HomeMy WebLinkAbout1047 FALMOUTH ROAD/RTE 28 (14) ',
j,
�� - - ----
-,.
��. �,.�. _ _. -- 21 B Street
Burlington, MA 01803
C p.N S U L T I N G Tel: (781) 273.2500
www.ebiconsulting.com Fax: (781) 273.3311
Town of Barnstable November 22, 2011
Building Division —�
Thomas Perry
200 Main Street
Hyannis, MA 02601
Re: Construction Control Affidavit
Wireless Telecommunication Tower Modifications
1047 Falmouth Road ��
Barnstable, MA 02601
Dear Mr. Perry:
This letter is to affirm that all plans, computations and specifications involved in.the
modification of the above mentioned wireless telecommunication tower shall be prepared by
or under the direct supervision of a registered design professional and shall bear his signature
and seal. Said signature and seal shall signify that the plans, computations and specifications
meet the applicable provisions of the Massachusetts Building Code and accepted engineering
practices. The structural design of the wireless communication tower shall also be reviewed
and computations performed by a registered structural engineer to verify that the
modifications in no way affect the structural integrity of the structure.
As part of the construction process,the registered design professional responsible for the
design, plans, calculations and specifications, or his designee, will perform the following tasks
as part of the construction process.
1. Review for conformance with the construction documents the shop drawings, samples
and other submittals by the contractor.
2. Be present at appropriate intervals to insure the quality of the work and to determine if
the work is being performed in a manner consistent with the construction documents
and code.
R.
po com do f th s mit a letter as to the satisfactory completion and
're,adi ess of h r j
rn
v 9�y
\ 4729T
� .. .
RTY
Daniel V. Doherty, P.
S� NAL
Subscribed and sworn to be a this day of Ad n �
9//41/ IS
otary Public My Co mi sion Expires .a
i
ENVIROBUSINESS,INC.LOCATIONS I ATLANTA,GA I BALTIMORE,MD I BURLINGTON,MA I CHICAGO,IL
DALLAS,TX I DENVER.CO I HOUSTON,TX I LOS ANGELES,CA I NEW YORK,NY I PHOENIX,AZ I PORTLAND,OR
SAN FRANCISCO,CA I SEATTLE,WA I YORK,PA
BABNBIABLL
MABB.
�PrED MPS�
Town of Barnstable
Zoning Board of Appeals
Agenda
May 21, 2008
Revised as of 05-14-08
7:00 PM Appeal 2008-028 Childs
Modification Variance No. 2000-024 & 1975-093
This appeal has requested a withdrawal without prejudice as it was incorrectly noticed under the name
of Randall E. Childs when it should have been noticed under RELD Corporation. A new application
has been submitted and is scheduled for the June 11 hearing. April 28, 2008 letter from Attorney
Bruce P. Gilmore is enclosed.
Randall E. Childs has applied for a Modification of Variance No. 2000-024 and 1975-093. The modification
bseeks to change Condition No. 1 of Variance 2000-024 that now restricts the number of office suites to four.
The modification seeks to allow for six office suites in the existing building. The property is addressed as
,�1047 Falmouth Road (Route 28)., Hyannis,.MA and'is shown on Assessor's Map 250 as parcel 004. The
property is i a Residence D-1 Zoning District.
7:00 PM Appeal 2008-008 - Continued Oyster Harbor Club
Expand/Alter Nonconforming Use
Opened February 27, 2008, continued, March 12, 2008, April 30, 2008, and to May 21, 2008
Continued for Attorney Town Attorney's Office input into the issue of building a new additional
building (for an accessory use) on a lot upon which an existing preexisting nonconforming use exists.
Request letter of May 2, 2008, and follow-up clarification letter of May 8, 2008 are enclosed. A copy
of Attorney Edward W. Kirk May 14, 2008 correspondence to Tow Attorney Ruth Weil is enclosed.
Town Attorney, Ruth Weil communicated to staff that her office will need additional time to review and
communicate to the Board on this issue. Staff has communicated this to Attorneys Kirk and Murphy
and staff anticipates they will be requesting a continuance of this appeal to the June 11` or July 9`h.
meeting of the Board.
Members: Ron S.Jansson,James Hatfield,John T. Norman,Jeremy Gilmore, Gail C. Nightingale
No Alternates
Oyster Harbors Club, Inc. has petitioned for Special Permits pursuant to Section 240-93.13 Alteration and
Expansion of a Nonconforming Buildings or Structures Not Used as Single or Two-Family Dwellings; and
Section 240-94.13 Expansion of a Preexisting Nonconforming Use. The petitioner seeks to remodel an
existing 573 sq.ft., children's play center and to add another accessory building consisting of 1,096 sq.ft., to
also be used as a children's play center. The buildings and use is accessory to the principal nonconforming
use of the property as a Club House. The subject property is located as shown on Assessor's Map 053 as
Parcel 012 Lot 001, addressed as 170 Grand Island Drive Osterville MA 02655, in a Residence F-1 Zoning
District.
r
OWCrown Castle Tel: 704 405.6600
rE 3530 Toringdon way,Suite 300
' Charlotte,NC 28277 www.crowncastle.com
Tuesday June 2,2009
RE: Crown Castle USA Inc..Letter of Authorization(LOA)
Crown Castle USA Inc.., does hereby authorize MetroPCS and its authorized contractors/agents to act as"Applicant" in
the processing of all applications, permits, research and other related activities associated with the processing, planning,
design review, permitting, entitlement and construction of additional equipment, antennas and site improvements.for the
Crown Castle USA Inc., existing wireless communications facility described as follows:
Customer Site HYN0016 Crown Castle Site ID Number: BU#875052
Name:
Site Address: 1047 Falmouth Rd Crown Site
Hyannis,MA Name: Associated Alarm System
This authorization is fully contingent upon MetroPCS and MetroPCS's auhorized contractors/agents'compliance with the
following conditions:
1. Crown Castle USA Inc., must review the application prior to submittal. Crown Castle USA Inc., must be
provided all applications, narratives, drawings and attachments at least 72 hours in advance of their submittal to
the locality. Use of email and electronic attachments is encouraged. A Crown Castle USA Inc.. Zoning Subject
Matter Expert (SME) will review and provide written comment to the customer within 48 hours of receipt of a
complete set of application materials. If Crown Castle USA Inc.. indicates that changes are required,
submissions shall be altered in accordance with Crown Castle USA Inc., comments prior to submission to the
locality. Verification of corrections should also be accomplished via emails and attachments.
2. In no event may MetroPCS encourage, suggest, participate in, or permit the imposition of any restrictions or
additional obligations whatsoever on the tower site or Crown Castle USA Inc., current or future use or ability to
license space at the tower site as part of or in exchange for obtaining any approval,permit,exception or variance.
3. A copy of the final permit and/or a written summary of the zoning/entitlement decision rendered by the locality and
any/all conditions placed on that decision shall be communicated in detail to Crown Castle USA Inc.. well within
the appeal period provided by the locality(typically 10-15 days).
4. All conditions of approval pertinent to the construction of the proposed project must be included in the
construction drawings for the project. The conditions of approval pertinent to the construction of the project shall,
be copied verbatim from the zoning permit approval language, and shall be present in the:drawings-prior to.
submission for building permits and contractor bidding. Crown Castle USA Inc., shall verify the inclusion of
appropriate conditions of approval in the construction drawing redline process.
5. Crown Castle USA Inc., will provide a Notice To Proceed(NTP)to construction to the customer upon receipt of
the final approved zoning permit and the approved Building Permit.
Crown.Castle US&Inc..
Signature:
Printed Name: Paul Hughey
Title: Property Specialist
704`405-6571
The Commonwealth of Massachusetts
Department of Public Safety
One Ashburton Place, Room 1301
Boston, Massachusetts 02108-1618
Phone (617) 727-3200
Fax (617) 727-5732
CONSTRUCTION CONTROL DOCUMENT
Project Title: HYN00I6A (Crown Hyannis 875052) Date: Dec 10,2009
Project Location: 1047 Falmouth Road,Hyannis,MA 02601
Scope of Project: Installation of telecommunication antennas and cables on existing monopole,and installation of wireless ground
equipment.
In accordance with SECTION 116.0-116.4.2 of the 6th edition of the Massachusetts State Building Code,I,Marc R.Chretien,Mass.
Registration Number 40313 being a registered professional Engineer/Architect hereby CERTIFY that I have prepared or directly
supervised the preparation of all design plans,computations and specifications concerning:
[X] Entire Project [ ] Architectural [ ] Structural [ ] Mechanical
[ ] Fire Protection [ ] Electrical [ ] Other(specify)
for the above named project and that to the best of my knowledge,such plans,computations and specifications meet the applicable
provisions of the Massachusetts State Building Code,all acceptable engineering practices and all applicable laws for the proposed
proj ect.
Furthermore,I understand and agree that I shall perform the necessary professional services and be present on the construction site on
a regular and periodic basis to determine that the work is proceeding in accordance with the documents approved by the building
permit and shall be responsible for the following as specified in section 116.2.2:**
1. Review of shop drawings,samples and other submittals of the contractor as required by the construction contract documents as
submitted for the building permit,and approval for the conformance to the design concept.
t
2. Review and approval of the quality control procedures for all code-required controlled materials.
3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the
work and to determine, in general, if the work is being performed in a manner consistent with the construction documents.**
**Requires timely notification of construction commencement by the contractor of record and timely notification(min.of 48 hours)of
critical construction milestones by the contractor of record. If not notified by the contractor of record of these events,this office
assumes no responsibility for the construction of the project.
I shall submit periodically,in a form acceptable to the building official,a progress report together with pertinent comments. Upon
completion of the work,I shall submit to the building official a final report as to the satisfactory completion and readiness of the
project for occupancy.
OF Mg9
Signature and Seal of registered professional: yk� n
MARC
R.
o CHRETIEN —+
CIVIL
N 0.40313
THE Barnstable
�
■ All-MMca City
* &MMSTABLE,
39. The Town of Barnstable Q P
Growth Management Department
Jo Anne Miller Buntich 2007
Interim Director
July 31, 2009
Metro PCS Massachusetts, LLC
do J. Lee Consulting, Inc.
Gerry Squires, Agent/Site Acquisition Consultant
101 Palisades Circle
Stoughton, MA 02017
RE: Site Plan Review # 019-09 2� � "� OoLf
1047 Falmouth Road, Hyannis -Wireless Communications Facility- Addition
of 3 antennas and.related ground equipment to an existing monopole.
Dear Mr. Squires:
Please be advised that the above referenced proposal was found to be
administratively approvable subject to the following:
• Approval is based upon Site Plan Review package dated June 22, 2009
which included plans entitled, "NYN0016A, Crown 875052, Hyannis, Site
Address 1047 Falmouth Road, Hyannis, MA" 8 sheets: T-1, C-1, S-1 & 2, E-1
& 2 all dated 6/11/09, prepared by Advanced Engineering Group, P.C.,RI,
stamped Marc R. Chretien, PE Mass., prepared for Metro PCS, Chelmsford,
MA said plans depict site:plan, elevations, equipment details, antenna details
& electrical details.
• Applicant must obtain and comply with all other applicable permits, licenses and approvals required.
• Approval of a modification of an existing variance must be obtained from the
Zoning Board of Appeals:
367 Main Street, Hyannis, MA 02601 (o) 508-862-4678 (f) 508-862-4782
200 Main Street, Hyannis, MA 02601 (o) 508-862-4786 (f) 508-862-4784
• Upon completion of all work, a registered engineer or land surveyor shall
submit a letter of certification, made upon knowledge and belief in
accordance with professional standards that all work has been done in
substantial compliance with the approved site plan and any changes
resulting from Zoning Board of Appeals decision. Zoning Section 240-104
(G). This document shall be submitted prior to the issuance of the final
certificate of occupancy.
Sincerely,
Ellen M. Swiniarski
Site Plan Review/Regulatory Review Coordinator
200 Main Street, Hyannis
508-862-4679
CC: SPR File # 019-09
Building Commissioner, Tom Perry
Zoning Board of Appeals
367 Main Street, Hyannis, MA 02601 (o) 508-862-4678 (f) 508-862-4782
200 Main Street, Hyannis, MA 02601 (o) 508-862-4786 (f) 508-862-4784
Page 1 of 1
Gerry Squires
From: Lt Don Chase[dchase@hyannisfire.org]
Sent: Friday, December 18, 2009 11:36 AM
To: Gerry Squires
Subject: RE: MetroPCS installation @ 1047 Falmouth Rd
Hi,
All set with the building dept. I sent them an email (Sally)to let them know we had no issues there. One
question, how is the generator fueled?Thanks
Don
Lt. Don Chase, FPO
Fire Prevention Officer
Hyannis Fire Department
508-775-1300
(c) 508-648-5806
From: Gerry Squires [mailto:GSquires@jleeconsulting.net]
Sent: Thursday, December 17, 2009 12:01 PM
To: dchase@hyannisfire.org
Subject: MetroPCS installation @ 1047 Falmouth Rd
Don,
Per our conversation I have attached a set of plans for your review. I appreciate your help wit this.
My email is gss uires ieeconsulting.net.
Please call me at 781-363-6334 if you have any questions..
Thank you,
Gerry Squires
No virus found in this incoming message.
Checked by AVG-www.avg.com
Version: 9.0.716/Virus Database: 270.14.113/2573-Release Date: 12/18/09 02:35:00
No virus found in this incoming message.
Checked by AVG-www.avg.com
Version: 8.5.427/Virus Database: 270.14.112/2571 -Release Date: 12/18/09 07:35:00
I
12/21/2009
- Barnstable
�FWI
Tp�
�O
A TOINN OF BARN TABLE
All-America City
BUMMBLE,
v Mnss. �
�AEo. The TO n -q B astable
r A 2 L a r-1
Growth Management apartment
Jo Anne Miller Buntich 2007
Interim Director `- -`_ •' ..
