Loading...
HomeMy WebLinkAbout0054 ROUTE 149 - Health 54 ROUTE 149 Marstons Mills A - 077 — 023 Town of Barnstable DIME 1 Regulatory Services Richard V. Scali, Interim Director BARNSTMM r MAM Public Health Division s6;9. 1®� '°rFaMaY°i Thomas McKean, Director 200 Main Street,Hyannis,MA 02601 Office: 508-862-4644 Fax: 508-790-6304 Installer& Designer Certification Form Date: Sewage Permit# p()N Q\ — `IJ� Assessor's Map\Parcel=_�L3 Designer: A- t+r411-5 P Installer: Zc_�,Ue�\ Address: g 2 3 R_0-W 7-L (DA Address: t \a Cry\ 2r7. pe,,zr, r4.4, ae 4,7; X On i�A_ �b was issued a permit to install a . date) (installer) septic system at tA,`NS based on a design drawn by (address) 14. H-AA5, Pe dated (designer) j I certify that the septic system referenced above was installed substantially according to the design, which may include minor approved changes such as lateral relocation of the distribution box and/or septic tank. Strip out (if required) was inspected and the soils were found satisfactory. I certify that the septic system referenced above was installed with major changes (i.e. greater than 10' lateral relocation of the SAS or any vertical relocation of any component of the septic system) but in accordance with State & Local Regulations. Plan revision or certified as-built by designer to follow. Strip out (if required)-was inspected and the soils were found satisfactory. I certify that the system referenced above was constructed in c4mgliance with the terms of the I\A approval letters (if applicable)_6& r r nstaller's Signature) 51•', Designer's Signature) (Affix Designer's Stamp Here) PLEASE RETURN TO BARNSTABLE PUBLIC HEALTH DIVISION. CERTIFICATE M AN AS- OF COMPLIANCEWILL NOT BE ISSUED UNTIL BOTH THIS BUILT CARD ARE RECEIVED BY THE BARNSTABLE PUBLI HEAT H DIVISION. THANK YOU. Q:\Septic\Designer Certification Form Rev 8-14-13.doc t t MYERSO SRIV14 SERIES The Myers®SRM4 series residential sewage pumps are considered by industry pros to be extremely reliable.The specially designed recessed impeller allows 2"solids to easily pass through : " without jamming.The cast iron housing and volute case handle the harshest conditions and will provide years of service. d . Automatic and manual operation models available. a f I Sewage, high-capacity sump, effluent i c Versatile Applications Excess Heat Detection Effective and efficient performance in Internal heat sensor provides overload Capacities-95 GPM (360 LPM) septic tank sewage, effluent and high- protection;automatically resets when Shut-off Head- 19' (5.8 m) capacity sump applications motor cools to a safe operating Solids Handling-2" (50.8 mm) Handles the Heat temperature Liquids Handling-Septic effluent High-endurance,oil-cooled motor for Free-flow Design and sewage continuous bearing lubrication and Recessed impeller design also Intermittent Liquid Temperature- critical heat dissipation improves the free flow of solids Up to 140°F(60°C) Powerful Torque up to 2" Motor/Electrical Data-4/10 HP, High-torque, permanent split Longer Bearing Life permanent split capacitor type, 115V, 12A, capacitor(PSC) motor; no starting Recessed impeller reduces radial 10,60Hz;230V,6A, 10,60Hz switches or relays to wear out bearing loads, increasing bearing life Acceptable pH Range-5-9 Motor Protection Automatic and Manual Discharge,NPT-2" (50.8 mm) Long-life carbon/ceramic seal Automatic tethered or vertical switch Housing- Heavy cast iron provides extra protection against models(with piggyback plug),or