Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0959 BEARSE'S WAY - Health (2)
�W' AN10, C" It vt W� Z;�,O rM r-kog", ON 11, MAI 11 0 ill�` j 4qm V tm, Ag OF g 17 44� g tf lal WP `�K _1P, , , v_e k IL I llk�, k- 6, l,!s; M`P ."'2 V 7 rw 14 dO 4, e'P mwl&&`1111��,M War., _W; s 4�1'�5 _KV APF �_,Ex ino % fF I A�,N�z��%,Rp�',Vi kl,?rof,q1`0 s4i L V_NPI l4 4- 2 .00 01 I Wx 959 BEARSES WAY , HYANNIS , MA 02601 i6l I L List Of Drawings Cover Sheet Sheet A- 6 Bar Layout I"% Floor F ing Plan & Building Section Sheet A. 1 Front & Right Elevation Sheet SA ram Sheet A. 2 Rear & Left Elevation Sheet S . 2 Roof Framing Plan Sheet A- 3 Floor Plan Sheet E - 1 Main Floor Electrical Plan Sheet A. 3 - 1 Floor Plan w/ Nightclub Sheet E . 2 Basement Electrical Plan Sheet A.4 Basement Plan Sheet FS- 1 Food Service Equipment Layout nint chedule Sheet A. 5 Interior Elevations Sheet FS-2 Food Service Equipme S SITE ENGINEER: STRUCTURAL ENGINEERING: DESIGNER: INTERIOR DESIGNER: PHILBROOK ENGINEERING NORTH SIDE BUILDING CONSULTANTS BELLE INTERIORS, LLC DOWN CAPE ENGINEERING, INC. T Varnum Philbrook, P. E. Gary A. Ellis Elaine Bellefeuille 939 Main Street 107 Beach Street 141 Main Street 17 Derby Lane Yarmouth Port, MA 02675 Dennis , MA 02638 Yarmouth Port, MA 02675 Harwich, MA 02645 508-385-8682 508-362 -9802 508-280-7031 508 362 -4541 I ti Y U Q m H z = z O r w WU � Q aC1 O wQ = co w o aWoQ z z 0Y © � = W z Z> z U w � z2z mmtL- � z w < 0C u. O oo oo co ao co r r r r r fA Imo- 00 w M t�Dt� � O O O O O -1 r Ln 4-1 oaoo FIRST FLOOR (SUB FLR) RAMP EA L ct3 NORTHEAST J -Q-12 ) FRO w UiN NT ELEVATION LA �. co v • 'ca N ry C) m L- 00 t� z >- Ln o m a w z C7 u� w a PROPOSED ATTIC ACCESS AT CABLE END tV 'Q X, ILI Lffl-u flT Z Z FIRST FLOOR (SUB FLR) H J �Qr �O .�+ co SOW z NORTHWEST u c RIGHT ELEVATION 0 I- W Q Z m > o W an w CL w r U w di cr F= ,o i-- DATE: 02/20/18 SCALE: 1/4"= 1'-0" DRAWING#: I U Z_ Z O O FD N W � mm cn W ¢ bU 0 CL Q z Z C) off = W Z 2 Z U W � Z *s Z PROPOSED -i m �? ATTIC ACCESS W Q W 2-EXHAUST VENT AT GABLE END Z x F- V a u- O m oo co co co i wcfl to W o Nv- v- v- t� o 0000 -LL H —LULLU FIRST FLOOR (SUB FLR) _ _ T _ i v V) SOUTHEAST �1 LEFT ELEVATION W i i N 4 00 L1Cm � Om Q � � , r- 1- 00 uz U') co W Z W 0 0 co N O a vs z a n C NJ a o A 0 c SOUTHWEST = W Z 0 � � o REAR ELEVATION a F- 0Zm > o W � � CL C� w U W IJ J � J O d DATE: 02/20/18 SCALE: 1/4" = 1'-0" DRAWING#: A 2 Y RISERS14 Exit Travel; #2- 89 ft or#1- 108 ft < 250 ft w/ Sprinklers or M I- 7" RISERS/ - - - - - - - - - - - - - Z I " TREADS I FOLDING CHANGINGSingle Exit Travel; #3- 81 ft < 100 ft w/ Sprinklers Z O LO III I I TABLE 0 Note # Description Z w PROPOSED ' ' EXIT TRAVEL LINE#1 I � WALK-IN I I 31 ��� I I H 1 Initial Guidelines for the Hood/Gas Appliance/Fire Suppression w w U) APPROX. 10' X 12', I I ,' O S' op < CONFIRM DIMENSIONS FW I I I Materials (20 gage stainless) and Construction O `� °° = a- _JF- LEVEL WITH FIRST FLOOR, I _ I (liquid-tight welds or braze on external joints). (n W a w CONFIRM SET BACKS - w - Y - > J Q EXIT RAVEL LINE#3 51x3011I I I ---_-- I J, I Internal joints to be sealed grease tight. o Z W Q Z WORK ___ I FOLDING Clean-outs shall be provided for access to all parts of the exhaust ducting. w Z 2 PROPOSED © DERTAB b ILn CLANGING Enclosures and terminations shall ail be non-combustible metal. o &5 � w (D REFER TO DOWNCAPE ENG. DECK BBELOW I - O TABLE I _w wa2Z CL SITE PLAN FOR LOCATION SINK I I Hood Capacity - Type I hoods for Heavy Duty - Wall Mounted Canopy > m w = � NAND ------ OI _ 400 CFM per lineal-foot of cooking = 6,800 CFM (approx. 17 ft) z 0 0 SINK I 2' 4 BURNER RANGE This will probably be best handled w/ either a pair of fans or a speed modulated fan O ao Cc o0 00 _00 PROPOSED Q j ► o PREP AREA I I �GUAPb SPLASH I 3'-2" CONVECTION OVEN Make-up Air must be provided. Draw from open air system. w I 0 I ------ I _ ... .... ..,.. [� c� oaoo AT SINK g 'FILE _ J }Ig�jIND I EXISTING V MOOD Fire Extinguisher - 10 Ib BC. Verify w/ Hyannis Fire Dept. p \O/ \0 ,O I PR POSED SIt! �/ Manual fire alarm pull station I— E r - - — — �� /� OM V 2 O �❑ Canopy to Cover Line; Extend 6" beyond work surface . Bottom edge to be 68" AFF 301PLUMBING �B TH I ❑ OPENING 36(,a2 v ° CHASE ( � \�� � All stainless steel Work Surfaces. ` PROPOSEDGAS ELECTRIC'^ --- ROPOSED I �-- E �► 1 hr remainingwalls and ceilings w/ high-grade aint finish METER ________� CUT BACK-] KITCHEN TILE BAR P� ATTIPANEL - gp STORA���� AGCEss Gas manifold controls; main gas valve, +, T EXISTING ( - BEAM I 30108 PR POSED fire suppression and hood fan inter-connect valves w/ manual re-sets N G-AIR INTAKE - CHASES _ 16'-*211 a'�� `` I M NIS zl _ _ _ _ _ ,� Manual switches; hood fan(s), hood lights and general lights - EPDXY IY WAIT STATION tip RHI] V B 3 LOOR O Standard 3/0 OUT-swing exit door w/ panic style hardware CHASESUST VENT - F 1 __ �� �`�� F Restrooms - Continuously operating fans: Mens - 150 CFM, Womens - 100 CFM J L I / O O (I I — - CVAC SW NQ — — O ADA compliant Handrails, Mirror, TP Holder W t Q _ 4` " — 2668 Q- Q L EPDXY 6 CASED' SWE F TV r\ I, --1 ICE +, A ill' FLOOR {OPENING I ABO E ---� � -- O VAULTED CEILING \ i i VAIVLTED CEILING 16'-2"+- M A.5 -- I I I I — I I A.5 Q E 00 � r-- + � ABOVE I ❑ ICE j I❑ j DUMP _ PROPOSED `�\ Z ). H1 1 FOR HVAG I U.1 O I I O SINK ; DECK EPDXY I I I w __ Q r+ I I D > O FLOOR DRAIN I o m FLOOR o m � J' CUT BACK \ I \ PROPOSED _ \ I - ------------- �� 0 EXISTING _ `�' ' AR AREA I