HomeMy WebLinkAbout0255 SHOOTFLYING HILL RD - Health 255 Shootflyine, Hill Road
West Barnstable
A = 214 - 14 - 003
i
Commonwealth of Massachusetts a IV- 01q- 003
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address N
Zachary Hunter
Owner Owners Name
information is bl t t Barnstable / L
required'For every Wes V Ma 02668 5/5/2020
page. Cityfrown State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
Important:When A. Inspector Information j i�s o`�
filling out forms
on the computer, Sean M. Jones
use only the tab
key to move your Name of Inspector
cursor-do not S.M.Jones Title V Septic Inspection
use the return __..._....._. ....._
key. Company Name
74 Beldam Lane
Co
� Company Address
Centerville Ma 02632
Cityfrown State Zip Code
774-248-4850 smjonestitle5@gmail.com, S14522
sean@smjonestitle5.com License Number
B. Certification
I certify that: I am a DEP approved system inspector in full compliance with Section 15.346 of Title 5
(310 CMR 16.000); 1 have personally inspected the sewage disposal system at the property address
listed above; the information reported below is true, accurate and complete as of the time of my
inspection; and the inspection was performed based on my training and experience in the proper function
and maintenance of on-site sewage disposal systems. After conducting this inspection I have determined
that the system:
1. ® Passes
2. ❑ Conditionally Passes
3. ❑ Needs Further Evaluation by the Local Approving Authority
4. ❑ Fails
5/5/2020
Inspector's Signature
�submithis
Date
The system inspector s a inspection report to the Approving Authority (Board
of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of
10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate'
regional office of the DEP. The original form should be sent to the system owner and copies sent to
the buyer, if applicable, and the approving authority.
Please note: This report only describes conditions at the time of inspection and under the
conditions of use at that time.This inspection does not address how the system will perform
In the future under the same or different conditions of use.
t5insp.doc•rev.MAW Tdte 5 Official Inspection Form.Subsurface Sewage Disposal System•Page t of is
Comrhoriwealth'of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
-� 255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owner's Name
infbrmarequire for
is West Barnstable Ma 02668
required for every 5/5/2020
page. City/Town State Zip Code Date of Inspection
C. Inspection Summary
Inspection Summary: Complete 1, 2, 3,or 5 and all of 4 and 6.
1) System Passes: ;
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
The property located at 255 Shootflying Hill Rd is served by a Title V septic system consisting of a
1000 gallon septic tank, distribution box and 5 Infiltrators. Although the system was found to be in
proper working condition at the time of inspection this report does not guarantee future performance
under similar or increased usage.
2) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Pass"section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes", "no"or"not determined"(Y, N, ND)for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old"or the septic tank(whether metal or not) is structurally
unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass
inspection if the existing tank is replaced with a complying septic tank as approved by the Board of
Health.
'A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND(Explain below):
Mnsp.doc•rev.7 26M1® Title 5 official Inspection Form.Subsurface Sewage Disposal System-Page 2 of 16
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootfiying Hill Road
Property Address
Zachary Hunter
Owner Owner's Name
information is required for every West Barnstable Ma 02668 5/5/2020
page. City/Town State Zip Code Date of inspection
C. Inspection Summary (cont.)
2) System Conditionally Passes(cunt.):
❑ Pump-C-hamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
❑ Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND(Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ NO(Explain below):
❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND(Explain below):
i
❑ The system required pumping more than 4 times a year due to broken or-obstructed pipe(s).The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ NO(Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below):
3) Further Evaluation is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
a. System will pass unless Board of Health determines In accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect pudli6 health,
safety and the environment:
t5insp,coc•rev.7 AMI8 Title 5 Official Inspection Form.Suosurrace Sevtage DISOMI Syslem•Page 3 of 18
Commonwealth of Massachusetts
r
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address
Zachary Hunter _
Owner Owner's Name
information is required for every West Barnstable Ma 02668 5/5/2020
page. Cityrrown State Zip Code Date of Inspection
C. Inspection Summary (cont.)
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
b. System will fail unless the Board of Health(and Public Water Supplier, if any)
determines that the system is functioning In a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
Y
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well's*.
Method used to determine distance:
•'This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must
be attached to this form.
c. Other:
�I
4) System Failure Criteria Applicable to All Systems:
You must Indicate"Yes" or"No"to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
t5insp.doc-rev,712612018 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System-Page 4 of 18
Commonwealth of Massachusetts
Title 5 official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owner's(dame
infonnatrequired
is West Barnstable Ma 02668 5/5/2020
required for every
page. Cityfrown State Zip Code Date of Inspection
C. Inspection Summary (cunt.)
4) System Failure Criteria Applicable to All Systems: (cont.)
