Loading...
HomeMy WebLinkAbout0015 GEORGE STREET l S �.��e �}- ; TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Map CA Parcel 6 Application # S d Health Division Date Issued Conservation Division Application Fee r' Planning Dept. Permit Fee V Date Definitive Plan Approved by Planning Board Historic - OKH_ �_ Preservation / Hyannis AIS Project Street Address Village Owner r Address Telephone ` c a(v_o Permit Request b Sb wL z­v�c 6P Lu Square feet: 1 st floor: existing " proposed 2nd floor: existing proposed Total new Zoning District Flood Plain Groundwater Overlay Project Valuational. Construction Type 9'3 Lot Size Grandfathered: ❑Yes J6No If yes, attach supporting documentation. Dwelling Type: Single Family Two Family ❑ Multi-Family(# units) Age of Existing Structure �5' Historic House: ❑Yes allo On Old King's Highway: ❑Yes ONO Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑ Other Basement Finished Area (sq.ft.) _ Basement Unfinished Area (sq.ft) Number of Baths: Full: existing new Half: existing new Number of Bedrooms: existing _new ,,Total Room Count (not including baths): existing new First Floor Room Count ;Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑ Other 'Central Air: ❑Yes ❑ No Fireplaces: Existi4o-- New Existing wood/coal stove: ❑Yes ❑ No Detached garage: ❑ existing ❑ new siz ool: ❑ existing ❑ new sizA�Barn: ❑ existing ❑ new size Attached garage: ❑ existing ❑ new sizShed: ❑ existing ❑ new sizAt Other: Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Y a1 '�iq Commercial ❑Yes ONO If yes, site plan review# Current Use� Proposed Use C�C_ APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Nam • ��(� 6ry)df/i ' A d In elep hone Number 5� Address 1 L' ✓ License # ` i 6R6 S _v1V1�5 Ud(o(o d Home Improvement Contractor# Email 0. 4 e4A�_ Worker's Compensation # 1 a o2 ALL CO RUCTION DEBRIS RESULTI &IFROM THIS PROJECT WIL E TAKEN TO l \ SIGNATURE DATE 1 FOR OFFICIAL USE ONLY APPLICATION# } DATE ISSUED MAP/PARCELNO. k ADDRESS VILLAGE OWNER DATE OF INSPECTION: FOUNDATION FRAME INSULATION FIREPLACE ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH FINAL GAS: ROUGH FINAL a' FINAL BUILDING DATE CLOSED OUT ASSOCIATION PLAN NO. 1 WIMP ! iI1M�b Zoe cr � A �d IJ� 0 DocuSign Envelope ID:89583321-2763.4E55-9539-1BE34837420C Llt" SolarCity I Solarlease .t AMENDMENT ,M Customer Name and Address Installation Location Date James Michie 15 George St 11/6/2015 HYANNIS,MA 02601 15 George St Barnstable,MA 02601 1. The Solarlease Agreement between SolarCity and You,(the"Agreement")including the Summary and Exhibits to that Agreement,are hereby amended as follows: a. The rate you pay us will never increase by more than 2.90%per year. b. We estimate that your System's first year production will be 6,704 kWh. c. Section 3 of the Agreement,"System Description"is replaced in its entirety with the following: Lease and installation of a 7.830 kW DC photovoltaic system consisting of PV modules,corresponding inverter(s) and a mounting system designed for installation and operation at your Home. d. Section 4 of the Agreement,"Lease Payments;Amounts" is replaced in its entirety with the following: 3055 Clearview Way,San Mateo,CA 94402 888.765.2489 solarcity.com Solarlease Amendment,version 2.1.0,June 25,2015 Contractor License MA HIC 168572/EL-1136MR a a Document generated on 10/31/2015 1268065 ❑ ■ DocuSign Envelope ID:89583321-2763-4E55-9539-1BE34837420C __ ---- - -- - ---- --------------------- ---- ----- -- -- --- -- -- ------- - ]] :f A. Amounts Due at Lease Signing,Installation and Building B. Monthly Payments: Inspection: Your first monthly payment is$69.83, Payments Due at Signing: followed by 11 monthly payments of$69.83 each, Amount Due at Lease Signing: $0.00 followed by 12 monthly payments of$71.86 each, Delivery/Installation Fee: $0.00 followed by 12 monthly payments of$73.94 each, Total Due at Lease Signing: $0.00 followed by 12 monthly payments of$76.08 each, followed by 12 monthly payments of$78.29 each, Payments Due at Installation: $0.00 followed by 12 monthly payments of$80.56 each, followed by 12 monthly payments of$82.90 each, Payments Due after Building Inspection: $0.00 followed by 12 monthly payments of$85.30 each, followed by 12 monthly payments of$87.77 each, followed by 12 monthly payments of$90.32 each, followed by 12 monthly payments of$92.94 each, followed by 12 monthly payments of$95.64 each, followed by 12 monthly payments of$98.41 each, followed by 12 monthly payments of$101.26 each, followed by 12 monthly payments of$104.20 each, followed by 12 monthly payments of$107.22 each, followed by 12 monthly payments of$110.33 each, followed by 12 monthly payments of$113.53 each, followed by 12 monthly payments of$116.82 each, followed by 12 monthly payments of$120.21 each. Your total lease payments,excluding tax,are$22,288.92. Your estimated average monthly tax payments are$0.00. Your first Monthly Payment is due on the first day of the first full calendar month following the Interconnection Date. After your first Monthly Payment,future Monthly Payments (and any applicable taxes)are due on the first day of the calendar month. SolarLease Amendment,version 2.1.0,June 25,2015 1268065 oa a DocuSign Envelope ID:89583321-2763r4E55-9539-1BE34837420C ti C. Other Charges: D. Total of Payments(A+B+C):$22,288.92 This is the total amount you will have paid by the end of this If you make your Monthly Payments by allowing us to I Lease. It includes the Monthly Payments stated above and automatically debit your checking or savings account,then f estimated taxes of$0.00. you will receive a discount of$7.50 on your.Monthly Payments.The Monthly Payments listed above reflect this discount. If you do not allow the automatic debit,this f discount will not be applied to your Monthly Payments and I !