Z i L J I > NAND t_ BEAM o NAND > \ � ❑ FLOOR SINK � 1 I L J . I 0 ~ SINK OSPLASH > AIR STANDARD 3/0 (MIN.) �\ 0 GUARD I SINK OUT-SWING EXIT DOOR \ w CURTAIN W/PANIG STYLE HARDWARE H1 AT SINK I I EXIT - -_ F 3611 I PROPOSED OPEN V C III I P1 OUTSIDE DINING w EPDXY III PROPOSED CHASE I I I _--_-- 28 \ >Y FLOOR SERVER AREA I I BANQUETTE � I I III I i n EXIT TRAVEL LINE#1 I PROPOSED I BARRIER LN ��\ 23 0 1 LINE 8'-10" I 8'-IO" TV DECK 1i I 1.1 I I A/G I I NAND III BAR DIVIDER WALL W/ CO UMNS - - - - - _ —� SINK TV LJ Li I O31 SY211 _ I \ I / I 4'-B211 NIGH TABLE \ / SN OF MASS9 T.VARNUM cyGs� N I pHILBROOK PROPOSED I I F-I 1 I MECHANICAL No.30690 W DINING AREA w 2V III VINYL I \ / PARTITION WALL 42"H TV Ti 36r GATE j S/o NAL E PLANK i \/ i PROPOSED N -------- ------- 43 c�'_P 'Zn0 Z I l a o 0 1 /'"\ 1 DINING AREA � � ---- -- - -- J S s � Z < I Q N VINYL I11 - - 1 011 51-Oil 31 Q11 PLANK I I h I 44 Q 11 1 PROPOSED AREA �I MOBILE HOST ENTRY 62 SO. FT _ I S;ITATI N !1 LO DINING 1, 073 SO. FT >; �I I o N // RAISED o /n BAR (o58 SO. FT. J 44 ZI o � � 1 / / 12ILIFLG T j HIGH TABLE HIGH TABLE TOTAL SEATS BANI�DOEO D�ING 3�8 SQ. FT. - Z 1 3 i , `\ i Q Q KITCHEN/STORAGE 845 SO. FT. _ W Q -N I _ __ __ ______ __ __ __j�______ _____\_� >L3 _ __�4_ u 120 v-- ------- ---- ---- 4Q BASEMENT AREA 88q SO. FT y pJ_ SPLAY 1 I // E 1 PLAYI'\ 1 w`r 0 Q �! N S ACP EXIT \I W ----____-- __--- ----- ---------- DOTAL AREA 44330 SQ. FT. a ,Z CO O ----- ------- ----- ----- ------- ----- ----- ------- ----- c W a�in J \`�j \V'� \`V \V'� `�/ \V EMERGENCY SYMBOL KEY a U_ a STANDARD DBL 3/0 (MIN.) EXIT EXIT LIGHT SIGN I- i I i W/O MULLION BAR (_`1 U + + OUT-SWING EXIT DOOR - w tv N W/PANIC STYLE HARDWARE �E EMERGENCY LIGHT _J , O '-_ 1 It l EMERGENCY LIGHT ti= H ~SINGLE HEAD C- I ALARM PANEL (3'-5"+- 5'-2° 51--011 EXIT EMERGXIT ENCY COMBO LIGHT/ LANDSCAPING F III FRCP FIRE ALARM CONTROL PANEL I H❑ FIRE HORN SCALE: 1/4"= V-0" MANUAL PULL STATION 1 Iq.5" GRADE TO < HORN STROBE DRAWING#: O FIRST FLOOD 1 In a I` zQ S❑ STROBE (JF FIRE EXTINGUISHER � G'-2Y2" G'-2" G'-2 2II NOTE: ALL LIGHTS TO HAVE BATTERY BACK-UPS 8'-7"+- 18'-711 5'-011 I6'-211+- i " Y 10 E14 �_ - - Exit Travel; #2- 89 ft or#1- 108 ft < 250 ft w/ Sprinklers or M 7" RISERS/ Single Exit Travel; #3- 81 ft < 100 ft w/ Sprinklers z o FOLDING >_ �i II" TREADS _ CHANGING O 4J III m I `O TABLE Note # Description Ili w PROPOSED EXIT TRAVEL LINE#1 I I N ( W Q U WALK-IN I I7 A. � ��� I / 1 H1 Initial Guidelines for the Hood/Gas Appliance/Fire Suppression W W m APPROX. 10' X 12', I I I // CONFIRM DIMENSIONS w I 1 Materials (20 gage stainless) and Construction � a J LEVEL WITH FIRST FLOOR, - - I _ I 3 // (liquid-tight welds or braze on external joints). to a ❑ CONFIRM SET BACKS EXIT TRAY LINE#3 LL' O III -- / Internal joints to be sealed grease tight. 17 °� w > 8'x30 ---- _ Y z o Clean-outs shall be provided for access to all parts of the exhaust ducting. w z z WORK ------ I i FOLDING ❑ - TABL Enclosures and terminations shall all be non-combustible metal. cn V W PROPOSED �p� / _----_ I Q TABLE-7 ING I V) W Z REFER TO DOWNCAPE ENG. DECK I I °� --_-_- I O Hood Capacity Type I hoods for Heavy Duty Wall Mounted Canopy > m m - SITE PLAN FOR LOCATION I p y yp y py W Q W 00 00 Co Co HAND I ------ 1 1 - -�3 400 CFM per lineal-foot of cooking = 6,800 CFM (approx. 17 ft) Z cc E- -- W SINK ------ 2 4 BURNER RANGE This will probably be best handled w/ either a pair of fans or a speed modulated fan o ,- PROPOSED I co I ( 3'-2" CONVECTION OVEN Make-up Air must be provided. Draw from open air system. w M o o I � PREP AREA 1 I _ L------J O O O O O I I 1 E I- _ I EXISTING 6' HOOD I s TILE +� ND I ,� ° Fire Extinguisher- 10 lb BC. Verify w/ Hyannis Fire Dept. \O/ PROPOSED � SI K �/ ° Manual fire alarm pull station / \ �� I OM N► O m �❑ ° Canopy to Cover Line; Extend 6" beyond work surface Bottom edge to be 6'8" AFF O � - 2 • 36" PLUMBING �BATH I `. All stainless steel Work Surfaces. ❑ OPENING 36(4)2 a �' CHASE (� PROPOSED \~� ELECTRIG�` g g high-grade P GAS --------- � CUT I 1 hr remaining walls and ceilings w/ hi h rade paint finish EXISTING KITCHEN I TILE BAR P it ATTIC PANE Gas manifold controls; main gas valve, 4- METER -- { STORAG�,i ACCESS �'' T--�--- BEAM 1 I I ' fire suppression and hood fan inter-connect valves w/ manual re-sets (V 30168 PR POSED a 6-AIR INTAKE ' O ,� LL Manual switches; hood fan(s), hood lights and general lights CHASES _ I iiS�I M N S — — — — — v \ I 0 L�1 a zl WAIT STATION O - I I B 3 ELOOR 1� Standard 3/0 OUT-swing exit door w/ panic style hardware V 1 - \ 1 _- , �, m/ ��\� F Restrooms - Continuously operating fans: Mens - 150 CFM, Womens - 100 CFM N 2-EXHAUST VENT F { - W -If• _ _ _ _ _ _ _ v fV CHASES i 1 — —/ — NV O QAc BL ADA compliant Handrails, Mirror, TP Holder j 00 O O SWING C � � y� U N = i 6" ASED SHE F TVA. I� 2668 ICE O L EPDXY pPEN NG ABO E - 1 �� �� � "�— A -J I I 1 I VAULTED CEILING \ / VAIVLTED CEILING < A.5 Q (� ' SOFFIT I ICE I I DUMP--)--, \ ❑ - PROPOSED >- O _+ 1 ABOVE O 1 O SINK DECK H 1 FOR NVAC I '� EPDXY � I I w �� O FLOOR DRAIN m I I I o m FLOOR I / \ I \ PROPOSED D � m ------------------� \�� W Lo CUT BACK = Q 1 , 1 1 \ d I ❑ FLOOR SINK -, EXISTING > ,BAR AREA HAND BEAM 1 0 I �' L J HAND > STANDARD 3/0 (MIN.) SINK w \ I__ 0 SINK CURTAINOUT-SWING EXIT DOOR \ ❑ \1 I W/PANIC STYLE HARDWARE EXIT H1 OSED OPENING I OUTSIDE I 1 — TSIDE DINING Hvac III I ©CHASE - - 28 LL EPDXY PROPOSED - ----- BANQUETTE FLOOR