Loading...
HomeMy WebLinkAboutDUNKIN DONUTS PLAN s ADDRESS REVIEWED FOR DESIGN CONFORMANCE ONLY ' APPROVAL ONDS HAS REVIEWED THEM OR CONFORMITY THESE BY THDK BRANDS DORMIOTY TO APPLICABLE PLANS S NOT EAT 1648 FAL M O U T H ROAD DUNK x CODES BRA ❑OR AREGULATIONS C E N T E RV I L L E , MA 02601 ❑ APPROVED AS NOTED: Submit Record Copy for Archives D ❑ DISAPPROVED AS NOTED: Revise and Resubmit ❑ INCOMPLETE INFORMATION: Add requested informaton and resubmit ' a Date: OWNER. o DUNKIN' BRANDS D O Construction Manager o A o SALVI COUTO ' . Notes: COUTO MANAGEMENT GROUP O o O 169 MAIN STREET w, STONE HAM , MA 02160 ABBREVIATION INDEX INDEX OF DRAWINGS ADA STATEMENT BUILDING DATA & AND GA. GAUGE Q.T. QUARRY TILE USE GROUP: A2 HEREBY CERTIFY THAT THE PLANS AND DRAWINGS FOR THIS © AT GALV. GALVINIZED QTY. QUANTITY T-1 TITLE SHEET/ ARCHITECTURAL DATA '"' D A/C AIR CONDITIONING GYP. BD. GYPSUM BOARD R.A. ALLIED DOMECQ PROJECT WERE DRAWN IN ACCORDANCE WITH ALL FEDERAL, TYPE OF CONSTRUCTION: TYPE V B T-1 .1 NOT USED STATE AND LOCAL LAWS, INCLUDING, BUT NOT LIMITED TO, THE A.D. AREA DRAIN HDWD. HARDWOOD RAD. RADIUS ,� STORIES: 1 � .- A.F.F. ABOVE FINISH FLOOR HDR. HEADER REF. REFRIGERATOR SP-1 NOT USED AMERICANS WITH DISABILITIES ACT (THE ADA ), THE ADA ; > K. ALUM. ALUMINUM H.M. HOLLOW METAL REINF. REINFORCING ACCESSIBILITY GUIDELINES AND ANY STATE OR LOCAL ALLOWABLE FLOOR AREA: 6000 S.F. ' ALT. ALTERNATE HORIZ. HORIZONTAL REV. REVISION SP-2 NOT USED ACCESSIBILITY CODES, REGULATIONS, OR STANDARDS ACTUAL FLOOR AREA: 1820 S.F. APPROX. APPROXIMATE HGT. HEIGHT REQ'D REQUIRED SP-3 NOT USED BD. BOARD I.D. INSIDE DIAMETER RESIL. RESILIANT DUNKIN' DONUTS ACTUAL FLOOR AREA: 1820 S.F. BLDG. BUILDING INSUL. INSULATION RM. ROOM SP-3.1 NOT USED Date: BM. BEAM INT. INTERIOR R.O. ROUGH OPENING ARCHITECT'S SIGNATURE HERE ' r BSMT. BASEMENT JT. JOINT SCHED. SCHEDULE SS-1 NOT USED BTWN. BETWEEN KIT. KITCHEN SEC. SECTION DUNKIN' DONUTS OCCUPANCY LOAD: .. BOT. BOTTOM LAM. LAMINATE S.F. SQUARE FOOT A-1 AS-BUILT FLOOR PLAN; DUNKINy BRANDS R E F E R E N C E S FIXED SEATS: 20 PERSONS C.L. CENTER LINE LAV. LAVATORY SHT. SHEET PROPOSED FLOOR PLAN; NOTES; DETAILS w C.T. CERAMIC TILE LT. LIGHT SIM. SIMILAR EMPLOYEES: 5 PERSONS CLG. CEILING MAS. MASONRY SPEC. SPECIFICATION A-2 REFLECTED CEILING PLAN, SCHEDULES, DETAILS CLOS. CLOSET MAX. MAXIMUM SQ. SQUARE A-2.1 NOT USED DUNKIN BRANDS SPECIFICATION BOOK (REV. 08/05/14) TOTAL OCCUPANCY: 25 PERSONS F4a CM CONSTRUCTION MGR. MECH. MECHANICAL S.S. STAINLESS STEEL CMU CONC. MASONRY UNII MTL. METAL STD. STANDARD A-3 NOT USED NATIONAL ACCOUNT SOURCE (REV. 03/17/15) _ COL. COLUMN MFR. MANUFACTURER STL. STEEL INFORMATION BOOKLET FLAME SPREAD: CONC. CONCRETE MIN. MINIMUM STRUCT. STRUCTURAL A-4 NOT USED DUNKIN' BRANDS EQUIPMENT (ISSUED 2014) FREEZER CORE MATERIAL: 25 - CONT. CONTINUOUS MISC. MISCELLANEOUS SUSP. SUSPENDED , A-5 NOT USED SPECIFICATION BINDER CONST. CONSTRUCTION M.O. MASONRY OPENING TEL. TELEPHONE FREEZER METAL PANEL: 25 DEPT. DEPARTMENT MTD. MOUNTED THK. THICK A-5ALT NOT USED 1999 FDA FOOD CODE (ISSUED 2013) DTL. DETAIL N.I.C. NOT IN CONTRACT THRU THROUGH SMOKE DEVELOPMENT RATINGS: � i x D.F. DRINKING FOUNTAIN NO. NUMBER T.O.P. TOP OF PLATE A-6.1 NOT USED DIA. DIAMETER NOM. NOMINAL T.O.S. TOP OF STEEL FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS FOR INTERIOR WALL AND FREEZER CORE MATERIAL: 250 � ; DIM. DIMENSION N.T.S. NOT TO SCALE T.O.SL TOP OF SLAB A-7 NOT USED CEILING FINISH MATERIALS, (INTERIOR FINISH CLASSIFICATION: III/ 76-200): FREEZER METAL PANEL. OVER 500 DISP. DISPENSER O.A. OVERALL TRT. TREATED A-8 NOT USED MATERIAL FLAME SPREAD SMOKE ; w.. DN. DOWN O.C. ON CENTER TYP. TYPICAL RATING DEVELOPMENT DR. DOOR O.D. OUTSIDE DIAMETER V.C.B. VINYL COMPOSITION BASE A-9 NOT USED BASED ON THE FOLLOWING CODES D.S. DOWN SPOUT OPNG. OPENING V.C.T. VINYL COMPOSITION TILE FIBERGLASS REINFORCED PANELS 175 135 INTERNATIONAL BUILDING CODE, 2009 EDITION, WITH AMENDMENTS A-10 INTERIOR ELEVATIONS; KEY PLAN; --- DWG. DRAWING OPT. OPTIONAL VERT. VERTICAL VINYL WALL COVERING 5 5 INTERNATIONAL PLUMBING CODE, 2009 EDITION, WITH AMENDMENTS -VERIFY IN FIELD INTERNATIONAL MECHANICAL CODE, 2009 EDITION, WITH AMENDMENTS EA. EACH PL. PLATE V.I.F.v. DETAILS; SCHEDULES PLASTIC LAMINATE 30 200 INTERNATIONAL ENERGY CONSERVATION CODE, 2009 EDITION, WITH AMENDMENTS w EL ELEVATION P.LAM. PLASTIC LAMINATE V.W.C. VINYL WALL COVERING ENAMEL PAINT ON TRIM, DOOR 5 ~ `n ELEC. ELECTRICAL PLUMB. PLUMBING W/ WITH A-11 NOT USED INTERNATIONAL RESIDENTIAL CODE, 2009 EDITION, WITH AMENDMENTS (NOTE: a FRAMES, WOOD SHELVING THE REQUIREMENTS FOR AUTOMATIC SPRINKLER SYSTEMS IN ONE— AND r� EQ. EQUAL PLYWD. PLYWOOD W.C. WATER CLOSET o EQUIP. EQUIPMENT PR. PAIR wD. wooD A-12 MISCELLANEOUS DETAILS WOOD STAIN NATURAL WOOD SURFACES 5 TWO—FAMILY DWELLINGS AND TOWNHOUSES WILL NOT TAKE AFFECT UNTIL APRIL CLEAR SEALER NATURAL WOOD DOORS 5 1, 2012 UNLESS REQUIRED BY LOCAL ORDINANCE) z Un 1! EXIST. EXISTING PROP. PROPERTY W/o WITHOUT K-1 EQUIPMENT PLAN NATIONAL ELECTRICAL CODE, 2008 EDITION, WITH AMENDMENT O m -' I EXT. EXTERIOR P.S.F. PER SQUARE FOOT wP. WATERPROOFING ACCOUSTICAL CEILING TILES 23 _ ___� F.D. FLOOR DRAIN P.S.I. PER SQUARE INCH WT. WEIGHT K-2 EQUIPMENT SCHEDULE z FIN. FINISH PTD. PAINTED WWM. WELDED WIRE MESH W � LJ i FL. FLOOR -3 EQUIPMENT SCHEDULErL P P.V.C.VC POLY VINYL CHLORIDE F.O. FACE OF K-4 EQUIPMENT SCHEDULE FT. FOOT DUNKIN BRANDS DATA FURN. FURNITURE E-1 ELECTRIC LIGHTING PLAN; SCHEDULE; NOTES � i E-2 ELECTRIC POWER PLAN; ELECTRIC 1 -LINE SEATING: o DIAGRAM; NOTES STORE DIMENSIONS: SQ. FOOTAGE # OF TABLES , P-1 PLUMBING PLAN; SCHEDULES; NOTES RETAIL SERVICE AREA 778 SQ. FT. # OF BARRIER FREE SEATING UNITS 2 P-2 PLUMBING PLAN; SCHEDULES; NOTES SEATING AREA 214 SQ. FT. # OF SEATS AT TABLES (INCLUDES HCP) 20 P-3 NOT USED PREP AREA 471 SQ. FT.GRAPHIC SYMBOLS P-4 3M WATER FILTRATION SYSTEM DETAILS TOTAL # OF SEATS 20 � - OFFICE AREA 45 SQ. FT. NOTE: SOME SEATING IS COMMON. SEE PLANS FOR THIS -J LIL -..__ SECTION NUMBER FINISH NUMBER TOILETS 86 SQ. FT. STORE FROM BUILDING ARCHITECT. ONLY DUNKIN' DONUTS - Al SEATING LISTED ON THIS SHEET. 202 SHEET NUMBER P-21 WALK-IN FREEZER/COOLER 23 SQ. FT. �-l-� SECTION FINISHES OTHER (HALL, UTIL) 203 SQ. FT. o = J )i H1 DETAIL NUMBER TOTAL: 1820 SQ. FT. DETAIL 301 IMAGE TYPE: o - u SHEET NUMBER REST ROOMS: DETAIL NUMBER �-- SINGLE BRAND DID 1a NUMBER OF RESTROOMS 2 PARTITION KEY DOOR MARK PUBLIC ACCESS TO REST ROOMS Y SIGNAGE: W �� U HANDICAP ACCESSIBLE Y NOTE: ALL SIGNAGE TO BE DUNKIN' DONUTS LATEST DESIGN ;, DOOR PARTITION TYPES AND SUBJECT TO APPROVAL BY TOWN AND LANDLORD. B DRIVE-THRU: SIGNAGE FILED UNDER SEPARATE PERMIT BY DUNKIN' D100 DONUTS SIGN MANUFACTURER. EQUIPMENT TAG COLUMN REFERENCE GRIDS YES/No NO -' NUMBER OF DRIVE THRU WINDOWS OOR MENU BOARD SIZE (SINGLE, COMBO) CAR LENGTHS FROM MENU TO WINDOW DRAWING NOTES INTERIOR ELEVATION INDICATOR E STACKING .(TOTAL # OF VEHICLES) WALK IN FREEZER/ COOLER: JOB#: D16C0 ESCAPE LANE REMOTE COMPRESSORS REQUIRED DATE: 03 j DRIVE THRU TIMER SYSTEM DISTANCE FROM COMPRESSOR TO BOX PC#: 32`102 C.M. V. n u i --------------------—-- t 2 2 2 2 2 2 HAND REF. 5 SINK HAND , SINK ` KITCHEN ' NOTE: ~' / F'EE AND FIELD TEAM TO DETERMINE IF EXISTING BACK 2 / ROOM EQUIPMENT AND COLD/DRY STORAGE CAPACITIES CONFORM TO CURRENT STANDARDS. a ;CB PREP I II II 1 2 ,� - -� �_��__��_� � AREA KIT. 8'-0" FINISHING K HALL FFI CE I T• N (EXISTING) � EXIST. � HALL 0 FFI C E � �..._:�:�._...... �__ :. .. /FILLER EXIST. ILLE �Q— (EXISTING) COL_" OL I 0 � %I% 0 ° $ r-r-r1 I rT_ -,O Low (EXISTING) v�C/� 0 O �P HEIGHT ° ( B KE Y I BJA E Y I �.. WATE S - ICB STA. A I S N O 0 -------- PUMPS V oo `----------- -......y��yy--------- ---------------- ' ------------- -� LVI-- �„ L 1 �6 10 SERVING AREA ��-��� ��a,rWinter ogee �SEE NOTE#4 NEW �/ ��ry'� G,�C 46"Bev. Needs 172"L and 26"H c° r •1 H.W. �p1 5'-8" FILLER 6'-0" COFFEE S'-4" POS 4'-6" COFFEE ( �� '� COFFEE STATION POS STATION �— — R---- --------¶-------------- ——————————— K TOILET -- � u li I� ,� �� iI I� ti vo 0 0� u EXISTING ° SERVING , RESTROOM �, O o VON- AREA COUNTERS TO BE REMOVED, TYP O� �� VDU _ 'd _j - ` ' 3'-0,. /�� // EXISTING J ti TOILET _ GATE RESTROOM -- �`= C4, , - // RETAIL m 4 MERCHANDISER ,a n �I ? 91 �I L t SERVE ��? zo I COOLER D' % m 28 z .Y ------------- 6 ];`�U, .<� I _4s! ADJOINING -4 SALES AREA ADJOINING �`�9 ?� SALESco � a TENANT (20 SEATS) �� ' T e AREA TENANT �ppTti G=� TRAS Q„ SPACE © � SPACE ; �* Lij [(I jS� 92 EXISTING O VESTIBULE EXISTING 4s" BLE VESTIBULE V) -- Z > cn 9261179'218 ® Z Ld I•,J F= � FK J Q VESTIBULE LEGEND: o z (EXISTING) EXISTING STUD WALL, 2x4 OR 2x6 STUD z _1 WALL ® 16" O.C. AS- BUILT FLOOR PLAN NEW STUD WALL, PROPOSED FLOOR PLAN 2x4 OR 2x6 STUD SCALE: 1/4" = V-0" WALL ® 16" O.C. SCALE: 1/4" = V-0" Vh x a'• 3 GENERAL NOTES 10. TOILETS: W - a. LAVATORY TO HAVE LEVER HANDLES, SPRING FAUCETS OR SELF METERING FAUCETS. 4. 2"x4" ELECTRICAL BOX 6'-0" A.F.F. WITH 1" CONDUIT IN WALL TO ABOVE ROOF DECK 1 A. GENERAL CONTRACTOR SHALL REFER NE WRITTEN SPECIFICATIONS FOR CONTINUE EVERY 3RD ROOF DECK CONTINUE EVERY 3RD ' ADDITIONAL INFORMATION NOT CONTAINED IN THE DRAWINGS. b• A COAT HOOK 54" ABOVE THE FLOOR WILL BE MOUNTED ON THE CEILING. CENTER 32"x32"x3/4" PLYWOOD BLOCKING IN WALL FOR VDU UNIT. MEMBER E ROOF DECK MEMBER TO ROOF DECK ri U B. GENERAL CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING AT SHELVING, 3 BACK SIDE OF THE HANDICAP STALL DOOR. NOTE THAT THE MAXIMUM CONNECTION LENGTH BETWEEN A VDU(S) AND ITS TYP) (TYP.) I ':.✓. COMPARTMENT SINK, T & S SPRAY BRACKET, POT RACK, HAND SINKS, MOP c• LOCATE THE WATER CLOSET 18" FROM THE CENTER LINE OF THE DEDICATED CPU IS 75'-0" AND ONE TELEPHONE JACK IN OFFICE TO BE AN TABLE TOP SUSPENDED CEILING (TY PLYWOOD 0 - SINK, FAUCETS, TIME CLOCK, GRAB BARS, LAVATORIES, HAND DRYERS, MIRRORS, FIXTURE TO THE WALL. THE SEAT WILL BE 17" TO 19" ABOVE THE ISDN LINE. NQTIFY DUNKIN' DONUTS IF NOT REGIONALLY AVAILABLE. 4 0 G OR Z ! _. PAPER TOWEL DISPENSERS, SOAP DISPENSERS, OTHER ACCESSORIES, ETC. FLOOR TO THE TOP OF SEAT. 5. (OPTIONAL) 2'x4" ELECTRICAL BOX IN FRONT LINE CHASE WITH 1 CONDUIT 1/2"GYPSUM BD.ON SUSPENDED CEILING OR 0_ ---� C. REFER TO THE 'K' DRAWING(S) FOR INFORMATION REGARDING THE EQUIPMENT d PROVIDE TWO 42" LONG x 1 1/2" OUTSIDE DIAMETER PENNED GRAB OVER TO HUB AT MAIN CASH STATION. THIS IS FOR COUNTER MOUNTED METAL SUSPENSION 1/2"GYPSUM BD.ON VDU UNIT AT COFFEE STATION. I X W SYSTEM SEE PLAN FOR METAL SUSPENSION `t J° ' AND EQUIPMENT LAYOUT. BARS, 1 1/2" FROM THE WALL WITH ONE BEHIND AT 6" FROM THE w M. NOTE: "P.O.S. ALL POWER OUTLETS FOR P.O.S. DEVICES ARE DEDICATED U - " O 3 --� y D. GENERAL CONTRACTOR SHALL INSTALL 2"x8" BLOCKING FOR SANDWICH STATION, WALL AND ONE ADJACENT TO AT 12" FROM THE WALL 33"-36" I p Z Q w Z LOCATION. SYSTEM SEE PLAN FOR O 0" M TOP OF BLOCKING ® 4'-4" A.F.F. ALSO BLOCKING FOR VDU MONITORS. PARALLEL TO AND ABOVE THE FLOOR. WHEN A TANK PREVENTS CIRCUITS WITH THIRD WIRE ISOLATED GROUND. AN IG IS AN INSULATED WIRE, - z z LOCATION. 0 ( — E. ALL TOILET WALLS AND OFFICE WALLS TO HAVE ALUMINUM FACED FIBERGLASS THIS LOCATION OF REAR GRAB BAR INSTALL GRAB BAR 3" ABOVE SEPARATED FROM ALL OTHER GROUND WIRES, RUNNING BACK TO THE BUILDING N � [1��CLR. Y 4"WOOD OR METAL d INSULATION. THE TANK. MAIN OR COMPLEX POWER PANEL. NEMA STANDARD L5-15R I.G. FOR , � - Q STUDS @ 16"O.C. 4"WOOD OR METAL m F. SEE SITE PLAN PROVIDED BY OWNER FOR NUMBER AND LOCATION OF THE e• LAVATORY TO BE MOUNTED 32" ABOVE THE FINISHED FLOOR TO RIM RECEPTACLE AND PLUG. USE OF IG DUPLEX OR QUADPLEX OUTLETS: (I.E., 2 —g cV "� N J STUDS @ 16"O.C. O L—J ` FOLLOWING SITE FURNISHINGS (ALL BY WAUSAU TILE): TABLE WITH SEATING WITH KNEE SPACE OF 30" IN WIDTH AND 27" IN CLEAR HEIGHT. HUBBELL IG-5262, IG-5362 OR EQUIVALENT). c� 3-1/2"R-13 SOUND BATT 3-1/2"R-13 SOUND BAIT mac+ I s .._ #TF313BD3, ADA TABLE WITH SEATING #TF3139D3, TRASH CAN NEXT TO INSULATION @ RESTROOM — , f• INSTALL MIRROR 36" ABOVE THE FINISHED FLOOR (TO BOTTOM) AND N. GC. SHALL NOT PROCEED WITH CONSTRUCTION UNTIL V.D.U. LOCATIONS ARE PLAN E L E VA TI 0 N WALLS INSULATION @ RESTROOM { E EXTERIOR SEATING AREA #TF1020A5, TRASH CAN WITH CHUTE NEXT TO 72" TO TOP. DETERMINED. WALLS e'- DRIVE—THRU AREA #TFl02lA5, GROUNDSKEEPER SMOKING MANAGEMENT 9• DISPENSERS TO BE MOUNTED A MAXIMUM OF 42" ABOVE THE FLOOR 0. COORDINATE UTILITY LOCATIONS NECESSARY FOR OPTIONAL TRAINING MODULE. FIXED ACCESSIBLE TABLE TYPICAL SUBSTRATES FOR TYPICAL SUBSTRATES FOR ! 41 RECEPTACLE, COLOR: BEIGE, #2570-88. (OPTIONAL) TO ALL OPERATING OR DISPENSING SLOTS. P. STANDARD HOT WATER HEATER IS TANKLESS HOT WATER HEATER BY RINNAI. INTERIOR WALL;SEE NOTE INTERIOR WALL;SEE NOTE G. PROVIDE FIRE EXTINGUISHERS, TYPE ABC, WALL HUNG, TOP ® 5'-0" A.F.F. (BY h• TOILET PAPER DISPENSERS MOUNTED 19" TO CENTER LINE ABOVE COORDINATE EXACT SIZE W/ LOCAL REQUIREMENTS. ROTATE SO FLAME IS NOT TO SCALE BELOW SERVICE BELOW THE FLOOR. OPPOSITE MOP SINK. PROVIDE DIRECT LINE W/ TEMPERATURE REGULATOR VALVE AREA KITCHEN IF A A NUMBER AND LOCATION AS DETERMINED BY LOCAL CODE. 11. ACCESSIBLE PARKING SPACES, PASSENGER LOADING ZONES, RAMPS, AND TO HAND WASHING SINKS. OPTIONAL TO BE STANDARD TANK UNIT — THE SIDE SIDE H. IF A LARGER OFFICE IS REQUIRED, EXPAND TOWARD BOH, NOT FOH. I- BEVERAGE REFRIGERATOR TO BE 54" HIGH WHEN NOT PLACED AGAINST WALL. SIGNAGE SHALL COMPLY WITH THE (ADA). SELF—VENTING TYPE. IF USED, RUN VENT TO OUTSIDE WALL. FLOOR FLOOR; J. HANDICAP REQUIREMENTS: 12. ON TOILET DOOR(S), SIGNAGE IS REQUIRED WITH RAISED LETTERS AND IN Q. PROVIDE WATER FILTRATION SYSTEM (BRANCH OFF MAIN LINE) FOR COFFEE „ „ i THE GENERAL CONTRACTOR WILL ACQUAINT HIMSELF WITH THE HANDICAP BRAILLE INDICATING "MEN" OR "WOMEN". MOUNT 5' CENTER AFF OPENING BREWING EQUIPMENT, ICE MACHINES, POST MIX. LOCATE AS SHOWN. TYPE B TYPE "D" - REQUIREMENTS OF THE APPLICABLE STATE AND THE AMERICAN DISABILITIES ACT SIDE OF DOOR. SIMILAR SIGNAGE REQUIRED IF BUTTONS PROVIDED. R. PLANS CALL FOR FIBERGLASS INSULATION IN WALLS. IT CAN BE KRAFT FACED. 7' MAX. SPACING (ADA) AND INSURE THAT THIS FACILITY WILL BE ACCESSIBLE. THE FOLLOWING IS K. FURNISH ALL LABOR AND MATERIAL NECESSARY FOR THE COMPLETE EXPOSED KRAFT FACED INSULATION TO BE FIRERATED TYPE, OR REGULAR INSTALLATION OF CEMENT BOARD BACKING FOR F.R.P. AND CERAMIC TILE. KRAFT FACED INSULATION TO HAVE MINIMUM OF 1/2" GYPSUM OVER. IF CEILING, I- -I ALL JUNCTIONS BETWEEN THE WALL SURFACES AND THE EDGES OF ATTACHED EQUIPMENT AS WELL AS ALL ANNULAR A PARTIAL LIST OF REQUIREMENTS: OPENINGS AROUND PIPES DUCTS OR OTHER CONDUITS WERE THEY PASS THROUGH WALLS AND FLOOR SHALL BE SEALED 1• AISLES MINIMUM 36" WIDE. TYPICAL SUBSTRATES FOR INTERIOR WALLS SHALL BE AS FOLLOWS: USE 5/8" TYPE 'X' GYPSUM. WITH A MIXTURE OF STEEL WOOL AND APPROVED CAULK/SEALING COMPOUND, 2. CURB CUTS PROVIDED AT HANDICAP PARKING SPACES. 