� each Monthly Payment will be$7.50 greater. i I E. Purchase Option At End of Lease Term: F. Other Important Terms: f I You do not have an option to purchase the System at the end See Section 2 above for additional information on the Lease of the Lease Term. i Term and also see below for additional information on termination,purchase options, renewal options, i I maintenance responsibilities,warranties, late and default charges and prohibition on assignment without SolarCity's i consent. Payments due upon installation are due immediately prior to commencement of installation. i e. The last sentence of Section 5(f)is replaced in its entirety with the following: The total estimated amount you will pay for taxes over the Lease Term is$0.00. SolarLease Amendment,version 2.1.0,June 25,2015 1268065 go INA@1 DocuSign Envelope ID:8958 3321-2763-4E55-9539-1 BE34837420C r c f. The last sentence of Section 5(h)is replaced in its entirety with the following: You agree that the System is not a fixture,but SolarCity has the right to file any UCC-1 financing statement or fixture filing that confirms its interest in the System. g. Section 5 of the Agreement,"Lease Obligations"is amended to include the following: (k) You authorize SolarCity„or its designee,to obtain your credit report now and in the future,check your credit and employment history,answer questions others may ask regarding your credit and share your credit information with SolarCity's financing partners.You certify that all information you provide to us in connection with checking your credit will be true and understand that this information must be updated upon request if your financial condition changes h. Section 12(a)of the Agreement is hereby replaced in its entirety with the following: (i) Transfer this Lease and the Monthly Payments. The person buying your.Home(the"Home Buyer")can sign a transfer agreement assuming all of your rights and obligations under this Agreement by qualifying in one of three ways: 1) The Home Buyer has a FICO score of 650 or greater; 2) The Home Buyer is paying cash for your Home;or 3) If the Home Buyer does not qualify under(1)or(2),the Home Buyer qualifies for a mortgage to purchase your Home and either you or the Home Buyer pays us a$250 credit exception fee. (i i) Move the System to Your New Home. If you are moving to a new home in the same utility district,then where permitted by the local utility,the System can be moved to your new home pursuant to the Limited Warranty.You will need to pay all costs associated with relocating the System,execute and provide the same access and ownership rights as provided for in.this Lease and provide any third party consents or releases required by SolarCity in connection with the substitute premises. (iii) Prepay this Lease and Transfer only the Use of the System. At any time during the Lease Term,if the person buying your home does not meet SolarCity's credit requirements, but still wants the System,then you can(A) prepay the payments remaining on the Lease (See Section 16(i)(i)and(ii)),(B)add the cost of the Lease to the price of your home;and(C)have the person buying your Home sign a transfer agreement to assume your rights and non-Monthly Payment obligations under this Lease.The System stays at your Home,the person buying your Home.does not make any Monthly Payments and has only to comply with the non-Monthly Payment portions of this Lease. i. Section 12(b)is replaced in its entirety with the following: You agree to give SolarCity at least fifteen(15)days but not more than three(3)months' prior written notice if you want someone to assume your Lease obligations. In connection with this assumption,you,your approved buyer and SolarCity shall execute a written transfer of this Lease. Unless we have released you from your obligations in writing,you are still responsible for performing under this Lease.If your buyer defaults on this Lease and we have not yet signed the transfer agreement,you will be responsible for their default. We will release you from your obligations under this Lease in writing once we have a signed transfer agreement with the person buying your Home(provided such person has been approved as a transferee by SolarCity in writing). SolarLease Amendment,version 2.1.0,June 25,2015 1268065 DocuSign Envelope ID:89583321-2763-4E55-9539-1BE34837420C ` a v 2. Exhibit 2 of the Agreement,the Limited Warranty,is hereby amended as follows: a. The Table of Guaranteed Annual kWh in Section 2(b)(i)is replaced in its entirety with the following: Year Guaranteed kWh Total kWh Guaranteed PremjkWh 2 12,705 12,705 0.12927 4 12,578 25,284 0.13826 6 12,453 37,737 0.14787 8 12,329 50,065 0.15815 10 12,206 62,271 0.16914 12 12,084 74,355 0.18089 14 11,963 86,318 0.19347 16 11,844 98,163 0.20692 18 .11,726 109,889 0.22130 20 11,609 121,498 0.23668 b. The second and third sentences of Section 2(b)(i)A are replaced in their entirety with the following: Your cumulative Actual kWh is dependent on a shading percentage of 28.00%on your Home. If this shading percentage increases,your Guaranteed Actual kWh will be reduced proportionately. SolarLease Amendment,version 2.1.0,June 25,2015 1268065 ats o o d. DocuSign Envelope ID:89583321-2763-4E55-9539-1BE34837420C I have read this Amendment in its entirety and I acknowledge that I have received a complete copy of this Amendment.This amendment supersedes any prior amendments that are inconsistent with the subject matter contained herein. The pricing in this Lease Amendment is valid for 30 days after 10/31/2015. If you don't sign this Lease Amendment and return it to us on or prior to 30 days after 10/31/2015,SolarCity reserves the right to reject this Lease Amendment unless you agree to our then current pricing. Customer's Name:James Michie SolarLease A Dmuftned by:. Signature: ,awtt,S SolarCity Date: 11/6/2015 approved Customer's Name: Signature: Signature: Lyndon Rive, CEO Date: Date: 10/31/2015 A SolarLease Amendment,version 2.1.0,June 25,2015 1268065 as RIM 4 Q c A� w a .. �? lr,<� (� ��� 1xjs2crlc�trl�/�r� 0- - 1� �; 1cic�6r, �:� /l1 Office of Consumer Affairs d Business Regulation k�l 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement.Contractor Registration Registration: 168572 Type: Supplement Card SOLAR CITY CORPORATION 1w Expiration: 3/812017 CHERYL GRUENSTERN -- 24 ST MARTIN STREET BLD 2UNIT 11 MARLBOROUGH, MA 01752 _ -. _ ---_-.-.- --.------ _-- Update Address and return card.Mark reason for change. sc cs zo _ Address Renewal i, ? Employment �_'' Lost Card °�. /fn`f'r��rr��r�rt�•.•�.r//i ra'/fl. ni.7.�rc;a/L; r =Office of Consumer Affairs&Business Regulation License or registration valid for individul use only OME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation i Registration: 168572 Type: 10 Park Plaza-Suite 5170 Ex P�iration: 3/8/2017 Supplement Card Boston,MA 02116 SOLAR CITY CORPORATION 1 J CHERYL GRUENSTERN 3055 CLEARVIEW WAY - � r SAN MATEO,CA 94402 I valid Undersecretary .. Not valid without signature Tito Commonweatlth of Manwkuwft Department of IndustrPaJAcciderit I Congress Street,Suite mo Boston,Mt!62114--2017 www.mass gav1ft Workers'Compensation Insurance AlrWmit:Builders/Contractors/Electricians/Plumbem TO BE FILED WITH THE PIZIMITf INN AUTHORITY. Aggscantinformation Please Print I.e>ziltty- N t1iB(13usinc s/�rt;asizalien/tndi�idu�rl): 80[arCity Corporation Address: 3055 Ctesarvlew Way City/Staie/Zip: San Mateo,CA 94402 phone#: (888)765-2489 Am you sm cmplmyer?Check the appropriate box: Type of project(required): 1.141 am aettWol ,8r wah 15,000 employers(fall md1bTpWUi1=).• .7. []New construction 2.[]1 an a sole pmmietor or partaersGip end have no employees worl:irg for me in S. []Remodeling any capacity.INo Morkes'comp.huoininm recln'med.j s.