SERVER AREA BARRIER- XIT TRAVEL LINE#1 1 PROPOSED 1 LINECEILIN 8'-10" a'-10" TV DECK i A/c I 1.1 1 HAND N D III BAR DIVIDER WALL W/ CO UMNS1 4 L - — - — - — I NIGHTCLUB UPGRADES — — TV FOR OCCUPANCY >50 I 1\ I Li / NI I \ / I77 1 I I. Sprinkle IAW Sec. W 3'115VI - i \\ I 4'-31'2" g03.3.1.1 IBC 2015 po QI \\ // I HIGH TABLE I 1 �,qN of MIS. r 2. Foam/Plastics t Interior Z I 1 I 1 \ , 1 1 �`� s. 0 Finished regulated by Sec. al 1 \ / 1 1 I o�' 803.4 IBC 2015 L - - - - - - � m I I T.VARNUM 3. Entertainment Response PHILBROOK MECHANICAL "' � 0 I No.30690 a automatically illuminates I I i i . o means of egress, house I { I I F- I \ I / o2 co lighting and stops all sound ( PROPOSED \\ // and visual distractions. w I BAND AREA - I �DNAL ENG J _ - 8 III PLANK \\// PARTITION WALL 42"H PROPOSED TV 36Y GATE - _J 1�J S g Z 4. Main exit sized so all I t` ___ _ __ means egVal or exceed j j d o = - Z ~ 72" via. side-hinged doors �� Q I N I I11 - - o I p" 5' Q" 3'i0" DINING AREA / `\ PROPOSED AREA �t w/o center mullions GQ I I I I Il i I 44 1 ENTRY (o2 SO. FT = z a'xa' I ail MOBILE HST i , DINING 1, 073 SO. FT BAND AREA 1 I u l S ATI N 1h n ' _ ,/ NIGHTCLUB LAYOUT BAR 4qg SO. FT. = J a F- L — — — — — — J QI I p , RAISED I �? OUTSIDE DINING o / I CEILING 1 TOTAL SEATS BATNRoo>�Is 308 SO. FT. *- VINYL QI J i // ±12 FLAT i NIGH TABLE HIGH TABLE KITCHEN/STORAGE 845 SO. FT. 's Q W z PLANK Cp I - < 3 I / \\ 1 Q `( _ 100 C Q _-I---- ----� -I l� 3 _ - -- ---Ll -- r BASEMENT AREA 88q SO. FT. � � p� tL --- ------ ----------------__ I / SPLAY i E Y \ i w� TOTAL AREA 4, 330 SO. FT. y W OPLA O cv S ACP EXIT \ im ---------- ----- ----- ---------- ----- ----- o W o� ----- ------- ----- ---; ------- -�% `�- ------- -,' a EMERGENCY SYMBOL KEY �„ LL N EXIT EXIT LIGHT SIGN STANDARD DBL 3/0 (MIN.) E- U i - " EMERGENCY LIGHT W LLI W/O MULLION BAR + + - OUT-SWING EXIT DOOR - 0 LANDSCAPING W/PANIC STYLE HARDWARE N W ~ LANDSCAPING E SINGLE HEADLIGHT F- co co E ALARM �� E EMERGENCY LIGHT/ PANEL 13'-5"+- 5 -2 5 -0 EXIT EXIT SIGN COMBO F EXIT FACP FIRE ALARM CONTROL PANEL \ 1 H❑ FIRE HORN SCALE: 1/4" = 1'-0" I o © MANUAL PULL STATION DRAWING#; 119.5" GRADE O ` HORN STROBE a \ FIRST FLOor4 p \ Q S❑ STROBE r F FIRE EXTINGUISHER 3ml 6'-2142" 6'-2" 6'--2Y21 NOTE: ALL LIGHTS TO HAVE BATTERY BACK-UPS Y Q ROOM FINISH SCHEDULE m Z �1 ENT'NG ROOM FLOORS WALLS CEILING o co ENTRY EPDXY PAINT (DECORATIVE) PAINT PAINT W w DINING AREA EPDXY PAINT (DECORATIVE) PAINT WITH ACCENT WALLS BRICK PAINT AND ACCENTS OF V-GROOVE w < v 2 1 AND WOOD PANELING (V-GROOVE OR BARNBOARD) o < m WALK IN ---1-- BAR AREA EPDXY PAINT (DECORATIVE) PAINT PAINTED V-GROOVE PANELING cn W < = w COOLER _ BAR PREP STORAGE EPDXY PAINT (DECORATIVE) RIGID VINYL PAINT o as o O I Y ? > Q EXISTING N A SERVER AREA EPDXY PAINT (DECORATIVE) PAINT PAINT w Y 0 I- v VENT I I KITCHEN EPDXY PAINT(DECORATIVE) RIGID VINYL PAINT w z 2 z 1 PREP AREA EPDXY PAINT (DECORATIVE) RIGID VINYL PAINT > m w WOMEN'S BATH PORCELAIN OR CERAMIC TILE HALF TILE WALL w/PAINT ABOVE PAINT Z � � - W U_ I O Co 00 00 00 00 MEN'S BATH PORCELAIN OR CERAMIC TILE HALF TILE WALL w/PAINT ABOVE PAINT u� ; I > o N `r° � 0 OUTSIDE DINING COMPOSITE DECKING W M C) C) 00C W o 000 o BASEMENT OFFICE EPDXY PAINT (DECORATIVE) PAINT PAINT L I0 o BASEMENT STORAGE EPDXY PAINT (CONCRETE) PAINT PAINT c m BASEMENT BATHROOMS EPDXY PAINT (CONCRETE) PAINT PAINT F Exit Travel; #2- 89 ft or#1- 108 ft < 250 ft w/ Sprinklers or FEY I T-1 I P n CONCRETE SLAB N 1 = Single Exit Travel; #3- 81 ft < 100 ft w/ Sprinklers Ico Note # Description 4-1 cu 8Initial Guidelines for the Hood/Gas Appliance/Fire Suppression 8 ELECTRIC "U V PROPOSED PANEL Materials (20 gage stainless) and Construction N OFFICE (liquid-tight welds or braze on external joints). zI III \ Internal joints to be sealed grease tight. +, J I PROPOSED Clean-outs shall be provided for access to all parts of the exhaust ducting. L1J v "t " �n w 2-2x10 P.T. +Z p Enclosures and terminations shall all be non-combustible metal. cn 0- CO Q Hood Capacity - Type I hoods for Heavy Duty - Wall Mounted Canopy •M o A x I A < 400 CFM per lineal-foot of cooking = 6,800 CFM (approx. 17 ft) p� m A.5 III ,A.5 This will probably be best handled w/ either a pair of fans or a speed modulated fan (/) T-- ' q Make-up Air must be provided. Draw from open air system. Z i " 0 I } 7 -6 1 III I Fire Extinguisher - 10 Ib BC. Verify w/ Hyannis Fire Dept. o ------------ ---J W 3-2xB 1 Manual fire alarm pull station z Canopy to Cover Line; Extend 6" beyond work surface . Bottom edge to be 6'8" AFF w — — III All stainless steel Work Surfaces. I 4/ P.T. EXISTING DECK 1 I \`\`� POST 1 hr remaining walls and ceilings w/ high-grade paint finish I III ` Gas manifold controls; main gas valve, PROPOSED ------------------ 1 \�`� fire suppression and hood fan inter-connect valves w/ manual re-sets STORAGE I I � Manual switches; hood fan(s), hood lights and general lights C14EMICAL I STORAGE I , 1� Standard 3/0 OUT-swing exit door w/ panic style hardware I I I I Restrooms - Continuously operating fans: Mens - 150 CFM, Womens - 100 CFM CAWL 1 ACCESS I O ( ADD 6"xG" P.T. POSTS I I I L — ON 24"x24"x12" FOOTINGS O 1 Q ADA compliant Handrails, Mirror, TP Holder I 6x6 6x6 (- _ _ _ 17% , _ r I EXISTING DECK DQ - - - - - - - - - - - - - I I L.J 1 6x6 D-FIR L_ — L — J L_ I 4x6 TIMBER GIRT I I 1 ADD G"x6" FIR GIRTS I w/SOLID POSTS 6' O.C. EXIST. - I N HVAC I I 0EXIST. I 1 o ADD 6"x6" P.T. POSTS j 2xB P.T. DECK