Loading...
HomeMy WebLinkAbout0042 OAKMONT ROAD �� �' ��. a n: � �. .. .. - .. III ;� ' V e +, e� n, a ;i $F Town of Barnstable Building PostThisCard So That rt�s Uis�ble.From;the�Street Approved Plans Must be Retain; d,.onlobapd this Card Must be Kept 7 ty s639. 1PstedUntil F�na�l InspectionHasBeen Made ;, t zy Permit ° 10 eh ire<a_Cert�ficat =ofAOccu ana �s Re aired such Bu lilm shall Not:bea:Occu red unt�I a F nal�lns ection hasp-been made ': µod ,, Permit No. B-19-2466 Applicant Name: William McCluskey Approvals Date Issued: 07/31/2019 Current Use: Structure Permit Type: Building-Insulation-Residential Expiration Date: 01/31/2020 Foundation: Location: 42 OAKMONT ROAD, BARNSTABLE Map/Lot 349-053 Zoning District: RF-1 Sheathing: r Owner on Record: ZAZZERA,STEVEN&SACRAMENTO, Contra�ctor`Name: William J McCluskley Framing: 1 Address: 42 OAKMONT ROAD Contractor'La cese 102776 2 CUMMAQUID, MA 02637 Y Est Pro ect Cost: $4 800.00 J. Chimney: Description: Add R-38 fiberglass, R-10 rigid insulation,and R 26 cellulose to the permit Fee: $85.00 attic.Air seal the attic plane with expanding foam General Insulation: weatherization. �FeePald $85.00 Date 7/31/2019 Final: Project Review Req: - z p � r Plumbing/Gas �p2� � A Rough Plumbing: _ "Puilding Official Final Plumbing: This permit shall be deemed abandoned and invalid unless the work autho�aed by this permit is commenced within s z moo nths feer°issuance. All work authorized by this permit shall conform to the approved application and thejapproved construction documents for wh ch this permit has been granted. Rough Gas: All construction,alterations and changes of use of any building and structures=shall be in compliance with the local zoning by taws and codes. This permit shall be displayed in a location clearly visible from access street or,road arid shall be maintained open for publid"nspection for the entire duration of the Final Gas: work until the completion of the same. � Electrical The Certificate of Occupancy will not be issued until all applicable signatures by the Building and'Fire Officials are provided on th s':permit. Minimum of Five Call Inspections Required for All Construction Work.i Service: 1.Foundation or Footing 2.Sheathing Inspection Roug h: 3.All Fireplaces must be inspected at the throat level before firest flue lining is installed 4.Wiring&Plumbing Inspections to be completed prior to Frame Inspection Final: 5.Prior to Covering Structural Members(Frame Inspection) Low Voltage Rough: 6.Insulation 7.Final Inspection before Occupancy Low Voltage Final: Where applicable,separate permits are required for Electrical,Plumbing,and Mechanical Installations. Health Work shall not proceed until the Inspector has approved the various stages of construction. Final: "Persons contracting with unregistered contractors do not have access to the guaranty fund" (as set forth in MGL c.142A). Fire Department Building plans are to be available on site Final: All Permit Cards are the property of the APPLICANT-ISSUED RECIPIENT ONL:LNjE l�l�'LLiGL�-- StN� Cape Save Inc. 7-D Huntington Avenue South Yarmouth, MA 02664 Tel: 508-398-0398 Fax: 508-398-0399 8/14/19 7i d O Brian Florence CBO Town of Barnstable Oil Building Division 200 Main St. Hyannis,MA 02601 RE: Insulation Permit 19-2466 Dear Mr. Florence: This affidavit is to certify that all work completed for 42 Oakmont Road,Barnstable has been inspected by a third party Certified Building Performance Institute(BPI)Inspector. All work performed meets or exceeds Federal and State Requirements. Sincerely, William McCluskey Town of Barnstable Building +CDs, `.""