Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DUNKIN DONUTS - FOOD - CLOSED
vDunkin Donuts r-6vf i 627 Main St. HY 001 7 Bellaire, Dianna From: CMG Reception <Office@coutomanagement.com> Sent: Tuesday, December 08, 2020 11:37 AM To: Bellaire, Dianna Cc: Kelly Shea Subject: RE: 1220 Iyannough Rd- Dunkin Donuts- Hyannis- 627 Main Street???? Importance: High Good Morning Dianna, Hope all is well! That's great news! As for the 627 Main Street location, it is closed permanently. Please advise if you will you need an official letter to confirm this or any other information in regards to the closure. Thanks, 560" q=4 Couto Management Group, LLC 169 Main Street Stoneham, MA 02180 P: 781-279-0290 F: 781-279-0360 office@coutomanagement.com ......,. . u..... From. Bellaire, Dianna [ma ilto:Dianna.Bellaire(a)town.barnstable.ma.us] Sent: Tuesday, December 08, 2020 11:26 AM To: CMG Reception Cc: Bellaire, Dianna Subject: 1220 Iyannough Rd- Dunkin Donuts- Hyannis- 627 Main Street???? Importance: High Hi, I received your passing frozen dessert report for this establishment and I will mail permit to the store today. I haven't heard if you are closing the Dunkin Donuts at 627 Main Street, Hyannis. I haven't received an application. Dianna Bellaire Permit Technician Town of Barnstable Health Division 200 Main Street Hyannis, MA 02601 P:508-862-4643 Fax:508-790-6304 1 's Town of Barnstable BOARD OF HEALTH John T.Norman Board of Health Donald A.Gaudagnoli,M.D. uA&NsfAum Paul J.Canniff,D.M.D. 200 Main Street, Hyannis, MA 02601 F.P. Thomas Lee Alternate Phone: (508) 862-4644 Fax: (508)790-6304 www.townofbarnstable.us Permit to Operate a Food Establishment In accordance with regulations promulgated under authority of 105 CMR 590.000 M.G.L. Chapter 94 Sections 305A, 3056, 146, 189 and 189A; Chapter 111, Sections 5 and 127A, a permit is hereby granted to: Permit No: 267 Issue Date: 01/01/2021 DBA: DUNKIN DONUTS #267 OWNER: CAPE COD ENTERPRISES LLC Location of Establishment: 627 MAIN STREET HYANNIS„ M 2 01 Type of Business Permit: FOOD SERVICE Annual: YES Seasonal: IndoorSeating: 17 Outdoor5eatin 0 n To ta Se g: 17 FIE S FOOD SERVICE ESTABLISHMENT: $250. 0 YE R: 2021 RETAIL FOOD: COTTAGE FOOD OPERATION: P mit Expires: 12/31/2021 B&B-FULL BREAKFAST: CONTINENTAL BREAKFAST: MOBILE-FOOD: MOBILE-ICE CREAM: Qn FROZEN DESSERT: Thomas A. McKean, RS, CHO, Health Agent FOR ESTABLISHMENTS WITH SEATING: PERMIT IS NOT VALID UNLESS ISSUED IN CONJUNCTION WITH A COMMON VICTUALER LICENSE Restrictions: MUST POST VARIANCE LETTER. Conditional Variance for one toilet facility with the following conditions: no seating authorized, onsite restroom shall be conveniently located and made easily available for employees. Restroom shall be kept free of boxes, mops, brooms, and any other large obstructions inconsistent with restroom use. Variance is non-transferable. Town of Barnstable BOARD OF HEALTH John T.Norman Board of Health Donald A.Gaudagnoli,M.D. BARN 13rAuLF. Paul J.Canniff,D.M.D. MAW 200 Main Street, Hyannis, MA 02601 F.P. Thomas Lee Alternate ak Phone: (508) 862-4644 Fax: (508)790-6304 www.townofbarnstable.us Permit to Operate a Food Establishment In accordance with regulations promulgated under authority of 105 CMR 590.000 M.G.L. Chapter 94 Sections 305A, 3056, 146, 189 and 189A; Chapter 111,Sections 5 and 127A, a permit is hereby granted to: Permit No: 267 Issue Date: 12/10/2019 DBA: DUNKIN DONUTS #267 OWNER: CAPE COD ENTERPRISES LLC Location of Establishment: 627 MAIN STREET HYANNIS, MA 02601 Type of Business Permit: FOOD SERVICE Annual: YES Seasonal: IndoorSeating: 17 OutdoorSeating: 0 Total Seating: 17 FEES FOOD SERVICE ESTABLISHMENT: $250.00 YEAR. 2020 RETAIL FOOD: COTTAGE FOOD OPERATION: Permit Expires: 12/31/2020 B&B-FULL BREAKFAST: CONTINENTAL BREAKFAST: MOBILE-FOOD: MOBILE-ICE CREAM: C,�/� FROZEN DESSERT: Thomas A. McKean, IRS, CHO, Health Agent TOBACCO SALES: FOR ESTABLISHMENTS WITH SEATING: PERMIT IS NOT VALID UNLESS ISSUED IN CONJUNCTION WITH A COMMON VICTUALER LICENSE Restrictions: MUST POST VARIANCE LETTER. Conditional Variance for one toilet facility with the following conditions: no seating authorized, onsite restroom shall be conveniently located and made easily available for employees. Restroom shall be kept free of boxes, mops, brooms, and any other large obstructions inconsistent with restroom use. Variance is non-transferable. 9- FIHE rok For Office Use Only: Initials: ` yo� Town of Barnstable _ ;K • Date Paid � Ariit Pd So�J(� 9�MARA ARA$� Inspectional Services t 1639. AfEo �' Public Health Division Check# . rr Thomas McKean,Director `jaD t — 200 Main Street,Hyannis,MA 02601 Office: 508-862-46444 Fax: 508-M-6304 APPLICATION FOR PERMIT TO OPERATE A FOOD ESTABLISHMENT DATE 11/14/19 NEW OWNERSHIP RENEWAL NAME OF FOOD ESTABLISHMENT: Cape Cod Enterprises, LLC DBA Dunkin' Donuts ADDRESS OF FOOD ESTABLISHMENT: 627 Main St., Hyannis, MA 02601 MAILING ADDRESS(IF DIFFERENT FROM ABOVE): c/o Couto Management Group, 169 Main St., Stoneham, MA 02180 E-MAIL ADDRESS: office@coutomanagement.com TELEPHONE NUMBER OF FOOD ESTABLISHMENT: 5( 08 J 771 - 1255 TOTAL NUMBER OF BATHROOMS: 2 WELL WATER:YES NO V ...(ANNUAL WATER ANALYSIS REQUIRED) ANNUAL: V SEASONAL: DATES OF OPERATION: / /_ TO NUMBER OF SEATS: INSIDE: 17 OUTSIDE: N/A TOTAL: 17 SEATING: MUST OBTAIN A COMMON VICTUALLER'S LICENSE FROM LICENSING DIV. ***OUTSIDE DINING RENIINDER*** OUTSIDE DINING,MUST BE APPROVED.BY THE HEALTH DIV.AND LICENSING AND MEET OUTSIDE DINING REQUIREMENTS. IS WAIT STAFF PROVIDED FOR OUTSIDE DINING? IS AN AIR CURTAIN PROVIDED AT WAITSTAFF SERVICE DOOR(S)? TYPE OF ESTABLISHMENT: (PLEASE CHECK ALL THAT APPLY BELOW) FOOD SERVICE RETAIL FOOD-ONLY required for TCS foods(foods requiring refrigeration/freezer) BED&BREAKFAST CONTINENTAL BREAKFAST COTTAGE FOOD INDUSTRY(formerly residential kitchen) MOBILE FOOD FROZEN DAIRY DESSERT MACHINES...(MONTHLY LAB ANALYSIS REQUIRED) j CATERING... (CATERING NOTICE REQUIRED BEFORE EVENT(SEE PAGE#2) TOBACCO SALES ... (ANNUAL TOBACCO SALES APPLICATION REQUIRED) I. *** SEASONAL,MOBILE &NEW FOOD ONLY*** REQUIRED TO CALL HEALTH DIV.FOR INSPECTION PRIOR TO PERMIT BEING ISSUED Q:Wpplication ForinsTOODAPPREV20.18.dot PLEASE CALL 508-862-4644 OWNER INFORMATION: FULL NAME OF APPLICANT Salvi Couto SOLE OWNER: YES NO D.O.B 3/7/1979 OWNER PHONE# 781-279-0290 ADDRESS 169 Main Street, Stoneham, MA 02180 CORPORATE OWNER:Cape Cod Enterprises,LLC FEDERAL ID NO. : 81-0559006 CORPORATE ADDRESS: 169 Main Street, Stoneham, MA 02180 PERSON IN CHARGE OF DAILY .OPERATIONS: . Elena Zasheva List(2) Certified„Food Protection Managers AND at least(1)Allergen Awareness Certified Staff All FOOD ESTABLISHMENTS must have 1 Certified Food Protection Manager PER SHIFT. "ATTACH COPIES OF CERTIFICATES**The Health Div.,will NOT use p years'ears records. You � must provide new copies and POST THE CERTIFICATES at your food establishment. Certified Food Managers Expiration Date Allergen Awareness Expiration Date 1.Elena Zasheva 6/ 20 /2022 I., Elena Zasheva 2 / 12 /2022 2. Mina Chattri 2 / 15 /2023 11 / 14 /2019 SIGNATURE OF APPLICANT DATE_ ***FOOD POLICY INFORMATION*** SEASONAL FOOD SERVICE:All seasonal food establishments,including mobile trucks must be inspected by the Health Div. prior to opening!! Please call Health Div.at.508-862-4644 to schedule your inspection. Please call at least(7)days in advance. FROZEN DAIRY,DESSERTS: Frozen desserts must be tested by a State Certified lab prior to opening and monthly thereafter, with sample results submitted to the Health Div. Failure to do so will result in the suspension or revocation of-your Frozen Dessert Permit.until the above terms are met. CATERING POLICY: Anyone who caters within the Town of Barnstable must notify theTown by fax or mail prior to catering event. You must complete a catering'notice found at http://www.townbfbarnstable.us/healthdivision/aliolications.a'sn. OUTDOOR COOKING: Outdoor cooking,preparation,or display of any food.product by a food establishment is prohibited. TOBACCO ESTABLISHMENTS: All tobacco establishments must complete an Application for Tobacco Sales Permit and Employee Signature Form. NOTICE': Permits run annually from January lst to Dec.3151 each calendar year. IT IS YOUR RESPONSIBILITY TO RETURN THE COMPLETED APPLICATION(S)AND REQUIRED FEES BY DEC 1 st. Q;\Applipition ForinMOODAPPREV2018.doc Py�p.NE rohti TOWN OF BARNSTABLE HEALTH INSPECTORS Establishment Name: Date: Page: of o OFFICE HOURS PUBLIC HEALTH DIVISION 8:00-9:30 A.M. BARNSTABLE. ' 200 MAIN STREET 3:30-a:3o P.M. Item Code C-Critical Item DESCRIPTION OF VIOLATION/PLAN OF CORRECTION Date Verified ,639• .e� HYANNIS, MA 02601 M$-8 -FRI.62-4644 No Reference R-Red Item PLEASE PRINT CLEARLY FOOD ESTABLISHMENT INSP CTION REPORT S08 Name Date at Tvoe of Type of Inspection O e Routine Addressomw Risk I d Service J Re-inspection Level Previous Inspection Telephone Residential Kitchen Date: Mobile Pre-operation 09 Owner HACCP Y/N Temporary Suspect 1 ss G Caterer eneral Compla' t Person in Charge(PIC) Tim � Bed&Breakfast 4 Inch./ } Other Inspector Out: I - L4- &-:� Each violation checked requires an explanation on the narrative page(s)and a citation of specific provision(s)violated. Violations Related to Foodborne Illness Interventions and Risk Factors(Red Items) Anti-Choking 590.009(E) ❑ Violations marked may pose an imminent health hazard and require immediate corrective Tobacco 590.009(F) ❑ Action as determined by the Board of Health. Allergen Awareness 590.009(G) ❑ FOOD PROTECTION MANAGEMENT ❑ 12.Prevention of Contamination from Hands ❑ 1.PIC Assigned/Knowledgeable/Duties ❑ 13.Handwash Facilities EMPLOYEE HEALTH PROTECTION FROM CHEMICALS ❑ 2.Reporting of Diseases by Food Employees and PIC ❑ 14.Approved Food or Color Additives ❑ 3.Personnel with Infectious Restricted/Excluded ❑ 15. Toxic Chemicals FOOD FROM APPROVED SOURCE TIME/TEMPERATURE CONTROLS(Potentially Hazardous Foods) ❑4.Food and Water from Approved Source ❑ 16.Cooking Temperatures ❑ 5.Receiving/Condition ❑ 17.Reheating ❑6.Tags/Records/Accuracy of Ingredient Statements ❑ 18.Cooling 7.Conformance with Approved Procedures/HACCP Plans ❑ 19.Hot and Cold Holding PROTECTION FROM CONTAMINATION ❑20.Time As a Public Health Control ❑8.Separation/Segregation/Protection REQUIREMENTS FOR HIGHLY SUSCEPTIBLE POPULATIONS(HSP) ❑9.Food Contact Surfaces Cleaning and Sanitizing ❑21.Food and Food Preparation for HSP- ❑ 10.Proper Adequate Handwashing CONSUMER ADVISORY ' , ' ❑ 11 Good Hygienic Practices ❑ 22.Posting of Consumer Advisories Violations Related to Good Retail Practices(Blue Items). Total Number of Critical Violations Critical(C)violations marked must be corrected immediately. (blue&red items) Corrective Action Required: ❑ No ❑ Yes Non-critical(N)violations must be corrected immediately or Overall Rating within 90 days as determined by the Board of Health. ❑ Voluntary Compliance ❑ Employee Restriction/Exclusion ❑ Re-inspection Scheduled ❑ Emergency Suspension C N Official Order for Correction:Based on an inspection today,the items ❑ Embargo ❑ Emergency Closure ❑ Voluntary Disposal ❑ Other: checked indicate violations of 105 CMR 590.000/Federal Food Code. 23.Management and Personnel (FC-2)(590.003) This report,when signed below by a Board of Health member or its agent A=Zero critical violations and no more than 3 non-critical violations. F=3 or more critical violations.9 or more non-critical violations, 24.Food and Food Preparation (FC-3)(590.004) constitutes an order of the Board of Health. Failure to correct violations regardless of the number of critical,results in an F. 25.Equipment and Utensils FC-4 590.005 B=One critical violation and less than 4non-critical violations g ( )( ) cited in this report may result in suspension or revocation of the food if no critical violations observed,4 to 6 non-critical violations=B. Seriously Critical Violation=F is scored automatically if: no hot 26.Water,Plumbing and Waste (FC-5)(590.006) establishment permit and cessation of food establishment operations. If C=2 critical violations and less than 9 non-critical. If no critical water,sewage back-up,infestation of rodents or insects,or lack of 27.Physical Facility (FC-6)(590.007) aggrieved by this order,you have a right to a hearing. Your request must violations observed,7 to 8 non-critical violations. If 1 critical refrigeration. 28.Poisonous or Toxic Materials (FC-7)(590.008) be in writing and submitted to the Board of Health at the above address violation,4 to 8 non-critical violations=C. 29.Special Requirements (590.009) within 10 days of receipt of this order. 30.Other DATE OF RE-INSPECTION: Inspector's Signature Print: 31.Dumpster screened from public view Permit Posted? Y N Grease Trap Previous Pumping Date Grease Rendered Y N #Seats Observed Frozen Dessert Machines: Outside Dining Y N PIC's Signature Print: Self Service Wait Service Provided Grease Trap Size Variance Letter Posted Y . N � ��CC� J o S m ' n e Dumpster Screen? Y N / Violations related to Foodborne Illness Violations Related to Foodborne Illness Interventions Interventions and Risk Factors(Red Items 1-22) and Risk Factors(Red Items 1-22) (Cont.) FOOD PROTECTION MANAGEMENT PROTECTION FROM CONTAMINATION PROTECTION FROM CHEMICALS 3-501.14(C) PHFs Received at Temperatures According to 1 590.003(A) Assignment of Responsibility* $ Cross-contamination 14 Food or Color Additives Law Cooled to 41°F/45°F Within 4 Hours* 590.003(B) Demonstration of Knowledge* 3-302.11(A)(1) Raw Animal Foods Separated from 3-202.12 Additives* 3-501.15 Cooling Methods for PHFs 2-103.11 Person-in-Charge Duties Cooked and RTE Foods.