Yes No
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6"below invert or available volume is less
than '/day flow
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply
well.
❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes If the well water analysis,performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered.A copy of the analysis
and chain of custody must be attached to this forma
® The system is a cesspool serving a facility with a design flow of 2000 gpd-
10,000 gpd.
❑ ® The system falls. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails.The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
5) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 16,000 gpd.
For large systems,you must indicate either"yes"or"no"to each of the following, in addition to the
questions in Section CA.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection
Area—IWPA)or a mapped Zone II of a public water supply well
t5insp.ox-rev.7126MI8 Title 5 Official Inspection Form:Subsurface Sewage Disposal system-Page 5 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owner's Name
information is West Barnstable Ma 02668 5/5/2020
required for®very
page, Cityrrown State Zip Code Date of Inspection
C. Inspection Summary (cons)
If you have answered"yes"to any question in Section C.5 the system is considered a significant
threat, or answered"yes"to any question in Section CA above the large system has failed. The
owner or operator of any large system considered a significant threat under Section C.5 or failed
under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner
should contact the appropriate regional office of the Department.
6. You must indicate"yes"or"no"for each of the following for all inspections:
Yes No
® ❑ Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
® ❑ Has the system received normal flows in the previous two week period?
® ® Have large volumes of water been introduced to the system recently or as part of
this inspection?
® ❑ Were as built plans of the system obtained and examined?(If they were not
available note as N/A)
® ❑ Was the facility or dwelling inspected for signs of sewage back up?
Z ❑ Was the site inspected for signs of break out?
® ❑ Were all system components, excluding the SAS, located on site?
® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
ED ❑ Was the facility owner(and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System(SAS)on the site has
been determined based on:
® ❑ Existing information. For example, a plan at the Board of Health.
❑ Determined in the field(if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable)(310 CMR 15.302(5))
�I
t5litep.doo•rev.712601i ll Title 5 Official Inspection Form:Subsurface Sewage Oisposat System•Page 6 or 16
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address _.....,.,,_,.
Zachary Hunter
Owner Owner's Name
Information is required for every West Barnstable Ma 02668 5/5/2020
page, Cityrrown State Zip Code Date of Inspection
D. System Information
1. Residential Flow Conditions:
Number of bedrooms(design): 3 Number of bedrooms(actual): 3
DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms): 330 gpd
Description:
i
Number of current residents: 2
Does residence have a garbage grinder? ❑ Yes ® No
Does residence have a water treatment unit? ❑ Yes ® No
If yes, discharges to:
Is laundry on a separate sewage system? (include laundry system inspection ❑ Yes ® No
information in this report)
Laundry system inspected? ❑ Yes ® No
Seasonal use? ❑ Yes ® No
Water meter readings, if available(last 2 years usage(gpd)):
Detail:
Sump pump? ❑ Yes ® No
Last date of occupancy: current
Date
t5insp.doc rev.7MMI8 Title 5 Offidal Inspection Form.Subsurface Sewage Disposal System-Pegs 7 or 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
k
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
v255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owner's Name
Information Is required'for every West Barnstable Ma 02668 5/5/2020
__. _.
page. Cityffown State Zip Code Date of Inspection
D. System Information (cont.)
2. Commercial/Industrial Flow Conditions:
Type of Establishment:
Design flow(based on 310 CMR 15.203): ---- - -
Gallons per day(gpd)
Basis of design flow(seats/persons/sq.ft., etc.):
Grease trap present? ❑ Yes ❑ No
Water treatment unit present? ❑ Yes ❑ No
If yes, discharges to:
Industrial waste holding tank present? ElYes [INo
Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No
Water meter readings, if available: - ----�— ----
Last date of occupancy/use: Date
Other(describe below):
3. Pumping Records:
Source of information: -
Was system pumped as part of the inspection? ❑ Yes ® No
If yes, volume pumped:
gallons
How was quantity pumped determined? - -
Reason for pumping: ............
..............
t5insp.doc•fev.71Y MIS Title 5 Otfiaa]tnspection Form:Subsudaa3 Sewage Disposal System•Pape 8 of 18
r
Commonwealth of Massachusetts
-_ Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owners Name
information is required fo--every West Barnstable Ma 02668 5/5/2020
page. Cityfrown State Zip Code Date of inspection
D. System Information (coot.)
4. Type of System:
® Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
I
❑ Shared system(yes or no)(if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology.Attach a copy of the current operation and
maintenance contract(to be obtained from system owner)and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other(describe):
....._..
