Loading...
HomeMy WebLinkAbout0355 PLUM STREET - Health WF355"Plunm Street West Barnstable A= 196-004 I Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma . 02668 1/7/2011 every page. Cityrrown State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important: When filling out A. General Information forms on the computer,use 1. Inspector: only the tab key to move your Scott Campbell cursor-do not Name of Inspector use the return key. Cardinal Company Name ' 32 Ridgetop rd. Company Address Cotuit Ma 02635 Cityrrown State Zip Code 508420-1295 S1388 Telephone Number License Number B. Certification I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate and complete as of the time of the inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of: Title 5(310 CMR 15.000):The system: ® Passes ❑ Conditionally Passes ❑ Fails; ❑ Needs Further Evaluation by the Local Approving Authority r"�3 1/7/2011 Inspect rs Signature Date The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. ****This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. ,I t5ins•09/08 Title 5 Official Inspection Form:Subsurface S e Disposal System• ge 1 of 17 1 a f Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owners Name information is required for West Barnstable Ma 02668 1/7/2011 every page. CitylTown State Zip Code Date of Inspection B. Certification con .( t ) Inspection Summary: Check A,B,C,D or E/always complete all of Section D A) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: B) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health,will pass. Check the box for"yes", "no"or"not determined" (Y, N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND(Explain below): t5ins•09108 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System•Page 2 of 17 f Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2011 every page. City/Town State Zip Code Date of Inspection B. Certification (cont.) B) System Conditionally Passes(cont.): ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND(Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below): ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND(Explain below): i ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below): C) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine'if the system is failing to protect public health, safety or the environment 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh t5ins•09108 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 17 Commonwealth of Massachusetts —60 Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2011 every page. Cityrrown State Zip Code Date of Inspection B. Certification (cont.) 2. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance: **This system passes if the well water analysis, performed at a DEP certified laboratory, for coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or .less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: D) System Failure Criteria Applicable to All Systems: You must indicate"Yes"or"No"to each of the following for all inspections: Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ❑ Liquid depth in cesspool is less than 6" below invert or available volume is less than '/day flow t5ins•09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 17 f Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M v0 Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2011 every page. Cityrrown State Zip Code Date of Inspection B. Certification (cont.) Yes No ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well. ❑ ® Arty portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis and chain of custody must be attached to this form.] ® The system is a cesspool serving a facility with a design flow of 2000gpd- 10,000gpd. ❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails.The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no"to each of the following, in addition to the questions in Section D. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ ❑ the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area—IWPA)or a mapped Zone 11 of a public water supply well If you have answered"yes"to any question in Section E the system is considered a significant threat, or answered "yes" in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. t5ins-09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 5 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2011 every page. Cityrrown State Zip Code .Date of Inspection C. Checklist Check if the following have been done. You must indicate"yes"or"no"as to each of the following: Yes No ❑ ® Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ❑ ® Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined?(If they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ❑ ® Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? Was the facility owner(and occupants if different from owner) provided with ® ❑ information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System(SAS)on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] D. System Information Residential Flow Conditions: Number of bedrooms(design): 4 Number of bedrooms(actual): 4 DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms): 440 t5ins-09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 6 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owners Name information is required for West Barnstable Ma 02668 1/7/2011 every page. City/Town State Zip Code Date of Inspection D. System Information Description: Number of current residents: 0 Does residence have a garbage grinder? ❑ Yes ® No Is laundry on a separate sewage system?[if yes separate inspection required] ❑ Yes ® No Laundry system inspected? ❑ Yes ❑ No Seasonaluse? ❑ Yes ® No Water meter readings, if available(last 2 years usage(gpd)): Detail: Sump pump? ❑ Yes ® No Last date of occupancy: 2010Date Commercial/Industrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15.203): Gallons per day(gpd) Basis of design flow(seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ❑ No Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings; if available: t5ins-09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 7 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments �Y Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2011 every page. Cityrrow i State Zip Code Date of Inspection D. System Information (cont.) Last date of occupancy/use: Date Other(describe below): General information Pumping Records: Source of information: Was system pumped as part of the inspection? ❑ Yes ❑ No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system(yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner)and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank. Attach a copy of the DEP approval. ❑ Other(describe): t5ins•09/08 Title 5 official Inspection Forth:Subsurface Sewage Disposal System•Page 8 of 17 Ii Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments y( Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2011 every page. Cityfrown State. Zip Code Date of Inspection D. System Information (cont.) Approximate age of all components, date installed (if known) and source of information: 5/17/1990 Barnstable Board Of Health ASbuilt on file Were sewage odors detected when arriving at the site? ❑ Yes ® No Building Sewer(locate on site plan): Depth below grade: feet Material of construction: ❑ cast iron ❑40 PVC ❑ other(explain): Distance from private water supply well or suction line: feet Comments(on condition of joints, venting, evidence of leakage, etc.): Septic Tank(locate on site plan): Depth below grade: 1. 5 feet Material of construction: ® concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance?(attach a copy of certificate) ❑ Yes ❑ No Dimensions: Sludge depth: t5ins•09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 9 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments "t Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2411 every page. Cityrrown State Zip Code. Date of Inspection D. System Information (cont.) Septic Tank(cont.) Distance from top of sludge to bottom of outlet tee or baffle 0 Scum thickness 0 Distance from top of scum to top of outlet tee or baffle 0 Distance from bottom of scum to bottom of outlet tee or baffle 0 How were dimensions determined? Visual Inspection Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Both tees in place at time of inspection. Tank not leaking at time of inspection. Grease Trap(locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date t5ins•09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is wired for required West Barnstable Ma 02668 1/7/2011 every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day Alarm present: ❑ Yes ❑ No Alarm level: Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments(condition of alarm and float switches, etc.): *Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No t51ns•09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owneds Name information is required for West Barnstable Ma 02668 1/7/2011 every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Distribution Box(if present must be opened) (locate on site plan): 0Depth of liquid level above outlet invert Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): box is level. one line exiting box. no evidence of solids carryover, no evidence of leaksge into or out of box. