Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0105 BAYBERRY LANE
tl ( pg 8oyber'rY LN • • • • • • e. • r _t. H'the The Hanover Insurance Company 1440 Lincoln Street,Worcester,MA 01653 anover Citizens Insurance Company of America 1645 West Grand River Avenue,Howell,MI 48843 insurance Group. Massachusetts Bay Insurance Company 1440 Lincoln Street.Worcester,MA 01653 STREET PERMIT BOND License No. Bond No. BLNH380869 KNOW ALL MEN BY THESE PRESENTS,that we, DeMartin Dunham Builders LLC Of: 42 Wianno Ave#1164 Osterviile.MA.02655 , as Principal, and III The Hanover Insurance Company (A New Hampshire Corporation) ❑Massachusetts Bay Insurance Company(A New Hampshire Corporation), as Surety, are held and firmly bound unto Town OF Barnstable , as Obligee, in the penal sum of Five Thousand Dollars , good and lawful money of the United States, for the payment of which sum well and truly to be made, we bind ourselves, and our heirs, executors, administrators,jointly and severally, firmly by these presents. WHEREAS the said Principal has applied to said Obligee for a license to open, occupy. cross by vehides and obstruct a certain portion of a public sidewalk/berm, curbing. street or way in said Town Or City of Hyannis NOW, THEREFORE, THE CONDITION OF THIS OBLIGATION IS SUCH, That if Principal shall faithfully observe and honestly comply with the provisions of all Laws or Ordinances of Obligee regulating the business for which license is issued, then this obligation shall be void; otherwise to be and remain in full force and virtue. PROVIDED,THE LIABILITY OF THE SURETY upon this bond shall be and remain in full force and effect for the full period of the license,and renewals thereof, issued to the principal above named,or until ten,days after receipt by the Obligee of a written notice signed by such Surety, or its authorized agent, stating that the liability of such Surety is thereby terminated and canceled; and provided further,that nothing herein shall affect any rights or liabilities which shall have accrued under this bond prior to the date of such termination. Signed, sealed and dated the 23m day of seamier r 2020 . DeMartin Dunham Builders LLC Principal (Seal) tttttoS i iroiN ti4A ®THE HANOVER INSURANCE COMPANY ii:tit• aQiiii .F': 0 MASSACHUSETTS BAY INSURANCE COMPANY l 1972V ft ' ' v By: G� NJ zeil �/ - '. Michelle Wolf, Attorney-in-Fact 'dig/rr;r,t i i t i t dttNtt+,t I. .. Bond Number BLNH380869 THE HANOI/6R INSURANCE COMPANY MASSACHUSETTS BAY INSURANCE COMPANY CMZENS INSURANCE COMPANY OF AMERICA - FOIVEN OFA - THL9 Power of Attorney Oinks the ads of those named herein,and they have no auto bind the Company except In the manner and to the extant Wain Meted, KNOW AU.PZIWONS SY THESE PRESENTS: That THE HANOVER INSURANCE COMPANY and MASSACHUSET S BAY INSURANCE COMPANY, both being coma organized and existing under the laws of the State of New Hampshire,and CITIZENS INSURANCE COMPANY OF AMERICA,a corporation organized and exIMIng under the taws of the State of ham,(hereirar i dvidudly and callech ldy 1he"Ccnlperiy')does Hereby constitute and appoint, Michelle Wolf Of HUB Intemational New England,Norwell,MA each individually,if there be more then one named,as Its true and lawful ey(s)-In-factto elan,execute.seal,ectmawledge and deliver for,and an its behalf,and as its ad and deed any place within the United Stales,any and a9 surety bonds,recognizance% undertakings,or other suety obligations.The execution of such surety bonds,re cee,undertakings or surety obligations.In pursuance of Mies per,shall be as binding upon the Company as if they had been duly signed by the president end attested by the secretaryoftxeCompany,Intheirownproperpareons.Providedhowever,thattlispowerof20rfleWprnflalhe acts of these named herein;and they have no authority to bind the Company aroma in the manner stated and to the extent of any limitation stated below: Street Permit In the amount of: $5,000.00 That this pester is made and executed