HomeMy WebLinkAbout0210 KEVENEY LANE a\ o .c-,1,6A(k)L0
„
•
• .•
, ' ' , ,
-
, '
.
• ,
, .
, .
,
. .
,
,
. ,
o
•
.r _•\—,, TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION /.J `t
Map 5 / Parcel 00-//G0 / . Permit# g"--0 Y7
Health Division CsCT `o/6 , 9 3'163 Date Issued _l G'
/d 553 s.,�'f c� Application0
Conservation Division/T5't �� - �' 0�.��9/�' /��£� Fee �
Tax Collector Ne - oC��� � � � y�(� v�(�-- Permit Fee 7 �
Treasurer 1 t / 1 01 ID ott
EXISTING SEPTIC SYSTEM
Planning Dept.
Date Definitive Plan Approved by anning Board • LIMITED TO #OF BEDROOMS
Historic-OKH Preservation/Hyannis
,,)
Project Street Address 210 Keveney Lane I•
_�
, l
�c --
Village � �. -- � -v�S�C.�b1L �:_
Owner Paul & Anne Fitzgerald i' Address 210 Keveney Lane, Cumms�cuid, d0?537
Telephone (508)302-2419 -� :r
Permit Request Renovations to an existing home for inc:_ude enlarg ng an er��'ist .n ;(53117.1 .,(0 ch € r
raisin: a portion of the second floor roof, •ch<nc ng interior partitions, pe_;7 :7.Lding; 4a7nd
roof shingles where disturbed, .]4. r,, ei ,,c1x- ' bin - •+T
Square feet: 1st floor: existing 1,113 proposed 51 2nd floor: existing 909 proposed - Total new 2,073
Zoning District RF-1 Flood Plain ?one C Groundwater Overlay
Project Valuation ?40,396•CC Construction Type Wood Framed
Lot Size 100,183 s q. f t. Grandfathered: ❑Yes ❑No If yes, attach supporting documentation.
Dwelling Type: Single Family t Two Family ❑ Multi-Family(#units)
Age of ExistingStructure 191 yrs
g Historic House: ❑Yes ❑No On Old King's Highway: EIYes ❑No
Basement Type: ICI Full S]•Crawl ❑Walkout ❑Other
Basement Finished Area(sq.ft.) Basement Unfinished Area(sq.ft) 455 ± s._..;. f t.
., Number of Baths: Full: existing 2 new Half: existing 1 new
Number of Bedrooms: existing 3 new 0
Total Room Count(not including baths):existing 7 new 0 First Floor Room Count 4
Heat Type and Fuel: ❑Gas 0 Oil ❑Electric ❑Other
Central Air: ` i Yes ❑No Fireplaces: Existing 1 New Existing wood/coal stove: D Yes ❑No
Detached garage:❑existing ❑new size Pool:D existing ❑new size Barn:f existing ❑new size
yAttached garage:❑existing ❑new size Shed:>aKexisting ❑new size Other: see Plan
Zoning Board of Appeals Authorization ❑ Appeal# Recorded❑
Commercial ❑Yes 0 No If yes, site plan review#
Current Use Proposed Use
BUILDER INFORMATION
Name :obert H. McPhee/ McPhee Associates, INC Telephone Number (5°8) 355-2704
Address 1382 Rte 134, P.O. Eox 797 License# CS 018520
East Dennis, MA 0264' 104158
Home Improvement Contractor#
Worker's Compensation#dec5002051012002
ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO SF1 Dum s t or
SIGNATUR DATE _ - D
a FOR OFFICIAL USE ONLY •
f
.d
/
— PERMIT NO.
DATE ISSUED •
r
MAP/PARCEL NO.,
rt ADDRESS, , -�' VILLAGE
OWNER ..ef
r - i ,`
V DATE OF-INSPECTION: 7 {
-' , s
FOUNDATIONS isle p ///' �// y >� a
524
FRAME LAC.? G-�-"/ - 0 I- PA '<
1 INSULATION'r'.3"Z , S i"--- 14: '
FIREPLACE r'p ,
' 7
ELECTRICAL:,,. ROUGH FINAL t _
b t
PLUMBING: � ' ROUGH FINAL
,..7.1
GAS: ROUGH ;' FINAL -
ti sic t ,
FINAL BUILDING g figv 9 O A tO 4 (/// V 3
DATE CLOSED OUT gl i •
J 4 t cl
ASSOCIATION PLAN NO. 'i :F
_, li t. 8
n)
•
,.. , .
. __
•
pie 70Town of Barnstable
{yi. �o� Regulatory Services
BLE, - Thomas F,Geiler,Director
k...:._ s6g9• �� Building Division
Fn �A Tom Perry, Building Commissioner
• 200 Main Sheet, Hyannis,MA 02601 . •
www,town.b arnstable,ma,us
Fax; 508 790-6230
Office; 508-862-4038
Property Owner Must
Complete and Sign This Section •
If Using A Builder
fll Q� ,as Owner of the subject property
1, n
McPhee Associates,.
Inc . to act on my behalf,
hereby authorize � . . . '
in all
matters relative to work authorized bythis building permit application for:
210 Keveney Lane,
Cummaquid, MA
(Address of Job)
r
a<
Date
Signature of Owner
Print Name
i
. N tc) I � r
.)‹ No woe
Fes.+ Aoor
‘ 1
P.
a �� ,\ R�� up L,,,. o .
F► � y '�
T `1, ,
A5 ce-eY\
opts,
,
p.,,c,..„00„,\ 1
z i
ct ac r (�
FTp ow)
bN
. ...,
,i,
( ,...,„\,,k,r,,w,...
I, \k,
•
1 L
As Se-9-
,
1 SALT MARSH W '
i , V i
Top COASTAL BAK- .
