Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0161 RIDGEWOOD AVENUE - Amnesty & MULTI-FAMILY
� l �:�d e °,� ;� I� �� P.� �� �`i kla� ` 4 C� Na'� P<-P D Oct^SL — f i i i 1 i i - _ l �,� v a t� l �:�d �C � . °,� p� �� ��; Cape Save Inc. 7-1) Huntington Avenue South Yarmouth, MA 02664 Tel: 508-398-0398 Fax: 508-398-0399 3/2/20 BUILDING DEPT. Brian Florence CBO MAY 2 ® .'''e Town of Barnstable Building Division 200 Main St. TOWN Hyannis, MA 02601 RE: Insulation Permit 20 99 Dear Mr. Florence: This affidavit is to certify that all work completed fory�161 Ridgewood Ave,Hyannisfhas been inspected by a third party Certified Building Performance Institute (BPI) Inspector. All work performed meets or exceeds Federal and State Requirements. Sincerely, William McCluskey ``7`"� s '�° � ��� �d'-c C� cam. -�-� ���:.,,,, Ct�-, -�:-�--- Town of Barnstable Building I Post This Card SOsThat itAs Visible From the Street Approved;Plans w ust be Retained oriJob�an&this Cartl Must be Kept a rwatv�rn�t e - Posted Until Final Inspect on`Has-Been Made Permit y l- g p p nt�l a Final Inspection has been made a p Y „ � quired,such Buldm shall Not_be Occu red u Wliere.a Certificate of Occu Kanc is Re ., ..._.��.,��: .,_�, .�.�...��. Permit No. B-20-99 Applicant Name: William McCluskey Approvals Date Issued: 01/13/2020 Current Use: Structure Permit Type: Building-Insulation-Residential Expiration Date: 07/13/2020 Foundation: Location: 161 RIDGEWOOD AVENUE, HYANNIS Map/Lot: 328-104 Zoning District: SF Sheathing: Owner on Record: MOREIRA, REGINA E Contractor NaQ'i William J McCluskley Framing: 1 Address: 161 RIDGEWOOD AVENUE Contractor License: 02776 2 HYANNIS, MA 02601 Est Projoct Cost: $3,600.00 Chimney : Description: Add R-38 fiberglass, R-45 cellulose,and R-10 rigid insulation to the Permit Fee: $85.00 Insulation: attic.Air seal the attic plane with expanding foam. General weatherization. ,Fee Paid: $85.00 Date: . 1/13/2020 Final: Project Review Req: Plumbing/Gas Rough Plumbing: \Building Official Final Plumbing: This permit shall be deemed abandoned and invalid unless the work authorized by this permit is commenced within six months after=issuance. All work authorized by this permit shall conform to the approved application and the'approved construction documents for which this permit has been granted. Rough Gas: All construction,alterations and changes of use of any building and structures shall'be in compliance with the local zoning by-laws antl codes. This permit shall be displayed in a location clearly visible from access street or,road and shall be maintained open for public'inspectioi for the entire duration of the Final Gas: work until the completion of the same. 4 ' Electrical The Certificate of Occupancy will not be issued until all applicable signatures by the Building and Fire officials are provided on this,permit. Minimum of Five Call Inspections Required for All Construction Work: Service: 1.Foundation or Footings Rough: 2.Sheathing Inspection 3.All Fireplaces must be inspected at the throat level before firest flue lining is installed Final: 4.Wiring&Plumbing Inspections to be completed prior to Frame Inspection 5.Prior to Covering Structural Members(Frame Inspection) Low Voltage Rough: 6.Insulation 7.Final Inspection before Occupancy Low Voltage Final: Where applicable,separate permits are required for Electrical,Plumbing,and Mechanical Installations, Health Work shall not proceed until the Inspector has approved the various stages of construction. Final: "Persons contracting with unregistered contractors do not have access to the guaranty fund" (as set forth in MGL c.142A). Fire Department Building plans are to be available on site Final: ca All Permit Cards are the property of the APPLICANT-ISSUED RECIPIENT W Lov�� Town of Barnstable g Building a i 1PostTh�s}Card�SoThat it isis�ble From-the Street<A rovedPlans Mst;be Retained onJob and�this Card M,usL.be Kept,t r �ARiQ'8'I'Aill.R b" Posted Until Final Inspection Has Been Made f a 4 - .. ., ��R.� � : �y� �� Permit Wh°ere a Certificate of Occu anc, pis Re, ulre�d,such„Buildm `shall Not;,be Occupied,untiJza Finat,lnspec�t�on h s been made,,- . Permit No. B-18-2681 Applicant Name: Brien Langill Vivint Solar Developer LLC Approvals Date Issued: 08/29/2018 Current Use: Structure Permit Type: Building-Solar Panel-Residential Expiration Date: 02/28/2019 Foundation: Location: 161 RIDGEWOOD AVENUE, HYANNIS Map/Lot: 328-104 Zoning District: SF Sheathing: Owner on Record: DEOLIVEIRA, LEANDRO E&MOREIRA, a Contractor Dame BRIEN LANGILL Framing: 1 n Address: 161 RIDGEWOOD AVENUE = Contractor Licen e CS-:106675 2 HYANNIS,MA 02601 4 Projct Cost: $ 19,360.00 Chimney: ki Installation of roof mounted photovoltaic solar s stems30 panels Pep rnitFee: 148.74 Description: ,� , p y 0 u $ Insulation: 8.85kW xf Fee Paitl $ 148.74 Project Review Req: z Date 8/29/2018 Final: " Plumbing/Gas Rough Plumbing: ,- Building Official Final Plumbing: - 14 1 1 Rough Gas: This permit shall be deemed abandoned and invalid unless the work authorized by this permit is commenced within six iphfhs after issuance. : All work authorized by this permit shall conform to the approved applitsti6ri-arid,the,approved construction documents¢orwhiel`this permit has been granted. Final Gas: All construction,alterations and changes of use of any building and structures shalle in compliance with the local zoning by laws-,and codes. This permit shall be displayed in a location clearly visible from access street or roaAnd shall be maintained open for publi inspection for the entire duration of the Electrical work until the completion of the same. ' 5 Service: The Certificate of Occupancy will not be issued until all applicable signatures bythe�Bwl�dmg and Fire Officials areprouidedo'n this permit. Minimum of Five Call Inspections Required for All Construction Work: Rough: 1.Foundation or Footing 2.Sheathing Inspection Final: 3.All Fireplaces must be inspected at the throat level before firest flue lining is installed 4.Wiring&Plumbing Inspections to be completed prior to Frame Inspection Low Voltage Rough: 5.Prior to Covering Structural Members(Frame Inspection) 6.Insulation Low Voltage Final: 7.Final Inspection before Occupancy Health Where applicable,separate permits are required for Electrical,Plumbing,and Mechanical Installations. Final: Work shall not proceed until the Inspector has approved the various stages of construction. 7"Pe�rs�dontracting with unregistered contractors do not have access to the guaranty fund" (as set forth in MGL c.142A). Fire Department Final: Building plans are to be available on site All Permit Cards are the property of the APPLICANT-ISSUED RECIPIENT TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Q—N A 14 Map Parcel l Application # Health Division Date Issued Conservation Division Application Fee Planning Dept. Permit Fee Date Definitive Plan Approved by Planning Board Historic - OKH _ Preservation / Hyannis Project Street Address rVI,A W601 t Village Owner L& Aro i vQ c Address I (, �(•��w� � . Telephone (�_ r ) 02 ka 7 90 Permit Request 1 S = 1► 2 DNS 4 !.r" -3? -}�-w� 4-3 Square feet: 1 st floor: existing proposed 2nd floor: existing proposed Total new Zoning District Flood Plain Groundwater Overlay Project Valuationao d L. 7?Construction Type Lot Size Grandfathered: ❑Yes ❑ No If yes, attach supporting documentation. Dwelling Type: Single Family � Two Family ❑ Multi-Family (# units) Age of Existing Structure Historic House: ❑Yes ❑ No On Old King's Highway: ❑Yes ❑ No Basement Type: ❑ Full ❑ Crawl ❑ Walkout ❑ Other Basement Finished Area (sq.ft.) Basement Unfinished Area (sq.ft) Number of Baths: Full: existing new Half: existing new Number of Bedrooms: existing _new Total Room Count (not including baths): existing new First Floor Room Count Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑ Other Central Air: ❑Yes ❑ No Fireplaces: Existing New Existing wood/coal stove: ❑Yes ❑ No Detached garage: ❑ existing ❑ new size_Pool: ❑ existing ❑ new size _ Barn: ❑ existing ❑ new size_ Attached garage: ❑ existing ❑ new size _Shed: ❑ existing ❑ new size _ Other: Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑Yes ❑ No If yes, site plan review# A Current Use Proposed Use f; ; rn - -" - APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Name �� �i k �N Sul C�,k� Telephone Number rb G Y 1 Address c� 13 -D Y a J— License # 0-4 7 7 S t>t Flees wy-\ 6 -)-'7 1 Home Improvement Contractor# O y t Email SAC'-•f e, ,��t-40 ✓v 6 ( Co.-.Worker's Compensation # 0 Y S O 00 ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BETAKEN TO i�nG ��fAar SIGNATURE DATE 2- 9 FOR OFFICIAL USE ONLY } APPLICATION# _ DATE ISSUED MAP/PARCEL NO. ' ADDRESS VILLAGE r OWNER { DATE OF INSPECTION: FOUNDATION FRAME I INSULATION FIREPLACE ELECTRICAL: ROUGH s s FINAL PLUMBING: ROUGH FINAL GAS: ROUGH FINAL FINAL BUILDING f DATE CLOSED OUT ASSOCIATION PLAN NO. M ReguUitory Seer.-A.c es Ricli rd V.Scali,Director Tom 'crry,l3irildinl„C:o=:ission r 200,M is-Street llyannis,NI:02.661 �i�rrvao�vn,ba�•nstalile:nia.c�s Office: 508-4S62-4038 Fix: 509-790-6230 Slrgio If Usimo--ABuilder j � r VC: in. r,Ue ,.' �...:; s thc:sulblb-t.prop il:y r -V \ ,. lacxriiy utlzn_ri` ) t 1i !1 ,,�_ tors c�ir rz, ehaJf in all mamas mla. i-v6 to work.,authoHmd;by this building.}e rnitt appHcation for- . . ) �i Al Ptaol Feaces and AS,CrrS aie the Pod are nrar.to`be Me d car it ed before fence is WOl d and all Ebal Sr,ratuse of, c r Prim.N"Lnle Pin hurmM at:� The Commonwealth of Massachusetts Department of Industrial Accidents 1 Congress Street,Suite 100 Boston,MA 02114-201 7 www mass govIdia lVorkers'Compensation Insurance Affidavit:Builders/Contractors/Elecfrieiaas/PIumbers. TO BE FILED WITH THE PERMITTING AUTHORUY. ApuficantInformation f Please Print LWbly Name(Business/OrganizaSon/lndividual):_ Address:_ City/State/Zip: S Z�1e c�vl� /9 Phone#: Are you an a ployer?Check the appropriate box: (�J.7 1 Type of project(required): 1=employer with--L�—ernpioyees(full andlor part time).' 7. Q New construction ?Q I am a sole proprieter or partnership and have no employees wonting for me in S. Q Remodeling any capacity.[No workers comp.insurance required.] 3. 1 am a homeowner doing all work t 9. ❑Demolition ❑ g myself[No workers comp.insurance required.] 4.Q I am a homeowner and will be hiring contractors to conduct all work on my property- 1 wall 10 Q Building addition ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees Cl I am a 12.Q Plumbing repairs or additions general contractor and I have hired the subcontractors listed on the attached sbeet 13.Q Roof repairs These ors have employees and bave worimrs'comp.insurance t 6.Q We are a corporation and its officers have exercised their right of exemtgtion per MQ,c. I4. I er 1514§1(41 and we have no employees.