Approximate age of all components, date installed (if known)and source of information.
original system installed 1997
Were sewage odors detected when arriving at the site? ❑ Yes ® No
5. Building Sewer(locate on site plan):
Depth below grade: 1.5
feet
Material of construction:
❑cast iron ®40 PVC ❑ other(explain):
Distance from private water supply well or suction line: feet
Comments(on condition of joints, venting, evidence of leakage, etc.):
Joints in good condition, no leakage, vented through roof.
t5insp.doc rev-7rAW18 Tate 5 official Inspection Form.sosurtaw Sewage oismal system•Pege 9 et 16
Commonwealth of Massachusetts
_ - = Title 5 official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments.
255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owner's Name
information is West Barnstable Ma 02668 5/5/2020
re
quired for every Cityrrown
State Zip Code Date of Inspection
D. System Information (cont.)
6. Septic Tank(locate on site plan):
Depth below grade: fleet
Material of construction:
Z concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain)
If tank is metal, list age: years
Is age confirmed by a Certificate of Compliance?(attach a copy of certificate) ❑ Yes ❑ No
1500 gallons
Dimensions; ------------------
'
Sludge depth: S",
Distance from top of sludge to bottom of outlet tee or baffle
3'
Scum thickness 2." -
Distance from to of scum to to of outlet tee or baffle 7" .....................
..................
sta ce m p p
0'"
Distance from bottom of scum to bottom of outlet tee or baffle 1 1
How were dimensions determined? Opened covers and took
measurements
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Tank does not need to be cleaned now but should be done soon and again every 2 years fior proper
maintenance.water level was even with outlet, tank was not leaking and was structurally sound.
t5fnsp,dac•rev.7t26M18 Title 5 Official inspection Fonm.SUbsutleee Sewage Disposal System•Pape 10 of 18
Commonwealth of Massachusetts
U
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootflying Hill Road _
Property Address
Zachary Hunter
Owner Owner's Name
information is required fog every West Barnstable Ma 02668 5/5/2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
7. Grease Trap(locate on site plan):
Depth below grade: feet
Material of construction:
❑concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain):
Dimensions: —
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping: path - -
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,.
liquid levels as related to outlet invert, evidence of leakage, etc.):'
a
..�.............
8. Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
❑concrete ❑ metal ❑fiberglass ❑polyethylene ❑other(explain):
Dimensions:
Capacity:
gallons
Design Flow: gallons per day
t5ft,doc•rev.7r86WS Title 6 Official Inspection Form;SUbsurtaw Sewage Disposal System•Pale 11 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
a
` 255 Shootflying Hill Road
................
Property Address
Zachary Hunter
Owner Owner's Name
information is.
required for every West Barnstable Ma 02668 5/5/2020
page. City/Town State Zip Code Date of Inspection
D. System Information (coot.)
8. Tight or Holding Tank(cont.)
Alarm present: ❑ Yes ❑ No
Alarm level: - - — -- Alarm in working order: ❑ Yes ❑ No
Date of last pumping: Date
Comments(condition of alarm and float switches, etc.):
...........
_..
"Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No
9. Distribution Box(if present must be opened)(locate on site plan):
Depth of liquid level above outlet invert 0"-- - - --
Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
Distribution box was video inspected and found level and in good condition with no rot. Water level
was even with outlet invert with no signs of past backup.
Wnsp.doc•rev.7t26 018 Title 6 Official Inspection Form Subsudece Sewage Disposal System•Page 12 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owners Name
information is required for every West Barnstable Ma 02668 5/5/2020 City/Town
page. State _ Zip Code Date of Inspection
D. System Information (coat.)
10. Pump Chamber(locate on site plan):
Pumps in working order: ❑ Yes ❑ No`
Alarms in working order: ❑ Yes ❑ No`
Comments(note condition of pump chamber, condition of pumps and appurtenances, etc.):
I �
`If pumps or alarms are not in working order, system is a conditional pass.
11. Soil Absorption System (SAS)(locate on site plan, excavation not required):
If SAS not located, explain why:
Type:
❑ leaching pits number:
leaching chambers number: 5 Infiltrators
❑ leaching galleries number:
❑ leaching trenches number, length:.