pursuant to the authonly of the following Resolutions passed by the Board of Directors of said Company,end said Relohhboft9 remain in AA bee and efftMt RESOLVED: That Ow President or any Vice President, In conjunction with any Vice President, be and they hereby are authored and empowered to eNlpob*Allemafl rest ofthe Company,H es name and use eels,to execute and echneeledge kw and on Its bell as sutwty,any and all bells,me gr suiess,centres*of hideaway,wave=of citation and ali other willow'abSontaty In the nature thereof.with Rower to attach thereto On seal oleic Company.Any such writings an eusarded by each Aaomoy -tact sloe be b>a eV upal the company a irtheY bad been duly executed and acknowledged by the regularly elected officers of the Company In thee own proper persats REEt]LVFD That any end tot Powers of Attorney end Caused Capise Bauch Amara of Attorney and cerieoafooninrespect thereto,pied and end by the preedent or vim Premed in conpondun with any Vice Preadent of the Company,halt be 6tn6na en the Company le Ihri Oarre extent sae apigear Swop gin nwryggity alli ad,even On*one or more of arB amyl _ thereon may be bandits. Ober 7,19S1—The Han rrer Insurance Comm?:Adopted April 14.1982 r McBssdseeto 1y�rurwer .ce Catripsnry:Ad1 '!: 2001—time Insurance Company of America and affirmed try oath Company on Altair 24,2014) OVAINESSSMEIRSZEMIEMANCMEMINSUBAUGE.GOMPAVIAMT'ISMAY GCs'AMYtae4Gr ads_ INSttaANCE COMPANY OF AMERICA hen caused throe presents to be sealed wen their respective capering sails,duly asd by two Mao Preadarrb.Mia 111th day W asdy.201L TIM HANOVER IN$URANOH COMPANY THE IMMt_tO=R INSURANCE EE COMPANY . .. Y I , RmoscospAter MANSACINMETIN BAYCOMPANY , ' j . ot , . s Pr , MINTf6I „. On this lee day of 'Nix., 2011 before me irons the above named Executive Vice Preaidi al MINIM to rile The Harvester Insurance . Massachusetts BaayY Insurance Company and Citizens Insurance �pprle��yy(mown to be the officers described herein, and acknowledged that the seals to the preceding Fast ument are the corporate seals of The Hannover inewanoe Company, Massediusetks Bay Insurance Company and Citizens Insurance Company of America,reapaatively,and that the said-• rate meals and that signatures as officer wereduly t urd and eakiks riP► bxtle . . . . ;k " nribliCka$10410g/ Arleen 1� lmaha Ivttterir - - V lily�n Expires hyly t;,earrwrr— tap .burs 18.2 I.the read vice Presidsnt of,, •- - . _. .�. .', i,_•.., use*Bay inSUranae told Gibers Insurance �lr Compa of merles, certify that the above and . 'no is a hitrue and correct of the aOriginal Pmerof Attorney Issued by said Gonlpanlee,and do bather certify that the said Powers of Attorney era etil in fmw, and effect. GIVEN under my hand and the sea of said Companies.at Worcester,Massachusetts,this 23rdday of September 2020 THE HANOVER INSURANCE COMPANY MASSACH 7Te BAY INSURANCE COIIRAm' 9.11,ENS OMURA CE COMPANY of AMERICA CERTIFIED DOPY I-- _...__. Corrdt(... 47-----A—... .Ieeph _oe .. lied Sze-X-Z) /A/3t70?0.21n, Mckechnie, Robert From: Mckechnie, Robert Sent: Mcnday, July 20, 2020 12:08 PM To: 'amycollins28@gmail.com' Subject: Application TB-20-1550, 105 Bayberry Lane, Barnstable Good Afternoon, Your application is denied due to the following: 1. No road bond has been submitted. CP Needs OKH approval. _, • different plans submitted, can only approve one design. ,o,__4.# Smoke detectors, CO detectors and heat detectors need to be shown on plan. ow 5. Needs conservation approval. afc 6.) Needs fire department sign off(see#4 above). This application can be reopened if al the above items are satisfied within a reasonable amount of time. And, if you are aggrieved by this notice you may file an appeal with the State Building Code Appeals Board,as specified in cite code section. within forty-five (45) days after the service of this notice. Please contact me with any questions. Thank you, Robert McKechnie Local Inspector Building Department L�er Town of Barnstable 200 Main Street Hyannis, MA 02601 508-862-4033 1 Shea, Sally From: Shea, Sally Sent: Friday, October 02, 2020 3:54 PM To: 'amycollins28@gmail.com' Cc: Mckechnie, Robert; Barrows, Debi Subject: ViewPermit, Permit No:TB-20-1550 Hi Ms. Collins, After the permit has been issued, please contact our office for documents needed to change the contractor if this is your intent. Thank you Sally Shea Town of Barnstable Assistant Zoning Admin/ Lead Permit Tech. 508-862-4031. / < (? II 1-1 DeLo -- ���eeC I GJCiaj. 