[No workers'comp.insurance required.] :Any applicasntthat checks box 91 must also fill out the section below showing their workers'compensation policy information. t Homeowners wfio submit this affidavit indicating they are doing all work and then hire outside connectors must submit a new affidavit indicating such. ZCo=..cturs that check this box must attacbzd an additional sheet showing the name of the sub-conmactors and soar whether or not those entities have employees If the sub-contractors have employees,flay must provide their workers'comp.policy number. I am an.employer that is provicww workers'compensation insurance for my employees Below is the policy and job site information. Insurance Company Name:_ 1po 2 T X)c Co Policy#or Self-ins.Lie.#:_ �,J C d� Y S�02. C) eJ Expiration Date- Job Site Address: �O t' r(� ZCW d City/Sta%Sipc ` ✓ -^�"6. r AA4-- Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiratioddate). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to S1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day a, mist the violator.A copy of this statement may be forwarded to the Office of investigations of the DIA for insurance coverage verification. I do hereby certify under th p and penalties of perjury that the information provided above is true and correct Signature: F2 Date: Phone#: S 9 �S — (0 41 c, Official use only. Do not w 'e in this area,to be completed by city or lawn offu!aL City or Town: Permit(License# Issuing Autho ' (circle one): 1.Board of Health--.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector b.Other Contact Person: Phone#: office of Ca Aff b and Bii Rego 14 Fide-Sdte 51T0 i 021•16 . low T rp1pi7.12M a4 Fw RoFrr titSULA t 1ORt NO. JdSEPH LL i P.Q. Box 105 SEEKE NK, MA 02771 +% Awl . �'•• � �Beat �� !�Lost� mmLNmkj- MAI a mown An co WAS W=1W141a&jAD4ra0106-& {,�iereCc7a�m�ae�ei� •�daa t+doest+iosa�x!'��ioa ry <�' . . . ��� �•a�#�omwm�r,il�xSanQ�x� a �" PilfA4t#Co�poeli�t 10lt��l�tt. �?Et FAtttQV!°�tii�A ;" Q ° iViassac4itrs.etts-Depattmetrt of Pubiic•.s'afef� _ .., .: •"diti Re Jiatic'ms=4 Sta cds. Boatri or 3�tt g g. . �u�5�i ui:wTi"�rluri ii5iii'�uioiisciiy' ��'•�.'(; License:'(S.SL-102771 .JOSM J.RE�I-f- PO Box 105 ' $eekDUkWA.-02711.. •ExptratiC;t4-:r. 06T05130 Carnmissioter. 17t;: q RETRINS-01 RBLACK1 A D- CERTIFICATE OF LIABILITY INSURANCE DATE(MIYYYY) 7/27/2D01 s THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#1780862 CONTACT HUB International New England PHONE (508)676-1871 a No: 508 578-2750 222 Milliken Boulevard A/C Ne"J: ( ) Fall River,MA 02722-9946 E-MAIL ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC it INSURERA:Star Insurance Company 118023 INSURED INSURERS: RetroFit Insulation,Inc. INSURER C: PO Box 105 INSURER D: Seekonk,MA 02771 INSURER E: INSURER F• COVERAGES CERTIFICATE NUMBER: REVISION NUMBER.- THIS 1S TO CERTIFY THAT THE POLICIES CF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PEFSTAINt THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPE OF INSURANCE INS wvD POLICYNUMBER ' MMIoFOLICY MM1DO YYH. LIMITS 'COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE S CLAIIdS•NADE ❑OCCUR X PREMISES Ea occurrence s MED EXP(Any one person) Is PERSONAL&ADV INJURY S I GEN'LAGGREGATE LIMIT APPLESPER. GENERAL AGGREGATE S POLICY a JECT PRI D LOC PRODUCTS-COMPIOP AGG 1 S OTHER: !S AUTOMOBILE 1JABILITY COMBINED SINGLE LIMIT S Ea accident ANYAUTO BODILY INJURY(Par person) $ ALLOWNED SCHEDULED AUTOS AUTOS 8001LY INJURY(Per act der>t? S HIREDAUTOS AUTOS NON-OWNED (PerraeadenOAMAGE S S UMBRELLALIAB OCCUR EACH OCCURRENCE S EXCESSLIAB HCLAIMS-MADE AGGREGATE S DED I I RETENTIONS Is WORKERS COMPENSATION TA O7ti AND EMPLOYER SLIABILITY STATUTE ER A ANYPROPRIETORIPAR UTIVE YIN C08452.01 0810212016 08102/2017 E.L.EACH ACCIDENT s 1,�Q0.000 OFFICERIMEMBER EXCLUDED? NIA 0WariditooinNH) E.L DISEASE-EAEMPLOY S 1,000,000 If yes.cescribe wder DESCRIPnONOFOPERAMONSbelov E.L DISEASE-POLCYUMrr I s 1,000,000 DESCRIPTION OF OPERATIONS 1 LOCATIONS I VEHICLES(ACORD 101,Additional Remarla Schedule,may be attached if more space Is rcqulrod) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCEI I M BEFORE National Grid THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 511 Washington Street Westborough,MA 01581 AUTHORIZED REPRESENTATIVE 01988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD SolarCityr May 6, 2016 Town of Barnstable ATTENTION: BUILDING DEPARTMENT 200 Main Street Hyannis, MA 02601 RE: 161 Ridgewood Avenue, Hyannis Permit No.: 201504174 Our Job No.: 1B-0261363 — s {,fir NOTICE OF CANCELLATION This letter is to certify our proposal to install Solar(PV)at the above-referenced property has been moved into a cancellation status. , SolarCity Corporation and Regina Moreira will not be moving for ward with the proposed installation at this time. r If you have any questions or concerns, please don't hesitate to contact me. Thank you for your attention to this matter. Sincerely, Cheryl Gruenstern Cheryl Gruenstern Permit Coordinator Direct Line: (508)640-5397 cgruenstem@solarcity.com 112 Great Western Road,South Dennis,MA 02660 T (888)SOL-CITY solarcity.com AL 05500.PR M-8937,AZ ROC 24377VROC 245450,CA CSLB 888104.CO EC8041.CT HIC 0632TJ8/ELC 0125305.DC 410514000080/ECC902585.DE 2 01112 0 3 8 6/Tt-6032,FL EC13006226.HI CT-29770.Il 15-0052.MA HIC 168572/ EL-1136MR,MD HIC 12E94B/11805,NC 30801-11,NH 0347C/12523M.NJ NJHIC#13VH06160600/34E801732700.NM EE98-379590,NV NV20127 35172/C2-0078648/B2-0079719.OH EL.47707,OR CB180498/C562.PA HICPA077343.PJ AC004714/Reg 38313,TXTECE27006.UT 8726950-6501.VA ELE2705153278,Vr EM-05829,WA SOLARC•919OVSOLARC•905P7.Albany 439.Greene A-486.Nassau H2409710000.Putnam PC6041,Roddand H-11864-40-00-00.Suffolk 52057-H.Westchester WC-26088-H13.N.Y.0#2001384-0CA SCENYC:N.V.C.Licensed Electrician.#12610.#004485.155 Wata St.6th Fl.,Unit 10.Brooklyn.NY 11201#2013966-0CA All loans proAded by 5olarCity Finance Company.I.I.C. CA Finance Lenders license 6054796.SolarCity Finance Company,LLC Is licensed by the Delaware State Bank Commissioner to engage In business In Delaware under license number 019422.MD Consumer Loan License 2241,NV Installment Loan Llcense ILM23/I1.71024,RI Licensed lender#20153103LL.TX Registered Creditor 1400050963-202404.Vr Lender License#6766 TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION l Map Parcel 169 Application # c�? Health Division Date Issued? Conservation Division Application Fee C� Planning Dept. Permit Fee 1 Date Definitive Plan Approvedby Planning Board Historic - OKH N(� _ Preservation/ Hyannis 4 Project Street Address Village Owne d ress I b t r 1 �g�h� �rt1,ra- c ati�� dr NU Telephone LI A as 1• ij q? a-v�r\ �,k+ V-X(,,0 Permit Request (` .\� �� mr., t-, b,�- e 15 -lK hVrt& U_,N �G��o e- � 5 C•1 a E t o t �' l rl T�r ►�c e3Zd U.)g r✓ c w( 5 yK W c�hc�S Square feet: 1 st floor: existing proposed — 2nd floor: existing proposed Total new Zoning District S1 Flood Plain Groundwater Overlay _ Project Valuation 51&,660 Construction Type Lot Size Grandfathered: ❑Yes 0.No If yes, attach supporting documentation. Dwelling Type: Single Family ,r�,' Two Family ❑ Multi-Family (# units) Age of Existing Structure Historic House: ❑Yes 'td-No On Old King's Highway: ❑Yes ZNo Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑ Other Basement Finished Area (sq.ft.) Basement Unfinished Area (sq.ft) Number of Baths: Full: existing new Half: existing new Number of Bedrooms: existing _new — Total Room Count (not including baths): existing — new / First Floor Room Count Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑ Other N f� Central Air: ❑Yes ❑ No Fireplaces: Existing 46IJew Existing wood/coal stove: ❑Y s ❑ o M ,41 Detached garage: ❑ existing ❑ new siz 11 ool: ❑ existing ❑ new size/' Barn: owexisting 0 pew--=siz Attached garage: ❑ existing ❑ new sizQ- hed: ❑ existing ❑ new size her: `� w d F`vyf jiff Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ =• Commercial ❑Yes 6 No If yes, site plan review# 77 _c=- Current Use ,%StG,e� �-� Proposed Use 46 4,11 I L ., APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Name &Y\ I G- / !57)14A Telephone Number (5-62 • Ls4 6 •5 3� Address rca� W�S (� License # CJ' ILo 15 Home Improvement Contractor# I (PS5 72 Email OQ r-U ri u\ `SDI . c6K Worker's Compensation # W A '�� ALL CO TRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL' p-E TAKEN TO Cc��,AS4 �tL� C�"� �D w•l�. CA l+1c [VI �U� SIGNATURE DATE )�-�n� 3b, &O is f FOR OFFICIAL USE ONLY APPLICATION# DATE ISSUED MAP/PARCEL NO. y ADDRESS VILLAGE ' OWNER DATE OF INSPECTION: FOUNDATION FRAME INSULATION FIREPLACE ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH FINAL GAS: ROUGH FINAL FINAL BUILDING l , DATE CLOSED OUT ASSOCIATION PLAN NO. DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 SolarCity I PPA Customer Name and Address Installation Location Date Issued Regina Moreira 161 Ridgewood Ave 6/23/2015 Leandro De Oliveira Barnstable,MA 02601 161 Ridgewood Ave Barnstable,MA 02601 Here are the key terms of your Power Purchase Agreement 14 0 20yrs ' System installation cost Electricty rate kWh Agreemen Tgyrm Initial here Initial here The SolarCity Promise � •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. ......................................................................... Initial here •We warrant all of our roofing work. os •We restore your roof at the end of the Agreement. •We warrant, insure,maintain and repair the System. ........................:......................................................................................................................................................................................... Initial here •We fix or pay for any damage we may cause to your property. •We provide 24/7 web-enabled monitoring at no additional cost. •The rate you pay us will never increase by more than 2.90%per year. •The pricing in this Agreement is valid for 30 days after 6/23/2015. •You are free to cancel any time prior to construction at no charge. Your SolarCity Power Purchase Agreement Details Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing Term: •At certain times,as specified in $0 •SolarCity will remove the System at no the Agreement,you may Est.amount due at installation cost to you. purchase the System. $0 •You can upgrade to a new System with •These options apply during the 20 the latest solar technology under a new year term of our Agreement and Est.amount due at building inspection contract. not beyond that term. $0 •You may purchase the System from Est.first year production SolarCity for its fair market value as 8,128 kWh specified in the Agreement. •You may renew this Agreement for up to ten(10)years in two(2)five(5)year increments. solarcity.com 888.765.2489 885528 Power Purchase Agreement,version 9.0.0,June 22,2015 SAPC/SEFACompliant Q ■� Contractors License MA HIC 168572/EL-1136MR Copyright 2008-2015 SolarCity Corporation,All Rights.Reserved DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 1. Introduction. March 1). Monthly Payments will change as your price per kWh changes over the Term of this PPA and as This Power Purchase Agreement(this"Power Purchase Agreement,""Agreement"or"PPA")is the agreement System production varies(e.g.,summer has higher production).You will have