P P 9 P 99Y P 9 , Power Cord- 10'120'optional) water leaks manual operation models Impeller-Recessed,thermoplastic Volute Case-Cast iron Shaft Seal-Type 11A, carbon and ceramic ►�PENTAIR TOWN OF BARNSTABLE LOCATION NiA cl SEWAGE# tL()\ l O 1 VILLAGE \15 ASSESSOR'S MAP&PARCEL INSTALLER'S NAME&PHONE NO. QN�� Vr s c A V` �'(i�{ a.Cl%A ()0 6�1 SEPTIC:TANK CAPACITY \50 0 9 k-w',k :k- 9v m P LEACHING FACILITY:(type) S-M &k(size) 1 a-!FS' k a S NO.OF BEDROOMS OWNER W� PERMIT DATE: (Li COMPLIANCE DATE: Separation Distance Between the: n l /( Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility �y A Feet Private Water Supply Well and Leaching Facility(If any wells exist on site or within 200 feet of leaching facility) AIA Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leaching facility) `p f�) C7 Feet FURNISHED BY �,�✓ ate cs_ y-1 Li Cl, VA ab p Qox �9 t e a����� No. ' Fee THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLE, MASSACHUSETTS Yes ftplitation for Vsposal *pstem Construction Permit Application for a Permit to Construct( ) Repair(t4pgrade( ) Abandon( ) ❑Complete System ❑Individual Components Location Address or Lot No.S4 Q� i y I Owner's Name,Address,and Tel.No. Assessor's Map/Parcel / a 6 9.11 n M \I Installer's Name,Address,and Tel.No. Designer's Name,Address,and Tel.No. Type of Building: -Yo Jr— X9 V 0065 Dwelling No.of Bedrooms Lot Size sq.ft. Garbage Grinder(/VIA4 Other Type of Building No.of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow(min.required) x 3 0 gpd Design flow provided f gpd Plan Date�� 1 t Number of sheets Revision Date Title Size of Septic Tank L'Z O Type of S.A. 0 ��Lh(. C t�c,�6P W C 4 Description of Soil Nature of Repairs or Alterations(Answer when applicable) Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certificate of Compliance has been issued by is Board of Health. gn d ate / r" on Application Approved by J ate Application Disapproved by d Date for the following reasons Permit No. �' Date Issued --------------- No. / Fee C/V THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: PUBLIC HEALTH DIVISION -_TOWN OF BARNSTABLE;MASSACHUSETTS applitation for MispoBal 64t'pm Construrtion 3pPrmit Application for a Permit to Construct( ) Repair(t/Upgrade( ) Abandon( y) ❑Complete System ❑Individual Components Location Address or Lot No. y 2a( I Fa'Owner's Name,Address,and Tel.No. ,� t.err�e�n ;\I Assessor's Map/Parcel C lei•r-C,, �a ¢ QX n M Installer's Name,Address,and Tel.No. "' _ Designer's Name,Address,and Tel.No. nr 3f�. �S(3 Type of Building: poi(- d•`)V 0O61 Dwelling No.of Bedrooms - Lot Size sq.ft. Garbage Grinder(/"A f qAX- Other Type of Building No.of Persons Showers( ()•Cafeteria(• ) ; Other Fixtures Design Flow(min.required) � �(� gpd Design flow provided Q S� gpd lan Date Lam' 1 Number of sheets Revision Date A ' Title a el'G�lG` d• ri Size of Septic Tank /SO O Type of S.A. 0 a G��(,,,,/� C X r7 I U 4,f Description of Soil C CG+r s Nature of Repairs or Alterations(Answer when applicable) ' Date last inspected: Agreement: J t The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certificate of .Compliance has been issued by is Board of Health. gn d, ate L ` Application Approved by "" Date Application Disapproved by Date for the following reasons i t' Ir Permit No.A Date Issued THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE, MASSACHUSETTS (ertificat>e of Compliance THIS IS TO CERTIFY,that the On-site Sewage Disposal system Constructed( ) Repaired(L, S