I B� 1rc HAETT'S MILL POND
I _ 11 _ 1LL (TIDAL)
04I►Q'11 1 i
�'-A
+ X i i '
,'/ CONCRETEI
�.�+ FOUNDATION
9:' + I 1
c) .,K < -‘ i i r' 1
m
---: / I
--- d
.7 i
4 ' 6- -> / 1 \ .
♦ '
i 1
, Ne(1 .
2c m o
-1. 57I w
1 \
$I 8 SALT MARSH \
I
\
1
JOB # 04-147 \
FOUNDATION PLOT PLAN
FOR THE PURPOSE OF OBTAINING A BUILDING PERMIT ONLY .
LOCATION 210 KEVENEY LANE (CUMMAQUID) BARNSTABLE, MA
SCALE : 1 " = 60' DATE NOVEMBER 30, 2004 PREPARED FOR:
LOT 1 PB 353 PG 100
REFERENCE
ASSESSOR'S MAP 351 PARCEL 21-1 PAUL & ANNE
FI TZGe,t a l
,,�P,•,NOFMgs ', ,
I HEREBY CERTIFY THAT THE STRUCTURE �� TIMOTHY cyG
• SHOWN ON THIS PLAN IS LOCATED ON THE ;
GROUND AS SHOWN HEREON. H N
Zo .
off 50e-362-4541 COVELL ;No.38035 ?' •
fax 508 362-9880 "
d% OAP a. •
r �c, w
down cope engineering, Inc, 30 20046
Vaii20±4id .� :-.. -�i/�✓
/
CIVIL ENGINEERS �- -- — �
LAND SURVEYORS DATE REG. LAND SURVEYOR
939 main st yarmouth, ma 02675
I Assessor's map and la-number '3 " ter—
a Z1 — 1 ( -7v
FTHE?
Sewage'�Permit number ?., r. .:.�..... . . , d4 0 g�
5`;-" ci M 1� - n BASdSTGDLE, i
�.. . C'e.-c".ems.
�.�, House,,number' 4� r rasa
6 r-i SEPTIC SYSTE6 CO
4 t •
/' Ql SA• • d C
TOWN:OWN OF BARNSTAtilt? '� CPS H TITLE 5
~,. 1. • ENVIRONMENTAL CODE AND
BUILDING INSPECTOR �` REGULATIONS
` " APPLICATION FOR PERMIT TO t •Cis9_dZ-'ear• r `
,y�1.1 IC IC' C,c J
. .TYPE OF CONSTRUCTION .. �:�I'
• ' . ' ffu-041 it 19 2-
TO THE INSPECTOR OF BUILDINGS: .
The undersigned hereby applies for a permit according to the following info mation:
Location 2-AC) kf C v�.vv v.irlf s .
Proposed Use • - \ .,)
G�� C.
®yam 1 �� r1� 1 ..•Q. '
Zoning District ...f1 C Fire District. � 3!.S!'
,may— �Q �' I
Name of Owner ��,,.�.1... -QV° Address 2\-C) (6 -� �� Q m �-
V. ...CXX. �- Address ...,n,� \ S n5TrAlie
Name of Builder' `l�.1�,.
I LM.SILQd
Name of Architect .L--&_ D 1 Address -� r
Number of Rooms Foundation .
•
Exterior . Roofing
Floors Interior
Heating Plumbing .
Fireplace Approximate Cost' O
// .
Definitive Plan Approved by Planning Board 19 Area l ‘a '
a
Diagram of Lot and Building with Dimensions . Fee `�
' SUBJECT TO APPROVAL OF BOARD OF HEALTH
...CP. . .
\)j
i
OCCUPANCY PERMITS REQUIRED FOR. NEW DWELLINGS
,•. I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above
construction.
1
-
t.._.,
Name _
-� ' ��
FITZGERLD, PAUL Y
A •.v.-
•
* j.• "'2424'2 ADD PORCH
No Permit for i •
CSngle Family- Dwelling
' 210 Keene :Lane
Location :-....- �'
Owner Paul Fitzgerald ,
•
Type of Construction Frame
Plot Lot �*
♦♦ , .:
�.• July 26„ 82 f
Permit Granted 19 `
Date oflnspection 19 't
Date Completed f GT 19
s ,
- t.
jGeneral Notes: General Notes: Drawing Index Fitzgerald Residence•' '\ 1. GC shall be osponsible for a0 assembly labor and trades rested to assisting the vendors who are responsible for - •-
v:. Installation a machinery including,but not limited to:
a}Debris remavafor vendare. Remodeling
j' \ b}Rigging of materials to building and reconstruction of exterior wails as needed. 1. Layout •
v\ • c}Stlnedurng 8 coordination with vendors, t0 Cover Sheet
Keveney Lane
2. Contractor is expfici y responsble for the following aspects of the project
/ \ a}Obtaining combustion permit(rrem approved plane}scheduling end oeainin a0 ancillary a Contractor must lay the entire job out in chalk lines and then track,before buildinganyBarnstable,MA
e ay permits anti sign-offs Al demolition floor plans
(electrical plumbing,lrvAc e0uipmem use parmlts,etc.) walls,and shall obtain owner and architect's approval at each junction. A2 proposed floor I
\ I b}Ordering.picking up or having deivered.and completely installing ell fid'ngs and Postures to be bought 0y Owner. pails
+ -'/ ' c}Ordering.obtaining.and nsta6ny fetish matelots and colors to be selected by Owner. - A3 reflected ceiling plan w/elecbical
i !/ 3.The contractor shall be retained by the client with One explicit understanding that the contractor is an expert Inb. Contractor shall mark all outlets,switches and light fixtures on the floor before any A4 existing elevations
210 Keveney Lane I residential mnsbudlon,and that he snap employ this expertise in the detrnnna im of the mil scope of the project.Any electrical work is done. Owner and Architect must approve or alter this layout before A5 proposed elevations
Map 361 and alma mails nonnaay macrame wan the construction shalt be included n the contract even a t s not shows n beginning work. A6 schedule
�/ °0 ' /' Parcel021001 / I themno-aadommenb. THE BUILDING STUDIO
te,
moo;i40t. 2..Co-ordlnatlon:
.F, -•
a. Contractor shall distribute to subcontractors full sets of drawings for bidding and for The Building San&LLP a Awhioxrure&Design Senirex
:/ I Scope of Work Notes. work, 307 West Floor York,NY
j / �/ 1. Work involves renovation of an existing two story single family wood frame home. Telepiaedza-nv.l3oi Fax z1u�.lsal
< There will be NO CHANGE IN USE EGRESS,OR OCCUPANCY- b. Contractor and his subcontractors are fully responsible for all co-ordination within this
_ Area 0f work •• •" I n 2. Existing egress.light and air we be retained.