regular access to the between you and SolarCity Corporation(together with its successors and assigns,"SolarCity"or"we"),covering the System's production via your SolarCity online account. Payments due upon installation,if any,are due sale to you of the power produced by the solar panel immediately prior to commencement of installation. system(the"System")we will install at your home. SolarCity agrees to sell to you,and you agree to buy from You will make no Monthly Payments if you are fully SolarCity,all of the power produced by the System. The prepaying this PPA. In this case,you will pay only the System will be installed by SolarCity at the address you amounts listed in the key terms summary on page one of this PPA. listed above(the"Property"or your"Home"). This Power Purchase Agreement is eight(8)pages long and has up to (c) Estimated Production. If(i)the System is shut down for three(3) Exhibits depending on the state where you live. more than seven(7)full twenty-four(24)hour days SolarCity provides you with a Limited Warranty(the cumulatively during the Term because of your actions; "Limited Warranty"). The Limited Warranty is attached as or(ii)you take some action that significantly reduces Exhibit 2. If you have any questions regarding this Power the output of the System;(iii)you don't trim your Purchase Agreement, please ask your SolarCity sales bushes or trees to their appearance when you signed consultant. this PPA to avoid foliage growth from shading the 2. Term. System;or(iv)your System is not reporting production to SolarCity(e.g.you have disconnected the SolarCity agrees to sell you the power generated,by the PowerGuide system or the internet connection at'your System for 20 years(240 months), plus,if the Home goes down on the reporting day),then SolarCity Interconnection Date is not on the first day of a calendar will reasonably estimate the amount of power that month,the number of days left in that partial calendar would have been delivered to you during such System month. We refer to this period of time as the"Term." The or reporting outages or reduced production periods Term begins on the Interconnection Date. The ("Estimated Production")and shall consider Estimated "Interconnection Date"is the date that the System is Production as actual production for purposes of this turned on and generating power. SolarCity will notify you paragraph. In the first year of the Term, Estimated when your System is ready to be turned on. Production will be based on our production projections. 3. Intentionally Left Blank. After the first year of the Term,Estimated Production will be based on historical production for that month in 4. Power Purchase Agreement Payments:Amounts. the prior year. If we bill you for Estimated Production (a) Power Price. During the first year of the term,You are because your System is not reporting production to purchasing all of the power the System produces for SolarCity,and'we subsequently determine that we have $0.1250 per kWh. After the first year,the price per either overestimated or underestimated the actual kWh will increase by.2.90%per year.There are no production,then we will adjust the next bill downward installation costs. (to refund overbilling)or upward(to make up for lost billing). You will not be charged for Estimated (b)Payments. Production when the System is not producing electricity Your monthly payments will be the product of(A)the due to SolarCity's fault,or if it's due to grid failure or . price per kWh multiplied by(B)the actual kWh output power outages caused by someone other than you. for the calendar month("Monthly Payments"). Invoices S. Power Purchase Agreement Obligations. for Monthly Payments will be mailed or emailed no later than ten(10)days after the end of a calendar (a) System,Home and Property Maintenance month. If you are paying your invoice by automatic You agree to: debit from your checking or savings account(ACH)we will debit your bank account on or about the 15t day of (i) only have the System repaired pursuant to the the next month following invoice(e.g.January invoices Limited Warranty and reasonably cooperate are sent in early February and debited on or about when repairs are being made; Power Purchase Agreement version 9.0.0,June 22,2015 [No� 0 885528 DocuSign Envelope ID:66DF815C-DQBO-461B-8B1E-7DC27A4FFF28 (ii) keep trees,bushes and hedges trimmed so that will otherwise impact the System,its installation the System receives as much sunlight as it did or operation. when SolarCity installed it; (b) System Construction,Repair,Insurance and (iii) not modify your Home in a way that shades the SolarCity's obligations: System; SolarCity agrees to: (iv) be responsible for any conditions at your Home that affect the installation(e.g.,blocking access U) schedule the installation of the System at a to the roof,or removing a tree that is in the way, mutually convenient date and time; prior work you have done on your home that was (ii) construct the System according to written plans not permitted); you review; (v) not remove any markings or identification tags (iii) provide you with a web-enabled meter to on the System; accurately measure the amount of power the NO permit SolarCity, after we give you reasonable System delivers to you; notice,to inspect the System for proper (iv) provide you with a home energy evaluation; operation as we reasonably determine (v) notify you if the System design has to be necessary; materially changed so that you can review any (vii) use the System primarily for personal,family or such changes; household purposes,but not to heat a swimming NO clean up after ourselves during the construction pool; of the System; (viii) not do anything, permit or allow to exist any (vii) insure the System against all damage or loss condition or circumstance that would cause the unless(A)that damage or loss is caused by your System not to operate as intended at the gross negligence;or(B)that damage or loss is Property; caused by ball strikes;or(C)you intentionally (ix) notify SolarCity if you think the System is damage the System; damaged or appears unsafe;if the System is (viii) repair the System pursuant to the Limited stolen;and prior to changing your power Warranty and reasonably cooperate with you supplier; when scheduling repairs; (x) have anyone who has an ownership interest in (ix) create a priority stream of operation and your Home sign this Power Purchase Agreement; maintenance payments to provide enough cash (xi) return any documents we send you for signature flow in our financing transactions to pay for the (like incentive claim forms)within seven (7)days Limited Warranty obligations and the repair and of receiving them;and maintenance of the System in accordance with (xii) maintain and make available,at your cost,a this PPA even if SolarCity ceases to operate;and functioning indoor internet connection with a (x) not put a lien on your Home or Property. router,one DHCP enabled Ethernet port with internet access and standard AC power outlet (c) Home Renovations or Repairs close enough and free of interference to enable an If you want to make any repairs or improvements to internet-connected gateway provided by SolarCity the Property that could interfere with the System to communicate wirelessly with the system's . inverter(typically this is 80 feet,but may depend (such as repairing the roof where the System is located),you may only remove and replace the on site conditions). See section 2(c)(ii)of the System pursuant to the Limited Warranty. Limited Warranty for details;and (xiii) if your home is governed by a home owner's (d) Automatic Payment,Late Charges,Fees association or similar community organization, In addition to the other amounts you agree to pay in obtain all approvals and authorizations for the this Power Purchase Agreement,you agree to pay the System required by that organization and advise following: us of any requirements of that organization that Power Purchase Agreement version 9.0.0,June 22,2015 [oil 19 9 88552811 _T N. 1 ` i DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 (i) Automatic Payment Discount: All prices include a the utility's electric distribution system;or(D) $7.50 monthly discount for allowing us to taking any other action reasonably necessary in automatically debit your checking or savings connection with installing,constructing, account for payments. You will not receive a operating,owning,repairing,removing and $7.50 monthly discount if you do not allow the replacing the System.This access right shall automatic debit; continue for up to ninety(90)days after this (ii) Returned Check Fee:$25(or such lower amount Power Purchase Agreement expires to provide as required by law)for any check or withdrawal SolarCity with time to remove the System at the right that is returned or refused by your bank;and end of the Power Purchase Agreement. (iii) Late Payments:accrue interest at the lesser of SolarCity shall provide you with reasonable twelve percent(12%)annually or the maximum notice of its need to access the Property allowable by applicable law. whenever commercially reasonable. (e) Taxes (ii) During the time that SolarCity has access rights you shall ensure that its access rights are Your SolarCity electricity rate of$0.1250 per kWh is preserved and shall not interfere with or permit composed of an electricity rate of$0.1250 plus any third party to interfere with such rights or current taxes'of$0.0000.You agree to pay any access. You agree that the System is not a changes in the applicable taxes related to this PPA. fixture,but SolarCity has the right to file any Thus,if tax rates change,your SolarCity electricity UCC-1 financing statement or fixture filing that rate will change to reflect this rate change: If this confirms its interest in the System. PPA contains a purchase option at the end of the (h) Indemnity Term,you agree to pay any applicable tax on the purchase price for the System.You also agree to pay To the fullest extent permitted by law,you shall as invoiced any applicable personal property taxes indemnify,defend,protect,save and hold harmless on the System that your local jurisdiction may levy. SolarCity,its employees,officers,directors,agents, (f) No Alterations successors and assigns from any and all third party claims,actions,costs,expenses(including You agree that you will not make any modifications, reasonable attorneys'fees and expenses),damages, improvements,revisions or additions to the System liabilities, penalties,losses,obligations,injuries, or take any other action that could void the Limited demands and liens of any kind or nature arising out Warranty on the System without SolarCity's prior of,connected with,relating to or resulting from your written consent. If you make any modifications, negligence or willful misconduct;provided,that improvements,revisions or additions to the System, nothing herein shall require you to indemnify they will become part of the System and shall be SolarCity for its