HomeMy WebLinkAbout0080 WACHUSETT AVENUE - Health (2) �� �Gc0►uSe�' ���Ue i
-- -�_
II
.0
Town of Btarnstable P ft
Department of Health,Safety,and Environmental Services
UV Public Health Division Date
367 Main Street,Hyannis MA 02601
HARNErrABEA
Date Sclieduled C, d Y Time a? b_A, Fee Pd.
Soil Suitability Assessment for Sewage Disposal
Performed By: David A- Clark Witnessed By: CIpn p_- Harrington
.......................... ......................
.........................
..........
......:..L....'.:..... AT' 10 .E N E. L ..F.....O......_
...N.....
A... TION
LocationAddre90 W s Name Gera...l...
d......H.
. Doherty
Address41 Resevoir Road
80 Wachusett Avenue Farmington, CT 06032-2401
Assessor's Map/Parcel: . 0 63 Engineer s ame Eldredge, Quigley & Clark
NEW CONSTRUCTION REPAIR Telephone# 508-945-3965
Land Use _r e s i d ran ti-a 1 Slopes Surface Stones
Distances from: Open Water Body_11 Possible Wet Area ft Drinking Water Well ft
Drainage Way ft Property Line ft Other ft
SKETCH:(Street name,dimensions of lot,exact locations of test holes&perc tests,locate wetlands in proximity to holes)
-P).
Parent material(geologic) glacial c)i1twash Depth to Bedrock > 168"
Depth to Groundwater: Standing Water in Hole: Weeping from Pit Face no
Estimated Seasonal High Groundwater >168"
................... .............................. ............ ........................
............ ......
. .......... .........
b.L'* . .................................'S— A
..........DE TE IMNA L"'
. ...........I ]�i. ...................
.....................
................ ....................I......... . ................... ......
Method Used:
Depth Observed standing in obs.hole: in. Depth to soil mottles: 4811 in.
Depth to weeping from side of obs.hole: in. Groundwater Adjustment
Index Well# -Reading Date: Index Well level...--- Adj.factor Adj.Groundwater Level
.......... .....
..................................... .......
.............
..................... .........
............ : 8 (Iff e:
........ .... ...................
...........................PERCOLATION............................
................ ...... ........
.......11,.............................
..................................................... ................I..........................
Observation could
Hole# Time at 9" not
main aln
Depth of Perc 120" Time at 6"
Start Pre-soak Time @ Time(9'-V)
End Pre-soak
Rate Min./inch <
Site Suitability Assessment: Site Passed X Site Failed: Additional Testing Needed(Y/N)
Original: Pua';w Division Observation Hole Data To Be Completed on Back
Copy: Applicant
r -
DEEP OBSEI� ATIOIri Hl7LE T.C,1G II01e#
Depth from Soil Horizon Soil Texture Soil Color Soil Other
Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Doulderes.
%
0 — 8" A loamy sar 10YR 5/3
0 - 48" B loamy 10YR 6/6
48 -96" C1 silt. nArn_ 56Y 6/1 yes 10 YR 5/6
96 - 15 " C2 coarse 10YR 8/4 bolders & cobbles
qana
8 13.2
DEEP 0 SER'�ATIQN HOLE Lt�G Hole#
Depth from ( Soil Horizon I Soil Texture Soil Color Soil Other
Surface(in.) (USDA) (Munsell) Mottlin
g (Structure,Stones,l3oulderes.
Cmsiqslency.%G
0 -16" A loamy sand10YR 5/4
16-48" g loamy 10YR 5/6
4?8-84" loamy sand10YR 6/6
8 Silt loam56 Y 6/1 few
120- coarse 10YR 8/4
10 14
.......DEI•P (J3SERVAT101�i HOLE LAG Hole#`
Depth from Soil Horizon Soil Texture Soil Color Soil Other
' -I
Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,1oulderes.
%
DLEP OBSERVATION HALE LC�G Hole
.... .. .::.... .:.. ..
Depth from Soil Horizon Soil Texture Soil Color Soil Other
Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Doulderes.
%
Flood Insurance Rate Map;
Above 500 year flood boundary No— Yes X
Within 500 year boundary No X Yes
Within 100 year flood boundary No X Yes
Depth of Naturally Occurring Pervious Material
Does at least four feet of naturally occurring pervious material exist in all areas observed throughout the
area proposed for the soil absorption system? Yes
If not,what is the depth of naturally occurring pervious material?
Certification
I certify that on 7/9 5 (date)I have passed the soil evaluator examination approved by the
Department of Environmental Protection and that the above analysis was performed by me consistent will]
the required training,expertise and experience described in 310 CMR 15.017.
Signature Date