Loading...
HomeMy WebLinkAbout0112 SCUDDER'S LANE rra c . aerie • Permitting History, 112 Scudder Lane; Moran//Miller, Barnstable Village Date submitted Application Approved Applicant Moran and Builder Phil Miller submitted a report from Informal discussion an engineer stating that the building foundation was in a poor 10/10/07 condition and would not support a second floor. Moran stated that he would like to demolish the building. Board indicated that the main house structure should be retained. Informal discussion Informal review of plans. Moran stated that they would retain 2 10/24/07 main portions of house. All discussed portions of house to be removed. 11/07/07 Approved plans showing oldest portions of structure to be maintained, 11/28/07 11/28/07 Thomas Moran signed Cert. of Understanding 12/07/2007 Plans approved dated 11/6/07 11/27/08 Ltr 1/31/08 Letter in file from Hayden Building Movers to T. Moran to secure and move a 24 X 24 ft portion of the house. Chimney would be removed. Most of building demolished Building Inspector LeBoeuf stated that the two main historic portions of the house could have been retained OKH Approved (Modification) Certificate of Demolition after the 2/21/08 building was substantially demolished. Applicant's attorney states that they want to put it back the way it was originally 3/26/08 approved. Board approved subject to top of foundation at 40.88, antique brick for chimneys, and brick veneer for foundation. Plans submitted 3/26/08 with application submitted 2/21/08 Owner Moran signed Statement of Understanding (not dated) 10/23/08 Approved removal of a portion of existing garage and replacement with new structure 12/10/2008 with application submittedl0/23/08 Owner Moran signed Statement of Understanding (not dated). Ltr from Building Inspector stating that frame inspection shows changes between plans approved by OKH and project as built. Letter 12/1/08 "...proceeding at your own risk". re conversation 11/24/08 Construction has continued submitted 12/3/08 Application for"window changes and modification of rear roof". time ext to 2/28/09 Trim is Azek. r , . �� Town of Barnstable R,,,..., c � T 200 Main Street, Hyannis MA 02601 508-862-4038 Application for Building Permit Application No: TB-17-3152 Date Recieved: 9/13/2017 Job Location: 112 SCUDDER'S LANE,BARNSTABLE • Permit For: Building-Siding/Windows/Roof/Doors Contractor's Name: State Lic. No: Address: , , Applicant Phone: (508) 778-4911, —a . 2 t „--,, (Home)Owner's Name: DONOHUE,ELISABETH B TR Phone: (508)771 449,8 `� ril P (Home)Owner's Address: 112 SCUDDER'S LANE, BARNSTABLE,MA 02630. 0 -- m ; co Work Description: Replace(7)windows and two doors 1 a %. Total Value Of Work To Be Performed: $15,000.00 Structure Size: 0.00 0.00 0.00 Width Depth Total Area I hereby swear and attest that I will require proof of workers'compensation insurance for every contractor,subcontractor,or other worker before he/she engages in work on the above property in accordance with the Workers' Compensation Act(Chapter 568). I understand that pursuant to 31-275 C.G.S.,officers of a corporation and partners in a partnership may elect to be excluded from coverage by filing a waiver with the appropriate District Office;and that a sole proprietor of a business is not required to have coverage unless he files his intent to accept coverage. I hereby certify that I am the owner of the property which is the subject of this application or the authorized agent of the property owner and have been authorized to make this