July 31, 2009
Metro PCS Massachusetets, LLC
c/o J. Lee Consulting, Inc.
Gerry Squires, Agend/Site Acquisition Consultant
101 Palisades Circle
Stoughton, MA 02017
RE: Site Plan Review # 019-09 Q
1047 Falmouth Road, Hyannis - Wireless Communications Facility - Additions!'
of 3 antennas and related ground equipment to an existing monopole.
Dear Mr. Squires:
Please be advised that the above referenced proposal was found to be
administratively approvable subject to the following:
• Approval is based upon Site Plan Review package dated June 22, 2009
which included plans entitled, "NYN0016A, Crown 875052, Hyannis, Site
Address 10-47 Falmouth Road, Hyannis, MA" 8 sheets: T-1, C-1, S-1 & 2, E-1
& 2 all dated 6/11/09, prepared by Advanced Engineering Group, P.C., RI,
stamped Marc R. Chretien, PE Mass., prepared for metroPCS, Chelmsford,
MA said plans depict site plan, elevations, equipment details, antenna details
& electrical details.
• Applicant must obtain and comply with all other applicable permits, licenses
and approvals required.
• Approval of a modification of an existing variance must be obtained from the
Zoning Board of Appeals.
367 Main Street, Hyannis, MA 02601 (o) 508-862-4678 (f) 508-862-4782
200 Main Street, Hyannis, MA 02601 (o) 508-862-4786 (f) 508-862-4784
• Upon completion of all work, a registered engineer or land surveyor shall
submit a letter of certification, made upon knowledge and belief in
accordance with professional standards that all work has been done in.
substantial compliance with the approved site plan and any changes
resulting from Zoning Board of Appeals decision. Zoning Section 240-104
(G). This document shall be submitted prior to the issuance of the final
certificate of occupancy.
Sincerely,
49a
Ellen M. Swiniarski
Site Plan Review/Regulatory Review Coordinator
200 Main Street, Hyannis
508-862-4679
CC: SPR File # 019-09
Building Commissioner, Tom Perry
Zoning Board of Appeals
367 Main Street, Hyannis, MA 02601 (o) 508-862-4678 (f) 508-862-4782
200 Main Street, Hyannis, MA 02601 (o) 508-862-4786 (f) 508-862-4784
f
Am WTI
Date: May 15,2009 GPD ASSQUATES
Steve Tuttle GPD Associates
Crown Castle USA Inc. 520 South Main Street, Suite 2351
349 West Commercial Street Akron, Ohio 44311
East Rochester, NY 14445 (330)572-2205
(585)899-3445 jbutterfield(a�odoroup.com
Subject: Structural Analysis Report
Carrier Designation: Metro PCS Co-Locate
Carrier Site Number: HYNO016
Crown Castle Designation: Crown Castle BU Number: 875052
Crown Castle Site Name: Associated Alarm System
Crown Castle JDE Job Number: 119787
Crown Castle Work Order Number: 272068
Engineering Firm Designation: GPD Associates Project Number: 2009184.47
Site Data: 1047 Falmouth Rd, Hyannis, MA 02601, Barnstable County
Latitude 41°39'32.184", Longitude-700 19'32.808"
118 Foot—Summit Monopole Tower
Dear Mr. Steve Tuttle,
GPD Associates is pleased to submit this "Structural Analysis Report" to determine the structural integrity of
the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural
`Statement of Work' and the terms of Crown Castle Purchase Order Number 331688, in accordance with
application 73650, revision 2.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
LC1: Existing+ Reserved+ Proposed Equipment Sufficient Capacity
Note:See Table I and Table II for the proposed and existing/reserved loading,respectively.
The analysis has been performed in accordance with the TIA/EIA-222-F standard based upon a wind speed of
100 mph fastest mile.
We at GPD Associates appreciate the opportunity of providing our continuing professional services to you and
Crown Castle USA Inc. If you have any questions or need further assistance on this or any other projects please
give us a call.
Respectfully submitted by: �.�� OF
o� DAM
L" 0CIVIL
G R
4
No. 36965 �
David B.Granger P.E.
Massachusetts#: 36965 +lAt
RISA Tower Report-version 5.3.0.1
T T
Crown Castle USA, Inc. May 15, 2009
118 Ft Monopole Tower Structural Analysis CCI BU No 875052
Project Number 2009184.47,Application 73650, Revision 2 Page 2
TABLE OF CONTENTS
1)INTRODUCTION
2)ANALYSIS CRITERIA
Table 1 -Proposed Antenna and Cable Information
Table 2-Existing and Reserved Antenna and Cable Information
Table 3-Design Antenna and Cable Information
3)ANALYSIS PROCEDURE
Table 4-Documents Provided
3.1)Analysis Method
3.2)Assumptions
4)ANALYSIS RESULTS
Table 5—Section Capacity(Summary)
Table 6-Tower Component Stresses vs. Capacit
y
4.1)Recommendations
5)DISCLAIMER OF WARRANTIES
6)APPENDIX A
RISATower Output
7)APPENDIX B
Base Level Drawing
8)APPENDIX C
Additional Calculations
RISATower Report-version 5.3.0.1
r ,
Crown Castle USA,Inc. May 15, 2009
118 Ft Monopole Tower Structural Analysis CC/BU No 875052
Project Number 2009184.47,Application 73650, Revision 2 Page 3
1) INTRODUCTION
The existing 118' monopole has 18 sides and is evenly tapered from 39.42" (flat-flat)at the base to 22.00" (flat-
flat)at the top of the tower. The tower has three major sections connected by slip joints.
This tower is a 118 ft Monopole tower designed by Summit Manufacturing in May of 2000. The tower was
originally designed for a wind speed of 105 mph per TIA/EIA-222-F.
2)ANALYSIS CRITERIA
The structural analysis was performed for this tower in accordance with the requirements of TIA/EIA-222-F
Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a fastest mile wind
speed of 100 mph with no ice, 86.6 mph with 0.5 inch ice thickness and 50 mph under service loads.
Table 1 -Proposed Antenna and Cable Information
M ..- �. cif$3 's��'�'a'�,�',- �r
aNumber �< z � �° umbers Feed
Mont of An n _ Antenna Model ;€ofTee, Lme Note
Level¢ ft F 'Elevation M Manufacturers �' * m �
��_� ) H tennas3 i ., �Lioes� Sizev(m)
i� -110 110 -
3 Kathrein 80010504 6 7/8
_ - - _ 1
3 Kathrein 860 10118 TMA's 1 3/8
Notes:
1) See Appendix"B"for proposed coax layout.
Table 2-Existing and Reserved Antenna and Cable Information
� �:
x Center � g � ufim
Mo�untrng Line of AntesWin-w
�of�FeedLrne Note
IaI
Antenna Model ,
Level{—t Elevation , Manufacturers � � ��� - (i��A
{ B Antennas k w Lines Size
��I�. � C+1. g��i I:�\� O �G"'x2 Y 3 t �b �
4 Comsat RSI PCSA065-16-00 4 1-5/8
118 119 2 1
CSA Wireless PCSA090-16-0 2 1-5/8
118�i 1 13' Platform
102 1 Celwave PD10183-1
95 101 1 Cushcraft CRS-3-50 3 7/8 3
95 2 2' Standoff
3 RFS Celwave APX16DWV-16DWV-S E-A20
88 88 1 3 RFS Celwave ATMAA1412D-lA20 TMA's 12 7/8 2
3 Ericsson KRY 112 71 TMA's
74 1 Lucent KS24019-Ll12A 1/2
73 73 1 2' Standoff 1
Notes:
1) Both the existing and MLA loadings were considered in this analysis. In this case,the MLA loading controls.
2) Both the reserved and SLA loadings were considered in this analysis.In this case,the reserved loading controls.
3) (1)7/8"coax is abandoned,and was considered in this analysis.
RISATower Report-version 5.3.0.1
I
Crown Castle USA, Inc. May 15, 2009
118 Ft Monopole Tower Structural Analysis CC/BU No 875052
Project Number 2009184.47,Application 73650,Revision 2 Page 4
Table 3- Design Antenna and Cable Information
I t { Number �, �. �� ` F � I Number Fesd
MountingLrne
VRM of �} antenna,Model of Feed E Line
#Lever{ftj Elevations� ZFE
� � Manufacturer � �
Antennas
�
?�
1 14' Low Profile Platform
118 118 1 5/8" Lightning Rod
ii-7 , Dapa 48000 PCS Panel
102.5 102.5 2 15'Whip Antennas
1 Omni-Antenna Clamp Mount_
14' Clamp-On Low Profile
88 gg 1 Paltform
12 Dapa 48000 PCS Panel
76 F76 1 F GPS Antenna
3)ANALYSIS PROCEDURE
Table 4-Documents Provided
-rlm" � � a n .:.
Document �emarks �� � Reference� Sourced
Original Tower Drawings Summit Job5:91S - 515, dated Doc ID#: 2145145 Crown DMZ
Foundation Drawings Summit Job#: 9154-A518, dated 5/1/2000 Doc ID#: 2145142 Crown DMZ
Geotechnical Report CHA Proj. #: 07.71, dated
3/30/2000 Doc ID#: 1430651 Crown DMZ
0/20
Previous Analysis PJF Proj.#: 115635, dated 3/8/09 Doc ID#:2397407 Crown DMZ
3.1) Analysis Method
RISATower(version.5.3.0.1), a commercially available analysis software package,was used to create
a three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) Tower and structures were built in accordance with the manufacturer's specifications.
2) The tower and structures have been maintained in accordance with the manufacturer's
specification.
3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
4) When applicable, transmission cables are considered as structural components for calculating
wind loads as allowed by TIA/EIA-222-F.
This analysis may be affected if any assumptions are not valid or have been made in error. GPD
Associates should be notified to determine the effect on the structural integrity of the tower.
RISATower Report-version 5.3.0.1
Crown Castle USA,Inc. May 15, 2009
118 Ft Monopole Tower Structural Analysis CC/BU No 875052
Project Number 2009184.47,Application 73650, Revision 2 Page 5
4)ANALYSIS RESULTS
Table 5-Section Capacity(Summary)
Bas,t�i�o-� W axsC�rs �Pass`?F�al N�o� �„ �.,- � �T p� �:�t .� �. •,Element (K1� p ��
L1 118-77.25 Pole TP28.318x22x0.1875 1 -3.85 787.88 72.4 Pass
L2 77.25-40.75 Pole TP33.602x27.4003x0.25 2 -7.71 1348.65 87.7 Pass
L3 40.75-0 Pole TP39.42x32.4431 x0.3125 3 -14.65 2016.56 94.9 Pass
Summary
Pole(0) 94.9 Pass
RATING= 94.9 Pass
Table 6-Tower Component Stresses vs. Capacity-LC1
ORION Comp
�
one Ele�atlon(ftj r �; °hapach►� �Pass/Fail
?� �ANN �
1 Anchor Rods 6.7.4 _ Pass
1 Base Plate 78.6 Pass
1 Base Foundation 86.9 Pass
Soil Interaction
— "-� . O— j 4 `r
� ctu�re ating(mafrom� nn�s) � 0
9N
Notes:
1) See additional documentation in"Appendix C—Additional Calculations"for calculations supporting the%capacity
consumed.
4.1) Recommendations
The designs of the tower and its foundation are sufficient for the proposed loading and do not require
modification.
RISATower Report-version 5.3.0.1
Crown Castle USA, Inc. May 15, 2009
118 Ft Monopole Tower.Structural Analysis CCI BU No 875052
Project Number 2009184.47,Application 73650, Revision 2 Page 6
5 DISCLAIMER OF WARRANTIES
GPD ASSOCIATES has not performed a site visit to the tower to verify the member sizes or antenna/coax
loading. If the existing conditions are not as represented on the tower elevation contained in this report, we
should be contacted immediately to evaluate the significance of the discrepancy. This is not a condition
assessment of the tower or foundation. This report does not replace a full tower inspection. The tower and
foundations are assumed to have been properly fabricated, erected, maintained, in good condition, twist free,
and plumb.
The engineering services rendered by GPD ASSOCIATES in connection with this Structural Analysis are limited
tower structure and theoretical capacity to a computer analysis of the to p ty of its main structural members. All tower
components have been assumed to only resist dead loads when no other loads are applied. No allowance was
made for any damaged, bent, missing, loose, or rusted members(above and below ground). No allowance was
made for loose bolts or cracked welds.
GPD ASSOCIATES does not'analyze the fabrication of the structure (including welding). It is not possible to
have all the very detailed information needed to perform a thorough analysis of every structural sub-component
and connection of an existing tower. GPD ASSOCIATES provides a limited scope of service in that we cannot
verify the adequacy of every weld, plate connection detail, etc. The purpose of this report is to assess the
feasibility of adding appurtenances usually accompanied by transmission lines to the structure.
It is the owners responsibility to determine the amount of ice accumulation, if any, that should be considered in
the structural analysis.
The attached sketches are a schematic representation of the analyzed tower. If any material is fabricated from
these sketches, the contractor shall be responsible for field verifying the existing conditions, proper fit, and
clearance in the field. Any mentions of structural modifications are reasonable estimates and should not be
used as a precise construction document. Precise modification drawings are obtainable from GPD
ASSOCIATES, but are beyond the scope of this report.
Miscellaneous items such as antenna mounts etc., have not been designed or detailed as a part of our work.
We recommend that material of adequate size and strength be purchased from a reputable tower manufacturer.
GPD ASSOCIATES makes no warranties, expressed and/or implied, in connection with this report and disclaims
any liability arising from material, fabrication, and erection of this tower. GPD ASSOCIATES will not be
responsible whatsoever for, or on account of, consequential or incidental damages sustained by any person,
firm, or organization as a result of any data or conclusions contained in this report. The maximum liability of
GPD ASSOCIATES pursuant to this report will be limited to the total fee received for preparation of this report.