0 _�DLA1�6, �. DEMADUN-01 CWOODSIDE .ACORC,' DATE(MM/DD/YYYY) `,.,� CERTIFICATE OF LIABILITY INSURANCE 9/23/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#1780862 CONTACT NAME: Michelle Wolf HUB International New England PHONE 1 FAX 600 Longwater Drive (A/C,No,Ext):(508)888-2183 (A/C,No): Norwell,MA 02061-9146 E-MAIL ADDRESS:michelle.wolf@hubinternational.com INSURER(S)AFFORDING COVERAGE NAIC# • INSURER A:Berkley Insurance Company 32603 INSURED INSURER B:Safety Indemnity Insurance Company 33618 DeMartin Dunham Builders LLC INSURER C:Associated Employers Insurance Company 11104 42 Wianno Ave#1154 INSURER D: Osterville,MA 02655 INSURER E: • INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED--BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DD/YYYY) (MMLDD/YYYY) LIMITS A X COMMERCIAL GENERAL LIABILITY 1,000,000 EACH OCCURRENCE $ CLAIMS-MADE X OCCUR CGL0124247 3/12/2020 3/12/2021 PREM SES(a occur ence) $ 100,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY JERT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: FIRST PARTY BRE $ 25,000 B AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 1,000,000 (Ea accident) $ ANY AUTO 5912890 3/3/2020 3/3/2021 BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY BODILY INJURY(Per accident) $ X AUTOS X AUTOS ONLY X NON-OWNED ONEYY (Peer accident DAMAGE $ $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTIONS $ C WORKERS COMPENSATION , PER OTH- AND EMPLOYERS'LIABILITY STATUTE X ER Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE WCC-500-5022218-2020A 5/21/2020 5/21/2021 1,000,000 N N/A E.L.EACH ACCIDENT $ ((Mandatory in NH)EXCLUDED? 1,000,000 E.L.DISEASE-EA EMPLOYEE $ If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Barnstable 7 Main st ACCORDANCE WITH THE POLICY PROVISIONS. • Hyannis,MA 02601 AUTHORIZED REPRESENTATIVE 99-2-7;# 7— . ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD 1 kc 4 F L3 E Town of Barnstable ' ' ` C . r? Old King's Highway Historic District Committee DECISION 20 AUG 27 P12 :33 Wednesday, August 26, 2020, 6:30pm The Barnstable Committee of the Old King's Highway Historic District Committee, acting in accordance with the Old King's Highway Regional Historic District Act, Chapter 470, Acts of 1973 as amended, has held a hearing and made determinations on the following applications: APPLICATIONS Mattes, Ronald & Penny, under contract with Collins, Charlotte & Charles, 105 Bayberry Lane, Barnstable, Map 335, Parcel 038,vacant land Construction of single family home; previously approved October 2018—Certificate of Appropriateness expired prior to work commencing ***certificate of Appropriateness Approved as Submitted*** ANY PERSON AGGRIEVED BY A DECISION OF THIS COMMITTEE HAS A RIGHT TO APPEAL TO THE REGIONAL COMMISSION WITHIN 10 DAYS OF THE FILING DATE OF THIS DECISION WITH THE BARNSTABLE TOWN CLERK. All certificates issued pursuant to this Act shall expire one year from the date of issue, or upon the expiration of any building permit issued as to the work authorized by said certificate, whichever date shall be later. The Committee may renew any certificate for an additional term or terms of not over one year provided application for such renewal is received prior to the expiration of said certificate. Date: August 27, 2020 117- Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards CS-040711 Expires: 01/30/2021 BERT J DEMARTIN,III 9 , 54 WESTCLIFF DRIVE �yy PLYMOUTH MA 02360 ; f- k 114, Commissioner • Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR TYPE:Individual Registration Expiration 177785 09/10/2020 BERT J. DEMARTIN BERT J.DEMARTIN 54 WESTCLIFF DR (_ PLYMOUTH,MA 02360 Undersecretary REScheck Software Version 4.6.5 Compliance Certificate Project Cunnaquid Cape Energy Code: 780 CMR 51.00: Massachusetts Residential Code, 9th Edition, Energy Efficiency Location: Barnstable, Massachusetts Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1,118 ft2 Glazing Area 14% Climate Zone: 5 (6137 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 105 Mayberry Lane Ronald&Penny Mattis James D Smith Cummaquid, MA James D Smith AIA 522 Bay Lane Centerville,MA 02632 508-367-8920 Compliance: Passes using antrade-off Compliance: O.O%Better Than Code Maximum UA: 264 Your UA: 264 The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies re �e r o -_r, ,� ... va ,krw.;iJ"` 4 �,k.&^u ;{, Gross Area 3 7� ;:q, .. M .�.,( .. .i r 5 t ��+. CaV It i Cont fi- -,- - . . D*F yy -:.fi' �t� ,nut �"a r ,T" r 3, r ,i S. y .' rU FaCYOr�' UA y � t � ,� ��" �,��� *-��Assembly r3 4':� r �`�r;�� it �i ,�'i, for r � z,� y � ,q �.� r ..ev at a bfb v , Perimeterr V e"< < alp "7 �4 fi n4x € 1� fiz �R�V U e� 04, t. 's U Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 1,118 30.0 0.0 0.033 37 Wall 1st:Wood Frame, 16" o.c. 1,480 21.0 0.0. 0.057 66 Window 1:Wood Frame:Double Pane 240 0.320 77 Door 1:Solid 38 0.320 12 Door slider:Glass 38 0.320 12 Wall 2nd:Wood Frame, 16"o.c. 570 21.0 0.0 0.057 32 • Ceiling 1:Flat Ceiling or Scissor Truss 936 49.0 0.0 0.026 24 Ceiling Kit:Cathedral Ceiling 182 49.0 0.0 0.022 4 • Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 780 CMR 51.00: Massachusetts Residential Code,9th Edition, Energy Efficiency requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. ' James D Smith AIA - 10/29/2018 Name-Title Signature � ` ' y : Date J' h Project Title: Cunnaquid Cape _- • Report date: 10/29/18 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 1 of10 28-18.rck ‘%1REScheck Software Version 4.6.5 Inspection Checklist Energy Code: 780 CMR 51.00: Massachusetts Residential Code, 9th Edition, Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and i ❑Complies Requirement will be met. 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the ❑Not Observable 0 building envelope.Thermal envelope represented on • ❑Not Applicable , construction documents. ; 103.1, :Construction drawings and ❑Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 :energy code compliance for [PR3]' :lighting and mechanical systems. ❑Not Observable 4 :Systems serving multiple ❑Not Applicable :dwelling units must demonstrate :compliance with the IECC t Commercial Provisions. E 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. 403.7 'sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR212 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable ,9) Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable 103.1 :Solar-Ready Roof:New detached ❑Complies 'Requirement will be met. [PR4]1 one-and two-family dwellings, Q ❑Does Not and multiple single-family • dwellings(townhouses)with>= ❑Not Observable 600 ft2 (55.74 m2)of roof area ❑Not Applicable oriented between 110 degrees and 270 degrees of true north comply with sections AU103.2 • through AU103.8(RB103.2 through RB103.8). , Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cunnaquid Cape Report date: 10/29/18 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 2 of10 28-18.rck 1 Section Foundation Inspection Complies? Comments/Assumptions & Req.ID 303.2.1 A protective covering is installed to DComplies Exception: Requirement is not applicable. (FO11]2 protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in.below [Not Observable grade. ❑Not Applicable 403.9 Snow-and ice-melting system controls ❑Complies Exception:Requirement is not applicable. [F012]2 installed. Oboes Not .9 ['Not Observable ❑Not Applicable Additional Comments/Assumptions: • • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cunnaquid