Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0097 OUTPOST LANE - HAZMAT
97 6ce�a s�— (�rum �y�-,}Px v�� II� � __ INE Town of Barnstable B"KSTABL& Regulatory Services Department Public Health Division 2007 200 Main Street, Hyannis MA 02601 Office:508-862-4644 Thomas F.Geiler,Director Fax:508-790-6304 Thomas A.McKean,CHO To: Date: April 1, 2009 John F. Remmers 97 Outpost Lane Centerville, MA 02632 RE: Underground Storage Tank at: PW 97 Outpost Lane Centerville,MA Map Parcel: 172094 Tank NO: 1 Tag NO: 000242 Our records indicate that your underground fuel (or chemical) storage tank is over 30 years old, and has not been removed as required by section 326-3: subsection 2 of the Town of Barnstable Code regarding fuel and chemical storage systems. You are directed to remove this tank within sixty(60) days from the date of this notice. After your tank is removed,please furnish this office evidence in the form of a permit from your local Fire Department within ninety(90) days of the receipt of this notice. You may request a hearing provided a written petition requesting same is received by the Board of Health within ten (10) days after this order is served. Per Order of the Board of Health Thomas A. McKean, RS, CHO Health Agent �OFTHE 1p� Town of Barnstable ti Regulatory Services Barnstable 9s MAASSSsLs, - Richard V. Scali, Director mericaCity E1639. Public Health Division 11111 Thomas McKean, Director 2007 200 Main Street Hyannis, MA 02601 Office: 508-862-4644 Fax: 508-790-6304 July 2, 2015 REMMERS, JOHN F &JEANNE 97 OUTPOST LN CENTERVILLE,MA 02632 RE: Underground Storage Tank 97 OUTPOST LANE Centerville Map/Parcel: 172094 Tank Number: 1 Tag Number: 00242 FINAL NOTICE Board of Health records indicate that an underground fuel(or chemical) storage tank at the above location exceeds thirty(30)years in age and has not yet been removed as required by the Town of Barnstable Code Chapter 326, Section 3,Fuel and Chemical Storage Tanks. You are directed to remove this tank. Upon completion of the tank removal, please submit to this office a copy of the permit for storage tank removal issued by your local Fire Department. This permit is required to be obtained prior to the tank removal. This copy of the removal permit serves as documentation that the underground storage tank was properly removed and disposed of. Should you be unaware of the existence of the above mentioned tank or its possible previous removal, an independent third party(i.e. oil company,tank removal company, or environmental services company) may be able to assist you in physically locating and/or verifying the current existence of the tank. Should this be the case, a written document from the independent third party is required as verification that the tank had been previously removed and/or does not exist. Failure to comply with this second and FINAL order of the Board of Health will result in automatic scheduling of a hearing before the Board at the next available public meeting,which will be August 18, 2015. The meeting will begin at 3:00 PM and will be located at Barnstable Town Hall, 367 Main Street, Hyannis, MA 02601. NOTE: The July Board of Health meeting date was changed. Therefore,this issue will be addressed