�;.-.� ;?��r w �:f'' z; ..�..� � �, ' 5.'�. �nY' •� '� ,;' �:.,� :<�'' :' ..� �'..F;�� , a ' ,,�...a „„� a.tx� � .;.8 -%' 1Post°This.Card SoT;hat it` s V�sible•:From;the Street A roved_PlansMust�be�Reta�ned'gnJob and thls,Gard Must beKe' t, f M Posted Until°Final inspection Has Been Made ,: � �v 3���, �. � �. � Permit R Where aCertaficate;of Occu ant <is=Re aired •suchvB'uldinsF�aII NotbegOccu ied untila:F.mal:;lns ecton hasfi<been made .-...«_>�. . ��.,.._3, ..r,..,r� ;,u�; T.;vp�.�. yam. �q_Y.�,��.�' �= _ ,� .�,�.:�g.s ,�� =.,h,1 ,.,. .�. . <.p �y,�_. z�,.a:����.,r„�p�... .:�,. .. •.�� �. .. �z,c � ..� �" .. Permit No. B-19-2124 Applicant Name: LEWIS&WELDON CUSTOM CABINETRY LLC. Approvals Date Issued: 06/28/2019 Current Use: Structure Permit Type: Building-Addition/Alteration-Residential Expiration Date: 12/28/2019 Foundation: Location: 42 OAKMONT ROAD, BARNSTABLE Map/Lot 349-053 Zoning District: RF-1 Sheathing: Owner on Record: ZAZZERA,STEVEN&SACRAMENTO, Contractor Name:., Clarence W Hart,JR Framing: 1 Address: 42 OAKMONT ROAD s r Contractor:License CS 097094 2 in A1'1 CUMMAQUID, MA 02637 Est Project Chimney: J ct Cost: $50,000.00 Description: replace window-remove soffit and mist dry all on outside wall- Permit Fee: $305.00 new kitchen cabinetry and tile floor Insulation: Insulation: 1 Fee Pald $305.00 Project Review Req: EXISTING KITCHEN REMODEL.WINDOW12KE FOR LIKE Date , 6/28/2019 Final: REPLACEMENT. 4 Plumbing/Gas ' Rough Plumbing: Building Official Final Plumbing: This permit shall be deemed abandoned and invalid unless the work aw'thorjized by this permit is commenced within six months after issuance. All work authorized by this permit shall conform to the approved appl cation and tFie approved construction documents for w"kh this permit has been granted. Rough Gas: All construction,alterations and changes of use of any building and structures shall be in compliance with the local zoning by laws and codes. This permit shall be displayed in a location clearly visible from access street or r3o4d and shall be maintained open for public inspection for the entire duration of the Final Gas: work until the completion of the same. 7 R ' Electrical The Certificate of Occupancy will not be issued until all applicable signatures by the Building and Fire Officals are providedon th s permit. Minimum of Five Call Inspections Required for All Construction Work: x Service: 1.Foundation or Footing Rough: 2.Sheathing Inspection ` 3.All Fireplaces must be inspected at the throat level before firest flue lining is installed Final: 4.Wiring&Plumbing Inspections to be completed prior to Frame Inspection 5.Prior to Covering Structural Members(Frame Inspection) Low Voltage Rough: 6.Insulation 7.Final Inspection before Occupancy Low Voltage Final: Where applicable,separate permits are required for Electrical,Plumbing,and Mechanical Installations. Health Work shall not proceed until the Inspector has approved the various stages of construction. Final: "Persons contracting with unregistered contractors do not have access to the guaranty fund" (as set forth in MGL c.142A). Fire Department Building plans are to be available on site All Permit Cards are the property of the APPLICANT-ISSUED RECIPIENT Final: LEwis &WELDON CUS om BUILDERS DESIGN + BUILD ill Airport Road Hyannis,Massachusetts o26oi 5o8-778 5757 office 508-7785ili fax wliww.lewisandweldon.com PROPERTY OWNER AUTHORIZATION Steve and Rosenildo Sacramento-Zazzera 42 Oakmont Road Cummaquid,Massachusetts 02630 As owner/owners of the subject property hereby authorize Lewis and Weldon to act on my/our behalf, in all matters relative to work authorized by this building permit application and all subsequent sub permits governed by the Electrical Code, as well as Plumbing code G /nr. �z . L _ gig iature of Owner/Owners Date tp f C- i')i LJ�� t'i - 5 YI-6ug—ZR-12 T-r 2 Print Name/Names tom-' is w� ��J wis& Weldon Authorized Representative Lc- Date Print Name VS G Application Number.... ..1...