Loading...
HomeMy WebLinkAbout594 BEARSE'S WAY -- --- I., c �, f Commonwealth of Massachusetts Town of Barnstable .200 Main Street- 508 862-4038 BOARD OF FIRE PREVENTION REGULATIONS APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK J) Permit No: TE-17-966 Date Received 5/15/2017 Job Location: 594 BEARSE'S WAY, HYANNIS Map Parcel 293-046 Contractor's Name: Neil A Madden Phone: (781) 858-9067 Contractor's Address: 21 HUNT ST State Lic. No: 22076 .READING, MA' 018672438 License Type: Master Electrician Class A Home Owner's Name: THIRTEEN SAC SELF-STORAGE CORP Home Owner's Address: 1250 E MISSOURI AVE Home_Owner Phone: (508)771-9767 Work Description: INSTALLATION OF UNDERGROUND PVC ELECTRICAL CONDUIT FOR FUTURE BUILDING LIGHTING AND LOW VOLTAGE WIRING. CONDUIT WILL BE RAN FROM MAIN BUILDING TO OTHER REMOTE BUILDINGS IN-THE REAR Utility Authorization No. Details: No.of Recessed Luminaries: 0 No.of Cell.-Susp(Paddle)Fans 0 No.of Transformers 0 KVA 0.00 No.of Luminarie Outlets: 0 No.of Hot Tubs 0 Generators 0 KVA 0.00 No.of Luminaries: 0 Swimming Pool 0 No.of Emergency Lighting Battery 0 Units No.of Receptacle Outlets 0 No.of Oil Burners 0 Fire Alarms Zones 0 No.of Switches 0 No.of Gas Burners: 0 No.of Detection and Initiating Devices: 0 No.of Ranges: 0 No.of Air Conditioners: 0 Total Tons 0.00 No.of Alerting Devices 0 No.of Waste Disposers: 0 Heat Pump. Number Tons KW No.of Self-Contained Detecting/ p Totals: 0 0.00 0:00 Alerting Devices No.of Dishwashers 0 Space/Area Heating KW 0.00 Type of Connection 0 No.of Dryers 0 Heating Appliances: 0 KW 0.00 Security Systems 0 No.of Water Heaters 0 No.of Signs 0 No.of Ballasts 0 Data Wiring: 0 No.of Hydromassage Bathtubs: 0 No.of Motors 0 Total HP 0.00 Telecommunications Wiring: 0 Others: 'HIS ISNOT A PERMIT Commonwealth of Massachusetts Town of Barnstable 200 Main Street- (508)862-4038 BOARD OF FIRE PREVENTION REGULATIONS APPLICATION FOR PERMIT TO PERFORM;ELECTRICAL WORK Panels: ES Amps: 0:00 ES No Meters: 0 NS No Meters: 0 ES Volts 0 New Amps: 0.0.0 NS Underground: False ES Overhead: False New Volts: 0 Sub Panel#: 0 ES Underground: False NS Overhead False Sub Panel Amps: 0 FOR A SERVICE CHANGE, A HOMEOWNER CANNOT CUT &TAP. A CUT &TAP MUST BE DONE BY AN E- 1 ELECTRICIAN WITH A PERMIT OR THE POWER COMPANY. Estimated Value of Electrical Work: 6,000.00 Work to Start: . 05/15/2017 Inspections to be requested in accordance with MEC Rule 10, and upon completion. INSURANCE COVERAGE: Unless waived by the owner, no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including "completed operation" coverage or its substantial equivalent. The undersigned certifies that such coverage is in force, and has exhibited proof of same to the permit issuing office. Insurance Coverage: None:Specified I certify, under the pains and penalties of perjury, that the information on this application is true and complete. Company Name: , Neil.Madden 5/15/2017 (781) 858-9067 Signed: Applicant Date Telephone No. If the licensee does.not have insurance, then the Owners Waiver must be signed, and attached to this Permit Application. *Per M.G.L. c. 147, s. 57-61; security work requires Department of Public Safety"S" License: *IMPORTANT:A separate permit is required for the installation of smoke detectors.Fire Alarm inspections are performed by the FD having jurisdiction. Estimated Construction Costs/Permit Fees . Date Paid Amount Paid Check#or CC# Pay Type Total Project Cost: $6,000.00 5/15/2017 $75.00 XXXX-xXXX-xxxX- - Credit Card 7964 Total Permit Fee: $75.00 Total Permit Fee Paid: $75.00 THIS IS NOT A PERMIT Commonwealth of Massachusetts Town of Barnstable '.<. 200 Main Street- (508)862-4038 BOARD OF FIRE PREVENTION REGULATIONS APPLICATION FOR PERMIT TO PERFORM,ELECTRICAL WORK Permit No: TE-17-966 Date Received: 5/15/2017 Job Location: 594 BEARSE'S WAY, HYANNIS Map Parcel 293-046 Contractor's Name: Neil A Madden Phone: (781) 858-9067 Contractor's Address: 21 HUNT ST State Lic: No: 22076 READING, MA 018672438 License Type: Master Electrician Class A Home Owner's Name: THIRTEEN SAC SELF-STORAGE CORP Home Owner's Address: 1250 E MISSOURI AVE Home Owner Phone: (508) 771-9767 , Work Description: INSTALLATION OF UNDER GROUND PVC ELECTRICAL CONDUIT FOR FUTURE BUILDING LIGHTING AND LOW VOLTAGE WIRING. CONDUIT WILL BE RAN FROM MAIN BUILDING TO OTHER REMOTE BUILDINGS IN THE REAR Utility Authorization No. Details: No.of Recessed Luminaries: 0 No.of Cell.-Susp(Paddle)Fans 0 No.of Transformers 0 KVA 0.00 No.of Luminarie Outlets: 0 No.of Hot Tubs 0 Generators 0 KVA 0.00 No.of Luminaries: 0 Swimming Pool- p No.of Emergency Lighting Battery 0 Units No.of Receptacle Outlets 0 No.of Oil Burners 0 Fire Alarms Zones 0 No.of Switches : 0 No.of Gas Burners: 0 No.of Detection and Initiating Devices: 0 No.of Ranges: 0 No.of Air Conditioners: 0 Total Tons 0.00 No.of Alerting Devices 0 No.of Waste Disposers: 0 Heat Pump Number r Tons KW No.of Self-Contained Detecting/ 0 Totals: 0 0.00 Alerting Devices 0.00 No.of Dishwashers 0 Space/Airea Heating KW 0.00 Type of Connection 0 No.of Dryers 0 Heating Appliances: 0 KW 0.00 Security Systems 0 No.of Water Heaters 0 No.of Signs 0 No.of Ballasts 0 Data Wiring: 0 No.of Hydromassage Bathtubs: 0 No.of Motors 0 Total HP 0.00 Telecommunications Wiring: 0 Others: THIS IS 1400T A PERMIT- Commonwealth of Massachusetts 4 s Town of Barnstable •200 Main Street-(508)862-4038 BOARD OF FIRE PREVENTION REGULATIONS APPLICATION FOR PERMIT TO PERFORM:ELECTRICAL WORK Panels: ES Amps: 0.00 ES No Meters: 0 NS No Meters: 0 ES Volts 0 New Amps: 0.00 NS Underground: False ES Overhead: False New Volts: 0 Sub Panel#: 0 ES Underground: False NS Overhead. False Sub Panel Amps: 0 FOR A SERVICE CHANGE, A HOMEOWNER CANNOT CUT & TAP. A CUT & TAP MUST BE DONE BY AN E- 1 ELECTRICIAN WITH A PERMIT OR THE POWER COMPANY. Estimated Value of,Electrical Work:. 6,000.00 Work to Start: 05/15/2017 Inspections to.be requested in accordance with MEC Rule 10, and upon completion.. INSURANCE COVERAGE:.Unless waived by the.owner, no permit for the performance of electrical work may issue unless .the licensee provides proof of liability insurance including "completed operation" coverage or its substantial equivalent. The undersigned certifies that such coverage is in force, and has exhibited proof of same to the permit issuing office. Insurance Coverage: None Specified I certify, under the pains and penalties of perjury, that the information on this application is true and complete. Company Name: Neil Madden 5/15/2017 (781) 858-9067 Signed: Applicant Date Telephone No. If the licensee does not have insurance, then the Owners Waiver must be.signed,and attached to this Permit Application. *Per M.G.L. c. 147, S. 57-61, security work requires Department of Public Safety"S" License: *IMPORTANT:A separate permit is:required for the installation,of smoke detectors.Fire Alarm inspections are performed by the FD.having jurisdiction. Estimated Construction Costs/Permit Fees Date Paid Amount Paid Check#or CC# Pay Type Total Project Cost: $6;000.00 5/15/2017 $75.00 xxxx-xxxx-xxxx- Credit Card Total Permit Fee: 7964 $75.00 Total Permit Fee Paid: $75.00 THIS IS NOT A PERMIT [JARNSIMILTOWN OF BARNSTABLE '79 OCT -4 AM 9 11 Board of Appeals .HarmHarmon R......S.tonp A A.1 Kgp 7............. Deed duly recorded in the ...................................................... on ............w..p agmi ].An F George A. Colley, Jr. Property Owner County Registry of Deeds in Book .......................... Siam as above,....................................................................................... Page ........................I ..........................................................Registry Petitioner District of the Land Court Certificate No. ........................ ........................ Book....................... Page .................. Appeal No. .........1979-59 October 2 1979 ............................................................... .................................. FACTS and DECISION Petitioner .........ato.J.19*� P......5 KAP,'Lan .............................. filed petition on Auaus.t..3................ 1979 G.A. Colley. Jr. requesting a variance-permit for premises at Re.a..r.s.e..'..s Wax•.........................................Wk*, in the village of ...................H.Y.annl.s.................................................... adjoining premises of ...........(§.tt attached I.J.A.t.).................................. ........................................................................................................................................................................................................................................................................................... .......................................................................................................................................................................................................................................................................................... ...................................................................................................................................................................................................................................................................................... ............................................................................................................................................................................................................................................................................................. for the purpose of aP-9-QJ.A-1 P.e.r.r D.Lt AnAgr.... RA of the Barnsitahl.p............................ Zg!I.i.ng hy-.1.a .!2 Lod fl..ah Px .l.an-t W_Wusdneas zanad di.516S.t................. t Locus is presently zoned in RugJ..n.e..s.s............................................................................................................................................................ . ..... .... Notice of this hearing was given by mail, postage prepaid, to all persons deemed affected and Cape Cod News & by publishing in Barnstable Patriot newspaper published in. Town of Barnstable a copy of which is attached to the record of these proceedings filed with Town Clerk. A public hearing by the Board of Appeals of the Town of Barnstable was held at the Town Office Building, Hyannis, Mass., at ..............7 0 0.............YAX W P.M. ...................Augmat 3.0................................. 1979 upon said petition under zoning by-laws. Present at the hearing were the following members: Richard L. Boy Frank P. 0 Congdon Gail Nightingale .. .................................................... ................................................................................... ................ ...................................1 ............................ Chairman ................................................................................... .................................................................................... .............................................................................. At the conclusion of the hearing, the Board took said petition under advisement. A view of the •locus was had by the Board. a AppealNo..................i.575-59.............................. Page ....... ............. of ...........3.......... On ...........September 27 19 7�:......... The Board of Appeals found ......................................_.........._..... , Atty. Phi.li:p M. Boudreau represented the petitioners who are seeking a special permit to allow a fish processing operation at the former Hood's Milk Co. building on Bearse's. Way, Hyannis in a business zoned district. Application is made under Section P. (18) of the zoning by-laws which requires approval ' by the Board of Appeals for a manufacturing use in a business zone; or a special permit for a use which is nonconforming; or as an appeal under Section 8 of Chapter 40A, M.G.L. from the decision of the Building Inspector. Fish will . be processed by washing, filleting, packaging,and freezing and storing. The packaged fish will then be sent to wholesale distributors for -further processing and also overseas to various countries. After its final processi;ng,, the fish is sold to schools and institutions. Mr. Boudreau displayed the type of carton which would be used to package the fish fillets and these packages w't11 range in size from 12 lbs. to 5 lbs. The old Hood's building now comprises approximately 23,000 sq. ft. and office space in the building is now used by Cape Dairy Products, the distributor for Hood's Milk Co. products. Cape Dairy Products will be in the building for a few additional months and they now occupy only a small area. The petitioners anticipate gross sales of ten million the first year, and will initially employ about 50 people with eventual employment of 100 or more. Reassurance was given to the petitioners by the Selectmen, the Dept. of Public Works, and the Board 'of Health, that the use would be permitted and it was not until the petitioners bonding counsel requested certification that the use was protected under zoning, that a problem arose. The Building Inspector who had previously agreed that this was an allowed use, changed his opi:ni:on and advised the petitioners that they would have to file with the Zoning Board of Appeals for a special permit. Atty. Boudreau gave a history of zoning in. the town and said that manufacturing uses do exist in this same business zone which do not have Appeals Board approval and made particular mention of the candle company which manufactures candles and is in the immediate area of the locus in question. There is some question as to whether or not the use by the Hood' s Milk Company constituted a non-conforming use. Therefore, the petitioners application could be for a change of a non-conforming use, an appeal from the decision of the building .inspector, or application under Section P (18) . The petlti'oners would construct a small addition which would be used as an engine room and whi:ch. would measure approximately 30ft. x 40ft. The proposed use would not promote noxious or offensive odors since there would be no 'cooking or canning of fish but only the freezing and packaging of raw fish and the entrails, heads, fins, and tails will also be frozen after they. have been ground up,and shipped out for processing. (.� n (cont.) I, ......1 [11..N... :...... .`. �? 0�. /I S Clerk of the Town of Barnstable, Barnstable County, Massachusetts, hereby certify that twenty-one (21) days have elapsed since the Board of Appeals rendered its decision in the above entitled petition and that no appeal of said decision has been filed in the office of the .Town Clerk. Signed and Sealed this ... .G........... day of © ......... 19? ................. under the pars} an ?........................... . penalties of perjury. Distribution:— Property Owner .......:.....................t . ................. ........................... ...:.. .............................. ......... � ... Town Clerk Board of Appeals Applicant Town of Barnstable Persons interested Building Inspector PublicInformation BY .................._............................................................................ Board of Appeals Chairman BOARD OF APPEALS SAINS Appeal No. 1979-55 Page'3 of 3 The petitioners will operate th.is business as a co--partnership and between them have the expertise necessary for a successful operation, Mr. W. John Braden spoke in favor of the petition and is the real.tor handling this property. Norman Moore and Robert Conway spoke in favor of the petition and said that the town needs this type of business which will provide employment for many people. Ernest Henderson who owns land at Bearse's Way, said that he had no objection to the petition if the statements made were correct and hi's land value would not be adversely affected by the petitioners use. Mr. Colley said that rigid inspection of this oper- ation would be made by a U.S.D.A. inspector who will be on the premises at a.11 times. The fish supply to this plant will come from several locations on the Cape, from Point Judith, and possibly from Gloucester and New Bedford. No one spoke in objection to the petition and the Board took the matter under advisement. The Board found that the petitioners' application was properly made under Section P. (18) of the Barnstable zoning by-laws, which permits a manufacturing use in a business zoned district by special permit granted by the Board of Appeals. The petitioners' proposed use will not be detrimental to the neighborhood; will provide increased employment in the town, and will not derogate from the spirit and intent of the zoning by-laws. The Board voted unanimously to allow the petitioners a. special permit under Section P. (18) subject to the following restrictions: i 1 . There shall be no additions or alterations to the exterior of the building with the exception of the 30 ft. x 40 ft. engine room as shown on the. peti.ti'oners' plan. 2. All parking relating to the petitioners' operation and use, shall be contained i`n the paved area of the petitioners ' property which lies within the existing chain link fence located on the property line abutting Bearse's Way. 3. There shall be natural cedar screening to consist of live cedar trees, th.ree feet high at the time of planting, conical i..n sh.ape, and planted at four foot intervals along the existing chain link fence bordering the petitioners ' property and Bearse's Way, 4. The acti.vi:ty at this location is limited to washing, filleting, packaging and fr.eez.ing of fish, with storage on the premises of fish in i,ts frozen state. Any, other use of the premises which does not directly relate tot he previously mentioned allowed activity is prohibited. There shall be no cooking, canning, or processing of fish which shall alter its original composition. Receiving and shipping of fish which is necessary to the operation . of this business is allowed. Appeal No.. ..........1._7.1..:..t.....1..u...�............_ TOWN CLERK t L. oaTHeror WNSTAO!E.MASS. o" � Date Reeeiv d........................................................._ •� HAUSTAIL i �1 �• I '79 AUG —3 PM 35 '°oe��6Js`• �e0� "`'l9�`f '' 'EONPY�' • 1 TOWN OF BARNSTABLE • i VAS`CE UNDER THE ZONING BYLAW PETITION FOR SPECIAL PERMIT To the Board of Appeals, Hyannis, Mass. Date_...A119115.. .....3........._...19_1...9....._ The undersigned petitions the Board of Appeals to vary, in the manner and for the reasons hereinafter set forth,the application of the provisions of the zouiug by-law to the following described premises.. Applicant: .___See _addenda..._"A"..,attached_hereto.___..._.._.._....._............_..............................................................._ (Full Name) (Winter Address) I Same_-• ._ ......................_.._.._....... ._...._._._.._.............._......................................-- - Owner: __.._.._..._................ ...._ ........._._.._..._............__......-...__.-_- (Full Name) (Winter Address) Tenant (if any): CaPe.._Dairy__Produ.... f.„.Inc.t..._...._._............_............_._..._._.__......._.._._...___._.— j (Fun Name) (Winter Address) 1.Assessors map and lot number ..__Map 293.................I!ot---46..._..._....._..............................................................__...... _ Bearse's Wa, H annis 2.Location of Premises _......_.(N93-oi-sc'eeti�.ayeragDed epth 400'n,ot^Tggare t',.2'2-`7 &)�� ✓3. Dimensions of lot__.___�.3.$• Y (Frontage) 4. Zoning district in which premises are located_._....................Bus.iness_..._.._.....---.___.. ........_.__.......................................... 5. How long has owner bad title to the above premises? _.__.___-.__�1u.lY...... _w......�979 6. How many buildings are now on the lot? __.___._.._........_..Qblt......__..__.___._--__...._._.............._._._......__........__..__ Y 7. Give size of existing buildings ____ _. ,. 5.. • ...^• Proposed buildings 8. State present use of premises Distribution of__dairy„products & offices connected _._......_._. the'revith ant, including, the preparation, 9. State proposed use of premises F].Ski, P✓"•Q•t*•�1S•••sAn F --- freezin4, and dis ribuul6 of"'"fi 10. Give extent of proposed construction or aiterat)ous: ..._......_........._.__.....__................._._............................_.............. _S.ee._glaI)....5_uk?m]tk. .d._.he> Wl..kkl,_G.J3------f .� 11. Number of living units for which building is to be arranged __..—._—. 4..ne........................................_....._...— Y 12.Have you submitted plans for above to,the Building Inspector9 —_—..........es_ .-......._..._..__. 13. Has he refused a permitl________XP.S---.._._....._......_........_._—___�_..._.__....__.....__.._.._................_.._....._._ 14. What section of Loning by-law do you ask to be variedl .____..-_---............_................................................_•._._... Relief, in the alternative, as set forth-in Addenda "B"_attached hereto. _—__.—_..._.-..__..............._.__— ....._._...._........_......... _.._.__.....____ 15. State reasons for variance or special permit: _._._.......__...__..-___....— See Addendaattached hereto _.— —_........................_......_......_ —. .—._.-- ....._......................_._...__.._......_------ Respectfully submitted,, Petition received by (Address) Hearing date set for— 19 _ • Filing fee of $25.00 required with this petition. G -�tiTr�ta • This form may also be used for Appeals. n� J (OVER) �jLG(.T_sc 6L-/�sK.ri/t i'"✓�Q.. U Z�� 6 U 9 ADDENDA "A" Harmon R. Stone, 1428 Commonwealth Avenue, West Newton, Massachusetts, David B. Kaplan, 63 Atlantic Avenue', Boston, Massachusetts, George A. Colley, Jr., 558 Commercial Street, Provincetown, Massa- chusetts, Co-partners doing business as C.S.K. Realty. ADDENDA "B" 1 The Petitioners petition for the following action: 1. on appeal from the decision of the Building Inspector denying a building permit for the alteration of the building on the I subject premises for the contemplated use of said premises as a fish processing plant, including the preparation, freezing, and distribution of fish, a decision or interpretation of Section K•.1 of.the Barnstable. Zoning By-Law that.said use is a permitted use in a Business District as defined in Section K, or alternately, 2. To grant a Special Permit under Section P.18 of the Barnstable Zoning By-Law to allow use of said building and premises as a fish processing plant, including the preparation; freezing, and distribution of fish/as a manufacturing use; or, alternately, 3. To grant a special permit under Section P.6 of the Barnstable Zoning By-Law to allow use of said building and premises as a fish processing plant, including the preparation, freezing, and distribution of fish; by way of change of anon-conforming use. a Subdlvisicn of Lot 2 Shown. or. Plan: 27107B Filed .jSth Cert. of Title No. 22034 Heglstry District of Barnstable County ,eparate certifeates of title may he issued for land hown hereon as i4t4._Ift f4V 4--------------------- y the Court. Copy of rt of plan LAND R£61S R�TtON OFAICE Scale of this plan/412 feet to an inch R.L.Woodbury.Engineer for Court U 9 ADDENDA "C" Reasons for granting the above relief: 1. Subject use falls within the classification of "other ordinary business. use of a similar nature"under Section K. l.i. of the Barnstable Zoning By-Law in view of the dissimilarlity of the specified permitted uses enumerated I in said K and the existing uses now carried on in the Business District. 2. Subject use falls within the category specifically excepted by Section P.18 of the Barnstable Zoning By-Law, the granting of a Special Permit would be consistent with the spirit and intent of the Zoning By-Law, and these would be no substantial detriment to the public good or the neighborhood affected, thus meeting the criteria set forth in Section Q.3 (a) and (b) of said By-Law. 3. Viewing the prior and existing use of the subject premises as a non-conforming use, the change•of such use to the proposed i use under Section P.6-of the Zoning By-Law would meet the cri- teria for Special Permit set forth in Section Q.3. (a) and (b) of said By-Law, and would not result in a use more detrimental to the neighborhood. 1 i l J I � ' i Subdlvlslcn of Lot 2 Shover: on Plan. 27107B Filed alth Cert. of Title No. 22034 Registry District of Barnstable County .7eparele certilcates of tide may be issued for land shown hereon as 6?t4__3 9rvl 4--------------------- Copy of it ofP/ao gy the Court. —�,�'In_ LAND REGISTRATION OffICE Scale of this plan AV, feet to an inob ----------- - -- R.L.Woodbury,Engineer76rCourt U .��.y.a.a..a��• aun• va a.n,vv a�v OHlllvJlMOL.L \[ll., �O I VO �, Sch field Brothers, Inc. David L. Mead, Surveyor tied May 1973 N � o 3 � � C. h h C'. 0 i ti, .o m r a`� .�jo�•9y rl+ 2 `0 r� Ir 93 A a ,Q Brick & —1 o x C04crete _J s,^k r®, p L LU o Sp.. 5 s 6 p q3�iy s 55' 09' so' w oo. t Ap - ra >ubdivisicn of Lot 2 I ;ho•.T.. or.. Plan. 27107E Sled with Cert. of Title No. 22034 eglstry District of Barnstable County eparale certificates of title may be issued for land iown hereon asJ_eJ_j__;�OM --------------------- Copy of rt ofplea the Court. —/' " LAND REGISTRATION OFFICE •Scale of this plan/GPI feet to an inch Reco er. Y, 9 R.L.Woodbu� En hnterBeCourt U v Town of Barnstable oF1HE r�,, Regulatory Services - '1'o Richard V. Scali,Director Buildin Division BARNSTABLE • MMSTABLE, • 9aarisr4wt•ccxxceviu2•cciurt•naxxs MASS au Roma,$ Paul Rxx9,�,�Ea,E. 9� i63q. 10 , 16.39.2014 ATED sA Building Commissioner 575 200 Main Street, Hyannis, MA 02601 www.town.barnstable.ma.us Town of Barnstable Certificate of Zoning Compliance Certificate 2017-02 - ..map 293 Record Owner: Parcel 046 Address 594 Bearse's Way Thirteen SAC Self-Storage Corp. Village Hyannis 1250 E Missouri Ave. Phoenix, AZ 85014 Zone B Business Overlay Ground Water/Zone II Year Constructed 1964 Lot Size 5.03 Property Use: Commercial— Storage Business - U-Haul Setbacks: Front:Yard 20 Cert of Occupancy Issued: Yes Side Yard . 0 Date August 10, 2000 Permit 47965 Rear Yard 0 Open Permits: Issued - see list Code Violations_ History of violations documented in file concerning work without permits, failure to maintain fire protection system & smoke alarms, electrical, plumbing, sign codes, improper storage of haz mat. Hyannis FD report on file. No additional violations noted in 2017. Review of file found issuedlexpired permits—no inspections. Work commenced on showroom & second floor without permits, approval or zoning relief. Zoning Violations: Unable to locate sign permits for wall signs. History of utilizing un-permitted A-frame or portable signs. Management advised of violation during 2016 inspection—sign removed. 2016 -Found second floor to have apartment/s under renovation. No permits for use or work. Advised Manager\ to secure proper approval and.permits for intended use. Mixed use proposal may impact sprinkler requirement. Referred matter to Chief Local Inspector.No permit application for intended work has been submitted as of 2/10/17. Reviewed by Title Date: Robin C. Anderson Chief Zoning Officer 2/10/2017 1 TOWNy.� `�..�.-�TG�7.f+��t�A���`'_'.��J_,�,-:_. vII �'LL`11711"1�1J8 CERTIFICATE OF OCCUPANCY- STORAGE -ROOMS PARCEL ID 293 046 GEOBASS- iD ADDRESS 594 BEARSE-S WAY . :-_:: -, :;_-_•:. ;_. ; :;_ > ' . PHONE HYANN I S ZIP - LOT 6 LC271 `_:.yOT SIZE BLOCK _�,� : DBA DISTRICT CT FAY PERMIT 47965 DESCRIPTION. ---:_-_: _::=` PERMIT TYPE BC00 TITLE CERTIFICATE: OF ;OCPANCY CONTRACTORS. ... of�e It ARCHITECTS. - :- _ - Depa_rtment a �, S: -- - - `Environmental Sew. TOTAL FEES: BOND . -- _ __ - - r=--= - ,•:= :�::- ,:•. , CONSTRUCTION COSTS $-00 756 CERTIFICATE OF OCCUPANCY:-.= _.____ MVATH-.P + E� grAB 'NAM e ' UILD Ivis DATE ISSUED 08/10/2000 :HXPIRAIQN..=:IIAT = - -. .. ._._. i a� .11Pana1'. '5 La0gadmas.trarnowad '"'j,�p�i ;: ;x• Address Pamela ttcenasa Pernds ;Project Revkw hspec0ans COOS7gnoR 'G�k Personnel Reports.'W� Sdredsk i ..� Street: . woase a Prb I a ar l Prajiertp CharactensUcs' ssa_ ACdress r594 BEARSE S WAY FiYANtdiS I ropetry Use New Address ' Otimer. TfltRTEEN SAC SELF�STQRAGE CARP LWAfea 2191O7r'{ �"' Perrnfits 21ci71W at+r a IxParceilD 29U46 3 YeatBllat � P_,6T78•f.�Pi� ��� >s �,�' a ��'' 6cok Pala Gt6'A�o2s��"� j Electrical P No Q Qti039 Ta1s-,n1} <: f� Closed u,aza» ;, i 8-,S•,770 DPQ� _SUM PareN Perr r'�A�s Aye I Inactive Pen11i4in4o� �.. rf "� '� Worjc QesartpUon 'REPLACE LGKnNG Wlnl _.. E-cols-msood + d�Tiva �anma�A - .<�- oma� .ErffecvEFFCIEwr " ,� Eeetral wm no1 FWURES E —! G-201408751 r ,,y i s i ���s� Staia�ZrRPhonalr .I —_ P-2014-08250 TNPtTFEJt SAC SE131250E HU5 WAVE�OENU AZ SSOtf �i } '� G-201405554 �ApDbuath tseb ale 0s' RFI �uU�/tum to �Espas0a Date x S.z013-Oseso ' a ^'�°a" g Q y8 ` �: ,�° �+r u, it 1 --- v ...�C-2i1301356 IyAP0esl fleme., F�,Addrass CdY„✓ ?"� �r Stale �t�P�y. Phone}io i RtSE EIlGriEERiNG'1341 ELtdNlOGDkV GRANSTON RIB 02910 Lt bt r v i _0 Ls0 Atl�pnad"it;pa«a x x �,ShowRjlTYpas� IiP' �oa Cimty6e, r I� � � a ��. s' r � I Contractor Info A xra y L' Gommens .._. r' K v�'Ytn Y^.rr�M` C2-. IIS Arailaak COMredas,y �ss. yx lnspecUanCerG6cffie f lypatiaaaFl3t3r� sr <att}3 x f x r Asai9nea CaMettors itj Assa}n s' __________ _........_ License Type Ucensea umuf (71ilELSCN) MSEL �.... 4 i "` °,. i ► RISE EHGINEERRIG A16S57 7111Pt0,' Edit Yade: IL CS113i�DAaNlWefd � . '.: oFtHElowti Town of Barnstable o� r ST,,B ; Building Department 9Q ma 200 Main Street pie i639. �0 Tfa,MA<" Tel. (508)862-4038 .. PLUMBING PERMIT Date: 7/11/2016 Fee: $105.00 Construction Cost: $0.00 Permit No:- P-16-778 Building Location: 594 BEARSE'S WAY, HYANNIS F Appllnt Name _ Brian A Lafleur Type of Occupancy: Commercial =.V ;�£ Type of Work Plumbing THIRTEEN SAC SELF-STORAGE CORP 1250 E fllI1SSOURI AVE PHOENIX AZ 85014 . _: Owner Name _ Address City { State Zip Phone Work Description: on first floor a drinking fountain a kitchen sink a lav and a service/map sink His license is current system did not p)ck 1t up. r Contractor Name Address gCiy x IStateZp rPtioneLiaType �Lic No Lic.E� Brian A Lafleur 2587 GAR HWY $WA NSEA x MA 20277773349 Journeyman 33062 5/1/2016 17 ' Plumber __. The recipient of this permit accepts this permit on thecondltlon ttha�t as owner or as agent of the owner, he/she agrees to comply with all Building &Zoning Ordinances of the Town of Barnstable&the State Statutes of the-State of Massachusetts regarding the use, occupancy&type of building to be constructed, added to, or altered. Additional conditions listed below. ., All permits approved are subject to inspections performed by1aepresentative of this office. Requests for inspections must be made at least 48 hours in advance. , x r 7/11/2016 Date Building Official ,. M. \ .. . ..... o. ... : ?a�. :.... •.. .+r.. -\2,..,.,>\\..\.... < .::, ....,> :....,. \ ,. FxT,a, \., Ca 5Q8 ,862-4.038.For Iasi ection °F`Heroyy°� Town of Barnstable a�xrrsr"M ? Building Department �A 163.9 A�0 200 Main Street Tel.(508)862-4038 TED:MA< ELECTRICAL PERMIT ' Date: 8/24/2016 Fee: $150.00 Construction Cost: $8,000.00 Permit No: E-16-1285 Building Location: 594 BEARSE'S WAY,�HYANNIS ,- ., Applicant Name: James Long 14 m Purpose of Building: Commercial Type of Work: Electrical -Add/Alter THIRTEEN SAC SELF-STORAGE CORP _�1250 E MISSOURI AVE PHOENIX AZ 85014 (339)469-2964 Owner Name Address '4 City State Zip Phone ti Existing Service: 0.00 0 New Service: 0.00 0 0 Amps Volts ( Overhead Undergrourido.of Meters Amps Volts Overhead Underground No.of Meters I aim Description of Work to be Done: Showroom W ea Installation of additional lighting in the existing drop ceiling. Wiring of additional duplex receptacles. Replacement of existing ecepta�ces as necessary. Installation of new exhaust fans and wiring for the renovation of the existing bathrooms. 2nd floor apartment ;Repair/replacement<of receptacles as necessary, installation of new receptacles where necessary. Installation of GFCI outlets m A code. �� �u State Zip Phone Lic.Type DBA Contractor Company . Address Clty P yP Lic. No Lic. Exp James Long 519 AMERICAN LEGION HWY WESTPORT MA 027904100 (508)636- Master 12341 7/31/2016 STE 1 6263 Electrician Class A The recipient of this permit accepts this permit on the condition that,as owner or as agent of the owner,he/she agrees to comply with all Building&Zoning Ordinances of the Town of Barnstable&the State Statutes of the State of Massachusetts regarding the use,occupancy&type of building to be constructed,added to,or altered.Additional conditions listed below: All permits approved are subject to inspections performed by a representative of this office. Requests for inspections must be made at least 48 hours in advance. 8/24/2016 Electrical Inspector Date Utility Authorization No. w _ Town of Barnstable • Builds Post T,h�shCard SozThat rt i"s'U�sible€From,the�Street Appr,'oved,Plans M,ust�be Retamed�on,Job and;;,th�s Cartl Must be=Kept ng MAE& Posted Until l=inal,lnspection Has Been Made r `,` �` Permit ea Where.a,:Cert�ficate.'of.Occu anc ,is Re,wired,such Buldmgshall-N.ot'be Occupied until a Final Inspect�gn has bee rnatle Permit NO. B-16-1770 Applicant Name: Dean Marshall Approvals Date Issued: 08/22/2016 Current Use: Structure Permit Type: Alteration INTERIOR Work Only-Commercial Expiration Date: 02/22/2017 Foundation: Location: 594 I BEARSE'S WAY,HYANNIS Map/Lot: 293 046 Zoning District: B Sheathing:� z Owner on Record: THIRTEEN SAC SELF-STORAGE CORP Contractor Name: DEAN M MARSHALL Framing: 1 Address: 1250 E MISSOURI AVEy Contractor License CS-072660 2 PHOENIX,AZ 85014 EstPro�ect Cost: $40,000.00 Chimney: Description: Remodel of existing showroom and relocation;of`counters within Pe mit Fee: $464.00 M i sz, z Insulation: same. Renovation and updating of existing bathroomssto meet ADA i% Fee Paid: $464.00 specifications. Final: Date 8/22/2016 Remodel of existing showroom and relocation of counters j E � Project Review Req: g - and u datin tin`b'athroo for o" r Plumbing/Gas within same. Renovationp i meet ADA specifications. ��� - Rough Plumbing: Building Official Final Plumbing: This permit shall be deemed abandoned and invalid unless the work authorized by this permit is commenced within six months afkerissuance. Rough Gas: All work authorized by this permit shall conform to the approved applicat!q, and the approved construction documents for which this permit has been granted. All construction,alterations and changes of use of any building and structures shal st l'be in compliance with the local zomngby lawsand codes. Final Gas: ; ' This permit shall be displayed in a location clearly visible from access reet or road and shall be maintained open for pubic impeetion for the entire duration of the work until the completion of the same. 1 Electrical � . The Certificate of Occupancy will not be issued until all applicable signatures by the Build g1an Fire ls;4r6ift areproded on this"permit. Service: Minimum of Five Call Inspections Required for All Construction Work. ` 1.Foundation or Footing ` Rough: 2.Sheathing Inspection 3.All Fireplaces must be inspected at the throat level before firest flue lining is installed Final: 4.Wiring&Plumbing Inspections to be completed prior to Frame Inspection 5.Prior to Covering Structural Members(Frame Inspection) Low Voltage Rough: 6.Insulation 7.Final Inspection before Occupancy Low Voltage Final: Where applicable,separate permits are required for Electrical,Plumbing,and Mechanical Installations. Health Work shall not proceed until the Inspector has approved the various stages of construction. Final: "Persons contracting with unregistered contractors do not have access to the guaranty fund"(as set forth in MGL c.142A). Fire Department Building plans are to be available on site Final: All Permit Cards are the property of the APPLICANT-ISSUED RECIPIENT °Ft"Er�yo� Town of Barnstable a�►srns�E Building Department, artment, t6 ;q �0 200 Main Street Tel.(508)862-4038 �FD.MA't 6 a, ELECTRICAL PERMIT w Date: 3/31/2015 Fee: $180.00 Construction Cost: $0.00 Permit No: E-2015-01675 Building Location: 594 BEARSE'S WAY,'HYANNIS Applicant Name: - LONG, JAMES J Purpose of Building: Commercial ,; Type of Work: Electrical -Add/Alter 311 THIRTEEN SAC SELF-STORAGE CORP 250 E MISSOURI AVE PHOENIX AZ 85014 Owner Name ,YAddress City State Zip Phone Existing Service: '; ��" New Service: Amps Volts Overhead Undergrourido.of Meters Amps Volts Overhead Underground No.of Meters Description of Work to be Done: REPAIR OFEMERGENCY LIGTS&EXIT SIGNS THROUGHOUT FACILITY ADDING A FEW EXTRE AT FD REQUEST; MAINTANANCE& REPAIR OF EXIT State " f Zip Phone Lic.Type Lic. No Lic.Exp DBA Contractor Company Address Clty'; A JAMES J LONG 519 AMERICA LEGION HWY WESTPORTT MA� 02790 508-636- NULL NULL LONG,JAMES J STE 1 6263 The recipient of this permit accepts this permit on the condition that,as owner or as agent of the owner,he/she agrees to comply with all Building&Zoning Ordinances of the Town of Barnstable&the State Statutes of the State of Massachusetts regarding the use,occupancy&type of building to be constructed,added to,or altered.Additional conditions listed below: All permits approved are subject to inspections performed by a representative of this office. Requests for inspections must be made at least 48 hours in advance. . 3/31/2015 Electrical Inspector Date Utility Authorization No. °f,HEI Town of Barnstable ► �� = Building Department �A fb7.9 A�0 200 Main Street Tel.(508)862-4038. ELECTRICAL PERMIT Date: 3/25/2015 Fee: $60.00 Construction Cost: $0.00 Permit No: E-2015-61500 IN Building Location: 594 BEARSE`S WAY, HYANNIS Applicant Name: SILVA ELECTRIC.IN, §- t { ' k Purpose of Building: Type of Work: Electical -Minor THIRTEEN SAC SELF-STORAGE CORP1250 E MISSOURI AVE PHOENIX AZ 85014 Owner NameAddress City State Zip Phone b Existing Service: ;� New Service: Amps Volts Overhead -Undergrourido.of Meters Amps Volts Overhead Underground No.of Meters Description of Work to be Done: MISC. REPAI RS.,AQD1 EXIT SIGN AND EMERGENCY LIGHTS INSTALL SWITCH FOR COMPRESSOR Contractor Company Address city� State Zip Phone Lic.Type Lic. No Lic. Exp DBA SILVA ELECTRIC 30 BOURNE HAY ROAD 'SANDWICHIA '--,' �Mi4 ;02563 (508)428- JNEL 21649 7/31/2013 SILVA ..,. J�gS a 9082 30 BOURNE HAY.ROAD xM. SAND------`.> MA - F 02563 (508)428- MSEL 9147 7/31/2013 9082 The recipient of this permit accepts this permit on the condition that,as owner or as agent of the owner,he/she agrees to comply with all Building&Zoning Ordinances of the Town of Barnstable&the State Statutes of the State of Massachusetts regarding the use,occupancy&type of building to be constructed,added to,or altered.Additional conditions listed below: All permits approved are subject to inspections performed by a representative of this office. Requests for inspections must be made at least 48 hours in advance. 3/25/2015 Electrical Inspector Date Utility Authorization No. 4 . . Anderson, Robin To: Cassie Phelps Subject: RE: Zoning Hi Cassie, Our Business (B) zone is our most liberal district. The U Haul use would fall under the clause that calls out " . . .Any other use of similar nature" under A 8; similar is .as it relates to 1 & 2 under the same section (Chapter 240 Section 21 A) . The front yard set back in the B zone is 201 . I don't have a site plan that specifies what the exact measurement is but I would be very surprised if it didn't meet the 20' setback as there is parking along the front of the building. The B zone has no side or rear setbacks- and as this project was constructed before the site plan review was adopted I do have limited information. Zoning relief should not have necessary for the original proposal. The parking is recognized as an existing condition (previously approved by a former Commissioner.- The site has organized parking in front of the building for customers and employees. Only if there is a proposal to change the site would additional review and recalculation of parking needs be required and the same would be true of the landscaping provisions. `I hope this answers your questions. Please let me know if .you more information. Robin Robin.C. Anderson Zoning Enforcement Officer 200 Main Street Hyannis, MA 02601 508-862-4027 ---r-Original Message----- From: Cassie Phelps [mailto:cassie.phelps@globalzoning.comI Sent: Sunday, February 19, 2017 11:35 AM To: Anderson, Robin Subject` RE: Zoning Hi Ro in b. , RE':,'594 Bearses Way- Uhaul Moving and Storage Thank.youu for the zoning letter on the above property. I ran into a few additional questions after reviewing the zoning code: 1.) It appears that Self Storage and Moving Truck Rental uses are not permitted in the B District. Did the property receive a use permit/variance? Or is the existing use legal nonconforming? 2) It appears the property does not comply with the front setback and landscaping/buffer requirements. Did this receive a variance or is this legal nonconforming? 3) I`t appears that parking requirements would be "determined by the building commissioner" (section 240-56) . Do you have any record of the parking that was approved/required by the building commissioner? Thank you! Cassie ---'--Original Message----- .. 1 I From: Anderson, Robin [mailto:Robin.Anderson@town.barnstable.ma.us] Sent: . Friday, February 10, 2017 3 :13 PM To:. Cassie Phelps <cassie.phelps@globalzoning.com> Subject: FW: Zoning Please find the Cert of Zoning Compliance attached. Let me know if you have any questions. Robin Robin C. Anderson Zom rig Enforcement Officer 200 ,Main Street Hyannis, MA 02601 508.-862-4027 Certificate of Zoning Compliance.pdf>> 2 I Town of Barnstable �1HE Tn. Regulatory Services "+V Richard V. Scali,Director ,, „CAB Building Division BARNSTABLE 9 MA3.S. A :aa��reM[ miR uec a*•sEgvsi a� P s6;9• ♦0 Paul Roma, 1639,2014 ArFD1A°rA Building Commissioner 200 Main Street, Hyannis, MA 02601 www.town.barnstable.ma.us Town of Barnstable Certificate of Zoning Compliance Certificate 2017-02 Map 293 Record Owner: Parcel 046 Address 594 Bearse's Way Thirteen SAC Self-Storage Corp. Village Hyannis 1250 E Missouri Ave. Phoenix, AZ 85014 Zone B Business Overlay Ground Water/Zone II Year Constructed- 1964 Lot Size 5.03 Property Use: Commercial— Storage Business - U-Haul Setbacks: Front Yard 20 Cert of Occupancy Issued: Yes Side Yard 0 Date August 10, 2000 Permit 47965 Rear Yard 0 Open Permits: Issued- see list Code Violations_ History of violations documented in file concerning work without permits, failure to maintain fire protection system & smoke alarms, electrical,plumbing, sign codes, improper storage of haz mat. Hyannis FD report on file. No additional violations noted in 2017. Review of file found issued/expired permits-no inspections. Work commenced on showroom & second floor without permits, approval or zoning relief. Zoning Violations: Unable to locate sign permits for wall signs. History of utilizing un-permitted A-frame or portable signs. Management advised of violation during 2016 inspection—sign removed. 