application. I understand that when a permit is issued,it is a permit to proceed and grants no right to violate the Massachusetts State Building Code or any other code,ordinance or statute,regardless of what might be shown or omitted on the submitted plans and specifications. All information contained within is true and accurate to the best of my knowledge and belief. All permits approved are subject to inspections performed by a representative of this office. Requests for inspections must be made at least 24 hours in advance. Signed: EJ Jaxtimer 9/13/2017 (508)778-4911 Applicant Date Telephone No. Estimated Construction Costs/Permit Fees Total Project Cost: $15,000.00 Date Paid Amount Paid Check#or CC# Pay Type Total Permit Fee: $76.50 Total Permit Fee Paid: $0.00 r �'' � 4ha�ka:X f r 7,,�xk s3 I n; i Ary ,laHIS I QT P ®t. IT ,j 01(fl'‘. 17,N, Town of Barnstable Building Post This Card So That rt is VisiblefFrom'th i:t-ieet-'Approved::Plans Must be'Retained d Jgb and this Card Mus#.be:Kept enxxs[ees • „ t ,0 % M^sa. Posted Until Emai Ms ection Has Been Mader = :� ° � ets � Where a"Certificate of Occupancy i ,Requireellsuch Biiiidmg shall Not be Occupied until a Final InspectionTfiasibeen made , Permit mit tea,>.:ea,.,..h,„,x,«ke ••-• r?• ,...'„.> ,._. ,..,,,,, r .=...x. ,z,. � .may:. +a ,« .-..- ., .,c.,-,r.. . .�..,,- .� .... .,4«S,� dkz._... ., asx _ ;,� . '4-a",— ,44, Permit No. B-17-3234 Applicant Name: E J JAXTIMER, BUILDER, INC. Approvals Date Issued: 12/22/2017 Current Use: Structure r Permit Type: Building-Alteration INTERIOR Work Only- Expiration Date: 06/22/2018 Foundation: - Residential Map/Lot: 259-013 Zoning District: R-2C Sheathing: .,�� ' Location: 112 SCUDDER'S LANE, BARNSTABLE k CG.r V �zx Contractor Name'" E J JAXTIMER, BUILDER, INC. Framing: 10/ 2y �epwAk eic— Owner on Record: DONOHUE,ELISABETH B TR , Contractor License' 110609 2 �'b ''-vy ',, Address: 112 SCUDDER'S LANE } "" x x Est. Protect Cost: $75,000.00 Chimney: BARNSTABLE, MA 02630 i ,./ PerrIit Fee: $432.50 0VIz i8 E8 X ,4 Insulation•Ok Q f(�C,iRec�•_ Description: FINISH PORTIONS OF EXISTING GARAGE AND 11N0 CONNECTED _ '��. Fee Paid = $432.50 OUT BUILDINGS;TO INCLUDE GAME ROOM OVER ' " `'' Date „ 12/22/2017 Final: GARAGE,BATHROOM,SITTING AREA AND GYM AT ATTACHED AT BUILDINGS.ALL WORK IS NON-STRUCTRUAL AND INTERIOR ALL SAME STRUCTURE. -- � Plumbing/Gas Rough Plumbing: Project Review Req: maintain fire separation r x11. Building Official [ ,, .",,,, '‘,:'%''•.; -. Final Plumbing: This permit shall be deemed abandoned and invalid unless the work authorized by this permit is commenced within siz"months afterssuance. Rough Gas: All work authorized by this permit shall conform to the approved application nd the approved construction documents for which this permit has been granted. ' Final Gas: All construction,alterations and changes of use of any building and structuresshall .be in compliance with the local zoning by laws.and codes. - This permit shall be displayed in a location clearly visible from access street orYoad and shall be maintained open for public inspection for the entire duration of the work until the completion of the same. X r 5 Electrical •The Certificate of Occupancy will not be issued until all applicable signaturesy the Building and Fire Officials are provided on this£permit. Service: • Minimum of Five Call Inspections Required for All Construction Work Itt k 1.Foundation or Footing ., Rough: 2.Sheathing Inspection Final: 3.All Fireplaces must be inspected at the throat level before firest