Loading...
HomeMy WebLinkAbout0061 RUSSELLS PATH - Health 61 RUSSELLS PATH, MARSTONS MILLS A= 027 014 Imo_ S-11\ Commonwealth of Massachusetts Executive Office of Enviromnental Affairs Dept. of Environmental Protection One winter Street Boston Ma. 02108 IN .Tolui Cci ' D.E.P. Title V Septie Inspector P.O. Box 2 }9 MAR 2TTa�et, MA�()X2536 �64=6:y 3 WILLIAM F.WELD O rOWNOFBgR Governor HfA(TyOESpB(E ARGEO PAUL CELLUCCI Lt.Governor SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION PART A 8 CERTIFICATION Property Address: 61 Russells Path Marstons Mills a� �� Address of Owner: Date of Inspection: 3117198 (If different) Name of Inspector: John Graci Jim Willmott:105 Watershed Way Marstons Mills I am a DEP approved system inspector pursuant to Section 15.340 of Title%(310 CMR 15.000) Company Name,Address and Telephone Number: CERTIFICATION STATEMENT I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true,accurate and complete as of the time of inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. The system: X Passes This Inspection Is based on criteria defined in Title V _ Conditionally Passes code 310 CMR 16.303.My findings are of how the system is performing at the time of the inspection.My Inspection does _ Needibmit he Evaluation By the Local Approving Authority not Imply any warranty or guarantee o►the longevity ofthe Fells septic system and any of Its components useful life. Inspector's Signature: Date: 3119198 The System Inspector shall sa copy of this inspection report to the Approving Authority within thirty(30)days of completing this inspections. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the Department of Environmental Protection. The original should be sent to the system owner and copies sent to the buyer,if applicable and the approving authority. INSPECTION SUMMARY: Check A, B,C,or D: A] SYSTEM PASSES: x I have not found any information which indicates that the system violates any of the failure criteria defined as in 310 CMR 15.303. Any failure criteria not evaluated are indicated below. COMMENTS: B] SYSTEM CONDITIONALLY PASSES: One or more system components need to be replaced or repaired. The system,upon completion of the replacement or repair,passes inspection. Indicate yes,no,or not determined(Y, N,or ND). Describe basis of determination in all instances. If "not determined",explain why not. The septic tank is metal, unless the owner or operator has provided the system inspector with a copy of a Certificate of — Colttpliance(attached)indicating that the tank was installed within twenty(20)years prior to the date of the inspection, or the septic tank,whether or not metal, is cracked, structurally unsound, shows substantial infiltration or exfillration, or tank failure is imminent.The system will pass inspection if the existing septic tank is replaced with a conforming septic tank as approved by the Board of Health. (revised 04127)97) One Winter Street • Boston,Massachusetts 02108 • FAX(617)556-1049 • Telephone(617)292-5500 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 01 Russells Path Marstons Mills Owner: Jim Willmott:105 Watershed Way Marstons Mills Date of Inspection:3117199 _ Sewage backup or.hreakout or hioh.static water level observed.in.the distribution b.ox is due to a broken. or obstructed pipe(s)or due to broken,settled or uneven distribution box.The system will pass inspection if (with approval of the Board of Health). Describe observations: broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced The system required pumping more than four times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed C] FURTHER EVALUATION IS REQUIRED BY THE BOARD OF HEALTH: Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect the public health,safety and the environment. 1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES THAT THE SYSTEM IS NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh. 2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH (AND PUBLIC WATER SUPPLIER,IF APPROPRIATE) DETERMINES THAT THE SYSTEM IS FUNCTIONING IN A MANNER THAT PROTECT THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT: The system has a septic tank and soil absorption system and is within 100 feet to a surface of water supply or tributary to a surface water supply. The system has a septic tank and soil absorption system and is within a Zone 1 of a public watersupply well. The system has a septic tank and soil absorption system and is within 50 feet of a private water supply well. The system has a septic tank and soil absorption system and the SAS is less than 100 feet but 50 feet or more from a private water supply well, unless a well water analysis for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presense of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm. Method usedto determine distance (approximation not valid) 3)Other D] SYSTEM FAILS: You must Indicate either"Yes"or"No"as to each of the following: I have determined that the system violates one or more of the following failure criteria as defined in 310 CMR 15.303. The basis for this determination is identified below. The Board of Health should be contacted to determine what will be necessary to correct the failure. Yes No Backup of sewage in facility or system component due to an overloaded or clogged SAS or cesspool. Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or rlogged cesspool. SAS is in hydraulic failure. (revised 04127197) SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 01 Russells Path Marstons Mills Owner: Jim Willmott:105 Watershed Way Marstons Mills Date of Inspection:3117199 D]SYSTEM FAILS(continued) Yes No Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool. Liquid depth in cesspool is less than 6"below invert or available volume is less than 1/2 day flow. Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Numbers of times pumped Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater elevation. Any portion of a cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. Any portion of a cesspool or privy is within a Zone 1 of a public well. Any portion of a cesspool or privy is within 50 feet of a private water supply well. Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. If the well has been analyzed to be acceptable,attach copy of well water analysis for coliform bacteria,volatile organic compounds, ammonia nitrogen and nitrate nitrogen. E] LARGE SYSTEM FAILS: You must indicate either"Yes"or"No"as to each of the following: The following criteria apply to large systems in addition to the criteria: The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a significant threat to public health and safety and the environment because one or more of the following conditions exist: Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area(IWPA)or a mapped Zone II of a public water supply well) The owner or operator of any such system shall bring the system and facility into full compliance with the groundwater treatment program requirements of 314 CMR 5.00 and 6.00. Please consult the local regional office of the Department for further information. (rsylsed 04127)87) f SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECLIST Property Address: lit Russells Path Marstons Mills Owner: Jim Wlllmoti:105 Watershed Way Marstons Mills Date of Inspection:3117199 Check if the following have been done:You must indicate either"Yes"or"No"as to each of the following: _x_ — . Pumping information was requested of the owner,occupant,and Board of Health. x None of the system components have been pumped for at least two weeks and the and the system has been receiving normal — — flow rates during that period. Large volumes of water have not been introduced Into the system recently or as part of this inspection. — x As built plans have been obtained and examined. Note if they are not available with N/A. x — The facility or dwelling was inspected for signs of sewage back-up. x — The system does not receive non-sanitary or industrial waste flow. _X— — The site was inspected for signs of breakout. x All system components,excluding the Soil Absorption System,have been located on the site. x The septic tank manholes were uncovered,opened,and the interior of the septic tank was inspected for condition of baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge,depth of scum. x _ The size and location of the Soil Absorption System on the site has been determined based on The facility owner(and occupants, if different from owner)were provided with information on the proper maintenance of Sub-Surface Disposal Systens. x Existing information. Ex. Plan at B.O.H. x Determined in the field(if any failure criteria related to Part C is at issue, approximation of distance is — — unacceptable)[15.302(3)(b)] I pevlaed 04127187) SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 01 Russells Path Marstons Mills Owner: Jim Wilimott:105 Watershed Way Marstons Mills Date of Inspectlon:3117199 FLOW CONDITIONS RESIDENTIAL: Design flow: 220 g•p•d./bedroom for S.A.S. Number of bedrooms: 2 Number of current residents: 0 Garbage grinder(yes or no): No Laundry connected to system(yes or no): yes Seasonal use(yes or no): No Water meter readings,if available:(Iast two(2)year usage(gpd): rda Sump Pump(yes or no): No Last date of occupancy: last spring COMMERCIAL/INDUSTRIAL: Type of establishment: We Design flow:o gallons/day Grease trap present: (yes or no) No Industrial Waste Holding Tank present:(yes or no) No Non-sanitary waste discharged to the Title 5 system:(yes or no) Na Water meter readings,if available: nra Last date of occupancy: nra OTHER:(Describe) We Last date of occupancy: GENERAL INFORMATION PUMPING RECORDS and source of information: System was pumped last spring System pumped as part of inspection: (yes or no)No If yes,volume pumped:0 gallons Reason for pumping: rVa TYPE OF SYSTEM x Septic tank/distribution box/soil absorptions system Single cesspool Overflow cesspool Privy Shared system(yes or no) ( if yes, attach previous inspection records,if any) I/A Technology etc.Copy of up to date contract? Other: APPROXIMATE AGE of all components, date Installed(if known)and source Information: B9 years Sewage odors detected when arriving at the site: (yes or no) No (revised 04117)971 f SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 01 Russells Path Marstons Mills Owner: Jim Willmod:105 