at the August 18'1' meeting instead. Thomas A. McKean, RS, CHO Public Health Division,Director Q:\Hazmat\Underground Tanks\2015\letters sent 070215-FINAL NOTICE\30 yr old UST 97 Outpost Lane CENT.doc I. r °FIMEl°� Town of Barnstable ti Regulatory Services Barnstable 9s MAASSSsLs,� Richard V. Scali, Director A"mericaCity 039. p�0 Public Health Division ED MA'S I I Thomas McKean, Director 2007 200 Main Street Hyannis, MA 02601 Office: 508-862-4644 Fax: 508-790-6304 July 2,2015 REMMERS, JOHN F&JEANNE 97 OUTPOST LN CENTERVILLE, MA 02632 RE: Underground Storage Tank 97 OUTPOST LANE Centerville Map/Parcel: 172094 Tank Number: 1 Tag Number: 00242 FINAL NOTICE Board of Health records indicate that an underground fuel(or chemical)storage tank at the above location exceeds thirty(3 0)years in age and has not yet been removed as required by the Town of Barnstable Code Chapter 326, Section 3,Fuel and Chemical Storage Tanks. You are directed to remove this tank. Upon completion of the tank removal, please submit to this office a copy of the pen-nit for storage tank removal issued by your local Fire Department. This permit is required to be obtained prior to:the tank removal. This copy of the removal permit serves as documentation that the underground storage tank was properly removed and disposed of. Should you be unaware of the existence of the above mentioned tank or its possible previous removal, an independent third party(i.e. oil company,tank removal company, or environmental services company) may be able to assist you in physically locating and/or verifying the current existence of the tank. Should this be the case, a written document from the independent third party is required as verification that the tank had been previously removed and/or does not exist. Failure to comply with this second and FINAL order of the Board of Health will result in automatic scheduling of a hearing before the Board at the next available public meeting, which will be August 18, 2015. The meeting will begin at 3:00 PM and will be located at Barnstable Town Hall, 367 Main Street, Hyannis,MA 02601. NOTE: The July Board of Health meeting date was changed. Therefore,this issue will be addressed at the August 18t1i meeting instead. Thomas A. McKean,RS, CHO Public Health Division,Director Q:\Hazmat\Underground Tanks\2015\letters sent 070215-FINAL NOTICE00 yr old UST 97 Outpost Lane CENT.doc ff pFZHE Tory Barnstable P� ti Town of Barnstable �T :NASA. 0` Board of Health w-am�cae;ro nA RN STAnLE, •. �ATf039. 0 MX a,0 200 Main Street, Hyannis MA 02601 m 2007 OFFICE: 508-862-4644 Wayne Miller,M.D. FAX: 508-790-6304 Paul Canniff,D.M.D. Junichi Sawayanagi John & Jeanne Remmers, 97 Outpost Lane, Centerville, MA 02632 ACKNOWLEDGEMENT OF RECEIPT: August 12, 2015 You are to appear before the Board of Oeafthfor a hearing regarding non-compliance of removal of underground storage tankat: 97 Outpost .cane, Centerville„ as per the Public xealth Division letter datedjuly 2, 2015. Thankyou. Your item is scheduled to be heard at the Board of Health Meeting on the: Date of: Tuesday, August 18, 2015 Meeting Location: Town Hall, 367 Main St, Hyannis Hearing Room, Second Floor Time: 3:00—6:00 P.M. Approximately three days prior to meeting, an agenda will be sent out to you— once it is available. It will also be available on line at the town website: www.town.barnstable.ma.us Go to ...