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes F11 No Alarms in working order: ❑ Yes ❑ No Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): Soil Absorption System (SAS)(locate on site plan, excavation not required): If SAS not located, explain why: 5"water in leaching at time of inspection t5ins•09108 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 17 i Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments '~ Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2011 every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Type: ❑ leaching pits number: ❑ leaching chambers number: ® leaching galleries number: 4 ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): dry soil, no signs of hydraulic failure, no damp soil or ponding, normal vegetation. Cesspools(cesspool must be pumped as part of inspection)(locate on site plan): Number and configuration Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow ❑ Yes ❑ No t5ins-09108 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 17 f Commonwealth of Massachusetts Title 5 official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2011 every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): Privy(locate on site plan): Materials of construction: Dimensions Depth of solids Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5ins•09/08 T(Ue 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 17 Commonwealth of Massachusetts 'title 5 Official Inspection Form kj_I . Subsurface Sewage disposal System form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owner's Fume information is West Barnstable required for Ma 02668 1l712011 every page. CityfTown State Zip Code Date of Inspection Dv System Information (cone,) Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ® hand-sketch in the area below ❑ drawing attached separately i € i i d i i b i S . i I i " 2 a ' t srs=�Sk t e trt ? � Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for West Barnstable Ma 02668 1/7/2011 every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Site Exam: ® Check Slope ® Surface water ® Check cellar ® Shallow wells Estimated depth to high ground water: 12+feetfeet Please indicate all methods used to determine the high ground water elevation ❑ Obtained from system design plans on record If checked, date of design plan reviewed: Date ❑ Observed site(abutting property/observation hole within 150 feet of SAS) ❑ Checked with local Board of Health-explain: Checked with local excavators, installers-(attach documentation) ❑ Accessed USGS database-explain: You must describe how you established the high ground water elevation: Excavation at time of inspection. Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5ins-09108 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 16 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments yt Kevin Nolan Property Address 355 Plum St. Owner Owner's Name information is required for west Barnstable Ma 02668 1/7/2011 every page. City/Town State Zip Code Date of Inspection E. Report Completeness Checklist ® Inspection Summary:A, B, C, D, or E checked ® Inspection Summary D (System Failure Criteria Applicable to All Systems)completed ® System Information—Estimated depth to high groundwater ® Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file t5ins•09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 17 ASSESS,OR''S MAP N0 PARCEL 00!lt LOCATION SEWAGE PERMIT NO. VILLAGE 10 . fz-�A AtiY-s 9cE INSTALLER'S NAME i ADDRESS s U 1 L D E R OR OWN ER- n _ ��GMT ��100� �'yI c��1 ��'L1y �L d cro• DATE PERMIT ISSUED DATE COMPLIANCE ISSUED �•,r�► JQ day vll `efu"� 5L 6 94 �6 WELL \k TOWN OF BARNSTABLE LOCATION �� �s SEWAGE # VILLAGE Gt, Kl ASSESSOR'S MAP & LOT INSTALLER'S NAME & PHONE NO.��' 13�J SEPTIC TANK CAPACITY �oi LEACHING FACILITYAtype)�; y (size) NO. OF BEDROOMS PRIVATE WELD PUBLIC WATER BUILDER OR OWNER 7ew ,�/6 DATE PERMIT ISSUED: DATE COMPLIANCE ISSUED: VARIANCE GRANTED: Yes�� p 57 9/ 1 s ASSESSORS MAP NO. PA RCELNO. N o..��-- _ Fes$. ............ THE COMMONWEALTH OF MASSACHUSETTS BOAR® OF HEALTH TOWN OF BARNSTABLE Applutttion for Disposal Works Tonstrurtion Permit Application.is hereby made for a Permit to Construct ( ) or Repair P4�) an Individual Sewage Disposal System at: .. -. .. ............... ------------------------------- -/,u-- -------------------------------------------------- Location-Address or Lot No. ....J ------------------------ - �6C - �s .._..._..................._ owner ddress a �C. 1�' -------------- ��... . --. .....- 'ZVU .:.?�....�G�ii. Installer Address d Type of Building Size Lot... feet U Dwelling—No. of Bedrooms______________4 _ ---------Expansion Attic ( ) Garbage Grinder ( ) Other—Type T e of Building �__..... No. of persons............................ Showers — Cafeteria a YP g -------------- P ( ) ( ) P4 Other fixtures ................................. W Design Flow............... ................gallons per person per day. Total daily flow...... ....•................••.gallons. WSeptic Tank—Liquid capacity............gallons Length................ Width................ Diameter---------------- Depth_-_.