HomeMy WebLinkAbout0009 PARK AVENUE - HAZMAT 2,D8- b2CF, .:e ELLIS 6? THULIN, INC. LAND SURVEYORS & CIVIL ENGINEERS 478 ROUTE 6A-P.O. BOX 159 DAVID C.THULIN, PE EAST SANDWICH, MASS. 02537 JOHN R.ELLIS, RLS TELEPHONE (508) 888-2345 January 8. 1993 Board of Health Town of Barnstable 367 Main Street Hyannis, Ma . 02601 ref . 92-055, 9 Park Avenue, Centerville, Ma. Dear Board Members: The enclosed plan shows existing and proposed site conditions at the ref . address. The building is to be occupied by persons under the care of the Cape Head Injured Persons ' Housing and Education Group. It will have eight bedrooms. According to your regulations, design parameters for septic systems for buildings having more than six bedrooms must be set by your Board . Please place consideration of this proposal on your January 28 agenda and notify me of the time and place of the hearing . Feel free to call prior to the hearing with your questions or commen Very/ my 011 GG� llis & Thulin , Inc. by David C. Tihulin , PE cc. Royden Richardson , C.H. I .P Antonia Kenny , A. I .A 4_1 :w v 4, 0 -777�­ 7�, -2. lim r- T 's, 109" T. 047, 47 t 7 Y A; Z r Ln POND 0 03 SITE DATA Cn A A PLA Lli LOCUS x V) 0 KNOCKOUT (TYP) 1 5 SORS LOT 26MAP 208 99 r I RO. m 7 COMPUTED LOT AREA 13014± SF - 0.30 ACRES to 0 < Cv OWNER - COMMONWEALTH OF MASSACHUSETTS V) L IX DEPT. OF CAPITAL PLANNING AND OPERATIONS 4"0 SCH40 PVC (TYP). CENIIERIALLE DIV. OF MENTAL HEALTH TBM - SPIK�E IN POLE 29/2 < ELEV. 100.00 ASSUMED REFER TO BOARD OF HEALTH PERMIT 81-405 AND PERCOLATION TEST APPLICATION P-4923 PLAN < C) ink' 0 (D Ljj 0 TION AT OUTLET INLET 2" LEVEL SEC z AND PARKING AREA 2000 0 1000 2000 4000 2 0 fo I' - 2000 FEET C.) SIDEWALK CE 9 1/2- J 7 1/2- J F-� ADDITION < EDGE OF PVMT.CONC SECTION A- A EXIST. 1500 GAL SEPTIC TANK TO BE RELOCATED d NOTE: -50 10, CoNc. DISTRIBUTION BOX TO BE SET ON FIRM 4 0 LEVEL GROUND. OUTLE PIPE INVERTS 1/16 INCH±. TO BE SET AT SAME ELEVATION WITHIN 4 �j A A 18" OPNG OUTLINE OF EXISTING BUILDING 3 OUTLET DISTRIBUTION BOX. loo -091 1/2"PROPOSED.1500 GAL TP2 SEPTIC TANK 02 PT < SILL 5" KNOCKOUTS (TYP) LP1 DB ELEV. 103.67 w jr EXISTING LEACH PIT LIGHT DUTY C.I. COVER 0 GRADE TO,BE RELOCATED iO3 'BRICK ADJUSTING COURSE R PLAN 18" ID RESIDENTIAL RISER 1pi st. LP2 LEGEND LEACH PIT 1`0 6 .44ON LEACH PIT 4 R ' PEASTONE 3 EXISTING CONTOUR r