* 3-302.14 Protection from Unapproved Additives* 19 PHF Hot and Cold Holding Contamination from Raw Ingredients 15 Poisonous or Toxic Substances 3-501.16(B) Cold PHFs Maintained At or Below 41'F/45'F 590.004(F) EMPLOYEE HEALTH 3-302.11(A)(2) Raw Animal Foods Separated from Each 7-101.11 Identifying Information-Original Containers* 2 590.003(C) Responsibility of the Person-in-Charge to Other* g * 3-501.16(A) Hot PHFs Maintained At or Above 140°F* Require Reporting by Food Employees and Contamination from the Environment 7-202.11 Common Name-Working Containers 3-501.16(A) Roasts Held At or Above 130'F* 3-302.11(A) Food Protection** 7- 01.11 Separation-Storage* 20 Time as a Public Health Control 590.003 Responsibility of A Food Employee or An 7-202.11 Restriction-Presence and Use* * (� P y3-302.15 Washing Fruits and Vegetables 3-501.19 Time as a Public Health Control Applicant To Report To The Person In Charge* 7.202.12 Conditions of Use* 3-304.11 Food Contact with Equipment and Utensils* 590.004(11) Variance Requirements 590.003(G) Reporting by Person in Charge* Contamination from the Consumer 7-203.11 Toxic Containers-Prohibitions* 3 590.003(D) I Exclusions and Restrictions* 3-306.14(A)(B)Resumed Food and Reservice of Food* 7-204.11 Sanitizers,Criteria-Chemicals* REQUIREMENTS FOR 590.003(E) I Removal of Exclusions and Restrictions Disposition of Adulterated or Contaminated 7-204.12 Chemicals for Washing Produce,Criteria* HIGHLY SUSCEPTIBLE POPULATIONS(HSP) Food 7.204.14 Drying Agents,Criteria* 21 3-801.11(A) Unpasteurized Pre-Packaged Juices and FOOD FROM APPROVED SOURCE 3-701.11 Discarding or Reconditioning Unsafe Food* 7-205.11 Incidental Food Contact,Lubricants* Beverages with Warning Labels* 4 Food and Water From Regulated Sources g Food Contact Surfaces 7-206.11 Restricted Use Pesticides,Criteria* 3-801.11(B) Use of Pasteurized Eggs* 590.004(A-B) Compliance with Food Law* * 3-801.11(D) Raw or Partially Cooked Animal Food and 4-501.111 Manual Warewashing-Hot Water 7.206.12 Rodent Bait Stations * 3-201.12 Food in a Hermetically Sealed Container* Sanitization Temperatures* Raw Seed Sprouts Not Served Pe 7-206.13 Tracking Powders,Pest Control and 3-801.11(C) Unopened Food Package Not Re-Served* 3-201.13 Fluid Milk and Milk Products* 4-501.112 Mechanical Warewashing-Hot Water Monitoring* 3-202.13 Shell Eggs* Sanitization Temperatures* TIME/TEMPERATURE CONTROLS 3-202.14 Eggs and Milk Products,Pasteurized* 4-501.114 Chemical Sanitization-Temp.,pH. 16 Proper Cooking Temperatures for PHFs CONSUMER ADVISORY 3-202.16 Ice Made From Potable Drinking Water* Concentration and Hardness* 3-401.11A(1)(2) Eggs-155'F 15 sec dness* 22 3-603.11 Consumer Advisory Posted for Consumption of Animal Foods That are Raw,Undercooked or 5-101.11 Drinking Water from an Approved System* 4-601.11(A) Clean Utensils and Food Contact Surfaces of Eggs-Immediate Service 145°F 15 sec* Equipment* Not Otherwise Processed to Eliminate 590.006(A) Bottled Drinking Water* 3-401.11(A)(2) Comminuted Fish,Meats&Game Pathogens* E//d-11112001 4-602.11 Cleaning Frequency of Utensils and Food Animals-155°F 15 sec* 590.006(B) Water Meets Standards in 310 CMR 22.0* Contact Surfaces of Equipment* 3-302.13 Pasteurized Eggs Substitute for Raw Shell Shellfish and Fish From an Approved Source 3-401.11(B)(1)(2) Pork and Beef Roast-130°F 121 min* Eggs* 4-702.11 Frequency of Sanitization of Utensils and Food 3-401.11(A)(2) Ratites,Injected Meats-155'17 15 sec* 3-201.14 Fish and Recreationally Caught Molluscan Contact Surfaces of Equipment* Shellfish* 4-703.11 Methods of Sanitization-Hot Water and 3-40 1.11(A)(3) Poultry,Wild Game,Stuffed PHFs SPECIAL REQUIREMENTS 3-201.15 Molluscan Shellfish from NSSP Listed Stuffing Containing Fish,Meat,Poultry or 590.009(A)-(D) Violations of Section 590.009(A)-(D)in cater- F Chemical* Ratites-165' 15 sec* Sources* ing,mobile food,temporary and residential 10 Proper,Adequate Handwashing 3-401.11 C 3 Whole-muscle,Intact Beef Steaks 145°F* kitchen operations should be debited under Game and Wild Mushrooms Approved By 2-301.11 Clean Condition-Han Arms* Hands and A * ( )( ) P Regulatory Authority 3-401.12 Raw Animal Foods Cooked in a Microwave the appropriate sections above if related to 3-202.18 Shellstock Identification Present* 2-301.12 Cleaning Procedure* 165'F* foodborne illness interventions and risk factors. 590.004(C) Wild Mushrooms* 2-301.14 When to Wash* 3-401.11(A)(1)(b) All Other PHFs-145'F 15 sec* Other 590.009 violations relating to good retail 3-201.17 Game Animals* 1 11 Good Hygienic Practices 17 Reheating for Hot Holding practices should be debited under#29-Special Requirements. 5 Receiving/Condition 2-401.11 1 Eating,Drinking or Using Tobacco* 3-403.11(A)&(D) PHFs 165°F 15 sec* 3-202.11 PHF's Received at Proper Temperatures* 2-401.12 Discharges From the Eyes,Nose and Mouth* 3-403.11(B) Microwave-165'17 2 Minute Standing Time* VIOLATIONS RELATED TO GOOD RETAIL PRACTICES * 3-301.12 Preventing Contamination When Tasting* * (Blue Items 23-30) 3-202.15 Package Integrity g 8 3-403.11(C) Commercially Processed RTE Food-140°F Critical and non-critical violations,which do not relate to the foodborne 12 Prevention of Contamination from Hands g illness interventions and risk factors listed above,can be found in the 3-101.11 Food Safe and Unadulterated* 3-403.11(E) Remaining Unsliced Portions of Beef Roasts* 6 Tags/Records:Shellstock 590.004(E) Preventing Contamination from Employees* 1g Proper Cooling of PHFs following sections of the Food Code and 105 CMR 590.000 3-202.18 Shellstock Identification* 13 Handwashing Facilities 3-501.14(A) Cooling Cooked PHFs from 140°F to 70°F 3-203.12 Shellstock Identification Maintained* Conveniently Located and Accessible Within 2 Hours and From 70'17 to 41'F/45'F Item Good Retail Practices FC 590.000 Tags/Records:Fish Products 5-203.11 Numbers and Capacities* Within 4 Hours* 23. Management and Personnel FC-2 .003 3-402.11 Parasite Destruction* 5-204.11 Location and Placement* 3-501.14(B) Cooling PHFs Made from Ambient 24. Food and Food Protection FC-3 .004 3-402. 5-205.11 Accessibility,Operation and Maintenance Temperature Ingredients to 41'F/45°F 25. Equipment and Utensils FC-4 .005 Records,Creation and Retention■ Within 4 Hours* 26. Water,Plumbing and Waste FC-5 .006 590.004(J) Labeling of Ingredients* Supplied with Soap and hand Drying Devices 27. Physical Facility FC-6 .007 7 Conformance with Approved Procedures/ 6-301.11 Handwashing Cleanser,Availability 28. Poisonous or Toxic Materials FC-7 .008 HACCP Plans 6-301.12 Hand Drying Provision 29. 1 Special Requirements 009 3-502.11 Specialized Processing Methods* 30. 1 Other 3-502.12 Reduced-Oxygen Packaging Criteria* 8-103.12 lConformance with Approved Procedures* S:590Formback6-2doc *Denotes critical item in the federal 1999 Food Code or 105 CMR 590.000. *Denotes critical item in the federal 1999 Food Code or 105 CMR 590.000. ADDRESS .- !RE `IEWED FOR DESIGN CONFORMANCE ONLY I APPROVAL FOR THESE PLANS BY ALLIED DOMECQ DOES NOT IMPLY THAT 621 MAIN STREET ® /- I ALL IED DOMECQ HAS REVIEWED THEM FOR CONFORMITY TO APPLICABLE � CODES OR REGULATIONS toolE>VAIJ I 0APPROVED H1 ANNIS , MA 02601 � :A, _ I C1 APPROVED AS NOTED: Submit Record Copy for Archives 0 DISAPPROVED AS NOTED: Revise and Resubmit �' 0 -E)- 0 INCOMPLETE INFORMATION: Add requested informaiton and resubmit � D �F� L�\j OWNER ® _ Date: ALLIED M QSR S A L V I C O U T O Construction ctian Manager o I Notes: D o C /`0 DUNKIN ' DONUTS LNJ 169 MAIN STREET S -ON EH AM , MA 02180 ABBRE IATION INDEX INDEX OF DRAWINGS ADA STATEMEN T� BUILDING DATA - MASSACHUSETTS �.-ANti GA.« GAUGE� Q.T. QUARRY TILE USE GROUP: BUSINESS ?? AT. GALV. GALVINIZED QTY. QUANTITY sun A/C AIR CONDITIONING GYP. BD. GYPSUM, BOARD R.A. ALLIED DOMECQ TYPE OF CONSTRUCTION: TYPE 5Blaw � I A.0 AREA DRAIN HDWD. HARDWOOD RAD. RADIUS T1 TITLE SHEET/ ARCHITECTURAL DATA I HEREBY CERTIFY THAT THE PLANS AND DRAWINGS (0 I " A.F.F. ABOVE FiNiSH FLOOR HDR. HEADER REF. REFRIGERATOR FOR THIS PROJECT WERE DRAWN IN ACCORDANCE STORIES: 1 ® � I T1 .1 GENERAL NOTES; �� I � I ALUM. ALUMINUMH.L . HOLLOW METAL REINF. REINFORCING NATIONAL ACCOUNT INFO WITH ALL FEDERAL, STATE AND LOCAL LAWS, ALLOWABLE FLOOR AREA: 4200 S.F. 00M04 I (D �I I ALA. ALTERNATE Iln�ai HORIzaNTAL RED. RECISION ACTUAL FLOOR AREA: 1370 S.F. L; i INCLUDING BUT NOT LIMITED TO, THE AMERICANS APPROX. APPROXIMATE HGT. HEIGHT REQ'D REQUIRED LEGEND; DOOR SCHEDULE WITH DISABILITIES ACT (THE "ADA") i L3L)• BOARD I.D. INSIDE DIAMETER RESIL RESILlANT Al FLOOR PLAN; THE ADA m ® co BL'?G. BUiL.DIN INSU' INSULATION RM. ROOD A1 .1 DEMOLITION PLAN; PARTITION PLAN; LEGEND ACCESSIBILITY GUIDELINES, M ASSACH U SETTS o � 0 I3M. BEAM INT. INTERIOR R.O. ROUGH OPENING A2 REFLECTED CEILING PLAN; LEGEND; DETAILS OCCUPANCY LOAD: � I PSMT, B. EMENff JT. JOINT SCHED. SCHEDULE 521 CM R, AND ANY OTHER LOCAL REGULATIONS < z x A3 FLOOR TILE PLAN; DETAIL; SCHEDULE m ® a UT�104. BETWEEN KIT. KITCHEN SEC. SECTION OR STAND DS. FIXED SEATS: 0 PERSONS � u- BOT. BOTTOM LAM. LAMINATE S.F. SQUARE FOOT A4 INTERIOR ELEVATIONS C.L. CENTER LINE L.AV.. LAVATORY SHT. SHEET A5 EXTERIOR ELEVATIONS (� EMPLOYEES: 5 PERSONS C.T. CERAMIC 11LE LT. LIGHT SIM. SIMILARDate: �'�� �S CLG. CEILING MAS. MASONRY SPEC. SPECIFICATION ARCHITECT'S "RE7--HERE TOTAL OCCUPANCY: 5 PERSONSIq CLOS. CLOSET MAX. MAXIMUM SQ. SQUARE K1 EQUIPMENT PLAN; ELEVATIONS; SCHEDULE CM CONSTRUCTION MGR. MECH. MECHANICAL S.S. STAINLESS STEEL CMU CONC. IMASONRY UNII MTL. METAL STD. STANDARD K2 EQUIPMENT SCHEDULE COL. COLUMN MM. MANUFACTURER STL. STEEL ALLIED DOMECQ REFERENCES CONC. CONCRETE MIN. MINIMUM STRUCT. STRUCTURAL CONT. CONTINUOUS Misc. MISCELLANEOUS SUSP. SUSPENDED E1 ELECTRIC LIGHTING PLAN; ALLIED DOMECQ SPECIFICATION BOOK FLAME SPREAD: CONST. CONSTRUCTION I .O. MASONRY OPENING TEL TELEPHONE E2 ELECTRIC POWER PLAN; ELECTRIC SS FREEZER CORE MATERIAL: 25 DEPT. DEPARTMENT MTD, MOUNTED THK. THICK PANELBOARDS; ELEVATION; LEGEND (ISSUED 1 /31 /98) I DTL DETAIL N.I.G. NOT IN CONTRACT THRU THROUGH I D.F. DRINKING FOUNTAIN NO. NUMBER T.O.P. TOP of PLATE E3 LOW VOLTAGE PLAN; LEGEND; SCHEDULE NATIONAL ACCOUNT SOURCE FREEZER METAL PANEL: 25 I DIAMETER T.O.S. TOP OF STEEL I DA. N.T.S.. NOMINAL INFORMATION BOOKLET I DIM. DIMENSION N.T NOT TO SCAM T.O.SL. TOP OF SLAB �DISP. DISPENSER O.A. OVERALL TRT. TREATED P1 PLUMBING PLAN; RISER DIAGRAM; LEGEND; NOTES SMOKE DEVELOPMENT RATINGS: ON DN. DOWN O.C. ON CENTER TYP. TYPICAL P2 PLUMBING PLAN; RISER DIAGRAM; LEGEND; NOTES (ISSUED 3/6/00) FREEZER CORE MATERIAL: 250 DR. DOOR O.D. OUTSIDE DIAMETER V.C.B. VINYL. COMPOSITION BASE D.S. DOWN SPOUT OPNG. OPENING V.C.T. VINYL COMPOSITION TILE P3 PLUMBING DETAILS ALLIED DOMECQ EQUIPMENT FREEZER METAL PANEL: OVER 500 DWG, DRAVnNG OPT. OPTIONAL VERT. VERTICAL SPECIFICATION B I N D E R EA. EACH PL.. PLATE V.I.F. VERIFY IN FIELD BASED ON THE FOLLOWING CODES s EL. ELEVATION P.LAM. `PLASTIC LAMINATE V.W.C. VINYL WALL COVERING LO ELEC. ELECTRICAL PLUMB. PLUMBING W/ WITH (ISSUED 6 /97) COMMONWEALTH OF MASSACHUSETTS BUILDING CODE Uj I EQ. EQUAL. P L_YWD. PL`t'WOOD W.C. WATER CLOSET EQUIP. EQUIPMENT PR. PAIR WD. WOOD 1999 FDA FOOD CODE 780 G.M.R. - 11 /27/98 X I EXIST. EXISTING PROP. PROPERTY W/O WITHOUT (ISSUED 19 9 9) 7— '� EXT. EXTERIOR P.S.F. PER SQUARE FOOT Vi'. WATERPROOFING ® M F.D. FLOOD DRAIN P.S.I. PER SQUARE INCH WT. WEIGHT ALLIED DOMECQ �'FIN. FINISH PTD. PAINTED W`WM. WELDED WIRE MESH DATA I FIL. FLOOR P.V.C. POLY VINYL CHLORIDE W I.— F.O. FACE OF Fr. FOOT SiGNAGE DRIVE-THRU: v < F URN. FURNITURE SQUARE Uj Z TYPE FOOTAGE DIMENSIONS YES/NO NO PYLON /MONUMENT 40 S.F. 4'-3 1 /2" x 9'-3 3/4" NUMBER OF D.T. WINDOWS . I BUILDING 40 S.F. CHANNEL LETTER SIGN MENU BOARD SIZE CAR LENGTHS FROM D.T. WIN. STACKING (# OF VEHICLES) I GRAPHIC SYMBOLS ESCAPE LANE < SECTION NUMBER FINISH NUMBER FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS FOR INTERIOR WALL AND STORE DIMENSIONS: DRIVE THRU TIMER SYSTEM CEILING FINISH MATERIALS, INTERIOR FINISH CLASSIFICATION: III 76-200 : SQ. FOOTAGE < 202 P-z� � � ) _ SHEET NUMBER MATERIAL FLAME SPREAD SMOKE SALES AREA/ PUBLIC AREAS/ TOILETS 630 S.F. RESTROOMS: w 0 SECTION FINISHES RATING DEVELOPMENT NUMBER W -- RETAIL/SERVICE 330 S.F. ^ DETAIL NUMBER FIBERGLASS REINFORCED PANELS 175 135 HANDICAP RESTROOMS 1 e I- � DETAIL H1 VINYL WALL COVERING 5 5 PREP AREA 410 S.F. 0 301 PLASTIC LAMINATE 30 200 —' < I SHEET NUMBER ENAMEL PAINT ON TRIM, DOOR 5 BASEMENT (NO WORK) N/A C) :2 �--- DETAIL FRAMES, WOOD SHELVING SECOND FLOOR (NO WORK) N/A � LLJ �- �--- - 1 a WOOD STAIN NATURAL WOOD SURFACES 5LLJ I DOOR MARK PARTITION KEY TOTAL: 137C S.F. �--------- CLEAR SEALER NATURAL WOOD DOORS 5 ACCOUSTICAL CEILING TILES 23 (� �J SEATING:# � DOOR PARTITION TYPES OF TABLES 0 TABLES LL_9 C) D100 STAND-UP COUNTER 1 EQUIPMENT TAG COLUMN REFERENCE GRIDS STOOLS 0 < # OF HANDICAP SEATS 0 SHEET 0 OR DRAWING NOTES INTERIOR ELEVATION INDICATOR TOTAL # of SEATS 0 SEATS FILE#:300331 , D05076 DATE:10/3/05 , PROD. MGR. J.R. C.M. B. FLANNERY i NOTE: GENERAL NOTES FOR COMPLETE NATIONAL ACCOUNT SOURCE INFORMATION, REFER TO LATEST ALLIED DOMECQ NA11ONAL ACCOUNT SOURCE INFORMATION 1. GENERAL CONTRACTOR SHALL REFER TO WRITTEN SPECIFICATIONS FOR BOOKLET (INFO ALSO AVAILABLE ONLINE CAD www.adrus.com/extranet). � - - ADDITIONAL INFORMATION NOT CONTAINED IN THE DRAWINGS. NOTE:2. GENERAL CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING AT SHELVING, CY NOTE: 3 COMPARTMENT SINK, T & S SPRAY BRACKET, POT RACK, HAND SINKS, MOP CONTRACTOR TO IDENTIFY ONESELF AS WORKING WITH ALLIED DOMECQ u TOILETS HAVE BEEN DESIGNED TO COMPLY SINK, FAUCETS, TIME CLOCK, GRAB BARS, LAVATORIES, HAND DRYERS, MIRRORS, WHEN ORDERING FROM NATIONAL ACCOUNTS. 0 o WITH ALL APPLICABLE STATE AND A.D.R. PAPER TOWEL DISPENSERS, SOAP DISPENSERS, OTHER ACCESSORIES, ETC. REGULATIONS. 3. REFER TO THE 'K' DRAWING(S) FOR INFORMATION REGARDING THE EQUIPMENT �--- - - ----- - �- - - m m AND EQUIPMENT LAYOUT. mU( 4. GENERAL CONTRACTOR SHALL INSTALL 2"x8" BLOCKING FOR SANDWICH STATION, ACOUSTICAL CEILING TILE & GRID (ALL REGIONS): EIFS: UTILITY IES DRYVIT z Z STORAGE TOP OF BLOCKING ® 4'-4" A.F.F. ALSO BLOCKING FOR VDU MONITORS. ARMSTRSHERRY®NG BRUN®or�PHYLLIS�MIW_R BOB WALTERSDORF CSI Ec� EZ3 5. ALL TOILET WALLS AND OFFICE WALLS TO HAVE ALUMINUM FACED FIBERGLASS -- - ----- INSULATION. T. 1-800-442-4212 N.E. SALES MANAGER 0 6. HANDICAP REQUIREMENTS: F_: bpo-strategic-accounts0ormatrong.com T: (860) 285-8341 THE GENERAL CONTRACTOR WILL ACQUAINT HIMSELF WITH THE HANDICAP REFERENCE: AWED DOMECQ S STRATEGIC ACCOUNT F: (860) 285-8347 2 �- ROBERT WIWAMS-ACCOUNT REP. � REQUIREMENTS OF THE APPLICABLE STATE AND THE AMERICAN DISABILITIES ACT robertw®dryvit.com a� ELECTRIC PANEL (ADA) AND INSURE THAT THIS FACILITY WILL BE ACCESSIBLE. THE FOLLOWING T: 717-397-7879 OR 717-917- 7103 www.dryVt.com -- 4� CY N 3 IS A PARTIAL LIST OF REQUIREMENTS: E: RDWilliamsc�armstrong.com a�C 1. AISLES MINIMUM 36" WIDE. SALES AREA FLOOR 11LE: LAMINATE: 2. CURB CUTS PROVIDED AT HANDICAP PARKING SPACES. GJ- _ 3. MAX. SLOPE OF 5% OR 1:20 IN ALL PARKING LOTS AND ON SIDEWALKS, FORMICA ---- --- �-, CHOICE OF DISTRIBUTORS: - _ TOM KELLER-SPEC SLS REP IL ALL OTHER AREAS WITH GREATER SLOPE WILL BE CONSIDERED A RAMP. NORTHEASTMIDWEST T (508) 746-7822 4. SIDEWALKS WILL BE A MINIMUM OF 4'-0" WIDE. SHEP BROWN ASSO®RANN CLAY PRODUCTS; C: (617) 201-3917 , 5. RAMPS HAVE TO HAVE A MAXIMUM SLOPE OF 1;12 WITH HANDRAILS AT DAVID HOFFMAN KIM KAUFMAN tom.keller*formica.com 34" AND 19" ABOVE THE FLOOR ON BOTH SIDES AND TO EXTEND T. 781 935-8080 T 708 422-1000 ^�S �m OC ERS I 1 7'-7" STAND ' » ( ) ( ) MIKE VENTURI- x ENTRANCE TO I COMPA TM ICE W/ HAND BEYOND THE TOP AND BOTTOM OF THE RAMP A MINIMUM OF 1 -6 . F: (781) 935-209OF: (708) 38:5-1047 USA CONTACT FOR STOCK AVAILABILITY / b EXISTING 2ND 1 DRAINB AR[ SINK 150 LB 6 (PULL) SS WILL HAVE A IDE OF THE DOOR.MINIMUMEXCEPT IN CERTAIN STATES WHERE HT z z FLOOR � � � � I I BIN ( ) � » ( WESTCOAST SOUTHEAST M (.Ven 786-3435 Mike.Venturi*formica.com 1 z R E VE ° 1 WILL BE 2-0 ). DSA, INC. DSA, INC. v ' o I I 11 0 SAMPLES: 1-800-FORMICA �" � 7. DOOR MATS AND THRESHOLDS TO BE A MAXIMUM OF 1/2 HIGH. FELLY HERNANDEZ CHRISTIAN ZINKL-REP 3 8. DOOR HARDWARE SHALL BE MOUNTED BETWEEN 36" AND 42" ABOVE T. (714) 774-7750 T: (770) 442-5500 to m Boa THE FLOOR. F: (714) 774-7122 F: (770) 442-5502 KITCHEN SWING DOOR: r r U 9. DOORS TO HAZARDOUS AREAS TO HAVE KNURLED HANDLES. E: christion.zlnkl®dso-ceramics.com a OFFICE---� �flr ,0 3Z336i 3Z3323 ° ' o o 10. T OILETS: ELIASON CORPORATION - __ . U) a x s ® " I A. LAVATORY TO HAVE LEVER HANDLES, SPRING FAUCETS OR SELF DOOR SALES FOR ORDERS c�z Za 'm SERVICE AREA KITCHEN FLOOR TILE: 00 ° I iv�w�wo:� 'c� ' METERING FAUCETS. T: (800) 828-3655 - Ly - 4 (n ��ow I ' ' ' ° " METROPOLITAN CERAMICS t to 0 - - wzv B. A COAT HOOK 54 ABOVE THE FLOOR WILL BE MOUNTED ON THE F: (800) 828-3577 co ® rr' - 0 2®�-, BACK SIDE OF THE HANDICAP STALL DOOR. TERRI CHASTAIN-DISTRIBUTION doors®eliasonco com M "� T01I T -- JCL , I U' �_ �' I C. LOCATE THE WATER CLOSET 18" FROM THE CENTER LINE OF THE T. (888) 325-3945 DIANE OGASIAN REP VP r 00 TOILET--" w 18 BSKTS ' 24 BASIN / � ° I w I 1a° r�Nw " " E: terri®ironrock.com M Q ! 