W/H I +i ON 24"x16"xl2" FOOTINGS I I JOISTS 16" O.C. I o E V-7" _ _ _ _ _ _ _ _ _ _ _ _ = I SEE FRAMING PLAN M - 3-2xB K.D. I Ql� �a 1 N ------------ --� Z I 2 ADD Ox6" FIR GIRTS II I 2)2x10 P.T. y��cp���OFMgSsgc`� 'Z w/SOLID POSTS 6' O.C. 2x10 P.T. LEDGER III HEADER yG Q T.VARNUM N '. w/2) 5/s" DIA. III o PHILBROOK r- — -1 f— -t r_ BOLTS 16" O.G. 6"xG" P.T. POST " MECHANICAL �' A _ -_ - G® - - - - - - - - — TYPICAL No.30690 4 -o S /� N Z I - 6"x6" P.T. POST 6x6 6x6 D-FIR L_ J 6�_0u J 6' 0u L_ G = �Q�jj Q 1 = TIMBER GIRT /DNAt E�Ga�' O00 �lr J L2 0 - ++ N _ 'P ADD 6"x6" P.T. POSTS Il SIMPSON ABE66 �3✓ ?h ih' W I- ON 24"x24"A2" FOOTINGS II _ LU �" LOCKERS I - E +� I p � p 19 W LU _� cc PROPOSED 2-2x10 P.T. N W 47 3 U) a LU ° EMERGENCY SYMBOL KEY 102 Ln CO ill PROVIDE 16" DIAM. I PROVIDE 16" DIAM. a a EXIT EXIT LIGHT SIGN SONOTUBE OR ADS III II - SONOTUBE OR ADS ° Z �, U FOR COLUMN III a FOR COLUMN a a ° - L E EMERGENCY LIGHT J SUPPORT ABOVE 'II II SUPPORT ABOVE � _ II I ItJ EMERGENCY LIGHT � F- SINGLE HEAD 6'-11" III 4'-2" I:12 RAMP DECK POST DETAIL EMERGENCY LIGHT/ / EXIT EXIT SIGN COMBO II II UP N SCALE 1-1/2'� = 1�-O'� FACP FIRE ALARM CONTROL PANEL "— —— — — — _ H❑ FIRE HORN SCALE: 1/4" = 1'-0° i P MANUAL PULL STATION I EXISTING DECK „ , „ II o O -0 II 6 -0 II HORN STROBE DRAWING#: ' II I I � — — — � STROBE -———— ————- --———- - F FIRE EXTINGUISHER NOTE: ALL LIGHTS TO HAVE BATTERY BACK-UPS Z O_ W LY GX(o RECLAIMED WOOD BEANS N u V-GROOVE PANELING 2! LINE OF S '�"' r.�1 ® C) GANNON e e L l 0- co VAULTED `� .� T CEILING AREA 06 D m RESTROO v� fu BEYOND BRICK VENEER 55" TV 55" TV 55 " TV 0 z � �- �, co - - - - - - -------- - - - - - - - - - - - - 7T7 - - 0 W 0 JL - --- KENO ET ------- 55 ,E Tv Tv CENTER Q ISLAND BEYOND z z z O PROPOSED N NJ Q BAR/ VAULTED CEILING wINTERIOR ELEVATION ._ U) -i c 0 w v0 � Z ui c IL Ul 0 � z U W 6i O J w IL DATE: 04/02/18 SCALE: 1/4" = 1'-0" DRAWING #: Y U d m Z Z 0 0 LLICV e- LLJ X Y � Qmm 0 U) wdZ) � 0C � o � z © g = W Z Z U uJ— CL z re �-- vUjL 0 00 co 00 coo coo o �r 0 o c r- . r. co a WmiB `mrn o a000 I I tn I I I I I 4 PASS THROUGH ICE BIN (n V) Ln i > w Q) iN L/ Q, 00 • N - - - - - - - 29 DUMP SINK m 2i 0 m i ICE BIN i Q o U-) � � I P.O.S. P.O.S. ; m i i w z WORK TABLE0 i w i WORKTABLE j j DISH MACHINE i DRYING TABLE COOLER HAND SINK `� HAND SINK COFFIN BEER COOLER ICE BIN O p I 36 I Q 35 � Q /--------------- ------- ------- -------- = OW � - - - - - - - - - - - - 0 0 — — — — — — — — — — — — — — — — y W S„ Z m D= UNDER BAR SHELVESL/ UNDER BAR SHELVE L W 0 Q m U W � J 0 w d USB PORTS ALONG OUTSIDE OF BAR COFFIN BEER COOLER 49" WIDE WORK TABLE 24" WIDE 0 FLOOR DRAIN SCALE: 1" = 1'-O" DRYING TABLE 36" WIDE DISH MACHINE 24" WIDE ❑ FLOOR SINK DRAWING#: DUMP SINK 12" WIDE HAND SINK 18" WIDE PASS THROUGH ICE BIN 24"x36" UNDER BAR ICE BINS 33" WIDE I 30 -0" CUT BACK Q EXISTING FLOOR m >- /- JOIST TO PROPOSED 4 LVL SIMPSON HB HURICANE TIE XIS SS A I u 2x�RAFTER TIE O ACCOMODATE TAPERED TO 5�2 AT HEEL 2x6 TOP CHORD Z �. PROP. STAIRS DBL. LVL's AT EXHAUST FRAME DOWN w/2x4 2x6 BTM. CHORD O CHASES SINGLE AT INTAKE VERT./HORIZ. 2x10 SISTERED TO TRUSS _1� ,,1� 13 2x4 WEBS z _ CHASES AND THEN 16" D.G. NAIL TO SISTERED ,T w/PLYWOOD GUSSETS W Z 2x10 OVERALL ON 2xlo TOP CHORD OF ,,�>"' �� I �T " �\� X Y w „ TRUSS REMAINS - ' Q ------- --� - ____-- 1'�-2xG DROP�ED EACH CH SIDE �� �� ����� -14" L�/k�RIDG � �� \��,�� SIMPSON N2.5 HEADER w/1/2" CDX 0 0 `T �i �� '172x4 LATERAL STRUT '� O 4 - -—- - - ---- - /w/DBL JACK STUDS / 000 �' 12 1 1 ~ \� ��i' = d _J H _ EACH END --__ yyJ �%-----LATERAL STRUTS _ W � --- - __� --------�---- - ! - /// j /// j //// o ___________ _ .--- -- --- ---- CAN FLUSH FRAME __ F_ w �" Z --- - - // // / // / // SHELF REMOVE WEBBING --- ALIGNED w/THE Y Z > Q ABOVE FROM TRUSSES AT BOTTOM OF THE w Y I- U -- -- / / f/ / f/ / SIMPSON H2.5 EACH BAR AREA ® LVL BEAM TO BE VERIFIED UJ Z 2 Z O SISTERED 2xI0 TO PLATE/BEAM CONNECTION SIMPSON H2.5 14 AROUND BAR � .WJ ro C- g (VERIFY AREA) PROPOSED W Q LVL FLUSH AND /f // // // H2.5 CONNECTION PROPOSED < 2 W 5 - - - - - /JOIST SCREWED TO FLOOR / // // // /// KITCHEN BAR AREA o Co Co 00 co Co / / / // /f /// f i mco o w M cor. 00rn .� O N 0 •� a 0 0 0 w 2x102�� /// // /// // /// // //// j // / / / // FIRST FLOOR (SUB FLR) — CDX FLITCH // // // // // // /// / / / / / // / / - - -CONCRETE SLAB - - - - CONCRETE SLAB PIECES �IhTllllllllll_Ill l - - - - - (--�IITI � - - // /// //f / / // EXISTING III-I IT / / / / IIL CRAWL SPACE CONCRETE SLAB PROPOSED TTI II II II I� IIII - --- - - - - - // // /f /// f / / / / / / / / / / / / / / / / / / / / / // iIIIIIIIIIIT�IIIT lll- ,�_, STORAGE _h -- - - - o - - - - - ELECTRIC - -- ---PANEL / / / /,/ , / //, // /, SECTION A-A (10 - --- N - --6 - 7 _ //// // // / - --- - - -- III --- ----- %///%j /// / '� SCALE: 1!4" = 1'-0" V -- - -- --- - - - / /// f/ // / / SISTERED H2x10EACH LVL o°o --� J PROPOSED 2x10 W N - - = U= = __ _U = /f j f f /// / f f f \ \ 2-2x10 P.T. RIDGE o 0 d / Cn 00 p I O I'-I� j // f / // / f - - -—- - - - - - - - /// / / / / / / P.T. 2xBI�DECK t J N JOIST 16 O.G. . r41-0 cl� --- x - --- - x / / / ----- - U - -- III - - - - - / / j oo (� � � / / / f / / / / / f / ,A.S oo OL' � � m _ _ _ _ / // / f / / / / ----- - o - - -—- - --- j , / / / / . r o - ----- - - - o ---- 0 �/ / / / / / / / / - - - - ---- ----- ----- - - I - - _� Lu - - - - - -- F-2XII - --- - - f ------------------ I� LVL RIDGE Z ---- - - - ---- f f f / / / f / / / / // - - - - - --- - - -_ _ = = = N / / / f - - - - --- III - --- - - / j j f / / j/ j / - - - - - --- -�---I-- -`�� H8 CONNECTION W - - - - - - --- -—- -—-—--+ - - --- - - P0�'. - - EXISTING DECK - - - / III / / // / / / // / 1 - - - - - / / / // / / / / - - - - - - - ------- f / - - - - - - ---F \ $ / / / - - - -—- - / / / / / 3-2xB - / / / / / / ------------------i FILLED NC. 2-2xB I6" O.C. 2xB 16" O.G. I----- --- - OF - --- - - - STL.LALLY I— I I I I �� T.VARNUM � x 1 = 3-2x10 I 3 2xe i o PHILBROOK y O ( I - - ----- ----- - -� « MECHANICAL No. ' - -- - - - - - - — ADD 6"x6" L_,— P.T. POSTSI - I- --- I -- - - -- I --- ---- �� �� �� �� �� �� �� I6x6' � � � '-0°� � � � 6�-p�� � � j— I I EXISTING DECK 6x6 --II— 1�N = _ I — P.T. 2xB DECK I - - - I--- - ----- -�1 V3 �E.