Cape Report date: 10/29/18 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 3 of10 28-18.rck Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1.3 U-factors of fenestration products DComplies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not l J with the NFRC test procedure or DNot Observable taken from the default table. DNot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- DComplies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 DNot Observable [FR2]1 DNot Applicable 402.1.1, Glazing SHGC value(area- SHGC: SHGC: DComplies See the Envelope Assemblies 402.3.2, weighted average). ❑Does Not table for values. 402.3.3, 402.5 ['Not Observable [FR3]1 DNot Applicable �gj 402.1.1, ;Door U-factor. U- U- DComplies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FRl]1 ❑Not Observable 0 ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier '❑Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. ['Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built DComplies Requirement will be met. 1 [FR20]1 is listed and labeled as meeting • DDoes Not C) AAMA/WDMA/CSA 101/1.5.2/A440 ['Not Observable or has infiltration rates per NFRC 400 that do not exceed code DNot Applicable limits. . 402.4.5 IC rated recessed lighting fixtures , DComplies Exception:Requirement is ( [FR16]2 sealed at housing/interior finish ❑Does Not not applicable. and labeled to indicate<_2.0 cfm leakage at 75 Pa. DNot Observable DNot Applicable 403.3.1 Supply and return ducts in attics DComplies Exception:Ducts located [FR12]1 insulated>=R-8 where duct is ❑Does Not completely inside the ✓ >=3 inches in diameter and >= t DNot Observable building envelope. R-6 where<3 inches.Supply and return ducts in other portions of " DNot Applicable the building insulated >=R-6 for diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.5 Building cavities are not used as , DComplies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable DNot Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies Exception: Requirement is [FR17]2 above 105°F or chilled fluids ODoes Not not applicable. U below 55°F are insulated to all- ❑Not Observable DNot Applicable 403.4.1 Protection of insulation on HVAC ['Complies Exception:Requirement is [FR24]1 piping. ❑Does Not not applicable. O DNot Observable ONot Applicable I1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cunnaquid Cape Report date: 10/29/18 1 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 4 of10 28-18.rck Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions &Req.ID 403.5.3 Hot water pipes are insulated to R- R- ❑Complies Requirement will be met. (FR18)2 >_R-3. ❑Does Not ['Not Observable ❑Not Applicable 403.6 Each dwelling unit of a residential ❑Complies Requirement will be met. [FR19]2 building provided with ❑Does Not 'continuously operating exhaust, supply or balanced mechanical [Not Observable ventilation that has been site ❑Not Applicable verified to meet a minimum I airflow per Section N1103.6. Additional Comments/Assumptions: • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cunnaquid Cape Report date: 10/29/18 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 5 of10 28-18.rck • Section Plans Verified Field Verified Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 ,All installed insulation is labeled a ❑Complies Requirement will be met. [IN13]2 or the installed R-values ['Does Not provided. ['Not Observable • ❑Not Applicable 303.2 Wall insulation is installed per DComplies Requirement will be met. [IN4]1- manufacturer's instructions. '❑Does Not ❑Not Observable • DNot Applicable 303.2, Floor insulation installed per ❑Complies Requirement will be met. 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the ❑Not Observable underside of the subfloor,or floor framing cavity insulation is in • ❑Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least V2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable • 402.1.1, Floor insulation R-value. R- R- i❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 0 Steel ❑ Steel ['Not Observable ❑Not Applicable Additional Comments/Assumptions: • • • • . 