�..r�....... .1. .... ........... MASS. Permit Fee........ 1.2. ............Other Fee,....................... i639• ��� TotalFee Paid............................................................... ...... TOWN OF BARNSTABLE Permit Approval by... ............................. on....!�..���.g....... BUILDING PERMIT map............ .9.5............Parcel........ .�............................ APPLICATION Section 1 — Owner's Information and Project Location Project Address 2— Village Dim 10 14 1-3 Owners Name 1 LD6 54e�P V77) Owners Legal Address '/2— c/)400 i1/%— City COMOA& ,, State I/ Zip 0 Z (D Owners Cell# 36 E-mail 2Z ` -e-( Section 2 — Use of Structure Use Group ❑ Commercial Structure over 35,000 cu�c feet ❑ O Commercial Structure under 35,000 cu .Eet ❑ Single/Two Family Dwelling Section 3 — Type of Permit ❑ New Construction ❑ Move/Relocate ❑ Accessory Structure ❑ Change of use �F ❑ Demo/(entire structure) ❑ Finish Basement ❑ Family/Amnesty ❑ Fire Alarm Rebuild ❑ Deck Apartment ❑ Sprinkler System ❑ Addition ❑ Retaining wall ❑ . Solar ❑ Renovation ❑ Pool ❑ Insulation Other— 1�.1 Spec P �' Section 4 - Work Description i .�.� Ov�z VIE � —Uf-f-- CT W L S 0 d Last undated: 11/15/2018 Application Number........... Section 5—Detail j 3 Cost of Proposed Construction Square Footage of Project Age of Structure Dig Safe Number # Of Bedrooms Existing Total#Of Bedrooms (proposed) l 10 MPH Wind Zone Compliance Method ❑ MA Checklist ❑ WFCM Checklist ❑ Design Section 6—Project Specifics �- rW 9 ❑ Oil Tank Storage ❑ Smoke Detectors _JZ--Plumbing ❑ Gas ❑ Fire Suppression ❑ Heating System ❑ Masonry Chimney ❑ Add/relocate bedroom . r . i Water Supply ❑ Public ❑ Private. Sewage Disposal ❑ Municipal ❑ On Site Historic District ❑ Hyannis Historic District ❑ Old Kings Highway Debris Disposal Facility: I am using a crane ❑ Yes ❑ No Section 7—Flood Zone Flood Zone Designation Within or adjacent to a wetland, coastal bank? Yes ❑ No ❑ Section 8—Zoning Information Zoning District Proposed Use Lot Area Sq. Ft. Total Frontage Percentage of Lot Coverage #of Dwelling Units (on site) Setbacks Front Yard Required Proposed Rear Yard Required Proposed Side Yard Required Proposed '. Has this property had relief from the Zoning Board in the past? ❑ Yes ❑ No Last updated: 11/15/2018 Application Number........................................... Section 9= Construction Supervisor Name �i �V'ti - (� Telephone Number Address �ity Mate ip 6-2 be License NumberC-S 01-+ License Type Expiration Date �� 1 Contractors Email C '15� Cell # 5_D8 3(o V` I understand my responsibilities under the rules and regulations for Licensed Construction Supervisor in accordance with 780 CMR the Massachusetts State B "Iding Code. I understand the construction inspection procedures,spec' c inspections and documentatio req ' ed by 80 MR and the Town of Barnstable.Attach a copy of your license. Signature Date Section 10—Home Improvement Contractor Name vv i S 0,72NCwF4r) �e e on&- umber Address (� ►t� ��4—� City � G� tate ip C�Z�j C� r Registration Number � Expiration Date �- I understand my re o ' ' 'es