RISATower Report-version 5.3.0.1
Crown Castle USA,Inc. May 15, 2009
118 Ft Monopole Tower Structural Analysis CC/BU No 875052
Project Number 2009184.47,Application 73650, Revision 2 Page 7
APPENDIX A
RISA TOWER OUTPUT
RISATower Report-version 5.3.0.1
118.0 R a
DESIGNED APPURTENANCE LOADING
TYPE ELEVATION TYPE ELEVATION
Valmont 13'Platform w/o rails GPD 118 12'Omni 95
(3)FV85.14-00NA2 w/Mormt Pipe 118 APX10DWV-18DWV-S-E-A20 88
(3)FV85.14-00NA2 w/Mood Pipe 118 APX16DWV-16DWV-S-E-A20 88
(3)FV05.14-OONA2 w/MowR Pipe 118 APX16DWV-18DWV-S-E-A20 88
800 10504 w/Mourd Pipe 110 ATMAA1412D-1A20 88
800 10504 w/Mound Pipe 110 ATMAA1412D-1A20 88
80010504 w/Mound Pipe 110 ATMAA1412D-1A20 88
860 10118 110 KRY 112 71 88
n A m 88010118 110 KRY 112 71 88
o R 'i 01 860 10118 110 KRY 112 71 88
"r 2'Standoff 95 2'Standoff 73
2'Standoff 95 KS24019-L112A 73
PD10183-1 95
MATERIAL STRENGTH
I GRADE Fy Fu GRADE Fy Fu
Ae07-80 e0 ksi 75 ksi A607.85 165 ksl I 8D ksi
TOWER DESIGN NOTES
? 1. Tower is located in Barnstable County,Massachusetts.
77.3 R 2. Tower designed for a 100 mph basic wind in accordance with the TIAIEIA-222-F
< Standard.
F 3. Tower is also designed for a 87 mph basic wind with 0.50 in ice.
4. Deflections are based upon a 50 mph wind.
5. TOWER RATING:94.9%
o
0 0 o ry O
V
N
N
� 40.8 R
'm
Q
AXIAL
g 19 K
ap N N <
N ' 6 N V N
SHEAR MOMENT
15 K 1272)dp-ft
TORQUE 0Idp-ft
87"ph WIND-0.5000 in ICE
AXIAL
15 K MOMENT
18 K 1526 kip ft
18
0.0 R
o TORQUE 0 k/p-ft
REACTIONS-100 rr)Dh WIND
9
E t] o 0
O
E
N J Z H J H m (7 zi
GPD Associates "Associated Alarm System BU#:87505
520 South Main St. Projed:2009184.47
Akron,Ohio 0lOn"Crown Castle Drawn by:*butterfiel Appd'
Phone:330-572-2100 code:TLAJEIA-222-F Date:05/15/09 Scab: NTS
FAX 330 572-1235 Pam'N.-M9Q0991B4a7u75487soszed Dwg No.E-1
Job Page
1IS'ATQwer� Associated Alarm S stem BU#: 875052 1 of 15
Y
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle
FAX:(330)572-1235 jbutterfield
Tower.In ut Data k
There is a pole section.
This tower is designed using the TIA/EIA-222-F standard.
The following design criteria apply.
Tower is located in Barnstable County,Massachusetts.
Basic wind speed of 100 mph.
Nominal ice thickness of 0.5000 in.
Ice density of 56 pcf.
A wind speed of 87 mph is used in combination with ice.
Temperature drop of 50'F.
Deflections calculated using a wind speed of 50 mph.
A non-linear(P-delta)analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.333.
Local bending stresses due to climbing loads,feedline supports,and appurtenance mounts are not considered
Consider Moments-Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder
Consider Moments-Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments-Diagonals 4 Assume Rigid Index Plate Calculate Redundant Bracing Forces
Use Moment Magnification 4 Use Clear Spans For Wind Area Ignore Redundant Members in FEA
Use Code Stress Ratios 4 Use Clear Spans For KL/r SR Leg Bolts Resist Compression
Use Code Safety Factors-Guys 4 Retension Guys To Initial Tension All Leg Panels Have Same Allowable
Escalate Ice J Bypass Mast Stability Checks Offset Girt At Foundation
Always Use Max Kz J Use Azimuth Dish Coefficients Consider Feedline Torque
Use Special Wind Profile 4 Project Wind Area of Appurt. Include Angle Block Shear Check
Include Bolts In Member Capacity J Autocalc Torque Arm Areas
Leg Bolts Are At Top Of Section SR Members Have Cut Ends Include Shear-Torsion Interaction
Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC.6D+W Combination
„ Feed Line/Linear APOR.,tenances.;= Entered As Area.
Description Face Allow Component Placement Total CAAA.' Weight
or Shield Type Number
Leg ft Aft plf
LDF4RN-50A(1/2 C No Inside Pole 73.00-8.00 1 No Ice 0.00 0.15
FOAM) 1/2"Ice 0.00 0.15
LDF5-50A(7/8 FOAM) B No Inside Pole 88.00-8.00 12 No Ice 0.00 0.33
1/2"Ice 0.00 0.33
LDF5-50A(7/8 FOAM) -A No Inside Pole 95.00-8.00 3 No Ice 0.00 0.33
1/2"Ice 0.00 0.33
LDF5-50A(7/8 FOAM) C No Inside Pole 110.00-8.00 6 No Ice 0.00 0.33
12"Ice 0.00 0.33
FSJ2-50(3/8') C No Inside Pole 110.00-8.00 1 No Ice 0.00 0.08
12"Ice 0.00 0.08
LDF7-50A(1-5/8 C No Inside Pole 118.00-8.00 9 No Ice 0.00 0.82
FOAM) 12"Ice 0.00 0.82
i
Feedline Distribution Chart
0'-118,
RoLM Flat App In Face App Oi4 Face Tn Leg
118.00 Face A Face B Face C 118.00
110.00 110.00
95.00 95.00
88.00 88.00
77.25 7725
73.00 73.00
f
O
LL
I\ m
b
O LL
� N N
' Q LL LL
W c o
Q LL
N �
� C
LL Q
� h
LL ()
0 LL
40.75
40.75
- c -
Z
lC
v
LL
8.00 8.00
0.00 0_00
GPD Associates lob:Associated Alarm System BU#:87505
520 South Main St. PmJsct:2009184.47
Akron,Ohio cner::Crown Castle I D'a`""by:ibutterfiel Appd:
Phone:330-572-2100 Code: TLA/EIA-222-F IDate:05/15/09 Scale: NTS
FAX 330 572-1235 aem:N:120092009184147 MSM875057ad Dvg No.E-7
.VISA Tower Jab Associated Alarm System BU#: 875052 Page2 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle jbutterfield
FAX.-(330)572-1235
t Discrete Tdwer t6dds . .
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustment Front Side
Leg Lateral
Vert
ft }I ft2 ft, K
ft
ft
Valmont 13P a tf 1 rm w/o C None 0.0000 118.00 No Ice 24.80 24.80 1.50
o
rails(GPD) 1/2"Ice 26.20 26.20 2.50
(3)FV65-14-00NA2 w/ A From 4.00 0.0000 118.00 No Ice 8.64 6.95 0.06
Mount Pipe Centroid-Le 0.00 1/2"Ice 9.29 8.13 0.12
g 0.00
(3)FV65-14-OONA2 w/ B From 4.00 0.0000 118.00 No Ice 8.64 6.95 0.06
Mount Pipe Centroid-Le 0.00 1/2"Ice 9.29 8.13 0.12
g 0.00
(3)FV65-14-OONA2 w/ C From 4.00 0.0000 118.00 No Ice 8.64 6.95 0.06
Mount Pipe Centroid-Le 0.00 1/2"Ice 9.29 8.13 0.12
g 0.00
800 10504 w/Mount Pipe A From Leg 0.47 20.0000 110.00 No Ice 3.59 3.18 0.04
0.17 1/2"Ice 4.01 3.91 0.07
0.00
800 10504 w/Mount Pipe B From Leg 0.47 20.0000 110.00 No Ice 3.59 3.18 0.04
0.17 1/2"Ice 4.01 3.91 0.07
0.00
800 10504 w/Mount Pipe C From Leg 0.47 20.0000 110.00 No Ice 3.59 3.18 0.04
0.17 1/2"Ice 4.01 3.91 0.07
0.00
860 10118 A From Leg 0.47 20.0000 110.00 No Ice 0.00 0.14 0.00
0.17 1/2"Ice 0.00 0.21 0.00.
0.00
860 10118 B From Leg 0.47 20.0000 110.00 No Ice 0.00 0.14 0.00
0.17 1/2"Ice 0.00 0.21 0.00
0.00
860 10118 C From Leg 0.47 20.0000 110.00 No Ice 0.00 0.14 0.00
0.17 1/2"Ice 0.00 0.21 0.00
0.00
2'Standoff A From Leg 1.00 0.0000 95.00 No Ice 1.36 1.36 0.02
0.00 1/2"Ice 2.45 2.45 0.04
0.00
2'Standoff C From Face 1.00 0.0000 95.00 No Ice 1.36 1.36 0.02
0.00 1/2"Ice 2.45 2.45 0.04
0.00
PD.10183-1 A From Leg 2.00 0.0000 95.00 No Ice 3.92 3.92 0.04
0.00 1/2"Ice 5.35 5.35 0.07
7.00
12'Omni C From Face 2.00 0.0000 95.00 No Ice 3.60 3.60 0.05
0.00 1/2"Ice 4.83 4.83 0.08
6.00
APXI6DWV-16DWV-S-E-A A From Leg 0.50 0.0000 88.00 No Ice 7.232.15 0.04
20 0.00 1/2"Ice 7.68 2.49 0.07
0.00
APXI6DWV-16DWV-S-E-A B From Leg 0.50 0.0000 88.00 No Ice 7.23 2.15 0.04
20 0.00 1/2"Ice 7.68 2.49 0.07
0.00
APXI6DWV-16DWV-S-E-A C From Leg 0.50 0.0000 88.00 No Ice 7.23 2.15 0.04
20 0.00 1/2"Ice 7.68 2.49 0.07
0.00
ATMAA1412D-1 A20 A From Leg 0.50 0.0000 88.00 No Ice 1.17 0.47 0.01
Job Page
* AT
O .
. Associated Alarm System BU#: 875052 3 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle jbutterfield
FAX.-(330)572-1135
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustment Front Side
Leg Lateral
Pert
ft ft ft2 f? K
ft
ft
0.00 1/2"Ice 1.31 0.57 0.02
0.00
ATMAA1412D-1 A20 B From Leg 0.50 0.0000 88.00 No Ice 1.17 0.47 0.01
0.00 1/2"Ice 1.31 0.57 0.02
0.00
ATMAA1412D-I A20 C From Leg 0.50 0.0000 88.00 No Ice 1.17 0.47 0.01
0.00 1/2"Ice 1.31 0.57 0.02
0.00
KRY 112 71 A From Leg 0.50 0.0000 88.00 No Ice 0.73 0.43 0.01
0.00 1/2"Ice 0.86 0.54 0.02
0.00
KRY 112 71 B From Leg 0.50 0.0000 88.00 No Ice 0.73 0.43 0.01
0.00 1/2"Ice 0.86 0.54 0.02
0.00
KRY 112 71 C From Leg' 0.50 0.0000 88.00 No Ice 0.73 0.43 0.01
0.00 1/2"Ice 0.86 0.54 0.02
0.00
2'Standoff A From Leg 1.00 0.0000 73.00 No Ice 1.36 1.36 0.02
0.00 1/2"Ice 2.45 2.45 0.04
0.00
KS24019-L112A A From Leg 2.00 0.0000 73.00 No Ice 0.16 0.16 0.01
0.00 1/2"Ice 0.22 0.22 0.01
1.00 .
