Loading...
HomeMy WebLinkAbout0028 DEER JUMP HILL - Health j i S DEERJUMPMIL•L RD. k ; ��VEST BARNSTABLE, 1y ` A =`133, 041 L. i I ,TO`WN OF BARNSTABLE LOCATION J)'l/ SEWAGE VILLAGE _Z ' SIM'k— ASSESSOR'S MAP & LOT j 3 3-6'Zl 1 INSTALLER'S NAME & PHONE NO. A & B CANCO 775-6264 -SEPTIC TANK CAPACITY� a� LEACHING FACILITY:(type)/7,Q�i%"�� NO. OF BEDROOMS PRIVATE WELL OR PUBLIC WATER BUILDER OR OWNER y C34lll114 DATE PERMIT ISSUED: 02 DATE COMPLIANCE ISSUED: VARIANCE GRANTED: Yes No 91 , ' • 7u y � r4 . No. �'' ° ! Fee b/ _. THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: Yes PUBLIC HE4TH DIVISION -TOWN OF BARNSTABLE. MASSACHUSETTS 01ppYication for M.5po5al *p5tem Congtrurtfon Vermit Application for a Permit to" truct( )Repair( )Upgrade( )Abandon( ) ❑Complete System ❑Individual Components Location Address or Lot No. 2 r UYh n /{� „( O wne�natge y ir�ess and Tel.No. Assessor's Map/Parcel 133 _ L// �' �P.r•fh/ l�• '�U Sr,� trv�( Installer's Name,Addrelhaa '�1.WOO Designer's ame,.Wdress and Tel.No. 3500M++ain Street � �( W.Yarmouth MA 02673 T�pe of Building: Dwelling No.of Bedrooms 3 Lot Size sq. ft. Garbage Grinder( ) Other Type of Building Ze 5 No.of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow 33a gallons per day. Calculated daily flow 36 S gallons. Plan Date t'n -a- R 7 Number of sheets t' Revision Date Ai/ Title Si � 2 Size of Septic Tank loon Type of S.A.S. f Description of Soil Nature of Repairs or Alterations(Answer when applicable) N�f 61U Date last inspected: DESIGNING ENGINEER MUST SUPERVISE Agreement: INSTALLATION AND CERTIFY IN WRITING THE SYSTEM WAS INSTALLED IN STRICT The undersigned agrees to ensure the construction and mainteAt%0F(dJ44,g ffq*p d on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi- cate of Compliance has been issued by this Bo Ntalth. Signed Date to Application Approved b Date Application Disapproved for the following reasons r Permit No. Date Issued '_ THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE, 'tA UST SUPERVISEI ITIO TIFY IN WRITING Certif irate # TALLED IN STRICT 4upgraded THIS IS TO CERTIFY,that the On-site Sewage Disposal System Constructed( )Repaired ( ( ) Abandoned( )by 6 d at i ,94 has been constructed in accordance 01 with the provisions of Title 5 and the for Disposal System Construction Permit No. V 40ated " Installer Designer The issuance of this permit shall not be construed as a guarantee that the system will function as designed. Date Inspector !•J ' Fee J Cj THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: Yes PUBLIC HEALTH DIVISION - TOWN OF BARNSTABLEs MASSACHUSETTS ZIppricatiou for Migoal *p5tem Construction Permit Application for a Permit to truct( )Repair( )Upgrade( )Abandon( ) El complete System ❑Individual Components Location Address or Lot No. , / e r U J� q ; / Owner's Name, ress and Tel.No. Assessor's Map/Parcel 33 — y � � Installer's Name,Address,*&1$oCANCO esie `Name, `dress and Tel.No. 350 Main Street W. Yarmouth, MA 02673 J 9 D Type of Building: Dwelling No.of Bedrooms 3 Lot Size sq. ft. Garbage Grinder( ) Other Type of Building !2 c 5 No. of Persons ; Y Showers( ) Cafeteria( ) Other Fixtures r Design Flow 336 gallons per days Calculated daily flow " a'�S� gallons. Plan Date r'n 'j - 9 h Number of-,'sheets Revision Date /Y Title S;tc 5",Ipaer 7 Size of Septic Tank loon Type of S.A.S. 1 1 ,'14 f A4o r .