Loading...
HomeMy WebLinkAbout0626 WEST MAIN STREET - Health (3) .r 6 TREADS @ 11" 16'-0" 26'-0" 13'-0" 13'-0" Ir 2448 ITI I 3'-91/2" � 13 14 r--------------i -- r-------------i r-------------1 r------------ 1 DN I I I I I I I I 5 4 . 1 I I I 1 I I STAIR 2 t I i II i CUTTING ROIOMI UP I II I SEAFOOd I n1 O U 10-5 x 6'-6" I DISPLAY LJ LJ L�I L L-1 Li ® 21 TD FD 2 FD FD 12 x 84 WOMEN I I i I o � � n N o � I L, I I IN OFDO 17FREEZER NCOOLER ; LOBSTER rj II RETAIL AREA u u O 3 F�]� FD E-5 FD® 23 10-5 x 6-5 E-1s 16'-7" n n FI n PACKING ROOM ILI --,I 21 I I MEN .I 1 II E-2o U U U FD STAIR 1 7'-0" p E_2 __ J 18 FFDLf 15 --- ------ 7'-0,, E-13 i — 5'-0" E-1s 5 -0" 1A 1 JANITOR SEAFOOD �I FFD L '� D ISPLAY; ;I i a — z — IAN LT 1 1 s 24 E-16 FD C FD C FD® FD® FD® FD® FD LOADING DOCK WORKING AREA Lu 22 2g48 17 FFD® LT 2 1 s i J LOADING PLATFORM r 1 -- OFFICE 1 ® ;' / COOLER 17 I o ;I FD ,2 FD I I EQUIPMENT SCHEDULE 2 17 cy ITEM SEE ANOTE GAS ELEC . op E-14 ^� N0. CITY CONNECTION 2460TY DESCRIPTION MFG AND MODEL REMARKS FURN INST KBTU/H D/C CORD/PLUG BY BY EACH E - M E-$ v I —ff�II ( 1 1 MOP SINK ADVANCE TABCD 9-OP-48 w/ K-246 UTILITY SHELF/MOP RACK GC GC OR EQUAL EXISTING E Q U I P M E I V I SCHEDULE — FS 91-01, IA 1 SERVICE FAUCET ADVANCE TABCD K-240 GC GC 2 3 HAND SINK OR EQUALWNE LHS-5 ITEM + SEE NOTE GAS ELEC I 10 GC GC N0. QTY DESCRIPTION MFG AND MODEL REMARKS A LOAD CONNECTION OR EQUAL * FURN INST KBTU/H D/C CORD/PLUG I i 3 1 STAINLESS STEEL WORK TABLE ADVANCE TABCD p p BY BY EACH E - M HDRC-307 E-1 I STAINLESS STEEL WORK TABLE EXIST 24' x 48' I 4 1 STAINLESS STEEL WORK TABLE ADVANCE TABCD p p O 0 L- i KSS-308 E-2 1 STAINLESS STEEL WORK TABLE EXIST 24' x 30' 0 0 11 5 1 STAINLESS STEEL WORK TABLE ADVANCE TABCO KSS-309 0 p 7 E-3 1 STAINLESS STEEL HOPPER EXIST — OFFICE 2 p O KITCHEN FD I _ 6 1 STAINLESS STEEL WORK TABLE ADVANCE TABCD p p I i KSS-246 E-4 1 STAINLESS STEEL WALL SHELF EXIST 102' x 16' p p 7 1 STAINLESS STEEL WORK TABLE ADVANCE TABOO p p _ FS I SS-368 E-5 1 PREP SINK (3 BAY) W/DRAIN BD EXIST 0 GC FD I 8 1 WALK-IN LOBSTER RM BRANCH RIVER PLASTICS; INC NON-REFRIGERATED 0 0 D E-9 E-7 13'x25' E E-6 1 POT SINK (3 BAY) EXIST 0 GC I i • I 9 LOT WALK-IN COOLER/FREEZER/CUTTING RM BRANCH RIVER PLASTICS, INC 0 0 D 21 55'x26' E E-7 1 STAINLESS STEEL WORK TABLE EXIST p p 16 I 10 1 RANGE/w OVEN GARLAND 0 0 