�Z-a1$-- - U -- ------ - 7 a 6x D- I II — � ` = 11 — I JOIST 16" O.C. I I --- 0 - --- - - - — 4x TIMBER GIRT �� �� �� � � , " - - I--- - I ADD G xG FIR GIRTS I !' It I w/SOLIp Pr TSI 6' Q.G. i - I- - - --- - - - _ _ EXIST. - - — 1 1 '� " I ;-- I -I , I FRAMING NOTES cv HVAc 11 11 ! I NOTE # FRAMING DESCRIPTION O _ _11 HANG Q F=- f � T 2 END OF BEANI I 1 Outside framing is not inventoried at this time W _ _ � � .. W i - L� 3-,2xe � �— — - .� - - - - - - - - 2 Floor joists break and are lapped along this bearing line U) H- -f - - - �f - f -I- 1- - - - t- -t z 0 CI II --------- ------------ --J 3 Check these floor sections for stiffness/bounce or sagging IADD 6"x6" FIR GIRTS I 4 Badly damaged sub-floor needs repairs/replacement w/50LID) POTS I6' O1C. II III 11 6x6� 6x6 � � � I �—� - — .I— -- — = _ -I 1—_ �— — II ( I 5 Sagging floor at stairwell. Jack and install 4 x 4 PT wood post m - - - -O - - — 6x6 -_ ,GX6 D- IY R ® i' i i - T� - — r T — , u� I , "— — 1 n n fA e TIMBER GIRT I I f -p G 6 If 2 x 6 on long-span side sister w/ 2nd member = "� - --- --I -- - -— I J z ADD G"x6° I PROPOSED � 2-2xB IG" O.G. 2xB IG" O.G. P.T. POSTS II 2-2x10 P.T. 7 Install Simpson LUS series joist hangers for joists and header a W J 2x 10 P.T. LEDGER w/2) 5/a DIA, 8 Sister 2nd 2 x8 to trimmer joists 0 � U) BOLTS 16" O.G. PROPOSER � � W Z - --- - - ----- — 2-2xI0 P.T. 9 Dropped Ridge Beam; 3 ea 1.75"x 14" LVL members. Fasten both sides w/ 3 ea 3-3/8" Trus-Lok screws @ 12" o/c o z m I PROPOSED 10 Dropped ROW OF SOLID BLOCKING pp d Door Header; 2 ea 1.75"x 9.5" LVL members. Fasten o W W OVER t ALONG THE GIRT LINE " 3 I et " a. � � I 2-2x10 P.T. from 1 side w/ 2 ea 3-3/8 Trus-Lok screws @ 12 o/c. Provide � PROPOSED—CFI header w/ double Jack studs 2-2x10 P.T. I U II 11 Support Post (to beam below); 4"x 6" D-Fir solid stick o I, I Bois r xl6"O CKII 12 Sister 2"x 10" KD-SPF to top chord members. Run continuous °' I- I and nail to chords w/ 2 rows of 16d nails @ 16" o/c I PROPOSED III 6"x6" P.T. POST 13 Ridge Assembly: 2-2x10 P.T. TYPICAL g a. Clear any interfering wires, pipes, etc. 1:12 RAMP b. Install sister 2"x 10". They need to butt tight at ridge, nail SCALE: 1/4" = 1'-0" I I I EXISTING DECK I P. 2xB D GK C. Install 2"x 8" rafter tie/bearing block each truss assembly JO ST 0' C. I) UP d. Fit-up the 3 LVL members tight to the bearing block. DRAWING#: HANG THIS I Assemble the LVLs and install Simpson H8 Hurricane END OF BEAM ties from the LVL beam to the rafter 2"x 6'710" rafter sets PROPOSED e. Install 2"x 4" lateral struts each side flush with the bottom of - 2-2x10 P.T. the LVL beam 14 Install Simpson H2.5 Hurricane ties to wall plate/beam packing U Q L_ Z ID 0 CIO II X Y W QUA U � Xmm owt = W o Wow II ------ z > .� a I I ------ I W z 2 z U I 0--- W ,.. z2 _z U) WmaE ------ w Q W = Q ------ ® O 00 CO 00 00 _W EXISTING FRAMING I I W �o 0 0 0 0 W � o`o � TO REMAIN I I - I �� p O O OI i \ GUT BACK EXISTING 36(,)24 � BEAM AT KITCHEN -- _ _ _ 10 WALLS AND POST I X SISTER ON 2x10 EACH TRUSS DOWN EACH END T ---- _ _ = _ —� SEE NOTES 12-14 �+ IT II -FI - --------- --- - 0 �1 II - I- I EXISTING TRUSSES �- _ I -- ------------- ----------- -- -- ------- -- - --------- -- N I- - �II\\ II _ Q� --------- -- I/�\\ V) - - - W --- ----- ----- I-- ----------- — — N +-' 2-EXHAU5T VENT r _jj / I _ _ — • 1 00 L CHASES A I I II I I �'I �' ElA Q m m ------—- —- --- --—- I — \ i I I I i -— --—----- - - --—----- -- A.5 c./) V_ 00 �[Q 6-AIR INTAKE - Ih - -- ------ 1 - I I I i - < V Z r,, y � CHASES - PROPOSED �'4° I I = I m - --------- - s 1 _ o LVL TAPERED I i --J- - - W TO 5Y2" AT HEEL - -il-- _ - _ —�-— ------—- — - --- —— =-= J'�`�\�---------- - --- --------- I L J I w cn U I W 2-2x HEADERS - I ------- --------- - TYP AT CHASES \I - --------- --- --------- a- -- I -- —� -�-- - - - - ------------ 1' LAND VENTS - - - ROOF L_ _ _ __ __ _DBL. LVL's AT I - - - - - - - - - - - - - - - — — w SCALE: 1 1 0 ��� sq EXHAUST CHASES _ - - o� cy� SINGLE AT INTAKE ----------—-------------— - —---�---- Q T.VARNUM --- --------- - CHASE5 AND THEN 16" I �I 'o PHILBROOK O.G. OVERALL I I I I I -------—- ----------—------- iy_ I �1 No.30690 MECHANICAL --—---—------ --------- -��- - to O I I I I I } — — — — —� —, — — — — — — — — — — — — — — — — — — — — _ SS�ONAL — EN — — ---- ---—— — ------ —-- ---- ---- -------------- I EXISTING TRUSSES — ---�----_ EXISTING BEAM j BELOW FRAMING NOTES II ( 11 11 II - EXISTING TOP 2-2xB w/l/2" GDX I r�; NOTE # FRAMING DESCRIPTION ----1 HORD- MEMBERS $SINGLE JACK, DOUBLE KINGS STUDS I r qk2" LVL w/ 2-2x4 II EACH END I 1 1 Outside framing1s not inventoried at this time EACH END I I THIS END - -- --�---- _ PROPOSED 2x6 CL I 1 IN + LVL