00 „•�_�� ! B KE Y A R $ BSKTS �i i--� I f� zV) FIXTURE TO THE WALL. THE SEAT WILL BE 17 TO 19 ABOVE THE T: (860) 653-1725 b` DONUTS DONU, I I I/ (n Br ¢�� FLOOR TO THE TOP OF SEAT. ELLEN YOSSARIAN-SALES MGR. F: (860) 653-1702 3 _ �D I I D. PROVIDE TWO 42" LONG x 1 1/2" OUTSIDE DIAMETER PENNED GRAB T. (603) 942-8787 eliasondiane®earthlink.net ,- V j C14BARS, 1 1 2" FROM THE WALL WITH ONE BEHIND AT 6" FROM THE E: eyossarian®ironrock.com w �U WALL AND ONE ADJACENT TO AT 12" FROM THE WALL 33"-36" ° m mob000 € INK PARALLEL TO AND ABOVE THE FLOOR. WHEN A TANK PREVENTS WALL COVERINGS: F` uO 0 THIS LOCATION OF REAR GRAB BAR INSTALL GRAB BAR 3" ABOVE IN STORE TELEVISION AND SOUND SYSTEM: a in L TV ABOVE THE TANK. RIGHTER GROUP U) :E [� Z w .. I » T. 800-848-4841 HI-TECH SOUND (� Z X E. LAVATORY TO BE MOUNTED 32 ABOVE THE FINISHED 'FLOOR TO RIM 0Uri ` I '- " F: 800-391-1470 LIZ TALLON m WITH KNEE SPACE OF 30" IN WIDTH AND 27" IN CLEAR HEIGHT. + m UL 1'-0" F. INSTALL MIRROR 36" ABOVE THE FINISHED FLOOR (TO BOTTOM) AND DAVID NEE-ORDERS x 8341 T: (800) 649-4487 OR (508) 624-7479 fir, Y 6'-6» C F 5-0 COFFEE r� DneeCrightergroup.com F- (508) 460-7882 � � ��,��_ 11 COFFEE ICON FILLER 5-B`' CASH - 72 TO TOP. KEViN LYNCH-ORDERS x 8323 V` LL 4'-6" ___ i -- G. DISPENSERS TO BE MOUNTED A MAXIMUM OF 42" ABOVE THE FLOOR klynch@-ightergoup.com COMING SOON BANNERS: ' I I TO ALL OPERATING OR DISPENSING SLOTS. RUSS RYAN-REP x 8311 �' I I TAYLOR H. TOILET PAPER DISPENSERS MOUNTED 19 TO CENTER LINE ABOVE Cell: 978-697-3191 STRATO GRAFIX �. g o o I I 342 THE FLOOR. RR nORi hterGrou com DAVE MACE or BRIAN HEFFRON-ORDERSCUP ' 7 Eg 11. ACCESSIBLE PARKING SPACES, PASSENGER LOADIfIG ZONES, RAMPS, AND T. (800) 821-9948 OR 781-273-1530 "= "- z - SIGNAGE SHALL COMPLY WITH THE (ADA). SURFACE MATERIALS INC. F: (781) 272-7687 __ vz CBTP DISPLAY = 12, ON TOILET DOOR(S), SIGNAGE IS REQUIRED WITH RAISED LETTERS AND IN MARIANNE KELLY - brianhOstratografix.com r ¢ i BRAILLE INDICATING "UNISEX". MOUNT 5' CENTER AFF OPENING T. 800 231-3223 or 44A 24-8 0000 ext.128 STEVE CHUNIAS-SALES REP. �� REPLACE ALL I ( ) ( ) STOREFRONT WITH NEW SIDE OF DOOR. SIMILAR SIGNAGE REQUIRED IF BUTTONS PROVIDED. ID F: (800) 662-7890 �� 7. FURNISH ALL LABOR AND MATERIAL NECESSARY FOR THE COMPLETE ANNODIZtD ALUId11NUM 0 E: mariannek®sur-facematenals.c,�m FULL STORE WATER FILTRATION SYSTEM: '� C GLAZING AND 1" INSTALLATION OF CEMENT BOARD BACKING FOR F.R.P. AND CERAMIC TILL. . r INSULATED GLASS i �� SELF- TYPICAL SUBSTRATES FOR INTERIOR WALLS SHALL BE AS FOLLOWS: PAINT- BUNN-O-MATIC CORPORATION �-�` SERVE A. PREP AREA AND STORAGE AREAS: 0'-0" TO V-0": 5/8" DUROCK CEMENT DAN SHIELDS-ORDERS COOLER BOARD, V-0" & ABOVE: 5/8" PLYWOOD. TECHNICAL WILLIAMS T: (800) 646-2866 AREA TECHNICAL INFORMATION CONTACT: 800-321-8194 I S R �'II N G A L r B. SERVICE AREA: 5/8" MIN. PLYWOOD F: (800) 286-6339 COLOR SAMPLES CONTACT: 800•-382-6567 I C. SALES AND SEATING AREAS: GYPSUM BOARD MARK WEINER, ARCH. ACCT. EXEC. don.shields@bunnomatic.com *. SELF- 8. GENERAL CONTRACTOR TO PROVIDE FOR P.O.S SYSTEM AS SHOWN ON C: 617-438-1408 REFERENCE: CUSTOMER #323679 r - TRASH/TRAYS SERVE ELECTRICAL DRAWINGS OR, AT A MINIMUM THE FOLLOWING r:;ONDUITS; STEVE KARVUNIS-BUNN REP. COOLER A. 2 1/2" I.D. FROM 4 x 4 x 3 JUNCTION BOX LOCATED BEHIND OFFICE DESK 800-637-8606 OR UP WALL TO ABOVE CEILING. AWNING FABRIC: CELL: 217-306-3662 4 ABO B. FROM A HUB IN THE FRONT LINE CHASE UNDER SLAB TO BACK WALL 3M COMMERCIAL GRAPHICS DIVISION E: Steve.Karvunis0bunnomatic.com PROVIDE A 2 1/2" CONDUIT WITH 2'=0" SWEEPS AT ENDS. TERMINATE CINDY JENKINS JERRY FITZGERALD-CUNO REP. � ABOVE THE CEILING. (800) 444-8088 PRESS 1 630-554-6790 C. 2"x4" ELECTRICAL BOX 6'-0" A.F.F. WITH 1" CONDUIT IN WALL TO ABOVE E: ccjenkinsl®mmm.com CELL 630-886-3310 SALES AREA CEILING. CENTER 32"02"x3/4" PLYWOOD BLOCKING IN WALL FOR VDU UNIT. DEB GI AMPOLO-ACCOUNT REP. JFitzgerald0Cuno.com NOTE THAT THE MAXIMUM CONNECTION LENGTH BETWEEN A VDU(S) AND ITS T. 800-714-9865 OR (860) 298-8782 (NO SEATS) DEDICATED CPU IS 75'-0" AND ONE TELEPHONE JACK IN OFFICE TO BE AN djgiampolo®mmm.com CLICK & CLEAN DISPENSING SYSTEM ISDN LINE. NOTIFY DUNKIN' DONUTS IF NOT REGIONALLY AVAILABLE. & DERMA FOAM HAND SOAP DISPENSERS: 0 PERSONA KAY CHEMICAL COMPANY Q 1 9. NOTE: "P.O.S".. ALL POWER OUTLETS FOR P.O.S. DEVICES ARE ARLIENE BIRD EXISTING RAILING EXISTING RAND T: 800-843-9888 OR 605-882-2244 F: 800-843-9890 OR 605-882-3521 ® X TO REMAIN EXISTING LANDING DEDICATED CIRCUITS WITH THIRD WIRE ISOLATED GROUND. AN IG IS AN INSULATED LAURIE KOEHN-ORDERS NE CORPORATE ACCOUNTS MANAGER WIRE, SEPARATED FROM ALL OTHER GROUND WIRES, RUNNING BACK TO THE T; (800) 333-4300 X846 Cn Xi I BUILDING MAIN OR COMPLEX POWER PANEL. NEMA STANDARD L5-15R I.G. FOR Ikoehn@persono-inc.com JOEL WIWAMS-DIVISION MANAGER F: (973) 696-9383 Q RECEPTACLE AND PLUG. USE OF IG DUPLEX OR QUADPLEX OUTLETS: jwilliams®persono-inc.com C: (973) 699-8465 0 m I � (I.E., HUBBELL IG-5262, IG-5362 OR EQUIVALENT). arliene.bird®ecolab.com EXISTING RAIUNG 10.GC. SHALL NOT PROCEED WITH CONSTRUCTION UNTIL V.D.U. LOCATIONS ARE ARLON / SIGNTECH > z W TO REMAIN. VESTIBULE DETERMINED. 0 :3KEVIN MCKINLEY-NATIONAL ACCOUNT SALES LIGHTING FIXTURES: V) REPLACE ALI STOREFRONT-� 11. TRAINING MODULE IS MOBILE UNIT, COORDINATE UTILITY LOCATIONS AS NECESSARY. T. OFFICE: 843-388-1364, CELL: 843-412-1323 I_ (!D AND DOORS WITH NEW 12.EXISTING WATER HEATER TO BE REUSED krnekinley®arlon.com VILLA LIGHTING 0- ANNODIZED ALUMINUM 13.PLANS CALL FOR FIBERGLASS INSULATION IN WALLS. IT CAN BE KRAFT FACED IF ELAINE HALL-CUSTOMER SERVICEMELANIE HURLEY-ORDERS Q GLAZING AND 1" INSULATED COVERED WITH GYPSUM. OTHERWISE USE FOIL FACED. ALL CEILING INSULATION TO T. 800-854-0361 ext: 310 T. (800) 325-0963 GLASS. BE FOIL FACED. eholl®arlon.com F: (314) 531-8720 w 14.GENERAL CONTRACTOR TO VERIFY SIZE OF REACHIN COOLER(S) BEING USED AND melonieh®villalighting.com ALLOW SUFFICIENT SPACE. COOLER TO BE 54" HIGH WHEN NOT AGAINST A WALL. FRP PANELS: STEVE DEMARIAS-REP. --r-ul PLAN � 15.NOT USED MARLITE: T. (508) 668-3159 Z FLOOR i L_A N CUSTOMER SERVICE-ORDERS steve®villalighting.com 16.DIMENSIONS SHOWN ARE TO THE FACE OF FINISH. T: 330-364-7561 17.THESE PLANS ARE BASED ON MINIMUM AWED DOMECQ CORPORATE DESIGN NANCY TUCKER-REP SCALE: 1/4" = 1'-0" REQUIREMENTS. THE STRUCTURAL DESIGN, FOOTING DESIGN, ADA COMPLIANCE T: 781-341-2871 p. AND GENERAL BUILDING REQUIREMENTS HAVE BEEN EVALUATED TO MEET ALL ntucker0marlite.com ADA STATE AND LOCAL CODES. KEMLITE Li 18.IF BOLLARDS ARE REQUIRED, G.C. WILL PROVIDE 6" CONCRETE FILLED PIPE AT BOB KILBOURNE-ORDERS 7' MAX. SPACING LOCATIONS SHOWN ON SITE PLAN. 800 435-0080 X 8620 ALL BOLLARDS PRIMED (1) COAT, PAINTED (2) COATS WHITE. 'BOLLARDS 3`-0" REFERENCE: NPP PROGRAM 1/4" TEMPERED ABOVE GRADE AND SET IN CONCRETE TO AT LEAST 3'-0" BELOW GRADE. KEITH MCGRATH-REP 0 SAFETY GLASS 19.OWNER S MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING T. 302-449-0715 00 EXISTING HVAC EQUIPMENT AND MODIFYING AS REQUIRED BY NEW HEATING KMcGrathOkemlite.com < LJJ I S RT P ALL WALLS BACK TO C.M.U. AS r7 1 x & COOLING LOADS. SUBMIT SHOP DRAWINGS FOR ARCHITECT APPROVAL SH OkYN AND INSTALL 2x4's 0 16" MAIL a< BEFORE ORDERING EQUIPMENT OR BEGINNING WORK. g O.C., INSULATE FULL WALL WITH %I SLOT ® I.l u ALUMINUM FACED FIBERGLASS / � n Ld INSULATION, AND G.W.B. FINiSI-I PER OFFICE i ® > �� :SCHEDULE. 0 ONLY E . E t- I- � r`' QUEUE RAIL DETAIL ® z - - -- EXISTING WALL -.. _ TO BE REMOVED MIN. N Q __j EXISTING STUD WALL A. C >- CL � n L_ 2x4 OR 2x6 STUD WALL 0 16" O.C. .-� V l NEW STUD WALL . 2x4 OR 2x6 STUD WALL. 16" O.C. DOOR . TYP E S 0 < 0 1-- DOOR SCHEDULE LJ LL � MARK SIZE TYPE MATERIAL DOOR FIN. FRAME DETAIL THRESHOLD HARDWARE FRAME FINISH REMARKS NO. W x H INT EXT NO. SET N0. INT EXT 3'-0"x 7'-O"x „A„ ALUM. AND FACTORY ALUMINUM - ALUMINUM 1 34 _-� GLASS 1 FACTORY CLEAR ANODIZED SHEET 2 I 1 3/4x" 7-0 x »A» GLASS ALUM. AND FACTORY ALUMINUM - NONE 1 FACTORY CLEAR ANODIZED NOT USED -_ 1 " x 4 1 2" SPRING HINGE 3--•0 x 6-$ x " » SOLID CORE ST-21 HOLLOW 1 /2 / , 4 1 3 4" C BIRCH ST-23 METAL 1/A2 NONE #5 P-34 UNDERCUT 1/2" a I3'-O"x 6'-B'x »C» SOLID CORE ST-21 HOLLOW 1/A2 NONE #3 P-30 UNDERCUT 1/2" � �3/4�' .� BIRCH ST-23 METAL FILE.300331 , D0�076 DATE.10/3/05 NOTE; VERIFY ALL. DOOR SWINGS ON FLOOR PLAN PROJ. MISR. J.R. C.M. B. FLANNERY x 0 .9 a N e- i to 00 t 1 t 1 1 1 I i 6'-3 1 2" / d 11 —4 10—10' � 1'-0" a " " I i i e 1 1 q i i 8*-7� \ M to U) 00 in I (o r^j 1 1 NM d- i a ® 00 r, i \ toBEco p _ 00 �� N 3'-6 1/2" 5'-5" 14'-1" 10'-5 1/2" ® x Ljrco m0000 Q� 1 p n^ N z x p t p m Lb- p � a p i M I i 1 1 1 a 8'--11 1/2" 7'-6 1/2" 17'-0" I —.o Ti i M 1 +j p 1 b 111 E 1 II 1 1� 1 1 1 p I W {— p 1 Q pF'F7 i d x 111 i14' Ix O m Q Ld Lv V) fy � — DE OLI TI ON PLAN W PARTITION PLAN ® Z SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" s ROOF DECK ROOF DECK EXTERIOR WALL FINISH — bi SEE ELEVATION DETAILS 0 cy SUSPENDED CEILING OR a 1/2" GYPSUM BD. ON SUSPENDED CEILING OR J METAL SUSPENSION SYSTEM 1/2" GYPSUM BD. ON o SEE PLAN FOR LOCATION. r METAL SUSPENSION SYSTEM SEE PLAN FOR LOCATION. cry �-- 2X4 STUDS @ 16" O.C. —8 C.M.U. WALL Z UA O 1/2" GYP. BD. 2X4 STUDS ® 16" O.C. L1L-j ' ALL LOWER 1/2 SHEET CD TO BE CONSTRUCTED /W 1/2 GYP. BD. LJ ` DURAROCK W 1/2" AIR SPACE FLOOR FLOOR SHEET B A- A� i 01 WALL TYPES- SCALE: N.T.S. FILE :300331 , D05076 DATE:10/3/05 PROJ. MGR. J.R. C.M. B. FLANNERY LEGEND 10/03 NOTE: LIGHTING IN TOILETS) AND OFFICE IS TO BE SENSOR LIGHTING, VERIFY w/ OWNER. Al MET 2GR8-332A-120-ADV-EEX on 2 X 4 RECESSED FLUOR. W/ACRYLIC LENS o 8'-1 0" 8'-10" Al W/ GE F32TBSPX30 (3), 4' T8 32w, FLUORESCENT LAMP AC-22 AC-22 Al-F MET 2GR8-332A-120-ADV-EEX UTILITY ESTORAGE X 4 RECESSED FLUOR. W/ACRYLIC LENS, W/ FLANGE KIT FCS24WLI AlAl-F W/ GE F32T8SPX30 (3), 4 T8 32w, FLUORESCENT LAMP Al-P MET 2EP3GX332S361-120-ADV-EEX 21 2 X 4 RECESSED FLUOR. W/PREMIUM PARACUBE C Al-P W/ GE F32T8SPX30 (3), 4 T8 32w, FLUORESCENT LAMP E Al-PF MET 2EP3GX332S361-120-ADV-EEX Ci 2 X 4 RECESSED FLUOR. W/PREMIUM PARACUBE, W/ FLANGE KIT FCS24WU X Al-PF W/ GE F32T8SPX3O (3), 4' T8 32w, FLUORESCENT LAMP _ Al-PO MET 2EP3GX332S361-120-ADV-EEX-OAO ci 2 X 4 RECESSED FLUOR. W/PREMIUM PARACUBE Al-PO W/ GE F32T8SPX30 (3), 4' T8 32w, FLUORESCENT LAMP ----�--- -� Al Al Al A1•-POF MET 2EP3GX332S361-120-ADV-EEX-OAO EQ.1 EQ. I 2 X 4 RECESSED FLUOR. W/PREMIUM PARACUBE, W/ FLANGE KIT FCS24WU A1_F 1-PO W/ GE F32178SPX30 (3), 4' T8 32w, FLUORESCENT LAMP 0ll 1 X 40RECESSED EFLUOR. W/ACRYLIC SLENS 120-ADV-EEX-OAO ' W/ GE F32178SPX30 (2), 4' T8 32w, FLUORESCENT LAMP LO c, 0 32W ELECTRONIC AFLUOR. DOWNLIGHT? (LENS COVER OVER FOOD PREP) OFFI CE `� Al-P EQ. EQ. Al B W/ GE F32TBX/SPX30/A/4P (1), 32w TRIPLE TUBE BIAX FLUOR. LAMP o Al-PF C5 TTF DD1408K co M 12" FROSTED HANGING GLASS PENDANT 0� Mt TOI LET- -- a — Oc5 W/ PNS EFG23E28 (1), 23w FLUORESCENT W/ BALLAST LAMP e l r7 I 00 F1,32 " 0 TRACK HALO 2' � mC� I 4' & 8' LENGTHS 'o co N V-9 Al-P #L652P, L651 P, L650P, L901 P, L957P, L900P, L908P, L983N. X L TRACK AND PENDANT ADAPTERS FOR FIXTURES C5 & Dl o m � w Al-P I I D1 HALO L3240EP/MSP5234 U7 24" SURFACE TRACK MOUNT MENU FIXTURE W/ SAFETY LENS U) L� FC i iUAL 4' LOW TEMP FLUORESCENT FIXTURE PROVIDED WITH "PACKAGE uj m o < d° -P W Al-P COOLER UNIT"/ALL WIRING BY ELECTRICAL CONTRACTOR � U- H ALL --- "4sAWow PROFILE TWINTUBEuo�. wj CLEAR POLY LENS 8`-1 0" I 12'-4" 7'-8" N H(AW) W/ STANDARD DOUBLE-ENDED BI-PIN TYPE LAMP AC-25 Al-P m G HALO PM I Q 1-0G EXTERIOR WALL PACK W 175w1 METAL HALIDE EWA PO A3-PO -PO / I TYPE "H" FIXTURE, SURFACE MOUNTED "LITTLE INCH" SOLID FRONT I a O UNDER CABINET FLORESCENT TASK LIGHT FIXTURE; ROCKER SWITCH ALKCO CAT. NO. SF-116-RSW-FUSE, OR EQUAL :5 z ❑j J SLC 852V - LAMP INCLUDED RECESSED SOFFIT FIXTURE W/ 175 METAL HALIDE Al-P Al-P AlP o #Al-P TYPE "K" FIXTURE: INCANDESCENT PORCELAIN FIXTURESERVING AREA - o - " " FUL RANGE SPEAKERS - SPEAKERS RADIO SHACK B L 8° 10" S #40 1272 WITH WHITE ENAMELED GRILL #40 1225. AC-22 RUN WIRES TO OFFICE, VERIFY W/ OWNER. W. F 0 CEILING MOUNTED TELEVISION - VERIFY LOCATION WITH OWNER AND D.D. 1 1 _A4 *_X I TV CONSTRUCTION MANAGER Iwo W SUR CC2-V SALES AREA �SOW (1 OR 2) LAMP ADJUSTABLE HEAD EMERGENCY LIGHT, WITH SEALED LIGHT, I� WITH SEALED LEAD CALCIUM BATTERY, (WP) IF OUTDOOR WATERPROOF R It@ WALL SCONCE SLP 8340-15/9008-12 EQ. EQ. EXTERIOR GRAY WALL LIGHT W/ LENS AC-25 W/ GE 50PAR30/H/FL-25-130V (2) LAMP tom- A1-PF Q � �X X SUR LPX70RWH w LED EXIT W/ BATTERY M X z > <t AC MARS AIR CURTAIN - 800-421-1266 ® m � DRIVE-THRU MODEL #E48C/CH-3, REAR DOOR MODEL #E48CHS-3, WITH DOOR MICROSWITCH & HEATER SWITCH, FURNISHED BY - Z VESTIBULE MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR. > 0 m VC 1 2 3 4 5 6 VALUE COMBO & MENU BOARDS — � J P-30 HOOD/ FAN - FOR TOASTER OVER SANDWICH STATION IN SOFFIT w h GREENHECK SP-115, 150 CFM, 1690 RPM, 1.0 AMP, 75 WATT REFLECTED CEILING P L.AN CEILING MATERIAL SCHEDULE - CODE MATERIAL MANUFACTURER PRODUCT NO. DESCRIPTION HOOD/ FAN - FOR TOASTER OVER SANDWICH STATION IN CEILING AC-22 VINYL PANEL ARMSTRONG 870 WHITE PF-EP AREA SERVICE AREAS USE CAPTIVE-AIR 24" x 18" HOOD WITH 24"H, 150 CFM, D.V. FAN Z SCALE: 1/4" = 1'-0" TF-1 AC-23 CEILING GRID ARMSTRONG 7300 WHITE ALL AREAS AC-25 CEILING TILE ARMSTRONG 2767 WHITE PUBLIC AREAS TOILET EXHAUST FAN, NUT #8814, 100 CFM BATH FAN (�VUIEF-1 SEE DRAWING SHEET M1 FOR DETAILS P-30 PAINT SHERWIN WILUAMS SW 7006 EXTRA WHITE GLOSS KEF-l/ PREP AREA EXHAUST FAN(S) - FOR OVEN HOODS ST-21 FINISH SHERWIN WILLIAMS V84F82 OVER ST-23 O KEF-2 SEE DRAWING SHEET M2 FOR DETAILS ST-23 STAIN SHERWIN WILLIAMS SW-3112-K AUTUMN MAPLE ® TYPICAL SUPPLY DIFFUSER L_I__ 2" x 8" HEADER 2" x 8" HEADER _c EXHAUST FAN GRILLE FOR TEF#1 SCHEDULED FINISH ON SCHEDULED FINISH Iul O i " BACK WALL 1/2-GYPSUM BOARD Lo X „ 1/2-GYPSUM BOARD 2 x WOOD FRAMING �J ,n 0 �. 