Tower Pressuresx No Ice S � -
Gb=1.690
Section z Kz q= AG F AF An A, Leg CAAA CAAA
Elevation a % In Out
c Face Face
sf ft' e ft' ft2 f 2
Ll 97.08 1.361 35 85.436 A 0.000 85.436 85.436 100.00 0.000 0.000
118.00-71.25 B 0.000 85.436 100.00 0.000 0.000
C 0.000 85.436 100.00 0.000 0.000
L2 77.25-40.75 58.85 1.18 30 93.600 A 0.000 93.600 93.600 100.00 0.000 0.000
B 0.000 93.600 100.00 0.000 0.000
C 0.000 93.600 100.00 0.000 0.000
L3 40.75-0.00 19.78 1 26 123.136 A 0.000 123.136 123.136 100.00 0.000 0.000
B 0.000 123.136 100.00 0.000 0.000
C 0.000 123.136 100.00 0.000 0.000
77777771
Tower Pressure With Ic'e,
GR=1.690
Job Page
SA Tower Associated Alarm System BU#: 875052 4 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by,
Phone:330-572-2100 Crown Castle jbutterfield
FAX. (330)572-1235
Section z Kz q. tz AG F AF AR A,, Leg CAAA CAAA
Elevation a % In Out
C Face Face
ft fl Psf to f� e ft1 f� fta ft2 fta
L1118.00-77.25 97.08 1.361 26 0.5000 88.832 A 0.000 88.832 88.832 100.00 0.000 0.000
B 0.000 88.832 . 100.00 0.000 0.000
C 0.000 88.832 100.00 0.000 0.000
L2 77.25-40.75 58.85 1.18 23 0.5000 96.641 A 0.000 96.641 96.641 100.00 0.000 0.000
B 0.000 96.641 100.00 0.000 0.000
C 0.000 96.641 100.00 0.000 0.000
L3 40.75-0.00 19.78 1 19 0.5000 126.532 A 0.000 126.512 126*132 100.00 0.000 0.000
B 0.000 126.532 100.00 0.000 0.000
C 0.000 126.532 100.00 0.0001 0.000
Tower Pressure Service
Gg=1.690
Section z Kz qi AG F AF AR Arts Leg CAAA CAAA
Elevation a 0/0In Out
c Face Face
Psf ft2e
L1 97.08 1.361 9 85.436 A 0.000 85.436 85.436 100.00 0.000 0.000
118.00-77.25 B 0.000 85.436 100.00 0.000 0.000
C 0.000 85.436 100.00 0.000 0.000
L2 77.25-40.75 58.85 1.18 8 93.600 A 0.000 93.600 93.600 100.00 0.000 0.000
B 0.000 93.600 100.00 0.000 0.000
C 0.000 93.600 100.00 0.000 0.000
L3 40.75-0.00 19.78 1 6 123.136 A 0.000 123.136 123.136 100.00 0.000 0.000
B 0.000 123.136 100.00 0.000 0.000
C 1 0.0001 123.1361 1 100.001 0.0001 0.000
Towed Forces No. Ice Wind Normal T. Face
kEleva
n Add Self F e CF RR DF DR AE F w Ctrl.
on Weight Weight a Face
c
K K e K 1
Ll 0.43 2.06 A 1 0.65 1 1 1 85.436 3.26 80.09 C
77.25 B 1 0.65 1 1 1 85.436
C 1 0.65 1 1 1 85.436
L2 0.53 3.27 A 1 0.65 1 1 1 93.600 3.09 84.69 C
77.25-40.75 B 1 0.65 1 1 1 93.600
C 1 0.65 1 1 1 93.600
L3 40.75-0.00 0.48 5.41 A 1 0.65 1 1 1 123.136 3.46 84.98 C
B 1 0.65 1 1 1 123.136
C 1 0.65 1 1 1 123.136
Sum Weight: 1.43 10.74 OTM 567.24 9.82
ki -ft
f Job Page
* Associated Alarm System BU#: 875052 5 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle
FAX(330)572-1235
jbutterfield
Tower Forces No Ice -Wind 60°To Face x
y ,
Section Add Self F e CF RR DF DR AE F w Ctrl.
Elevation, Weight Weight a Face
c
K. K e ft2 K PIf
L1 0.43 2.06 A 1 0.65 1 1 1 85.436 3.26 80.09 C
118.00-77.25 B 1 0.65 1 1 1 85.436
C 1 0.65 1 1 1 85.436
L2 0.53 3.27 A 1 0.65 1 1 1 93.600 3.09 84.69 C
77.25.40.75 B 1 0.65 1 1 1 93.600
C 1 0.65 1 1 1 93.600
L3 40.75-0.00 0.48 5.41 A 1 0.65 1 1 1 123.136 3.46 84.98 C
B 1 0.65 1 1 1 123.136
C 1 0.65 1 1 1 123.136
Sum Weight: 1.43 10.74 OTM 567.24 9.82
ki -ft
r MEowerF No Ice '=W�nd�90 T�o Face
Section Add Self F e CF RR DF DR AE F w CH.
Elevation Weight Weight a Face
c
ft K K e ft, K pIf
Ll 0.43 2.06 A 1 0.65 1 1 1 85.436 3.26 80.09 C
118.00-77.25 B 1 0.65 1 1 1 85.436
C 1 0.65 1 1 1 85.436
L2 0.53 3.27 A 1 0.65 1 1 1 93.600 3.09 84.69 C
77.25-40.75 B 1 0.65 1 1 1 93.600
C 1 0.65 1 1 1 93.600
L3 40.75-0.00 0.48 5.41 A 1 0.65 1 1 1 123.136 3.46 84.98 C
B 1 0.65 1 1 1 123.136
C 1 0.65 1 1 1 123.136
Sum Weight: 1.43 10.74 OTM 567.24 9.82
ki -ft
Tower Forcesµ With Ice Wind Normal To Face
Section Add Sell' F e CF RR DF DR AE F w CH.
Elevation Weight Weight a Face
c
ft K K e ? K PIf
LI 0.43 2.71 A 1 0.65 1 1 1 88.832 2.54 62.45 C
118.00-77.25 B 1 0.65 1 1 1 88.832
C 1 0.65 1 1 - 1 88.832
L2 0.53 3.97 A 1 0.65 1 1 1 96.641 2.39 65.59 C
7725-40.75 B 1 0.65 1 1 1 96.641
C 1 0.65 1 1 1 96.641
L3 40.75-0.00 0.48 6.33 A 1 0.65 1 1 1 126.532 2.67 65.49 C
B 1 0.65 1 1 1 126.532
C 1 0.65 1 1 1 126.532
Sum Weight: 1.43 13.01 OTM 440.72 7.61
ki -ft
Job
M-SA Tower. Associated Alarm System BU M 875052 Page6 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle jbutterfield
FAX. (330)572-1235
` Tower Forces, With Ice Wind 60 To Face = ;
Section Add Self F e CF RR DF DR AE F w Ctrl.
Elevation Weight, Weight a Face
c
K K e K PIf
Ll 0.43 2.71 A 1 0.65 1 1 1 88.832 2.54 62.45 C
118.00-77.25 B 1 0.65 1 1 1 88.832
C 1 0.65 1 1 1 88.832
L2 0.53 3.97 A 1 0.65 1 1 1 96.641 2.39 65.59 C
7725-40.75 B 1 0.65 1 1 1 96.641
C 1 0.65 1 1 1 96.641
L3 40.75-0.00 0.48 6.33 A 1 0.65 1 1 1 126.532 2.67 65.49 C
B 1 0.65 1 1 1 126.532
C 1 0.65 1 1 1 126.532
Sum Weight: 1.43 13.01 OTM 440.72 7.61
ki -ft
Tower Forces f With Ice ` nd 90 To Face
Section Add Self F e CF RR DF DR AE F w CH.
Elevation Weight Weight a Face
c
K K e K PIf
Ll 0.43 2.71 A 1 0.65 1 1 1 88.832 2.54 62.45 C
118.00-77.25 B 1 0.65 1 1 1 88.832
C 1 0.65 1 1 1 88.832
L2 0.53 3.97 A 1 0.65 1 1 1 96.641 2.39 65.59 C
77.25-40.75 B 1 0.65 1 1 1 96.641
C 1 0.65 1 1 1 96,641
L3 40.75-0.00 0.48 6.33 A 1 0.65 1 1 1 126.532 2.67 65.49 C
B 1 0.65 1 1 1 126.532
C 1 0.65 1 1 1 126.532
Sum Weight: 1.43 13.01 OTM 440.72 7.61
ki -ft
Tower Forces-,Service Wind Normal To Face.
Section Add Self F e CF RR DF DR AE F w Ctrl.
Elevation Weight Weight a Face
c
ft K K e K DIf
LI 0.43 2.06 A 1 0.65 1 1 1 85.436 0.82 20.02 C
118.00-77.25 B 1 0.65 1 1 1 85.436
C 1 0.65 1 1 1 85.436
L2 0.53 3.27 A 1 0.65 1 1 1 93.600 0.77 21.17 C
77.25-40.75 B 1 0.65 1 1 1 93.600
C 1 0.65 1 1 1 93.600
L3 40.75-0.00 0.48 5.41 A 1 0.65 1 1 1 123.136 0.87 21.24 C
B 1 0.65 1 1 1 123.136
C 1 0.65 1 1 1 123.136
Sum Weight: 1.43 10.74 OTM 141.81 2.45
SA Tower Job Associated Alarm System BU#: 875052 Page7 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle
FAX.-(330)572-1235 JbUtterfield
Section Add Self F e CF RR DF DR AE F w CH.
Elevation Weight Weight a Face
c
ft K K e ft= K !f
ki -ft
Sepuice Wind 60 TotFace x 't r.
Section Add Self F e CF RR DF DR AE F w CH.
Elevation Weight Weight a Face
c
K K e K PIf
Ll 0.43 2.06 A 1 0.65 1 1 1 85.436 0.82 20.02 C
118.00-77.25 B 1 0.65 1 1 1 85.436
C 1 0.65 1 1 1 85.436
L2 0.53 3.27 A 1 0.65 1 1 1 93.600 0.77 21.17 C
77.25-40.75 B 1 0.65 1 1 1 93.600 '
C 1 0.65 1 1 1 93.600
L3 40.75-0.00 0.48 5.41 A 1 0.65 1 1 1 123.136 0.87 21.24 C
B 1 0.65 1 1 1 123.136
C 1 0.65 1 1 1 123.136
Sum Weight: 1.43 10.74 OTM 141.81 2.45
ki -ft
4 . a t'� ; . ,• � Tower Forces -w Se;;rwice „ .Wind 90r,To Fa"ce
Section Add Self F e CF RR DF DR AE F w Ctrl.
Elevation Weight Weight a Face
c
K K e ? K VIf
Ll 0.43 2.06 A 1 0.65 1 1 1 85.436 0.82 20.02 C
118.00-77.25 B 1 0.65 1 1 1 85.436
C 1 0.65 1 1 1 85.436
L2 0.53 3.27 A 1 0.65 1 1 1 93.600 0.77 21.17 C
77.25-40.75 B 1 0.65 1 1 1 93.600
C 1 0.65 1 1 1 93.600
L3 40.75-0.00 0.48 5.41 A 1 0.65 1 1 1 123.136 0.87 21.24 C
B 1 0.65 1 1 1 123.136
C 1 0.65 1 1 1 123.136
Sum Weight: 1.43 10.74 OTM 141.81 2.45
ki -ft
Discrete AppurtenancePressu�es - 4-0-pp,
I cg`=1690
Description Aiming Weight Offset Offset, z K q, CAAc CAAc
Azimuth Front Side
° K ft ft ft Psf
Valmont 13'Platform 0.0000 1.50 0.00 0.00 118.00 1.439 37 24.80 24.80
w/o rails(GPD)
FV65-14-OONA2 w/ 0.0000 0.18 0.00 4.60 118.00 1.439 37 25.91 20.84
Mount Pipe
Job Page'
SA.Tower Associated Alarm System BU#: 875052 8 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle jbutterfield
FAX. (330)572-1235
Description Aiming Weight Offs e. Offs e. z K. q, CAA F20.84
CAA
Azimuth Fronte
° K s
FV65-14-OONA2 w/ 120.0000 0.18 3.46 2.00 118.00 1.439 37 25.9120.84
Mount Pipe
FV65-14-OONA2 w/ 240.0000 0.18 -3.46 2.00 118.00 1.439 37 25.91
Mount Pipe
800 10504 w/Mount 20.0000 0.04 0.17 -1.44 110.00 1.411 36 3.59 3.18
Pipe
800 10504 w/Mount 140.0000 0.04 1.16 0.87 110.00 1.411 36 3.59 3.18
Pipe
800 10504 w/Mount 260.0000 0.04 -1.33 0.57 110.00 1.411 36 3.59 3.18
Pipe
86010118 20.0000 0.00 0.17 -1.44 110.00 1.411 36 0.00 0.14
86010118 140.0000 0.00 1.16 0.87 110.00 1.411 36 0.00 0.14
86010118 260.0000 0.00 -1.33 0.57 110.00 1.411 36 0.00 0.14
2'Standoff 0.0000 0.02 0.00 -2.07 95.00 1.353 35 1.36 1.36
2'Standoff 180.0000 0.02 0.00 2.07 95.00 1.353 35 1.36 1.36
PD10183-1 0.0000 0.04 0.00 -3.07 102.00 1.380 35 3.92 3.92
12'Omni 180.0000 0.05 0.00 3.07 101.00 1.377 35 3.60 3.60
APX16DWV-16DWV-S- 0.0000 0.04 0.00 -1.61 88.00 1.323 34 7.23 2.15
E-A20
APX16DWV-16DWV-S- 120.0000 0.04 1.39 0.81 88.00 1.323 34 7.23 2.15
E-A20
APX16DWV-16DWV-S- 240.0000 0.04 -1.39 0.81 88.00 1.323 34 7.23 2.15
E-A20
ATMAA1412D-1A20 0.0000 0.01 0.00 -1.61 88.00 1.323 34 1.17 0.47
ATMAA1412D-1A20 120.0000 0.01 1.39 0.81 88.00 1.323 34 1.17 0.47
ATMAA1412D-1A20 240.0000 0.01 -1.39 0.81 88.00 1.323 34 1.17 0.47
KRY 112 71 0.0000 0.01 0.00 -1.61 88.00 1.323 34 0.73 0.43
KRY 112 71 120.0000 0.01 1.39 0.81 88.00 1.323 34 0.73 0.43