SITS ON I JOISTS TO EACH TOP I I 2 Floor joists break and are lapped along this bearing line O N I - LOCATION ONLY. 2nd STEEL BE �___ -1---_ -� 24 O.C. MEMBER SETS 1 I 2xB ATTACHED TO I— - --- _--I I I 3 Check these floor sections for stiffness/bounce or sagging a BACKSIDE OF I I I II j I EXISTING GABLE r"i r r 4 Badly damaged sub-floor needs repairs/replacement \ ROOF RIDGE I - .IJ J -IJ II II 5 Sagging floor at stairwell. Jack and install 4"x 4" PT wood post Z III I I-IIY4" LVL Z <' I SISTERED ONTO I; I 2x12 AND BOLTED 6 If 2"x 6" on long-span side sister w/ 2nd member 4 II I TO EXISTING TOP Z EXISTING FRAMING I III 11 II CHORD MEMBER 7 Install Simpson LUS series joist hangers for joists and header = Q TO REMAIN I IIII ., J THIS END LVL EXISTING FRAMING ++ ++ oil BOLTED TO TO REMAIN 8 Sister 2nd 2 x8 to trimmer joists H J EXISTING TOP 11 11 C CHORD 2-ROWS OF " ++ o 1 1 9 Dropped Ridge Beam; 3 ea 1.75 x 14 LVL members. ._ Z G-5/5" BOLTS I I +w' (12 TOTAL) 2-2x8 wili2" CDX Fasten both sides w/ 3 ea 3-3/8" Trus-Lok screws @ 12" o/c U) $SINGLE JACK, C I ----- ------------- -- 11 -- -- - - --I!-- ----------DOUBL-E K]NCr-5-�T-U_D5- 10 Dro ed Door Header; 2 ea 1.75"x 9.5" LVL members. Fasten 0 --- --------------------------- EACH END pp v x from 1 side w/ 2 ea 3-3/8" Trus-Lok screws @ 12" o/c. Provide it U_ header w/ double Jack studs H Z m Q ---------- ---------- - --- --- - ---------- ----- ------- ----- ------------ ----- ------------- ----- 11 Support Post (to beam below); 4"x 6" D-Fir solid stick c Q V v FRONT�SLOPED CEILING, 12 Sister 2"x 10" KD-SPF to top chord members. Run continuous C. tr.� o� � EXISTING 2xB RAFTERS AT and nail to chords w/ 2 rows of 16d nails @ 16" o/c 24" O.G. REMAIN A5 W EXISTING FRAMING CATHEDRAL RAFTERS TO 13 Ridge Assembly: o TO REMAIN FRONT DOOR HEADER FROM a. Clear any interfering wires, pipes, etc. W 1= DOUBLED UP RIDGE SECTION b. Install sister 2"x 10". They need to butt tight at ridge, nail C. Install 2"x 8" rafter tie/bearing block each truss assembly d. Fit-up the 3 LVL members tight to the bearing block. Ll Assemble the LVLs and install Simpson H8 Hurricane SCALE: 1/4" = V-0" ties from the LVL beam to the rafter 2"x 6 710" rafter sets e. Install 2"x 4" lateral struts each side flush with the bottom of DRAWING#: the LVL beam 14 Install Simpson H2.5 Hurricane ties to wall plate/beam packing S=2 Y U _ Q m PROPOSED I z PREP AREA I , I LEGEND 0 PROPOSED n I I RECE55ED LED LIGHTING F❑ FAN DUPLEX OUTLET/5PLIT WIRED W Z WALK-IN I— Y W O ADJUSTABLE RECE55ED LED LIGHTING sR SPEAKER W uj`I U U) APPROX. 10� X 12', I I a DUPLEX OUTLET 3 m Q CONFIRM DIMENSIONS 1 1 1 I / Q m LEVEL WITH FIRST FLOOR, I _T I �� E + EXTERIOR LIGHT sD 5MOKE DETECTOR M (LJ H CONFIRM SET BACKS I I -- I I �� ,' 220 VOLT OUTLET to XW ct O W CARBON MONOXIDE CL �' U CEILING LIGHT �❑ Z W �Q z DETECTOR 0 FLOOR DUPLEX OUTLET > Q O W m PROPOSED -_ + WALL LIGHT BATHROOM FAN 0 Z UJ U 2 GRINDER O \ I ' \ SWITCH 51NGLE POLE W Z 2 Z_ Ms MOTION 5EN50 -- J m 0- SINK PLAREFER N DORNLOCATION CAPE ' DECK BELOW I ___--- I R ua W — SINK wR 5HOWEK LIGHT RECE55ED > m W Q HAND p I 3 SWITCH 2 POLE 65 W U (� SINK ------ ( LED STRIP LIGHT 0 0o 00 00 00 co T- r �_ 4 I R d o cQ d O I R I N PHONE U_3 '.. '�. '�- ~- `,- Q SPLASH — I __ �' LED STRIP LIGHT > oM to h 00 0) GUARt�- -- ( � / w o 0000 I — ry CATV S AT SINK 6 / I � DIRECTIONAL LIGHTING \ H�N D USB PORT WALL OUTLET` POLE W/ \ /[( I \ / SI K / usa LIGHTING — — — — - - /�\ /� , '� I C��o o FLOOD LIGHT AT REAR _ PARKING ❑ 36 24 PROPOSED R R / ROPOSED 1 GAS -_----- ITCHE , WOME 'S Ao)po��'D m PR SED �/ ELECTRIG� METER --__-- $ I ME S v_ B P� PANEL T � �,,.-- -_� BATH ATTIC 71 1 1 1 1 MS BA S ORAGE\� J ACCESS 15 , - I = 15 � 1 i I II - - - - - N � � I 23 - F ? W r� V T 19 1 I MS - + N ��N Vo Vo AII ' iI- d I I I I I16 I + R F O 1 II 20 [ I —,_ V) o a0 IL Z i 3611 CASED �A����� BAR AREA I � i Y ' iti -1 O m tV 13J 18 @22�\ OPENING I + ----- \\ / I ,' �'\ -"----- _ + W � CYl cD EQUIPMENT WIRING r L_ 11 R 1 R I __..�R R m 00 PER MANF. SPECS. = - I 25 I I \� d' O h 11 C21 ( I I I F PROPOSED \� V 1Z 11 P Pas - , SWITCH DECK \� I�� i I Z6 PO MACHINE } 14 %, I 17 U I Z7 I I I AT PANEL I \� m 1� Q ?" 'J I / I \ I — >- D -- --------------- �� 0 r 10 J L J I O I VAULTED CEILg I ULT CEILING % I - �� U SPLASH + `\I GUARD R R AIR �� W h I AT SINK �. CURTAIN PROPOSED F I OUTSIDE DININ'(�, II I _ , 28 Lu ----------RSERVER AREA BA\N Q\ EK�TTEPROPOSED `\ _ - Tv PROPOSED Pos COFFEE I ( TV DECK 1 A/C - MACHINE-i"IACHINE-I CHINES HAND - ---- `, __ - ---- - + 1 + O III BAR-DIVIDER-tq-AL�W/--C--OLt)i'4NS-,—-- -- � — SINK - - - - - - - - - - - - - - - - - - - - - - - - - - — I I + SWITCH �I I I 1:1i \ ij S ITCH AT PANEL \ ! A PANEL L'�I ICI POLE W/ + OI I SWITCH j \ I ! j �I I Izl LIGHTING AT PANEL R zl , I O R - + / I POLE W/ +I N PROPOSED I I I I I I LIGHTING o jD I N I N G ARE� ~ n Q I I ICI Q W I R LV R I I I R R I �, PARTITION WALL 42"H R \\� Tce � I i a -------- --- ---------------J<\ ( IIFl I i SWITCH—/ \\ +KENO z \, I I III I AT PANEL \ PR P SED E ,C I I DING AREA '' U III I MOBILE H ST I t / STATION of I z z .' \ - "--- / .. �- U o= U) ..t at w c R R j VAULTED CEILING1<1 R j R + ' •OmJ w -- -- ------ -- -- a- 3 I-- /----------\\ a 3 - I 20 = O W O � ! \ -I -- -- -- ------ - v - -------------- ----- ---- SPLAYIli \ \ SPLAY\ LL I! \I ----_-- KENO H m Z ---------- ---------- -------- o ----- ------- ----- ----- ------- ----- ----- ------- ----- a W