Upgraded( ) Abandoned( )by SC pS� D�� at ���T� (�(�cr5�K3 r, M j\`S has been cons cted'n a c ance with the provisions of Title 5 and the for Disposal System Construction Permit No. dated Installer �G FC(�/�� Designer S `� #bedrooms Approved desi flow 3L gpd The issuance of this e t s al of b construed as a guarantee that the system i i fu des ed al G Date Inspector J - /� - - ----------- --------------------------------------- ----------L ------------------------------- No. v /O/ t, Fee THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION-BARNSTABLE,MASSACHUSETTS 30isposal *pet ConetrUttion Vermit Permission is hereby granted to Construct( ) Repair( ) Upgrade( ) Abandon( ) 1 System located at , cj M G.r Ski Z)k M and as described in the above Application for Disposal System Construction Permit. The applicant recognized his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided:Construct on ust a om eted within three years of the date of this permit. Date Approved by Town of oFml�t 1 ak_ Department of][regulatory Services �Aa ; Public Health Division gate MA AL 200 Main Stree Hyannis MA 02601 ^� Date Scheduled Time � .. JFVe IBd. � f c fo Performed By: — Witnessed By: /� LOCATION & GENERALWF011;11�ATj0,N Location�C res ` N � Owner's Name 0 Address F°je& z/t Assessor's Map/Parcel: `77� Engineer's Name Sk v-f, kkr NEW CONSTRUCTION REPAIR _✓ Telepli one tk Sz 8' t3�, Land Use" A?­CS Slopes(%) le_> Surface Stones Distances from: Open Water Body ft Possible Wet Areay ft Drinking Water Well ft Drainage Way L5 ft Property Line ft Othcr ft 01�'+�"1'CH'(Street name,dimensions of lot,exact locations of test(toles&pete tests,locate wetlands(n proximity to holes) CA } 4 W Parent material(geologic) G>✓��.yt5�� Depth to Bedrock Depth to Groundwater. Standin Walerin Hole: 1' T�— g �' /. Weeping froth Pit 11II06 Estimated Seasonal High Oroundwater c" r DETERMINATION FOR A SQNAL 111GZ OWATER TABLE Method Used: <JC3•�r t ref-�� `ji"�' .r~ir�7i7L.t1j Depth Observed standing in obs.bole: In. Depth to loll mottles: _ T In. Depth to weeping from side of obs-bole: b, Groundwater AdJuatment Ct. Index Well# Reading Data: index Well level�� Adj.factor__ ArIJ.C)rtlulldwalerLevel PEI RCOLATION`]('EST D A 1;e i2- Observation Hole# Time lit 9" Depth of Perc C16 t Tlute ul 6" ems'✓ y _ Start Pre-soak Time @ C� "r' Time(9"-6") End Pre-soar[ .La� Rate Min./Inch L- Site suitability Assessrnrnt: Site Passed ✓ Site Pailed: Additional Testing Needed(Y/N) A Original: Public Health Division Observtitioll Holc Data To Be Completed on�. Back---------- i ***1f percolation test is to be conducted witliin 100' of wetland,you must filrst notify tile, Barnstable Conservation Division at least one (1) week prior to beginning. l;Z;�.Sftrrlt�Pr!RCroRM.Doc DE,EI'JP.O BSIirR VATIC9N HOLE LOG ,dole Depth from Soil Horizon Soil Texture Sdil Color Soil. Other Surface(in.) (USDA) (Munsell) Mottling (Stnucture,Stones;Boulders. onsistena 3 aravei) 32,Of f-I L ` DEEP OBSERVATION HOLE LOG Hole# Z- Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulders. o siste r vel <.t A v��3/j ZYP !t 1 DEEP OBSERVATION HOLE LOG Dole# Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Munsell) Motutng (Structure,Stones,Bouldets. Cons Istency,TP Oraych DEEP OBSERVATION DOLE LOG Dole# Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulders, Consistency, 6 a I'loud Insurance]Rate Ma_l�: Above 500 year flood boundary No- Yes "Within 500 year boundary No"�Yes Within 100 year flood boundary No _ Yes