1• PREP AREA AND STORAGE AREAS: 0'-0" TO S-0": 5/8" DUROCK CEMENT S. G.C. WILL BE RESPONSIBLE TO INSTALL ALL INTERIOR GRAPHIC ELEMENTS • ENSURE TOP PLATES AND THE JOINTS BETWEEN WALLS AND CEILINGS ARE SEALED. - - --- "3. MAX. SLOPE OF 5% OR 1:20 IN ALL PARKING LOTS AND ON SIDEWALKS, ALL BOARD, 3'-0" & ABOVE: 5/8" PLYWOOD. SUPPLIED BY THE MILLWORK SUPPLIER. • DUCT SHAFT&PIPING PENETRATIONS:OPENINGS FROM CRAWL SPACE AND ATTIC ARE SEALED. OTHER AREAS WITH GREATER SLOPE WILL BE CONSIDERED A RAMP. 2• SERVICE AREA: 5/8" MIN. PLYWOOD T. G.C. TO PROVIDE BRUSHED ALUMINUM CORNER GUARDS WITH 2" LEGS TO ALL � X ALL SHAFTS.PROPER FLASHING AROUND FLUE AND GAPS SEALED AND CAULKED S {E E 4• SIDEWALKS WILL BE A MINIMUM OF 4'-0" WIDE, WITH A 5'x5' PAD IN FRONT 3• SALES AND SEATING AREAS: MIN. 5/8" GYPSUM BOARD. SALES AREA OUTSIDE CORNERS. i� Q • ALL PENETRATIONS AT EXTERIOR WALLS ARE SEALED INCLUDING VENTS,AND ELECTRICAL CONDUIT&BOXES. OF EXTERIOR OUTSWINGING DOORS PER CODE. L. GENERAL CONTRACTOR TO PROVIDE FOR P.O.S SYSTEM AS SHOWN ON U. BRONZE COLOR MYLAR ROLL DOWN SHADES ARE OPTIONAL AT GLAZING. N g PROVIDE CORROSION-PROOF RODENT/BIRD SCREENS(E.G., STEEL MESH)FOR ALL BUILDING OPENINGS THAT ' s ELECTRICAL DRAWINGS OR, AT A MINIMUM THE FOLLOWING CONDUITS; V. TABLES ARE TO BE FREE STANDING EXCEPT FOR ADA TABLES, AND OTHERS CANNOT BE FULLY SEALED AND CAULKED(E.G.,VENTILATION SYSTEM INTAKE/EXHAUST OUTLETS AND ATTIC VENT 5• RAMPS HAVE TO HAVE A MAXIMUM SLOPE OF 1:12 WITH HANDRAILS AT 34" NOTED AS TO BE BOLTED TO THE FLOOR. OPENINGS). r, AND 19" ABOVE THE FLOOR ON BOTH SIDES AND TO EXTEND BEYOND THE 1• 2 1/2" I.D. FROM 4x4x3 JUNCTION BOX LOCATED BEHIND OFFICE DESK UP QUEUE RAIL DETAIL - , ti', „M..•:,., TOP AND BOTTOM OF THE RAMP A MINIMUM OF V-6". WALL TO ABOVE CEILING. W. DIMENSIONS SHOWN ARE TO THE FACE OF FINISH. 6• ALL DOORS WILL HAVE A MINIMUM OF 1'-6" CLEAR ON THE LATCH (PULL) TYPICAL SUBSTRATES FOR INTERIOR WALLS SHALL BE AS FOLLOWS: 2. FROM A HUB IN THE FRONT LINE CHASE UNDER SLAB TO WALL BEHIND X. THESE PLANS ARE BASED ON MINIMUM DUNKIN BRANDS CORPORATE DESIGN KITCHEN AND STORAGE AREAS:INTERIOR W LLS- H LL BE AS CEMENT BOARD, SIDE OF THE DOOR. (EXCEPT IN CERTAIN STATES WHERE IT WILL BE DISPLAY RACKS PROVIDE THREE (3) 2" CONDUITS WITH 2'-0" SWEEPS AT REQUIREMENTS. THE STRUCTURAL DESIGN, FOOTING DESIGN, ADA COMPLIANCE ENDS. TERMINATE ABOVE THE CEILING. (UNDER FLOOR IF BASEMENT). V-o"AND ABOVE-%"PLYWOOD. AND GENERAL BUILDING REQUIREMENTS HAVE BEEN EVALUATED TO MEET ALL NOTE: a ----- 2'—O") ADA STATE AND LOCAL CODES. SERVICE AREA:/"MIN.PLYWOOD w 7• DOOR MATS AND THRESHOLDS TO BE A MAXIMUM OF 1/2" HIGH. 3• 1" I.D. CONDUIT FROM BEHIND THE DRIVE THRU CASH STATION UP WALL TO MAXIMUM DISTANCE APART FOR A SALES AND SEATING AREAS:%"GYPSUM BOARD JOB#, : DI 6004 8• DOOR HARDWARE SHALL BE MOUNTED BETWEEN 36" AND 42" ABOVE THE ABOVE CEILING, USE 2'-0' SWEEPS AT BOTTOM TO SIDE NEAREST FRAME TWO POST QUEING RAIL INSTALLATION GENERAL CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING IN BATHROOMS FOR GRAB BARS,LAVATORIES,HAND - - _._...._.. FLOOR. WALL IF WINDOW BEHIND PROVIDING CHASE AS REQUIRED SO NO WIRING SHALL BE 7'-0" DRYERS,MIRRORS,PAPER TOWEL DISPENSERS,SOAP DISPENSERS,AND OTHER ACCESSORIES AS REQUIRED UNLESS DATE: 03/15/1 " 9. DOORS TO HAZARDOUS AREAS TO HAVE KNURLED HANDLES. BENDS LESS THAN 2'-0" RADIUS. OTHERWISE NOTED. PC#: 33036�! FIRE ALARM SYSTEMS CONVENIENCE POWER NOTES THE FOLLOWING ARE GENERAL APPLICATIONS FOR FIRE SYSTEMS. CONTRACTOR NOTE: CONVENIENCE POWER IS NOT PROVIDED ON THIS PLAN. LOCATIONS FOR CONVENIENCE POWER TO BE REVIEWED IS TO VERIFY SYSTEMS COMPLY W/ ALL STATE AND LOCAL CODES BEFORE INSTALLATION/ RELOCATION. W/ FRANCHISEE. TYPICAL LOCATIONS FOR ADDITIONAL OUTLETS: FRONT AND BACK LINE COUNTERS, OFFICE, ... PREP AREA ABOVE CEILING IN SALES AREA AND VESTIBULE, ROOF FOR HOLIDAY LIGHTING. „v;ew (EXISTING) FA FIRE WARNING SYSTEM (HORNS AND STROBE LIGHTS) TO BE INSTALLED IN ENERGY EFFICIENCY GUIDELINES y O ACCORDANCE WITH ALL STATE AND LOCAL CODES 1. RELAMP & REBALAST FIXTURES INTERIOR: FROM T12 TO SUPER T8 FLUORESCENT LAMPS W; ALL EXISTING LIGHTS IN THE BACK OF STORE TO S SMOKE DETECTOR W/ BATTERY POWER BACK-UP, MOUNT AS REQUIRED. EXTERIOR: FROM EXISTING TO APPROPRIATE WATTAGE PULSE START METAL HALIDE LAMPS & FIXTURES - SEE BE REPLACED WITH LED LIGHT FIXTURES. REPAIR DBI'S SITE LIGHTING CRITERIA FOR MORE INFORMATION AND REPLACE CEILING TILES AS REQUIRED HD HEAT DETECTOR W/ BATTERY POWER BACK-UP, MOUNT AS REQUIRED. 2. INSTALL OCCUPANCY SENSOR CONTROLS IN BATHROOMS, OFFICES & STORAGE CLOSETS 3. REPLACE ANALOG HVAC THERMOSTATS W/ PROGRAMMABLE THERMOSTATS 4. INSTALL TIME CLOCKS W/ INTERRUPTIBLE CONTACTORS ON OLDER MODEL BAGEL OVENS © ELECTRICAL PANEL 1 _ , 5. REPLACE EXISTING WALK-IN COOLER & FREEZER MOTORS W/ ELECTRONICALLY COMMUTATED MOTORSa 6. IMPLEMENT A WEB-BASED ENERGY MANAGEMENT SYSTEM j SEE P.O.S. P.O.S. SYSTEM NOTES NOTE: SEE DBI'S "ENERGY EFFICIENT & FUTURE FRIENDLY STEPS TO SAVE" PAMPHLET FOR MORE INFO. NOT ALL A17 NOTE B GUIDELINES MAY APPLY TO EVERY STORE - CONSULT CONSTRUCTION MANAGER / OWNER KIT. GENERAL CONTRACTOR TO PROVIDE FOR P.O.S. SYSTEM AS SHOWN ON ELECTRICAL HALL 0 F F I C E A3 8 DRAWINGS OR, AT MINIMUM THE FOLLOWING CONDUITS: ELECTRICAL NOTES ' (EXISTING) LED-6 A 2 1 2" I.D. FROM 4x4x3 JUNCTION BOX LOCATED BEHIND OFFICE DESK UP THE (EXISTING) c -;'...`4 :� °',< }:• :::`. WALL TO ABOVE CEILING. 1. PANEL BOARDS ARE PROVIDED FOR CHECKING TOTAL SERVICE REQUIREMENTS E.C. SHALL USE l J 6'-10" JUDGMENT IN REVISING CERTAIN CIRCUIT'S AND ARRANGING EQUIPMENT ON PANEL BOARDS IN THE TO EXIST B) FROM A HUB IN THE FRONT LINE CHASE UNDER SLAB TO WALL BEHIND DISPLAY MOST ECONOMICAL MANNER. E.C. SHALL DETERMINE FINAL SERVICE LOAD REQUIREMENT FROM LOADS UDIO SYSTE . ... RACKS PROVIDE THREE (3) 2" CONDUITS WITH 2'-0" SWEEPS AT ENDS. TERMINATE GIVEN IN PANELBOARDS AND PROVIDE SERVICE ACCORDINGLY. o "•• '• ' ' '• ''•"' � ' ABOVE CEILING. (UNDER FLOOR IF BASEMENT). TILE START 2. INSTALL ALL ELECTRICAL OUTLET BOXES HORIZONTAL AND FLUSH IN WALLS WHERE POSSIBLE. PROVIDE a O SOFFIT LINE (D--IN SOFFIT O POINT C) NOT USED APPROPRIATE FLUSH MOUNTING RECEPTACLE BOXES AND CONDUIT AS REQUIRED FOR MOUNTING OF OUTLETS ON R Z CONCRETE WALLS. w to '� A2 D) 2"x4" ELECTRICAL BOX 6'-0" A.F.F. WITH 1" CONDUIT IN WALL TO ABOVE 3. NOT USED CEILING. CENTER 32"x32"0/4" PLYWOOD BLOCKING IN WALL FOR VDU UNIT. SEE P. �� 4. SEE "TECHNICAL REQUIREMENTS FOR THE COMTREX SYSTEMS CORPORATION DUNKIN' DONUTS P.O.S. SYSTEM" P A 1 A A THE MAXIMUM CONNECTION LENGTH BETWEEN A VDU AND ITS DEDICATED CPU IN FOR ALL INFORMATION RELATING TO CASH REGISTER WIRING. (FURNISHED BY DUNKIN' DONUTS.) TOILET NOTE " i THE FRONT LINE CHASE IS 75-0'. THE CONNECTION THEN GOES TO THE OFFICE. y; 3�� HD D 4 L D 4 D 4 SERVING 5. PROVIDE CORD WITH GROUND AND CAP FOR EACH COFFEE MAKER AND CARBONATOR. G.C. TO PROVIDE ONE ISDN TELEPHONE JACK IN THE OFFICE. NOTIFY DUNKIN (EXISTING) DONUTS IF ISDN SERVICE IS NOT REGIONALLY AVAILABLE. o / AREA 6. SEE INTERIOR ELEVATIONS FOR DIMENSIONS AFFECTING THIS WORK. E) (OPTIONAL) 2"x4" ELECTRICAL BOX IN FRONT LINE CHASE WITH 1" CONDUIT OVER 7. SEE SHEET K2 FOR EQUIPMENT CONNECTION REQUIREMENTS. c� c� TO HUB AT MAIN CASH STATION. THIS IS FOR COUNTER MOUNTED VDU UNIT AT ' CT-03 COFFEE STATION. 8. E.C. SHALL PROVIDE MUSIC SYSTEM PER DUNKIN' DONUTS SPECIFICATIONS. SEE POS �j I (EXISTING 9. E.C. SHALL PROVIDE DOORBELLS AND BUZZERS PER DUNKIN' DONUTS SPECIFICATIONS. r t / NOTE :,E,: r i HEIGHT) . K , TOILET 10. E.C. SHALL VERIFY LOCATION OF EQUIPMENT WITH DUNKIN DONUTS FRANCHISE OWNER. . �• (EXISTING) II 5 y PLAN NOTES 11. NOTE: "P.O.S.", ALL POWER OUTLETS FOR P.O.S. DEVICES ARE DEDICATED CIRCUITS WITH THIRD WIRE ISOLATED r, GROUND. AN IG IS AN INSULATED WIRE SEPARATED FROM ALL OTHER GROUND WIRES RUNNING BACK TO THE 5'-0", MAX BUILDING MAIN OR COMPLEX POWER PANEL. NEMA STANDARD L5-15R I.G. FOR THE RECEPTACLE AND PLUG. USE 7 r Al / Al Al Al 1O GYPSUM WALL BOARD CEILING. OF IG DUPLEX OR QUADPLEX OUTLETS: (I.E., HUBBELL IG-5262, IG-5362 OR EQUIVALENT). zr ,5 V' '? L D 4 L D 4711 Al L D 4 O HOOD FOR JUST BAKED OVEN-HOOD SHROUD IS OPTIONAL IF LOCAL JURISDICTION ALLOWS- EXHAUST FAN IS REQUIRED PER DBI STANDARDS. 9S P I A5 O FLUE FOR HOT WATER HEATER. CEILING FINISH SCHEDULE C OHOOD FOR TOASTER - HOOD SHROUD IS OPTIONAL IF LOCAL JURISDICTION ALLOWS. 4. Checked:11/13/2015' " Al DISPLAY EXHAUST FAN IS REQIURED PER DBI STANDARDS. O5 PICK UP SIGN SUSPENDED FROM CEILING CODE MATERIAL MANUFACTURER PRODUCT# DESCRIPTION/,REMARKS 4 LIGHTS FOR �.� WD4 MERCHANDI ER DIGITAL MENU BOARDS TO BE ALIGNED WITH POS STATION AT FRONT LINE- CT-01 GENERAL CEILING TILE ARMSTRONG 1761 WH 2'X4'FINE FISSURED SECOND LOOK II"WHITE" A 1 A17O MAINTAIN 2" CLEARANCE BOTH ENDS OF SYSTEM FOR UNIT VENTILATION. CT-02 NOT USED r ' •, �F} S CT-03 KITCHEN CEI LING TILE ARMSTRONG SHEETROCK LAY-IN 870' 2`X4'VINYL CLAD CE'LINGTILES;"WHITE" SD O7 DIGITAL MENU BOARD (DMB) MINIMUM SOFFIT SIZE: CT-04 CEILING GRID SYSTEM ARMSTRONG 7300 WH WHITE GRID,15/16" --�- n .,• _ -•- - » • 46" DEFAULT SIZE DIAGONAL BOARDS IS 172"L 14'-4" AND 26"H 2'-2' ADJOINING 4-- ( ) ( ) ( ) CT-05 METAL CEILING TILE.' ARMSTRONG 9442U6A1 2'X2'METALINORKS CEILING PANELS' Al Al Al • 40"DIAGONAL BOARDS 149" 12'-5")L AND 23" H (1'-11") ( PX=30 PAINTED GYP.BD. SHERWfN WILLIAMS SW 70061_XTRA WHITE'. FLAT • 4-32"DIAGONAL BOARDS IS 118" L 9'-10" AND 19" H V-7" TENANT LD4 LD4 LD4 ( ) ( ) O8 ACCESS PANEL-CENTER ON POS AT FRONT LINE ' SPACE LIGHTING SCHEDULE i Al Checked:11/13/2015 4X CODE DESCRIPTION MANUFACTURER PRODUCT INTERIORi ` DECORATIVE CEILING S Al 2X4 FLAT ACRYLIC LENS W/3 T8 LAMPS MET 2GR$ 332A UNV-AD IOP3P32SC-U ELEMENTS AS MANUF. Al-EM 2X4 FLAT ACRYLIC LENS W/3 T8 LAMPS(EMERG.BALLAST) MET 2GR8-332A-UNV-EL4 AD-IOP3P32SC-U �! BY DGS - SEE Al Al Al LAYOUT N 0 TE S _ NATIONAL ACCOUNTS, Al-:F FIELD INSTALLED KIT MET FCTKA-24W-U ALSO DETAIL 2/A2. L D 4 L D 4 L D 4 A1P 2X418 CELL PARABOLIC MET 2EP3GX-332S361 UNV AD-IOP3P32SC U 1. PROVIDE EMERGENCY LIGHTS & SMOKE DETECTORS AS REQUIRED BY LOCAL A1Po 2X4 18 CELL PARABOLIC(OVERLAY) MET 2EP3GX-332836I 0/040-UNV AD IOP3P32sC-u w GOVERNING CODE. A2 2X2 9 CELL PARABOLIC MET 2EP3GX2U6-S331-UNV Q �? 2• ADD THE RH REMOTE WEATHER PROOF EMERGENCY HEAD (PRODUCT #Z1PB) TO THE A2PO 2X2 9 CELL PARABOLIC(OVERLAY) MET 2EP3GX2U6-S331-UNV-DL EXTERIOR EGRESS DOORS IF REQUIRED BY CODE.3. NOT USED 0 1 1 4. NOT USED. C TRACK OHOE HEAD SOTYLE FORECAST L703MB Wj 10W'LED LAMP C1 TRACK HEAD-(JAll BREW ONLY) LIGHTOLIER PH 220R30 0 m > I C4 MENUBOARD LIGHT TH50'.-4'-0 ELLIPTIPAR F144-V46 S22-120-LXX W/LENS(COMBO ONLY) j 1L INLAND, DWNLIGHT W REUSE EXISTING GRID; /WHITE TRIM LEV 9875 Li > 0 REPAINT WHITE; NEW FOOTCANDLE NOTES K 42W COMPACT FLUOR.'DOWN LIGHT W/LENS HALO PD7/V142fj7VL1C I� CEILING TILES/LIGHTS AS LP' IOW-BAY 12"RAW ALUM,FINISH ATLANTIC SBS12 242E 1/2PL-24-PL-HSHG SHOWN, TYP 1. MINIMUM LIGHTING LEVEL (FOOTCANDLES IN FRONT OF HOUSE (FOH) = 35FC MIN. LED-1 LED DOWN LIGHT W/RC-6 HOUSING CREE VL6 1027120-SP1/VL6A-SP1 Q 2• MINIMUM LIGHTING LEVEL (FOOTCANDLES IN BACK OF HOUSE (BOH) = 50FC MIN. LED-3 LED 2X4 RECESSED FIXTURE CREE VL24-4035-SP1 w 3• MINIMUM LIGHTING LEVEL (FOOTCANDLES IN TOILET ROOMS = 35FC MIN. LED-4 LED 2X2 RECESSED'FIXTURE CREE VL22-3235-SP1 LED-6 LED 2X4 RECESSED'FIXTURE.(Backroom only); Metalux 2GR-LD1-48 UNV-L835-CD1-U' O LED-7 LED EXTERIOR STRIP LIGHT SLOAN 701912 C175(48"LONG) ` REFLECTEDCEILING & ELECTRIC LIGHTING PLAN P1 HANGING ORANGE PENDANT LIGHT BOCK LIGHTING Pt)5-DD201109 L/TC-4T213(ORIGINAL BLEND) `- P2 HANGING'DECORATIVE PENDANT MODERN LIGHTING 23194-0(CAPPUCCINO BLEND)- SCALE: 1/4" = 1�-0" U IV R E UROFASE L16H IN P3 HANGING DECORATIVE PENDANT(18.5"DIA.) BOCK LIGHTING PO5 DR18OPPP(DARK ROAST) P4/4A HANGING DECORATIVE PENDANT,(6"DIA) BOCK LIGHTING P14-57(FRCISTED OR AMBER GLASS SHADE) -- P5 HANGING DECORATIVE PENDANT(20"DIA.) CON-TECH 17822(JAll BREW-W/DEC CLG COFFER) P6 HANGING DECORATIVE`PENDANT(13.5"DIA) CON-TECH 17374(JAZZ BREW) P2-CO DECORATIVE CEILING ELEMENT DGS(CUSTOM) CAPPUCCINO BLEND(48"X48"X6");,ORANGE SIDES ` A P2-CP DECORATIVE CEILING ELEMENT DGS(CUSTOM) CAPPUCCINO BLEND(48"X48"X6")'PINK SIDES - '" ` CEILING LEGEND P3-Co DECORATIVE CEILING ELEMENT DGS(CUSTOM) DARK ROAST(48"X48"X6")ORANGE SIDES P3-CP DECORATIVE CEILING ELEMENT DGS(CUSTOM) DARK ROAST(48"X48"X6"),PINK SIDES WSCX-2 EXTERIOR WALL MOUNTS I STEM LIGHT JB 24 DECORATIVE CEILING ELEMENT DGS(CUSTOM) JAZZ BREW(24 DIAMETER) JB-36 DECORATIVE'CEILING ELEMENT DGS(CUSTOM) JAll BREW(36"DIAMETER) z C. 2x2 LAY-IN LIGHT FIXTURE O MUSIC SYSTEM NOTES: ( ) GYPSUM BOARD CEILING 1B'-48 DECORATIVE CEILING ELEMENT DGS(CUSTOM) JAZZ BREW(48"DIAMETER) W/OVERLAY TYP. ILI < I- LED-4 O,C OPTIONAL-WALL MOUNTED'OCCUPANCY SENSOR-1NHITE WS WS-200-W Q THE MUSIC SYSTEM IS A REQUIREMENT OF THE BRAND AND O INTERIOR FLUSH CEILING O I STUD FRAMING NO LONGER OPTIONAL. ARCHITECTS TO UPDATE SPEAKER W-EBU 2-HEAD BATTERY PACK EXITRONIX LL50H TO DECK ARCHITECTURAL DRAWINGS PER GUIDELINES DIRECTLY X LED EXIT W/BATTERY EXITRONIX VEX-U-BP-WH' m BELOW. S EXTERIOR SPEAKER COMBO EXIT COMBO LED EXIT/(2)HEAD EBU EXITRONIX VEX U BP-WH EL90-R D VINYL XPANEL E HYING IG LE' 2x4 LAY-IN LIGHT FIXTURE cc) STEEL CABLE TIES- MAINTAIN 6" MIN. OFF (NO - -- - ?. CROSS-BRACING EXTERIOR w, CONNECT TO CLG. GRID EDGE FOR STEEL CABLE 1. MUSIC SYSTEM IS REQUIRED IN ALL NEW AND REMODEL D-3 OVERLAY)TYP. V ADJUSTABLE SPEAKER I� STUD FRAMING STORES. MUSIC SYSTEM TO USE DBI APPROVED Q CJ EXTERIOR AWNING LIGHT MERCURY M4000-1=32 OCT ELB-UNl VOLUME CONTROLS G EYELID WALL PACK-10W LED`` COOPER XTORIA L,1_J G.W.B. OVER 5"PLYWOOD PROGRAMMING 8 2x4 LAY-IN LIGHT FIXTURE (W/ GF 100W MH GROUND FLOOD LTH TFM100MTA TB DBL LPI -•- EXIST HEIGHT SEE ELEVATIONS FOR HANGING PENDANT LIGHT FIN CLG• �- - 2. ALL CEILING SPEAKERS TO BE FLUSH MOUNTED WHITE. LED-6 OVERLAY)TYP. P4 LED-2 EXTERIOR 3"LED FIXTURE CONTRAST'UGHTING CA2550/REFRE2550-CL/CA2550-01 PAINT COLOR ALL EXTERIOR SPEAKERS TO BE BLACK,WITH EXTERIOR RH EXT.WEATHERPROOF'EM REMOTE HEAD. EX ZIP-2L1- CROSS-BRACING GRADE CONSTRUCTION. eX EXIT SIGN SVL-22F-3 SITE LIGHTING USA