KRY 112 71 240.0000 0.01 -1.39 0.81 88.00 1.323 34 0.73 0.43
2'Standoff 0.0000 0.02 0.00 -2.19 73.00 1.255 32 1.36 1.36
KS24019-LI12A 0,0000 0.01 0.00 -3.19 74.00 1.260 32 0.16 0.16
Sum 2.50
Weight:
D�scete Appurtenance Pressures = With lce„ cg 1690
Description Aiming Weight Ofjse. Offset. z K q, CAA CAAc t,
Azimuth Front Side
° K Psfin
Valmont 13'Platform 0.0000 2.50 0.00 0.00 118.00 1.439 28 26.20 26.20 0.5000
w/o rails(GPD)
FV65-14-OONA2 w/ 0.0000 0.36 0.00 4.00 118.00 1.439 28 27.87 24.38 0.5000
Mount Pipe
FV65-14-OONA2 w/ 120.0000 0.36 3.46 2.00 118.00 1.439 28 27.87 24.38 0.5000
Mount Pipe
FV65-14-OONA2 w/ 240.0000 0.36 -3.46 2.00 118.00 1.439 28 27.87 24.38 0.5000
Mount Pipe
800 10504 w/Mount 20.0000 0.07 0.17 -1.44 110.00 1.411 27 4.01 3.91 0.5000
Pipe
800 10504 w/Mount 140.0000 0.07 1.16 0.87 110.00 1.411 27 4.01 3.91 0.5000
Pipe
800 10504 w/Mount 260.0000 0.07 -1.33 0.57 110.00 1.411 27 4.01 3.91 0.5000
Pipe
86010118 20.0000 0.00 0.17 -1.44 110.00 1.411 27 0.00 0.21 0.5000
86010118 140.0000 0.00 1.16 0.87 110.00 1.411 27 0.00 0,21 0.5000
86010118 260.0000 0.00 -1.33 0.57 110.00 1.411 27 0.00 0.21 0.5000
2'Standoff 0.0000 0.04 0.00 -2.07 95.00 1.353 26 2.45 2.45 0.5000
2'Standoff 180.0000 0.04 0.00 2.07 95.00 1.353 26 2.45 2.45 0.5000
�?'AaR t` Job Page
Associated Alarm System BU#: 875052 9 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle
FAX-(330)572-1235 jbutterfield
Description Aiming Weight Offset. Offset z K q= CAAc CAA 4
Azimuth Front Side
° K ft ft fi Psfa in
PD10183-1 0.0000 0.07 0.00 -3.07 102.00 1.380 27 5.35 5.35 0.5000
12'Omni 180.0000 0.08 0.00 3.07 101.00 1.377 26 4.83 4.83 0.5000
APX16DWV-16DWV-S- 0.0000 0.07 0.00 -1.61 88.00 1.323 25 7.68 2.49 0.5000
E-A20
APX16DWV-16DWV-S- 120.0000 0.07 1.39 0.81 88.00 1.323 25 7.68 2.49 0.5000
E-A20
APX16DWV-16DWV-S- 240.0000 0.07 -1.39 0.81 88.00 1.323 25 7.68 2.49 0.5000
E-A20
ATMAA1412D-1A20 0.0000 0.02 0.00 -1.61 88.00 1.323 25 1.31 0.57 0.5000
ATMAA1412D-iA20 120.0000 0.02 1.39 0.81 88.00 1.323 25 1.31 0.57 0.5000
ATMAA1412D-1 A20 240.0000 0.02 -1.39 0.81 88.00 1.323 25 1.31 0.57 0.5000
KRY 112 71 0.0000 0.02 0.00 -1.61 88.00 1.323 25 0.86 0.54 0.5000
KRY 112 71 120.0000 0.02 1.39 0.81 88.00 1.323 25 0.86 0.54 0.5000
KRY 112 71 240.0000 0.02 -1.39 0.81 88.00 1.323 25 0.86 0.54 0.5000
2'Standoff 0.0000 0.04 0.00 -2.19 73.00 1.255 24 2.45 2.45 0.5000
KS24019-L112A 0.0000 0.01 0.00 -3.19 74.00 1.260 24 0.22 0.22 0.5000
Sum 4.42
Weight:
x Discrete Appurtenance P,ressur�es> Service; } cH �490
Description Aiming Weight Offs e: Offset. z K q= CAAc CAA
Azimuth Front Side
° K ft ft ft Psf
Valmont 13'Platform 0.0000 1.50 0.00 0.00 118.00 1.439 9 24.80 24.80
w/o rails(GPD)
FV65-14-OONA2 w/ 0.0000 0.18 0.00 4.00 118.00 1.439 9 25.91 20.84
Mount Pipe
FV65-14-OONA2 w/ 120.0000 0.18 3.46 2.00 118.00 1.439 9 25.91 20.84
Mount Pipe
FV65-14-OONA2 w/ 240.0000 0.18 -3.46 2.00 118.00 1.439 9 25.91 20.84
Mount Pipe
800 10504 w/Mount 20.0000 0.04 0.17 -1.44 110.00 1.411 9 3.59 3.18
Pipe
800 10504 w/Mount 140.0000 0.04 1.16 0.87 110.00 1.411 9 3.59 3.18
Pipe
800 10504 w/Mount 260.0000 0.04 -1.33 0.57 110.00 1.411 9 3.59 3.18
Pipe
86010118 20.0000 0.00 0.17 -1.44 110.00 1.411 9 0.00 0.14
86010118 140.0000 0.00 1.16 0.87 110.00 1.411 9 0.00 0.14
86010118 260.0000 0.00 -1.33 0.57 110.00 1.411 9 0.00 0.14
2'Standoff 0.0000 0.02 0.00 -2.07 95.00 1.353 9 1.36 1.36
2'Standoff 180,0000 0.02 0.00 2.07 95.00 1.353 9 1.36 1.36
PD10183-1 0.0000 0.04 0.00 -3.07 102.00 1.380 9 3.92 3.92
12'Omni 180.0000 0.05 0.00 3.07 101.00 1.377 9 3.60 3.60
APX16DWV-16DWV-S- 0.0000 0.04 0.00 -1.61 88.00 1.323 8 7.23 2.15
E-A20
APX16DWV-16DWV-S- 120.0000 0.04 1.39 0.81 88.00 1.323 8 7.23 2.15
E-A20
APX16DWV-16DWV-S- 240.0000 0.04 -1.39 0.81 88.00 1.323 8 7.23 2.15
E-A20
ATMAA1412D-1 A20 0.0000 0.01 0.00 -1.61 88.00 1.323 8 1.17 0.47
ATMAA1412D-1 A20 120.0000 0.01 1.39 0.81 88.00 1.323 8 1.17 0.47
ATMAA1412D-1 A20 240.0000 0.01 -1.39 0.81 88.00 1.323 8 1.17 0.47
KRY 112 71 0.0000 0.01 0.00 -1.61 88.00 1.323 8 0.73 0.43
KRY 112 71 120.0000 0.01 1.39 0.81 88.00 1.323 8 0.73 0.43
KRY 112 71 240.0000 0.01 -1.39 0.81 88.00 1.323 8 0.73 0.43
2'Standoff 0.0000 0.02 0.00 -2.19 73.00 1.255 8 1.36 1.36
I
PU SA To,we r Job Associated Alarm Page System BU#: 875052 10 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle jbutterfield
FAX.-(330)572-1235
Description Aiming Weight Offs . Offs etz z K q= CAAc CAC
Azimuth Front Side
° K ft Psf
KS24019-L112A 0.0000 0.01 0.00 -3.19 74.00 1.260 8 0.16 0.16
Sum 2.50
Weight:
Load Vertical Sum of Sum of Sum of Sum of Sum of Torques
Case Forces Forces Forces Overturning Overturning
X Z Moments,M. Moments,M
K K K kip-ft kip-f1 kip-ft
Leg Weight 10.74
Bracing Weight 0.00
Total Member Self-Weight 10.74 -0.03 0.00
Total Weight 14.67 -0.03 0.00
Wind 0 deg-No Ice 0.00 -18.10 -1492.94 0.00 0.00
Wind 30 deg-No Ice 9.05 -15.67 -1292.93 -746.46 -0.12
Wind 60 deg-No Ice 15.67 -9.05 -746.48 -1292.90 -022
Wind 90 deg-No Ice 18.10 0.00 -0.03 -1492.91 -0.25
-1292.90 -0.22
1 9.05 746.43
Wind 120 de -No Ice 5.67
g
Wind 150 deg-No Ice 9.05 15.67 1292.87 -746.46 -0.12
Wind 180 deg-No Ice 0.00 18.10 1492.88 0.00 0.00
Wind 210 deg-No Ice -9.05 15.67 1292.87 746.46 0.12
Wind 240 deg-No Ice -15.67 9.05 '746.43 1292.90 022
Wind 270 deg-No Ice -18.10 0.00 -0.03 1492.91 0.25
Wind 300 deg-No Ice -15.67 -9.05 -746.48 1292.90 0.22
Wind 330 deg-No Ice -9.05 -15.67 1292.93 746.46 0.12
Member Ice 2.27
Total Weight Ice 18.86 -0:09 0.00
Wind 0 deg-Ice 0.00 -14.69 -1229.31 0.00 0.00
Wind 30 deg-Ice 7.35 -12.73 -1064.62 614.61 -0.16
Wind 60 deg-Ice 12.73 -7.35 -614.70 -1064.53 -0.28
Wind 90 deg-Ice 14.69 0.00 -0.09 -1229.22 -0.32
Wind 120 deg-Ice 12.73 7.35 614.52 -1064.53 -0.28
Wind 150 deg-Ice 7.35 12.73 1064.45 -614.61 -0.16
Wind 180 deg-Ice 0.00 14.69 1229.13 0.00 0.00
Wind 210 deg-Ice -7.35 12.73 1064.45 614.61 0.16
Wind 240 deg-Ice -12.73 7.35 614.52 1064.53 0.28
Wind 270 deg-Ice -14.69 0.00 -0.09 1229.22 0.32
Wind 300 deg-Ice -12.73 -7.35 -614.70 1064.53 0.28
Wind 330 deg-Ice -7.35 -12.73 -1064.62 614.61 0.16
Total Weight 14.67REMESHME -0.03 0.00
Wind 0 deg-Service 0.00 -4.52 -373.26 0.00 0.00
Wind 30 deg-Service 2.26 -3.92 -323.25 -186.61 -0.03
Wind 60 deg-Service 3.92 -2.26 -186.64 -323.22 -0.05
Wind 90 deg-Service 4.52 0.00 -0.03 373.23 -0.06
Wind 120 deg-Service 3.92 2.26 186.58 -323.22 -0.05
Wind 150 deg-Service 2.26 3.92 323.20 -186.61 -0.03
Wind 180 deg-Service 0.00 4.52 373.20 0.00 0.00
Wind 210 deg-Service -2.26 3.92 323.20 186.61 0.03
Wind 240 deg-Service -3.92 2.26 186.58 323.22 0.05
Wind 270 deg-Service -4.52 0.00 -0.03 373.23 0.06
Wind 300 deg-Service 3.92 -2.26 -186.64 323.22 0.05
Wind 330 de -Service 2.26 -3.92 -323.25 186.61 0.03
Job Page
JUSA Tower Associated Alarm System BU#: 875052 11 of 15
GPD Associates Project Date
520 South Main St:
2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle(3 terfield
FAX. 30)572-1235 jbUt
M`azimum Member Forces f,._ ,_
Section Elevation Component Condition Gov. Force Major Axis Minor Axis
No. jt Type Load Moment Moment
Comb. K kip ft kip ft
Ll 118 77
.25 Pole Max Tension 1 0.00 0.00 0.00
Max.Compression 14 -721 0.00
Max.Mx 5 -3.85 321.33 -0.03
Max.My 8 -3.85 0.00 -321.36
Max.Vy 5 11.49 -321.33 -0.03
Max.Vx 2 -11.49 0.00 321.30
Max.Torque 18 0.07
L2 77.25-40.75 Pole Max Tension 1 0.00 0.00 0.00
Max.Compression 14 -11.52 0.00 0.09
Max.Mx 11 -7.71 789.58 0.03
Max.My 2 -7.71 0.00 789.61
Max.Vy 11 -14.62 789.58 0.03
Max.Vx 2 -14.62 0.00 789.61
Max.Torque 18 0.32
L3 40.75-0 Pole Max Tension 1 0.00 0.00 0.00
Max.Compression 14 -18.86 0.00 0.09
Max.Mx 11 -14.65 1526.30 0.03
Max.My 2 -14.65 0.00 1526.33
Max.Vy 11 -18.11 1526.30 0.03
Max.Vx 2 -18.11 0.00 1526.33
Max.Torque 18 0.32
7777771
_ � - Maximum Reactions �`
Location Conditio
n Gov. Vertical
l Horizontal,
ntal X Horizontal,Z
`
Load K K K
Comb.
Pole Max.Vert 15 18.86 0.00 14.69
Max.H. 11 14.67 18.10 0.00
Max.H. 2 14.67 0.00 18.10
Max.Mx 2 1526.33 0.00 18.10
Max.Mx 5 1526.30 -18.10 0.00
Max.Torsion 18 0.32 -14.69 0.00
Min.Vert 1 14.67 0.00 0.00
Min.Hx 5 14.67 -18.10 0.00
Min.H. 8 14.67 0.00 -18.10
Min.Mx 8 -1526.27 0.00 -18.10
Min.Mx 11 -1526.30 18.10 0.00
Min.Torsion 24 -0.32 14.69 0.00
Towe-Mast Reaction Sulmma ,
Load Vertical Shear. Shear, Overturning Overturning Torque
Combination Moment,M. Moment,M.
K K K kip-ft kip II kip
Dead Only 14.67 0.00. 0.00 -0.03 0.00 0.00
Dead+Wind 0 deg-No Ice 14.67 0.00 -18.10 -1526.33 0.00 0.00
Dead+Wind 30 deg-No Ice 14.67 9.05 -15.67 1321.84 -763.15 -0.12
Dead+Wind 60 deg-No Ice 14.67 15.67 =9.05 -763.18 -1321.81 -0.21
Dead+Wind 90 deg-No Ice 14.67 18.10 -0.00 -0.03 -1526.30 -0.25
RIBA To,wer Job Page Associated Alarm System BU#: 875052 12 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle jbutterfield
FAX.•(330)572-1235
Load Vertical Shear, Shear, Overturning Overturning Torque
Combination Moment,M. Moment,M.