Depth of Nattirally Occurring Pervious Material Does at least four feet of naturally occurring pervious material exist in all areas observed throughout the area proposed for the soil absorption system? If not, what is the depth of naturally occurring pervious material? Certification /r(c�y I certify that on !r `��' f--(date)1 have passed the soil evaluator examination approved by the Department of Environmental Protection and that the above analysis was performed by me consistent with . the required trainirl xp rtise and experience described in 10 CMR 15.017. Signature Date J " s QASEPTIC�PERCPORM.DOC ACCESS COVER MUST BE 9' MINIMUM. MIN 2" OF PEASTONE INVERT ELEVATIONS : DESIGN CR I TER I A : N TO FINISH GRADE FIRST 2 TO OR FILTER FABRIC 3' MAXIMUM COVER INVERT AT BUILDING: 88.5 DESIGN FLOW: BE LEVEL 4*VENT WITH ACCESS COVERS MUST BE WITHIN TEE (CHARCOAL FILTER INVERT IN SEPTIC TANK: 87.75 3 BEDROOMS AT 1/0 G.P.D. PER � w 6" OF FINISH GRADE la'" MIN INVERT OUT SEPTIC TANK: 87.5 BEDROOM EQUALS 330 G.P.D. Qo A/q/N INVERT IN DIST. BOX: 96.27 sr 3/4" - I l/2" DIA. NO GARBAGE GRINDER LOCO 91.0 INVERT OUT DIST. BOX: 96. 1 96.27 _ DOUBLE WASHED STONE INVERT IN LEACH CHAMBER: 96.0 ROUTE 2 SEPTIC TANK REQUIRED: 2" SCH 40 PVC %0 96. I 2 O i°D 94.0 88.s BOTTOM OF LEACH CHAMBER: 94.0 SLOPE 96.0 330 G.P.D. X 200% - 660 GAL. 4' DIAM P/PE 2-500 GAL LEACHING CHAMBERS ADJUSTED GROUND WATER: 87. 1 3 OUTLET W/4 ' STONE AROUND. 12.8'w x 25'1 x 2 'd SEPTIC TANK PROVIDED: 1500 GAL. MIN. 88.5 D-BOX OBSERVED GROUND WATER: 82.6 87.75 LEFFNT H-20 BOTTOM OF TEST HOLE2: 89.0SOIL ABSORPTION SYSTEM REQUIRED: c soo G 3.2 INDEX WELL SDW 253. ZONE C DESIGN PERC RATE C 5 M!N/l NCH 2000 GALLON H-10 JANUARY 2014 READING-49.2', ADJ-4.5' SOIL TEXTURAL CLASS - / MONO 2 COMPARTMENT EFFLUENT LOADING RATE - 0.74 GPD/SF SEPTIC TANK/PUMP CHAMBER 6" CRUSHED STONE OR 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED LOCUS MAP COMPACTED BASE PROVIDED: 2-500 GAL LEACHING CHAMBERS W/4 ' STONE AROUND, A-471 S.F. GENERAL NOTES : PROFILE .' Nor TO SCALE 471 S.F. x 0. 74 - 348 G.P.D. I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION SO I L TEST PIT DATA s OF THE SEWAGE DISPOSAL SYSTEM ONLY. INDICATES INDICATES 2. VERTICAL DATUM IS ASSUMED, FOR BENCH MARKS PERCOLATION OBSERVED TEST GROUNDWATER SET. SEE SITE PLAN. TP #l P#l 4241 TP #2 3. ALL CONSTRUCTION METHODS.AND MA TER 1 AL S AND �� �P�� t� HORIZON TEXTURE COLORHORIZON TEXTURE COLOR MAINTENANCE OF THE SEPTIC SYSTEM SHALL �` 0" 90.6 0' 99.0 CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL FILL A LOAMY IOYR �0 SAND 3/3 BOARD OF HEALTH REGULATIONS. ' 6 / '12oaK 32" - - - - - - - - - - - - - - - - - - - - 87.9 18" - - - - - - - - - - - - - - - - - 97.5 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER 0.�� \ A LOAMY IOYR B LOAMY IOYR j \ \ 3/3 AREAS SUBJECT, TO VEHICULAR TRAFFIC OR GREATER / p,� \ \ SAND SAND 5/8 THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- CATCH BASIN '( ��� / \\ \o COARSE IOYR STANDING H-20 WHEEL LOADS. \ uP��. �i \ ' N SAND 5/8 BM. TAG BLT 1I18 / I 80" - - - - - - - - - - - - - - - - - - - - 83.9 5. ALL •SEWER PIPE SHALL BE SCHEDULE 40 PVC OR EL-98.88 i _ \ ��\ MEDIUM IOYR APPROVED EQUAL. SAND 6/1 \ i TP#2 \\ I REROUTE WATER LINE 96" _ 82.6 48" 6. SEP T t C TANK, PUMP CHAMBER AND D-BOX SHALL BE \ \ I \ AROUND LEACHING AREA REINFORCED PRECAST CONCRETE. WATERTIGHT AND `, \\ •';'• \\ I SLEEVE WITH A LARGER DIAMETER WATERPROOF. D-BOX SHALL BE WATER TESTED TO - ' \ VENT \ PIPE WHEN CROSSING OR WITHIN 102" - - - - - - -LOAMY- - - - - 7.SYR 82. 