[ji am a luarieown«daingall work mysctC.[Nuworkers'camp•iusurartcertxlnlrctiJ f 4• ❑Demolition �[]i am a humcowner mid win behiring etmtractors to coadoct aid trait m my propcny. i will 10 ]Building addition am=that all awwwm oidw have xrorkm.,coinpunsation insuraw orare sole I I.❑Electrical mpairs or additions proprietors wM no employem 12.Q Plumbing repairs or additions 5.01 mn a wnaml.cmuraetor and I have hired dne sub-conbutors listed on eke atinched S>rEet. I3.[]Roof repairs These n&=�have employees and have workers'comp.imsruame i i4.❑f Otharsalarpant:is We arc a oupwAim and its officers have esemisat their right of examinee per MOL C. G.Q 152,§t(41 turd we have no employees,[No workers't rnnp.insurance repkd.J *Any appti=9 dW ch b box ti Most uiso Gil out tlic section below shiawing dreir workers'compeuutim policy infomation. t I IontoWnWvt Artbtoir this anti wit indicating they are doing all work rend then We ontside..conWtors meat submit a dery affidavit indicating such tCowmtlom tt>at chcei this hoc trea.-d auacted an additional sheet showing the==of the sub-eouraam and me whether or nil titose'Whies have aToloya s. if the tutb-moots bt►ve cmpW cs.they most providc their wdrt«s'comp policy mm 6a. 1 ant apt enmloyer that is providing workers'Compensation insurance for my empk ms. Below is the pa/icy and jab site inforo►t. Insurance Compmy Name.American Zurich insurance Company Policy#or Self ins.Lic.4: WC0182015-00 Expiration Date: 9/1/2016 15 George Street Hyannis,MA 02601 Job Site Address: city/stata%ip: Attach a copy of ttte workers'corrtpensatiou poky declaration page(skewing the policy allerebcr NO expiration date). Failure to fie:coverage as required under MOL c.152,§25A is a criminal violation punishable by a fine up io S 1,500.00 and/or one-year imprisonment,as well as civil penalties in the form ofe STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office oflnvestigations of the DIA for insurance Coverage Verification. I do kereby cerVIV under the pains and penalties of perjury that the Utformallon provided above is True surd correct. (Jason Pair November 19,2015 ! Ph • O,,Qiciai use only. Do not write in this area,to be completed icy they or town officiaL City or Town: iPernAt/License# Reeving Apthoritp(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.gleetrical Inspector S.Plumbing Inspector 6.Other Contact Person: Phone& • AC R1J� DAM(MMODNYM ` CO CERTIFICATE 4F LIABILITY INSURANCE W1712016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN T14E ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT.: If the certificate holder is an ADDITIONAL INSURE%the pohey(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain Policies may require an endomement. A statement on this certif Cato does not confer rights tothe certificate holder in lieu of such endorsement(s). PRODUCER - CONTACT MARSH RISK&INSURANCE SERVICES —_—..._..._...._......_...... ._..._... . ......... . . .....__ _..._.._T_._ 346 CALIFORNIA STREET,SUITE 1300 PHONE 66� CALIFORNIA LICENSE NO.0437153 ADD RNO SAN FRANCISCO,CA 94104 AOPREs. .......... .._....--..------..._..-- Aft ShwwSw11415.743-8334 _._....... _...........iNsuRER(s)aFFORawacovE ►e ..... - ------ iaucif 998301-STND-GMVUE-15-16 MURER A:Zwich American lnswame Campmy 116535 Sda[C4 Corporation INSURER l;;NIA NIA 3055 Clewhaw Way msuRFJt C:NA _ _ ........_. 'fA _ .._ .___ Bari Mateo,CA 94402' INSURER D:American Afth Insi farm Company 4- �0142 INSURERE:..__....__._. HISUR9L F COVERAGES CERTIFICATE NUMBER.- SEA-DD271363M REVISION NUMBER:4 THIS 1S TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLANS. ...T.... .. ......___--- -----._.... i 'IN _..-TYKE OF INSURANCESURR PdUCY NUS POLICYEFF PPOOUCD E" L@rFSLTR iA X COMMERCIAL GENERAL LIABILITY GLO0182i116-00 l0112015 091D112016 EACH OCCURRENCE S 3.000,0D0 TO RENTED F —j CLAIMS MADE n OCCUR IEpAGE M$E$1EQ S 3.ODD:000 F X ISIR S250,OOD f MED'W Vnl nspessonl.:- S.... 5,0EI0 PERSONAL&ADY INJURY GEH•L AGGREGATE LIMIT APPLIES PER I GENERAL AGGREGATE S 6�• X POLICY LOC PRODUCTS-COMPIOP AGG S 6,000,000 PRO- JECT . ._ i OTHER. S A AUTOMORILELALNLITY ; IBAPMBZn7--00 09IOtY�15 09/Q1r1D16 COAABlIdED SINGLE LrdTF S X ANY AUTO I BODILY IMAJRY(Per person) S ALL OWNED X_ SCHEDULED AUTOS X AUTO BODILY INJURY{Par accident) 5 x HRED AUTOS rx. ANUTTt 1 IIANED I PROPERTY eG6.......... $. COMPICOLL DED: S $5,000 .._. tRNBRELJALfAO ! 1 EACH OCCURRENCE S_..:_...._... - EXCESSLU/B CLAIMS-MADE - I ` AGGREGATE S OED RETENTIONS S D WMERS COMPENSATION ; jwC0162014-W(A0S) 0901015 1091D1rM16 x I PER T AND EMPLOYERS•LIASILITY - - - --- A ANY PROPArrORIPARTNERIEXECUTIVE Y f N WC0182015-00(hIA) 09@1rt015 '09,D112016 E.L.EACHAIX�DENT S 1,o00,0D0 OFfIt"WEM9EREXCWDED? �RIA{ —._ _....._ ............. (Mandatory In NH) WC DEDUCTIBLE:�.� E L.DISEASE-EA EMPLOYEE S 1,000,0b0 Mdescribe under RIPTIONOFOPERATIONS betow E.L DISEASE-POL WIT S ( DESMPTWN OF OPERATIONS/LOCATIONS I VO*C1£S IACORD ref,Ad0brud Reraarke ScheNrie,may he atfaehod If move Spam Is raquhedl , EvMpICCOfhlSwdnlS;. � CERTIFICATE HOLDER CANCELLATION Sdar(Ay Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055CtmvtowWay THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo.CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Charles Mamiolel0r- 01988.2014 ACORD CORPORATION. All rights reserved. ACORD 26(2014101) The ACORD name and logo are registered marks of ACORD Version#52.6-TBD -'IQ Zi4 p=, SOlarQty. October 28, 2015140REDGE JP. RE: CERTIFICATION LETTER S 5000! Project/Job#0262182 Project Address: Michie Residence 15 George St Barnstable, MA 02601 yyL. Design Criteria: -Applicable Codes= MA Res.Code, 8th Edition,ASCE 7-05, and 2005 NDS - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground Snow Load = 30 psf - MP1: Roof DL= 11 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL = 21 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.18757 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above.based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. This review relies*on the roof's structural system having been originally designed and constructed in accordance with the building code requirements and having been maintained to be in good condition. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural review is provided in the results summary tables on the following page. Digitally signed by William A.Eldredge Jr. Date:2015.10.28 William A. Eldredge, P.E. 18:19:56-04'00' Professional Engineer T: 888.765.2489 x58636 email: weldredge@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com A2 ROC 243771,CA 0SL8 88810C CO EC8041,CT IHIC 003277g.DC HIC 71101488.OC I•IIS 71101488,HI C7 29770,MA HIC IM72,MD MHIC 128940..NJ 13VH08180600. . . OR CG8 1&0445,PA 077343,TK TDLR 27000.WA QCLt SOLARC'91997.9 2013 SolsrO ty.All rights reserved. Version#52.6-TBD „SolarCit Y HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES � Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi 64" 24" 39" NA Staggered 61.7% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi 48" 20" 65" NA Staggered 77.2% Structure Mo nting Plane Framing_ _ Qualification Results Type Spacing Pitch Member Evaluation Results MPi Stick Frame @ 16 in.O.C. 250 Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ R00 243771,CA C&.8 888104,CO EC 8041,CT HIC 0632778,DC HIC 71101486,DC HIS 71101488.HI CT•29770,MA HIC 108672,MO MH1C 128948,NJ 13VIi06160000, OR 008 180400.PA 077343,Tx TDLR 27006,WA GCLt.SORARC"A1907.O 2013 Soleroty.All rights refoNed. ti �p STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP1 Member Properties Summary MPi Horizontal Member Spans Rafter Pro erties Overhang 0.74 ft Actual W 1.50" Roof System Properties -Span 1 12.63 ft Actual D 5.50" Number of Spans(w/o Overhang) 1 San 2 Nominal Yes A :^Roofn Material CompRoo San 3 2' Re-Roof No Span 4 S. 7.56 in.A3 PI oad Sheathing _ No "S an 5` '' " I c;,; w 20.80 in:A4 Board Sheathing Solid-Sheathing Total Rake Span 14.75 ft TL.Defl'n Limit 120 Vaulted Ceiling 't �, No xP c;: PV 1°Start 3.92 ft 4 =m .Wood Species SPF- Ceiling Finish 1/2"Gypsum Board PV 1 End 1175 ft Wood Grade #2 Rafter Slope $, 251- r .•.PV 2 Start _n x . ,. ..Fbr 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top tat Bracing Full- t :v PV 3 Start v' E 1400000 psi Bot Lat Bracing At Supports PV 3 End Emi„ 510000 psi - Member Loading mary Roof Pitch 6 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 11.0 psf x 1.10 12.1 psf 12.1 psf PV Dead Load PV-DL3:0psf `' `xFi:10 }' � . t '° - 33 psf Roof Live Load RLL 20.0 psf x 0.93 18.5 psf p x UP IEx 0.7- 21:0 psf, �4e �. 21.0 psfe Live/Snow Load `�' � `LL SLi'��"� ''� a *�30.0` •sf�' Total Load(Governing LC TL 33.1 psf 36.4 sf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf= 0.7(CO(CO(IJ pg; Ce 0.9,Ct=1.1, IS=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CF Cr D+ S 1.15 1.00 0.53 1.3 1.15 mber Analysis Results Summary Governing Analysis I Max Demand @ Location CapacitV DCR Result Bending + Stress 1507 psi 7.1 ft 1504 psi 1.00 Pass CALCULATIONLOF-DESIGN�WIND LOADSW 40-1 " Mounting Plane Information Roofing Material Comp Roof PV System Type' ` a "`'� "° SolarCity SleekMountT" .-_- Spanning Vents No Standoff Attachment Hardware �3, .4, v 7 77 7, 77 . Comp'MountType C, a e a# Roof Slope 250 Rafter_Spacing Framing Type j Direction Y-Y Rafters Purlin Spacing 'T '01 — °, (_- Purl ns,Only�` �. .�. _, _ NA Tile Reveal Tile Roofs Only NA Tile Attachment System: Tle Roofs Only # _ •* � ° NA <_ ' Standin Seam ra S acin SM Seam Onl NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Desi n Methodsh —•6 "� ._,___9__ .____ "' ;'Partially/Fully�Enclosed Method r- Basic Wind-Speed V 110 mph e - Exposure Category 3. � ,Ri 4u �� � �< G }� �_ -— Fig 6 1 Section 6 6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mea Roof Height' h 15 ft Section 6.2 _. Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic_Fact or -_„ ._ , rt .x. wW 1.00 ,,; A Ao Section 6.5.7_-- Wind Directionality Factor Kd 0.85 Table 6-4 Im ortance'Factof I 1.0 Table 6-1 Velocity Pressure qh qh 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 22.4 psf Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-11B/C/D-14A/B W. Pressure Coefficient` Down "' GC DOW - 0.45 . ,,. . :. .: _ ;. Fig.6-11B/C/D-14A/B Design Wind Pressure p p= qh(GC) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down 10.1 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacings Landscape 64" 39" Max Allowable Cantileve[A Landscape _ _ r 24 - -NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area, ,_ _Trib 17 sf ,r . PV Assembly Dead Load W-PV 3.0 psf Net Wind'Uplift`at Standoff '- T-Tctual _"` _ -_ _'_-309'lbs Uplift Capacity of Standoff T-allow 500 Ibs Standoff,Demand/Capacity .. DCR. t :i _ 4 61.7% t, r ;ar , 7 .� t. 4. ., . X-Direction Y-Direction Max Allowable Standoff-Spacing Portrait 48" 65" Max Allowable Cantilevers i Portrait- 20 " — --- �-, NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib � „�,� � . 22 sf"-; � • PV Assembly Dead Load W-PV 3.0 psf Net Wind,Uplift'at Standoff f T-actual ry -386 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff,Demand/Capacity DCR ,;: 7v � - 7,777, 7,577.2% ;: ,,oF lati Town of Barnstable *Permit#� ( / ( Expires 6 m onths from issue date BAMSM11M ; Regulatory Services MA Fee �a3 y SS. g Thomas F.Geiler,Director QED MA't Building Division Tom Perry, Building Commissioner , X-PRESS PERMIT. 200 Main Street; Hyannis,MA 026Q 1 )ffice: 508-8624038 _ OCT 16 2002 iax: 508-790-6230 EXPRESS PERNUT APPLICATION - RESIDENTIAL TOWN OF BAR(1fSTABLE Not Valid without Red X-Press Imprint /parcel Number 4 q erty Address S7— .esidential Value of Work_ p��0, 00 er's Name&Address //' N/,?/VA ractor's N Telephone Number e Improvement Contractor License#(if applicable) truction Supervisor's License#(if applicable) orkman's Compensation Insurance Check one: ❑ I am a sole proprietor Q.jAffla the Homeowner I have Worker's Compensation Insurance nce Company Name f//2 f �° INS. C-1) ZEE IKZ nan's Comp.Policy#_ U"I`i 3Z57 too g � __` 'Request(check box) ❑ Re-roof(stripping old shingles) All construction debris will be taken to '- �, e-roof(not stripping. Going over � existing layers of roof) ❑ Re-side ❑ Replacement Windows. U-Value (maximum.44) ❑ Other(specify) *Where required: Issuance of this permi not exempt compliance with other town department regulations,i.e.Historic,Conservation,etc. re exnmtra t , G- + ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA •A z AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO .UPS. CONIC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, r - j •" FSB FIRE SET-BACK A SIGN WILL BE PROVIDED.WARNING OF THE 4� GALV GALVANIZED HAZARDS PER ART. 690.17 . a GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY - HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. i CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL , Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR + kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. . . NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE, OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. ' �= PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY ° V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 PROPERTY PLAN 4 . IV3 ELEVATION IV4 SATELLITE RENDERING LICENSE GENERAL NOTES PV5 RENPV6 SITE PLAN SITE PLAN - PV7 STRUCTURAL VIEWS S L F GEN 168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION # OF THE MA STATE BUILDING CODE. `: .,. :• PV8 THREE LINE DIAGRAM ELEC 1136 MR 2. ALL ELECTRICAL WORK SHALL COMPLY WITH Cutsheets Attached THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR REV BY DATE COMMENTS AHJ: Barnstable +1 4 REV A NAME DATE COMMENTS ,'.. UTILITY: NSTAR Electric (Cambridge Electric Light) x x x x CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-0262182 00 , CONTAINED SHALL NOT BE USED FOR THE MICHIE, JAMES MICHIE RESIDENCE Rob Kreis BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: •�O'SolarCit NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C ',1�5-GEORGE ST n{'. 