K K K kip ft kip-ft kip-ft
Dead+Wind 120 deg-No Ice 14.67 15.67 9.05 763.12 -1321.81 -0.21
Dead+Wind 150 deg-No Ice 14.67 9.05 15.67 1321.78 -763.15 -0.12
Dead+Wind 180 deg-No Ice 14.67 0.00 18.10. 1526.27 0.00 0.00
Dead+Wind 210 deg-No Ice 14.67 -9.05 15.67 1321.78 763.15 0.12
Dead+Wind 240 deg-No Ice 14.67 -15.67 9.05 763.12 1321.81 021
Dead+Wind 270 deg-No Ice 14.67 -18.10 -0.00 -0.03 1526.30 0.25
Dead+Wind 300 deg-No Ice 14.67 -15.67 -9.05 -763.18 1321.81 0.21
Dead+Wind 330 deg-No Ice 14.67 -9.05 -15.67 -1321.84 763.15 0.12
Dead+Ice+Temp 18.86 0.00 0.00 -0.09 0.00 0.00
Dead+Wind 0 deg+Ice+Temp 18.86 0.00 -14.69 -1271.59 0.00 0.00
Dead+Wind 30 deg+Ice+Temp 18.86 7.35 -12.73 -1101.24 -635.75 -0.16
Dead+Wind 60 deg+Ice+Temp 18.86 12.73 -7.35 -635.84 1101.15 -0.27
Dead+Wind 90 deg+Ice+Temp 18.86 14.69 0.00 -0.09 -1271.49 -0.32
Dead+Wind 120 deg+Ice+Temp 18.86 12.73 7.35 635.66 -1101.15 -0.27
Dead+Wind 150 deg+Ice+Temp 18.86 7.35 12.73 1101.05 -635.75 -0.16
Dead+Wind 180 deg+Ice+Temp 18.86 0.00 14.69 1271.40 0.00 0.00
Dead+Wind 210 deg+Ice+Temp 18.86 -7.35 12.73 1101.05 635.75 0.16
Dead+Wind 240 deg+Ice+Temp 18.86 -12.73 7.35 635.66 1101.15 0.27
Dead+Wind 270 deg+Ice+Temp 18.86 -14.69 0.00 -0.09 1271.49 0.32
Dead+Wind 300 deg+Ice+Temp 18.86 -12.73 -7.35 -635.84 1101.15 027
Dead+Wind 330 deg+Ice+Temp 18.86 -7.35 -12.73 -1101.24 635.75 0.16
Dead+Wind 0 deg-Service 14.67 0.00 -4.52 -382.18 0.00 0.00
Dead+Wind 30 deg-Service 14.67 2.26 -3.92 -330.98 -191.07 -0.03
Dead+Wind 60 deg-Service 14.67 3.92 -2.26 -191.10 -330.95 -0.05
Dead+Wind 90 deg-Service 14.67 4.52 0.00 -0.03 -382.15 -0.06
Dead+Wind 120 deg-Service 14.67 3.92 2.26 191.04 -330.95 -0.05
Dead+Wind 150 deg-Service 14.67 2.26 3.92 330.92 -191.07 -0.03
Dead+Wind 180 deg-Service 14.67 0.00 4.52 382.12 0.00 0.00
Dead+Wind 210 deg-Service 14.67 -2.26 3.92 330.92 191.07 0.03
Dead+Wind 240 deg-Service 14.67 -3.92 2.26 191.04 330.95 0.05
Dead+Wind 270 deg-Service 14.67 4.52 0.00 -0.03 382.15 0.06
Dead+Wind 300 deg-Service 14.67 -3.92 -2.26 -191.10 330.95 0.05
Dead+Wind 330 deg-Service 14.67 -2.26 -3.92 -330.98 191.07 0.03
Solution Summary
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ %Error
Comb. K K K K K K
1 0.00 -14.67 0.00 0.00 14.67 0.00 0.000%
2 0.00 -14.67 -18.10 0.00 14.67 18.10 0.000%
3 9.05 -14.67 -15.67 -9.05 14.67 15.67 0.000%
4 15.67 -14.67 -9.05 -15.67 14.67 9.05 0.000%
5 18.10 -14.67 0.00 -18.10 14.67 0.00 0.000%
6 15.67 -14.67 9.05 -15.67 14.67 -9.05 0.000%
7 9.05 -14.67 15.67 -9.05 14.67 -15.67 0.000%
8 0.00• -14.67 18.10 0.00 14.67 -18.10. 0.000%
9 -9.05 -14.67 15.67 9.05 14.67 -15.67 0.000%
10 -15.67 -14.67 9.05 15.67 14.67 -9.05 0.000%
11 -18.10 -14.67 0.00 18.10 14.67 0.00 0.000%
12 -15.67 -14.67 -9.05 15.67 14.67 9.05 0.000%
13 -9.05 -14.67 -15.67 9.05 14.67 15.67 0.000%
14 0.00 -18.86 0.00 0.00 18.86 0.00 0.000%
15 0.00 -18.86 -14.69 0.00 18.86 14.69 0.000%
16 7.35 -18.86 -12.73 -7.35 18.86 12.73 .0.000%
17 12.73 -18.86 -7.35 -12.73 18.86 7.35 0.000%
18 14.69 -18.86 0.00 .-14.69 18.86 0.00 0.000%
19 12.73 -18.86 7.35 -12.73 18.86 -7.35 0.000%
RISA To,wer Job Associated Alarm System BU#: 875052 Page13 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crown Castle jbutterfield
FAX.-(330)572-1235
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ %Error
Comb. K K K K K K
20 7.35 18.86 12.73 -7.35 18.86 -12.73 0.000%
21 0.00 -18.86 14.69 0.00 18.86 -14.69 0.000%
22 -7.35 -18.86 12.73 7.35 18.86 -12.73 0.000%
23 -12.73 -18.86 7.35 12.73 18.86 -7.35 0.000%
24 -14.69 -18.86 0.00 14.69 18.86 0.00 0.000%
25 -12.73 -18.86 -7.35 12.73 18.86 7.35 0.000%
26 -7.35 -18.86 -12.73 7.35 18.86 12.73 0.000%
27 0.00 -14.67 -4.52 0.00 14.67 4.52 0.000%
28 2.26 -14.67 -3.92 -2.26 14.67 3.92 0.000%
29 3.92 -14.67 -2.26 -3.92 14.67 2.26 0.000%
30 4.52 -14.67 0.00 -4.52 14.67 0.00 0.000%
31 3.92 -14.67 2.26 -3.92 14.67 -2.26 0.000%
32 2.26 -14.67 3.92 -2.26 14.67 -3.92 0.000%
33 0.00 -14.67 4.52 0.00 14.67 4.52 0.000%
34 -2.26 -14.67 3.92 2.26 14.67 -3.92 0.000%
'
35 -3.92 -14.67 2.26 3.92 14.67 -2.26 0.000%
36 -4.52 -14.67 0.00 4.52 14.67 0.00 0.000%
37 -3.92 -14.67 -2.26 3.92 14.67 2.26 0.000%
38 -2.26 -14.67 -3.92 2.26 14.67 3.92 0.000%
Maximum Tower Deflections, Service Wind`
Section Elevation Hon. Gov. Tilt Twist
No. Deflection Load
ft in Comb. o °
Ll 118-77.25 19.748 27 1.4029 0.0005
L2 80.75-40.75 9.628 27 1.1026 0.0004
L3 45-0 3.039 27 0.6138 0.0002
Crticai Deflections and_Radiusof Cur\rature„ Service Wind .,
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in ft
118.00 Valmont 13'Platform w/o rails 27 19.748 1.4029 0.0005 33465
(GPD)
1.10.00 800 10504 w/Mount Pipe 27 17.448 1.3562 0.0005 20915
95.00 2'Standoff 27 13.263 1.2506 0.0005 7274
88.00 APXI6DWV-16DWV-S-E-A20 27 11.423 1.1856 0.0004 5576
i
73.00 2'Standoff 27 7.862 0.9949 0.0004 4131
9
Section Elevation Harz. Gov. Tilt Twist
fl
No. Deflection Load.
ft in Comb. °
Ll 118-77.25 78.724 2 5.5955 0.0024
► A Tourer Job Associated Alarm System BU#: 875052. Page14 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crowd Castle jbutterfield
FAX.-(330)572-1235
Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
ft in Comb. o °
L2 80.75-40.75 38.408 2 4.3991 0.0021
L3 45-0 12.130 2 2.4503 0.0009
Cr�t�cal Deflections and Radius„ofCurvatye
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in 0 oft
118.00 Valmont 13'Platform w/o rails 2 78.724 5.5955 0.0024 8539
(GPD)
110.00 800 10504 w/Mount Pipe 2 69.563 5.3909 0.0024 5336
95.00 2'Standoff 2 52.893 4.9544 0.0023 1853
88.00 APXI6DWV-16DWV-S-E-A20 2 45.560 4.7043 0.0023 1419
73.00 2'Standoff 2 31.369 4.0148 0.0019 1047
Compression Chucks
Pole De .1 n Data
Section Elevation Size L Lu Kl/r F. A Actual Allow. Ratio
No. P P P
ft ft ft ksi in K K P
Ll 118-77.25(1) TP28.318x22x0.1875 40.75 0.00 0.0 36.000 16.4182 -3.85 591.06 0.007
L2 77.25-40.75(2) TP33.602x27.40030.25 40.00 0.00 0.0 39.000 25.9420 -7.71 1011.74 0.008
L3 40.75-0(3) TP39.4202.44310.3125 45.00 0.00 0.0 39.000 38.7898 -14.65 1512.80 0.010
Pole Bendin Desi n Data
Section Elevation Sue Actual Actual Allow. Ratio Actual Actual Allow. Ratio
No. M. fbs Fb. fb= Mr fby Fby fbr
ft kip ft ksi ksi F, kip-ft ksi ksi Fbv
L1 118-77.25(1) TP28.318x22x0.1875 321.36 34.467 36.000 0.957 0.00 0.000 36.000 0.000
L2 77.25-40.75 TP33.60WT40030.25 789.61 45.266 39.000 1.161 0.00 0.000 39.000 0.000
(2)
L3 40.75-0(3) TP39.4202.44310.3125 1526.33 48.937 39.000 1.255 0.00 0.000 39.000 0.000
Pole'Shear Deli In:Data
Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio
No. V f F f T fw F. fw
ft K ksi ksi F kip ft ksi ksi Fw
Ll 118-77.25(1) TP28.318x22x0.1875 11.49 0.700 24.000 0.058 0.00 0.000 24.000 0.000
Job Page
* AT Associated Alarm System BU#: 875052 15 of 15
GPD Associates Project Date
520 South Main St. 2009184.47 10:02:22 05/15/09
Akron,Ohio Client Designed by
Phone:330-572-2100 Crowd Castle
FAX.-(330)572-1235
jbutterfield
Section Elevation Size Actual Actual Allow. Ratio Actual Actual Allow. Ratio
No. V .fw F f T fw Fw fw
ft K ksi ksi F kip ft ksi ksi Fw
L2 77.25-40.75 TP33.602x27.4003x0.25 14.62 0.563 26.000 0.043 0.12 0.003 26.000 0.000
(2)
L3 40.75-0(3) TP39.4202.4431x0.3125 18.11 0.467 26.000 0.036 0.00 0.000 26.000 0.000
Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria
No. P fb. fbr ff fw Stress Stress
ft P. Fb. Fby F Fw Ratio Ratio ,r
Ll 118-77.25(1) 0.007 0.957 0.000 0.058 0.000 0.965 1.333 Hl-3+VT
• IF
L2 77.25-40.75 0.008 1.161 0.000 0.043 0.000 1.169 1.333 H1 3+VT Mf
(2) ✓
L3 40.75-0(3) 0.010 1.255 0.000 0.036 0.000 1.265 1.333 Hl-3+VT
Sect on,C;a O Table
Section Elevation Component Size Critical P SF*P rlaw % Pass
No. ft Type Element K K Capacity Fail
Ll 118-77.25 Pole TP28.318x22x0.1875 1 -3.85 787.88 72.4 Pass
L2 77.25-40.75 Pole TP33.602x27.40030.25 2 -7.71 1348.65 87.7 Pass
L3 40.75-0 Pole TP39.4202.4431x0.3125 3 -14.65 2016.56 94.9 Pass
Summary
Pole(L3) 94.9 Pass
RATING= 94.9 Pass
Program Version 5.3.0.1-9/9/2008 File:N:/2009/2009184/47/RISA/875052.eri
Crown Castle USA, Inc. May 15, 2009
118 Ft Monopole Tower Structural Analysis CC/BU No 875052
Project Number 2009184.47,Application 73650, Revision 2 Page 8
APPENDIX B
BASE LEVEL DRAWING
RISATower Report-version 5.3.0.1
(ABANDONED)
(1)7/8-TO 95 FT LEVEL -
(INSTALLED)
(2)7/8-TO 95 FT LEVEL
_ CLIMBING PEGS M�
W/SAFETY CLIMB
(MLA) /
(()) 1 5/8;TO I I B FT LEVEL
(
(6) 1-5/8'TO 118 FT LEVEL
(1)1/2-TO 73 FT LEVEL
0
(PROPOSED)
(s)7/e'Ta no FT LEVEL •oo\\ ��
TO 1l0 Ff LEVEL (SLA)
i (6)7/8-TO 88 FT LEVEL
(RESERVED-IN ADDITION TO INSTALLED)
(6)7/8'TO BB FT LEVEL
(INSTALLED) B
(6)7/8-TO 88 FT LEVEL �®
DRAWN BY: ANE
. - CHECKED W. COB
DRAVVNG DATE 27102107
SITE NUMBER:
SITE NAME
_ SITE NAME -
ASSOCIATED ALARM SYSTEM
BUSINESS UNIT NUMBER
876062
LEGEND: FEEDLINES I SITE ADDRESS
O 'I 2 3FT SOLID BLUE CD3CLE DENOTES EXISTING FEEDLINE 1007 FALMOUTH RD
HYANNIS.MA 02601
O OPEN RED CIRCLE DENOTES PROPOSED FEEDLINE BARNSTABLE COUNTY
BUSINESS UNIT:575052 TOWER ID:C-BASOXVEL O OPEN BLUE CIRCLE DENOTES RESERVED FEEDLINE USA
X BLUE 'X" DENOTES LOCATION NOT GIVEN I SHEET TITLE
SCALE
NOTE ASSUME FEEDLINE ATTACHMENT HEIGHT TO TOWER STEEL BASE LEVEL
AT B-FEET ABOVE FINISHED GRADE UNLESS OTHERWISE SPECIFIED_ SHEET NUMBER
BASE LEVEL DRAWING �'e
.„,.RL9.LU9IE..SlJAl2.092....ALE.C�AMELkZSQS��AS€4E�L-aye .