2" x WOOD FRAMING STUD FRAMING TO RECESSED (B) STRUCTURE ABOVE NOTE: VERIFY LOCA71ON WITH OWNER F_ (� FIXTURE OVER BEFORE INSTALLATION •• Lv R , SCHEDULED FINISH ON Z W WORK AREAS UNE OF TRUSSES ® F- SCHEDULED FINISH ON Nl 1/2"GYPSUM BOARD (T(P•) (J " 3" " THREADI=D RODS WOOD IT,1/2 GYPSUM BOARD HOLLOW METAL FRAME ELEV. 9 -6 _ U WITH COMPRESSION I I —__ _ ® � O HOLLOW METAL FRAME "� WITH COMPRESSION ANCHOR AND ADJUST- +* °`��'°' ACOUSTIC PANEL m 5 5 8 5 5/8 * CEILING"'7jST-2i / " ANCHOR AND ADJUST- " MENT SCREW OR HEAD JAM B MENT SCREW OR " H E A D JAMB 1 5/16 MAPLE MOULDING ST-23 Li ®--- 7 5/s ---- 1 - TYP G.W.B. WC-23 I- 7 5/ " . ., 1 DETAIL DETAIL 1/2" CDX PLYWOOD BEHIND GYP. BD. 0" SUSPENDED CEILING U 2 SCALE: 3/4"=1'--0" A 2 SCALE: 3/4"=1'-0" REFERENCE LINE FOR SOFFITS El EC OUTLET FOR SP a SPRINKLER - EXISTING TO REMAINLij CROSS-BRACING x TV MONITOR T.V. BY OWNER SP n SPRINKLER - NEW —J LLJ 00 UNISTRLT CHANNEL � 0 2" x 6" HEADER SCHEDULED FINISH ON ++ __ ELEV. 6'-10" = LL_I SP d SPRINKLER - DROPPED TO NEW CEILING HEIGHT Lij 2" x 4" BOTTOM 1/2-GYPSUM BOARD _ SUSPENDED CEILING SPRINKLER - RELOCATED FROM ST-21 SUSPENDED CEILING BRACKET AS I > - 2 >> 1 5/16" MAPLE MOULDING BRACKET AS MANUFACTURED BY SP r MANUFACTURED BY LUCASEY #ACM2030 G.W.B. P-30 ST-23 STUD WALL LUCASEY #ACM2030 SHEET AM I TENNIS WHITE FINISH PER INTERIOR ELEVATIONS ADDED 3/4" END FINISH PANEL USPENDED CEILING HEAD JAMB JAMB DISPLAY CASE CASEWORK 1 3 DETAIL. DETAIL. FILE :300331 , D05076 BACK 6 MOUNTING DETAIL FOR T. V.A SCALE: 3/4»=1'-0" A 2 SCALE: 3/4"=1'-0" 1j AR SOFFIT DETAIL DATE:10/3/05 A2 SCALE: 3/4 —1 —0 SCALE: 3/4"=1'-0" 2 RROJ. MISR. J.R. OPTIONAL C.M. B. FLANNERY .91 i 400 AMP T-22 T-22 SINGLE PHASE C SERVICE UTILITY STORAGE sWITCHNECT PANEL 1&2 I I I I I I I Ll I I I I I ! UP--- II I I I I I I I I i I SECURITY - EXISTING STORAGEWIRE MESH I WALLS II II II II II T�— !' II O�--EXISTING LALLY 0 ! OFFICE— ���� I��� COLUMN (TYPICAL) I I a a !I 00 ITOILET EXISTING HVAC I rm T-21 II 00g� 1 I ® W zs N Amok x II mQQ � ° Q Z j< EXISTING I °° UJ m® < WIRE MESH I ° C �-I A LL wALLs I 0 0 ! T-21 EXISTING MILK I I I mrX` TING SECURITY CHEST I SRELOCATED I o z ICE I ! ON FIRST FLOOR; >c o STORAGE 0 I Wrvi wM I H i Fl SERVING AREA ' T-22 I n�m EXISTING I m� 4' x 5' I -�i FREEZER I �qF 0....3ALES AREA I LINE OUT TO SITE SALES i EXISTING GREASE/WASTE T-21 I SEWERAGE TILE NOTES: + Q ® X 1. START POINT OF TILE PATTERN V) X 2. OMIT BASE BEHIND DISPLAY CASE. O m BASEMENT PLAN NO WORKS > ZUJ NOTE. VESTIBULE SCALE: 1/4" = 1'-0" Lli TILE CONTRACTOR TO INSPECT FLOOR E L 0 0 R TILE PLAN-FOR RESIDUE FROM PREVIOUS TENANTAND APPLY CLEANERS AS NECESSARYQ � FOR PROPER TILE ADHESION. SCALE: 1/4" = 1'-O" ® z z CERAMIC TILE BY G.C. QUARRY TILE BY G.C. T-21 T-22 FRONT LINE CASEWORK COVE BASE -COVE BASE STRAIGHT BASE 8-21 8-22 8-23 5"t • [� SALES x — PREP.AREA x SALES _H SERVING CD co w < 0 BASE BY EQUIPMENT F- I- A S` MANUFACTURER U c Q- L i Z Z m TILE BASE DETAIL ® � Lij < cJ� SCALE: 1"= 1'-O" I Zo 1 FLOOR FINISH MATERIAL SCHEDULE 0 I-- CODE MATERIAL MANUFACTURER PRODUCT NO. DESCRIPTION/REMARKS _ W B-21 TILE COVE BASE KEOPE SERIES: JAPURA 6" x 12" UNPOLISHED (DARK) B-22 TILE COVE BASE METROPOLITAN 507 PURITAN GRAY 6" X 6" B-23 TILE STRAIGHT BASE KEOPE SERIES: JAPURA 6" x 12" UNPOLISHED (DARK) SHEET G-21 GROUT LATICRETE #24 NATURAL GRAY — WITH T-22 G-22 GROUT LA11CRETE #45 RAVEN — WITH T-21 T-21 SALES FLOOR TILE KEOPE SERIES: JAPURA SERIES:JAPURA (®ARK)-12"x12" FILE :300331 , D05076 T-22 PREP AREA QUARRY TILE METROPOLITAN 507 PURITAN GRAY 6" X 6" DATEE:10/3/05 EF-22 EPDXY FLOORING STONHARD STONSHIELD HRI SAGE, STEEL GRAY, PEWTER, OR SLATE PROJ. MGR. J.R. G.M. D. FLANNERY PROVIDE DUPLEX RECEPTACLE IN CENTER 'VC' MENU BOARD SOFFIT FOR VALUE COMBO BOARD ON CASH STATIONS VDU ON THIS WALL � 27 1/2- 27 1/2-_ 49_9. 27 1/2- 27 1/2- TOASTER VERIFY LOCATION rST-21 122" -' 12" 12" 12" HOOD WITH OWNER. ® Q -223 O � WC-23 F` � �- r- -, F� -, TOP MULLIONS ONLY USED AT FRONT OF VESTIBULE .� FRP-23 i I MB I I MB A25[�I VC ! I MB ! ! MB FRP-23 a — M14 83 - M17n M13 2 FRP-23 RP-23 I \ I.C.B. I ESPRESSO ESPRESSO B18 --t B42r-- r---� �/ t� 0 1 ___ __ I.C. DISP. �-� IRO! I I ICRO! o_ ® ® t� " , " e I I r-i r� I I �=_L _ ate r — -- 't \ I x I I I I I I I I — _ x I x / / i UD p 1 -6 2-0 1 1 MAIN POS GROUPI I i i \\ 0 1817 I I I t I ! I ---- WARMER I " // p SINK FILLER I --� 19 I j d_®_L L11J --- F ------ I 9 -------I OMIT Whr-C-O IiC�G- r T -r - - I I N BEHIND CASE TO LINE - / ���®�� t° DELFIE , I I -r - ! I Itt It A19 A21 A23 I // I I I I r ICE I f I A 0 III _ �4 A28 tl \ ! I I I I I UCR 111 I !f C IIL---- ! Ill It P-30 [a]x Ill // I I I A26 I I I CADDY 11 ca �I�e _Irx-' ! ! I 1 / t I I III I I- L ---1y IL� _ II o ee e lu B-22 - LINE OF CASEWORK SANDWICH 3'-0" SLICER SLICER e ---� BEV. CTR. STATION BEV. CTR. PRINTER OMIT TILE BASE BEHIND DISPLAY CASE STATION STATION TOASTER ---- WC 23 INTO AROUND CORNER 6" BACK LINE ELEVATIONS INTO DISPLAY CASE AREA VESTIBULE ELEVATIONS T Y P . PAINT REMAINING P_3� SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" U) Em BACK LINE ELEVATION00 SCALE`: 1/4" = 1'-0" ® 00 n t) < I Do L � I LPO (0 � IA" ® PO mDO ® � °� LO Z U) li � w 5/4" Lu mo < MONOPOINT PENDANT LIGHT FIXTURE (C5). WC-25 CENTER ON GLAZING NOTE: SEE REFLECTED CEILING PLAN FOR P-341 PATCH AND REPAIR EXISTING —�-- ___�_ SPECIFICATIONS AND MOUNTING LOCATION. N TOP OF CHAIR r- WALL AS REQUIRED BEFORE wC-26 ST-21 APPLYING NEW FINISHES 2'110" A.F.F. ON WALL W/ WC-24 1/2" G.W.B. —SIGNAGE (MEN/WOMEN) WALL COVERING WC-23 OR WC-26 ADA ROOM IDENTIFICATION SIGN 5 1 2" LO WC-23 WC-23 / / �� LATCH SIDE OF DOOR)) MAPLE CHAIR RAI MAPLE CHAIR RAIL Z STAIN ST-23 ST-21 c t CHAIR RAIL I o CHAIR RAIL i/ ST-23 AND 3 COATS CLEAR 00 o SEE CHAIR RAIL DETAIL x POLYURETHANE ST-21 ap \\ I N \ PLASTIC LAMINATE 4 1/2' PL-21 I WALL \ N - PL-21 B-21 PL-21 8-21 PL-21 8-21 TILE COVE BASE 8-21 C H A I R RAIL D E T A I L SCALE: 3"=1'-0" TYP . SALES AREA ELEVATION HALL ELEVATION ( TYP . ) TYP . SALES WALL DETAIL CHAIR RAIL IS 5/4 x 5 1/2 MAPLE SALES ELEVATIOJN , " WITH A 3/4 CHAMFER. SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 3/4„=1 -0 h X G.C. TO PROVIDE AND INSTALL CLICK & CLEAN DISP. ® m (SEE NATIONAL ACCOUNTS LIST FOR ORDERING Ln INFORMATION) NOTES: ® � ALL SHELVING AND HARDWARE SUPPLIED LLI a- AND INSTALLED BY GENERAL CONTRACTOR cs CL 2" x STAINLESS STEEL ANGLE CORNER GUARD G.C. TO INSTALL 1/2" PLYWOOD GENERAL CONTRACTOR SHALL PROVIDE Q 6'-0" LONG, TYPICAL INSTEAD OF GYPSUM BOARD AT ADEQUATE BLOCKING FOR ALL SHELVING PROVIDE 5/8" PLYWOOD SUBSTRATE FROM w p= LL OUTSIDE CORNERS POT SINK IN OFFICE 4-6 A.F.F. TO 6 ABOVE CEILING. ON p Z_ .---- THIS ELEVATION WHITE MELAMINE ROOM FINISH SCHEDULE Z I r---------r--------, P-30 FRP-22 SHELVES W/ BRACKETS FRP-22 FRP-22 FLOOR BASE WALL CEILING ROOM NAME NOTES p i I / ON STANDARDS TYP. CODE CODE CODE CODE DRAIN L---------L--------J / FRP-22 x x VESTIBULE T-21 B-21 GLASS * P-30 * SEE HALL ELEVATION WHERE NO GLASS STORAGE r�; SHELF I I I co PLASTIC LAMINATE OVER co �� I I I x I I SALES AREA T-21 B-21/8-23 * AC-25 * SEE INTERIOR ELEVATIONS SHELF = = Ii I I i I I o / PLYWOOD DESKTOP, - DRIVE THRU T-22 B-22 FRP-23 P-30 © ' II II r---------r--------I - // o x BRIGHT WHITE x L �:°' I I I / IEL o o SERVING AREA T-22 B-22 FRP-23 AC-22 PINE EDGE PAINTED TOILETS) T-21 B-21 FRP-23 P-30 ALT. WALL FINISH - CERAMIC TILE CT 4 X4 WHITE ,e u I I I ST-21 0� 'I _I * " " j________ ________` \\ ST-23 N P-30 UTILITY T-22 B-22 FRP-22 P-30 ANGLED PLASTIC p OFFICE T-22 B-22 FRP-22 P-30 v J i -i co LAM. KICKER, f ----- 1 ---- I \ r--- -t- -r �I \ I " I STORAGE T-22 B-22 FRP-22 AC-22 SINK D ; s '�'! I I I e\ N 2-6 BRIGHT WHITE L1J 10 a \ PREP AREA T-22 B-22 FRP-22 AC-22 MOP SINK HALL T-21 B-21 * AC-25 * SEE INTERIOR ELEVATIONS B-22 B-22 8-22 8-22 B-22 •• I— ui Z LEI OFFICE ELEVATION TYP . UTILITY ELEVATION TYP . WALL FINISH MATERIAL SCHEDULE < � - �. L1J PREP AREA STORAGE ELEVATION ( TYP . )- �c > ( CODE MATERIAL MANUFACTURER PRODUCT NO. DESCRIPTION " „ „ , » " , „ B-21 TILE COVE BASE KEOPE SERIES: JAPURA 6"X12" UNPOLISHED DARK p Z W SCALE: 1/4 = 1 -0 SCALE: 1/4 = 1 -0 SCALE: 1/4 = 1 -0 B_22 TILE COVE BASE METROPOLITAN 507 507 USE WITH T-22 TILES PURITAN GRAY m B-23 TILE STRAIGHT BASE KEOPE SERIES: JAPURA 6 x 12 UNPOLISHED DARK p USE 0 KICKPLATE N FRP-22 FIBERGLASS MARLITE P-100 WHITE PREP AREA, OFFICE & UTILITY A FRP-23 FRP-23 r ST-21 REINFORCED * V 1 FULL HEIGHT ST-23 FULL HEIGHT TYP. ALL WALLS TYP. ALL WALLS FRP-23 * POLYESTER PANELS MARLITE " "P-118 ALMOND SERVICE AREA, RESTROOMS 0 NOTE: IF FRIALATORS OVENS, USE CLASS A MATERIAL. HAND P-34 DRYER SOAP O P-29 PAINT SHERWIN WILLIAMS SW 6113 INTERACTIVE CR AM A WALLS HANDICAPPED � TE ACTIVE E LLLLJ GRAB BAR ;> LAVATORY GRABHANDICAPPED F DISPENSER P-30 PAINT SHERWIN WIWAMS SW 7006 EXTRA WHITE 0 G.C. TO PROVIDE MIRROR P-34 PAINT SHERWIN WILLIAMS SW 6363 GINGERY (METAL DOOR JAMBS & HARDWARE) LLJ RECESSED MOUNT C PROTECTIVE PIPE OA L2" M x \ /- SANITARY NAPKINCOVERS FOR ALL LAVATORY PL-21 PLASTIC LAMINATE FORMICA #85913-58 "RASPBERRY VINAIGRETTE" MATTE FINISH (WAINSCOT) DISPOSAL (WOMENS o `J EXPOSED PIPING 0 RESTROOM ONLY) ° - HAND SINK. _ TOILET EQUIPMENT SCHEDULE ST-21 FINISH SHERWIN WILLIAMS V84F82 OVER ST-23 -4 TOILET PAPER \�` " B DISPENSER t ,� x� ITEM DESCRIPTION MANUFACTURER & MOUNTING HEIGHT REMARKS ST-23 STAIN SHERWIN WILLIAMS SW 3112-K AUTUMN MAPLE SHEET I '� I �' 1'-7" I TOILET 1'-3" "M i� A GRAB BARS BOBRICK B-5806 36x42 36" MAX. A.F.F. NOTE C PEENED GRIP & POLISHED ENDS �,� iv B TOILET PAPER DISPENSER BOBRICK B4388 24" A.F.F. NOTE C SURFACE MOUNTED WC-23 WALL COVERING SURFACE MATERIALS L1BW21 FRENCH VANILLA AM C COAT HOOK ACCESSIBLE BOBRICK B-2116 48" A.F.F., NOTE A DOOR MOUNTED WC-24 WALL COVERING RIGHTER GROUP DD300 COFFEE CUP ICON WALLPAPER it 3'-0" TOILET D SOAP DISPENSER DERMA FOAM E NOTE A, C SEE NATL ACCOUNTS DECORATIVE WALL ON SALES AREA MAX. B-21 B-21 B-21 B-21 KAY CHEMICAL COMPANY WC-25 WALL COVERING RIGHTER GROUP 025429A DECORATIVE SWIRL BORDER - E HAND DRYER WORLD DRYER RA5E NOTE A, C SEE SPECIFICATIONS MATCHES DD300 & DD100 SALES AREA BELOW CEILING F MIRROR BOBRICK B-165-2436 40" A.F.F. TO BOTTOM FILE#:300331 , D05076 TOILET ELEVATIONS ( TYP . )- G CLICK & CLEAN KAY CHEMICAL COMPANY NOTE C _ WC-26 WALL COVERING RIGHTER GROUP DD100 WALL PANELS FOR SALES AREA NOTE A, C SEE NAIL ACCOUNTS I I I I I I TO MATCH DD300 DATE:10/3/05 SCALE: 1/4" = 1'-O" NOTE A: OPERATING CONTROLS OF ALL HAND DRYERS, SOAP DISPENSERS AND MULTI PURPOSE UNITS To BE 42" A.F.F. * SEE EXTERIOR FINISH MATERIAL SCHEDULE ON SHEET A8 FOR MP-25 PROD. MGR. J.R. NOTE B: G.C. TO FIELD VERIFY ALL SIZES. NOTE C: PROVIDE BLOCKING FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES. C.M. D. FLANNERY e O u REMOVE EXISTING WINDOWS; INSTALL NEW o� I ANDERSEN TYPE (SEE FLOOR PLAN FOR EXACT LOCATIONS INSTALL NEW ASPHALT I ROOF SHINGLES I @0 FLASHING; BOTH ENDS � PAINT ALL TRIM QFIST DORMER CHEEK W/ NEW � P24 PAINT CLAPBOARDS P23 PAINT ALL CLAPBOARDS FP-23-1 NEW 1 x 5, 6 CORNERS, (WHITE VINYL WRAPPED) REPLACE CORNER BOARD $ WITH STANDARD 1 x 5, STRIP ENTIRE SLOPED ROOF I 1 x 6 WHITE VINYL WRAPPED AND INSTALL NEW CHARCOAL GRAY s _ ASPHALT ROOF SHINGLES TRIM I � I I REMOVE ALUMINUM SIDING I & REPLACE W/NEW CLAPBOARDS 3 ! low f PAINT ALL TRIM 1 x 12 FACIA P24 - x 8 FRIEZE; � r B B ® WHITE VINYL WRAPPED) _ PAINT ALL CLAPBOARDS 0 - — TYPICAL P23 c� REMOVE ALUMINUM SIDING o r Yook au M I 00 3 LO (00 N WITH WHITE VINYLBOARDREWORK - X WRAPPED TRIM 0 in < ® 0 ® C L CLxw uj m ®< LL- REMOVE EXISTING STOREFRONT EXISTING DOOR & TRIM NEW ANNODIZED ALUMINUM STOREFRONT 9 (WHITE VINYL WRAPPED) AND GLASS TO MATCH EXISTING FRONT ELEVATION LEFT ELEVATION- SCALE: 1/4" = 1 f-0" SCALE: 1/4" = 1 f-0" NEW WHITE WOODEN HAND CARVED SIGN. CARVED LETTER SIZE NOT EXCEED EXIST. EXTERNALLY LUMINATED SIGN FACE W/ GOOSE NECK LIG-ITING FIXTURES LO REMOVE EXISTING WINDOWS; INSTALL NEW H O ANDERSEN TYPE TO MATCH EXISTING TYPE 8-`l�-1/2 F NEW CHARCOAL GRAY ASPHALT ROOF SHINGLES ® X V) X COLOR ORANGE Z >- 0 m PAINT ALL TRIM w ® V)FV? ul/ � Z w P24 D R Lf\j LA) a, Q- V) 4/ "` PAINT CLAPBOARDS V) �' F- P23 p i L NEW 5" WHITE ALUMINUM IL I GUTTER I ----- -� z PAINT TOP OF COLOR RASPBERRY VESTIBULE Q W I ® O C�_, (( nn� a 0 V I I O O Z W I I I NEW WOODEN POSTS — -i — PAINTED WHITE. m < HIGHT OF POLES AND SIGN ® L� COMBINATION NOT TO EXCEED EXIST. � � LL) d �p EXISTING DOOR & TRIM REMOVE A.C.; INFILL Q (WHITE VINYL WRAPPED) WALL FRAMING TO MATCH EXISTING. Li I� REAR ELEVATION RIGHT ELEVATION X f p f I f aD ill SCALE: 1/498 = 1 -0 SCALE: 1/4f8 = 1 -0f9 I go-in SHEET AM PYLON SIGN EXTERIOR FINISH MATERIAL SCHEDULE SCALE: 1/2" = 1f-0» CODE COLOR MANUFACTURER PRODUCT NO. P-23 SOCIABLE SHERWIN WILLIAMS #SW6359 FILE :300331, D05076 P-24 MINDFUL GRAY SHERWIN WILUAMS SW6293 f( P-25 FABULOUS GRAPE SHERWIN WILLIAMS #SW6293 DATE:10`3/05 P-26 PARIS WHITE SHERWIN WILLIAMS SW2088 PROJ. MGR. J.R. C.M. D. FLANNERY I_ I I I I ® 0 o o O a 20C 3 m O N <40t It i ! 425 Fn 425 � 493 _ o0 0 O ® N 00 481 L 2 m o I I Li ZA 42oB o N m o ; CEILING HEIGHTS � � C o �-� L 18 BSKTS 24 BASKETS Li I 1 / w HEIGHTS to Q I Do OF I / ® SALES AREA04 ROOM 8-10 uj � N BAKERY D NUTS 8 BSKTS 1 -J I / M = N VESTIBULE 7'-4" eo9 I BAGELS - SERVING AREA 8'-10" XLILL �j 96 o I ® omoo I 40 6 70.3 70.2 80.2 1 < 000 20F N N I PREP AREA 8'-10" 0 � I 95.1 STORAGE 8-10 z .. I HALL 8'-10" � wU) z ;;� f TOILETS 8'-0" Lu m O 12" 1 UTILITY 8'-0" = LL- I ---- _ 1 o1 C 101 D 103 3.1 102 101 C 101 OFFICE s'-o" BACK BAR SOFFITS 6'-10" -'� DISPLAY CASE SOFFIT 6'-10" ® ® ® i 120F i 110 UNDER ® 1 3.-0" 1. PO TERMINAL INFORMATION:110V C DUPLEXOUTLETS 1 o1 P t� c 250.1 ss) I 2. RECEIPT PRINTER INFORMATION: - 110V AC DUPLEX OUTLETS 01Q 101PP _ 1 - SHARED WITH TERMINAL OUTLETS 675 - WIRED DIRECTLY TO TERMINALS 3. REMOTE PRINTER INFORMATION: SELF- - 110V C DUPLEX OUTLETS _ SERVE - WIRED TO TERMINALS VIA RJ-45 COOLER J-BOX IN FRONT CABLE CHASE 4. VDU INFORMATION: { - 110V AC DUPLEX OUTLETS SELF- - MOUNTING: WALL, CEILING, OR 661 SERVE PEDESTAL W. I I - --- COOLER 5. OFFICE AREA INFORMATION: t-�--� - 110V AC QUADPLEX OUTLETS - 1 MODEM LINE REQUIRED FOR SUPPORT - 2ND MODEM LINE OPTIONAL FOR CREDIT CARD PROCESSING 6. NETWORK HUB INFORMATION: _ 110V AC DUPLEX OUTLETS - LOCATED IN FRONT COUNTER L CABLE CHASE L - CONNECTS TO TERMINALS, VDU'S, I BACK OFFICE COMPUTER SYSTEM - ORDER INFORMATION ROUTED TO HUB, THEN TO VDU'S & OFFICE (f) X gI Z >- Q ®_ m U) POS NOTE: a' a- Ln GENERAL CONTRACTOR TO PROVIDE FOR P.O.S. SYSTEM AS SHOWN ON ELECTRICAL IE J EQUIPMENT PLAN DRAWINGS 0R, AT MINIMUM THE FOLLOWING CONDUITS: U Q A) 2 1/2" I.D. FROM 4x4x3 JUNCTION BOX LOCATED BEHIND OFFICE DESK UP THE WALL TO w f=- ABOVE CEILING. ® Z SCALE: 1 4" = V-0" B) 2 1/2" I.D. CONDUIT WITH 2'-0" SWEEPS AT ENDS FROM A HUB LOCATED IN THE s FRONT LINE CHASE UNDER SLAB TO THE BACK WALL TERMINATE ABOVE CEILING. C) 2"x4" ELECTRICAL BOX 6'-0" A.F.F. WITH 1" CONDUIT IN WALL TO ABOVE CEILING. Z 1(51 CENTER 32"02%3/4" PLYWOOD WALL BLOCKING IN WALL FOR VDU UNIT. THE MAXIMUM CONNECTION LENGTH BETWEEN A VDU AND ITS DEDICATED CPU IN THE FRONT LINE CHASE IS 75'-0". THE CONNECTION THEN GOES TO THE OFFICE. G.C. TO PROVIDE ONE ISDN TELEPHONE JACK IN THE OFFICE. NOTIFY DUNKIN' DONUTS IF ISDN SERVICE IS NOT REGIONALLY AVAILABLE. LLJ PROVIDE DUPLEX RECEPTACLE IN CENTER 'VC' MENU BOARD SOFFIT FOR VALUE COMBO BOARD ON CASH STATIONS 27 1/2" 27 1/2" 4'-9" 27 1/2" 27 1/2" ST-21 12" 12" 12" 12" LLJ ST-23 Ld WC-23 Z W FRP-23 MB MB A25® ,,� e ; MB MB WALL FINISH MATERIAL SCHEDULE < —j v - - " LAP, L CODE MATERIAL MANUFACTURER PRODUCT NO. DESCRIPTION FRP-23 P-23 ESPRESSO \ B-21 TILE COVE BASE KEOPE SERIES: JAPURA 6"Xt2" UNPOLISHED DARK m < o I I r--, B-22 TILE COVE BASE METROPOLITAN 507 1507 USE WITH T-22 TILES PURITAN GRAY ® � „ „ B-23 TILE STRAIGHT BASE KEOPE SERIES: JAPURA 6" x 12" UNPOLISHED DARK ,_ Z' i0 a SINK FILLER I I MAIN POS GROUPI j j 3�� USE ® KICKPLATE I -1-----i OMIT Whr-COVERi1�fG__� I I o Lj C o JJ6 ---� BEHIND CASE TO LINE FRP-22 FIBERGLASS MARLITE P-100 WHITE PREP AREA, OFFICE & UTILITY I 9BI I� A19 A21 A23 ----- I �� I REINFORCED FRP-23 POLYESTER PANELS1 MARLITE P-118 ALMOND SERVICE AREA, RESTROOMS n * NOTE: IF FRIALATORS OVENS, USE CLASS "A" MATERIAL L� > SANDWIC B-22 LINE OF CASEWORK B V CTR. P-34 STA 0NH P-29 PAINT SHERWIN WILLIAMS SW 1087 WINDRIFT BEIGE ALT. WALLS OMIT TILE BASE BEHIND DISPLAY CASE STA11ON P-30 PAINT SHERWIN WILLIAMS SW 7006 EXTRA WHITE P-34 PAINT SHERWIN WILLIAMS SW 6363 GINGERY (FETAL DOOR JAMBS do HARDWARE) LLJ L -I WC-23 PL-21 PLASTIC LAMINATE FORMICA #85913-58 "ROYAL PLUM" MATTE FINISH (WAINSCOT) WRAP AROUND CORNER 6" PL-28 PLASTIC LAMINATE FORMICA #1150-43 "VOSGES PEAR" MATTE FINISH HALF WALL I INTO DISPLAY CASE AREA SHEET PAINT REMAINING P-30 ST-21 FINISH SHERWIN WILLIAMS V84F82 OVER ST-23 0 AV ST-23 STAIN SHERWIN WILLIAMS SW 3112-K AUTUMN MAPLE WC-23 WALL COVERING SURFACE MATERIALS L1BW21 FRENCH VANILLA WC-24 WALL COVERING RIGHTER GROUP DD300 COFFEE CUP ICON WALLPAPER 1 DECORATIVE WALL ®N SALES AREA BACK BAR E L E U A T I 0 N WC-25 WALL COVERING RIGHTER GROUP 025429A DECORATIVE SWIRL BORDER - FILE#:300331, D05076 K SCALE: 1/4" - 1'-0" MATCHES DD300 & DD100 SALES AREA BELOW CEILING DATE:10/3/05 WC-26 WALL COVERING RIGHTER GROUP DD100 WALL PANELS FOR SALES AREA P R O,J, MGR. J.R. TO MATCH DD300 � C.M. D. FLANNERY NOTES: NOTE: EX - EXISTING 1. EQUIPMENT SUPPLIER TO PLACE ALL NEW EQUIPMENT. N/A - NOT APPLICABLE REFER TO AWED DOMECQ QSR MULTIBRAND EQUIPMENT SPECIFICATIONS ON 2. GENERAL CONTRACTOR TO PLACE ALL EXISTING EQUIPMENT. AWED DOMECQ QSR WEBSITE, www.adrus.com/extranet, FOR COMPLETE 0 3. GENERAL CONTRACTOR TO MAKE ALL MECHANICAL, PLUMBING, * - PROVIDE SHELVING FOR REFRIGERATOR AND FREEZER, PER EQUIPMENT AND UTILITY INFORMATION. ADQSR WEBSITE ALWAYS TAKES AND ELECTRICAL CONNECTIONS FOR ALL EQUIPMENT. HEALTH DEPARTMENT REQUIREMENTS. PRECEDENCE OVER DRAWINGS IN INSTANCE C CONFLICT. L 0 oil I o x!! �I N Y m WW N CD C 3 h LL L OL (n �y c i v) O P M 9 m M Li w w Ld n W z z c W W L-j LL" LL �`' (.0 CO p ¢ J J N \ O z W L� I z Z z z Z 0 0 0 0 0 (n w 'g 3 66� W r F i¢- F¢- F¢- LL- W W n W_ U ¢ EnD En U)U)LA U N O LLI �_ 00 W I 6 z (!D C!D i/3 (n VD C!I I/) W 4 z S ¢ ¢_ to J n � r ¢ S !i ci O O O O O � W W J U z_ LJ w w m M Z ¢ U U 1i O O O W O V) ti LL W J z Li Li W m Oh U h h LA- m a, a a ¢ ¢ LL- W W LL.. Z ¢ `� O W V) z W O O c0 En N '< LL LL O V) U LX d' s tD Cy W W W W CO C3 = 04 U z r ¢ LL- La" r N \ O lrL , z O U U to � n U W w Ld w s ¢ ¢ J U p 0 n00 >- } > o w a. CL m Ls) W m M � M m m ¢ o a J J LL -� \ O LL >< ® w m c (fl I W w w w w U U ¢ U 3 0 0 N J "�� Lo n tl ¢ O O O w L� CL 0- a. a. a. 0- (n (n c0 O w W ¢ ¢ U W ¢ T P w w w ¢ P O p p = w w uj (o N M m T I J J W U .. 0 L� W n n U O ¢ ¢ ¢ ¢ ¢ W w u) J J <Z ¢ ¢ 01 W n Z W r7 to to 4 Q u- O V) V) p" Z Z ® 00 V) >- r r > CL LL a w F- F- U o ¢ U N 0 h h U o O J L_ n U U �, o o a = to <C 1 00 f -j Q a a a. , a= cw) cWi � M � U � o w w � U w � w Y �- Z) Z 0 w w g 0 u- J o o z m w a m ¢ w w w a�3 � c4 i «� U a. a. a_ a b- L,O n n U W w n n 0 � n n U J J w W w o O o m (n u) U U U W Z ° N ¢ O O O o O 6 Oy W Q_ m Z Z t0 0 z ¢ U U U o= V) W = U F w W U t9 Lnt.1 ¢ ¢ �' L L 1 X LL 1 t0 li LL ¢ ¢ W ¢ U LL- LL n � W W U U O J J n n n n U W W J J 2 U J W ¢ w a En M < C) � L w� �' LY r� r� w �wq M O O cn W W !mV O w F- d w w w by o t- W z 5 7 7 w w W J I L 1� U W L� W W W V) y) \ \ (L' LJ.I iy P U Z x U U Ld h F- h h h WCL ® ® O p P w U U a a m (!) W J O W O W La Ln w W (L ¢ F- LO Q ¢ ¢ ¢ ¢ ¢ to m to of O 1 w L d w O O m o h J ¢ () m uWi (Wn e cn m uD m O m C7 d/l LO 3 3 U U m n n O v n n U U in U m Ll' m n n U F- J w W U LL Z O O J O P W W La Z - (L W W W LLJ W w p a W -L J J LL_ O aS3 3 ai o- a_ N N c1' h h a. 0 m w L� w F- O m m a w U �` 0 ¢ 0 o a- a_ 0- O o of X u) V) i I u) h h V) ►+) 0 O Ld LLe1 N LO Ln u) Ln u) �Zry 3 LL- U p Ln t m u) u) fn N N O J 0 0 P N C,I N J J Z J P P P P V) W P P N Z J ® ¢ I ! I U LJ Ci C7 v L` \ I I a ®- = (L O (1 1 1 1 1 w Z U J n I I \ I I ¢ m I t (0 W W W W W t9 6 I I I M 0 tL (L a C9 : to W ¢ W � O a. O C� C� c� m m I h � A l t u- J J Ln W w O w 00 !1) LO W ¢ J m LP) LO LC) LL- co ® m Z � U N m LO N LL- LL- u- P P to (n p CL 1 9 w w w <C ¢ ¢ m m N N ¢ ¢ V) m U (nW ¢ w w ¢ ¢ ¢ ¢ ¢ M W Q U) O m La Q Q ¢ ¢ ¢ Lj W I I J J J J .._L tat w 2 M z Z 1 w M 7 z w En M M M M M w h U w L= 0 w w a. w J J J J J w w W W W ¢ ¢ w (j w W U U ¢ = U W w w w w W O O O w a w O Ld w ( W W Ww w w w = '0z ¢ ¢ ¢ ¢ ¢ u) V) z z z U U J V) a.. Z Z w w 010 LsJ h z z z z z N LL Z J WO MN LL N Z Z P 0 W M z z z tL U L-I �I a a o < P P - PPP - P - P P rPP P P PP (0 c) oa) a P P P P P N) P P M M P-- Iq CJ CV Cd Cd CV N CV hJ N cq N N C91 OP M Cn LI) Q) In M (� CO yr (0 P r Ln LO r 1 i 00 N J 04 I (PV P NT P P P P P NP N p 0N ONNNNNN NN N y pO o O O o N O O 0 NP PN N N LO 00 N N N CD O 00 00 N N N N N w N N N ) ^N 0 N N Lo 0 P P - N N O % P N N o P c N N P P - N N P Np C1 s .1-- s s e s s d d .0-1�1 d' d11� d d-IN, d d d d-1�1 d N V) to "I M M M M M to n M M) to � \ L_LJ ��--yy�^y LLP�,LL a s W n >- N N s ON s s 204 s s s s It : s s s s N Ld 0 m d- tb N N N N d d N N N N d d m N N N 00 0 Z� CD (0 0d' d' m le d- P d' 0) .-00 \ LA_ P Ld ¢ J O ►7 > ® Z J -L O LLl --- ® ~ LOO u- x x N N x d !=- V) N CO (7 n x J _ j a- N N J O O W N N d n U ¢ (0 s Da I \ O ® x Lh * Z Z Z la! F- LS - Lr) C7 O L0 0 z < d I N n N n J J J 00 io (0 cO Ln ® 0) C7 0 U 0 CO 0 0 CO z U n � •- ® O � d• O P F- F- F- I p s O O La) d n co m t0 m F7 N J n d J P 1 n n 00 t` ¢ d 1 N N x N Z Z Z J J n Z Z Z Z ? Z Z Z Z Z Z Z Z Z I tX7 0 0 O N O O Z Z Z Z M M FrJ P') O O d a Z Z Z Z M M M Z Z `� Z Z p N h O D D n Z Z Z Z O 00 O d O 90 tD d co Z Y = n \ L7 N 1 O Z I I Z 0 O O U P 0 0 G O O N x N -L N L) N O O O O P (D d N (O d N) N -d ¢ s N O ¢ ¢ ¢ +�$ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ P 'S O O J J J X X X X J J < J x x X J J J J O \ n h n I I (n (� N N N N J r J J `� m d d d d d d d d J (n (!D ¢ e- s �j Cn O = = j) Ln le J e0 O O I N N ¢ x �' �° ¢ ¢ \ (0 d J J J J J J J J J J J J J J J �- a U c) 0 0 0 O O O Q LL_ m W La LL LL_ LL_ d- tL a a_ a a o n a a a LL a s I L L L : e : Cj 3 3 3 3 3 3 3 n _ ►� I x O P i� er O I w d w o P o 0 tO tfJ O a 0 0 0 a a a a O O O U a a a a a a d a O O n O p w m X X X �- a a s co N N N N N N N N O- Z <L O O O I P J L� N O O L+) M N O Ln m ao a O N tD ^ O I ( 1 w (if O (D O t0 O O L°` r N W O o o +n tO o 0 0 I s O I tD (D I co m rn I O O O P O P h Cn (0 w d O ►`) P W W W W W W W W W W W W W W W LSO ¢ I 1 I I I mh U U 0 m 0000 04 M dN d0 n W W W W 17 M 17 M M n n O W W W W e1 N °w p W W M W W N -, i^L Q I n n 0 0 (JD W W W W I !n n n p D O D n n W � W el L i � y�y- CO U O n 0 ci a FO- N O N (on (on W � h i p N o M I pI cV w 0 0 I I 0 0 0 � M a W CL [L a a a a a a a s a_ Q a a a P > d tD tD m N N ¢ ¢ U N N N N rO h7 d• a. a. a. a 60 (0 M ►+) M n to d 0 a. a. a 0 r- 00 P EL a v EL a V Q r- m 0) n n n N N d L� �) P a a a a U ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ a P P a Y �* N I- = a. M 09 n 0 0 0 U U ¢ U Cd (0) (n a O 01 a. n m c0 U � > d a. N d d Ln c0 (0 LO m n n n h I � p I_L_I Z 1z ft: U U O U U U U U U U U U U w w z z Z 0 (A C 3 F 1= Z Z p F 1= p F F 1= F 1= F O O O i= 1-- h ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ V) (n ¢ J J w ¢ ¢ z z z h O O V) w_ ® ® n I� W I i w w I I I I I I I p I I p U C? ® n 0 0 0 = W Y O 3 m w = w p w w w l,_ n V O O O I— 0 0 CL a_ 0 0 0 0 O O O O 0 0 O O O O O O O O o 0 0 0 0 O O w 0 0 0 0 0 0 I I 1 I I 1 0 0 0 0 0 0 0 0 0 0 0 I I I w 0 0 0 0 0 0 0 0 G 0 T O O a= 1 w ¢ W a W W w O O ¢ ¢ ¢ h I N L;. F- ¢ ¢ m o 0 I rz C� m m L 0 CO C� n J o z tY m a_ O O O O eY 0 0 0 O O O O O O O O ¢ U = = LPL a ¢ L� LPL LPL L�� L�� ¢ O O O ¢ ¢ tY O o: ¢ ¢ ¢ ¢ ¢ 0 0 g g Z U U h h h h F- F- h (n F- Z 1= F- 1- F- L- F- z n n h ¢ > m O O ® ® O ® Oh ® W F- F h h h h h h h h h h h h h ¢ h h h h h h Z z n n z Z Z z J h h h h h h h h z Z z Li h h h h h h h h h h Z h h m z Li r! Z M Z L'- LL- V) uy V) (n V3 VI V1 z O IY (h/) IY J = <[ O 0 w of 0 0 0 0 w 0 W w 0 (n u3 V) _ M 0 0 W 0 0 Z Z �' z z z z 5-' y- 'rr V) N V) m V) V) V7 w z z z J (n u1 V) (n 0 (n u! to V) V) Z Vf (n � Z J J ¢ _L -L Z x � VI 6� 1-`' � J J X � Z -+ X X X X X = � z Z V) 3 3 = tY � � V) V~i m V) V) V) V) V) � m V3 ul I �1_I O o 0 0 0 0 0 0 0 0 o O O o O C) O O O o 0 0 0 O D U ¢ O O o 0 ¢ ¢ d O > > > > > > > > > O w O o O o O > > > > o O O O ¢ O w O x w w w w 0 0 0 0 = w w w w w w w w O w w 0 O U w w w ¢ w O ¢ ¢ ¢ ¢ ¢ O w O o o w w p w ¢ O ¢ ¢ ¢ ¢ > > O O o 0 o O ¢ O O O W U ea O D U U c� U U U U O to U U 0 U U U 0 0 Ulm m ¢ ¢ h m m m m h h h U U U U U U U U m m m n U U U U v U 01010 U m U U U m n = a. 0 ( n n M M V) i� i� ita U U U c> � J � � � � � � � � U � � z = 3= n a m m m w z � � m m m m m � z � m U z z w N U z 3 3 3 3 0 0 0 U U U U U J a a a � lwLJ _ ® cyrn M "itW ! Q I y J rn g U W U N M z - x x W w -, m c s s Ld Q t1 J -1 J ¢ O O � Z Z Z Z j Z o w Z Z Lp s N N m a w J -, J J n (/) Z Z Z_ -� 0 LO .d N p V) uF Z W _ W w w W W W W W f ® x Z Y z l I V -� J U LL- 0 \ O w N n [� n p �f� p m p w w w w w w - U o U 0 O F- J O a P Q w >- >- >- >- >- >= z z z z z z c'i ¢ ¢ w m M w ¢ z Y Z ¢ I z z w I .. .� d Ln m ¢ ¢ ¢ ¢ ¢ La w I Y J U o w m a= O O W = V) �}" Ln 2 J J J .J J I L LA Ln M h m LL- m LL- c> O o 0 o w J Lh P P e e ... as v .. u N u d' W h h h h h h -) J m U Q �' cC �" �' m LPL I I 1= F- W L✓) Vi 0 I V) \ a a Q a a E n z z z z z z I I I f h n w = x .. U I Icn W LL1 w W W w w O Z ?: W Q' Y 3 h F- F- F- J F- h W LL- .� ¢ ¢ ( V7 I Z a m o! n U) .. w m z z z z m m w tY z I I I I I I O z z v9 V7 m J z Y J h a _ V) N W n n n n n �n ww p LyL LyL W �yL > 0 O m Y Y ® O W Lil tY ¢ Q LPL = _ U U U U U V ¢ (¢j s s O Z LL- LL_ LL LL LL LL_ , J (n O O O O W W = O O > > > > Z Z H F- (L' ®- n H Z = W 1y W U J CO Z W U h �' �' �' �' �' U U U W W w O L'` O I I z CO m O I= � F F L J L L L O LL n W O Y N h C3 W U 0 0 0 0 0 4 Q m mCL m F- I I I ! i I _ J ¢ ¢ ¢ ¢ LL LL_ h h ¢ •• _ 0! O O = ¢ ¢ W 0 O h L� L�� L� LPL v U W J_ Ln� I n I � N ¢ X j O O O O O ¢ ¢ ¢ ¢ ¢ >- r > m n n ¢ Z h w ¢ H < CO h h L L 3 > > > > (� U) u7 u) (n VI va � I- n U ¢ N O W w W tL LL >- c7 ui cs tei u ¢ ¢ h ¢ n n F U h h h h tL LL_ W 4i n n n n V) ul LL O H FZ h F_ _ h h h J OG (� J J J -L -! J ¢ J I h z Z Z Z Z z Z Z h (!) z V) (/) V) (/) O O O a= _ ¢ ¢ S Z Z ¢ ¢ ¢ ¢ O J ¢ LL LL ¢ G3 Y U U < W J J J J J V) w w w CL a a L3 a J W Uo 0 0 0 0 0 0 ¢ d U W U U V) W ¢ Z ¢ 1- h h O Law h 0 0 3 3 F- Z Z Z Z Z z Z Z 00 ¢ m z WZ F- I - (p) c� t� J s h h U U C9 CO CO O U O p I I I I (/) (/) I Z CO U U V) < I= F 0 0 0 O \ Z O = O O O O a 9 Z V> m W ( ? ¢ Y ¢ ¢ a- LL a _ cr \ \ U w n n n n n < s < z J G f= F I= z z ¢ ¢ L_ j o o n n z z z z Z O a °� C!3 (n u) m m 0 c� h O J h I O U a Z Z a a I� n 0 n (] n (/) m O ¢ ¢ ¢ ¢ ¢ ¢ W z z Z Z J J m C7 O > ¢ ¢ ¢ ¢ (0 U V) V) n N LL- LL ¢ ¢ tY � w LL' � W � h Y Z � � ¢ O 0 0 0 O O z � � w n n Fr! O Cn L- � V) h h h h h h n n O Z O O O L L. Z ¢ V) F- F- I- h L u Y Y h F- U U U U ¢ CO O C9 O (� C9 (' (� z W z W V) F- (!) (n u2 (n m o_ U U W w w w CO 0 * LL_ (n (n N V) Z O C9 LY ¢ w F- = Q 4 Y Y a ¢ W W ¢ V) J Z ¢ ¢ 0 0 0 0 0 m w m > > W F- Z Z Z Z V) U Z Z Z Z Z Z z Z W �' = J O ✓ 0_ Y J Y U U U F- LL h h x z O ¢ n h h m m [1' w -' (/i uJ ui ui uJ ul W �' �' a' w W `� " I z z z F- z z ¢ ® w w w h z w w Y Y o h a w w S S S S S S S S Z = co c_ m 1 �`' U J �° ¢ w w w h ¢ o = z m 0 > > 0 0 0 W -° w a ct w w w w w w W = = s o= 5 S = = I o w w w w w w Lr a. n. z F= z J _ _ U Z Z Z Z Z c0 W U ® O O O ® w 1Y m 0 X ar z w w � LY w w � LL n .Y J J J J J J J J <( W W W .-. go LLJ OOo00 ¢ (9 .� (rsa- UUUUU (.) L'JW Zz c� UUO � wwmmmmUU � � NWLLzUUUU � o: mNv► w � �' hmm ® ® 000Ot¢_ -, ® ZUOWwwwwWWw � m � -, \ zM =' C� ¢ = w � MZ � s = JU1�- z z � nF- = = = = XF== 0 0 V< a: a CL a s w U) y ¢ ¢ ¢ m m n n 0 h O 3 LL La_ LL LL W U ¢ O ® _ _ _ _ _ _ _ _ ¢ J W W M LL M U D z z m O m z ¢ (/) m n n n n n gt ¢ m S S S S S S m (n Z L� w W 0'_ J = = w w w w = = W I- V) O S S S S Li V) C3 Z Z W V) V) F- O Z (n h h h h Z O O m W m °� Cto m Lx a! c� uL a. a- w w n O LL. t% u) (n g n z LL- z z H D! m o' °'� z g g = J O (n u) (n (n V) V) N V) a Vi O w J N W ¢ n w W ¢ ¢ urm r, Vim I W W W W W W w O W W LL- W Ww F- J J J J W A e a : : ¢ U W Li- h Lg Lr z Q F- m W W O \ ® C?Q ® h h F'- h h h h W W W W w W h h a Ln Z z n 0 = 0 F- F- Z p W ¢ W W W W >- m• Y ¢ O O ® O w tL LL LL_ LL U Z C) ¢ U U O J h M � >- >- >- >- >- n w w Li W w La l W L xJ h W z z Z z z Z W ® V} V) (/) V) C/D V) ¢ ¢ V) p m m ¢ ¢ ¢ ¢ LJ s s s s O ¢ O L O Q: L�L LyL 0 0 O D_ m ¢ Z C9 CL h F- m m m m m Z a Z g m = L�L Y Y Y Y Y W Y J al _I et zi _i Z (/) W W n LL U h h F- h W W W J J J J ¢ ¢ a h (n N (n N h O ¢ O ¢ ¢ w W W W �' \ Z (ry d• d d d Lm m Lxb L70 d = �r U O 1 O ~ 0 O F- M- O (, m F- F- C9 m ¢ CC a= <m < 0 SHEET tL LL_ LL- tL tL n W z o tY _ Y -L G? W W W W W W = _ ® W w CO U h h h h z z Z O O O O = _ C0.O - (_/) N h � W W W W <L W O LL_ LL_ ® (n V1 � Z LL LL_ _ � = Z O � W ¢ >- Z N N N N P P P P U P (� z � U � � h Lg � ¢ � a. ¢ ¢ o' a_ � ¢ ¢ z a. F¢- U W Z v O �e ¢ 0_ � d 0_ LY ¢ ¢ ¢ ¢ ¢ --, J -� > > > > n O O U O O ¢ z J J = O Y Y (/) V) V) to I a O w I W ¢ : ¢ F-' W a a (/) 3 ?r W w W O W W (n IX n h ® \ \ w w W W w h h h h W w W W w w w } O W W V) w w w w O U U X X X X X X X X X (/j �_ J O m J J = = Li) W W E W W W W W W W W V) M w w = w ¢ z z z z Z Z Y L� <L to LL LL- LL- W h h ¢ LL Lo J Y J J J J Y Y Y h h J w Z V) W U w n W W ¢ ¢ w w (y- � n L,� , Z W Y J N Z h O O ¢ J J J ® > LL_ LL_ LL_ lt_ LLL_ Z ®w Z m w Z mAV m m m m m m m m O 0 0 0 0 o U a W LL_ ts- tL LL la Le_ W U' ¢ LL w ¢ Z O O O O D U U LL- LL ¢ n W a N O LL LL- LL- LL_ W W nW W W W W Z U O U : : W W z F- �- s J O W >< O ¢ z ¢ n n n ¢ n n x h h .Tt a. m h h Z Z 3 U �U' O ¢ m m m h ¢ ¢ LL LL- u- LL- u- W w � (--L Lu L- J n a- ¢ a x x L s QC > oosa �, NN Nc roc � L ¢ Lnoo00000oan �LGoao0Goo ¢ ¢ ¢ - - - - OOnzCLo 0000 ¢ ¢ ¢ _ ¢ Nh � � �' � ° �' ¢ ¢ wz � � 000 �n � 000 �D � � �D � ¢ o -- JM 'i -j c� � c� cr ¢ c„ Lr, o ¢ o = onoa nz ¢ ¢ ¢ _ � L� 00000w o< ®d E to n N P "i ,-- CO P u- La- L� LL lL LL_ m w U U 0 0 0 U 0 (n n En E: U U min U U U Ulm m m = S = x (n w o O o Ulm CL U U U 0 010 01010 V ® z m m � � M N m m O 01010 z 0 V) w w F- t0 sF n N C® It r� N F- 17 P � U V 2 La. LL n (.0 w W w F- w w m t- P U M 5 ¢ ¢ LL LL ¢ a (n Z V) U F- F- F- (n F- F- U U U U U LL eo x> .t Z> N S ¢ <e ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ o :_ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ :Z Z P P Z Z P Z Z P Z P Z Z P P Z Z Z PZ P z Z N N N Z N Z Z Z z Z z z z z Z z z P Z Z Z Z Z Z Z Z P Z P P Z r N N r N N P P P N P Z P P P P Z Z Z N P Z N P Z Z Z z Z P N N Z % Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z z Z t. Z Z Z Z Z Z P P Z Z +- z z Z Z P 1(R—`jbz ¢ (L P P ¢ ¢ n u- P P P ¢ r ¢ m U n w O ¢ m '" ¢ m U n ¢ m U n LL.. O n m ¢ m U ¢¢ ¢ U n w a a O QP N N M d O O N N n d- 0 N N N O n O P O P P M 0 0 0 o 0 0 0 o P r) d Ln m m O L� d Ln FILE :300331 0�0 6 0 O O P P o d' LO (D o P o o N o 0 0 o P P P P tO m (D o c) P D �h O P N LA LA (D h o O P N 0 0 0 0 0 0 0 0 0 P N Pry O o 0 0 00 O P N O j`C3 O O O N L� � LO tf) (D (`` O O n O O Q O 0 0 0 0 0 0 0 P P P P N N N N N N N N d' d' (0 � 00 00 Ca 00 O O O O O O O O P P P P M M M ►� M Mn M LO Ln h O O O N N N N N N N N N N N CO W C) O P P P N N N N N N M M M M d' � Ln LO (D (O (D (0 (0 (O (D O P N L7 lO (0 (0 N � n h n QO O O O �yL`• h 9` i`• (C3 (X3 m C)D 0) 0 0 M O CIA O 0 P P P P P P P P P P P P P P P P P P P P P P PPPPPPN N N N N dNN N N N N N N N N N N N N N N d d' d' "t d d' d' d' d d' d d' d' U) LO LO 0 0 0 l0 0 0 0 0 0 0 0 In 0 0 0 LO LO LO LO Ln Ln LO LO (D O CO cD Lo (O (D (0 (o (D (D (O LD 00 La co DATE:10/3/05s.