Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0577 WHISTLEBERRY DRIVE - Health
577 WHIS'TLEBERRY DRIVE,M. MILLS A= 061 046 i , / jibCommor�weatth of Massachusetts John Grad Executive Office of EmArom-ental Affairs D.E.P. Title V Septic Inspector Department of P.O. Box 2119 Environmental Protection Teaticket,MA02536 (508) 564-6813 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION Ap Cc R Property Address: 577 whistleberry Marstons Mills Address of Owner: 7 of Aq 2 19�J Date of Inspection:3121197 (If different) y g Name of Inspector:John Graci Bishop Th�E ST Company Name,Address and Telephone Number: CERTIFICATION STATEMENT -� I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true,accurate and complete as of the time of inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. The system: X Passes This inspection is based on criteria defined In Title V Conditionally Passes code 310 CMR 15.303.My findings are of how the system is Needs Furt r Evaluation 8 the Local Approving Authority performing at the time of the Inspection.My Inspection does Y PP 9 tY not Imply any warranty or guarantee of the longevity of the Fails septic system and any of its components useful life. r Inspector's Signature: / ✓� Date: 3130197 The System Inspector shall submit a copy of this inspection report to the Approving Authority within thirty(30)days of completing this inspections. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the Department of Environmental Protection. The original should be sent to the system owner and copies sent to the buyer,if applicable and the approving authority. INSPECTION SUMMARY: Check A, B,C, or D: A] SYSTEM PASSES: X I have not found any information which indicates that the system violates any of the failure criteria defined as in 310 CMR 15.303. Any failure criteria not evaluated are indicated below. B] SYSTEM CONDITIONALLY PASSES: One cr more system components need to be replaced or repaired. The system,upon completion of the replacement or repair,passes inspection. Indicate yes no,or not determined(Y, N,or ND). Describe basis of determination in all instances. If "not determined", explain why not.) The septic tank is metal, cracked,structurally unsound,shows substantial infiltration or exfiltration,or tank failure is imminent. The system will pass inspection if the existing septic tank is replaced with a conforming septic tank as approved by the Board of Health. (revised 11115161) One Winter Street • Boston,Massachusetts 02108 e FAX(617)556-1049 . Telephone(617)292-5500 1 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 577 Whisdeberry Marstons Mills Owner: Bishop Date of Inspection:3121197 _ Sewage backup or breakout or high static water level observed in the distribution box is due to a broken, settlad or uneven distribution box. The system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced _The system required pumping more than four times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed C] FURTHER EVALUATION 15 REQUIRED BY THE BOARD OF HEALTH: _ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect the public health, safety and the environment. 1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES THAT THE SYSTEM IS NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh. 2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH(AND PUBLIC WATER SUPPLIER, IF APPROPRIATE)DETERMINES THAT THE SYSTEM IS FUNCTIONING IN A MANNER THAT PROTECT THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT: _ The system has a septic tank and soil absorption system and is within 100 feet to a surface of water supply or tributary to a surface water supply. The system has a septic tank and soil absorption system and is within a Zone 1 of a public water supply well. The system has a septic tank and soil absorption system and is within 50 feet of a private water supply well. _ The system has a septic tank and soil absorption system and is less than 100 feet but 50 feet or more from a private water supply well,unless a well water analysis for coliform bacteria volatile organic compounds indicates that the well is free from pollution for that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal or less than 5 ppm. 3) OTHER D] SYSTEM FAILS: _ 1 have determined that the system violates one or more of the following failure criteria as defined in 310 CMR 15.303. The basis for this determination is identified below. The Board of Health should be contacted to determine what will be necessary to correct the failure. Backup of sewage in facility or system component due to an overloaded or clogged SAS or cesspool. Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged cesspool. SAS is in hydraulic failure. (revised 11115195) 2 f SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(continued) Property Address: 577 WhlstleberryMarstons Mills Owner: Bishop Date of Inspection:3121197 D] SYSTEM FAILS(continued) Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool. Liquid depth in cesspool is less than 6"below invert or available volume is less than 1/2 day flow. Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Numbers of times pumped Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater elevation. Any portion of a cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. Any portion of a cesspool or privy is within a Zone 1 of a public well. Any portion of a cesspool or privy is within 50 feet of a private water supply well. _ Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. If the well has been analyzed to be acceptable,attach copy of well water analysis for coliform bacteria,volatile organic compounds, ammonia nitrogen and nitrate nitrogen. E] LARGE SYSTEM FAILS: The following criteria apply to large systems in addition to the criteria: _ The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a significant threat to public health and safety and the environment because one or more of the following conditions exist: the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area (IWPA)or a mapped Zone 11 of a public water supply well) The owner or operator of any such system shall bring the system and facility into full compliance with the groundwater treatment program requirements of 314 CMR 5.00 and 6.00. Please consult the local regional office of the Department for further information. (revised 11/15195) 3 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECLIST Property Address: 577 Whistleberry Marstons Mills Owner: Bishop Date of Inspection:3121197 Check if the following have been done: x Pumping information was requested of the owner,occupant,and Board of Health. X None of the system components have been pumped for at least two weeks and the and the system has been receiving normal flow rates during that period. Large volumes of water have not been introduced into the system recently or as part of this inspection. ►vaAs built plans have been obtained and examined. Note if they are not available with N/A. X The facility or dwelling was inspected for signs of sewage back-up. X The system does not receive non-sanitary or industrial waste flow. X The site was inspected for signs of breakout. X All system components,excluding the Soil Absorption System,have been located on the site. X The septic tank manholes were uncovered,opened, and the Interior of the septic tank was Inspected for condition of baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge,depth of scum. X The size and location of the Soil Absorption System on the site has been determined based on existing information or approximated by non-intrusive methods. X The facility owner(and occupants,if different from owner)were provided with information on the proper maintenance of Sub- Surface Disposal System. (revised 11/15195) 4 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 577 Whlsttebeny Marstons Mills Owner: Bishop Date of Inspection:3121197 FLOW CONDITIONS RESIDENTIAL: Design flow: 330 gallons Number of bedrooms: 3 Number of current residents: 2 Garbage grinder(yes or no): No Laundry connected to system(yes or no): Yes Seasonal use(yes or no): No Water meter readings,if available: nla Last date of occupancy: nla COMMERCIAL/INDUSTRIAL: Type of establishment: n1a Design flow:0 gallons/day Grease trap present:(yes or no) No Industrial Waste Holding Tank present:(yes or no) No Non-sanitary waste discharged to the Title 5 system:(yes or no) No Water meter readings,if available: nla Last date of occupancy: rda OTHER: (Describe) nla Last date of occupancy: GENERAL INFORMATION PUMPING RECORDS and source of information: System has not been pumped In the last two years. System pumped as part of inspection: (yes or no)Yes If yes,volume pumped: 2000 gallons Reason for pumping: Maintenance. TYPE OF SYSTEM X Septic tank/distribution boxtsoil absorptions system Single cesspool Overflow cesspool Privy Shared system(yes or no) (if yes,attach previous inspection records,if any) Other(explain) APPROXIMATE AGE of all components,date installed(if known)and source information: 12 years Sewage odors detected when arriving at the site:(yes or no) No (revised 11115195) 5 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 577 Whlstieberry Marstons Mills Owner: Bishop Date of Inspection:3121197 SEPTIC TANK: X (locate on site plan) Depth below grade: r Material of construction:X concreate_metal_FRP_other(explain) Dimensions: L 8'6'H 5'7"W 4'10' Sludge depth:4' Distance from top of sludge to bottom of outlet tee or baffle: 23' Scum thickness:V Distance from top of scum to top of outlet tee or baffle:6' Distance form bottom of scum to bottom of outlet tee or baffle: 17" Comments: (recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity, evidence of leakage,etc.) Septic tank and all components are structurally sound.Recommend pumping system every year for maintenance. GREASE TRAP: (locate on site plan) Depth below grade: n1a Material of construction: _concrete_metal_FRP_other(explain) Dimensions: nla Scum thickness:nla Distance from top of scum to top of outlet tee or baffle:nia Distance from bottom of scum to bottom of outlet tee or baffle:nla Comments: (recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity, evidence of leakage,etc.) nla (revised 11115195) l3 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 577 Whlstleberry Marstons Mills Owner: Bishop Date of Inspection:3121.►97 TIGHT OR HOLDING TANK: (locate on site plan) Depth below grade: n1a Material of con struction:_concrete_metal_FRP_other(explain) Dimensions: n1a Capacity: n1a gallons Design flow: n1a gallons/day Alarm level: n1a Comments: (condition of inlet tee, condition of alarm and float switches,etc.) nla DISTRIBUTION BOX: (locate on site plan) Depth of liquid level above outlet invert: nla Comments. (note if level and distribution is equal, evidence of solids carryover, evidence of leakage into or out of box etc.) nla PUMP CHAMBER: (locate on site plan) Pumps in working order:(yes or no) Comments: (note condition of pump chamber,condition of pumps and appurtenances, etc.) n1a (revised 11115155) 7 SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 577WhistleberryMarsionsMilis Owner: Bishop Date of Inspection:3121197 SOIL ABSORPTION SYSTEM(SAS):X (locate on site plan,if possible;excavation not required,but may be approximated by non-intrusive methods) If not determined to be present,explain: Na Type:: leaching pits, number: 1,000 gallon leach pit leaching chambers,number:n1a leaching galleries,number: n1a leaching trenches,number,length: nla leaching fields,number,dimensions:n1a overflow cesspool,number:n1a Comments:(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation, etc.) The leach pft is structurally sound and functioning property,It had 4'of water in it. CESSPOOLS: (locate on site plan) Number and configuration: n1a Depth-top of liquid to inlet invert: n1a Depth of solids layer: n1a Depth of scum layer: n1a Dimensions of cesspool: n1a Materials of construction: n1a Indication of groundwater: n1a inflow(cesspool must be pumped as part of inspection) nla Comments:(note condition of soil,signs of hydraulic failure,level of ponding, condition of vegetation,etc.) nla PRIVY: (locate on site plan) Materials of construction: n1a Dimensions: n1a Depth of solids: n1a Comments. (note condition of soil, signs of hydraulic failure,level of ponding, condition of vegetation, etc.) n1a (revised 11/151.95) 8 ` SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 577 Whistlebeny Marstans Mills Owner: Bishop Date of Inspection:3121107 SKETCH OF SEWAGE DISPOSAL SYSTEM: include ties to at least two permanent references landmarks or benchmarks locate all wells within 100' P Gcie-ye ILI A O g 4A � I3g ^�h DEPTH TO GROUNDWATER Depth to groundwater:12 feet method of determination or approximation: USGS Maps and Charts (revised 11115195) 9 LOCATION#IX)X SEWAGE PERMIT NO VILLAGE I N S T A LCER'S NAME ADDRESS AVCL ® U I L D E R OR OWVER )E / Y DATL_E PERMIT ISSUED DATE COMPLIANCE ISSUED 12- �— j t f. 