-__-__---__. x Disposal Trench—No..................... Width-------------------- Total Length.................... Total leaching area....................sq. ft. Seepage Pit No--------------------- Diameter-------------------- Depth below inlet.................... Total leaching area..................sq. ft. Z Other Distribution box ( ) Dosing tank ( ) aPercolation Test Results Performed by.......................................................................... Date........................................ Test Pit No. I................minutes per inch Depth of Test Pit.................... Depth to ground water........................ (%, Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water---------------_-______ a ----•----•••-----------•--•----••--•-----•------•-••--•.....•--•--------------------------------------------------------------••----••--...........-----..... xDescription of.Soil......to-' •--r". wwl ssadl--0---<-4 4e4l------- ...17-...... ................. U --•-•-•-••--•--••-•--•-•••--•--•--••-....---••-•----•----•---•--•-•-••-----•••-••••-----------------------•---••••---------•--------••----•---.....--••-••-••--••••••...........--------•-----•---..... Z --•---------•-------------------------------------------------------------------------------------------------------- ............................................................... U Nature of Repairs or Alterations—Answer when applicable- ---- ----eQ .. �� y•- ............................................................. Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Environmental Code—The undersigned further agrees not to place the system in operation until a Certificate of Compliiaiwyha bee is the board of health. Signed ._ ---- --- ---- e Application Approved BY cS � 91 Application Disapproved for the following reasons: ......... --------------------------------------------------------------------------------------------------------------- -------------------------------------------- ---------------------------------------- h_ 3 Daze Permit No. ----------------( Issued Date ................te?_ Fic$ ....._ -1 f' THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE Appliration for Biopoottl 10orkii Tonstrurtion trod# Application is hereby made for a Permit to Construct ( ) or Repair (3<) an Individual Sewage Disposal System at: ..-• .; l�sU/2!I �571� �"7' /ter a .; . .••• .Location-Address lJh or Lot No.•-•------------- ....... a • -- � a `> ''/ait l�`T l �lS / ...... •--------.....l../..G..�..J. owner... _ T...... ...-•--........../ ---......•... .. �J __ . . S ! Ialkr Address Pq U Type of Building Size Lot......... , Sq. feet �-t Dwelling—No. of Bedrooms................. ._..__..Expansion Attic ( ) Garbage Grinder ( ) 'A Other—Type T e of Building ,ems-� No. of persons............................ Showers C4 YP g -------------- ---------- P ( ) — Cafeteria ( ) PaOther fixtures ----------------------------------------------•_... . -•-------------------------- W Design Flow.............. ----------------gallons per person per day. Total daily flow................................... ..-..-.._.___gallons. WSeptic Tank—Liquid capacity............gallons Length.............•.. Width................ Diameter---------------- Depth................ xDisposal Trench—No..................... Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No..................... Diameter............._...... Depth below inlet.................... Total leaching area..................sq. ft. Z Other Distribution box ( ) Dosing tank ( ) aPercolation Test Results Performed bY--•---------------•---••---•--•••••------------------------------------,``Date----------- •--•------------------------ Test Pit No. 1................minutes per inch Depth of Test Pit.................... Depth t4-round water........................ f14 Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ O Description of Soil-•---- - y ._:. �a . : '� /r� G iiG) ••:5-s��U . - t' r V •-•••-••---•---••-•--••-•--...-•-•••...............•••••••-----•--•-•-•--••-----•-•-...-•----------•----•-••------••-------•----...-------••----•--------•----•-•--------_...--•••...•••-•-••-•------••. UW -•--------•-•------------------------------•-------------•-----------------------------•-•--•-•----•----•---------------------------•---•-----------•-----•-.........••--_.................. Nature of Repairs or Alterations—Answer when applicable___-9rK,!11. __.. J ----------------------------- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with I the provisions of TITLE 5 of the State Environmental Code—The undersigned further agrees not to place the system in operation until a Certificate of ComplianncceJ-has been issued by-the board off health. Signed .......1.. '% be _..