// \ set Any work shown anywhere in these and attendant documents shall be considered an- a.an p ovtanns of Massatl asetls ea ring code and effort mole snag apply. integral part of the work. Even if work is not shown in all places,or is listed only in text,
903
contractor shall include it in the work as a part of this contract,and carefully coordinate it
�' ........
with re'gd trades.
• /' \ Controlled /inspections:
/� c. Contractor is required to maintain a current set of as-built drawings at the site,and to
l��/ /' `� I v\ 1.Foundation/Footings
l 3.Framing distribute these to the architect at the end of the work.
3.Insulation
`� 4.Electrical(Rough and Finish) .
6.Plumbing(Rough and Finish) , d. Contractor shall survey all existing conditions and conform them to the intentions and
`� `� 6.Final Inspection
• goals of the work described herein. Any demolition,relocation,schedulingservice /� _�
\ Historical Not• es: upgrades,temporary removals/reconstructions,work in adjacent spaces not shown,and
/ t � �_._,
any and all other work required for the proper completion of this job,In conformance with
(./ (J// J�
The snipe of wort on this application is the design intent,shall be performed as a part of this contract without extra charges,even En
`\ if this work is not specified herein.
210 Keveney Lane Map: 361 Parcel: 021001 •Raise existngroof • APR 2 1
Site Plan Scale:ins -new exterior windows and doors e. These documents Illustrate the intended final result of construction work at this 2004
•Removal of Skylights
ew ge rema encloses porch
site. The contractor is solely and completely responsible for determining the exact
ineerbmenovatlone scope of demolition,salvo a/restoration,and/or reconstruction work to be -- --- .
undertaken at theelte. g H STpRl0pRESESTAI3LE
Special Conservation Area Notes: 3.Owner will be living in the house for the duration of the project Contractor shall R�A t IpN
completely protect existing house areas to remain untouched,allow for provide temporary
I. work proposed Inthis application involves minor work and extension In the wetlands setback area kitchen facilities,and otherwise accomodate the owners needs during the work.Clean the
2.Conservation application will be fled for the proposed work site daily to avoid mud and landscape damage,and an unsightly environment
•
Existing Conditions Note:
' 1. Contractor is required to do a thorough survey of the jobsite before tendering '
a bid. No change order requests will be approved that emerge from field
conditions that could have been observed from a thorough field inspeciton.
' General Scope of Work Notes:
1. Replace all termite-infested wood if found
■ 2. Remove all chi
Aping or peeling paint; take all necessary precautions againstFitzgerald Resid en ce - leadpainttoxicitytolaborersandhomeowners.3- Replace all damaged structural members,including but not limited to beams,
bearing walls,blocking,bridging ledgers,roof joists,sills and lintels.
Re O d e lin g
When removals or relocations are indicated,provide temporary shoring,
work to remain that occurs because such shoring was not done shall be rebuilt
like new at the contractor's sole expense,within the project schedule.
t
•
5. Where roof removals are required,contractor shall provide full and complete
Keveney Lane • _ temporary water protection for the structures to remain. Such protection shall
1 to roof
be wind-resistant and shallbe set In place at the completion of each days work. Scale: n.t.s.
Every effort shall be made to protect the existing structures to remain from Date: 12.15.03
Barnstable M .■ s went pipe waterinfiltration damage during construction.Any damage due to weather Drawing Title:
Tor conditions shall be repaired or rebuilt as required by the contractor at his sole Cover Sheet
I cost,within the project schedule. Site Plan
-
and Notes
6. This set of architectural drawings is not a complete description of the
I full construction scope of work at this site. The contractor must Integrate and
. master m 9 -
2nd floor coordinate the mecahnical,electrical,plumbing,sprinkler,fire alarm,structural,
4•die.waste new
new
a• , equipment and other requirements into the architectural drawings here
ape Tvp to fully see and evaluate the full project scope. No extras shall be approved
- that emerge from the contractor's Improperly coordinating the various
•
documents comprising the scope of work for this project, No changes to the
•
architectural design of the space shall be made without explicit prior
approval of the architect,for changes required in order to accommodate
•
I coordination requirements.
1st Drawing Number.
Riser Diagram Not To Scale AD
e-hwaovngead ow 'ronu w h lsm a n aisPeessssl y - r
n
r
•
•
•
Fitzgerald Residence
Remodeling
(
•
_ Keveney Lane
• Barnstable,MA
•
Existing House
(No Work) Existing House •
• (No Work)
openexist walls as req'd.(typ.)