Crown Castle USA, Inc. May 15, 2009
118 Ft Monopole Tower Structural Analysis CC/BU No 875052
Project Number 2009184.47,Application 73650, Revision 2 Page 9
APPENDIX C
ADDITIONAL CALCULATIONS
RISATower Report-version 5.3.0.1
Square, Unstiffened Base Plate, Any Rod Material - Rev. F
Assumptions: Rod groups at corners. Total#rods divisible by 4. Ma)amum total#of rods=48.
Rod Spacing=Straight Center-to-Center distance between any(2)adjacent rods(same comer)
Site Data Reactions
BUM 875052 Moment ' 1526 ft-kips
Site Name: Associated Alarm System A)aal. -k ,w1'Sr .:kips
App#: 73650 Shear. F4 81 kips
Anchor Rod Data Anchor Rod Results
Qty 12,-` # Ma)amum Rod Tension: 131.4 Kips
Diam =2`25 .xin Allowable Tension: 195.0 Kips
Rod Material A615 J ` Anchor Rod Stress Ratio: 67.4% Pass
Grade(Fy) ' ° 7,5 y;:_ ksi
Bolt Circle f 46 i in PL Ref. Data
Anchors acin `,-1, W as: in I Base Plate Results Yield Line(in):
Base Plate Stress: 43.2 ksi 24.22
Plate Data Allowable Plate Stress: 55.0 ksi Max PL Length:
W=Side to :" 45` .:'=in Base Plate Stress Ratio: 78.6% Pass 1 24.22
Thick t 2 5 .:: in
Grade. -k-'AVf.55.n,__ ksi
B effective 24.22 in Max PL Length
Pole Data Yield Line
Anchors St 5t
Diam '39 42 :; in at corner= t= BASE PL
Thick 0 3125`; in Qty/4 THICKNESS
Grade 65`, . ksi
Anchor, Typ.
*4+
Stress Increase Factor
ASIF �1333'"
�G
i
L
9QF Pole w/
DIAM = D
Anchor
Spacing
Version 1.4, Effective May 8,2009 Analysis date: 5/15/2009
CAISSON Version 4.4.6 Fri May 15 10:03:08 2009
U.W. Short Course - 1998
*****************************************************************************
*
*
* PIER FOUNDATIONS ANALYSIS AND DESIGN - (C) 1995, POWER LINE SYSTEMS, INC.*
*
*
*** ANALYSIS IDENTIFICATION Associated Alarm System BU #: 875052
NOTES 2009184.47
*** PIER PROPERTIES CONCRETE STRENGTH (ksi) = 3.00 STEEL STRENGTH (ksi) = 60.00
DIAMETER (ft) = 6.000 DISTANCE FROM TOP OF PIER TO GROUND LEVEL (ft) = 0.50
*** SOIL PROPERTIES LAYER TYPE THICKNESS DEPTH AT TOP OF LAYER DENSITY CU KP PHI
(ft) (ft) (pcf) (psf) (degrees)
1 C 5.50 0.00 120.0 0.0
2 S 9.50 5.50 125.0 3.690 35.00
3 S 7.00 15.00 62.6 3.690 35.00
*** DESIGN (FACTORED) LOADS AT TOP OF PIER MOMENT (ft-k) = 2200.0 VERTICAL (k) = 15.0 SHEAR (k) = 25.0
ADDITIONAL SAFETY FACTOR AGAINST SOIL FAILURE = 1.54
*** CALCULATED PIER LENGTH (ft) = 19.500
*** CHECK OF SOILS PROPERTIES AND ULTIMATE RESISTING FORCES ALONG PIER
TYPE TOP OF LAYER BELOW TOP OF PIER THICKNESS DENSITY CU KP FORCE ARM
(ft) (ft) (pcf) (psf) (k) (ft)
C 0.50 - 5.50 120.0 0.0 0.00 3.25
S 6.00 8.54 125.0 3.690 677.30 10.91
S 14.54 0.96 125.0 3.690 -113.84 15.03
S 15.50 4.00 62.6 3.690 -524.14 17.54
*** SHEAR AND MOMENTS ALONG PIER
WITH THE ADDITIONAL SAFETY FACTOR WITHOUT ADDITIONAL SAFETY FACTOR
DISTANCE BELOW TOP OF PIER (ft) SHEAR (k) MOMENT (ft-k) SHEAR (k) MOMENT (ft-k)
0.00 39.3 3517.7 25.5 2284.2
1..95 39.3 3594.4 25.5 2334.0
3.90 39.3 3671.1 25.5 2383.8
5.85 39.3 3747.8 25.5 2433. 6
7.80 -53.0 3745.4 -34.4 2432.0
9.75 -183.5 3519. 9 -119.1 2285.7
11.70 -345.4' 3009.4 -224.3 1954.1
13. 65 -539.0 2152.1 -350.0 1397.5
15.60 -511.8 1018.6 -332.4 661.5
17.55 -263.8 259.8 -171.3 168.7
19.50 0.0 -0.0 . 0.0 -0.0
U.W. Short Course - 1998 Page 1/2
*** TOTAL REINFORCEMENT PCT = 0.48 REINFORCEMENT AREA (in^2) = 19.54
*** USABLE AXIAL CAP. (k) = 15.0 USABLE MOMENT CAP. (ft-k) = 2506.3 =
*** US Standard. Re-Bars (Select one of the following) :
98 BARS #4 (AREA = 0.20 in^2 DIA = 0.500 in) AT SPACING (in) = 1.99
64 BARS #5 (AREA = 0.31 in^2 DIA = 0.625 in) AT SPACING (in) = 3.04
45 BARS #6 (AREA = 0.44 in^2 DIA = 0.750 in) AT SPACING (in) = 4.33
33 BARS #7 (AREA = 0.60 in^2 DIA = 0.875 in) AT SPACING (in) = 5.90
25 BARS #8 (AREA = 0.79 in^2 DIA = 1.000 in) AT SPACING (in) = 7.79
20 BARS #9 (AREA = 1.00 in^2 DIA = 1.128 in) AT SPACING (in) = 9.74
16 BARS #10 (AREA = 1.27 in^2 DIA = 1.270 in) AT SPACING (in) = 12.17
13 BARS #11 (AREA = 1.56 in^2 DIA = 1.410 in) AT SPACING (in) = 14.98
9 BARS #14 (AREA = 2.25 in^2 DIA = 1.693 in) AT SPACING (in) = 21.64
*** PRESSURE UNDER CAISSON DUE TO DESIGN AXIAL LOAD (psf) = 530.5
U.W. Short Course - 1998 Page 2/2
Bk 24107 P9277 05?856
1 Q-21-200? ai 1 1 2 S3cx
RARNRABla
f61q.
D
'G9 SEP 30 P 3 .42
Town of Barnstable
Zoning Board of Appeals
Decision and Notice
Appeal No. 2009-058 - MetroPCS Massachusetts, LLC.
Modification Variance No's.2004-044&2000-031
To Allow Co-location of Communication Facilities on an Existing Tower
Summary: Granted with Conditions
Petitioner: MetroPCS Massachusetts, LLC
Property Address: 1047 Falmouth Rd., Hyannis,MA
Assessor's Map/Parcel: Map 250, Parcel 004
Zoning: Residential D-1 Zoning District
GP-Groundwater Protection Overlay District
Registry Reference: Original Variance-Book 13077, page 031
REID Corp Deed -Book 1399,page 183
Relief Requested and Background:
This application seeks to co-locate communication antennas on an existing monopole tower and to
add communication equipment within the fenced in area at the base of the tower. The applicant has
requested a modification of;the "parent bulk variance'Variance No. 2000-031, issued to Sprint
Spectrum, LP that provided for the replacement of a 115-foot lattice communication tower with a 120-
foot monopole tower and associated communication equipment, and the subsequent modification
Variance No. 2004-044 that allowed for the co-location of communication antennas and equipment of
Omnipoint Holdings, Inc.
The tower is located along Route 28 on property commonly referred to as the"Child's Building." The
locus is a 0.83-acre lot improved with a two-story office building of approximately 5,611 sq.ft.,and
the 120-foot monopole communication tower. A fenced in area of 33 by 21 feet contains related
communications equipment and a back-up electrical generator.
The use of the property for communications originated in 1975 as an accessory use to"Associated
Alarm Company". Later, in 1999,with the adoption of Article X- Personal Wireless Communication,
the use of property for communications was allowed as-of-right. In 2000, the Bulk Variance
authorized the tower replacement and in 2004,the modification allowed co-location. Today,
MetroPCS Massachusetts, LLC, seeks to further modify the existing variances to permit it to also co-
locate on the tower. The proposal is to install 3 flush mounted antennas at elevation 110 and to
enlarge the base equipment to house related ground equipment and a GPS antenna.
For standing,a June 2,2009 letter from Crown Castle USA Inc., the owner and operator of the
communication tower site, was submitted to the file authorizing MetroPCS Massachusetts, LLC.,to
seek the modification of the variances. In turn,an April 21, 2009 letter,with an approved signature of
Randolph E.Childs,Clerk of RELD Corporation who is the property owner,was submitted granting
permission to seek the modification. With respect to representation, a letter signed by Kate Rugman,
Site Acquisition Manager for MetroPCS Massachusetts, LLC., has authorized J. Lee Consulting Services
to make this application.
r
Bk 24107 Pg 278 #59856
Town of Barnstable,Zoning Board of Appeals—Decision and Notice
Appeal No.2009-058—Modification of Variance Nos.2000-031 and 2004-044—MetroPCS Massachusetts,LLC
Procedural &Hearing Summary:
This appeal was filed at the Town Clerk's office and at the office of the Zoning Board of Appeals on
August 17, 2009. A public hearing before the Zoning Board of Appeals was duly advertised and
notice sent to all abutters in accordance with MGL Chapter 40A. The hearing was opened September
16, 2009, at which time the Board found to grant the Modification of Variance Nos. 2000-031 and
2004-044. Board Members deciding this appeal were,James F.McGillen, Michael P. Hersey, Craig
G. Larson, George T.Zevitas, and Board Chair, Laura F. Shufelt,
At the hearing Mr.Gerry Squires, Real Estate Consultant with J. Lee Consulting Services, presented the
application before the Board. Also present was Brian Eicens, Radio Frequency Engineer for Metro PCS
New England Region. Mr. Squires presented the proposal and plans to co-locate on the tower. He
then provided the history of the permits for the tower.
Mr.Squires cited that MetroPCS is a limited liability company licensed in 2006 to provide personal
wireless communications. The company is now building-out its system on the Cape and this location
is ideal for the planned coverage in Barnstable.
Mr. Squires noted that the additional three antennas onto the tower would have little visual effect and
the added ground area for the equipment is to the back of the building and would not be visible from
Route 28. He noted the benefits of co-location and noted the height provides for a larger coverage.
Mr.Squires reviewed the prior findings of the Board when granting the rebuilding of the tower and
noted that the proposal today would have no detriment to the neighborhood than that which exists.
The Board and Mr. Squires reviewed proposed conditions. Mr. Squires agreed that MetroPCS would
abide by those proposed conditions.
Public comment was requested and no one spoke in favor or in opposition to the request.
Findings of Fact:
At the hearing of September 16, 2009,the Board unanimously made the following findings of fact:
1. Appeal No. 2009-058 is that of MetroPCS Massachusetts, LLC., as lessee, seeking a modification of
Variance No's. 2004-044 and 2000-031. The modification seeks to operate additional Personal
Wireless Communication on the existing communications tower and provide for the installation of
additional antennas and necessary ground equipment at the base of the tower. The property is
addressed 1047 Falmouth Road (Route 28), Hyannis, MA and is shown on Assessor's Map 250 as
parcel 004. The property is zoned Residential D-1 and is within a Groundwater Protection
Overlay District.
2. The application seeks to co-locate communication antennas on an existing monopole tower.and to
add communication equipment within the fenced in area at the base of the tower. The applicant
has addressed and satisfied all of the requirements for personal wireless facilities as set forth in
Section 240-107 of the Zoning Ordinance.
3. To allow MetroPCS to co-locate on the existing tower does not represent a substantial detriment to
the public good or the neighborhood affected. Based on an evaluation of the material submitted
and the evidence presented, the proposal fulfills the spirit and intent of the zoning ordinance.
2
. Bk 24107 Pg 279 #59856
Town of Barnstable,Zoning Board of Appeals—Decision and Notice
Appeal No.2009-058—Modification of Variance Nos.2000-031 and 2004-044—MetroPCS Massachusetts,LLC
Decision:
Based on the findings of fact,a motion was duly made and seconded to grant the modification of the
Variance Nos. 2004-044 and No. 2000-031 as requested by MetroPCS Massachusetts, LLC., for the co-
location and operation of communication facilities on the existing tower at 1047 Falmouth Road
(Route 28), Hyannis, MA subject to the following:
The installation and operation is limited to that of three flush mounted communication
antennas, including installation of associated ground equipment and a GPS antenna as shown
on plans submitted and approved by the Site Plan Review Committee entitled "metroPCS
Unlimit Yourself HYNO016A Crown 875052 Hyannis 1047 Falmouth Road Hyannis,
Massachusetts 02601 Barnstable County"consisting of 7 sheets as drawn by AEG Advanced
Engineering Group, P.C. last dated 8/5/09.