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cunnaquid Cape Report date: 10/29/18 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 6 of10 28-18.rck r'.. • Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 303.1.1.1, Ceiling insulation installed per ° DComplies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every • [Not Observable 300 ft2. ONot Applicable 303.3 Manufacturer manuals for , .❑Complies Requirement will be met. [F118]3 mechanical and water heating . ElDoes Not systems have been provided. [Not Observable t❑Not Applicable 401.3 Compliance certificate posted. ❑Complies Requirement will be met. [F17)2 ❑Does Not ❑Not Observable ONot Applicable 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. I 402.2.2, ❑ Steel ❑ Steel ONot Observable 402.2.E[FI1]1 ❑Not Applicable 402.2.3 =Vented attics with air permeable +❑Complies Requirement will be met. [F122]2 1 insulation include baffle adjacent ❑Does Not ;to soffit and eave vents that extends over insulation. ONot Observable ONot Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met. [FI3]1 insulation>_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ONot Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50 = ['Complies Requirement will be met. [FI17]1 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. • ['Not Observable ONot Applicable 403.1.1 1 Programmable thermostats ❑Complies Requirement will be met. [FI9]2 f installed for control of primary '❑Does Not {heating and cooling systems and i initially set by manufacturer to ONot Observable code specifications. ❑Not Applicable 403.1.2Heat pump thermostat installed ❑Complies Exception:Requirement is [FI10]2 on heat pumps. ❑Does Not not applicable. ['Not Observable ,❑Not Applicable 403.2 t Hot water boilers supplying heat '❑Complies Exception:Requirement is [F126]2 through one-or two-pipe heating '❑Does Not not applicable. systems have outdoor setback ONot Observable control to lower boiler water temperature based on outdoor ONot Applicable temperature. 403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met. [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. ° , ['Not Observable I❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cunnaquid Cape Report date: 10/29/18 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 7 of10 28-18.rck , , Section Plans Verified Field Verified '' I # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Requirement will be met. [FI27]1 determine air leakage with ft2 ft2 ElDoes Not either:Rough-in test:Total leakage measured with a ['Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure.Post- construction or rough-in testing and verification done by a HERS Rater, HERS Rating Field Inspector,or an applicable BPI Certified Professional. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 OComplies Requirement will be met. [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ['Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa.For rough-in ONot Observable tests,verification may need to ONot Applicable occur during Framing Inspection. 403.5.1 Circulating service hot water ❑Complies Exception:Requirement is [FI11]2 systems have automatic or ElDoes Not not applicable. accessible manual controls. ❑Not Observable ¢ - ONot Applicable 403.5.1.1 Heated water circulation systems )❑Complies Requirement will be met. [F128]2 have a circulation pump.The 'ElDoes Not system return pipe is a dedicated return pipe or a cold water supply ['Not Observable pipe.Gravity and thermos- 1 ONot Applicable - syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the . occupancy.Controls automatically turn off the pump , when water is in circulation loop a is at set-point temperature and I no demand for hot water exists. 403.5.1.2 Electric heat trace systems ,❑Complies Exception:Requirement is [FI29]2 comply with IEEE 515.1 or UL ,❑Does Not not applicable. 