1 ��' '•��•• � •' \ \ 10' OF SEPTIC SYSTEM CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. /00 �.. :.:: \\ .n SAND 2.5/3 R/`FR N .::7 108- 81.6 I20 ND WATER" 89.0 7. BEFORE CONSTRUCTION CALL "DIG-SAFE". 2-500 GALLON \ t•'• ' \ DATE: JANUARY 9. 2014 l 888-DIG SAFE AND THE LOCAL WATER DEPT. LEACHING CHAMBERS 12•spIpuc \ \ 0 c' FOR LOCATION OF UNDERGROUND UTILITIES. W14' STONE AROUND �' TEST BY. STEPHEN HAAS ` WITNESSED BY: DONNA MIORAND! 8. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE p'sP�GcE 2 MlN/INCH PERC RATE: C DESIGN ENGINEER TWO DAYS PR 1 OR TO CONSTRUCTION OF THE SYSTEM TO ALLOW FOR SCHEDUL 1 NG OF THE CONSTRUCTION INSPECTIONS. �r I b 9. EXISTING SEPTIC SYSTEM TO BE PUMPED DRY AND BACKFILLED. /0. ALL UNSUITABLE MATERIAL (A & B HORIZONS) _- ENCOUNTERED BELOW THE INVERT OF THE LEACHING FA I L I TY TO BE REMOVED FOR A D 1 S TANCE` OF 5* AROUND AND REPLACED WITH SAND IN ACCORDANCE - -9 WITH TITLE 5. Q� ___ � - ��o 2000 GALLON ? COMPARTMENT . 94-' SEPTIC/PUMP TANK 1 s i �G EXISTING SEPTIC �• g, s 9� SYSTEM ER 3 D.c- 19 Q� `� CB FND ./ �F9 ��b ---'�� PORCH l`(p�/ f ER 4 \\ C1 WORK-L-lMl_T AT EDGETHRE OF DRIVEWAY-\ EX ISTtNG W LLIN FLAG BEDROOM �! �•' '�--,. � R8-__ ^� t FLAG 82.8 SHED \ VARIANCES REQUIRED : TOWN OF BARNS TABLE ONS l TE SEWAGE -D!SPOSAL REGUL A T l ONS ER 5 \s4 T A R EA L O w \ a, PART V 111. SECTION l.00. THE "l 00 FOOT* REGULATION 56.978+ S. F. o 100' IS REQUIRED BETWEEN ANY PORTION OF THE SEWAGE DISPOSAL SYSTEM AND A WETLAND RESOURCE. FLAG 82,s m 83' AND 87' ARE PROPOSED BETWEEN THE SEPTIC TANK / PUMP CHAMBER AND THE RESOURCE AREAS. F 17' AND 13' VARIANCES ARE REQUESTED. ER 6 � _ 8VW 22 82.OVW 211 BVW 20 82.3 i ' BVW17 BVW16 SEPT / C SYSTEM DES / GN / 'c .az BVW /9 BVW /8 �� 54 ROUTE 149 . MAP 77 . PARCEL 23 111 ER 7 90 CMARST0NS M ! LLS ) B`Vk15 BARNS TA E . MA . 1 20- D/AM �' I i' PREPARED FOR MINIMUM � COUP/L I" x _ - ER 9 `\ , LEGEND C L .A I R E S H E R M,A N �'-r2- PVC OUTLET ER 8 _ � �� / SHFD �'/ PUMP SYSTEM NOTES: - BVW 14 ■ CB CONCRETE BOUND \ P . 0 . BOX 21 / MARS TONS MILLS . MA 02648 o � -W WATER L l NE 1. PUMP TO BE MY£RS RESIDENTIAL SEWAGE PUMP MODEL SRM4 2 v aS� ER /0 ` _ i/ O HYDRANT OR EOUAL. 30 GPM O 15 FT TON 3/aH#EEP v� ,- r -G GAS L I NE SCALE : ! 2 O MARCH 3 2014 S, /, 2. THE PUMP SHALL START AND STOP AT THE ELEVATIONS SHOWN. 1500 GALLON CHECK •�� j/ALARM ON 0/{py- OVER HEAD WIRES VALVE /�• STEPHEN A HAAS SEPTIC TANK - - - - - NON-MERCURY \ / L l GHT POST • 3. THE PUMP SHALL BE INSTALLED IN STRICT CONFORMANCE WITH pip ON (LOAF SWITCHES ' E N G 1 N E E R I N G , 1 NC THE MANUFACTURER'S SPECIFICATIONS AND TITLE V REGULATIONS. EFFLUENT - - - `_ -9 VW /3 -E- UNDERGROUND ELECTRIC LINE PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD BE ABLE TO FILTER d' Aw- PUMP - ER l! - PUMP OFF _-80-_- -T- UNDERGROUND TELEPHONE LINE /�^: BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAMBER WITHOUT V MP 923 R o u t e 6 A BE DISCONNECTED To ENTER THE PUMP D OUT R. -CTV- UNDERGROUND CABL FV I S ION LINE / // /'-_�� Y a r mo u t h p o r t , + 40.4 SPOT ELEVATION MA 02675 4. THE ALARM SHALL START AT THE ELEVATION SHOWN AND BE `" �� i S O 8 3 6 2-8 1 3 2 PUMP DETAIL :NOT To SCALE ....... EXISTING ExlsT/NG coNrouR r� POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER. ER 12 BRw F4 01 PROPOSED CONTOUR USING 500 GAL, PUMP CHAMBER Q /0 20 40 S. AN ELECTRICAL PERMIT MUST BE OBTAINED FOR -THIS INSTALLATION. JOB NO: !3- 1 17