❑ leaching fields number, dimensions:
❑ overflow cesspool number:
❑ innovative/alternative system
Type/name of technology:
tbinsp: •rev.TJ26fZ018 Tine 5 official Inspection Form Subsurface Sewage Disposal System•Page 13 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System_Form-Not for Voluntary Assessments
' 255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owner's Name
information is West Barnstable Ma 02668 5/5/2020
required for every
page. City(Town State Zip Code Date of Inspection
D. System Information (cont.)
11. Soil Absorption System(SAS) (cont.)
Comments(note condition of soil, signs of.hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
Leaching facility was video inspected and was found with 3"standing water and no signs of past
hydraulic overloading
....... ..... ..................._.... ...._.... . ................................................................................... ........... . .............................. . .......
12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number and configuration
Depth—top of liquid to inlet invert --
Depth of solids layer --
Depth of scum layer
Dimensions of cesspool
Materials of construction
Indication of groundwater inflow ❑ Yes ❑ No
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
15insp.doc-my.7126=18 Title 5 Official inspection Form.Subsurface Sewage Oisposal System-Page 14 of 18
r
Commonwealth of Massachusetts
Title 5 official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owner's Name
Information is required for every west Barnstable Ma _ 02668 5/5/2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
13. Privy(locate on site plan):
Materials of construction:
Dimensions
Depth of solids --.
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
I
ISInsp.doc-rev.MAWS Title 5 Official Inspection Form:Suoswface Sewage Disposal System•Page 15 of 19
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal,System Form-Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner owner's Name
information is West Barnstable Ma 02668 5/5/2020
required for every _,_ _— _ _ _._._...._..._..._ecti
page, Cltylrown State Zip Code Date of Inspection
D. System Information (coat.)
14. Sketch Of Sewage Disposal System:
Provide a view of the sewage disposal system, including ties to at least two permanent reference
landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters
the building. Check one of the boxes below:
® hand-sketch in the area below
❑ drawing attached separately
I
�-
/- � 3 /
17
37
A3 L/o+c-
t5mV doc•rev,712612018 Title 5 oNbal inspection Forth Subsurface Sewage Disposal System+Page 16 or 18
f '
Commonwealth of Massachusetts
_ _ — I Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shootflying Hill Road
Property Address
Zachary Hunter
Owner Owner's Name
information is required for every West Barnstable Ma 02668 5/5/2020
page. Citfrrown State Zip Code Date of Inspection
D. System Information (cont.)
15. Site Exam:
❑ Check Slope
❑ Surface water
❑ Check cellar
❑ Shallow wells
Estimated depth to high ground water: 12'+
feet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed: Date
❑ Observed site(abutting property/observation hole within 150 feet of SAS)
❑ Checked with local Board of Health-explain:
❑ Checked with local excavators, installers-(attach documentation)
❑ Accessed USGS database-explain:
You must describe how you established the high ground water elevation:
Groundwater was established by accessing town of Barnstable groundwater contour maps.
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
t5insp.dac•rev.71262018 TiUS 5 Official Inspection form Subsurface Sewage Disposal System•Page 17 or 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
255 Shoofflying Hill Road
Property Addr
ess
Zachary Hunter
Owner Owner's Name
information is West Barnstable Ma 02668 5/5/2020
required for every
page. City/Town State Zip Code Date of Inspection
E. Report Completeness Checklist
PP
Complete all applicable
ble sections of this form inclusive of:
p
® A. Inspector Information: Complete all fields in this section.
® B. Certification: Signed& Dated and 1, 2, 3, or 4 checked
® C. Inspection Summary:
1,2, 3, or 5 completed as appropriate
4 (Failure Criteria)and 6(Checklist)completed
® D. System Information:
For 8: Tight/Holding Tank—Pumping contract attached
For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached
For 15: Explanation of estimated depth to high groundwater included
15insp.dnc•rev.71287018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 18 or 18
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
_ Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
' M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Own is ame
information is U15+73ay.in3-f-a
required for VC Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
'�" �I 2114 01 H-003
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
Important: A. General Information
When filling out
forms on the
computer,use 1. Inspector:
only the tab key
to move your Robert Paolini
cursor-do not Name of Inspector
use the return
key. Capewide Enterprises,LLC.
