SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION
Property Address: 23 SAMOSET RD. MARSTONS MILLS 101-112-L 32
Name of Owner NELSON MORIN
Address of Owner: C/O ED.MORGAN 442 BAY LANE CENTERVILLE MA.02632 Ilk
Date of Inspection: 9/27/99 CI oF
Name of I Ins am a DEP approved system inspector ctor:(Please Print)JOHN pursuantpursuant to Section 15.340 of Title 5(310 CMR 15.000)
Company Name: n/a
Mailing Address:
Telephone Number: nla
CERTIFICATION STATEMENT
I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true,accurate
and complete as of the time of inspection.The inspection was performed based on my training and experience in the proper function and
maintenance of on-site sewage disposal systems.The system:
X Passes The Inpection is based on criteria defined In Title V
Conditionally Passes code 310 CMR 15.303.My findings are of how the system is
Needs Further Evaluation By the Local Approving Authority performing at the time of the inspection.My Inspection does
Fails not imply any warranty or guarantee of the longgevity of the
septic system and any of Its components useful life.
Inspector's Signature: Date:9/27/99
r
The System Inspector shal submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within thirty(30)days of
completing this inspection.If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner
shall submit the report to the appropriate regional office of the Department of Environmental Protection.The original should be sent to the
system owner and copies sent to the buyer,if applicable,and the approving authority.
NOTES AND COMMENTS
THE SYSTEM PASSES TITLE V INSPECTION.RECOMMEND PUMPING THE SYSTEM EVERY TWO YEARS TO PROLONG THE SYSTEM'S
USEFULL LIFE.
revised 9/2/98 Page 1 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9/27/99
INSPECTION SUMMARY: Check A, B, C, or D:
A. SYSTEM PASSES:
I have not found any information which indicates that any of the failure conditions described in 310 CMR 15.303 exist.Any failure criteria not evaluated
are indicated below.
COMMENTS:
System passes Title V inspection
B. SYSTEM CONDITIONALLY PASSES:
Wa One or more system components as described in the"Conditional Pass"section need to be replaced or repaired.The system,upon completion of the
replacement or repair,as approved by the Board of Health,will pass.
Indicate yes,no,or not determined(Y,N,or ND).Describe basis of determination in all instances.If"not determined",explain why not.
Wa The septic tank is metal,unless the owner or operator has provided the system inspector with a copy of a Certificate of
Compliance(attached)indicating that the tank was installed within twenty(20)years prior to the date of the inspection;or
the septic tank,whether or not metal,is cracked,structurally unsound,shows substantial infiltration or exfiltration,or tank
failure is imminent.The system will pass inspection if the existing septic tank is replaced with a complying septic tank as
approved by the Board of Health.
nLa Sewage backup or breakout or high static water level observed in the distribution box is due to broken or obstructed pipe(s)
or due to a broken,settled or uneven distribution box.The system will pass inspection if(with approval of the Board of Health).
_ broken pipe(s)are replaced
obstruction is removed
distribution box is levelled or replaced
Wa The system required pumping more than four times a year due to broken or obstructed pipe(s).The system will pass
inspection if(with approval of the Board of Health):
_ broken pipe(s)are replaced
obstruction is removed
revised 9/2/98 Page 2 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9/27/99
C. FURTHER EVALUATION IS REQUIRED BY THE BOARD OF HEALTH:
Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect the public health,safety
and the environment.
1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES IN ACCORDANCE WITH 310 CMR 16.303(1)(b)THAT THE SYSTEM IS
NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT ThE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT:
Cesspool or privy is within 50 feet of surface water
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh.
2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH(AND PUBLIC WATER SUPPLIER.IF ANY)DETERMINES THAT THE SYSTEM IS
FUNCTIONING IN A MANNER THAT PROTECTS THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT:
The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a
surface water supply.
The system has a septic tank and soil absorption system and the SAS is within a Zone I of a public water supply well.