own negligence or willful SolarCity's property. misconduct.The provisions of this paragraph shall (g) Access to the System survive termination or expiration of this Power Purchase Agreement. (i) You grant to SolarCity and its employees,agents (i) Payments and contractors the right to reasonably access all of the Property as necessary for the purposes SUBJECT TO SECTION 4(b)ABOVE,YOU AGREE THAT of(A)installing,constructing,operating, THE OBLIGATION TO PAY ALL PAYMENTS AND ALL owning,repairing,removing and replacing the OTHER AMOUNTS DUE UNDER THIS PPA SHALL BE, System or making any additions to the System ABSOLUTE AND UNCONDITIONAL UNDER ALL or installing complementary technologies on or CIRCUMSTANCES AND SHALL NOT BE SUBJECT TO about the location of the System;(B)enforcing ANY ABATEMENT, DEFENSE,COUNTERCLAIM, SolarCity's rights as to this Power Purchase SETOFF,RECOUPMENT OR REDUCTION FOR ANY Agreement and the System;(C)installing,using REASON WHATSOEVER,IT BEING THE EXPRESS and maintaining electric lines and inverters and INTENT OF THE PARTIES THAT ALL AMOUNTS meters, necessary to interconnect the System to PAYABLE BY YOU HEREUNDER SHALL BE,AND your electric system at the Property and/or to CONTINUE TO BE,PAYABLE IN ALL EVENTS Power Purchase Agreement version 9.0.0,June 22,2015 R 885528 -U CA-MEW NIS i DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 INCLUDING BY YOUR HEIRS AND ESTATE AND, necessary roof repairs to enable us to safely EXCEPT AS SET FORTH BELOW IN SECTIONS 6,23 install the System). AND 24,YOU HEREBY WAIVE ALL RIGHTS YOU MAY (viii) if your home is governed by a home owner's HAVE TO REJECT OR CANCEL THIS PPA,TO REVOKE association or similar community organization, ACCEPTANCE OF THE SYSTEM,OR TO GRANT A your receipt of all approvals and authorizations SECURITY INTEREST IN THE SYSTEM. for the System required by that organization and (j) Credit Check advising us of any requirements of that organization that will otherwise impact the You authorize SolarCity,or its designee,to obtain System,its installation or operation. your credit report now and in the future,check your credit and employment history,answer questions SolarCity may terminate this Power Purchase others may ask regarding your credit and share your Agreement without liability if,in its reasonable credit information with SolarCity's financing judgment,any of the above listed conditions(i) partners.You certify that all information you provide through(vii)will not be satisfied for reasons beyond to us in connection with checking your credit will be its reasonable control. Once SolarCity starts true and understand that this information must be installation,however,it may not terminate this updated upon request if your financial condition Power Purchase Agreement for your failure to changes. satisfy conditions(i)through (vii)above. 6. Conditions Prior to Installation of the System;Change (b) Amendments. Orders. The System's initial estimated production is set forth (a) SolarCity's obligation to install the System and sell in this PPA.After System design,the estimated you the power it produces is conditioned on the production is likely to change and we will share following items having been completed to its those changes with you prior to installation. If the reasonable satisfaction: estimated production increases or decreases by more than twenty percent(20%),we will document (i) completion of(A)the engineering site audit(a that change in an amendment.. thorough physical inspection of the Property, including,if applicable,geotechnical work),(B) You authorize SolarCity to make corrections to the utility paperwork to conform to this PPA or any the final System design, and(C)real estate due diligence to confirm the suitability of the amendments to this PPA we both sign. Property for the construction,installation and 7. Warranty. operation of the System; YOU UNDERSTAND THAT THE SYSTEM IS WARRANTED (ii) approval of this Power Purchase Agreement by SOLELY UNDER THE LIMITED WARRANTY ATTACHED AS one of SolarCity's financing parties; EXHIBIT 2,AND THAT THERE ARE NO OTHER (iii) your meeting the applicable credit score; REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, (iv) confirmation of rebate,tax credit and AS TO THE MERCHANTABILITY, FITNESS FOR ANY PURPOSE, renewable energy credit payment availability in CONDITION, DESIGN,CAPACITY,SUITABILITY OR the amount used to calculate the Monthly PERFORMANCE OF THE SYSTEM OR ITS INSTALLATION. Payments set forth in this Power Purchase 8. Transfer. Agreement; SolarCity will assign this PPA to one of its financing (v) confirmation that SolarCity will obtain all partners. You agree that SolarCity may assign,sell or applicable benefits referred to in Section 9; transfer the System and this Power Purchase Agreement, NO receipt of all necessary zoning,land use and or any part of this Power Purchase Agreement or the building permits;and exhibits,without your consent. This assignment does not NO completion of any renovations,improvements change SolarCity's obligation to maintain and repair your or changes reasonably required at your Home System as set forth in the Warranty. or on the Property(e.g., removal of a tree or Power Purchase Agreement version 9.0.0,June 22,2015 EWE 885528 *IQ g DocuSign Envelope ID:66DF815C-D980-461B-8B1E-7DC27A4FFF28 9. . Ownership of the System;Tax Credits and Rebates. charge of no less than$10.00(ten dollars)per month until You agree that the System is SolarCity's personal property adequate Internet monitoring is implemented or restored. under the Uniform Commercial Code. You understand and 10. Purchasing the System Prior to the End of the Term. agree that this PPA is not a contract to sell or lease the In addition to purchasing the System at the end of the System to you. SolarCity owns the System for all purposes, Term,you have the option to purchase the System prior to including any data generated from the System. You shall at the end of the Term as detailed below. To exercise this all times keep the System free and clear of all liens,claims, option you must be in good standing under this Power levies and legal processes not created by SolarCity, and Purchase Agreement and you need to give us at least one shall at your expense protect and defend SolarCity against (1)month's,but not more than three(3)months' prior the same. written notice. You can purchase this System: YOU UNDERSTAND AND AGREE THAT ANY AND ALL TAX (i) on the five(5)year anniversary of the CREDITS,, INCENTIVES, RENEWABLE ENERGY CREDITS, beginning of the Term and every annual GREEN TAGS,CARBON OFFSET CREDITS, UTILITY REBATES anniversary a OR ANY OTHER NON-POWER ATTRIBUTES OF THE SYSTEM after the five(5)year anniversary; and ARE THE PROPERTY OF AND FOR THE BENEFIT OF SOLARCITY, USABLE AT ITS SOLE DISCRETION.SOLARCITY (ll) at any time after the five(5)year anniversary SHALL HAVE THE EXCLUSIVE RIGHT TO ENJOY AND USE ALL of the beginning of the Term,when you sell SUCH BENEFITS,WHETHER SUCH BENEFITS EXIST NOW OR your Home;and IN THE FUTURE. YOU AGREE TO REFRAIN FROM ENTERING (iii) if SolarCity ever ceases its operations. INTO ANY AGREEMENT WITH YOUR UTILITY THAT WOULD In each of(i),(ii)and(iii)above,the price you will pay for ENTITLE YOUR UTILITY TO CLAIM ANY SUCH BENEFITS. the System will be the System's fair market value("FMV"). YOU AGREE TO REASONABLY COOPERATE WITH SOLARCITY A third party independent appraiser will be retained to SO THAT IT MAY CLAIM ANY TAX CREDITS, RENEWABLE compute the System's FMV. SolarCity's maintenance and ENERGY CREDITS, REBATES,CARBON OFFSET CREDITS OR repair obligations under the Limited Warranty(Exhibit 2) ANY OTHER BENEFITS FROM THE SYSTEM.THIS MAY will continue when you purchase the System until what INCLUDE TO THE EXTENT ALLOWABLE BY LAW, ENTERING would have been the end of the original Term. INTO NET METERING AGREEMENTS, INTERCONNECTION AGREEMENTS,AND FILING RENEWABLE ENERGY/CARBON 11. Renewal. OFFSET CREDIT REGISTRATIONS AND/OR APPLICATIONS If you are in compliance with your PPA,you have the option FOR REBATES FROM THE FEDERAL,STATE OR LOCAL to renew your PPA for up to ten(10)years in two(2)five(5) GOVERNMENT OR A LOCAL UTILITY AND GIVING THESE TAX year renewal periods. We will send you renewal forms three CREDITS, RENEWABLE ENERGY/CARBON CREDITS, REBATES (3)months prior to the expiration of the Term,which forms OR OTHER BENEFITS TO SOLARCITY. shall set forth the new'Monthly Payments due under the renewal PPA,based on our assessment of the then current You understand that solar renewable energy credits fair market value of the System. If you want to renew, (SRECs)and certain incentives and associated data cannot be generated or earned without Internet.As such,you complete the renewal forms and return them to us at least agree to maintain and make available,at your cost,a one(1)month prior to the end of the PPA. In the event that functioning indoor Internet connection with.the- you do not agree to the new Monthly Payments this PPA understanding that Wi-Fi hotspotting,tethering and shall expire by its terms on the termination date. If you don't send us anything in writing after we send you the intermittent Internet connection will not satisfy this obligation.You also agree to cooperate with SolarCity as renewal forms,then this PPA shall renew for an additional necessary to one(1)year term at ten percent(10%)less than the then- generate SRECs or earn incentives and troubleshoot provide any other information required to . current average rate charged by your local utility and shall monitoring issues.Your failure to cooperate with SolarCity continue to renew for one(1)year terms at the same rate as with respect to Internet requirements will result in your your first renewal until(i)you give us notice at least thirty obligation to compensate SolarCity for all lost SREC or (30)days prior to a renewal term that you do not wish to incentive revenue and related costs,subject to a monthly renew;or(ii)we send you a notice terminating the PPA. 12. Selling Your Home. Power Purchase Agreement version 9.0.0,June 22,2015 [oil 91 885528 . -WOUBLItkir �Y DocuSign Envelope ID:66DF815C-D9130-46113-8131E-7DC27A4FFF28 (a) If you sell your Home you can: (c) If you sell your Home and can't comply with any of the (i)Transfer this Power Purchase Agreement and the options in subsection(a)above,you will be in default Monthly Payments under this Power Purchase Agreement. Section 12(a) includes a Home sale by your estate or heirs. The person buying your Home(the Home Buyer") can sign a transfer agreement assuming all of your (d) Free Assumability.This agreement is free of any restrictions that would prevent the homeowner from rights and obligations under this Agreement by qualifying in one of three ways: freely transferring their home("Property").SolarCity 1) The Home Buyer has a FICO score of 650 or will not prohibit the sale,conveyance or refinancing of the Property.SolarCity may choose to file in the real greater; 2) The Home Buyer is