2016 =Found second floor to have apartment/s under renovation. No permits for use or work. Advised.Manager to secure proper approval and permits for intended use. Mixed use proposal may impact sprinkler requirement. Referred matter to Chief Local Inspector. No permit application for intended work has been submitted as of 2/10/1.7 : Reviewed by Title Date: Robin C. Anderson Chief Zoning Officer 2/10/2017 ",Global Zoning 8205 NW 6911 Street Oklahoma City, OK 73132 405-792-2075 CD Cassie.phelps@globalzoning.com Global Zoning www.globalzoning.com January 13,2017 Barnstable Building Department Attn:Robin 200 Main Street Hyannis,MA 02601 Dear Zoning, ` RE: Zoning Verification Letter-594 Bearses Way, Hyannis (Barnstable), MA Please find this to be a request for a zoning verification letter on the above stated property.We are researching these matters for a zoning compliance report. Please incorporate the answers to the following questions'in a letter on letterhead. • What is the current zone of the property?Are there any overlay districts? • Did the property receive any variances,PD's,conditional or special permits issued or require site plan approval?If so,can you provide a copy? • Are there any active outstanding building,zoning or fire violations on file? • Was a certificate of occupancy issued and if so,may we obtain a copy of it? • Are there any current or pending road projects that will require additional right of way from this property? Please email the letter and documents to cassie.phelps@globalzoning.com if possible. If you cannot E-mail, please return the letter to: Global Zoning C) n 8205 NW 69th Street Oklahoma City,OK 73132 5 w Warm rVrda a Cassie t _ f TOWN OF BARNSTABL U-Haul of Hyannis 594 Bearses Way,Hyannis MA 02601. Store#872067 Apartment Diagram Prelimary Drawing(not for construction) as of 26 October 2016 — -- Existing Window Existing Windows Window 5'x 2'8" Window F- 6'10" Existing 7'9"x 2'11" 4-1/2°off floor Existing Bathroom Bedroom 4-1/2"off floor u s" Laundry - 5'10" These windows will be 4 12'11" These windows will be 12'replaced to residential m; m replaced to residential- x n 18'1"operable windows to operable windows to o w v 0 meet MA code for 2nd meet MA code for 2nd ro °D o0 means of egress per Bedroom Qoor § means of egress per Deputy Chief Melanson "oor♦♦ o Deputy Chief Melanson Bathroom t 4- 4'6 —t—► Doo * N 5191. 6' o Hallway 4'9a. o JO 0 These windows will Doo _ tj Doo Door remain as-is I urnac Open Kitchen 8 Plan 19,11" ClosetDoo a 10'2" 25'7" Bedroom Office 11'5":: Living Room Take out storage Door unit and relocate rider stairs . Doo . ° Hallway 5'7" °o Renovation of stairs to meet all MA fi codes for/mns a ress New: Emergency access \ g door for storage area ! 2nd floor, ;;;,;r,,;,;,; rn-. New door to outside New: Emergency access II '' II � Wit door for storage area l i I U LJ111 i � � �' � i 101 �_t!�!�!��t!�!�_t �_i!�!�!�!�_i�J' lst floor .Note: this design was discussed with Deputy Chief Melanson on 25 October 2016 at 9:00 a.m.:with on on-site with James J.Long Inc,CANCO,and Karen Rodericks,U-Haul AFM present Note: the sprinkler system will be re-configured and designed by Conco(per discussion on-site with Rick and Tom from Conco)to meet MA code and approved by Chief Melanson.. Note: we will also work with NESS,who has the annual maintenance contract for the fire alarm to add all the necessary devices(CO2/smokes;horn strobes)to the existing fire alarm system 5R� ��J r Town of Barnstable 1,i11C11I1 .,. oThatit-as:>U�sibleFrom'the5treet A r:,oved Plans Mustbe,Reta�npd,on Jobandthis Card Must be;Kept .errrrs,rvsJc Post ThisCard_S a; pp r Fv M" Posted Until Final InspectionHas BeeMade _ �� ;, ;- .N sbaa ,., �- ; .„ w: Permit iWhere a Gertificate,of Occu ancy is Required,such Buildmg shall Notbe Occupiedf,until a F�RaI Inspection has been made Permit No. B-16-1770 Applicant Name: Dean Marshall Map/Lot: 293-046 Date Issued: 08/22/2016 Current Use: Zoning District: B Permit Type: Alteration INTERIOR Work Only-Commercial Expiration Date: 02/22/2017 Contractor Name: DEAN M MARSHALL Location:, 594BEARSE'S WAY,HYANNIS _ Est Proje�ct Cost: $40,000.00 Contractor License: CS-072660 Owner on Record: THIRTEEN SAC SELF-STORAGE CORP %g Perrn Fee $464.00 Address: 1250 E MISSOURI AVE `f Fee Paid $464.00 PHOENIX AZ 85014 Date a .. k �8/22/2016 Description: Remodel of existing showroom and relocation of counters within same. Renovation and.,updatmg of existing bathrooms % r to meet ADA specifications. f ..,.. Project Review Req : Remodel of existing showroom and Selo anon of counters within same Renovation and updating of existing bathrooms to meet ADA,specifications Ilk F Building Official a This permit shall be deemed abandoned and invalid unless the work authozrized by this'permif-is commenced wrthm�x mon#hsafter issuance. All work authorized by this permit shall conform to the approved application and the,approved construction documents fo wh;ich this permit has been granted. All construction,alterations and changes of use of any building and structures shall be in compliance with the local zoning' y taws and codes. This permit shall be displayed in a location clearly visible from access street or.roadand shall be maintained open for public mspection for the entire duration of the work until the completion of the same. ( c j The Certificate of Occupancy will not be issued until all applicable signatures by the Building and Fire Officials are provided onthis permit. Minimum of Five Call Inspections Required for All Construction Work: , 1.Foundation or Footing K � 2.Sheathing Inspection 3.All Fireplaces must be inspected at the throat level before firest flue Immg is installed 4.Wiring&Plumbing Inspections to be completed prior to Frame Inspection o 5.Prior to Covering Structural Members(Frame Inspection) ' 3"' "' "' """ .•k• ..,,•, 6.Insulation 7.Final Inspection before Occupancy Where applicable,separate permits are required for Electrical,Plumbing,and Mechanical Installations. Work shall not proceed until the Inspector has approved the various stages of construction. "Persons contracting with unregistered contractors do not have access to the guaranty fund (as set forth in MGL c.142A). Building plans are to be available on site All Permit Cards are the property of the APPLICANT-ISSUED RECIPIENT s � - � A G � 1 \ _ � �c� J� � � � � �� OVERAGE: ich meets the requirements of MGL Ch.142. YES NO Q KING.THE APPROPRIATE BOX BELOW UAITY ® BOND lave the insurance coverage required by Chapter 142 of the ication waives this requirement. _ CHECK ONE ONLY: OWNER ® AGENT - regarding this application are•true and accurate to the best of my knowledge or this application will be in compliance with all Pertinent provision of the SE# SIGNATURE PARTNERSHIP# LLCO#L= 2 TEL WSA WILLIAM STARCK ARCHITECTS, INC. August 22, 2016 Jeff Lauzon, Chief Building Inspector Building Division 200 Main Street Hyannis, MA. 02601 Re: U-Haul 594 Bearses Ways ' Hyannis, MA Please accept the following existing building narrative for the proposed interior renovation project - at the above referenced location. Please note that the renovation project is contained within the mercantile portion of the building. Existing Building Narrative Section 1 Existing Building Description Existing building use group: (S-1) Moderate Hazard Storage/(M) Mercantile (incidental use group) Existing total ground floor area of the building: approximately 24,852 S.F. Existing total area, all floors: approximately 25,852 S.F. Existing building height: 18'-0"+/- Existing number of floors above grade: one (Previous use was an owner/manager apartment. Currently this space is unoccupied and used as storage) Existing number of floors below grade: Zero Occupancy(s)within the building: Mercantile Hazardous materials or processes in the building: N/A Storage over 12 ft: none Section 2 Classification of Work Alteration —Level 2 (404 IEBC 2009) The scope of work for this project includes the construction of two (2) interior offices and two(2) restrooms within existing space. All other work is limited to replacement of finishes. There is to be no impact to structural framing members or alterations to the fire protection, mechanical or plumbing systems. Section 3 Chapter 7 Alterations—Level 2 Building Elements and Materials (703 IEBC 2009) All new interior wall, ceiling, floor and trim finishes shall comply with Chapter 8 of the International Building Code. Fire Protection (704 IEBC 2009) The existing sprinkler system will remain in place with minor modifications; one existing sprinkler head will be removed and replaced approximate three feet from its current location. The licensed fire suppression company will apply for separate sprinkler permit before any work is done. 126 Cove Street www.StarckArchitects.com 10 Dorrance Street,Ste.700 Fall River,MA 02720 Providence,RI 02903 tel (508)679-5733 tel (401)519-3647 fax(508)672-8556 Page 1 of 2 fax(401)519-3601 i WSA WILLIAM STARCK ARCHITECTS. INC. Means of Egress (705 IEBC 2009) Occupant Load Retail Area 2,087 sf/ 30 = 66 occupants Egress Requirements Doors— Required 63 occupants x 0.2" = 14" Existing = 320" First Floor Exits— Required (1 accessible) 2 Existing 3 (3 accessible) Structural (707 IEBC 2009) There are no alterations to the existing structural system under this permit application. Electrical (708 IEBC 20091 All new electrical equipment and wiring installed under this permit application shall be in full compliance with the National Electrical Code (NFPA 70). Mechanical (709 IEBC 2009) y There are no alterations to the existing mechanical system under this permit application. Plumbing (710 IEBC 2009) Two (2) new AAB compliant�estrooms and an employee breakroom sink will be added. The licensed plumbing contractor will apply for separate permit as needed. End of Narrative We hope this report, in combination with the construction drawings, sufficiently addresses all of .your office's concerns regarding this project; however, if you have any comments or questions, please do not hesitate to contact us. Sincerely T WILLIA l4 ECTS, INC. C,P O c� 100$ RodA„R.A. Vice cr,usEr,, . y Chaper 34 Review_H annisUhaul_Revised y°F www.StarckArchitects.com Page 2 of 2 L ^'/�.�� � C) 1 � �-, � � � --� , � .-i--� � � , ��� � � � ���� � s -� � � � � �� - � � � o Town of Barnstable �t Regulatory Services Richard V. Scali,Director .ARN,SfABM ; Building Division BARNSTABLE �. o � n; i639 .• Thomas Perry, CBO 639-2014 p'E01i"°�A Building Commissioner �Dg 200 Main Street, Hyannis, MA 02601 www.town.barnstable.ma.us Office: 508-862-4038 Fax: 508-790-6230 Jan 1 2014, Dan Marini 25 Richmond st. Weymouth MA, 02188 Dear Mr Marini, Ouroffice has not received the requested plans showing the corrected engineering for permit application 201301950. "Installation of an awning/canopy". Therefore your application must be denied. If you have any questions feel free to contact me at 508-862-4035. Sinc ely, Patrick Franey Local inspector � 3r PERMIT PAYMENT RECEIPT OF BARNSTABLE�' � BUILDING DEPPARTMENT200 MAIN ` HYANNIS,_ MA 0261 ; }T DATE: 11712/?3 ` TIME: 09:00 ------------------TOTA LS-- - ,Y- ---- PERMIT $ PAID 100.00 AMT,TENDERED: 100.00 AMT APPLIED: 100.00 ' 3 CHANGE: .00,. APPLICATION NUMBER: 201301950 • PAYMENT METH: CHECK PAYMENT REF: 3498 - TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION //yy `1 Vl Map, `'l(5 Parcel 04& Application /' Health:Division / Date Issued Conservation Division Application Fee Planning Dept. Permit Fee Date Definitive Plan Approved by Planning Board Historic - OKH Preservation/ Hyannis Project Street Address, S qL1 8641665 " Village ' 0161VNI-5 - Q � Owner Address 7�29 Telephone_, 0 - c5 q 7 Permit-Request- OF U Square feet: 1 st floor: existing proposed floor: existing proposed Total new Zoning District Flood Plain Groun ater Overlay Project Valuation •___-Construction Typ . _ Lot Size Grandfathere ❑Yes ❑ No If yes, attach supporting documentation. Dwelling Type: Single Family ❑ Two F ❑ Iti-Family (# units) Age of Existing Structure Historic ouse: ❑Yes ❑ No On Old King's Highway: ❑Yes ❑ No Basement Type: ❑ Full ❑ Crawl ❑Wak 0ut Other Basement Finishe rea (sq.ft.) Basement Unfinished Area (sq.ft) Number of Bat : F II: existing ew Half: existing new, Number of Be rooms: existin new Total Room C unt (not inclu baths): isting new First FI 0 Room Count Heat Type an Fuel: ❑ Gas ❑ 'I Electric ❑ Other Central Air: ❑ es ❑ No Firepla Existing New Existing wood/coal stove:'_41 Yes ❑ No Detached garage: ❑ existing ❑ new size ool: ❑ existing ❑ new size _ Barn ❑existing ❑fiw size_ Attached garage: ❑ existing ❑ new size Shed: ❑ existing ❑ new size _ Other: Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑Yes ❑ No -If yes;gsite plan review# Current Use Proposed Use APPLICANT INFORMATION -- -" (BUILDER OR HOMEOWNER) 7$`,72M 7�,9- -,,Na -Telephone�11� u"I�AV + V�' Telephone-Nurriber� (11 d 9' Address_ S J (LkV,W0VID 51 '- - ` -License#4��S • 00 + �V� �: j Home Improvement Contractor# 7 Z °! L-LL Worker's Compensation# ALL CONSTRUCTION DEBRIS.RESULTING FROM THIS PROJECT WILL BE TAKEN TO c SIGNATURE DATE" . �` ..... t FOR OFFICIAL USE ONLY APPLICATION# yr • �--. _. DATE ISSUED MAP/PARCEL NO. � 5 h ADDRESS VILLAGE t OWNER j DATE OF INSPECTION: ,.,-FOUNDATION, FRAME z INSULATION - � FIREPLACE ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH _ FINAL GAS: ROUGH FINAL' ; FINAL BUILDING ;F DATE CLOSED OUT ASSOCIATION PLAN NO. E � Printed by:Pete Otio Wednesday,March 27,2013 3:00:28 PM Title: Page 1 of 1 Town of Barnstable Regulatory Services Thomas F.Geller,Director Building Division Tom Perry,Building Commissioner 200 Main Street,Hyannis,MA 02601 www.towabatustable ma os Office: 508-8624038 Fax: 509-790-6230 Property Owner Must Complete and Sign This Section If Using A Builder AdL &I &,A 3S l/���G ,as Owner of the subject property hereby authorize /(r —TA-1 B-1' to act on my behalf, in all matters relative to work authorized by this building permit 21 &Niges WXle / a-124� � (Address of Job) **Pool fences and alarms are the responsibility of the applicant. Pools are not to be filled or utilized before fence is installed d all final inspections are performed and accepted. ignature.of Owner Signature of Applicant Print Name Print Name h7 Date•( Q:.rowMs:owrarxP a-nsstor>poois 0012 The Commonwealth of Massachusetts Department of Industrial Accidents - Office of Investigations 600 Washington Street �• Boston, MA 02111 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): ��9ylu� /' ►/9A/' (%ti`� 0f C4—Z,,/C . L Address: Z 6 n-vA t'LJ S i t,4, City/State/Zip: W(l ' /hou►N OZ1EV Phone#: 73)- 3 3) - 3(Yo0 Are you an employer?Check the appropriate box: 1.Q I am a employer with 60 4. ❑ I am a general contractor and I Type of project(required): * have hired the sub-contractors 6. [New construction employees(full and/or part-time). , 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g, ❑ Demolition workingfor me in an capacity. employees and have workers' y p �'• 9. ❑ Building addition [No workers' comp. insurance comp. insurance.: required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their I I.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.9-Other (AAX>P1 comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. /� Insurance Company Name: ZUA (,H ` A(q 1(1 Z CAN 6rto o Policy#or Self-ins.Lic.#: 6/\)OM�ZL) Expiration Date: 5� Z3 011 Job Site Address: �r /9 dbilSf,S �Jl y City/State/Zip: J-f�►ANN LS. UZ(,O) Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certi der a pai and p [ties ofperjury that the information provided above is true and correct Signature: Date Z Phone#: Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: i `♦C-® CERTIFICATE OF LIABILITY INS 25/201/DD/YYY1� INSURANCE 6/25/2013 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements. PRODUCER CONT CT NAME: Eastern Insurance Group LLC-Main PHONE - aC Ne 233 West Central Street 7700 E•MA0 Natick MA 01760 ADDREss: i INSURE S AFFORDING COVERAGE NAIC lI INSURER A: C a INSURED 161536 INSURER B:Ev Taylor Made Contracting LLC INSURERC:B erkley.Assurance Company 25 Harvard Street INSURER D Z -Amen Weymouth MA 02188 nG[Qup INSURER E: INSURER F: - COVERAGES CERTIFICATE NUMBER:1921301759 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IN SR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSR WVO POLICY NUMBER MM/DDNYYYI (MMIDDNyyyl LIMITS C GENERAL LIABILITY Renewal of VUMA0001861 /20/2013 /20/2014 EACH OCCURRENCE $1,000,000 X COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED PREMISES(Ea occurrence) $100,000 CLAIMS-MADE X-1 OCCUR MED EXP(Any one person) $5,000 PERSONAL&ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $2,000,000 POLICY X PRO- ircT LOC $ A AUTOMOBILE LIABILITY BDHQKM /23/2013 /23/2014 BIKED 1,000 000 ANY AUTO - BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS X AUTOS BODILY INJURY(Per accident) $ Ix HIRED AUTOS X NON-OWNED PROPERTY DAMAGE AUTOS Peracddent $ $ B X UMBRELLA UAB N OCCUR Renewal of XONJ445112 - 10/2013 /20/2014 EACH OCCURRENCE $1,000,000 EXCESS LIAB CLAIMS-MADE FAGGREGATE $1,000,000 DED X RETENTION$0 D WORKERS COMPENSATION N000524 /23/2013 /23/2014 X $ WC STATU- OTH- AND EMPLOYERS'LIABILITY Y/N ' ANY PROPRIETOR/PARTNER/EXECUTWE - E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? N❑ N I A (Mandatory in NH) EL.DISEASE-EA EMPLOYE $1,000,000 If yes,describe under . DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remarks Schedule,if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZE REPRESENTATIVE ©1988-2010 ACORD CORPORATION. All rights reserved. A/�AD/1 9C/fA�A/ACl TI.,. A#�^OII www...ww.i Iwww w.�.....w;..�...,..�-1-..i A/�ADr% t' t i `P�;��ciuoracueull�c�G�ll{rssac%rrselti. { Office of Consumer Affairs&Bus�dess Regulation n o. ME iMPROVEMENT CONTRACTOR Type: { E-egistration 172398 expiration , 6/21/2014- LLC TAYLOR MADE CONTRACTING LLC. MICHAEL TAYLOR A* , " ' ! 25HARVARD ST WEYMOUTH,MA 02188 Undersecretary { 1 Mass actsusetts-tDe}sartment.of Public Safety 1 ? "Boar of Building Re-guleNons and Standards Construction Supervisor ( License- CS-095199 4� DAYIEL P MARM 25 RICIEVIOND ST t..,- Wevmouth Na 02188 r rf \ Expiration - Cornaussloner 05/04/2014 i s Taylor Made Contracting, LLC 25 Harvard Street Weymouth, MA 02188 Ph: 781-724-8727 Fax: 781-331-3060 04/01/13 Re: Daniel Marini 26 Richmond St Weymouth, MA 02188 To whom it may concern: I am writing this letter to confirm that Daniel Marini is an employee of Taylor Made Contracting. Daniel joined our team in January of 2011, and has worked with us as a project manager/carpenter in our remodeling/building division of Taylor Made Contracting. Sincerely, Michael F. Taylor, President Taylor Made Contracting, LLC r The Commonwealth of Massachusetts William Francis Galvin- Public Browse and Search Page 1 of 2 �. The Commonwealth of Massachusetts t, William Francis Galvin 3 Secretary of the Commonwealth,Corporations Division may : One Ashburton Place, 17th floor Boston,MA 02108-1512 Telephone:(617)727-9640 TAYLOR MADE CONTRACTING, LLC Summary Screen Help with this form ",Request�a�Certittcate The exact name of the Domestic Limited Liability Company(LLC): TAYLOR MADE CONTRACTING,LLC Entity Type: Domestic Limited Liabili , Company(LLC) Identification Number: 000891694 Date of Organization in Massachusetts: 03/24/2005 Date of Revival: 03/03/2011 Date of Dissolution: 04/30/2009 The location of its principal office: No. and Street: 25 HARVARD STREET City or Town: WEYMOUTH State:MA Zip: 02188 Country: USA If the business entity is organized wholly to do business outside Massachusetts,the location of that office: No. and Street: City or Town: State: Zip: Country: The name and address of the Resident Agent: Name: MICHAEL F. TAYLOR No. and Street: 25 HARVARD STREET City or Town: WEYMOUTH State:MA Zip: 02188 Country: USA The name and business address of each manager: Title Individual Name Address (no PO Box) First,Middle,Last,Suffix Address,City or Town,State,Zip Code The name and business address of the person in addition to the manager,who is authorized to execute documents to be filed with the Corporations Division. Title Individual Name Address (no PO Box) First,Middle,Last,Suffix Address,City or Town,State,Zip Code SOC SIGNATORY MICHAEL F.TAYLOR 25 HARVARD STREET WEYMOUTH,MA 02188 USA The name and business address of the person(s)authorized to execute,acknowledge,deliver and record any recordable instrument purporting to affect an interest in real property Title Individual Name Address (no PO Box) http://corp.sec.state.ma.us/corp/corpsearch/CorpSearchSummary.asp?ReadFromDB=True... 3/29/2013 - Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "171011 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division -Page 02/11/2010 *'SIGNS AND LIGHTING Emergency Light Broken or Not 0 527CMR 10.17 130 No.tes: 2nd floor 02/11/2010 * SIGNS AND LIGHTING Emergency Light Broken or Not 0 527CMR 10.17 130 Notes:Violation carried over from inspection on 02/11/2010 2nd floor 02/07/2012 * 1.06(2) Failure to maintain a fire protection 1 0 'Notes: Failure to maintain a fire protection system Provide fire alarm test (burglar) annually. 12/26/2013 * 9.07 (A)-(P) Failure to comply/general provisions 11 0 Notes: Failure to comply with the requirements of general provisions regarding tanks and containers. 1. NFPA-58 (2011) 7.2.3.1 FAILURE TO SECURE THE FILLING SITE, PUBLIC ACCESS TO AREAS WHERE LPG IS STORED AND TRANSFERRED SHALL BE PROHIBITED, EXCEPT WHERE NECESSARY FOR THE CONDUCT OF NORMAL BUSINESS. i 04/24/2014 1.03 (2) Report of violations to other code 1 0 Notes:Violation carried over from inspection on 04/13/2013 Violation carried over from inspection on 04/16/2012 ELECTRICAL ISSUES General Observations. There were numerous problems noted. Mr Souza from F & S Electric was in attendance during the inspection and made his own detailed list of issues. The comments below are based upon existing conditions, approval of repairs and/or the installation of new equipment is done under the authority of the Town of Barnstable Building Electrical Inspector William Amara. We will copy this inspection to him and review conditions with him. You should plan on communicating with him for approval beford beginning any corrective actions.. 1. Remove. and properly correct the wiring for the lights in the elevator equipment room. This lighting is powered from an extension cord that is plugged into a wall outlet in the climate controlled storage area. It then penetrates the wall into the elevator control room where it is hardwired into an electrical box. (1st cited 29-MAR-12) [CORRECTED 4/13/13] 2. The wiring in the elevator control room is surface mounted. Surface mounted wiring must be run in conduit or otherwise properly protected from damage. (1st cited 29-MAR-12) [CORRECTED 4/13/13] 3. Remove the extension cord that runs from the sprinkler control room, through a sprinkler piping opening in the exterior wall and out to the parking lot. * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 1 Hyannis Fire Department Inspection .Violations .by Occupancy Occupancy ID = 111710" 1710 U-HAUL 594 BEARSES- WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page Install proper exterior G.F.I. outlets if needed for vehicle charging and/or block warming in this area. , 4 . In the 1000?s storage area remove the extension cord plugged in near electrical panel D.-This cord runs out through and overhead door to the exterior. Install proper exterior G.F.I. outlets if needed for vehicle charging and/or block warming in this area. 5. Properly remove abandoned electrical wiring and conduit from numerous areas. 6. Repair the broken electrical equipment in the electrical room off of the main showroom. 7 . Properly repair and enclosed exposed electrical connections in numerous areas.. One example is the ceiling of the main showroom near the main entrance. WALL HYDRANT 1. The water supply was found shut-off to this device. Discussions with the sprinkler company indicate there may be leaks in the system. It shall be repaired and returned to service. The system shall be protected against freezing (in a code compliant manner) and shall remain on year round. (1st cited 29-MAR-12) 2. Properly secure and/or properly supervise with the fire alarm system the control valve in the sprinkler room. 3. Install bollards in front of the wall hydrant connection to prevent vehicles from being parked so as to obstruct fire department access to this equipment. 4 . Install reflective a sign ?fire dept. wall hydrant? at least 6 ,ft. over the connection on the building. The . sign shall be a minimum of 18? long by 6? tall with a white background and red letters. BUILDING CONSTRUCTION ISSUES The comments below are based upon existing conditions, approval of repairs and/or renovations are ,the authority of the Town of Barnstable Building Commissioner Thomas Perry. We will copy this inspection to him and review conditions with him. You should plan on providing his office with plans for approval before beginning any corrective actions. 1. The storage area located under the stairs leading to the apartment has an open ceiling area exposing the non-sprinkler protected void space above the ceiling in the climate control storage area. There is also exposed wood frame construction in the area. This must be properly enclosed with sheetrock or other approved materials. (1st cited 29-MAR-12) . 2. Repair holes .in the ceiling above the electrical panel in the 4000?s adjacent to the elevator lift: 3. Sheetrock all exposed wood frame construction in the elevator equipment * Denotes Violations Corrected or Variance Issued 11/16/2015. 16:04 Page 2 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "171011 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page_ room. 4. Hitch Bay area, properly seal up the numerous holes in the walls separating this area from the main show room. 5. In the break room sheetrock or otherwise properly cover the exposed rigid foam insulation on the wall in this room. 6. The apartment (discussion indicated the desire for the apartment to remain and be rehabilitated. As such the follow is required; a. Repair/replace the missing and collapsed ceiling tiles. b. The bedroom windows do not appear to be code complaint as emergency egress windows. .They must comply with the maximum allowable sill height from the , apartment floor and provide the minimum amount clear opened square inches required. C. The apartment and its interior staircase are not separated from the storage areas by proper construction. d. The apartment has a glass slider that allows access directly to the 2nd floor storage area'. In addition to providing no rated separation between the occupancies the floors of the apartment and the storage area are at different heights. The apparent combustible void space below the storage area is exposed when the slider is opened as the storage floor is approx. 6 inches higher that the apartment floor. This must be properly corrected. 04/24/2014 1.03 (2) Report of violations to other code 1 0 Notes:Violation carried over from inspection on 04/24/2014 Violation carried over from, inspection on 04/13/2013 Violation carried over from inspection on ,04/16/2012 ELECTRICAL ISSUES General Observations. There were numerous problems noted. Mr Souza from F & S Electric was in attendance during the inspection and made his own detailed list of issues. The comments below are based upon existing conditions, approval of repairs and/or the installation of new equipment 'is done under the authority of the Town of Barnstable Building Electrical Inspector William Amara. We will copy this inspection to him and review conditions with him. You should plan on communicating with him for approval before beginning any corrective actions. 1. Remove and properly correct the wiring for the lights in the elevator equipment room. This lighting is powered from an extension cord that is plugged into a wall outlet in the climate controlled storage area. It then penetrates the wall into the elevator control room where it is hardwired into an electrical . box. (1st cited 29-MAR-12) (CORRECTED 4/13/13] 2. The wiring in the elevator control room is surface mounted. Surface mounted wiring must be run in conduit or otherwise properly protected from damage. (1st • * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 3 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page cited 29-MAR-12) (CORRECTED 4/13/13] 3. Remove the extension cord that runs from the sprinkler control room, through a sprinkler piping opening in the exterior wall and out to the parking lot. Install proper exterior G.F.I. outlets if needed for vehicle charging and/or block warming in this area. 4 . In the 1000?s storage area remove the extension cord plugged in near electrical panel D. This cord runs out through and overhead door to the exterior. Install proper exterior G.F.I. outlets if needed for vehicle charging . and/or block warming in this area. 5. Properly remove abandoned electrical wiring and conduit from numerous areas. 6. Repair the broken electrical equipment in the electrical room off of the main showroom. 7 . Properly repair and enclosed exposed electrical connections in numerous areas. One example is the ceiling of the main showroom near the main entrance. WALL HYDRANT 1. The water supply was found shut-off to this device. Discussions with the sprinkler company indicate there may be leaks in the system. It shall be repaired and returned to service. The system shall be protected against freezing (in a code compliant manner) and shall remain on year round. (lst cited 29-MAR-12) 2. Properly secure and/or properly supervise with the fire alarm system the control-valve in the sprinkler room. 3. Install bollards in front of the wall hydrant connection to prevent vehicles from being parked so as to obstruct fire department access to this equipment. 4 .. Install reflective a sign ?fire dept. wall hydrant? at least 6 ft. over the connection on the building. The sign shall be a minimum of 18? long by 6? tall with a white background and red letters. BUILDING CONSTRUCTION ISSUES The comments below are based upon existing conditions, approval of repairs and/or renovations are the authority of the Town of Barnstable Building Commissioner Thomas Perry. We will copy this inspection to him and review conditions with him. You should plan on providing his office with plans for approval before beginning any corrective actions. 1. The storage area located under the stairs leading to the apartment has an open ceiling area exposing the non-sprinkler protected void space above the ceiling in the climate control storage area. There is also exposed wood frame construction in the area. This must be properly enclosed with sheetrock or other approved materials. (lst cited 29-MAR-12) . * Denotes Violations Corrected or Variance Issued Page 4 11/16/2015 16:04 Hyannis Fire Department Inspection Violations by. Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page 2. Repair holes in the ceiling above the electrical panel in the 4000?s adjacent to the elevator -lift. , 3. Sheetrock all exposed wood frame construction in the elevator equipment room. 4. Hitch Bay area, properly seal up the numerous holes in the walls separating this area from the main show room. 5. In the break room sheetrock or otherwise properly cover the exposed rigid foam insulation on the wall in this room. 1 6. The apartment (discussion indicated the desire for the apartment to remain and be rehabilitated. As such the follow is required; a. Repair/replace the missing and collapsed ceiling tiles. b. The bedroom windows do not appear to be code complaint as emergency egress windows. They must comply with the maximum allowable sill height from the apartment" floor. and provide the minimum amount clear opened square inches required. , C. The apartment and its interior staircase are not separated from the storage areas by proper construction. d. The apartment has a glass slider that allows access directly to the 2nd floor storage area. In addition to providing no rated separation between the occupancies the floors of the apartment and the storage area are at different heights. The apparent combustible void space below the storage area is exposed when the slider is opened ,as the storage floor is approx. 6 inches higher that the apartment floor. This must be .properly corrected. 04/24/2014 1.03(2) Report of violations to other code 1 0 Notes:Violation carried over from inspection on 12/05/2014 Violation carried over from inspection on 04/24/2014 Violation carried over from inspection on 04/13/2013 Violation carried over from inspection on 04/16/2012, ELECTRICAL ISSUES General Observations. There were numerous problems noted. Mr Souza from F & S Electric was in attendance during the inspection and made his own detailed list of issues. The comments below are based upon existing conditions, approval of repairs" and/or the installation of new equipment is done under the authority of the Town of Barnstable Building Electrical Inspector William Amara. We will copy this inspection to him and review conditions with him. You should plan on communicating with him for approval before beginning any corrective actions. 1. ' Remove and properly correct the wiring for the lights in the elevator equipment room. This lighting is powered from an extension cord that is plugged into a wall outlet in the climate controlled storage area. It then penetrates * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 5 } Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page the wall into the elevator control room where it is hardwired into an electrical box. .(1st cited 29-MAR-12) '[CORRECTED 4/13/131 2. The wiring in the elevator control room is surface mounted. Surface mounted wiring must be run in conduit or otherwise properly protected from damage. (1st cited 29-MAR-12) [CORRECTED 4/13/13] 3. Remove the extension cord that runs from the sprinkler control room, through a sprinkler piping opening in the exterior wall and out to the parking lot. Install proper exterior G.F.I. outlets if needed for vehicle charging and/or block warming in this area. 4. In the 1000?s storage area remove the extension cord plugged in near electrical panel D. This cord runs out through and overhead door to the exterior. Install proper exterior G.F.I. outlets if needed for vehicle charging and/or block warming in this area. 5. Properly remove abandoned electrical wiring and conduit from numerous areas. 6. Repair the broken electrical equipment in the electrical room off of the main showroom. 7. Properly repair and enclosed exposed electrical connections in numerous areas. One example is the ceiling of the main showroom near the main entrance. WALL HYDRANT 'l. The water supply was found shut-off to this device. Discussions with the sprinkler company indicate there may be leaks in the system. It shall be repaired and' returned to service. The system shall be protected against freezing (in a code compliant manner) and shall remain on year round. (1st cited 29-MAR-12) 2. Properly secure and/or properly supervise with the fire alarm system the control valve in the sprinkler room. 3. Install bollards in front of the wall hydrant connection to prevent vehicles from being parked so as to obstruct fire department access to this equipment. 4. Install reflective a. sign ?fire dept. wall hydrant? at least 6 ft. over the connection on the building. The sign shall be a minimum of 18? long by 6? tall. with a white background and red letters. BUILDING CONSTRUCTION ISSUES The comments below are based upon existing conditions, approval of repairs and/or renovations are the authority of the Town of Barnstable Building Commissioner Thomas Perry. We will copy this inspection to him and review conditions with him. You should plan on providing his office with plans for approval before beginning any corrective actions. 1. The storage area located under the stairs leading to the apartment has an * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 6 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "171011 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division -Page open ceiling area exposing the non-sprinkler protected void space above the ceiling in the climate control storage area. There is also exposed wood frame construction in the area. This must be properly enclosed with sheetrock or other approved materials. (1st cited 29-MAR-12) . 2. Repair holes in the ceiling above the electrical panel in the 4000?s adjacent to the elevator lift. 3. Sheetrock all exposed wood frame construction in the elevator equipment room. 4 . Hitch Bay area, properly seal up the numerous holes' in the walls separating this area from the main show room. 5. In the break room sheetrock or otherwise properly cover the exposed rigid foam insulation on the wall in this room. 6. The apartment- (discussion indicated the desire for the apartment to remain and be rehabilitated. As such the follow is required; a. Repair/replace the missing and collapsed ceiling tiles. b. The bedroom windows do not appear to be code complaint as emergency egress windows. They must comply with the maximum allowable sill height from the apartment floor and provide the minimum amount clear opened square inches required. C. The apartment and its interior staircase are not separated from the storage areas by proper construction. d. The apartment has a glass slider that allows access directly to the 2nd floor storage area. In addition to providing no rated separation between the occupancies the floors of the apartment and the storage area are at different heights. The apparent combustible void space below the storage area is exposed when the slider is opened as the storage floor is approx. 6 inches higher that the apartment floor. This must be properly corrected. 04/24/2014 1.06(2) Failure to maintain a fire protection. 1 0 Notes:Violation carried over from inspection on 12/05/2014 Violation carried over from inspection on 04/24/2014 Failure to maintain a fire protection system DEVICES ARE TO ANNUNCIATE DEVICE BY DEVICE TO THE ALARM CO. (NEW ENGLEAND SAFETY SYSTEMS) 04/24/2014 1. 06(2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on .12/05/2014 Violation carried over from inspection on 04/24/2014 Failure to maintain a fire protection system NO CERTIFICATION PAPERWORK ISSUED. I * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 7 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page 04/24/2014 * 1.06 (2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 12/05/-201-4 Failure to maintain a fire protection system The sprinklerisystem found shut-off compressor found mechanically disconnected control valves are not secured or monitored WPIV not-indicating a position 04/24/2014 * 1.06 (2) Failure to maintain a fire protection 1 0 Notes: Failure to maintain a fire protection system The sprinkler system found shut-off compressor found mechanically disconnected control valves are not secured or monitored WPIV not indicating a position 04/24/2014 1.06 (2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 04/24/2014 Failure to maintain a fire protection system DEVICES ARE TO ANNUNCIATE DEVICE BY DEVICE TO THE ALARM CO. (NEW ENGLEAND SAFETY SYSTEMS) 04/24/2014 1.06 (2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 04/24/2014 Failure to maintain a fire protection system NO CERTIFICATION PAPERWORK ISSUED. 04/24/2014 1.06 (2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 12/05/2014 Violation carried over from inspection on 04/24/2014 Failure to maintain a fire protection system NO HORN STROBES HAVE BEEN INSTALLED IN THE APARTMENT AREAS. 04/24/2014 * 1.06 (.2),. Failure to maintain a fire protection 1 0 Notes: Failure to maintain a fire protection system 1. The water motor gong has been disconnected from the system, it must be removed. 2. Properly chain .and lock the exterior WPIV valve and/or properly supervise with the fire alarm system. 3. Properly secure and/or properly supervise with the fire alarm system the * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 8 Hyannis Fire Department Inspection Violations by Occupancy . Occupancy ID = "171011 1710 U-HAUL 594 BEARSES Wy Hyannis, MA 02601 Reported Code/Description Count Article Division Page system control valves in the sprinkler room. 4. There is an abandoned 2nd floor office area located above the rear loading dock area. The ceiling shall be removed from this area to allow proper sprinkler protection. 5. Install bollards in front of the fire department connection to prevent vehicles from. being parked so as to obstruct fire department access to this equipment. (24-APR-14) jersey barriers have been installed in front of the FDC; U-Haul still parks vehicles in front of the FDC. 6. Install reflective a sign ?fire dept. connection? at least 6 ft. over the FDC on the building. The sign shall be a minimum of 18? long by 6? tall with a white background and red letters. 7. NEW: (24-APR-14) the ceiling in the apartment has been removed, exposing (11) non-compliant wet pendant sprinkler heads. These heads and associated piping hold water and present. a freeze hazard. They shall be removed and proper sprinkler protection (upright heads or dry pendant assemblies) installed. ' 8 . NEW: (24-APR-14) The former ?wash bay? is now in use storing u-box containers and new overhead doors have been installed. Provide proper sprinkler protection under the overhead doors. 9. NEW: (24-APR-14) The condensate drains- along the whole back row of storage lockers (example near locker 1056) still have the valve handles in,place and are not secured, allowing for accidental/intentional operation. These are to be removed or secured. 04/24/2014 1.06(2) Failure to maintain a fire protection 1 0 Notes: Failure to maintain a fire protection system DEVICES ARE TO ANNUNCIATE DEVICE BY DEVICE TO THE ALARM CO. (NEW ENGLEAND SAFETY . SYSTEMS) 04/24/2014 1.06(2) Failure to maintain afire protection 1 0 Notes: Failure to maintain a fire protection system. r NO CERTIFICATION PAPERWORK ISSUED. 04/24/2014 1.06(2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 04/24/2014 Failure to maintain a fire protection system NO HORN STROBES HAVE BEEN INSTALLED IN THE APARTMENT AREAS. 04/24/2014 1.06 (2) Failure to maintain a fire protection 1 0 Notes: Failure to maintain a fire protection system * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 9 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = 111710" 1710 U-HAUL 594 BEARSES Wy Hyannis, MA 02601 Reported Code/Description Count Article Division Page NO HORN STROBES HAVE BEEN INSTALLED IN THE APARTMENT AREAS. 