SVL22F-III-350PS-MT-I-DBM-LAMP--SNTS-204-11-1-DBMV11- ' --� 2x4 LAY-IN LIGHT FIXTURE (W/ STUD FRAMING 3. ONE SPEAKER IN EACH BATHROOM TO BE FLUSH ACRYLIC LENS)TYP. ® RETURN/CEILING LL° MOUNTED WHITE. Al EXHAUST REGISTER TIC DIGITALTIME CLOCK TORK DTS200A DECORATIVE CEILING G.W.B. PX-30 WSC-1 EXTERIOR BLACK UP/DOWN SCONCE W/LENS SLID 8340 10/9008-12 ELEMENT BY DGS-SEE SUPPLY AIR DIFFUSER- ( ` ' 4. A MINIMUM OF TWO SPEAKERS IN THE SEATING AREA(NO 0 RECESSED CAN DOWN LIGHT 4 WAY WSCX-2 SIGNLITE FIXTURE'W118"ARM W/LAMP' H17LITE H HDMR16/18-1-119/50W/LV-BCM-M/B0112830 ; PREFAB CEILING ELEMENT NATIONAL ACCOUNTS) -- -- SPEAKERS IN THE SERVICE AREA). LED-2 FIXTURE (LED) WSR EXTERIOR ARCH,WALL PACK-175W'MH COOPER' XTOR3A BY DGS (SEE NATIONAL ELEV.6"-10" �C _ ACCOUNTS) LIGHT FIXTURE BY G.C. 5. A MINIMUM OF TWO SPEAKERS AT EXTERIOR SEATING DOWN LIGHT FIXTURE (LED) TRACK HEAD& LED LAMP LIGHTING SCHEDULE NOTES SH EE , ` AREAS WHERE APPLICABLE. (AVAILABLE THROUGH G 1. PROVIDE ALL FIXTURES COMPLETE WITH LAMPS. REFER TO NATIONAL ACCOUNT SOURCE INFO FOR LAMP SPECS&`VILLA'LIGHTING RE-LAMPING VILLA LIGHTING-SEE ' EXTERIOR WALL PACK EQ. EQ• RECESSED LIGHT FIXTURE 6. SPEAKER AT EXTERIOR OF BUILDING ADJACENT TO 0 RECESSED CAN EXTERIOR PROGRAM.ALTERNATES FOR DRYWALL OR EMERGENCY FIXTURES CAN BE FOUND UNDER NATIONAL ACCOUNTS. i NATIONAL ACCOUNTS) " :: LED-1 DOWN LIGHT FIXTURE LED LIGHT -1 LED-1 (SEE REF.CLNG PLAN ENTRY. (LED) m FLUE 2. ALL INCANDESCENT LAMPS SHALL BE RATED 130 VOLTS `'; FOR LOCATIONS-TYP.) 3. ALL BALLASTS SHALL BE HIGH POWER FACTOR. FLUORESCENT BALLASTS FOR T8 LAMPS TO BE ADVANCED MANUGACTURED OPTANI UM WATT MISER, 7. PROVIDE AND INSTALL SEPARATE VOLUME CONTROLS -�- PENDANT LIGHT FIXTURE (LED) SUSP. CLNG GRID SYSTEM EXCEPT OUTDOOR FIXTURESTO BE ZERO DEGREE MAGNETIC BALLASTS.FOR EACH AREA(RESTROOMS, SEATING AREA, P3 W/ACOUSTICAL OR VINYL " EXTERIOR WITHIN HANGING SOFFIT 4. PROVIDE HOLD DOWN CLIPS FOR EACH CORNER OF FLUORESCENT'GRID TROFFERS. CLAD CEILING TILES-SEE _ JOB . D OC 5. PROVIDE ALL REQUIRED MOUNTING OR HANGING HARDWARE _- _..._ . EXTERIOR UP/DOWN SCONCE PLAN FOR TYPES AND - I 8. HARDWARE TO BE INSTALLED IN THE OFFICE. FIELD WSC-1 6. COORDINATE AND VERIFY ALL FIXTURE INFORMATION,TYPES AND FINAL LOCATIONS WITH THE REFLECTED CEILING PLAN. DATE: O3/� J/ 2 DECORATIVE COFFER 1 SOFFIT DETAIL LIGHT LOCATIONS .. M VERIFY AND COORDINATE WITH FRANCHISE FOR THE 7. LAMPS SHALL BE AS MANUFACTURED BY SYLVANIA WESTINGHOUSE,GENERAL ELECTRIC OR APPROVED EQUAL, n 1/2" =1'-0" 3/4" -1'-0" EXACT LOCATION OF THE UNIT AND VOLUME CONTROLS. NOTE: SEE ELECTRICAL DWG'S FOR MORE INFORMATION ON LIGHT FIXTURES. PCB: 330360 C.M. V. LAi 0i_'L `' LINE OF DROP CEILING LINE OF DROP CEILING ARTWORK PACKAGE - MAINTAIN 3" MIN. LINE OF DROP CEILING ARTWORK PACKAGE - MAINTAIN 3" MIN. LINE OF DROP CEILING .•- , WC—Ot PT-07 FROM CEILING, AND 3" ABOVE KNEE WALL WC-01 PT-07 FROM CEILING, AND 3" ABOVE KNEE WALL. PT-06 I - I II I I I) II i z z Z I �� Z Z z z N N (� F w w w o LINE OF � �� w �� w �� �� x X COUNTERS / w (HALL w /// BEYOND) WC-01 PT-07 PT-06 EXISTING DOOR & yyg_01 WB-02 WB-01 EXISTING ALUM SEATING AREA ABOVE N T DRAWN ® TRUE ANGLE NOT DRAWN ® TRUE ANGLE + ALUM STOREFRONT STOREFRONT ® GLAZING CHAIR RAIL SEATING AREA ABOVE CHAIR RAIL VESTI U LE SALES AREA ELEVATIONS ;. SCALE: 1/4 = 1 -0 CO CEO WT-01 WT—Ot WT-01 WC-07 14'-4" LINE OF DROP CEILING WT-05 WT-05 MENU BD. WT-05 > r DMB MINIMUM SOFFIT SIZE FOR 4 — 46" - FASCIA DIAGONAL BOARDS IS 172"L X 26" H ACCENT ACCENT ACCENT ONLY ' is 4L„ DATA 2>, ® Im ! r EXHIUST 9 p VD HO I.C.B. HWB z ,R � l 4� I BLENDERS E- ^ [ I e ., OASIS .. _ cn cn - rj AND = v� cn � 7 X (SERVING x INK i; .,H w LINE OF x - � r w o o �� �A COUNTER o c u :,g AREA ��, DISPLAY � ° DISPLAY ..._. I ° g (PREP i '"� CASE CASE �, .. °° w BEYOND) �.: _ -----1� AREA ki � : � ..� ' BEYOND) � � ��i � , C OLAT Al �. ........- ... JK 12 12..., ... _. _. . > � t � l NOT DRAWN @ TRUE ANGLE -, (/4—TILE-SEE ELEVATION BELOW WB-02 yyg-02 NOT DRAWN C� TRUE ANGLE CONTINUE TILE AROUND WALL 8 9 10 11 FINISH'. MATERIAL SCHEDULE - ORIGINAL BLEND A10 A10 A10 A10 UPDATED: 11/13/2015 ae SERVING AREA ELEVATIONS � � CODE MATERIAL MANUFACTURER. PRODUCT# DESCRIPTION REMARKS � SCALE: 1/4 = 1 -0 COLOUR SCHEME B909 ARTISAN CUT 12, X12 ` FLOOR TILE:W/SATIN NICKEL SCHLUTER STRIP n it t� WB-01 CERAMIC TI LE DAL TILE WT-01 BROWN"' CAP JOLLY-ANIGB � WC-07 COLOUR SCHEME B909 "ARTISAN MENU BD. WT-05 14'-4" WB-01 ALT CERAMIC TILE DALTILE 6"X12" COVED BASE TILE(OPTIONAL UPGRADE)' DMB MINIMUM SOFFIT SIZE FOR 4 - 46 BROWN"#B909P36C9TB1P2 FASCIA ACCE T DIAGONAL BOARDS IS 172"L X 26" H F ONLY QUARRYTILE Q3565"SAHARA; 5"X6" COVE BASE-SEE NATIONAL ACCOUNTS FOR WB-02 QUARRYTILEI DALTILE SAND" INSIDE/OUTSIDE'CORNER PRODUCT NUMBERS c.c� a� W j DATA PT-01 PAINT SHERWIN WILLIAMS 6372 "INVITING IVORY": SATIN FINISH 2.. PT-02 PAINT SHERWINWILLIAMS 6884 "OBSTINATE ORANGE" SATIN FINISH (INTERIOR) o I TILE START PT-03 PAINT SHERWIN WILLIAMS 6140 "'MODERATEWHITE": SATIN FINISH C/) z POINT PT-04 PAINT SHERWIN WILLIAMS 6099 "SAND DOLLAR": SATIN FINISH m cn X - PT-05 PAINT SHERWIN WILLIAMS 7536 "BITTERSWE'ETSTEM": SATIN ui o (SERVING i AREA PT-06 PAINT SHERWIN WILLIAMS 7724 "CANOE": SATIN > G � BEYOND) PT-07 PAINT SHERWIN WILLIAMS 6117 "SMOKEYTOPAZ SATIN' Ljj ' PT-08 PAINT SHERWIN WILLIAMS 6096 "JUTE BROWN SATIN un PT-09 PAINT SHERWIN WILLIAMS 6097 "STURDY BROWN"; SATIN w ~ 3"X6" ACCENT TILE- PT-10 PAINT SHERWIN WILLIAMS 6090 "JAVA'": SATIN WT-01 START ACCENT TILE (NO WORK) o TWO COURSES DOWN PT-11 PAINT SH ERWIN W1 LLIAMS 6069 "FRENCH ROAST": SATIN z I WB-02 PT-12 PAINT SHERWIN WILLIAMS 6006 "BLACK BEAN": SATIN _...._wM_.._ 4"X 16" FIELD TILE-BACKLINE WALL& AS INDICATED IN BACK — BAR WT-01 WALL TILE DALTILE ELEVARE EL41 "CRATER" 3 10 ELEVATI'0NS- USE W/GROUT G-02 SCALE: 1/4" = 1'-0" A o RITTENHOUSE'SQUARE 0190"ARTIC ` (NO WORK) Alo WT-01A WALLTILE DALTILE WHITE COMBO' ONLY CRISP AND MOIST HOT HOLD o DUAL LANE SMART TOASTER RITTENHOUSE'SQUARE 0766 4"X 16"ACCENT TILE- BACKLINE WALL-AS INDICATED IN < HOLDING UNIT WT-02 WALLTILE DALTILE 4 - $ "ELEMENTAL TAN" ELEVATIONS--USE WJGROUTG-02 REFRIGERATED WORK TOP WITH 4 DRAWERS VDU Al CERAMIC TILE- Q09736MODlP 3`"X6"ACCENT TI LE- RESTROOM WALLS AS I NDICATED I,N "` ' + { DATA AND POWER WT-03 WALL TILE DAL TI LE (NO WORK) "ORANGE BURST" ELEVATIONS- USE W/GROUTG-03 Li6°° 6„ Al _— OPTIONAL UNITXH MODERN DIMENSIONS 0161 4"X 16" FIELD TILE- BACKLINE WALL,3"X6" FIELD TILE- RESTROOM 0 HASH BROWN WARMER EXHAUST HOOD WT-04 WALLTILE DAL TILE "URBAN PUTTY" WALLS-AS INDICATED IN ELEVATIONS USE W/GROUTG-43 Q TURBO CHEF — NO WORK U O 7 RITTENHOUSE SQUARE 0761 4 1/4"X12 3/4" FIELD TILE-'RESTROOM WALLS AS INDICATED IN _j PRINTER Al WT-04A WALLTILE DALTILE �, ELEVATIONS- USE W' GROUTG-03 URBAN PUTTY / o ( - 6 8"X8 'TILE IN A 45 DEGREE DIAGONAL PATTERN- BR BACKLINE, USE � W Al WT-10' WALLTILE DALTILE POLARIS'PL02881P2 "GLOSS WHITE " WJGROUTG-02 (COIVIBOONLY) QD w3 ■ co rn - 8"X8"TILE I N A 45 DEGREE DIAGONAL PATTERN- BR BACKLf NE, USE - WT-11 WALLTILE DALTILE POLARIS PL22"GLOSS ALMOND" ® PRINTER W/GROUTG702 (COMBO ONLY) _ DATA AND POWER FIRP-01 FIBERGLASS REINFORCED PANELS MARLITE P100"WHITE" BOH/KITCHEN AREAS NOT IN PUBLIC VIEW' .a 5 4 3 FRP-01ALT FIBERGLASS REINFORCED PANELS CRANE KEMLITE 85`"WHITE" BOH/KITCHEN AREAS NOT IN PUBLIC VIEW1-4 Al FRP-02 ALT FIBERGLASS REINFORCED PANELS PANOLA'M CLASSIC COLLECTION WHITE BOH/KITCHEN AREAS NOT IN PUBLIC VIEW I s PL-04 PLASTIC LAMINATE WILSONART' 10669-60 "CITRUS ORANGE" FRONT LINE MILLWORK- HEADER/SHROUD FINISH ` 4'-4" 4'-9" PL-05 PLASTIC LAMINATE FORMICA #)932-58 "ANTIQUE WHITE" FRONT Li NE MILLWORK-GATE/END PANEL, CONDIMENT STATION ; FINISH 01 6'-2°° CUSTOM BUILDING 6'-11" 1 Al G-02 GROUT PRODUCTS #333 It FOR USE WITH BACKLINE WALL TILE SHED ` 8'-7" Al CUSTOM BUILDING G-03 GROUT #382 BONE FOR USE WITH RESTROOM WALLTILE 9°0" PRODUCTS USE FOR INDICATED ACCENT WALL IN SALES AREA DESIGN' S 9'-21/4" WC-01 WALLCOVERING APA COLOR GRAPHICS DD "FRESFi.BREW"TEXT'1NALLCOVERING SEE ELEVATIONS FOR LOCATION _.._,. ........ WC-03 WALLCOVERING APA COLOR GRAPHICS BR"HERITAGE"TEXT WALLCOVERING USE FOR ENCLOSURE WALLS AND SOFFIT OVER CAKE CASE (COMBO JOB#: D 160�' u STATION PLAN ONLY- MAY NOT BE PRESENTIN ALL.DESIGNS) DATE: 03/i ,'SANICI I KEY DD"FRESH BREW"TAN MUTED LETTERS . SCALE: 1 4" = 1'-0" WC-07 WALLCOVERING APA COLOR GRAPHICS USE FOR MENU BOARD FASCIA PC 33036U / SCALE: N.T.S. WALLCOVERING # C.M. V. LANGLE_ ROOM FINISH SCHEDULE DB-NOTES-TITLE CZD Checked: 11/13/2015 NOTE: MITER ENDS AND COPE BACK AS FOR COMPLETE NATIONAL ACCOUNTS SOURCE INFORMATION, REFER TO THE FLOOR BASE CODE WALL CEILING NOTES DUNKIN' BRANDS NATIONAL ACCOUNT WEB SITE ( http://extranet.dunkinbrands.com). TO REQUIRED FOR FINISHED ENDS NO. ROOM NAME CODE CODE CODE OBTAIN A USER NAME AND PASSWORD PLEASE CONSULT YOUR LOCAL 1 FINISH NAIL ENDS 101 SALES AREA FC-01 WB-01 NOTE#1 CT-01 1,3,4 CONSTRUCTION MANAGER Y4 BEVELED EDGE SECTION A-A NOTE: 102 SEATING AREA FC-02 WB-01 NOTE#1 CT-01 1,3,4 ""„�--• REFER TO FLOOR PLAN SQUARE STEEL CORE DRILL TOP OF WALL TRIM AT NOTE: BASE -SEE DUNKIN' BRANDS HIGH TABLE ELEV. 3'-7" 5/" GYP. BD 103 DRIVE THRU FC-05 WB-02 FRP-01 CT-03/PX-30 3 4 ' FOR LOCATION OF ADA CONTRACTOR TO IDENTIFY ONESELF AS WORKING WITH DUNKIN' BRANDS WHEN TABLE BASES 2 SPECIFICATIONS & EQUIPMENT TOP OF WALL TRIM AT 104 SERVICE AREA FC-OS WB-02 NOTE#1 CT-03/PX-30 1,3,4 ORDERING FROM NATIONAL ACCOUNTS PLAN TABLE ELEV. 2'-6 1/2" 105 MEN FC-01 ALT N/A NOTE#1 PX-30 1,2,3,4 ACOUSTICAL CEILING TILES&GRIDS(ALL REGIONS) EXTERIOR INSULATED FIBERGLASS SYSTEMS(EIFS) WATER FILTRATION SYSTEMS yl6"THICK, 4Y2" DIAMETER �� 106 WOMEN FC-01ALT N/A NOTE#1 PX-30 1 2 3 4 ARMSTRONG WORLD INDUSTRIES DRYVIT SYSTEMS,INC. (ALT TO RO SYS WHERE APPLICABLE) BOTTOM OF WALL _ _ SHERRY BRUNT OR PHYLLIS MILLER-ORDERS N.E.SALES MANAGER:MIKE LEROY BUNN-O-MATIC CORPORATION w STEEL COVER PLATE, FOR FLOOR FINISHES SEE TRIM ELEV. 2'-3" Ys" REVEAL 107 OFFICE FC-05 WB-02 FRP-01 PX-30 2,3,4 P: 1-800-442-4212 P:(857)829-0016 WENDYPEPER-ORDERS WELDED TO COLUMN FLOOR FINISH PLAN EMAIL:BPO STRATEGIC ACCOUNTSOARMSTRONG.COM F:(627)625-6866 P:800-646-2866 STAIN TRIM. REFER TO 10$ KITCHEN FC-OS WB-02 FRP-01 CT-03 3 4 REFERENCE:DUNKIN:BRANDS,INC. STRATEGIC ACCOUNT MIKE.LEROY(a),DRYVIT.COM F:800-286-6339 EASED EDGE REPRESENTATIVE: ROBERTD.WILLIAMS WWW.DRYVIT.COM E:WENDY.PEPEROBUNN.COM DRAWING SET FOR"TRIM" P:1 877-ARMSTRONG,OPTION 8,EXT 8052 TECHNICAL SUPPORT HOTLINE: ~ 109 ALCOVE FC-01 WB-01 NOTE#1 CT-03 1,2,3,4 F:717-3978089 LAMINATES 1-800-800-0657 PROMPT 5 STAIN FOR EACH CONCEPT. WALL FRAMING ' fr RDWILLIAMSR�ARMSTRONG.COM FORMICA Q q N CITES WWW.ARMSTRONG.COM/CEILINGS FOR LOCAL DISTRIBUTOR CALL AWNING FABRICS AND VINYL: d d u NOTES: KAREN KENNEY ARLON: �»- a. 1. REFER TO INTERIOR ELEVATIONS FOR PROPER WALL FINISHES IN DESIGNATED AREA SALES AREA,SERVICE/KITCHEN FLOOR&WALL TILES 86s-573-3512 ELAINEHALL-CUSTOMER SERVICE Ch s ° ch 1. 1. TRIM TO BE FURNISHED AND INSTALLED BY MILLWORK DAL TILE E:K.KENNEY(2DFORMICA.COM T:(800)854-0361 EXT.1310 REPRESENTATIVE:PAULA TOSTI REP:JEAN MARIE REMICK F:(973)727-6595 ° VENDOR 2. SEE INTERIOR ELEVATIONS FOR DOOR FINISHES P: 978-461-2928 0:(781)235-4165 EMAIL:EHALLa()ARLON.COM .d d �� °' 2. 2. WALL TRIM TO BE SOLID MAPLE (STAINED)WITH 3 COATS OF F: 978-461-0374 C:(617)217-8146 REPRESENTATIVE:KEVIN ROURKE ° 4 3. PROVIDE ALUMINUM CORNER GUARDS ATALL OUTSIDE CORNERS OF WALLS SEE FLOOR E: PAULA.TOSTIADALTILE.COM JEANMARIE.BISSON@FORMICA.COM 843-388-1364 ---- - -_--- ------ °q d S.W.A68 SERIES POLYURETHANE ' WWW.FORMICA.COM C:973-727-6595 3. 3. WALL TRIM TO BE SOLID MAPLE (STAINED)WITH 3 COATS OF PLAN FOR LOCATIONS VINYL COVEBASE KROURKE(�ARLON.COM 3 S.W.A68 SERIES POLYURETHANE CALL EARMSTRONG CUSTOMER SERVICE FORS:LOCAL ARMSTRONG FLOORING R LOCAL FORFOR ORDERS CALL WILSONART WWW.ARLON.COM Nt;a 4. G.C. TO VERIFY ALL FINISHES WITH DBI CM PRIOR TO ORDERING MATERIALS. DISTRIBUTOR 800-433-3222 FOR A LOCAL DISTRIBUTOR. ORANGE BOLLARD COVERS „ 4. 4. FASTEN CHAIR RAIL TO STUDS. PROVIDE BLOCKING AS INFORMATION:1-800-442-4212 OPT.2 REPRESENTATIVE:AMY MORGENWECK IDEAL SHIELD 1/4 HOLD SETTING MATERIAL REQUIRED REFERENCE:DUNKIN'BRANDS PRICING P:917.951.6524 ORDERS:PETE MURPHY ACCOUNT MANAGER E:MORGENAaWILSONART.COM T:313-551-2288 5. 5. WALL TRIM IS INTENDED TO PROTECT THE WALLS FROM P:717-209-8793 F:866-413-9243 "L EMAIL: SLACKERMANPARMSTRONG.COM DRIVETHRU WINDOWS PMURPHY@IDEALSHIELD.COM +` DAMAGE FROM TABLES. INSTALL TRIM ON WALLS ONLY IN WWW.ARMSTRONG.COM/FLOORING READY ACCESSORDERS- KIM MCKIBBEN EXT 120 REP&ORDERS:DENNIS KNITTEL " LOCATIONS WHERE TABLES MAY IMPACT THE WALLS. THIS (800)621-5045 OR FAX(630)876-7767 T:313-551-2283 TRIM TYPICALLY WILL NOT BE USED IN ENTIRE DINING ROOM EPDXY FLOORING EMAIL: KIMTDREADY-ACCESS.COM C:313-550-7760 STONHARD WWW.READY-ACCESS.COM DKNITTEL@IDEALSHIELD.COM CC) REPRESENTATIVE: SCOTT GARSTKA 2ND CONTACT:PATRICK MEADE QUIKSERVORDERS:CALL 800-388-8307 OUTSIDE FURNITURE:(LIGHTWEIGHT) C:413-237 9267 ASK FOR STEVEN BERT OR JACKIE SLIGH ORDERS:ALEX JARVIE C P:800-854-0310 OFFICE X-5158 REPRESENTATIVE STEVEN BERT- ALEX@CHAIR.COM M 6r,, 1 F:856-321-7510 P:(800)368-8307 1-800-387-6488 EXT 229 p ` EMAIL: SG AR F:713-849-5708 REP:MIKE DISTASIO MIKE@CHAIR.COM WWW.STONHARD.COM SBERT@QUIKSERV.COM 1-800-387-6488 EXT 223 ; WALL COVERINGS: DRIVE THRU CANOPY/SPEAKER&CLEARANCE BAR UMBRELLAS: n. APA COLOR GRAPHICS EVERBRITE ORDERS:LAYTON UMBRELLAS ` R a> 1 CORE DRILL TABLE DETAIL 2 WALL TRIM ORDERS:CHUCK R(404 OR DALE DRANE 494E S.1 ELD,STREET P: 856-229-1958 - P:(800)543-5775 OR(404)355-1355 GREENFIELD,WI 53228 F: 856-222-4712 F:(404)355-1359 ANA DOMINGUEZ REP:JONATHAN LAYTON N.T.S. NOTE: 1-1/2"=1'-O" NOTE: EMAIL:DALEAAPACOLORGRAPHICS.COM OR P:(414)529-3500 LAYTONSUMBRELLAS(a)COMCAST.NET y"r ( " CHUCK(MAPACOLORGRAPHICS.COM OR F:(877)430-7364 a £' �) DUNKINORDERS(cDAPACOLORGRAPHICS.00M NESCO(ELECTRIC PANELS&BREAKERS ) DRIVE THRU HEADSETS ORDERS: 1"X MAPLE CAP ARTWORK PACKAGE- MAINTAIN 3" PAINT 3M BUILDING AND COMMERCIAL SERVICES DIVISIONS P: 800-244-6980 FROM CEILING AND 3"ABOVE ORDERS/REPRESENTATIVE:MICHELE PISHKO F: 781-575-1398 VAR S COORDIN TE STAIN-SEE FINISH SHERWIN WILLIAMS BUISNESS DEVELOPEMENT NATIONAL ACCOUNTS EMAIL: DUNKINBRANDS(a�NESCOWEB.COM SCHEDULE BOOTH BACK REPRESENTATIVE:MARK T.WEINER,CSI P:(651)736-1629 WWW.NESCOWEB.COM �A 4 WITH G.C. P:401-245-5176 C:(651)271-7706 ie F:401-245-5163 E:MMPISHKO@MMM.COM TANKLESS HOT WATER HEATERS EASED EDGE C:617-438-1408 WWW.3M.COM/FOODSERVICE RINNAI EMAIL:MARK.T.WEINER(a�SHERWIN.COM ORDERS:VELEEKA DUDLEY WWW.SHERWINWILLIAMS.COM HM ELECTRONICS,INC.