__ _ PROD. MGR. J.R. C.P . B. FLANNERY ` giI i LEGEND 10/03 I _ NOTE: LIGHTING IN TOILET(S) AND OFFICE IS TO BE SENSOR LIGHTING, VERIFY W/ OWNER. Al MET 2GR8-332A-120-ADV-EEX 2 X 4 RECESSED FLUOR. W/ACRYLIC LENS 0 Al W/ GE F32T8SPX30 (3), 4' T8 32w, FLUORESCENT LAMP Al-F MET 2GR8-332A-120-ADV-EEX e 2 X 4 RECESSED FLUOR. W/ACRYLIC LENS, W/ FLANGE KIT FCS24WIJ Al-F W/ GE F32178SPX30 (3), 4' T8 32w, FLUORESCENT LAMP Al-P MET 2EP3GX332S361-120-ADV-EEX 2 X 4 RECESSED FLUOR. W/PREMIUM PARACUBE inn 6 d Al-P W/ GE F32T8SPX30 (3), 4' T8 32w, FLUORESCENT LAMP Al-PF MET 2EP3GX332S361-120-ADV-EEX 2 X 4 RECESSED FLUOR. W/PREMIUM PARACUBE, W/ FLANGE KIT FCS24WU Al-PF W/ GE F32T8SPX30 (3), 4' T8 32w, FLUORESCENT LAMP Al-PO MET 2EP3GX332S361-120-ADV-EEX-OAO 2 X 4 RECESSED FLUOR. W/PREMIUM PARACUBE 7TE A5 A5 Al-PO W/ GE F32T8SPX30 (3). 4' T8 32w, FLUORESCENT LAMP _ I Al-PO F MET 2EP3GX332S361-120-ADV-EEX-OAO A11 � Al 2 X 4 RECESSED FLUOR. W/PREMIUM PARACUBE, W/ FLANGE KIT FCS24WU W/ GE F32T8SPX30 (3), 4' T8 32w, FLUORESCENT LAMP I _ 0 A3-PO MET EP3GX232S181-120-ADV-EEX-OAO O 1 X 4 RECESSED FLUOR. W/ACRYLIC LENS W/ GE F32TBSPX30 (2), 4' T8 32w, FLUORESCENT LAMP A5 Al. B HALO H880E-870C OB 32W ELECTRONIC FLUOR. DOWNUGHT, (LENS COVER OVER FOOD PREP) !All W/ GE F32TBX/SPX30/A/4P (1). 32w TRIPLE TUBE BIAX FLUOR. LAMP - � vi C5 TTF DD140BK ® h .�- e 12 FROSTED HANGING GLASS PENDANT m h �- 005 W/ PNS EFG23E28 (1), 23w FLUORESCENT W/ BALLAST LAMP M I m Al _ Q 00 :2 04 1 A -' TRACK HALO 2', 4' & 8' LENGTHS m to � 652P, L651P, L650P, L901P, L957P, L900P, L908P, L983N. ® _ 1 LLJ ro A17 co Al rL TRACK AND PENDANT ADAPTERS FOR FIXTURES C5 & Dl m m 001 Dl HALO L3240EP/MSP5234 p c~n Lo Al A17 Al A 24" SURFACE TRACK MOUNT MENU FIXTURE W/ SAFETY LENS z FC DUAL 4' LOW TEMP FLUORESCENT FIXTURE PROVIDED WITH "PACKAGE m = � 8 8 COOLER UNIT"/ALL WIRING BY ELECTRICAL CONTRACTOR [t 19 3 A3 H(AV) HUB AFF-64E-WL H(AW) W/ SOANDARD DOUBLE-ENDED BIOP°N CLEARLW PROFILE TWIN TUBE FLUR. W/TYPE LAMPOLY LENS Al _ C 49 i G HALO PM17 G EXTERIOR WALL PACK W/175w METAL HALIDE A31 IJA C14 TYPE "H" FIXTURE, SURFACE MOUNTED "LITTLE INCH" SOLID FRONT UNDER CABINET FLORESCENT TASK LIGHT FIXTURE; ROCKER SWITCH ALKCO CAT. NO. SF-116-RSW-FUSE, OR EQUAL A�t J� J SLC 852V - LAMP INCLUDED ® N Al RECESSED SOFFIT FIXTURE W/ 175 METAL HALIDE Al Al Al Al o O TYPE "K" FIXTURE: INCANDESCENT PORCELAIN FIXTURE O SPEAKERS RADIO SHACK "B" FULL RANGE SPEAKERS #40-1272 WITH WHITE ENAMELED GRILL #40-1225. 4b RUN WIRES TO OFFICE, VERIFY W/ OWNER. o CEILING MOUNTED TELEVISION - VERIFY LOCATION WITH OWNER AND D.D. A A A TV CONSTRUCTION MANAGER B38 K)4W W SUR CC2-V J J 2 J J (1 OR 2) LAMP ADJUSTABLE HEAD EMERGENCY LIGHT, WITH SEALED LIGHT, F1 ® t>oW WITH SEALED LEAD CALCIUM BATTERY, (WP) IF OUTDOOR WATERPROOF k@Ws WALL SCONCE SLP 8340-15/9008-12 Lo I A EXTERIOR GRAY WALL LIGHT W/ LENS ui p i Al5 A13 A31 A35 W/ GE 50PAR30/H/FL-25-130V (2) LAMP � 1-1 X PROVIDE 6' EXTRA WIRE X X SUR LPX70RWH LED EXIT W/ BATTERY M Xi I Z >- § AC MARS AIR CURTAIN - 800-421-1266 0 m DRIVE-THRU MODEL #E48C/CH-3, REAR DOOR MODEL #E48CHS-3, WITH DOOR MICROSWITCH & HEATER SWITCH, FURNISHED BY > z w MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR. ® V) W In VC 1 2 3 4 5 6 VALUE COMBO & MENU BOARDS CL ELECTRIC A LIGHTING HOOD/ FAN - FOR TOASTER OVER SANDWICH STATION IN SOFFIT V) F= SCALE: 1/4" = 1'-0" 1F-1 GREENHECK SP-115, 150 CFM, 1690 RPM, 1.0 AMP, 75 WATT p z HOOD/ FAN - FOR TOASTER OVER SANDWICH STATION IN CEILING USE CAPTIVE-AIR 24" x 18' HOOD WITH 24'H, 150 CFM, D.V. FAN T,F-1 TEF-1 TOILET EXHAUST FAN, NUT #8814, 100 CFM BATH FAN --,SPEAKER ' SEE DRAWING SHEET M1 FOR DETAILS ENU BOARD POST KEF-1/ PREP AREA EXHAUST FAN(S) - FOR OVEN HOODS �" 1" CONDUIT O KEF-2 SEE DRAWING SHEET M2 FOR DETAILS (LOW VOLTAGE) 5'-0" MIN Z & PULI_ STRING 48" MAX. /-SURFACE OF ® TYPICAL SUPPLY DIFFUSER FOR FUTURE = V VEHICLE CONFIRMATION FOOTING NCL ORDER < I LANE OF LIGHTING SCHEDULE NOTES: ® EXHAUST FAN GRILLE FOR TEF#1 C � EQUIPMENT MFGBAS. AND N d _ I ASPHALT OR a rr�� CONCRETE POS NOTE: 1, PROVIDE ALL FIXTURES COMPLETE WITH LAMPS. `J CODE 11 uI I GENERAL CONTRACTOR TO PROVIDE FOR P.O.S. SYSTEM AS SHOWN ON ELECTRICAL 2. ALL INCANDESCENT LAMPS SHALL BE RATED 130 VOLTS. DRAWINGS OR, AT MINIMUM THE FOLLOWING CONDUITS: 3. ALL BALLASTS SHALL BE HIGH POWER FACTOR FLUORESCENT BALLASTS FOR T8 . 04 GUIDELINES A) 2 1/2" I.D. FROM 4x4x3 JUNCTION BOX LOCATED BEHIND OFFICE DESK UP THE WALL TO 4. LAMPS TO BE OSRAM/SYLVANIA OR MAGNATEK FULL-OUTPUT ELECTRONIC, EXCEPT ® Lv D R I V E.--TH R U GUIDELINES ABOVE CEILING. OUTDOOR FIXTURES TO BE ZERO-DEGREE MAGNETIC BALLASTS. r n^ �- — � B B) 2 1/2" I.D. CONDUIT WITH 2'-0" SWEEPS AT ENDS FROM A HUB LOCATED IN THE 5. PROVIDE HOLD DOWN CLIPS FOR EACH CORNER OF FLUORESCENT GRID TROFFERS. �" F_ V I N.T.S. CURB FRONT LINE CHASE UNDER SLAB TO THE BACK WALL TERMINATE ABOVE CEILING. `_ 3/4" CONDUIT WITH 6. PROVIDE ALL REQUIRED MOUNTING OR HANGING HARDWARE. U ELECTRICIAN INSTALLED C) 2"x4" ELECTRICAL BOX 6'-0" A.F.F. WITH 1" CONDUIT IN WALL TO ABOVE CEILING. 7. COORDINATE AND VERIFY ALL FIXTURE INFORMATION, TYPES AND FINAL LOCATIONS - PULL STRING CENTER 32"x32"x3/4" PLYWOOD WALL BLOCKING IN WALL FOR VDU UNIT. WITH THE REFLECTED CEILING PLANS. -i Q 18" X 54" GROUND THE MAXIMUM CONNECTION LENGTH BETWEEN A VDU AND ITS DEDICATED CPU IN THE 8. LAMPS SHALL BE AS MANUFACTURED BY SYLVANIA, WESIINGHOUSE, GENERAL ELECTRIC, m z I '• ra 3• ------ 2 INDEPENDENT " 0 LOOP VEHICLE FRONT LINE CHASE IS 75-0 . THE CONNECTION THEN GOES TO THE OFFICE. G.C. TO OR APPROVED EQUAL � GROUND LOOPS DETECTOR PROVIDE ONE ISDN TELEPHONE JACK IN THE OFFICE. NOTIFY DUNKIN' DONUTS IF ISDN 9. FIXTURES MUST BE PURCHASED THROUGH A NATIONAL ACCOUNTS PROGRAM WITH SPEAKER TOWER & MENU FOR 11MER AND SERVICE IS NOT REGIONALLY AVAILABLE. VILLA LIGHTING SUPPLY INC. 1218 S. VANDEVENTER, ST. LOUIS, MO 63110. PLEASE -- -------<I CONFIRMATION BOARD " COMMUNICATIONS NATIONAL ACCOUNTS, AT 1-800-325-0963 OR FAX F3C,4 COMMUNICATION CALL MELANIE HURLEY, o A• 110 15 AMP DUIT 1-314-531-8720 FOR PRICING. �-� DEDICATED CIRCUIT � t.�l DRIVE-THRU NDUIT/ 20 AMP MENUBQARD ELECTRIC 0 PYLON AND EXTERIOR SIGNS Z NOTE: PROVIDE PVC 6 U LLB CONDUIT FOR WALK-IN ALL NEW 4, _6x CONSULT OWNER FOR LOCATION AND SIZE OF PYLON SIGN REQUIRED; CONNECT TO A35, N 0 TE S LJ._.I / n LOCATIONS; SAW-CUT SUPPLY ALL WIRE BOXES AND CONDUITS REQUIRED. CONNECT EXTERIOR SIGNS TO CIRCUIT L-;J AT EXISTING LOCATION MINIMUM OF A31. CONNECT MENU BOARD TO CIRCUIT A33. VERIFY LOCATION WITH OWNER. 1. PANEL BOARDS ARE PROVIDED FOR CHECKING TOTAL SERVICE REQUIREMENTS E.C. WHERE NECESSARY. ONE CAR SHALL USE BUILDING PANEL BOARDS GIN ETHENT ° REVISING CERTAIN MOSTECONOM ECONOMICAL MANNER.CIRCUIT'SEQUIPMENTD ARRANGING ®N MANNER. E.C.E.0 SHAH Li DETERMINE FINAL i LNG 00 SERVICE LOAD REQUIREMENT FROM LOADS GIVEN IN PANELBOARDS AND PROVIDE BEFORE NOTE: DRIVE-THRU 15' CURVE OF SERVICE ACCORDINGLY. MENU SHOULD BE LANE COMBO ELECTRICAL PLAN KEYNOTES 2. INSTALL ALL ELECTRICAL OUTLET BOXES HORIZONTAL AND FLUSH IN WALLS WHERE PLACED AT A 74��/ POSSIBLE. PROVIDE APPROPRIATE FLUSH (MOUNTING RECEPTACLE BOXES AND CONDUIT SHEET 45`ANGLi TO UILDIN LAS REQUIRED FOR MOUNTING OF OUTLETS ON CONCRETE WALLS. ONCOMING TRAFFIC i 1 EXTERIOR LIGHTS, PHOTOCELL ON, TIME CLOCK OFF. BOLLARD BOLLARD � �; � -CURB ® 3. EXTERIOR SIGN JUNCTION BOX TO BE MOUNTED ON INSIDE OF WALL EXTEND CIRCUIT (WHERE POSSIBLE) s• TO SIGN. ® POWER FOR EXTERIOR SIGNS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. 4. SEE "TECHNICAL REQUIREMENTS FOR THE COMTREX SYSTEMS CORPORATION DUNKIN' NOTE: SEE ADQSR WEBSITE, / DONUTS P.O.S. SYSTEM. FOR ALL INFORMATION RELATING TO CASH REGISTER WIRING. www.adrus.Cam/extronet, FOR SPEAKER DRIVE-THRU (FURNISHED DUNKIN DONUTS.) COMPLETE INSTALLATION CONTAINED MENUBOARD 5. PROVIDE CORD WITH. GROUND AND CAP FOR EACH COFFEE MAKER AND CARBONATOR. INFORMATION AND DETAILS WITHIN SIGN NOTE: "P.O.S.", ALL POWER OUTLETS FOR P.O.S. DEVICES ARE DEDICATED CIRCUITS WITH 6. SEE INTERIOR ELEVATIONS FOR DIMENSIONS AFFECTING THIS WORK. FOLE :300331, D05076 THIRD WIRE ISOLATED GROUND. AN IG IS AN INSULATED WIRE, SEPARATED FROM ALL 7. SEE SHEET K2 FOR EQUIPMENT CONNECTION REQUIREMENTS. DRIVE-TH R U MENU LAYOUT (PREF.) DRIVE-TH R U MENU LAYOUT (ALT.) POTHER ANEL GROUND WIRES, STANDARD RUNNING I1NG BACK I.G.KFTO THE THE RECEPTACLE IN OR COMP USE LEX POWER 9• E.C. SHALL PROVIDE DOORBELSTEM PER LS AND BU"eD DUNKIN' DONUTS SPECIFICATIONS.DONUTS SPECIFICATIONS. DATE:1 0/3/05 PROD. MGR. J.R. DUPLEX OR QUADPLEX OUTLETS: (I.E., HUBBELL IG-5262, IG-5362 OR EQUIVALENT). E.C. SHALL VERIFY LOCATION OF EQUIPMENT WITH DUNKIN' DONUTS FRANCHISE OWNER. C.M. D. FLANNER MAIN DISTRIBUTION PANELBOARD VOLTAGE: 120/208 PHASE: 1 LOCATION: SEE PLAN BUS AMPS: 400 WIRE: 3 MOUNTING: SURFACE MAIN OVERCURRENT DEVICE: REMARKS: (� AMPS:AIN 400 CIRCUIT BREAKER BREAKER LOAD BREAKER LOAD CKT DESCRIPTION CKT DESCRIPTION AMP POLE KVA HAS AMP POLE KVA PHASE I 1 PANEL "A" XXX 3 XX.X A 2 PANEL "B" XXX 3 XX-X A I 3 (SEE NOTE BELOW) B 4 B - 5 C 6 C 0 7 HVAC UNIT #1 - 6 TONS 40 3 3.36 A 8 HVAC UNIT #2 - 6 TONS 4® 3 _3.36 A 9 3.36 B 10 3.36 B Q 11 3.36 C 12 3.36 C j 13 MICROWAVE 20 2 1.73 A 14 HOLMAN TOASTER 20 2 1.6 A 0r 6 15 1.73 B 16 1.6 B r-_.----, ------1 17 MICROWAVE 20 2 1.73 C 18 ICE MACHINE 20 2 1,4 C I I I 19 1.73 A 20 1.4 A M18 21 SPARE 3 B 22 HVAC UNIT #3 - 6 TONS 40 3 3.36 B 23 C 24 3.36 C SEE P.O.S. 20 25 A1 26 1 .36 A NOTE "A" KV=.8 KV=.8 27 SPARE 20 1 B 1 28 SPARE 20 2 B M35 M35 29 SPARE 20 1 C 30 C - _ co 31 SPARE 20 2 A 32 SPARE 20 2 A ® M m 33 B 34 B 00 35 REACH-IN FREEZER 20 1 1.6 C 1 36 AIR CURTAIN (REAR DR) XX 2 XX.X CINS C4 �¢ o 37 SPARE A 38 XX.X A 39 SPARE 2 B 40 SPARE 2 B 0 41 C 42 C co o� ® 00 3 3 2 3 a :t o N <m m �7 � M D jV) co N_ m <o0A2 A2 A25 A21 (n U SEE P.O.S. " " w I I NOTE B PANELBOARD "A" m ®< 0- _. 822 B21 VOLTAGE: 120/208 PHASE: 1 LOCATION: SEE PLAN I BUS AMPS: XXX WIRE: 3 MOUNTING: SURFACE 20 20 MAIN OVERCURRENT DEVICE: REMARKS: Ag J J CIRCUIT #M-1 44. AMPS: 40 30 40 CKT DESCRIPTION BREAKER LOAD CKT DESCRIPTION BREAKER LOAD 842 B42 AMP POLE KVA HAS AMP POLE KVA HAS 7.OKV A14 36 A2 A4 7.Ell I 1 LIGHTING * P/S 20 1 .9 A 2 CASH REGISTER 20 1 .2 A .8KV A16 i 3 LIGHTING * P/S 20 1 .9 B 4 CASH REGISTER 20 1 .2 B •8KV 5 1 LIGHTING * P/S 20 1 .8 1 C 6 SPARE 20 1 C 7 LIGHTING * P/S 20 1 1.2 A 8 SPARE 20 1 A B28 --� 9 LIGHTING * P/S 20 1 1.2 B 10 SPARE 20 1 B 11 LTG GNL+REF 20 1 1.1 C 12 SPARE 20 1 C 13 EXTERIOR LIGHTING**TC 20 1 1.0 A 14 COFFEE STATION 20 1 1.5 A 5� CyV , 15 SPARE 20 1 B 16 COFFEE STATION 20 1 1.5 B r--� 830 17 LIGHTS, EXIT & EMERG. 20 1 .5 C 18 SPARE 20 1 C >� �---� 19 DISPLAY CASE BALLAST 20 1 1.0 A 20 SPARE 20 1 A 21 DISPLAY CASE BALLAST 20 1 1.0 B 22 SPARE 20 1 B 23 DISPLAY CASE BALLAST 20 1 1.0 C 24 SPARE 20 1 C 25 BACK LIT GRAPHICS 20 1 1.0 A 26 UNDERCOUNTER REFRIG. 20 1 .6 A 27 SPARE 20 1 B 28 REF & BACK BAR 20 1 1 .9 B 29 WP RECEPTACLES 20 1 .18 C 30 REF & BACK BAR 20 1 .9 C 31 EXTERIOR SIGNS 20 1 1.5 A 32 BELLS/BUZZERS/CLOCKS 20 1 .5 A L0 33 SPARE 20 1 1 1 B 34 IHAND DRYER 25 1 2.0 B Imo - 35 PYLON SIGN 20 1 1.0 C 36 SPARE 25 1 C p X 37 SPARE 20 1 A 38 GENERAL OUTLETS 20 1 1 1 1.5 A X 39 SPARE 20 1 1.0 B 40 GENERAL OUTLETS 20 1 1.5 B Z ^� 41 SPARE 20 1 C 42 TOASTER FAN 20 L11 6 f C ® m (/) LJ > ® m Lit d� .j U Q * P/S = PANEL SWITCHED w F- TCPOWER = TIME CLOCK CONTROL z SCALE: 1/4" = 1'-0" PANELBOARD "B" I I I T I VOLTAGE: 120/208 PHASE: 1 LOCATION: SEE PLAN BUS AMPS: XXX WIRE: 3 MOUNTING: SURFACE MAIN OVERCURRENT DEVICE: REMARKS: r CIRCUIT #M-2 AMPS: XXX CKT DESCRIPTION BREAKER LOAD CKT DESCRIPTION BREAKER LOAD fl/ AMP POLE KVA HAS AMP POLE KVA PHASE LJ- 1 COFFEE MAKER 40 2 3.5 A 2 COFFEE MAKER 40 2 3.5 A < Q 3 3.5 B 4 3.5 B < 0 5 COFFEE MAKER 30 2 1.6 C 6 SPARE 30 2 C �r-� Z 7 1.6 A 8 A I- L L_I LLj 1. POS TERMINAL INFORMATION: 9 SPARE 50 2 B 10 SPARE 30 2 B Z _I W - 110V AC DUPLEX OUTLETS 11 C 12 C ® 0� ^ W LL_I 2. RECEIPT PRINTER INFORMATION: NOTE: ELECTRIC LEGEND 13 SPARE 20 2 A 14 SPARE 20 2 A U V) - 110V AC DUPLEX OUTLETS ELECTRIC FOR THIS STORE IS EXISTING. PANELS AND CIRCUITS POS NOTE: - SHARED WITH TERMINAL OUTLETS SHOWN ARE FOR REFERENCE ONLY TO DETERMINE TOTAL GENERAL CONTRACTOR TO PROVIDE FOR P.O.S. SYSTEM AS SHOWN ON ELECTRICAL 15 B 16 B ® z - WIRED DIRECTLY TO TERMINALS LOADS REQUIRED. E.C. IS TO REVIEW EXISTING PANELS AND DRAWINGS OR, AT MINIMUM THE FOLLOWING CONDUITS: DUPLEX OUTLET 12" A.F.F. UNLESS NOTED OTHERWISE 17 ESPRESSO 30 2 1.55 C 18 ICED COFFEE BREWER 30 2 2 C Q 3. REMOTE PRINTER INFORMATION: WIRING AND REUSE WHERE PRACTICAL IF ALL STATE AND A) 2 1/ I.D. FROM 4x4x3 JUNCTION BOX LOCATED BEHIND OFFICE DESK UP THE WALL TO �x G=G X = NUMBER OF GANGED DUPLEXES IF MORE THAN ONE FI C=ABOVE COUNTER WP=WATERPROOF a :2 z a- n •. - 110V AC DUPLEX OUTLETS LOCAL CODES ARE MET. ABOVE CEE . ..ILING. 19 1.55 A 20 2 A � � - WIRED TO TERMINALS VIA RJ-45 B) 2 1/2" I.D. CONDUIT WITH 2'-0" SWEEPS AT ENDS FROM A HUB LOCATED IN THE 21 COOLATTA MACHINE 342 20 2 1.5 B 22 COOLATTA MACHINE 342 20 2 1.5 B J-BOX IN FRONT CABLE CHASE FRONT LINE CHASE UNDER SLAB TO THE BACK WALL. TERMINATE ABOVE CEILING. ® 23 TAYLOR 342 SIDE 1 1.5 C 24 TAYLOR 342 SIDE 2 1.5 C CO �- U O 4. VDU INFORMATION: C) 2"x4" ELECTRICAL BOX 6'-0" A.F.F. WITH 1" CONDUIT IN WALL TO ABOVE CEILING. POWER OUTLET - 208 VOLT, X = AMPERE - 110V AC DUPLEX OUTLETS FIXTURES MUST BE PURCHASED THROUGH A NATIONAL CENTER 32"02%3/4" PLYWOOD WALL BLOCKING IN WALL FOR VDU UNIT x 25 DUNKACCINO DISPENSER 20 2 1.7 A 26 SPARE 20 1 A ( ,� N/�/ - MOUNTING: WALL, CEILING, OR ACCOUNTS PROGRAM WITH VILLA LIGHTING SUPPLY INC., 1218 � THE MAXIMUM CONNECTION LENGTH BETWEEN A VDU AND ITS DEDICATED CPU IN THE TRANSIENT VOLTAGE SURGE SUPPRESSOR 27 1.7 B 28 SELF-SERVE COOLER 20 1 1.3 B LL_ L_L__ PEDESTAL S. VANDEVENTER, ST. LOUIS, MO 63110. PLEASE CALL FRONT LINE CHASE IS 75'-0". THE CONNECTION THEN GOES TO THE OFFICE. G.C. TO DUPLEX OUTLET 5. OFFICE AREA INFORMATION: MELANIE HURLEY, NATIONAL ACCOUNTS, AT 1-800-325-0963 29 BAGEL SIGN 20 1 •6 C 30 SELF-SERVE COOLER 20 1 1.3 C - 110V AC QUADPLEX OUTLETS I OR FAX 1-314-531-8720 FOR PRICING. PROVIDE SERVICE ONE I DN TELEPHONE JACK IN REG REGIONALLY AVAILABLE.THE OFFICE. NOTIFY DUNKIN DONUTS IF ISDN O JUNCTION BOX 31 SPARE 20 1 A 32 V.D.U. OUTLET 20 1 .8 A - 1 MODEM LINE REQUIRED FOR SUPPORT 33 TOILET EXHAUST FAN 20 1 .6 B 34 1 TV OUTLET 20 1 .8 B - 2ND MODEM LINE OPTIONAL FOR Ep FUSED DISCONNECT SWITCH 35 OFFICE 20 1 1.5 C 36 TRAINING MODULE 20 1 .5 C L j L-I CREDIT CARD PROCESSING ELECTRICAL PLAN KEYNOTES -i � _ " 37 OFFICE 20 1 1.5 A 38 UTILITY EXHAUST FAN 20 1 .9 A 6. NETWORK HUB INFORMATION: 1.REFER TO AWED DOMECQ ADQSR POS DEPLOYMENT METHODOLOGY" AND APPROVED VENDORS WALL CLOCK - EDWARDS #1882, 3g SOUND SYSTEM 20 1 •5 B 40 PRINCE WARMING #1 20 1 1.5 B- 110V AC DUPLEX OUTLETS FOR COMPLETE INFORMATION AND SPECIFICATIONS REGARDING POS SYSTEM INSTALLATION. 