515.Controls automatically pilot Observable adjust the energy input to the .heat tracing to maintain the ❑Not Applicable • desired water temperature in the piping. 1 403.5.2 Water distribution systems that ❑Complies Exception: Requirement is [FI30]2 have recirculation pumps that DDoes Not not applicable. pump water from a heated water supply pipe back to the heated ONot Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold • $water piping to 1049F. i 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) I Project Title: Cunnaquid Cape Report date: 10/29/18 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 8 of10 28-18.rck Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.5.4 Drain water heat recovery units ❑Complies Exception:Requirement is [F131)2 tested in accordance with CSA ❑Does Not not applicable. B55.1.Potable water-side pressure loss of drain water heat ['Not Observable recovery units<3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for I individual units connected to three or more showers. 403.6.1 All mechanical ventilation system ❑Complies Requirement will be met. [FI25]2 fans not part of tested and listed • ❑Does Not HVAC equipment meet efficacy ,and air flow limits. ['Not Observable ❑Not Applicable 403.6.2 Installed performance of the J❑Complies Requirement will be met. [FI32)3 mechanical ventilation system ODoes Not tested and verified by a HERS Rater, HERS Rating Field ❑Not Observable Inspector,or an applicable BPI ❑Not Applicable Certified Professional,and measured using a flow hood,flow grid,or other airflow measuring device in accordance with either RESNET Standard Chapter 8 or ACCA Standard 5. 403.6.3 Ventilation devices and ❑Complies Requirement will be met. [FI33j3 equipment are tested and ❑Does Not certified by Air Movement and Control Association("AMCA")or 'ONot Observable Home Ventilating Institute ONot Applicable ("HVI")and the certification label is affixed to product.Where multiple duct sizes and/or exterior hoods are standard options,the minimum size shall not be used. 403.6.4 'Sound ratings for fans used for ❑Complies Requirement will be met. [F134]3 whole building ventilation are ❑Does Not rated at a maximum of one sone. ONot Observable ❑Not Applicable 403.6.5 Owner and the occupant of the ❑Complies Requirement will be met. [F135]3 dwelling unit provided with DDoes Not information on the ventilation design and systems installed, ❑Not Observable including instructions on the ONot Applicable proper operation and maintenance of the ventilation ; systems.Ventilation controls shall be labeled with regard to their function. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cunnaquid Cape Report date: 10/29/18 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 9 of10 28-18.rck Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.6 All ventilation air inlets are '❑Complies Requirement will be met. [FI36]3 unobstructed and located a ❑Does Not minimum of 10 feet from other vent openings that constitute ❑Not Observable known contamination sources. ❑Not Applicable Outdoor forced air inlets are covered with rodent screens..A whole house mechanical ventilation system does not extract air from an unconditioned basement unless approved by a registered design professional. Where wall inlet or exhaust vents are<7 feet above finished grade in the area of the venting an identification plate is permanently mounted to the exterior of the building at a>=8 feet above grade directly in line with the vent terminal. 404.1 75%of lamps in permanent ❑Complies Requirement will be met. [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage [Not Observable lighting. 