under the rules and regulations for Home Improvement Contractors in accor ce with 780 CMR the Massac usetts Sta BA ' Code. I understand the construction inspection procedures,specific ' pectin and documentation re uired by 7 0 C d the Town of Barnstable.Attach a copy of your H.I.C... �q C9Signature Aj Date Section 11 —Home Owners License Exemption Home Owners Name: p; Telephone Number Cell or Work Number I understand my responsibilities under the rules.and regulations-for Licensed Construction Supervisor in accordance with 780 k CMR the Massachusetts State Building Code. I understand the construction inspection procedures,specific inspections and documentation required by 780 CMR and the Town of Barnstable. Signature 4 Date P LICANT SIGNATURE Signature Date U is / c Print Name Telephone Number Soo C E-mail permit to: �`�Z� S1y - , Last updated: 11/15/2018 Section 12 —Department Sign-Offs Health Department ❑ Zoning Board(if required) Historic District ❑ Site Plan Review(if required) ❑ Fire Department ❑ Conservation ❑ For commercial work,please take your plans directly to the fire department for approval Section 13 — Owner's Authorization as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application for: (Address of job) Signature of Owner date y Print Name , i i a Last updated: 11/15/2018 ofTME,, TOWN OF BARNSTABLE Permit No. ....199h99..... . BUILDING DEPARTMENT TOWN OFFICE BUILDING Cash .......... l °�nriv HYANNIS,MASS.02601 Bond CERTIFICATE OF USE AND OCCUPANCY Issued to David A. & Cynthia Parrella Address lot #198 42 Oakmont Road, .Cummaquid USE GROUP FIRE GRADING OCCUPANCY LOAD THIS PERMIT WILL NOT BE VALID, AND THE BUILDING SHALL NOT,BE OCCUPIED UNTIL SIGNED BY THE BUILDING INSPECTOR UPON SATISFACTORY COMPLIANCE WITH TOWN REQUIREMENTS AND IN ACCORDANCE WITH SECTION 119.0 OF THE'MASSACHUSETTS STATE BUILDING CODE. l i Nove-tuber 13 19...86 afi ............................ .............. ! ......�...,�.... Building Inspector .lot.. . e2 LOT 193 LOT' 197 P8. 235 PC 4s z LOT 198 tv 42,780 * S.F LOT 192 v° �89 3g 0 �Q o �� h LOT 199 CERTIFY THAT THE FOUNDATION I CERTIFY THAT THE FOUNDATION ; .3 IS L@SATED ON THE LOT AS : IS LOCATED IN FLOOD. PLAIN SHOWN. AND THAT ITS LOCATION ZONE. C . AS SHOWN ON CONFORMS WITH THE ZONING BY- -� a FLOOD INSURANCE RATE MAP LAWS OF THE TOWN OF BARN - COMMUNITY PANEL NO 250001 0010 B STABLE. AND THAT FLOOD PLAIN ZONE C IS NOTA SPECIAL FLOOD HAZARD AREA. DATE. .73. Reg istereff Professional Land Surveyor Regis red Professional Land Surveyor PLOT PLAN holmes and mcgrat h, inc. °f PREPARED FOR civil engineers and Iand surveyors MARY sN ELLEN DAV I D PARRELL A 200 main street s 1TREETER �. N No. 29291 CUMMIQUID BARNSTABLE, MASS. falmouth,ma. 02540 Scale '. I"= 50' Da•te. JUI_Y 22, 1986 i Drawn: MJB Checked: M66 JOB N° 86197 DWG N`A 1597 4 LAW OFFICES OF PHILIP M. BOUDREAU 390 NORTH STREET HYANNIS, MASSAGHUSETTS 02601 (617) 775-1085 PHILIP M. BOUDREAU June 18, 1986 PHILIP MICHAEL BOUDREAU MARK H. BOUDREAU Mr. Joseph Daluz Building Inspector Town of Barnstable Town Hall Hyannis, MA 02601 RE: Lot 198, Oalawnt Road, Omlmaquid, MA Dear Mr. Daluz: I have examined the title of the above-referenced lot as well as of the premises abutting said lot as per the request of David A. Parrella and Cynthia H. Parrella. I find that lot 198 has been held in separate ownership since August 24, 1981. 