Company Name
P.O.Box 763
Company Address
Centerville Ma. 02632
City/Town State Zip Code
(508)428-4028 S14454
Telephone Number License Number
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information reported below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of
Title 5.(310 CMR 15.000). The system:
® Passes ❑ Conditionally Passes ❑ "ils
❑ Needs Further Evaluation by the Local Approving Authority
v 4
12/23/2010
InspectorsXignat Date
The system inspector shall submit a copy of this inspection report to the Approving Authority(Board
of Health or DEP)within 30 days of completing this inspection. If the system is'a shared s,yste.m:or
has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the
report to the appropriate regional office of the DEP. The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use
at that time.This inspection does not address how the system will perform in the future under
the same or different conditions of use.
t5ins-11/10 Title 5 Official Inspection Form:Subsurface Sewag isposal System-Page 1 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
Inspection Summary: Check A,B,C,D or E/always complete all of Section D
A) System Passes:
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist.Any failure criteria not evaluated are
indicated below.
Comments:
The septic system is in proper working order at the present time.
B) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Pass" section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes", "no" or"not determined" (Y, N, ND)for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old* or the septic tank (whether metal or not) is
structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System
will pass inspection if the existing tank is replaced with a complying septic tank as approved by the
Board of Health.
*A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 2 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
B. Certification (cont.).
B) System Conditionally Passes (cont.):
❑ Observation of sewage backup or break out or high static water'level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
C) Further Evaluation is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 17
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
°M 255 Shootfl in Hill Rd.
Y 9
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
2. System will fail unless the Board of Health (and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS)-and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well**..
Method used to determine distance:
**This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must
be attached to this form.
3. Other:
D) System Failure Criteria Applicable to All Systems:
You must indicate "Yes" or"No" to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less
than %day flow
t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 17
Commonwealth of Massachusetts
. Title In n F te5Inspection Form
0
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
^M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
Yes No
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well.
❑ ® . Any portion of a cesspool or privy is within 50 feet of a private water supply
well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered.A copy of the analysis
and chain of custody must be attached to this form.]
❑ ® The system is a cesspool serving a facility with a design flow of 2000gpd-
10,000gpd.
❑ ® The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
E) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the
questions in Section D.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection
Area— IWPA)or a mapped Zone II of a public water supply well
If you have answered "yes"to any question in Section E the system is considered a significant threat,
or answered "yes" in Section D above the large system has failed. The owner or operator of any large
system considered a significant threat under Section E or failed under Section D shall upgrade the
system in accordance with 310 CMR 15.304. The system owner should contact the appropriate
regional office of the Department.
t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 17
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
^M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
C. Checklist
Check if the following have been done.You must indicate"yes"or"no" as to each of the following:
Yes No
® ❑ Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
® ❑ Has the system received normal flows in the previous two week period?
® ❑ Have large volumes of water been introduced to the system recently or as part of
this inspection?
® ❑ Were as built plans of the system obtained and examined? (If they were not
available note as N/A)
® ❑ Was the facility or dwelling inspected for signs of sewage back up?
® ❑ Was the site inspected for signs of break out?
® ❑ Were all system components, excluding the SAS, located on site?
® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
® ❑ Was the facility owner(and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System (SAS) on the site has
been determined based on:
® ❑ Existing information. For example, a plan at the Board of Health.
❑ ® Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable) [310 CMR 15.302(5)]
D. System Information
Residential Flow Conditions:
Number of bedrooms (design): 3 Number of bedrooms (actual): 3
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330
t5ins•11110 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
D. System Information
Description:
Number of current residents: 2
Does residence have a garbage grinder? ❑ Yes ® No
Is laundry on a separate sewage system? [if yes separate inspection required] ❑ Yes ® No
Laundry system inspected? ® Yes ❑ No
Seasonaluse? ❑ Yes ® No
Water meter readings, if available last 2 years usage d NA
Detail:
Sump pump? ❑ Yes ® No
Last date of occupancy: 12/23/2010
Date
Commercial/Industrial Flow Conditions:
Type of Establishment:
Design flow(based on 310 CMR 15.203): Gallons per day(gpd)
Basis of design flow(seats/persons/sq.ft., etc.):
Grease trap present? ❑ Yes ❑ No
Industrial waste holding tank present? ❑ Yes ❑ No
Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No
Water meter readings, if available:
t5ins•11110 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 17
I
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
�M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Last date of occupancy/use: Date
Other(describe below):
General Information
Pumping Records:
Source of information:
Was system pumped as part of the inspection? ❑ Yes ® No
If yes, volume pumped:
gallons
How was quantity pumped determined?