flue lining is installed 4.Wiring&Plumbing Inspections to be completed prior to Frame Inspection Low Voltage Rough: 5.Prior to Covering Structural Members(Frame Inspection) 6.Insulation 7.Final Inspection before Occupancy Low Voltage Final: _ Health Where applicable,separate permits are required for Electrical,Plumbing,and Mechanical Installations. Work shall not proceed until the Inspector has approved the various stages of construction. Final: "Persons contracting with unregistered contractors do not have access to the guaranty fund" (as set forth in MGL c.142A). Fire Department Building plans are to be available on site Final: All Permit Cards are the property of the APPLICANT-ISSUED RECIPIENT TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION • Map -L59 Parcel t.3 Application # -( -373 Health Division �U, Date Issued / 2-/2 c/7/2 _�-,ivy U _ r"� Conservation Division ��� Application Fee (137 Sw EC1 . Planning Dept. T 2 2Q11 Permit Fee • Date Definitive Plan Approved by Planning Board OW�r Cr Historic - OKH Preservation/ Hyannis Project Street Address t,2 5 c vA-es L e Village 13arv►s4cS,k Owner Eli 54)All .3 De:v.61oc Address (I Z 50v)�cr5 L c/ 130.rrrrizgc, Telephone Permit RequestRh;st, porAioAs csc C.Ct 4q Trey 44. -Ic , KonneeW 0300;4i/1s; -h ;Acta& qw,,c roc," cuer 9r-a,yt,h4K. .4411 etre.- ` 5y� Adi- emu,Ik,� < All ;s —J`�rvG+ CAse4 i otri Or. All _ er lIrt. Square feet: 1st floor: existing 311 proposed - 2nd floor: existing 560 proposed - Total new - Zoning District R-26 Flood Plain - Groundwater Overlay - Project Valuation 75,oO0 Construction Type ck.31-r 5 Lot Size 1.7S acres Grandfathered: ❑Yes ❑ No If yes, attach supporting documentation. Dwelling Type: Single Family 41 Two Family J Multi-Family (# units) i i-tcr wsr1< Age of Existing Structure Historic House: ❑Yes ❑ No On Old King's Highway: Yes ❑ No Basement Type: ❑ Full ❑ Crawl ❑Walkout a Other SU Basement Finished Area (sq.ft.) - Basement Unfinished Area(sq.ft) Number of Baths: Full: existing - new I Half: existing - new Number of Bedrooms: - existing _new Total Room Count (not including baths): existing - new 3 First Floor Room Count Z Heat Type and Fuel: Gas ❑ Oil ❑ Electric ❑ Other Central Air: J4 Yes ❑ No Fireplaces: Existing New Existing wood/coal stove: ❑Yes ❑ No Detached garage: a existing ❑ new size_Pool: ❑existing ❑ new size _ Barn: ❑ existing ❑ new size_ Attached garage: ❑existing ❑ new size _Shed:.4 existing ❑ new size Other: Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑Yes ❑ No If yes, site plan review# Current Use 5'ir51. cc%J, "' Proposed Use 5‘•�L C44 APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Name Telephone Number (--0 ! l - ` 11 18 Address 9 Fos.. c License # S 00325 avv i5, MA Home Improvement Contractor# OCa I Email c�- -ey ag Jc 4; 1"+er. fir^ Worker's Compensation # 0105 ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO Approve, 'f -foe)),fy- SIGNATURE �, DATE FOR OFFICIAL USE ONLY APPLICATION # DATE ISSUED MAP/ PARCEL NO. 4 ADDRESS VILLAGE OWNER DATE OF INSPECTION: FOUNDATION FRAME INSULATION • -FIREPLACE - ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH FINAL 'GAS: ROUGH FINAL • FINAL BUILDING : DATE°CLOSED OUT ASSOCIATION PLAN NO. i / t REScheek Software Version 4.6.3 /000 N. Compliance Certificate • Project Renovation Work Energy Code: 2015 IECC Location: Barnstable, Massachusetts Construction Type: Single-family Project Type: Alteration Climate Zone: 5 (6137 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 112 Scudder Elizebeth B. Donohue EJ.Jaxtimer Barnstable, MA 02630 112 Scudder Ej.Jaxtimer Custom Builder Barnstable, MA 02630 48 Rosary Lane Hyannis, MA 02601 '; t- « -+c:a.s -s-.