- The system has a septic tank and soil absorption system and the SAS is within 50 feet of a private water supply well,
- The system has a septic tank and soil absorption system and the SAS is less than 100 feet but 50 feet or more from a
private water supply well,unless a well water analysis for coliform bacteria and volatile organic compounds indicates that the
well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less
than 5 ppm,Method used to determine distance nla-(approximation not valid).
3) OTHER
nLa
revised 9/2/98 Page 3 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9/27199
D. SYSTEM FAILS:
You must indicate either"Yes"or"No"to each of the following:
I have determined that one or more of the following failure conditions exist as described in 310 CMR 15.303.The basis for this determination is
identified below.The Board of Health should be contacted to determine what will be necessary to correct the failure.
Yes No
X Backup of sewage into facility or system component due to an overloaded or clogged SAS or cesspool.
X Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool.
X Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool.
X Liquid depth in cesspool is less than 6"below invert or available volume is less than 1/2 day flow,
X Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).
Number of times pumped nLa.
X Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater elevation.
X Any portion of a cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply.
X Any portion of a cesspool or privy is within a Zone I of a public well.
X Any portion of a cesspool or privy is within 50 feet of a private water supply well,
X Any portion of a cesspool or privy is less-than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality
analysis.If the well has been analyzed to be acceptable,attach copy of well water analysis for coliform bacteria,volatile organic ompounds,
ammonia nitrogen and nitrate nitrogen.
X The liquid level in the SAS is over the invert pipe,is in Hydraulic Failure.
E. LARGE SYSTEM FAILS:
You must indicate either"Yes"or"No"to each of the following:
The following criteria apply to large systems in addition to the criteria above:
_ The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a significant threat to public health and
safety and the environment because one or more of the following conditions exist:
Yes No
X the system is within 400 feet of a surface drinking water supply
X the system is within 200 feet of a tributary to a surface drinking water supply
X the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or a mapped Zone II of a public
water supply well)
The owner or operator of any such system shall upgrade the system in accordance with 310 CMR 15.30412).Please consult the local regional office of the
Department for further information.
revised 9/2198 Page 4 of 11
I
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECKLIST
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9/27/99
Check if the following have been done:You must indicate either"Yes"or"No"as to each of the following:
Yes No
X Pumping information was provided by the owner,occupant,or Board of Health.
X None of the system components have been pumped for at least two weeks and-the system has been receiving normal flow rates
during that period.Large volumes of water have not been introduced into the system recently or as part of this inspection.
X As built plans have been obtained and examined.Note if they are not available with N/A,
X The facility or dwelling was inspected for signs of sewage back-up.
X The system does not receive non-sanitary or industrial waste flow.
X The site was inspected for signs of breakout,
X All system components,excluding the Soil Absorption System,have been located on the site.
X The septic tank manholes were uncovered,opened,and the interior of the septic tank was inspected for condition of baffles
or tees,material of construction,dimensions,depth of liquid,depth of sludge,depth of scum.The size and location of the Soil Absorption
System on the site has been determined based on:
X Existing information,For example,Plan at B4O,H,
X Determined in the field(if any of the failure criteria related to Part C is at issue,approximation of distance is unacceptable)
11 5.302(3)(b)]
X The facility owner(and occupants,if different from owner)were provided with information on the proper maintenance of
Subsurface Disposal Systems.
revised 9/2198 Page 5 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9/27199
FLOW CONDITIONS
RESIDENTIAL:
Design flow:lt0 g.p.d./bedroom
Number of bedrooms(design): 4 Number of bedrooms(actual):2
Total DESIGN flow: 441
Number of current residents:2
Garbage grinder(yes or no):NO
Laundry(separate system)(yes or no): NQ If yes,separate inspection required
Laundry system inspected(yes or no):M
Seasonal use(yes or no):.MO
Water meter readings,if available(last two year's usage(gpd): nLa
Sump Pump(yes or no): NQ
Last date of occupancy: n&
COMMERCIAUINDUSTRIAL
Type of establishment: Wit
Design Flow: Wa gpd(Based on 15.203)
Basis of design flow: Wa
Grease trap present:(yes or no):DLO
Industrial Waste Holding Tank present:(yes or no): NQ
Non-sanitary waste discharged to the Title 5 system:(yes or no):NQ
Water meter readings.if available:n&
Last date of occupancy: n&
OTHER: (Describe)
Wa
Last date of occupancy: Wit
GENERAL INFORMATION
PUMPING RECORDS and source of!information:
DLa
System pumped as part of inspection:(yes or no):NQ
If yes,volume pumped W& gallons
Reason for pumping: n&
TYPE OF SYSTEM
X Septic tank/distribution boxisoil absorption system
Single cesspool
Overflow cesspool
Privy
Shared system(yes or no)(if yes.attach previous inspection records,if any)
I/A Technology etc.Attach copy of up to date operation and maintenance contract
Tight Tank Copy of DEP Approval
Other: nLa
APPROXIMATE AGE of all components,date installed(if known)and source of information:
THE SYSTEM IS 15 YEARS OLD..