�// s1'� //� ----- -- ------------------ A � j.,.Day pplication Approved BY - , .tlri JT, --------.... ... ------- i te Application Disapproved for the following reasons- ---- ------- ---- --------------------------------------------------------------------------6------------........------------ ------------------------------------ „_� Date Permit No. --- Issued .................. ...... Date THE COMMONWEALTH OF MASSACHUSETTS I BOARD OF HEALTH �4 TOWN OF BARNSTABLE r, Certifirate of C�omylianre THIS IS TO CERTIFY, That the Individual Sewage Disposal System constructed ( ) or Repaired ( ( ' Installer at -------------------------------.�,73.5�---------------- U/'0 k � l/u S>,. /—�...... has been installed in accordance-with the provisions of TITLE 5 of The State Environmental Code as described in the application for Disposal Works Construction Permit No dated ... _ -------------- THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BfCO?4S'RUED AS A GUARANTE T T THE SYSTEM WILL FUNCTION SATISFACTORY. ' DATE--J-----....- Inspector / / ... _�--'- .-..... zd% THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE J Disposal Works Tonstrudion rrutit Permission is hereby granted............ �� /! ........ ..... � - ----------------•----.......-•---............----..... to Construct ( ) or Repair an Individual.Sewage Disposal System atNo -----------------------••--•--•----•-••---•.••--- Street as shown on the application for Disposal Works Construction Permit No ?S.n� . Dated. r-h?. .......... B'oard(of�FI�lt&'�•J`"',G,.---,�...---------•---- DATE FORM 36508 HOBBS Q WARREN,INC..PUBLISHERS Flo 0r Lo,nit, n5 Y 3 2 " `cam f �a 10-13-1994 01:29PM FROM YANKEE SURVEY TO 16177700865 P:01' ASS. LOT 5 '2B3 .3 ww �6 38 SHE'D ti -peck- ASS. LOT Qn i c B. w FND. ti ASS. L021 2 RES. ZONE.- "RF" This MORTGAGE INSPECTION Plan is For FLOOD ZONE.' "C" Bank Use' orkIz TOWN: 11'E= —REGISTRY OWNER: LIND�. �IICKEY & GAIJ, FAT,.__. DEED REF: 95 /102-L ._ — _BUYER_ MARK &_EH0N_DA DONOFIUff_ _ _ DATE; 10 t 94� _ _ PLAN REF: N0__FJA.V _ _ _SCALE:1I—,= 50 -_FT. I HEREBY CERTIFY TO �� 'N1vFTbL.t�. l�UI�;�,L�',�j$__-- __THAT THE BUILDING t� 0° YANKEE SURVEY SHOWN ON THIS PLAN IS LOCATED ON THE GROUND AS o�� PAUL 'yam CONSULTANTS SHOWN AND THAT ITS POSITION DOES _ CONFORM A. h. TO THE ZONING LAW SETBACK REQUIREMENTS OF THE g �yy H 40B INDUSTRY I OAD TOWN OF ___BARNS TA. $�E__ _AND THAT No. MARSTONS MILLS, MA IOZ648 IT DOES_NOT LIE WITHIN THE SPECIAL FLOOD HAZARD g� TEU 428-0055 AREA AS SHOWN ON THE H.U.D. MAP DATED 811 T,L8 Com nit. - el 250001 001.5 C U,ato FAX: 420-555$ THIS PLAN NOT MADE FROM AX1148TRUMENT 157l32 B PA A ME EW�i` f P SURVEY NOT TO BE USED FOR FENCES, M. TOTAL P.01 > ♦ .yvrt tJ� �. ,.1 4 y. K t 6r J Y �.• r. ,+` .t4. .,,J r. :'1•., 4!) s 5J'� �' h� dL g.�',�y A � ti 1 r t �. s < tit : ;l 1 LA . O o I ( tSIj{11�11111= MIN UP j ff ,f �1I 7M � e , cewrge iawst e� PliarJEGT wi+6han/PA$rrain,p.Adl•Ylon.for r-ew�eT�I rota.eF-� - _ N � - '� • ° �LOG%iYION: xymnr,.by,.�y� L. C �angat.��dl rA�wU..ter.: _der R1n°10"o C © p��r,;.t.y 4I(sro D[9!'GFsIaM1h40A41a aesiyn w yww...•' �{ i' p svY.�n.h p' rams ;soam±eRsra ralaenklei. ' V✓eyi'DµrrisfablE,l"'(A .�...,.w '.,�aa..«� -: :p7 77 3.mfi wFk�r'r.0 fS/¢A . ^dJ y U v � No.----- - - Fee . ------------- BOARD OF HEALTH TOWN OF BARNSTABLE Rpplitation-*r Vell Con5tructionPermit Application is herebW made for a permit to 2bristruct ( ), Alter ( ), or Repair ( )an individual Well at: ---s--t °— ----------------—----------—---------------------------------—---—---- -----—— — Lo ali n — Address Assessors Map and Parcel — — Owner � Address -4 � -- r -- ------------------------ ------------------------------------- ------_----________-------------------------------- Installer — Driller Address Type of Building Dwelling-----------`—' ----------------------------------------------- Other - Type of Building ----- No. of Persons---------------------------------------------------- LJ !� Type of Well--- - —-- — -- - -- --------------- Capacity------------------------------------------ ---------------------------------------- Purpose of Well------ r,? � C Agreement: The undersigned agrees to install the aforedescribed individual well in accordance with the provisions of The Town of Barnstable Board of Health Private Well Protection Regulation — The undersigned further agrees not to place the well in operation unti a Certificate o ompli a has been issued by the Board of Health. Signed - — -- -- ------- = - 1 lq_l -- d/e Application Approved By-— l G -- -- - � f / ZR- date Application Disapproved for the following reasons:----------_-------_----___--------------------------------------:-_-_----------__------—---_------ ------- -------------------- --------- -------- ------------------------------------------------------------------------------------------- date d Permit No.