'Under Massachusetts General Laws Chapter 40A Section 6, the lot is given five years protection fran the date of a zoning change or five years after January 1, 1976, which ever is later. The protection runs only to lots for single or two family residential use, such as is proposed here. I enclose a copy of the zoning change effective November 4, 1977. I hope that this information is helpful. Sincerely, Mark H. Boudreau Assessor's office (1st floor): ��5 SEPTIC SYSTEM ML157' BE Assessors map 'and lot number 349...... �.� ........ L_INSTALLED IN CCMPLIAW; Prof THE Toy♦ Board of Health (3rd floor): a 6 _ � , WITH TITLE 5 Sewage Permit number .....................................'.............�.:. NVIRONMENTAL CODE AV t 33AUSTIBLE, Engineering Department (3rd floor): �,,�JATION- House number dui oypYa� APPLICATIONS PROCESSED 8:30-9:30 A.M. and' 1:00-2:00 P.M. only TOWN. .OF BARNSTABLE r BUILDING- INSPECTOR y . APPLICATION FOR PERMIT TO ... m?,S-rALP....4v`fue....F,4wl4l............4e4"/1d�'...................... TYPE OF CONSTRUCTION ...........t ".® ....... ................................................................................. L..'/.. ..v�.7..................... a TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: Location la..'1/.9..8....... .....�G!!4peelm,�f 1/d17. '...................................................... f..................... Proposed Use ... /dTl''YC- s//11GL /C. .......... .............�...........y. ................................ .019... Pst Zoning District J /................................Fire District .............. .................................... ............... ... .. ........:..... .. Name of Owner �/ !� �� r �Yy R � v�v �.4�/(� � �& /A/i4�(/,!1/9S /w e -..... .....�..... ....................................Address ....-.. .......--............................................ ...... ..,..... n Name of Builder �4(�d /`/ � �`"�� ..............Address ( ��'� /lf 'G`� �� .../�/��N/S Name of Architect -�gi .. o�...... Address i .. ✓ /`�! 'Number of Rooms .................9...........................................Foundation �i �`J.. � ... Exterior ... ..��y! ✓!�5............................Roofing A&OA.1.�� i Floors ?... /Q.r�/�//� / ✓>°►L pGt �i// ..............................................Interior .. .�..�{�... ........":x!.........4� .................................... rieatingr.[�4 .Gi* ....... Plumbing ...©l..a.. -� �7!..................................................... ........................................ Fireplace �i ���j�� .-= 2J��.S r.............................Approximate Cost ......... �/.J'....�® ......... Definitive Plan Approved by Planning Board __/ Cd ---________19`�`_ . Area ..... ...................... Diagram of Lot and Building with Dimensions :/ Fee . ..�................... " ow CSA SUBJECT TO APPROVAL OF BOARD OF HEALTHH 00 PIiNC11��1 { lF- _ ItAS AM w gat 160.�0 OAKM ONT ROA1� (50` -%Vj-r IVA f OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regardi g the above construction. Name .. ,f.......... ...................................... Construction Supervisor's License . a3. 3 r�PARIRELLA, DAVID & CYNTHIA .r N0 29699 permit for ••,Build r 2 Story; ...... 6 ... �... 'I Sin.le Family Dwelling ........................................... , Location ...Lot. ...#198. .,.....42. ...Oakmont Road.... .... . ...... . . .. . ........... ........ .................. .. �5 r .��•... %� '� . mot) rr .t ,F '2 3 David' & C nthia Parrella. Owner .X.......................... t . Type of Construction ..:Frame • ,, r. '�• _� Plot ..... .... ......... Lot .... . Ile- 13 Wit... r � _. Permit Granted .. July 25:...... ....19 86 ' �'' i T Date of:Inspection � .........'....19 s Date Co leted ....................•���...�� ..4 9 � e=� y � •'# .