�.RoS TpT " remove skylights
•
% _ _/ THE BUILDING STUDIO
i6 '' The Building Studio LLP I l ArMueeiure&Devi,.Servi tie
°Y�' E E f 307 West 38th I7th Floor New York,NY 10018
NOTE:SAVE ALL OLD BOARDS I'rA! I 1 Lynam Rd. Stomford,CT 06903 FOR POSSIBLE REUSE AS Telephone li - O.dry -. FLOORING AND TRIM AT NEW remove wall W one 212 279.1507 Fax 212279 1561
\ $ma remove shabs WORK AREAS
I
i'i overhang to remain 3l
Q x remove existing ExistingBedroom remove sun
Dining Room Sun Porch h;r4, sun perch (old PrueFwortoRamain> porch tip/
(No Work-protect as required) (remove flooring
/ and windows) ,I1 d -
r 1
remove door
a: .. .'. a vs
a
•
.rEj` remove
extent of(YP
•
_ oat . w D n
ss
1.1
o exist. {. ponron as raq'd ".:..'.-" ii lit ' °
r ::s= re n I U pen (en.) •
Li
remove end relocate existing / 'r I f-----`� �F l ---- ' ,t
door,patch as req'd , ` L--__--j '- ---J --;� remove extent of walls �O w"" (]
roof overhang above �V __ as needed(typ.)ire - overhang to remain remove closet. _ a windows(typ.) ����OR/!v p-, �l�N(1 TA p�
(to remain) doors and wall l.r!_ SER
f fli7 f F
N
Closet • f l
Study Iti
Bathroom Kitchen Terrace d•
(Remove Floc) y;
llLI (No Work) (No Work) gggyyy���
° li 1 remove extent of wets
Laundr� •
13,:--_ (lye.)
1
• (No Work) ��Bathroo I
/J xist windows to remain
open exist.(typ.)----- e open exist(typ.) . - relocate vent
verity location remove extent of roof,walls .
• &windows(typ.)
remove door,fixtures,file
finishes and floor.
•
1OExisting First Floor with Demolition (I)Existing Second Floor with Demolition
I/4-=r-0- va._1.-0.
•
GENERAL CONDITIONS
1.The General Notes of the AIA short term contact recent edition,for small construction shall form part of these specifications. DEMOLITION NOTES: • CONSTRUCTION NOTES
2,All work shall be Carried out in strict accordance with all applicable laws.rules and regulations and the Inspectors
requirements. 1. It Is the general intent of this demolition to resutt U e space that is ready for new ESSENTIAL SERVICES:The essential building services in the immediate
3.Contractot(s)shall obtain at required permits before commencement of work and pay all requited pert fees. construction work work areas must be maintained(or only temporarily disrupted)during the
4.All plumbing.Mechanical.and Electrical work shall be performed by qualified licensed contactors.The contractor shall be 2. All work performed nil comply with Building Codes and all other applicable codes. construction project This includes Water,Hot Water,Electricity.plumbing and
responsible for all fees for permits,inspections,and final approvals. 3. Contactor to and schedule at necessary Inspections.Contractor to prated masonte(et telephone.Services to the unoccupied back area may be disconnected.
5.Contractor(i)shell have their work accepted by inspectors having ryristictioe. fkar)and peper(at walls)to prated surfaces and spaces not under construction. Scale: 1/4"=1'-0"
6.Existing conditions shall be particularly dear to General Contractor before submitting bid.Carefully examine premises before 4. Removal of non-load bearingOCCUPANCY AND to the owner Extreme ply theen hate taken p avoidety
submittin bid.No allowance wit be made to the contractor for lack of full knowledge of ail conditions,except those which are partitions de Verify for demolition
ntwork ding theh. ki kitchen g any abilityta ld in to rainy premises.A temporary Date: 12.1$.I)3
9 9 P 5. There will be no one occupying spaces designated for tlemofMon work during course may need a bet in an
r the main house while the work is underway. Drawing Title:
Indeterminable before the commencement of work. of demolition work. Work shall be carded Out U an orderly fashion to avoid disrupting their
8.Contractor shall et all times be guided by dimensions on plans and not by scaling off drawings.Contractor shall consult g. Coordinate with owner the shutoff of services as required during execution of work ' Iivingspace In the main house as possible. Demolition Floor Plans
erchted in case of discrepancy. 7. Furnish temporary lighting throughout space to meet codes as required. DEBRIS:All debris shall be removed by Contractor in an orderly manner.
9.All notes on Cl drawings shall be the responsibility of the General Contractor. 8. Provide temporary smoke detectors as required. Dumpster location on site to be coordinated with owner.
10.The written approval of the Architect shall be obtained by the General Contractor for the substitution of methods or materials 9. All plumbing and electrical work to be performed by licensed plumbers and electricians. SHORING:Shoring is the responsibility the Contractor.The Framing
for those speeded before such substitutions are made. 10.Al debris and products of demolition shall be removed from premises and legay contractor and Foundation Contractor shall have experience with this type of
11.Contactor(s)shall check end verify at measurements and conditions et the job site before start o/work end shot be disposed of project and restoration work on old houses.
responsible for same unless at discrepancies are reported to the architect in writing prior to the commencement of work. 11 Al pktmbbmg fixtures to be removed as required
12.1n the event of any discrepancies,errors,and/or omissions in the drawings or specifications,the Contractor shall seek the 12.Cap and CONCEAL al exposed wires.
written approval of the Architect before proceeding with twit.In the event of discrepancies.Specifications shall supersede 13.Remove al extraneous Pipe,conduit.tubing,wood,rtaMings,plumbing from at ware. •
Drawings. beams and ceilings if not required for completion of work.Contactor to carefully coordinate. •
13.•Afgn•as it is used in these documents shot mean to accurately locate surfaces in the same finish plane.Where new 14.Remove existing flooring and undedayment as shown.
•
surfaces meet existing surfaces no visible joint steal be detected. 15.Remove any eat coverings and scrape loose paint from wags and cams where
14.Verify or V.I.F.•as it is used in these documents shall be verified in field by GC prior to commencing work and Architect required for
steal be notified for any deviation requited from the design intent proper finish throughout. .