Q 0 \V V' \� �i �v/ \vi DOES KENO Ln O. � NEED CATV?? 1, U W LANDSCAPING + A A ' 0 H L R LANDSCAPING a 1=- + PANEL POLE W/ + ; LIGHTING / POLE W/ LIGHTING SCALE: 114"= 1'-0" DRAWING#: CAMERA N�c 1.. I 4l't\j I CAMERA -------- I Y C� Q 00 � -- Z Z O LEGEND O U) n I i FO RECE55ED LED LIGHTING F❑ FAN � DUPLEX OUTLET/5PLIT WIRED W N Z X W I I n F@ ADJU5TABLE RECE55ED LED LIGHTING sP SPEAKER �� W U I I I I � DUPLEX OUTLET � A 3S w m m 11 Q 1 I I E + EXTERIOR LIGHT sD SMOKE DETECTOR 220 VOLT OUTLET O III Q Z co W Ab,- I IN I I -- - I I I + O CARBON MONOXIDE � �' W �"' � COOLER, -- I CEILING LIGHT c❑y DETECTOR O FLOOR DUPLEX OUTLET � Z }— � < 1 W Z � Z U I I p(+} WALL LIGHT T BATHROOM FAN SWITCH SINGLE POLE � W Z a Z Es MOTION SEN50R j m m p wP SHOWER LIGHT RECE55ED LI! e[ 3 5WITCH 2 POLE fn W U (� Q Z f- — W Lt_ LED STRIP LIGHT O T-co � 00 � v- t Fn P P P P P N PHONE > ti 00 cQ K p 2 BULB FLOURE5CENT LY o 0 0 0 0 I I ry GATV } o N � P I DIRECTIONAL LIGHTING II I I I U5B PORT WALL OUTLET usB L__1 � FLOOD LIGHT ri CONCRETE SLAB 7rELECTRIC I I PANEL N I i III \ 4-1 L1J � O 0 R to CL 00 III � `„� N 1 I I II \ � °° � 0 Nzkl m PROPOSED vi STOR,�GE III II _ ^, [- L V I I \ � III --------- ------- \\\ w II W I I I I III G` \ EXISTING DECK \\ I \ I I III \\\ I I \ I FENICAL— TORAGE II I I 1 11 I I II I I I I II O I u �- I I I EXISTING DECK 11 L — J L — J L_ II I c II EXIST. II i I i Q NVAC II 1 0 W/N EXIST. Z tl R ----- ------------ II III -- ------- a � r - -I L — J o w R � II c O y ~ z LCKERS I II w W 2 II 0. Z m U LL1 � m III II 111 II � W w III III 0 III II II 1:12 RAMP III II III II 1UP SCALE: 114" = 1'-0" ' II EXISTING DECK I II II DRAWING#: I II II ---------------- - -------------A) pLLJ J 14 RISERS = L-L� 7" RISERS F- LI.1 Of � o 11" TREA S z Of Z O I� Ox< w MOW J 0 D Z M 01= 6 PROPOSED z cn Of J � z J STORAGE — cowozzo I N 1 ~ (n = 0 - wo zw p ~ cn pW cn W :D OZ < I.- PROPOSED / W J m 0 J p Q z w DECK 2. cnQryJI- = J / PROPOSED g = wWQOF- Q F- 0 m: z = REP AREA 0 a o a 5 I 6 ALARM PANEL p To/\ m\0/ 1 PROPOSED n. �A/OM AID ��ll PROPOSED BATH FV BAR PREP/ ® 1 � / STORAGE pANETL IC PROPOSED METER sGAS KITCHEN TILE O ALE ACCESS 15 7 3o6s / PROPOSED � Y • WAIT STATION F O Err, t 9 23 M E N S EPDXY FLY is I w ATH d 9 uj ma S �20) 24 A IGN WALL W/ EXISTIN 13 18 22 VAULTED CEI NG V ULTED CEILING d 2�12 F 29 I I m \ 21 EPDXY Ra 26 :s 14 I I PROPOSED I p m 17 27 d I I AR AREA m 35 309 1 O I I I STANDARD 3/0 DOOR \ I OUT--SYNC EMIT DOOR W/ 0 ° PANIC STYLE HARDWARE \ o— I � EXIT PROPOSED \ ; 13 OUTSIDE DINING \ I I 28 \ F oEPDXY FLO PROPOSED SERVER AREA Z U PROPOSED I 2 c '" DECK 0 W z z V OO U A/C BAR DIVIDER WALL W COLUMNS I Z Z w c� o w Fn w z 000 I I I c=� w w in 0 w mUZ TV Lj U Lj U u u 1 000000 o HIGH TABLE Q � o c o cn s y Y M I I 2 , N , d I I I U o Q D o m I L I W W, 3 PROPOSED w DINING AREA TV 2Q VINYL PLANK PARTITION WALL 42 H PROPOSED 36 GATE cy VINYL PLANK DINING AREA m I 44 z MOBILE HOST ST TION / O Z, ZI ON zC)l `—' HIGH TABLE HIGH TABLE TOTAL SEATS a J d J m Q. 3:: a. 3: 120 1 SPLAY 1 SPLAY p KENO P 06 3068 a W STANDARD 3/0(MN.) c"I OUT—SWING EXIT DOOR W/ PANIC STME HARDWARE ' Z LANDSCAPING W LANDSCAPING U ALARM � PANEL • EXIT V Q (o (W'� 19,5" GRADE TO FI T z C) �✓ FLOOR 0 > W2 W or- � Wz 00 0) < 0 (D � _ ° SCALE: 1 /4" = V-O" FS . I J F- LLJ LLI= � lL (= 4- � F- W O O e� }}.. 0 0 l D_ i_ U � F- ZO z0CKQWw LIc) w _JU � Zn' c) oP 0 cn W _J C9WOZZ0 F- � =U — wV :2 W (J) �W U) 0Z ` If— 0 . � F F=_— 0 Q w J coO= J -i F— J = w WED <COF- Q F— = 2Z = SCHEDULE OF EQUIPMENT ITEM QT. DESCRIPTION ELECTRICAL WATER WASTE GAS EXHAUST MAKE-UP MANUFACTURER MODEL REMARKS w Q aCLi uj a w wJ z a U w o w u w w °- U- MO �l:2 O O Li- O O tom. a l m a o s O ¢ 0 _ ¢ o a ? a cn : a c) U cn C) c) cn 1 4 WIRE SHELVING 24" X 36" - - - - - - - - - - - - - - - - - - - - - - - - ADVANCE TABCO EG-2436 2 1 ONE COMPARTMENT SINK - - - - - - - 1/2" 1/2" 18" - - 1-1/2" FS - - - - - - - - - - ADVANCE TABCO FC-1-1818-X - 3 - SPARE NUMBER - - - - - - - - - - - - - - - - - - - - - - - - - - - wN 4 2 HAND SINK - - - - - - - 1/2- 1/2" 24" 1-1/2' 18" - - - - - - - - - - - - JOHN BOOS PBHS-W-1410-SSLR INCLUDE FAUCET, SOAP & TOWEL DISPENSER BY OWNER'S VENDOR 5 1 EXISTING MOP SINK - - - - - - - 1 2" 1/2" - 2" - - - - - - - - - - - - - EXISTING EQUIPMENT NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY UTILITY REQUIREMENTS WITH OWNER 6 1 1EXISTING THREE COMPARTMENT SINK - - - - - - - 1/2" 1 2" - 3)2" - - - - - - - - - - - - - EXISTING EQUIPMENT NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY UTILITY REQUIREMENTS WITH OWNER 7 1 EXHAUST HOOD 5.0 - - 120/1 JB - DFA - - - - - - - - - - - - - - - - - BY OWNER NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY UTILITY REQUIREMENTS WITH OWNER 8 1 FIRE SUPPRESSION SYSTEM 5.0 - - 120/1 JB - DFA - - - - - - - - - - - - - - - - - BY OWNER NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY UTILITY REQUIREMENTS WITH OWNER 9 OT STAINLESS STEEL WALL PANEL - - - - - - - - - - - - - - - - - - - - - - - - BY OWNER NOT IN FOODSERVICE EQUIPMENT CONTRACT - s 10 1 EXISTING CONVECTION OVEN 10.0 - - 120/1 SR - 14" - - - - - - - 3/4" 70 NAT 30" - - - - - - EXISTING EQUIPMENT NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY UTILITY REQUIREMENTS WITH OWNER 11 1 EXISTING 6 BURNER RANGE - - - - - - - - - - - - - - 3/4" 227 NAT 30" 1EXISTING EQUIPMENT NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY UTILITY REQUIREMENTS WITH OWNER CZ 12 1 CHAR