`Boards & Committees > Board of Health - or- Go to Official Agendas Any questions, please call Sharon Crocker at 508-862-4739. Thank you. QAAGENDAS BOH\let Receipt of BOH Submission 97 Outpost Ln Cent Aug2015.doc Ft"E T0� Town of Barnstable ti Regulatory Services Barnstable 9 AM.M Richard V. Scali, Director AM4medca City 1619. Public Health Division I I rE0 MA'S� Thomas McKean, Director 2007 200 Main Street Hyannis, MA 02601 Office: 508-862-4644 Fax: 508-790-6304 March 30,2015- REMMERS, JOHN F &JEANNE 97 OUTPOST LN CENTERVILLE, MA 02632 RE: Underground Storage Tank 97 OUTPOST LANE Centerville Map/Parcel: 172094 Tank Number: 1 Tag Number: 00242 Board of Health records indicate that an underground fuel(or chemical)storage tank at the above location exceeds thirty(30)years in age and has not yet been removed as required by the Town of Barnstable Code Chapter 326, Section 3, Fuel and Chemical Storage Tanks. You are directed to remove this tank within sixty(60)days from the date of this Notice. Upon completion of the tank removal and within ninety(90)days of receipt of this Notice, please submit to this office a copy of the permit for storage tank removal issued by your local Fire Department. This permit is required to be obtained prior to the tank removal. This copy of the removal permit serves as e documentation that the underground storage tank was properly removed and disposed of. Should you be unaware of the existence of the above mentioned tank or its possible previous removal, an independent third party(i.e. oil company,tank removal company, or environmental services company) may be able to assist you in physically locating and/or verifying the current existence of the tank. Should this be the case, a written document from the independent third party is required within ninety (90) days of receipt of this notice as verification that the tank had been previously removed and/or does not exist. You may request a hearing before the Board provided that a written petition requesting same is received by the Board of Health within ten(10)days after this order is served. Failure to comply with an order of the Board of Health will result in automatic scheduling of a hearing before the Board at the July 14, 2015 public meeting. The meeting will begin at 3:00 PM and will be located at Barnstable Town Hall, 367 Main Street,Hyannis, MA 02601. Thomas A. McKean,RS, CHO Public Health Division,Director QAHazmat\Underground Tanks\2015\letters\30 yr old UST 97 Outpost Lane CENT.doc r . CENTERVILLE - OSTERVILLE FIRE DEPARTMENT ' PERMIT FOR STORAGE OF FUEL OIL In accordance with provisions of Chapter 148, 0. L., and Regulations made under authority thereof. Name -Burke Burke Homes. ............... Name ...Wm, Davis (owner or occupant) (Installer) i Address 4.7..Qutputi...La.,.....Cent4ddress 1!@XA .Q#A.. Burner Storage Make .Tr1133TY12........................................ Type of Tank ..5t:@E1/aval ........... Manufacturer'MM?le...UPMIP EVAU Capacity .1.000.. gals: (or) Size............ I Model No. or Size .....MMO.................. Location ..unclergraund.................... Type..gU:.............. Mass. Approval No. ...969....... Permit issued ...................JQk1Y7l..M....F.arrin tAn,.Xhief. - (Head o ire Department By � 'r.f�l.: . . . .........'....... ,. (THIS PERMIT MUST BE CONSPICUOUSLY.,POSTED UPON THE PREMISES) a UO'4MMOTa84 New Salem St. Ph:877.668.2657 Email:infc0comn tank.com tiVakefield,MA 01 S80 600.628,8260 Web:ww wcomrntank.com Fax:781.224.9908 Installation ( Maintenance ( Removal September 24, 2015 Town of Barnstable Fire Prevention 1875 Falmouth Road Centerville, MA 02632 Re: Underground Tank Removal - 97 Outpost Lane, Centerville, MA Dear Fire Prevention: On September 21, 2015 CommTank removed an underground storage tank(UST) at the above referenced address. Attached is the tank closure report following the removal of the underground storage tank (UST) at the above-referenced address. Should you require any further information on this please contact us at 617=628=82607— --- Sincerely, -- - Joanne Cardoza Administrative Assistant l a ' COMIVITANK,ING 84 NEW SALEM=STREET,WAKEFIELD,MA ,TANK:CLOSURE,REPORT; PM:L1 I K(-' To Y t r s CREW: DATE. Jon NAME: goon R1 m ilyi''rs CUSTOMER PHONE# L-Cine CITY: {���'�{� y �.! STATE: rn L�. ZIP CODE: Within:?4 hours after the removal of a UST the owner/operator shall measure for the presence of a release of oil or hazardous materials to the environment where contamination is most likely to be resent on the site. HOMEOWNERBUSINESS OWNER QUESTIONS ;L-Y,PE-OF-SITE(CIRCLE ONE) ..... 'SINGLE FAMILY RESIDENCE_) MULTI-FAMILY RESIDENCE BUSINESS -TYPE n UST-A-GE •..-- Y� YEARS OLD �� YEAR INSTALLED E/UST SIZE In(}00 GALLONS UST FUEL TYPE(CIRCLE ONE) #2 FUEL OIL GASOLINE OTHER a"'IS THE TANKIN`-&E?(CIRCLE ONE) YES NO WHY? ❑ HAVE THERE BEEN ANY ERRATIC CHANGES IN YOUR USAGE OR BILL? NO YES EXPLAIN 0/ ,,'LAST FILL DATE AMOUNT OF LAST FILL GALLONS HAS YOUR TANK EVER BEEN RELINED? Nr(Y YES WHY? d HAVE THERE BEEN ANY SPILLS IN THE PAST? o DATE DESCRIBE ❑' I IS THERE ANY OTHER FLAMMABLE OR HAZARDOUS MATERIALS STORED ON-SITE? ,0/ NO O YES LIST: NOTES: I EACH BOX MUST BE CHECKED BEFORE REMOVAL OF THE-UST V TANK PERMIT FORM#FP.-292 ❑ DIGSAFE # DATE OBTAINED DIGSAFE# 1-800-1322-4844 TANK INFORMATION : FIBERAGLASS` STEEL ' ' 1 CYLINDRICAL TANK Formula For a CYLINDRICAL TANK r / Ir r L x ® x 3.1464 L ID \ / 1 231 gallons 1 tip/ _ ffn L —� D= inches L= I+�® inches o UST SIZE GALLONS o f y J GALLONS OF OIL EMPTIED FROM TANK o GALLONS OF WATER EMPTIED o INCHES OF OIL IN TANK LVCHES OF WATER - 1 - 4i ❑! IS THERE ANY STRESSED VEGETATION OR DISCOLORED PLANTS IN THE AREA? o NO o YES DESCRIBE: ' IS THERE ANY BROKEN OR PATCHED PAVEMENT AROUND OR NEAR THE(CIRCLE IF YES ,TANK FILL PIPES PUMPING ISLANDS OTHER 0 IS THERE ANY STAINING ON/AROUND/ABOVE THE(CIRLCE IF YES TANK FILUVENT PIPES LINE AREA OTHER OZ.,FILL MATERIAL- GRAVEL NATIVE FILL OTHER DEPTH TO TOP OF TANK- FEET EACH BOA:MUST BE CHECKED DURING THE REMOVAL OF THE UST /FD PERSONNEL ON-SITE : NAME TITLE LJ ON THE TANK IS THERE ANY VISIBLE SIGNS OF: 0 HOLES/BREAKAGE DESCRIBE 0 RUST/CORROSION DESCRIBE 0 STAINS DESCRIBE O OTHER DESCRIBE IN THE EXCAVATION IS THERE ANY VISIBLE SIGNS OF: 0 SOIL STAINING DESCRIBE j 0 OTHER DESCRIBE 