04/24/2014 10.03 (2) Failure. to maintain emergency/exit 1 527 CMR 10 0 Notes: Failure to maintain emergency/exit lighting. EXIT SIGNAGE EMERGENCY LIGHTS & EXITS 1. A new exit door and exterior stairs have been installed in the 3000?s. The exit signage shall be adjusted to direct occupants to this door, not to the dead-end loading dock area. Mark this new door as _the exit door. 2. Exit doorway leading out onto the covered loading dock (near storage locker 1011) . For this to be code complaint the following must be done; 2a. Install door hardware allowing customers to open the door without any special equipment or knowledge (the door presently has a keyed lock on the inside) 2b. Exit sign installed, Cover this exit sign, as there is no code compliant way off of the exterior dock. 2c. Install a set of code complaint stairs with railings, or a ramp, leading off of the loading dock platform to grade. 2d. Install emergency lighting on the exterior platform to direct customers to the stairs as' well as allowing them to see them. 3. Install regular lighting to illuminate the loading dock and stairs. 4. The second floor storage area is served by one open exit staircase and an open lift elevator. The area is also open .to the lower 1000?s storage area. The Building Department may require a second means of egress from this area. (24-APR-14) discussion occurred again regarding providing a 2nd means of egress from this area utilizing the existing interior stairs serving the apartment, that lead to the heated storage area. Hyannis Fire recommends this be accomplished. 5. (4/13/13) Exit signage in the heated storage area directs people to the marked exit door into the main store display area. This door has a locking keypad and key lock on it. To provide emergency exit until this can be corrected Mr. Olio has agreed to leave this door unlocked 6. A new front main entrance/exit door has been installed. The exit sign is located over the old exit door and this door is blocked by displays and storage. Keep this exit door clear and accessible,until such time as the exit sign is moved over the new main entrance. Corrected during the inspection. 04/24/2014 10.03 (2) Failure to maintain emergency/exit 1 527 CMR 10 0 Notes:Violation carried over from inspection on 04/24/2014 Failure to maintain emergency/exit lighting. * Denotes Violations Corrected or Variance Issued Page 10 1"_/16/2015 16:04 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page EXIT SIGNAGE EMERGENCY LIGHTS & EXITS 1. A new exit door and exterior stairs have been installed in the 3000?s. The exit signage shall be adjusted to direct occupants to this door, not to- the dead-end loading dock area: Mark this new door as. the exit door. 2. Exit doorway leading out onto the covered loading dock (near storage locker 1011) . For this to be code complaint the following must be done; 2a. Install door hardware allowing customers to open the door without any special equipment or knowledge (the door presently has a keyed lock on the inside) 2b. Exit sign installed, Cover this exit sign, as there is no code compliant way off of the exterior dock. 2c. Install a set of code complaint stairs with railings, or a ramp, leading off of the loading dock platform to grade. 2d. Install emergency lighting on the exterior platform to direct customers to the stairs as well as allowing them to see them. 3. Install regular lighting to illuminate the loading dock and stairs. 4. The second floor storage area is served by one open exit staircase and an open lift elevator. The area is also open to the lower 1000?s storage area. The Building Department may require a second means, of egress from this area.. (24-APR-14) discussion occurred again regarding providing a 2nd means of egress from this area utilizing the existing interior stairs serving the apartment, that lead to the heated storage area. Hyannis Fire recommends this be accomplished. S. (4/13/13) Exit signage in the heated storage area directs people to the marked exit door into the main store display area. This door has a locking keypad and key lock on it. To provide emergency exit until this can be corrected Mr. Olio has agreed to leave this door unlocked 6. A new front main entrance/exit door has been installed. The exit sign is located over the old exit door and.this door is blocked by displays and storage. Keep this exit door clear and accessible until such time as the exit sign is moved over the new main entrance. Corrected during the inspection. t. 04/24/2014 10.03 (2) Failure to maintain emergency/exit 1 527 CMR 10 0 Notes: Failure to maintain emergency/exit lighting. NEW: (24-APR-14) the emergency light located near locker 1001 was found to be out of service. _ * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 11 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "171011 1710 U-HAUL 5974 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page 04/24/2014 10.03 (2) Failure to maintain emergency/exit 1 527 CMR 10 0 Notes:Violation carried over from inspection on 12/05/2014 Violation carried over from inspection on 04/24/2014 1 -Failure to maintain emergency/exit lighting. EXIT SIGNAGE EMERGENCY LIGHTS & EXITS 1. A new exit door and exterior stairs have been installed in the 3000?s. The exit signage shall be adjusted to direct occupants to this door, not to the dead-end loading dock area. Mark this new door as the exit door. 2. Exit doorway leading out onto the covered loading dock (near storage locker 1011) . For this to be code complaint the following must be done; 2a. Install door hardware allowing customers to open the door without any special equipment or knowledge (the door presently has a keyed lock on the inside.) 2b. Exit sign installed,- Cover this exit sign, as there is no code compliant way. off of the exterior dock. 2c. Install a set of code complaint stairs with railings, or a ramp, leading .off of the loading dock platform to grade. 2d. Install emergency lighting on the exterior platform to direct customers to the stairs as well as allowing them to see them. 3. Install regular lighting to illuminate the loading dock and stairs. 4. The second floor storage area is served by one open exit staircase and an open lift elevator. The area is also open to the lower 1000?s storage area. The Building Department may require a second means of egress from this area. (24-APR-14) discussion occurred again regarding providing a 2nd means of egress from this area utilizing the existing interior stairs serving the apartment, that lead to the heated storage area. Hyannis Fire recommends this be accomplished. 5. (4/13/13) Exit signage in the heated storage area directs people to the marked exit door into the main store display area. This door has a locking keypad and key lock on it. To provide emergency exit until this can be corrected Mr. Olio has agreed to leave this door unlocked i 6. A new front main entrance/exit door has been installed. The exit sign is located over the old exit door and this door is blocked by displays and storage. Keep this exit door clear and accessible until such time as the exit sign is moved over the new main entrance. Corrected during the inspection. 04/24/2014 10.03 (2) Failure to maintain emergency/exit 1 527 CMR 10 0 Notes:Violation carried over from inspection on 04/24/2014 * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 12 Hyannis Fire Department Inspection Violations' by Occupancy Occupancy ID = "171011 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page Failure to maintain emergency/exit lighting. NEW: (24-APR-14) the emergency light located near locker 1001 was found to be out of service. 04/24/2014 10.03 (2) Failure to maintain emergency/exit 1 527 CMR 10 0 Notes:Violation carried over from inspection on 12/05/2014 Violation carried over from inspection on 04/24/20-14 Failure to maintain emergency/exit lighting. NEW: (24-APR-14) the emergency light located near locker 1001 was found to be out of service. 04/24/2014 10.03 (5) (A) Improper storage of 1 0 Notes:Violation carried over from inspection on 12/05/2014 Violation carried over from inspection on 04/24/2014 Improper storage of combustible or flammable material. 1. In the blanket storage area remove all of the storage in the ceiling on the bottom chord of the steel truss assembly. This storage obstructs the sprinkler heads for this area. 2. NEW: (24-APR-14) Remove the U-box storage from the hitch bay area. The garage area is not appropriate for bulk storage, the sprinkler system may not have the hazard rating to handle this two box high storage, and sufficient access aisles around the storage cannot be provided. 04/24/2014 10.03 (5) (A) Improper storage of 1 0 Notes:Violation carried over from inspection on 04/24/2014 Improper storage of combustible or flammable material. 1. In the blanket storage area remove all of the storage in the ceiling on the bottom chord of the steel truss assembly. This storage obstructs the sprinkler heads for this area. 2. NEW: (24-APR-14) Remove the U-box storage from the hitch bay area. The garage area is not appropriate for bulk storage, the sprinkler system may not have the hazard rating to handle this .two box high storage, and sufficient access aisles around the storage cannot be provided. 04/24/2014 10.03(5) (A) Improper storage of 1 0 Notes: Improper storage of combustible or flammable material. * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 13 Hyannis Fire Department Inspection Violations 'by Occupancy Occupancy ID = "171011 L710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Count Article Division Page Reported Code/Description 1. In the blanket storage area remove all of the storage in the ceiling on the bottom chord of the steel truss assembly. This storage obstructs the sprinkler heads for this area. 2. NEW: (24-APR-14) Remove the U-box storage from the hitch bay area. The garage m may not have the area is not appropriate for bulk storage, the sprinkler syste y hazard rating to handle this two box high storage, and sufficient access aisles around the storage cannot be provided. 04/24/2014 25.03 Retail Occ. exterior access 1 25.03 0 Notes:EXITS DO NOT LEAD TO A PUBLIC WAY AS THE REAR PROTION OF THE YARD IS NOW FENCED IN AND GATED FOR VEHICLES ONLY, NO EGRESS TO THE STREET OF PEOPLE FROM THIS AREA. 04/24/2014 25.03 Retail Occ. exterior access 1 25.03 0 Notes:Violation carried over from inspection on 12/05/2014 Exterior access to two side of a retail occupancy. 1. Gates still closed to pedestrian exit path, 2. Gates have no safety devices to prevent people or vehicles from being pinned by the gate ( safeties that were installed were found to have been damaged by vehicle traffic) position u nitl issued resolved. gates to be left in the open 04/24/2014 25.03 Retail Occ. exterior access 1 25.03 0 Notes:Exterior access to two side of a retail occupancy. 1'. Gates still closed to pedestrian exit path, 2. Gates have no safety devices to prevent people or vehicles from being pinned by the gate ( safeties that were installed were found to have been damaged by vehicle traffic) gates to be left in the open position unitl issued resolved. 09/02/2014 * 1.03 (2) Report of violations to other code 1 0 Notes- Working on punch list with Deputy and uhaul staff 09/02/2014 * 1.03 (2) Report of violations to other code 1 0 Notes:Recheck violation record auto-generated from ManageMyInspections.com recheck request. * Denotes Violations Corrected or Variance Issued Page 14 11/16/2015 16:04 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page Original Violation Remarks: Working on punch list with Deputy and uhaul staff 09/02/2014 * 25.03 Retail Occ. exterior access 1 25.03 0 Notes:Recheck violation record auto-generated from ManageMyInspections.com recheck request. Original Violation Remarks: Exterior access to two side of a retail occupancy. Keeping gates open during normal business operations 09/02/2014 * 25.03 Retail Occ. exterior access 1 25.03 0 Notes: Exterior access to two side of a retail occupancy. Keeping gates open during normal business operations 12/05/2014 1.06(2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 04/13/2013 Violation carried over. from inspection on 04/16/2012 Failure to maintain a fire protection system SYSTEM TESTING INDICATES MANY CITED PROBLEMS WHICH HAVE NOT BEEN ADDRESSED. 12/05/2014 1.06(2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 12/05/2014 Violation carried over from inspection on 04/13/2013 Violation carried over from inspection on 04/16/2012 Failure to maintain a fire protection system SYSTEM TESTING INDICATES MANY CITED PROBLEMS WHICH HAVE NOT BEEN ADDRESSED. 11/16/2015 1.03 (2) Report of violations to other code 1 0 Notes:ELECTRICAL ISSUES General Observations. There were numerous problems noted. Mr Souza from F & S Electric was in attendance during the inspection and made his own detailed list of issues. The comments below are based upon existing conditions, approval of repairs and/or the installation of new equipment is done under the authority of the Town of Barnstable Building Electrical Inspector William Amara. We will copy this inspection to him and review conditions with him. You should plan on communicating with him for approval before beginning any corrective actions. 1. Remove and properly correct the wiring for the lights in the elevator equipment room.. This lighting is powered from an extension cord that is plugged * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 15 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710"_ 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page into a wall outlet in the climate controlled storage area. It then penetrates the wall into the elevator control room where it is hardw-ired into an electrical box. (1st cited 29-MAR-12) 2. The wiring in the elevator control room is surface mounted. Surface- mounted wiring must be run in conduit or otherwise properly protected from damage. (1st cited 29-MAR-12) 3. Remove the extension cord that runs from the sprinkler control room, through a sprinkler piping opening in the exterior wall and out to the. parking lot. Install proper exterior G.F.I. outlets if needed for vehicle charging and/or block warming in this area. 4. In the 1000?s storage area remove the extension cord plugged in near electrical panel D. This cord runs out through and overhead door to the exterior. Install proper. exterior G.F.I. outlets if needed for vehicle charging and/or block warming in this area. 5. Properly remove abandoned electrical wiring and conduit from numerous areas. 6. Repair the broken- electrical equipment in the electrical room off of the main showroom. 7. " Properly repair and enclosed exposed electrical connections in numerous areas. One example is the ceiling of the main showroom near the main entrance. WALL HYDRANT 1. The water supply was found shut-off to this device. Discussions with the sprinkler company indicate there may be leaks in the system. It shall be repaired and returned to service. The system shall be protected against freezing (in a code compliant manner) and shall remain on year round. (1st cited 29-MAR-12) 2. Properly secure and/or properly supervise with the fire alarm system the control valve in the sprinkler room. 3. Install bollards in front of the wall hydrant connection to prevent vehicles from being parked so as to obstruct fire department access to this equipment. 4. Install reflective a sign ?fire dept. wall hydrant? at least 6 ft. over the connection on the building. The ,sign shall be a minimum of 18? long by 6? tall with a white background and red letters. BUILDING CONSTRUCTION ISSUES The comments below are based upon existing conditions, approval of repairs and/or renovations are the authority of the Town of Barnstable Building Commissioner ThomasrPerry. We will copy this inspection to him and review conditions with him. You should plan on providing his office with plans for approval before beginning any corrective actions. . Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 16 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 13EARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page 1. The storage area located under the _stairs leading to the apartment has an open ceiling area exposing the non-sprinkler protected void space above the ceiling in the climate control storage area. There is also exposed- wood frame construction in the area. This must be properly enclosed with sheetrock or other approved materials. (1st cited 29-MAR-12) . 2. Repair holes in the ceiling above the electrical panel in the 4000?s adjacent to the elevator lift. 3. Sheetrock all exposed wood frame construction in the elevator equipment room. 4 . Hitch Bay area, properly seal up the numerous holes in the walls separating this area from the main show room. S. In the break room sheetrock or otherwise properly cover the exposed rigid foam insulation on the wall in this room. 6. The apartment (discussion indicated the desire for the apartment to remain and be rehabilitated. As such the follow is required; a. Repair/replace the missing and collapsed ceiling tiles. b. The bedroom windows do not appear to be code complaint as emergency egress windows. They must comply with the maximum allowable sill height from the apartment floor and provide the minimum amount clear opened square inches required. C. The apartment and its interior staircase are not separated from the storage areas by proper construction. d. The apartment has a glass slider that allows access directly to the 2nd floor storage area. In addition to providing no rated separation between the the floors of the apartment and the storage area are at different occupanciesP heights below the storage area is exposed The apparent combustible void space g P when the slider is opened as,the storage floor is approx. 6 inches higher that the apartment floor. This must be properly corrected. 11/16/2015 1.03(2) Report of violations to other code 1 0 Notes:Violation carried over from inspection on 04/16/2012 ELECTRICAL ISSUES General Observations. There were numerous problems noted. Mr Souza .from F & S Electric was in attendance during the inspection and made his own detailed list of issues. The comments below are based upon existing conditions, approval;of repairs and/or the installation of new equipment is done under the authority of the Town of Barnstable Building Electrical Inspector William Amara. We will copy this inspection to him and review conditions with him. You should plan on r communicating with him for approval before beginning any corrective actions. 1. Remove and properly correct the wiring for the lights in the elevator * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 17 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" t 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 .Reported -Code/Description Count Article Division Page equipment room. This lighting is powered from an extension cord that is plugged into a wall outlet in the c-limate controlled storage area. It then penetrates the wall into the elevator control room where it is hardwired into an electrical box. •(lst cited 29-MAR-12) [CORRECTED 4/13/13] 2. The wiring in the elevator control room is surface mounted. Surface mounted wiring must be run in conduit or otherwise properly protected from damage. (1st cited 29-MAR-12) [CORRECTED 4/13/13] 3. Remove the extension cord that runs from the sprinkler control room, through a sprinkler piping opening in the exterior wail and out to the parking lot. Install proper exterior G.F.I. outlets if needed for vehicle charging and/or block warming in this area. 4. In the 1000?s storage area remove the extension cord plugged in near electrical panel D. This cord runs out through and overhead door to the exterior. Install proper exterior G.F.I. outlets if needed for vehicle charging and/or block warming in this area. 5. Properly remove abandoned electrical wiring and conduit from numerous areas. 6. Repair the broken electrical equipment in the electrical room off of the main showroom. 7. Properly repair and enclosed exposed electrical connections in numerous areas. One example is the ceiling of the main showroom near the main entrance. WALL HYDRANT 1. The water supply was found shut-off to this device. Discussions with the sprinkler company indicate there may be leaks in the system. It shall be repaired and returned to service. The system shall be protected against freezing (in a code compliant manner) and shall remain on year round. (1st cited 29-MAR-12) 2. Properly secure and/or properly supervise with the fire alarm system the control valve in- the sprinkler room. 3. Install bollards in front of the wall hydrant connection to prevent vehicles from being parked so as. to obstruct fire department access to this equipment. 4. Install reflective a sign ?fire dept. wall hydrant? at least 6 ft. over the connection on the building. The sign shall be a minimum of 18? long by 6? tall with a white background and red letters. BUILDING CONSTRUCTION ISSUES The comments below are based upon existing conditions, approval of repairs and/or renovations are the authority of the Town of Barnstable Building Commissioner Thomas Perry. We will copy this inspection to him and review conditions with him. You should plan on providing his office with plans for * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 18 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "171011 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page approval before beginning any corrective actions. 1. The storage area located under the stairs leading- to. the apartment has an open ceiling area exposing the non-sprinkler protected void space above the ceiling in the climate control storage area. There is also exposed wood frame construction in the area. This must be properly enclosed with s-heetr'ock or other approved materials. (1st cited 29-MAR-12) . 2. Repair holes in the ceiling above the electrical panel in the 4000?s adjacent to the elevator lift. 3. Sheetrock all exposed wood frame construction in the elevator equipment room. 4. Hitch Bay area, properly seal up the numerous holes in the walls separating this area from the main show room. 5. In the break room Sheetrock or otherwise properly cover the exposed rigid foam insulation on the wall in this room. 6. The apartment (discussion indicated the desire for the apartment to- remain and be rehabilitated. As such the follow is required; a. Repair/replace the missing and collapsed ceiling tiles. b. The bedroom windows do not appear to be code complaint as emergency egress windows. They must comply with the maximum allowable sill height from the apartment floor and provide the minimum amount clear opened square inches required. C. The apartment and its interior staircase are not separated from the storage areas by proper construction. d. The apartment has a glass slider that allows access directly to the 2nd floor storage area. In addition to providing no rated separation between the occupancies the floors of the apartment and the storage area are at different heights. The apparent combustible void space below the storage area is exposed when the slider is opened as the storage floor is approx. 6 inches higher that the apartment floor. This must be properly corrected. 11/16/2015 * 1.06(2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 04/16/2012 Failure to maintain a fire protection system SPRINKLER SYSTEM 1. Properly monitor the fire sprinkler system. A trip test of the sprinkler system revealed the system is .not monitored. 2. The water line to the motor gong was found off, Turned on during inspection. Test and verify this equipment is operational. 3. Properly chain and lock the exterior WPIV valve and/or properly supervise with the fire alarm system. I * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 19 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page 4 . Properly secure and/or properly supervise with the fire alarm system the system control valves in the sprinkler room. 5. Interior heated storage area. Provide proper sprinkler head coverage for the hallways and the storage lockers. Presently the storage locker height is closer than 18? to the sprinkler heads limiting their area of coverage leaving hallways unprotected. CORRECTED 4/13/13 6. In the 1000?s interior storage area (lower lockers) all lockers were found be unprotected. All of these lockers shall have sprinkler protection provided. 7. In the 2000?s interior storage area plastic covering has been installed over the lockers obstructing the sprinkler protection. The plastic shall be removed. 8 . The rear covered loading dock area does not have sprinkler protection. Sprinklers shall be installed in this area. 9. There is an abandoned 2nd floor office area located above the rear loading dock area. This area was not accessible during the inspection. Visually we could see that there was a partial collapse/removal of the ceiling in this area. This area shall be inspected to ensure proper sprinkler protection. 10. The stairwell leading from the interior heated storage area to the apartment shall have sprinkler protection installed. (1st cited 29-MAR-12) 11. The 2nd floor apartment shall have sprinkler protection installed throughout. (1st cited 29-MAR-12) 12. The storage/electrical room located below the stairwell to the 2nd floor apartment shall have sprinkler protection installed. (lst cited 29-MAR-12) CORRECTED 4/13/13 13. Storage lockers 3001 and 3002 shall have sprinkler protection installed. 14a. The bathroom corridor located off of the main show room shall have sprinkler protection installed. 14b, The public bathrooms off of the showroom shall be sprinkler protected CORRECTED 4/13/13 15. The electrical closet located off of the bathroom corridor shall have sprinkler protection installed. 16. Provide sprinkler protection under the three overhead garage doors in the hitch bay. CORRECTED 4/13/13 17. There are low point condensation drains located throughout the property. Remove or secure the control valve operating handles to prevent accidental opening and/or tampering with the system. 4/13/13 SOME CORRECTED, MOST STILL NOT. 18. Convert the FDC connection on the front of the building to a 4? storz connection equipped with a 30' down angle fitting. 19. Install bollards in front of the fire department connection to prevent vehicles from being parked so as to obstruct fire department access to this * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 20 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page equipment. 20. Install reflective a sign ?fire dept. connection? at least 6 ft. over the FDC on the building. The sign shall be a minimum of 18? long by 6? tall with a white background and red letters. 11/16/2015 1.06(2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 04/16/2012 Failure to maintain a fire protection system SYSTEM TESTING INDICATES MANY CITED PROBLEMS WHICH HAVE NOT BEEN ADDRESSED. 11/16/2015 1.06 (2) Failure to maintain a fire protection 1 0 Notes: Failure to maintain a fire protection system, FIRE ALARM SYSTEM The property requires smoke detection, sprinkler monitoring and carbon monoxide protection. The alarm system shall be monitored by an approved alarm company. A set of detailed plans shall be submitted to the Hyannis Fire Department by a licensed alarm company as part of the permit process for approval of these systems. 1. There is no working fire alarm system in the building. This inspection found electrically powered residential style smoke detectors installed throughout the showroom and storage areas. Many of these devices were found to be damaged and we were unable to find any working units. 2. A trip test of the sprinkler system sounded no alarms at the property. No monitoring company detected an alarm activation. 3. Battery operated detectors were found in the apartment. Some units were found disassembled and others had low battery alarms sounding.. 4 . A fire alarm system in this mixed use occupancy is required. It shall comprise, a. Smoke detection in _the common areas and egress pathway of the apartment. The activation of any one device shall sound a property wide alarm. b. Local smoke detection within the apartment is acceptable. The units shall be interconnected and battery backed up. C. The required sprinkler protection shall negate the need for heat detection in the apartment. d. Horn/strobe assemblies shall be appropriately provided throughout the building, including the apartment, to provide appropriate notification of an alarm activation. e. As noted in the sprinkler section, the sprinkler system shall be properly monitored and a water flow shall sound an alarm throughout the building. f. Carbon monoxide detection is required as the building utilizes gas heat and has a vehicle garage. This detection shall encompass the main showroom, the Denotes Violations Corrected or Variance Issued _ 11/16/2015 16:04 Page 21 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" P Y 1710 U-RAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page climate controlled storage area, the` 2nd floor storage area, and the apartment as a minimum. 11/16/2015 1.06(2) Failure to maintain a fire protection 1 0 Notes:Violation carried over from inspection on 04'/16/2012 Failure to maintain a fire protection system, ' FIRE ALARM SYSTEM The property requires- smoke detection, sprinkler monitoring and carbon monoxide \ protection. The alarm system shall-be monitored by an approved alarm company. A set of detailed plans shall be submitted to the Hyannis Fire Department by a licensed alarm company as part of the permit process for approval of these systems. 1. There is no working fire alarm system in the building. This inspection found electrically powered residential style smoke detectors installed throughout the showroom and storage areas. Many of these devices were found to be damaged and we were unable to find any working units. [4/13/13 the fire alarm system work has not been fully completed, it has been installed and; la. the non-working pull stations are not covered or labeled out of service. lb. The system that does work is sounds limited alarms locally. lc. The fire alarm monitoring company (U-Haul Phoenix Office) called the property upon receipt of the fire alarm. The fire alarm system shall be monitored by a code compliant Central Alarm Station. 2. A trip test of the sprinkler system sounded no alarms at the property. No monitoring company detected an alarm activation. 3. Battery operated detectors were found in the apartment. Some units were found disassembled and others had low battery alarms sounding. (REMOVED 4/13/13) 4 . A fire alarm system in this mixed use occupancy is required. It shall comprise, a. Smoke detection in the common areas and egress pathway of the apartment. The activation of any one device shall sound a property wide alarm. b. Local smoke detection within the apartment is acceptable. The units shall be interconnected and battery backed up. [4/13/13 APT. TO REMAIN VACANT. REQUIREMENTS LEFT ON REPORT AS A GUIDE FOR MINIMUMS TO OCCUPY. ] C. The required sprinkler protection shall negate the need for heat detection in the apartment. d. Horn/strobe assemblies shall be appropriately provided throughout the building, including the apartment, to provide appropriate notification of an alarm activation. e. As noted in the sprinkler section, the sprinkler system shall be properly monitored and a water flow shall sound an alarm throughout the building. * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 22 Hyannis- Fire Department Inspection ,Violations by Occupancy Occupancy ID = "1710" A 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page f. Carbon monoxide detection is required as the building utilizes gas heat and has a vehicle garage. This detection -shall encompass the main showroom, the climate controlled storage area, the 2nd floor storage area, and the apartment as a minimum. [4/13/13 APT. TO REMAIN VACANT. REQUIREMENTS LEFT ON REPORT AS A GUIDE FOR MINIMUMS TO OCCUPY. ] 11/16/2015 * 1.06(2) Failure tomaintain a fire protection 1 0 Notes: Failure to maintain a fire protection system SPRINKLER SYSTEM 1. Properly monitor the fire sprinkler system. A trip test of the sprinkler system revealed the system is not monitored. 2. The water line to the motor gong was found off, Turned on during inspection. Test and verify this equipment is operational. 3. Properly chain and lock the exterior WPIV valve and/or properly supervise with the fire alarm system. 4. Properly secure and/or properly supervise with the fire alarm system the system control valves in the sprinkler room. 5. Inter.ior heated storage area. Provide proper sprinkler head coverage for the hallways and the storage lockers. Presently the storage locker height is closer than 18? to the sprinkler heads limiting their area of coverage leaving hallways unprotected. 6. In the 1000?s interior storage area (lower lockers) all -lockers were found be unprotected. All of these lockers shall have sprinkler protection provided. 7. In the 2000?s interior storage area plastic covering has been installed over the lockers obstructing the sprinkler protection. The plastic shall be removed. 8. The rear covered loading dock area does not have sprinkler protection. Sprinklers shall be installed in this area. 9. There is an abandoned 2nd floor office area located above the rear loading dock area. This area was not accessible during the inspection. Visually we could see that there was a partial collapse/removal of the ceiling in this area. This area shall be inspected to ensure proper sprinkler protection. 10. The stairwell leading from the interior heated storage area to the apartment shall have sprinkler protection installed. (1st cited 29-MAR-12) 11. The 2nd floor apartment shall have 'sprinkler protection installed throughout. (1st cited 29-MAR-12) 12. The storage/electrical room located below the stairwell to the 2nd floor apartment shall have sprinkler protection installed. (1st cited 29-MAR-12) 13. Storage lockers 3001 and 3002 shall have sprinkler protection installed. 14. .The bathroom corridor located off of the main show room shall have sprinkler protection installed. * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 23 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710` U-HAUL 594 BEARSES Wy Hyannis, MA 02601 Reported Code/Description Count Article Division Page 15. The electrical closet located off of the bathroom corridor shall have sprinkler protection installed. 16. Provide sprinkler protection under the three overhead garage doors in the hitch bay. 17. There are low point condensation drains located throughout the property. Remove or secure the control valve operating handles to prevent accidental opening and/or tampering with the system. 18. Convert the FDC connection on the front of the building to a 4? storz connection equipped with a 30' down angle fitting. 19. Install bollards in front of the fire department connection to prevent vehicles from being parked so -as to obstruct fire department access to this equipment. 20. Install reflective a sign ?fire dept. connection? at least 6 ft. over the FDC on the building. The sign shall be a minimum of 18? long by 6? tall with a white background and red letters. 11/16/2015 1. 06(2) Failure to maintain a fire protection 1 0 Notes: Failure to maintain a fire protection system SYSTEM TESTING INDICATES MANY CITED PROBLEMS WHICH HAVE NOT BEEN ADDRESSED. 11/16/2015 10.03 (2) Failure to maintain emergency/exit 1 527 CMR 10 0 Notes:Violation carried over from inspection on 04/16/2012 Failure to maintain emergency/exit lighting. EXIT LIGHTS 1. In the 3000?s there are exit signs. Install signage to lead customers through this area and into the 4000?s. [4/13/13 Exit signage in this area has been installed directing people to the end of the 3000?s which is a dead-end. There had been discussions regarding installing an exit in this area. Nothing has been approved by the Building Dept. and/or the Hyannis Fire Dept. additional the owner had no knowledge of nor had he approved this work. The offending exit signage has been ordered to be covered until this can be worked out. ] 2. In the 4000?s area improve the exit signage so that both exit paths leading into this area (from the 3000?s and the 1000?s) are properly directed to the climate controlled storage area. CORRECTED 4/13/13 3. The 2000?s are a mezzanine area from which a person can exit in two directions. The shortest exit path id towards the front of the building (Bearse?s Way side) . Install signage that will be visible from the 2000?s and lead customers to. the exit door leading into the 4000?s. CORRECTED 4/13/13 4. The 1000?s receive exiting customers from the 2000?s install exit signage that directs customers in the 1000?s to one of the two available exit door .(into the 4000?s and into the climate controlled storage area) . CORRECTED 4/13/13 * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 24 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "171011 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page 5. There was discussion regarding making a doorway leading out onto the covered loading dock an exit (near storage locker 1011) . For this to be code complaint the following must be done; a. Install door hardware allowing customers to open the door without any special equipment or knowledge (the door presently has a keyed. lock on the inside) b. Install exit signage above the door and proper signage to direct customers here. [4./13/13 EXIT SIGN INSTALLED BUT A KEYLOCK ASSEMBLY SECURES THE DOOR 24/7. COVER THE EXIT SIGN UNTIL THE EXIT IS MADE PROPER. C. Install a set of code complaint stairs with railings leading off of the loading dock platform to grade. d. Install emergency lighting on the exterior platform to direct customers to the stairs as well as allowing them to see them. e. Install regular lighting to illuminate the loading dock and stairs.- 6. The second floor storage area is served by one open exit staircase and an open lift elevator. The area is also open to the lower 1000?s _storage area. The Building Department may require a. second means of egress from this area. 3. 4/13/13 Exit signage in the heated storage area directs people to the marked exit door into the main store display area. This door has a locking keypad and keylock on it. To provide emergency exit until this can be corrected Mr. Olio has agreed to leave this door unlocked. 11/16/2015 * 10.03 (2) Failure to maintain emergency/exit 1 527 CMR 10 0 Notes:Violation carried over from inspection on 04/16/2012 Failure to maintain emergency/exit lighting. EMERGENCY LIGHTS 1. Repair and/or replace. the following broken emergency lights. a. Main Show Room, lights do not work. b. Interior heated storage area, lights do not work. C. Electrical/Storage room off of the heated storage area has an emergency light unit inside that also does not work. d. In the 4000?s storage area both emergency light units do not work and, the one closest to the elevator is physically broken. e. In the 2nd floor storage area, the emergency light in the hall by the apartment slider worked by stayed on after testing. f. In the 2nd floor storage area on the back side the emergency light did not work. g. In the 2nd floor storage area at the top of the access stairs the emergency light did not work. * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 25 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "171011 1710 U-HAUL, 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page 2. Install emergency lighting in the 1000?s storage locker area. 3. Install emergency lighting in the 2.000?s storage locker area. Cover the staircases. 4. Install emergency lighting in the 3000?s storage locker area. 5. Install emergency lighting in the apartment staircase area. 6. Install emergency lighting in the hitch bay area and the storage area at the break room. 11/16/2015 10.03 (2) Failure to maintain emergency/exit 1 527 CMR 10 0 Notes: Failure to maintain emergency/exit lighting. EXIT LIGHTS 1. ` In the 3000?s there .are exit signs. Install signage to lead customers through this area and into the 4000?s. 2. In the 4000?s area improve the exit signage so that both exit paths leading into this area (from the 3000?s and the 1000?s) are properly directed to the climate controlled storage area. 3. The 2000?s are a mezzanine area from which a person can exit in two directions. The shortest exit path id towards the front of the building (Bearse?s Way side) . Install signage that will be visible from the 2000?s and lead customers to the exit door leading into the 4000?s. 4 . The 1000?s receive exiting customers from the 2000?s install exit signage that directs customers in the 1000?s to one of the two available exit door (into the 4000?s and into the climate controlled storage area) . 5. There was discussion regarding making a doorway leading out onto the covered loading dock an exit (near storage locker 1011) . For this to be code complaint the following must be done; a. Install door hardware allowing customers to open the door without any special equipment or knowledge (the door presently has a keyed lock on the inside) b. Install exit signage above the door and proper signage to direct customers here. C. Install a set of code complaint stairs with railings leading off of the loading dock platform to grade. d. Install emergency lighting on the exterior platform to direct customers to the stairs as well as allowing them to see them. e. Install regular lighting to illuminate the loading dock and stairs. 6. The second floor storage area is served by one open exit staircase and an open lift elevator. The .area is also open to the lower 1000?s storage area. The Building Department may require a second means of egress from this are ia. * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 26 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page 11/16/2015 * 10.03 (2) Failure to maintain emergency/exit 1 527 CMR 10 0 Notes: Failure to maintain emergency/exit lighting. EMERGENCY LIGHTS 1. Repair and/or replace the following broken emergency lights. a. Main Show Room, lights do not work.- b. Interior heated storage area, lights do not work. C. Electrical/Storage room off of the heated storage area has an emergency light unit inside that also does not work. d. In the 4000?s storage area both emergency light units do not work and, the one closest to the elevator is physically broken. e. In the 2nd floor storage area, the emergency light in the hall by the apartment slider worked by stayed on after testing. f. In the 2nd floor storage area on the back side the emergency light did not work. g. In the 2nd floor storage area at the top of the access stairs the emergency light did not work. 2. Install emergency lighting in the 1000?s storage locker area. 3. Install emergency lighting in the 2000?s storage locker area. Cover the staircases. 