7.83 KW PV ARRAY h� yi ; PART TO OTHERS OUTSIDE THE RECIPIENTS p ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES n BARNSTABLE, MA 02601 TMK OWNER: Ma��D��;Bwldmg 2'Unitlt' THE SALE AND USE OF THE RESPECTIVE (29) AU Optronics # PM060MOO-27OW SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER:- PAGE NAME: SHEET: REV DATE 7 (650)63Morlborou 01752 636=1029. y PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A-USOOOSNR2 508 790-4757 PV 1 10 28 2015 c- ( ) COVER SHEET / / (B88}(650)6 8-10282469) wwrs9-10 9, 1 - 1 ' 15 George St(E)DRIVEWAY i Front Of House i �F O , 1 F, . i 1 IillliIL111 III illlll ! , II ' Illll IL l llll ' 1 -� -� - -I- 1 1 ' Illi � lll � l � illll III IIIIIIIIiIIIIIIIIIIi , C I 93 ' IIIIIIIIIIIIIIII 1113 IIIIIII III I III I Iv . . . Ili . . . . 1 � IIII ! ! ! Illllillllllll �clllllllllitllllllll t � I - ' 1 1 , 1 - I I , PROPERTY PLAN N Scale:I" = 20'-0' W E 0 20' 40' S CON J B-0 2 6 218 2 00 PREMISE OWNER. DESCRIPTION: DESIGN:. CONFIDENTIALAL— THE INFORMATION JOB NUMBER:CONTAINED SHALL NOT BE USED FOR THE MICHIE, JAMES MICHIE RESIDENCE Rob Kreis :;,S��a�C��ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Aro NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15 GEORGE ST 7.83 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: BARNSTABLE, MA 02601 THE SALE AND USE OF THE RESPECTIVE (29) AU Optronics # PM060MOO_27OW e24 St. Martin Drive,Bud 01752 ding 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN NVERTER PAGE NAME' REV. DATE- T. (650)638-1028 A F: (650)636-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE6000A-USOOOSNR2 (508) 790-4757 PROPERTY PLAN PV 2 . 10/28/2015 (888)—SOL-CITY(765-2469) www.gdarcitY�n n PROPOSED ARRAY T.O. BUILDING - _ T. ARR Y DOOR DOOR WINDOW . WINDOW WINDOW WINDOW DECK REAR EL'EVATI ON scnil 1/4._1,0. PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-0 2 6 218 2 00 h%' CONTAINED SHALL NOT BE USED FOR THE MICHIE, JAMES MICHIE RESIDENCE Rob KreiS —:,;SOIa ��t BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �a- NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15 GEORGE ST 7.83 KW PV ARRAY a r� PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: BARNSTABLE MA 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH r - THE SALE AND USE OF THE RESPECTIVE 29 AU tics PM060MOO_27OW 24 St.Martin Drive,Building 2,Unit 11 [INVERTER:SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ER: p 0ron PAGE NAME: SHEET: REV: DATE: Marlborough,MA 01752, T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. 508 790-4757 '4' . PV 3 10 28 2015 ) _ r� SOLAREDGE SE6000A—USOOOSNR2 � � ELEVATION- ' / / (BeB)—sa—CITY(7ss=24ela r�wNsolarony.a«p r, a t' t: r � a . � r . a � J r- s r l:. s PA fPpt6*w* g' J B-0262182 0 0 PREMISE OWNER DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: _ ��\f CONTAINED SHALL NOT BE USED FOR THE MICHIE, JAMES MICHIE RESIDENCE Rob Kreis �ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15 GEORGE ST 7.83 KW PV ARRAY ,;SOlarC� PART TO OTHERS OUTSIDE THE RECIPIENTS NODDLES BARNSTABLE, MA 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (29) AU Optronics # PM060M00-27OW SKEET: REV DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME' T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER' 508 790-4757 PV 4 10 28 2015 (BBB)—SOL—CITY(765-2489) www.solarcity.com -------------- so�ARE�cE sEs000A—us000sNR2 SATELLITE RENDERING / / r b r; 1 PREMISE OWNER DESCRIPTION: DESIGN: e CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: J B-0 2 6 218 2 00 it CONTAINED SHALL NOT BE USED FOR THE MICHIE, JAMES MICHIE RESIDENCE Rob KreisBENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .��c SOlarC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15 GEORGE ST 7.83 KW PV ARRAY ���., Y• PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES BARNSTABLLE, MA 02601 THE SALE AND USE OF THE RESPECTIVE (29) AU Optronics # PM060M00_27OW 24 St. Martin Drive, Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: ` T• (650)638—t028 F, (650)6381029 SOEAREDGE SE6000A—USOOOSNR2 (508)•790-4757 - RENDERING PV 5 10/28/2015 (e66)-SOL 1 (765-24e9) ,.meola.aRy.aa�n STAMPED & SIGNED PITCH: 25 ARRAY PITCH:25 FAR STRUCTURAL ONLY MP1 AZIMUTH: 175 ARRAY AZIMUTH: 175 tt�o+` MATERIAL: Comp Shingle. STORY: 1 Story Digitally signed by VALLIAMA. William A.Eldredge Jr. SMMUME,Ap, 15 George S t Date:2015.10.28 18:20:32-04'00' lit Front Of House Ilk (E) DRIVEWAY LEGEND (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS Y AC Q DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS . �n V O DEDICATED PV SYSTEM METER M P 1 Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR GATE/FENCE A Q HEAT PRODUCING VENTS ARE RED r._ I. `I INTERIOR EQUIPMENT IS DASHED L_�J SITE PLAN N Scale: 1/8" = V w E 0 1' 8' 16' S J B-0 2 6 218 2 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: SolarCity. CONTAINED SHALL NOT BE USED FOR THE MICHIE, JAMES MICHIE RESIDENCE Rob Kreis �1BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15 GEORGE ST 7.83 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS NODDLES BARNSTABLE MA 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (29) AU Optronics # PM060MOO_27OW PAGE NAME SHEET: REV: DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T.- (650)638-1028 R (650)638-1029 PERMIS51ON OF SOLARCITY INC. SOLAREDGE SE6000A—USOOOSNR2 (508) 790-4757 SITE PLAN PV 6 10/28/2015 (888)-SOL—CITY(765-2489) www.solarcity.com PV MODULE S 1 5/16" BOLT WITH LOCK r INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND.DRILL.PILOT ARRAY SKIRT ZEP RRA .(6) HOLE. • -, r (4) (2) ` SEAL PILOT HOLE WITH '• • �. POLYURETHANE SEALANT., s . ,ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) LBW ` (E) COMP. SHINGLE (4) PLACE MOUNT. (1) SIDE VIEW O F. M P 1 NTS (E) ROOF DECKING U (2) (5) INSTALL LAG BOLT WITH A 5/16" DIA STAINLESS (5) SEALING WASHER. i STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES F INSTALL LEVELING FOOT WITH MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES WITH SEALING WASHER C(6)r BOLT & WASHERS. LANDSCAPE 64" 24" STAGGERED - (2-1/2" EMBED, MIN) PORTRAIT 48" 20„ (E) RAFTER STANDOFF ROOF AZI 175 PITCH 25 RAFTER 2X6 @ 16 OC ARRAY AZI 175 PITCH 25 STORIES: 1 S C 2x6 @16" OC Comp Shingle Scale: 1 1/2 .J. 1 o OF �fJ Wllf"A ,. STAMPED & SIGNED FOR STRUCTURAL,;ONLY CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-0262182 00 CONTAINED SHALL NOT BE USED FOR THE MICHIE, DAMES t MICHIE RESIDENCE Rob SHALL KreisSO�afC�ty ' BENEFIT OF ANYONE EXCEPT SOLARCIIY INC., MOUNTING SYSTEM: - •- - -- - -- - --- - - �..