(HME)ORDERS T:866-383-0707 q YF NOTE: PROVIDE EASED 14110 STOWE DRIVE VDUDLEY@RINNAI.US :, I EDGE AT ALL 90 DEG. TRIM O FIBERGLASS REINFORCED PANELS(F.R.P) POWAY,CA92064 REPRESENTATIVE:BRIAN ROUNTREE "� 'w MAPLE WOOD CAP ' MARLITE CORPORATION T:858-535-6060 OR 800-848-4468 T:770-577-6601 t OPTION A OR B INTERSECTIONS (TYP.) ORDER DISTRIBUTOR LISTED BELOW: REPRESENTATIVE-LISAJOKINEN C:404-915-5660 I 4" OVERHANG `� DOVER,OH:(330)364-7561 OR(330)343-6621 F:858-552-0139E:LJOKINENCMHME.COM BROUNTREE@RINNALUS y GRAND PRAIRIE,TX(972)660-6443 WWW.HME.COM/DD WWW.RINNAI.USMA p PT-07 SANTA FE SPRINGS,CA:(562)926-7208 \ 1"X3" MI�1 ' J REPRESENTATIVE: JAMIE MCEDWARD DRIVE THRU TIMERS HVAC ROOFTOP UNITS MAPLE cY / P:800-377-1221 OR 603-924-9128 HYPERACTIVE TECHNOLOGY TRANE F:330-343-4668 P:877-334-9737 NATIONAL ACCOUNT MANAGER: \ / TRIM m TOP OF C:330-260-7627 F:412-322-3121 JONATHAN RALYS �r xi BOOTH WWW.MARLITE.COM FOR PHONE,PRESS OPTION 1 TO REACH SALES P:781-305-1335h WALL TRIM IF ADJACENT - TECH SUPPORT:T.J.RINE 330-602-2213 F:781-938-6912 CORE DRILL CONC. FLR.; CO C _ RESTROOM FIXTURES AND ACCESSORIES E:JONATHAN.RALYS@TRANE.COM ti �y�1y OPTION A-WOOD CAP PROVIDE 2" PIPE TO BE TO TABLES (SEE DETAIL) cr 00 CRANE COMPOSITES(KEMLITE) NEWTON DISTRIBUTION COMPANY,INC. WWW.TRANE COM �ax� w '� CALL MANUFACTURER FOR CLOSEST 966 WATERTOWN AVE. p " SET IN HIGH STRENGTHIle DISTRIBUTOR:800-435-0800 NEWTON,ma02465 CARRIER CORPORATION 9� VAR S COORDINATE MORTAR 48" O.C. _ 1/2" BRUSHED REFERENCE:NPP PROGRAM REPRESENTATIVE:LANCE LAFAVE OR NATIONAL ACCOUNT MANAGER: �, @ PT-06 REPRESENTATIVE:ROBERT MURPHY SCOTT CASSIDY PAUL WITZ N WITH G.C. (FOR STRAIGHT RUNS) °O ��� ON GYPSUM ALUMINUM CORNER c:7s1-s2s-15sa ORDERS: P:315-432-3982 it M �' F:761-987-1072 P:877-837-7745 F:860-998-1403 �,,, � 2 CM POLISHED — c� GUARDS AT ALL WB-01 PT-04 EMAIL: RMURPHY@CRANECOMPOSITES.COM F:617-969-4071 E:PAUL.WITZ@CARRIER.UTC.COMs OUTSIDE CORNERS WWW.CRANECOMPOSITES.COM P:877-837-7745 SEE NATIONAL ACCOUNTS PAGE FOR W STONE CAP WB-01 LOW WALL WWW.NEWTONDISTRIBUTING.COM MARKET SPECIFIC CONTACT 1/8" EASED 2A NOTES: LIGHTING FIXTURES:INTERIOR&EXTERIOR INFORMATION a v EDGE / Y o"'' '' -' LFINISH FLOOR A-3.0 1. ARTWORK SHOULD ALWAYS BE PLACED 42" FROM FLOOR TO MELANIE ADAMS-ORDERS CAPTIVE-AIRLLA LIGHTING KITCHEN ODS/EXHAUST SYSTEMS WWW.CARRIER.COM BOTTOM OF ARTWORK ON OPEN WALLS P:(B00)325-0963x462 DAVIDCRITTENDEN I METAL STUD REFER TO FLOOR F:(314)531-8720 P:813-435-3368 EXT-2 _. �" OVERHANG PLAN 2. ARTWORK TO BE INSTALLED WITH 3" SPACING BETWEEN EMAIL: M ELAN IE.ADAMSaVILLALIGHTING.COM F:813-354-4825 4 / PANELS W W W.VI LLALI GHTI NG.COM REF62(�CAPTIVEAI RE.COM � REPRESENTATIVE: STEVE DEMARAIS WWW.CAPTIVEAIR.COM CO 1"X3" MAPLE 3. ARTWORK SHOULD ALWAYS BE PLACED 3" FROM TOP OF P:508-668-3159 Ln TRIM / C:508-878-0027 HORACIO'S WELDING&SHEETMETAL W QUE LINE TILE DINING AREA TILE END CAP ELEVATION BOOTH EMAIL: STEVE.DEMARAIS(idVILLALIGHTING.COM REPRESENTATIVE:MICHAELTAVARES Q j / 4. DEFAULT HEIGHT FOR ARTWORK IS 5' P:508-985-9940 LIGHTING FIXTURES:INTERIOR&EXTERIOR F:508-985-9965 \ SECTION 5. USE 4 HIGH ARTWORK FOR CEILING HEIGHTS BELOW 9-9 NEEDHAMLIGHTING EMAIL: MIKE(W_HORACIOS.COM STAIN-SEE LINDSEY MILLER P:(781)737-1019 F:(781)575-1398 WWW.HORACIOS.COM FINISH SCHEDULE 6. USE 6 HIGH ARTWORK FOR CEILING HEIGHTS ABOVE 10-6 EMAIL: LINDSEY.MILLER(cDNEEDHAMELECTRIC.COM 7. STORES THAT CANNOT ACCOMMODATE THIS MINIMUM WILL WWW.NESCONATIONAL.COM KITCHEN SWING DOOR Z >- (n j OPTION B-STONE CAP ELIASON CORPORATION �] NOT HAVE ARTWORK PIVOTING CANOPY(OPTIONAL)AT DRIVE-THRU KALAMAZOO,MI O_ SPEAKER&CLEARANCE BAR REPRESENTATIVE:JOE DUSENBERY OR ORDERS:MARTINE ROBERSON MARIA DAHLINGER Z W 3 SECTION HALF WALL DETAIL 4 ARTWORK M.ROBERSON@UNISTRUCTURES.COM P:(800)828-3655 P:800-386-9864 F:(800)828-3755 3/4"=1'-O" NOTE: 1/4"=1'-0" NOTE: F:770-544-0787 CA SALES OFFICE 800-828-2655 W � REPRESENTATIVE:KEITH E.SEBREE EMAIL: DOORS(aDELIASONCORP.COM P:800-386-9864 X227 C:404-925-6833 COMING SOON BANNERS U Q EMAIL: K.SEBREE(cDUNISTRUCTURES.COM GO TO:HTTP://WWW.LSMNOW.COM/ W I_ LSMNOW.COM HELPDESK:888-457-6669 Z "D"DOOR HANDLES: — MICHAEL HEALY DESIGNS WATER FILTRATION --- MANVILLE,RI Q �� P:800-995-0988 WATER QUALITY REQUIREMENTS: Z OR 401-765-7600 HEAVY DUTY WATER BOOSTER SYSTEM F:401-765-7612 MCCANN'S ENGINEERING&MFG.CO.: - - - •---- EMAIL:HEALYDESIGNSPAOL.COM ORDERS:ELEANOR HINSON OR HARRY HALL I P:818-637-7219/818-637-7285 P&G CLEANING AND SANITATION PROGRAM F:818-637-7222 PROCTOR&GAMBLE EMAIL: ELEANOR.HINSON@MANITOWOC.COM OR REPRESENTATIVE:CARLA EVANS HARRY.HALL(a)MANITOWAC.COM P:513-983-9599 EQCINCINNATI.IMPPG.COM EVERPURE(APPROVED VENDOR#1): I WATER TESTS:(FREE). EMAIL: TWMnEVERPURE.COM STORE GRAPHICS OR WWW.EVERPURE.COM DGS RETAIL INC. "DUNKINWORKS" ^- - ORDERS:DUNKIN'BRANDS DESK ORDERS AND SERVICE INSTALLS: 508-337-2990 EVERPURE MASTER DISTRIBUTORS(MD) REPRESENTATIVE: SEE WWW.EVERPURE.COM FOR LOCAL MD KAREN MCCUE OR TOM ROONEY -CONTACT DCPS FOR INSTALLATION AND 1 ` KARENMCCUE@DGSRETAIL.COM OR THEY WILL DIRECT YOU TO YOUR LOCAL EVERPURE TOMROONEY@DGSRETAIL.COM MASTER DISTRIBUTOR I P:508-337-2990 r Q L� F:508 337-5040 NATIONAL ACCOUNT REP:JASON RYKKEN CD I ' I ram. WWW.DGSRETAIL.COM EMAIL: JRYKKEN(cDPENTAIR.COM L 3 1 •% I 1 f F:952-426-9742 ROOFING: O I DURO-LAST ROOFING INC. 3M WATER FILTRATION(APPROVED VENDOR#2) lw r ORDERS:JOHN ROBINSON NATIONAL ACCOUNT REP:DAVID RADLIFFE Q P:800-248-0280 x2210 P:518-281-7754 U J 1 L Ii !„I I F:800-432-9331-FAX F:203-238-8701 JROBINSO@DURO-LAST.COM E:DPRADLIFFE@MMM.COM J, , REPRESENTATIVE:BLU BARTES P:800-248-0280 x222 ORDERS&WATER TEST KITS m � "� WWW.DURO-LAST.COM AWS DISTRIBUTING(TESTING COMPANY FOR 3M) O REPRESENTATIVE:KRISTINAVILLA � ) CEILING TILE PROTECTION: P:800-333-2866(CUNO) d I AIRTECH,LLC F:630-836-1793 � P:(877)287-7739 EMAIL:AWSDISTRIBUTING@SBCGLOBAL.NET p a WWW.AIRTECHINSERTS.COM -�' e ",J , •, L�lj J SHEET JOB#: D1600- DATE: 03 '15 11 C.M. V. LA,NGLEy' r i 0 HANDSINK ..�._...—...__ ...__ ®._ NOTE: F'EE AND FIELD TEAM TO DETERMINE IF EXISTING BACK ' ROOM EQUIPMENT AND COLD/DRY STORAGEr CAPACITIES CONFORM TO CURRENT STANDARDS. „6 -- PREP m AREA A KIT. ✓� OFFICE ICE (EXISTING) HALL N� V EXIST. u FILLER N � - (EXISTING) COL O E (EXISTING) �C/� ��O r P H GHT :fAl Y B KE YICB STA. - �. A.L A O° ° L--------------- --------�-�----f-i-a--t-------------- --------- L ,-\ ca Winter DMB \�SEE NOTE#4 t`� c° w NEW ry g� 46 DMB Needs 172 L°nd 26 H ���A, h H.W. 5-8 � \Ory COFFEE STATION POS STATION s � r ��;OEXISING W fi � s o p f RESTROOM -Z ,�N t ® � SERVING a�\•,ry � wo c° ® AREA VDU EXISTING CD C41 RESTROOM - - Q RETAIL m E ' MERCHANDISER ..y f ' 91 D j � t Z > >� M m I M1� 6�Op 0 Ld I Q SALE,M1 ?8 - - - ADJOINING �� ,,? , m S, 7 Lv . TENANT e3�OTy AREA T68� G -D SPACELlj �' [tl 28 2 48"V TABLE EXISTING VESBOULE ILI 928 928 21- < _ [ 4 i n z cc o Q _ OIn C� 0s EQUIPMENT PLAN- SCALE: 1/4" = 1'-0" f -J L I s NOTE: s� a � THESE DRAWINGS WERE COMPILED WITH THE MOST UP TO DATE DUNKIN' SPECS AS OF 05/30/14. ALL FURNITURE, FIXTURES ANDs � EQUIPMENT SHALL BE VERIFIED WITH OWNER AND D.B.I. C.M. JOB#: D1 60L' - BEFORE ORDERING, PURCHASING OR PLACING ANY ELEMENTS. DATE: 03! PCB: 33C7)CE C.M. V. L A � EQUIPMENT SCHEDULE v EQUIPMENT PLUMBING ELECTRICAL WATER WASTE LOAD N.S.F. U.L. SUPPLIED GENERAL REMARKS ITEM# QTy. DESCRIPTION MANUFACTURER MODEL# REMARKS #WIRES W/CORD RECEPT. A.F.F. REMARKSk x E.T.L. E.T.L. H.W. C.W. DIR. IND. VOLTS PHASE AMPS CIRCUIT W SPEC SIZE / &PLUG GROUND 10 SI NK STATION(BR)36"W x 31-1/2"D UNIVERSAL BR-36CBT-B31-2ES 2 1/2" 1/2" 1 1/2"-2' 11/2"OR 2"PER LOCAL CODE SINK BOWL IS 10"W x 18%x 20"D 106.1 4"FAUCET TO BE USED W/STANDARD 36"BR SINK COMPONENT HARDWARE KN41-4006 ** /2"NP 1/2"NPT MALE SHANKS **REG#A2601 ISO#9001 10D 14"x 24"WALL MOUNT SHELF FOR BR SI NK STATI ON METRO I NM1424BR 10G SILVERWARE SOU D SS CYLINDER VOLLRATH 78710 15A BANANATREE BUILT-IT 20045 -gin 15B HOT FUDGE WARMER W/I INSERTS,LI DS&PUMP SERVER PRODUCTS 82155 120 1 4.2 15 3 Y NEMA 5 15P **FILE E47076 15B.1 WARMER UNIT ONLY SERVER PRODUCTS FS 82500 120 1 4.2 15 Y NEMA 5-15P 15C HOT FUDGE/PRALINE CARAMEL/BUTTERSCOTCH WARMER INSERT SERVER PRODUCTS 94009 15D PARING KNIFE FOR CUTTING BANANAS DEXTER-RUSSELL S104 15E SCALE FOR MEASURING HAND-PACKED ICE CREAM OHAUS RE15US 120 1 600mA 15 3 Y NEMA 5-15P 15G SQUEEZE BOTTLE WARMER SERVER 86810 120 1 4.2 15 NEMA 5-15 20B DROP-IN ICE BIN CORNELIUS C2123 3/4" 20M BLENDING STATION-ADVANCE VITA-MIX 36011 120 1 15 20 NEMA 5-15 COUNTER-TOP BLENDER BLENDTEC CAl-4BQ-BR04 ** ** 120 1 15 20 NEMA 5-15 **NSF#29210-0001-000,UL#76320000 200 COUNTERTOP ADJUSTABEL CUP DISPENSER DISPENSE-RITE CTLD-22 23-1 99"Lx31-1/2"D BACKLINE WORKTOP REFRIGERATED BASE W/3 DOORS DELFIELD 18699BST 115 1 10 Y NEMA 5-15 23-2 93-1/4"Lx32-3/8"D BACKLINE WORK TOP REFRIGERATED BASE W/3 DOORS TRUE TWT-93 115 1 9.7 15 Y NEMA 5-15 24-1 60"Lx 31-1/2"D BACKLINE WORK TOP REFRIGERATED BASE W/2 DOORS DELFIELD ST446NO 115 1 12 15 Y NEMA 5-15 24-2 67-1/4"L x 32-2/8"D BACKLINE WORK TOP REFRIGERATED BASE W/2 DOORS TRUE TWT-67 115 1 5.1 15 NEMA5 15 � 30-1 27"W x 30-1/2"D SUNDAE STATION W/CASTERS SILVER KING SKF2A-C4 D025 165 9 115 1 4.6 15 3 NEMA 5 15 *30* 30-2 27-1/2"W x 30"D SUNDAE STATION W/CASTERS TRUE TSSU-27-8 115 1 4.6 15 Y NEMA 5-15 ` 30.1 SYRUP RAILS SERVER PRODUCTS SR-4-82830 tip 30H REFRIGERATED DAIRY AND SYRUP DISPENSE(BR CAPP BLAST-OPTIONAL) AC DISPENSING AC220PC „ ICE AND EASY RACKS AND CUPS.HOLDS MEASURED ICE SCOOPS FOR BR ICED 30 P WASSERSTROM 6012041 BEVERAGES 40 HAND SI NK-18"W x 30"D W/12"SPLASH GUARDS UNIVERSAL DD-18CBT32-RL D036264 1/2" 1/2" 1-1/2" COMPONENT HARDWARE FAUCETT&S#T5B1100 �f 40B TRASH RECEPTACLE-23 1/8"D x 11"W x 24 7/8"H RUBBERMAI D 3541 `= 41 HAND SINK-18"W x 36"D W/12"SPLASH GUARDS UNIVERSAL DD-18CBT36-RL D036264 1/2" 1/2" 1-1/2" . L i COMPONENT HARDWARE FAUCET T&S#TSB1100 42 HAND SINK 12"W x 36"D W/12"SPLASH GUARDS UNIVERSAL DD-12CBT32-RL D036264 1/2" 1/2" 1-1/2" COMPONENT HARDWARE FAUCET T&S#TSB1100 S I'4 r S 50D ACRYLIC CUP HOLDER-6 CUP LD PLASTICS LLDD36 50E ACRYLIC CUP HOLDER-8 CUP LD PLASTICS LLDD50 50F FOUR SECTION VERTICAL WIRE RACK CUP HOLDER DISPENSE-RITE WR-CT-4 # y, 60-1 DI PPI NG CABI NET-88 1/8"W x 29 3/4"D x 52 1/8"H W/CURVED GLASS GLOBAL CKDC 87 V-BR 1" CONDENSATE 115 1 11.5 15 4 Y NEMA 5 15 h 60.1 BASE FOR CKDC 87 V-BR DIPPING CABINET(UNFINISHED) SUPPLIER DWG# 60A DIPPERWELL BUILD-IT 9022 21-6 1/4" 1/2" 1 NDI RECT TO FLOOR DRAI IN 60B DI PPERWELL PAD BUILD-IT 9023 f _ 60Q Beverage Merchandiser.Used to merchandise the beverage cup sizes. Point View Displays,Inc. BR-01 j 61 1 DIPPING CABINET 67 1/8"W x 29 1/2"D x 52 1/8"H W/CURVED GLASS GLOBAL CKDC 67 V BR 1" CONDENSATE 115 1 8 15 4 Y NEMA 5-15 L� s F I 65A ICE CREAM&NOVELTY DISPLAY MERCHANDISER-40"W x 31"D x 50"H MASTERBI LT FI P-40 115 1 13.6 20 3 Y NEMA 5-20 65B ICE CREAM&NOVELTY DISPLAY MERCHANDISER-60"W x 31"D x 50"H MASTERBI LT FI P-50 115 1 13.4 15 3 Y NEMA 5-15 70R TISSUE BAG AND BOX HOLDER FOR DRIVE THRU RACK UNIVERSAL DD-DSPN71435 r 70.5B MOBILE DONUT/BAKERY CASE-6 TI ER X 3 WI DE VULCAN 1013776-000O164 120 1 20 fl� 70.5C MOBILE DONUT/BAKERY CASE-6 TI ER X 2 WIDE VULCAN 1015021-000O164 R EMOVAB LE TI SSU E BAG DISPENSER FOR LAKESIDE RACK(OPTIONAL) ,"* } 70.6 VULCAN 1013776E-P APPLIED TO FRONT OF RACK REMOVABLE TISSUE BAG AND BOX HOLDER(OPTIONAL)APPLIED TO SIDE OF V ..r96 70.7 RACK VULCAN 1014178 75 WARM BAKERY DISPLAY-FOR HESS LOCATIONS FEDERAL DD3870SS 120 1 2 15 Y NEMA5 15 � F4u t z 76 WARM BAKERY DISPLAY-FLOOR MODEL FEDERAL DD3876SS 120 1 2 15 Y NEMA 5-15 " 77 I NU NE BAKERY CASE FEDERAL DDI L5048 120 1 1.5 15 Y NEMA 5-15 I 78 DISPLAY RACK-18"x 24"SLANTED SHELVES(5 TIER) METRO DC16EC 1 81 SELF-SERVE DONUT CASE ROYSTON 10652 120 1 2 15 Y NEMA 5-15 _ 96 ESPRESSO MACHINE SCHAERER 15SO-PS-DD-40671 3/8" 11/2" 208 1 30 30 2W+1G Y NEMAL6-30 PROVI DE WATER SHUT-OFF VALVE W/3/8"COMPRESSION C;0 j FITTING W \ 96.1 ESPRESSO MACHINE-SINGLE SHOT SCHAERER E6 3/8" 11/2" 125 1 20 20 NEMA 5-20 SUPPLI ED W/SOFTENER/FI LTER/COMBO SYSTEM 96.2 ESPRESSO MACHINE WMF 03.9467.8400 1/2" 11/2" 220 1 30 30 Y NEMAL6-30 REQUI RES ADDITIONAL 15A 110-120V AC 5-15 R RECEPTACLE FOR Q COOLER C ��I 968 ESPRESSO SYRUP&LID RACK KIT WIREFAB WF17363 O 96J SWIRL/ESPRESSO AND COOLATTA SYRUP RACK WIREFAB WF31701 (/'� --- L--`- --. 101C-1 DAIRYDISPENSER-AUTOPORTION AC DISPENSING 320-FP-7 120 1 3 15 NEMA515 > �� 1010 SURE SHOT SUGAR DISPENSER AC DISPENSING AC6.E 120 1 2 15 NEMA 5-15 - ---- 101DD SUGAR BOWL VOLLRATH 69014 L1J 101E-1 FLAVOR SHOT DISPENSER AC DISPENSING AC-FS10 120 1 15 15 NEMA 5-15 � ✓- Cn 101E-3 FLAVOR SHOT DISPENSER-USED FOR CARTS AND APOD LOCATIONS AC DISPENSING AC-FS-5-5 120 1 15 15 NEMA 5 15 D {� 101F WIRE RACK COFFE CUP DISPENSER DISPENSE-RITE WRCT-4 C 101G SPEED RAIL FOR LIDS-20" MICROWIRE AD-HLDR-2 � �= ! 