Sewage odors detected when arriving at the site:(yes or no): NQ
I
revised 9/2/98 Page 6 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9/27/99
BUILDING SEWER:
(Locate on site plan)
Depth below grade: 1,6..
Material of construction:_ cast iron X 40 PVC _ other(explain)
Distance from private water supply well or suction line: TOWN
Diameter: n&
Comments: (condition of joints,venting,evidence of leakage,etc.)
n&
SEPTIC TANK: X
(locate on site plan)
Depth below grade: V
Material of construction:X concrete_ metal_ Fiberglass _ Polyethylene _ other(explain)
n&
If tank is metal,list age Is age confirmed by Certificate of Compliance(Yes/No): MQ
nLa
Dimensions: L 8'6"H 6'7"W 4'10"
Sludge depth: J"
Distance from top of sludge to bottom of outlet tee or baffle: 3E
Scum thickness:I
Distance from top of scum to top of outlet tee or baffle:6_
Distance from bottom of scum to bottom of outlet tee or baffle: 11
How dimensions were determined: MEASURED
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,
etc.)
SEPTIC TANK AND ALL COMPONENTS ARE STRUCTURALLY SOUND RECOMMEND PUMPING SYSTEM EVERY TWO YEARS
GREASE TRAP:
(locate on site plan)
Depth below grade:
Material of construction:_concrete_ metal_ Fiberglass _ Polyethylene_other(explain)
n&
Dimensions: n&
Scum thickness: n&
Distance from top of scum to top of outlet tee or baffle:llLa
Distance from bottom of scum to bottom of outlet tee or baffle WA
Date of last pumping: nLa
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,
etc.)
nla
` revised 9/2/98 Page 7 of 11
I_
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9/27199
TIGHT OR HOLDING TANK: NO (Tank must be pumped prior to,or at time of,inspection)
(locate on site plan)
Depth below grade: nta
Material of construction:_ concrete_ metal_ Fiberglass _Polyethylene_ other(explain)
Wa ,
Dimensions: Wa
Capacity: nLa gallons
Design flow: DLa gallons/day
Alarm present: NO
Alarm level:i3ta- Alarm in working order:Yes_No_: NO
Date of previous pumping: nLa
Comments:
(condition of inlet tee,condition of alarm and float switches,etc.)
DLa
DISTRIBUTION BOX: _
(locate on site plan)
Depth of liquid level above outlet invert:n&
Comments:
(note if level and distribution is equal,evidence of solids carryover,evidence of leakage into or out of box,etc.)
IlLa
PUMP CHAMBER: NQ
(locate on site plan)
Pumps in working order:(Yes or No): NQ
Alarms in working order(Yes or No): NQ
Comments:
(note condition of pump chamber,condition of pumps and appurtenances.etc.)
Wa
revised 9/2/98 Page 8 of 11
_
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9/27/99
SOIL ABSORPTION SYSTEM(SAS): X
(locate on site plan,if possible;excavation not required,location may be approximated by non-intrusive methods)
If not located,explain:
nLa
Type:
leaching pits,number: 1000 GAL.LEACH PITW/2'STONE
leaching chambers,number: .1]La
leaching galleries,number: jiLa
leaching trenches,number,length: n&
leaching fields,number,dimensions: nLa
overflow cesspool,number: n&
Alternative system: n&
Name of Technology: ji&
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.)