�„ ' NOR ALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15 GEORGE ST '. 7.83 'KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES:- BARNSTABLE MA 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE 29 AU 0 tronics # PM060MOO-27OW 24,SL Martin Drive,Building 2;Unit 11, SOLARCIIY EQUIPMENT, WITHOUT THE WRITTEN ( ) p tt SHEET: REV: DAIS: Marlborough,MA 01752 + PAGE NAME PERMISSION OF SOLARCITY INC. INVERTER: T: (650)638-1028, F. (650)638-1029 SOLAREDGE SE600oA—USOOOSNR2 (508)„790-.4757 STRUCTURAL VIEWS PV 7 1o/2s/2o15 (8BB)-SOL-CITY(785-2489) www:4olareltycom, 4 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:B10 202OCT Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE#SE6000A-USOOOSNR� LABEL: A -.(29)AU 0�pptronics # PM060M00-27OW GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:2303629 Tie-In: Supply Side Connection Inverter; 60 0W, 240V, 97.5�� w Unifed Disco and ZB,RGM,AFCI PV Kdule; OW, 243.1 PTC, MC4, 40mm,BlackonBlack, ZEP, 1000V, 50P F. ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 38.5 Vpmox: 31.8 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 100A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING BRYANT CUTLER-HAMMER JIG_ Load Center100A/2P 4 Disconnect 3 SOLAREDGE Dc+SE6000A-USOOOSNR2 DC ------MP 1�1x15 35A/2P gzaov ------------- ----------- C -----M� A Li r-------- I B L2 DC+ I I N DC- I 2 (E) L0ADS - ---- GND ------------------------- - GEC ---TN DC C+ MP 1: 1x14 I - G z I GND -- EC-'C--- --------------------- tJ N I (1)Conduit Kit; 3/4' EMT -_j c EGC/GEC_ .• - _ ' • z its I GEG TO 120/240V i T SINGLE PHASE UTILITY SERVICE I I I I . I I ' I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (2)Gro,d R. Q (1)BRYANT#BR24L7ORP PV (29)SOLAREDGE 300-2NA4AZS 5r8 x 8, �per ^ Load Center, 70A, 120/24OV, NEMA 311 AC PowerBox (Sptimizer, 300W, H4, DC to DC, ZEP DC -(2)ILSCO y PC 4 (4- -(I)CUTLER-HAMM $BR235 n� Insulation Piercing Connector; Main 4/0-4, Tap 6-14 Breaker, 35A2P, 2 Spaces (1)AWG�6, Solid Bare Copper S SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE B (1)CUTLER-HAMMER g DG222URB -(1)Ground Rod; 5/8' x 8% Copper AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R. N ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION N0. 2, ADDITIONAL - -tI A(1)CUTLER AMMER Ground eutral it;DC10ONB ( )6D-100A, General Duty(DG) ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 1 AWG#6, THWN-2, Black 1 AWG g8, THWN-2, Black 2)AWG #10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC cn 4 (1)AWG#6, THWN-2, Red 3 (1)AWG#8, THWN-2, Red 1 (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=11.42 ADC- - 1 AWG P _ P_ O�( ) � P P- ( ) �6,.THNM-2, White NEUTRAL Vm -240 VAC Im -25 AAC 1 AWG 0, THWN-2, White NEUTRAL Vm -240 VAC Im 25 AAC . . . , , , , . (1)Conduit KIt; 3/4` EMT . . , . , -(1)AN#6,_Solid Bare.Copper. GEC, (1)Conduit.Kit;.3/4'.EMT. . . . . . . . . . . . . . . . .-(1)AWG 8,.THMI47?,.Green . . EGC/GEC. 0 Conduit,Kit..3/4',EMT. . . . . . . _ . . (Y)AWG #10, PV Wire, 600V, Black Voc =500 VDC Isc =15 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.66 ADC (1)Conduit Kit; 3/4' EMT . . . . . . . . . . . . . . . . . . . . .. . . .. . . . . . . . . . . . . J B-0262182 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER:CONTAINED SHALL NOT BE USED FOR THE MICHIE, JAMES MICHIE RESIDENCE Rob Kreis � ,;SO�a�C■�ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: •�� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15 GEORGE ST 7.83 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: BARNSTABLE, MA 02601 ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE (29) AU Optronics # PM060MOO-27OW 2a st.Martbi Marlboroougug,Buildingh,MA 0175 2 Unit 11 PAGE NAME SHEET: REV: DATE 2 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: L• (650)638-1028 F: (650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE6000A-USOOOSNR2 (508) 790-4757 THREE LINE DIAGRAM PV 8 10/28/2015 (6B8)-sa-CITY(765-2489) www.solarcity.com • e o o •o e - Label Location: Label Location: Label Location: (C)(CB) (AC)(POI) o (DC)(INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 loo o rZOA NEC 690.17.E M o o e o- o NEC 690.35(F) Label Location: - o 0 0 •- TO BE USED WHEN (DC) (INV) o•jp o• -o o -o s o ' ,o INVERTER IS D O Per Code: ; UNGROUNDED s f a NEC 690.14.C.2 Label Location: Label Location: - o 0 o e. .° o oCp (POI) -o (DC) (INV) ° Per Code: -O Per Code: •-e oo e e NEC 690.17.4; NEC 690.54 .O e NEC 690.53flyArlwaky ° o to o•s le - 1 Ci^ISl • e al °- e' Label Location: to ( (DC) (INV) Per Code: 690.5(C) Label Location: (POI) -e e o • e o Per Code: •t NEC 690.64.B.4 F :z..-. Label Location: o (DC)(CB) -Boma Per Code: Label Location: - o NEC 690.17(4) (D) (POI) ° o' Per Code: e•o s •• . - - e 'o a p� o��- -o o - ®:• a NEC690.64.B.4 0 0 1• 0 oe •- -e s o - • Label Location: o (POI) _ Per Code: F Label Location: ow— e oNEC 690,64.B.7(AC) POI o (AC): AC Disconnect dG ( ) -- D O Per Code: ° - r (C): Conduit NEC 690.14.C.2 F (CB): Combiner Box (D): Distribution Panel w. ' (DC): DC Disconnect ' (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect (AC) (POI) ; (LC): Load Center to -oil kar �A. Per Code: a NEC 690.54 (M): Utility Meter (POI): Point of Interconnection a CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED 3055 Clearview Way San Mateo,CA 94402, IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set 'o.''a►` T050)638-1028,;F:(650)638-1029 EXCEPT IN CONNECTION IWTH THE SALE AND USE OF THE RESPECTIVE SO a�' (888)SOL-CIIY(765-2489)www,solarcity.corn SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. Q +;, YI ®p I ® ii,SoiarCit Ze Solar Next-Level PV Mounting Technology '�-SolarCity Zep Solar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs '�-'--r..Up-roof. . V , Ground Zep sh_.)Interlock (xoy sift - ��,_•,�_ Lereline Foot Zep campatibfe PV klodule _ •„r Roof Att�diment . Array Skirl QGOMp4T/ �e�F Description h i r W PV mounting solution for composition shingle roofs i �pCGMpp'00v Works with all Zep Compatible Modules - • Auto bonding UL-listed hardware creates structual and electrical bond J • Zep System has a UL 1703 Class"A"Fire Rating when installed using V� LISTED modules from any manufacturer certified as"Type 1"or"Type 2" Comp Mount Interlock Leveling Foot Part No.850-1382 Part No.850-1388 Part No.850-1397 Listed to UL 2582& Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 Designed for pitched roofs s ';R[o Installs in portrait and landscape orientations t • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards i • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72' and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices j Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 1 of 2 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 io solar=oo solar=oo SolarEdge Power Optimizer t�f1 Module Add-On for North America ^ �pV P300 / P350 / P400 SolarEdge Power Optimizer r C� P300 P350. P400 } Module Add-On For North America (for 60-cell PV (for 72-cell PV (for 96-celI PV modules) modules) modules) - � ..