paying cash for your estate records a UCC-1 financing statement("Fixture Home;or Filing")that preserves their rights in the System.The 3) If the Home Buyer does not qualify under(1) Fixture Filing is intended only to give notice of its rights or(2),the Home Buyer qualifies for a relating to the System and is not a lien or mortgage to purchase your Home and either encumbrance against the Property.SolarCity shall you or the Home Buyer pays us'a$250 credit explain the Fixture Filing to any subsequent purchasers exception fee. of the Property and any related lenders as requested. SolarCity shall also accommodate reasonable requests (ii)Move the System to Your New Home from lenders or title companies to facilitate a' Where permitted by the utility(s),the System can be purchase,financing or refinancing of the Property. moved to your new home pursuant to Section 4 of the Limited Warranty.You will need to provide the (e) EXCEPT AS SET FORTH IN THIS SECTION,YOU WILL NOT same rights to SolarCity as provided for in this PPA ASSIGN,SELL, PLEDGE OR IN ANY OTHER WAY and provide any third party consents or releases TRANSFER YOUR INTEREST IN THE SYSTEM OR THIS required by SolarCity in connection with the PPA WITHOUT OUR PRIOR WRITTEN CONSENT,WHICH substitute premises. SHALL NOT BE UNREASONABLY WITHHELD. (iii)Prepay this Power Purchase Agreement and Transfer only the Use of the System 13. Loss or Damage. At any time during the Term,you can prepay this Power Purchase Agreement in full by paying (a) Unless you are grossly negligent,you intentionally SolarCity the expected remaining payments damage the System,or damage or loss to the System is (estimated future production during the rest of the caused by ball strikes,SolarCity will bear all of the risk Term multiplied by the average kWh rate during the. of loss,damage,theft,destruction or similar occurrence rest of the Term)at a five percent(5%)discount to any or all of the System. Except as expressly rate.The person buying your Home will only need to provided in this PPA,no loss,damage,theft or sign a transfer agreement to assume your rights and destruction will excuse you from your obligations under non-Monthly Payment obligations under this PPA. this PPA, including Monthly Payments. The System stays at your Home,the person buying (b)If there is loss,damage,theft,destruction or a similar your Home does not make any Monthly Payments occurrence affecting the System,and you are not in and has only to comply with the non-Monthly default of this PPA,you shall continue to timely make all Payment portions of this PPA. Monthly Payments and pay all other amounts due (iv)Purchase the System(see Section 10) under the PPA and,cooperate with SolarCity,at (b) You agree to give SolarCity at least fifteen (15)days SolarCity's sole cost'and expense,to have the System but not more than three(3)months prior written repaired pursuant to the Limited Warranty. notice if you want someone to assume your PPA 14. Limitation of Liability. obligations. In connection with this assumption,you, your approved buyer and SolarCity shall execute a (a)No Consequential Damages written transfer of this PPA. SOLARCITY'S LIABILITY TO YOU UNDER THIS POWER PURCHASE AGREEMENT SHALL BE LIMITED TO DIRECT, ACTUAL DAMAGES ONLY. YOU AGREE THAT IN NO Power Purchase Agreement version 9.0.0,June 22,2015 [Nil n a 885528 DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 EVENT SHALL EITHER PARTY BE.LIABLE TO THE OTHER (c) require you,at your expense,to return the System or FOR CONSEQUENTIAL, INCIDENTAL, PUNITIVE, make it available to us in a reasonable manner; EXEMPLARY,SPECIAL OR INDIRECT DAMAGES. (d)proceed, by appropriate court action,to enforce (b)Actual Damages performance of this PPA and to recover damages for EXCEPT FOR CLAIMS UNDER SECTION 5(H), NEITHER your breach; PARTY'S LIABILITY TO THE OTHER WILL EXCEED AN (e)disconnect,turn off or take back the System by legal AMOUNT EQUAL TO THE MAXIMUM AMOUNT THAT process or self-help, but we may not disturb the peace COULD BE PAYABLE BY YOU UNDER SECTION 16(H). or violate the law; DAMAGES TO YOUR HOME, BELONGINGS OR PROPERTY (f) report such non-operational status of the System to RESULTING FROM THE INSTALLATION OR OPERATION your utility,informing them that you are no longer net OF THE SYSTEM ARE COVERED IN SECTION 6(C)OF THE metering; LIMITED WARRANTY. 15. Default. (g) charge you a reasonable reconnection fee for reconnecting the System to your utility or turning your You will be in default under this Power Purchase System back on after we disconnect or turn off the Agreement if any one of the following occurs: System due to your default; (a) you fail to make any payment when it is due and such (h)recover from you(i)a payment equal to the purchase failure continues for a period of ten(10)days; price as set forth in this agreement plus(ii)all taxes, (b) you fail to perform any material obligation that you late charges,penalties,interest and all or any other have undertaken in this PPA(which includes doing sums then accrued or due and owing;or something you have agreed not to do, like alter the (i) use any other remedy available to us in this PPA or by System)and such failure continues for a period of law. fourteen(14)days after written notice; We may submit to credit reporting agencies(credit (c) you or your guarantor have provided any false or bureaus)negative credit reports that would be reflected on misleading financial or other information to obtain this your credit record if you do not pay any amounts due Power Purchase Agreement; under this PPA as required. (d) you assign,transfer,encumber, sublet or sell this PPA or You agree to repay us for any reasonable amounts we pay . any part of the System without SolarCity's prior written to correct or cover your default.You also agree to consent;or reimburse us for any costs and expenses we incur relating (e) you or any guarantor makes an assignment for the to the System's return resulting from early termination. By benefit of creditors,admits in writing its insolvency, choosing any one or more of these remedies,SolarCity files or there is filed against you or it a voluntary does not give up its right to use another remedy. By petition in bankruptcy,is adjudicated bankrupt or deciding not to use any remedy should this Power insolvent or undertakes or experiences any substantially Purchase Agreement be in default,SolarCity does not give similar activity. up our right to use that remedy in case of a subsequent default. 16. Remedies in Case of Default. 17. System Removal;Return. If this Power Purchase Agreement is in default,we may take any one or more of the following actions. If the law At the end of the Term or the termination of this PPA, if requires us to do so,we will give you notice and wait any You have not renewed this PPA or exercised your purchase period of time required before taking any of these actions. option(if any)and you have not defaulted,then within We may: ninety(90)days you agree to call SolarCity at the telephone number listed in Section 7 of Exhibit 2 to (a)terminate this PPA; schedule a convenient time for SolarCity to remove the (b)take an reasonable action to correct our default onto System from your Home at no cost to you. Y Y prevent our loss;any amount we pay will be added to 18. Applicable Law;Arbitration. the amount you owe us and will be immediately due; Power Purchase Agreement version 9.0.0,June 22,2015 885528 DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 PLEASE READ THIS SECTION CAREFULLY.ARBITRATION sought as part of a class action,class arbitration,private REPLACES THE RIGHTTO GO TO COURT, INCLUDING THE attorney general or other representative action are subject RIGHTTO A JURY AND THE RIGHT TO PARTICIPATE IN A to arbitration on an individual(non-class,non- CLASS ACTION OR SIMILAR PROCEEDING. IN ARBITRATION, representative)basis,and the arbitrator may award relief A DISPUTE IS RESOLVED BY AN ARBITRATOR INSTEAD.OF A only on an individual(non-class,non-representative)basis. JUDGE OR JURY. This means that the arbitration may not address disputes The laws of the state where your Home is located shall involving other persons with disputes similar to the govern this PPA without giving effect to conflict of laws Disputes between you and SolarCity. principles.We agree that any dispute,claim or The arbitrator shall have the authority to award any legal or disagreement between us(a"Dispute")shall be resolved equitable remedy or relief that a court could order or grant exclusively by arbitration. under this agreement.The arbitrator,however,is not The arbitration,including the selecting of the arbitrator,will authorized to change or alter the terms of this agreement be administered by JAMS,under its Streamlined Arbitration or to make any award that would extend to any transaction Rules(the"Rules")by a single neutral arbitrator agreed on other than yours.All statutes of limitations that are by the parties within thirty(30)days of the commencement applicable to any dispute shall apply to any arbitration of the arbitration. The arbitration will be governed by the between us. The arbitrator will issue a decision or award in Federal Arbitration Act(Title 9 of the U.S.Code). Either writing, briefly stating the essential findings of fact and party may initiate the arbitration process by filing the conclusions of law. necessary forms with JAMS.To learn more about BECAUSE YOU AND WE HAVE AGREED TO ARBITRATE ALL arbitration,you can call any JAMS office or review the DISPUTES, NEITHER OF US WILL HAVE THE RIGHT TO materials at www.jamsadr.com.The arbitration shall be LITIGATE THAT DISPUTE IN COURT,OR TO HAVE A JURY held in the location that is most convenient to your Home. TRIAL ON THAT DISPUTE,OR ENGAGE IN DISCOVERY If a JAMS office does not exist within 50(fifty)miles of your EXCEPTAS PROVIDED FOR IN THE RULES. FURTHER,YOU Home,then we will use another accredited arbitration WILL NOT HAVE THE RIGHT TO PARTICIPATE AS A provider with offices close to your Home. REPRESENTATIVE OR MEMBER OF ANY CLASS PERTAINING If you initiate the arbitration,you will be required to pay the TO ANY DISPUTE.THE ARBITRATOR'S DECISION WILL BE FINAL AND BINDING ON THE PARTIES AND MAY BE first$125 of any filing fee. We will pay any filing fees in excess of$125 and we will pay all of the arbitration fees ENTERED AND ENFORCED IN ANY COURT HAVING and costs. If we initiate the arbitration,we will pay all of JURISDICTION, EXCEPT TO THE EXTENT IT IS SUBJECT TO the filing fees and all of the arbitration fees and costs. We REVIEW IN ACCORDANCE WITH APPLICABLE LAW will each bear all of our own attorney's fees and costs GOVERNING ARBITRATION AWARDS.OTHER RIGHTS THAT except that you are entitled to recover your attorney's fees YOU OR WE WOULD HAVE IN COURT MAY ALSO NOT BE and costs if you prevail in the arbitration and the award you AVAILABLE IN ARBITRATION. receive from the arbitrator is higher than SolarCity's last 19. Waiver. written settlement offer. When determining whether