15.TypiCar or-Typ-as used in these documents shall mean that the condition is the same or re 16.Remove telephone cables in coordination ttilh tracks
from
an.Contractor to tea.
conditions. Presenativa for at similar 17.Contractor ahal remove et floor and coifing backs from demofishee partitions.
16.PREPARATION:All surfaces shall be properly prepared and patched for smooth finish.Where new censtradion meets old, •
1u.Contractor mart exercise care to avoid damaging existing building finishes to remain
during demotilion;proact surfaces as needed.
careful alignment of seams will be required for Flush invisible joint. ,
17.CLEANLINESS:Drop Cloths,careful aping and dosing of openings shall be cooled out by Contractor to minimize dirt,dust,
and debris intrusion into adjacent spaces not under construction.
18.INSTALLATION All materials shall be installed in conformance
nfoance with best industry practice.Contractor shallinclude all usual - Drawing Number
• materials required for proper Installation/assembly in bid whether specified or not
•
Al
Znym ec5Mtmsesw'saaaW Bamsuneoxgst flngpeo_FFLL°levawa •
/1
Fitzgerald Residence
Re
Keveney Lane
Barnstable,MAmodeling
Q.
Existing House 2 new gliidingdoors Existing House
' (No Work) (No Work)
O new Wall in owsawn a e
5 / • veng
ntlng windows above
•
v l I ���1 1 1, �p i'I I ���I�I1DI�U —', v THE BUILDING STUDIO
v 6'-0ll IIiI)� riot_ I Iill 1��,I
2'$' 6'-7'3 I I i Jl 0I� The Building Studio LLP Architecture&Dogn Smhrr
\ W 307 West 3BM I Th Floor New Nod,NY 10018 II u / ( 1 Lynam Rd. Stamford,Cr 06903
II • N�,�I�Alf�l��, 7�I^�IW Telephone 212279.1507 Fax 2122791541
f Existing Bedroom � lu�`�u
J H
r. u_ 4 n n (save old pine board floor) • "I U
epO�
1 Dining Room Sun Porch �j 0 0_ ' II �I���
•A .�""--������"" (No Work) new gliding daa'rs I i — I I��I� �� E I
.I 5$Y
L? --.
B 4'-10
iI, 1. O1 pW1rl�(��1� ,
to
^efrepogsa ! new wall
ell sb'rng \ i 7'-2' 2'-B' O 111I xYt1I�0°0 J
I'991' /ii O ,, f A P� 1 2004
patch as req'd C I�I'11/1V'
F
z tmn��aau.r 1it .dIV.;Is�el relocated 'III m n N O — 'g�, Closet ' 7 .o
ifhV///)4i TTT ^�, TOWN
lEm
exkLcgor II - Bathroo •''e� HISTORIC PRESES TAB LS
open ceiling for plumbing 2 3 W •
it
/ _ algn with face of existing yy (�
iO 1 route through closet and O `v tYilll ai►0�� iv n ��I ION
dal aa� rA� Ili eW r00(OVel neW LEGEND: ,V
existing bathroom as pose ���`- B extended sun porch «
is for concealed finish new post if none exists "C��� I O EXISTING woos
\ .L tit_J� 11111"011
Wilk In area of extended footprint
_== NNEMNWALL H
Iv'
■' ■' Closet NEW WALLS
�\ II \� ,. = area W extended footprint i.u !�t ;! o EXISTING
RSINSossouuTE
ENS G qm
•
Closet •••
VISULATx2N SCHEDULE.
Bathroom Kitchen = Terrace I I _ °O zew�s aye
II O (No Work) (No Work) (rework masonry as required) Q�,� _ 2n12 FLOORS/ROOF
Tv • •-�' 2nne FLOORS/ROOF .,
Q • III - dSt dy • ALL CATHE CONTINUOUS
CATHEDRAL ARE.VENTS AT
;Q -
t (use old pine'•.-hied floor) m -EPA I s�vnro BwawE t AT
Laundry • I,ri ��� ., • • INTERIOR UNDER cxa
•
(No Work) N
roof overhangaboveL.". ensl wdws exist wdw5
eq. 4'-3' 4'-5' 4'-3' eq.