Reason for pumping:
Type of System:
® Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
❑ Shared system (yes or no)(if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology. Attach a copy of the current operation and
.maintenance contract(to be obtained from system owner)and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other(describe):
t5ins•1 MCI Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 17
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
^M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Approximate age of all components, date installed (if known)and source of information:
1997
Were sewage odors detected when arriving at the site? ❑ Yes ® No
` Building Sewer(locate on site plan):
I 18..
Depth below grade: feet
Material of construction:
❑ cast iron ® 40 PVC ❑ other(explain):
Distance from private water supply well or suction line 0: feet
Comments (on condition of joints, venting, evidence of leakage, etc.):
Jointa appear tight.No evidence of Ieakage.System vented through the house vents.
Septic Tank(locate on site plan):
1'
Depth below grade: feet
Material of construction:
® concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain)
If tank is metal, list age:
years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No
Dimensions: 1500
Sludge depth: 2„
t5ins-1.110 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 9 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
°M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Septic Tank (cont.)
Distance from top of sludge to bottom of outlet tee or baffle
30"
Scum thickness
1"
Distance from top of scum to top of outlet tee or baffle
6"
Distance from bottom of scum to bottom of outlet tee or baffle
13"
How were dimensions determined? Measured
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Pump tank every two years.lnlet qand outlet tees are in place.No evidence of Ieakage.Tank appears
structurally sound.
Grease Trap (locate on site plan):
Depth below grade: feet
Material of construction:
❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping: Date
t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 10 of 17
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
^M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Capacity: gallons
Design Flow:
gallons per day
Alarm present: ❑ Yes ❑ No
Alarm level: Alarm in working order: ❑ Yes ❑ No
Date of last pumping: Date
Comments (condition of alarm and float switches, etc.):
*Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No
t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 17
r
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Distribution Box(if present must be opened) (locate on site plan):
Depth of liquid level above outlet invert No
Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
Box is Ievel.Box has one outlet Iateral.No evidence of solids carryover.No evidence of leakage.
Pump Chamber(locate on site plan):
Pumps in working order: ❑ Yes ❑ No
Alarms in working order: ❑ Yes ❑ No
Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.):
Soil Absorption System (SAS) (locate on site plan, excavation not required):
If SAS not located, explain why:
t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
°M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name-
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Type:
❑ leaching pits number:
® leaching chambers number: 5 Infiltrators
❑ leaching galleries number:
❑ leaching trenches number, length:
❑ leaching fields number, dimensions:
❑ overflow cesspool number:
❑ innovative/alternative system
Type/name of technology:
Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
Sandy.soil.No signs of hydraulic failure.Infiltrators were dry at time of inspection.
Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number and configuration
Depth—top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
Indication of groundwater inflow ❑ Yes ❑ No
t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 17
f
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
^M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
Privy(locate on site plan):
Materials of construction:
Dimensions
Depth of solids
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
t5ins•11/i0 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 17
.Map Page 1 of 2
Town of Barnstable Geographic Information System
Parcel Viewer Custom Map Abutters
Map Size OEM Zoom Out J 'In
y
a
4�
6.
J
� _ y
f.
;. _ .. M
i-
D 20 Feet
Set Scale 1" = 20 I Aerial Photos I MAP DISCLAIMER
f nn,irinhf,)onF_'Jf11O Tn...n of P—Oohlo hAA All rinhtc roc—,
t
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
^M 255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Site Exam:
® Check Slope
® Surface water
❑ Check cellar
❑ Shallow wells
Estimated depth to high ground water: Bottom of leaching 38'feet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed: Date
❑ Observed site (abutting property/observation hole within 150 feet of SAS)
® Checked with local Board of Health -explain:
As-Built
❑ Checked with local excavators, installers- (attach documentation)
❑ Accessed USGS database-explain:
You must describe how you established the high ground water elevation:
USED:USGS Observation Well Data.USED:Technical Bulletin 92-0001 plate#2 annual ranges of
groundwater elevations.
Before filing this Inspection Report, please see Report Completeness Checklist on.next page.
t5ins•11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
255 Shootflying Hill Rd.
Property Address
Kelly Dumas
Owner Owner's Name
information is required for Centerville Ma. 02632 12/23/2010
every page. City/Town State Zip Code Date of Inspection
E. Report Completeness Checklist
® Inspection Summary: A, B, C, D, or E checked
® Inspection Summary D (System Failure Criteria Applicable to All Systems)completed
® System Information—Estimated depth to high groundwater
® Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file
t5ins-11/10 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 17