HomeMy WebLinkAbout0090 HARBOR POINT ROAD go H ,boa° ()aro- eci vii,
TO f i G< Poi Jr Lb
IP
TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION
Map 352 Parcel 001 Permit# d 3
Health Division Date Issued 1
Conservation Division- Application Fee S
' Tax Collector � ''`�' Permit Fee
Treasurer po°
Planning Dept.
Date Definitive Plan Approved by Planning Board
Historic-OKH Preservation/Hyannis
Project Street Address 90 Harbor Point Road Village -- a.--vN..S.\- 1�1/>
Owner Philip 3. & Mary Ellen Nelson Address 2640 Webster ,S ., San FTTh.nci5Rco, CA 94123
y j c=
Telephone 415-922-0525 " .;a:P CD
,:7 �.,
r�
Permit Request Finish the interior of an existing detached garage; to inlude 2vbedtgpms and
1 bathroom ,ap
o
y C:) 3—
Square feet: 1st floor: existing 137 proposed - 2nd floor: existing 688 proposed - Total new
Zoning District RF-1 Flood Plain - Groundwater Overlay -
Project Valuation I'-75Wo00 Construction Type Wood Frame
Lot Size 15 acres Grandfathered: ❑Yes (la No If yes, attach supporting documentation.
Dwelling Type: Single Family Ul Two Family ❑ Multi-Family(#units)
All work is interior
Age of Existing Structure 3 years Historic House: ❑Yes JD No On Old King's Highway: P Yes ❑No
:Basement Type: ❑Full ❑Crawl ❑Walkout )0 Other Existing slab on grade
Basement Finished Area(sq.ft.) - Basement Unfinished Area(sq.ft) -
Number of Baths: Full: existing - new 1 Half:existing - new -
Number of Bedrooms: existing - new 2
Total Room Count(not including baths): existing - new 3 First Floor Room Count -
Heat Type and Fuel: =Gas ❑Oil ❑ Electric ❑Other
Central Air: 3 Yes ❑ No Fireplaces: Existing - New - Existing wood/coal stove: ❑Yes ®No
Detached garage:❑existing ❑new size 30x23 Pool:❑existing ❑new size Barn:❑existing ❑new size
Attached garage:❑existing ❑new size Shed:❑existing ❑new size Other:
Zoning Board of Appeals Authorization ❑ Appeal# Recorded❑
Commercial ❑Yes ❑No If yes, site plan review# _
Current Use Single family Proposed Use Single Family
BUILDER INFORMATION TO4/Name McPhee Associates, Inc Telephone Number 5083851 2 ''''''"---
Address 1 1 R7 Rn,,;-P 1 34/Po Ilex 797 License# CS 97057
East Dennis, MA 02641 Home Improvement Contractor# 104158
Worker's Compensation# WCC5002061012011
ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO Fl;,prmrpa transfer facility
der
SIGNATURE •+% ^\��L /10414, DATE 644
FOR OFFICIAL USE ONLY
PERMIT NO.
DATE ISSUED
}
MAP/PARCEL NO.
ADDRESS VILLAGE
OWNER
DATE OF INSPECTION:
FOUNDATION
FRAME
INSULATION
FIREPLACE
ELECTRICAL: ROUGH FINAL
PLUMBING: ROUGH FINAL
GAS: ROUGH FINAL
FINAL BUILDING ti
DATE CLOSED OUT
ASSOCIATION PLAN NO.
Philip B. Nelson and Mary Ellen Nelson, Trustees
The 1999 Philip B. Nelson and Mary Ellen Nelson
Revocable Trust
2640 Webster Street
San Francisco, CA 94123
June 15, 2011
TO: TOWN OF BARNSTABLE
To Whom It May Concern:
This letter is to confirm that I, Philip B. Nelson and Mary Ellen Nelson, owner of the
property at 90 Harbor Point Road, Cummaquid, MA authorize McPhee Associates, Inc,
to act on our behalf as the contractor for work to be performed at the above referenced
address.
Philip B. Nelson
Mary Ellen Nelson
REScheck Software Version 4.4.1
, Compliance Certificate
Project Title: The Nelson Residence
Energy Code: 2006 IECC
Location: Barnstable, Massachusetts
Construction Type: Single Family
Building Orientation: Bldg.faces 90 deg.from North
Conditioned Floor Area: 688 ft2
Glazing Area Percentage: 10%
Heating Degree Days: 6137
Climate Zone: 5
Construction Site: Owner/Agent: Designer/Contractor:
90 Harbor Point Road Rob McPhee McPhee Associates, Inc.
Cummaquid,MA 02637 McPhee Associates,Inc. 1382 Route 134
1382 Route 134 P.O.Box 797
P.O.Box 797 East Dennis,MA 02641
East Dennis,MA 02641 508-385-2704
508-385-2704
robm@mcpheeassociatesinc.com
r - v
Oo�i ► iass�es o y l� 3aclaff�i�, //�o� f ! .. i ,,.. .. if
Compliance:0.7%Better Than Code Maximum UA:131 Your UA:131
The%Better or Worse Than code index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Gross Cavity , cont._ Glazing QUA
Assembly Area or R=Value °, R-Value or Door - y
ty Perimeter U-Factor.