Condition 8 of the variances is changed to read:
8) There shall be no more than nine (9)antennas from Sprint Spectrum, LLP, two(2)whip
antennas, three (3) T-Mobile flush mounted antennas and three (3) MetroPCS flush
mounted antennas mounted to the Tower.
All other conditions of Variance No. 2000-031 shall remain in full effect and the following added
conditions imposed:
9) The location of any new concrete pad(s)shall maintain a 10-foot setback from all cesspools
and leeching fields.
The vote was as follows:
AYE: James F. McGillen, Michael P. Hersey, Craig G. Larson,George T.Zevitas, Laura F.Shufelt
NAY: None
Ordered:
Appeal No. 2009-058 has modified Variance No. 2000-031 and Modification Variance No.2004-044.
This decision must be recorded at the Barnstable Registry of Deeds for it to be in effect and notice of
that recording submitted to the Zoning Board of Appeals Office. The relief authorized by this decision
must be exercised within one year. Appeals of this decision, if any, shall be made pursuant to MGL
Chapter 40A,Section 17,within twenty (20)days after the date of the filing of this decision. A copy of
which must be filed in the office of the Barnstable Town Clerk.
MN
Laura F. Shufelt,Ch it Date Signed F �` Mti;i
I, Linda Hutchenrider, Clerk of the Town of Barnstable, Barnstable County, Ma eats : *y
certify that twenty (20) days have elapsed since the Zoning Board of Appeals fAhis :psi rd� 4
that no appeal of the decision has been filed in the office of the Town Clerk. % w
Z;r;�ap
Signed and sealed this day of 0( .t- /"N
der the pains '�jrd'�egalt sfVerjury' .`"
t ,b. ''.......•�•�o
Via
Linda Hutchenrider,Town Clerk
3
Bk 24107 Pg 280 #59856
Zoning Board of Appeals (ZBA) Abutter List for Mar
Parties of interest are those directly opposite subiel
abutters to abutters. Notification of all properties w
Map&Patcel Ownerl Owner2
249064 GIANNETTI, RUDOLPH V JR !
249066 RYAN,JOSEPH A& NATALIE TRS
249067 HEGARTY, MICHAEL J&MARIANNA
249068 ROSSEGALE, SAMILE ET AL
249069 JONES, DAVID T&SHEILA M
249070 MEDLIN, KAREN M
249071 MIRANDA, RUI A
249072 THOMAS,MURIEL %THOMAS, MURIEL ESTATE OF
249073 DUNN,KELLY P&WHITE, LUKE M
249077 HARDY,TERESA A&JOHN W
249153 FEDERAL NAIL MTG ASSOC %BEARD,ANDREW J
250001 FOUNDERS COURT CORP CIO C JOHNSON &CO
25000200A HOUSING ASSISTANCE CORP
25000200B HOUSING ASSISTANCE CORP
25000200C HOUSING ASSISTANCE CORP
25000200D HOUSING ASSISTANCE CORP
25000200E HOUSING ASSISTANCE CORP
2500020OF HOUSING ASSISTANCE CORP
2500020OG HOUSING ASSISTANCE CORP —
25000200H HOUSING ASSISTANCE CORP
250002001 HOUSING ASSISTANCE CORP -�
25000200J HOUSING ASSISTANCE CORP
25000200K HOUSING ASSISTANCE CORP
25000200L HOUSING ASSISTANCE CORP
25000200M HOUSING ASSISTANCE CORP
2500020ON HOUSING ASSISTANCE CORP
250003 BARCELOS,ALEX
250004 RELD CORP
250005 BOTSFORD, NORMAN L&JUDITH
25000600A FARDY,ALICE M
25000600E LAFTSIDIS,JOHN
250008 HAKALA,KENNETH A&FAITH S
250023X01 MELE, STEVEN A
250023X02 MELE, STEVEN A
250027X01 WEQUAQUET STRAWBERRY HILL LP C/O COFFMAN REALTY
250027X02 WEQUAQUET STRAWBERRY HILL LP C/O COFFMAN REALTY
250028 SCHOFIELD, BENTLEY C&DOROTHY G
250065 COREY, DONALD J JR
+ Bk 24107 Pg 281 #59856
& Parcel(s): '250004'
ct lot on any public or private street or way and
ithin 300 feet ring of the subiect lot.
Address1 Address 2 Mailing Cit StateZip Country Deed
718 STRAWBERRY HILL RD CENTERVILLE, MA 02632 14896/265
28 BLUEBERRY HILL RD HYANNIS,MA 02601 USA 10763/184
32 BLUEBERRY HILL ROAD HYANNIS,MA 02601 23114/269
42 BLUEBERRY HILL RD HYANNIS,MA 02601 21137/171
4 BLACKBERRY LN HYANNIS, MA 02601 USA 4188/284
56 BLUEBERRY HILL RD HYANNIS, MA 02601 USA 11396/164
64 BLUEBERRY HILL RD HYANNIS, MA 02601 15072/293
76 BLUEBERRY HILL RD HYANNIS, MA 02601 13199/195
82 BLUEBERRY HILL RD HYANNIS, MA 02601 USA 187021298
59 BLUEBERRY HILL RD HYANNIS, MA 02601 21271/75
69 BLUEBERRY HILL RD HYANNIS, MA 02601 USA 22965/133
PO BOX 1100 CENTERVILLE, MA 02632 USA 9366/118
460 W MAIN ST HYANNIS,MA 02601 USA 18026/201
460 W MAIN ST HYANNIS,MA 02601 USA 18026/201
460 W MAIN ST HYANNIS, MA 02601 USA 18026/201
460 W MAIN ST HYANNIS, MA 02601 USA 18026/201
460 W MAIN ST HYANNIS,MA 02601 USA 180261201
460 W MAIN ST HYANNIS, MA 02601 USA 18026/201
460 W MAIN ST HYANNIS, MA 02601 USA 18026/201
460 W MAIN ST HYANNIS, MA 02601 USA 18026/201
460 W MAIN ST HYANNIS,MA 02601 USA 18026/201
460 W MAIN ST HYANNIS,MA 02601 USA 18026/201
460 W MAIN ST HYANNIS, MA 02601 USA 18026/201
460 W MAIN ST HYANNIS, MA 02601 USA 18026/201
460 W MAIN ST HYANNIS,MA 02601 USA 18026/201
460 W MAIN ST HYANNIS, MA 02601 USA 18026/20/
2 BLACKBERRY LN HYANNIS, MA 02601 21599/277
1047 FALMOUTH RD HYANNIS, MA 02601 USA 1399/183
1069'FALMOUTH RD HYANNIS, MA 02601 USA 1368/380
6 KENSINGTON DR SANDWICH, MA 02563 21298/92
1087 FALMOUTH ROAD CENTERVILLE, MA 02632 21814/278
728 STRAWBERRY HL RD CENTERVILLE, MA 02632 USA 2893/242
P O BOX 956 CENTERVILLE, MA 02632 USA 17960/329
56 LAKEVIEW DR CENTERVILLE,MA 02632 USA 17960/329
1300 BELMONT ST-SUITE 302 BROCKTON,MA 02301 17960/323
1300 BELMONT ST-SUITE 302 BROCKTON,MA 02301 17960/323
PO BOX 44 HYANNIS, MA 02601 21602/215
1 TINKERS LEDGE RD DUXBURY,MA 02332 JUSA 19570/086
I
a
Bk 24107 Pg 282 #59856
T OWN OKBARNSTABLEZON1II BOARDOFAPPEALS,
NOTICE OF PUBLIC HEAWNO UNDER
To.all persojunterested in,:or,affected by the•Zonlrig Boapl of,
Appeeq;under Section ll,of Chapter 40A of the Cieheral.lsws'of.
the Commomvealth of MassadrtOetts,and ali amendmenisthereto
you are here6�notified that:
,y
7:00 PM•`•Appeal,ko._206IIU4
StrreeneylMlddlaiy.-:•' '.`: .
Karen I.MullalySweeney and Michael.Sweeney have.applied.:..
cil Sectiort.Special Permifpursuairt to 240.92(B)N&sl:r toYming.
But•IdingsorShuauresusedasSinglea'ndTwaFamrlyrResidErices�= .
and.Sec6 240-94(Bj.Exoai lion ot`a,Nonporlformin Use;.:The-_
appfcarttsareseeldngreliefIni derioaftersMeiipandthee"lig
nonconforming two-family use by;cortatnio0ng a newcottaga tcl
rear of the property and to comrert ttre eicisfing'coltage sUydu re etto
a gatage.:The property s"addressed 4364 Falmouth;Road(Route
28),Cotuit,_MA`H la shdm o i Assessor s Mep 024 ag peioe)625
and is zoned Resider=F
7:00 PO Appeat No.2609458
M WPC9:Massach'usettg;LLC.: :,; '',:,i•`:'
:.MetroPCSMaseacfrusetb,LLC,aslessee,hasappli¢dtura'modN'.
ficationbfVadinooNo's.2004-044arrd2000-031.Tfiemodficetion.;
seeks tb'operate additional Personal 4Yreless Comrmgilcati6rre on
the ezisi0g eommunicatiorn:,tower.arrd:prb4Jde forMI Installation..
of addi¢pnal antennas and riecessary.'76urid',ei{iip-rd ai the
base ot6..tower,The propeNis addressed.1047 Falmouth Road
(Route`28),Nyanids"MA and is sho ".!Assessors lN.ap 25U as
parce1004;:Tile_propertyJa zoned-Residential Ei 1'and" xrth(n a,
GroomlwaterProtechonAvedayDistrict:;��>='..?:�.;: ::. .
These Public Hearcrgs wal be field at ihe'Bamstalile,To*h Hal
367MWnStieei,Hyanhis,MA,HeadngRaoin,2""f;loor,Wedneaday;
September 16,2009."Plans and appQcationspdr i.be reviewed`at
the Zoning Board of Appeals Office,GrouYNi Nlanageril Depal
ment,Town Offices;200 Main Skeet Flyaruiis�iRA
•• _ 'taura.F;Shu(eI�.CFia'u:':
.v. :..Zoning Board;bmni is
The Bamsfabie Patriot a :
August H and September 4,20Iffili
� .
STABLE COUNTY
REGISTRY OF DEEDS
Iv
A`I RUE COPY,ATTEST
Ilk
,F.'AifEADE,GREGISTER
BARNSTABLE REGISTRY OF DEEDS
r
�.a
+w Fa
3530 Toringdo Way
Suite 300
Charlotte, NC 28277
April 21,2009
i
Reid Corporation
1047 Falmouth Road
Hyannis,MA 02601
RE:Tower"ASSOCIATED ALARM SYSTEM-875052"
To Whom It May Concern:
As you know,Crown Castle is the owner and/or operator of the communications tower site referenced above. A core
component of Crown Castle's business is the co-location of wireless telecommunications service providers to our existing
tower assets. It is our strong belief that co-location benefits all parties involved,including Crown Castle,the service
provider,the neighboring community,and you—our valued landowner.
In some instances,Crown Castle's agreements with our landowners require us to obtain consent from the landowner prior to
co-locating telecommunications providers. Over the past number of years,our customers have placed increasing importance
on"speed to market"or the length of time it takes to co-locate on one of our towers. More than any other factor,
telecommunication providers have identified speed to market as their most crucial issue. Unnecessary delays and long wait
times can,and have,caused customers to abandon projects and/or switch to other locations,costing Crown Castle and .
ultimately you in lost revenues.
In an effort to reduce that wait time,Crown Castle has taken steps to identify the points in the process that create
unnecessary delays. Obtaining consent is one of those points,and we'd like to enlist your help in eliminating this delay.
We are asking that you sign where indicated below,hereby granting consent to Crown Castle for future co-locations,
construction drawings,and/or modifications of equipment and any other consent requirements within Crown Castle's lease
area.
It remains Crown Castle's priority to communicate with you regarding the tower site and its activities. Additionally,you
will still be entitled to any and all additional revenue owed under the lease for these co-locations and other projects. In fact,
by granting consca,t now for these future projects,y ou will be hcl&ig to spew up our co-location Xufts,thereby allowing
for us to pay you your additional rent sooner.
If you agree to our request,please indicate so by signing on the line below. Please sign both copies,retain one copy and
return the other to me in the self-addressed stamped envelope provided. If you have any questions regarding this request;
please contact me using my contact information listed below.
Sincerely,
Kathy Boc2o
Project Coordinator
Phone:704-405-6563
Email:Kathy.boczko@crowncastle.com
APPROVED BY: DATE: 6
Daytime telephone: S"O 8`- 7:73= 91/1/
Email Address: T'Chi/�S e0
f Jr
v
CRO w'Y Crown Castle Tel: 704 406.6600
CASTL E 3530 Toringdon Way,Suite 300
' Charlotte,NC 28277 www.cmwncastle.com
Friday May 8,2009
Reld Corporation
1047 Falmouth Road
Hyannis,MA 02601
RE: Consent to Sublease
For Property at: 1047 Falmouth
Crown BU#875052
Carrier:MetroPCS
Dear Sirs;
MetroPCS has requested permission to place antennas on the tower and
equipment on the ground,within our leased area.Pursuant to Section la of the Rider to
the PCS Agreement we are requesting said consent.Also, Sec lb states,that you are
entitled to receive a 30%revenue share for this sublease.
This letter grants MetroPCS permission to apply for any permits required for this
installation.
Would you please countersign this letter below to acknowledge your consent and
fax a copy to me at 724 416-6971 or email me at paul.hughey@crowncastle.com. Please
also return one copy with your original signature in the enclosed self-addressed,stamped
envelope. If you have any questions or comments,or if you need additional information,
please do not hesitate to contact me at(704)405-6571.
Sincerely,
Paul Hughey
Approved By: Date