236KBTU i G36-6R E-8 1 STAINLESS STEELWORK TABLE EXIST 0 0 11 2 STEAMER CLEVELAND RANGE 0 0 125KBTU D 8' LONG 24-CGA-10 EACH E E-9 1 STEAMER EXIST 0 0 125KBTU D 12 1 WALK-IN COOLER BRANCH RIVER PLASTICS, INC 0 0 D EACH E 9'xl2' E E-10 - SPARE - _ 13 1 MECHANDISER FREEZER-2 SECTION TURBO-AIR 0 O C NEMA 5-15P W/ GLASS ODORS TGF-49F M E-11 1 ICE BINS EXIST p p GENERAL � ��J I � � � IL NOTES C 14 1 MECHANDISER REFRIGERATOR-2 SECTION TURBO-AIR 0 0 C NEMA 5-15P I I W/ GLASS DOORS TGM-50RS M E-12 I ICE MAKER EXIST ICE DISCHARGE TO BE THROUGH 1HE CEILING, NEW CUSTOM S/S 0 GC D 15 LOT SNEEZE GUARD UNITED SHOW CASE CUSTOM p p CORNELIUS WCF-2200 CHUTE BY GC. GC VERIFY EQUIPMENT OPENING SIZES WITH OWNER, E 1, ALL NEW EQUIPMENT LISTED TO BE SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR OR OWNER, 16 1 EXHAUST HOOD (TYPE 1) CAPTIVE HIRE w/PSP REFER TO EXHAUST HOOD DWGS FOR ORDERING INFORMATION GC GC E-13 2 SEAFOOD DISPLAY EXIST 0 0 2. ALL EXISTING EQUIPMENT SPECIFIED, TO BE OWNER'S RESPONSIBILITY, 12'-0' x 4'-6' (INCLUDE FIRE SUPRESSION AND START UP) E-14 1 FOOD CUTTER EXIST -- 0 0 C NEMA 5-15P 3, ALL EXISTING EQUIPMENT SPECIFIED, TO BE REINSTALLED AT OWNER'S DIRECTION. 17 LOT WIRE SHELVING ADVANCE TABCD (OR EQUAL) p p1 ROBOT CIOUPE R 100 M 4, ALL FINAL UTILITY CONNECTIONS OF NEW AND USED EQUIPMENT BY GENERAL CONTRACTOR, (STAINLESS STEEL) - E-15 1 STAINLESS STEEL WALL SHELF EXIST p 0 5, THE GENERAL CONTRACTOR SHALL VERIFY ALL UTILITY REQUIREMENTS FOR ALL NEW AND EXISTING 18 2 STAINLESS STEEL WORK TABLE ADVANCE TABCD W/ EXTRA UNDER SHELF 0 o EQUIPMENT TO BE INSTALLED, KSS-308 E-16 LOT SCALE EXIST 0 0 C NEMA 5-15P 19 1 STAINLESS STEEL WORK TABLE ADVANCE TABCD W/ EXTRA UNDER SHELF 0 0 1 - IM 6, THE OWNER IS RESPONSIBLE FOR ALL FINAL EQUIPMENT MFR AND MODEL NUMBERS TO BE PURCHASED AND INSTALLED, KSS-309 E-17 LOT POS EXIST 20 1 MOBILE CART ADVANCE TABCD p p _ UC-3-2433 E-18 1 LOBSTER TANK (LT 1) EXIST O 0 21 1 POT/UTENSIL RACK ADVANCE TABCD 0 0 CUSTOM P D� S I G N E-19 1 LOBSTER TANK (LT 2) EXIST O 0 22 1 SHELL FISH TANK CUSTOM STAINLESS STEEL p p �I � "I CI--- A �S E R CD D CAPE FISH & LOBSTER w/DRAIN E-20 1 ICE FLAKER EXIST ICE DISCHARGE TO BE THROUGH THE CEILING. NEW CUSTOM S/S 0 GC D D A R T M O U T H , M ASS 02747 23 1 COUNTER BASE CUSTOM STAINLESS STEEL 0 0 HOWE CHUTE BY GC, GC VERIFY EQUIPMENT OPENING SIZES