BROILER - - - - - - - - - - - - - 3/4" 120 NAT 30" - - - - - - STAR 6136RCBB - 13 1 FOUR BURNER RANGE - - - - - - - - - - - - - - 3/4" 145 NAT 30" vi - - - - - - GARLAND X24-4L - f. 14 1 REFRIGERATED STAND 5.7 - 1/5 115/1 SR - 14" - - - - - - - - - - - - - - - - - TRUE TRCB-36 - ` 15 2 EXISTING FRYER - - - - - - - - - - - - - 3/4" 105 NAT 12" - - - - - - EXISTING EQUIPMENT NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY UTILITY REQUIREMENTS WITH OWNER 16 1 FRYER - - - - - - - - - - - - - - 3/4" 105 NAT 12" - - - - - - IMPERIAL IFS-40 - 17 1 REFRIGERATED SANDWICH UNIT 6.5 - 1/3 115/1 SR - 4" - - - - - - - - - - - - - - - - TRUE TSSU-60-16-HC - 18 1 HOT WELLS 7.2 1.5 - 208 1 SR - 4" - - - - - 1" FS - - - - - - - - - - DUKE E302SW - 19 1 EXISTING REFRIGERATED SANDWICH UNIT 3.8 - 1/4 115/1 SR - 4" - - - - - - - - - - - - - - - - - EXISTING EQUIPMENT NOT IN FOODSERVICE EQUIPMENT CONTRACT VERIFY UTILITY REQUIREMENTS WITH OWNER zz 20 1 DOUBLE OVERSHELF - - - - - - - - - - - - - - - - - - - - - - - - ADVANCE TABCO CU-18-96-2 - z 21 1 HEAT LAMP - 1.4 - 120/1 DC - DFA - - - - - - - - - - - - - - - - - HATCO GRAH-60 - z W 22 1 1EXISTING PLATE CABINET - - - - - - - - - - - - - - - - - - - - - - - - EXISTING EQUIPMENT NOT IN FOODSERVICE EQUIPMENT CONTRACT - (Ao N 23 1 CLEAN DISH TABLE - - - - - - - - - - - - - - - - - - - - - - - - ADVANCE TABCO DTC-S70-72L-X - in -� z z a 24 1 DISH MACHINE 11.4 - - 115/1 DC - 66" - 3 4" 66" - - 2" FS - - - - - - - - - - BY VENDOR NOT IN FOODSERVCE EQUIPMENT CONTRACT VERIFY UTILITY REQUIREMENTS WITH OWNER'S VENDOR v F o 25 1 SOILED DISH TABLE - - - - - - - - - - - - 1-1/2-1 FS - - - - - - - - - - ADVANCE TABCO DTS-S70-72R-X - ry < z z f5 o cn 26 1 PRE-RINSE FAUCET - - - - - - - 1 2" 1/2" 18" - - - - - - - - - - - - - - KROWNE 17-108WL - o 27 1 SORTING SHELF - - - - - - - - - - - - - - - - - - - - - - - JOHN BOOS PB-SRW-42 - cn o W m 0 z' c=.� w w boo 28 - - - - - - - - - - - - - - - - - - - - - - - - - - - - 000000 29 1 BACK BAR REFRIGERATOR 8.8 - 1/2 115/1 SR - 14" - - - - - - - - - - - - - - - - - TRUE TBB-4PT - 30 1 UNDERBAR SINK - - - - - - - 1/2" 1/2" 14" - - 1-1/2" FS - - - - - - - - - - KROWNE 18-1C - 31 1 UNDERBAR HAND SINK - - - - - - - 1 2" 1/2" 14" 1-1/2" 12" - - - - - - - - - - - - KROWNE 18-18ST - > .Q - aa) � 32 1 WALK-IN 10.0 - - 120 1 JB - DFA - - - - - - - - - - - - - - - - - MASTER BILT 761010-X - _ N N 32.1 1 WALK-IN CONDENSER 15.0 - 3 4 208-230 1 - - - - - - - - - - - - - - - - - - - - MASTER BILT - � u �- cl) 32.2 1 WALK-IN EVAPORATOR - - - 115/1 JB - DFA - - - - - 3 4" FS - - - - - - - - - - MASTER BILT - - p` s co o co 00 33 1 WALK-IN - - - - - - - - - - - - - - - - - - - - - - - - MASTER GILT - - U � r 0 0 33.1 1 REFRIGERATION - - - - - - - - - - - - - - - - - - - - - - - - - - - 34 1 PASS-THRU ICE BIN - - - - - - - - - - - - 1/2" FS - - 1KROWNE KRPT-2436-10 - 35 1 UNDERBAR ICE BIN - - - - - - - - - - - - 1/2" FS - - - - - - - - - - KROWNE 21-30-7 - 36 1 1 BOTTLE COOLER 8.8 - 1/3 115/1 SR - 14" - - - - - - - - - - - - - - - - - TRUE TD-50-18 - z W W0 Q A B B R E VI A T 1 0 N S K E Y ELECTRICAL PLUMBING GENERAL APPLICATION 0 V VOLTAGE HW HOT WATER AFF ABOVE FINISHED FLOOR N I O T PH PHASE CW COLD WATER BFF BELOW FINISHED FLOOR I V AMP AMPERAGE DW DIRECT WASTE BTC BRANCH TO CONNECTION KW KILOWATT IW INDIRECT WASTE DFA DROP FROM ABOVE W HP HORSEPOWER G GAS Ct CENTERLINE MECHANICAL AND ELECTRICAL CONTRACTOR MUST CHECK OWNER'S PRESENT EQUIPMENT BEING RE-USED, SR SIMPLEX RECEPTACLE NAT NATURAL GAS NIC NOT IN CONTRACT EQUIPMENT SUBSITUTED FOR SPECIFIED TYPE OR MANUFACTURER OR THAT EQUIPMENT MARKED (BY VENDOR) = Z DR DUPLEX RECEPTACLE LP LIQUID PROPANE WHICH IS BEING SUPPLIED BY OTHERS SO THAT THE SERVICE REQUIREMENTS ARE CORRECTLY TYPED, o (,j,J QR QUAD RECEPTACLE BTU BRITISH THERMAL UNIT PROJECT PERSONNEL ADEQUATELY SIZED, & ROUGHED IN PROPERLY (LOCATION, HEIGHT & CONNECTION TYPE) SO AS TO C JB JUNCTION BOX S STEAM INLET ARCH ARCHITECT MINIMIZE THE AMOUNT OF MATERIALS & FITTINGS NEEDED FOR FINAL HOOK-UP RESULTING IN A NEAT AND G CP CORD & PLUG SR STEAM RETURN ID INTERIOR DESIGNER ORDERLY LOOKING JOB. a- DC DIRECT CONNECTION FS FLOOR SINK MEP MECHANICAL ENGINEERING FIRM ALL LABOR, SWITCHES, DISCONNECTS & FITTINGS REQUIRED FOR FINAL CONNECTION OF EQUIPMENT AS D MECHANICAL FD FLOOR DRAIN FSC FOODSERVICE CONSULTANT NECESSARY TO COMPLY WITH ALL CODES, INCLUDING ALL INTERWIRING TO BE FURNISHED BY ELECTRICAL 0 CFM CUBIC FEET PER MINUTE FFD FUNNEL FLOOR DRAIN KEC KITCHEN EQUIPMENT CONTRACTOR CONTRACTOR UNLESS STATED OTHERWISE. _ W FS STATIC PPRESSI WF WATER FILTER MW MILLWORK CONTRACTOR ALL LABOR, VALVES, TRAPS, TAILPIECES, STRAINERS, PRESSURE REDUCING VALVES, & FITTINGS REQUIRED �,.. c FS!; FIRE SUPPRESSION SYSTEM FOR FINAL CONNECTION OF EQUIPMENT AS NECESSARY TO COMPLY WITH ALL CODES, INCLUDING ALL INTER- C( co T R A D E S K E Y CONNECTIONS TO BE FURNISHED BY MECHANICAL CONTRACTOR UNLESS OTHERWISE STATED. z o U GC EC PC HVAC KEC MECHANICAL CONTRACTOR TO PROVIDE REMOVABLE 12" SECTION OF PIPE IN MAIN GAS SUPPLY LINE IN AN O w Q > W ACCESSIBLE AREA FOR INSTALLATION OF EITHER MECH. OR ELEC. CONTROLLED GAS SHUTOFF-VALVE, GENERAL ELECTRICAL PLUMBING HEATING,VENTILATION KITCHEN FURNISHED AS PART OF THE FIRE PROTECTION SYSTEM AND INSTALLED BY THE PLUMBING CONTRACTOR. 2 W -i CONTRACTOR CONTRACTOR CONTRACTOR & AIR-CONDITIONING EQUIPMENT CONTRACTOR CONTRACTOR < — z 0 w z C) w <C °° � as (D � �- O U 0 _ LLU) SCALE: NONE FS -2