTIMATE: BEDROOMS AT 110 GAL/DAY/BEDROOM - 330 GAL/DAY - 72 DECK 4C 96 SEPTIC TANK: 74' ' , PROPOSED ' .S1S1fL_GAL DAY x 2 DAYS = 660 CAL PROPOSED ' 3 BEDROOM r S 500 GALLON SEPTIC TANK zs' s BEDROOM 4 24' 76' 82 b� DWELLING AQ I U E 1 DWELLING ' - DRIVE doh ' vb ' , LEACHING AREA: tr - DECK 10' USE TWO LEACH TRENCHES 80 , • i zo1N { , i . (31' x 3' x 2' DEEP) y PROPOSED DWELLING s { ez' , ' T • +� { SIDE AREA (31 + 3)2 x.2 = 136 84 (.74) 101 GAL/DAY ... . . . . . TH-1 c BOTTOM AREA 31 x 3 ='93 SF (74) = 69 GAL/DAY 86 , _ _ TOTAL CAPACITY,.= 170 GAL/DAY 88 � � TH-2� _i 96 _ .. x 2 TRENCHES 340 GAL/DAY '90' 94 92 SEPTIC SYSTEM SECTION z" PEASTONE a . 82, ` • 90 COVERS WITHIN 12" OF FINISHED GRADE 314 - 1 V 2" \ 90.0 ONE INSPECTION COVER TOP OF FOUNDATION 0 BE WITHIN 6" OF GRADE) WASHED STONE 4" PERFORATED 92 PVC PIPE ELEV. 86.44 86.41 ELEV. D-BOX 83.94 1 t�0 GAL 86.16 ELEV. Z87.O ELEV. SEPTIC TANK 86.33 (6" OF ELEV. 31' ELEV (6" OF STONE UNDER OR ELEV. STONE MECHANICALLY COMPACTED) UNDER) TWO LEACH TRENCHES 86.0 (3P x 3' x 2' DEEP) TEE SIZES: INLET: 6" UP, 13" DOWN ELEV. OUTLET: 6" UP, 14" DOWN 175. 00' x KEY: SITE AND SEWAGE PLAN EXISTING CONTOUR: CONTOUR: APPROVED BY. DATE: PROPOSED .............. ........... ' EXISTING SPOT. ELEVATION: 25.5 r ,���.< : . LOCATION.• PROPOSED SPOT ELEVATION. 25 �- (� A ,.�:.. LOT 338 OLD MILL ROAD TEST HOLE. c UTILITY POLE. --0- � a � MARSTONS MILLS, MA q IblcL�LU, {el,� .FENCE LINE. .• _ s/A+. c -. •.�:,� 1 L (F, v t . 71 PREPARED FOR: HYDRANT. -� 9� ti , ' ;. w. c EP * St RETAINING WALL. .. REEF REALTY y TREE: d DEYARZST-YcLSLLAN ENGINEERING SCALE: 1" = 30' DATE: 3-11-96 STAKE-SET. 24 SCHOOL STREET P.O. BOX 463 REFERENCE: LAND COURT CASE 30751F (APRIL 1970) wasr DENNIS, YAssAcBvsarrs 02670 " JOHN Z. DEMAREST`'JR., P.L.S. DM # �¢� (D17F6) �THO�fAS McLELLAN P E. .Y t � i i