- . - P300 / P350 / P400 INPUT Rated Input piC?over° 3D0 4DD W 0 Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc MPPT Operating Range.........................:...............................8.:48.....................8:.60.....................8..80......... ...Vdc..... Maximum Short Grcurt Curren[(Isc) Adc Maximum DC Input Current ........................ ... ...,..,....I....... 12.5 .. Adc ' ': r Maximum Effiaency 99.5 Y v. Weighted Efficiency 98.8 ........ .....% Overvoltage Category II . .OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) 6. .. M..axi.mu....Ou.tput..Curr...en.[ ........................................15 ... .... ....m ...P... ...........................I.. .......... .......................... .... Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) •— Safety Output Voltage per Power Optimizer 1 Vdc •.� ,r`a` ::r 3 STANDARD COMPLIANCE,! - t(B,�aN��•�",-''t�' " ' EMC FCC Part15 Class B,IEC61000 6.2,IEC61000 6 3 afety....I................ ..... .. ....................l.lcla fetY),UL1741................... ............. ... .. ..... • '' _ - S IEC62309 ss II sa - ROHS Yes » )INSTALLATION SPECIFICATIONS ,�% '.i Maximum Allowed System Voltage .................1000.., Vdc Dimensions.(W. _..... ,...,. 141x 212z40.5/S.SSz834x159 mm/m ....... .. ... ... .......................... ;,p - `. Welght hncludmg cables)..... .. 950/2.1 ................... gr/lb.... . - Input Connector ...........................MC4/Amphenol/.Tyco Wir T Connector Double Insulated Am henol -Output e YPe/C .... ............................I..... ... ... .. .. - Output Wire.Length.... .. ... ............. ....... .....0.95./3.0... 1.2/,3.9 m/h .. ...... ............................................................... ... .....I.......................... ................. .... .. ..... Operating Temperature Range ....... ;40 +85/40 +185 .. .............................. .. .. ' * %f ' '..a.. Protection Rating IP65/.NEMA4 - ,: - ...... .................................. ................'..... .. .. ....... ............... ... .......................... ............. ...... 0 300................................... .. % , ....................................................... ........ ..... - xaree src no..c.onna mo6 c mosaic of up ro sz 'PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V - PV power optimization at the module-level Minimum String Length(Power Optimizers) 8 10 18 — Up to 25%more energy - - - Max mum Stang length(Power Optimizers) ... .25. ...,. .... 25 „,,, ,,,,. 50 , .. ................................................. .5 Maximum Power per String 5250 6000 12750 -s w —Superior efficiency(99.5%) ` - .......................... .......................... ............. ........... ........... .. I ...... - •' � � � � Parallel Strings of Different Lengths or Orientations Yes - Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading ''""""""'" "" """""""" "'""'"'"''' "'"""' """'"".." "" .... — Flexible system design for maximum space utiliiation I �. - Fast installation with a single bolt - Next generation maintenance with module-level monitoring - Module-level voltage shutdown for installer and firefighter safety , USA - GERMANY - ITALY.- FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us - _ »,.uT*•r5`}�, MM. R:Rs MUMS., - GreenTriplex PM060M00 (260 - 270Wp) GreenTriplex Electrical Data Dimensions mm[inch] PM060MOO Typ.Nominal Power PN 260% 265 27.W p ontview 483 aigntwew -}{- 40 Typ.Module Efficiency 16.1% 16.4% 168% (3e.70) I I [I 571 Typ.Nominal Voltage Vmp M 30.8 31.3 31.8 Typ.Nominal Current Imp(A) 8.45 8.48 8.50 Mono-Crystalline Typ.Open CircuitVoltageVoc M 38.0 38.2 38.5 - - - __ - Photovoltaic Module ` � Typ.ShorcGircuitCurrentisc(A) 8.96 8.98 9.01 - .. 39 Maximum Tolerance of PN 0/+3% (64.52) .... tar_.!+ �•� + .,�*7'"' 'yam�' -� -�•- •Above data are the effective measurement at Standard Test Conditions(STC) �.r �. +n.�"" ww- .,ra,�"'•' - •STG rradi nce I000 W/m',speccrzl dutnbution AM I S•Temperature 25 t 2'C,in accordance wnh EN 60904-3 r �:i i ++'� aaf� n'T� .'^+ w:a. _ •The given electnaI data are nominal values which account for basic measurements and manufacturing tolerances of t.IM with the . .f` • - « ,u ,,.,s O Power Range exception of N.The classifications is performed according co N `'*ya'R s P,�,-ems w►. „�+�• +T. _ - 260--270 Wp •27OW modules will be available from Q2 2014 Temperature Coefficient NOCT. 46 t 2°C v _ •m ,�.r^+ *'r Typ Temperature Coefficient of PN -0.44%/K Highly Strengthened Design ,= . - - - -- _ _- W star view [928 mp Typ Teerature Coefficient of Voc -0.30%/K ; Module complies with advanced loading tests to - _;: . - _ (Dis n betw°en two Mounting H°les) ___ meet 2400 Pa loading requirements - Temperature Coefficient of Isc 0.06%/K 11 5 g 9 _ 329 e ]unction 13ox [0451 yh,,*Lr.'*4'*"'�'�•' •NOC.Normal Operation Celli peactme. asuring conditions:irradiance 800 W/m',AM 1.5.air temperature 20°C.wind speed l m/s [I2-911 40 f' • "+a Mechanical Characteristics p.s71 q� �.,,'.`w+."�`+ IP-67 Rated Junction Box �► Dimensions(L x W x H) 1639 x 983 x 40 mm(64.53 x 38.70 x 1.57 in) L ,yy,. Advanced water and dust proof level1200 35 I Weight 19.Skg(43 Ibs) [47.241 [I.3e1Front Glass Hi h trans arent solar ass tem ered 3.2 min 0.13 in 983*Fij g P g1 (tempered),), ( ) [35.701 a�-�+ � �}�� - ••�, Cell 60 monocrystalline solar cells,156 x 156 min(6"x 6') .. Integrated Racking Solution Cell Encapsulation EVA y ~ !; Mol Simplifies installation process and reduces labor l4desx4 cost Back Sheet Composite film(Black) (-) (�) Frame Anodized aluminum frame(Black) t yi4 F wf' i Junction Box IP V rated with 3�bypass diodc3dir I Connector Type&Cables I MC KST4/KBT4:1 x 4 mm'(0.04'x 0.16 in'),Length:each 1.2 m.(47.24 in)r GHolesnx4g I-V Curve IN curve s d,ff.irradiance PV CYCLE op- Operating9 Conditions A Operating Temperature fi -40 +85°C 4 0 _ oo-w m AmblentTerriperature Ranged -40 +45°C a bo Boow/m' +: a• +k '` i'7,�r „ Max.System Voltage UL C600V s 5.0 _,. _ .0 500 W/m' Serial Fuse Rating 15 A 1 3.0400 Winn, Maximum Surface Load Capacity Tested up to 2400'Pa according to UL 1703 2.0 } 200' y'XM44r `Y -!'ice _ Warranties and Certifications 0.0 0 5 10 Is 20 2S 30 35 40 {M^ Product Warranty Maximum 10 years for material and workmanship voltage M * :*' -'" j+• +` t '_ "' = '' - `--' "` '"'-"` Current/voltage characteristics w irradiance and dependence on irradian and module temperature. * 4 r •°�'" )°r r Performance Guarantee Guaranteed output of 90%for 10 years and 80%for 25 years ! Certifications According to UL 1703 guidelines,Fire Rating Type 2.2 r-•' 'r '2:Please confirm other ce detail rtifications wiith official dealer - ' *� Packing configuration .'