101H SUGAR/TEA BAG/STIRRER,HOLDER-13" MICROWIRE AD-SH-1 101M SPRAYER COMPONENT HARDWARE KN50-Y400-44 1/2" 11/2" 1 NDI RECT WASTE TO FLOOR DRAIN O 101N FLANGE FOR SPRAYER COMPONENT HARDWARE B-FK 101P-2 TWIN CARAFE BREWER CURTIS ALP4GT15A020 YES 20-90 PSI.MACHINE REQUIRES AI/4"MALE 220 1 34.5 50 Y NEMA14-50 FITTING 20-90 PSI.MACHINE REQUIRES A3/8"MALE BUNN PROVIDED CORD&PLUG INSTALLED 101P-3 AXIOM TWIN CARAFE BREWERW/CORD BUNN 38700.003 YES 208/120 1 33.3 50 3w+1G Y NEMA14-50 BY GENERAL CONTRACTOR FITTING � f 20-90 PSI.MACHINE REQUIRES A 1/4"MALE 101PP-2 SINGLE CARAFE BREWER CURTIS ALP2GT15A020 YES 220 1 16.8 20 Y NEMA L14-20 FITTING 101PP-3 AXION SI NGLE CARAFE BREWER W/CORD BUNN-O-MATIC 38700.0031 YES 20-90 PSI.MACHINE REQUIRES A 1/4"MALE 208/120 1 16.7 20 3w+lG Y NEMA L14-20 BUNN PROVIDED CORD&PLUG INSTALLED FITTING BY GENERAL CONTRACTOR MULTI HOPPER GRINDER AND STORAGE SYSTEM-USED WITH AXIOM BUNN PROVIDED CORD&PLUG INSTALLED 101Q 3 BUNN O MATIC 35600.0011 120 1 11 15 2 Y NEMA5-15 BREWERS BY GENERAL CONTRACTOR � I 102A FLAVOR SHOT 9 PUMP COUNTERTOP RACK WIREFAB WF30563 20-90 PSI FROM A 3/8"OR LARGER SUPPLY BUNN PROVIDED CORD&PLUG INSTALLED 107A DUNKACCI NO MACHINE BUNN-O-MATIC 29250.0003 18 197 3/8' LINE.ASHUT OFF VALVE SHOULD BE INSTALLED 208/120 1 17 20 3 NEMALI4-20 -' - IN TH E LI NE BEFORE TH E UNIT BY GENERAL CONTRACTOR BUNN PROVIDED CORD&PLUG INSTALLED ~108-A1 HOT WINTER BEVERAGE MACHINE BUNN O MATIC DDHWB 1/4 20-90 PSI(138-621 KPA) 208/120 1 21.7 30 3w+1G Y II 1, E( 108A* BYGENERAL CONTRACTOR 108-A2 HOT WINTER BEVERAGE MACHINE CECILWARE GB5M5.5-IT-U-DB 1/4" MIN.30 PSI AWTER INLET PRESSURE 208/240 1 28.8 30 NEMAL14-30PNO WATER HOOK-UPS FOR AIR COOLED (2)NEMA L6 (2)208/230 CIRCUITS FOR EACH MACHINE; 7- - 110 COOLATTA MACHINE FLOOR MODEL,2 HEAD DISPENSER TAYLOR FREEZER 342 6 SA 4620 MODELS;1/2"FPTCONNECTION FOR WATER 208-230 1 19/14 20/20 3 Y 20 VERIFY CORD&PLUG W/MANUFACTURER; -- P ( ) I t..:+ i ALTERNATIVEELEC.CONFIGSAVAILABLE. U e___ `� (' COOLED,TO FLOOR DRAIN 1 NO WATER HOOK-UPS FOR AIR COOLED CORD&PLUG NOT AUTOMATICALLY p •. < 111 COOLATTA MACHINE-COUNTER MODEL,120 SERVINGS PER HOUR TAYLOR FREEZER 340 6 SA 4620 MODELS;1/2"FPT CONNECTION FOR WATER- 208-230 1 16 20 3 Y NEMA L6-20 SUPPLIED W/UNIT;ALTERNATE ELEC -j /� COOLED,TO FLOOR DRAIN CONFIGS AVAILABLE m / Q NO WATER HOOK-UPS FOR AIR COOLED CORD&PLUG NOT AUTOMATICALLY i a - 112 COOLATTA MACHINE-COUNTER MODEL,60 SERVINGS PER HOUR TAYLOR FREEZER 430 6 SA 4620 MODELS;1/2"FPT CONNECTION FOR WATER- 115 1 16 20 2W+lG Y NEMA 5-20 SUPPLIED W/UNIT;ALTERNATE ELEC `� I Do 114 COOLATTASYRUPRACK WIREFAB WF22926 COOLED,TO FLOOR DRAIN �{ '_j ` CON 1/4"ID-3/8"OD QUICK CONNECT t 116 BLENDER/ISLAND OASIS MAGNABLEND SB2512-WDD HOSE/FITTING 110 1 5.3 60 Hz 110 1 0.8 LLJ 60 Hz 120E-1 UNDERCOUNTER REFRIGERATOR-27"W/CASTERS,RIGHT HINGE DELFI ELD 406-CA-SPL-RHH 7 SA 4769 115 1 7 15 3 Y NEMA 5-15 RIGHT HAND HINGE ( ` *120F 120E-2 UNDERCOUNTER DELFIELD 406-CA-SPL-LHH 7 SA 4769 115 1 7 15 3 Y NEMA5-15 LEFT HAND HINGE * I j 120E-3 UNDERCOUNTER REFRIGERATOR-27"W/CASTERS,LEFT HINGE VICTORY UR-27-SST 115 1 5.6 15 2 Y NEMA 5-15 DOOR CAN BE RE-HINGED IN FIELD 126 SOFT SERVE FREEZER-USED IN BR&DD/BR LOCATIONS TAYLOR FREEZER C709 208-230 1 24 30 3 NEMA 6-30 126B VITA MIX SOFT SERVE ICE CREAM MIXER VITA MIX VM0800A 120 1 1.5 20 NEMA 5-15 126C CUP HOLDER USED W/BR SOFT SERVE PROGRAM-3 CUP SIZES DISPENSE-RITE WR-CT-3 126D U D HOLDER USED W/BR SOFT SERVE PROGRAM-3 LI D SIZES DISPENSE-RITE WR-3 129E CART FOR SOFT SERVE ICE CREAM MACHI NE TAYLOR FREEZER C20100-000 -- -- ~ 130 DONUT/BAKERY RACK AT DRIVE THRU-35"W x 28"D UNIVERSAL DD 36SLC-29 RK C Si 140A DOME LID DISPENSER DISPENSE-RITE WR-4 :' ** 20-90 PSI MACHINE SUPPLIED WITH 1/4"O.D. 6'CORD TO BE PROVIDED&INSTALLED BY 200A ICED COFFEE BREWER-#IC3DDW/CORD BUNN-O-MATIC 24450.0003 1/2" MALE FLARE FITTING 120 1 19.5 30 3W+1G N NEMALI4-30 GC **E34066 1 201A ICECADDY CAMBRO ICS100L 201E ICED COFFEE DISPENSER-INCLUDES HOUSI NG&(2)RESERVOIRS BUNN-O-MATIC 35100 , 202A ICED COFFEE DISPENSER CABINET BUNN ICDD-3 - 210c- JOB#: D1 �'0 BAGELTOASTER HATCO TQ-20BA208.DNK 208 1 15.8 Y NEMA *zloc 1 DATL: 0�f * 21OC 2 BAGELTOASTER BELLECO JT2-B 4 356E 208 1 15.4 Y NEMA L6-20 ALSOAVAILABLE240/60/1PH/13.8AMP W/NEMAL6-20P PLUG P C r r� C.h✓1. V. ell EQUIPMENT SCHEDULE CD EQUIPMENT PLUMBING ELECTRICAL .w. WATER WASTE LOAD SUPPLIED GENERAL REMARKS N.S.F. U.L. RECEPT. ITEM# QTY. DESCRIPTION MANUFACTURER MODEL# REMARKS #WIRES W/CORD A.F.F. REMARKS E.T.L. E.T.L. H.W. C.W. DIR. IND. VOLTS PHASE AMPS CIRCUIT W/ &PLUG SPEC SIZE GROUND 210D BAGEL SLICER PRINCE CASTLE 970-DD 201D.1 CRUMB CATCHER PRI NCE CASTLE 970-097 212A-1 WARMING UNIT-(2)TIER MODULAR HOLDING CABINET FOR NGSS CARTER HOFFMAN MC3W2SN01 120 1 10 3 Y NEMA 5-15 ' DEDICATED HOLDING BIN-27"W x 14"D x 11"H,CAPACITY OF UP TO(6) 212A-2 1/3 SIZE PANS PRINCE CASTLE DHB2SS-27BDD 120 1 10 NEMA 5-20 212A 3 (2)TIER MODULAR HOLDING CABINET-23 7/8"W x 14 11/16"D x 12 1/2"H' CARTER HOFFMAN MC212 DD 120 1 15 3 NEMA 5 15 CAPACITY OF UP TO(6)1/3 SIZED PANS-(DEFAULT) _ 212A.1 WARMING UNIT FOR APODS CARTER HOFFMAN MC1W2S { 214-2 OVERSHELF,64%x 21 1/2"D,REFRIGERATOR MOUNT FOR TOASTER& DELFIELD 000-B3P 021U PACKAGING TORNADO OVEN W/STONE,PEEL AND(2)TRAYS-EXTENDED WARRANTY f x 215 INCLUDED TURBOCHEF NGC-1180-1-2019 208 1 30 30 Y NEMA 6-30 215A STAINLESS STEEL CART 28"W x 30"L x 17"H REINFORCED TO HOLD(2)TURBO CHEF OVENS UNIVERSAL DD 30SLS 3017 C 216 MULTI-STAGING WARMER FOR HASHBROWNS HATCO GRMW-3DD 120 1 1 5.9 15 Y NEMA 5-15 217 SANDWICH STATION TABLE FOR NGSS-16"W x 30"D UNIVERSAL DD-16SLC-30 212A.2 32"REFRIGERATED WORKTOP W/(2)DRAWERS AND(1)TOP OPENING FOR DELFIELD UCD4432N 6 DD1 115 1 6.5 15 Y NEMA5 15 PRODUCT PANS-USED FOR NGSS 48"BREAKFAST WORKSTATION-USED FOR KIOSKS AND NGSS I N SMALLER 226 SPACES DELFIELD UCD4448N-6M-DD2 115 1 12 15 Y NEMA 5-15 �a2 � 32"BREAKFAST WORKSTATION(CUSTOM)LEFT 51DE REFRIGERATION UNIT 230 W/COLD WELL DELFIELD DDBWS-32 115 1 6.5 15 Y NEMA 5-15 232 OVERSHELF FOR 48"BREAKFAST STATION DELFIELD TBD a 239 48"UNDERCOUNTER REFRIGERATOR DELFIELD UCD4448N-6M-DD2 115 1 6.5 15 Y NEMA 5-15 242-1 33"COOK STATION DELFIELD DBCS33 ` 242-2 32"COOK STATION DUKE DD32COOK , 2 244A 20"WIDE I NTELLI GENT TOAST-QWI K HATCO ITQ-1750-2C ' = 1) i45A 27"WIDE TOASTER STATION DELFIELD DBTS27 d .k,, C, ; 2456- 40"WIDE TOASTER STATION-FOR LEFT OR RIGHT FLOW LAYOUT DELFIELD DBTS40 LI f O C i 245C 27"WIDE DUKE TOASTING STATION DUKE DD27TOAST 1 �T n y i 245D1 40"WIDE DUKE TOASTING STATION LEFT TO RIGHT FLOW DUKE DD40TOASTR2L 40"WI DE DUKE TOASTI NG STATION RIGHT TO LEFT FLOW DUKE DD40TOASTL2R ;, ' 246A-1 SINGLE SIDED HOT HOLDING CABI NETS CARTER HOFFMAN MZ343S-DD 246A-2 12 BAY SI NGLE SI DE HOT HOLDI NG CABI NET PRI NCE CASTLE DHB3PT-33DD 246E-1 PASS THRU HOT HOLDING CABINET CARTER HOFFMAN MZ343P-DD 247-1 3 3"ASSEMBLER STATION-LEFT OR RIGHT FLOW LAYOUT DELFI ELD DBAS33 247-2 32"ASSEMBLY AND 12"EXPEDITOR STATION DUKE DD32ASSEMBLY 248-1 40"ASSEMBLER STATION-LEFT OR RIGHT FLOW LAYOUT DELFIELD DBAS40 E`L, 38"ASSEMBLY STATION-RIGHTTO LEFT DUKE DD38ASSEMBLY-R2L 248-2 38"ASSEMBLY STATI0N-LEFT TO RIGHT DUKE DD38ASSEMBLY-L2R 249 18"Wx36"Dx34"H TABLE-PLACEHOLDER FOR FUTURE MENU METRO DBCT1836 249-1 18"WIDE EXPEDITER STATION DELFIELD DBES18 249-2 18"WIDE EXPEDI TE TABLE DUKE DD18EXPEDITE F., ✓ 250 �' L� 251 280-1 UPRIGHT FREEZER-(1)SECTION CAKE&QUART DISPLAY GLOBAL ULG30BSP 115 1 14.6 20 Y NEMA 5-20 1 SECTION CAKE&QUART DISPLAY ¢ 4 *280* (1)GLASS DOOR MERCHANDISER-SHOWN IN SALES AREA-31"W x 36 280-2 MASTERBILT BLG-27HD 115 1 13.9 20 3 Y NEMA 5-20 1 SECTION CAKE&QUART DISPLAY x 3/4"D x 79"H 281-1 UPRIGHT FREEZER-(2)SECTION CAKE&QUART DISPLAY GLOBAL ULG50BCP 115 1 13 20 Y NEMA L14-20 2 SECTION CAKE&QUART DISPLAY . *281* (2)GLASS DOOR MERCHANDISER-SHOWN IN SALES AREA-56"W x 36 281-2 3/4"D x 79"H MASTERBILT BLG-52HD 208-230 1 10.6 20 4 Y NEMA L14-20 2 SECTION CAKE&QUART DISPLAY 282-1 UPRIGHT FREEZER-(3)SECTION CAKE&QUART DISPLAY GLOBAL ULG80BCP 115 1 16 20 Y NEMA L14-20 3 SECTION CAKE&QUART DISPLAY *282* (3)GLASS DOOR MERCHANDISER-SHOWN IN SALES AREA-84"W x 36 282-2 MASTERBILT BLG 80HD 208 230 1 11.1 20 4 Y NEMA L14 20 3 SECTION CAKE&QUART DISPLAY ----- -----~ --°~ 3/4"D x 79"H 395 HAND WASHING SINK W/SIDE SPLASHES-FOR FRONT&BACK ROOM UNIVERSAL EHS-IRL-WH 1/2" 1/2" 1 1/2" 1 1/2"-2"PER LOCAL CODE I cG 402 EMPLOYEE LOCKER WIN-HOLT WL-66(156195) \' 414 1000 LB CUBE ICE MACHINE SCOTSMAN C1030 f` LO e 419 STORE ROOM WIRE SHELVING METRO VARIES 420A SHELF-24"W x 60"D-ORDER(5)SHELVES PER UNIT METRO 2460BR O 420E SHELF-24"W x 48"D-ORDER(5)SHELVES PER UNIT METRO 2448BR 420C SHELF-24"W x 36"D-ORDER(5)SHELVES PER UNIT METRO 2436BR m 420D SHELF-24"W x 24"D-ORDER(5)SHELVES PER UNIT METRO 2424BR z L i 421A SHELF-18"W x 60"D-ORDER(5)SHELVES PER UNIT METRO 1860BR .� O 421E SHELF-18"W x 48"D-ORDER(5)SHELVES PER UNIT METRO 1848BR 1— 421C SHELF-18"W x 36"D-ORDER(5)SHELVES PER UNIT METRO 1836BR STAI NLESS STEEL WI RE DRYING CART 18"x 36",TO BE USED I N LOCATIONS (� Q I 421H METRO 2SPN33AS Li.l i THAT DO NOT HAVE(2)DRAI N BOARDS ON THE THREE COMPARTMENT SINK z ) I I — j 90"W X 23 3/4"D THREE COMPARTMENT SINK-12"W x 20"D BOWL W/(2) DD-3N1818142D18S/TSB- DI R/I ND WASTE AS DETERMINED BY S.S.TOP,SPLASHES ON(3)SIDES. T&S PRE RINSE O 424 12"W DRAIN BOARD. (3)TWIST HANDLE LEVEL DRAINS UNIVERSAL 133-B/TSB-156 3/4" 3/4' 2 LOCALCODES WALL UNIT(INCLUDES BRACKET)W/ADDAFAUCET .'' 12"SPOUT TO SHIP W/3 BAY SINK 64"W X 27"D THREE COMPARTMENT SI NK-12"W x 20"D BOWL W/(2) BR-MS3N1220-2D12/TSB- DI R/I ND WASTE AS DETERMINED BY S.S.TOP,SPLASHES ON(3)SI DES. T&S PRE-RI NSE 428A 12"W DRAIN BOARD. (3)TWIST HANDLE LEVEL DRAINS UNIVERSAL 133 B/TSB 156 3/4 3/4' 2 LOCALCODES WALL UNIT(INCLUDES BRACKET)W/ADD-A-FAUCET 12"SPOUT TO SHIP W/3 BAY SINK 430 SINGLE SECTION REACH-IN REFRIGERATOR,FULLHEIGHT-LEFTHINGEDOOR DELFIELD MRR1-S 115 1 8.5 15 Y NEMA 5-15 i 64"W X 27"D THREE COMPARTMENT SI NK(FRONT SKIRT)-12"W x 20"D BR-MS3N1220-2D12S/TSB- DI R/I ND WASTE AS DETERMI NED BY S.S.TOP,SPLASHES ON(3)SI DES. T&S PRE-RI NSE 430A BOWL W/(2)12"W DRAIN BOARD. (3)TWIST HANDLE LEVEL DRAINS UNIVERSAL 133-B/TSB-156 3/4" 3/4" 2° LOCALCODES WALL UNIT(INCLUDES BRACKET)W/ADD A FAUCET 12"SPOUT TO SHIP W/3 BAY SINK 431 TWO SECTION REACH-IN REFRIGERATOR/FREEZER,FULL HEIGHT-LEFT DOOR DELFIELD MD1R2S 115 1 11.1 15 Y NEMA515 REFRIGERATOR,RIGHT DOOR FREEZER I 112"W X 34"D THREE COMPARTMENT SI NK(JUST BAKED)-20"W x 28"D x DD-3 N202814-2D24/TSB- DI R/I ND WASTE AS DETERMI NED BY S.S.TOP,SPLASHES ON(3)SI DES. T&S PRE-RI NSE Q 1 -_ 434A UNIVERSAL 3/4" 3/4" 2" WALL UNIT(INCLUDES BRACKET)W/ADD-A-FAUCET � O 14'BOWL W/(2)24"W DRAIN BOARD. (3)TWIST HANDLE LEVEL DRAINS 133-B/TSB-158 LOCALCODES 12"SPOUTTO SHIP W/3 BAY SINK 0 90"SINK TRAX SHELVING WORKSTATION-INCLUDES SHELVING&BRACKETS F- t 435A ISS WST1435E (USED FOR 64 &90 THREE COMPARTMENT SINK) Q _� ✓ I 108"SINK TRAX SHELVING WORKSTATION-INCLUDES SHELVI NG& O 4356 ISS WST1415E I BRACKETS(USED FOR 112 THREE COMPARTMENT SINK) < (�p,�^ 450C BR CAKE PHOTO SCANNER/PRI NTER BAKERY CRAFT BCC-1ABR E140 858 110 1 1 15 3 Y yy/GROUND O LLJI 450H TUB CUTTER BUILD-IT 20030 ' 450M (5)QUART STAND MIXER FOR BR(COLOR-WHITE) KITCHENAID KV25GOXWW 115 1 C __ 451 60"W x 31"D D BR CAKE PREP TABLE WITH STAINLESS STEELTOP UNIVERSAL BR-60SLC-31 452 72"W x 31"D D BR CAKE PREP TABLE WITH STAINLESS STEELTOP UNIVERSAL BR-72SLC-31 455 24"D x 36%STAI NLESS STEEL TABLE W/DOUBLE OVERSHELVES UNIVERSAL 35LCB-24/COS-DBL-3608 L-Li 460-1 HARDENING CABINET-SINGLE DOOR,HINGED LEFT MASTERBILT I HC-27 1 208-230 7.4 15 3 Y NEMA 6-15 *460* 460-2 HARDENING CABINET-(1)SECTION,(2.5)DOORS GLOBAL T30HSP 115 1 11.5 15 Y NEMA 5-15 HARDEN NG CABI NET-(2)DOOR,(2)SECTI ON-LEFT DOOR HI NGED LEFT, *461* 461-1 RIGHT DOOR HINGED RIGHT MASTERBILT IHC-48 208-230 11.5 15 3 Y NEMA 6-15 461-2 HARDENING CABI NET-(2)SECTI ON,(2.5)DOORS GLOBAL T50HSP 115 1 11.5 15 Y NEMA5-15 ' S.S WORKTABLE-36"x 30"W/BACKSPLASH.FIXED S.S.UNDERSHELF(TABLE 462 ONLY) UNIVERSAL 3SLSB-30 r 462A S.S WORKTABLE-36"x 30"W/BACKSPLASH.FIXED S.S.UNDERSHELF UNIVERSAL DD-3SLSB-30-OSC12 S.S.WORKTABLE-48"X30"W/BACKSPLASH.FIXED S.S.UNDERSHELF(TABLE S H E FT 463 ONLY) UNIVERSAL 4SLSB-30 " 463A S.S.WORKTABLE-48"X30"W/BACKSPLASH.FIXED S.S.UNDERSHELF UNIVERSAL DD-4SLSB-30-OSC12 , a � S.S.WORKTABLE-60"X30"W/BACKSPLASH.FIXED S.S.UNDERSHELF(TABLE ry 464 ONLY) UNIVERSAL SSLSB-30 464A S.S.WORKTABLE-60"X30"W/BACKSPLASH.FIXED S.S.UNDERSHELF UNIVERSAL DD-SSLSB-30-OSC12 470 ICE MACHINE-PRODUCES UP TO 255 LBS OF ICE PER 24 HRS,AIR COOLED MANITOWAC IY 0324A YES YES 3/8" 3/4" DI R/I ND WASTE PER LOCAL CODE 115 1 11.5 15 N *WATER COOLED 10.7A;208-230/60/1 PRODUCES 255 LEIS OF ICE IN 24 HOURS.THIS UNIT JOB#: D 16 0 0`4- 22"WIDE AND 230/50/1 ALSO AVAILABLE NEEDS TO BE HARD WIRED BY AN ELECTRICIAN - ICE MACHINE-PRODUCES UP TO 255 LBS OF ICE PER 24 HRS,AIR COOLED- *WATER COOLED 10.oA;208-230/60/1 PRODUCES 255 LBS OF ICE IN 24 HOURS.THIS UNIT DATE: 0 3/1 5 471 30"WIDE MANITOWAC IY 0304A YES YES 3/8" 1/2" DIR/IND WASTE PER LOCAL CODE 115 1 10.8 15 N AND 230/50/1 ALSO AVAILABLE NEEDS TO BE HARD WIRED BY AN ELECTRICIAN PC#: 33036( EQUIPMENT SCHEDULE EQUIPMENT PLUMBING ELECTRICAL WATER WASTE LOAD SUPPLIED GENERAL REMARKS N.S.F. U.L. RECEPT. ITEM# QTY. DESCRIPTION MANUFACTURER MODEL# REMARKS #WIRES W/CORD A.F.F. REMARKS E.T.L. E.T.L. H.W. C.W. DIR. IND. VOLTS PHASE AMPS CIRCUIT W/ &PLUG SPEC µ SIZE GROUND 472 ICE MACHINE-PRODUCES UP TO 450 LBS OF ICE PER 24 HRS,AIR COOLED *WATER COOLED 13.5A;208-230/60/1 PRODUCES 450 LBS OF ICE IN 24 HOURS.THIS UNIT m 22"WIDE MANITOWAC IY 0524A YES YES 3/8 1/2" DIR/IND WASTE PER LOCAL CODE 115 1 20 20 N AND 230/50/1 ALSO AVAILABLE NEEDS TO BE HARD WIRED BY AN ELECTRICIAN ICE MACHINE-PRODUCES UP TO 670 LBS OF ICE PER 24 HRS,AIR COOLED- *WATER COOLED 10.9A;208-230/60/1 PRODUCES 670 LBS OF ICE IN 24 HOURS.THIS UNIT 473 MANITOWAC IY-0854A YES YES 3/8" 1/2" DIR/IND WASTE PER LOCAL CODE 208-230 1 11.9 20 N 30 WIDE AN D 23 0/5 0/1 ALSO AVAI LAB L E NEEDS TO BE HARD WIRED BY AN ELECTRICIAN ICE MACHINE-PRODUCES UP TO 850 LBS OF ICE PER 24 HRS,AIR COOLED- *WATER COOLED 9.7A,208-230/60/1 AND PRODUCES 850 LBS OF ICE IN 24 HOURS.THIS UNIT k 474 30"WIDE MANITOWAC IY-1004A YES YES 3/8" 1/2" DIR/IND WASTE PER LOCAL CODE 208-230 1 13.5 20 N 230/50/1 ALSO AVAILABLE NEEDSTO BE HARD WIRED BYAN ELECTRICIAN 475A ICE BIN-310 LB CAPACITY MANITOWAC B420 *475* 475B ICE BIN-150 LB CAPACITY MANITOWAC B170 475C ICE BIN-430 LB CAPACITY MANITOWAC B570 J 475D ICE BIN-710 LB CAPACITY MANITOWAC B970 -_-• - INCANDESCENT DOOR LIGHT/HEATER-115V, UTILITYINFOSHOWNIS FOR INDOOR UNIT­VERIFY ALL INFOFOR 480-1 WALK-IN COOLER/FREEZER PACKAGE NORLAKE PER WALK-IN ORDER FORM ** PROVIDE DRAIN FOR EVAPORATOR COIL ** ** ** ** ** 5A,iPH;FL LIGHTS(EACH)-115V,1PH; CONDENSATE(HEATED IF LOCATED OUTDOORS) N HTD/AIR VENT-115V,2A,1PH;FREEZER OUTDOOR UNITS;IF CONTROL WIRES REQUIRE EXTENSION,IT IS *480* THE RESPONSIBILITY OF THE GC TO RUN THE WIRING SYSTEM-208-230V,17A,3PH PROVIDE DRAIN FOR EVAPORATOR COIL UTILITY INFO SHOWN IS FOR INDOOR UNIT-VERIFYALL INFO FOR I 480-2 WALK-IN COOLER/FREEZER PACKAGE KOLPAK PER WALK-IN ORDER FORM ** ** ** ** ** ** ( ` CONDENSATE(HEATED IF LOCATED OUTDOORS) N OUTDOOR UNITS;IF CONTROL WIRES REQUIRE EXTENSION,IT IS THE RESPONSIBILITY OF THE GC TO RUN THE WIRING u 487 UNDERCOUNTER ICE MACHINE HOSHIZAKI AMERICA KNM-251BAH YES YES 1/2" 3/4" DIR/IND WASTE PER LOCALCODE 115 1 9 15 NEMA S 15 PROVIDES 251 LBS OF ICE PER 24 HOURS -N r- 489 ICE MACHI NE-PRODUCES UP TO 155 LBS OF ICE PER 24 HOURS MANITOWAC SY-0214A YES YES 3/8" 3/4" DI R/I ND WASTE PER LOCAL CODE 115 1 7.8 15 NEMA 5-15 POWER CORD ONLY,NO PLUG ALSO AVAILABLE IN 208-230/60/1 490E Soo MIXER-140 CIT HOBART HL1400 200-240 3 14.8 NO NEMA 15-15 510 FLOOR SCALE DETECTO 4570 510C FRYER,WITH BUILT-IN FILTER AND FRY QUALITY MONITOR PITCO FRIALATOR DD 24RUFM t> 511 MANUAL DONUT DEPOSITOR W/ADJUSTABLE ARM BELSHAW TYPE'B' L. 512 GLAZER-SEMI-AUTOMATED BELSHAW HG24-EZ/DD 513 GLAZER-MANUAL BELSHAW HG24-W/DD r� �, u **1/2"NPFT PIPE(MIN),30-80 PSI 2 95" •* ** ** ** 240V,31-35A,1PH,NEMA14-50R; i* _� 520 EQDPROOFER(208V) BAXTER PC151DD-1 907 1/2" A.F.F.;REAR DRAINAT5"A.F•F•,ROUTETOAIR 40/15 3EA Y (2)ELECTRICALCONNECTIONSREQUIRED;MIN.CEILINGHEIGHT �- GAP DRAIN CONTROL CIRCUIT:120V,5A,1 PH,NEMAS- OF 102"A.F.F.IS REQUIRED. ; 520D EQD SINGLE HEAD WATER FILTER#QC71 HEAD ONLY EVERPURE 9272-41 3/8° FOR#520 WILL SERVICE UP TO 3 PROOFERS `3 523 EQD WATER CHILLER#SC340 MULTIPLEX SS901130 18 ** 1/2" 230 1 11.9 15 16/3 SO Y NEMA6-15 **ETL REPORT#99004330.004 ` j 1 U N I VERSAL OVEN-NATURAL GAS.USED FOR BAKI NG ALL PRODUCTS. 