OUTL E OF 00000 00 00 00 00 00000 _ 60000 00 00 00 0000004 PROPOSED DECK ' 70.2 3/4" 3/4"'**- 600000000 000000000 EXISTING SPOT ELEVATION LLJ x TO TO 400000000 0000000004 [1021 0 0000000 000000006 PROPOSED SPOT ELEVATION WASHED #000000 00 00000000# wv WASHED 0000000 00 00 0000004 STONF, STONE ui to 000000000 00000000# 0000000 00 00 0000006 UTILITY POLE W- UG. WATER MAIN 6o-O' IF PvMt. G GAS SERVICE DIAMETER VARIES .,TOPOGRAPHIC INFORMATION AND DETAIL.TAKEN FROM TIC SYSTEM "EXISTING"SITE PLAN" FOR THE COMM. OF MASS; BY . SEE SECTION THRU SEP HYDRANT ANDREW AGAPOW, FEB. 1983, 1" = 10. FIELD CHECKED 3 12/29/92 SY ELLIS & THULIN, INC. UTILITY POLE SECTION THRU CENTERLINE BUILDINO LOCATION FROM FIELD SURVEY' SEPTEMBER 1985 E O.H. CABLE UTILITIES z ON LEACH PIT GUY "RE 0 3 V) 0" 1/4" 1"' TAPER > _CTION A-A Sl TE PLAN. S E 20 10 20 40 1500 GALLON SEPTIC TANK 0 -n IN FEET LJJ F- Z 1. Inch 20 ft. 1 /2" 1 01) < uj SOIL TEST DATA uj ui u- > _j 0 110 DATE: SEPT. 6,1985 EXCAVATOR: DRISCOLL B.O.H. AGENT: J. CONLON ENGINEER: ELLIS & THULIN, INC., TOP FND. 103.7± LOCATION: TP1 XISTING SEP11C SYSTEM D Sl GN DATA, ' 105 LOCATION: TP2 ELEV. DEPTH 8 I.D. LD Cl�COVER �(TYPICXQ 103.5 0.0 ELEV. DEPTH 102.8 0.0 z LOAM AND SUBSOIL DIST. BO)( LOAM AND SUBSOIL 0 t9.73 9.�2 SEWAGE FLOW ESTIMATE 101.0 2.5 SOURCE GPD COMMENT > 0 z F, Cm 100 AND 99.8 3.0 SINGLE FAMILY RESIDENCE BED oom 1 110 8801310 R 15.02 (1 F 8 1 36 F 4' Pvc GRAVEL Ld uj AND GRAVEL ^IMATED PEAK DAY FLOW 98.5 5.0 9.32 S-0.010 TOTAL ES 880 CLEAN 99.32 ol V) MEDIUM S-A020 4' PVC 96.8 6.0 4* Pvc 4, Pvc I., SAND UJ MEDIUM SAND -0.020 S-0.038 SEPTIC TANK Z 60T. SME 93.32 LL t _j z < TOTAL FLOW X DET. TIME 880 GPD X 1.5 DAYS 1320 USE 94.3 8.5 1500 GAL. TANK 1500 MEDIUM SAND t 0 GALLON z < uj SEPTIC, I- (]:� TR GRAVEL LEACHING FACILITY LP1 6' X /2 STONE Z: z '-TANK u 6' LP W LLJ LEACHING PITS STONE LEACHING AREA CAPACITY 90.8 12.0 U) oo tLj BOTTOM NO. DIA DEPTH SIDE �BOTTOM SIDE BOTTOM SIDE 90 -------40 CL m a- z (ft) (ft) (ft) (sf) (gpd) (gpd) (gpd < un NO G Ld (ft) (Sf)ROUNDWATER 10.6' z 1 2 1 6 1 6.0 2.0 0.0 1 188 1 78 1 942 1 157 1 1099 a U) 0 a_ 87.5 16.0 PERCOLATION RATE: 2.0 MIN./IN. LEACHING RATE: GPD/SF SIDE 2.50 BOTTOM 1.00 o 0 m 40. .8, 2' BOTTOM NO GROUNDWATER 85 sS' S EPTI C YSTEM SECTION THRU .. ... in. 0 ft. HORT. 'I in. 5 ft. VERT. 9 2 ' 055 SHEET .1 'OF '1'­' 2'