THE LEACH PIT IS STRUCTURALL SOUND AND FUNTIONING PROPERLY.THE PIT HAS NOT HAD MORE THAN 6"OF WATER IN IT.
CESSPOOLS: _
(locate on site plan)
Number and configuration: Wa
Depth-top of liquid to inlet invert: n&
Depth of solids layer: n&
Depth of scum layer. n&
Dimensions of cesspool: n&
Materials of construction: n&
Indication of groundwater: n& inflow(cesspool must be pumped as part of inspection)nLa
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.)
nLa '
PRIVY: _
(locate on site plan)
Materials of construction:n(a Dimensions:n&
Depth of solids: n&
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.)
nla
revised 9/2/98 Page 9 of 11
I
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9127/99
SKETCH OF SEWAGE DISPOSAL SYSTEM:
include ties to at least two permanent reference landmarks or benchmarks
locate all wells within 100'(Locate where public water supply comes into house)
n/a
I�
I
A
M04
�
AAaa
o
AO
C a�
19
gc any
revised 9/2/98 Page 10 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 23 SAMOSET RD.MARSTONS MILLS 101-112-L 32
Owner: NELSON MORIN
Date of Inspection:9/27/99
NRCS Report name: nLa
Soil Type: nta
Typical depth to groundwater: nLa
USGS Date website visited: n&
Observation Wells checked: NQ
Groundwater depth:Shallow _ Moderate _ Deep _
SITE EXAM _ Slope
_ Surface water
_ Check Cellar
_ Shallow wells
Estimated Depth to Groundwater 12 Feet
Please indicate all the methods used to determine High Groundwater Elevation:
_ Obtained from Design Plans on record
_ Observed Site(Abutting property,observation hole,basement sump etc.)
_ Determined from local conditions
_ Checked with local Board of health
Checked FEMA Maps
_ Checked pumping records
_ Checked local excavators,installers
XUsed USGS Data
Describe how you established the High Groundwater Elevation.(Must be completed)
USGS MAPS AND CHARTS
revised 9/2/98 Page 11 of 11
LOCATION SEWAGE PERMIT NO.
Z- m o Set �cQ.
YIILAGE L
lrz fft I�
INSTA LLER'S NAME ADDRESS
�~
2 f
0 U I L D E R OR OWN ER
DATE PERMIT ISSUED
DATE COMPLIANCE ISSUED
Zit
3�
t
43Z
I; h �
h. :tp S C W13
1
No... - FRs..............................
THE COMM ONWEALTH OF MASSACHJJSETTS
BOARD OF HEALTH
2 ovm ....................OF..Barnstable .
.............. ... .. .......... ..
...............................for Mipaiial Works Tunitrurtiun ami#
JC Mt.
Application is hereby made for a Permit to Construct (X ) or Repair ( ) an Individual Sewage Disposal
System at: Marstons Mills �s
Lot #32 Ay
Loca io -Address or No.
Capricorn Rear Trust6, Falmouth Roar _H,yannis
.............. .....•. ...•.
Owner Address
w Steve Lebzl
Installer Address
Type of Building Size Lot:..........................Sq. feet
U Dwelling—No. of Bedrooms...3......................................Expansion Attic ( ) Garbage Grinder ( )
04 Other—Type of Building ranCh............. No. of persons............................ Showers (2 ) — Cafeteria ( )
a' Other fixtures ............................
'W Design Flow.........5_$..............................gallons per person per day. Total daily�flow.._......33Q...........................gallons.
�: Septic Tank—Liquid capacity 100O.gallons Length ............ Widthy...1.Q...._ Diameter................ Depth..8....._.
Disposal Trench—No. .................... Width.................... Total Length.................... Total leaching area....................sq. ft.
Seepage Pit No 1- _--- ----- Diameter ........... Depth below inlet �.......... Total leaching area.. _:..sq. ft.
z Other Distribution box ( ) Dosing tank ( )
Percolation Test Results Performed b �,ldredge Engineering............ Date...11•-25-81
Y ,a y..... . •----•...