1/2"REAR DRAIN TOAIR GAP DRAIN;3/4"NPT 535-1 CAPACITY:5 SHEET PANS;18"X26"OR 6 MUFFI N PANS,20 CUP BAXTER OV30OG-SEFDDE 1/2" 1/2 GAS CONNECTION;G.C.TO FURNISH AND 120 1 6.6 15 Y NEMA 5-15 _ �, F>wCL INSTALL WATER FILTER *;. - UNIVERSAL OVEN-ELECTRIC 208V.USED FOR BAKI NG ALL PRODUCTS. „ „ 1/2"REAR DRAIN TO AIR GAP DRAIN;G.C.TO 1-120/60/1/15A DEDICATED CIRCUIT REQUIRED FOR '1 „535-2 CAPACITY:5 SHEET PANS;18"X26'OR 6 MUFFI N PANS,20 CUP.VOLTAGE BAXTER OV300E-SEFDDE 1/2 1/2 120 3 50 60 Y NEMA 15-50 , FURNISH AND INSTALL WATER FILTER A NEMA 5-15 CORD. s SPECIFIED ON EQUIPMENT DATA FORM *535* UNIVERSAL OVEN-ELECTRIC 240V.USED FOR BAKING ALL PRODUCTS. 535-3 CAPACITY:5 SHEET PANS;18"X26"OR 6 MUFFIN PANS,20 CUP.VOLTAGE BAXTER OV300E-SEFDDF 1/2" 1/2" 1/2"REAR DRAIN TOAIR GAP DRAIN;G.C.TO 120 3 43 50 Y NEMA 15-50 1-120/60/1/15A DEDICATED CIRCUIT REQUI RED FOR FURNISH AND INSTALL WATER FILTER SPECI FI ED ON EQUI PMENT DATA FORM A NEMA 5-15 CORD. I, UNIVERSAL OVEN-PROPANE.USED FOR BAKING ALL PRODUCTS.CAPACITY: 1/2"REAR DRAIN TO AIR GAP DRAIN;3/4"NPT 535-4 5 SHEET PANS;18"X26"OR 6 MUFFIN PANS,20 CUP. BAXTER OV30OG-SEFDDF 1/2" 1/2" GAS CONNECTION;G.C.TO FURNISH AND 120 1 6.6 15 Y NEMA 5-15 W ••--- -�' INSTALL WATER FILTER 538-1 MINI-ROTATING RACK BAKERY OVEN-ELECTRIC BLODGETT XR8-E 3/4" 3/4" 208-240 3 50/45 50 NEMA 15-50 1-120/60/1PH 15ACIRCUIT REQUIRED FOR *538* DEDICATED CONTROL CORDmi,*t h 538-2 MINI-ROTATING RACK BAKERY OVEN-GAS BLODGETT XR8-G 3/4" 3/4" 3/4"NPT GAS SUPPLY 120 1 15 15 NEMA 5-15 208 38/38/38 240 36/34/34 539A 1 HYDROVECTION SINGLE DOOR-ELECTRIC BLODGETF HV-100E SINGLE 3/4 1" 2.5-3.0 GALLONS PER MINUTE 3 50 60 Hz 440 20/18/18 r 480 18/17/17 '} 3/4" I NLET PRESSURE-NATURAL GAS AT 7.0"W.C.STATI C 539A-2 HYDROVECTION SINGLE DOOR-GAS BLODGETT HV-10OG SINGLE 1" 2.5-3.0 GALLONS PER MINUTE TO UNIT a"bF� y, I NLET PRESSURE-PROPANE GAS AT 14.0"W.C.STATIC "y TO UNIT" 208 38/38/38 240 36/34/34 --.•�.-- -_.. 5396-1 HYDROVECTION DOUBLE DOOR-ELECTRIC BLODGETT HV-100E DOUBLE 3/4" 1" 2.5-3.0 GALLONS PER MINUTE 440 3 36/34/34 50 60 Hz 480 18 18/17/17 LLJ INLET PRESSURE-NATURAL GAS AT 7.0"W.C.STATIC Q In 5396-2 HYDROVECTION DOUBLE DOOR-GAS BLODGETT HV-100G DOUBLE 3/4" 1" 2.5-3.0 GALLONS PER MINUTE TO UNIT INLET PRESSURE-PROPANE GAS AT 14.0"W.C.STATIC 0 TO UNIT �f) 540 MAPLE CUTTING TOP JOHN BOOS Z �- c 541-A DUNNAGE RACK-36"W x 20"D,SI NGLE TI ER,USED FOR JUST BAKED LOCKWOOD D2036-8 C� 541-B DUNNAGE RACK-48"W x 20"D,SI NGLE TI ER,USED FOR JUST BAKED LOCKWOOD D2048-8 *541* 541-C DUNNAGE RACK-60"W x 20"D,SI NGLE TI ER,USED FOR JUST BAKED LOCKWOOD D2060-8 > O � 541-D DUNNAGE RACK-72"W x 20"D,SI NGLE TI ER,USED FOR JUST BAKED LOCKWOOD D2072-8 � Fz 541-E DUNNAGE RACK-32"W x 20"D,SI NGLE TI ER,USED FOR JUST BAKED LOCKWOOD D2032-8 J 543 BAKERY PAN RACK KELMAX APRU1618-4-AT-BK-MOD (� `—�� PROVIDE PRESSURE REDUCING VALVE, Lli 552-A FRESH BAKED SI NGLE CONVECTION OVEN W/STAND ADAMATIC BELSHAW BX-DD-S 3/4" PRESSURE GAUGE&SHUTOFF VALVE AT 208-220 3 20.8-22.3 30 4 Y L15-30 2 SEPARATE CIRCUITS REQUIRED ALSO REQUIRES(1)120V/60H/1PH/15ANEMAS 15 PLUMBING CONNECTION TO OVEN DEDICATED CIRCUIT O -- 552 PROVIDE PRESSURE REDUCING VALVE, 552-B FRESH BAKED DOUBLE CONVECTION OVEN W/STAND ADAMATIC BELSHAW BX-DD-D 3/4" PRESSURE GAUGE&SHUTOFF VALVE AT 208-220 3 20.8-22.3 30 4 Y L15-30 2 SEPARATE CIRCUITS REQUIRED PER ALSO REQUIRES(1)120V/60H/1PH/15A NEMA 5-15 �d, PLUMBING CONNECTION TO OVEN OVEN DEDICATED CIRCUIT PER OVEN 554 GLAZER WITH EZ ROLL APPLICATOR-USED FOR JBOD BELSHAW 22338HG-18EZDD-34 554A GLAZER WITH EZ ROLL APPLICATOR-USED FOR JBOD BELSHAW 22338HG-18EZDD-32 *554* 554B GLAZER WITH SCOOP HOLDER-USED FOR JBOD BELSHAW 22338HG-18DD34 554C GLAZER WITH SCOOP HOLDER-USED FOR JBOD BELSHAW 22338HG-18DD32 s 4 554E 18"x26"X3.5"DEEP TRANSLUCENT FOOD BOX.GLAZING SMALLWARES CAMBRO 18263CW 560 48"X36"STAINLESS STEEL FINISHING TABLE W/10"OVERSHELF UNIVERSAL DD-4SLCB36-OS2ES L I 560.1 FLAT 14"X60"SOLID SHELVING METRO 1460FG 560.2 SINGLE DIRECTWALL MOUNT BRACKET METRO 1WD14C *560* 560.3 DOUBLE DI RECT WALL MOUNT BRACKET METRO 2 WD14C 560.4 FLAT 14"X48"SOLID SHELVING METRO 1448FG .r 560A 96"X36"STAINLESS STEEL FINISHING TABLE W/10"DEEP OVERSHELF UNIVERSAL DD-8SLCB36-OS2ES Z *560* 5606 72"X36"STAINLESS STEEL FINISHING TABLE W/10"DEEP OVERSHELF UNIVERSAL DD-6SLCB36-OS2ES 0 560C 36"X60"STAINLESS STEEL FINISHING TABLE W/10"DEEP OVERSHELF UNIVERSAL DD-5SLCB36-0S2ES Q ) 561 FINISHED PRODUCT RACK(IN SHOP USE ONLY-NOT ENCLOSED) KELMAX APRUE1326-5/AT/TG/BK `` , 562 TOPPINGS TRAY UNIT SUPPLIER N/A 0 / O Q 563 POWER BASE EDHARD P-4010 29051 SA4027 120 1 15 NEMA 5-15 m � 564 CONTAINER BIN RUBBERMAID 2620 � Do 565 SPICE CART-5 TI ER NEW AGE 96072 co 566 1 NGREDI ENT BI N WITH SLI DI NG LI D CAMBRO IB27 � I 567 MOBILE SUGARING CART BIN CHANNEL MANUFACTURING 600 -- 4 568 REFRIGERATOR-REACH-]N,ONE SECTION HI NGED FULL DOOR NORLAKE NR241SSS/0 115 1 10 15 NEMA 5-15 Lj 569 REFRIGERATOR-REACH-IN,ONE SECTION HINGED HALF DOORS NORLAKE NR242SSS/0 115 1 10 15 NEMA 5-15 I I 571 REFRIGERATOR-REACH-IN,TWO SECTI ON HI NGED FULL DOOR NORLAKE NR522SSS/0 115 1 12 15 NEMA 5-15 572 REFRIGERATOR-REACH-1 N,TWO SECTION HI NGED HALF DOORS NORLAKE NR524SSS/0 115 1 12 15 NEMA 5-15 i 573 FREEZER-REACH-IN,ONE SECTION HINGED FULL DOOR NORLAKE NF241SSS/0-025 115 1 12 15 NEMA 5-15 574 FREEZER-REACH-IN,ONE SECTION HI NGED HALF DOORS NORLAKE NF242SSS/0-025 115 1 12 15 NEMA 5-15 575 FREEZER-REACH-IN,TWO SECTION HINGED FULL DOORS NORLAKE NF522SSS/0-025 115 1 14 20 NEMA 5-20 576 FREEZER-REACH-IN,TWO SECTION HINGED HALF DOORS NORLAKE NF524SSS/0-025 115 1 14 20 NEMA 5-20 577 FREEZER-REACH-IN,THREE SECTION HINGED FULL DOORS NORLAKE NF803SSS/8-025 115 1 11 15 NEMA 5-15 578 REFRIGERATOR-REACH-1 N,THREE SECTION HI NGED FULL DOORS NORLAKE NR763SMS/8-025 115 1 12 15 NEMA 5-15 S HE E-._ . •w 583 DUAL REFRIGERATOR/FREEZERREACH-IN,FREEZER ONTOP DELFIELD SMDBRI-SH 115 1 14 20 NEMA 5-20 584 DUAL REFRIGERATOR/FREEZER REACH-IN,REFRIGERATOR ONTOP DELFIELD SMDTRI-SH 115 1 14 20 NEMA5-20 'y> 624 640 SOFT SEATI NG-CLUB CHAI RS BEAUFURN SEE NATIONAL ACCOUNTS z 640G DD CLUB CHAI R COLOR:MOCHA JOB#: D1600=,- DATE: 03/1 / PC#: 33036C . - C.M. V. LAN& ,. w.. i c CONVENIENCE POWER NOTE F ` NOTE: CONVENIENCE POWER IS NOT PROVIDED ON THIS PLAN. LOCATIONS FOR CONVENIENCE POWER TO BE REVIEWED W/ FRANCHISEE. TYPICAL LOCATIONS FOR ADDITIONAL OUTLETS: , FRONT AND BACK LINE COUNTERS, OFFICE, ABOVE CEILING IN � SALES AREA AND VESTIBULE, ROOF FOR HOLIDAY LIGHTING. �F POS NOTE: GENERAL CONTRACTOR TO PROVIDE FOR P.O.S. SYSTEM AS SHOWN ON ELECTRICAL DRAWINGS OR, AT MINIMUM " THE FOLLOWING CONDUITS: y PREP AREA A) 21/2" I.D. FROM 4x4x3 JUNCTION BOX LOCATED BEHIND OFFICE DESK UP THE WALL TO ABOVE CEILING. B) FROM A HUB IN THE FRONT LINE CHASE UNDER SLAB TO WALL BEHIND DISPLAY RACKS PROVIDE THREE (3) 2" CONDUITS WITH 2'-0" SWEEPS AT ENDS. TERMINATE ABOVE CEILING. (UNDER FLOOR IF BASEMENT). C) NOT USED D) 2"x4" ELECTRICAL BOX 6'-0" A.F.F. WITH 1" CONDUIT IN WALL TO ABOVE CEILING. CENTER 32"x32"0/4" 0- ALL EXISTING LIGHTS IN THE BACK OF STORE TO PLYWOOD BLOCKING IN WALL FOR VDU UNIT. THE MAXIMUM CONNECTION LENGTH BETWEEN A VDU AND ITS DEDICATED CPU IN THE FRONT LINE CHASE IS BE REPLACED WITH LED LIGHT FIXTURES. REPAIR .: 75'-0". THE CONNECTION THEN GOES TO THE OFFICE. G.C. TO PROVIDE ONE ISDN TELEPHONE JACK IN THE } t AND REPLACE CEILING TILES AS REQUIRED OFFICE. NOTIFY DUNKIN' DONUTS IF ISDN SERVICE IS NOT REGIONALLY AVAILABLE. , E) (OPTIONAL) 2"x4" ELECTRICAL BOX IN FRONT LINE CHASE WITH 1" CONDUIT OVER TO HUB AT MAIN CASH STATION. THIS IS FOR COUNTER MOUNTED VDU UNIT AT COFFEE STATION. SEE P.O.S. CEILING LEGEND KIT. I A17 NOTE "B" 02-23-12 4 HALL OFFICE _ A3 8 ® A2P0 W/ OVERLAY 2x2 LAY-IN (TYP FIXTURE � INSC-1 EXTERIOR UP / DOWN _. :,:.,•;,: 2x4 LAY-IN LIGHT FIXTURE SCONCE LIGHT LED-6 ., .: ^;}i :, WSCX-1 EXTERIOR GOOSENECK LIGHT ., 4 -cyw �# ; `> A1P (NO OVERLAY) (TYP.) s —10 2x4 LAY-IN LIGHT FIXTURE WSCX-2 EXTERIOR WALL MOUNT STEM LIGHT '> Al PO O w. W/ OVERLAY (TYP.) GINTER �` ®A1 FLUSH 2x4 LAY-IN LIGHT FIXTURE CEILING NI6RSPEAKER F ) VI/^ TILE START o O SOFFIT LINE IN SOFFIT Z O6 POINT W/ ACRYLIC LENS (TYP.) . < CR-24 2x4 LED EXTERIOR SPEAKER / A2 CREE #CR24-40L-35K-S V o ADJUSTABLE SPEAKER o SEE P. P - - - - -- - _ _ _ _ � CR-22 2x2 LED, VOLUME CONTROLS ` � � `` NOTo � A , A A CREE #CR22-40L-35K-S ® K DOWN LIGHT c v'. TOILET HD p 4 I LED-4 OO LR-6 DOWNLIGHT LED, o. / D 4 N\_SERVING CREE #LR6-DR1000-US +P PENDANT LIGHT FOR COFFER o / I o I AREA g ®X EXIT SIGN iJ y- // �� _ __ __ �� _ _ _ __ O RECESSED CAN LIGHT SEE POS �j (EXISTING OO RECESSED CAN DOWN LIGHT z RETURN s „ „ 1 LED-1 FIXTURE (LED) TOILET NOTE E HEIGHT) ® CEILING EXHAUST REGISTER _' 3 J•,I / / Apo-2 EXTERIOR AWNING WASH en � �j II / LIGHTS (LED) " 5 �' ® SUPPLY AIR DIFFUSER ` RECESSED CAN EXTERIOR 5'-0", MAX s Al Al E DOWN LIGHT FIXTURE I I I Al O .; ?,°;.: GYPSUM BOARD CEILING L D 4 =C TRACK HEAD & LED LAMP G EXTERIOR WALL PACK LIGHT qs ® SURFACE MTD. WALL-WASH P I A5 FLUE C C8,C12,C16,C24 LIGHT FIXTURE >' Y=Y g EMERGENCY LIGHT , Al DISPLAY jl� SP, SP1 PENDANT LIGHT FIXTURE AC "�" r' LIGHTS FOR EXTERIOR DECORATIVE WALL MARS AIR CURTAIN MEN 4 MERCHANDI ER 8 WP PACK LIGHT 800-421-1266I,y A 1 A1711, 9 02-23-,2 LIGHTING SCHEDULE x_awu� ADJOINING Al A, Al t CODE DESCRIPTION MANUF. PRODUCT "`fY TENANT L D 4 L D 4 L D 4 INTERIOR SPACE 1 Al 2x4 REC. FLUOR. W/ACRYLIC LENSE & WM T8 MET 2GR8-332A-UNV-ADV-EEX �- A1P 2x4 PARABOLIC W/ T8WM (NO OVERLAY) MET 2EP3GX332S361-UNV-ADV-EEX-OAO CD j P2 Al A1PO 2x4 PARABOLIC W/ OVERLAY & T8WM MET 2EP3GX332S361-UNV-ADV-EEX-OAO o A2PO 2x2 PARABOLIC W/ T8WM MET 2EP3GX2U6-S331-UNV-0L a DECORATIVE CEILING S B 42W COMPACT FLUOR. DOWNLIGHT HALO H880E-870C ELEMENTS AS MANUF. Z v� 1 BL 2x2 DIR.-INDIR. REC. BATHROOM LIGHT LOL CFS-2GPF2FT-120CD 0 m BY DGS — SEE Al Al Al NATIONAL ACCOUNTS, C TRACK HEAD - OPEN STYLE HALO L703MB w 1OW LED LAMP - z w ALSO DETAIL 2/A2. / ��`„ O L D 4 L D 4 L D 4 C8 MENU BOARD LIGHT T5HO - 8' ELLIPTIPAR F144-V8B S22-122-LXX w/LENS Lv ~ C/-) Cc—, n — ENERGY EFFICIENCY GUIDELINES C12 MENU BOARD LIGHT T5HO - 12' ELLIPTIPAR F144-V12B S22-122-LXX w/LENS v Q 1. RELAMP & REBALAST FIXTURES C16 MENU BOARD LIGHT T5HO - 16' ELLIPTIPAR F144-V16B S22-122-LXX w/LENS Go Li ~ INTERIOR: FROM T12 TO SUPER T8 FLUORESCENT LAMPS 7- EXTERIOR: FROM EXISTING TO APPROPRIATE WATTAGE PULSE START METAL HALIDE C24 MENU BOARD LIGHT T5HO - 24' ELLIPTIPAR F144-V24B S22-122-LXX w/LENS LAMPS & FIXTURES — SEE DBI'S SITE LIGHTING CRITERIA FOR MORE INFORMATION I 2. INSTALL OCCUPANCY SENSOR CONTROLS IN BATHROOMS, OFFICES & STORAGE CLOSETS JL INCAND. DOWNLIGHT W/ WHITE TRIM LEV 9875 �z 3. REPLACE ANALOG HVAC THERMOSTATS W/ PROGRAMMABLE THERMOSTATS K 42W COMPACT FLUOR. DOWNLIGHT W/ LENS HALO PD7/V142E/7VL1 C 4. INSTALL TIME CLOCKS W/ INTERRUPTIBLE CONTACTORS ON OLDER MODEL BAGEL OVENS REUSE EXISTING GRID; ® ELECTRICAL PANEL LP LOW-BAY 12" RAW ALUM. FINISH ATLANTIC SBS12-242E 1/2PL-24-PL-HSHG REPAINT WHITE; NEW 5. REPLACE EXISTING WALK—IN COOLER & FREEZER MOTORS W/ ELECTRONICALLY CEILING TILES/LIGHTS AS SHOWN, TYP COMMUTATED MOTORS LED-1 LED DOWN LIGHT W/RC-6 HOUSING CREE LR-6/DR1000 W/ LT-6 REFLECTO 6. IMPLEMENT A WEB—BASED ENERGY MANAGEMENT SYSTEM , P HANGING ORANGE PENDANT LIGHT BOCK LIGHTING P07-DD 110-PMS 165 ELECTRIC LIGHTING PLAN NOTE: SEE DEWS "ENERGY EFFICIENT & FUTURE FRIENDLY STEPS TO SAVE" PAMPHLET FOR OC OPTIONAL-WALL MOUNTED OCCUPANCY SENSOR-WHITE WS WS-200-W MORE INFO. NOT ALL GUIDELINES MAY APPLY TO EVERY STORE — CONSULT CONSTRUCTION MANAGER / OWNER SP APRICOT PEND. 9.5" SHADE WILSHIRE DD APR CONE I SCALE: 1/4 = 1 -0 / / NOTES SP-1 PINK PENDANT 9.5" SHADE WILSHIRE DD/PNK/CONE "� W-EBU 2-HEAD BATTERY PACK EX LL50 0 1. PANEL BOARDS ARE PROVIDED FOR CHECKING TOTAL SERVICE REQUIREMENTS E.C. Q _ SHALL USE JUDGMENT IN REVISING CERTAIN CIRCUIT'S AND ARRANGING EQUIPMENT ON X LED EXIT W/ BATTERY EX VEX-U-BP-WB-WH 0 PANEL BOARDS IN THE MOST ECONOMICAL MANNER. E.C. SHALL DETERMINE FINAL z SERVICE LOAD REQUIREMENT FROM LOADS GIVEN IN PANELBOARDS AND PROVIDE ComBo COMBO LED EXIT / (2)HEAD EBU EX VEX-U-BP-WB-WH-EL90 O ---j _ SERVICE ACCORDINGLY. Q ,M 2. INSTALL ALL ELECTRICAL OUTLET BOXES HORIZONTAL AND FLUSH IN WALLS WHERE EXTERIOR POSSIBLE. PROVIDE APPROPRIATE FLUSH MOUNTING RECEPTACLE BOXES AND CONDUIT CJ O �• — —_ AS REQUIRED FOR MOUNTING OF OUTLETS ON CONCRETE WALLS. EXTERIOR AWNING LIGHT MERCURY M4000-1-32-OCT-ELB-UNV -� -- 3 TOTS GNR SIGN JUNCTION BOX TO BE MOUNTED ON INSIDE OF WALL. EXTEND CIRCUIT E INCAND. DOWNLIGHT W/WHITE TRIM HALO H7T/410W o Li 4• SEE "TECHNICAL REQUIREMENTS FOR THE COMTREX SYSTEMS CORPORATION DUNKIN' G BILK EYELID WALL PACK - 26W LPC 35710-12-1262PL �-- i d°0- L DONUTS P.O.S. SYSTEM" FOR ALL INFORMATION RELATING TO CASH REGISTER WIRING. GF 10OW MH GROUND FLOOD LTH TFM100MTA-TB-DBL-LPI c=� j(FURNISHED BY DUNKIN' DONUTS.) 5. PROVIDE CORD WITH GROUND AND CAP FOR EACH COFFEE MAKER AND CARBONATOR. LED-2 EXTERIOR 3" LED FIXTURE CONTRAST LIGHTING LED R347-13MG3V1ry 6. SEE INTERIOR ELEVATIONS FOR DIMENSIONS AFFECTING THIS WORK. RH EXT. WEATHERPROOF EM REMOTE HEAD EX ZIP-2 7. SEE SHEET K2 FOR EQUIPMENT CONNECTION REQUIREMENTS. r � SHEETNOTES 8 E.C. SHALL PROVIDE MUSIC SYSTEM PER DUNKIN' DONUTS SPECIFICATIONS. SW-22F-3 SITE LIGHTING USA SVL22F-III-350PS-MT-I-DBM-LAMP -- Lij 9• E.C. SHALL PROVIDE DOORBELLS AND BUZZERS PER DUNKIN' DONUTS SPECIFICATIONS. - - - - DBM 10•E.C. SHALL VERIFY LOCATION OF EQUIPMENT WITH DUNKIN' DONUTS FRANCHISE OWNER. TC DIGITAL TIME CLOCK TORK DTS200A O1 GWB CEILING/ SOFFIT 0 PYLON AND EXTERIOR SIGNS WSC-1 EXTERIOR DARK BRZ UP/DOWN SCONCE W/ LENS SLP 8340-10/9008-12 O2 NOT USED WSCX-1 SIGNLITE FIXTURE W/ 18" ARM W/ LAMP TTF A812-41-E5-26W-CFWTMPL-T CONSULT OWNER FOR LOCATION AND SIZE OF PYLON SIGN REQUIRED; CONNECT TO A35,O "3 HWH FLUE SUPPLY ALL WIRE, BOXES, AND CONDUITS REQUIRED. CONNECT EXTERIOR SIGNS TO CIRCUIT WSCX-2 SIGNLITE FIXTURE W/ 18 ARM W/ LAMP TTF L-716-BK-18 /WM-1BK/EN-1260-R-A A31. CONNECT MENU BOARD TO CIRCUIT A33. VERIFY LOCATION WITH OWNER.O -DB EXTERIOR ARCH. WALL PACK-175W MH LITHONIA WSR175M-MD-120-LPI-DBZ 4 HOOD FOR SANDWICH STATION WSR ••—• o PICK—UP "CLOCK SIGN" ELECTRICAL PLAN KEYNOTES LIGHTING SCHEDULE NOTES SHEET -- - ,, M . SUSPENDED FROM CEILINGEl EXTERIOR LIGHTS, PHOTOCELL ON, TIME CLOCK OFF. 1. PROVIDE ALL FIXTURES COMPLETE WITH LAMPS. REFER TO NATIONAL ACCOUNT SOURCE INFO FOR LAMP SPECS & O6 MENU BOARDS VILLA LIGHTING RE-LAMPING PROGRAM. 