Watershed Way Marstons Mills Date of Inspection:3117199 SEPTIC TANK: x (locate on site plan) Depth below grade: V Material of construction:x concreate metal FRP Polyethylene—other(explain) If tank is metal, list age nla . Is age confirmed by Certificate of Compliance No (Yes/No) Dimensions: Le6^H57^w4'10" Sludge depth:7" Distance from top of sludge to bottom of outlet tee or baffle: 2e" Scum thickness:V Distance from top of scum to top of outlet tee or baffle:6" Distance form bottom of scum to bottom of outlet tee or baffle: 17" How dimensions were determined: measured Comments: (recommendation for pumping,condition of inlet and outlet tees or baffles, depth of liquid level in relation to outlet invert,structural integrity, evidence of leakage,etc.) Septic tank and ell components are structurdy Bound and functioning property.Recommend pumping every two years. GREASE TRAP: (locate on site plan) Depth below grade: rda Material of construction: _concrete_metal_FRP_Polyethylene_other(explain) Dimensions: rda Scum thickness:rda Distance from top of scum to top of outlet tee or baffle:nfa Distance from bottom of scum to bottom of outlet tee or baffle:rda Date of last pumping;,r, Comments: (recommendation for pumping,condition of inlet and outlet tees or baffles, depth of liquid level in relation to outlet invert, structural integrity, evidence of leakage,etc.) rda BUILDING SEWER: (Locate on site plan) Depth below grade: iv- Material of construction:_cast iron x 40 PVC_Other(explain) Distance from private water supply well or suction line:t— Diameter: 4" Qmments: (conditions of joints,venting,evidence of leakage,etc.) (revised 042P97) SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 61 Russells Path Marstons Mills Owner: Jim Wlllmott:105 Watershed Way Marstons Mills Date of Inspection:Y17199 TIGHT OR HOLDING TANK: (locate on site plan) Depth below grade: rda Material of construction:_concrete_metal_FRP_Polyethylene_other(explain) Dimensions: nra Capacity: We gallons Design flow: We gallons/day Alarm level:_nra Alarm in working order?_Yes_No Date of previous pumping: Comments: (condition of inlet tee,condition of alarm and float switches,etc.) nra DISTRIBUTION BOX: x (locate on site plan) Depth of liquid level above outlet invert: liquid level witnbottomofpipe. Comments: (note if level and distribution is equal, evidence of solids carryover,evidence of leakage into or out of box etc.) D-Box Is structurally sound. PUMP CHAMBER: (locate on site plan) Pumps in working order:(yes or no)No Alarms in working order(yes or no)_ves Comments: (note condition of pump chamber,condition of pumps and appurtenances,etc.) No I (revised 04117)97i SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 61 Russells Path Marstons Mills Owner: Jim Wilimott:105 Watershed Way Marstons Mills Date of Inspection:3117199 SOIL ABSORPTION SYSTEM(SAS):x (locate on site plan,if possible;excavation not required,but may be approximated by non-intrusive methods) If not determined to be present,explain: rda Type: leaching pits,number: onel,000 gallon leach ph leaching chambers,number:nla leaching galleries,number: Na leaching trenches,number,length: nfa leaching fields,number,dimensions:nla overflow cesspool,number:rya Alternate system: rda Name of Technology:_rda Comments:(note condition of soil, signs of hydraulic failure,level of ponding, condition of vegetation, etc.) Leach pit and all components are structurally sound and fundoning properly. CESSPOOLS: (locate on site plan) Number and configuration: nla Depth-top of liquid to inlet invert: rda Depth of solids layer: rda Depth of scum layer: nla Dimensions of cesspool: rda Materials of construction: rda Indication of groundwater: nla inflow(cesspool must be pumped as part of inspection) nfa Comments:(note condition of soil, signs of hydraulic failure,level of ponding, condition of vegetation, etc.) rda PRIVY:_ (locate on site plan) Materials of construction: nla Dimensions: We Depth of solids: nla Comments: (note condition of soil, signs of hydraulic failure,level of ponding,condition of vegetation, etc.) nla pevised 0427191) SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) 01 Russells Path Marstons Mills Jim Willmott:105 Watershed Way Marstons Mills 3117198 SKETCH OF SEWAGE DISPOSAL SYSTEM: include ties to at least two permanent references, landmarks or benchmarks locate all wells within 100'(Locate where public water supply comes into house) i�d Y AA 3V A 5 AC AP d DUA e� 75 a D �3� l Pay 9 of 30 (revlaed 04127197) SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) 01 Russells Path Marstons Mills Jim Willmott:105 Watershed Way Marstons Mills 3117198 Depth of groundwater 12. Please indicate all the methods used to determine High Groundwater Elevation: Obtained from design plans on record. Observation of Site(Abutting property, observation hole, basement sump etc.) Determine it from local conditions Check with local Board of Health Check FEMA Maps Check pumping records Check local excavators, installers x Use USGS Data Describe in your own words how you established the High Groundwater Elevation.(MUST be completed) USGS maps and charts (revlsed04ft7197) Pago 10 of 10