4. Install emergency lighting in the 3000?s storage locker area. 5. Install emergency lighting in the apartment staircase area. 6. Install emergency lighting in the hitch bay area and the storage area at the break room. 11/16/2015 10.03 (5) (A) Improper storage of 1 0 Notes: Improper storage of combustible or flammable material. STORAGE ISSUES 1. Remove storage from with in three feet of the electrical panels in the storage area under the stairs leading to the apartment. 2. Remove all storage from the electrical room located adjacent to the bathrooms off of the main showroom. (lst cited 29-MAR-12) 3. In the blanket storage area remove all of the storage in the ceiling on the bottom chord of the steel truss assembly. This storage obstructs the sprinkler heads for this area. r 4. Remove all storage from the compressor room. 5. Remove and relocate to an outside location the dumpster presently in operation in the former vehicle wash bay area. 6. Remove all of the trash, furniture. and other debris from the former vehicle wash bay area. * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 27 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES WY Hyannis, MA 02601 Reported Code/Description Count Article Division Page 11/16/2015 10.03 (5) (A) Improper storage of 1 0 Notes:Violation carried. over . from inspection on 04/16/2012 Improper storage of combustible or flammable material. STORAGE ISSUES 1. Remove storage from with in three feet of the electrical panels in the storage area under the stairs leading to the apartment. CORRECTED 4/13/13 2. Remove all storage from the electrical room located adjacent to the bathrooms off of the main showroom. (1st cited 29-MAR-12)CORRECTED 4/13/13 3. In the blanket storage area remove all of the storage in the ceiling on the bottom chord of the steel truss assembly. This storage obstructs the sprinkler heads for this area. 4. Remove all storage from the compressor room. 5. Remove and relocate to an outside location the dumpster presently in operation in the former vehicle wash bay area. CORRECTED 4/13/13 6. Remove all of the trash, furniture and other debris from the former vehicle wash bay area. 11/16/2015 * 148-SECT 26F Failure to meet code for smokes and 1 0 Notes:Violation carried over from inspection on 04/16/2012 f. Carbon monoxide detection is required (BUILDING HAS A TWO UNIT APARTMENT) as the building utilizes' gas heat and has a vehicle garage. This detection shall encompass the main showroom, the climate controlled storage area, the 2nd floor storage area, and the apartment as a minimum. (4/13/13 not required as long as the apartment is not used. The apartment, as is, is not code compliant and as such all code issues shall be corrected and appropriate inspection coducted before it is used.] 11/16/2015 * 148-SECT 26F Failure to meet code for smokes and 1 0 Notes: f. Carbon monoxide detection is'required (BUILDING HAS A TWO UNIT APARTMENT) as the building utilizes gas heat and has a vehicle garage. This detection shall encompass the main showroom, the climate controlled storage area, the 2nd floor storage area, and the apartment as a minimum. 11/16/2015 * 148-SECT 26F Failure to meet code for smokes and 1 0 Notes:Violation carried over from inspection on 04/13/2013 , Violation carried over from inspection on 04/16/2012 f. Carbon monoxide detection is required (BUILDING HAS A TWO UNIT APARTMENT) .as the building utilizes gas heat and has a vehicle garage. This detection shall encompass the main showroom, the climate controlled storage area, the 2nd floor storage area, and the apartment as a minimum. (4/13/13 not required as long as the apartment is not used. The apartment, as is, is .not code compliant and as * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 28 Hyannis Fire Department Inspection Violations by Occupancy Occupancy ID = "1710" 1710 U-HAUL 594 BEARSES 'WY Hyannis, MA 02601 Reported Code/Description. ' Count Article Division Page such all code issues shall be corrected and appropriate inspection coducted before it is used. ] --------------------------------------------------------------- ------------------------------------ Total Individual Violation Codes for Occupancy: 54 , Grand Total Violations : 54_ J r ' * Denotes Violations Corrected or Variance Issued 11/16/2015 16:04 Page 29 i OFZHE Tp�� Town of Barnstable C� Regulatory Services • BA"SCABLE. v MASS. Thomas F.Geiler,Director �p .i639 ♦0 1e1639 a Building Division Thomas Perry,Building Commissioner 200 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 April 23, 2007 Brandy McGraw, Information Specialist Zoning Analysis Group, Ltd 1012 NW 8 1"Street Oklahoma City, OK 73114 RE: Your request for information regarding 594 Bearses Way, Hyannis/U-Haul Dear Ms. McGraw, In response to your request concerning the above mentioned property's compliance with applicable codes, regulations and ordinances pleased be advised as follows: (I) The Building Commissioner is responsible for enforcement of building codes and zoning ordinances related to development within the Town of Barnstable, Barnstable County, MA. (ii) The property is located in a B zone as indicated in attached documents which provide for the existing uses as indicated on the attached building permit and Certificate of Occupancy. (iii) To the best of my knowledge and within my authority, there are no pending violations of any applicable building codes or zoning ordinances and there are no pending rezoning applications, hearings, cases, appeals, or other proceedings which could affect the zoning classification of this property. Sincerely, Thomas Perry, CBO Building Commissioner y ZAGZONING ANALYSIS GROUP, Ltd 1.012 NVT-K-a Stm,M-1,0xoma`ity,OK 7�11.4; 1 wtivwzag7,uning.cc1m 405 2, 4624. 1 fax,405242-4823 1 toll free.tOl 866 222.0219 1 tell frep fax 866,370.3635 To: Building From Brandy McGraw, InfcrmetiM Speoialist Fox., 50&790-6230 Pages. Phorx a 508-862-4038 Date: 04,118/2007 Re: CC: Cif Urgent ❑ For Review 0 Please Comment 0 Please Reply 0 Please Recycle I have attached a request for a zoning verification letter along with an old zoning letter that was provided to PZR. If you have any questions please feel free to give me a call. Thank you in advance for your help with this project, Regards, Brandy McGraw Z A AGZONING ANALYSIS GROUP, Ltd 10122'N.w I 819t Rmc.-t,olk-tc,�iojj.a Q.1ty,(")K 7311.4 1 wkvw Za9zolling.corn 4017.242,4821 ! f,,m 405.242-4823 pl"MA6,M6.222,0119 1 tvjj fr(.,e fa,,K Date.- April 18, 2007 To: Building Division Re, Request for Zoning Verification Letter for: The U-Haul Storage locate d 594 Bearses.Way We have been engaged to prepare a Zoning and Site Summary report for the above- mentioned site. Please consider this a formal request for a letter outlining the Zoning Designation and a Brief Description of the property, as follows, 6 What.is the current zoning of the property including any special, restrictive or overlay 0 Is this project part of a Planned Development? If so, please provide copies. ® Was this site developed oilth site plan approval'? if so, can we obtain a copy of it and/or the approval letter? a Was this properly granted any variances, special exceptions, or conditional use pexmits or zoning relief of any kind'? if so, please provide a copy.If these were not available., would you briefly outline the conditions of the applicable document? Q Are theTe any open zordug and bW.lding violaTions? Please provide as inuch information as possible on your letterhead find retuln by fax to $66370.3635 or etuail to the address below.Tease send a hard eo.py to the address above. Thank you.in advance for your time and consideration on the above matter. If you have any auestions or concerns, please do not hesitate to tali me at$66.222.0219. My email address is brandy.mcgra.w@zagzoning.con). Regards, Brandy McGraw, Information Specialist ...a G ZONING ANALYSIS GROUP, Ltd 1.012 NW 810 Street,Oklahoma City,OK' www,rrag on.i.n94oan tel.4105.242,4824 1 tax.405.24L4823 toll free tel.966.222.0219 1 tall.f ee fax Rh6.370;3635 Date: April 1 B, 2007 Re: Request for Certificates of Occupancy for the Shell and Tenants Information for: The U-Maul Storage located 594 Bearses Way To Whom It May Ooncem: Please provide copies of the Certificate of Occupancy search for the above project. Please contact me at 866.222.0219 it there is a fee. Please send copies to me via fax at 866.370.3635 and standard trail delivery. If you have any questions, do net hesitate to give me a call me. Thank you. Best Regards, Brandy McGraw, Information Specialist A ONING ANALYSIS C:iFt(UV, Ltd [()J2,V'4ti 81-st Street,Oldahorrua City,OK 1 i&rww 2 gzOI .Ig.COVI tel.4W242.4824 1 fax.405.242.45;3 i to)' tn^e.tel.866 222.0219 tall�xee fax&663'90.3b35 Date: April 18, 2007 To: Building Division Re: The t_1--Haul Storage located 594 Bearses Way Based on our records: __A valid certificate of occupancy has been issued and is now outstanding for the Project. For any certificates of occupancy not found, absence of a certificate of occupancy for the Project will not give rise to enforcement action affecting the Project. (See attached copies issued) Certificates of Occupancy for projects constructed prior to the year. ate no longer on file with this office. The Project was constructed in _ _. The absence of a certificate of occupancy for the Protect will not give rise to any enforcement action affecting the Project.. A certificate of occupancy for the Project will only be required to the extent of any construction activity (such as restoring, renovating or expanding the Project or any part thereof.) We are unable to locate a certificate of occupancy for the Project from our records. We have evidence in our records; however, one was issued and has been subsequently lost or misplaced. The absence of a certificate of occupancy for the Project will not give rise to any enforcement action affecting the Project. A certificate of occupancy for the Project will only be required to the extent of any construction activity, restoring, renovating or expanding the Project or any part thereof. The site is still being constructed. The absence of a certificate of occupancy for the Project will not give rise to any enforcement action affecting the Project. A certificate of occupancy for the Project will be issued when all final inspections have been passed. Please call the undersigned if you have any comments or questions. Sincerely, Name, Title: Phone: i I ZAGZONING ANALYSIS GROUP, Ltd 1012 NJW 8Ist Street,OfdahaiTi.a 0-v,OK I tel.405.242.024 i fix,405.21,21.4823 1 tc,11 frce.t,21,866.222,0219 I toil free fax 866.37'j.3635 Certificates of Occupancy Issuance Town of Barnstable, MA We have been engaged to prepare a zoliing report with regaid to the above site. As part of this report. it is our standard practice to include,answers to the following questions so that we inay accurately de-tern-tine the status of occupancy on site. I How does the City Issue Certificates of Occupancy for: (� lea,ve circle une) Single Tenant Buildings: Shells Tenants. Both Multiple Tenant Commercial Building: Shells Tenants Both Apartment Complexes Shells Tenants Both Shopping Centers: Shells Tenants Both Mobile Home Parks Shells Tenants. Both 2. When is a New Certificate of Occupancy required for., (please circle tine for each) Single Multi-Tenaut Apartments Shopping Tenant Commercial Complexes Center Change of Use yes no yes no yes no yes no Change of Owner yes no Yes n.0 yes no yes no Change of Tenant yes 110 yea no yes no yes no Tenant Improvements yes no yes 110 yes 110 yes no Renovationsf.Remodels yes no yes no yes 110 ye5 .1.10 MOBILE HOME PARKS--Change in Use yes/no , Change of Owner yes/no,Change of Tenant yes/no ,Tenant Improvem.ents yes/no Renovations/Remodels,yes/no 3. If a Property does not have a Certificate of Occupancy on file,would that put the Property in violation? (please circle) yes no 3a. if ves,what would need to be done to take care of the violation? 4. How long bas the City been Issuing Certificates of Occupancy? 5. Bow far back do your records go for: Certificates of occupancy Building Permits wM 6. ,Are your records kept on; (please circle all that gppl y and how far records go back) Computer: —_— ---- Paper:_ x'Vficxofi.l;aa: 7. ]Does the Building Department perform annual Building Inspections? yes no (Please circle) 7a, if not, does the Firc Department perform annual inspcetions? yes no (�Iease circle) Thauk.you io.advance fo.-your time and consideration Lin the above matter. If you have any questions or concerns,please Flo not;Hesitate to telephone at the toll free nu.mbe.r above. Sincerely, By: Printed Name: Title: (Title of Govemnaent Official) Town of Barnstable Regulatory Services ° `AM Thomas F.Geller,IDirettor P Ih Building Division Elbert C Ulshoeffer,Jr. Building CounrAssioner 367 Main Strsct, Hyannis,MA 02601 Office: $08.862-4038 Fax:. 509-790-6230 February 6,2001 Bukola Kongi The PlantuAgg&Zoning Resource Corporatiatt 25 South Ok]aho=A,venve Suite 300 Oklahcroa City,CiK 73104 , Re: Your recVaest for infarnistion regarding 594 Reuses Way,Ely-arims!(.r-klaul CF Dear Bukola Kongj, ® In respoase to your request concerning the above mentioned property's compliance with applicable codes, regulations and ordinances please be advised as follows: (I)The Building Coranissioner is responsible for effoTcetnent of building codes and zoning ordinances relaced to developtateut within the'Town of Sarmtable,Barnstable County,MA. (i)The prapErty is located in a B zone as indicated in attached documents wiiich provide for the existing uses as indicated oa the attached building permit and Certificote of Occupancy. tt[iJ l0 die best of my lmowledge auLl wj,.Wiz my auL'oricf,Lere are flu pcs.'.�^�;Vl01d[tOti QSr any applicable building codes or zoning ordinances and there are no pending rezouiLr g appli ations,hearings, cases,appeals,or other proceedings which could affect the zoning ciassifieation of this properry. sincerely, Elbert C.Ulshoe Building Com sioaer Acra e4closures goto296a pFTHE Tp Town of Barnstable Regulatory Services BARNSTABLE, v� MASS. 3. Thomas F.Geiler,Director AlEO►��p Building Division Thomas Perry,Building Commissioner 200 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 April 23, 2007 Brandy McGraw, Information Specialist Zoning Analysis Group, Ltd 1012 NW 81 st Street Oklahoma City, OK 73114 RE: Your request for information regarding 594 Bearses Way, Hyannis/U-Haul Dear Ms. McGraw, In response to your request concerning the above mentioned property's compliance with applicable codes, regulations and ordinances pleased be advised as follows: (I) The Building Commissioner is responsible for enforcement of building codes and zoning ordinances related to development within the Town of Barnstable, Barnstable County, MA. (ii) The property is located in a B zone as indicated in attached documents which provide for the existing uses as indicated on the attached building permit and Certificate of Occupancy. (iii) To the best of my knowledge and within my authority, there are no pending violations of any applicable building codes or zoning ordinances and there are no pending rezoning applications, hearings, cases, appeals, or other proceedings which could affect the zoning classification of this property. Sincerely, Thomas Perry, CBO Building Commissioner f .. r. TOWN OF BARNSTA$LH CERTIFICATE OF OCCUPANCY.-,-STORAGE ROOMS PARCEL ID 293 046 GBOBASB iDOb49y s Y= ADDRESS 594 BEARSE'S WAY PHONE HYANN I S ZIP - LOT 6 LC271 BLOCK - - <_'y0T SIZE DBA DEVEL&MENT `--- _ -- - -- DISTRICT HY PERMIT 47965 PERMIT TYPE BC00 TITLE CERTIFICATE. OF -WILE iPANCY CONTRACTORS: -.-- ---' -- , -- -�--__�.: ..� ... ARCHITECTS: _ _ Department of Health, S; - Environmentai 5erv: TOTAL FEES: Im BOND $_.00 CONSTRUCTION COSTS $_00 756 CERTIFICATE OF OCCUPANCY- AIVATE :P E -- . _ . • BI I1grABLF. o •�i. -r.a•. BIJJII.D MS DATE ISSUED 08/10/2000 -:; IRATION :IIAT =_ -. , 273294131- J O I � I 4 272 293 31,1 _. 7 1 12 92301. a M� , J � ) O > 9 O • sS 5, •. 1=I ru ,:,, 1 ";I ryi f:�,: �.. ,:. ra ir.�:, i '� 'i yJ t�,�jrl: 11a I fi(is" O Yi a I': aq� �;...,.. .: d 'l: �.,�: ..• .�;<" ..';.'.�.. Y� .,.; .,x'. ._. •: 2 � fr``Xp..��l.�Y`ali b�l2+JI Ida,{y. 1•? t .rtJ� ,� I ::..x;. ; :,7, ,I N,-1:.... ., :. .. .....a:. , 1..., t... :..a..,, F:. :..... ':. ;..�Nr p•I ii'.. :��n' G,�t 61 -!f �: ,, :., ... .: .,..... <.,.::.... -r: ..a ".f'` I J: sa:., t X.:.... '• f sc. 131:f?I�881: � f. :�. {t. ;-ir a....,4N .•. t.. :,.E4:R:.; fx ...: q_ ,,... ..:Y+•.:: ..,:,,. '' 7.. ,..--x ..,,:.. :..,... d�I, a. II .:1 9 t�ti. r :k� a. _.` � dd ..:'G. ,. ::i.. '.:r..,]. 4 .::' .Ix 4., .,<..,,...>•.. ..,!X s.:.'. !.:,. Ir,,'�'. ,ji a r tt.:'.,:'s ,,: � '�tl': ;,. :. n.,<.. .....1. r'l ..: ..:. .•�. ,;•,y 'I'"q 11�,r,...l.,Y. wY z,.:� � ��' i it ..:.:<. 1, :... '..1.:�..#,»., .:I'b ,,....:. ..K}.. ,. .-..,. .fw £.! ;. _c. 'S r .... 9: ,SI 11£i h;Ir .ni I. �„ 'F. :i,�,9 '.1. 'ta 5'x L,of 5• I YF . ,N.�:M ....i'.3} a l ,.. Y,.I�H ,� R..., .: ,, C' , .... ,.. y.ry.. { � ,,: :,v,": 3. .,.q:.. S:; ., ...., fil� .]. , i J, ��$I• �Ief '4 f'1, Y..fll ..4 I .9 5.. .. .il . .... ... ,I,f.. q•IJZ,. .,:.,.i.. i ...r. c:l is f,J- ..N ,.1. 1' � 'I. �I.,. �: I� N. tI': ..� .... .. :, ,.:s •... �il i. 1,r ...... ..: .r:_ :. ...., .. ,.. 4+. .,,.,„,.r,, hr,. yy .1. fd.;f� Y "N��! I Y „::,.,.. ••I ,, . ,�,!a i,� , ::.s. »..., ,.,. ,... L.,{ s..<,. t , ., .....1n :, I ri.Ml +, �'�I .314, �' i -� K tifr i a,h S �♦ . , ,'r+ , I d YI}�< �;E� �! '� �.. i t x�. ;t II .I 1 N i�l .� t Y� r!15J �V.axs. ':i •� 0.,,�':.. .�.v,. , I ,,,. ..,+...�, :r.Q. .:- 1: ......:. :...... .. •,. ,. .:, ,.e5+ :,:.-s .,,M-,. .' ,�, I '�i. i xr' �'AI-' ,IS P.;.. :�: 5 at W ,+.1-.: i .� I .:N. � .r. i;.:t,..�,. i r ��. d ut, q {"1 :4,.:.• 'd r i'::' ':.' :.,� 11"SpL�' .,;i.: t ''� 5 .<.,<• // ''. �� :ir ,ih i .r', )�`' S.:;h,uf'.. R, 1 Z G1 �:r ".� . ;,;..:. J+ ,t,AL z:•o � �k:.,.. ..;r 1 `": .t .: :.-, 1•' s S:':z ,1�.,F rn.�.Y, ] � ..� n� :•'�,� ., Or L� i� I m�.,_r.. f-,: i :� '9::r� , i,, a? .., ..r4,•tr,S,. �'d'4: �'aa�� e .L i t,. R r, 4s N �• e, b b,e2 ,ary.+t.1;��9 1 I. p .. : ..1�'.. ier ?,�: ,..�, a*^a� s .c' o '.4 c,, :.•'4'�{.a' 4di� {' an r. �75` a:.1 '(;!%I,JGeF' I. <ua,.P �� 1„ ,a 't;ti:3 � II '1,• C' ;ib`' Jikt .-Y, �h l�:'A:t1 I: .!Y 3'. 1. ry, '4. ,:7. •:.:z'. 511, I '� J•5 ,.. -x� �, ti. I�h 1. _G„. .:a.. •.r. '�l �I'� ifl,� d-� 'N'{ ,�gg .I �. - .fG'�1 ( d:`.:. "•,,.F i � ;:Ie^FH•I I tl, fr` 1 � :rV.'{i1. 1: � 1!� ,��' �/Lfi..h a ''_N•a �<E:, N;'"4' :.y >�'��!;� .., � fyI �,,,.... ..n ;.. .%. Pta4""'ki t:. h z,:. .�!'. .J�,, .'.,:.... _. pr. # q> 3,,.,. .:..:..:.:.. :. .._, -: 6,:,,.. _.,.f.. i•'.:;I... � 1 t, L a•1& 1 ryN4 I„7` OR17•.. .0 r,5f.��.,l .. ,,5;,. 1 -,.'t�i ,:;.t :. ,..,,.. , �?"� -.«:•t:: .x,...: �I r{.IR % bl:.I- h.}:47.. MR $ q„ ` 1 �p• ., •< #' .41 h I R JS ..:: .I I I C trJ `:'.M < •'i v I J4 �1 c <� ar '... :. r� ':. .. ,.. ;:....,;,•,. ,: .r.,. .. 1.:, ;:.. .._. �:: a '''+3 3•. ^��.. J ..3c. { r .a i.L.b 3 fIL }h: .,,. ,x, .,. ,,, ..... •. u6 p" ..:,,;1' .: S:it .1:.,. .li.;. F 3, ''�"� a ,{- '116 ."'. Oh, ;;t[ ,>`: �: :,�f: � 4 1. , S•t'.;r :Y ..• e _,,.. <.,.. :.., ` s •.� ) 1 i .., � ,, :;r .,,.6 Pr�3 +,+7 '3�:iv..1 '�...�•t `} :a....r r....t., .. �:., s;?. �.,,:„ :��, _ tq z: .. St.>x. _.. ',:.hd- +!ipp :3;. ._.r'"*..r,>..a "(•:.A.� ,, .,.F .F.,,., .. ..., 'R.: ��5: ti - It 1 1• .>. � 'i_h.,. a ,>;:. ,•}• Sw:; �. .; '05..t- r :.� ., _'aS. _.. x,- :�xl•. :.i £ q y�. '..,f Nb�J '�,�.,..... _. _. .<,.. .�' :, '.. .:. .. 1>. ,.�7r*� x,Tl:_;:,... ,s,t „ r' :>" 'C �:•.1i.✓ , ... �:�i ?: •=; 1,t .-::. ..: •`(LiL'. �:�; '[•�' v t rc'� a� Y ,,. � r.: .�� ... ..r f N. ... (;_. .q,;, T9 ..xz tl ax-.: r=.• '<,�..r ,.i. 41,•r, :4 �v t,'. , ry I� =la1.Y � fC s '�• ,r F :i.. s�f£3 3 { + .J,� .� �• 4 s t iS a r,S.t 5: :s« :'f;'. L .lu n vg � sa ::1>, • .a r�' �'s`� S s. \...a�� 'iu, . ; ..i y1 sn. f-• >.b x.� a i f. :'4.. < 4 R m4, •1a ^,:� .,4 x r;.:: .. R. �i,., /... ;"' a': .,<sr yr} :at s. ,t, :. ,,..;,I:r. 1.. �:.,t .♦ u:.. r.7-t.{.,fi !'fi,_ :4 't ,4'� �Jrl�f!+,{ w '�•Y>�•fr�x'4} ;�i:;.'::f .;, � �+rr F{�� ^��.�I I 'a� 4 rs' „}n" 3s'R.c d -� r� +� ,! li I I+ I. 'Y a d r 1 ,:� e�-r r a� a _ �,,Rx�$'I a l�}I t 1.. '.;�,. . y •Y �., � + HL�°d} Ir �� nilji. O \\n :'� ` •71 ( !4. �I li': )flll // \ 11/ IX 1!. -. •�• ��N .,' �F%�t � � I I(, Iir.N 1 .=3 � ` • ! 6` R �, .. t:F�XI 4- i� � � `� i� �!➢ � 1:.'t.,a i� 4 r ®``3 J �1s $ tt r.' .�. � � . � 5 { h �q/ Y s . W F .. re o d D , Assessor's map and lot number .... .......... JCL // 'p e Sewage Permit number �.7 ..lti ? .......... m`Q Z DAM STABLE, i House number \5�79V..... e4 ° ... i6}q. MAIL v Apo, �0 'Ep MAY O. TOWN . OF BARNSTABLE BUILDING =� IHSPECTOR APPLICATION FOR PERMIT TO ... TYPE OF CONSTRUCTION ....13/p f.............5 fee l.................................................................................... i TO THE INSPECTOR OF BUILDINGS: The undersigned hereby .applies for a permit according to the following information: Location .. .9 y......X e.Q C.`5:.... . .................................................................................. .. . ... . .... ProposedUse ..Lr`e. a�. ....... y.s.s........................ .............................................................................................:... Zoning District ...! ................................................................:Fire District .,./�� is.......�..!tP..... !.5........ ........ Name of Owner ...... ....... �.... .................Address ..(3F....H04',I,�...Bvio c�,wa�. ..E:.�l`}°.�:...�'�� Nameof Builder .......... C.........................................Address .................................................................................... Name of Architect •I.OYl1...�.....Ii.g. 1 olr� k...............Address 9w.7..7f.???,?k..51....w�li. Number of Rooms ..................................................................Foundation ..... _o.n.j:.FP f Exterior ....Q.'Y.I.C.ir.K:Ee,.....13.1Pc ... .. .......................Roofing .....57IIJ C'O�lS�ia.t, ,�.............................................................. Floors ...... .........................................................Interior ..................................................................... Heating ...... ...................................................................Plumbing Fireplace .Approximate Cost ......�o�l/llU............................................... Definitive Plan Approved by Planning Board ----------------------=--- ------�9-------- . Area Diagram of Lot and Building with Dimensions Fee -7.7..oa .1 ........... . . SUBJECT TO APPROVAL OF BOARD OF HEALTH ��X . � Pro ert S u-bons INC. A\� P Environmental & .Engineering Consulting 31 A Northfield Avenue Edison,:New Jersey 08837 732-417=0999�,Fax 732-417-0888. April 18, 2007, Freedom of Information Officer Barnstable Building Division 200 Main Street Hyannis, MA 02601 Re: U-Haul.of Hyannis, 594 Bearses Way. . Hyannis,Barnstable County,NIA 02601 Parcel ID: 293046 - Property Solutions Project#20071631 Dear Freedom of Information Officer: Property Solutions Inc. .is conducting a Phase I Environmental Assessment of the aforementioned property. As part of a property assessment, we wish to determine whether government agencies.possess records on the subject property that may include potential environmental concerns.. We request information on the following: • Outstanding building code violations • Permits for Underground or Abovegr_o'uiid Storage:"Tanks (UST/AST), installation or removal • bemolition/renovation permits If you have any questions, please call*.me at 732-417-0999 x 222 or email me at jkelly@propertysolutionsinc.com: If you have no information on the property, please fill in the box to the.right and fax back to me at 732-417-0888. Thank you for your assistance. Sincerely, ❑ No Files for.subject propertylor address Name: Title: GZ Phone: James Kelly Environmental Scientist XI T-v Date SERVING YOUR NEEDS NATIONWIDE FROM OUR OFFICES IN: PHILA NY CHICAGO LA DALLAS PORTLAND ATLANTA BALTIMORE TOWN ©V BANSTABLE • r' BUILDING FERMIT ;PARCEL ID 293 046 GE09ASE ID'` 20549 ADDRESS 594 BEARSE'S WAY PHONE i HYANNIS ZIP - I LOT 6 LC271 BLOCK LOT SIZE DBA DEVELOPMENT DISTRICT HY F PERMIT 47194 DESCRIPTION TO ADD 246 STORAGE ROOMS PERMIT TYPE BREMODC TITLE COMMERCIAL ALT/CONV CONTRACTORS: Department of Health, Safety ARCHITECTS:` and Environmental Services TOTAL FEES- $50.00 BOND $.00 OxINE ICONSTRUCTION COSTS $8,000.00 I ' 437 NONRES./NONHSKP ADD/CONY'-"I � PRIVATE P HARNsi'ABI.E. I MASS. 1639. `��► BUILD O B DATE ISSUED . 07/05/2000 EXPIRATION DATE I I THIS PERMIT CONVEYS NO RIGHT TO OCCUPY ANY STREET,ALLEY OR SIDEWALK`OR ANY PART THEREOF, EITHER TEMPORARILY OR PERMANENTLY. EN- CROACHMENTS ON PUBLIC PROPERTY,NOT SPECIFICALLY PERMITTED UNDER THE BUILDINGCODE,MUST BE APPROVED BY THE JURISDICTION.STREET OR j ALLEY GRADES AS WELL AS DEPTH AND LOCATION OF PUBLIC SEWERS MAY BE OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS.THE ISSUANCE OF THIS i PERMIT DOES NOT RELEASE THE APPLICANT FROM THE CONDITIONS OF ANY APPLICABLE SUBDIVISION RESTRICTIONS. i MINIMUM OF FOUR CALL INSPECTIONS REQUIRED FOR ALL CONSTRUCTION WORK: APPROVED PLANS MUST BE RETAINED ON JOB AND WHERE APPLICABLE, SEPARATE 1.FOUNDATIONS OR FOOTINGS THIS CARD KEPT POSTED UNTIL FINAL INSPECTION PERMITS ARE REQUIRED FOR 2. PRIOR TO COVERING STRUCTURAL MEMBERS HAS BEEN MADE.WHERE A CERTIFICATE OF OCCU- ELECTRICAL,PLUMBING AND MFOR (READY TO LATH). PANCY IS REQUIRED, SUCH BUILDING SHALL NOT BE ANICAL INSTALLATIONS. ECH- 3.INSULATION. OCCUPIED UNTIL FINAL INSPECTION HAS BEEN MADE. 4.FINAL INSPECTION BEFORE OCCUPANCY. i BUILDING INSPECTION APPROVALS PLUMBING INSPECTION APPROVALS ELECTRICAL INSPECTION APPROVALS I I i 2 2 2 I 3 . 1 HEATING INSPECTION APPROVALS ENGINEERING DEPARTMENT I 2 BOARD OF HEALTH 1 i OTHER: SITE PLAN REVIEW APPROVAL WORK SHALL NOT PROCEED UNTIL PERMIT WILL BECOME NULL AND VOID IF CqAS INSPECTIONS INDICATED ON THIS THE INSPECTOR HAS APPROVED THE STRUCTION WORK IS NOT STARTED WITHIN CARD CAN BE ARRANGED FOR BY VARIOUS STAGES OF CONSTRUC- MONTHS OF DATE THE PERMIT IS ISSUED TELEPHONE OR WRITTEN NOTIFICA- TION. NOTED ABOVE. TION. I .... � r............ I ��� Assessor's map and lot number ... T E F pOd 3 Sewage Permit number �.7� House number 'oo ,....... �� 2639. �®0 TOWN OF BARNSTABLE i BUILDING "': INSPECTOR APPLICATION FAR PERMIT TO ...L�rf. R........ 0......... 1��Si7i ....� �f!.��>r!.:k�....................... ...... c� s to e l TYPEOF CONSTRUCTION ..../..:.�.a...f................................................................................................................ .... l�:.'�. .......19..... TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: e.�t t.5 c.,.5........W . .............................................................................................................. Location ..` .9.y.......1 Proposed Use .e. � .. s.:.......................................................................................................................... �cl. r....... �• -yam . Zoning District ...!�...............................................................:Fire District .../�a. 1. .:5.......�fP.....!, ..!.5. �f.�:........ Name of Owner �...... ................r...............Address .3 .... .Q. 1, :.. �'OC? ►May. ..E:.�,`F°.�:...R� Nameof Builder .......... 1n1 ........................................Address ....................................................................................... Name of Architect loh1i `;..... It olr.0 k-..............Address .<e?.7....lem ?(. �T �✓�►i f l ct1't....mq.$5: Number of Rooms .........................Foundation ....C..A.n.5:t e- ..e Exierior ....Q.? -e�1CX-e .....56:o W.....................................Roofing ..... .. ............................. ...................................... Floors ...... C.:YIt t.t;{.e.........................................................Interior .................................................:.................................. Heating ...... ...........:.......................................................Plumbing .................................................................................. Fireplace Approximate Cost .....�o (/llU................................ p ............. ................................................ -----19--------• Area .... 34s tJ Definitive Plan Approved by Planning Board ----------------__________ ........'" ................ Diagram of Lot and Building with Dimensions Fee .........`7'.. 0� ................. SUBJECT TO APPROVAL OF BOARD OF HEALTH (� Lk-A v OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Name . ................... ....................................... Construction Supervisor's License Oze47 All...... 2ewage essor's ma and lot number �S. C �v3T �a�z c� _c .. Permit number ...�G.L� F� .:G�... �.....'.���` .... ....... Z 33AUSTABLE, i House number 900 "6}}9 ............................................................ TOWN OF BARNSTABLE BUILDING INSPECTOR APPLICATION FOR PERMIT TO ......... . : ..................... .... ....................................................... 1 TYPEOF CONSTRUCTION ........................... ��r. `��................................. .................................... ..Y.:. I`1........19 . TO"THE INSPECTOR OF BUILDINGS: h following information: 't acco rding to e The undersigned hereby applies for a perms g 9 9 Y P Location ........... ..1..../....... ........................................................................... ................................... ProposedUse .... 5. . .......1. Q.�°...�'.�� 1.:?►. ........ .1-..l�°�'X..(................................................................... Y, ZoningDistrict ....................... .......................................Fire District .............. ....... ...................................................... �� � Gfi/ Name of Owner .1� ......�°CI�. V'�a.. ....-�rk% .�4ddress ....5! .Al..... .... ...Gr/ ... .......... Name of Builder .... '! :1.I-%.. ...............Address ..... .................................................................................... .Name of Architect ..................................................................Address .................................................................................... ............Foundation ....................................................................... Number of Rooms ..................................................... ....... ��rit.K Exterior ..............................................Roofing ..............................................................,. Floors ............... (a.rT-e............,...........................Interior ........:'�`................................................................... Heating ........ �........... ... .:. ......................Plumbing ..................... .......................................................... I s Fireplace ..:............................. .................................................Approximate Cost ... . .. .�Q.:.../............................... Definitive Plan Approved by Planning Board ________________________________19_______. Area .........`................................. Diagram of Lot and Building with Dimensions Fee ...... ............................ .SUBJECT TO APPROVAL OF BOARD OF HEALTH I hereby agree to conform to all the Rules and .Regulations of the Town of Barnstable regarding the above construction. Name C"'�' ............... f I` A i � � J � ` �. J� f Town of Barnstable °^ Regulatory Services r r 9enRtvneKAM.tEg* Thomas F.Geiler,Director �A 1639�639. �0 rE +p Building Division Elbert C Ulshoeffer,Jr. Building Commissioner 367 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 PLEASE FORWARD THE ATTACHED PAGE(S) TO: TO: Bukola Kongi ATTN: FAX NO: 888-523-9008 FROM: Elbert C. Ulshoeffer,Jr. Building Commissioner DATE: 2/6/01 PAGE(S): / (EXCLUDING COVER SHEET) �PLEASE NOTE ZONING CORRECTION;IN-�PARAGRAPH 3 OF ATTACHED LETTER—PROPERTY-IS,IN'ZONE`B'�NOT:HB. f °Ft► , Town of Barnstable ti Regulatory Services iARNSTABLE.A Thomas F.Geiler,Director 9�A 11K6A3S99. lEDnw't°i Building Division Elbert C Ulshoeffer,Jr. Building Commissioner 367 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 February 6,2001 Bukola Kongi The Planning&Zoning Resource Corporation 25 South Oklahoma Avenue Suite 300 Oklahoma City,OK 73104 Re: Your request for information regarding 594 Bearses Way,Hyannis/U-Haul Dear Bukola Kongi: In response to your request concerning the above mentioned property's compliance witli applicable codes, regulations and ordinances please be advised as follows: (I)The Building Commissioner is responsible for enforcement of building codes and zoning ordinances related to development within the Town of Barnstable,Barnstable County,MA. (ii)The property is located in a B zone as indicated in attached documents which provide for the existing uses as indicated on the attached building permit and Certificate of Occupancy. (iii)To the best of my knowledge and within my authority,there are no pending violations of any applicable building codes or zoning ordinances and there are no pending rezoning applications,hearings, cases,appeals,or other proceedings which could affect the zoning classification of this property. Sincerely, Elbert C.Ulshoe Building Co sioner' /km enclosures g010206a Town of Barnstable Regulatory Services r BARNSPABLL ' Thomas F.Geiler,Director mass. 94'prEp .,a`�� Building Division Elbert C Ulshoeffer,Jr. Building Commissioner 367 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 February 6,2001 ti �1 Bukola Kongi The Planning&Zoning Resource Corporation 25 South Oklahoma Avenue Suite 300 Oklahoma City,OK 73104 Re: Your request for information regarding 594 Bearses Way,Hyannis/U-Haul Dear Bukola Kongi: In response to your request concerning the above mentired p perty's compliance with applicable codes, regulations and ordinances please be advised as follows: (I)The Building Commissioner is responsible for forcement of b 'Iding codes and zoning ordinances related to development within the Town of Barnstable,Barnstable Co ty,MA. (ii)The property is located in an/ich ' dicated in attached docum is which provide for the existing uses as indicated on thding permit and Certificate o ccupancy. (iii)To the best of my knowledmy authority,there are no pendin violations of any applicable building codes or zos and there are no pending rezoning applications,hearings, cases, appeals, or other proceeduld affect the zoning classification of,this.property. Sincerely, \\` ., Elbert C. Ulshoeffe Building Commissioner,../ /km enclosures g010206a TO ALL NEW BUSINESS OWNERS DATE: 3• •O ,. Fill in please: I11XM vgft a APPLICANT'S � � YOUR NAME:ft _ BUSINESS "v10 ` YOUR HOME ADDRESS: TELEPHONE ^ Telephone Number Home NAME.OF NEW BUSINESS 1_ c7 TYPE OF BUSINESS IS THIS A HOME OCCUPATION? YES N Have you been given approval from the bui mg division? YES P. ADDRESS OF BUSINESS `a' MAP/PARCEL NUMBER When starting a new business there are several things you must do in order o be in compliance with the rules and regulations of theTown of Barnstable. This form is intended to assist you in obtaining the information you may need. Once you have obtained the required signatures, listed below,you may apply for a business certificate at the Town Clerk's Office (Ist floor-Town Hall). You MUST go to the following office to make sure you have all the required permits and.licenses.. GO TO 200 Main St. - (corner of Yarmouth Rd. & Main Street) and you will find the following offices: 1. BUILDING COMMISSIO 'S OFFICE.. This individual h en info me of any.permit requirements that pertain to this type of business. Aut orized Signatur COMMENTS: 2. BOARD OF HEALTH This individual has bee inf.rmed of the permit r irements that pertain to this type of business. horized Signature COMMENTS: 3. CONSUMER AFFAIRS (LICENSING AUTHORITY) This individual has been informed of the licensing requirements that pertain to this type of business. Authorized Signature** COMMENTS: Business certificates (cost$30.00 for 4 years). A business certificate ONLY REGISTERS YOUR.NAME in the town (which you must do by M.G.L. -it does not give you permission to operate-you must get that through completion of the processes from the various departments involved. **SIGNIFIES APPROVAL FORA BUSINESS CERRF/CATE Oft Y. 4• ' i o Ol' ael '' �oa tom, d �aaaac�ti�ae fie Dme-loxe Deval Patrick c/llQi ���///G/�/JG Mary Elizabeth Heffernan Governor Secretary TimothyMurray7J /6�j/1P�OD19 Y Thomas G.Gatzunis,P.E. Lieutenant Governor / Commissioner 01/10/2012 VIA EMAIL: linda.hutchenrider@town.barnstable.ma.us City/Town of Barnstable To Whom It May Concern: Pursuant to M.G.L. c143 §65 this serves as notice that the elevator(21-V-320)located at 594 Bearses-W-ay,-Barnstable has been deemed unsafe by an inspector at the Department of Public Safety for the following reasons(s):Unsafe,stress fractures on the platform welds. This is for your information only as required by statute and no further action is required. Sincerely, Elevator Division Department of Public Safety ' YOU WISH TO OPEN A BUSINESS? For Your Information: Business certificates(cost$40.00 for 4 years). A business certificate ONLY REGISTERS YOUR NAME in town (which you must do by M.G.L.-it does not give you permission to:operate.] You must first obtain the necessary signatures on this form at 200 Main St., Hyannis. Take the completed form to the Town Clerk's Office, 1 st FI., '367 Main St., Hyannis, MA 02601 (Town Hall) and get the Business Certificate that is required by law. DATE: 9 7 2a Fill in please: - APPLICANT'S YOUR NAME/S: I M ...BQSINESS YOUR HOME ADDRE 2 1u 6 "`�s ��cK s ue' �rVY1�1 4� cb� 7�/-5 i�>v ;��� CtSS : 1°� •6ck975 Ftxrrts �-iG . w� z�Cs[� TELEPHONE # Home Telephone umber 6 o$— -7 -9`)to k NAME OF CORPORATION � o�[S NAME OF NEW BUSINESS TY 'thF.BUSINESS, Z r IS',THIS A HOME OCCUPATIQN� YES '' N ✓ 1 MAP/PARCEL NUMBER`.Zol cll� L. ' ADDRESS OF BUSINESS' cc T Lp'.[AssesIs ng),F . When starting a new business there are several things you must do in order to be in compliance with the rules and regulations of the Town of Barnstable. This form is intended to assist you in obtaining the information you may need. You MUST GO TO 200 Main St. - (corner of Yarmouth Rd. & Main Street) to make sure you have the appropriate permits and licenses required to legally operate your business in this town. 1. BUILDING COMMISSIONER'S OFF IC This individual has informed ny permit requirements that pertain to this type of business. uth razed Sig atu zc .a COMMENTS: Q rC c-� �J 2. BOARD OF HEALTH This individual b en inf m of the perm' equire nts that pertain to this type of business. Autaori 6 � NWITHALL COMMENTS: 2.,. 3. CONSUMER AFFAIRS(LICENSING AUTHORITY) This individual has n r ed o the lic sin qwr that pertain to this type of business. A Authorized Signature** COMMENTS: TOWN OF BA IN SABLE ` BUI-LDI.Nri, PERMIT PARCEL ID 293 046 GEOBA SE ID ' 20549 ADDRESS 594 BEARSE'S WAY PHONE HYANNIS ZIP LOT 6 LC271 BLOCK LOT SIZE DBA DEVELOPMENT DISTRICT HY PERMIT 47194 DESCRIPTION TO ADD 246 STORAGE ROOMS PERMIT TYPE BREMODC TITLE COMMERCIAL. ALT/CONV CONTRACTORS: Department of Health, Safety ARCHITECTS: and Environmental Services TOTAL FEES: $50.00 BOND $.00 CONSTRUCTION COSTS $8,000.00 437 NONRES./NONHSKP ADD/CONV�.k PRIVATE PF Ea«. ; * BARNSTABLF, MASS. 039. �ED \„7 BUILDI�T.G B , . DATE ISSUED 07/05/2000 EXPIRATION DATE SOWN o-0Y. BARNStABSE BUILDING PERMIT I PARCEL ;'ED 203 046 _ GEO: aE.*I 2054 ADDRESS • 594 BEAR, 'S WAY f PHONE HYANNIS ,. ZIP L01, .t B LC271 BLOCK �,`. LOT SIZE DBA DEVELOPMENT DISTRICT HY , PERMIT 47194 DESCRIPTION TO ADD 246 STORAGE ROOMS PERMIT TYPE BREMODC TITLE COMMERCIAL ALT/CON CONTRACTORS:.f Department of Health, Safety ARCHITECTS:" and Environmental Services TOTAL FEES: $50:00 SINE BOND _ $.00 COSST RUdTION COSTS $8,000.00 �Y Qi► I 1437 NONRES /NONHSKP AD°D/CONV'`,1 PRIMATE P�', *P" STABLE, . h� 4 MAS&` 9. ` BUILDI.�T,Q > 'Ii.IO DATE. ISS' ED 07/05/2000 EXPU ATION DATE THIS PERMIT CONVEYS NO RIGHT TO OCCUPY ANY STREET,ALLEY.OR SIDEWALWOR ANY PART THEREOF, EITHER TEMPORARILY OR PERMANENTLY. EN'- { CROACHMENTS ON PUBLIC PROPERTY,NOT SPECIFICALLY PERMITTED UNDER THE BUILDING CODE,MUST BE APPROVED BY THE JURISDICTION.STREET OR ALLEY GRADES AS WELL AS DEPTH AND LOCATION OF PUBLIC SEWERS MAY BE OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS.THE ISSUANCE OFTHIS PERMIT DOES NOT RELEASE THE APPLICANT FROM THE CONDITIONS OF'ANY APPLICABLE SUBDIVISION RESTRICTIONS. MINIMUM OF FOUR CALL INSPECTIONS REQUIRED FOR ALL CONSTRUCTION WORK: APPROVED PLANS MUST BE RETAINED ON JOB AND THIS CARD KEPT POSTED UNTIL FINAL INSPECTION WHERE APPLICABLE, SEPARATE 1,FOUNDATIONS OR FOOTINGS PERMITS ARE REQUIRED FOR 2. PRIOR TO COVERING STRUCTURAL MEMBERS HAS BEEN MADE.WHERE A CERTIFICATE OF OCCU- ELECTRICAL,PLUMBING AND MECH- (READY TO LATH). PANCY IS REQUIRED,SUCH BUILDING SHALL NOT BE ANICAL INSTALLATIONS. I 3.INSULATION. OCCUPIED UNTIL FINAL INSPECTION HAS BEEN MADE. I 4.FINAL INSPECTION BEFORE OCCUPANCY. I I BUILDING INSPECTION APPROVALS PLUMBING INSPECTION APPROVALS ELECTRICAL INSPECTION APPROVALS I I 2 2 2 I 3 1 HEATING INSPECTION APPROVALS ENGINEERING DEPARTMENT 2 BOARD OF HEALTH i OTHER: SITE PLAN REVIEW APPROVAL � I I 1 WORK SHALL NOT PROCEED UNTIL PERMIT WILL BECOME NULL AND VOID IF CON- INSPECTIONS INDICATED ON THIS . THE INSPECTOR HAS APPROVED THE STRUCTION WORK IS NOT STARTED WITHIN SIX CARD CAN BE ARRANGED FOR BY I VARIOUS STAGES OF CONSTRUC- MONTHS OF DATE THE PERMIT IS ISSUED AS TELEPHONE OR WRITTEN NOTIFICA- TION. NOTED ABOVE. TION. I I II rn - av � v . � _ - z f P�oFt rq��o Town of Barnstable Regulatory Services Thomas F.Geiler,Director MAss. 1639. � Build.ing Division Tom Perry, Building Commissioner 200 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 Date r Address To Whom It May Concern: Our attention has been alerted to the fact that you are flying illegal contrary to the Town of B arnstable's Zoning Ordinances.The Town has a sign code which is explicit regarding flags. Section 4-3.3,Prohibited Signs(1)"Any sign,all or any portion of which is set in motion by movement, including pennants,banners or flags,except official flags of nations or administrative or political subdivisions thereof." Please contact me at 508-862-4033 when these flags have been removed so that I can inspect the site.Thank you for your anticipated cooperation. Sincerel , .,, David Mattos Building Inspector �i TOWN OF BARNSTABLE CERTIFICATE OF OCCUPANCY--STORAGE ROOMS PARCEL ID 293 046 GEOBASE ID 20549 ADDRESS 594 BEARSE'S WAY PHONE HYANNIS ZIP - LOT 6 LC271 BLOCK LOT SIZE DBA DEVELdPMENT DISTRICT HY PERMIT 47965 DESCRIPTION PERMIT TYPE BC00 TITLE CERTIFICATE OF OCCUPANCY CONTRACTORS:. Department of Health, Safety ARCHITECTS: and Environmental Services TOTAL FEES: THE BOND $.00 ' CONSTRUCTION COSTS $.00t 756 CERTIFICATE OF OCCUPANCY 1 PRIVATE P]£;.i*►f'3 41 1 * BARNSTABLF, • MAS& 3939. A� FD MI�►� BUILDING'DIVISION, j BY DATE ISSUED 08/10/2000 EXPIRATION DATE TOWN OY-BA:RNST.ABLE CERTIFICATE OF 7 U ' NAY-- -$'TORAGE ROOMS PARCEL ID 29$ 04B GEOnA 9-gID 20 45 ADDRR`SS 594 BEARS:'S WAY � PHONE RYAN fIs ZIP LOT 6 =271 BLOCK LOT' SIZE. DI3A DEVEL6PMFNT DISTRICT BY PERMIT 47965 DESCRIPTION PERMIT TYPE ; BCOO TITLE' CERTIFICATE OF OCCUPANCY CONTRACTORS: Department-of Health, Safety ARCHITECTS: and Environmental Services TOTAL FEES: Ox THE . BOND $_00 � �► CONSTRUCTION COSTS $_00 756 CERTIFICATE OF OCCUPANCY IPRIVATE ,P:" *1 :rp . ..,STABLE. MASS. �039. ED Mid _ � I BUILDING;�DIVISIO BY 1 DATE ISSUED 06/10/2000 EXPIRATION DATE THIS PERMIT CONVEYS NO RIGHT TO OCCUPY ANY STREET,ALLEY OR SIDEWALK OR ANY PART THEREOF, EITHER TEMPORARILY OR PERMANENTLY. EN- CROACHMENTS ON PUBLIC PROPERTY,NOT SPECIFICALLY PERMITTED UNDER THE BUILDING CODE,MUST BE APPROVED BY THE JURISDICTION.STREET OR. ALLEY GRADES AS WELL AS DEPTH AND LOCATION OF PUBLIC SEWERS MAY BE OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS.THE ISSUANCE OFTHIS PERMIT DOES NOT RELEASE THE APPLICANT FROM THE CONDITIONS OF ANY APPLICABLE SUBDIVISION RESTRICTIONS. MINIMUM OF FOUR CALL INSPECTIONS REQUIRED , FOR ALL CONSTRUCTION WORK: APPROVED PLANS MUST BE RETAINED ON JOB AND WHERE APPLICABLE, SEPARATE 1.FOUNDATIONS OR FOOTINGS THIS CARD KEPT POSTED UNTIL FINAL INSPECTION PERMITS ARE REQUIRED FOR 2. PRIOR TO COVERING STRUCTURAL MEMBERS HAS BEEN MADE.WHERE A CERTIFICATE OF OCCU ELECTRICAL,PLUMBING AND MECH- (READY TO LATH). PANCY IS REQUIRED,SUCH BUILDING SHALL NOT BE ANICAL INSTALLATIONS. 