0 POWER FOR EXTERIOR SIGNS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. 2. ALL INCANDESCENT LAMPS SHALL BE RATED 130 VOLTS. FOOTCANDLE NOTE: 1. MINIMUM LIGHTING LEVEL (FOOTCANDLES IN 7 MENU BOARDS LIGHTS FRONT OF HOUSE (FOH) = 35FC MIN. O 3. ALL BALLASTS SHALL BE HIGH POWER FACTOR. FLUORESCENT BALLASTS FOR T8 LAMPS TO BE ADVANCED2. 1• � ....,t ki4;aulwf .Pe6 OF LIGHTING LEVEL HOUSE (BOH) = 50FC DLES NOTE: "P.O.S.", ALL POWER OUTLETS FOR P.O.S. DEVICES ARE DEDICATED CIRCUITS WITH MANUFACTURED OPTANIUM WATT MISER, EXCEPT OUTDOOR FIXTURES TO BE ZERO-DEGREE MAGNETIC BALLASTS. BACK OF MINIMUM F O8 THIRD WIRE ISOLATED GROUND. AN IG IS AN INSULATED WIRE, SEPARATED FROM ALL 4. PROVIDE HOLD DOWN CLIPS FOR EACH CORNER OF FLUORESCENT GRID TROFFERS. JOB ' : D 1600 MIN. . IN PENDANT LIGHTS BACK TO THE BUILDING MAIN OR COMPLEX P RUNNING OTHER GROUND WIRES, RUNOWER 6. COORDINATE AND VERIFY ALL FIXTURE INFORMATION, TYPES AND FINAL LOCATIONS WITH THE REFLECTED DATE: 03 15 , 3. MINIMUM LIGHTING LEVEL (FOOTCANDLES IN Og OPTIONAL CEILING COFFER PANEL. NEMA STANDARD NING I.G. FOR THE RECEPTACLE AND PLUG. USE IG 5. PROVIDE ALL REQUIRED MOUNTING OR HANGING HARDWARE. TOILET ROOMS = 35FC MIN. DUPLEX OR QUADPLEX OUTLETS: (I.E., HUBBELL IG-5262, IG 5362 OR EQUIVALENT). CTED CEILING PLAN. 7. LAMPS SHALL BE AS MANUFACTURED BY SYLVANIA WESTINGHOUSE GENERAL ELECTRIC OR APPROVED EQUAL. PC#: 330360 C.M. V. LANGL ..,_...._ _. ELECTRIC PANELBOARDS AS SHOWN ARE DIAGRAMMATIC. OWNER'S G.C. IS RESPONSIBLE FOR SIZING FINAL SERVICE LOAD 1. POS TERMINAL INFORMATION: 110V AC DUPLEX OUTLETS BASED ON LOADS OF EQUIPMENT AS SHOWN. 2. RECEIPT PRINTER INFORMATION: 110V AC DUPLEX OUTLETS, SHARED WITH TERMINAL OUTLETS, & WIRED DIRECTLY TO TERMINALS 3. REMOTE PRINTER INFORMATION: 110V AC DUPLEX OUTLETS, WIRED TO rt, O 4.TERMINALS DIUAINFORMATION 5 110VOACI DUPLEX OUTLETS,CHASELE ETS, & WALL, CEILING, OR , PEDESTAL MOUNTING MAIN DISTRIBUTION PANELBOARD =r. HAND 5. OFFICE AREA INFORMATION: 110V AC QUADPLEX OUTLETS 1 MODEM SINK PREP AREA LINE REQUIRED FOR SUPPORT, & 2ND MODEM LINE OPTIONAL FOR VOLTAGE: 120/208 PHASE: 3 LOCATION: SEE PLAN (EXISTING) CREDIT CARD PROCESSING BUS AMPS: 400 WIRE: 4 MOUNTING: SURFACE co 6 MAIN OVERCURRENT DEVICE: REMARKS: . NETWORK HUB INFORMATION: 110V AC DUPLEX OUTLETS, LOCATED IN MAIN CIRCUIT BREAKER / (EXISTING EQUIPMENT IN FRONT COUNTER CABLE CHASE, CONNECTS TO TERMINALS, VDU'S, & AMP ., S: 400 , / THIS ROOM; RELOCATE CIRCUITS ON EXISTING BACK OFFICE COMPUTER SYSTEM, & ORDER INFORMATION ROUTED TO .Y/ BREAKER LOAD PANEL BOARDS AS HUB THEN TO VDU'S & OFFICE AMP POLE KVA HAS CKT DESCRIPTION AMP POLE KVA HAS 1 REQUIRED; PANEL LAYOUT � BREAKER LOAD CKT DESCRIPTION IS DIAGRAMMATIC ONLY.) 1 PANEL "A" 150 3 XX.X A 2 PANEL "B" 2501 3 XX.X A NOTE: 3 (SEE NOTE BELOW) B 4 B 1. COORDINATE ALL EQUIPMENT UTILITY INFORMATION SHOWN ON THIS SHEET WITH THE DUNKIN' BRANDS EQUIPMENT 5 C 6 C 1 A37 SCHEDULE AND EQUIPMENT MANUFACTURER'S CUT SHEETS. 7 HVAC UNIT #1 40 3 A 8 HVAC UNIT #2 40 3 A �,( �C, ,\� SEE P.O.S 2. ALL ELECTRIC INFORMATION SHOWN ON THIS PAGE IS 9 B 10 B M, f`I T. �� A39 NOTE "B" REQUIRED FOR EQUIPMENT - ALL CONVENIENCE POWER 11 LOCATIONS ARE TO BE DETERMINED BY FRANCHISEE. C 12 C OFFICE �"} J A16 3. OUTLETS ARE SHOWN FOR POSITIONING PURPOSES ONLY. 13 SPARE - 3 A 14 TOASTER 20 2 A HALL _C PROVIDE 3 SEPARATE 2" RIGID CONDUITS J REFER TO EQUIPMENT SPECIFICATIONS FOR AMOUNT OF POWER 15 B 16 1.6 g IN POS AREA FOR IG. POWER & LOW �\\ TO EACH PIECE OF EQUIPMENT AND TYPE OF RECEPTACLE IF VOLTAGE COMMUNICATIONS TO FRONT LINE i, REQUIRED. 17 C 18 ICE MACHINE 20 2 1.4 C IN, 0I III I EQUIPMENT UNDER SLAB UP INTO COMMON 4. PREFERRED ELECTRIC SERVICE IS 120/208V, 3 PH, 4W, 19 SPARE 30 3 A 20 ''� 1.4 % 20 A �z CHASE IN FRONT LINE CASEWORK. 400A. A20 20 I I I II I 21 B 22 HVAC UNIT #3 40 3 B .0 gs„ °° ~�LOry JL BIZ J CONVENIENCE POWER NOTE 25 SPARE , q 23 C 24 C B18 0 B25 III - 20 26 q NEW 111 vi NOTE: 27 OVEN CONTROL 20 1 .5 B 28 FLAT SCREEN TV - 2 B CONVENIENCE POWER IS NOT PROVIDED ON THIS PLAN. 29 OVEN EXHAUST FAN 20 1 .6 C 30 C H.W. v �° 1) I I I o � I� LOCATIONS FOR CONVENIENCE POWER TO BE REVIEWED W/ 31 WALK-IN COOLER 20 2 ,,32 A 32 SPARE 20 2 A SEE v r� FRANCHISEE. TYPICAL LOCATIONS FOR ADDITIONAL OUTLETS: Ur NOTEP'DS \� / T �I FRONT AND BACK LINE COUNTERS, OFFICE, ABOVE CEILING IN 33 1.32 B 34 g 9' r5 i EXISTING / 11 I SALES AREA AND VESTIBULE, ROOF FOR HOLIDAY LIGHTING. 35 WALK-IN FREEZER 20 2 4.2 C 36 AIR CURTAIN (REAR DR) 20 2 .8 C v, �- RESTROOM `V�• �� �'� / I J .T I III SERVING 37 4.2 A 38 8 A � �'-, - G 39 SPARE 2 B 40 AIR CURTAIN (DT) 20 1 .6 B -J '- ARE ELECTRICAL PLAN KEYNOTES �' A .S,i,.�, s i. r� 41 C 42 SPARE 20 1 C EXISTING � / 30 40 EXTERIOR LIGHTS, PHOTOCELL ON, TIME CLOCK OFF. PHASE A LOAD (KVA): . B42 B42 32 A14 A2 A4 FRONT LINE CHASE IN KNEE WALL OF FRONT PHASE B LOAD (KVA): "` r RESTROOM ^ / // B1 B2 LINE. NOTE: KNEE WALL IS PART OF MILLWORK a POWER FOR DISPLAY CASES, BALLAST TO BE PHASE C LOAD (KVA): " 632 PACKAGE, NOT FIELD BUILT. MOUNTED IN THE DISPLAY CASE BASE. ALLOW TOTAL LOAD (KVA): / b 8' PIG TAIL. / ///� ti0^ ❑3 POWER FOR EXTERIOR SIGNAGE. REFER TO ¢a ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. ij 0 " use PANELBOARD VOLTAGE: 120 208 PHASE: 3 � SALES - / LOCATION: SEE PLAN BUS AMPS: 150 WIRE: 4 MOUNTING: SURFACE _.____..._.......: ' NOTE: REFER TO INTERIOR ELEVATIONS MAIN OVERCURRENT DEVICE: REMARKS: FOR MORE INFORMATION ON SANDWICH AREA CIRCUIT RRE STATION OUTLET CONFIGURATION. e ELECTRIC LEGEND AMPS: 150 BREAKER LOAD BREAKER LOAD ° CKT DESCRIPTION CKT DESCRIPTION AMP POLE KVA HAS AMP POLE KVA HAS q� DUPLEX OUTLET 12" A.F.F. UNLESS NOTED OTHERWISE 1 LIGHTING * P/S 20 1 1.5 A 2 CASH REGISTERa �S ®x G=G.F.I. C=ABOVE COUNTER WP=WATERPROOF 20 1 .2 A � � 3 LIGHTING * P/S 20 1 1.5 B 4 CASH REGISTER 20 1 .2 B a � 6 X = NUMBER OF GANGED DUPLEXES IF MORE THAN ONE i E.C. TO ADD RECEPTACLES IN 5 LIGHTING * P/S EXISTING 20 1 1.5 C 6 SPARE 20 1 C SEATING AREA FOR PATRONS 7 LIGHTING * P/S EXISTING 20 1 1.5 A g SPARE 20 1 A U LAJ ' POWER OUTLET - 208 VOLT, X = AMPERE ' LAPTOPS. SUGGESTED x 9 LIGHTING * P/S EXISTING 20 1 1.5 B 10 LAPTOP OUTLET *** SS 20 1 1.5 g LOCATIONS ARE SHOWN. TRANSIENT VOLTAGE SURGE SUPPRESSOR 11 LTG GNL+REF 20 1.5 VERIFY ALL WORK W/ OWNER. O 1 C 12 SPARE 20 DUPLEX OUTLET 1 C G9i JO JUNCTION BOX 13 EXTERIOR LIGHTING**TC 20 1 1.5 A 14 COFFEE STATION 20 1 1.5 q s,p 15 SPARE 20 1 B 16 UNDERCOUNTER REFRIG. 20 1 .6 B V 17 LIGHTS, EXIT & EMERG. 20 1 1.5 C 18 COFFEE STATION 20 1 1.5 C FUSED DISCONNECT SWITCH 19 DISPLAY CASE BALLAST 20 1 .9 A 20 BOOSTER PUMP 20 1 1.8 A C° c� 7 7 21 LCD MENUBOARD 20 , 5 B 22 HWH IGNITER 20 1 .2 B RECEPTACLES TAGGED WITH "USB" IN WALL CLOCK - EDWARDS 1882, THE SALES & SEATING AREAS SHALL BE © # 23 LCD MENUBOARD 20 , 5 C 24 UNDERCOUNTER REFRIG. 20 1 .6 C o \ HUBBELL #USB15X2W / SS26 COMBO USB MOUNTED 8'-0" A.F.F. r7 25 COOLER 20 1 1.2 A 26 UNDERCOUNTER FREEZER 20 1 .6 A o CHARGER WITH TAMPER-RESISTANT FTC TIME CLOCK (BY OTHERS - OPTIONAL) 27 COOLER 20 , 1.4 B 28 UNDERCOUNTER REFRIG. 20 1 6 B RECEPTACLE. G9j EXISTING `rB� VESTIBULE 29 WP RECEPTACLES 20 1 .18 C 30 REF & BACK BAR 20 1 1.5 C 0 m cn RECEPTACLES SHALL BE WHITE WITH USB � HAND DRYER (BY OTHERS) STAINLESS STEEL COVER PLATE AND ARE Al2 31 EXTERIOR SIGNS 20 , 1.5 A 32 BELLS/BUZZERS/CLOCKS 20 1 .5 A w TO BE MOUNTED AT 3' 2-1/2" AFF. �� Q DOOR BUZZER - EDWARDS #115-4 WITH SWITCH 33 FREEZER 20 1 1.4 B 34 HAND DRYER 25 1 2.0 B O� 35 FREEZER 20 , 1.2 C 36 HAND DRYER 25 0 BUZZER ALARM - EDWARDS #1065-65 W/592 1 2.0 C 24 VOLT TRANSFORMER UNDER COMMON PLATE 37 OASIS 20 1 0.6 A 38 GENERAL OUTLETS 20 1 1.5 A U Q Q DOOR BELL - EDWARDS #55-465, MOUNTED 8'-0" A.F.F. 39 OASIS 20 1 0.1 B 40 GENERAL OUTLETS 20 1 1.5 B w � 41 FIRE WARNING SYSTEM 20 1 .5 C 42 TOASTER FAN 20 1 .6 C � Z ❑S BUZZER SWITCH - EDWARDS #44 DOOR CONTACT ELECTRIC POWER PLAN- o DOOR BELL BUTTON - EDWARDS #852 PHASE A LOAD (KVA): O PHASE B LOAD �KVA�: PHASE C LOAD ((((((KVA): SCALE. 1/4" = 1'-0" TOTAL LOAD (KVA): 4 * P/S = PANEL SWITCHED NOTE: "P.O.S.", ALL POWER OUTLETS FOR P.O.S. DEVICES ARE DEDICATED CIRCUITS WITH ** TC = TIME CLOCK CONTROL THIRD WIRE ISOLATED GROUND. AN IG IS AN INSULATED WIRE, SEPARATED FROM ALL OTHER GROUND WIRES, RUNNING BACK TO THE BUILDING MAIN OR COMPLEX POWER PANEL. NEMA STANDARD L5-15R I.G. FOR THE RECEPTACLE AND PLUG. USE OF IG C' s DUPLEX OR QUADPLEX OUTLETS: (I.E., HUBBELL IG-5262, IG-5362 OR EQUIVALENT). PANELBOARD "B$f < VOLTAGE: 120 208 PHASE: 3 LOCATION: SEE PLAN - BUS AMPS: 250 WIRE: 4 "tea s MOUNTING: SURFACE t POS NOTE: MAIN OVERCURRENT DEVICE: REMARKS: CIRCUIT #M-2 ,,.. GENERAL CONTRACTOR TO PROVIDE FOR P.O.S. SYSTEM AS SHOWN ON ELECTRICAL DRAWINGS AMPS: 250 ! O L� El OR, AT MINIMUM THE FOLLOWING CONDUITS: La_D A) 2 1/2" I.D. FROM 4x4x3 JUNCTION BOX LOCATED BEHIND OFFICE DESK UP THE WALL TO BREAKER LOAD BREAKER LOAD ABOVE CEILING. CKT DESCRIPTION CKT DESCRIPTION O_ AMP POLE KVA HAS AMP POLE KVA HAS s B) FROM A HUB IN THE FRONT LINE CHASE UNDER SLAB TO WALL BEHIND DISPLAY RACKS „ 1 COFFEE MAKER 40 2 3.5 A 2 COFFEE MAKER 30 A Q ----� 2 1.9 U O DMB POWER CONDUIT TO -�'� o ii PROVIDE THREE (3) 2 CONDUITS WITH 2-0 SWEEPS AT ENDS. TERMINATE ABOVE CEILING. 3 3.5 B 4 PANELBOARD lY( DMB POWER AND DATA ON SOFFIT (UNDER FLOOR IF BASEMENT). 1.9 B 0 �p CENTERED FROM POS COUNTER AT C) NOT USED. 5 -' -j .r DMB DATA CONDUIT ��� FRONT LINE D) 2"x4" ELECTRICAL BOX 6'-0" A.F.F. WITH 1" CONDUIT IN WALL TO ABOVE CEILING. CENTER 7 A 8 1 9 q O ~TO OFFICE iii 32"x32"x3/4" PLYWOOD BLOCKING IN WALL FOR VDU UNIT. 9 SPARE 30 E) (OPTIONAL) 2"x4" ELECTRICAL BOX IN FRONT LINE CHASE WITH 1" CONDUIT OVER TO HUB 2 B 10 TURBOCHEF OVEN 30 2 1.75 B -IJ co AT MAIN CASH STATION. THIS IS FOR COUNTER MOUNTED VDU UNIT AT COFFEE STATION. 11 C 12 1.75 C THE MAXIMUM CONNECTION LENGTH BETWEEN A VDU AND ITS DEDICATED CPU IN THE FRONT 13 SOFT SERVE 30 2 2.0 A 14 TURBOCHEF OVEN 30 2 1.75 A _F j e LINE CHASE IS 75'-0". THE CONNEC1ON THEN GOES TO THE OFFICE. G.C. TO PROVIDE ONE II ISDN TELEPHONE JACK IN THE OFFICE. NOTIFY DUNKIN' DONUTS IF ISDN SERVICE IS NOT 15 2.0 B 16 1.75 B REGIONALLY AVAILABLE. ,7 ESPRESSO 30 2 1.55 C 18 ICED COFFEE BREWER 30 2 2 C ( LLB C i 19 1.55 A 20 21 COOLATTA MACHINE 25 2 A ..� i 23 2 1.5 B 22 COOLATTA MACHINE 20 2 1.5 B L�J POS COUNTER AT 1.5 C 24 1.5 C ® ®p ® ® ® i 1.REFER TO DUNKIN' BRANDS "POS DEPLOYMENT METHODOLOGY" AND APPROVED VENDORS FOR 25 HOT WINTER BEVERAGE 30 2 1.7 A 26 VITA MIX 20 1 .32 A °'"" i °'� FRONT LINE COMPLETE INFORMATION AND SPECIFICATIONS REGARDING POS SYSTEM INSTALLATION. ' 27 1.7 B 28 BEVERAGE MERCHANDISER 20 1 1.3 g �-�= -- -~------------ i 2.RETAIL INFORMATION SYSTEMS EQUIPMENT MUST BE ON DEDICATED CIRCUITS. R.I.S. EQUIPMENT MAY SHARE CIRCUITS WITH OTHER R.I.S. EQUIPMENT, BUT NO OUTSIDE EQUIPMENT SHOULD BE 29 SPARE 20 1 C 30 V.D.U. OUTLET 20 1 1.6 C ri ON THESE CIRCUITS. 31 HATCO HASH BROWN HOLD V.D.U. OUTLET 20 1 1.6 A 20 1 .72 A 32 3.ALL OUTLETS FOR R.I.S. EQUIPMENT SHOULD HAVE A THIRD WIRE ISOLATED GROUND. 33 TOILET EXHAUST FAN 20 1 .6 B 34 SPARE 20 1 B ------�-, 4-LOCATE ALL RECEPTACLES FOR R.I.S. EQUIPMENT WITHIN 4' OF THE EQUIPMENT THEY SERVE. 35 TOILET EXHAUST FAN 20 1 .6 C 36 SPARE 20 1 C SHEET 5.ALL R.I.S. DEVICES AT A REMOTE LOCATION FROM THE HUB SHALL REQUIRE CONDUIT DEDICATED FOR R.I.S. USE. THE MINIMUM SIZE FOR ALL NETWORK CONDUIT IS 1-1/2". 37 OFFICE 20 1 1.5 A 38 UTILITY EXHAUST FAN 20 1 •9 A � REFER TO EXTRANET FOR DMB GUIDELINES FOR PROPER 6.ALL NETWORK DEVICES REQUIRE CAT 5 CABLE WITH RJ-45 JACKS. 39 SOUND SYSTEM 20 1 •5 B 40 CARTER-HOFFMAN HOLD 20 1 1•2 B LOCATION OF DIGITAL MENU BD. RECEPTACLES. 7.PROVIDE POWER CONDITIONERS/ UNINTERRUPTED POWER SUPPLIES AS RECOMMENDED 41 OFFICE COMPUTER 20 1 .5 I ;z co / C 42 PRINTER(S) 20 1 1.0 C 0 0 0 LOCATION CAN VARY DEPENDING ON SPACE AVAILABLE REQUIRED BY APPROVED VENDORS AND ADQSR. N °' a o_ AND SIZE OF BOARDS TO BE USED 8.ALL NETWORK CABLING/ CONDUIT MUST BE LOCATED A MINIMUM OF 12" FROM ANY ELECTRICAL PHASE A LOAD KVA : CONDUIT. PHASE B LOAD KVA : -- PHASE C LOAD KVA : TYPICAL ELEVATION ® BACK BAR 9 OPTIONAL TELEPHONE JACKS FOR OUTSIDE LINES MAY BE PROVIDED IN OFFICE AREA AND PREP TOTAL LOAD (KVA): SOB# D1 oOG N.T.S. AREA. DATE: 03� PC#: 3303 C.M. V. LANGLE)' - I r GET- 00 HAND (EXIISTING) NOTE: F'EE AND FIELD TEAM TO DETERMINE IF EXISTING BACK f 1 ROOM EQUIPMENT AND COLD/DRY STORAGE _ CAPACITIES CONFORM TO CURRENT STANDARDS. PREP r - OASI AREA KIT. OFFICE EEIE �� j I (EXISTING) HALL — — — EXIST. TIE INTO EXISTING -FCW f (EXISTING) COL WATER LINES IE INTO (EXISTING) ---110' HW----�� EXISTIN r-• •-•-FCW-• --------- _._. ._._._._ j FCW-•- LINES •-•-•-•-•- - �\ i II II I -w,' Hot----Jl__u.----JE------J 1 ICB INCOMING COLD WATER LINE TO BE / 1 P1 Winter o Bev. 1- 1/2' DIAMETER MINIMUM PER ,NEW , I PROVIDE FILTERED WATER SERVICE TO DUNKIN' BRANDS, INC. STANDARDS. w H.W. WATER FILTER `� ,� °' FRONT LINE EQUIPMENT IN INSULATED f n AND BOOSTER i CONDUIT INTO SERVICE SIDE OF FIELD U, �y BUILT KNEE WALL. �, PUMP BY G.C., 1 i --------------- - --------- = ' SEE SHEET P3. 9, ��� -I COFFEE I PLUMBING IN THIS STORE IS EXISTING. L = EXISTING I I REUSE WHERE POSSIBLE. UPGRADE TO MEET RESTROOM / , N , SERVING i ALL APPLICABLE STATE AND LOCAL CODES. CONNECT NEW PLUMBING TO EXISTING. — —1--—-FCW_=_____=— I --------- AREA i��O i�„i/---j------------------ --------- - EXISTING FRONT LINE CHASE IN KNEE WALL OF FRONT PLUMBING FIXTURE SCHEDULE RESTROOM ` ,��� �i i' LINE. NOTE: KNEE WALL IS PART OF MILLWORK MARK DESCRIPTION WASTE VENT COLD HOT PACKAGE, NOT FIELD BUILT. LOCATION OF SUPPLY r � Y & WASTE SERVICE TO FRONT LINE IS WATER WATER 4J IS LOCATED ON THE SERVICE SIDE OF THIS WALL. * P 1 BACK BAR SINK 1 1/2" 1 1/2" 1/2" SINK PROVIDED AS PART OF EQUIPMENT PACKAGE - • , PLUMBER TO MAKE FINAL CONNECTIONS. ` CHEMICAL DISPENSER NOTES: PROVIDE P&G DISPENSER W/ DEDICATED WATER SUPPLY ® JANITOR'S SINK, (MOUNT �9p BOTTLE & DISPENSER ABOVE SINK) & PROVIDE P&G DISPENSER W/ DEDICATED WATER °Ty SUPPLY ® POT SINK (MOUNT BOTTLE & DISPENSER ABOVE SINK) IF EITHER OR BOTH ' ARE NOT PRESENT. � �" ; � EACH CHEMICAL DISPENSER MUST HAVE A DEDICATED WATER SUPPLY, LOCATED WITHIN 4 ���.