•-h f -rwa 'e Container 20'GP 40'GP 40'HQ • r+ t Pieces per pallet 26 26 26 Pallet per container 6 14 28 ,•• Pieces per container 156 364 728 Dealer Stamp AU Optronics Corporation No.I,Li-Hsin Rd.2.Hsinchu Science Park,Hsinchu 30078,Taiwan s 'y BenQ Tel:+886-3-500-8899 E-mail:BenQSolar@auo.com www.BenQSolarcom Ben So I air BenQ Solar is a division of AU Optronics This datashaet is primed with soy Ink Solar ®Copyright May 2013 AU opvor.ics Cory.A0 Hgho reserved.Information may charge widwut notice. i t - =oo Single Phase Inveilers for North America solarsoIar o oSE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE1000OA-US/SE1140OA-US • - SE3000A-US SE380OA-US SE5000A-US SE6000A-US SE760OA-US SE10000A-US SE11400A-US I OUTPUT p Q 9980 @ 208y S o I a I Edge Single Phase Inverters � 'p C + .Nominal AC Power Output 3000 3800 5000 6000 7600 10000-@240V 11400 VA • . 1 ................ .....r 5400 @ 208V 10800 @ 208V 1^ North I r}h America ��1 A r• Max.AC Power Output 3300 4150 5450.e.?40V. 6000 8350 10950.�n 240y• 12000 VA For 1 V o 1 LI 1 A 1 1 G 1 i ca AC Output Voltage Min.-Nom.Max." (. ..183-208 229 Vac - - SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ Output Vol-....Min...-...Max.... .......:...:.... ................................,:.............. ...:...:...................:...... .................. ........... AC Output Voltage Min:Nom:Max!'I � v/ SE760OA-US/SE10000A-US/SE1140OA-US 211-240-264Vac - AC Frequency Min.Nom;Max.tlt.---.•• ,•••-,••„•••,•• ..- ..,-•••••59.3 60-60.5(with Hf country setting.57-60-60.5)„•-•-..•••••,-•••..•,•,.•••-- ••Hz•••- r;--, 48 @ 208V - Max Continuous Output Current •-••12:5--••-•I• --- 16 ..---L-21@240V-•••.••--25- - I.-----32•••••. 47.5 A .......42 .240V... ............................. _,.. GFDI Threshold 1 .... ...........................A..... Utility Monitoring Islanding Protection,Country Configurable Thresholds -Yes Yes . ... t .:. 'INPUT "-•s'�werte�'•�< Maximum DC Power(STC) 4050 5100 6750 8100 10250 - 13500 15350 gy W m`�n-qG oe.} Transfo mer less Ungrou............ ....................................................... Yes ......... ..................... ........ ... .... ... Max. r nded Input Voltage 500 Vdc a Waeta�ty; ; - - - _ •�!a7»•�e�„N u\/0°'-1 ..N..m-.DC.I.n ut..Volta .................. ................I..•••..•---....I165@325@208V/3.50-@ I24.0V-- I I V..d.c .o.. .. . ... g 20 I •�-...- . .- -•--- @ .•••-••••--.-- ��-..... -...-.. Max.Input Current(2) 9.5 1 18 23 34.5 Adt 305 .......... V.. ..................... ........................................... ................ ....... 15 � ......... ......... . - ' Max nut Short Circuit Cu 45 Reverse-Polarity.Protection Yes ,- ........................ .................................................. .......................................................... -. Ground Fault Isolation Detection 600ka Sensitivity .............ion. e.t..ti........ ........... ••••--.minverter Efficiency••••-.•- ...97:7. .98.2-•. 98.3- •..98.3•• ....98 98 ......... •..-98 /o.••., mu ..._-._... •`.; .:,, . .- " rt. }... C Weighted Efficiency... 97.5 98 .....I.998 @•40y........97.5..... .....97.5.... ..9775-(a12240V..1......97.5...........%..... M CE _ ADDITIONALighttime ow rConsu Eption....... <2.5 1 Supported Communication Inte rfeces R5485,RS232,Ethernet,ZigBee(optional) ........................................... ............. ........ ....... .............-..................................... ......... 1 1 - ' -- • ' Revenue Grade Data,AN51 C12.1 Optional' .. .. ........................................... ..................................................................................................................................... — ge rapid shutdown kit is installed(Ol „ 35TANDARD COMPLIANCE i • enabled when SolarEd _ en UL1741 UL3699B UL1998 CSA 22 2....... ......... ................ ......... 0 12 Functionality Grid Connection Standards.......... ............................ .........................IEEE1547.... .. ............................... ........... ...... .-...... ...... ........................................ ........ FCC Emissions ° INSTALLATION SPECIFICATIONS • - • AC output conduit size/AWG range 3/4 mlrnmum/16 6 AWG art 3/4 minimum/8 3 AWG - .• ::. - ..IjC... .. ......... ... .. ...... ............. I input conduit size/p of strings/ 3/4"minimum/1-2 strings/16-6 AWG 3/4"minimum/1-2 strings/ nd ni • , ' AWG ran e....... ..... .................... ............................ ...................... ... 14:6 AWG .... .. - .. a r .�, w --.......g. .. .. ..... .. ' t ..-.. i �. �,. a .. ,: t f s�' Dimensions with Safety Switch - -30.5 x 12.5 x 10.5-% -•in/ - 30.Sx12.5x7.2/775x315x 184 ..Wxwxp) ............. ..-.. ..... ...775 x 315 x 260 -mm• Weight with Safety Switch............. ..........51.2/?3:?..........L.................•54.7/24.7.. .. ..........884/401.......... ...16/.kg... .... ... ..... ... ... . ..Natural.. ... .... .. convection _ Cooling - Natural Convection and internal Fans(user replaceable) fan(user - ..• The best choice for SolarEd a enabled systems replaceable)-- oQ V ................................... ...................................................... ................................................ b 1 oise ..25 ......<S0 N , d.. Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance , Min:Max.Operating Temperature 13 to+140/ 25 to+60(-40 to+60 version avallablelsl) -F/'C Superior efficiency(98%) Range-.--.......•. - Protection Rating NEMA 3R - Small,lightweight and easy to install on provided bracket a For other regional settings please contact SolarEdge support. RI A higher current source may be used,the inverter will limit is input current to the values stated - _ Built-in module-level monitoring - pl Revenue gradeinverter SEx A-USOOONNR2(for 760OW Inverter:6E7600A-US002NNR2). 14l Rapid shutdown kit P/N:SE1003-RSD-Sl. Internet Connection through Ethernet or Wireless Rl 40 version P/N:SEx A-USDDONNU4(for760OW inverter:6E7600A-US002NNU4). - Outdoor and indoor installation . , r .. . Fixed voltage inverter,DC/ACconversion only Pre-assembled Safety Switch for faster installation } ,t 1 Optional—revenue grade data,ANSI C12.1 sunsc�E�c � 0� — ----- — -- - — —_ —— — w __ —tp 4J�1►J USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THENETHERLANDS-ISRAE'L WWW,SOlaredge.US ) Moe