WITH OWNER, E 626 EAST MAIN STREET HYANNIS, MA E-21 LOT LOBSTER TANK (HOLDING) EXIST p p T E L_. S O 8 J J 3 — 3 8 24 1 COUNTER BASE CUSTOM STAINLESS STEEL p p EMAIL_; dcpdesign(g�com cost.net EQUIPMENT PLAN & SCHEDULE Sneer COMM. NO DRAWN BY: SCALE DATE K- C COPYRIGHT DCP DESIGNS 2004 DCP 1/4 '1- 0" 5/28/10 of VERIFY CONDENSATE WASTE TO FFD IT DN ----------- I I I I I I 1 it STAIR 2 CUTTING ROOM i UP ; ;I 10'-5" x 6'-6" s I N I II I 1 IND W TO FFD FD® FD® FD® FFD TD 12" x 84" 1/2" CW +16" �' 1/2" CW +16" WOMEN BIB) (HOSE BIB) i it i' 1/2" HW (140 ) +16" 1 OFD I I FREEZER COOLER E-5 (3)1-1/2" IND W. FS LOBSTERS EIH RETAIL AREA - Q I Q 1/2" HW (140 ) +16 O I I 9001 II FD® FS� „ FD® (3 Do ■ II 10-5 x 6 -5 PACKING ROOM --' ! ! MEN .I _ I I I - I II ! I FD® FFD iI E-13 IND W TO FFD STAIR 1 p� ICE FLAKER (SECOND FLOOR) VERIFY 1/2" FCW SUPPLY AND 1/2" HW (140 ) +33" ---- IND W TO FFD ON FIRST FLOOR 3" WASTE ------- 1/2" CW +33" JANITOR ! ! FFD ----------- ------- --------- Cl 1/2" CW+16" --{ 2 1-1/2" W. — — — — 1/2" CW +24"J 1/2" HW(1 10 )+16" (HOSE BIB) d — LT 1 z — 1/2" CW +16" �l (HOSE BIB) FD® FD® FD® FD C FD 0 FD® FD LOADING DOCK WORKING AREA FFD® LT 2 JE=PE-12 3/8" IND W TO FS ON FIRST FLOOR 1/2" FCW SUPPLY (SECOND FLOOR) LOADING PLATIFORM � — N C0 0. OFFICE 1 ® ; COOLER NO FD i FD I � NO �� VERIFY CONDENSATE WASTE TO FS 1/2" CW+16" 2 1/1/2" W. I (SPARE) 1/2" FCW SUPPLY (SECOND FLOOF 1/2" HW(110 )+16" L -1 EQUIPMENT PLUMBING LEGEND _ FS -1/2" CW +24" (HOSE BIB) 0- COLD WATER (C.W.) SO'__ N/A I I 0- FILTERED COLD WATER (F.C.W.) ate' N/A I I 1/2" HW (140 ) +16" 3/4" GAS-236 KBTU I I E_6 (3)1-1/2" IND W. ■- HOT WATER (H.W.) N/A (+30° EQUIP CONN) (MANIFOLD) TO FS TO GREASE INTERCEPTOR L- - -- 1/4" FCW (GENERATOR) 1/2" HW (140 ) +16" O DIRECT WASTE ---- - INDIRECT WASTE (INDIR.W.) 1/4" FCW (CONDENSER) ® FLOOR DRAIN (FD.) ■ GAS 3/4" GAS-144 KBTU I 1-1/2 IND W TO FT KITCHEN FD ® FLOOR DRAIN W/ FUNNEL (FFD) a N/A (VERIFY EQUIP CONN ® FLOOR SINK (FS.) +12" ABOVE FINISHED FLOOR OFFICE 2 ®FD FLOOR TROUGH (FT) P.C. PLUMBING CONTRACTOR 3/4" GAS-144 KBTU FS 1/4:: FCW (GENERATOR) (VERIFY EQUIP CONN 1/1/2'C NDCWNTONFT R) 1/4" FCW (GENERATOR) 3/4 GAS-144 KBTU 1/4 FCW (CONDENSER) (VERIFY EQUIP CONN 1-1/2 IND W TO FT GENERAL NOTES 1. REFER TO ARCHITECTURAL DOCUMENTS FOR FLOOR DRAIN LOCATIONS. 