�• 6p FEET OF THE DISPENSER. IT MUST PROVIDE TEMPERED WATER (ADJUSTABLE FROM oTy 60'-1207) WITH A FLOW RATE OF 4 GPM AT 40 PSI DYNAMIC/FLOWING PRESSURE (35 r SALES PSID MIN.). THE HOT AND COLD WATER SUPPLY LINES MUST HAVE CHECK VALVES TO PREVENT HOT/COLD WATER CROSSOVER, IF THE TEMPERING VALVE DOES NOT INCLUDE ?'ty THEM. IT MUST INCLUDE A SHUTOFF VALVE TERMINATING IN A GARDEN HOSE MALE eo FITTING. '" e pay AREA Y` NOTE: THE DEDICATED WATER SUPPLY SHOULD NOT HAVE ANY BACKFLOW PREVENTION (E.G. NO ATMOSPHERIC VACUUM BREAKER, ETC.), UNLESS REQUIRED BY THE LOCAL PLUMBING CODE OR UTILITY- EACH CHEMICAL DISPENSER INCLUDES AN INTEGRAL /j BACKFLOW PREVENTOR ASSE 1055). CONSULT DD CORPORATE SPECS/ CONSTRUCTION MANAGER FOR MORE INFO. ALSO SEE w Ln NATIONAL ACCOUNTS. Q a j z v, i EXISTING GENERAL NOTES 0_ m VESTIBULE LLJ _ L 1. THESE DRAWINGS ARE FOR SCHEMATIC DESIGN ONLY. IT IS UP TO EACH O LINDIVIDUAL DESIGNER TO SPECIFY AND ENGINEER THESE SYSTEMS FOR SITE Lv acn L � SPECIFIC LOCATIONS. I2� 2. ALL WORK SHALL COMPLY WITH ALL LOCAL AND STATE CODES AND AUTHORITIES HAVING JURISDICTION. w 3. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED Q z PERMITS AND ARRANGE ALL REQUIRED INSPECTIONS. 4. ALL CONTRACTORS SHALL EXAMINE THE SITE AND REVIEW THE DRAWINGS O I— AND SPECIFICATIONS PRIOR TO SUBMITTING A PROPOSAL. ALL ELEVATIONS _- SHALL BE VERIFIED AT THE JOB SITE. 5. CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION OF ALL EXISTING UTILITIES IN FIELD PRIOR TO STARTING WORK. } 6• PLUMBING CONTRACTOR SHALL COORDINATE HIS / HER WORK WITH OTHER I' HOT & COLD WATER & GAS PIPING PLAN CONTRACTORS IN ESTABLISHING PIPE RUNS AND SPACE CONDITIONS. i 7. ALL PIPING TO BE CONCEALED IN HUNG CEILINGS, CHASES AND FURRED SPACES. SCALE: 1 4" = 1'-0" 8. THE DRAWINGS AS PREPARED ARE DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS CONSTRUCTION OF THE PROJECT AND THE WORK OF THE TRADES WILL PERMIT. EQUIPMENT LOCATIONS INDICATED ARE APPROXIMATE. COORDINATE EXACT LOCATIONS AND REQUIRED CLEARANCES WITH EQUIPMENT SUPPLIER AND ALL TRADES PRIOR TO INSTALLATION. 9. REFER TO EQUIPMENT SCHEDULE AND EQUIPMENT SPECIFICATIONS FOR ° "' EXACT LOCATIONS OF PLUMBING CONNECTIONS. I , ' 10. ALL PREP AREA AND SERVING AREA EQUIPMENT WILL BE FURNISHED AND �i 0O I , INSTALLED EXCEPT AS NOTED, (SEE 'K' SHEETS, EQUIPMENT SCHEDULES). z m EQUIPMENT WILL BE FURNISHED WITH TRIM AND FAUCETS, EXCEPT AS O --� ( ` NOTED. PLUMBING CONTRACTOR SHALL PROVIDE ALL ROUGH-IN TRAPS AND f�R I MAKE ALL FINAL CONNECTIONS. U 11. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL GAS PIPING AND O 4 •�� .__ ` ' MAKE ALL FINAL CONNECTIONS. GAS PIPING TO BE SCHEDULE 40 BLACK J -i j E _. STEEL PIPE AND BANDED MALLEABLE IRON FITTINGS. m 6 = r 12. THIS CONTRACTOR SHALL PROVIDE AND INSTALL ALL PIPE HANGERS, AND SUPPORTS IN ACCORDANCE WITH THE LOCAL APPLICABLE CODES. L%_ `- f 13. PLUMBING CONTRACTOR TO PROVIDE BACKFLOW PREVENTERS AT ALL ' COFFEE MAKERS, OVENS, DIPPING WELLS, ICE MAKER AND ALL OTHER - . EQUIPMENT AS REQUIRED BY CODE. Y 14. PLUMBING CONTRACTOR TO PROVIDE TRAP PRIMERS OR TRAP SEAL ON ALL I FLOOR DRAINS AS PER APPLICABLE CODE LLJ 15. ALL ROOF PENETRATIONS SHALL BE AT THE CONTRACTOR'S EXPENSE. COORDINATE WITH OWNER'S ROOFING CONTRACTOR SO AS NOT TO VOID ALL EXISTING ROOF WARRANTIES. 16. ANY CUTTING OR PATCHING NECESSARY TO PERMIT THE INSTALLATION OF SUPPLY SYMBOL LIST ANY WORK UNDER THIS CONTRACT SHALL BE THE RESPONSIBILITY OF THIS } GAS COCK CONTRACTOR. 17. ALL UNDERGROUND WATER LINES SHALL BE TYPE "K" COPPER TUBING WITH ---------- F.C.W. - FILTERED COLD WATER 1/2" THICK ARMAFLEX INSULATION. ----- C.W. - COLD WATER 18. ALL SANITARY UNDER SLAB PIPING SHALL BE PVC. _- 19. ALL ABOVE SLAB VENT & DRAINAGE PIPING SHALL BE CAST IRON OR - ------- H.W. - HOT WATER COPPER. (PVC CAN BE USED IF ALLOWED BY LOCAL CODES). SH�� G GAS PIPING INSIDE FOR APPLIANCES 20. IF WATER FILTRATION SYSTEM IS USED, BRANCH OFF MAIN LINE. SEE WATER FILTRATION SHEET FOR MORE DETAILS. RG GAS PIPING OVER ROOF FOR HVAC I7 W 21. ENTIRE INSTALLATION SHALL BE GUARANTEED FREE OF DEFECTS AND z. -- -- - MIXED HOT/COLD WATER PIPING CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DEFECTIVE MATERIALS '"'� " TEMPERING VALVE OR EQUIPMENT AT NO COST TO THE OWNER FOR A PERIOD OF ONE YEAR H.B. HOSE BIBB FROM THE DATE OF ACCEPTANCE BY ENGINEER. am .. H.V.A.C. HEAT VENT AND AIR CONDITIONING UNIT 22• ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT /OWNER. Ti JOB'S: D160 A.F.F. ABOVE FINISH FLOOR 23. PLUMBING CONTRACTOR TO PROVIDE AERATORS ON ALL HAND SINKS AND DATE: O J , U.N.O. UNLESS NOTED OTHERWISE LAVATORIES THROUGHOUT THE FACILITY. / /- C.M. V. LAN _` ', HAND SINK (EXISTING) ` NOTE: F'EE AND FIELD TEAM TO DETERMINE IF EXISTING BACK ROOM EQUIPMENT AND COLD/DRY STORAGE CAPACITIES CONFORM TO CURRENT STANDARDS. TIE INTO VENTIle ', LINES,TYP PREP 1 12" .n .U., KIT. i AREA F OFFICE `�} I (EXISTING) ., HALL _ EXIST. ----� ) COL Ili( II ----II ----i � �e" EXISTING i I'llI'lli I II (EXISTING) > , \ ----�L------J � � I _ II I P�� r f I P1 0 NEW TIE INTO EXISTING i I H.W. WASTE LINES ` F.C.O. z E u sw EXISTING F.D I RESTROOM SERVING u N H.O.I N >> I ----------- - I -------_-- AREA - 1 _ ----------- - ------- ir -�-- ------ --- -- --------- EXISTING - O �i ,i H.O. �/ 5-3' 7' � i i FRONT LINE CHASE IN KNEE WALL OF FRONT RESTROOM �'�� i�i i� LINE. NOTE: KNEE WALL IS PART OF MILLWORK PACKAGE, NOT FIELD BUILT. LOCATION OF SUPPLY & WASTE SERVICE TO FRONT LINE IS i� Nyi IS LOCATED ON THE SERVICE SIDE OF THIS WALL. I< kk` y OM=M C((l r i 6 AB,� M}4 SALES PLUMBING IN THIS STORE IS EXISTING. REUSE WHERE POSSIBLE. UPGRADE TO "MEET qgy k 44 PR .:: a;l ALL APPLICABLE STATE AND LOCAL CODES. vw eVN pp AREA CONNECT NEW PLUMBING TO EXISTING. j PLUMBING FIXTURE SCHEDULE MARK DESCRIPTION WASTE VENT COLD HOT WATER WATER * P 1 BACK BAR SINK 1 1/2" 1 1/2" 1/2" 1/2" Li SINK PROVIDED AS PART OF EQUIPMENT PACKAGE - o PLUMBER TO MAKE FINAL CONNECTIONS. r7 O co EXISTING Z m GEN VESTIBULE GENERAL NOTES 0 LJ 1. THESE DRAWINGS ARE FOR SCHEMATIC DESIGN ONLY. IT IS UP TO EACH > 0 D I INDIVIDUAL DESIGNER TO SPECIFY AND ENGINEER THESE SYSTEMS FOR SITE 1 I SPECIFIC LOCATIONS. 2. ALL WORK SHALL COMPLY WITH ALL LOCAL AND STATE CODES AND - I AUTHORITIES HAVING JURISDICTION. �Z 3. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED w ~ PERMITS AND ARRANGE ALL REQUIRED INSPECTIONS. o z ! I 4. ALL CONTRACTORS SHALL EXAMINE THE SITE AND REVIEW THE DRAWINGS AND SPECIFICATIONS PRIOR TO SUBMITTING A PROPOSAL. ALL ELEVATIONS SHALL BE VERIFIED AT THE JOB SITE. 5. CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION OF ALL EXISTING UTILITIES IN FIELD PRIOR TO STARTING WORK. SOIL, WASTE, VC Q�+. VENT PLAN 6• PLUMBING CONTRACTOR SHALL COORDINATE HIS / HER WORK WITH OTHER I CONTRACTORS IN ESTABLISHING PIPE RUNS AND SPACE CONDITIONS. 7. ALL PIPING TO BE CONCEALED IN HUNG CEILINGS, CHASES AND FURRED SPACES. SCALE: 1/4" = 1 -0" 8. THE DRAWINGS AS PREPARED ARE DIAGRAMMATIC BUT SHALL BE FOLLOWED F.S. = W/AIR GAP - SAFE WASTE AS CLOSELY AS CONSTRUCTION OF THE PROJECT AND THE WORK OF THE TRADES WILL PERMIT. EQUIPMENT LOCATIONS INDICATED ARE APPROXIMATE. F.D. W/AIR GAP CUP COORDINATE EXACT LOCATIONS AND REQUIRED CLEARANCES WITH EQUIPMENT SUPPLIER AND ALL TRADES PRIOR TO INSTALLATION. T.... , 9. REFER TO EQUIPMENT SCHEDULE AND EQUIPMENT SPECIFICATIONS FOR EXACT LOCATIONS OF PLUMBING CONNECTIONS. 10. ALL PREP AREA AND SERVING AREA EQUIPMENT WILL BE FURNISHED AND 0 INSTALLED EXCEPT AS NOTED, (SEE 'K' SHEETS, EQUIPMENT SCHEDULES). Or_ WILL BE FURNISHED WITH TRIM AND FAUCETS, EXCEPT AS p _: NOTED. PLUMBING CONTRACTOR SHALL PROVIDE ALL ROUGH-IN TRAPS AND = MAKE ALL FINAL CONNECTIONS. Q 11. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL GAS PIPING AND O ` O ~ ~ "D I MAKE ALL FINAL CONNECTIONS. GAS PIPING TO BE SCHEDULE 40 BLACK / ! STEEL PIPE AND BANDED MALLEABLE IRON FITTINGS. n ^�,- 12. THIS CONTRACTOR SHALL PROVIDE AND INSTALL ALL PIPE HANGERS, AND O L L r_ SUPPORTS IN ACCORDANCE WITH THE LOCAL APPLICABLE CODES. - % LIJf 13. PLUMBING CONTRACTOR TO PROVIDE BACKFLOW PREVENTERS AT ALLQo - COFFEE MAKERS, OVENS, DIPPING WELLS, ICE MAKER AND ALL OTHER €- - EQUIPMENT AS REQUIRED BY CODE. e 14. PLUMBING CONTRACTOR TO PROVIDE TRAP PRIMERS OR TRAP SEAL ON ALL I FLOOR DRAINS AS PER APPLICABLE CODE SYMBOL LIST 15• ALL ROOF PENETRATIONS SHALL BE AT THE CONTRACTOR'S EXPENSE. COORDINATE WITH OWNER'S ROOFING CONTRACTOR SO AS NOT TO VOID ALL SANITARY WASTE PIPING BELOW SLAB EXISTING ROOF WARRANTIES. 16. ANY CUTTING OR PATCHING NECESSARY TO PERMIT THE INSTALLATION OF — w GREASE WASTE PIPING BELOW SLAB ANY WORK UNDER THIS CONTRACT SHALL BE THE RESPONSIBILITY OF THIS h VENT PIPING BELOW SLAB CONTRACTOR. I 17• ALL UNDERGROUND WATER LINES SHALL BE TYPE "K" COPPER TUBING WITH ---V--- VENT PIPING ABOVE SLAB 1/2" THICK ARMAFLEX INSULATION. GREASE TRAP 18. ALL SANITARY UNDER SLAB PIPING SHALL BE PVC. F.C.O. FLOOR CLEAN OUT 19. ALL ABOVE SLAB VENT & DRAINAGE PIPING SHALL BE CAST IRON OR -- COPPER. (PVC CAN BE USED IF ALLOWED BY LOCAL CODES). sH,EE , H.O. HUB OUTLET - W AIR GAP - SAFE WASTE 20. IF WATER FILTRATION SYSTEM IS USED, BRANCH OFF MAIN LINE. SEE WATER F.D. FLOOR DRAIN - W/AIR GAP CUP FILTRATION SHEET FOR MORE DETAILS. 'k 21. ENTIRE INSTALLATION SHALL BE GUARANTEED FREE OF DEFECTS AND F.S. FLOOR SINK - W AIR GAP - SAFE WASTE CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DEFECTIVE MATERIALS ` " V.R. VENT RISER OR EQUIPMENT AT NO COST TO THE OWNER FOR A PERIOD OF ONE YEAR :r j FROM THE DATE OF ACCEPTANCE BY ENGINEER. ro V.T.R. VENT THRU ROOF 22. ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT I.W. INDIRECT WASTE OWNER. JOB#: D1OO�n ,4 A.F.F. ABOVE FINISH FLOOR 23. PLUMBING CONTRACTOR TO PROVIDE AERATORS ON ALL HAND SINKS AND U.N.O. UNLESS NOTED OTHERWISE LAVATORIES THROUGHOUT THE FACILITY. DATE: 03/1 ./i PC#: 3303 C.M. V. c INCOMING COLD WATER LINE TO BE 1 — 1 /2" DIAMETER MINIMUM PER DUNKIN' BRANDS, INC. STANDARDS. BACKFLow µ PREVENTER 1" 3/4" 3/4„ qrBV 3/4" BV 3/4" 3/4" 1/2"El O BV FW BV O BV BV . FLUSH VAC VAC ; SERVICE ENTRANCE NOTE: STRAINER VALVE BKR BKR ''° va� CW FROM INCOMING WATER SERVICE OPTIONAL 1/2" 1/2" �'; cW BOOSTER PUMP __ L MCANN'S: 16-2173-DD WATER BOOSTER 3/4" W/ INTEGRAL PRESSURE GAUGE & BYPASS. TWIN FILTRATION SYSTEM ❑ VERIFY PUMP SPEC WITH NATIONAL ACCOUNTS 3M: DP ICE-260-S 3/4" VERIFY WATER FILTER SYSTEM SPEC L ; > _ / WITH NATIONAL ACCOUNTS ALL EXPOSED PLUMBING AND SUPPLIES ARE i. TO BE COPPER ALL EQUIPMENT WILL REQUIRE PLUMBER CUD FURNISHING BRAIDED SUPPLY LINES FROM r THE APPLIANCE BF PREVENTER TO THE BV EQUIPMENT. BFP BFP BV '' UTILITY WATER CONNECTIONSCM — RESTROOMS — SILL COCKS — 3—COMP SINK — IRRIGATION — DIPPER WELLS — HAND SINKS r — HOSE BIBB — COFFEE SPRAYERS , m pa j ICE MAKER ALL OVENS w - DD ITEM #494 DD ITEM #535k. JUST BAKED #552A BACK OF HOUSE BOH EQUIPMENT LAYOUT TYPICAL FOR NOTE: OVEN IS OPTIONAL IN THE b ALL COMBOS W DUNKIN' DONUTS SUPPORT AREA PRESENT AND AT ALL DUNKIN' DONUTS INDIVIDUAL STORES. QUANTITY & TYPES NOTE: PROVIDE A PRESSURE OF EQUIPMENT MAY VARY BASED ON REDUCING VALVE SET TO 40 PSI, DUNKIN' DONUTS FIXTURE LAYOUT. PRESSURE GAUGE & SHUT—OFF --�--------� w - - VALVE AT PLUMBING CONNECTION i:- TO ADAMATIC OVEN (TYP.) "d A• � F f � DUNKIN' DONUTS WATER SPECIFICATION & TREATMENT REQUIREMENTS CHARACTERISTIC DUNKIN DONUTS SPECIFICATION WATER TREATMENT SOLUTIONS %H UNITS IDEAL RANGE I LIMIT I I A WATER FILTER I B REVERSE OSMOSIS HARDNESS PPM 80-120 < 200 > 200 NA — FRONT LINE STATIONS BACK LINE STATIONS --�- -� - ALKALINITY PPM 70-110 0-150 > 150 NA 3/4" 3/4" TOTAL DISSOLVED S (IDS) PPM 100-175 < 250 NA > 250 � � � � LIDS 0 f pH pH 6.7-7.4 6.7-7.4 < 6.7 OR >7.4 NA _ I h7 i SODIUM PPM 0-20 < 40 > 40 NA VAC VAC VAC VAC VAC VAC BAR BKR BKR BKR BKR BKR >- cn WATER QUALITY CHLORIDE PPM 0 < 40 > 40 NA 0 m INSTALLATION CHECKLIST: CHLORAMINES PPM 0 0 > 0 NA w 1/2„ 3/8„ 3/8" 3/8" 3/8" 3/8" CHLORINE PPM 0 0 > 0 NA � O � FRONT OF HOUSE (FOH) TURBIDITY NTU 0-1 < 1 > 1 NA — ! ❑ COFFEE EQUIPMENT (FRONT LINE) ❑ COFFEE EQUIPMENT (DRIVE THRU) PRESSURE PSI > 60 PSI BOOSTER PUMP IS REQUIRED w p � i ❑ WATER SPRAYERS * IN ADDITION TO THE ABOVE SPECIFICATIONS, WATER MUST MEET NSF42 AND NSF53 STANDARDS ! - - —.-- ❑ ESPRESSO PPM = PARTS PER MILLION O i I i 100 PPM = 5.8 GRAINS PER GALLON z —-I .-. ❑ HOT CHOCOLATE NOTE: PROVIDE A ❑ ICED COFFEE / TEA NOTES: PRESSURE REDUCING BV BV BV BV BV VALVE AT ESPRESSO m# .. 1) PRIOR TO CONSTRUCTION, GC SHALL PROVIDE A WATER QUALITY TEST, PERFORMED IN THE CITY MACHINE BACK OF HOUSE (BOH) IN WHICH THE STORE WILL BE RECEIVING WATER. TESTING WILL BE DONE ON A LIVE LINE CONNECTED BFP BFP BFP BFP BFP TO THE SAME SUPPLY LINE FEEDING THE STORE. e ❑ ICE MAKERS (N/A RO SYSTEMS) ❑ BAXTER 2) UPON RECEIPT OF THE WATER QUALITY TEST, THE GC SHALL PROVIDE A FILTRATION SYSTEM OR RO SYSTEM THAT WILL TREAT THE INCOMING WATER TO ALLOW IT TO MEET THE ❑ BLODGETT REQUIREMENTS IN THE TABLE ABOVE. ❑ ADAMATIC BV BV BFP ._ 3) UPON COMPLETE OF CONSTRUCTION, GC SHALL SUBMIT A SECOND WATER QUALITY TEST TAKEN D I ❑ PROOFER FROM A TREATED WATER OUTLET TO VERIFY THE PROPER WATER QUALITY IS BEING ACHIEVED. # ` t L SOFTENING ESPRESSO TWIN COFFEE SINGLE COFFEE ISLAND HOT ICED COFFEE T CARTRIDGE MACHINE BREWER BREWER OASIS WINTER BREWER Q "� DD ITEM #96 DD ITEM #101P-3 DD ITEM #101PP-3 DD ITEM #200A BEVERAGE o SEPARATE PURCHASE OF A McCANNS BOOSTER PUMP IS DD ITEM #116 DD ITEM #108A Q �` SYMBOL LEGEND REQUIRED IN ALL STORES WITH TWO EXCEPTIONS: 1. STORES INSTALLING AN EVERPURE RO SYSTEM ARE NOT 00 I --- � REQUIRED TO PURCHASE THE PUMP, AS THERE IS A ALL EQUIPMENT SHOWN SHALL HAVE AIR GAP THAT MEETS ASSE 1022 OR PROVIDE AN AIR GAP - " DESCRIPTION SYMBOL BOOSTER PUMP INTEGRAL TO EVERPURE'S SYSTEM. �-- 2. STORES WITH AN INCOMING WATER PRESSURE DOCUMENTED FRONT OF HOUSE (INCLUDING DRIVE THRU) C :r TO BE GREATER THAN 60 P.S.I. ARE NOT REQUIRED TO COLD WATER PIPING (UNFILTERED) Oyy HAVE A BOOSTER PUMP INSTALLED. FOH EQUIPMENT LAYOUT TYPICAL FOR L1 1 'ALL COMBOS W/ DUNKIN' DONUTS r PRESENT AND AT ALL DUNKIN' DONUTS FILTERED WATER FW INDIVIDUAL STORES. QUANTITY & TYPES OF EQUIPMENT MAY VARY BASED ON RO WATER RO DUNKIN' DONUTS FIXTURE LAYOUT. NOTE: SEE HOT & COLD WATER RISER DIAGRAM FOR ADDITIONAL INFORMATION. { BALL VALVE H BV UNION S H LE E T STRAINER -- 0y CHECK VALVE N cV 3 M WATER FILTRATION SYSTEM . w BACKFLOW PREVENTER (VERIFY SYSTEM WITH OWNER) VACUUM BREAKER 07-31 -1 1 JOB#: D160O ^ DATE: 03/15, 6 PCB 3303L: C.M. V. LANC