� cDescription of Soil y Nature of Repairs or Alterations(Answer when applicable) Date last inspected Agreement: The,undersigned agrees to ensure the construction�apd maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of thF Environmental Code and not to place the system in operation until a Certifi- cate of Compliance has been issued by this Bo Zfith. Signed 1 {.;�' Date -I� - /F-F Application Approved b Date '00. '� sr Application Disapproved for the following reasons r Permit No. �. Date Issued I r THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE, MASSACHUSETTS Certificate of Compliance THIS IS TO CERTIFY, that the On-site Sewage Disposal System Constructed ( ) Repaired( )Upgrided( ) Abandoned( )by at. / _v /��/� / /�1 has been constructed in accordance wiih the provisions of Title 5 and the for Disposal System Construction Permit No. ' I dated i 0/1 ' f Installer Designer The issuance of this permit shall not be construed as a guarantee that the system will function as designed. Date Inspector No. Fee J o THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION - BARNSTABLEs MASSACHUSETTS '=i!5Poga1 *p5tem Construction Vermit Permission is hereby granted to Construct( )Re air( )Upgrade(t/�bandon (, ( ) System located at / P� ? �/� �. ��1�r/,us 14 and as described in the above Application for Disposal System Construction Permit. The applicant recognizes his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided:Construction must be completed within three years of the date of thiog rmit. Date: 4 '� /9^ / 6 Approved �" !::f ✓ ,' .ti Health Complaints 07-Aug-02 Time: 12:50:00 PM Date: 7/31/02 Complaint Number: 3589 Referred To: LEE MCCONNELL Taken By: karyn dace Complaint Type: ARTICLE XXXIX HAZARDOUS WASTE Article X Detail: Business Name: Number: 104 Street: Deer Jump Hill Village: WEST BARNSTABLE Assessors Map-Parcel: 132/041 Complaint Description: Owner running business out of home, makes false teeth in his home, complainant is concerned about use and disposal of plastic/ polymer materials in this residential area. Would like a follow up please. Actions Taken/Results: Lm investigated complaint 08/01/2002, no one was home. Spoke with Douglas Bean (508-362- 1120 or 508-362-5042- LAB) 08/05/2002 regarding complaint. Mr. Bean explained he was running a small business out of his home. He is a certified dental technician, he makes crowns out of gypsum and gold. He installed a gravity plaster trap to filter particles before the wastewater enters his on-site septic system. Mr. Bean does not have a business certificate or permission from ZBA to run business out of his house. No concerns about illegal dumping of hazardous waste. Investigation Date: 8/5/02 Investigation Time: 1:00:00 PM 1 Health Complaints 07-Aug-02 Time: 12:50:00 PM Date: 7/31/02 Complaint Number: 3588 Referred To: LEE MCCONNELL Taken By: karyn dace Complaint Type: ARTICLE XXXIX HAZARDOUS WASTE Article X Detail: Business Name: Number: 100 Street: Indian Spring Village: WEST BARNSTABLE Assessors Map-Parcel: Complaint Description: House number unknown - pink house, only one on Indian Spring. Ned Gibbons (owner) is running a printing business out of his house. Complainant is concerned over plastics, solvents, inks etc being used & method of disposal. There are several employees working in and out of the house for a while, the number of staff is increasing. Is this properly zoned? Would like a follow up , please. Actions Taken/Results: Lm investigated complaint 8/1/2002 @11:OOAM. LM spoke with Edward Gibbons (508-362-2196) regarding complaint. Mr. Gibbons explained that he was running a small family run business out of his home but not a printing business. Mr. Gibbons assembles pre- made rubber stamps, does some engraving and magnetic signs. Lm walked thru house, observed no hazardous waste or toxic materials in home, besides household hazards (ie, cleaning products, bleach, etc...) Talked to building and clerks office, Mr. Gibbons does not have a business certificate or permission from ZBA to run business out of home. 1 Health Complaints 07-Aug-02 Investigation Date: 8/1/02 Investigation Time: 11:00:00 AM 2 ASSESSORS MAP: 133 TZ-1) T HOLE LOGS NOTES: PARCEL: 41 _ £` 1. VERTICAL DATUM: ASSUMED FROM QUAD (NGVD +/-) et FLOOD ZONE: C ENGINEERR: RICHARD FAIRBANKS, P.E. 2. MUNICAPAL )PATER IS NOT AVAILABLE. WITNESS: J. JACOBY (P# 3274 & 3275) 3. SCHEDULE 40 - 4 PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. DATE: -2-8 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-20 N PERCOLA7_;O1P`.B#E j, < 2 MIN/IN LOADING SPECIFICATIONS. 