Town of Barnstable
�p114E T , Regulatory Services
a„ Thomas F.Geiler,Director
BARNSTABLE, * Building Division
�qj i639• ��� Thomas Perry,Building Commissioner
200 Main,Street, Hyannis,MA 02601
Office: 508-862-4038 Fax: 508-790-6230
May 20, 2009
Ms. Kristy Senatori
Cape_ Cod Commission
3225 Main Street j
P.O. Box 226
Barnstable, MA 02630
Dear Kristy, -
This letter is in regards to the existing building which F.W. Webb is in the
process of transferring their operation to in the Industrial Park. Recently this was
before the Cape Cod Commission because this company wished to expand the
present building and triggered the DRl thresholds. This DRI has recently been
approved. Now the applicant wishes to repair the existing roof of the building
that is presently in existence. This is a normal repair and would normally never
involve the Cape Cod Commission in such a circumstance and therefore, we see
no reason not to issue a building permit in this instance. This is an emergency
repair/upgrade only and is necessary to maintain the existing building. I viewed
the roof on May 20, 2009 and agree that this is necessary for safety.
If you should require additional information, please feel free to contact me.
Sincerel ,
Thomas Perry, CBO
Building Commissioner
P, 1
Communication Result Report ( May, 21. 2009 9: 20AM )
2)
Date/Time : May. 21. 2009 9: 19AM
File Page
No, Mode Destination Pg (s) Result Not Sent
---------------------------------------=------------------------------------------------------------
3432 Memory TX 915083023136 P. 2 OK
----------------------------------------------------------------------------------------------------
Reason for error
E. 1) Hang up or line fail E. 2) Busy
E. 3) No answer E. 4) No facsimile connection
E. 5) Exceeded max. E—ma i 1 size
Y�TMe. Town of Barnstable
Regulatory Services
ee,
• Thomas F.Geiler,Dim-tor -
eoµP•`• Bul ding Division
Tam Perry,BeflEing Commfnionor '
200 Mein Street,T4yan it,MA 02601
www.to—b—uLlbiLr I
Office: 508-862-4639 Fax 508279076230
PLEAST;FORWARD TZ;TE ATTACHED PAGE(S)TO:
TO: j4t_,.T'j
ATTN:
FAX NO: (�oD) 3Loa 13 4
FROM: T
DATE: s Jal�a�
r'AGC(S): Z- (rNCLUDING COVER Slxr ETI
I
P. 1
Communication Result Report. ( May, 21. 2009 9: 18AM )
2)
Date/Time : May, 21, 2009 9: 18AM
File Page
No, Mode Destination P s g ( ) Result Not Sent
---------------------------=------------------------------------------------------------------------
3431 Memory TX 919784610480 P. 2 OK
----------------------------------------------------------------------------------------------------
Reason for error
E. 1) Hang uP or line fail E. 2) Busy
E. 3) No answer E. 4) No facsimile connection
E. 5) Exceeded max. E—mail size
Town of Barnstable
Regulatory Services
•suw�ae• Thomas F.Geiler,Director
M 8
^,Eon•` Building Division -.
Toni Perry,Building commialoner
zoo Main svnnt,Iipunis,MA 02601
- rvww:fovn.barnstayle.ma.n.+ '
Office:508-862-4038 Fax:508.791-6230
PLFASE FORWARD ME,ATTACHLD PAGE(S)TO:
TO:
ATTN: �
rAKNo: ay—i$_ L4LPi
DATE:
(INCLUDING covFR snzn),
Development of Regional Impact(DRI)
Referral Form
Please attach a copy of the original development permit application or site plan review, subdivision, or other
application showing the date on which it was received by the Municipal Agency. Receipt of this information
via the U.S. Mail or delivered in person to the Cape Cod Commission constitutes a referral for purposes of
Chapter 716 of the Acts of 1989, as amended.
Referred by:
Town and Agency: Barnstable, from the Building Commissioner through the Town Manager
Official: Building Commissioner through the Town Manager
X Mandatory referral
Discretionary Referral
Limited Discretionary referral (please see back of this form)
Project Name FW Webb
Project Proponent Name
Address .1-60 Middlesex Turnpike Bedford, MA 01730
Tel: 781-272-6600 Fax:
Brief description of the project including, where applicable, gross floor area, lots, units; acres, and
specific uses:
Add 22,500 sq. ft. footprint 2 story warehouse/office building to existing 22, 500 sq ft. footprint 2
story office/warehouse: former mill store warehouse building.
Project location:
Map 314 parcel 024 002(108 Breeds Hifl Road-Barnstable
List of municipal agency(ies) before which a municipal development permit is pending:
John C�Vl'n
amm, Tom Perry -
Townager Building Commissioner
Forward to: Date:
Cape Cod Commission
3225 Main Street
Barnstable, MA 0263..0 -
Design-Science Intemational,Inc.
200 Baker Avenue-Suite 102
Concord,Massachusetts 01742
Tel:(978)369-6565
Fax(978)287-0076
E Mail:Andy@DesignSciencetnacom
Andrew R.Loverud,LEED AP
President
December 9, 2009
Mr. Paul Roma
Building Inspector
TOWN OF BARNSTABLE
Building Department
200 Main Street
Hyannis, MA 02601
Proj: F W Webb, 108 Breeds Hill Road, Hyannis, MA
Subj: Code Review Items
Dear Mr. Roma,
Jesse Wilbur, the site superintendant for J M Coull (construction manager for this
project) asked me to submit a letter to your office regarding a few code
interpretations, for your project file. This request was based on a walk-through
with Deputy Fire Chief Francis Pulsifer December 8, 2009.
Item 1:
Deputy Chief Pulsifer asked about the glass in the door at stairway 1 which
separates the stairway from the"Self Serve" on the first floor and the hallway
outside the"showroom" on the second floor.
We had consulted with our code consultants, Sullivan Code Group, about this
during our construction drawing process. Based on the use group and since this
is a two story building, and is a fully sprinklered building, only one of the two
required stairs needs to be a rated stairway. Stair#2 is the rated stairway. In
fact, we do not even need to have a door on this stairway on either floor. This,
can be an open stairway(MA State Building Code 1019.1, exceptions 8 and
We have chosen to install a door on each floor, anyway (which will be on ap`1,
closer), for security reasons. '
1
y
tM '
Item #2:
Deputy Chief Pulsifer asked about the new interior windows (two, that are 48"x
48° each)we installed in the wall between the lunch room and the warehouse.
We had reviewed the code and determined that we are allowed up to 25% linear
length of the wall for openings, and the maximum area of the of each opening
can not be more than 120 square feet. The wall is 112 feet long and all of the
windows (new and existing) add up to 18 linear feet. 18/112 = 16%, which is
less than the 25% allowed. Further, our new openings are 16 square feet each,
which is less than the 120 square feet each allowed. Further, since this is a fully
sprinklered building, we are not limited to the size of the'openings.
(Massachusetts State Building Code 706.7, and Exception 1).
In summary, we feel that the design meets the current codes. Please feel free to
contact me with any thoughts or questions. Thanks for your help.
Sincerely,
Andy Loverud
Project Architect
any �G e
�C Na'jam 6
0 ax=4
p4
2