5111Not Applicable 404.1.1 Fuel gas lighting systems have A❑Complies Requirement will be met. [FI23]3 no continuous pilot light. ❑ Does Not 1 ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cunnaquid Cape Report date: 10/29/18 Data filename: C:\Users\Owner\Documents\PCB work 2018\Bert Mattes job 8-13-18\Bert Matis Cape 1- Page 10 of10 28-18.rck 1 780 C R R 5I .00: Massachusetts Residential Code, 9th Edition, Energy Efficiency Energy Efficiency certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 0.00 Floor 30.00 - Ceiling / Roof 49.00 Ductwork (unconditioned spaces): ' IMMO Door Rating U-Factor Window 0.32 Door 0.32 Heating 3 Cooling Equipment Ntitiggl Heating System: Cooling System: Water Heater: Name: Date: Comments Mattis Cummaquid,MA BeamChek v2016licensed to:Phillip Birchall Reg#2101-2918 • Bearing wall Toilet to Kitchen Date:10/29/18 Selection W 6x 20 50 ksi Wide Flange Steel Lateral Support: Lc=5.4 ft maX.—I Conditions Actual Size is 6 x 6-1/4 in. Min Bearing Length R1=0.8 in. R2=0.8 in. (1.0)DL Deft= 0.15 in Recom Camber=0.23 in Data Beam Span 14.0 ft Reaction 1 LL 2730# Reaction 2 LL 2730# Beam Wt per ft 20.0# Reaction 1 TL 4235# Reaction 2 TL 4235# Bm Wt Included 280# Maximum V 4235# Max Moment 14823'# Max V(Reduced) N/A TL Max Dell L/240 TLActual Defl L/386 LL Max Deft L/360 LL Actual Deft L/599 Attributes Section(in3) Shear(in2) TL Deft(in) LL Deft Actual 13.40 1.61 0.43 0.28 Critical 5.39 0.21 0.70 0.47 Status OK OK OK OK Ratio 40% 13% 62% 60% Fb(psi) Fv(psi) E(psi x mil) Values Ref.Value Fy 50000 50000 29.0 Adjusted Values 33000 20000 29.0 Adjustments Yp Factor,Lc '0.66 0.40 • Loads • Uniform LL:390 Uniform TL: 585 =A Uniform Load A • R1=4235 R2=4235 • SPAN=14 FT Uniform and partial uniform loads are lbs per lineal ft. • Mattis Cummaquid,MA BeamChek v2016 licensed to:Phillip Birchall Reg#2101-2918 Frt->back @ Kit Date:10/29/18 Selection IN 8x 28 50 ksi Wide Range Steel Lateral Support Lc=5.9 ft max. Conditions Actual Size is 6-1/2 x 8 in. Min Bearing Length R1=0.9 in. R2=0.9 in. (1.0)DL Defl= 0.25 in Recom Camber=0.38 in Data Beam Span 17.0 ft Reaction 1 LL 2555# Reaction 2 LL 2686# Beam Wt per ft 28.0# Reaction 1 TL 5074# Reaction 2 TL 5265# Bm Wt Included 476# Maximum V 5265# Max Moment 31468'# Max V(Reduced) N/A TL Max Deft L/240 TL Actual Deft L/378 LL Max Deft L/360 LL Actual Defl L/705 Attributes Section(in3) , Shear(ir2) TL Deft(in) LL Deli Actual 24.30 2.30 0.54 029 Critical 11.44 026 0.85 0.57 Status OK OK OK OK Ratio 47% 11% 64% 51% Fb(psi) Fv(psi) E(psi x mil) Values Ref.Value Fy 50000 50000 29.0 Adjusted Values 33000 20000 29.0 Adjustments YP Factor,Lc • 0.66 0.40 At Point Loads:Provide these minimum bearing lengths in inches or provide web stiffeners. B=0.9 C=0.9 Loads Uniform LL:60 Uniform TL: 90 =A Point LL Point TL Distance Par Unif TL Start End 1491 B=2363 6.5 H=102 0 17.0 2730 C=4236 10.0 H Uniform Load A Pt loads: i R1=5074 R2=5265 SPAN=17 FT Uniform and partial uniform loads are lbs per lineal ft. • Mattis • Cummaquid,MA BeamChek v2016 licensed to:Phillip Birchall Reg#2101-2918 • Kitchen Ridge Date: 10/29/18 Selection (4)2x 12 SPF#2 Lu=0.0 Ft Conditions NDS 2012 Mn Bearing Area R1=5.5 in2 R2=5.5 in2 (1.5)DL Defl= 0.17 in Data Beam Span 14.2 ft Reaction 1 LL 1491# Reaction 2 LL 1491 # Beam Wt per ft 16.4# Reaction 1 TL 2353# Reaction 2 TL 2353# Bm Wt Included 233# Maximum V 2353# Max Moment 8353'# Max V(Reduced) 2042# TL Max Defl L/240 TLActual Defl L/474 LL Max Defl L/360 LL Actual Defl L/885 Attributes Section(in3) Shear(n2) TL Defl(in) LL Defl Actual 126.56 67.50 0.36 0.19 Critical 114.56 22.69 0.71 0.47 Status OK OK OK OK Ratio 91% 34% 51% 41% Fb(psi) Fv(psi) E(psi x mu) Fcl(psi) Values Reference Values 875 135 1.4 425 Adjusted Values 875 135 1.4 425 Adjustments CF Size Factor 1.000 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A • Cm Wet Use 1.00 1:00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:210 Uniform TL• 315 =A Uniform Load A R1 =2353 R2=2353 SPAN=14.2 FT Uniform and partial uniform loads am lbs per lineal ft, October 5,2020 Dear Sir or Madam: I hereby authorize Bert Dimartin to represent me in all matters pertaining to the building permit at 105 Bayberry Lane,Cummaquid,Barnstable. Mi ael A.Collins 1