0 GROUNDWATER EVALUATION: IS THERE GROUNDWATER IN THE EXCAVATION? NO YES IF YES IS THERE: FREE PRODUCT DESCRIBE SHEEN DESCRIBE TABULATE DATE TIME SAMPLE ID SAMPLE DEPTH PID PID BACKGROUND SAMPLER NOTES (M/DD/YY) (0:00 AM/PM) (FEET) (PPM) (PPM) (INITIALS) SIDEWALL 1 0..0 0 SIDEWALL 2�o SIDEWALL 3 © G , •. fLO SIDEWALL4 l PIT BOTTOM 010 " (� PIPING AREA NOTES: 0 ARE THERE PETROLEUM ODORS IN: 0 NEARBY STORM SEWERS—PID READING ppm 0 DRAINAGE DITCHES -PID READING ppm 0 BASEMENTS-PID READING ppm 0 WETLANDS -PID READING ppm ar HAS T TANK BEEN CLEANED? 7OUTSIDE 0�INSIDE - 2 - R -BACKFILL MATERIAL- GRAVEL LOAM SAND WILLPACK OTHER +CI EXCAVATION(CIRCLE.ALL THAT APPLY) 0 LINED WITH POLY O COVERED WITH POLY 0 FENCED IN WITH: SNOW FENCING CHAIN LINK FENCING CAUTION TAPE OF PHOTOGRAPHS TAKEN: 7 PIPING TANK Z EXCAVATION d `#OF DRUMS LEFT ON SITE: CONTENTS: f!� LI. .LOCATION OF DRUMS: (DRUMS CAN NOT BE LEFT ON GRASSY AREAS) �?" #oil TO'fF_S OR FRAC TANKS: CONTENTS: ❑ NOTES: SITE SKETCH: .-T NORTH j '! ���� 0.i Or fin, f ' PLEASE INDICATE: 1.The location of the UST 2.The UST piping 3.Field screening points&laboratory sample co',lection 4.General observations NOTES: ATTACHED DOCUMENTATION ❑ WITHIN 72 HOURS OF CLOSING THE UST,PROVIDE RECEIPT TO THE LOCAL FIRE DEPARTMENT FOR DELIVERY OF UST TO THE DISPOSAL SITE DESIGNATED ON PERMIT ❑ WITHIN 30 DAYS OF REMOVING THE UST,SEND NOTICE TO DPS TO CHANGE REGISTRATION INFORMATION FOR THE UST. FP- 290R ❑ BILLS OF LADING(BOL)OR HAZARDOUS WASTE MANIFESTS USED TO TRANSPORT CONTAMINATED MEDIA OFF-SITE,A COPY MUST BE ATTACHED. ❑ COPY OF FORM FP 292(PERMIT FOR REMOVING UST AND FOR TRANSPORTATION TO TANK YARD) ❑ COPY OF FORM 291 (RECEIPT OF THE UST AT DISPOSAL FACILITY,INCLUDING STATE LICENSE NUMBER OF FACILITY). - 3 - 0 Within 24 hours after the removal of the UST, measure for the presence of contamination at locations where it is most likely to be present,as required by 527 CMR 9.07(K�(4). Steps 13 through 15 describe DEP and DIPS recommendations for ftllfilling this requirement. �r <p' TABLES t TABLE 1: Summary of Follow up Procedures to Heads ace Screening RESULT ACTION Readings> 100 ppmv 1. Notify the DEP within 72 hours 2. Notify the local Fire Dept. Reading<100)pmv, but>ambient air Obtain a minimum of one sample for lab analysis Readings<or=to ambient air Gasoline only Assume"clean" Fuel oil only I composite sample for lab Other contaminates 1 composite sample for known/suspected contaminates >Greater than <Less than 1`abl�:CL Arimle'Ikctl MeavAi for lk-imleum rol&tcbs Petrokurn.ITixi(Ju t Soil€a•SealerMn ria: 1r1'Alt'Cc :tnitivyieal t.Ietbailk, C tsoli.nc Anil himihtr�! ci hl: voc: 8020..8240 82G0,ur DEP-1%PI-1 P6�ilUvr: IIIethAC14 6, Fuel 011s N0 2.4.5,t) ` ocs 50 0.S240.82r.0.or DEI'-VI?I-I Dies-I..Lulirion[in--Oils.and similar method, y'I r::rr,327fs,ar Il E P-1:.P H PA 1-1 metlnul"s GC.FI D or 41 S.l TPkI Unknown l'i�.urk tun Product Vacs. 5 40.S260,or DEP-VPi-1 rrzetho& PAII 810fl.827t).or-1_)EP-17PFI method-l" C:iC`s FiD "I he I3EP Fos le iped INYO m.thc�la for Cktcmrining die,aincrnt:r Lion of[x[rckunr Iwdwcnluoa iu •Dater and:oil to_omplenzent.and SupPont d,:t0ucciho,'1r0r DI)PI-xnch tOCV-1 ILIA r:htrilvin N_aIth lviznnds dial mav re—Al It from cv:"as€n-ets such corn punds. "hhe sIkkthod tbrdie Dek{rtninatrem of I sn'oct.able Pen-C,Im0) .Vd.R:A.1.rb0ns 1014) collcCt:i;cl; n)casures die concentrrrions of cxtrrciaW aliphatic :and arematie h:edrocurixir, at).l indi;idual conwen ations of PA13:s. The Medicol for the lkrcnninntioii of Vo:stile Petroleum Gl ydruca.dxonc: .nr:isure collection commanntions of vo Intik aliplrsrtic a.nd mmAral:ic Irr dmerulx,ns :u.ch as l3 f E\I i urcne.:ToII.Me.Ethel L::naene.