now post if req'd \\\\ `insulate 8lyvek(typ.) new post if req'd - - / .�' .' .�` .` / •
d - 12'-2'vif ?6" J" d _
O Proposed Second Floor
OProposed First Floor 3,aY • , 2 1/4-=1,0" 'v '
•
DOOR SCHEDULE
It Is the responsibility of the contractor to verify sizes,configurations and locations with actual field •
• - conditions prior to order.Contractor shall mark out all rough openings exterior and interor prior to
RFINISH NOTES:ROOF.R ordering for approval by Architect.Contractor shall make small location and size adjustments to •
ROOF:Red Cedar select rejoined and rebutted dear shingles over _ • reflect field conditions as required. ' d'
cedar breather fabric,305 asphalt paper. '
At low pitch areas or as allowance:Asphalt Menorline or equal highest Symbol bescd Size
' quality architectural shingles. Finish Schedule Sin ptle^ Model*I Quantity
Provide snow and lee shield at all vaneys,eaves:dormers,etc 36•up Rebooted Fog.Door
Level Room Floor Walls Base/trim Ceiling Ceiling Comments 7 3'-0'x6'$" - 7
each side to prevent water infiltration from ice dams. molding Repair&refurbish
Use copper flashing throughouL -- -
Trim:Painted wood to match existing.Typical colonial flat casing(1x4) Ground Floor Sun Porch Bride Beedbd Painted beseboard patted •
•
Antlersgn 400 Series
at windows to match existing. • O Frenchwood Fixed Unit 4'-2"x 7'-11' FWG 43808 1
Sheathing:Repair/Replace with matching thickness to existing(3/4- NOTE:Repair and refinish at disturbed areas.some ceiling work at areas of piping,etc. •
Insulation:sea schedule
Housawrap:provide housewrep moisture Darner,flash with 308 tilt at _duel Room Floor Walls Base/trim Ceiling Ceiling Comments O Anderson 400 series
• Frenchwood Gliding Patio Doors 8'-0•x 7'-11' FWG 808OL 1
all comers,Wm and window surrounds. molding -
Flashmg:Provide copper cop flashing Cl at horizontal wood surfaces - Second Floor Bedroom EXG. gob painted gob 3'crown existing old pine floor to remain Scale: 1/4"=1�-0"
above trim. O Anderson 400 Series
Sidewalk:While cedar rejoined and rebutted dear select shingles or 4 Frenchwoud Gliding Polo Doors 15'S•x T-tt• FWG 16080-4 1
JO g Bathroom Tile wb/d painted cob 3"cram - gDate: 12.15.03
Clear select cedar dapboanl to match existing house as shown. g pain e g
Windows:See schedule Drawing Title:
Doors:Sea schedule Study OLD wood gwb painted gwb 3"crown new old pine floor use reclaimed boards as pores O Anderson 400 Series Frost watt Rebuild and repair as needed. Frenchwood Gliding Patio Doors 6'0'x 7'-11• FWG 6068L t Proposed Floor.Plans ,
Footings:Repair as needed. Wank it Closet OLD wood gwb painted gob 3'crown WINDOW SCHEDULE
new old pine floor use reclaimed boards as pores
It is the responsibility of the contractor to verify sizes,configurations and locations with actual field O Bedroom Closet '
conditions prior to order.Contractor shall mark out all rough openings exterior and hearer prior to 6 Sliding
Doors-Get 5000 track 4'-10'x 6'-8 ,
INTERIOR FINISH NOTES: ordering for approval by Architect.Contractor shall make smut bcetion end size adjustments to
reflect field conditions as required. Bedroom Door
Ceiling:New 1/2•greenboerd with vaporbaier throughout.Refraree .. _ O 4 panel fir brass hdwe to match 2'-8•X 6'$• 1
rind adjust strapping es required for level finish throughout space. Symbol beserlptlon Size Motlel0 Quantity
All beams,soffits,etc to receive pine painted sheathing/trim.Bead Anderson 400 Series
bottom edge for traditional detail • O AwningVentingWindow 4'-0-W x 2'-5"H AW41-E 3 O Bathroom Door 2•-8"X 6'$" 1
Wails: an• t gwb with vapor Denier and insulation o 3 1/2'Datt min. 4 panel fir brass hdwe to match.
• Beadboa wainscot,chair ran,baseboard and casings to match - •
• , �+"
• ensiling and as shown on plans. •
Anderson 400 Series
• 9 Tit-Wash Double-Hung 2'$"W x a'-0-H TW243,0 5 Welkin Closet Door
Floor Use salvaged moisture-cure
boards final demolition to TbN match OWindowsO2'$'X 6'$'
existing.3 coats mpisNre-cute catalyzed umthatne SATIN finish - 4 panel fir Draw hdwe to match
Tile al Bathroom to be thinsel-While matte ceramic ex8
6 O Anderson 400 Series 4'-3"W x 4'-0"H
Tit-Wash Double-Wide Units Tw20310.2 2
Drawing Number:
s Anderson 400 Series .
O 5'-0"W x 4'-0°H TW26310.2 1 "
Tel-Wash Double-Wide UnitsExtend Doors Andersen 400 series doors with pre0mshed white Interior,polished chrome or antiqued
=extenofintenor 3/4' . estate hardware and
keyed
entry where where shown andinsectlots 000.high performance glazing,Permanent A^
•
L
NI Windows to be:Andersen 400 series windows with prefinished white interior,white hardware and Interior doors:Solid 13/4'wood(four raised panel)to match existing on three 412"Antiqued Brass
. linge^ifk,low a high performance glazing,permanent extenorinterior 3/4"mullions and insect•
hinges.Painted finish with Andqued balowin series Privacy knobs.
LbroHraFMuxsTitzgereld eemstadeV.8..9na1E_F.4..a+9 r" sOeen4 •
4
•
1
•
,.,„ ,..con
• • Fitzgerald Residence
•
, 11 Remodeling
mil' ; 1
� ,I ' Keveney Lane
• � — - -- ---�------- - Bamstable,MA
�+
Existing House `® 1 -- _ '311.,
(No Work) I ;1 — — -
I 1 awn 1= 1
3 xlo M header as possible - - — — THE BUILDING STUDIO
_ i, '1 - ,
I I --'-3'-loll
a�T'I IfI� I • r 1 i I The Building Studio LLP I Archuerrure&Design Sm'&rr
1 1 , I I 307 West 38th 17th Floor New York,NV 10018 II 1 1
�� E I I `� 11 �,I, 1 1 I I Tcicphone 212 2]9.130]�mFos 2111909.1561
zx10r.@16•o.c. m zxlo•s(�1s•o.s. ;3 I I 2x1c'sf16•o.c. I .L. ff J iI$ m I I ' �, ( jr l r �, I JJ i
z ._ ._........... ._...... smogs I I doge vent gyp.) a I 1 1 1 I I I I II I I I it I I 1 i 11 I 11 new ousel our
(Below) I I I , ' III /
, I
• Exiting Bedroom o I I h 1 1 I , 1
I I M (1 7� t J , l' N new roof over sun porch
.� I III � 1
2x105416•o.c. 2x1o's®16•o.c. I I 2x105@16•o.c. ` 1
I I new wood gutter 6 leader 1 1 1 I I'I
11 II �3x10 M @porch I j III I 1 1
2 3x10M across _ �.II 10I .I ,1 t 1 / I 1 1 I _ I I
1
111 - Cbset _ i, ., 1 U I II I )� 11, --1 IrS'_n
I!?�o • 41 • -/Ilnew wood gutter 8 leader .