your award is higher than SolarCity's last written settlement Any delay or failure of a party to enforce any of the provisions of this PPA, including but not limited to any offer your attorney's fees and costs will not be included. remedies listed in this PPA,or to require performance by Only Disputes involving you and SolarCity may be addressed the other party of any of the provisions of this PPA,shall in the arbitration. Disputes must be brought in the name of not be construed to(i)be a waiver of such provisions or a an individual person or entity and must proceed on an' party's right to enforce that provision;or(ii)affect the individual(non-class, non-representative)basis.The validity of this PPA. arbitrator will not award relief for or against anyone who is 20. Privacy/Publicity not a party. If either of us arbitrates a Dispute,neither of us, nor any other person, may pursue the Dispute in arbitration You grant SolarCity the right to publicly use,display,share, as a class action,class arbitration,private attorney general and advertise the photographic images, Project details, action or other representative action,nor may any such price and any other non-personally identifying information Dispute be pursued on your or our behalf in any litigation in of your Project.SolarCity shall not knowingly release any any court.Claims regarding any Dispute and remedies personally identifiable information about you or any data Power Purchase Agreement version 9.0.0,June 22,2015 [oil y 91 885528 MS. DocuSign Envelope ID:66DF815C-D980-461B-8B1E-7DC27A4FFF28 associating you with the Project location.You may opt-out of these publicity rights by giving LAs written notice and mailing it to:SolarCity Corporation,Attention:Publicity Opt Out,3055 Clearview Way,San Mateo,CA 94402. 21. Notices. All notices under this PPA shall be in writing and shall be by personal delivery,facsimile transmission,electronic mail, overnight courier,or certified or registered mail, return receipt requested. 22. Entire Agreement;Changes. This PPA contains the parties'entire agreement regarding the sale and purchase of power generated by the System. There are no other agreements regarding this PPA,either written or oral. Any change to this PPA must be in writing and signed by both parties.Only an authorized officer of SolarCity may execute any change to this Agreement on behalf of SolarCity. If any portion of this PPA is determined to be unenforceable,the remaining provisions shall be enforced in accordance with their terms or shall be interpreted or re-written so as to make them enforceable. REST OF PAGE INTENTIONALLY LEFT BLANK. Power Purchase Agreement version 9.0.0,June 22,2015 v� 885528 L'� DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and I acknowledge that I have received a TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement. DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Regina Moreira EXPLANATION OF THIS RIGHT. Doc-uSign/edJby: 24. ADDITIONAL RIGHTS TO CANCEL. Signature: IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL Date: 6/25/2015 THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after 6/23/2015. Customer's Name: Leandro De Oliveira If you don't sign this PPA and return it to us on or prior to Dmuftned by: 30 days after 6/23/2015,SolarCity reserves the right to Signature: 174-t== reject this PPA unless you agree to our then current pricing. Date: 6/2 5/2015 Power Purchase Agreement SolarCity approved Signature: Lyndon Rive, CEO Date: 6/23/2015 Power Purchase Agreement version 9.0.0,June 22,2015 [oil� •91 885528 1 �C �V DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 EXHIBIT 1(SOLARCITY COPY) NOTICE OF'CANCELLATION STATUTORILY-REQUIRED LANGUAGE Notice of Cancellation Date of Transaction:The date you signed the Power Purchase Agreement. You may CANCEL this transaction,without any penalty or obligation,within THREE BUSINESS DAYS from the above date. If you cancel,any property traded in,any payments made by you under the contract or sale and any negotiable instrument executed by you will be returned within TEN DAYS following receipt by the seller(SolarCity Corporation)of your cancellation notice,and any security interest arising out of the transaction will be canceled. If you cancel,you must make available to the seller(SolarCity Corporation)at your residence,in substantially as good condition as when received,any goods delivered to you under this contract or sale,or you may,if you wish,comply with the instructions of the seller(SolarCity Corporation)regarding the return shipment of the goods at the seller's(SolarCity Corporation's)expense and risk. If you do make the goods available to the seller (SolarCity Corporation)and the seller(SolarCity Corporation)does not pick them up within 20 days of the date of your notice of cancellation,you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller(SolarCity Corporation),or if you agree to return the goods to the seller(SolarCity Corporation)and fail to do so,then you remain liable for performance of all obligations under the contract. To cancel this transaction,mail or deliver a signed and dated copy of this cancellation notice,or any other written notice,or send a telegram to SolarCity Corporation,Document Receiving,6611 Las Vegas Blvd.S.,Unit 200,Las Vegas,NV 89119 NOT LATER THAN MIDNIGHT of the date that is THREE BUSINESS DAYS from the date you signed the Power Purchase Agreement. I,Regina Moreira,HEREBY CANCEL THIS TRANSACTION on [Date]. Customer's Signature: Customer's Signature: Power Purchase Agreement version 9.0.0,June 22,2015 885528 DocuSign Envelope ID:66DF815C-D9B0-461B-831E-7DC27A4FFF28 EXHIBIT 1(CUSTOMER COPY) NOTICE OF CANCELLATION STATUTORILY-REQUIRED LANGUAGE Notice of Cancellation Date of Transaction:The date you signed the Power Purchase Agreement. You may CANCEL this transaction,without any penalty or obligation,within THREE BUSINESS DAYS from the above date. If you cancel,any property traded in,any payments made by you under the contract or sale and any negotiable instrument executed by you will be returned within TEN DAYS following receipt by the seller(SolarCity Corporation)of your cancellation notice,and any security interest arising out of the transaction will be canceled. If you cancel,you must make available to the seller(SolarCity Corporation)at your residence,in substantially as good condition as when received,any goods delivered to you under this contract or sale,or you may,if you wish,comply with the instructions of the seller(SolarCity Corporation)regarding the return shipment of the goods at the seller's(SolarCity Corporation's)expense and risk. If you do make the goods available to the seller (SolarCity Corporation)and the seller;SolarCity Corporation)does not pick them up within 20 days of the date of your notice of cancellation,you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller(SolarCity Corporation),or if you agree to return the goods to the seller(SolarCity Corporation)and fail to do so,then you remain liable for performance of all obligations under the contract. To cancel this transaction,mail or deliver a signed and dated copy of this cancellation notice,or any other written notice,or send a telegram to SolarCity Corporation,Document Receiving,6611 Las Vegas Blvd.S.,Unit 200,Las Vegas,NV 89119 NOT LATER THAN MIDNIGHT of the date that is THREE BUSINESS DAYS from the date you signed the Power Purchase Agreement. I,Regina Moreira,HEREBY CANCEL THIS TRANSACTION on [Date]. Customer's Signature: Customer's Signature: Power Purchase Agreement version 9.0.0,June 22,2015 885528 DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 EXHIBIT 2 PERFORMANCE GUARANTEE AND LIMITED WARRANTY 1. INTRODUCTION This Performance Guarantee and Limited Warranty(this"Limited Warranty")is SolarCity's agreement to provide you warranties on the System you are hosting pursuant to our PPA. The System will be professionally installed by SolarCity at the address you listed in the PPA.We will refer to the installation location as your"Property'or your"Home." This Limited Warranty begins when we start installing the System at your Home. We look forward to helping you produce clean,renewable.solar power at your Home. 2. LIMITED WARRANTIES,PERFORMANCE GUARANTEE (a) Limited Warranties (i) System Warranty Under normal use and service conditions the System will be free from defects in workmanship or defects in,or a breakdown of,materials or components,for the full Term; s (ii) Roof Warranty All roof penetrations we make for your System will be watertight.This warranty will run the longer of(a)ten(10) years or(b)the length of any existing installation warranty or new home builder performance standard for your roof; (iii) Damage Waranty We will repair damage we cause to your Home,your belongings or your Property or pay you for the damage we cause,as limited by Section 6,for the full Term(except damages that result from our roof penetrations,which damages are covered for the first ten(10)years of the Term). Under each of these warranties SolarCity will repair or replace any damage,defective part,material or component or correct any defective workmanship,at no cost or expense to you(including all labor costs),when you submit a valid claim to us under this Limited Warranty. SolarCity may use new or reconditioned parts when making repairs or replacements.SolarCity may also,at no additional cost to you,upgrade or add to any part of the System to ensure that it performs accordingto the guarantees set forth in this Limited Warranty. Cosmetic repairs that do not involve safety or performance shall be made at SolarCity's discretion. (b) Performance Guarantee (i) Performance Guarantee SolarCity guarantees that during the Power Purchase Agreement Term the System will operate within manufacturer's specifications and if it does not that SolarCity will repair or replace any defective part and restore System performance. (ii) PowerGuide TM Solar Monitoring During the Power Purchase Agreement Term,we will provide you at no additional cost our PowerGuide Solar Monitoring Service("PowerGuide"). PowerGuide is a proprietary monitoring system designed and installed by SolarCity that captures and displays historical energy generation data over an Internet connection and consists of hardware located on Power Purchase Agreement version 9.0.0,June 22,2015 al�� 885528 Etio,. DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 site and software hosted by SolarCity. If your System is not operating within normal ranges,PowerGuide will alert us and we will remedy any material issues promptly. (c) Maintenance and Operation (i) General When the System is installed,SolarCity will provide you with a link to its Solar Operation Guide.This Guide provides you with System operation instructions,answers to frequently asked questions,troubleshooting tips and service information. SolarCity will perform all required System maintenance. ' (ii) PowerGuide PowerGuide requires a high speed Internet line to