3.INSULATION. OCCUPIED UNTIL FINAL INSPECTION HAS BEEN MADE. j 4.FINAL INSPECTION BEFORE OCCUPANCY. ROM mi BUILDING INSPECTION APPROVALS PLUMBING INSPECTION APPROVALS ELECTRICAL INSPECTION APPROVALS J 1 I I �I 2 2 2 I 3 1 HEATING INSPECTION APPROVALS ENGINEERING DEPARTMENT 2 BOARD OF HEALTH OTHER: SITE PLAN REVIEW APPROVAL WORK SHALL NOT PROCEED UNTIL PERMIT WILL BECOME NULL AND VOID IF CON- INSPECTIONS INDICATED ON THIS THE INSPECTOR HAS APPROVED THE STRUCTION WORK IS NOT STARTED WITHIN SIX CARD CAN BE ARRANGED FOR BY VARIOUS STAGES OF CONSTRUC- MONTHS OF DATE THE PERMIT IS ISSUED AS TELEPHONE OR WRITTEN NOTIFICA- TION. NOTED ABOVE. TION. i i i i i C rn - , _ � r v � . _ Z :�#fir• � #a +.�Y ..f � �� h + � Si w,�y V fi � fir° t � ++ a. � .� �, �; w w. '+ ,u 7 r�yg �, h(,ktF i t '! ,t - .� r� to e r ,j ➢. { �.. .. � _ . .* f�� � a I ��``'�+$�'�. ^,�'� _ ; x . � is �:.� r, •ice .. �� v t� e'�i'4' sr �r's'"r �'" "r�'r'w,. �� ��< �, a #.' �� J` t: � �� � _. kY' �j`�' �y, p- � �' ,l y s �a ,� 1 �� � � r Pr �.;. w Q-�. y,P A i d 'SGS. �. ' t �,� � �� .�°� ��� � -_ _ _. .l f Town of Barnstable Regulatory Services mmsrABLE - Thomas F.Geiler,Director MAs,4� 1639.,, `�� Building Division Elbert C Ulshoeffer,Jr. Building Commissioner 367 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 February 6,2001 Bukola Kongi The Planning&Zoning Resource Corporation 25 South Oklahoma Avenue Suite 300 Oklahoma City,OK 73104 Re: Your request for information regarding 594 Bearses Way,Hyannis/U-Haul Dear Bukola Kongi: In response to your request concerning the above mentioned property's compliance with applicable codes, regulations and ordinances please be advised as follows: r (I)The Building Commissioner is responsible for enforcement of building codes and zoning ordinances related to development within the Town of Barnstable,Barnstable County,MA. (ii)The property is located in a B zone as indicated in attached documents which provide for the existing uses as indicated on the attached building permit and Certificate of Occupancy. (iii)To the best of my knowledge and within my authority,there are no pending violations of any applicable building codes or zoning ordinances and there are no.pending rezoning applications,hearings, cases,appeals,or other proceedings which could affect the zoning classification of this property. Sincerely, Elbert C.Ulshoe Building Co sioner /km enclosures g010206a Town of Barnstable Regulatory Services BARMARM ' Thomas F.Geiler,Director AjE1 59. Building Division Ralph Crossen,Building Commissioner 367 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 Attn. Bridgit @405-840-2608 Please find a copy of the CO and the Site Plan approval letter as requested. There are no complaints pending currently. Historic records indicate only very minor infractions. We find the manager to be most cooperative and all issues tend to be rectified immediately. At this time, there are no unresolved violations pending. I hope this satisfies your request. ZBA issues are addressed by Planning. The ZBA clerk (Sheila) can be reached at 508-862-4785. I forwarded a copy of your request to the Planning Department on 9/14. Please call me if you require additional information. r t The Town of Barnstable Department of Health Safety and Environmental Services • M&MABMMAM ; Building Division 1659. 367 Main Street,Hyannis MA 02601 Office: �508-862-4038. Ralph Crossen Fax: 508-790-6230 Building Commissioner May 14, 1998 Bob Bolton U-Haul Company 738 North Broadway East Providence, R.I. 02914 Re: SPR-033-98 U-Haul, 594 Bearses Way, Hyannis (293/046) Proposal: Install.self storage units. Regrade and upgrade drainage of existing facility. Revised plan dtated 517198. Dear Mr. Bolton, The above referenced proposal was reviewed at the Site Plan Review Staff Meeting of May 14, 1998 and approved under Section 4-7.4 (2) of the Barnstable Zoning Ordinance with the following conditions: • Resolution of location of hydrant. • Trees to be planted along Bearses Way. • Connection to town sewer when it becomes available. Enclosed is you signed plan. A letter has been sent to the Cape Cod Commission which states that this does not trigger a Development of Regional Impact(DRI) referral. Please be informed that a building permit is. necessary prior to any construction. Upon completion of all work, the letter of certification required by Section 4-7.8 (7) of the Town of Barnstable Zoning Ordinances must be submitted. Also, all signage must be discussed with Gloria Urenas of this Division. Should you have any questions, please feel free to call. Respectfully, Ralph Crossen Building Commissioner TOWN 0E'-BARNSTAl3LE � s CERTIFICATE OF OCCUPANCY- STORAGE ROOMS PARCEL ID 293 046 GEOBASN ID ADDRESS 594 BEARSE'S WAY PHONE HYANNIS ZIP - LOT 6 LC271 BLOCK •.i:-. - =~r�"•=._'LOT SIZE DBA DEVELOPMENT DISTRICT HY PERMIT 47965 DESCRIPTION -' -- PERMIT TYPE HC00 TITLE CERTIFICATH OF ,QC FANCY CONTRACTORS: ARCHITECTS: Department of Health, S, EnvwonirientaI Sery TOTAL FEES: BOND $_.00 THE CONSTRUCTION COSTS $.OQ 756 CERTIFICATE OF OCCUPANCY- -PRIUATB P i E 90 '$fjmD s IVIS By - - DATE ISSUED 08/10/2000 -,; MWlRA=— N :IIATBw= : _.:- Assessor's map and lot number ....... .. .' ........... ��Qypi?ME T��♦� Sewage Permit number ..G1//v!�A�GI Y�'ri(........... 3 Z BARNSTABLE, i s9yHouse number .;......., 9°0 M639 0 MAN a. TOWN OF BARNSTABLE BUILDING "INSPECTOR APPLICATION FOR PERMIT TO ... R:......... .........` � i7i .....l �f.!.��%u................................ TYPEOF CONSTRUCTION ..../..:.3....................................................................................... 417 M TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: Location `�9 y .l e.R. SS.�S........ �j............................................................................................................... ProposedUse ..c e a�.r.......� ......................... .................................................................................................. • •yam . Zoning District :Fire District a.-n.�!.'S �fP '*Z{:s1`�i�. •�...................................�................... l h. ......f.. ....... Name of Owner .C'1 µ�......k.......1�.... ...............Address .... .Q.� T. ....'�? !.wc: . ..E:.IZ}u j/; [��• Nameof Builder ..........YQ `........................................Address .................................................................................... Name of Architect ............ � .l.Q... Address .9d..7. Number of Rooms ..................... . ............. 4.. ........................Foundation .... A3'.� FPT e.................................................. / .C4�1S ..a`.41. ?...........................Exierior n11 c . .............Roofn ..... .... ....... . Floors ......CA. '1 !.4 ..4.........................................................Interior .................................................................................... Qr Heating .....T?.,�>...................................................................Plumbing .................................................................................. Fireplace .Approximate Cost .....o ��U................................ Definitive Plan Approved by Planning Board __________________ _________19--------. Area Diagram of Lot and Building with Dimensions Fee ...........7 ./.0 ^ ................. i SUBJECT TO APPROVAL OF BOARD OF HEALTH OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Name ................... ....................................... Construction Supervisor's license .(..r ..9...... From:BrgitKing To:Robin G.angregono - - - ®� THE PLANNING be ZONING RESOURCE CORPORATION ® / 25 SOUTH OKLAHOMA AVENUE, SUITE 400 • OKLAHOMA CITY. OKLAHOMA 73104 TELEPHONE (405)840-4344 • FAx(405) 840-2608 TOLL FREE (800) 344-2944 To: Tohn of Barnstable Attn: Robin Gianeregorio Fax: 508.790.6230 Date: October 5,2000 Subject: Zoning Verification Letter for: U Haul-.594 Bearses If,"qv I am checking the status on the zoning letter requested back on September 13th. Please let me know. as soon as you can, when I will be able to get the letter. If we can at least get what the zone is, in writing,that would be great! Please call. Thank you for vour tune and consideration on the above matter. If you have any questions or concerns.please do not hesitate to give:pie a call at the toll free number above, extension 619. Sincerely,: Brigit Kuig NATIONAL PLANNING ZONING CONSULTING SERVICE f 10/10/00 Attn.:Brigit King i Re: 594 Bearses Way(U Haul) ma depicting the subject property(see am faxing you a co of the zoning p p g J I g y PY B is the business zone. A small comer of the subject lot appears to be located in the RC-1 zone which is a residential district. I have been on vacation,so please excuse the delay(or redundancy if someone else answered in my absence). ;a u o 27 272 293 311 !•- o :. 271 292 310 .T 'i-. .S't ... ,.� '. :: � � �.':. ';.: kt4 � -y:F,K��,3�`� : r�1,iY � �'.A,� ua��}4.. �•. k i :�Y �"•F. .,.. .r.:: .�.:'.r,,, y. .;��,. y:. f �9E�'?�.,�I .r t}tr�f. iJ M.�l' �. .,��•q �t t ��a� �ui.0 7 ... :, .. :... -... a.>. �: -:i -{- c,f1 -.. ,}.n!', c' �,a...`. 'ems':?„..Is^• .;.�§?.. w:. 2�. 1..,} : r mn -1 1=.'.•� i` �..: �� .,..,::'._ �.;' �M :fir � �. ?,>.'<u,,,et, �: ��Y F� +. ({ �.� n'�4a". .. �.• i,..-:3� �; '�Y9'_. >a.;x,..-,`df,��,e. -' ::d. 3 , .> �" :� Z• ! ,! T €I: � � :k'• w, � t E Y i M F 1 �f x £ • � x to x ;. ;. ">«�' �, ^'x � ,,'l :\ � -�:„>Y;N �«,� ,,, .. �4. .......�s,y .,: - Ng. is -.,.., ,.a.' �:". 4:�`_,.a ,_�•;;. e tv; '�*reyx-.: � $ � � .ems^ k? .. �:[l. 3•" ::. )d xt,..,- ,:'9.. . .."J Ste ,. ',,,,^"w.>} 7 'i w^,ry ��._ ,� 'f' a i:. NO, .,"W v� r " yy � ./. ... s..w...� .:.. .... 'tie •.-; .:n. .ai +.... a. _». I .._.,:NY�d :.a... <. ..: :� �, x .R.:> {.. �^� ..y g { ,„43. :.y,,, fi' ,. --.,?5�... ,`;�., .•r 'c�..r,-r- .�. ,=r>.:, .. .�:., r '.. r..;:: ^.. ,�, rs.. };t:. pr'3a, H�•::.:.. ',f3C.,"€ E:��S... > 'z.' �: yr,>' >s` ,r�- !., k��k'.'Ya;.: 7✓++x'z-6� :':� ... � :e i� � k <i 4 a� 'e, �.. ,y_ �,: •.., '".^:.,' txh. ,. ....« .w.;kg ,_. �.r ' ,�:r s: Y �` .,..... T:«- «.z'. ''ti, "A •��'.. ..�} .i:� ,�;. z `:.��X >� w s: ,. -+> y�kx. � ,'k'> a o--� ,/"� e �,;�i 1rw a '! €atu•:: ,; ,:: .,. � .. t. G a..'z�e.`ta���'O�„{' :.:". .*.. �.,. - a< �.`.�'<z t>: f SK;;k f _•f:�:r � `E a.'.: .. t a. .., '. .,` ..`:�` ,,!,°Pre!.tiy.. a •--,.. -„:rN. d :, «;"�.. C ;zX�J'. y '.11,:f' (".`\is .t,. `S.,�. 'q'" '., � ,,,.„gym, .,.... ..,.. ,.�.,8�.. } N��� u t. , s< ,.:7.'%i { � S."�'"g� _�: i+ ka _,•.:�z.. , ...,.: -t�,-..�nb'. .r .s ..:.. .... ........¢ v .,•,,, -a.. ..-. ;.. ,.a,. >_�:.� ..�:.,. .s .s... � �,r x. -cy.. -;'9^'aar M 4^� *u. ,. .. .�fr.... exx"x�.>. •...".,, .<::, ..z�:._ �.,_,� .. -€,a.;..' `w<. .,�,... ..3 r 3 K{rvr.,- ,,M ",�9. .. ,. ...:...,E9 .=r._.a ...� ,:,. ., ,, .,.:.. »:. ,a ;k+. �:xn�.., >�. 5vr n•..: +r o,.+� is -�:&{:x. ,.;. � �>,. ,,, ;�>�.� � as d "• r� � �' �",� <�,�:, i .� ;�� �', '}'._th ....`�. , ...,,., i � :rik :. ! 4:sg7.�` s .r+< .. '.;', 1# 4 ix§ R,�q K,'. t�� ,•'�+c w�,. '0 4 _tV � 3.�i Y '�. ,* .: —•1 �4 �'f'. r!: } ,ao r `�<, :� ,:s �.i� 4 � �Na� r{.': i � S ,. :" 4 f o t arty C • kaw 35 n �P a� �:< • t'Y'"�Iwr t t �: f D� W�1 hTt3 is ",i a •Ht ,•r 1 �02/06/2001 10:24 FAX 4058402608 PZR 1 10001/006 The Planning & Zoning resource C®rporafl®n 25 South Oklahoma,Avenue, Suite 300 • Oklahoma i Oklahoma 1 City, 0 a oma 73 04 Telephone (405) 840-4344 s Fax (405) 840-2608 ®� Toll Free (800) 344-2944 &Toll Free Fax 888 523-9008 �0 To: fi• C'101h Compar>iY: MA r ��. FAX: (�� - b � ®ate: �/ �, 2001 Page's - (Including this Cover) : Subject: 14awL Message. `� l lov,+- - - -) Doke 4o va-in Qghg. IL&L UW4cznvw o i a •�_ -g ,i - _ 1' o"W' -.7 Please contact us if there are any questions or comments. Signed: Bukola Komi Extension: 617 CC: File The Staff of the Planning and Zoning Resource Corporation can be reached by email. (first name%r first name, last name initial)@pzr.com— (No Capitlization) NATIONAL PLANNING & ZONING CONSULTING SERVICE i 02;06/2(101 10:24 FAX 405840260.8 PZR 10002/006 _ r,N R ��% The Planning & Zoning Resource Corporation� 25 S. Oklahoma Avenue, Suite 300 Oklahoma City, OK 13104 ,O® Telephone (405) 840-43" Fax(405) 840-2608 Toll Free (300) 344-2544 To. N r. Ralph Jones Fax: 503-790-6230 Date: February 6, 2001 Subject: Zoning Verification Letter for; 594 Bearses !L /U-Haul Hyannis We have been engaged to prepare a Zoning and'Site Summary report for the above-axentioned site. Please consider this a formal request for a letter outlining the Zoning Designation and a Brief Description of the property, as follows: What is the current zwAn -of theDroperty? Is the property in any special,restrictive or overlay district? What are the abutting zoning designations? Was this a Planned Unit Development? If so, can we please get a copy of the PUD? Was this propem granted any"variances, special exceptions,or conditional use permits or zoning relief of any kind? If so, can we please get a copy of them? If these are not available,would you briefly outline the conditions of the applicable document? Are there any legal nonconforming issues? Was this site developed with Site Plan Ant val? If so,can we obtain a copy of it and/or a cony of the Approval Letter? To the best of your knowledge,do your records show any unresolved Zonin or r Building Code Violations and/ cam faints? Is this site in compliance with the current Zoning Ordinance Code? Please provide as touch information as possible iu' riling. Because we are workingon n a very strict timeline.we further request a faxed copy of the letter prior to its being mailed. Our client has asked that rye gather this information, as quickly as possible, so any help would be greatly appreciated. Thank you in advance for your time and consideration on the above matter. If you have any questions or concerns,please do not hesitate to telephone at the toll free number above, extension 617. Sincerely: Bukola Kongi NATIONAL PLANNING & ZONING CONSULTING SERVICE 02%06.2001 10:25 FAX 40584(12608 PZR lin003i006 LEGAL. 1) LE ! ALL THAT CERTAIN PARCEL OF LAND 1417 1 THE BUILDINGS THEREON SI-PJATED AT 594 BEARSE'S WAY. i !iJ THE TOWN OF BARNSTABLE ( HYANNISI, COUNTY OF BARNSTABLE, STATE OF MASSACHUSETTS, i ANO ;S MORE PARTICULARLY DESCRIBED IN EXHIBIT A ; Ii BEING THE LAND DESCRIBED IN DEED BOpK 72175 PAGE 11 GRANTED TO U—HAUL REAL ESTATE { COMPANY, A NEVADA CORPORATION, i BEING LOT #6, AS SHOWN ON LAND COURT SUBDIVISION PLAN # 27107,D DRAWN 5Y ARROW Ei�CINEERING, INC., SURVEYORS DATED FEBRUARY 28, 1984, AND FILED IN THE LAND REGISTRATION OFFICE AT , 80STON. A COPY OF WHICH IS FILED IN THE BARNSTABLE COUNTY OF REGISTRY OF DEEDS IN LAND REGISTRATION BOOK 768. PAGE 103, WITH CERTIFICATE OF TITLE #94303. EXCEPTING AND EXCLUDING FROM THE A8f)VE, THE FEE IN 2EAR5E'S 'WA'f ADJACENT THERETO, THE ABOVE DESCRIBED PARCEL OF LAND. IS MORE P.APTICULARLY DESCRIBED AS FOLLJ-A'S: SEC!NNING AT .A POINT AT THE NORTHWESTERLY CORNER OF LAND BELONGING TO DAM REALTY !:O AMC) THE SOUTHWESTERLY CORNER OF TWE HEREIN DESCRIBED PROPERTY; THEKiCE BY PEARSE'S WAY, A CtjP.VE TO THE LEFT SY A RADIUS OF 640.62'. AND A LENGTH OF 153.73 FEET; THENCE CONTINUING BY SEARSE'$ WA'•' N 39' 21* 55' W A DISTANCE OF 267.52 FEr- THENCE CONTINUING BY 6EARSE'S `NAY N 33' 51' 50" VV A DISTANCE OF 217,515 FEET; THENCE BY LAND OF MARK '_EVY AND MAX BRENNER S 89' 30' 47" E A DISTANCE OF 43Q,3'7 FEET THENCE BY LAND OF MATTHEW H. CAVALLINI S 52' 23' 24" E A DISTANCE OF `111,94 FEET- THENCE CONTINUING BY SAID CAVALLINI LAND S 59' 52' 33" E A. DISTANCE OF 136,V9 FEET; THENCE BY LAND OF JOHN P.-WE6B AND OTHERS S 07' 33' 16" E A DISTANCE OF 290. 3 FEET; THENCE BY LAND OF DJM REALTY CO..S 71' 06' 55" W A DISTANCE OF 58.90 FEET: { 'HENCE CONTINUING BY SAID DJM REALTY CO. LAND S 56' 09' 20" W A DISTANCE OF 249-06 FEET; V THENCE CONTINUING BY SAID DJM REALTY CO. LAND S 72' 17' 53" W A 01-tTANCE OF 70.16 FEET TO THE POINT OF BEGINNING. i�. SAID PARCEL CONTAINING 5.031 ACRES THIS DESCRIPTION DESCRIBES ALL THAT PROPERTY DESCRIBED IN THE TITLE COMMITMENT IDENTIFIED AS FIDELITY NATIONAL TITLE INSURANCE COMPANY OF NEW YGRK, COMMITMENT FILE"NO. 00-0175MA. DATED JUNE 21. 2000, �" I f _ 02/06/2001 10:25 FAX 4058402608 PZR CJ004/006 The Planning & Zoning Resource Corporation 25 South Okla[-i®ma Avenue, Suite 300 * Oklahoma City, Oklehorna 73104 Telephone (800) 344--2944 • Fax (888) 523-9008 Name: , 0 Title: Jurisdiction* ®ate: C2 Address: Zip: � - Phone: ( � FAX: To Whom it May Concern; I am the official named above and 1 represent the jurisdiction named above in the capacity also listed above. Please be advised that for the property located at: img5e,5 There are no current or planned condemnation proceedings (such as might be required for widening of the street) which might affect the above-named site. Also please be advised that completion of this form is not contractual, nor does it infringe upon the jurisdiction's right of eminent domain at this time or in the future. (Signature) (®ate) IO2/06i2001 10:26 FAX 4058402608 PZR 005/006 gode, /o The Planning & Zoning Resource Corpgrati®n 25 S. Oklahoma Avenue, Suite 300 Oklahoma City, OK 73104 ®® Telephone (405) 840-43" Fax(405) 8+40-2608 Toll Free (800) 344-294 To: Ralph Jones Date: February 6,2001 Subject: Certificate of Occupancy for: 594 Bearses Way, [I-Haul Hyannis We have been engaged to prepare a zoning report with regard to the above site. As part of this report,it is our standard practice to include copies of the current Certificates of Occupancy that have been issued for the property. Please consider this a formal request for copies of the same. We farther request that you please take a moment to answer the following questions so that we may accurately determine the status of occupancy on site. How are Certificates of Occupancy issued for the City? (Tor instance,are Certificates issued for the building shells, for each tenant or for both? Are Certificates issued any time a use,tenant improvement or owner is changed?) If a Certificate is not on file,could you please indicate,in writing, whether one is required to be on file and/or briefly explain why the document would not be available(ie.,records are only kept for a certain period of time,Certificates are issued to oumers only,etc.) Please incorporate as much information as possible on your letterhead. Because we are working within a strict time frame,we ask that you fax the information to us as soon as possible prior to its being mailed. If you have any questions or concerns,please do not hesitate to give me a call at the toll free number above,extension 617. We appreciate your letting us know as quickly as possible if this request cannot be filled. 'Thank you in advance for your time and consideration in this inatter. Sincerely: Bukola Kongi I NATIONAL PLANNING & ZONING CONSULTING SERVICE 02/106/2001 10:26 FAX 4058402608 PZR 160o6%006 � r~ (Please copy onto your letterhead) Planning and Zoning Resource Corporation Attn: ?5 South Oklahoma Avenue; Suite 300 To Whom:t May Concern: Based on our records [choose one]: _—A valid final certificate of occupancy bas been issued and is now outstanding for the Project. (See Attached Copy Issued) Certificates of Occupancy for projects constructed prior to the year_are no longer on file with this office. The Project was constructed in . The absence of a certificate of occupancy for the Pro ject will not give rise to any enforcement action affecting the Project. A certificate of occupancy for the Project vizll only be required to the extent of any construction activity(such as either restoring,renovating or expanding the Project or any part thereot). We are unable to locate a certificate of occupancy for the Project from our records. We have evidence in.our records,however, that one was issued and has been subsequently lost or misplaced. The absence of a certificate of occupancy for the project will not give rise to any enforcement action affecting the Project. A certificate of occupancy for the Project will only by required to the extent of any construction activity either restoring,renovating or expanding the Project or any part thereof. Please call the undersigned at _ if you have any continents or questions. SiTicerely, By: Printed Narne: Title: (Title of Government Official) Assessors map and lot number'..... L�:.... .......... OF THE To ' ` 7 Sewage. Permit; number ............ .. . . ... "`... d +► e t •_ s NST OB�BBLE, House' number .. / / MAM . . .. . ! .... 39- D O,• r MAY TOWN OF BARNSTA•BLE BUILDING :IN SPECTOR APPLICATION FOR PERMIT TO ... GO.........�� /.S` �r :.. !..`� !: �lliclr �toe'l - TYPE OF CONSTRUCTION ....l�.l..........,.. .................:............. ..............................:. TO, THE INSPECTOR OF BUILDINGS: The, undersigned hereby applies.for a permit according to the following. information: ' Location ........................d0�'qf SC S ................. ..... ......... Proposed Use ..... e JAL.! ....... a��.s.:............... .................................... .. .. :... Zoning District ...' ..................................................:...........:.Fire District .../V ................................. isf.<<........ Name of Owner � . �a.!:�...... ..... ......................Address ..1. ,....`D1!;T.n w . ...E:.��}.....:.......� Name of Builder Address .....'...:. :......................... .................................... Name of Architect v04'M C ! t t�cdolrtel- :Address 9 .. '? ?f�..s .....W !.1..1M&n...mit$5. Number of Rooms .:....................:......................:....................Foundation ..., AvtCF2e . .. • ...........:...................................... Exierior .....L,.o.'1:l.C:k.91.14......13.hock...::.........:........... Roofing ..... 2e ... .�0...... ��fiv ............................ Floors .......Co.YL4;F&t e..... ....Interior ..............` ...................................... Heating ...... 05....................................................................Plumbing .................. ...... �Oo�a Fireplace ............:....................................."w::.:.......:..................Approximate Cost ...........e................................................:...... Definitive Plan Approved by Planning Board} ___________ _________19_______• Area .... J .: Diagram of Lot and Building with Dimensions Fee ....... SUBJECT TO APPROVAL•OF.BOARD OF HEALTH C T OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the:above construction. Name . ......... ................................ t - Construction Supervisor's License fJ ../,...,... 4 U-HAUL OF R. I. I No ..26587... Permit for ...ADDITION............... C�.'�!IERCIAL BUILDI . }Y ............................ Location .. 594 BearsQ.S.may.......................... ...........r... y5�Tll11tS. .......... Owner R.... .................. Type 6f Construction. ....Frame.......... ..... f- 6holt .. Lot .: ........• r/, ........ ,? , June 14 84 y '' Permit"Gra ted Date of I spectior%'.:. ......... 19 Date Completed ...................... .,�2.. f'•19Je i . Y LaP}, -14 S {� 1•- �{ � �� rya -. ^J� '... - to ` From:Brigit King To:Robin Giangregorio Date:10/_/00 Time:3:33:34 PM: Page 2 of 2 o4( 0-1 THE PLANNING be ZONING RESOURCE CORPORATION 25 SOUTH OKLAHOMA AVENUE, SUITE 400 CKLAHOMA CITY, OKLAHOMA 73 104 TELEPHONE (405)840-4344 • FAx(405) 840-21508 TOLL FREE (800) 344-2944 To: "Town of Barnstable Attn: Robin Giangregorio Fax: 508.790.6230 Date: October S,2000 SubJect: Zoning Verification Letter for: U Haul-594 Bearses I7'ay I am checking the status on the zoning letter requested back on September 13th. Please let me know, as soon as you can, when I will be able to get the letter. If we can at leash get what the zone is,in writing,that would be great! Please call. Thank you for your time and consideration on the above matter. If you have any questions or concerns,please do not hesitate to give me a call at the toll free number above,extension 619. Sincerely: Brigit King i NATIONAL PLANNING & ZONING CONSULTING SERVICE 10/10/00 Attn.:Brigit King Re: 594 Bearses Way(U Haul) I am faxing you a copy of the zoning map depicting the subject property(see `X'). B is the business zone. A small comer of the subject lot appears to be located in the RC-1 zone which is a residential district. I have been on vacation,so please excuse the delay(or redundancy if someone else answered in my absence). fl73l'nr - "i �, :' •.z..: .�» r,,. €T e., °ar- `. x .e a .:roe , .a•'' - .,s-s. ,�^*. ...n., � .: a,:.. d ::.: :: s. ;. w.e,: «": .+«w*-m".x k:.:� ,,�,. .;`ewS<a�-�. ,.�', \� ,x _x: >,,z >z ,,..w'ra .e..::. :�E: a:,. ... + €\ ✓w :,, ` `, 30. ,.,(,< t ,.,, n 2 .>>.. >: ::-azh c:� , ...y ... �:., .t)���`,, ._ ..,,. �t,x; :..,,:. "�,,:,. s--.�•,:a >& a¢. »: \ .::q. ..:,c �,� .,`D s�^ fi.>,. �'ri4< <�;• ,u. .,b ,3 v`f2: .,�,z E,. ,r e>i., �`\ �,...� .>';� :c :.4.: ,tk. .=.'•t`c,€,�'a'�'i z�. �c� .,\\..- Sa. MPN ,<��� � .,' ,` � y �»`y� -:<'� .'r.,' ,� ,' 3��^a-•aJ�, ':, ;'� �``� .;w< , F s'.� E< 7 �, - ���, �".t, xy3 ?�-�a`�,�`.a'.:�u: � 271 ,292,310 Uri& \ _..: .: .,.._ .n,..,, ,;:,.a :,. �,>- .� ».,.:. •,:� � s,..,.. i... .>.�n>r, :_;sk i Wit. '^c�- .�s :a"fit � sx;,. ,a ,. .., v� :� �« tea,, :: .. � :�..�` �• < ��. A� �.,�, �,;< >» , . ,�:- ,..�.. � �� �i ,.. ,b.� t-. . a ., .:,.::� _.._ a. z.:s*.r -x: ....,:.,. ., , ru. ... ,:.s.�.:, i >4.-,:za;§ ,F .�.. �, a'--��,: SY•- �� y ��fi'.;,� '�E. <. <v� .1u. ;a„`L t ,x.. .. ..<.. >;'aA'"..:> _.. ,.., ,.... :., .< »..., .. .,,. ,. ....; -.,..,..<rn4Y`, •5' .^F.:. F � � Y� q�„„ ,.4x <. . .,..;: d' _x ,, x ,,<.. „ .. <x ,F,n � . ;,a € .�` ..a..� '� �aa.Et•#, ! ua<' sad �: ,u t 1 4:?'.4 '�» '.z•-�. F{-_< ai dS€ P 'r�Y''p` C to°. '.a..... t < ,: � ._•, :>.... if . . <., ,,:?� ,.. .. <.._, t ._„ �t. L .,, ., .,,,.. ,.. r ..z_i .tt:.,r ,..3� ..:<x P. ,: ,�' :. .. .:•, �,4. .:_ ... t'rc :x ..�.. . s. ....<....... ", _.._ ,.,, �, -.,..:T �.,-, .aq_ _-'�.,. �, lair 'ems`E -,.. .. �.� _, _,E# _. '.: ..<.... 'fix,.,. ..» ,, ..,... ,. -E.. ,_. ....^ ,•�'� ,..x: . ... ..-. .> -.. ,:<. '�:�.. �,}, �. �'c-_, �v. .. .<x:..�-< :�..4 .a, r ..r. rx�"._g�a>.._ a .. ::: ;..,.< -,, a�.:a< ,,\ -.... „ ,.,, _. �' ,?d ! •..�'., �.�a,.§nMa.; »�gg � T t� m ... .... R",..,.,. .� _. {'' 3r. .... - ... ._. ........ r ........: ..... .. .... n. .. ....: ... .. „s'. ._ _<x.� .:xn E,Gt ...k. i€EGt ..+; "�..<.. ... 3...a- ., .� ..e.i ... �„ ... F z...•., ..u: e -x ..,<x, : ,_x .F ,i.> tS�.., E Ny. xt ��� - a Ht,t: �., ,t< .• t. E ":tl .�€ `aa a a Fcx`� xm » , C$ �..a ... t�€�.. €ceS �� ::,... �.., •�...<.,.::' ,. d :, �,. ,. .>:, v t`� Y, --.wr: -`.a ' �,4 ��R��- l�" -�' .� ^a� », .,::., .,4. � ."r,.`a,�' ."ST '.;v ,tt- .,>.} Q.,,=,: -„ .. •.: ... .,- -.°a , ..:< ',:. ", ..x #_ :a'�'tr �.0 z .� C< ,:y:. •Lru �.a:: .. ., Y3-� :::, <3-._: ,�, � , ...: yam, `<-... .... '+a �,< -::�: Ufa Z :�".'., ,EE ��<r� a. n<, r . - ti e. .,�....,, :,, �:, ."..3 ., ,z ;� .i ,,:_ is w...,, ._ <,., ,..- .,,•;,- �. `a., '�. , ,.x. � ., as �».,_-._>. {�... _- ✓ ... ... :E x W,.. s_.,,. ,,.. .,,r t ., r,� a � i.. rFr >3i,. �:.,. 17--� •�,.. �e�,- `,t YS- �. ,. , ,._,,.., ,Tu..Y,.y. ,.,, ,. ., „ .... ., x-, �,., �a.. <..--4 c.3{ aa< t✓,y, ,`L:.,, �g ,u„y ,t��,,, 3, i �s.� ,. � ,• ,:.'. ,. , ,., :� .., �f -,x' .:..ray..», J."z 4 � �'� s.> ¢ f M I JT- J,,k `e v' . .®e .. .0^. of r_m- �. ,:l",�� 3'• $. � -},&.: 3gi=i.3'._� �I' 'Hf e€ .�,e' z�_E8 T ._� £ ,i„��^` ��� Y �E ,�C �/� �t i''f �A ':� e,'fM`:,., s::�:. •,, �,..; �xy } -{.¢{$ �'_<F � ��< �`g``` �EIE�� y,�q :..? :.` , g� � .D 't E d I? 'a 'aa ♦sir •SIL � �� ���F€ # ( x'q' ^;ri �,3 � `�,» �� � � 4 x..:� r� _:i�rn a: ..: _�k�._•, :..ie,. W1J}7 H{'E c 5 u+ p, fit:p 1 \ � \ I — ` �`� �� ,.�.��= YtJr <;:� € s�' -a •»: � ,'-�a .: o�tME r Town of Barnstable x x Regulatory Services B► MASS.�. x Thomas F.Geiler,Director 9�A MASS. g' rFor,,o.,A Building Division Ralph_ Crossen,Building Commissioner 367 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 Attn. Bridgit @405-840-2608 Please find a copy of the CO and the Site Plan approval letter as requested. There are no complaints pending currently. Historic records indicate only very minor infractions. We find the manager to be most cooperative and all issues tend to be rectified immediately. At this time, there are no unresolved violations pending. I hope this satisfies your request. ZBA issues are addressed by Planning. The ZBA clerk(Sheila) can be reached at 508-862-4785. I forwarded a copy of your request to the Planning Department on 9/14. Please call me if you require additional information. P The Town of Barnstable Department of Health Safety and Environmental Services 'b S 1 Building Division n A�� 367 Main Street,Hyannis MA 02601 Office: 508-862-4038 Ralph Crossen Fax: 508-790-6230 Building Commissioner May 14, 1998 Bob Bolton U-Haul Company 738 North Broadway East Providence, R.I. 02914 Re: SPR-033-98 U-Haul, 594 Bearses Way, Hyannis (293/046) Proposal:. Install self storage units. Regrade and upgrade drainage of existing facility. Revised plan dwed 517198. Dear Mr. Bolton, The above referenced proposal was reviewed at the Site Plan Review Staff Meeting of May 14, 1998 and approved under Section 4-7.4 (2) of the Barnstable Zoning Ordinance with the following conditions: • Resolution of location of hydrant. • Trees to be planted along Bearses Way. • Connection to town sewer when it becomes available. Enclosed is you signed plan. A letter has been sent to the Cape Cod Commission which states that this does not trigger a Development of Regional Impact(DRI) referral. Please be informed that a building permit is necessary prior to any construction. Upon completion of all work, the letter of certification required by Section 4-7.8 (7) of the Town of Barnstable Zoning Ordinances must be submitted. Also, all signage must be discussed with Gloria Urenas of this Division. Should you have any questions, please feel free to call. Respectfully, Ralph Crossen Building Commissioner x � 'TOWN ' ..$ARNSTALE` CERTIFICATE OF OCCUPANC STORAGE ROOMSal _ I- PARCEL ID 293 046 GEOBASE ID #20549 - - ADDRESS 594 BEARSE'S WAY PHONE_ w HYANNIS -- ZIP _ v LOT 6 LC271 BLOCK SIZE - . DBA DEVELOPMENT' # DI STRICT HY PERMIT 47965 DESCRIPTION.-_- - - PERMIT TYPE BC00 TITLE CERTIFICATE Q8 OCPANCY CONTRACTORS: De "Atfinent of Health Safet ARCHITECTS: P - , anc .Environmental Services TOTAL FEES: BOND $_00 r CONSTRUCTION COSTS $_00 s - Zia . 756 - CERTIFICATE OF OCCUPANCY VATB P. E _ �l•L. a BLIILDI IV _ ��� = DATE ISSUED 08/10/2000 ;_BXPIRr!AT ©N THIS PERMIT CONVEYS NO RIGHT TO OCCUPY ANY STREET,ALLEY OR SIDEWALK OR ANY PART THEREOF, EITHER TEMPORARILY OR PERMANENTLY.EN- CROACHMENTS ON PUBLIC PROPERTY,NOT SPECIFICALLY PERMITTED UNDER THE BUILDING CODE,MUST BE APPROVED BY THE JURISDICTION.STREET OR ALLEY GRADES AS WELL AS DEPTH AND LOCATION OF PUBLIC SEWERS MAYBE OBTAINED FROM-THE-DEPARTMENT OF PUBLIC WORKS.THE ISSUANCE OF THIS PERMIT DOES NOT RELEASE THE APPLICANT FROM THE CONDITIONS OF ANY APPLICABLE:SUBDIVISION RESTRICTIONS. MINIMUM OF FOUR CALL INSPECTIONS REQUIRED FOR ALL CONSTRUCTION WORK: APPROVED PLANS MUST BE,AETAINED ON JOB AND WHERE APPLICABLE, SEPARATE 1.FOUNDATIONS OR FOOTINGS THIS CARD KEPT POSTED UNTIL FINAL,INSPECTION PERMITS ARE REQUIRED FOR 2. PRIOR TO COVERING STRUCTURAL MEMBERS HAS BEEN MADE.WHERE A-CERTIFICATE OF_OCCU ELECTRICAL,PLUMBING AND MECH- (READYTO LATH). PANCY IS REQUIRED'SUCH-BUILDING SHALL NOT-BE ANICAL INSTALLATIONS. 3.INSULATION. OCCUPIED UNTIL FINAL INSPECTION HAS BEEN MADE: - 4.FINAL INSPECTION BEFORE OCCUPANCY. - y' �"' -�'" "•<�'=-'" POSTTHIS , . s SO IT IS VISIBLE FROUSTREET BUILDING INSPECTION APPROVALS PLUMBING INSPECTION APPROVALS" "' ELECTRICAL INSPECTION APPROVALS Al r­ 2 2 ----- __ 3 1 HEATING INSPECTION APPROVALS ENGINEERING DEPARTMENT 2 -- BOARD OF HEALTH v • OTHER: SITE PLAN REVIEW APPROVAL. WORK SHALL NOT PROCEED UNTIL PERMIT WILL BECOME NULL AND VOID.IF CON-. INSPECTIONS INDICATED ON THIS THE INSPECTOR HAS APPROVED THE STRUCTION WORK IS NOT'STARTED:WITHIN SIX CARD CAN BE ARRANGED FOR BY VARIOUS STAGES OF CONSTRUC- MONTHS OF DATE THE.PERMIT IS ISSUED AS TELEPHONE OR WRITTEN NOTIFICA- , - � TION. NOTED ABOVE. TION. TRANSMISSION VERIFICATION REPORT i TIME: 09/19/2000 13: 16 NAME: FA>-" 919028624926 TEL I DATE,TIME 09/19 13:15 FAX NO./NAME 914056402608 DURATION 00.01:'27 PAGE(S) 03 RESULT OK � MODE STANDARD � ECM June A, 1981 A.M. FISH ODOR COMPLAINT Jerry Flemming Johnson's Auto Body May have -to send his help home. Can't stand smell I did ride out in area and observe a very strong "odor" in -the vicinity of the Fish Plant on Bearses Way L SEAFOOD PRODUCTS, INC. COPY 594 BEARSE'S WAY HYANNIS, MASSAGHUSETTS 02601 TELEPHONE-.¢17-771-3483 June 25 , 1981 Town of Barnstable Board of Health Town Hall Office Hyannis MA 02601 Gentlemen : Please' be advised that on June 25 , 1981 , we have been accused of.,fish odor eminating from our plant . ' And I assume that you are recording all complaints . , Therefore I. wish to go on record that there are no odors coming from our plant . And on " a,bove date the odor coming from the sewer beds was so bad that' it actually saturated the interior of our plant . We ceased work because of odor complaints from our employees . Some had to walk off in the middle of the morning and the rest quit at 3 :00 p .m . Sincerely yours , SEAFOOD PRODUCTS , INC . George A. Colley President - GAC : a.f I MASS. FIRE PROTECTION INSPECrQ REPORT SYSTEMS, INC. INSPECTIQ� (fNTRACT No. _ P.O. BOX 1138 No. U CONFERIIED WITH 12—B Thornton Drive BUREAU FILE OLL ' NO. •+ r -— SET 1.OF 2 REPORT TO �tIuL ' ^�r�� 1U BUILDING OR LOCATION � lE STREET :. %EI (� CITY 8 STATE r ZIP 01 INSPECTOR \ {.`�La,t(tJ `� `J 1 L' ATT. }�yP„�1Jl�j IRS gyp'`. + N U_P,Sjf�E Lo - DATE 4 .11 1. GENERAL _._ Yes N.A.# No. A. Is the building occupied accorJng to Information rutnlshed by owner or owner's repro- sanlallve? b. Is occupancy same is previous Inspection according to Information furnished by owner or Owner's representatve? c. Are all systems In service? d. Ate all lire protection systems some as last Inspection according to Information furnished by owner or owner's representative? -..r----1he. Is building completely sprinklered? 77k 1. Are all new additions and building changes properly protected according to Information fur- nished by owner or owner's representative? g. Is all stock or storage properly oerow aprtnKier piping? j- h. Was properly free of fires since last Inspection according to Information furnished by owner or owner's representative?(Explain any lire on separate sheet)' I. In areas protected by wel system,does the building appear to be properly healed In all _ yeas,Including blind attics,perimeter areas and are all exterior openings protected against entrance of cold air? 2. CONTROL VALVES(See Section 16) a. Are all sprinkler system main control valves open? t •���• b. Are all other valves In proper position? t c. Are all control valves In good condition sealed 0 supervised?❑ •••••1 •�4�• 3. WATER SUPPLIES(See Section 17) •�v+�r a. Was s wafer flow test made and results satisfactory? 4. TANKS, PUMPS, FIRE DEPT.-CONNECTIONS ,.. A:•fire pumps.;!avlly tanks,reservoirs and pressure tanks In good condillon and prop- erly maintained? i b. Ate fire dept.connections In satisfactory condition,couplings free,caps In place and check valves light? 5. WET SYSTEMS(See Section 13) a. Are cold-weather valves open or closed as necessary? b. Have anll-Ireeze systems been tested and left In sallefaotory condillon? _ c. Are alarm valves,w star-I low Indicators and tot ards In satisfactory condition? „ 6. DRY SYSTEMS(See Section 14) s. Is dry valve In service and In good condition? ` b. Is air pressure and priming water level normal? c. Is air compressor In good condition? d. Wet*low points drained during fall and winter Inspection? a. Ara quick-opening devices In'servlce? I. Have dry valves been trip tested[satisfactorily as required? g. Are dry valves edequately,protecled from freezing? h. Are valve house and heater condition satisfactory? i 7. SPECIAL SYSTEMS(See Section 18) �t A. Wars valves teslad as required? _ - b. Were all has[responsive systems tested and results satisfactory? c. Were supervisory features listed and results salisfaclory? 8.. ALARMS A. Are water motor and gong test salisfaclory? b. Is electric alarm teal satisfactory? MCI— C. Is supervisory alarm service lost satisfactory? 9. SPRINKLERS — PIPING •����i •s���t a. Are all sprinklers In good condition,not obstructed,and free of corrosion or loading? b. Are all sprinklers leas than 50 years old? 1 •1 C. Are extra sprinklers readily available? i �t •��• d. Is condition of piping,drain valves,check valves,hangers,pressure pages,open sprinklers, •����r strainers satisfactory? X 000004 e. Have sprinklers been checked for proper temperature rating? N�/ I. Are Portable the extinguishers In good condition? Nandi •tea• g. Is hand hose on sprinkler systems satisfactory? _ DUPLICATE TO: STREET CITY 8 STATE _ ZIP A TT. PECTION REPORT REPORT OF INSPECTION INSPECTION CONTRACT 1_a NO. U-j BUREAU FILE ;! NO. 1 SET OF tr Dry System Piping last checked for stoppage. j ate Dry System Piping last checked for proper pitch. 1 pate Dry Pipe Valve last trip tested._ r ts'et Systems: No? Make and Model? Dry Systems: No? Make and Modcl? �'' ,: a w\ g� 6,4-ni Special Systems: No? Type \` $ Make ind %lodcl? Condition? CONTROL VALVES Open I Secured Gosed Signs I 16. I No? T%-pe? I Yes I No I Yes I No ties I No Yes I No I Condition City Connection Control Valve Tank Control Valves Pump Control Valves �... Sectional Control Vahes 1 Ststcm Control \•aloes Yam' ►� h 1'. 1 WATER FLOW TEST \\'ate- Pressure.'_ 1 CITY A I psi TANK Psi FIRE PUMP__,/PSI \\suer Flaw Test? A (If none made. Why?) t Size I Pressure I Flow Pressure Size Pressure Flow ( Pressure rest Pipe Lucatea Test Pi+e Before Pressure After Test Pipe Located Test Pipe Before Pressure After ftniw Nam ;M 7 18. Heat Responsive Devices: Type? Type of test? Valve No A_p_C_D_�_F_ Valve No A B_C_D_E_F_ Valve No A_B_C_D_E_F_ Valve No A a C_D_E_F_ Valve No A_B_C_D_E_F_ Valve No A B_C_D_�_F_ `salve tilt :\_B_C_D_E_F_ Valve No A B C_D G_F_ \u.xtliary equipment: Nu? Type' Location? Test Results? 19. [. planation of any "Nu" answers t — gcA 20. Rccert changes to building occupancy or fire protection equipment 11. \1!ustments ;r corrections maje r, 22 Dev:raule Improvements MAE Q HYANNIS FIRE DEPARTMENT AND RESCUE � F'V C7 �_,�� 95 HIGH SCHOOL ROAD EXT. of P N1 `; 1 . HYANNIS, MA 02601 � 27 APR R i� Ralph Crossen / Building Commissioner BARNSTABLE TOWN HALL 367 Main Street HYANNIS MA 02601 FIRE NEVER TAKES r A DAY OFF r 1 1! � rt? ail 1r11� ?I�i#I! i # ? '1 I ;;� i�l ; � � _� �. j r, �� ti �� i � _ - � ,` _ -- -y _�--__ J� i -- V I _�^ I THE TOWN OF BARNSTABLE �OF TO Q O� ^ OFFICE OF i BARNSTABLE, i 9 MA51L BOAR® OF HEALTH i639 367 MAIN STREET - HYANNIS, MASS. 02601 June 261 1981 Mr. George A. Colley, Jr. Seafood Products,- Inc. 594 Bear`se' s Way Hyannis; MA. NOTICE TO APPEAR AT BOARD .OF. HEALTH HEAR.ING .FOR .HEALTH AND HEALTH. NUISANCE VIOLATIONS AT YOUR FISH PROCESSING PLANT, SEAFOOD PRODUCTS , INC. You are directed to appear at a hearing before the Board of Health at 4:45 P.M. , July 7, 1981, in the Board of Health office, 367 Main Street, Hyannis, to show cause as to why .your fish processing permit should not be revoked. Your fish processing plant was re-inspected by John Jacobi, Health In- spector for the Town of Barnstable, on June 261 1981, because of vio- lations of State regulations Relative to Fish and Fish Products noted on previous inspections conducted on June 3, 4, 16,1981. You were given twenty-four (24) hours to correct all violations. The below listed violations were not corrected: REGULATION 400.7 (B) (2) : Open plastic trays of gurry in trailer backed up to loading dock. REGULATION 400. 7 (B) (10) : Trays, scaling machines, cutting boards and utensils not sanitized. VIOLATIONS OF APPEALS BOARD CONDITIONS: Dumping of fish remains- at the Town-owned sanitary landfill. (All gurry shall be frozen and processed according to Board. of Appeal ' s conditions. ) REGULATION 40b.7 (B) 7 and 8 :. No hot water in employee' s toilet or on processing .floor. Hot water,.shall be provided and maintained by the owner. ) Violations not previously noted were: REGULATION 400.7 (6) : Heavy infestation of flies in plant. Loading dock and doors open continually - screening not provided. REGULATION 400.2 : Pallets by fence in rear area breeding flies. Also have strong odor. Mr. George A. Colley, Jr. Seafood Products, Inc. Page 2 . - June 26, 1981 You are directed to correct these violations within five (5 ) days of receipt of this order. PER ORDER OF THE BOARD OF HEALTH fin M/ el yy t r f Pub/l c Health irec o o u i JMK/mm cc: ' Board of Selectmen Mr. William Higson , Pure Food and Drug, State Dept. of Public Health Board of Appeals Mr. Joseph DaLuz l_ .t June is, 1981 Mr. George A. Colley,.Jr. Seafood Products, Inc. 594 Bearses Way � Hyannis, M 02601 Dear Mr. Colley; w On Wednesday, June_ .17th, I inspected the gishtplant on a "'strong fish odor" complaint; . I._noticed one of your einployees 'sweeping fish water over the loading platform onto the parking lot and observed.fish entrails, on the ground plus a stopped up drain in'.the parking lot. t R i [Mien your appeal #Z97,9-59 was-presented to the Board of Appeals on September 27, 1979 your Counsel, Attorney Philip Boudreat; stated: "The proposed use would not promote noxious or offensive odors...,". One of the main concerns of this operation was the question of fish odor. Based upon these concerns I shall continue to monitor the operation and trust that I.t 11 not have to.take legal action for violation of the conditions of your Special Permit. Peace, t 1 � Joseph D. Daluz 4 ` Building Connissioner JDD/gr ' + cco. Board of Selectmen: Board of Health `. Board of Appeals `. t t i 3 } 1 { il.RN CLERK 11 A T r `110VN OF BARNSTABL]E '79 OCT -4 AH 9 11 Board of Appeals .Ha,anon....R.,.....S. .R.fly. ....Davi.d....B.f.....KaP.1.?.n.... ....... .... Deed duly recorded in the ...................................................... George A. Colley, Jr. Property Owner County Registry of Deeds in Book .............................. Sama...as....abav,e............................................................... ..Registry ........................ Page ........................, .........................................._.............. Petitioner District of the Land Court Certificate No. ........................7 ........................ Book ........................ Page ................. Appeal No. ........1979-59 October 2 79 _ .................. ........................................._..._.._ 19 FACTS and RECISION Petitioner H R.,..:...$.1;5211. .,.:..R... . .A.....KSIR.IiLn ...................... filed petition on Au uat....3.............._ 1979 G.A. Collev. Jr. requesting a variance-permit for premises at ,.....Bea,rse!s Way : _ Y ( in the village ,of Hyann.i s....... adjoining remises of see attached 1 i st) ............ g P ............. _..............._. _................... . ..__..................._...._......._................................................................................................................................._._............ for the purpose of .......5pe. i.a.] ..P.. .r..m. . ....und. r...S .G.x..i.czn....P..A...... .1. a..:..pf...... the...Dar..rl.s.iab.l.. ......... _ ..._..._. .s....zane. ....d.i.�. Locus is presently zoned in...._.RM..i„ness_................... Notice of this hearing was -given by mail, postage prepaid, to all persons deemed affected and Cape Cod News & by publishing in Barnstable Patriot newspaper published in Town of Barnstable a copy -of- which is attached to the record of these proceedings filed with Town Clerk. A public hearing by the Board of Appeals of the Town of Barnstable was held at the Town Office Building, Hyannis, Mass., at ..............7._:3.Q_.......�9X1 ( P.M. Aug.Rt .. 4.................. 1979 , upon said petition under zoning by-laws. Present at the hearing were the following members: I Richard L. Boy Frank P. Congdon Gail Ni htin ale Chairman '•�VQ CT) soon of the hearing, the Board took said petition under advisement.. A view of the �jy the Board. ./� 1979-59. No............ .._................._................ ...._.......... Page ....... ............. of .........._3.......... :;� On ............September,_27.___ ........ 19 29........... The Board of Appeals found y Atty... Phi.li.p M, Boudreau represented the petitioners who are seeking a special P permit to allow a fish processing operation at the former Hood's Milk Co. building on Bearse's. Way, Hyannis in a business zoned district. Application is made under Section P. (18) of the zoning by-laws which requires approval by the Board of Appeals for a manufacturing use in a business zone; or a special permit for a use which is non-conforming; or as an appeal under Section 8 of Chapter 40A, M.G.L. from the decision of the Building Inspector. Fish will be processed by washing, filleting, packaging,and freezing and storing. The packaged fish will then be-sent to wholesale distributors for further processing and also overseas to various countries. After its final proces' ing, .the fish is sold to schools and institutions. Mr, Boudreau displayed. the type of carton which would be used to package the fish fillets and these packages will range .in size from 11 lbs. to 5 16s. The old Hood's building now comprises approximately 23,000 sq. . ft, and office space in the building i.s now used by Cape Dairy Products, the distributor for Hood's Milk Co. products. Cape Dairy Products will be in the building for a few additional months and they now occupy only a small area, The petitioners anticipate gross sales of ten million the first year, and will initially employ about 50 people with eventual employment of 100 or more. Re-assurance was given to the petitioners by the Selectmen, the Dept. of Public Works, and the Board of Health, that the use would be permitted and it was not until the petitioners bonding counsel requested certification that the use was protected under zoning, that a problem arose. The Building Inspector who had previously agreed that this was an allowed use, changed his opinion and advised the- petitioner's that they would have to file with the Zoning Board of Appeals for a special permit. Atty. Boudreau gave a hi:story of zoning in the town and sai:d .that manufacturing uses do - exist in this same business zone which do not- have Appeals Board approval and made particular mention of the candle company which manufactures candles and is in the immediate area of the locus in question. There:.is some question as. to whether or not the use by the Hoods Milk Company constituted a non-conforming use. Therefore, the petitioner's application could be for a change of a non-conforming use, an appeal from the decision of the building inspector, or appli.-cation under Section P (18) . The peti:ti:oners would construct a small addition which would be used as an engine room and which would measure approximately 30ft, x 40ft. The proposed use would not promote noxi'ous or offensive odors since there would be no cooking or canning of fish but only the freezing and packaging of raw fish and the entrails, heads, fins, and tails will also be frozen after they have been ground up,and shipped out for processing. (cont.) I, .....J 1lN... R. Uo/ _ ._............�SS._!..:, Clerk of the Town of Barnstable, Barnstable County, Massachusetts, hereby certify that twenty-one (21) days have elapsed. since the }Board of Appeals rendered its decision in the above entitled petition and that no appeal of said decision has been filed in the office of the Town Clerk. Signed and Sealed this ... . ._ .. day of ..................6 c?...:....._._....................._ 19 Z1.. _ ......... unde the pa J and penalties of perjury.Distribution:— PropertyQ Owner ......_._..._........... ........_ .......f_ .....::...............` ...... .................:......_.._. Town Clerk Board of Appeals ^ Applicant Town of Barnstable Persons interested Building Inspector Public In€ormation By - _ _...__....._..............— ................................ Board of Appeals Chairman i BOARD OF APPEALS Appeal No. 1979-55 Page 3 of 3 The petitioners will operate this business as a copartnership .and between them have the expertise necessary for a successful operation. Mr. W. John Braden spoke in favor of the petition and is the realtor handling this property. Norman Moore and Robert Conway spoke in favor of the petition and said that the town needs this type of business which will provide employment for many people. Ernest Henderson who owns land at Bearse's Way, said that he had no objection to the petition if the statements made were correct and his land value would not be adversely affected by the petitioners use. Mr. Colley said that rigid inspection of this oper- ation would be made by a U.S.D.A. inspector who will be on the premises at all times. The fish supply to this plant will come from several locations on the Cape, from Point Judith, and possibly from Gloucester and New Bedford. No one spoke in objection to the petition and the Board took the matter under advisement. 1 The Board found that the petitioners' application was properly made under Section P. (18) of the Barnstable zoning by-laws, which permits a manufacturing use in a business zoned district by special permit granted by the Board of Appeals. The petitioners' i proposed use will not be detrimental to the neighborhood; will provide increased employment in the town, and will not derogate from the spirit and intent of the zoning by-laws. The Board voted unanimously to allow the petitioners a special permit under Section P. (18) subject to the following restrictions: 1 . There shall be no additions or alterations to the exterior 1 of the building with the exception of the 30 ft. x 40 ft. engine room as shown on the petitioners" plan. i 2. All parking relating to the peti.ti.oners' operation and use, shall be contained i'n the paved area. of the peti.tioners'. property which lies within the existing chain link fence located on the property line abutting Bearse's Way. 3. There shall be natural cedar screening to consist of live cedar trees, three feet high at the time of planting, conical in shape, and planted at four foot- intervals along the existing chain link fence bordering the petitioners' property and Bearse's Way, 4. The activity at this location is limited to. washi%ng, filleting, packaging and freezing of fish, with storage on the premises of fish In its frozen state. Any other use of the premises which does not directly relate to the previously mentioned allowed activity is prohibited. There shall be no cooking , canning, or processing of fish which shall alter its original composition. Receiving an.d shipping of fish which is necessary to the operation . of this business is allowed. !t J �FTHETO� TOWN OF BARNSTABLE OFFICE OF 2 ansMAB B.. ,$, : BOARD OF HEALTH y Mn pj GOpj�1639'�`�� 367 MAIN STREET HYANNIS, MASS. 02601 July 1, 1981- Mr. Daniel J. Fern Attorney at Law P. O. Box 518 Hyannis, MA. Dear Mr. Fern: Your letter, on behalf of your client, Mid-Cape Center, Inc. , complaining of noxious, noisome and injurious odors originating from the fish processing plant operated by Seafood Products,Inc. , 594 Bearse's Way, Hyannis, was received today. Mr. George A. Colley, Jr. , the President of Seafood Products has been notified to appear at a show-cause hearing before the Board of Health at 4:45 P.M. , July 7, 1981, for violations of State Regulations for Fish Processing Plants. If the violations are corrected, there should be little or no odor from the plant. Mr. Colley, however, has advised us by letter that no odors are coming from his plant. A copy of his letter is enclosed. A Health Inspector has been checking the areas adjacent to the fish plant for noxious odors every day for the past five working days. No noxious odors have been noted at the time of his in- spections. We will continue to make a daily check and will in- form Mr. Colley to take immediate corrective action if any noxious odors are detected originating from the fish plant. The plant also appears to be in violation of the conditions set forth by the Appeals Board in the granting of a special permit. Enclosed is a copy of a letter sent to Mr. Colley by the Building Commissioner. Please be assured. that we will give this matter our utmost at- tention. Very truly yours, - irector of Public Health JMK/mm encl. 2 cc: Selectmen John Klimm Town Counsel Appeals .Board Building Commissioner ✓ f RECEIVE SEAFOOD PRODUCTS, INC. HEALTH DFPT. S94 BEARSE'S WAY TOWN OF BW,1S V1.1_E tJ HYANNIS, MASSACHUSETTS 02601 TELEPHONE_617-771-3483 JUN= 2' 9 1981' June 25 , 1981 Town of Barnstable Board of Health Town Hall Office Hyannis MA 026.01 Gentlemen Please be ' advised that on June 25 ,- 1981 , we have been accused of -fish odor eminating from our plant . And I assume that you .are recording all complaints . Therefore I wish to go-.on record that there are no odors coming from our plant . And on above :.date the odor coming from the sewer- beds was , so bad that it actually -saturated the interior of our plant . We -ceased work because of odor complaints from, our employees . Some had to walk off in the middle of .the morning and the rest quit at 3 :00 p .m. Sincerely yours , SEAFOOD PRODUCTS , INC . _ George A Colley President - GAC . af t cl / - , r JOSLPH D. DALUS - TELEPHONE, 7715-1120 EXT. 107 Up; TOWN OF_. BARP�STABLE v T BUILDING INSPECTOR TOWN OFFICE BUILDING HYANNIS, MASS. 02601 June 18, 1981 Mr. George A_ Colley, .Jr. Seafood Products, Inc. 594 Bearses Elay . Hyannis, MA 02601 . Dear Mr. Colley: _ On Wednesday--, "June 17th,:~Z-inspected the fish plant on a 'strong fish odor" complaint._j noticed 'one :of-your. employees sweeping fish water-over the loading platform onto the parking lot and observed.fish entrails on the ground plus a stopped up drain in the parking lot. When. your appeal #1979-59 was presented to the Board'of Appeals on September 21, 1979 your Counsel, Attorney Philip-Boudreau; stated: "The proposed use would not promote noxious or offensive odors. . . . . One of the main concerns of this. operation .was the question of fish odor. Based upon these .cornceras I shall continue to monitor the operation and mist that I_will not-have to take legal..action for .violation -of the conditions of your S cial Pert. -_ pe - - - Peace, _ w­Building s ph D. DaLuz COaIIniSSioner. JDD/gr cc: Board .of Selectmen - Board of Health Board of Appeals i The Town of Barnstable . Department of Health Safety and Environmental Services .RMWSTABLL I Building Division 367 Main Street,Hyannis MA 02601 Office: 508-862-4038 Ralph Crossen Fax: 508-790-6230 Building Commissioner May 13, 1998 Armondo Carbonell Cape Cod Commission 3225 Main Street PO Box 226 Barnstable, MA 02630 Re: U-Haul, 594 Bearses Way, Hyannis (293/046) Dear Mr. Carbonell, A question has been raised by the Cape Cod Commission and the Planning Department concerning the proposed site plan at the U-Haul building at 594 Bearses Way. This proposal is a bit unique and therefore needs an explanation: • The Applicant is seeking to add outside storage units behind the existing building. • The units are the same as the units currently on location (10 are on site currently), and is a continuation of the existing use at the locus which is "storage" both indoors and out. • The location on site is completely on top of existing asphalt and will not interfere with existing needed parking spaces. • The square footage of area to be used, including associated parking, is 39,500 square feet. • The pooling of water in the northwest end of the parking lot is being addressed. New landscaping is also being proposed in the front. • Several tanks are being removed and a fire hydrant is being provided on site. Originally the Applicant had applied for an outside area in excess of 40,000 square feet. In light of your regulation (Section 3e) which addresses outdoor commercial space greater than 40,000 square feet and the fact the Applicant has reduced the scope of the project, I do not feel it is a mandatory referral any longer. Should you have any questions, please feel free to call. Respectfully, Ralph Crossen Building Commissioner TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Map 9 Parcel 6 Permit# -/7/ 7 / Health Division Date Issued 2 gka Conservation Division Fee Tax Collector Treasurer { Planning Dept. Date Definitive Plan Approved by Planning Board Historic-OKH Preservation/Hyannis Project Street Address c Village YA { \ \ 1 Owner Address y q� C-A Z Telephone �0� Permit Request--GQ► ,t P—�—� zrd L ' ,ems PI � a Square feet: 1 st floor, existing proposed 2nd floor:existing proposed Total new Estimated Project Cost Zoning District Flood Plain Groundwater Overlay Construction Type A %j Lot Size Grandfathered: ❑Yes ❑No If yes, attach supporting documentation. Dwelling Type: Single Family ❑ Two Family ❑ Multi-Family(#units) Age of Existing Structure Historic House: ❑Yes ❑No On Old King's Highway: ❑Yes ❑No Basement Type: ❑Full ❑Crawl ❑Walkout ❑Other Basement Finished Area(sq.ft.) Basement Unfinished Area(sq.ft) Number of Baths: Full:existing new Half:existing new Number of Bedrooms: existing new dotal Room Count(not including baths): existing new First Floor Room Count Beat Type and Fuel: ❑Gas ❑Oil ❑ Electric ❑Other Central Air: ❑Yes ❑No Fireplaces: Existing New Existing wood/coal stove: ❑.Yes ❑No Detached garage:0 existing ❑new size Pool:❑existing ❑new size Barn:❑existing ❑new size Attached garage:❑existing ❑new size Shed:❑existing ❑new size Other: Zoning Board of ppeals Authorization ❑ Appeal# Recorded❑ Commercial Yes ❑No If yes,site plan review# Current Use Proposed Use BUILDER INFORMATION Name _ _ _ Telephone Number Address � ��T�1� ', License# Home Improvement Contractor# Worker's Compensation# ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO 2-,Y4V,0 SIGNATURE DATE _ap ���✓a0 /'7 6J FOR OFFICIAL USE ONLY p PERMIT NO. DATE ISSUED MAP/PARCEL NO. � ADDRESS VILLAGE -- OWNER DATE OF INSPECTION: 1.. FOUNDATION FRAME INSULATION FIREPLACE ELECTRICAL: ROUGH FINAL w ' PLUMBING: ROUGH FINAL GAS: ROUGH FINAL• - FINAL BUILDING DATE CLOSED OUT +} ASSOCIATION PLAN NO. 9. J ¢r t /ji ` I S "/J T 1 1 4 1 11 I JI :11 111 1 I .11 •. 1 I ' .' i�'%////�/.F% //. •/ 1:111 1 . 11 1 .111 �. " 1 ti 1-/•1.1•It111 _ � •1.. 11 � ■ .111 :'• • • .1 .Ii / 1 1 • •11.� 111..11 _ 11 .11 .-;11� «1\' ii//i//iU//i//////i/i/i/////////////////////////// ///// ■ .11111•�1 `?1. •II IU 11 tilll•WOW •1..�11 •II 11 • I 11 :11 �I IIII 1 �l . . ' •111 ...11 1-1•. .•.a`?c ��{,-^ern r ./.,.'?w{X'<.• �'.:� ^r... 1 n 1 : 1 111 I 1 .v a. A?(ZfEl a4 v ■ ■ •I 1 IIII _1 1 •.I Illy .Iw _� / / • ••1/ .111 :'. 11 / •1• JI/1 JI J Y1111/ 111 1 11 � 1 " 11 ••.1/..ti1. •'•IIII•.+1 '✓.11 III •• 1 •�•: ...... .. .. ..... .;.: . ){. , � ..^.;.`fiy.{y';,;,,,�1,^'+'�:)ldC;� •�:'�.'�S'fi �' ),Z`2CMrrC�°ta'.'y'}k{:.. '::- a+;.t.h.X.,;.;.}.. .._. {,...1.y-' r••):iq;::a;:y�':'`::.+y::::•i^;.22:2DiR•fiRx>.c:�;�'`y:^•{,c: sY.a.:.�'::: '. i.�,'� ..k+x•�:{+c,�.;w;;.i;„Q Sc�>y:v") :u:ac�:;:yatya::+-.r�:::'^;i?i::`����}+:a,r.:,��t r.:�,;: �.^;}:.r {>a' ..o:,;.':,cw::.^.sxga.;i.;., .�dG<r::i�t:two. y?�,�;;`::!;:;::+rEv:.£;:.1�>:�:�c+Y-'�.y`¢?.'S:.< ,c:y+�i•;;.a}icu%:v:;:va}}.. • ..,,��,vv�',;ya,.,};ia:'G.4'S):,'�'{c:;:',c`�:` ;i`:•.:. �..`�''r't�:+�):�:.::..::c.::`:t: .. r, •r. �:. ai{;,+:.4•..:ra.(.: '�.:>+.:{: .:\:{it• ):(�.:,.4' .4i-:+.'6;:;<'::"ciK:o?Sa J'. ..a•. :.,cr,. •.i.v ^�:Q>).:. )4'^ Li-.cx.}. .s.,r �i>:X)x•n✓�{-:,:,A ���n..4'.'.v.,v-vLi:ZJ�yq?, :��)..; v..,„w«vJ,:� v,::Cn:),�. •:Y::C:i'.v::-`C�3}:Ci;i„�.::: +C•;X,,••.4.r:r+, X. " p )7C- :.�:,,.p(y��+ %>?t:{;`in. :'S::Lu �ii\: }:4:Oyy :!i(.;%<i:�n�. {.}., :,:•v`-'Y t:: �}Y+v:•.;::r,':..v},.:.:•:::i;:{ �Y.!u���::��::�� ::.: !-:{n+.:r��'W. ...^.'•'�y,!:t._v}:'4)yb:^$y. :+ .w.. ruf+,y�-:..:.v.y. �. :... f..+...n. �' :i:✓ry }ri}?�'�}'iti4::jy,p.+w+��}}janc. : �?`. -ivY;a.<;,,a::,...,.,•:��..vw>c:;.y.::;;�:-:.:y)i;�":.Jc){.��{,:;:�:`•':::..icy?.�t�';��):: i•2.. k�:{�:•;k:: .:. 4:}. a,., rr¢,A24� ;•)Y,,,,:.:d:{?> }�}?:r'2;.; '!^ro:i°k:.`;r?^>:I .a!<' {� r• - ' n,36. .. •' .1 11 I 1 11. 11 •.: �,ra :;��::.•:..;.:.�..M:�r.-.:.. ;i?�.:'�ii%'?f,-'S.�:X,`4,:.`::2�:��:;r'i:;;;:?:'^:i;:%�::M ':..b:S;��:^L�y��ti-0:2;.>::f�,+�....^v. :,,,o-};,,y; o .C}�:,.;:r{:.; :`.y;#,...,• �,,{c,...-�' ^'Y^.. �'�:2�:i:w i.:.',,i., ,�`. 1 1/ >.>x4;^o•• y:2k✓: u"2^+i's:• �t ): c:�>;;•}:>`y,;';,. ai``#y y '4r .-6,^'R:o-`i: •�C...;, •cd3�i 3�l{b'%��2 a.;>z�+'fi" � a.�;'c'i-',>3.:,., � k• .u}�,•,•;,y.>,; `!:�-: ..f k-. {<,'�`„ ,,;:¢:;:;;xja)r4i4^ ::'ic: .r;.?� •,�. ;'6G'. ..M•�. r.r.ax,;;ysn: �?r4':cio,{Y,{?.:at�+r;,w>,- .�- t-��.I:^• .... , ,po4' +' - ,✓Y�}a�z-):;.;y.:,-�w.,ca)�,+ay+'bc:>`Gr. +>:{,�+y��',y��,ctac�o+xa.:�c,r:::,,��^c�,',�'��'a W,�'a",,,},' /J.:B:?+.;s,'r.K:Y •.vnxyoo�;4y;;l;:x.�,{: f:�a?:,�;Gis!.,�}:,:�::c:?):!'.:,?':r.,,r..`�.4 `..c'.''.-... ,�,'.'.6c'.`. 1 1.. X. 1 • 1 - N ywompl, 10 1 11 ■ - • 11 name. location- city shone 0 ❑ I am a homeowner perfhamng atI wade mpsel£ ❑ I am a sole aivorietor and have no one warldan in aim canaclty , 0 oa tfsis 'ob. N� I am an employer p:vviding vwrkes'txaa�easanon far my emplayets,yww ng??:y ?:,._J.,. :}:{k M,}.,, ,:=::<.}?>}�:};}£ ?:?,,..:}�?,,>}> :.- ..!;.;•:::,•......,+N .;. Mn Nxnxme!.«Rcc r=:t•. .. 0}:'3k S^..r.,.!•.....:. •. ?4 .;.:::::.: :.. ............................. .:::.:.,....;}:•..;;..;:•.:.:.... :;'; .....::.:. -.......,:.::.:::::.,,•::•:::::!•::.:\...-..:54 .y,.o, ,....,oav�. ..-.......>": fit, ......,.,v'4�., }�. ,x.•r.:k:•}+:••�:{ax?•:;.}•;'.•' ::::�fi`�r?:�:`��':?::::.:;::�::�: .... ...; ..--..:::•:::.,•::.:�••.�::•::}xy!cf..... .....{.;,.,• .,{}.. .•:,.: .. atkC ?}}...., .yrx?•xt' .2t�^.2•�r•.`k':•..; ..:,...{,. ...,..::........::...:::••:.'.::�::.:•.:,............,.....:........,•.,...• , ..%a..FY•�r:a£. .. :•r .: �£'�F. .::?�.. ...k.Y..}... -:.\.;•.::{•};•:{•x;afi.;k}}}:•:i-:i:•?:r,'.:}::{ ;?:::.:::::. .. ..... .:.,. ........ ....................r......::w.•::.i:.....:-:�°#y:a�'a.,y ...:•.,,)..:.?ttt:: c.:.r;. ��,+.,to-?'. ..... ..,. ::•t°{.4`cC?"..'•'f•:3fi�4?";"" •r.:•}}'u�x•.....}.•......;..;.......:......,.-. ......:::::.v ..........r..:......... ..}....r.4,7v{k�.. ..n.... r .a.rn:.,A?'?,rr..r.:}:?.. ,A...,..1. ..........:v ::•::........ ...v .. ... .}:::•: :....: : m•::••::::.:..v.:...v::v:?.}::.. ..::.:??:ix''a�'r-A••::tvi:?iriJ•:•-v,•x•:,'•x{•:{•iw/f:4.:?v::'•:{{::•}{O}:;{•.i;}:ji::;?L�ii?`.i<"'$i::j.;. Ct)mDanV name:. ......:.,.,>:.}}:.}: ....ka;.;:.:a.,}taysi`.'{,{r�},r.:::4>....:.. .. ..N• Cfi ?.x':r.......,r,...... ... . ..... ....:,.:::.:.v:..::.,.:.v::... ...,..ty,.,•.,:r, ,�,�.........;:.a:{.:,y,;;l.•},:: ...'{4Ci{P::' •.x:::y::}}}r}:.}:.:::.f?ti•}r:}?:::.:;::a:;{:ih:?::?•>:y.»:.:::.. ..�::....... r :.,r: kx{. 4..;? yMt4t.. y: :.n?;:.... ... .). ? em• a h `$ {a :: ??Picas , :.:..:: ....,::;: ;;•::•.;•:a:•:?::;;ha:;??::}:,}}}:ck}r.}}; - 4{• 'atko : -•wa:✓t }M. �•`'£"...tb6d:.:•::.:•..:.:• :.an::•:.t• .,r.':;`:;:-,.v. :::•...::................,..x..' t243fip4'ECcT,.. .....k}o',l?n .......�3 e?k£k':'•:.>-. , }x;::•}:•,,•S,}} ...... .... ..............................r..s..................:.,... x......,... ........,. .:yam{.•},{... ::•.::. .........•:::.:�:•n•:::.� •.;.. . . o. ... ... .• :{.w:+}x` r,}:r.:ata�,{,,;�...:wfiy.{,{},s,:;�y}}:.b:S;;:;�::::::+r:�:�:;::r::�::i:�:::, ...:'....................:•.}.......rf.......,,r..a.ar�:w..:•..,{aaF}. •X,Wr 4•woatw. .. .,}t{� Rot.:�a .•y,,,: ..m;,,;�� ,..:. ...............::...... : :........... .. ....... ...� ..;.sow,{,. r.}:{.:+ct•:?�:�:as,•;�:x{{;}x:•}:•::•:;:;::.:. addreSS�'.:::.::�:,;;.:•.�:.,•::.•::}..•}:•::•�:"';;:~�:` •`•?? �•{.x,?�•4-�ai,?;":.4?::.:1.�..,..a"i-•: '�BF. Y�'K�"•r.,,••-°Sx� t{�i3�ykc.#�''`x.... �3�w"t{,�aa ;.;..:,�w:.ti•:k<r:•:%a,.{.,•::::.:.,,. ::;-:•:.:.:. . ...:„w a 2;.• rya�avc v w ,:;{}::••M1.p:?•:}:•x.•s:c;:•::?{:is i::;:. ....:.�::•.�................,,:•:{::::;{;•x{F.•:{•:kX•rw'v... ....,SAM•. :... •.� :. .�.'•. „,"t^µa�" •. ..�'",N,n"vt:.•.•!C.t}.,,-•ki`•x,v}}.Y:.t;\.}2!{.,n.�:Y,.;?K•:,:::.M!ftJ..:::::...... .. .,,. ..kr• .h ...�.!'}}•}.::... ..a•}x£h.�q-",•-',i'•'.•-'.{''- .x:v•}.4••}:V.:w..,:x{{\•}:^�:•.}`+S'x{?:}::.:�:}:•i{.i�?:.•:. ...... .. .:.::::..;...;:}x�:i:•:::�::...a•:t;;�•>;c;'}}y.....;»•3�.}'. O,•c��••••`�3t. ?t°'6`�Y'•:,_. `.'.w•'�-;•}•} ••:v:A .. .{, .::¢h"'•• d^Cf,�}x:;••.ax•:�:.•} :•. •:::}.:::..0"^2"tra ::.:::•}:w•..�.v`s?6x::• ,��.�is{: y ,4;i•:....x... ::....:.:{ 'k r:'.a.,: �.:• '•^,, .:. .. ....:... �70 .. .. �S^ . ' �?4�".x `x:•'�F 9-}. ctbtC•d 6°R?^" }?^a`:"x'•t'}vG::}}:•: }}.} ... .}:.k:::....:;.•. .......::•:-.:�...dtv" :...-.j .....: ..:.... .... ... uco}:x.. :o:C:..,tt, ..{wx�:omn: wocc�. .trrt•:. ar.}: ::a.-• c}}., ..;�+n•}}:;::•:>::;:'. ... ........ :::.::... ....... ........woa {, .. .:.., ........... ... ^^` ".".'," �kr-`�r�t-'.},,.q;M. ......... .. ., .. .{aaxc. ac.aa.Yw,4�ee}�octocarotoom. .x.{?wf { •..;•::•:;:::<:.:;: .:!,•...:.. :.v.... ,. .,.}�..a,,.. , ..'; ..�tt4R.'?•.. ..?R?�Y:t<.. r..,wtt�::'C:i:;k<a:?<.:,,au:::i;:::;:::<.>,,.: .�. :.. ,•r{?_v::.:..'w:., ....W. \1, r xai6i{. Y... i,................:{aobi+:�'+W3oc .00c rk•: '+ aw:.. �.r vt..$�Ii'C1� tit`.•:..:•30: }}}}}:•:•2:<,:<}4 insurance'%' " ❑ I am a sole psapd=w.gmeral fir,air homeowner'(ci=lr ano aced bave hued the c= ractors listed below who have the following 'woriaers msazzoa :. ..,,,..:.:....::..........::r•::,-, K,xc"'kr�.�.'•`t•• ,., .:?Sefi�. .. r.:••. ,M,} :. -:.{$4$�.: :•?:2?:a:;... ;•:Sn'�6«k�ari'oa�e::$::> �:i:::�:::�:� :;;� ::.,:• -.�.•• :.:...:•:val....v:• �:-•.....,r, }: -.•{{•. .,�,-•...:'.•: .. -. ... .:• }.:i4�• .x• <.-�:'Yr• 'N.?C}rn':?:•{::fr:ti:£:•:444.;....}rr.;xi'v':r v:w:: ..xvti...;. ,....:::..;:}?:?wgu£}... ,+�'r.,'•:: •tom• :. ,, ,.r +' .... ..{G d:., :,,,,,,',�rv.,•,�qrnt:�},�n,r;.:{%�a::�::`•}::�::�:;.';ric:}ii>:`: ..µ .... ... ... . ... .. :.>•::.•..: .. .. n.. n..........: „C ::••. p.'v�•�• . .,..; ...•:::•h::::yx}}}.vjh ., :•:{}" •. - NOW .�•.• , }Y):IX:�;:tif::G:y�:�:;: . .:::...;vi.rk,:....?:4:{rt.:{:xr.4wr�.yfi.:•:: _ addrrsr. ......:....:.:.�.. Y•.a�?o}xo3.#a• ... . . :: :..... C7L♦ ......{..'}i►YYi!to,�',-vrn�k4<>� ..v:::.�::::.:.}}:•?:is..: ......:x•:;•:.,....a:{oc:vµ;;\:;•}' .:.ti:?i;:i�:�i:•-..?::.:::'::•.;i{;w,'}kh.M1}a'•�•�}Y}xvt {tt -'Y. '' •. .r'::.•.• 0 �. „:-r.:.:... ......... .. »<:rho-;•}?>•-•.<�:;-,�: fi}•:•{:a���w�k�`rKs`'ka?tic}::a:: { k,;r23£aac3, c•:,;:�{k::x:':s; comnanv'namt�.:,,.,":}:.cc£c.Rt}vtecfi? .�i'�..}.' :• .. ... -. } .�;wr :,::.<�<:: vi:r:{•i:..':..p:.:t{{-{:{in•:•v::•',O,y�1,v.9"D-itd-0",OS ,?}....:• ..v,...,.., ..,, .. .. - ..•.. .....::..:.......i,X}n _ '';,{.yr Y•}:..,. a�i.'r:::{.;:?:%,4i'v.?tf ..:...;:::':. n•-,vviwa4. Wv..,..?.?�.. .. p ,Y,. :'frvt,:.. }..}. ... 4 £; ••'4•:'v:4i:i:. . ..:.. ..... .....'.4+00�£7,•:rvh::?•.!:•..: '' ���xi��'� :•A.•'••.�.r•'7JOW.{:..•�`�Df��. .P,Dxtivh4{,•:.'}i.Y:il�:•'}:?^'•}%. address :{,•::.:?.:?.>.:{•ir<.;:.:..,•. .: :...:.::::.. .. . ..::::.};,.:.: . '4r...},:-4;vx'x'v::?v :?,• •r. (.. •. x:N£{tie:£:`••;::•,,.:,::::-::....... ............ .,.::.:..:•.:w::v:•{{'•:ih{-W.•Y.AXv. ..}},tSC9t{.v:., ....., ...r::•vv: �'� }.:h{.,: •�[vu:ivakb'.va •.?.,7ShU.,• xy .�::.. .. �.::..:.....•. ;v:v�:{.-w{k:ky}•f.{?^.7.gnN.!i74�;':$'rt..., r w.,.::r:•:r'•..: FaUnre to secmv ancaie as req -i.a dm2u o[MGL 1.4 e l ad to the of peaaitin of a tfae op to SI,S00.00 aadlor one years'tinprisomaentasweRascivapmaiNntadoloanofaSTOPj O OB=mdat oeofSiatt.0aa day agWmtme. Iaadeislmdthata copy of this staterrum may be forwarded to do GMce ofln►eslLiatioms oltba DlAforoa�astta jai .1 do hereby caftry ursder the p6v and paaaltier of perfury&&dw iuformadm provided atom it vm Ord coned Simature _ Dale Print name Plioae it ofHdai use only do not write in this area to be completed by sty ortowa omrha dtv or tovM: _ . , petraNtaae 0 • 0Buadlu;Deparmteat QyAccustu;Board ❑&cckif immediate response is regoired ' psdeetmews oIDee Gait&Department contact person: (tsnam 9/9S PlA! EST/MA TED PROJECT COST WORK-SHEET Value LIVING SPACE square feet X $55/sq. foot= GARAGE (UNFINISHED) square feet X $25/sq. foot= PORCH square feet X$20/sq. foot= DECK square feet X$15/sq. foot= OTHER square feet X $??/sq. foot= Total Estimated Project Cost For Office Use Only lnclusionary Affordable Housing Fee Residential Fj Commercial" Property Owner's Name Project Location Project Value Permit Number **Existing Sq. Ft. **Proposed New Sq. Ft. Fee $ IAHFORM 1/3/00 (F C M,BOARQ-Ct=BUILDING ttEGULIOTION$ ce UC11QN1 S�.(PERViSOR 'Number:. .10134 JAMES r t�BOEUP tW �a TBTFI LANE _ FiYANNFS AAA 0260Y ° Admirnstratot y,� § � Au Mark Brown 0 r U-Haul Company of Rhode Island = 1� Field Maintenance Tech tk 738 NORTH BROADWAY . EAST PROVIDENCE,RI 02914 s(401)434-8471/4 "j Fax:(401)431-1250•Cell:(401)640-8864 www.uhaul.com r 3 n C The Town of Barnstable Department of Health Safety and Environmental Services » BARNSTABLE MASS Building Division 367 Main Street,Hyannis MA 02601 Office: 508-862-4038 Ralph Crossen Fax: 508-790-6230 Building Commissioner May 14, 1998 Bob Bolton U-Haul Company 738 North Broadway East Providence, R.I. 02914 Re: SPR-033-98 U-Haul, 594 Bearses Way, Hyannis (293/046) Proposal: Install self storage units. Regrade and upgrade drainage of existing facility. Revised plan dtated 517198. Dear Mr. Bolton, The above referenced proposal was reviewed at the Site Plan Review Stag'Meeting of May 14, 1998 and approved under Section 4-7.4 (2) of the Barnstable Zoning Ordinance with the following conditions: • Resolution of location of hydrant. • Trees to be planted along Bearses Way. • Connection to town sewer when it becomes available. Enclosed is you signed plan. A letter has been sent to the Cape Cod Commission which states that this does not trigger a Development of Regional Impact (DRI) referral. Please be informed that a building permit is necessary prior to any construction. Upon completion of all work, the letter of certification required by Section 4-7.8 (7) of the Town of Barnstable Zoning Ordinances must be submitted. Also, all signage must be discussed with Gloria Urenas of this Division. Should you have any questions, please feel free to call. Respectfully, Ralph Crossen Building Commissioner Assessor's map and lot number,.. .f..:. a...�.. f ......,.... 1 F THE t t Sewage Permit •number 9...1 ��'% � ......... e�Q ♦� + {� // J�• �` `0 Z B AU STO DLE, ......... .......'...House number � Ha 1 39- i �0 71 p NAY�►. TOWN OF BARNSTABLE BUILDING INSPECTOR APPLICATION FOR PERMIT TO ! -��� 7o � !.•••.'.••.•.•..•....••.•...•.••.•.••..•..r.••..•.•••.......•1•.J......• ••• •.• •......•....... ................ TYPE OF CONSTRUCTION ....�. U c!'...... .. ...5 f�P. ................................................................................... :.o.7........19 TO THE INSPECTOR OF BUILDINGS: =-The undersigned hereby applies for a permit according to the following information: a Location y - � �h S ' S W �I ................................................................................:... ........�................ �'�. ........... ProposedUse ......'..`..p t.. ................a........................................................... .......................................... Zoning District Fire District ...J.K.......�?�.'S i,sftr�. }} r Name of Owner �� Gt . ......U ..... ..............Address }�3 f^!G'� � ....•...... •.... ............ ...................... . .......................... Name of Builder .... C..........................................Address ............—. ...~.................................................................. ... ........ 'oilV) C 1 e LAC10Vr t? -..............Address ` ....� ???rJ� .• T i i 1114"�2....���SS; Name of Architect ........................................... d..... .............. ... - V / Number of Rooms ......................................:...........................Foundation ....ra...li.c.td.e.................................................. r 4 •" ` -nExierior..: pZa<�woFr `K . ..........Roofing ..... - PN.!...... .4. '?s, iy! %ic•:'?............................ ....................... Y i Floors ...... . .................... ..................................Interior .................................. ........ ...................................... Heating . ..... ....................................................... ......Plumbing ..................................................................... Fireplace ..................................................................................Approximate. Cost vC,�c'o/a ..................................................................... Definitive Plan Approved by Planning Board ____y__________________________19________. Area ....... ............... 'Diagram of Lot and,Building with Dimensions Fee ... - as ................. ....... SUBJECT TO APPROVAL OF BOARD OF HEALTH a Y< OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS mil° hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Name ................................ Construction. Supervisor's License .1re,' .9....... U-HAUL OF R. I. A=293-46 No 26587 ' Permit for. ADDITION CC)MMERCIAL BUILDING ! t J Location ......594 Beasses Wad'.... ............. ' I .......................Xaru?is........................................... - Owner ...:HAUL OF R. I. .................................................. Type of Construction .....Fri......................... ................................................................................ Plot ............... Lot ................................ Permit Granted June 14,......................19 84 Date of Inspection ...:................................19 Date Completed ......................................19 S 3 OV read � r Comrnlamt Number: . 1635 Taken by NG-� EBVFCES Date: ' 2 8 2000 ,_ ` =° Mau/barceL•, ; Referred-to: - , UJ3AL U. S�pjwj'S SUBJECT OF COMPLAINT Business/Occuvant>Name. .% U-HAUL — 7 L fi Number .5"9 Street: BF,ARSIJS WAYAll Village: . COMPLAINT#INFORMATION 1 Complainant's Name: BELL ATLANTIC - .. `-Address: 4 _ a :v Telephone•Number: 4 . y Complaint-Description. MAN LIVING IN TRAILER IN BACK OF RENTAL OFFICE,4WANTED PHONE r INSTALLED-CHECK _ 4 W_ o emu. s . Vim• _ "Actions Taken/Wesults WILL CHECK 2/9/2000 �� • . -Date Closed / Ze -lAf ,4J� p:� ��: S,• ; f y �� 10� (\ Q 'IF C �.rt�!'G> r��•}a��,i � �. ' � � s N ' Y h 1 e 1 1 . Y .�� (yk t- t 'a r 5.`A mot 'h "fit t 4,- R ;t�• .�, '_. _ :... �, �q k..,..; ...E a 1 ..tea - Y•�j� •i`,? _ �Ilk, ie q w a �[t r _v �.- R R' g+ .. ��t•' � §ram,.; �m.t-_ tn- �rlg� i t• � ,��� ��'� ,' � R� � t ask �'-• u`r•c I AF-033 --� L t.._.. __:,.p.� _�...y,. ...' ,_§.i_ _j.�. ...,_ r- 1_.r......., 4 i`�- i r.I + ��w `-i`, •-;�_ ""—��-;^— �...� .,_~ +- I t TAY I' , ' . ... .Y. I I I 1 /I :/ 7 77.ra _ .r.> �w d ! —! L I t ICI I ! , t : , . i ' • w ! 1 I I : i f ...._ � i .. c _ z ;_ i .l 3 a L t t , - t � i � f , ! I .: ! - , , A Al x i � i -.. >�......:...»t ! d�.i...t..: ....._-..�...., x�ai..:.t.+_. �:.+,..�..,v:.+r_�i.,.. .,t-.... -- ,..�.. ,w -..� .-..,....,�.r..4. _,.,..,...., y »�. ..,J.. ...i� �•/.s J�D ..L,I..�.�.�. : i I , JA tIQ;i 14 U i' oil Y'sq ! ,led i ; — ' ,- y j o is pp S ' ! v.n i L ,,( , I I 1 ) 311 f 11 I t k pry I t , 9 � -t V f r 1 .....�.o.,-- M.,.t..„_..�.....! _f..iNPPj�, ,...5'fe•w,y,Sr�r�S_ _r... .. . ._� I�� ...- __.-_.... GI.._:. _,.._,.-._ --•,._; _._.....: :,.-,....,...e.�.,,.. ...To Ff 4: ...w.. , 9 t 14 I t , 3 _! — i I 8 i r. .{ s -... { } . . ..�... - � . �...-_, I t I, ! IPAY I r , • I �,..� I I i f '!..,.:.i-..,.,,.L: ..a._,. ..�:...v.,.J.._t,n.j....,1 I...,.�,. t —� .-<.,,........I .. ..g .._,,., ,,.. .. .. .,.» ! I .,y.,�-.,,4...,... .W..,.l,avF• I I ;.:.. _ .; .,.. i 1 !. .. � t _ i �.... _ ._ t I .: 1 1.. '• _. ,_ 19 1. I it Ott I ^—T Eli aa I { �. L. } i+ 1 ._ f P ssar ; map and lot number 09 .. �� rr- l9C�Gir�s 00v�T i THE t ewage Permit number Z BARNSTABLE, i House number Sao Me 9 0� MAI a` TOWN OF BARNSTABLE BUIL NG INSPECTOR APPLICATION FOR PERMIT TO ..... ..:....... . ..... .......................................... TYPE OF CONSTRUCTION .......................... Q�t�'OY�.�� `. ..........................:...... .................................... .. ! 0........19 . TO-THE-INSPECTOR OF BUILDINGS: w The undersigned hereby applies for a permit according to the following information: Location ...............514.......... ...:'..... ..............................................................:................................................... J. Proposed Use ............�5.�.�..........1..✓'��.�s�.l:r. I. la727 Zoning District ....................... Fire District Name of Owner .. .0.CY..�0AQS:(..`�... --Xr .Address ... ...... .. �. . ... ........... Name of Builder .... �'!. �( �' ...............Address .................................................................................... Nameof Architect ..................................................................Address .................................................................................... Numberof Rooms —�..................................................................Foundation ..................................................................:........... Exierior ............... ...............................................Roofing ..............................................................,...................... Floors .........:...... :an:<°:r..�..r.�--..................................... Interior Heating ........ ......:......... .....................Plumbing ..................... .......................................................... Fireplace ................................. ............................................Approximate Cost ... > ....................................... Definitive Plan Approved by Planning Board _______________:______________19________. Area ........................................... Diagram of Lot and Building with .Dimensions Fee SUBJECT TO APPROVAL OF BOARD OF HEALTH I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Name4................. ............... __ J ' Seafood Prodoota, Inc. ^ � � . . � ` N6�]�39.-- Permit for —.Remoda.lOunM1l . �" � ' ) ..:.---..��dg...................................................... t / | ` Location —.594.Beac:seo..Way--..------' ' � � ^ � ...................Hya=is---------------.. ~ ' ' | > ^ ' � Owner —Seafuod'Irzxductm _Jnz............... ' ( ' , Type of Construction ...............Mkaoomx.y---'. � _'----.------------------'-- ^ Plot ...... Lot ----------' ,)� Permit Granted .....................�0�^—.21]P79 ' ~ ' ^ Date of Inspection ....................................lV - � ^ � . l . ""'= Completed i � ' ' ^ ~ ` PERMIT REFUSED J ^ |....................... ............... ........................ lV | ^ ---------~--- —�'-----------. .............................. ' '. ` —.--------------..----.----.. , . . ` -----------------~.—..—.---.. . . ' Approved ---------------- lA � . --------.-----------------. , � ................. ....... ................................................... ^ ' . L . At Aswsor sy map and lot number Cf., ....... �............ '� / 1-� THE 'Sewage Permit number ....... i .................:'.......: rl,'•!.`' Z BARNSTADLE, i House number ........................ y Mae& 0o i639 9� �0 MAI a` TOWN OF BARNSTABLE s 1. BUILDING INSPECTOR r �- ` � � � APPLICATIONFOR PERMIT TO ................ . .......•................................................................................................ TYPE OF CONSTRUCTION ..... .r'`/ '�'!...............................�. ......................... ............ � .' .19 . -TO--THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: Location ...............- `�...... P l�.` ;•5..�................. .................................................................................................. Proposed Use ........... 5. .....�...� !bC`:. i , -�....... . ! !► f................................................................... Zoning District ...................... .:.'..`................ Fire District .............! ?....................................................... Name of Owner, r,},Ae„'! Q....: :Address `..r� "?..... A C. ... ��/..:�....�'?"G�.......... Name of Builder ......! 1n..a. ...Ah'..`;�................Address .................................................................................... .Name of Architect ..................................................................Address .................................................................................... Numberof Rooms ..................................................................Foundation ............................................................................... Exterior ...............a .!.5`.. ................................................Roofing .................................................................................... Floors ...............!:. .�INnc' y C �.........................................Interior ..............'. ...................................................................... IS- Heating ..................................:...,.........,.................................Plumbing ....................._.............................................................. Fireplace ..................................................................................Approximate Cost ....:..... ..vo......................................... Definitive Plan Approved by Planning Board ---------------_---------------19________. Area .................................... Diagram of Lot and Building with Dimensions Fee . SUBJECT TO APPROVAL OF BOARD OF HEALTH r I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Name .................................. Seafood Productsi Inc., 23.839...... Permit for Rez=deJ..-ComW-1.... ...............Bldg....................................................... Location .....59A.Bearzes...Way.......................... .............................Hyannis................................... Owner .......Seafood...Bro dw-,ts.,...In c............. Type of Construction .........Ma-sen-r-Y......................... ................................................... Plot ............................ Lot/ ........... Permit Gralted ...........N-ov........2_1.............19 79 Date of In,1pection ....../....................i.......19 Date Completed ...../ I ..19 I.......................i......I . t PERMIT REFUSED/ ........... .................I.....................'............ 19 ... ... ......... .. ........ ........................... . ....... ..... ......1'1' ..8. .... ..........................I............... /............................... .........1 .l. .... .............................. Approved ................................................ 19 ............................................................................... ...................I........................................................... <7�2- cry, w, 71 I I .. a L:. CALIFORNIA.DEPARTMENT": .OT FOR ES TRY::,and FIRE PROTEC-TION i OFFICE O"F::.THE. :STATE ."FIRE ";MAR SIAL :RV;- - STERED. r . LP RED IST NT PRO Dt1CT > :'Pr oduc t.` Registration No COMT . .". " F-.759.01 Product_ . Marketed : Y _.P O L Y FAS'iU " I601 SEPTILVEDA";BL�TD ". '#392..` MPtNHATTAN BEACH, 'CA:.:'902"66, This product meets the mim—muin'requiremeiits"qf flame resistance established:by.:the:Califomia.: State Fire Marshat:for.pro ducts identified in Section 13115,Cali fornia"Health and Safety Code. > The scppe of.the approved use o this,prgduct:is provided in the current edition.af"the CAliIFORNIA APPR0V LIST OF F,LAME.RETARDANT CHEMICALS AND FA"BRIGS,GEARAL AND.LIMIT'ED`APPLICATIONS COVCERNS;published bythe. California.$fate dire Marshal.. : R ° Expire: 6/30/2013 DeD y State Fire�'4ja a1~ t s The WD Allen Boulevard Farmingdale.New Yank ox+1(831(631 USA Tel,s1(t331)283-89.44 Fax+i )293.8956 IL e-mail:inf0ftovm*-Com+ Organization,Inc. Page I eceived:04/03/2009 Completed:Q4/09fZ009 Letter:M rb P.b.#: Test Report#: 2-78029-0- tITested lfeut's Style:Comtex.Content:HDPE.Width: 1 SO".Finish:None.Weight: tQ ort4yd.End Use:Sun Shades/Tensiop deuthim le Membranes For: Stom Moneett" Key Test:NFPA 701-2004 TM#2 Flat 310 Poly Fab USA LLC 1601 N.Sepulveda Blvd.,#392 Tel: 1.