I _Bath m cwsecftfl 1 s 1 Ls P y �."^1' 1:4_,...
`t resningle exist.overhang I�y III 11 -- I ` D [ 1\Y L=7
2z105�16'o.c. 4II- ppll II',
. I11 .III h�11,�,�
2x,05Q,6•e.c.- 1 „ I r� ', T new raised roof APR L 1 2004
Study , IIIII o1 1r 'i,ry` iqq
I: TORN OF BARNSTABLE
•
�' �� I i1 a HISTORIC PRESERVATION
• new wood gutter&leader_ N11JII \
— strap tie continuous top plate an around
• to resist thrust bads(typical a0 sides) • new wood gutter&leader
4 all around
Second Floor Reflected Ceiling O Roof Plan
OPlan With New Roof Framework • 2 1f4•=1,0'
114•=1,0'
2x12 ridge bracing each joist.stagger bolt through •
for rigidity in lieu of collar ties
2x10 Joists,Baffle vents and insulation
12
3.5 v'd Gutter across
i i �".` ,'r• New window and beams across
mil
i _
i_ ��.`IS 2x10 Joists,Baffle vents and insulation •
• •
''1i Existing roof to be removed + Scale: 1/4"=t'-0"
�� . 2x10 Joists,Baffle vents and insulation
��Ateadboard ceiling at inside Date: 12.15.03
i �1 Drawing Title:
\ 12 Reflected Ceiling&
Master Bedroom
11111
----13.5 vif . Roof Plans
Wood Gutter
1 JO
l New gliding door
e .,
Existing Kitchen Sunporch11
(no work)
Drawing Number.
• O SECTION A3
ZW,¢Iewo-hws flFi¢9atlE eeore&te\0,.sw 11¢gno_Flnlpon.¢p
•
• Fitzgerald Residence
Remodeling
Area or Work
/ / / Area or wodl Keveney Lane
intersection• adjust Bamstable,MA
i ,i,r at eaveo.p vloe continuous support LVL ridge above existing it 4, -
ppod below existing eave sill _
•
costing dormer to be removed,motto be raised existing reof to be raised do not at any post rreming timbers. -_�-
/ / / —__.:_.___. — - • new raised roof _ —
cedar rasphaa -
existing skylights _ __ _ new awning windows Ea11a.� .
to be removed
Z = — — — _ _ _ _ _ -
�� — — — — — — _ -..... - - _ _ THE BUILDING STUDIO
+rt�✓ r�.�.`.a..... — — — -..� T--—
IMMI
! _ ' I� - y 1MIllff1110111
' moomm
ilding&wile LLP II■„ lt1J1Ju1** I±kt!1JH!
■!I mmee
MN MINI 1111MINIMINIMIN• I•111
=Ini
M I■■�I■■■I = EKEI■■■II■■■I fixed axis .acrylic glazln. _________________
Pli- 1n F ,. 11 ti 7,A, k l .',=�., lit. I�• . i>tilrrr •1
lPEP11 14 0,21Ei1MRWla! !1 Y _ r1' •tr_■ ��N hill_
'INex sting windows to remain . - glass doors
existing stone wall modified as required •
• -.. � �
EXISTING NORTH ELEVATION PROPOSED NORTH ELEVATION
1 e t/4'=t'-0' CI)
1l4'=1'-0
•
APR4
To, 1 2004
H�sro O�g4RN
PRFSE,9v 81.E.
— ---Area orWork _ —
II ■■■ -
existing sun porch to extended
;voile be raised
new roof and clapboard sheaMinged 3�- 7 ' _
/
_ g,ll a a Scale: 1/4"=I'M"
■■■ new Date: 12.15.03
faedexs�gacryticgazng n \ Drawing Title:
(to be removed) \� ■■■ .
il ��� ....."Tilli .
\ I Existing and Proposed
Elevations
OExisting Rear Elevation 10 Side Elevation
Drawing Number.
A4
•
•
Z,ympot-howwluaarau eerneutle,L.p,lUeme 0-Fus.ow.e+y
Fitzgerald Residence
•
Remodeling
' Area of Work
existing roof to be raised Keveney Lane
Barnstable,MA
n
=tom •
— --- - — _____rr � new to and reorpltch
fC99YYYP� -� _ �5=_-__ y T _ __ — — ew windows_
.412 Q9Qa1 — ____---=- _-T —a = _ _-
- ,—_ - -- --- �.__ — � _� — _ .:r' _ _ — new clapboards
E�is� Lr�_ cW bo
— — — — — — �_ - THE BUILDING STUDIO
a• I � — 307 west 38th 17th Floor New York,NY 10019
mmo■■■� ` ��•� ... The Building Studio GIP II Architecture d Peale Service,
■:�I A i.d existing windows IL�ri_�I _ IIIliir111111 ILynam Rd. Stnmfoni,CT 06903
MI It\I III. [. _ _ Telephone 212.279.1507 Fax 212.279.1541
�\\I \\\► r fo be removed = „`N.IO\II ••\\II.
AMMO III\I\. �` _ IIUiIi-
�I\\I\O �IIIVI�
AIvI■\IIaI '.II\\\II\, new roof antl roofpHch
� 12
�vl\\uII �IIIII\II► existing sun porch to be extended �3.5 min ^
All\IIIIn1`JIII \I \IIIreplacedr I' 7 I JrII 7IJ IIIIIL
roof to be replaced
•
l l i III lt1 1 1l1fff 1II I I I , -
�\\III _ - MI♦� ' �Itl♦ ��M —
um\Iu MOM l .w ■u■ ■I■ - - ■M■ ■•■ ■•■ __1 ovuvl ■.■ uut ■�■ ■n■ _ y
omm10DI ••• •• I I II ii A I EE
-
J I vII\Iu ... OIIuI fixed existing acrylic glazing — .