\y l 10- I'Nlale.ill: Sturm ary(fzy:ICJ'Itep:ortablc•C:a uclitions and Itquircrtlxntc for NaAdicat on to!DEll Condition I"ins frrtnc Gruatertha.n 1 LEI_ hour; Re1aa:.c of.realer dzan 10.L!,allorr.in'_4 hours hours Elends ace rrenxrtha.n 100 3 rnv 72 Ir_ur NAM atp.c te:rthanore ua.11m lt'2" 721 Yairs Covol entntiorrcreatzrtlxin RCsin!_nxind water wiIi.in 4C I[,of p ub I'Y.l iantcr yt1.7)ly or50) `:boor.. fl:o:f..r-ic'aae•c:�t�r>n z zlv. 4°iOC's ill{wru.nd Y iltr;at 15 ft bdo-a-round stflxe=,z,5 m 'L widnn'r)ft of I-ours ':choolrxcupied v:ructux. Coticentntions 120 cbys '^NoLifiontion io DEP may notbe rcquircd.il'a Limi,ird Removal_tenon can br talon. _'fable IV: MCP Reportable Concentrations for Selected Petroleum Constituents ANALYTE SOIL WATER ]mg/kg) m /L RCS-1 RCS-2 RCGW-1 4 RCGW-2 Benzene 10 100 0.005 2 Toluene 30 300 1 4 - 4 - Ethylbenzene 80 1 500 11 0.7 4 X lenes(total) 500 500 6 6 Total Petroleum Hydrocarbons(TPH) 200 2000 0.2 j1 Slatripliniz Locations �o 1=1.11 k'iltio .Y ��' [)t�l i••••:�r~, l_i Ire N VA l� �t y n SIDEWALLSPIT BOTTOM A 4 + Ilntili_€.in=ihpidsilialidaandtruizporiol rl2trt�lunnil�til-I_•tiksiuJlr:,Iruli,ileal}�;>urapilh•:':,i..4. I�fIIIIJII�•'r'.'��CF-f';III � _- �' ,4� a y ✓ a x Fr flcot ing Rod G,I'iiUl1 I':? Il ei RECEIPT OF DISPOSAL OF UNDERGROUND STEEL STORAGE TANK i FORMERLY CONTAINING MOTOR FUEL NAME AND ADDRESS OF APPROVED TANK YARD: Minichlello Bros. 2 Dexter Street Everett,MA 02149, I li Approved tank yard no. 016 Tank Yard Ledger 502 CMR 3.03(4)Number: I carlify under.ponaltyaf taw I have personally examined the underground steel storage lank delivered to $his approved tank yard"by(firm.corporation or partnership) domm TANK and accepted some In conformance Willi Office of the Slat®Fire Marshal Regulations 502 CMR 3.00 Provisions for.Approving Underground Steel Storage Tank Dismantling Yards.A valid permit was issued by the head of the LOCAL Ore department FDID# D1920 to transport this lank to this yard. Name and official title of approved tank yard owner or owners authorized representative: Signatu lie: Dispatcher Date signed: 9/22/2016 �!TANK DATA: TANK REMOVED FROM: f Gallons: 1000 Ida.and Sireet: 97 OUTPOST LANE; : ` i€rvl0u ' nQealts FUEL OIL City and Town.' CENTERVILGE;MA Diameier: Fire Dept.Permit 9. 07852 Length: Notes: Date Received: 9M/2015 Serial#(it available): Tana I.D.#(Form FP-290); L'ACH TANK MUST HAVE A RECEIPT OF 01009AL Owner/Operator to mall revised copy of Notification Form(FP290, or F1329011)to local fire department and: Department of Environmental Protection Bureau of Waste Prevention- UST program .P.O. Box 120-0166 S0ston, MA 02112-0165 r'h19 signed r®oeipt of disposal must be returned to the head of the local fire department. Forri FR'291 (t�ev 99I2Q09) i s