,-a Test Pit No. 1-2...Q..._..minutes per inch Depth of Test Pit..,i2........... Depth to ground wateinXle-...S.U.00unte -
rX4 Test Pit No. 2N/A........minutes per inch Depth of Test Pit14/A........... Depth to ground water._1)/&------------- e
•---•---•--•-------------------•-•-•-----•--------................--•-•••-•..................................................................................
O Description of Soil....-----.0 ....-._. ...........10.=.A....t S.Q1a.
-----------------------------•--•------•-•-...
v ..................------•---•••••---....._2'...•-...10.•-----Died um..yellow-••sand...........................................
W 10' -- 12.'.--•_med._-•white•.•sand/traces._.of___graelno water at_ 12 '
UNature of Repairs or Alterations—Answer when applicable ......... ......... ......... ......... ......... ...............................
..--••-••••----•------------••••.......•--•-•-••••------•---•------•-------------------••------••••-•....-•-•...-•------------•---------...............................................................
Agreement:
The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with
the provisions of iITL L 5 of the State Sanitary Code—The undersigned further agrees not to place the system in
operation until a Certificate of Compliance has been issue by t e board of alth.
Signed ( ...... -• • -•---• .........Pr e s.-----
Date
Application Approved By............_.,. ...� ..............................
Date
Application Disapproved for the f ollowing reasons:... ............................... ..-....... ....... . ............. . ...._..:.....-----.------
.........................................................................................................._...............z.r•------ --- -------- ......................................
Date
PermitNo......................................................... Issued.......................................................
Date
uuA-
N r'
No......................... Film.............................
THE COMMONWEALTH OF MASSACHUSETTS
. BOARD OF HEALTH
Town_..__..................OF..Barnstabl•e N
AVVIkation for Diopoiial Workii Tonitrnrtion ".truth
Application is hereby made for a Permit to Construct (K ) or Repair ( ). an Individual Sewage Disposal
System at: Marstons Mills
..........ot...132...SaM se: F d.-,.... ... ... .-.l`l� .... ..........
Location Address or Lot No.
Capricor....................ey Trust _7. 5 Falmouth Road,t...Hyannis
.......................... •. _....
Owner Address
� -------Steve•-I,Abzl.........................•--•----••----------.............. ....._......------•----••-----------------.- ._...............--•--...,--.............--
Installer Address
d Type of Building Size Lot............................Sq. feet
U Dwelling—No. of Bedrooms...3......................................Expansion Attic ( ) Garbage Grinder ( )
pal Other—Type of Building ranch............. No. of persons............................ Showers (2 ) — Cafeteria ( )
p•l Other fixtures ......................................................
Design Flow........55..............................gallons per person per day. Total daily flow.........3.3Q...........................gallons.
WSeptic Tank—Liquid capacityl.0OQ.galIons LengtlB'6"....._ Widti k-'.IQ".. Diameter................ Depth-5.. .......
x Disposal Trench—No. .................... Width.................... Total Length.................... Total leaching area............_.......sq. ft.
Seepage Pit Nol-_____--.... _-- Diameter.._._._.___..... Depth below inlet.....�2.........._.. Total leaching area..2��......_sq. ft.
Z Other Distribution box ( ) Dosing tank ( )
'- Percolation Test Results Performed by...�Udredge Engineering............ Date...11-25_-81
Test Pit No. 1__2...Q------minutes per inch Depth of Test Pit..12.'......... Depth to ground watein011e.... no-ount er-
(i, Test Pit No. II/A.....'..minutes per inch Depth of Test PitTlA............ Depth to ground water..��A.............. e
x •--------------------------------------------------------------------------------------------------------------------------------------------•--•-----•....•.
Description of Soil..........Q-......- 2 .........1o_am...&...to-psail.........................................................................................
U
w 10'------_.12.'...-..med,--.-v�llit_�._-sandtraces...of...gravel/no--water...at_• 12'
VNature of Repairs or Alterations—Answer when applicable........... ......... ........ ..................... ......... ..................