� ,.d i� r__ . p .... lo - _ Lewis and Weldon Custom Kitchens Steve Zazzera & Rosie Sacramento 111 Airport Road 42 Oakmont Road Hyannis, MA 02601 Cummaquid, MA 508-778-5757 508-367-9889 www.lewisandweldon.com 6/28/2019 stevezazz@gmail.com Kitchen Not To scale #1 255 63 24 17 3/16-3/4 - _ 3/4 17 3/16-3/4 1/2 36 11/2 1 24 I � t 6 2015/16 t O 24 815/13/ Cranberry Cove 6 11/z 1 1/2 Perimeter Cabinetry:Maple Painted Frosty —1 ! Island Cabinetry:Maple Painted Marina Maple Dovetail Drawer/Full Ext&Soft Close 3/4"thick doors 24 3/16 2.3125"Stiles&Rails Outside Edge:L-149 Inside Edge:Bevel Panel:Reverse G-Cove 1515/16 Top Drawers:Flat Slab Glass Doors: 1-Lite w/wood shelves&glass inserts(clear glass) 3/4 45 Crown:2.25"Cove to ceiling Light Rail:Bevel(to match door inside edge) Island Legs:Like front display,but square blocks #7 1181/8 Pucks in glass cabinets&under cabinet lighting on perimeter 42 1 #2 3/4 9 29 1/4 30 29 1/4 9 s/a 158 55 3/4 3/4 3/4 12 #6 #5 32J y�q 32 24 3/16 I s 1061/2 � 15 15116 � Zo Barnstable Bldg.Dept. 13)�1 --_- 3 4 - Approved by: Permit #3 30 Lewis and Weldon Custom Kitchens Steve Zazzera & Rosie Sacramento 111 Airport Road 42 Oakmont Road Hyannis, MA 02601 Cummaquid, MA 508-778-5757 508-367-9889 www.lewisandweldon.com 6/28/2019 stevezazz@gmail.com Kitchen - Wall i Not To Scale 1 1/2 1 1/2 —12 5/8 4 ♦, _ 24 ,. ...,. 173/16 fi3...., 173/16 . ._.. _... 36 162.625"to trim . f ♦\♦ / 3 puck puck i� 60 33 3/8 \ 33 3/8 / 33 3/8 f ♦ l' 73.4375" to .,�., 737/16 window ctr. \\ 79 3/a //f 87 3/8 ♦ ��` i "Oversize mid rail \\ for light switches" ON/ 1 7/8 24-- 0 1 Isink to be like Granata 0 34 1/2 ` Super Susan 00_� 3a 1/z 36"Thermador 3a 1/2 ,- Paneled Fridge " za T361T90ONP %f �.,\. Tray \ , Double Trash - -- RC3018WH Pull-Out 30"Rohl Farm Sink Thermador - f` 36 2015/16 'NEED SINK" Paneled D/W —..-815/16-• 36 11/2 11/2 DWHD650WPR 111/2 11/2 —12 5/8 c» Lewis and Weldon Custom Kitchens Steve Zazzera & Rosie Sacramento 111 Airport Road 42 Oakmont Road Hyannis, MA 02601 Cummaquid, MA 508-778-5757 508-367-9889 www.lewisandweldon.com 6/28/2019 stevezazz@gmail.com Kitchen - Wall 4 Not To Scale confirm outlet locations 1 1/4 o Insert"ID" o Q 30"Thermador Speed Oven 0 0 MC30WS 0 DD 5/16 pad 28.5x22. u ider o e 34 1/2 (2) ROT's o t ILL:= 9 29 1/4 30 29 1/4 9 3/4 3/4 1/3i(-5 17/3:1/2 —(-5 1/2j/2 120 L Lewis and Weldon Custom Kitchens Steve Zazzera & Rosie Sacramento 111 Airport Road 42 Oakmont Road Hyannis, MA 02601 Cummaquid, MA 508-778-5757 508-367-9889 www.lewisandweldon.com 6/28/2019 stevezazz@gmail.com Kitchen - Back of Wall 4 Not To scale 1 1/4 3 1/2 34 1/2 29 1/2 .'29 1/2 .'29 1/2 29 1/2 'JI 5:� 17 5/8 106 1/2 17 5/8 3/4 »-(-5 1/2:(-3/4) (-1/0(-5 15/3:1/2 120 Lewis and Weldon Custom Kitchens Steve Zazzera & Rosie Sacramento 111 Airport Road 42 Oakmont Road Hyannis, MA 02601 Cummaquid, MA 508-778-5757 508-367-9889 www.lewisandweldon.com 6/28/2019 stevezazz@gmail.com Kitchen - Wall 5 Not To Scale 1 1/4 34 1/2 30 1/2 3/4 3/4 +5 1/16) (-36 15/16) (-11(-4 15/16) 32 Lewis and Weldon Custom Kitchens Steve Zazzera & Rosie Sacramento 111 Airport Road 42 Oakmont Road Hyannis, MA 02601 Cummaquid, MA 508-778-5757 508-367-9889 www.lewisandweldon.com 6/28/2019 stevezazz@gmail.com Kitchen - Wall 7 Not To Scale ..�. r243/16 - - _.. 42 243/16 s 13 1/4 Thermado IX \+. Vr Insert TN630W / 33 3/8 \ 3/4 33 3/8fi* 4 �/ swg ,,. 87 3/8 `' I j. o` \\ 30 x\ \`\' `\ %iz O 1 O O O O O 24 '♦%♦// \ FM, `\ o 341/2 Spice Pull-Out 34 1/z i 34 1/2 36 3/4 36"Thermador Range PRD366WHU j'' /;/ , f 15 15/16 12 36 15 15/16 36 1 1,314 118 1/8