2. HEIGHTS SHOWN (+24") REFER TO HEIGHT OF STUB OUTS FROM WALLS. 3. PLUMBING CONTRACTOR RESPONSIBLE FOR ALL VALVES, TRAPS, TAILPIECES, FITTINGS, ETC NOT PROVIDED WITH EQUIPMENT. 4. PROVIDE SEPARATE SHUT-OFF VALVES AT EACH CONNECTION EVEN WHEN ALL HAVE A COMMON SUPPLY LINE. 5. IF A CONFLICT OCCURS BETWEEN A FLOOR DRAIN AND ANOTHER OBJECT, CONTACT THE KITCHEN DESIGN CONSULTANT TO ALTER FLOOR DRAIN LOCATION WITH RESPECT TO EQUIPMENT LOCATIONS. 6. ALL WORK AND MATERIALS TO CONFORM TO LOCAL & STATE BUILDING CODES. 7. CONSULT WITH OWNERS CHEMICAL VENDOR/REPRESENTATIVE TO VERIFY & COORDINATE REQUIREMENTS OF CLEANING CHEMICAL HOOKUPS & CONNECTION INSTALLATION FOR MOP SINK AND 3 COMPARTMENT WASH SINK. 8. PLUMBING CONTRACTOR TO VERIFY ALL NEW AND EXISTING EQUIPMENT PLUMBING REQUIRMENTS. D C P �E S IGN 9. COORDINATE THIS PLAN WITH ENGINEERS PLUMBING PLANS. I—I SE RO D CAPE FISH 8� LOBSTER C AA DARTMOUTH , MASS 02747 TE I—. ( SOS ) J 9 3 — 7 7 3 6 626 WEST MAIN STREET HYANNIS MA EMAIL_; dcpdesign©com cost.net PLUMBING CONNECTION PLAN sheet COMM. NO DRAWN BY: SCALE IDATE C COPYRIGHT DCP DESIGNS 2004 MCP 1/4"= V- 0" 1 5/28/10 t3 120V 1 P -/ H, 1 1 4HP-1 1 A +84" GENERAL CONTRACTOR TO VERIFY GENERAL CONTRACTOR TO VERIFY 14 120V/l PH, 1/2HP-10.9A +84" OELECTRICAL REQUIREMENTS FOR s ELECTRICAL REQUIREMENTS FOR COMPRESSOR AND CONDENSING UNIT COMPRESSOR AND CONDENSING UNIT WITH OWNER WITH OWNER F —7r L ITI I ------------ i WIP WP DIN r-------------i r- r-------------� i-------------� STAIR 2 I WP (SPARE) 1 ! L n n n n n n (SPARE) 1OV�1 PH +48" 120V/1 PH i JL J UP +48' i l Cl= WP 10-5 x 6 -6 L WPF-w-p" ! ! I I u u CUTTING ROOM I_J u i I O 00 + WOMEN WP 120-208V/1PH (CEILING DROP) J _ ! it FAN,LIGHTS,REFRIG CONTROLS, ! TIMER. � !•_ I W r J (SPARE) 120V/l PH +24" FREEZER COOLER i I I w I I RETAIL AREA O O I I I 0- Wp (SPARE) I-J 120V/1 PH (SPARE) 120V/1 PH n n O +48 WP (GANG BOX) +24" (SPARE) 120V/1 PH +48" WP Wp (SPARE) 120V/l PH +48" 10'-5" x 6'-5" 0 Wp J (SPARE) 120V/1 PH +24" II II n n n n PACKING ROOM LOBSTERS WP O MEN II — — I ! Li WP ! ! u u u I I ! !I ! ! 