operate.Therefore,during the Power Purchase Agreement Term, you agree to maintain the communication link between PowerGuide and the System and between PowerGuide and the Internet. You agree to maintain and make available,at your cost,a functioning indoor internet connection with a router,one DHCP enabled Ethernet port with internet access and standard AC power outlet close enough and free of interference to enable an internet-connected gateway provided by SolarCity to communicate wirelessly with the system's inverter(typically this is 80 feet,but may depend on site conditions). This communication link must be a 10/100 Mbps Ethernet connection that supports common Internet protocols(TCP/IP.and DHCP). If you do not have and maintain a working high speed Internet line we will not be able to monitor the System and provide you with a performance guarantee or provide PowerGuide. Further,if PowerGuide is not operational,SolarCity will be required to estimate your power usage as set forth in the PPA. (d) Making a Claim;Transferring this Warranty (i) Claims Process You can make a claim by: A. emailing us at the email address in Section 7 below; B. writing us a letter and sending it overnight mail with a well-known service;or C. sending us a fax at the number in Section 7 below. (ii) Transferable Limited Warranty SolarCity will accept and honor any valid and properly submitted Warranty claim made during any Term by any person who either purchases the System from you or to whom you properly transfer the PPA. (e) Exclusions and Disclaimer The limited warranties and guarantee provided in this Limited Warranty do not apply to any lost power production or any repair,replacement or correction required due to the following: (i) someone other than SolarCity or its approved service providers installed,removed,re-installed or repaired the System; (ii) destruction or damage to the System or its ability to safely produce power not caused by SolarCity or its approved service providers while servicing the System(e.g.,if a tree falls on the System we will replace the System per the Power Purchase Agreement,but we will not repay you for power it did not produce); (iii) your failure to perform,or breach of,your obligations under the Power Purchase Agreement(e.g.,you modify or alter the System); Power Purchase Agreement version 9.0.0,June 22,2015 [oil 91 885528 *4 .= DocuSign Envelope ID:66DF815C-D980-461B-8B1E-7DC27A4FFF28 (iv) your breach of this Limited Warranty,including your being unavailable to provide access or assistance to us in diagnosing or repairing a problem; (v) any Force Majeure Event(as defined below); (vi) shading from foliage that is new growth or is not kept trimmed to its appearance on the date the System was installed; (vii) any system failure or lost production not caused by a System defect(e.g.,the System is not producing power because it has been removed to make roof repairs or you have required us to locate the inverter in a non-shaded area); (viii) theft of the System(e.g.,if the System is stolen we will replace the System per the Power Purchase Agreement,but we will not repay you for the power it did not produce); (ix) damage to your Home,belongings or property that results from our roof penetrations after the end of the Roof Warranty;and (ix) damage or loss to the System due to ball strikes. This Limited Warranty gives you specific rights,and you may also have other rights which vary from state to state.This Limited Warranty does not warrant any specific electrical performance of the System other than that described above. Snow or ice may accumulate on rooftops and on solar panels during snow storms.Accumulated snow or ice may slide or fall, resulting in property damage or bodily harm.If and when conditions safely allow you to remove accumulated snow or ice, you should do so to reduce the likelihood of excess snow sliding or falling. THE LIMITED WARRANTIES DESCRIBED IN SECTIONS 2(a)ABOVE ARE THE ONLY EXPRESS WARRANTIES MADE BY SOLARCITY WITH RESPECTTO THE SYSTEM. SOLARCITY HEREBY DISCLAIMS,AND ANY BENEFICIARY OF THIS LIMITED WARRANTY HEREBY WAIVES,ANY WARRANTY WITH RESPECT TO ANY COST SAVINGS FROM USING THE SYSTEM. 3. SOLARCITY'S STANDARDS For the purpose of this Limited Warranty the standards for our performance will be(i)normal professional standards of performance within the solar photovoltaic power generation industry in the relevant market;and(ii)Prudent Electrical Practices. "Prudent Electrical Practices"means those practices,as changed from time to time,that are engaged in or approved by a significant portion of the solar power electrical generation industry operating in the United States to operate electric equipment lawfully and with reasonable safety,dependability,efficiency and economy. 4. SYSTEM REPAIR,RELOCATION OR REMOVAL (a) Repair. You agree that if(i)the System needs any repairs that are not the responsibility of SolarCity under this Limited Warranty,(ii)the system needs to be removed and reinstalled to facilitate remodeling of your Home or(iii)the'system is being relocated to another home you own pursuant to the Power Purchase Agreement,you will have SolarCity,or another similarly qualified service provider,at your expense,perform such repairs,removal and reinstallation,or relocation. (b) Removal/Moving. SolarCity will remove and replace the System from your roof while roof repairs are being made for a payment of$499. You will need to provide storage space for the System during such time.Where permitted under the PPA, SolarCity will work with you to move the System to your new home as follows:SolarCity will conduct an audit of your existing Home and new home to determine if a move is commercially feasible. This audit will cost$499. If SolarCity determines that a move is commercially feasible,it will then move the System for an additional payment of$499.If we Power Purchase Agreement version 9.0.0,June 22,2015 885528 DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 reinstall your System;the Roof Warranty will restart at the completion of reinstallation and run for ten(10)years from reinstallation. (c) Return.If at the end of the Term you want to return the System to SolarCity under Section 17 of the PPA then SolarCity will remove the System at no cost to you. SolarCity will remove the posts,waterproof the post area and return the roof as close as is reasonably possible'to its original condition before the System was installed(e.g.ordinary wear and tear and color variances due to manufacturing changes are excepted). SolarCity will warrant the waterproofing for one(1)year after it removes the System. You agree to reasonably cooperate with SolarCity in removing the System including providing necessary space,access and storage,and we will reasonably cooperate with you to schedule removal in a time and manner that minimizes inconvenience to you. 5. FORCE MAJEURE If SolarCity is unable to perform all or some of its obligations under this Limited Warranty because of a Force Majeure Event, SolarCity will be excused from whatever performance is affected by the Force Majeure Event,provided that: (a) SolarCity,as soon as is reasonably practical,gives you notice describing the Force Majeure Event; (b) SolarCity's suspension of its obligations is of no greater scope and of no longer duration than is required by the Force Majeure Event(i.e.,when a Force Majeure Event is over,we will make repairs);and (c) No SolarCity obligation that'airose before the Force Majeure Event that could and should have been fully performed before such Force Majeure Event is excused as a result of such Force Majeure Event. "Force Majeure Event"means any event,condition or circumstance beyond the control of and not caused by SolarCity's fault or negligence. It shall include,without limitation,failure or interruption of the production,delivery or acceptance of power due to:an act of god;war(declared or undeclared);sabotage;riot;insurrection;civil unrest or disturbance;military or guerilla action; terrorism;economic sanction or embargo;civil strike,work stoppage,slow-down,or lock-out;explosion;fire;earthquake; abnormal weather condition or actions of the elements;hurricane;flood;lightning;wind;drought;the binding order of any governmental authority(provided that such order has been resisted in good faith by all reasonable legal means);the failure to act on the part of any governmental authority(provided that such action has been timely requested and diligently pursued); unavailability of power from the utility grid,equipment,supplies or products(but not to the extent that any such availability of any of the foregoing results from SolarCity's failure to have exercised reasonable diligence);power or voltage surge caused by someone other than SolarCity including a grid supply voltage outside of the standard range specified by your utility;and failure of equipment not utilized by SolarCity or under its control. 6. LIMITATIONS ON LIABILITY (a) No Consequential Damages YOU MAY ONLY RECOVER DIRECT DAMAGES INCLUDING THOSE AMOUNTS DUE PURSUANT TO SECTIONS 2(b)AND 6(c) UNDER THIS LIMITED WARRANTY,AND IN NO EVENT SHALL SOLARCITY OR ITS AGENTS OR SUBCONTRACTORS BE LIABLE TO YOU OR YOUR ASSIGNS FOR SPECIAL, INDIRECT,PUNITIVE, EXEMPLARY,INCIDENTAL OR CONSEQUENTIAL DAMAGES OF 1 ANY NATURE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. (b) Limitation of Duration of Implied Warranties ANY IMPLIED WARRANTIES,INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARISING UNDER STATE LAW,SHALL IN NO EVENT EXTEND PAST THE EXPIRATION OF ANY WARRANTY Power Purchase Agreement version 9.0.0,June 22,2015 [oil 91 885528 DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 PERIOD IN THIS LIMITED WARRANTY. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS,SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. (c) Limit of Liability Notwithstanding any other provision of this Limited Warranty to the contrary,SolarCity's total liability arising out of relating to this Limited Warranty shall in no event: (i) For System Replacement: exceed the greater of(a)the sum of the Monthly Payments over the Term of the Power Purchase Agreement and(b)the original cost of the System;and (ii) For damages to your Home,belongings and property: exceed two million dollars($2,000,000). 