'd 13 y. Wei N&,f2 o.... Fps. ................ THE COMMONWEALTH OF MASSACHUSETTS BOAR® OF HEALTH ........ .. ........................OF.....................-.... .-........ Appliration for Uiipar i al Works Tonstrnrtinn rrnnit Application is hereby made for a Permit to Construct (4,1 or Repair ( ) an Individual Sewage Disposal System at: ....................• .. ....------........._------ � cation- dress , or Lot No. .........L O..r's'!r ........ Lek/E�. .......................... s�{�J...W!tcQfel f'--••--... Owner /� Address a ADM a':0;.%2C!FTfoN.....&A n.................... ................... ................................................ Installer Address Type of Building Size Lot.................... .....Sq. feet t U Dwelling—No. of Bedrooms...... .................................Expansion Attic ( ) Garbage Grinder ( ) '4 Other—Type e of Building ............. No. of ersons.....__._ � YP g --------•------ P �----------------- Showers (a.) Cafeteria ( ) dOther fixtures -----------------------------------------------------------------------------•-•----..... ........... W Design Flow............................................gallons per person per day. Total daily flow........... Q......................gal Ions. WSeptic Tank—Liquid capacity-517...gallons Length................ Width...10....... Diameter---------------- Depth.... ....... x Disposal Trench—No..................... Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No--------------------- Diameter.................... Depth below inlet.................... Total leaching area..................sq. ft. Z Other Distribution box ( ) Dosing tank ( ) Percolation Test Results Performed by.......................................................................... Date........................................ Test Pit No. 1................minutes per inch Depth of Test Pit.................... Depth to ground water........................ 44 Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ 9 •---•-••--•-•----------•---------••------------------•------------...-----------.......---•--------.......................................................... 0 Description of Soil........................................................................................................................................................................ V --------------------•-----•-•---•-----......-•---------------•-----------------•-•----•-----------------•---------------------•------------•---•-----------------------•--------------•----•---------••- UW -•-•---•-----------------------•--------•••-•------------••----•••......•------------•---------•-•••-----•-----------•------•----••--------••--•---••--••••--------------•-------••----------•--.--.•-- Nature of Repairs or Alterations—Answer when applicable................................................................................................ -----------------------------------------------------------------------------------------------------------•-•---------------------------------------------------------•--••-••--••--------------------- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Sanitary Code— e undersigned further agrees not to place the system in operation until a Certificate of Compliance has be iss y the board of th. ned .......... ._. .. �---- Die Application Approve Fthe ... ................... 6-_ ........... Date Application Disapproved ollowing reasons------------------------------------------------------------=-------------------•----------..Da e............- ........................•--...••----......•-------------•••---------------•---•----------------••----------------------------•---•••----••---------•-------•---------•--•----••--•---•••-•----••-------- Date PermitNo......................................................... Issued....................................................... Date w Noa::__-- C?..... Fxs............._............ _ THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH -•------ ......................OF..........................---...........--------------........------....... n ..... Applirati for Disposal Works Towitrurtion amit Application is hereby made for a Permit to Construct (&/) or Repair ( ) an Individual Sewage Disposal System at: ....��t- &1mic I. ...... !'dam 40 7"- --..... ... ------......•••............... ..•-••--....._....-•••----•---.._....----•-.-....._•----•-- ocation..Address ��� or Lot No. �a .........l S�t�l - - ...�........� !St/D/© ...............................+3F ..5 ......I ....'�___.N.n��r�.� .... ---•----.....•-•-------- Owner ,p Address ------•..................................•---•.. Installer Address UType of Building Size Lot............................Sq. feet Dwelling—No. of Bedrooms...... .................................Expansion Attic ( ) Garbage Grinder ( ) Other—T e of Building No. of persons _ a YP g -••-----•---.._._---•---•--- P -----•------•-•-• Showers (�:) — Cafeteria ( ) Otherfixtures --------------------------------------------•---------•----••--------•-•--•••---••-------._.......•-•-•-------------.......-----------...--•---•----- W Design Flow............................................gallons per person per day. Total daily flow.__...._` ................................gallons. WSeptic Tank—Liquid capacity:M...gallons Length................ Width._ ....... Diameter._._--_.-___-__• Depth........... x Disposal Trench—No. .................... Width.................... Total'Length.................... Total leaching area....................sq. ft. 3 Seepage Pit No..................... Diameter.................... Depth below inlet.................... Total leaching area..................sq. ft. Z Other Distribution box ( ) Dosing tank ( ) Percolation Test Results Performed by-•---•---•...--•-•-•••-----------•-••-•--•••--•--••------------------•-•- Date ..... Test Pit No. I................minutes per inch Depth of Test Pit..:.____._.......... Depth to ground water................:....... 44 Test Pit No. 2................minutes per inch Depth=of Test Pit..._____..._...._... Depth to ground water........................ E`-....... ::...............................•--•.......................................................... 0 Description of Soil.......................................................-' =- U .............................-...... ....._...--•----`.................................................................-.......................................................-................... ------------------------------------------------------------------......................... ,;-----------------------------------•---------.....--------------------•-------------......_.._------ U Nature of Repairs or Alterations—Answer when applicable................................................................................................ --------------•----•------•--.....-•-•-----•-------------------•--•-••-----•--...--••-------------••-----......---------•--------------------------...-----....--••-•••-••-----...-••---•------ Agreement: The undersigned agrees to install;-the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TIT1E 5 of the State Sanitary Code— e undersigned further agrees not to place the system in operation until a Certificate of Compliance r has be �ilsse/d'V�Ily the boa d o�"&Tlth- r �t Application Approve ..�_....._.. •-_ --•----•----•----------------•--------.....----•-----..........---------- _ -- --------------- Date Application Disapproved he following reasons:................................................................................................................ ----------- -------- •---------- _-------------------------- •---------------------- ---------------------- ------------- -__------------------------------------------------------------ ------------- Date PermitNo.---...........-......................................... Issued..............•--------------..._..•---•--....•-•-----•- Date THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH ..........................................OF.......................................M.....M....................................... Trr#ifiratr of Toutph aurr - T,- IS IS T+�CERTIFY, That the Individual Sewage Disposal System constructed ( or Repaired ( ) by-.