1120-208V/1 PH (CEILING DROP) p (SPARE) I I I STAIR 1 FAN,LIGHTS,REFRIG CONTROLS, I i 120V/1 PH TIMER. GC TO VERIFY WITH OWNER. u ! ! +48" ! J J (SPARE) 120V/l PH +48" u ! ! ------ WP WP II J J J JANITOR WP i i (SPARE) 120V/1 PH -- -- ------- i it (GANG BOX) +24 CONDENSING UNIT-230V/3pH POWER 120V/1 pH, LIGHTS (CEILING DROP) E-20 23OV/1 pH CONTROL WP 0 _ ICE FLAKER-230V/1 pH CONTROL 120-208V/1 PH (CEILING DROP) LT 1 _ FAN LIGHTS REFRIG CONTROLS ❑ SECOND FLOOR SEE NOTE #1 TIMER. GC TO VERIFY WITH OWNER. LOADING DOCK WORKING AREA (SPARE) 120V/1 PH +48" LT 2 WP WP _ 208V/1 pH, 25A CIRCUIT- 2HP COMPR. WPI J E-12 SECOND FLOOR LOCATION-SEE NOTE #1 i LOADING PLATFORM L - J i (SPARE) 120V/1 PH +48" 120-208V/1 PH (CEILING DROP) s FAN,LIGHTS,REFRIG CONTROLS, TIMER. GC TO VERIFY WITH OWNER. OFFICE 1 �; COOLER �) GENERAL CONTRACTOR TO VERIFY 12 ELECTRICAL REQUIREMENTS FOR --'' COMPRESSOR AND CONDENSING UNIT WITH OWNER ELECTRICAL_ ROUGH - I N PLAN I (SPARE) 208V/1 pH, 25A CIRCUIT- 2HP COMPR. (SPARE) 120V/1 PH +48' - _ I- SECOND FLOOR LOCATION-SEE NOTE #1 SCALE 1/4" = 1'-0" n I (SPARE) 120V/1 PH � (CEILING DROP) OFFICE 2 a .• I J KITCHEN WP 11 (3)120V/1PH, .3KW +66" J (SPARE) 120V/1 PH +48" GENERAL NOTES Ll WP EQUIPMENT ELECTRICAL LEGEND 1. ELECTRICAL CONTRACTOR MUST VERIFY ALL EXISTING AND OWNER SUPPLIED EQUIPMENT TO BE USED AND CONFIRM EXACT POWER REQUIREMENTS AND CORD/PLUG CONFIGURATIONS FOR PROPER ROUGH-IN CONNECTIONS. ALL NEW EQUIPMENT SHOULD BE O CONDUIT STUB-UP (SEE PLAN FOR SIZE) TREATED IN THE SAME MANNER. 2. ALL WORK AND MATERIALS TO CONFORM TO LOCAL & STATE CODES. d) 120V 1 PH. SINGLE RECEPTACLE 3. ALL RECEPTACLES AND JUNCTION BOXES TO BE FLUSH UNLESS NOTED. 4. ALL NOTATIONS (+24", ETC.) REFLECT HEIGHT OF RECEPTACLE OR J-BOX.. Ull 120V 1 PH. DUPLEX RECEPTACLE 6. EC VERIFY ALL LOCATIONS FOR COMPUTER TERMINALS, PHONE JACKS, P.Ol.S. (POINT PROOF�WP 120V 1 PH. DUPLEX RECEPTACLE WATER OF SALE) SYSTEMS INCLUDING PRINTER LOCATIONS, AUDIO/VIDEO, TV'S AND ALL OTHER ( ) SUPPORT EQUIPMENT WITH OWNER. p 120V 1 PH. QUAD RECEPTACLE (WATER PROOF GANG BOX) 7. COORDINATE THIS PLAN WITH ENGINEERS ELECTRICAL PLANS 120V 1 PH. ISOLATED GROUND DUPLEX RECEPTACLE ® 208/240V 1 PH. SINGLE RECEPTICLE Q JUNCTION BOX ❑� DISCONNECT SWITCH +12" A.F.F. - ABOVE FINISHED FLOOR E.C. ELECTRICAL CONTRACTOR C P IE:>E�I4C3rTT TELEPHONE JACK -1 -7 "1 C 1—I A S E FR O A D CAPE FISH 8c LOBSTER DARTMOUTH , MASS 02747 TE 1_. ( GOB) 9 9 3 — 7 7 3 6 626 WEST MAIN STREET HYANNIS, MA EMAIL_; dcpdesign<Dcom cost.net ELECTRICAL CONNECTION PLAN Sheet COMM. NO DRAWN BY: SCALE JDATE K- 3 C COPYRIGHT DCP DESIGNS 2004 DCP 1/4"= '1- 0" 1 5/28/10 of