Ceiling 1:Flat Ceiling or Scissor Truss 633 38.0 0.0 19
Ceiling 2:Cathedral Ceiling(no attic) 117 30.0 0.0 4
Wall 1:Wood Frame, 16"o.c. 242 21.0 0.0 13
Orientation:Left Side
Window 1:Wood Frame:Double Pane with Low-E 15 0.380 6
SHGC:0.33
Orientation:Left Side
Wall 2:Wood Frame, 16"o.c. 250 21.0 0.0 13
Orientation:Back
Window 2:Wood Frame:Double Pane with Low-E 30 0.380 11
SHGC:0.33
Orientation:Back
Wall 3:Wood Frame, 16"o.c. 242 21.0 0.0 12
Orientation:Right Side
Window 3:Wood Frame:Double Pane with Low-E 28 0.380 11
SHGC:0.33
Orientation:Right Side
Wall 4:Wood Frame, 16"o.c. 220 21.0 0.0 11
Orientation:Front
Window 4:Wood Frame:Double Pane with Low-E 20 0.380 8
SHGC:0.33
Orientation:Front
Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 688 30.0 0.0 23
lennox#G51 MP-24B-045:Forced Hot Air 92.1 AFUE
LENNOX#XC13-024:Electric Central Air 13 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2006 IECC requirements in
REScheck Version 4.4.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: The Nelson Residence Report date: 06/23/11
Data filename:P:\Construction Clients\Nelson Detached Garage\Permitting\Nelson REScheck for garage 6-23-11.rck Page 1 of 5
6-criNn - c/z---7//1
Name-Title Signature Date
Project Title: The Nelson Residence ,_. �. ... _._ Report date:06/23/11
Data filename: P:\Construction Clients\Nelson Detached Garage\Permitting\Nelson REScheck for garage 6-23-11.rck Page 2 of 5
REScheck Software Version 4.4.1
Inspection Checklist
p
Ceilings:
❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
❑ Ceiling 2:Cathedral Ceiling(no attic),R-30.0 cavity insulation
Comments:
Above-Grade Walls:
• WallFr
ame,1:Wood F ame, 16"o.c.,R-21.0 cavity insulation
Comments:
❑ Wall 2:Wood Frame, 16"o.c.,R-21.0 cavity insulation
Comments:
❑ Wall 3:Wood Frame, 16"o.c.,R-21.0 cavity insulation
Comments:
❑ Wall 4:Wood Frame, 16"o.c.,R-21.0 cavity insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 2:Wood Frame:Double Pane with Low-E,U-factor:0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 3:Wood Frame:Double Pane with Low-E,U-factor:0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
❑ Window 4:Wood Frame:Double Pane with Low-E,U-factor:0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Note:Up to 15 sq.ft.of glazed fenestration per dwelling is exempt from U-factor and SHGC requirements.
Floors:
❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation
Comments:
Floor insulation is installed in permanent contact with the underside of the subfloor decking.
Heating and Cooling Equipment:
❑ lennox#G51 MP-24B-045:Forced Hot Air:92.1 AFUE or higher
Make and Model Number:
❑ LENNOX#XC13-024:Electric Central Air: 13 SEER or higher
Project Title: The Nelson Residence Report date: 06/23/11
Data filename:P:\Construction Clients\Nelson Detached Garage\Permitting\Nelson REScheck for garage 6-23-11.rck Page 3 of 5
Make and Model Number:
• ,' Air'Leakage:
• Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
• Recessed lights are either 1)Type IC rated with enclosures sealed/gasketed against leaks to the ceiling,or 2)Type IC rated and ASTM
E283 labeled,or 3)installed inside an air-tight assembly with a 0.5"clearance from combustible materials and a 3"clearance from
insulation.
Sunrooms:
• Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U-factor of 0.50 and the maximum
skylight U-factor of 0.75.New windows and doors separating the sunroom from conditioned space meet the building thermal envelope
requirements.
Vapor Retarder:
• Vapor retarder is installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors;or it has been determined that
moisture or its freezing will not damage the materials;or other approved means to avoid condensation are provided.
Comments:
Materials Identification and Installation:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
Li Insulation is installed in substantial contact with the surface being insulated and in a manner that achieves the rated R-value.
Li Materials and equipment are identified so that compliance can be determined.
▪ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
Duct Insulation:
❑ Ducts in unconditioned spaces or outside the building are insulated to at least R-8.
❑ Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to at least R-6.
Duct Construction:
• Air handlers,filter boxes,and duct connections to flanges of air distribution system equipment or sheet metal fittings are sealed and
mechanically fastened.
❑ All joints,seams,and connections are made substantially airtight with tapes,gasketing,mastics(adhesives)or other approved closure
systems.Tapes and mastics are rated UL 181A or UL 181B.
Li Building framing cavities are not used as supply ducts.
• Automatic or gravity dampers are installed on all outdoor air intakes and exhausts.
• Additional requirements for tape sealing and metal duct crimping are included by an inspection for compliance with the International
Mechanical Code.
. Temperature Controls:
• Thermostats exist for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Heating and Cooling Equipment Sizing:
❑ Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code.
Circulating Service Hot Water Systems:
❑ Circulating service hot water pipes are insulated to R-2.
❑ Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the
system is not in use.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-2.
Certificate:
• A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values;window
U-factors;type and efficiency of space-conditioning and water heating equipment.
NOTES TO FIELD:(Building Department Use Only)
Project Title: The Nelson Residence Report date: 06/23/11
Data filename:P:\Construction Clients\Nelson Detached Garage\Permitting\Nelson REScheck for garage 6-23-11.rck Page 4 of 5