(440).503-9056 Ext: Manhattan Beach,CA 90266 Fax: 1-(310)•626-%39 ' PC:1H TEST PERFORME6. NFPA 701 - Standard Methods of Fire Tests for Flame Propagation of Textiles and Films 2004 Edition - Test Method f2 - Flat Sheet Specimens SPECIMEN CONFIGURATION: Ixl Single Layer; [ I Multi Gayer RESULTS REPORTED: [xj Initially l A After 72 hours water leaching [ j After 3 dry cleanings i I After 100 hours accelerated weathering t I After S launderings 8 160°F r, RESULTS: , Length Afterflame Drip Burn Char Length specimen 9i (seconds) (seconds) (mmi l 0 0 -260 2 a.. 0 '' 0, 270 3 0 0 260 4 0 0 250 5 0 0 280 6 0 0 310 7 0 0 320 8 0 0 330 .. 9 0 0 340 10 0 0 330 APPROX114ATEWEIGHT OF MATERIAL (as measured by Comark): 391 q/m' FAILURE CRITERIA: For each•individual specimen Afterflame ' Drip Burn Char Length - Exceeds 2.0 seconds Exceeds 2.0 seconds Exceeds435 mm (17.1") RETEST PROVISION: Test S additional specimens if only i specimen fails. CONCLUSION: Based on the above Results and Failure Criteria, the item tested: 1XI Passes; [ I Fails; i I Requires testing of 5 additional speci:::ens CERTLFICATION: I certify that the above results were obtained after testing specimens in accordance with the procedures -and equipment specified by NFPA 701 - 2004 Edition Test Method 02 Fiat Sheet specimens. --------------- AUTHORIZED SIGNATURE THE GOVMA}11 ORGANIZATION, INC- /rb (Page I of 23 Lam. File Copy ` ' The 96-D Allen Boulevard Formingdale,NewYotk 117355626 USA Tel.+1(631-)293.8944 Fast-1(631)293-SM e-mall:into@gcwmark.com Organization,in& Page 2 eceived:0410312009 Completed:04i0912009 er:M rb P-O.#: Test Report#: 2-78029-0- clieet's I Style:Comtex.Content:HDPE.Width: 150'.Finish:None.Weight: 10 or/sq yd,End Use:Sim Shadesrrension Ideadflratio Manbtvaes Tested For Stave Nan" M Key Test:MFPA 701-2004 TM42 Flat 310 Poly Fab USA LLC 1601 N.Sepulveda Bivd..#392. Tel: 1-(440)-503-9056 Ext: Manhattan Beach,CA 90266 trax: i-(310)-426-9639 ERECOHOITIONING': { 1 1 he @ 2201F (Standard) (x; 24 hrs @ 6gWF (Alternate, Material shrinks/disterts @ 220°F) REpfRRK3 c None. CONY MUO FACTORS: naa ; 25.4 - inches B/m= = 28.35.x .835 a o2/yw ' (Page 2 of 2) e a Tht results cnntaiead in this tepnrr relate only to itmn(s)tested.7"he test mart shall not be ►produ ed,rate O 18 full.wtthont written aWoval from The Gom wk 4hgaai2gaon.hm The 96•D Allen Boulevard Farmingdale,N w York 11735--%n USA Tel.+1(631)293-6944 Fax+1(631)203-8956 e-mail.info@govmark.cam Organizadon,Inc. page I ed:0410& ompleted:041112009 utter:14 rb jP.O#: Test Report It: 2-79102.0$ Cllettt's Comex. A Superior Fire Rated Knitted HDPE Shade Fabric Designed For Large Tension Membrane Structures And ldentillkation Architectural Shade Sails. 10 or/sq.yd Tested For: Steve Morenberg Key Test: ASTM E 84(BLDG) 825 Poly Fab USA LLC 1601 M Sepulveda Blv(L.#392. Tel: 14440)-503-9056 Ext: Manhattan Beach,CA 90266 Fax: 1-(310)-626-9639 PC: ME id TEST PERFORMED: ASTV. E 64 - Standard -es: Metritd for ,S•-;rfak�:e Burning Characteristics ot suilding Materials PRODUCT CATEGORY: (xj Textile Type Product f I vinyl Type Product f ) Other than Textile Type or vinyl Type Product: ' Note: Textile or expanded vinyl wallcoverings classified try this procedure are limited to use in sprinklered areas in certain public occupancies. If textile ` or expanded vinyl wallcoierings are used in non-sprinklered areas, a room/corner fire .test is mandated. ,such as NFPA 265 for textiles and NFPA 286 for expanded vinyls. NFPA 286 test method standard Applies no: only to expanded vinyls, uuc also to all non-textile products. There(ore, it should be crsidered for all interior finish applications in nor.-sprircklered areas. SPECIMEN MOUNTING: I j Adhered: The test specimens was bonded to three 1/4" IRC (inorganic RRinforced Cement) boards (a cement asbestos substitute) to form a test specimen the face of which was 23" i l" x 2.41. (x) Unadhered: The 23" t 1" x 24' specimen was not adhered to any substrate. instead, it was laid over a 2" hexagonal wire mesh screen and 1/4" rods. RESULTS: Flame Spread Index: 25- Smoke Developed: 36 REMARKS: None. ,Page l of 2) File Copy r 71te 96-0 Alen Boulevard Farmingdale,New York TInS-5626 USA Tel.0(631)20U944 Fax+1(631)293-B956 on�EL e-mall:infoagovmark.com OrganizatioM Inc. page, ecelved:0410812009 omplefed:04117/2009 Letfer:LL rb I P.O,#: Test Report#: 2-79102-0• Client's Comtex, A Superior Fire Rated Knitted HDPE Shade Fabric Designed For Large Tension Membrane Structures And. Ldentt!222 Architeetural Shade Sails. 10 oWsgyd Tested For. Steve Morenbag Key Pest- ASTM E 84(BLDG) 835 Poly Fab USA LLC 1601 N.Sepulveda Blvd.,9392 Tel: 14440)•503.90% � Ext. Manhattan Beach,CA 90266 Fax: 1-(310)-626-9639 CONCLUSION: Baned on the above Results and odrt iassific ,!on Spstpm tie 'te t<9ted is assigned a (xl Class I or A rating I I Class Ii or B rating I i Class III of C rating 1 Unrated pATA SUMARY.: - Tir* to Ignition: . O,CB minutes ". F µ Maximum'-Flame Spread`"Distance 5:r82 feet Maximum Flame Spread, Titre 1.7 ninutes CODE CLASSIFICATION`SYSTEt4 + f Flame'+Spread index S=Ye Devel•-Dped ^ _ ---_ Class I' or A: 0 - 25 450orlesr= Class II or Bi 26 - 75 450 or less Class III or C: 76• - 200 450 or less BUILDING CODE CITATION FOR THE CLAS5IFIC'ATTON S^HEV-F " (IJ 2006 edition, NFPA 101 Life Lifery Lode, para, 1C 2 1.4 S2) 2006 edition, NFPA 5000 Bu ldin ig Constrix Lions Safety Code,+par'a. 10.3.2, ,3) 2006 edition, internationa-:Hcildin Code, Pears. So..1 " CERTIFICATION: I certify that i-the above results were obtained after testing sFecimons in acco dance with the Procedures and egv�,Ant specified by Asi,m 9 84_ ---------- AUTHORIZED SIGNATURE THE GOVMARit ORGANIZATION, INC. CT jb/ Jf`, .. 'Page.2 of.a'} APR 2 12009 - x no results contained in this report rd3tC only to items)tested.The he test reporl shall not be role,COPY - reprodmvd,except in Rill:without written appnival ftm fhe Cinrniitrk Organization.Inc. r ,. .• is' .t�- ' .i - .. e_ d,. _ . r. w r v._ ' ' o " C` A st�perir ire rated knotted superior fire rated knitted HDPE ' shade abr c.desigrred forvse An mt�M r 'MdQ. s ade€abrte t esrgned for large tension membrane strtic#ures and h e salts eco'mtne ed for StM..ores and arcl itecturat shade sails.:.. resider�t�al and.S:R commercial instai(atioi s:` Retam eMe—! for larger commercial:instalEations unsupported spans Qf z #eel or less +th uiisuppored spans.of yip.to ioo feet ��- . :- s�'�:cif?cif:�`_±>;:.� ',`::_:"`,_'_-_. :;��.:���':t `._:;_�6:_;y'�`_sEii::;?;;:` `�a>S:_:(::?:i.; :`:::;�::.�:�t::>.�:':�.:.:.;.;:.�:i:;.`_`.:'':.�t.'�: `':�,:_5.� ;`::;:��`,°:�-' `�r�.:`���:�:�': �.'`: :. • ei ht oz er ......7,:_.::....:F.::_squa re:yardoz,persquare:yard S wh�te vv: Adoamanne Bt c C . .. :::: Br size `..' Cafe loii =;s, . 4- Y -aK r_ ........... .:........ EapRuceino Clara Midrnght Green NavyPorceiacn Red* _:;.. . S Sage Sandstone Silver .•ar N vadabte.in, • - ._-�-�,._<-�;-;.�;��:;::�:::<:s2 ':':feel:avtdtti X`ioo`feet leii .h r= = ;: : .....a,er:fiotded.'rolls:: (ate:�7 : ase�x ca:t e tfaderesisiancebatallvoeuatdoorrabrics are subject toradual fading 4Jii tine.56".worsha : ademiehan others.:: terdencyto ro C :aHisedtradamrksefPokyfabUSAIIC[a Le(( A� ' W UI w.Po tYf abUSA.cum s a A i i WARE Breaking Force ...........Ilst 134 tb1 179 1 y Breaking Extension 4& $6#% •'St3g6 % 2:2%'::: 49 Tear Resistance Bursting Force dbt ;Face ;872 _ Shade Facial '� T -.,a Fagpr Colors `. UNk96 oils%. firtpartt}PF (SJ3suaF1 fgtlry'% dal 3iVR% SJY&% kJesn upF '�i/fsU t�h±j:� White NEW 9ri5i:.i 945% 15: Calk NOW Cappuccino 940.9i; $4 7°( 2t Aquamarine 92.5 .....3 :Black .,Bronze 90 4%.; 9b :: , Claret ARidnight Green 94 90: 94 8% #f;:i'. 85% .' 9$7a/o 95 535. 23 % a 25. 1'orccelairt . 94895;': ''..J5?°6 23, fletlPOtVTExANLY 953%, 954% f9ustasap , 74� S89a.. 82 4 96: 92-0% i9 :. % ....:` `'94'd;°la Sandstone. -;. a%, .' o 929?b 14: Silver.. 84 .%':' 84.8 State Gray ., 9439 : ,;: 94:3% 1reHowr: 94`.29b. 17.:: s�,,"•�"-`' r�• 4� ' „ �� y"�,'G.'°�.=ems �, it @ � �'--�., "'7• - l k .. �'7G.4#i � ��'�? ' z r. a .....:.,::.: Ai o,avair a41e from yotrr disvibutor p The above information represents the s Dlyfat)Pro Shade$ari Hardw2re and Polytab Shade Sad Edge Wooing resuits obtained fiom independent testing "'' _ ::autfroritiesand ovasaccuraiea[±heGme A = *- r ofi pnnUrrg.Polyfiab USA LLC reserves the right to aUer prpduct specifications :.. .wi[houtnotifigtion.Pot bUSALLC - n. I fe w , Pssumes no obligation orr I1abiliry for the e. suttabilityand use of its products other ;;ss than those applications intended by 1a c the manufacturer,For more information ., contact Polyfab USA. bvtw.PpljtS`dlFiis .COYt# 3/13/13 Google Maps To see all the details that are visible on the screen, use the"Print" link next to the map. Googly - , ,. 7 X A7, + 0 OF— W �4 ,zip 4 ! • s , Y Google,Map data©2013. oogle LOCATT( i POO Ons � t c t �r Vd' � ��• Tin �� Y ' I w = µ - .� t a ��; v "L"`�ycFfi y "' � F � r �' � � � � ��'�a ��t� :�sw4 g,✓5 ;�*- v ��t 'S <�;.c � t `pr �gj�'7i •' .• � ,�,�.;.�d .t.. � .7:Z��i Y.t,.ti.°`E 'f4 � N-� i 3A f3 'fir.r MI AL '� r t t ' .. ` i' a � .,�. e -�' � •i t�, ',� Yet`,&e. R �,... ' r.. ,�' �. :�,. tf t„� .,. :.- t.._ � -�. .�:F,' fi �_'.31 a3 $ .i.'1 k .,sl,,F ��:�:! � ��� t •�:.� .�. � ,'4;+ ';.: "~;•'. :� .:r: .�..,�..i,r M:r .,a ,:.'.i. ....' .:. .; a ,..... '�"� � ,�.eq ;�"' ? �i`.,:,� Yr � � w fx: .��. "`�'h�:.;. d �:�•„ :..: .. ..:..:. .y ,_.�-, .,.. .... x ..*. r ,-.: ,., .ti :.tt,.�:.'� b.s... ...,,, ... �, .h-r ':... tt��S" <.'� .p Yk� :,�+;,''u"' p, e �c� � +`� �q,%kgjrd ra:S ,,.' .. -... ;.:e ,. :,,: �`�' : k a ,� ..,. to �"^,� na. ,� a� �'^ �.� � s�, „ky�,,:�d� t why..i"•` 5� y 1 r F a�n waa.�.., _�.:: it :. ,trt4..- �.:..��_s� ,. ,I M s:=a.. .. �" x.•..'a }. � ".. �-,,�`"' ,�, ° �� :: ...9`.,• �G s:Vx� ,.^:Fx � �i. � e '�` � �� �", kBt«.' .,.' _..�.Tc'#: -L.:�:� a;� ik` �^�.Y�' ,•. .._� '�r' + '7 ,. «�._�_ .r_' a �`vo-, ELEVATION PLAN (BOTTOM) 3/8" SS or GS CABLE U.N.O. 3/8" SS or GS CABLE U.N.O. 3/8" ROO TYP 3/16" NOTE: TENSION HIP COMPRESSION CABLE USING 3/8"TURNBUCKLE OR SIMILAR. TENSION TO M REMOVE CABLE SLACK TO TAUGHT CONDITION. DO NOT DEFLECT HIP MEMBERS DUE TO ' FXCFSSIVF TENSION 9C HIP SCALE: NO COMPRESSION CABLE SCALE 20X40 DESIGN CRITERIA 1. ALL STRUCTURAL WORK SHALL CONFORM TO THE STRUCTURAL. DRAWINGS AND SPECIFICATIONS AND MEET THE REQUIREMENTS OF THE 20OX INTERNATIONAL BUILDING CODE AND THE APPLICABLE BUILDING CODE AMENDMENTS. THE ARCHITECTURAL DRAWINGS SHALL GOVERN ALL DIMENSIONS. 2. OCCUPANCY CATEGORY: I 3. ROOF LIVE LOADS: • BASIC ROOF LIVE LOAD 5 PSF 4. SNOW LOADS: • GROUND SNOW LOAD (Pg) XX PSF • FLAT ROOF SNOW LOAD (Pf) XX PSF • SNOW EXPOSURE FACTOR, Ce 1.0 • SNOW LOAD IMPORTANCE FACTOR, Is 0.80 • THERMAL FACTOR, Ct 1.2 5. WIND LOADS: • BASIC WIND SPEED (3—SECOND GUST) XXX MPH • WIND IMPORTANCE FACTOR, Iw 1.0 • WIND. EXPOSURE C. • COMPONENTS AND CLADDING PRESSURE ROOF 14.5 PSF -. 6. EARTHQUAKE-LOADS: • SEISMIC IMPORTANCE FACTOR, le' 1,0 ,$ .; • MAPPED'SPECTRAL RESPONSE ACCELERATION, Ss X.XX %g • MAPPED SPECTRAL RESPONSE ACCELERATION, S1 '' X.XX %g ' • :SITE CLASS (ASSUMED) D • SPECTRAL RESPONSE COEFFICIENT, SDs X.XX %g •$SPECTRAL RESPONSE COEFFICIENT, SDI X.XX %g t• SEISMIC DESIGN CATEGORY A • BASIC SEISMIC—FORCE—RESISTING SYSTEM ORMSW • SEISMIC RESPONSE COEFFICIENT, Cs X.XX • RESPONSE MODIFICATION FACTOR, R 2 • DESIGN BASE SHEAR, V X.XX KIP • ANALYSIS PROCEDURE USED EQUIV. LATERAL FORCE -7. SEE PLANS FOR ADDITIONAL LOADING CRITERIA , GENERAL CONDITIONS 1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS OF ALL OTHER DISCIPLINES AND SPECIFICATIONS. THE CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS, INSERT ANCHORS, HOLES, AND OTHER'ITEMS TO BE PLACED OR SET.IN THE STRUCTURAL WORK. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND REGULATIONS DURING i THE WORK. THE ENGINEER WILL NOT ADVISE ON, NOR ISSUE DIRECTION, AS TO SAFETY PRECAUTIONS AND PROGRAMS. 3; METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAU11ONS TO MAINTAIN AND INSURE THE INTEGRITY AND STABILITY OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER THE FINAL CONFIGURATION ONLY. 4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO FABRICATION OF ANY STRUCTURAL COMPONENTS. IMMEDIATELY NOTIFY THE ENGINEER AND/OR ARCHITECT OF ANY DISCREPANCIES FOUND DURING FIELD VERIFICATION. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING TO OBTAIN ENGINEER'S CLARIFICATION BEFORE COMMENCING THE WORK. 5. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ENGINEER AND/OR ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OF ANY STRUCTURAL COMPONENTS. ALL CHANGES REQUIRE THE WRITTEN APPROVAL OF THE ENGINEER AND/OR ARCHITECT. UNAUTHORIZED DEVIATIONS'ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 6.a THE CONTRACTOR SHALL SHORE OR CRIB THE STRUCTURE FOR ALL CONSTRUCTION LOADS WHICH EXCEED THE NOTED DESIGN LOADS. DO NOT APPLY ANY ERECTION OR CONSTRUCTION LOADS UNTIL STRUCTURAL FRAMING IS PROPERLY fK.`., 1 CONNECTED TOGETHER AND UNTIL Ali TEMPORARY BRACING IS IN PLACE. 7. ALL STRUCTURAL WORK,THAT IS COMPOSED OF COMPONENTS DESIGNED BY OTHERS SHALL BE IN ACCORDANCE WITH THE " MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS AND SUPERVISED BY THE MANUFACTURER'S REPRESENTATIVE(S) "' DURING THE MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND ERECTION AS REQUIRED. "' 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY THE ENGINEER. 9. ALL ASTM AND OTHER REFERENCES ARE PER THE LATEST EDITIONS OF THOSE STANDARDS, UNLESS OTHERWISE NOTED. 10. COORDINATE ALL CONSTRUCTION ACCESS AND OPERATIONS FOR ALL WORK THAT OCCURS ADJACENT TO AN EXISTING STRUCTURE AS NECESSARY TO AVOID DISRUPTION TO SAID STRUCTURE. 11. ALL STRUCTURAL CONSTRUCTION DOCUMENTS (DRAWINGS, DETAILS, CALCULATIONS, AND ALL OTHER STRUCTURAL INFORMATION) PROVIDED ARE THE PROPERTY OF U-HAUL INTERNATIONAL / AMERCO REAL ESTATE (U-HAUL) AND ARE FOR USE ON THIS PROJECT ONLY. ANY OTHER USE OF THE STRUCTURAL CONSTRUCTION DOCUMENTS IS STRICTLY PROHIBITED WITHOUT THE WRITTEN PREMISSION OF U-HAUL 12. THE SCOPE OF SERVICES CARRIED OUT BY U-HAUL DOES NOT INCLUDE A FIELD REVIEW DURING CONSTRUCTION UNLESS OTHERWISE AGREED UPON IN WRITING. THE CONSTRUCTION DOCUMENTS ARE ISSUED WITH THE UNDERSTANDING THAT THE CONTRACTOR IS SOLELY RESPONSIBILITY FOR VERIFING ALL WORK IS CARRIED OUT IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND THAT ANY DISCREPANCIES OR OMISSIONS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND ENGINEER. 13. IF DRAWINGS AND CALCULATIONS ARE PROVIDED ELECTRONICALLY; COPIES OF THE ORIGINAL CONSTRUCTION DOCUMENTS AS DESIGNED BY U-HAUL HAVE BEEN RETAINED BY U-HAUL. U-HAUL IS NOT RESPONSIBILITY FOR ANY SUBSEQUENT CHANGES TO THE REPRODUCIBLE ORIGINAL CONSTRUCTION DOCUMENTS (I.E. DOCUMENTS PROVIDED ELECTRONICALLY) WHICH ARE NOT MADE OR OTHERWISE COMMUNICATED IN WRITING BY U-HAUL SHOP DRAWINGS / DEFERRED STRUCTURAL SUBMITTALS 1. , THE CONTRACTOR SHALL SUBMIT A MINIMUM OF THREE COPIES OF THE FOLLOWING SHOP DRAWINGS (MAXIMUM SCALE 1/8: = 1'-U') TO THE ARCHITECT/ENGINEER PRIOR TO THE FABRICATION OF ANY STRUCTURAL COMPONENTS (ONE COPY TO BE RETAINED BY THE ARCHITECT AND ENGINEER). AS A MINIMUM, ALL SHOP DRAWING SUBMITTALS SHOULD INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS OF INSTALLATION AND CONNECTIONS, AND MATERIAL SPECIFICATIONS, UNLESS OTHERWISE NOTED. 2. SHOP DRAWINGS AND OTHER ITEMS SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FABRICATION. BEFORE BEING SUBMITTED FOR REVIEW, ALL SHOP DRAWINGS SHALL BE CHECKED BY THE FABRICATOR AND BEAR THE CHECKER'S INITIALS AND SHALL BE REVIEWED BY THE CONTRACTOR FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS AND HAVE AN APPROVAL STAMP PLACED ON EACH SHOP DRAWING INDICATING SUCH. ANY SHOP DRAWING NOT CHECKED OR REVIEWED BY THE FABRICATOR AND CONTRACTOR PRIOR TO BEING SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW MAY BE REJECTED AND RETURNED WITHOUT REVIEW. 3. IN NO CASE SHALL REPRODUCTION OF THE CONTRACT DRAWINGS BE USED AS SHOP DRAWINGS. 4. DESIGN AND DETAILING SHALL BE PERFORMED USING RATIONAL ENGINEERING DESIGN PRACTICES AND BE BASED ON STANDARD PRACTICES IN ACCORDANCE WITH CONSTRUCTION DOCUMENTS AND THE BUILDING CODE AND ALL APPLICABLE BUILDING CODE AMENDMENTS. 5. THE ENGINEER'S REVIEW IS TO VERIFY CONFORMANCE WITH DESIGN CONCEPT AND GENERAL COMPLIANCE WITH THE PERTINENT CONTRACT DOCUMENTS. THE ENGINEER'S REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW, CHECK, AND COORDINATE THE SHOP DRAWINGS PRIOR TO SUBMISSION. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, DIMENSIONS, ETC. 6. AS A MINIMUM, SUBMIT THE FOLLOWING ITEMS FOR REVIEW: • REINFORCING STEEL IN REINFORCED CONCRETE AND MASONRY CONSTRUCTION - INCLUDE DETAILS OF ALL BENT BARS, VERTICAL REINFORCING AND HORIZONTAL BOND BEAM REINFORCING. INCLUDE PLANS AND ELEVATIONS AS REQUIRED TO CLEARLY SHOW ALL REINFORCING. • ALL CONCRETE CONSTRUCTION - SUBMIT A CONCRETE MIX DESIGN FOR EACH CONCRETE STRENGTH. AS A MINIMUM, EACH DESIGN SHALL INCLUDE PROPORTIONS OF CEMENT, FINE AND COURSE AGGREGATES, AND WATER, GRADATION OF COMBINED AGGREGATES, AND CONCRETE COMPRESSIVE TEST RESULTS. CERTIFICATION SHALL BE FROM AN ACCEPTABLE TESTING LABORATORY. • STRUCTURAL STEEL -IF STEEL CANOPY IS NOT PROVIDED BY U-HAUL, SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED (CALCULATIONS ONLY) BY A QUALIFIED PROFESSIONAL ENGINEER. CALCULATIONS SHALL INCLUDE AS A MINIMUM, ALL LOADS, STRESSES, AND DEFLECTIONS ASSOCIATED WITH EACH MEMBER AND/OR CONNECTION. SHOP DRAWINGS / DEFERRED STRUCTURAL SUBMITTALS (con't) 7. OTHER SUBMITTALS MAY BE REQUIRED PER THE SPECIFICATIONS OR THE SEPARATE NOTES CONTAINED HEREIN. 8. TEMPORARY OR PERMANENT SYSTEMS OR FRAMING MEMBERS THAT ARE NOT SPECIFICALLY DESIGNED, DETAILED, OR SPECIFIED IN THE CONTRACT DOCUMENTS BUT ARE REQUIRED TO COMPLETE THE FINISHED STRUCTURE, SHALL BE DESIGNED AND DETAILED BY OR UNDER THE DIRECTION OF A QUALIFIED PROFESSIONAL ENGINEER. ALL REQUESTED SUBMITTALS FOR THESE SYSTEMS OR FRAMING MEMBERS SHALL BE SIGNED AND SEALED BY SAID QUALIFIED PROFESSIONAL ENGINEER. 9. ALL SIGNED AND SEALED SHOP DRAWINGS AND/OR CALCULATIONS THAT ARE REQUIRED TO BE SUBMITTED FOR REVIEW SHALL BE DONE BY OR UNDER THE DIRECTION OF A QUALIFIED PROFESSIONAL ENGINEER. 10. A QUALIFIED PROFESSIONAL ENGINEER IS A PROFESSIONAL ENGINEER WHO IS LEGALLY REGISTERED AND LICENSED TO PROVIDE ENGINEERING SERVICES IN THE JURISDICTION IN WHICH THE PROJECT IS LOCATED AND WHO IS EXPERIENCED IN PROVIDING ENGINEERING SERVICES RELATED TO THE WORK SUBMITTED. SAID ENGINEER SHALL BE CAPABLE OF PERFORMING DESIGN AND DETAILING USING RATIONAL ENGINEERING DESIGN PRACTICES BASED ON STANDARD PRACTICES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, THE BUILDING CODE, AND ALL APPLICABLE BUILDING CODE AMENDMENTS. FOUNDATION DESIGN 1. ASSUMED GEOTECHNICAL INFORMATION: • ALLOWABLE SOIL PRESSURE 1,500 PSF 2. FOOTINGS SHALL BEAR AT LEAST XX" BELOW LOWEST ADJACENT FINISHED GRADE. FOOTING DEPTHS/ELEVATIONS SHOWN ON THE DRAWINGS ARE MINIMUM AND FOR GUIDANCE ONLY; THE ACTUAL ELEVATIONS OF FOOTINGS MUST BE ESTABLISHED BY THE CONTRACTOR IN THE FIELD. 3. ALL FOOTINGS`SHALL BEAR ON UNDISTURBED, FIRM NATURAL SOIL•OR;COMPACTED FILL CAPABLE OF SUPPORTING THE DESIGN BEARING PRESSURE NOTED HEREIN. 4. ALL SOIL SURROUNDING AND BENEATH ALL FOOTINGS, SLABS, ETC. SHALL BE PROTECTED AGAINST FROST OR FREEZING DURING CONSTRUCTION. 5. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR FOUNDATION DESIGN WHEN A GEOTECHNICAL REPORT IS NOT PROVIDED TO THE ARCHITECT AND/OR ENGINEER. 6. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ONSITE SOIL CONDITIONS. 7. THE CONTRACTOR SHOULD EMPLOY A PROFESSIONAL GEOTECHNICAL ENGINEER TO INSPECT THE FOUNDATIONS AND BEARING LEVELS AND VERIFY THAT THE MATERIAL ON WHICH THE FOUNDA11ONS WILL BEAR HAS AT LEAST THE ABOVE NOTED CAPACITY AND GIVE RECOMMENDATIONS FOR SUBGRADE PREPARATION. STRICTLY FOLLOW GEOTECHNICAL ENGINEER'S RECOMMENDATIONS FOR SUBBASE AND FOOTING BEARING MATERIAL AND PREPARATION AS REQUIRED. 8. IMMEDIATELY NOTIFY THE ENGINEER AND/OR ARCHITECT IF UNSUITABLE SOIL OR SOIL CONDITIONS AT VARIANCE WITH THE GEOTECHNICAL REPORT IS DISCOVERED AT THE FOOTING ELEVATIONS SPECIFIED. 9. THE EXISTENCE OF UNDERGROUND STRUCTURES AND/OR UTILITIES IS NOT KNOWN. IT IS THE CONTRACTOR'S ' RESPONSIBILITY TO COORDINATE WITH THE OWNER OR NECESSARY AUTHORITIES THE LOCATIONS OF ALL EXISTING UNDERGROUND STRUCTURES AND/OR UTILITIES. 10. WHERE FOOTINGS ARE IN CLOSE PROXIMITY OF SEWERS, DRAINS, CONDUITS, PIPES, ETC., THE BOTTOM OF FOOTING SHALL BE SET AT OR BELOW THE INVERT ELEVATION OF THE ADJACENT ELEMENT. CAST-IN-PLACE CONCRETE 1. ALL REINFORCED CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND APPLICABLE AMENDMENTS AND THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318) OF THE AMERICAN CONCRETE INSTITUTE. 2. ALL REINFORCED CONCRETE MIX DESIGNS SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND APPLICABLE AMENDMENTS AND THE "SPECIFICATIONS FOR STRUCTURAL CONCRETE" (ACI 301) OF THE AMERICAN CONCRETE INSTITUTE. 3. ALL REINFORCING STEEL FABRICATION AND PLACEMENT SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE s` AND APPLICABLE AMENDMENTS AND THE "MANUAL OF STANDARD PRACTICE" (CRSI MSP-1) OF THE CONCRETE REINFORCING STEEL INSTITUTE AND THE "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" (ACI 301) AND "DETAILS,AND DETAILING OF CONCRETE REINFORCEMENT" (ACI 315) OF THE AMERICAN CONCRETE INSTITUTE. 4. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (144 PCF+) CONFORMING TO ASTM C94 WITH ALL CEMENT CONFORMING TO ASTM C150, TYPE I OR II. MAXIMUM AGGREGATE SIZE SHALL BE 1-1/2" FOR FOOTINGS AND 3/4" FOR WALLS AND SLABS, CONFORMING TO ASTM C33. 5. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) AT 28 DAYS, SLUMP AND MAXIMUM WATER/CEMENT RATIO REQUIREMENTS: • ALL CONCRETE 3000 PSI 2° — 4" SLUMP* W/C RATIO = .58 6. OBTAIN EACH TYPE OF CEMENT OF THE SAME BRAND FROM THE SAME MANUFACTURER'S PLANT, EACH AGGREGATE FROM ONE SOURCE, AND EACH ADMIXTURE FROM THE SAME MANUFACTURER. 7. ALL CONCRETE EXPOSED TO WEATHER SHALL HAVE ENTRAINED AIR IN ACCORDANCE WITH SECTION 1904 OF THE IBC. 8. FOR AIR ENTRAINED CONCRETE — MAXIMUM W/C RATIO = .44 9. ALL GROUT SHALL BE NONMETALLIC SHRINKAGE—RESISTANT GROUT PROVIDED BY A MANUFACTURER APPROVED IN WRITING BY THE STRUCTURAL ENGINEER AND INSTALLED AND MIXED PER THE MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS. ALL GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) AT 28 DAYS EQUAL TO 5000 PSI. 10. REINFORCEMENT. • DEFORMED BARS ASTM A615, GRADE 60 • GALVANIZED REINFORCEMENT ASTM A767, CLASS II 11. REINFORCING STEEL SHALL HAVE THE FOLLOWING MINIMUM CLEAR CONCRETE COVER UNLESS OTHERWISE NOTED: • CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3° • CONCRETE SURFACES IN CONTACT WITH SOIL OR EXPOSED TO • EARTH OR WEATHER (#6 BARS OR LARGER) 2" (#5 BARS OR SMALLER) 1-1/2- COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1-1/2° • CONCRETE SURFACES NOT IN CONTACT WITH SOIL OR EXPOSED TO WEATHER INCLUDING WALLS AND TOP AND BOTTOM OF SLABS 1 12. WELDING OF REINFORCING BARS IS PROHIBITED WITHOUT PRIOR WRITTEN APPROVAL FROM THE ENGINEER. IF WELDING OF REINFORCING IS NECESSARY, IT SHALL BE PERFORMED IN ACCORDANCE WITH AWS D1.4. REINFORCING STEEL FOR WELDED ASSEMBLIES SHALL CONFORM TO ASTM A706 SPECIFICATIONS. 13. SPLICED BARS SHALL HAVE A MINIMUM LAP OF CLASS B TENSION LAP SPLICE PER TYPICAL DETAILS. 14. GALVANIZED REINFORCING SHALL BE TREATED TO PREVENT REDUCTION OF BOND. OTHERWISE PROVIDE SPLICE LENGTHES EQUIVILANT TO EPDXY COATED REINFORCING. 15. ALL REINFORCING STEEL INDICATED AS BEING CONTINUOUS (CONT.) ON THE PLANS AND DETAILS SHALL BE LAPPED WITH A CLASS B SPLICE OR 36 x BAR DIAMETER (WHICHEVER IS GREATER) UNLESS OTHERWISE NOTED. 16. REINFORCING BARS TO EXTEND 12 BAR DIAMETERS BUT NOT LESS THAN 12" BEYOND BAR BENDS, UNLESS OTHERWISE NOTED. 17. PROVIDE ADDITIONAL BARS AS SHOWN IN TYPICAL DETAILS. 18. ALL REINFORCING STEEL SHALL BE SET AND TIED IN PLACE PRIOR TO POURING OF CONCRETE. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE ENGINEER IN WRITING. 19. PROVIDE CORROSION RESISTANT ACCESSORIES SUCH AS PLASTIC COATED (NOT PLASTIC TIPPED) OR STAINLESS STEEL CHAIRS IN ALL EXPOSED CONCRETE CONSTRUCTION. PRECAST CONCRETE CHAIRS OR SAND PLATE CHAIRS SHALL BE USED FOR THE SUPPORT OF REINFORCING ON GRADE. CONCRETE BLOCK OR CLAY MASONRY BRICK ARE NOT PERMITTED. 20. ALL EXPOSED CORNERS OF CONCRETE TO HAVE 3/4- MINIMUM CHAMFER UNLESS OTHERWISE NOTED. 21. CONCRETE SHALL BE DISCHARGED AT THE SITE WITHIN 1-1/2 HOURS AFTER WATER HAS BEEN ADDED TO THE CEMENT AND AGGREGATE, ADDITION OF WATER TO THE MIX AT THE PROJECT SITE IS STRICTLY PROHIBITED. ALL WATER MUST BE ADDED AT THE BATCH PLANT ONLY. 22. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CONCRETE OPENINGS AND/OR PENETRATIONS REQUIRED FOR OTHER TRADES PRIOR TO PLACING CONCRETE. 23. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR REGLETS, PIPE SLEEVES, CONDUITS OR OTHER ITEMS TO BE EMBEDDED OR PASSED THROUGH CONCRETE. CONCRETE/MASONRY ANCHORS 1. EXPANSION BOLTS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE KWIK BOLT TZ (ICC ESR-1917) AS MANUFACTURED BY THE HILTI CORP. OR AN APPROVED EQUIVALENT IN STRENGTH AND EMBEDMENT. 2. ADHESIVE ANCHORS SHALL BE HIT-RE 500-SD (ICC ESR-2322) INTO CONCRETE AND HIT HY 150 MAX (ESR-1967) INTO MASONRY AS MANUFACTURED BY THE HILTI CORP. OR AN APPROVED EQUIVALENT IN STRENGTH AND EMBEDMENT. 3. ALL ANCHORS SHALL BE INSTALLED WITH STEEL WASHERS. 4. WHEN USING ADHESIVE ANCHORING SYSTEMS THE MANUFACTURER SHALL SUPPLY THE ANCHOR AND ADHESIVE, UNLESS OTHERWISE NOTED. 5. ALL ALTERNATE PRODUCTS SHALL HAVE A CURRENT ICC EVALUATION REPORT. 6. ANCHORS INSTALLED INTO MASONRY UNITS SHALL BE INTO FULLY GROUTED .CELLS UNLESS OTHERWISE NOTED. IF GROUTED CELLS ARE NOT ENCOUNTERED, BREAK INTO CELL AND GROUT SOLID 8". 7. ALL ANCHORS SHALL BE APPROVED FOR USE WITH CRACKED CONCRETE AND CONFORM TO CURRENT ICC ES'REPORT (ICC-ES AC193 FOR MECHANICAL ANCHORS AND ICC-ES AC308 FOR ADHESIVE ANCHORS). 8. INSTALL ALL ANCHORS IN STRICT ACCORDANCE WITH ALL APPLICABLE ICC-ES AND BUILDING CODE REQUIREMENTS. ALL ANCHOR SPACING, EMBEDMENT, EDGE DISTANCE, AND INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. REFER-TO SECTIONS AND DETAILS ON THE DRAWINGS FOR ADDITIONAL INFORMATION. 9. ALL PERSONNEL INSTALLING MECHANICAL/ADHESIVE ANCHORS SHALL BE TRAINED BY THE PRODUCT MANUFACTURER ON PROPER INSTALLATION TECHNIQUES. TRAINING DOCUMENTATION FROM THE MANUFACTURER SHALL BE AVAILABLE UPON REQUEST. STRUCTURAL STEEL 1. ALL STRUCTURAL STEEL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND APPLICABLE AMENDMENTS AND WITH THE "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" (1989 EDITION) OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. 2. ALL STRUCTURAL STEEL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND APPLICABLE AMENDMENTS AND WITH THE 13TH EDITION OF THE "STEEL CONSTRUCTION MANUAL" OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. , e 3. GRADE OF STEEL • OTHER SHAPES, PLATE, AND BARS ASTM A36 ' • HOLLOW STRUCTURAL SHAPES (HSS) ASTM A500, GRADE B • STEEL PIPE ASTM A53 TYPE E, GR. B • GALVANIZED STRUCTURAL STEEL STRUCTURAL SHAPES AND RODS ASTM A123 BOLTS, FASTENERS AND HARDWARE ASTM A153 • 'ANCHOR RODS ASTM F1554, GR. 36 • THREADED ROD ASTM A36 4. ALL FIELD CONNECTIONS SHALL USE BOLTS, UNLESS OTHERWISE NOTED. ALL SHOP AND FIELD INSTALLED BOLTS SHALL BE 3/4" DIA ASTM A325 TYPE N BOLTS IN STANDARD HOLES, AND SNUG TIGHT, UNLESS OTHERWISE NOTED. ALL BOLTED CONNECTIONS SHALL HAVE 2 BOLTS MINIMUM, UNLESS OTHERWISE NOTED. 5. HARDENED WASHERS CONFORMING TO ASTM F436 SHALL BE USED AT A325 BOLTS AND A490 BOLTS USED IN FRICTION CONNECTION AND OVERSIZED AND SHORT SLOTTED HOLES. 5/16'THICK PLATE WASHERS OF STRUCTURAL GRADE MATERIAL SHALL BE USED AT LONG SLOTTED HOLES. WASHERS SHALL HAVE A SIZE,SUFFICIENT TO COMPLETELY COVER' THE SLOT AFTER INSTALLATION. 6. ALL MODIFICATIONS REQUIRED FOR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS, AND MADE DURING SHOP FABRICATION.' FIELD BURNING OF STRUCTURAL STEEL IS PROHIBITED. a. ` i 7. ALL WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING CODE-STEEL". WELDING FILLER METAL SHALL BE AWS A5.1 OR A5.5 E70XX LOW HYDROGEN ELECTRODES. WELDERS SHALL BE AWS CERTIFIED. SUBMIT COPY OF ALL CERTIFICATIONS TO THE ENGINEER. SURFACES TO BE WELDED SHALL BE WIRE BRUSHED CLEAN BEFORE WELDING. 8. ALL EXTERIOR METAL FABRICATIONS EXPOSED TO WEATHER SHALL BE GALVANIZED, UNLESS OTHERWISE NOTED. SPECIAL STRUCTURAL INSPECTIONS 1. THE OWNER WILL HIRE AN INSPECTION AGENCY OR RETAIN THE ENGINEER OF RECORD TO PERFORM ALL REQUIRED SPECIAL INSPECTIONS AND TEST. 2. SPECIAL STRUCTURAL INSPECTIONS SHALL BE CONDUCTED AND DOCUMENTED AS PER CHAPTER 17 OF THE IBC AND ALL APPLICABLE AMENDMENTS FOR THE FOLLOWING ITEMS OR AS REQUIRED BY THE BUILDING OFFICIAL: • STEEL CONSTRUCTION STEEL CONSTRUCTION MINIMUM SPECIAL INSPECTION: GENERAL CONFORMANCE AND BOLTS ONLY; ALL WELDING TO BE PRE-QUALIFIED SHOP WELDS WHERE POSSIBLE, PERFORMED IN A SHOP AND BY A WELDER THAT IS AWS CERTIFIED. ALL STEEL FABRICATORS THAT ARE NOT PRE-APPROVED BY THE BUILDING OFFICIAL SHALL BE INSPECTED IN ACCORDANCE WITH SECTION 1704.2 OF THE IBC. • CONCRETE CONSTRUCTION • ANCHOR BOLTS IN PRE-DRILLED HOLES IN CONCRETE OR IN MASONRY r SITE SOIL CONDITIONS (AS REQUIRED; SEE FOUNDATION DESIGN NOTES) 3. ALL SPECIAL,INSPECTIONS SHALL BE CONDUCTED BY A QUALIFIED SPECIAL INSPECTOR AS DETERMINED BY THE BUILDING OFFICIAL AND/OR PERFORMED UNDER THE SUPERVISION OF THE ENGINEER OF RECORD. 4. A STATEMENT OF, SPECIAL STRUCTURAL INSPECTION IN ACCORDANCE WITH SECTION 1705 OF THE IBC SHALL BE SUBMITTED TO THE BUILDING OFFICIAL PRIOR TO BEGINNING OF ANY SPECIAL STRUCTURAL INSPECTIONS BY THE SPECIAL INSPECTOR. 5. SPECIAL STRUCTURAL INSPECTION REPORTS SHALL BE FURNISHED TO THE BUILDING OFFICIAL AND THE ENGINEER OF RECORD IN ACCORDANCE WITH SECTION 1704 OF THE IBC. } ss.-7. - -----------------------------------------------, I I I I I I I I I "�44-2 I - j j I I I I II-------------------------------- 1 s 1 20'x40' STEEL CANOPY FOUNDATION PLAN SCALE: 1X'=r-o 40•_0• 10'-0, 20'-0' 10'-0' 81 I e - ,I I , I I q I I .'-j ` — � ,GALVANIZED,�NSS ax4x3/tfi',OR j :t I I GALVANIZED N55 4:OOOxD taa OR -. -:, APPROVED EQUAL, 'KNIITEX®COlOURSHAOE RAINFOREST OR _ ' °ROYAL DLUE''CANOPY OR EOUAC APPROVED '. BY U HAULs CONSTRUCTION DEPARTMENT a M220'x40' STEEL CANOPY PLAN SCALE: 1/40=P-0° 10'-0' S3.1 TYP 20'-0'TYP ] KNITTEI(&COLOURSHADE'RAINFOREST'OR 53.1 'ROYAL BLUE"CANOPY OR EQUAL APPROVED BY U—HAUL CONSTRUCTION DEPARTMENT. 40'-0' 5 TYP S3.1 . J-." la T1 L ;1F 3 12GAG STEEL CANOPY SIDE ELEVATION SCALE: 1/4'V-0' KNRTEXOCOLOURSHADE'RAINFOREST' OR 'ROYAL BLUE'CANOPY OR EQUAL APPROVED BY U—HAUL CONSTRUCTION DEPARTMENT. 6 53.1 TYP GALVANIZED"SS 5.000xO.25 OR 20'-0' APPROVED EQUAL,TYP. .I 5 TYP S3.1 � T.uir L_jL III — iL-1 ell I�Ir AIL. LI, `I� J11_ ll Il[ 1F �1 III =jT -1 1= t�- 1All U, IIV-H1-:1 4 201x401 STEEL CANOPY SIDE ELEVATION SCALE: 1/4"=V-0* LAP SPLICE LENGTHS (IN.) LENGTHS IN. BAR LAP 2500 PSI 3000 PSI 3500 PSI 1 4000 PSI 4500 PSI 5000 PSI _ SIZE CUSS TOP BARS 5 OTHER BARS TOP BARS 5 OTHER BARS TOP BARS 5 OTHER BARS TOP BARS 5 OTHER BARS TOP BARS 5 OTHER BARS TOP BARS5 OTHER BARS CASE 1 CASE 2 CASE i CASE 2 CASE ICASE ACASE 1CASE 2 CASE 1CASE 2 CASE ICASE 2 CASE ICASE ACASE ICASE 2 CASE 1 E CASE 10ASE 2 CASE 1CASE 2 CASE 1 13 A 24 36 18 27 22 33 17 25 20 30 16 23 19 28 15 22 18 27 14 21 17 25 13 20 B 31 46 7i 36 28 42 22 33 26 39 20 30 25 37 19 28 23 35 18 27 22 33 17 25 #4 A 32 47 24 36 29 43 22 33 27 40 21 31 25 37 19 29 24 35 18 27 23 34 17 26 B 41 61 32 47 38 56 29 43 35 52 27 40 33 49 25 37 31 46 24 35 29 44 23 34 #5 A 39 59 30 45 36 54 28 42 33 50 16 39 31 47 24 36 30 44 23 34 28 42 22 32 B 51 77 39 59 47 70 36 54 43 65 33 50 41 61 31 47 38 57 30 44 1 36 54 28 42 I6 A 47 71 36 54 43 1 65 33 50 40 60 31 46 1 37 56 29 43 1 35 53 27 41 34 50 26 39 B 61 92 47 71 56 84 43 65 52 78 40 60 49 73 37 56 46 69 35 53 44 65 34 50 #7 A 69 103 53 79 63 94 48 72 58 87 45 67 54 81 42 63 51 77 40 59 49 73 38 56 B 89 134 69 103 81 122 63 94 75 113 58 87 71 106 54 81 67 100 51 77 63 95 49 73 #8 A 78 117 60 90 72 107 55 83 66 99 51 77 62 93 48 72 59 88 45 68 56 83' 43 64 B 102 153 78 117 93 139 72 107 86 129 66 99 81 121 62 93 76 114 59 88 72 108 56 83 A 88 132 68 102 81 121 62 93 75 ll 2 58 86 70 105 54 81 66 99 51 76 63 94 48 72 B 115 172 88 132 105 157 81 121 97 146 75 112 91 136 70 105 86 128 66 99 81 122 63 94 ¢10 A 100 149 77 115 91 136 70 105 84 126 65 97 79 118 61 91 74 Ill 57 86 71 106 54 81 B 129 194 100 149 118 177 91 136 109 164 84 126 102 153 79 118 96 144 74 ll1 92 137 71 l06 #11 A 110 165 85 127 101 151 78 116 93 140 72 108 87 131 67 101 82 123 64 95 78 117 60 90 0 143 215 110 165 131 196 101 151 121 182 93 140 114 170 87 131 107 160 82 123 102 152 78 117 14 N A 133 199 102 153 121 181 93 140 112 168 86 129 105 157 81 121 99 148 76 114 94 141 72 108 18 N/A' 177 265 136 204 161 242 124 186 149 224 115 172 140 209 108 161 132 197 101 152 125 187 96 144 [EL:AP SPLICE SCHEDULE FOR UNCOATED CONCRETE REINFORCING BARS .Detail Notes: 1.,TABULATED VALUES-'ARE BASED ON GRADE 60 REINFORCING BARS AND NORMAL WEIGHT CONC. 2. TENSION LAP-SPLICE LENGTHS ARE CALCULATED PER ACI 318, SECTIONS 12.15. TABULATED VALUES FOR BEAMS OR COLUMNS ARE BASED ON TRANSVERSE REINFORCEMENT AND CONCRETE COVER MEETING MIN. CODE REQUIREMENTS. 3. CASES 1 AND 2, WHICH DEPEND ON THE TYPE OF STRUCTURAL ELEMENT, CONCRETE COVER, AND CENTER—TO—CENTER SPACING OF THE BARS ARE DEFINED AS: BEAM OR COLUMNS: CASE 1 - COVER AT LEAST 1.0 db AND CENTER-TO-CENTER SPACING AT LEAST 2.0 db CASE 2 — COVER LESS THAN 1.Odb OR CENTER-TO-CENTER SPACING LESS THAN ' 2.0 db. ALL OTHERS: CASE 1 — COVER AT LEAST 1.0 db AND CENTER—TO—CENTER SPACING AT LEAST 3.Odb. CASE 2 — COVER LESS THAN 1.0 db OR CENTER—TO—CENTER SPACING LESS THAN 3.0 db 4. ACI 318 DOES NOT ALLOW LAP SPLICES OF #14 OR #18 BARS. THE TABULATED VALUES FOR THOSE BAR SIZES ARE THE TENSION DEVELOPMENT LENGTHS. 5. TOP BARS ARE HORIZ. BARS WITH MORE THAN 12 IN. OF CONCRETE CAST BELOW THE BARS. ,6. FOR GRADE 40 REINFORCING BARS, MULTIPLY TABULATED VALUES BY 0.61 (12" LAP MIN.). FOR LIGHT WEIGHT CONC., MULTIPLY TABULATED VALUES BY 1.3. R LAP-SPLICE LENGTH FOR UNCOATED REINFORCING BARS LENGTHS (IN.) SINGLE MAT DOUBLE MAT BARSIZE 1500 PSI 1800 PSI 2000 PSI 1500 PSI 1800 PSI 2000 PSI #3 19 17 17 19 17 17 #4 1 25 23 22 31 29 27 #5 31 29 27 49 45 42 #6 53 48 46 98 90 85 #7 67 61 58 133 122 116 #8 93 85 81 186 170 161 #9 119 108 103 237 216 205 NOTES: 1. LAP-SPLICE LENGTHS ARE CALCULATED PER 2006 IBC 2107.5. 2. TABULATED VALUES ARE BASED ON GRADE 60 REINFORCING BARS. 3. FOR GRADE 40 REINFORCING BARS MULTIPLY TABULATED VALUES BY 0.67 (15" LAP MIN). 4. MECHANICAL SPLICE REQUIRED FOR BAR SIZES GREATER THAN #9. (MECHANICAL SPLICES SHALL DEVELOP 125% OF THE TENSILE STRENGTH OF THE BAR) 2 - LAP SPLICE SCHEDULE FOR MASONRY REINFORCING BARS No SCALE RECOMMENDED END HOOKS(All OEfAJUNG DIMENSION HOOK GRADES)D=FlNISHED Aar G BEND MENDED BAR 180 HOOKS 9U'HOOKS SIZES D(in.) A or G J A or G 3 2 1/4 5 3 6 D 4 3 6 4 8 5 3 3/4 7 5 10 4d,2 1/2 MIN. " +6 4 1/2 8 6 1-0 180 r 7 5 1/4 10 7 1-2 ' + 8 fi 11 8 1 1-4 ' 19 9 1-3 11 3/4 1-7 90. 10 10 1/4 1-5 1-0 3/4 1-10 71 11 1/4 1-7 1-2 3/4 2-0 �714 17 - 1 2-3 I-8 1/2 2-7 78 22 3/4 1 3-0 2-3 3/4 1 3-5 10 90' SEISMIC STIRRUP/DE HOOK DIMENSIONS(ALL GRADES) BAR 1357 HOOKS 80'HOOKS SIZES D(in.) A or G H APPROX. A Of G xo `� 136 3 1 1/2 4 1/4 3 4 x 4 2 4 1/2 3 4 1 22 5 2 1/2 5 1/2 3 3/4 6 6 41/2 8 41/2 8 '�.' x 7 5 1/4 9 5 1 4 9 - /8 6 10 1/2 6 10 ALL SPECIFIC SIZES RECOMMENDED BY CRSI BELOW MEET MINIMUM s O REQUIREMENTS OF AC1318 d z a 3 REINFORCING STANDARD HOOKS NO SCALE I,L ' REINFORCING DEVELOPMENT LENGTH OF STANDARD HOOKS TABLE-TYPICAL U.N.O. BAR CONCRETE MASONRY , SIZE ALL ALL 3 9 5 4 11 6 5 14 8 6 17 9 7 20 10 8 22 12 9 25 -- 10 28 -- 11 31 -- 14 -- -- TABLE NOTES: 1. DEVELOPMENT LENGTHS ARE CALCULATED PER ACI , 318-05, 12.2.3, EQ. (12-1) FOR CONCRETE AND ACI 530-05, 2.1.10.5.1 FOR MASONRY. •2. DEVELOPMENT LENGTH SHALL BE INCREASED BY 30% ` ,-:FOR LIGHTWEIGHT CONCRETE. SCALE: 4, REINF. D' VLPMNT STANDARD HOOKS TABLE NO SCALE TYP HSS HIP PER PLANS " Typ STEEL ROD 1/2' DIA X 1 3/4" LONG ' N COLUMN CAP. HSS 5.500xO.188 X 6" LONG W/ 3/8° X 5 1/2" DIA. _ (2) 1/2" DIA A325 BOLT W/ STEEL CAP PL, NUT WELDED TO ONE SIDE OF HIP * - ' N Y + (2) 1/2' DIA A325 THRU BOLT W/ WASHER AND NUT STEEL COLUMN PER PLANS SCALE: 6C 20'x40' STEEL CANOPY COLUMN CAP DETAIL NO y., SCALE r . CL COL'M, & CONCRETE FOUNDATION FTG BEYOND TYP TYP 1 STEEL COLUMN PER PLANS 1/2" THICK x 12° DIA. STEEL BASE PL • - I I ' I I (6) 3/4" DIA ANCHOR RODS STEEL COLUMN PER PLANS EQUALLY SPACED (16 MIN EMBED INTO FOOTING). 1/2- STEEL GUSSET PL I LITEEL BASE PL 1 1/2" NON-SHINK GROUT IHARDSCAPE OR FINISH GRADE OR 1 1/4° NON-SHINK j AS OCCURS. GROUT W/ 1/4" LEVELING PI r, N LAJ Cj II a _ fCONCRETE PIER. REINFORCE W/ m f f I (8) #5 VERT BARS EQUALLY 4 a. Q I I SPACED AND #3 TIES ® 6" O.C. VERTICALLY. PROVIDE DOUBLE TIES - ' AT TOP OF PIER. ALL TIES TO Lo ENCOMPASS VERTICAL REINF AND ANCHOR RODS AND BE TIED TO -` Qe VERTICAL REINF. TE 31-GLR. 2'-O° P ' 15C 20'x40' STEEL-CANOPY FOUNDATION DETAIL 3�1 1I-Oil " 3/8" STEEL PL. CUT TO FORM RIDGE AND HIP SLEEVE. HSS 1/2" STIFFENER PL (ONE AT 4.500x0.188 X 24" LONG RIDGE AND EACH HIP) (2) 1/2" DIA A325 BOLT 2—0" HSS RIDGE PER PLANS W/ NUT WELDED TO SLEEVE TYP HSS HIP PER PLANS 6" MAN. ---------- ----- S� e P 4 1�2 � TYP 7C 26x40' STEEL CANOPY HIP DETAIL NOSCALLE RIDGE AND HIP SLEEVE. HSS 4.5000.188 X 24" LONG _ 1/2" STIFFENER PL BEYOND (ONE ` AT RIDGE AND EACH HIP) HSS HIP PER PLANS `�� ' HSS RIDGE PER PLANS rr r 2'-0" TYP r rrr r rr TYP 8C 20'x40' STEEL CANOPY HIP/RIDGE DETAIL SCALE: 3/411 = 1'-011 . . ALTA/ACSM LAND TITLE SURVEY M1110'I'A LEGAL DCSGi11MI, CERnFiCAnON Lom rw:w F or.my.Gnaatal.araeaA rmaar,ca"r,a..mr N n..,,o.'.I(a.yy.ivre®s+crua>r�,at�p,.ae r:.ww.Nu..en rvLkwrr emew me amen m tawa: u.iuuLc«J awA.+a.ca�rru+ dem,@ to la a.w.+m Lma wn a,ePwM w:��,�m amm b rm. (>.a Wrort+.wt Fn.(••)...fwe..r�au. Jv�o "/�\ barpaa••rvr'Nxyar.NJN drtrlr.)r i6 r.Md Ma3a'�9,n Wh.at Wdw�awau%�✓r1 *j LC1QJ5 _ (. � 1 W pMpNgr yydp.r'n'lrwAtlorlr4.WJ b CaMy N.ay.N Pwa a tma X 1auegn Pn MA R•tat aa) .[� ! _ Nppo-o-dd N„i MRe aaaedva eWN•ltYawa.Ad•i GnPYNeN rW(1Nm:) f . ,3J �, Mon Arga)rwbALTAIAlbl tditm lr.aJ.;pam)vaeed ,,f� d.MDd ALr duvsrmos.dmaweaa•)t.),nor, umrr+ro w wyrero ww m..r.a a.<w'm Pom•.*ar oelcrm flF9 + �j A¢v.y)udvb l.pdyALTA dN9)da.Q,uNnurd zn _ / GXty ,�` �.SGLBrt: N�m.wo ar. .r+�rr..n+a y�vwe6•a+N + p SlI1tVIYOR`S LEG AL DESC0.11''170N PsumJ�.v�d a.wawrdur"N asWer di.6F p.Shcws m,td"w<N J ram F m.•faw.J Uerotad.(1ry�y ,F dmrte{)io.n.���a�yan, N DJnNaR rb Cmnv.+e4E d amwNu•mn LrNd W�L�:AeJ P _ � .u6m,ty NlW• •lsee wa•Ma.MdM1Nwpd �yam.p J a wM F q•aa�•f+mt�rw N bsNa 1T.W OJ't ///�VVV r'Aa^r'•�"^`tea'ww*•^a'! '^n+4•W eaao se.rQ:•aNrh torso N u. e+wm.e wow rera. b � gt Vdean.,u0wsw eP+eddmr.o ML 8 W)P'a>'[M L+m m.a rrma,J P.ewr t Aw•ue.a.eN {reins u�m) \.� _ + t - N w.y.nr .w.k-.+nw.i.re rtr>�N"..d-.rm qJF W.r M..�+1,.r.L M wa a..waL tr•aw>aa d ate.J.«t v.a Yn e.la.a w.m dew`LF yr e+r(n16a 6.11 dNted,�Nf• y.�[F�r� s W i(•Jr[Dr trk rx,r1.f d 1Ffb d II Ill ¢y a:•a.myt•I dt may m.Lea t6r(\oprry.narrNnna Msa. t.•L t+rnte.CmNan b W to exh( m+FSaxs d tI1.01.taa tx m dw ew'e. dw °�'°'0�'"`)ww�.eA>p:.,*rr[ei+V aW�srywc• � I sr r,iesoo f.N,o xa t,.Mad udw..x.<auw is. � • ! rlvrd.dlmwrm F.gaTma[W J'L' N N .. ! eu / - .. Teu[a�}awem.•r Or11A (1st6vw.PmPm re4Na.¢O )nm4p,W•l1Wd YrarLrnl[PP+•••IM M w1.q,va�AlMamC r. ' ��•+"��.��p".�.�,�� tv,r mwi n,.rr}.LbddAq�9.rNi,MtwasMn W.}So�r. AYmn d)ORa)fiw,m a tenC 4rsr . "_..,,,,�," ! -� - R,.d►wv.Fwv. w,b6 lr^r^^wx[b`4SaYM^d'�e+coral. )!n 09'JO'T b v r)atm+w d OA6«I(a Wbi wtta \ 1'' ' � \ mc. � "��r"S � ,� .xn am [ , .. ��[,.r��..w.a,a.•d mWt _ I Ce.Lrrw ma 6mb di4lFittaD nw..md.rtd �'«aar0 Nvry 9'a"'n-,aaeNV 4<F N Owa+'•err tluq a caa b If ' '"."�,.. - / ).a.n�aw a1..•1.o Tavatppd W rv..[dm.ai.ra art.&A.ra4ua Wh'reN,a ea enpn a im1.J)rµ v a QF✓t J�.,,,,,_�•"•.'`�y�f o,ryJ+U C ai Rat+.v+M.fr I(.dv.l 4�r. eawM M+t JS 20 M v!•NM Iryq N,D).H NN is a - �I.•. �Y\t I .-..(,,.�.� \ -. . b.ryl.�nr TY4Wwrt.Cr+yvNYn. yr+ab r 1 Omrn:bFm' 1IFF \\\ Ca9 b rort eY+3 ens M Mmw:etl b a s '�?a. 'ac.e,an .din.d✓.�.wN Jn,.ro-.rd...+.ms� "s)r r t i�uo bi u�Pacer �w owr.a:wr e«L " ,.�\YiL"\ . r,a.riar. / �^` •a aat .. ... ,,`T.,r r....,F,t..w -ana('�`•n cmwrwa aw.r.J).a+rat .P tr.N N enx>ra.re..m F.,. , �. _ \\ \ 3n)a)ACW.S ' ( .. •,a"S$� r••• L _ Poor ..,1y . \ `� 4 " 'n ,� .wo Prr.•.+".ea iP � � .wa.m...nnv�.c�:m..cm.was uiLm. RV 5T R 1 O SUEY RELATED rIF.MS CO" RF_SPONDINGTOSCHFI)ULER_ "—� ® \ �,a """",�,.'.P;:r•r.„.ra"""*".m..r,�.,w"..n'.ma..sp.°.'.. znr.•.r.r.mo+ar r.:xa n.,..mJ.sLnarw n swa>A 4 � S6 •� .+a'.�" .,..: 2\` ISM f \{4 FLOOD NOTE I I TP\ - . O 9 \ b� 6S �'at mr.ar �,t� mr�{` �� .a ����.:.�:-r:'.�..r"•..,r. i � a - o .+'' '•� a 0 BASIS Ol S ' �- -;,. .. �y�& '��` ) ow,«rc s�`raLx � �iwq 1} ..r+-•s ma�.rr RG ... 12I1S. � - }7 1RIh< •walV..l STATEMENTOF ENCROACIVA• 1 i.LA.N REFERE\CFS ffi � l + _ yr ffi I PARKING AND RENGIAIARK U rr. (A. AREA AR - aar2;„ « rr '796067 .,• LEc>ry UHAUL# i - ,sn.sP• ti QP'�°i" r •- t csnats(roL,rP)rtRu.ea,r �A. cSi A _x re ,ua•�u .mvuP+ars'w si i 594 Ikmes Way'Ilyannb,MA Project I - ,_ unan 1 1\ ;; ^. �•'o „ ��w FIUDSON•RICIiARD5I0INt 2007-06A015 i •. w •caca[r[ :' war �j° SURYF.YOR°S JOB t?194$SFIT I OF 1 lNa Surajpr.vnd fixnUVSI)N PS01A0.US.CiG, �-v —.mrwm e— a General Notu .. ,. c 0 N E C O nus.Aso[>rr�rerrRcnarna a[aPs c f Ring .nsMntoa(A ,tFP�" :4t tix)0(H M aui Itl.1G U5[D A;A SMr+aU'.T Qi1P, " fing)narnrs, Scienlisls noP•ca saae„nr ufwru. - it - m 4nnt!Swna J,ru[p[rA:w to>t'xlanr(wtrcPa a oPT«w.ar, cy0rs rdaa aa.ma wxv nA,irar.rat axann+s'rr�an nuo.J U D 5 U N RICHARDS w r a.,Fw Pe D l FOR ANY AND ALL INQUIRIES PLEASE CON1 ACT CONECO ENGINEERS&SCIENTISTS,INC. VIZ..cu iLm a \I�1 Tom-N- P n �R�ary IT���a�•+�s�r> I The Commonwealth of Massachusetts William Francis Galvin- Public Browse and Search Page 2 of 2 First,Middle,Last,Suffix Address,City or Town,State,Zip Code REAL PROPERTY MICHAEL F.TAYLOR 25 HARVARD STREET WEYMOUTH,MA 02188 USA Consent _ Manufacturer Confidential Data _ Does Not Require Annual Report Partnership X Resident Agent X For Profit _ Merger Allowed Select a type of filing from below to view this business entity filings: ALL FILINGS Annual Report i Annual Report-Professional xFtj Articles of Entity ConversionII3 Certificate of Amendment 2 'I m,.FtS. New Sea Comments m 2001-2013 Commonwealth of Massachusetts tad All Rights Reserved Help http://corp.sec.state.ma.us/corp/corpsearch/CorpSe'archSummary.asp?ReadFromDB=True... 3/29/2013 I • • • ��' < E.Yk'. � xy}'xA� h '� fi'' e f:ItI �,�.'•✓a .. ,. Eta .. - `'` f,y o-t �A, �.,rt4 d - (•ra+•}•i tt 'F�•1,,.,ie� - - % - ;�tf /r _,,,,'. - - • _ ✓ J/ IV y" "42"` 411 , '�- :"�,� fs�"_�,Et� •vi 4 1.( ° .T, ' a '*Siw•3:'f,:^.:lmt a,r ,3," v ... :;.. ...;;, .