0 - LOCATED IN FRONT COUNTER Q EXTERIOR LIGHTS, PHOTOCELL ON, 11ME CLOCK OFF. 2.RETAIL INFORMATION SYSTEMS EQUIPMENT MUST BE ON DEDICATED CIRCUITS. R.I.S. EQUIPMENT MOUNTED 8'-0" A.F.F. 41 SPARE 20 1 C 42 PRINTER(S) 20 1 1.0 C CABLE CHASE MAY SHARE CIRCUIT'S WITH OTHER R.I.S. EQUIPMENT, BUT NO OUTSIDE EQUIPMENT SHOULD BE -® - CONNECTS TO TERMINALS, VDU'S, ® POWER FOR BACKLIT PANELS, SEE MANUFACTURER ON THESE CIRCUITS. F-TC-1 TIME CLOCK (BY OTHERS) SHEET BACK OFFICE COMPUTER SYSTEM FOR MOUNTING HEIGHT & LOCATION OF JUNCTION BOX. 3.ALL OUTLETS FOR R.I.S. EQUIPMENT SHOULD HAVE A THIRD WIRE ISOLATED GROUND. - ORDER INFORMATION ROUTED TO ® POWER FOR DISPLAY CASES, BALLAST TO BE 4-LOCATE ALL RECEPTACLES FOR R.I.S. EQUIPMENT WITHIN 4' OF THE EQUIPMENT THEY SERVE. FTI HAND DRYER (BY OTHERS) HUB, THEN TO VDU's & OFFICE MOUNTED IN THE DISPLAY CASE BASE. ALLOW 5.ALL R.I.S. DEVICES AT A REMOTE LOCATION FROM THE HUB SHALL REQUIRE CONDUIT 8' PIG TAIL " Q DOOR BUZZER - EDWARDS #115-4 WITH SWITCH 4 POWER FOR EXTERIOR SIGNAGE. REFER TO DEDICATED FOR R.I.S. USE. THE MINIMUM SIZE FOR ALL NETWORK CONDUIT IS 1-1/2 . ® 2 ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. 6.ALI.. NETWORK DEVICES REQUIRE CAT 5 CABLE WITH RJ-45 JACKS. A� BUZZER ALARM - EDWARDS #1065-65 W/592 1" 24 VOLT TRANSFORMER UNDER COMMON PLATE CONDUIT FOR UNDERGROUND LOOP FOR REMOTE 7.PROVIDE POWER CONDITIONERS / UNINTERRUPTED POWER SUPPLIES AS RECOMMENDED / NOTE: "P.O.S.", ALL POWER OUTLETS FOR P.O.S. DEVICES ARE DEDICATED CIRCUITS WITH 5 SPEAKER SYSTEM. VERIFY EXACT SIZE AND LOCATION REQUIRED BY APPROVED VENDORS AND ADQSR. " #55-AZ5, MOUNTED 8'-0" A.F.F. FILE 300331 , D05076 THIRD WrRE ISOLATED GROUND. AN IG IS AN INSULATED WIRE, SEPARATED FROM ALL ® WITH OWNER, SHALL NETWORK CABLING / CONDUIT MUST BE LOCATED A MINIMUM OF 12 FROM ANY � DOOR BELL - EDWARDS �� 01HER GROUND WRES, RUNNING BACK TO THE BUILDING MAIN OR COMPLEX POWER POWER FOR DRIVE-THRU WINDOW, SEE ELECTRICAL CONDUIT. ❑S BUZZER SWITCH - EDWARDS #� 4 DOOR CONTACT DATE:10/3/05 DUPLE. NE�1A STANDARD L5-15R I.G. FOR THE RECEPTACLE AND PLUG. USE OF IG � MANUFACTURER FOR MOUNTING HEIGHT & LOCATION 9.OPTIONAL TO EPHONE JACKS FOR OUTSIDE LINES MAY BE PROVIDED IN OFFICE AREA AND PREP El DOOR BELL BUTTON - EDWARDS 52 MANUAL FIRE ALARM PULL STATION TO BE INSTALLED IN DUPLEX OR QUAbPLEX OUTLETS: (I.E., HUBBELL IG-5262, 1G-5362 OR EQUIVALENT). A ACCORDANCE WITH GENERAL LAW. PR®�. MGR. J.R. _ OF JUNCTION BOX. AREA. C.M. B. FLANNERY GENERAL NOTES 1. FURNISH LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR THE PROPER AND COMPLETE INSTALLATION OF ALL ELECTRIC WORK SHOWN ON THE DRAWINGS AND AS HEREIN SPECIFIED. 2. ALL ITEMS NOT SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH ARE NECESSARY TO MAKE A COMPLETE ELECTRICAL INSTALLATION, SHALL BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. s>v_lu 0 3. ALL ELECTRICAL INSTALLATIONS AND GROUNDING SHALL BE IN STRICT ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE LOCAL, STATE AND NATIONAL CODES. 4. OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND INSPECTIONS. 5. MATERIALS AND WORKMANSHIP SHALL BE THE BEST OF THEIR RESPECTIVE KIND AND IN FULL ACCORDANCE WITH THE MOST MODERN ELECTRICAL CONSTRUCTION. ALL MATERIALS 0 20 21 8 SHALL BE NEW, EXCEPT WHERE NOTED ON THE DRAWINGS. 6. THE ELECTRICAL CONTRACTOR SHALL INSPECT THE SIGHT, PRIOR TO SUBMITTING HIS E 9 1$ 1 BID, AND SHALL INVESTIGATE ALL CONDITIONS UNDER WHICH THIS WORK WILL BE PERFORMED. FAILURE TO INSPECT EXISTING CONDITIONS OR TO FULLY UNDERSTAND Cy THE WORK WHICH IS REQUIRED SHALL NOT EXCUSE THE ELECTRICAL CONTRACTOR FROM HIS OBLIGATIONS TO SUPPLY AND INSTALL THE WORK IN ACCORDANCE WITH THE 1 DRAWINGS AND UNDER ALL SITE CONDITIONS AS THEY EXIST. 0 I 7. THE ELECTRICAL CONTRACTOR SHALL CLEAN AT THE END OF EACH DAY ALL AREAS I I WORKED IN. EMPTY BOXES, RUBBISH, AND OTHER MATERIALS OF NO USE SHALL BE 4 I REMOVED FROM THE BUILDING. ! ! I I 8. THE PLANS DEPICT THE LOCATION OF ALL DEVICES AND ARE INTENDED TO INDICATE 0 S I THE GENERAL INTENT OF THE WORK IN SCOPE, LAYOUT AND QUALITY OF WORKMANSHIP. SFE P .NOTE " I THEY ARE NOT INTENDED FOR THE PURPOSE OF EXECUTION OF THE WORK, BUT THE E.C. JB , " BELOW I 1 SHALL UNDERSTAND THAT SUCH DETAILS ARE PART OF THIS WORK. CEILI 4G I �o0 15 j 9. THE CONTRACTOR SHALL CAREFULLY VERIFY ALL MEASUREMENTS AT THE SITE. DETERMINED THE EXACT LOCATION OF ALL CHASES AND OPENINGS REQUIRED BY HIS WORK AND SHALL e o f� FURNISH AND SET ALL SLEEVE, INSERTS AND HANGERS AS REQUIRED FOR THE WORK HEREIN3: . ® 4A WALL MOUNTED 10. THE CONTRACTOR SHALL COORDINATE HIS WORK SO THAT IT DOES NOT INTERFERE WITH THE --- ` --`` - --� 5-11" A.F.F. (61" WORK OF OTHER TRADES. IT SHALL BE IN THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT U) e `\ 5 TO BOT. F VDU) HIS WORK IS INSTALLED IN A TIMELY MANNER. IIIIIIIINIIIII ee o SEE P.O.S. ®� J.B. ® CEILING, CONDUIT 11. THE CONTRACTOR SHALL INSTRUCT THE OWNER OR THE OWNER'S REPRESENTATIVE IN THE 00 e` NOTE'"* DOWN TO 42" A.F.F. PROPER OPERATICN OF ALL EQUIPMENT. THE CONTRACTOR SHALL FURNISH TO THE OWNER ALL N M oo LITERATURE FURNISHED BY THE MANUFACTURER AND DEMONSTATE PROPER OPERATION AND a at 0 rl- .q- ~o� ®\ MAINTENANCE. � >` 12. ALL WORK SEQUENCES SHALL BE COORDINATED WITH THE ARCHITECT AND SHALL BE IN Lo N _ - ------ ---- I COORDINATION WITH OTHER BUILDING TRADES AND ARCHITECT BUILDING SCHEDULES. ® Lj to ----- / 13. ALL ELECTRICAL, LIGHTING DEVICES SHALL BE INSTALLED IN ACCORDANCE j' ®\ 7 WITH THE ADA (AMERICANS WITH DISABILITIES ACT). H 0 � 14. ALL BRANCH CIRCUITS RATED AT 120 VOLT, 20 AMPERE EXCEEDING 75 FEET SHALL BE 0 (n U-) SEE P.O.S. a MINIMUM #10 AWG. d w W .. NOTE "B" oe 11 16. ADDITIONAL JUNCTION BOXES BEYOND THOSE SHOWN SHALL BE PROVIDED AND INSTALLED AS <L z Ne NECESSARY, m0 m LL e 6 15. ALL CONDUITS SHALL CONTAIN A GREEN SAFETY GROUND WIRE. BOND ALL PANELS, CABINETS, C- --- - -- ENCLOSURES, CONDUITS, ETC., AS REQUIRED. P P 1 16. RECEPTACLES, LIGHT FIXTURES AND POWER ITEMS BRANCH CIRCUIT WIRING MAY NOT BE I ! SHOWN BUT SHALL BE PROVIDED AS REQUIRED. MINIMUM WIRING SHALL BE 3/4'C-2 #12, 1 #12 GROUND. NO MORE THAN THREE PHASES MAY BE COMBINED IN A SINGLE HOMERUN AND EACH PHASE SHALL BE PROVIDED WITH AN INDIVIDUAL NEUTRAL 17. ALL CUTTING, PATCHING AND FIRESTOPPING FOR ELECTRICAL INSTALLATION SHALL BE THE -- - - -' NETWORK WIRING FOR RESPOSIBILTY OF THIS CONTRACTOR. 2A 1 9B 1 2 VDU's ABOVE CEILING 18. PROVIDE CONDUIT SLEEVES FILLED WITH AN APPROVED FIRE RESISTANT MATERIAL WHERE OVER TO WALL CONDUIT. FIRE RATED WALLS OR CEILINGS ARE PENETRATED. APPROVED WATERTIGHT CONDUIT SLEEVES 1 12 9A 12 SHALL BE PROVIDED WHERE WALLS ARE PENETRATED EITHER ENTERING OR LEAVING THE BUILDING. 19. ALL FLEXIBLE METAL CABLE TO BE USED IN THIS PROJECT SHALL BE AFC HCF-90 OR APPROVED EQUAL WHERE PERMITTED BY THE NEC AND THE LOCAL AUTHORITY HAYING JURISTRICTION. 20. FOR MORE INFORMATION REGARDING THE ELECTRICAL REQUIREMENTS FOR THE EQUIPMENT SHOWN, REFER TO THE EQUIPMENT SCHEDULE OUTLETS FOR MUSIC AND SECURITY up (OPTIONAL) �v � CC CC OS SHELF 18 BACK ELEVATION FRONT ELEVATION 8 g REMOVABLE _Sp{� � 2 1 1 1 1 PANEL t t ��..®m 9 r CD PO OS PO PO . t VOICE o ® X to on a +i I ® 11 t f < F-iiww w PC ® m 0 FRONT LINE POS COUNTER CAD DUNKIN' AREA OFFICE SCHEMATIC > Z LJ > ® =) LiJ POS TERMINAL � L HOLE PLACEMENT PLAN VIEW U 10' 10"SERVICE SIDE til LOW VOLTAGE PLAN0 o 1 NOTE: A LL SCALE: 1/4" = 1 -®ff Z ALL CEILING MOUNTED VDU'S TO BE SUSPENDED FROM 29 _T UNISTRUT BY THREADED ROD W/ WHITE PVC SLEEVE. CUSTOMER SIDE CONNECT UNISTRUT TO ROOF STRUCTURE. VDU BY POS VENDOR; UNITSTRUT & THREADED ROD BY G.C. UNISTRUT TO SUPPORT MINIMUM 50 LB. WEIGHT POS - COMMUNICATIONS EQUIPMENT SCHEDULE POS - NOTES KEYNOTE REQ"D DESCRIPTION - LCGATION VOLTS AMPS TRANSFORMER LOVO EXCEPTIONS/ GENERAL NOTES < LLJ ` QTY TERM NOTES 11 1 JOURNAL PRINTER DD POS- UNDER COUNTER 120V 95 NO SERIAL ECR 1. REFER TO www.adrus.com/extronet FOR A LISTING OF -� 9 PIN APPROVED POS VENDORS BY CONCEPT.POS EQUIPMENT 12 X CASH DRAWER UNDER COUNTER-ALL POS N/A N/A N/A RJ45 DT ON TOE' OF COUNTER 2. FINAL E3 DRAWINGS NEED TO BE PROVIDED TO POS z W F d EXCLUDING DT & ORDER TAKER DT OT DOES NOT GET A CASH DRAWER VENDOR THAT IS SELECTED. 0 w 1 X POINT OF SALES TERMINAL (POS) X FRONT LIRE, X DRIVE-THRU 100-120V 2.0 NO RJ45 I= I- U OTHER COMMUNICATIONS DEVICES 3. POS VENDORS REQUIRE DEDICATED ISOLATED GROUNDED < � Li 1A 4 0v POINT OF SALES TERMINAL (POS) 1 ORDER TAKER 100-120V 2.0 NO RJ45 PROVIDE CONDUITS (DUPLEX POWER (DIG) OUTLETS ON A 20 AMP CIRCUIT DEDICATED ONLY TO U W J (FUTURE/OPTIONAL) & LOW VOLTAGE), PULLSTRING & 15 POS EQUIPMENT. 60Hz, 120+/-1076. ALL POS TERMINALS ® Z f li COVERPLATES ``J RECEIPT PRINTER X FRONT LINE, X DRIVE-THRU 100-240V 2,0 YES RJ45 UNDER COUNTER FOR ALL EXCEPT 16 AND VIDEO DISPLAY DEVICES REQUIRE A DUPLEX OUTLET.THE BACK OFFICE CONTROLLER REQUIRES A QUAD OUTLET. ® :24 - THE NETWORK SWITCH REQUIRES A DUPLEX. IF FEDERAL, D.T. (ON TOP OF COUNTER) _ 17 STATE, AND LOCAL WIRING CODES DO NOT MEET THIS N < _ 2A 0 RECEIPT PRINTER (FUTURE/OPTIONAL) X FRONT LINE 100-120V 2.0 NO RJ45 REQUIREMENT, CONTACT THE POS VENDOR FOR cp PHONE & DATA LINES INFORMATION ON ADDITIONAL EQUIPMENT THAT CAN BE .. 3 1 ORDER/PREP PRINTER-IMPACT 1 DD PREP, X BR BACKLINE 24/34V 1.2 YES RJ45 PURCHASED TO MEET THIS REQUIREMENT. IF THIS -.u-- 18 1 DATA/MODEM FOR POS OFFICE LOW VOLT N/A N/A RJ45 ECR/ PC EASED SUPPORT LINE REQUIREMENT IS NOT MET, THE POS SYSTEM WARRANTY IS 4 0 VDU 100-240V 1.5 NO N/A INVALID. -- ------ -�-� " 18B 1 ECR DATA/MODEM FOR POS OFFICE LOW VOLT N/A N/A RJ45 RUN ECR DATA/ CC DATA LINE FROM 4. ALL POWER INDICATED ON THIS PLAN MUST HAVE A THIRD 4A X VDU CPTIONAL) - 1 DD PREP 100-240V 1.5 NO N/A BOTTOM OF SANDWICH STATION VDU ® 68 OFFICE/ HIGH SPEED ROUTER LOCATION TO WIRE, ISOLATED GROUND, AND BE TERMINATED WITHIN (4) LLJ MOUNTING: WALL 1 DRIVE-THRU COFFEE BOTTOM OF DT VDU ® 61 POS NETWORK HUB 1 BR BACKLINE BOTTOM OF BR VDU ® 48" TO 60" FEET OF THE DEVICE. r� 19A 1 DATA/MODEM FOR CREDIT OFFICE LOW VOLT N/A N/A RJ45 PC BASED POS SYSTEM CREDIT 5. IG-5362 RECEPTACLES MUST BE USED FOR ALL POS �J 5 CARD PROCESSING DEVICES. LABEL RECEPTACLES "POS ONLY". 0 Li 5A X VDU CONTROLLER (PC BASED) 1 DD PREP 100-120V 1.0 YES RJ45 19B X DATA/MODEM FOR CREDIT X FRONT LINE, X DRIVE-THRU LOW VOLT N/A N/A RJ45 ECR POS SYSTEM CREDIT; 1 DRIVE-THRU CARD PROCESSING RUN ECR DATA/ CC DATA LINE FROM 6. LOW VOLTAGE WIRE IS REQUIRED TO BE CATEGORY #5 OFFICE/ HIGH SPEED ROUTER LOCATION TO CABLE RUN IN iXz" RIGID CONDUIT NTH PULLSTRING FOR 5B 0 VDU CONTROLLER (ECR) 100-120V 1.0 YES RJ45 POS NETWORK HUB POS EQUIPMENT ONLY, AND MUST BE TERMINATED WITH 6 1 POS NETWORK HUB/ SWITCH POS COUNTER FRONT CHASE 100-120V 0.5 YES RJ45 20 1 FAX LINE OFFICE LOW VOLT N/A N/A RJ45 RJ-45 JACKS. SHEET 7. A 12 MINIMUM SEPARATION MUST BE MAINTAINED 7 w 1 PC SITE CONTROLLER OFFICE 100-120V 4.0 NO RJ45 21 1 PHONE LINE OFFICE LOW VOLT N/A N/A RJ45 BETWEEN LOW VOLTAGE WIRES AND POWER WIRING (TO 7A I ECR SITE CONTROLLER POS COUNTER 115-230V 0.2 YES RJ45 22 1 PHONE LINE TRAINING (IF APPLICABLE) LOW VOLT N/A N/A RJ45 AVOID ELECTRICAL INTERFERENCE). EQUIPMENT NOTES 7B 1 ECR MODEM POS COUNTER 100-120V 0.2 YES RJ11/ 45 N/A 0 PHONE LINE OFFICE (COMPUTER LINE) LOW VOLT N/A N/A RJ45 1. VDU HEIGHT TO BE COORDINATED WITH EQUIPMENT AND �- 7C 1 ECR IP CONVERTER POS COUNTER 100-240V 0.2 YES RJ45 N/A 0 FAX LINE OFFICE LOW VOLT N/A N/A RJ45 SIGNAGE (SEE ELEVATIONS). 8 1 PRINTER (BACK-OF-HOUSE) OFFICE 100-120V 8.2 NO N/A PC BASED POS SYSTEM N/A 0 PHONE LINE OFFICE LOW VOLT N/A N/A RJ45 2. ONLY REQUIRED EQUIPMENT IS VISUALLY REPRESENTED FILE :300331 , D05076 AND TAGGED IS SHOWN ON THIS FLOOR PLAN. OPTIONAL DATE:10/3/05 9 1 MODEM (EXTERNAL) OFFICE 120V .2 YES N/A PC BASED POS SYSTEM N/A 0 PHONE LINE SECURITY SYSTEM LOW VOLT N/A N/A RJ45 EQUIPMENT IS TAGGED BUT NOT SHOWN GRAPHICALLY. -�--�------ 1 MODEM (INTERNAL) _ POS COUNTER FRONT CHASE 120V .2 YES N/A FOR ECR CREDIT, LOCATED INSIDE #7B N/A 1 DSL/CABLE/ISDN/SATEWTE OFFICE LOW VOLT N/A N/A RJ45 INTERNET/ FUTURE POLLING/ RADIANT PROJ. M GR. J.R. C.M.B. FLANNERY II I I I i 1 r SYMBOL LIST —�— GATE VALVE -- --- GAS COCK PLUMBING FIXTURE SCHEDULE o 'ea C.W. - COLD WATER H.W. - HOT WATER MARK DESCRIPTION WASTE VENT COLD HOT C) WATER WATER �®® G GAS PIPING INSIDE FOR APPLIANCES P 1 WATER CLOSET 4" 4" 1/2" I RG GAS PIPING OVER ROOF FOR HVAC I P 2 LAVATORY 2" 2" 1/2" 1/2" 0 ---------- _ MIXED HOT COLD WATER PIPING H.B. HOSE BIBS P 3 MOP SINK 3" 3" 1 2" 1 2" s H.V.A.C. HEAT VENT AND AIR CONDITIONING UNIT p 5 HAND SINK SINK 1 1/2" 11/2" 1/2" 1/2" U) - - A.F.F. ABOVE FINISH FLOOR * 2 cy p 6 BACK BAR SINK 1 1/2" 1 — �® TOCOLD U.N.O. UNLESS NOTED OTHERWISE — -- ®a -_j I WATER SUPPLY * SINK PROVIDED AS PART OF EQUIPMENT PACKAGE - IN BASEMENT PLUMBER TO MAKE FINAL CONNECTIONS. P 4 ' TO WATER GENERAL NOTES I HEATER IN P 5 ° BASEMENT I 1. ALL PREP AREA AND SERVING AREA EQUIPMENT WILL BE FURNISHED AND INSTALLED EXCEPT AS NOTED, (SEE K2 SHEET, EQUIPMENT _ _ --�- --- "---`- --- SCHEDULE). EQUIPMENT WILL BE FURNISHED WITH TRIM AND FAUCETS, EXCEPT AS NOTED. PLUMBING CONTRACTOR SHALL --- PROVIDE ALL ROUGH-IN TRAPS AND MAKE ALL FINAL CONNECTIONS. ' P 3 ' P 6 2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL GAS ' I PIPING AND MAKE ALL FINAL CONNECTIONS. GAS PIPING TO BE P 2 P 1 q ljj SCHEDULE 40 BLACK STEEL PIPE AND BANDED MALLEABLE IRON '- I U) FITTINGS. 3. ALL PIPING IS SHOWN DIAGRAMMATICALLY, EXACT LOCATIONS SHALL � BE DETERMINED IN THE FIELD. EQUIPMENT LOCATIONS ARE to n APPROXIMATE, COORDINATE EXACT LOCATIONS WITH ALL TRADES ® I D-- - I BEFORE INSTALLATION. 4. ALL PIPING SHALL BE RUN CONCEALED UNLESS OTHERWISE NOTED. uj ray <C �1 00 5. ALL UNDERGROUND WATER LINES SHALL BE TYPE "K" COPPER co m � 8T P 6 TUBING WITH 1/2 THICK ARMAFLEX INSULATION. L toI 6. ALL ELEVATIONS SHALL BE VERIFIED AT THE JOB SITE. x 13 1 r0 7. PROVIDE BACK-FLOW PREVENTER AT THE LOCATIONS REQUIRED BY o moo I 1 I CODE AND ALL GOVERNING AUTHORITIES. . � Lo 8. COORDINATE AS REQUIRED TO ASSURE PROPER AND ADEQUATE O Z ., u- I PROVISIONS IN THE WORK OF THE OTHER TRADES FOR INTERFACE � „ WITH THIS SYSTEM. m OQ 9. ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE g a l ARCHITECT. I10•SEE W SHEET(S) FOR EQUIPMENT CONNECTION REQUIREMENTS. I 9 11.ALL SANITARY UNDER SLAB PIPING SHALL BE PVC. 12.ALL ABOVE SLAB VENT & DRAINAGE PIPING SHALL BE CAST IRON 1L OR COPPER. (PVC CAN BE USED IF ALLOWED BY LOCAL CODES). 