+a., zn..�e ..--- aP�'-z r. x w �t�t. , , 'f" .n.. .. ' Compliance Passes using prescriptive requirements foralterat_ion projects'7'._ �k .`= 4 f 4 �,` ` . Envelope Assemblies _ :g:° ,i h 4ilia�5* .WAV''tl4,i z'�irOSS Are dam` f tt;'-. ,.:„ g-t tk:it ii'� nh"T,At F' $` 3 ?E sys rn.�. z`'S#$ s';:k " . 44,m- �..,.7. Cavity x^4 Cont :, -- .,U I x. ,; p x '.- y1-s'a ��r;m11.�y : *fit-f^; -,� Rui z or R Value R Value U Factor' UA % ,x�:.�,s,� .�-P,a� .. s ,� , ,� `Penmeter t ', �� Ceiling 1:Cathedral Ceiling 1,820 40.0 0.0 0.026 47 Wall 1:Wood Frame, 16"o.c. 920 21.0 0.0 0.057 41 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 166 0.290 48 Door 1:Glass 40 0.300 12 Wall 2:Wood Frame, 16"o.c. 450 24.0 0.0 0.054 24 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space --- --_ --- Exemption: Framing cavity filled with insulation Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Keith Presswood VP kelth -essw o'( 08-01-2017 Name-Title Signature Date Project Notes: REScheck by Cape Cod Insulation, Inc. 18 Reardon Circle South Yarmouth, Ma. 02664 800-696-6611 # 700206 Project Title: Renovation Work Report date: 08/01/17 Data filename: Untitled.rck Page 1 of 9 • • REScheck Software Version 4.6.3 Onspect on Checkilist Energy Code: 2015 IECC Requirements: 39.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. eetiaxi �' - Plans Verified Fi&d verified `m I i i ... - n # Pre InSpecttonfPlan�Rgu�e� � �(alue��� -rfaiute' � � �v p ea?�,�� �Gst�m�nt�/.�l�su?�RtlopS .:• -n. �.4..t1 ...D.._ ul4 x.. 3-_ 3�`f"' 103.1, Construction drawings and 4.�$E0� ,� Vd r❑Complies Requirement will be met. 103.2 .documentation demonstrate xs T s , [PR1]1 energy code compliance for the ❑Does Not building envelope.Thermal ,= = � p .' ":❑Not Observable " �„litstwe-_`,, ❑NotA Applicable envelope represented on ��' >-- �� �- � pp construction documents. r.Atrzot ? ?" 103.1, Construction drawings and V V {r N` -3 '`❑Complies 103.2, :documentation demonstrate ❑Does Not 403.7 energy code compliance for ` „ < x ' [PR3]1 lighting; and mechanical systems. S V =❑Not Observable .Systems serving multiple . '' .y ❑Not Applicable dwelling units must demonstrate compliance with the IECC - a a ` Commercial Provisions. gagrate4111.`sue M tf 3A2.1; :Heating and cooling equipment is: Heating: Heating: ;❑Complies 443,7 ' sized per ACCA Manual S based ; Btu/hr Btu/hr ;❑Does Not ig 2a on loads calculated per ACCA Cooling: Cooling: ZNot Observable Manual J or other methods ; Btu/hr Btu/hr -040. approved by the code official. Not Applicable :EakViSsWil; Additional Comments/Assumptions: ri IHigh Impact(Tier 1) RIMedium Impact(Tier 2) ) 3 Low Impact(Tier 3) 1 Project Title: Renovation Work Report date: 08/01/17 Data filename: Untitled.rck Page 2 of 9 r �� „ .:.Foundation Icispectlon �' - ' Compbes'a ... w Con�t�lertt$/Assuan tib�15' - '" r� �. 3;Q3 1 :A protective covering is installed to :❑Complies Exception: Requirement is not applicable. { it protect exposed exterior insulation ;❑Does Not and extends a minimum of 6 in. below grade. ❑Not Observable Mgan:04! ❑Not Applicable 40A,9 -:Snow-and ice-melting system controls'❑Complies 1FOIZfz, ,:installed. .❑Does Not j❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 Hi h Impact(Tier 1) n j Medium I 9 P �2�., Impact(Tier 2) � ,,;Low Impact(Tier 3) Project Title: Renovation Work Report date: 08/01/17 Data filename: Untitled.rck Page 3 of 9