:::�.�::.(elf 5f �Y�iIL (�� 1 it [f t� / (to be removed) _ 0
� i.
I 1 '(1'frfff�Sill f 111 11 I 1 u� t� -
• ��. � I T 1
IL III I I \ ,
I Ia,t o,ildie q UMW AM
Lill\ . . . i-
• sir ;r 7 G,-
existing door to be removed new glass doors
OEXISTING EAST ELEVATION O PROPOSED EAST ELEVATION
1 1/4•=1'.0 t/4•
IECE QilfE
- Hi° 't3F
• Oft PiFR RSAe
Area of Work -
. iJ b
�^ - - 'fd a
w Ill
existing roof&windows to be rased existing dormer to be removed,tool to be raised - _ — �� — NOTE:s.just intersection of new support
below
above g eav g sa
at eaves.provide continuous support bebw existing save sin
�A -- _ do not cut any post framing timbers. new roof and roofpdrh
r _ _ )/ ��`I3.S min new wattlows
- - - -_ __ _ — _ y i - new dapboads
,,, III C r / existing mot overt,ang.
,,, illEN
;I••-'I���I�.I MI6 11 __ existing windows
MIIIIIIIIIIMIIIIIIIIIIIIIIMIM C ;` �-- -�. ___ — �-=r— / relocated existi,g door
Scale: 1/4"=1'-0"
Milli Jill III _______
ii!
imill = , 7- DmwingTitle:III
I___ ____
_ii t Proposed Elevations
iiiiiisiim I •
.:,existing Boor to be relocated NOTE new post in this location for structure above
•
e O EXISTING SOUTH ELEVATION • 0 PROPOSED SOUTH ELEVATION
va=r-0
•
Drawing Number.
A5
ZlpmjeWl-lcuaeatFmeerodlikons elpelnl5¢gralbenmskw.ewe
1
ter. ,6.1P. �. .
'� 1
MILL LANE
i
6 wLL CREE►c7 "
1ULLEITS
MILL CREEK - "" ►uLL POND
/ \
\ I
Locus
i „3• /
6.4) �' 5.4p11.32
if
N.
Alt
ROUTE w
SALT MARSH I /
ifF /
// LOCATION MAP NTS
8.67 i /
/
' +9.10 A32 •14 13.66 A31 �2 / ASSESSORS MAP 351 PARCEL 21 -1
JA A33 29. A30. / ZONING DISTRICT: RF-1
.10 ' TOP COAS •L BANK 8.7: // A28 \
YARD SETBACKS:
A34 3.75 i ':��� A',d _ .. .e 9.336�, =
79 +14.92 / •93 -� - "-' _ • 03 FRONT = 30'
/ SIDE = 15'
�, 3.11 /-1-
o -6 i REAR = 15'
X• ti0h /1�, t 1.4� 27 PLAN REF. - 353/100
A35 12.09 $ • 1 ` 68 HALLETT'S MILL POND DATUM: NGVD
_ ;.6 13.78 (TIDAL) FLOODZONES A3 EL 11 AND C
,ri3.76 \ '27 gi 9.18
/
1416 4.09 \A36 14.03 / •• -
S. , �`
+9.46
S,. / 4 �� ' I \ c 1:.2. =37
/ � Y'� S.13 .7 •s
i /' I I 11.38
.09
�$ 15.- '15.81/PROP. E TE ,•• +t 43
0 ,� / TO SUNR••W r
LEGEND
.
I � 19.:3 I r 1115.67 A 19 WETLAND FLAG
1 `„, // ` : .30 I Q .17 % 6.98 i
g i , I
9$�/ / �� DWELL. ;$ \ N A �` 11.3 % o.3 y 6}12 TRANSECT
2.a2
I J
/_./ - -. N i A24 /I
+22.10 '. .1' FIRST FL. / ( -.-...`�'7~i. ��' I 10.28 .
�+- .68 EL. 24.9' /_: Z� r1.7S 13.3 SPOT GRADE
2.
•- ----,..- .- - FLAG. ' 21iir-c1.24 R.,
*�.70 - - -.. PATIO
T�NF �R� / /
2 t3 / . '9
PORTION OF EXISTING **2.Z:25 / • A23
DWELLING TO BE ` '1-482 235 4 / �34 ` 11.33
MODIFIED (REL:OVE ` -4-�'3.66 T i C .2) .i 63
AND RAISE ROOF) ` / \ =.26
2 s / o�4'� 17.0: .
'
2, h^ ..1 \ '
4, ..
-• SITE PLAN
1/ 19.05 '°0' / OF 210 KEVENEY LANE
I ilig
kil74 IN THE TOWN OF:
+1- 44 +(`4 (CUMMAQUID) BARNSTABLE
S a -
%.30 .67�
...\., I 8.30
\X i 7 I P PREPARED FOR: PAU L & AN N E FITZGERALD
'-
9 +'+ a ,6431
I I ,Q \
II Ali 30 0 30 60 90
1--1f--a t I I
• 8.40
/I �!---)
' 0 611.54 SALT MARSH \.66
+14.41 `' A19 SCALE: 1" = 30' DATE: JUNE 22, 2004
1 \
11.60
,\/2., A18
N.' Alik• ../A1� 29 a+ aoe-x2-4ss1
Im SO!362-9N0 ZOF/�L � SNZO /,,
14 A15 \\19 �
A16 ' I d ARNE H. '& I/4) AR NE
clown cape engineering, inc. (g. •JAL/4' I
12.85 CIVIL ENGINEERS -��o tv. �26348c
A13 LAND SURVEYORS o� , µ* `_� °A-e 1o4' '��
P
04- 147 1 939 main st. yarrlouth, ma 02675 ' "! �!4'_.,N°•JALA, P. ':`- °' DATE'