-- �} ----------•------------------------------------------ Issued - da BOARD OF HEALTH TOWN OF BARNSTABLE Certificate Of Compliance THIS IS O C�R VY Mit the Individual Well Constructed (b� Altered ( ), or Repaired ( ) =" y — — Inst r bY- ------- ----- -- — — --- — - - - -- -- - at—-------i..[ f/l/� — '�— / -" =� F -----------------------------------------:-- has been installed in accordance with the pfovisions of the Town of Barnstable Board of Health�rivate Well Prot tion Regulation as described in the application for Well Construction Permit No. --`-----��Dated---- � -- THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GUARANTEE THAT THE WELL SYSTEM WILL FUNCTION SATISFACTORY. DATE — -—-- --- - - - ------ - Inspector------------------------------------------------------------------------------ No Ly ---- - --- Fee— ----------------- BOARD OF HEALTH � 11C_ 9 TOWN OF BARNSTABLE 0ppfication1bulVeYf Con5tructionPermit Application is hereby made for a permit to Construct ( ), Alter ( ), or Repair ( )an individual Well at: - s- - --P/ � -5-,_�J-, �� --__- - ----- -----_- ------ Lo ati n — Address I Assessors Map and Parcel 1 ------—Owner' -�-� ---------------------------Address I _— . __ � _�( s— ---- --- — ---- ------ ( Installer — Driller +r» Address Type of Building r Dwelling —✓:_'- --—— - -- __--------- Other - Type of Building-- __^________ No. of Persons------- --------------- Type of Well--- Capacity---------------- ----- Purpose of Well---------- ( r Agreement: The undersigned agrees to install the aforedescribed individual well in accordance with the provisions of The Town of Barnstable Board of Health Private Well Protection Regulation — The undersigned further agrees notjoq place the well in operation until a.Certificate of-Compli ,nce has been issued by the;ioard Hof•Health: 1 Signed—_�_ date Iq Application Approved By----:-- —____--- — - --- --- :--/, — -- date Application Disapproved for the following reasons:----------- ---- --- - ---- date Permit No. -J PA ---- --- ---------- Issued---------Z Ih _—_ 7 f ` date ` — — —--—— BOARD OF HEALTH TOWN OF BARNSTABLE Certificate Of Compliance � THIS IS TO CERTIFY That the Individual Well Constructed ( , Altered ( ), or Repaired ( ) - V !i,,�//i,'1------------------ -------by-- - - -------- -------------------------------------------__------------ Instal er, at--------------- -----t- -----<,.-------- Y --------- ---------------- has been installed in accordance with the provisions of the Town of Barnstable Board of Health Private Well Protection Regulation as described in the application for Well Construction Permit No. -�� Dated THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GUARANTEE THAT THE WELL SYSTEM WILL FUNCTION SATISFACTORY. DATE--------------------------- --------------------- Inspector----------------- -—------------------------------------------- BOARD OF HEALTH TOWN OF BARNSTABLE ,weir Cootruction vermit No. / -- Fee---; ------------- Permission is hereby granted------��--------- ----�---------------------------------------------------------------------------------------------- to Construct (.�),, Alter ( ), or Repa'T( )_an1ndiv1dual�Wel°l)at,: fl9 Street A as shown on the appl`ation-for a Well Construction Permit No. ! __— ----- _------ - Dated. ----—/--T -J/ -9--1-------- Board'of Health- DATE -------------— ----- 11 \Ci(iT 1!lTIT iT ttTtt! 11 ttT t TT ttTtSTilttti tt MTttttt tttiTtttitttTi lfiiitt t Tf t tTt.ttftTTTtTiTi1 ttitTti 711tTtT tt ItT it Itl tl ttT T itiT Tt} T_/11/ ,tt,:L:,:L•:f Ti11T::,:,T:iTTTi,:11t?:.:i:iTiil::?i.,,::::::::,i:a:::::::.,(;;,;,,,;,;,,,,!i?ii:,,,,::T:?::TR a:::;::.::::,..,,a11:.:,::1:,:.,,,1:,1?,,,t::?L.:1T??T?,:1??it?!41..a:1??t??,::,ti?11(Tll?i,::F:tiilT,iil?T::,,:,:,al..!i -= Mass. Cert. #:MA063 449 Route 130 Sandwich MA 02563 508 -( ) 888-6460 -- ;r = F. CLIENT: Thomas Hickey — LOCATION: Same — ADDRESS: 355 Plum Street _ td. Barnstable, iIA COLLECTED BY: Qualitv tJells SAMPLE DATE: 1-3-92 TIME: 11 :45atn _ _ DATE RECEIVED:1-3-22 SAMPLE ID: 51 h Ne JOB : n� hell WELL DEPTH. 100' RESULTS OF ANALYSIS: Parameter Units Recommended lima; Result - r _ Coliform bacteria: 100 mi ',MF Method) 0 0 pH pH units - - -- 0.0-8 5 6. 17 Conductance - ce umh�s m c �00 - - 115 _ Sodium mg. L 20.0 12.5 Nitrate-N mg%L 10.0 0.51 -- Iron - mg L --- --(l J --- 0.05 — Manganese mg L 005 _ c- Hardness mg>L as CaCO 3 500 Sulfate mg'L 250 Potassium mg!L . 20.0 - Alkalinity mg/L 200 - - _- z- Chloride - mg,`L --- --- 250--- - Turbidity NTU 5.0 -� Color APC units 15.0 Background bacteria 42 _ z=: COMMENT: 1^ z= YES No WATER iS SUITABLE FOR DRINKING PURPOSES FOR PARA METE RS,TESTED. 6� (' DATE lI1Wl11111Ullllll1111�111111J1111111111111111U11111111U111111111U1J�l�WIllUllll1111111IUUIiiillUllliliiiiiilUulitiitilllilU(IliiilliltllUUlailit 1 liilliUiillUlit1111JU111111U1111!l111111111i1t11111111111!!!lEIIA� i . 5 s s Q ' r - - + I !I{ �t-�che►'i :,. New �' `\J, � U II I / ' �+ '1