� :...� xi-'+:.t. h.ra�^e .,ir ^[.13. .'•.. :-E st:4: a ° '[.' •r . .': :. - .::. .':; .r. r -r •Gde , �1 l.�� 5+ ;er jq'�{�71� E :a .x..t a ?# 3 c .. 1W �, r.k 3,a.: >-✓t �'.. .. (( 1..1} 'xr�"-a,'•,:�+�!�� •a s..°.;/,... f `•.'�.,i vq - :g.. t 4'` S -!:3 +�, -,rr:: 4:•.r ..,:4.�. 1vr"i ry:¢.., a: I X 4 ` } qk' 01 lf.:'4 -it.-30 j:e:3 i s I '";;'•. a z,.,'= ` .. - � r>p- S. rFf'-..:A ✓•- LK'�-���.+ r -j.+ P � �, d, r{.� rr 1�� .. x.}�- - .'�rBy :ri..((ri:� -;=%,, /'....� �•,.. � �,/ _ ark„ p�. pit- 1 r,v,.,}ylbr�. :'vr :.. ..�.,. :. .. - :� r �;r d... }'- S n- _'r•., >. _ ,:w.. .:; bra ,,.,.�, :,..,r. <:_ ..:. �:1 _: :-.^.'=„"'. n- `• s, r,., �"`a. r g Y •.y.a-t, .. .-: .,. .i .,:+ r--_-7 _ ..!L� YX f��7jwFJl ... r�i 4. .:_-«.M' -. .:... .- � .. '�+. -L.;r -.fY.J,�:^1 k, - � : . ...,..... - � .:?i .. ... ..,.. ;. S•-•.. .. .. .,�.-.•�.r,.. ..'r• ..�,- �' <y<c. $s.a,. i. s+-c:; +t-`..;.si t �.. 'r'`-w.. zr .,-._„••r, .y,t„ ,.,.... ,..�.,.- ;,.. .-.r,:>.. f.. ..,,.... .. .- .., .z � ...-r. ---cam �.T,�. ,.-, �.l om.,. .r.,,. ,:z� .,,.ro x .^,i,r.:. , :.: .,'S.. .-. ,; ... .,..:� .... ..-^ .. .. b. -.. ^.S' .. ..t ,�... 1 •t<':k� ,k....,,tY'� ti� Y d r n a. �4 .... .:-.,:. ... .- '�. ..v :.- ..: ...._ .._ .. -.,.-�. ._ ,...- -.. 1�s,r!-. .� :,k.. ,t:. c•.x ,a" ., as t �„�r�"»a ':_t .: ,r ... _.. ..,t .... ..: .. • a.-_._ s. e _ _.. ... _.,... _.-.. _. ....--• .-- I i ... ,.. .:,x.:4' ti 1 "s.: Y x t '"5r.. .� �-_: - .r .....c... . . ::, -.. .._. -_.,... -,� .. .:�.. .-•" _ .- _... _..,:_.�,__ .._, -._. .., r- .:}t A.. i:i .a+q.. "i�� �5 +k-'- .r:a� ,ti._ ..,k., -.aa „'-<.v2,::.•.r:to- -,.-t: "k tx a... •r,..:-.; ..-r', ._� :....:... .�.. ..� __"' ='-...---• ..'x. r a:3s i. /`. •f�.� �-,.:.f 5 w. !.r lfk'. _ - _ r`.: �..sa'-: .r.... ..<...._:-. .. ......__.. ...,.:�. ,.. :,.r - rN\ •.-._....-- .._. . ,-.r-�.>y' S. !- ,.b.'.v4. p Y 1„Y-. ey'r. .:_ .... >., ., ..,.'t_ .,r .... :... ;. ._...-..._•,�..._.-: .- ...t�—•.mot.. mot. 's� t,�'Sr&}i -.<�}'ri -. �,� -� 4'!�a_=,. .,.- „. .,:,„, w._-.....:,., ..-. :.-.. .-`a r. -x-._.-- ..._.-.-. � 3 �.i•,.: fir+ 'r 3 �^' ¢...7. - -- r. ,.x Fa _ � 1 Zzz . ,,,.: - ry_,. _.. 1 ... ,.., ., ,. -.+ ,;r ...-, _.. -.- -.,.. , �_�-,.....-•r rl`'+ ��v ,.r+'%-' 1��ir ;<iP E. $ � 3. v�� '... .;. .::..,r .v-.. -;yam.--i - _. t,. ;: ..- _=-_' .. .__..i' _":.,r•-r.-•-„ i =::.t .e '• IT" sr, 'r•a.•• t+. a��+�,°..+:"�. '3^' -sc-' i r1 / , E - ''r �"- A '.. ' t :! _ __ .tea.. � ......_ .,a � 3•..� � - �' - .rE� dw z �.r '' t v r ..S�':T"'� i F.st .., ..,- s d- — �� .»�---� _"`w:� i1 .• :.: ''•�°6\ 'w �,t , * to r.,'+,X c..+-' �. V,.w.. ... sx 7L^n,; ,,et' Ck �F exs.rr, '.: 1 — _ r»+,-•x... — �.�._. K¢•e'-•.'+ ......� .. ti'r r .X•�� P <a. L.,•• ' 'w' :.y:. ..v...�` 1..*'s4•M. ,CL.. ..�-s':a1�1'� __ � "'S:a�. _. .......__ - _...�-- ,�"., ,.:. -. �,tl'n+ N,, r. :` � ;(' k s, � t i.gr� ,..- �.� - _. �- {.�•^..'Y't."..y',.n..rv.. .,.r- � .. , .. � r. ' '1• .: ,a.. -. ,. .. -. t --�' .. rc s.i;; '''`� +a'�'r�P•.,,,,-,~ �j .y +"�`t ::c•-, �-'�--�:"� e .>'S: J w. .. .... _. ',..r t : h. '.T .. -.. :: y •,a.rE 'i'1 �" FK ly'.tvF��_�5��"" - ";( s :. t. .. t't .z. % 1,, i.ggrr,(,rA X« f.+c�{,-•C>A• �� •µ.`�' ar'•� ,�I�� �,. _ :. 1z { FG-"��� d.•.r.> :X 1. �� - - - - .., ,.{.., ',s. a �. , ..., .. .-:.. ,.,.: .. .-:.. .,ti. ev I- +... ..�' � i °�')•rr". S �t.•�,,f :�'"Ii� •q,. •5, 3� _ .i .,^" t E -` `r•^,Y-4�',�:3 I•r�^l.< f.. S Y. N'4 � �C�vr. C ;..... ,tom. ..-, .- -.,,,..•.,.�....r:.., 'a ^6•L Pt'aeb.r 7A, ; ".,. r S. r l•�t i �. J;_�,� `„tt t: '... .1 .c, - .;.',ter r:,9� .y� e�:ss< :E: c .,. ,;.;,f zt> •r H a t � y „ .. E ••" c. ^.:r .,..r»...t.'-' .a i^".:r ":i S ri-;c .._ - J' .. Y:., { b '`r•'GS` Y. L:< �Ytn..q � .-S Fn'` :>:'•,n.� 'L r'•'A,. :�.9 7' ^� .i. : - ,c s+. /'�` ra_a,G..a'. ?.:,ky °r`L.Y._,11•.w'•.t .Z�'s`a =d,, _(`,.. - .. ..- '. ....•Y.,- - .. .,.:,'r k'.. ��_ ,,,;,�'_.- ... - -.:. .r�._:�ce:i...:�aGr..± '�.'�r,: _5-•i' i, }} .i� *.•,+,C '^,�'`x�-E": .`t,'�ele 2• _ h ,�:.•. , + 0 EXISTING DOOR TO BE REMOVED AND INFILL WITH 2 LAYERS OF j" GYP ON STORAGE SIDE, AND 1 LAYER OF r GYP EXISTING VENT ON RETAIL SIDE. TO REMAINWSA KEY TAG DISPLAY — (WITH NEW SIGNS ABOVE) FRAME OPENING TO BREAKROOM. NO DOOR TO BE INSTALLED. X o I L L I A M STARCK 3'_4" BREAK ROOM o ARCHITECTS , INC (NEW) M COVE STREET' COUNTERS .•.:..:::..-::.:.-......... INSTALL NEW COUNTER FAI1 RIVER CIA 02T20 o (NEW LOCATION) srs' �1>Ut 11 Rs>I S'`<. INK` TOP WITH SINK T:508.679.5733 12" F:50s672.85% � 1 CFS MANAGERS 10 DORRkNC7E PROVIDENCE. 02903 700 w OFFICE(NEW) T:401.519.3647 F:401.519-WI INSTALL NEW 36" DOOR AND FRAME IN NEW OPENING W W WSTARCKARCHrrECIS.COM REMOVE EXISTING DOOR & FRAME. INFILL OPENING 0 EXISTING J USING (2) LAYERS OF 5/8' GYP ON BOTH SIDES. E SIDE ¢ �_ SHOWROOM —� r o WALK r ADA WOMEN S DOOR SCHEDULE o AND = 5'-°" RESTROOM 77 — RAMP ` NEW DOOR FRAME e ~U- N ( ) SIZE DETAIL HARDWARE g` 2 TAG TYPE SET NO. NOTES MAIL Pr'ATL a ® WD HGT THK HEAD JAMB SILL 5-0 ADA MEN'S 1 A 3'-0" 6'-8" 1 3/4" WD. H.M. 4/A.1 4/A.1 5/A.1 HWS 1,2 1 2. 1/2" GWi3 0 RESTROOMco — - o INSIDE WALL FINISH FLUSH ` �/O (NEW) 2 A 3'-0" 7'-0" 1 3/4" INS. H.M. INS. H.M. 15/A.1 HWS-3 o \ DOOR AS SCHEDULED o WITH COLUMN FACE oREMARKS 1. PAINT DOOR AND FRAME. 2. DOOR TO HAVE 1" UNDERCUT ---- 13 CfS i INSTALL NEW 36" DOOR AND - -SEALANT, EA SIDE ­1111 DOOR FRAME BEYOND g ELEC. PANEL FRAME IN NEW OPENING HARDWARE SET 1 MANAGER'S OFFICE HARDWARE SET 2 RESTROOMS HARDWARE SET 3 - EXTERIOR HALLWAY x `" 3'-4° o 0 1-1/2 - PR. HINGES CB179 4-1/2x4-1/2x26D 1-1/2 - PR. HINGES CB179 1-1/2 - PR. HINGES CB179 W - HALLWAY , i CARPET TILE ROOM (EXISTING) 1 1 �1 NRP (STANLEY) 4-1/2x4-1/2x25D NRP (STANLEY) 4-1/2x4-1/2x26D NRP (STANLEY) H.M. DOOR FRAME (NEW) 1 - KEYLOCK 1 - RESTROOM PRIVACY 93K CL S3 26D 1 - LOCK BY OWNER f '� i 1 - CLOSER 8616ARP SNB1 685 DORMA 1 -`CLOSER 8616ARP SNB1 589 DORMA DO NOT INSTALL CLOSER EXISTING WINDOWS EXISTING EXISTING ENTRANCE _ -�� ( ) ( ) METAL CARPET STRIP DOOR NEW XISTING 1 - WALL STOP #409x32D (DORMA) 1 - WALL STOP l409x32D (DORMA) G���o )E,Y �A� DOOR DOOR AS SCHEDULED o G DOOR A VINYL TILE o r/IJ Q9 2 DOOR ADJUSTMENT NOTES (INTERIOR DOORS) o INSTALL NEW 36" CLOSING SPEED SHALL BE 6 SECONDS MIN FROM AN OPEN POSITION OF 90 DEGREES TO �w " 0. 31005 DOOR AND FRAME IN FULLY CLOSED; AND 5 SECONDS MIN FROM AN OPEN POSTION OF 90 DEGREES TO A NEW OPENING 5'-2" 4'-4" EXISTING TEL/COM BOX POSITION OF 12 DEGREEE FROM THE LATCH. (DOES NOT APPLY TO FIRE DOORS) 1" ASSACIjIj CL f t of.ate r • MAXIMUM FORCE TO OPEN SHALL BE 5 L65 2 INTERIOR JAMB/ HEAD DETAIL 3 THRESHOLD DETAIL 1 PROPOSED INTERIOR FIT-UP PLAN - A-1 SCALE: N.T.S.A-1 SCALE. 1/8 1 0 0 0 I s `o o o 0 o , CL U. d `oOf co MASS AAB REQUIREMENTS ® z < o z QCD LL. � N b � I, 12" FROM 60" MIN \ 3 111 (/) O 42" REAR WALL _ - - � U; m W a f WALL TO LAv SIGNAGE NOTES _ ., _ iP- RfJ AN RAI � _ _�iZ. 0 6 Ll1:D�HArcA�TERS AND PiCiORIAL SYMBOL SlGtra P ..._• - � 5 ! � � -( lCTOGRAiv�S f. � � , A_, 42 LETTER'S AND NUMERALS H i� F �„: (/� g S ALL BE RAISED 1/32 .,UPPER CASE, SANS SERIF TVE AND &�: LL BE A OMPAN�ED WITH (,BADE 2 BRAILLE. 4 —� Q Q °O 1 C RAISED CHARACTERS SHALL BE AT LEAST 5/8, HIGH, BUT NO HIGHER THAN 2'. PICTO�RA AS ON ADA RESTROOM SIGNS SHALL BE - Q W Z A-' A-' A-' X x"'`" u / ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICr GRAM: THE BORDER DIMENSION OF THE im Z 7 / E3 Z ¢ L5� a ��� c , „ o \ A-, i� N PICTOGRAM SHALL BE 6" MINIMUM IN HEIGHT. ® Q d' Q ------- FINISH AND CONTRAST. Lo } _ _ THE CHARACTERS AND BACKGROUND OF ADA RESTROOM SIGNS SHALL BE OF NON--GLARE FINII H. CHARACTERS AND SYMBOLS SHALL HAVE S Lu � J CONTRAST WITH THE BACKGROUND.- EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. 7" (MIN) 18 NOTHING TO BE INSTALLED �`1 3-0" MOUNTING LOCATION AND HEIGHT _ O 9 MAX ABOVE GRAB BARS. WHERE PERMANENT IS PROVIDED FLIP, RESTROOMS AND SPACES, SiC,!•!S SHALL BE INSTALLED ON THE WAIL ACJACENT TO THE LATCH SIDE OF THE DOOR, AT DOUBLE LEAF ODORS SIGNS SHALL BE PLACED ON THE NEAR'-ST ADJACENT WALL. MOUNTING LOCATION o 5 WOMEN`S RESTROOM-NEW �6 WOMEN'S RESTROOM 7 WO MEN'S RESTROOM a �°OMEN'S RESTROOM SHALL;BE 60" AFF TO THE CENTER LINE OF THE SIGN. MOUNTING LOCATION FOR SUCH SIG SAGE SHALL BE SO THAT A PERSON MAY 0. APPROACH WITHIN 3 IN. OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF DOOR 18" X 18' OF o A-1 SCALE: 1/4" = 1'-0' A-1 SCALE: 1/4' = 1'-0' A-1 SCALE: 1/4' = 1'-0" A-1 SCALE 1/4" = f-0' / s CLEAR SPACE CENTERED ON THE TACTILE CHARACTERS). SIGNS WITH TACTILE OHARACTERS ARE''pjU,L ON I'.Ht PUSH 9f>E OF DOORS NiTH A-, I CLOSERS AND WITHOUT HCLD-OPEN DEVICES 12 10 SYMBOLS OF ACCESSIBILITY 1..1� I A t1 A-� - CL FACILITIES AND ELEMENTS REQUIRED TO BE IDENTIFIED AS ACCESSIBLE SHALL USE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. 8 / I 60" MIN // F 42" REARWAALL - — — — WALL TO LAV - m / o m S-6„ / 6• a 13 ,: CL ✓f o REVISIONS: M� IX Z ° x 0 8/05/16 CLARIFICATIONS TO AAB 'SPACE � N _ J I \ N r7 _ 18" NOTHING TO BE INSTALLED 11 3'-0" A4 7° (MIN) ABOVE GRAB BARS 9 MAX 45 9 MEN'S RESTROOM to MEWS RESTROOM 11 MEWS RESTROOM (�kllEN-S RESTROOM to ACCESSIBILITYNAL S o� A-1 SCALP: 1/4" 1'-O" A-1 SCALE 1/4" = V-0' A-1 SCALE: 1/4'= 1'-D' SCALE: o " 4 WOMEN &MEN RESTROOMS PLAN FINISH a • o A-1 SCALE: 1/4'= 1'-D" FLOOR - ACCESSIBLE RESTROOM SIGNS s E o 54°(MIN) 42"MIN TO 72"(MIN) TO ` 6" MAX FROM ---- NEAREST E NEAREST TOILET ROOM ACCESSORY SCHEDULE SIDE WALL 42°(MIN)MASS 12 FROM FIXT o 18" WALL./FIXT WALL/ REAR WALL 42" ,< EXT WALL EXISTING CMU WALL ITEM DESCRIPiION(OR APPROVED EQUAL) ---_21 42" MIN TO TYP 42" GRAB BAR BRADLEY 8120-001420 ETCHED ^,^< 4 x „ Z Z^ ---� —. ;� „ NEAREST m SCALE: AS NOTED (2) 6'x3�%5/16 CONT SEALANT c !s WALL/FIXT - �- - DATE: 07/19/16 ZINC-COATED SOAP DISPENSER GRAINGER (GOJO) 5W625 z €z " DIA. GALV. THRU - N, �n o_ �,� z NOTHING MTD WITHIN CL ANGLES MIN. 3" „ RESTROOM MIRROR BRADEX 781-1836 M ,., =� r., � 7 i, 9 BEARING EA. END BOLTS (TYP. OF 4) FINISH 1 " OF GRAB BARS _- o DRAWN BY: JPA INSTALL NEW / \ I INSTALL NEW LAVATORY: Z5354 (WHITE): VITREOUS CHINA WALL-HUNG LAVATORY, PROViDEC:, WITH WALL HANGER, FAUCET HOLES FLOOR REAR GRAB BAR SIDE GRAB BARS WA E JOB NUMBER:iERLOS.T 16-044 RESTROOM SIGN RESTROOM SIGN 10 14G BETWEEN C - ON 4" CENTERS, REAR OVERFLOW; PROVIDE WITH FOLLOWING TRIM: ZURN Z8743-PC GRID STRAINER, Z8700 P-TRAP NOTHING MTD WITHIN ° / PLATE Y &LIN �N I5H CONTROL MUST BE DRAWING NAME: / MASONRY & LINTELS AND Z8946-1-NT TRAP & SUPPLY WRAP; FAUCET: DELTA 520-WFMPU (OR SIMILAR) WITH RP19754 AERATOR; LESS 1 "-0F GRAB BARS 1; UPEN SIDI: OF TANK POP-UP DRAIN AND LIFT HOLE IN POLISHED CHROME. 1-1/4" TAILPIECE. PROVIDE 3/8" WALL SUPPLIES WITH STOP. SHIM AS REQ'D- TOP OF OPENING INSULATE ALL EXPOSED PLUMBING/VALVES AND /SHARP/ABRASIVE OBJECTS / INTERIOR ' ,��� INSULATE EXPOSED PLBG VALVES- o AND SHARP/ABRASNVE OBJECTS 1 o =� ! // r- CONT SEALANT & BACKER WATER CLOSET: Z5550-RH (LH): 1.6 GPF ADA ELONGATED RIM, SIPHON JET l N0-PIECE TOILET, COMPLETE WITH � a o ROD (BOTH SIDES) POLISHED CHROME FLUSH ACTUATOR, COMMERCIAL STANDARD PLASTIC OPEN FT,)ONT TOILET SEAT: Z5956SS-EL LEVER OR AUTO FAUCETS s` s © `-' FIT-UP \ SIPHON ACTION BOWL AND SELF-TOP TANK, LOW CONSUMPTION TOILET, FLUSHES ON 1.6 GAL. OF WATER. FLUSH g I DOOR AS SCHED METAL FRAME GROUT MECHANISM SHOULD BE ON THE OPEN SIDE. 7 c FILLED soup 7 (MIN) DRAWING NUMBER: 18° CLEAR SPACE - 9 (MAX) KNEE r - ( > o �`�-t� x w & TOE -- Q 13 WOMEN RESTROOM ENTRANCE 14 MEN'S RESTROOM HALLWAY 15 HEAD DETAIL @ NEW EXTERIOR DOOR cLEARaNC � ' W= o NOTE: A-1 SCALE: 1/4' = 1'-0" A-1 SCALE: 1/4"= 1'-0' A-1 SCALE 1-1/2'= 1'-0' ' 7+C 1. REFER TO MOUNTING HEIGHT DETAILS FOR SPECIFIC 11 TOILET PAPER DISPENSER DIMENSIONAL INFORMATION SER LAVATORY MIRROR UNIT o 2. G.C. SHALL INSTALL SOLID WOOD BLOCKING AS A� 1 REQUIRED AT ALL WALL-MOUNTED RESTROOM ;'OkVA, COMPONENTS COMMENTS: SHOP DRAWINGS/DEFERRED STRUCTURAL SUBMITTALS (con't) CONCRETE/MASONRY ANCHORS GENERAL NOTES: DESIGN CRITERIA 1. ALL STRUCTURAL WORK SHALL CONFORM TO THE STRUCTURAL DRAWINGS AND SPECIFICATIONS AND MEET THE 7. OTHER SUBMITTALS MAY BE REQUIRED PER THE SPECIFICATIONS OR THE SEPARATE NOTES CONTAINED HEREIN. 1. EXPANSION BOLTS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE KWIK BOLT TZ(ICC ESR-1917)AS REQUIREMENTS OF THE 2009 INTERNATIONAL BUILDING CODE(IBC)AND THE APPLICABLE BUILDING CODE AMENDMENTS.THE I MANUFACTURED BY THE HILTI CORP.OR AN APPROVED EQUIVALENT IN STRENGTH AND EMBEDMENT. ARCHITECTURAL DRAWINGS SHALL GOVERN ALL DIMENSIONS. 8. TEMPORARY OR PERMANENT SYSTEMS OR FRAMING MEMBERS THAT ARE NOT SPECIFICALLY DESIGNED,DETAILED,OR SPECIFIED IN THE CONTRACT DOCUMENTS BUT ARE REQUIRED TO COMPLETE THE FINISHED STRUCTURE,SHALL BE 2. ADHESIVE ANCHORS SHALL BE HIT-RE 500-SD(ICC ESR-2322)INTO CONCRETE AND HIT HY 150 MAX(ESR-1967)INTO 2. OCCUPANCY CATEGORY: I DESIGNED AND DETAILED BY OR UNDER THE DIRECTION OF A QUALIFIED PROFESSIONAL ENGINEER. ALL REQUESTED MASONRY AS MANUFACTURED BY THE HILTI CORP.OR AN APPROVED EQUIVALENT IN STRENGTH AND EMBEDMENT. SUBMITTALS FOR THESE SYSTEMS OR FRAMING MEMBERS SHALL BE SIGNED AND SEALED BY SAID QUALIFIED 3. ROOF LIVE LOADS: PROFESSIONAL ENGINEER. 3. ALL ANCHORS SHALL BE INSTALLED WITH STEEL WASHERS. a. BASIC ROOF LIVE LOAD 5 PSF 9. ALL SIGNED AND SEALED SHOP DRAWINGS AND/OR CALCULATIONS THAT ARE REQUIRED TO BE SUBMITTED FOR REVIEW 4. WHEN USING ADHESIVE ANCHORING SYSTEMS THE MANUFACTURER SHALL SUPPLY THE ANCHOR AND ADHESIVE,UNLESS 4. SNOW LOADS(CANOPY ROOF IS NOT DESIGNED FOR SNOW LOADS. THE FABRIC ROOF SHOULD BE REMOVED WHEN SNOW SHALL BE DONE BY OR UNDER THE DIRECTION OF A QUALIFIED PROFESSIONAL ENGINEER. OTHERWISE NOTED. OCCURS.):a. GROUND SNOW LOAD(Pg) 45 PSF 10. A QUALIFIED PROFESSIONAL ENGINEER IS A PROFESSIONAL ENGINEER WHO IS LEGALLY REGISTERED AND LICENSED TO 5. ALL ALTERNATE PRODUCTS SHALL HAVE A CURRENT ICC EVALUATION REPORT. ., b. FLAT ROOF SNOW LOAD(PQ 30 PSF PROVIDE ENGINEERING SERVICES IN THE JURISDICTION IN WHICH THE PROJECT IS LOCATED AND WHO IS EXPERIENCED IN c. SNOW EXPOSURE FACTOR,Ce 1.0 PROVIDING ENGINEERING SERVICES RELATED TO THE WORK SUBMITTED. SAID ENGINEER SHALL BE CAPABLE OF 6. ANCHORS INSTALLED INTO MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS UNLESS OTHERWISE NOTED. IF d. SNOW LOAD IMPORTANCE FACTOR,Is 0.80 PERFORMING DESIGN AND DETAILING USING RATIONAL ENGINEERING DESIGN PRACTICES BASED ON STANDARD PRACTICES GROUTED CELLS ARE NOT ENCOUNTERED,BREAK INTO CELL AND GROUT SOLID 8". e. THERMAL FACTOR,Ct 1.2 IN ACCORDANCE WITH THE CONTRACT DOCUMENTS,THE BUILDING CODE,AND ALL APPLICABLE BUILDING CODE AMENDMENTS. 7. ALL ANCHORS SHALL BE APPROVED FOR USE WITH CRACKED CONCRETE AND CONFORM TO CURRENT ICC ES REPORT 5. WIND LOADS: (ICC-ES AC193 FOR MECHANICAL ANCHORS AND ICC-ES AC308 FOR ADHESIVE ANCHORS). a. BASIC WIND SPEED(3-SECOND GUST) 100 MPH FOUNDATION DESIGN b. WIND IMPORTANCE FACTOR,Iw 1.0 8. INSTALL ALL ANCHORS IN STRICT ACCORDANCE WITH ALL APPLICABLE ICC-ES AND BUILDING CODE REQUIREMENTS. ALL c. WIND EXPOSURE "C" 1.' ASSUMED GEOTECHNICAL INFORMATION: ANCHOR SPACING,EMBEDMENT,EDGE DISTANCE,AND INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER d. COMPONENTS AND CLADDING PRESSURE a. ALLOWABLE SOIL PRESSURE 1,500 PSF RECOMMENDATIONS.REFER TO SECTIONS AND DETAILS ON THE DRAWINGS FOR ADDITIONAL INFORMATION. • DESIGN BY QUALIFIED DESIGN PROFESSIONAL IN ACCORDANCE WITH ASCE 7. SUBMIT LOADS FOR REVIEW y �. FOOTINGS SHALL BEAR AT LEAST 48"BELOW LOWEST ADJACENT FINISHED GRADE. FOOTING DEPTHS/ELEVATIONS SHOWN 9. ALL PERSONNEL INSTALLING MECHANICAUADHESIVE ANCHORS SHALL BE TRAINED BY THE PRODUCT MANUFACTURER ON 6. EARTHQUAKE LOADS: i ON THE DRAWINGS ARE MINIMUM AND FOR GUIDANCE ONLY;THE ACTUAL ELEVATIONS OF FOOTINGS MUST BE ESTABLISHED PROPER INSTALLATION TECHNIQUES. TRAINING DOCUMENTATION FROM THE MANUFACTURER SHALL BE AVAILABLE UPON a. SEISMIC IMPORTANCE FACTOR,le 1.0 BY THE CONTRACTOR IN THE FIELD. REQUEST. 1 b. MAPPED SPECTRAL RESPONSE ACCELERATION,Ss 25.0°fog C. MAPPED SPECTRAL RESPONSE ACCELERATION,S1 6.40°/ug 3. ALL FOOTINGS SHALL BEAR ON UNDISTURBED,FIRM NATURAL SOIL OR COMPACTED FILL CAPABLE OF SUPPORTING THE STRUCTURAL STEEL d. SITE CLASS(ASSUMED) D DESIGN BEARING PRESSURE NOTED HEREIN. e. SPECTRAL RESPONSE COEFFICIENT,SDs 26.7°fog 1. ALL STRUCTURAL STEEL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND APPLICABLE ISPECTRAL RESPONSE COEFFICIENT,SD1 10.2%g 4. ALL SOIL SURROUNDING AND BENEATH ALL FOOTINGS,SLABS,ETC,SHALL BE PROTECTED AGAINST FROST OR FREEZING AMENDMENTS AND WITH THE"SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS"(1989 EDITION)OF THE AMERICAN g. SEISMIC DESIGN CATEGORY B DURING CONSTRUCTION. INSTITUTE OF STEEL CONSTRUCTION. REVISIONS: h. BASIC SEISMIC-FORCE-RESISTING SYSTEM C4(PER ASCE 7 TABLE 12.2-1) f i. DESIGN BASE SHEAR 0.076*W KIPS 5. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR FOUNDATION DESIGN WHEN A GEOTECHNICAL REPORT IS NOT 2. ALL STRUCTURAL STEEL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND APPLICABLE THE ARCHITECT ANDlOR ENGINEER. AMENDMENTS AND WITH THE 13TH EDITION OF THE"STEEL CONSTRUCTION'MANUAL"OF THE AMERICAN INSTITUTE OF STEEL J. SEISMIC RESPONSE COEFFICIENT,Cs 0.076 PROVIDED TO V k. RESPONSE MODIFICATION FACTOR,R 3.5 i CONSTRUCTION. 6. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ONSITE SOIL CONDITIONS. 7. SEE PLANS FOR ADDITIONAL LOADING CRITERIA. 3. GRADE OF STEEL i.' THE CONTRACTOR SHOULD EMPLOY A PROFESSIONAL GEOTECHNICAL ENGINEER TO INSPECT THE FOUNDATIONS AND a. OTHER SHAPES,PLATE,AND BARS ASTM A36 GENERAL CONDITIONS BEARING LEVELS AND VERIFY THAT THE MATERIAL ON WHICH THE FOUNDATIONS WILL BEAR HAS AT LEAST THE ABOVE b. HOLLOW STRUCTURAL SHAPES(HSS) ASTM A500,GRADE B NOTED CAPACITY AND GIVE RECOMMENDATIONS FOR SUBGRADE PREPARATION. STRICTLY FOLLOW GEOTECHNICAL c. STEEL PIPE ASTM A53 TYPE E,GR.B 1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS OF ALL OTHER DISCIPLINES AND ENGINEER'S RECOMMENDATIONS FOR SUBBASE AND FOOTING BEARING MATERIAL AND PREPARATION AS REQUIRED. d. GALVANIZED STRUCTURAL STEEL SPECIFICATIONS.THE CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO SLEEVES,CHASES, • STRUCTURAL SHAPES AND RODS ASTM Al23 HANGERS,INSERT ANCHORS,HOLES,AND OTHER ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK. B. IMMEDIATELY NOTIFY THE ENGINEER AND/OR ARCHITECT IF UNSUITABLE SOIL OR SOIL CONDITIONS AT VARIANCE WITH THE BOLTS,FASTENERS AND HARDWARE ASTM A153 GEOTECHNICAL REPORT IS DISCOVERED AT THE FOOTING ELEVATIONS SPECIFIED. e. ANCHOR RODS ASTM F1554,GR.36 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND REGULATIONS DURING THE f. THREADED ROD ASTM A36 WORK.THE ENGINEER WILL NOT ADVISE ON,NOR ISSUE DIRECTION,AS TO SAFETY PRECAUTIONS AND PROGRAMS. 3. THE EXISTENCE OF UNDERGROUND STRUCTURES AND/OR UTILITIES IS NOT KNOWN. IT IS THE CONTRACTOR'S ' RESPONSIBILITY TO COORDINATE WITH THE OWNER OR NECESSARY AUTHORITIES THE LOCATIONS OF ALL EXISTING 4. ALL FIELD CONNECTIONS SHALL USE BOLTS,UNLESS OTHERWISE NOTED.ALL SHOP AND FIELD INSTALLED BOLTS SHALL BE 3. METHODS,PROCEDURES AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR.THE UNDERGROUND STRUCTURES AND/OR UTILITIES. 3/4"DIA ASTM A325 TYPE N BOLTS IN STANDARD HOLES,AND SNUG TIGHT,UNLESS OTHERWISE NOTED.ALL BOLTED CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY AND STABILITY OF THE CONNECTIONS SHALL HAVE 2 BOLTS MINIMUM,UNLESS OTHERWISE NOTED. STRUCTURE AT ALL STAGES OF CONSTRUCTION.THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR 0. WHERE FOOTINGS ARE IN CLOSE PROXIMITY OF SEWERS,DRAINS,CONDUITS,PIPES,ETC.,THE BOTTOM OF FOOTING SHALL STABILITY UNDER THE FINAL CONFIGURATION ONLY. BE SET AT OR BELOW THE INVERT ELEVATION OF THE ADJACENT ELEMENT. 5. HARDENED WASHERS CONFORMING TO ASTM F436 SHALL BE USED AT A325 BOLTS AND A490 BOLTS USED IN FRICTION CONNECTION AND OVERSIZED AND SHORT SLOTTED HOLES. 5/16"THICK PLATE WASHERS OF STRUCTURAL GRADE 4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO FABRICATION OF ANY,STRUCTURAL EAST-IWPLACE CONCRETE MATERIAL SHALL BE USED AT LONG SLOTTED HOLES. WASHERS SHALL HAVE A SIZE SUFFICIENT TO COMPLETELY COVER COMPONENTS. IMMEDIATELY NOTIFY THE ENGINEER AND/OR ARCHITECT OF ANY DISCREPANCIES FOUND DURING FIELD THE SLOT AFTER INSTALLATION. VERIFICATION.THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING TO OBTAIN ENGINEER'S CLARIFICATION BEFORE ALL REINFORCED CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND APPLICABLE COMMENCING THE WORK. AMENDMENTS AND THE"BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE"(ACI 318)OF THE AMERICAN 6. ALL MODIFICATIONS REQUIRED FOR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWINGS,AND MADE DURING SHOP CONCRETE INSTITUTE. FABRICATION.FIELD BURNING OF STRUCTURAL STEEL IS PROHIBITED. z 5. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ENGINEER AND/OR ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OF ANY STRUCTURAL COMPONENTS. ALL CHANGES REQUIRE THE WRITTEN APPROVAL OF THE ALL REINFORCED CONCRETE MIX DESIGNS SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE AND 7, ALL WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1"STRUCTURAL WELDING CODE-STEEL".WELDING FILLER METAL a ENGINEER AND/OR ARCHITECT. UNAUTHORIZED DEVIATIONS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. APPLICABLE AMENDMENTS AND THE"SPECIFICATIONS FOR STRUCTURAL CONCRETE"(ACI 301)OF THE AMERICAN SHALL BE AWS A5.1 OR A5.5 E70XX LOW HYDROGEN ELECTRODES.WELDERS SHALL BE AWS CERTIFIED.SUBMIT COPY OF I I I I ! I I { CONCRETE INSTITUTE. ALL CERTIFICATIONS TO THE ENGINEER.SURFACES TO BE WELDED SHALL BE WIRE BRUSHED CLEAN BEFORE WELDING. z 6. THE CONTRACTOR SHALL SHORE OR CRIB THE STRUCTURE FOR ALL CONSTRUCTION LOADS WHICH EXCEED THE NOTED DESIGN LOADS. DO NOT APPLY ANY ERECTION OR CONSTRUCTION LOADS UNTIL STRUCTURAL FRAMING IS PROPERLY 3 ALL REINFORCING STEEL FABRICATION AND PLACEMENT SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING CODE S. ALL EXTERIOR METAL FABRICATIONS EXPOSED TO WEATHER SHALL BE GALVANIZED,UNLESS OTHERWISE NOTED. w CONNECTED TOGETHER AND UNTIL ALL TEMPORARY BRACING IS IN PLACE. AND APPLICABLE AMENDMENTS AND THE"MANUAL OF STANDARD PRACTICE"(CRSI MSP-1)OF THE CONCRETE REINFORCING o I I { I I I I I STEEL INSTITUTE AND THE"SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS"(ACI 301)AND"DETAILS AND SPECIAL STRUCTURAL INSPECTIONS 7. ALL STRUCTURAL WORK THAT IS COMPOSED OF COMPONENTS DESIGNED BY OTHERS SHALL BE IN ACCORDANCE WITH THE DETAILING OF CONCRETE REINFORCEMENT"(ACI 315)OF THE AMERICAN CONCRETE'INSTITUTE. MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS AND SUPERVISED BY THE MANUFACTURER'S REPRESENTATIVE(S) 1, THE OWNER WILL HIRE.AN INSPECTION AGENCY OR RETAIN THE ENGINEER OF RECORD TO PERFORM ALL REQUIRED N ' � 00 DURING THE MANUFACTURING,DELIV ERY,RY HANDLING STORAGE AND ERECTION AS REQUIRED. 4. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE(144 PCF+)CONFORMING TO ASTM C94 WITH ALL CEMENT SPECIAL INSPECTIONS AND TEST. PROFESSIONAL SEAL: ' CONFORMING TO ASTM C150,TYPE I OR II.MAXIMUM AGGREGATE SIZE SHALL BE 1-1/2"FOR FOOTINGS AND 3i4"FOR WALLS �' ` �.3 �• i -^--' CONFORMING T A 2. SPECIAL STRUCTURAL INSPECTIONS SHALL BE CONDUCTED AND DOCUMENTED AS PER CHAPTER 17 OF THE IBC AND ALL m.... : 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.WHERE CONDITIONS ARE NOT SPECIFICALLY ,.._ AND SLABS,CON 0 G 0 ASTM C33 SHOWN SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED,SUBJECT TO APPROVAL BY THE ENGINEER. APPLICABLE AMENDMENTS FOR THE FOLLOWING ITEMS OR AS REQUIRED BY THE BUILDING OFFICIAL: � 5.' ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH(fc)AT 28 DAYS,SLUMP AND MAXIMUM WATER/CEMENT C14 00 9. ALL ASTM AND OTHER REFERENCES ARE PER THE LATEST EDITIONS OF THOSE STANDARDS,UNLESS OTHERWISE NOTED. RATIO REQUIREMENTS: a. STEEL CONSTRUCTION < L b. ALL CONCRETE 3000 PSI 2"-4"SLUMP* W/C RATIO=.58 • STEEL CONSTRUCTION MINIMUM SPECIAL INSPECTION:GENERAL CONFORMANCE AND BOLTS ONLY;ALL WELDING c) E AND OPERATIONS FOR ALL WORK THAT OCCURS ADJACENT TO AN EXISTING TO BE PRE-QUALIFIED SHOP WELDS WHERE POSSIBLE,PERFORMED IN A SHOP AND BY A WELDER THAT IS AWS �jy� kdq��� 10. COORDINATE ALL CONSTRUCTION ACCESS O STRUCTURE AS NECESSARY TO AVOID DISRUPTION TO SAID STRUCTURE. 6.' OBTAIN EACH TYPE OF CEMENT OF THE SAME BRAND FROM THE SAME MANUFACTURER'S PLANT,EACH AGGREGATE FROM CERTIFIED. ALL STEEL FABRICATORS THAT ARE NOT PRE-APPROVED BY THE BUILDING OFFICIAL SHALL BE t cQ' HRL. ° I ONE SOURCE,AND EACH ADMIXTURE FROM THE SAME MANUFACTURER. INSPECTED IN ACCORDANCE WITH SECTION 1704.2 OF THE IBC. D - ►< ` 11. ALL STRUCTURAL CONSTRUCTION DOCUMENTS(DRAWINGS,DETAILS,CALCULATIONS,AND ALL OTHER STRUCTURAL b. CONCRETE CONSTRUCTION 5933 r ,.a . . CO INFORMATION)PROVIDED ARE THE PROPERTY OF U-HAUL INTERNATIONAL/AMERCO REAL ESTATE(U-HAUL)AND ARE FOR USE 7. ALL CONCRETE EXPOSED TO WEATHER SHALL HAVE ENTRAINED AIR IN ACCORDANCE WITH SECTION 1904 OF THE IBC. c. ANCHOR BOLTS IN PRE-DRILLED HOLES IN CONCRETE OR IN MASONRY o �,o ON THIS PROJECT ONLY. ANY OTHER USE OF THE STRUCTURAL CONSTRUCTION DOCUMENTS IS STRICTLY PROHIBITED d. SITE SOIL CONDITIONS(AS REQUIRED;SEE FOUNDATION DESIGN NOTES) WITHOUT THE WRITTEN PREMISSION OF U-HAUL. 8. FOR AIR ENTRAINED CONCRETE-MAXIMUM W/C RATIO=.44 -� - 0� d �� s tom+ 3. ALL SPECIAL INSPECTIONS SHALL BE CONDUCTED BY A QUALIFIED SPECIAL INSPECTOR AS DETERMINED BY THE BUILDING o z 12. THE SCOPE OF SERVICES CARRIED OUT BY U-HAUL DOES NOT INCLUDE A FIELD REVIEW DURING CONSTRUCTION UNLESS 9. ALL GROUT SHALL BE NONMETALLIC SHRINKAGE-RESISTANT GROUT PROVIDED BY A MANUFACTURER APPROVED IIN WRITING OFFICIAL AND/OR PERFORMED UNDER THE SUPERVISION OF THE ENGINEER OF RECORD. OTHERWISE AGREED UPON IN WRITING,THE CONSTRUCTION DOCUMENTS ARE ISSUED WITH THE UNDERSTANDING THAT THE BY THE STRUCTURAL ENGINEER AND INSTALLED AND MIXED PER THE MANUFACTURER'S RECOMMENDATIONS AND o C14 CONTRACTOR IS SOLELY RESPONSIBILITY FOR VERIFING ALL WORK IS CARRIED OUT IN ACCORDANCE WITH THE INSTRUCTIONS. ALL GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH ft)AT 28 DAYS EQUAL TO 5000 PSL 4. A STATEMENT OF SPECIAL STRUCTURAL INSPECTION IN ACCORDANCE WITH SECTION 1705 OF THE IBC SHALL BE SUBMITTED -� CONSTRUCTION DOCUMENTS AND THAT ANY DISCREPANCIES OR OMISSIONS WILL BE BROUGHT TO THE IMMEDIATE TO THE BUILDING OFFICIAL PRIOR TO BEGINNING OF ANY SPECIAL STRUCTURAL INSPECTIONS BY THE SPECIAL INSPECTOR. ARCHITECT LOGO: ATTENTION OF THE ARCHITECT AND ENGINEER. 10. REINFORCEMENT: a. DEFORMED BARS ASTM A615,GRADE 60 5. SPECIAL STRUCTURAL INSPECTION REPORTS SHALL BE FURNISHED TO THE BUILDING OFFICIAL AND THE ENGINEER OF 13. IF DRAWINGS AND CALCULATIONS ARE PROVIDED ELECTRONICALLY;COPIES OF THE ORIGINAL CONSTRUCTION DOCUMENTS b. GALVANIZED REINFORCEMENT ASTM A767,CLASS II RECORD IN ACCORDANCE WITH SECTION 1704 OF THE IBC. AS DESIGNED BY U-HAUL HAVE BEEN RETAINED BY U-HAUL. U-HAUL IS NOT RESPONSIBILITY FOR ANY SUBSEQUENT CHANGES TO THE REPRODUCIBLE ORIGINAL CONSTRUCTION DOCUMENTS(I.E.DOCUMENTS PROVIDED ELECTRONICALLY)WHICH ARE 11. REINFORCING STEEL SHALL HAVE THE FOLLOWING MINIMUM CLEAR CONCRETE COVER UNLESS OTHERWISE NOTED: NOT MADE OR OTHERWISE COMMUNICATED IN WRITING BY U-HAUL a. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" b. CONCRETE SURFACES IN CONTACT WITH SOIL OR EXPOSED TO SHOP DRAWINGS/DEFERRED STRUCTURAL SUBMITTALS EARTH OR WEATHER (#6 BARS OR LARGER) 2" (#5 BARS OR SMALLER) 1-1/2" I 1. THE CONTRACTOR SHALL SUBMIT A MINIMUM OF THREE COPIES OF THE FOLLOWING SHOP DRAWINGS(MAXIMUM SCALE 1/8:= c. COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1-1/2" V-0")TO THE ARCHITECT/ENGINEER PRIOR TO THE FABRICATION OF ANY STRUCTURAL COMPONENTS(ONE COPY TO BE d. CONCRETE SURFACES NOT IN CONTACT WITH SOIL OR RETAINED BY THE ARCHITECT AND ENGINEER). AS A MINIMUM,ALL SHOP DRAWING SUBMITTALS SHOULD INCLUDE PLANS, EXPOSED TO WEATHER INCLUDING WALLS AND TOP AND ELEVATIONS,SECTIONS,DETAILS OF INSTALLATION AND CONNECTIONS,AND MATERIAL SPECIFICATIONS,UNLESS OTHERWISE BOTTOM OF SLABS 1" NOTED. 12. WELDING OF REINFORCING BARS IS PROHIBITED WITHOUT PRIOR WRITTEN APPROVAL FROM THE ENGINEER.IF WELDING OF 2. SHOP DRAWINGS AND OTHER ITEMS SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO REINFORCING IS NECESSARY,IT SHALL BE PERFORMED IN ACCORDANCE WITH AWS D1.4.REINFORCING STEEL FOR WELDED FABRICATION. BEFORE BEING SUBMITTED FOR REVIEW,ALL SHOP DRAWINGS SHALL BE CHECKED BY THE FABRICATOR AND ASSEMBLIES SHALL CONFORM TO ASTM A706 SPECIFICATIONS. A M E RC BEAR THE CHECKER'S INITIALS AND SHALL BE REVIEWED BY THE CONTRACTOR FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS AND HAVE AN APPROVAL STAMP PLACED ON EACH SHOP DRAWING INDICATING SUCH. ANY SHOP DRAWING NOT 13. SPLICED BARS SHALL HAVE A MINIMUM LAP OF CLASS B TENSION LAP SPLICE PER TYPICAL DETAILS. RFAT"F'STgTE COMPANY CHECKED OR REVIEWED BY THE FABRICATOR AND CONTRACTOR PRIOR TO BEING SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW MAY BE REJECTED AND RETURNED WITHOUT REVIEW. 14. GALVANIZED REINFORCING SHALL BE TREATED TO PREVENT REDUCTION OF BOND. OTHERWISE PROVIDE SPLICE LENGTHES CONSTRUCTION DEPARTMENT EQUIVILANT TO EPDXY COATED REINFORCING. 2727 NORTH CENTRAL AVENUE 3. IN NO CASE SHALL REPRODUCTION OF THE CONTRACT DRAWINGS BE USED AS SHOP DRAWINGS. fPHOENIX, ARIZONA 85004 15. ALL REINFORCING STEEL INDICATED AS BEING CONTINUOUS(CONT.)ON THE PLANS AND DETAILS SHALL BE LAPPED WITH A 4. DESIGN AND DETAILING SHALL BE PERFORMED USING RATIONAL ENGINEERING DESIGN PRACTICES AND BE BASED ON i CLASS B SPLICE OR 36x BAR DIAMETER(WHICHEVER IS GREATER)UNLESS OTHERWISE NOTED. P: (602) 263-6502 STANDARD PRACTICES IN ACCORDANCE WITH CONSTRUCTION DOCUMENTS AND THE BUILDING CODE AND ALL APPLICABLE F: (602) 277-1026 BUILDING CODE AMENDMENTS. 16. REINFORCING BARS TO EXTEND 12 BAR DIAMETERS BUT NOT LESS THAN 12"BEYOND BAR BENDS,UNLESS OTHERWISE NOTED. SITE ADDRESS: 5. THE ENGINEER'S REVIEW IS TO VERIFY CONFORMANCE WITH DESIGN CONCEPT AND GENERAL COMPLIANCE WITH THE PERTINENT CONTRACT DOCUMENTS.THE ENGINEERS REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY 17. PROVIDE ADDITIONAL BARS AS SHOWN IN TYPICAL DETAILS. N ORDINATE THE SHOP DRAWINGS PRIOR TO SUBMISSION.THE CONTRACTOR REMAINS SOLELY Z U-Haul Moving Storage TO REVIEW,CHECK,AND CO < of Hyannis RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, 1 8. ALL REINFORCING STEEL SHALL BE SET AND TIED IN PLACE PRIOR TO POURING OF CONCRETE.NO BARS PARTIALLY 594 Bearses Wa DETAILS,DIMENSIONS,ETC. EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE Y ENGINEER IN WRITING. p Hyannis MA 02601C) 6. AS A MINIMUM,SUBMIT THE FOLLOWING ITEMS FOR REVIEW: 19. PROVIDE CORROSION RESISTANT ACCESSORIES SUCH AS PLASTIC COATED(NOT PLASTIC TIPPED)OR STAINLESS STEEL Li SHEET _CONTENTS: a. REINFORCING STEEL IN REINFORCED CONCRETE AND MASONRY CONSTRUCTION-INCLUDE DETAILS OF ALL BENT BARS, CHAIRS IN ALL EXPOSED CONCRETE CONSTRUCTION.PRECAST CONCRETE CHAIRS OR SAND PLATE CHAIRS SHALL BE USED VERTICAL REINFORCING AND HORIZONTAL BOND BEAM REINFORCING.INCLUDE PLANS AND ELEVATIONS AS REQUIRED TO FOR THE SUPPORT OF REINFORCING ON GRADE.CONCRETE BLOCK OR CLAY MASONRY BRICK ARE NOT PERMITTED. Q General Structural Notes CLEARLY SHOW ALL REINFORCING. W for Steel Shade Canopy 20. ALL EXPOSED CORNERS OF CONCRETE TO HAVE 3/4"MINIMUM CHAMFER UNLESS OTHERWISE NOTED. b. ALL CONCRETE CONSTRUCTION-SUBMIT A CONCRETE MIX DESIGN FOR EACH CONCRETE STRENGTH. AS A MINIMUM, EACH DESIGN SHALL INCLUDE PROPORTIONS OF CEMENT,FINE AND COURSE AGGREGATES,AND WATER,GRADATION OF 21, CONCRETE SHALL BE DISCHARGED AT THE SITE WITHIN 1-1/2 HOURS AFTER WATER HAS BEEN ADDED TO THE CEMENT AND Lij Q COMBINED AGGREGATES,AND CONCRETE COMPRESSIVE TEST RESULTS. CERTIFICATION SHALL BE FROM AN AGGREGATE, ADDITION OF WATER TO THE MIX AT THE PROJECT SITE IS STRICTLY PROHIBITED. ALL WATER MUST BE ADDED ACCEPTABLE TESTING LABORATORY. AT THE BATCH PLANT ONLY. Q 796054 c. STRUCTURAL STEEL-IF STEEL CANOPY IS NOT PROVIDED BY U-HAUL,SUBMIT SHOP DRAWINGS AND CALCULATIONS 22. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CONCRETE OPENINGS AND/OR PENETRATIONS REQUIRED tY SIGNED AND SEALED(CALCULATIONS ONLY)BY A QUALIFIED PROFESSIONAL ENGINEER.CALCULATIONS SHALL INCLUDE AS FOR OTHER TRADES PRIOR TO PLACING CONCRETE. LEI A MINIMUM,ALL LOADS,STRESSES,AND DEFLECTIONS ASSOCIATED WITH EACH MEMBER AND/OR CONNECTION. DRAWN: JRG Q vi 23. SEE ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND PLUMBING DRAWINGS FOR REGLETS,PIPE SLEEVES,CONDUITS OR - I OTHER ITEMS TO BE EMBEDDED OR PASSED THROUGH CONCRETE. AUN U , CV CHECKED: AML 1N o DATE: 10.14.13 Q 796054-FABRIC CANOPY "S_2013-10-14.dwg f i i GENERAL NOTES: 7 10'-0" S3.1 TYP 20'-0" 10'-0" 7 ;ic- ` & n l£ 6 KNITTEX®COLOURSHADE'RAINFOREST'OR S3.1 TYP 'ROYAL BLUE'CANOPY OR EQUAL APPROVED BY U-HAUL CONSTRUCTION DEPARTMENT. 49-0" C 5 S3.1 TYP REVISIONS: i.Y _�i t—�i t l r( II 8 II l[ (i I T1 t—i i I—i I t i r i—I I�—i i�—r n—i i�—i 7�i I i=���=I i►-i i I=i i i=i I I=�i t I i t—III—�(i—i I i—I f 1—i(1—i I I t i i—i i i—i�i—i�7--i"i'�i i i=i i i'=i i'i=i r i-i i 1-�i i-i!�={! II II II -11(=t I t—i i 1 I=1 I I—!i I: -i I I III LIJ III I=1I J— M-- 4 —III I I li 11 —I l III !!�11 I1f1I1Ey 3 20'x40' STEEL CANOPY SIDE ELEVATION SCALE: 1/4" = T-e" 40'-Y' 20'-0" ~ � Q Ck t f I f E } � i a •-a, a .. s. ,. •: z ,=e .y .�,,... a ..,.r t, ;x ;. ;.. r.,. n a�i ,✓», �ii � k l Lr o Li1 . : �. <.. :,..:�.. 1.. ... .,,.. a . , .. .. s C�JCo „„,,.-. $ ? �� ;,,.k . al .�„ .e.S�" ..,.t�, i '; LLJ xk.'kh ..;:: a5 6 �,a :-Em ¢ a-,,. , 1 � :� ,v PROFESSIONAL SEAL: .�... ... ... .... ,.. �....+. .. ,.. .. ..e.,n .. .. .... ...... to .,. �.. ...,s , t r� r ...., co I 0 y �£'' � 5 x �a�' � z{€"��',r a��`�.,s .,, `.k°.•'. ,.., .:.:;;. ., t sa� I a ea«,.�Q r e—^' .� � N , I" Lu p ,1 £ ,., e' ,. Lj co f � . HSS.6x4x1l4 0R s .:., 3'r £ �--- a' APPROVED AlP.<< OVED EQU TY a .�._� r.. � .. ,, � ., ti. , . /'^'� ., E'i 1 a, I CO ryry ''''''mo�ww 'S-- : .0 � :..+... h ..z...; .x ,..: ,..✓,.:;: ersbv._,.:.,, m uT .5.:_: .nf,,u.,, :..' ,:�.m ..t Y� �u.�4. CD „ , ,: ,_,.., ,., r . :GALI�ANI ED HSS 4.60W.331 OR ,� ��;- Z ��' z r i �.,,, . O �.F 71 �„ �. , -a 77, �KNITTEX®`CO- LOURS` ;4 � ROYAL. 41 `SL�1�E; a �i CANOPY ORQUAL .(APPROVED BY JL �. k ARCHITECT LOGO: DEPARTMENT. 2 20'x40' STEEL CANOPY PLAN SCALE: 1/4" = V-0" KNITTEX®COLOURSHADE'RAINFOREST OR 'ROYAL BLUE'CANOPY OR EQUAL APPROVED BY C r U-HAUL CONSTRUCTION DEPARTMENT. 39'-7" z r , a # a` art f' nit 'sc — — — — — _ — _ _ — _ _ — _ _.�- — — - -�— �— — AMERCOo �F.SMk1 ii W1YltL]l�l 1 CONSTRUCTION DEPARTMENT 6 I 2727 NORTH CENTRAL AVENUE S3.1 TYP PHOENIX, ARIZONA 85004L GALVANIZED HSS 5.000x0.375 OR I ( P: (602) 263-6502 APPROVED EQUAL,TYP, F: (602) 277-1026 20'-0" SITE ADDRESS: z U-Haul Moving & Storage Q of Hyannis f :E `594 Bearses Way 0 Hyannis, MA 02601 U 5 I w SHEET CONTENTS: S3.1 TYP r d Plans and Elevations �n for 20'x40' Steel Shade Canopy Jf ��—i n— rT— r�— ��—Yrr—�,i' 'ri i—�s r—,��—,-�•i-'i f I"='1"i`i-1 i Y'.'.i`i`i"``�r u ��i=��� i'it ��� a�'t`'�'. i rr ,i, ��i�'i`= � ( TYP W S3.1 - 11= L0J I1= I III LOJ Ill_ 0 796054 I III I —I I_� ---T � r � DRAWN: JRG l _I i i=i FEE 11= I ICI i= —I / / CHECKED: AML o DATE: 10.14.13 1201X401 STEEL CANOPY SIDE ELEVATION ° - r, 1 20x40' STEEL CANOPY FOUNDATION PLAN ° - SCALE: 1/4 - 1 0 SCALE: 1/4 — 1 0 © 796054_FA13RrC CANOPY PLANS_2013-10-14.Qwg GENERAL NOTES: \ 3/8"STIFFENER PL TYP }-- /// HSS HIP PER PLANS I 'I REINFORCING DEVELOPMENT LENGTH OF STANDARD HOOKS TABLE-TYPICAL U.N.O. BAR CONCRETE MASONRY TYP� 2A" SIZE ALL ALL i #3 9 5 i #4 11 6 STEEL ROD 1/2"DIA X 13/4"LONG #5 14 s #6 17 9 � #7 20 10 ® #8 22 12 #9 25 - COLUMN CAP.HSS 5.5004.188 X 6" N #10 28 - LONG W/3/8"X 51/2"DIA.STEEL (2)5/8"DIA A325 BOLT W/ #11 31 - CAP PL NUT WELDED TO ONE SIDE OF HIP #�e - N TABLE NOTES: TYP 1. DEVELOPMENT LENGTHS ARE CALCULATED PER ACI 318-05,12.2.3,EQ.(12-1)FOR CONCRETE AND ACI 530-05.2.1.10.5.1 FOR MASONRY. (2)1/2"DIA A325 THRU BOLT W/ 2. DEVELOPMENT LENGTH SHALL BE INCREASED BY 30% WASHER AND NUT FOR LIGHTWEIGHT CONCRETE. i STEEL COLUMN PER PLANS 'I 6C 20'x4O' STEEL CANOPY COLUMN CAP DETAIL 3/4" V-0" 4 REINF. DVLPMNT STANDARD HOOKS TABLE NOSCALE: REVISIONS: 6 ELEVATION PLAN RECOMMENDED END HOOKS(ALL GRADES)D=FINISHED DETAILING DIMENSION HOOK BEND DIAMETER A or G (BOTTOM) BAR 180"HOOKS 9('HOOKS 3/8"SS Or GS SIZES D(in.) A or G J A or G CABLE U.N.O. #3 2114 5 3 6 � -•� D CONCRETE FOUNDATION #a 3 6 4 8 CL COUM,& BEYOND #5 33/4 7 5 10 4d,21/2 MIN. FTG #6 41/2 8 6 1-0 180° #7 51/4 10 7 1-2 180` #8 6 11 8 1-4 TYP I TYP #9 9 1-3 113/4 1-7 go, #10 101/4 1-5 1-03A 1-10 #11 111/4 1-7 1-2314 2-0 Or #14 17 2-3 1-81/2 2-7 o 2 D \ #18 22 3/4 3-0 2-3 314 3-5 o-1/B. I b -o CABLE U.N.O. a `� 0 0 3/8"ROD so" STEEL COLUMN PER PLANS 1 SEISMIC STIRRUP/TIE HOOK DIMENSIONS(ALL GRADES) BAR 135'HOOKS 90°HOOKS SIZES D(in.) A or G H APPROX. A or G Y 6 135' TYP 1l2"THICK x 12"DIA.STEEL #3 1 1/2 41/4 3 4 3/16" I BASE PL #4 2 41/2 3 41/2 #5 21/2 51/2 33/4 6 w #6 41/2 8 41/2 8 ti = 0 NOTE: 1 #7 51/4 9 5114 1 9 Z z TENSION HIP COMPRESSION CABLE USING 3/8" #s s 101n s 10 � N LU TURNBUCKLE OR SIMILAR.TENSION TO I ALL SPECIFIC SIZES RECOMMENDED BY CRSI BELOW MEET MINIMUM REMOVE CABLE SLACK TO TAUGHT CONDITION. REQUIREMENTS of ACI 318 0 d Z DO NOT DEFLECT HIP MEMBERS DUE TO EXCESSIVE TENSION. I a (6)3/4"DIA ANCHOR RODS 0 135` ¢ I I I I I I I I STEEL COLUMN PER PLANS 1 EQUALLY SPACED(16"MIN SCALE: EMBED INTO FOOTING). SCALE: 9C HIP COMPRESSION CABLE 3/411 11-011 1/2"STEEL GUSSET PL STEEL BASE PL 3 REINFORCING STANDARD HOOKS NO SCALE z N 1 PROFESSIONAL SEAL: i 1 1/2"NON BRINK GROUT OR 1 I N HARDSCAPE OR FINISH GRADE 1/4"NON-SHINK GROUT W/1/4" AS OCCURS. LEVELING PL = c 5 ��1i OF F,, £ _� r +1' \ RIDGE AND HIP SLEEVE.HSS $ N w v � ' 4.500x0.188 X 24"LONG { I ( { { { { dl I a { { { { I I I �. vC„ v Il q EI J 1 0 :2- \\� 1/2"STIFFENER PL BEYOND(ONE w -00 _ c � ° + O No•�5�333 J \\\\ AT RIDGE AND EACH HIP) 0 _ c I I I I IIl- LAP-SPLICE LENGTH FOR UNCOATED REINFORCING BARS �I CQT> L!J -14 HSS HIP PER PLANS I + - LJJ c0 1- - 6 \\\\ c� - I LENGTHS(IN.) '��I -0 �+""gt����+r0��'4! \\\ HSS RIDGE PER PLANS ° aaJ I SINGLE MAT DOUBLE MAT c,` 0 t� �- \\\ Z a�Q n .Q — BARSIZE 1500 PSI 1800 PSI 2000 PSI 1500 PSI 1800 PSI 2000 PSI I y r 1 LL. { II III= 0 to c � \\ #4 25 23 22 3t 29 27 -j CONCRETE PIER.REINFORCE W/ (8)#5 VERT BARS EQUALLY #5 31 29 21 as 45 42 c w #6 53 48 46 1 98 90 85 SPACED AND#3 TIES @ 6"O.C. #7 67 st 1 58 133 122 116 o VERTICALLY.PROVIDE DOUBLE r #8 93 a5 a1 tas 170 1s1 ARCHITECT LOGO: 2'-0"TYP a . TIES AT TOP OF PIER.ALL TIES TO #9 119 108 103 237 216 205 "' ENCOMPASS VERTICAL REINF AND — ANCHOR RODS AND BE TIED TO NOTES: 1. LAP-SPLICE LENGTHS ARE CALCULATED PER 2006 IBC 2107.5. a v a VERTICAL REINF. 2. TABULATED VALUES ARE BASED ON GRADE 60 REINFORCING BARS. 3. FOR GRADE 40 REINFORCING BARS MULTIPLY TABULATED VALUES BY 0.67(15-LAP MIN). 4. MECHANICAL SPLICE REQUIRED FOR BAR SIZES GREATER THAN#9. (MECHANICAL SPLICES SHALL DEVELOP 125%OF THE TENSILE STRENGTH OF THE BAR) 3 aR. J TYP 2,-0" 8C 20'x40' STEEL CANOPY HIP/RIDGE DETAIL 3/4" =>- V-0" 5C 20LE: 'x40' STEEL CANOPY FOUNDATION DETAIL 3/411 11-011 2 LAP SPLICE SCHEDULE FOR MASONRY REINFORCING BARS NOSCALLE AMERCOo Detail Notes: �,FSrMT co�� 1. TABULATED VALUES ARE BASED ON GRADE 60 REINFORCING BARS AND NORMAL WEIGHT CONSTRUCTION DEPARTMENT CONC. 2727 NORTH CENTRAL AVENUE PHOENIX, ARIZONA 85004 3/8"STEEL PL.CUT TO FORM 2. TENSION LAP-SPLICE LENGTHS ARE CALCULATED PER ACI 318,SECTIONS 12.15. TABULATED RIDGE AND HIP SLEEVE.HSS 1/2"STIFFENER PL(ONE AT RIDGE LAP SPLICE LENGTHS (IN.) VALUES FOR BEAMS OR COLUMNS ARE BASED ON TRANSVERSE REINFORCEMENT AND P: (602) 263-6502 --- 4.500x0.188 X 24"LONG AND EACH HIP) CONCRETE COVER MEETING MIN.CODE REQUIREMENTS. F: (602) 277-1026 - -- 2�-�" LENGTHS IN.) (2)1/2"DIA A325 BOLT W/ HSS RIDGE PER PLANS BAR LAP� 2500 00 PSI 3000 PSI 35M PSI 4000 PSI 4500 PSI 5000 PSI 3. CASES 1 AND 2,WHICH DEPEND ON THE TYPE OF STRUCTURAL ELEMENT,CONCRETE SITE ADDRESS:� NUT WELDED TO SLEEVE SIZE CLASS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS CASE 1 CASE 2 CASE 1 CASE z CASE 1 CASE 2 CASE 1 CASE 2 CASE 1 CASE 2 CASE 1 ICASE 2 CASE 1 CASE 2 CASE 1 CASE 2 CASE 1 ICASE 2 CASE 1 CASE 2 CASE 1 CASE 2 CASE 1 CASE 2 COVER,AND CENTER-TO-CENTER SPACING OF THE BARS ARE DEFINED AS: TYP U-Haul Moving & Storage #3 A 24 36 18 27 22 33 17 25 20 30 16 1 23 19 28 15 22 18 27 14 21 17 25 13 1 20 BEAM OR COLUMNS: z HSS HIP PER PLANS MAN' B 31 4 44 36 28 42 22 33 26 39 20 30 25 37 19 28 23 35 18 27 22 33 17 25 CASE 1-COVER AT LEAST 1.0 db AND CENTER-TO-CENTER SPACING AT LEAST 2.0 db Q of Hyannis A 32 47 24 36 29 43 22 33 27 40 21 31 25 37 19 29 24 35 18 27 23 34 17 26 CASE 2-COVER LESS THAN 1.Odb OR CENTER-TO-CENTER SPACING LESS THAN 2.0 D- 594 Bearses Way E�N B 41 61 32 47 38 56 29 43 35 52 27 40 33 49 25 37 31 46 24 35 29 44 23 34 i A 39 59 30 9 36 54 2842 33 50 26 39 31 47 24 36 30 44 23 34 28 42 22 32 db. Hyannis, 02681 #5 B 51 77 39 59 1 47 70 1 36 1 54 43 1 65 33 50 41 61 31 1 47 38 57 30 44 1 36 54 28 42 ALL OTHERS: 0 #6 A 47 71 36 54 43 65 1 33 50 40 1 60 31 46 37 56 29 43 35 53 27 41 34 50 26 39 CASE 1-COVER AT LEAST 1.0 db AND CENTER-TO-CENTER SPACING AT LEAST 3.Odb. SHEET CONTENTS: B 61 92 47 71 56 84 43 65 52 78 40 60 49 73 37 56 46 69 35 53 44 65 34 50 Ly J �--, �" P a n CASE 2-COVER LESS THAN 1.0 db OR CENTER-TO-CENTER SPACING LESS THAN 3.0 A 69 103 53 79 63 94 48 72 58 87 45 67 54 81 42 63 51 17 40 59 49 73 38 56 F- 9"� #7 B 89 134 69 103 81 122 63 94 75 113 58 87 71 106 54 81 67 100 51 77 63 95 49 73 db Q Structural Details ih v A 78 117 60 90 72 107 55 83 66 99 51 77 62 93 48 72 59 88 45 68 56 83 43 64 ~ #a cn for Steel Shade Canopy „T(P B toe 153 78 1n 93 139 72 107 as 129 ss ss 81 121 s2 s3 7s 11a 5s 88 72 1os 5s 83 4. ACI 318 DOES NOT ALLOW LAP SPLICES OF#14 OR#18 BARS. THE TABULATED VALUES FOR L LI p112 TYP #9 A 88 132 68 102 81 121 62 93 75 112 58 86 70 105 54 81 66 99 51 76 63 94 48 72 THOSE BAR SIZES ARE THE TENSION DEVELOPMENT LENGTHS. B 115 172 88 132 105 157 81 121 97 146 75 112 91 136 70 105 86 128 66 99 81 122 63 94 1 A 100 149 77 115 91 136 70 105 84 126 65 97 79 118 61 91 74 111 57 86 71 106 54 81 LQ #10 B 129 194 100 149 118 177 91 136 109 164 84 126 102 153 79 11s ss 144 7a 111 s2 137 71 106 5. TOP BARS ARE HORIZ.BARS WITH MORE THAN 12 IN.OF CONCRETE CAST BELOW THE BARS. #11 A 110 165 85 127 101 151 78 116 93 140 72 108 87 131 67 101 82 123 64 95 79 117 60 90 B 143 215 110 165 131 196 101 151 121 182 93 140 114 n0 a7 131 107 160 82 123 10z 152 78 117 6. FOR GRADE 40 REINFORCING BARS,MULTIPLY TABULATED VALUES BY 0.67 12"LAP MIN.).#14 N/A 133 199 102 153 121 181 93 140 112 168 86 129 105 157 81 121 99 148 76 114 94 141 72 108 ( ) O 796054 - #18 wA 177 265 136 204 161 242 124 186 149 224 115 n2 1ao 209 1oa 1s1 132 ts7 101 1s2 12s ts7 96 144 FOR LIGHT WEIGHT CONC.,MULTIPLY TABULATED VALUES BY 1.3. U 0 4J DRAWN: JRG N CHECKED: AMLS3,1 C SCALE: o DATE: 10.14.13 7C 20'x40' STEEL CANOPY HIP DETAIL 3/41iJCA�o;, 1 LAP SPLICE SCHEDULE FOR UNCOATED CONCRETE REINFORCING BARS NO SCALE © 796054_FABRIC CANOPY PLANS_2013-10-14.dwg I