5. PIPE PITCH = 114" PER FOOT, (UNLESS NOTED OTHERWISE). TH-1 384 T H-z 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. LOCUS ELEV. ELEV. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE LOAM & SUBSOIL LOAM & SUBSOIL USE OF A GARBAGE DISPOSAL. � so" sss 24" I 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE CLEAN MEDIUM .SAND CLEAN MEDIUM STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL LOCATION MAP & FINE GRAVED & FINE SAND _ HEALTH REGULATIONS. LOT 13 59,464 ± S.F. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR (1.37 ± AC.) TO CONSTRUCTION. 2 6. 00, 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3.0. 11. EXISTING LEACH PIT TO BE PUMPED AND FILLED WITH SAND 1ss„ I OR REMOVED. 12. DESIGN ENGINEER TO CONFIRM SUITABLE SOIL CONDITIONS AT TIME NO c ROUNDWATER ENCOUNTERED OF CONSTRUCTION. 13. THE SEPTIC SYSTEM HAS BEEN DESIGNED TO .MAXIMUM FEASIBLE COMPLIANCE. THE FOLLOWING VARIANCES FROM TITLE FIVE AND THE TOWN OF BARNSTABLE HEALTH REGULATIONS ARE REQUIRED: 1. TITLE FIVE, SECTION 15.221 (7): LEACH AREA TO BE GREATER THAN X �- BELOW GRADE. 2. TOWN OF BARNSTABLE HEALTH REGULATION, DATED SEPTIC SYSTEM DESIGN 5-4-73: LEACH AREA TO BE LESS THAN 100' FROM WETLAND. °r, D _ FLOW ESTIMATE: BEDROOMS AT 110 GAL/DAY/BEDROOM =IM GAL/DAY 16 SEPTIC TANK: 22 24 330 GAL,/DAY x 2 DAYS = 660 GAL 3 INFILTRC'oxs 26 , , ' - - . ` ` .` ,\� , , USE�0 GALLON SEPTIC TANK (EXISTING) (MAXIMIZER CHAMBERS) 28 . co)WITH 4'OF STONELL A AROUND - (30's 1f s Z DEEP) so - _ �� l , 16 Q LEACHING AREA: ` _ USE S INFILTRATORS (MAXIMIZER CHAMBERS) \ `� '\ ' ^ • WITH '4' OF STONE ALL AROUND (30' x 11' x 2' DEEP) 34 VENT _ - - - �� - - - - - SIDE AREA: (30 + 11)2 x 2 = 164 SF (.74) = 121 GAL/DAY _ - _ / _ BOTTOM AREA: 30' x 11' = 330 SF'_ 74� __ ,C44 " f 36 i \ - - - - - - - - - - - zo CAPACITY = 365 GAL/DAY 1 - _ I _ ` -22 SEPTIC SYSTEM SECTION �,:. BENCHMARK STAKE AT . _ 2" PEASTONE r.:'-: :x•.•... �'� ELEV.- 38.7'9' �24 \ h 40 "' - - 22 cv EXIS�ING _ - _ - _ � 286 / LP� 1000 GAL S.T. - - - - = = - _ = - o COYISH WITHIN 1,2" OF f / \ iC _ - 34 44.69 FINISHED GRADE 3 4" - 1 1 2" 4z - ` ` s`i' - ' 36 FIRST FLOOR WASHED STONE 44 r H TO BE CONFIRMED � dCx I � � t 46 ► i �Q ` \ 5� F� ELEV.= 35.0 Z 48 11 V EXIT UTILITY � � ` d r '� � I e 35.75 +/- A' vh DR°p ELEV. m ® - TH-2 t . / a'tat F, �C ` ` 36.0 1000 GAL D-BOX 34.95 •F-�. E� ELEV. J� ; o32.5 �b , - _ _ _ La'v$ $� �, ` I ELEV. SEPTIC TANK 35.11 (6" OF ELEV. 41 4 O _ ,� 4e�� ` � '� (EXISTING) ELEV. STONE 30' r ` UNDER) 3 INFILTRATORS (MAXIMIZER CHAMBERS) 46- - - ' r ` ` TEE SIZES: (TO BE CONFIRMED) 34.5 WITH 4' OF STONE ALL AROUND ' EXISTING WELL GAS BAFFLE 42 - - - - - _ _ _ ' - ' (160' FROM PROPOSED 40 INLET: 6" UP, 13' DOWN AT OUTLET TEE ELEV. (30' x 11 x 2' DEEP) 40. 4 _ - - LZACH AREA) + OUTLET: 6" UP, 14" DOWN i 0. 1 40- - - - - 40 39. - 9EN C. BOUND. ATCON - ' - - FINE SITE AND SEWAGE PLAN SLIrV BOUND. 38 sue\ - - - - ' TH-1 ELEVr 41.78' 38 - - 38 KEY APPROVED BY: DATE: EXISTING CONTOUR: UTnITr LOCATION. �. lll:n PROPOSED CONTOUR: .............................. j>� � zp °O' ,�c ?F I Lt' 36. 7'_ \, '` as' ss LOT 13 DEER JUMP HILL EXISTING SPOT ELEVATION: 25.5 J� se _ _ _ _ _ i1a • "OF °'s' PROPOSED SPOT ELEVATION: 25 �Ip 3 �� " CIVIL WEST BARNSTABLE. MA. TEST HOLE:- hrjL ft V A71 0 ,.ut. UTILITY POLE: -O- ,�� ten, L `� �� NO,3885s PREPARED FOR: FENCE LINE: .. .. .. .�CL s+�u• HYDRANT: -� �.�, ' c , A & B CANCO f CANT ELLA RETAINING )PALL: DEMAREST-McLELLAN ENGINEERING � SCALE: 1"= 317 DATE: 6 5 98 TREE: r 24 scHooL STREET P.O. BOX 4e3 f WSST DENNIS, MASSACHUSETTS 02670 B REFERENCE: LAND COURT CASE #37808 DM # 61 (DsaFn) PHONE & JrAX : (508) 398-7710 ETHOMAS McLELLAN, P.:E.]l JO.HN Z. DEMAREST JR., P.L.S. ' t •