13.IF WATER FILTRATION SYSTEM IS USED, BRANCH OFF MAIN LINE, FOR I COFFEE BREWING EQUIPMENT, ICE MACHINE, POST MIX. I I - -J FIRST FLOOR LINE MAY RUN UP OUTSIDE OF WALL OF EXTERIOR G G G WALL i I PLUMBING IN THIS STORE IS EXISTING. REUSE I HW WHERE POSSIBLE. UPGRADE TO MEET ALL i i U7 APPLICABLE STATE AND LOCAL CODES. i i II''I- O CONNECT NEW PLUMBING TO EXISTING. GAS METER I I HVAC 1 ® x BASEMENT FLOOR LINE Z } 0m (n l ® UJI N Lij 0-1 (A HOT COLD WATER & GAS PIPING PLAN GAS PIPING RISER DIAGRAM lz SCALE 1/4"=V-0" Li CD (f) W Q LLJ Z Li.J V J 1- 1" 3/4" 3/4- 1" 1" 1- / ! LLI HW -- ---- --------- -------- ------ ------- ------------ ------ -------------------------- --------------- ----------- ---- ----- -------- V J CW - ----- --- - --- ----- ---- ----- ----- - -------- -- ---------------------- ------------- ------- -------- ------ O r- ---� - T- - T- j !� �f ----- --------- ------ ------ - 1 0 r 0- CEILING LINE 1" 1/2" 1/2" I , 1/2" ° 1/2" I 1/2" I 1/2"' I , 1/2" 3/4" 13/4" I 1/2" ' 1/2" ' 1/2" 1/2-1 I 1/2"1 F APPLICABLE I I `� 1 e I A L.I T I , I I � I.C. s ICE I BREW 6 1 I I I l e � ESPRESSO I DUNK. I I I I O I 1 "W I � I ' � � I , o , WATER FRONT LINE CASEWORK, I I I I I I POT SINK FILTERS) T I COFFEE MAKERS, ETC. TOILETrumat —I I I i I 0 I (OPTIONAL) 1 1/2" 1/2" 1 " I I 0- I , OUTSIDE MOP HOT WATER HAND ;,� I , 1/2 1" MIN. HOSE BIBB I LAVATORY SINK HOSE BIBB SINK FLOOR LINE ' METER E= u ' —_� SHEET -•�-- _ P1 P2 P3 P4 P5 --® --- P6 P6 TO SITE OR NOTE: 1" IF TO FRONT LINE BACK BAR BACK BAR MUNICIPAL FLUSHOMETER CASEWORK SINK SINK WATER SERVICE I HOT 8c COLD WATER RISER DIAGRAM- FI LE :300331, D05076 DATE:10/3/05 PROJ. MISR. J.R. -���--- - - C.M. B. FLANNERY 01 o o u SYMBOL LIST--ME- SANITARY WASTE PIPING BELOW SLAB BAXTER PROOFER AND/OR �- GREASE WASTE PIPING BELOW SLAB RACK o OVEN DRAIN NOTE ---- ---�-- - - - VENT PIPING BELOW SLAB _ VENT PIPING ABOVE SLAB DRAIN = 1/2" NPTF PIPE THREAD LEFT REAR DRAIN 0 5"AFF, I I OEM GREASE TRAP ROUTE TO AIR GAP FLOOR DRAIN, CONNECT USING FITTING TO 0 F.C.O. FLOOR CLEAN OUT ENABLE USE OF BRAIDED LINE FOR FINAL DRAIN LINE. H.O. HUB OUTLET 0r _ -.- �- F.D. FLOOR DRAIN - W/AIR GAP CUP r----- -- -i F.S. FLOOR SINK - W AIR GAP - SAFE WASTE I I V.R. VENT RISER C.O. V.T.R. VENT THRU ROOF P 4 I.W. INDIRECT WASTE El I P 5 A.F.F. ABOVE FINISH FLOOR U.N.O. UNLESS NOTED OTHERWISE it t / PLUMING FIXTURE SCHEDULE LHMARK DESCRIPTION WASTE VENT COLD HOT AAk P 2 P 1 F.D. WATER WATER I . P 1 WATER CLOSET 4" 4" 1/2" 00 I I I \` P 2 LAVATORY 2" 2" 1/2" 1/2" (o M i o- il P 3 MOP SINK 3" 3' 1/2" 1/2" Ask ® � tt I t 00 P 4 POT SINK 3" 3' 1/2" 1/2" V) d 100 I -A- P 5 HAND SINK 1 1/2" 1 1/2" 1/2" *2"; " oo m N I I P 6 * P 6 BACK BAR SINK 1 1/2" 1 1/2" 1/2" J to c I Iom* SINK PROVIDED AS PART OF EQUIPMENT PACKAGE - m Q 0 co PLUMBER TO MAKE FINAL CONNECTIONS. I- m X ® En u) C.O. I U) a' Z l.. GENERAL N OTES m Q_ I 1. ALL PREP AREA AND SERVING A EQUIPMENT FURNISHED INS AIL ED EXCEPT AS K2SHEET EQUIPMENT AND i F.S. F.S. SCHEDULE). EQUIPMENT WILL BE FURNISHED WITH TRIM AND FAUCETS, EXCEPT AS NOTED. PLUMBING CONTRACTOR SHALL gaw PROVIDE ALL ROUGH-IN TRAPS AND MAKE ALL FINAL CONNECTIONS. I 2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL GAS I PIPING AND MAKE ALL FINAL CONNECTIONS. GAS PIPING TO BE SCHEDULE 40 BLACK STEEL PIPE AND BANDED MALLEABLE IRON i FITTINGS. I� 3. ALL PIPING IS SHOWN DIAGRAMMATICALLY, EXACT LOCATIONS SHALL BE DETERMINED IN THE FIELD. EQUIPMENT LOCATIONS ARE APPROXIMATE, COORDINATE EXACT LOCATIONS WITH ALL TRADES BEFORE INSTALLATION. 4. ALL PIPING SHALL BE RUN CONCEALED UNLESS OTHERWISE NOTED. C,ys� t`®1 TO MUNICIPAL TO EXTERIOR 5. ALL UNDERGROUND WATER LINES SHALL BE TYPE "K" COPPER SEWER GREASE TRAP TUBING WITH 1/2" THICK ARMAFLEX INSULATION. L -t I 6. ALL ELEVATIONS SHALL BE VERIFIED AT THE JOB SITE. W. i 7. PROVIDE BACK-FLOW PREVENTER AT THE LOCATIONS REQUIRED BY CODE AND ALL GOVERNING AUTHORITIES. S. COORDINATE AS REQUIRED TO ASSURE PROPER AND ADEQUATE PROVISIONS IN THE WORK OF THE OTHER TRADES FOR INTERFACE PLUMBING IN THIS STORE IS EXISTING. WITH THIS SYSTEM. REUSE WHERE POSSIBLE. UPGRADE TO MEET 9. ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT. ALL APPLICABLE STATE AND LOCAL CODES. 10. SEE 'K' SHEET(S) FOR EQUIPMENT CONNECTION REQUIREMENTS. CONNECT NEW PLUMBING TO EXISTING. ADD FLOOR DRAINS AS NECESSARY IN PREP 11. ALL SANITARY UNDER SLAB PIPING SHALL BE PVC. AREA, VERIFY WITH OWNER. 12. ALL ABOVE SLAB VENT & DRAINAGE PIPING SHALL BE CAST IRON ® x Pi OR COPPER. (PVC CAN BE USED IF ALLOWED BY LOCAL CODES). V) x Z } Q O m (n Lj ® � � CL ICI � IiJ ~ Sol-L, WASTE & VENT PLAN nz C5 SCALE 1/4"=1'-0" Uzi I s so 6� V.T.R. 71cf) 1 4" LLJ [-- Li Jj 0 CD 3" _------------------ e°i 1I _j --------------------------------------------------------------------------.-------___--- ---------------------------__--------.__—®_--J ° fl r-----------------------------------7r---------------------------------T7---------------- -----n--ter--ter ------ 7�--------- sr------ter--- I I of rs °°i of �r er ri rr ee er re ei I I W er ri o ee r eo ei ei ei ei ei ri I I I I ei ei o°i si °i ff ei ✓i ri ri er ei i CEILING LINE - - II I! II II � Lu '-ff- II t I I I ® � I I II II II II g t I I 11 11 it 11 U/ It 11 I g I I I I 11 I I I I I I I I I I I I I I V! ll II I I U II II I I II 1 j " !1 II II II I1 Ij Ij ! I I 11 2" 11 2' I 13" 11 1 1 2" 1 1 3 Ill 1 1/2' t l 2" I 12" I 12" Ill 1/2" 1 12' 1 12' 1 1 4" It 11 I g II / II It I ►) II I " I i I ii I! II II ii ' ® I II !i II II II II fl it Ij I I CD 1! 9f II II I! II II I I N I I 11 P5 ICE BACK BAR I I I I I I BACK BAR LAVATORY j I I co II II I HAND P4 II II II SINK SINK II II II SINK P2 II P1 Z II II I I POT SINK II II II It li Ll II II tl II TOILET W ALL FLOOR DRAINS IN P3 II II II ;I o N PREP, STORAGE & H.O. UTILITY ROOM AREAS. MOP SINK W F.D. F.D. 2' F.S. F.S. F.S. F.D. r n FLOOR LINE 1 1/2„ GREASE TRAP, 1 1/2' 4' 4" 4" 1 1/2' 2' 4" 4" y J SEE DETAIL 2/P4 4„ 4„ 3" 2" W 4" TO SITE OR F.C.O. MUNICIPAL SHEET SEWERAGE TO SITE GREASE TRAP SOIL, WASTE , VENT RISER DIAGRAM- FILE#:300331, D05076 R DATE:10/3/05 I PROJ. MGR. J.R. I C.M. B. FLANNERY IF ADDITIONAL INTERIOR GREASE TRAP IS REQUIRED: 2 VENT I � I N WALL 3 V PROVIDE CLEANOUTS IN DISCHARGE INTO RECEPTOR COLD WATER SUPPLY PIPE HANGER THREE COMPARTMENT SINK WITH LEVER WASTES. �---- O � CLEANOUT TURNS/ENDS OF PIPE. UU WITH AIR GAP SUFFICIENT TO WATER HEATER. �� NEXT TO PIPE TEE DWV FITTINGS IF SIZE TO REMOVE GRATE AND PIPE UNION: SHUT-OFF VALVE ?-- O on ¢� p ,14 RANCE REQD FO SHUT-OFF IS LARGER THAN 1". STRAINER. MINIMUM GAP = DIELECTRIC IF SLOPE PIPE G® TWICE PIPE DIAMETER. DISSIMILAR METALS 2T CA NO. 530 LIBRATED t TRAINER REMOVAL VALVE AS MUCH AS �p VI�ELDED STEEL EXPANSION PRESSURE FLOOR I 2" 2" G 2" TOWAPOSSIBLE RD TANK WITH POLYPROPYLENE RELIEF VALVE I UNING FDA APPROVED FOR SET AT 100 PSI. REMOVABLE GREASE SAMPLING DISCHARGE. ' �O I DOMESTIC WATER SERVICE. 15 RECEPTACLE PORT MAKE CONNECTION HARD COPPER �3" TO EQUIPMENT BUTYL DIAPHRAGM -� f RELIEF VALVEa I AS REQUIRED. DISCHARGE LINE LOCATE GREASE TRAP IN CONVENIENT LOCATION, WHERE STRAINER > AIR CHARGING VALVE. �- TO END OVER CAN BE EASILY REMOVED FOR CLEANING AND GREASE RECEPTACLE MAKE PIPE MINIMUM ONE SIZE VERIFY WITH LOCAL FILL TANK WITH AIR ET CAN BE REMOVED FOR WASTE DISPOSAL. LARGER THAN EQUIPMENT CON- CODES IF/WHEN TRAP O FLOOR DRAIN OR to PRESSURE TO MATCH JANITOR'S SINK. Cy NECTION, MINIMUM 3/4". USE -M AND/OR VENT ARE RE- PATER PRESSURE, AIM DOWNWARD, GREASE TRAP IS THERMACO BIG DIPPER MODEL OR L" HARD COPPER UP TO 1 QUIRED FOR THE LENGTH THEN OPEN VALVE. — WITH 2" AIR GAP #W-250-IS, 25 GAL/MIN, 2" IN & 2" OUT. AND TYPE DWV FOR LARGER. OF DRAIN PIPE INSTALLED. ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS PIPE, MEET LOCAL CODE REQUIREMENTS. HUND SINK ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY. HANG PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT CAST IRON PIPE, FITTINGS AND CONNECTORS ALL AROUND SINK PIPE AS REQUIRED. DO NOT INSULATE INDIRECT DRAIN PIPE FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. AND TRAP. CONNECT GREASE TRAP FROM CENTER PROVIDE WHEN INSTALLED EXPOSED IN FOOD SERVICE FACILITY. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION P-TRAP IF GREASE TRAP IS MORE THAN COMPARTMENT: 4' FROM SINK. REFER TO LOCAL CODES FOR FURTHER INFORMATION. PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. NOTE: COORDINATE INDIVIDUAL BAY DRAINAGE , AIR GAP, & DRAIN FUNNEL WITH LOCAL CODE REQUIREMENTS. 1 NOT SED 2 UTILITY SINK AND GREASE TRAP 3 CONDENSATE DRAIN 4 EXPANSION TANK 5 NOT USED ___T I= NOT TO SCALE Em NOT TO SCALE NOT TO SCALE NOT TO SCALE HOT WATER TO FIXTURES COLD WATER SUPPLY m I NOTE INDIVIDUAL FILTERS THIS DETAIL IS TYPICAL EQUIPMENT dP-3C"FILTER SYSTEM AS SHOWN ON PLANS ---.�_gi ��TO WATER HEATER. M ALSO PROVIDED FOR FOR ALL COMBOS `NI DESCRIPTION PORT A PORT B ® NPOgt- PROOF ERS - COORDINA DUNKIN' DONUTS DUAL BREV°�'ER; WALK-UP X PROVIDE FULL PORT BALL 1/2" COLD WATER THERMOMETER I ' PROVIDE A 210' F O � I Vk'/ EQUIPMENT PRESENT AND AT ALL DRIVE THRU POST MIX X SHUT-OFF VALVE ON ROUGH-IN. SUPPLY DOWN IN ASME APPROVED V) < I m SPECIFICATIONS ' PARTITION WHERE PROVIDE FULL PORT BALL TEMPERATURE AND 00 M rid 1 .� DUNKIN DONUTS DRIVE THRU CARBONATOR X DOUBLE CHECK VALVE DCV SHUT-OFF VALVES — 150 PSI PRESSURE L() CD 04 INDIVIDUAL STORES SHOWN ON PLAN. DUNKACCINO MACHINE X INSTALL WATER RELIEF VALVE W ADAPTER AND SIX PROVIDE PIPE WITH •TEST LEVER, cn I I DUAL BREWER; DRIVE-THRU X FILTER PER MAN- ® m I ICED COFFEE BREWER X UFACTURER°S FOOT LONG IF REQUIRED FOR SIZED WITH CAPACITY m .- ® 00 0 UNIONS, I I INSTRUCTIONS SOFT COPPER PER WATER HEATER F- � O SELF SERVICE POST MIX X TUBING TO CURER DISSIMILAR METALS. MANUFACTURER'S O (n � IF FURNISHED CURER z ' INCOMING CUNO WATER SELF SF�iVICE CARBONATOR X WITH ICE MACH. WATER INLET. RECOMMENDATIONS. � Ld .. DOMESTIC WATER FILTRATION CONNECT TO GAS-FIRED WATER d I $ SU) ERVICE SYSTEM DECK OVEN X INSTALL WHERE MULTIPLE CUBERS G m HEATER PER SPECS O ACCESSIBLE. AND SCHEDULE. PROVIDE A HARD = ICE MAKER X WHERE REQUIRED. ® COPPER RELIEF a- INDIRECT DRAIN BURNER THERMOSTAT VALVE DISCHARGE OPEN TO AT- ICE BIN CONNECT TO CURER AND PRESSURE REGU- LINE FULL SIZE OF COFFEE MOSPHERE AT AND ICE BIN DRAIN LATOR FURNISHED VALVE OUTLET TO I - UPPER END. 3/4» OUTLETS AS REQ D. WITH WATER HEATER. END OVER JS NOTE: 1" REFER TO "INDIRECT WITH 6" AIR GAP. I MINIMUM STORE 2" FS DRAIN" DETAIL FOR GAS SHUT-OFF COCK PRESSURE TO ID -4;4 MORE INFORMATION. WITH LEVER HANDLE -emu O O & GROUND JOINT UNION o< DRAIN VALVE BYlp B ICE FILTER IS 45 PSI El PROVIDE FLOOR SINK AT FRONT EDGE OF ICE 6" LONG DIRT LEG -� HEATER MANUFACT. WITH TOP 1/2" MACHINE, WHERE ACCESSIBLE FOR CLEANING - NOT I BELOW FLOOR. UNDER ANY EQUIPMENT. SLOPE FLOOR 1/2" TO RIM. PROVIDE WATER- \SET WH ON PLATFORM PRE-FILTE WATER SERVICE TO ALL POST MIX PROVIDE COLD WATER ROUGH-IN AT TOP OF ICE MACHINE. TIGHT GALVANIZED (PLATFORM BY OTHERS) G.C. TO SHEET METAL OTHER POINTS OF USE - (AS FURNISH AND ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO PAN 2" DEEP WITH TOILETS, SINKS, ETC. REQUIRED) INSTALL WATER SUIT CONDITIONS. VERIFY CONNECTIONS WITH MANUFACTURER. 1" DRAIN PIPE TO JS PIPING SHOWN IS SCHEMATIC. PROVIDE CLEARANCES RECOMMENDED BY MANUF., ---� FILTER SEISMIC STRAPPING. SET THERMOSTAT AT 1207. WATER FILTRATION SYSTEM 7 ICE MACHINE CONNECTIONS 8 RACK WASH AREA 9 GAS WATER HEATER NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE T_ NOTE: H W CW HOT WATER SHUT OFF SHUT WATER BY GAS COMPANY (VERIFY) < BY PLUMBING CONTRACTOR TEMP: 130-150 DEG. F VALVE VALVE PRESSURE: 30-60 PRESSURE TEST COCK EXTERIOR BUILDING WALL. PSIG " GAS METER OF CFH GAS PIPE UP ONTO ROOF. SIZE: 1/2 WATER CAPACITY SHOWN G LOOP PIPE OVER PARAPET. COLD WATER CHILLER �- ON PLANS SIZE AS SHOWN ON PLAN. PRESSURE: 30-60 ®oa TEMP ,®,TEMP ® X USE BLACK STEEL PIPE. I PIPE IN ANCHOR RISER TO WALL AT PSIG SIZE: 1/2" TEN FOOT INTERVALS USING PRESSURE GAUGE AUG CREASER (n X OFFSET RISER PIPE CLAMPS. REGULATO ' PRESSURE REGULATOR I � PIPE INCREASER AND UNION PRESSURE I BYPASS VALVES GAUGE I I PRESSURE � w STRAINER GRADE OR LEG DE 6" LONG I I GAUGE ® V) AT BOTTOM OF RISER.9 PAVEMENT STRAINER STRAINER L� F= V) ry rZ I G FLOOR CHECK I I CHECK U Q PRESSURE REGULATOR TO REDUCE PRESSURE TO 14" WC. VALVE I WATER I VALVE U) F- TYPICAL SHUT-OFF VALVE METER p VERIFY REQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY. I ; O Q INSTALL OTHER UTILITIES MINIMUM TEN FEET FROM GAS LINE. PLUMBING CONTRACTOR SHALL PAY ALL GAS COMPANY FEES FOR INSTALLATION. USE WELDED OR SCREWED PIPE AND FITTINGS PER PLUMBING SPECS. GAS COMPANY SHALL EXCAVATE, BACKFILL, AND REPAIR ANY PAVING OR SOD FOR GAS SERVICE LINE INSTALLATION FROM MAIN TO BUILDING. SUPPLIED WITH WATER METER ROUTE TO AIR GAP DRAIN 10 NOT USED 11 GAS SERVICE 12 NOT USED 131 WATER METER PLUMBING SCH EM NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE < " " PIPE MAY EXTEND J 3/4 BRONZE TYPICAL BALL VALVE: 3/4 BRONZE BODY SCREWED FLOOR GRATE TO BE BACKFLOW 3/4" BRONZE BODY, CONNECTION PRESSURE REDUC- AS WASTE OR VENT. I � COLUMN OR I j FASTENED DOWN WITH D DRAIN LINE PREVENTER FULL PORT, SCREWED ING VALVE SET AT 75 PSI. I PROVIDE CLEANOUT TEE I I n PARTITION Z L�1 W/ TEST PLUGS. CONNECTIONS. 1" WITH SCREWED COUNTER- I I AS SHOWN ® Cl_ SCREWS PRV I I ON FLOOR F=- INSTALL SO !T IS EASY TO TEST. SUNK ABS PLASTIC PLUG: I I Q r� BFP TAPERED-THREAD WITH PLAN. TFE JOINT COMPOUND. '� ® W MOUNT FLUSH I J Q IS CONCEALED IN A FACE SHALL WITH FINISHED 0 WHERE CLEANOUT TEE II CLEANOUT m FLOOR CHASE OR PARTITION, I BE WITHIN " " " P 3/4" x 1" PROVIDE A ROUND 18 I I 4 OF WALL *- AIR GAP = 2 X D (2 MIN.) INCREASER GAUGE STAINLESS STEEL I SURFACE. � o� COPPER COVER WITH BEVELED PROVIDE TUBE 1" 3/4" STRAINER: BRONZE BODY, PRESSURE EDGES AND FLATHEAD ; ; EXTENSION WATER SCREWED, STAINLESS STEEL SCREEN, GAUGE MACHINE SCREW. I Q I IF REQUIRED.SERVICE WITH SLOWDOWN PIPED TO FLR. DRN. ENTRY TO 6" 3/4" BRONZE STOP & WASTE VALVE, d a ' ABOVE SCREWED, RESILIENT SEATED, NRS. FLOOR EFD R FLOOR, DO NOT USE A QUARTER TURN VALVE. DRAIN HUB AT FLOORREFER TO WITH FLOOR E� FIXTURE SCHEDULE BG Q RISER LENC=TH SLEEVE " ®. a ® SLAB. AS REQUIRED FOR FURTHER WCO - AND INFORMATION. O I CAULK. 1" x 3/4" REDUCER. FLOOR SLAB LONG SWEEP AT END OF LINE Q_ OR COMBINATION WYE AND PROVIDE BACKFLOW PREVENTER OF TYPE AND MANUFACTURE APPROVED BY EIGHTH BEND IN ,I I I DIRECTION'`-HUB OUTLET LOCAL AUTHORITIES AND DEPARTMENT OF NATURAL RESOURCES. INSTALL RUN OF LINE. '�(NOTE: BACKFLOW PREVENTER IN HORIZONTAL UPRIGHT POSITION. SUPPORT ASSEMBLY I; � ��' OF FLOW SHEET FROM WALL BRACKET OR FLOOR STAND. PROVIDE REGULATOR ONLY IF PRES- A. FLOOR SINK COVER FLUSH WITH 11LE OR FLUSH SURE EXCEEDS 80 PSI - VERIFY. STRAINER AND REDUCING VALVE MAY BE PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WITH CONCRETE FLOOR IN AREA WITH NO TILE INSTALLED IN VERTICAL PIPE IF SPACE LIMITATIONS REQUIRE IT. CLEAN WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT: STRAINER BEFORE TURNING BUILDING OVER TO OWNER. PROVIDE ANY REQUIRED LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR. CERTIFICATION OF TEST OF BACKFLOW PREVENTER TO LOCAL AUTHORITIES. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. 14 FLOOR SINK DETAIL 15 DOMESTIC WATER SERVICE ENTRY 16 NOT USED 17 WALL CLEANOUT FILE :300331a D05076 NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE DATE:10/3/05 PROD. MGR. J.R. M.B. FLANNERY