-- ----------••--•---------•-•••-•-••-••••-••••...•-•---••--•--•---------•-------•••---•-•--•...........••--...--•--------•--••-••--•---•-------•--•--••-•-•-•••••-•••--•-••-•-•-••..:.....----•-•-----
Agreement:
The undersigned agrees to install the aforedescribed_Individual Sewage Disposal System in accordance with
the provisions of TITLZ 5 of the State Sanitary Code=The undersigned further agrees not to place the system in
operation until a Certificate of,Complianf-hT" een isp� e b and of health.
Pr s. 9 1 /83_..
Signed •------ --- ----•- _ .3� . .
Date
Application Approved BY .._ _. ..................................
Date
Application Disapproved for the following reasons---------------------------------••-•-----...-•---•-•-••--•-•----••--•-- ........................................
---•••--....•••-•-•-•-----•-•........-•--••-•--••-•--•------•----•------•-•--•--•-----•--••--•-------•-........................•-•---•--••---•---------•---•-••----•-•-••--•-•-•--••-••---•--•-•----•----
Date
I
PermitNo......................................................... Issued-.......................................................
Date
t
THE COMMONWEALTH OF MASSACHUSETTS
BOARD OF HEALTH
............T o ym.................OF.......Barnstable..............................................
(9rdifiratr of Tonytiatta
THIS IS TO CERTIFY, That the Individual Sewage Disposal System constructed (X or Repaired ( )
by.................................................Ste-ve...L ebe7 ..........In..--ll----------------------•-
Insta
at Lot-1 32-.Samose- Ra -s ra cst9? € a 9 �wit...I.- --------` �. -------------
has been installed in accordance with the provisions of TITLE 5 of The State Sanitary Code as described in the
application for Disposal Works Construction Permit No......................................... dated----------......................................
THE ISSU NCE OF THIS CERTIFICATE SHALL NOT BE/CONSTRU AS A GUARANTEE THAT THE
SYSTEMFU CTION SATISFACTORY.
LDATE.... .. . .. ..l ./-_--•••...........................•---•••--....••_.. Inspecto ....•----•--•--•----•-.......•••--•.....---..................--
THE COMMONWEALTH OF MASSACHUSETTS
�� 7T BOARD OF HEALTH
_.�.�.. T.:9tvn-........I..............O F....Barns t abl e...---.......................
No......................... FEE........................
�io�roottl orko �ono#rnr##ion rrmi�
Permission is hereby granted..................S-t-emp_.Le. e1-------------------------------...._...-•----.
to Construct (�_ or Repair ( ) an Individual Sewage Disposal S.ystgi
o Mars tons N ....
/
S4r e
as shown on the applicatiga-fy Works Construction Permit No..................... atec?53___.._......_._.._._.___ �
......................................................................................................./
Board of Health c�°t'
DATE................................................................................
FORM 1255 A. M. SULKIN. INC., BOSTON _.
- i
lec
1 AGi2 E NI i N !;�' y"
Z I
�Ci 11
Egg
4 � �
1L � e ,
3 732.
i a �
I
kA
N N
I., oIsr.64 !!