< --- ... ` -------------------------------------------------------------------------•---•----•-•-------•••----••- �,,�'" Installer has been installed in accordance with the provisions of T 5 of The State Sanitary Code as described in the application for Disposal Works Construction Permit No... .... .............. dated................................................ THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUE® AS A GUARANTEE THAT THE SYSTEM WILL FUNCTION SATISFACTORY. � `-` y v i...... Inspector :: DATE....................................••••----•••__--•- ......................................................... THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH �Y S'Zv ...........................................OF.......................-.................................................... �^ Na......................... FEE.:..._........... _...... �� ���� �]Rkt��l�r$iYtlt P�attt� Permission is ereby granted........... v - : .... f to Construct ( f' air tan 8ua1`_Se �a °is p sal System Street as shown on the application for Disposal Works Construction P N- ............. Dated.......................................... /� ... ..................•----•---------------......-------•-----••------••--•--••-•---._ 7-/Lj—6(^ �,a�"'� Board of Health DATE ......---•...............j--•--_--- FORM 1255 A. M. SULKIN, INC., BOSTON 20 " �F /. A 43,SL.o s.F mi VJ - 1 -ST-LE= F-:�,,-- IJATM� I./I- 00 �A6E.GF p,4�/EAn�r..rT 159.Ica Kce=-FNI, u0 v ��O�fj .TaPor=Rya cxrr 1 "� G^RAC`'T5,PAVMMMiJT 4`.� 49 ' O I zi - 1 � m re. 0' pN iJ, V ` 1 '.;L1 P'r J n 9 F) p�Orr Q�t�D'� 2.-FI.S 2 S � L a7 c..9 a EX ISn►J( EL-vA-noI,1 8e ec rrau�L �e�,uw� PB�R D PLOT PLAIN D E..E,A-nc i 9L Lr�7 La 2s 114 APPPahjMD, SAD aF' 4eAur-1 a4'rE A6ENT _._.. SC41•.E: l � = �� DATA% �• I �,a4 cL16�.1r: f3�5rk�P I W EBY cegm:Y TPATTNE PRc>R�D M �LLtS SvQa/EYIaIG, I� �pglJ° a4-24 BUILNU6 Sf-Ioww od 7WIS PLAT-1 2q MUSK.PI=ET LAje CoFflMS To TWo►JIw6 LAWS E, MASS., 02lo3�L �Q•BY Q uQ F_ 'lof BAaWSTABLE, MASS. C�L1T�tR/Il..L SLlEET I aF 'L CArE -RFJfl LAUD 5v4vE-AMA F 1=1THaR ,r.4E Sa PT IG Tfvt v- c k LFAc t-I I N 6 PIT h�La= MvR� TI-a A+u l 2" C3eww A 24'"D I P2- • / 4" PVC PIPS _ �AL-L l3B BRc WT "Ta GRADS ( gypIva=WAYS. �j cc--Ic z -rfa I QEr x�r P•— A w M—,r A H EAw Derr/cA-zr 1 Rc�I c�vl=R) / M it-J. Pi-r<"� EL= IOI.S ,�cd,iERs � PcR FT. ) r V t • A / G RAt)=- COS/!=!Z _ GL)=�41.f 5A+J D uSED ►w 1N4CKFiLL Llc�ID L ava L . j ._�n LAB�cF �e•- 3�e„ cr1 nnuE—( A51•�1ED S�'tauE I (2ps r PrP� i w � I�00 ° ° M 11-J. Pr T4� GAL. ° . � A" PEt2 f=T. �Ai'lG TAI-IfL FIST. , • o ° 1 � EFFECT"IvE � e • - 3�4- - � /�'1-�� CEPT1-1 - - . ,h- WP6t IED STc�I-tG s O t o • - . e • 1 - o ° o ° o - o ° 4--71 b/D 0 1 I . • . . . r - PPEx--AsT SEEPAGE -76 G' Q o 0 1 - 0 0 0 0 0 . - - prr QQ F4tJAa� e I rJ�J E Q_T AT B lJ I L b t l.j[SD --1�.Cy FT. 49 C� /D � � Pr: D/A M. � �L=G1.1•o 1 N LET 5>=Prat TA►-1� 9g,3 FT- a� FT. DtAM. _ C �g� TAB�ATOt.I� oLrrLr---r SE Pnc TA,.1� 9B. I FT. _ I W CUT D ISTQ I Px fi10�-► BOX <i-i.9 FT• 5 `t- F G RautJ D wATE R i7sBL7F-- a.11t�T DrST(ZI BLJr1c1-a B—w 9-1-7 FT Sew A G 1= DISPOSAL S TD M I I-I LET LEAr--t-1 to6 PIT S,o FT. LEA 1 oem PIT DE3l6tJ GK ITa=I�I� �cA� : 1/4I a •• DlM1=►Y�tosJ A 3 Pr. D t atENSI d+-1 B C. FT. rJuM R. 2 of E�D�c�xn5 3 D l m eii slow C 4- FT. • GARi3AGE >sP<=AL-Lg-jr r >Jo+�t- ` t L LOG ToTA L ES`n NI A'TE-:D FLOW 330 6AL. IDAY Sc r L TEST IJ= I SO(L" PST W 2 1 L TI=ST L Wut,ABE-P- of SAG-Wf. PtT> I E 4 T=-L • (aA7E--- of SotL7E-Sr MA-acH S , 1954 SIDE L.E A---►-i l l_t6 PER. PIT 10B.S Sc�. Fr. LaA xA sa RE`x+LTS^¢ Q./ED �� J Q / J R co B I BpT74:3M LE ASH i wb Pc-:R AT Z B-5 45c�,. FT• fi so L 2AT8 Qlt i aEsg na I u /I ucr4 TOTAL LE-AcHwe. /t2�A 2�-l.0 5c�. PT. 2-4' ME ;L m 2,4TE I..rs ,L TH^N M ILJ/ luc+-4 {2ESEk� L.EfGI-It1.6 '�Co-1.o SL�. fT P�GcvNs/w0 2.0 4 col McD.GRAVEL ' 3�4. 0 Of �qsS �0� G ME ) LaT 4,2) -n . Wi-4ISTL.EE—EvP-a2 N-Ir J L.1 ,HT- AAK-S I Cl���� AA I L-LS -P D 0 LL 15 5c�2vr=-ll►.l i�I c.. OtiTta�`? +�th1I,rII E L >31.Q IL�I M Er LA/1E, 4:a I- P-vrl1JH, MAS5 GRcnw44b f' Q :r s Pc�uD�.vA?�P.a a=I_ + GL>EI,tr f3 -b PH a�f�T1= : ro. I I• e 4 �013 us: g 4,24 5�T 2 cF 2