' , V
Yvvvri
.'^G;a
LEGEND CERTIFIED PLOT PLAN
EXISTING SPOT ELEVATION Ox0 %ttco€ .q _
EXISTING CONTOUR ---- O --- ROBERTJ��`('
FINISHED SPOT ELEVATION .b r eRUCE
FINISHED CONTOUR ,� ELDRED y IN
``� • x"'
APPROVED , BOARD OF HEALTH ,t +
DATE AGENT SCALES i — 3 DATE `/-13-8
LD EDGE ENGINEERING CO. IN CLIENT__.t��� I CERTIFY THAT THE PROPOSED
EGISTERE REGISTERED JOB NO. B3?5G BUILDING SHOWN ON THIS PLAN
CIVIL. LAND CONFORMS TO THE ZONING LAWS
ENGINEER SURVEYOR DR.BYt �_ OF BARNSTABLE , MASS,
CH. 8Y=
712 MAIN STREET , . �
HYANN I S, MASS. SHEET-L'0F Z 1--'DATE REG. LAND SURVEYOR
IV07-e /F E/TNER THE-5EPT/C TANK OR
EACl//NG ?/,r ARE MORE THA:"/ /2 BELO.W N
/O JsT: M 1w. :JRA OEM f� a?Q'p/A M E TER CONCR.E T� CO i/ER. ,�'`
Q'PYC P/PE 'SWAZ Z BE ORO&a.V 7 TO GRA OE.�f,v CONCRCTE M/N. P/TCN 81E.4VY CAST IRON COVER Sf/ALL DE USED
G01/ GS /B'
E/ J�F.Q FT /F/N OR/✓EyV.4 y
A :ia 2% MiN. G'ONCRE T.E
CO ✓ER CLEAN .SANG
2"LAYER
RON P/PE /boo G/IL. '�
~:d •4/PE D/ST: o 1 • • • . • • • • e •• WASHPO.57ONE
.SEPTIC TA/V/< BOJ� • • • • . • • • • • o s a a
fir. - o i • • � e • • • • • � .••� w
r:° e e • •EfFEL"l7VC ' • . 314as
• • • � � • DEFT/+/ • • • • • � • 1s%4St%ED STONE
y7/ 6p-t' i sI • • • • • . • • • • • P ,moo PRECA5T SEEPAGE
1AIV&M'T LsLEYA7/0/Vs 7�•S J�� 78 • •• • • • • • • • • • s o P/T DR EpU/W.
INEZ.RT AT Bl//LDINCr FT• ; mi IV At
INLET .SEPr.,c Ti4/VIC f�•S FT FT. O/AJW. _ �C(SFP TABULATJON�
OUTLET SEPTIC TANK T Fl.
/INLET OISTR/8t/r/ON BOX-fs.v FT. SECT/ON OF GROV VO WATER 7A0Z,6
O(/TLETD/STR/BUT'/ON BOX 8.2. FT.
I"ZEr c�ACRIMS 4:-1 �.o JET. SEAVAGE O/SA"AZ. SYSTEM
L EACH/NG P/T - Ti4 BULATlD/V
scALE
/ a /:.0" D/MlEN.S/ON A Z' hT-
DESI6/N CRITERIA : /s Ot>`lE/vsloN $ FT. ti
NUMBER OF BEDROOMS 3 D/MENS/ON .C.L°_
G4R6AGED/5,005,4�UN/rNork; SOIL LOG.
roTAL —LOM/ '4To 0.44.14PAY SOI L TEST A/ So/t 7FS7-402 . SD/L TEST. -
°s
NUMBER OF LEACH//VG p/7:3_ 98,0_�_ �`tttEK -ELEy, OATS OF SOIL TEST e ZS H3
51DE LEACHlMCr PER P/T feg.q Sig PT.
BOTTOM LZ4CN/NG PE,R P/T g�� ,fQ, �tT. o� 0-2` LOAM J RESULTS i�//TNESSED dY � �• �1���
�` PERCOLAT/ON RATE,*! Z MIA11J/VCH
TOTAL LEACH/NG •4REA ?G-7 sq FT. PENCO4A'rl0N RATE 2 MJNIINCN
RE5ERVEZE4C'N1)YCr AREA 24-2 SQ. FT
--A OF Vq �P�ZH BFMgS 2�/Z'MEDic/M
.�d . 3�`!, PG . S��``'y Ssc�, y',��`�'o•� SArf� �r+ixEp nv C
R08cRT PHILIP \^! WM4 VZL
BRUCE { WEINBER 1 //-
k� ELDRED t"n G i C
o p No. 366 O J
Rom° t ��^<C'�STER�� ELDREDGEENGINEERING G'O,/NC.
�H1) s yc, /O A�i BG,o 71Z /► A//V ST. , AlYR"Alls, ",QSS',
SUR L4fff No GRov vo kv,4TeR ENCOUNTERED CL/ENT: ►✓Ct�r D,gTE 3
Q GROUND Lti/ATER AT ELEI/ _
.JOB /Vo!&3ZC6 SHEET Z^OF 2