7. NOTICES All notices under this Limited Warranty shall be made in the same manner as set forth in the Power Purchase Agreement to the addresses listed below: TO SOLARCITY: SolarCity Corporation 305.5 Clearview Way San Mateo,CA 94402 Attention: Warranty Claims Telephone: 650-638-102 8 Facsimile: 650-638-1029 Email: customercare@solarcity.com TO YOU: At the billing address in the Power Purchase Agreement or any subsequent billing address you give us., 8. ASSIGNMENT AND TRANSFER OF THIS LIMITED WARRANTY SolarCity may assign its rights or obligations under this Limited Warranty to a third party without your consent,provided that any assignment of SolarCity's obligations under this Limited Warranty shall be to a party professionally and financially qualified to perform such obligation. This Limited Warranty protects only the person who hosts the System. Your rights and obligations under this Limited Warranty will be automatically transferred to any person who purchases the System from you or to whom you properly transfer the Power Purchase Agreement.This Limited Warranty contains the parties'entire agreement regarding the limited warranty of the System Power Purchase Agreement version 9.0.0,June 22,2015 R1��`�■ 885528 . DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 �■ �■ 885528 T7 DocuSign Envelope ID:66DF815C-D9B0-461B-8B1E-7DC27A4FFF28 885528 OWNER AUTHORIZATION Job ID: ©p Location: A P_1-D%0_1_J on D A f M A MML�_e_i (2 A as Owner of the subject property hereby authorize_ SollarCity Conn—IBIIIC 168572/ MA lLnc 1136 MR I to act on my behalf, in all matters relative to work authorized by this building permit application and signed contract. iiaVeofOwner: Date: _ I i _.. -... r... SO LAR..:T%,.CC-14' Massachusetts Dees Ment of Pualic Safety Board of 13widing Radutat+on►and Standards canoe CS-108515 JASON PATRY 821 STEWART DRIVE + :. Abington MA 02351 J.�i...�.�. ��{1+t a1►cti� G.s��+ue•+,�+�, 02/86/2019 ,. �r P,awaraunwrll� '. f'fcwers� OMce of Consumer Affairs&Business Relation 1wv,HOME IMPROVEMENT CONTRACTOR h Registration: 168572 Type:! Expiration: 3/8f2017 Supplement Q SOLAR CITY CORPORATION JASOIV PATRY � 24 ST MARTIN STREET BLD 2UNi g�- -- EA&LBOR000H,MA 01752 Underseeretsry i C� fC c } cC�llrl c� Office of Consumer Affairs d Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 , Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card Expiration: 3/8/2017 SOLAR CITY CORPORATION CHERYL GRUENSTERN ------- 24 ST MARTIN STREET BLD 2UNIT 11 - --------- MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. '7 Address Renewal Employment F_? Lost Card tfr .P ti to rig :•a�/f iI^71.,:;.Irir�rr.;r/[; a. • _ flicc of Consumer Affairs&Business Regulation License or registration valid for individal use only OME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: x '.t Office of Consumer Affairs and Business Regulation a egistration: 168572 Type: 10 Park Plaza-Suite 5170 Expiration:P 3/8/2017 Supplement Card. Boston,MA 02116 SOLAR CITY CORPORATION CHERYL GRUENSTERN �.. 3055CLEARVIEW WAY - ai _ SAN MATEO,CA 94402 Undersecretary -Not valid without signature i i The C'omtnonweafth ofMassachuseft Department of Industrial Accidents ,t` = Office of Anvesdgadens I Congress Street,Snide 100 Boston,MA 02114-20I7 www.mass govIdia Workers'Compensation Ltsurance Affidavit: Builders/Contractors/Electridans/Plumbers APPReant Informadon Pease Print Legibly Name(Business/Organiaation4adividual): SiDlafCCitty Corporation Address: 3055 Clearview Derive CiWState/Zip: San Mateo CA 94402 Phone M 888-765-2489 Are you as employer?Check the appropriate box: general contractor and I Type of project(required): 1.Q I am a employer with IQ� 4.40 ❑ I am a g full and/or * have hired the suit-contractors 6• ❑New construction employees� part-time).* 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. []Remodeling ship and have no employees These sub-contractors have B. ❑Demolition working for me in any capacity. employees and have workers' [No workers'comp.insurance comp_insurance. 9• ❑Building addition requixtd,] 5. [] We are a corporation and its 10.[]Electrical repairs or additions 3.❑ I ant a homeowner doing all work officers have exercised their 11.[]Plumbing repairs or additions myself[No workers'comp„ right ofexemption per MGL 12. Roof repairs insurance required.]t c,152,§1(4),and we have no ❑ � employees.[No workers' 13.I'I Other solar panels comp,insurance required] 'Any applicant that chcela box#I must also fill out the swdon below showing their wortmts'eorapmadda policy haft mlon. t Honaeowne rs who submit this affidavit indicating they are doing all work aml dun hire outside coo- -om mon submit a new affidavit indicating such. =Conuaorms drat check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. Cf the subcontractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employem Below is the policy and job site lnformatlon. Insurance Company Name: Liberty Mutual Insurance Comtsany Policy#or Self-izts.Lic. WA766D066265024 Expiration Date: 9/1/2015 Jab Site Address: 161 Ridgewood Avenue Ciry/State/tip: Hyannis,MA 02601 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to 51;500.00 and/or one-year imprisonment,as well as civil penalties its the form of a STOP WORK ORDER and a fine of up to 3250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the:Office of Investigations of the DIA for insurance coverage verification. 1 da hereby ce under the tts Wd arlttes o er' that the informadon provided above is true and conwL I June 3 ,2015 Phone#; 508.314.1581 Ojfl al use only. Do not write In this area,to be completed by city or town offlciaL City or Town: PermitUcense# Issuing Authority(circle one): 1.Board of Health I Building Department 3.CltylTown Clerk 4.Electrical Inspector 5,Plumbing Inspector S.Qtlter Contact Person: Phone#: I CERTIFICATE OF LIABILITY INSURANCE 77 M CERt*=TE 13 ISSUED AS A NATWER OF IM20RMAMN ONLY AND COIEFMa no RlO}II'e IJF'OH TEED CpAMCATli MOLAER.THIS GERT(RCAT11 f3M NOT AMRMATNELY OR NEC4ATTV MY AMEND,EXTEND OR ALTER THE MVERME Apt i}Y THE pdtJClls faEEM. TM C13iT BATE OF MURANCR ACES f1OT COfS4'I'1'AITE A CONTRACT OLTA 16N TW 189MG EHSURM(a)e Af/THMao REPRESENTATIVE OR PRODUCEt,AND THECERTIFICAT E HOLDM IA PORTAMr,. 3 the antFacub ham-Is art ADD}TIpNAL INSLK DQ on paffqtlea)mtW bo atldersled. It suvwmTlom I$WAIVOlk outieet to- the testae ead omediHons'ai tie POULT,eelula policies may mquire can e»domment A stal to et an This eeeSticdo dare eat eontsr rj&W in the caffiftete helder In tfhu ofsuch eadarssmentt l �f ttlSl(B ffi5Y1RN ICE EtERIRCE3 3t5CALASTA€ET,SUiifo t3Elp CAUFOWALIMSEN0.DISM0 A SAN AW CMW CA 2401 amom gRMA" NAM 891K i�i1ID6RVBJE-t4•f5 ._ _ vStmm A.L%*KuW Fie ftmw C" l' low ItlStlph pm9wo 4w $dial ty 6t��ye enEtueaRc: t#A •�7Uf 1NShce'JtD: e R18Effu<R COVERAGES CERTlf31CATS NUMBER: SEMM4402C&IR N •4 TIRS IS TO CER FY THAT THE POLICIES OF INSURANCE 1161 BELOW HAVE BEIf ISSUED TO THE INSURED NAWO ABOVE FOR THE POLICY PE MOD 24=ATEO. l4DTWITIMA1NI9NG ANY REQISREMMT,TERM OR CONITITIOff OF ANYCONrRACT OR OTHM OQCL9�M WITH RESPECT TO IA6flrH TifIS CERIMM MAY BE IBBUEO OR MAY PERTAIN,THE INSURANCE Ai�ROE>D BY THE P M10ES DESCRIBED HEREW IS SUBJECT TD ALL ME TE • E7CQAWN5 AID COi DITMS OF SUCH FOi.FCtES.LNfTS SHOM MAY HAVE BEEN REMMED BY PAID CERRNS, a RIMLM TMOPfgBVRAMM Imo.. A emomuA anY T tOBG2&'►014 09i0IST4i4 tF80ifIQLS E�I1piOCCceRRENCE? 6 1if106.0011 x eDlddesRe7ALe;FrRra LeADeeeTr =AGE awnwiltwtOgf00 a�OxuaAavmrwer • ta�000 f�itM.A47E i 2,4106,0lE1 G9&AC,GREGATEUVffAPPLmpETt iRaOesCTs.GOIibRX1FAOG i 2,GQo00 x x Loc A AMMDUM Llne lm AS2 66106 r044 eTAltrtDli 15 d ! 1Ai1i,90Q X AW AVFO 00V LV tKVJRV 1perperwnl ALL O*W-v GgCGLLM BODILY R WiK ALnV9 HDf(-0 tP ra"oe4 i R HIREDAIM35 X AtlM � : x ptlm Gamp MAED: i i1,9001SI.D0D UN1102ueLIAR oceu>: 0ka10WURREJ= 3 excm Luz J , AGSKOATE e i a f I {} BWORKIM 00w LUmu i 4 80=16STATLI. B UICRVARTHEREDIECUM!Y` WCi$51 E0i(IMf} 09101 M4 (IO9i/2Qt5 F..LE1CFfACCIDENt ti �NDERS=DEN N KIA 1.ilf>0,1100 auaftIwykl AI} ;9NCDEOUCABIE(f50001! ELDISEJI6E-EA6lIW 3 a e; u,,,Am Sewow i 6L PIAICYEfNif 2f d6ttCRiFT101eOF BPRtATeWe61t.00A1idUR/VSrELtiF.0 yN6d�A��AefArmef RNewrJa Skhod�1!enitsap,p f: fxfdenrA OthqutmCe. , CEFt71FIC;ATE CANCE" 8ffr7MAIWOFTHE^W"WWRM POLIGIININK WINGFLLM BRFORE SBIkItIeD.CJ19t4QZ IM EXPMAUM DATE THEREOF. QOEICE WLL 09 DRAffiRRn 91 ACCORUNN UM IM POLICY FROVIgEt1NS. AVTH6tfiriR/1fI�YEIIfA'fNe a!1llJ1Rf11pg1(iiRN}iigCCQfNb19 snd ACCFtia 28 t�117i 7lm ACOtiD noose 0 1589'm1q ACeORP CS.Ii�PO11tA"OO& Atl fig138 r WV@d. logo am ti1�9ced nmm of ACt?1iL3 E{ Version#46.4 --=a-A,S,v%1arGty. June 30, 2015 Project/Job #0261363 RE: CERTIFICATION LETTER Project: Moreira Residence 161 Ridgewood Ave Barnstable, MA 02601 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes= MA Res.Code,8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground Snow Load = 30 psf - MPl&MP2: Roof DL = 9.5 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL = 14.1 psf(PV Areas) -.MP3: Roof DL= 10 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL= 14.1 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.18757 < 0.4g and Seismic Design Category(SDC) = B< D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing'structure is adequate to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res. Code, 8th Edition. Please contact me with any questions or concerns regarding this project. OF Mgss O,yG q HUMPHREY K. rt1 O KARIUKI _ U STRUCTURAL to Sincerely, Digitally signed by Humphrey oP, NO.51933 Kariuki �FG/STER�� Humphrey Kariuki, P.E. Date:2015.06.30 04:34:08-04'00' �`rS�ONAL ENG\� Professional Engineer T: 443.451.3515 email: hkariuki@gmail.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ ROC 243171,CA CSLB 88111114,CO EC 11141,CT HIO 0632778,DC HIC 71101486,DC HIS 71111141111,HI CT-29770,1,1A HIC 168512,MD 11NIC 128948,NJ 13V110618060o, OR CCB 180498,PA 077343,TX TDLR 27006.WA GCL SOLARC'91907 0 2013 SoIarQty.All,,ghta m—ed. - 06.30.2015 SolarCityPV System Structural Version #46.4 Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: Moreira Residence AHJ: Barnstable Job Number: 0261363 Building Code: MA Res. Code, 8th Edition Customer Name: Moreira, Regina Riccardo (Son) Based On: IRC 2009/ IBC 2009 Address: 161 Ridgewood Ave ASCE Code: ASCE 7-05 City/State: Barnstable, MA Risk Category: II Zip Code 02601 Upgrades Req'd? No Latitude/ Longitude: 41.660624 -70.281231 Stamp Req'd? Yes SC Office:I Cape Cod PV Designer:I Mikhail Gofman Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.18757 < 0.4g and Seismic Design Category (SDC) = B < D 1/2-MILE VICINITY MAP 40 A ; f 0 Cz 28 L,'11! •C -eMassGIS, Commonweallth -Us EPEA, USQA Farm Service Agency161 Ridgewood Ave, Barnstable, MA 02601 Latitude: 41.660624, Longitude: -70.281231, Exposure Category: C STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP1 &MP2 Member Properties Summary MP1 &MP2 . Horizontal Member Spans Rafter Pro erties Overhang 0.49 ft Actual W 1.50" Roof System Pro erties San 1 10.94 ft Actual D " _5.50" Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofing Material Comp Roof San 3 A 8.25 in.A2 Re-Roof No Span 4 S. 7.56 in.A3 Plywood Sheathing Yes S an"5 I 20.80 in.A4 Board Sheathing None Total Span 11.43 ft TL Defl'n Limit .120 Vaulted Ceiling &V, -No 1.00;ft`,'%IMI k,Wood Species, iffYmtW'SPF t- Ceiling Finish 1/2"Gypsum Board PV 1 End 11.08 ft Wood Grade #2 Rafter Slope 300 PV 2 Start u � F4 `,875 psi Rafter Spacing 24"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing At Supports PV 3 End Em;,, 510000 psi Member Loading Summary Roof Pitch 7 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 9.5 psf x 1.15 11.0 psf 11.0 psf PV Dead Load `:" PV-DL 10% sf>;: x 1:15 "u ;" 15 psf Fl Roof Live Load RLL 20.0 psf x 0.85 17.0 psf Live/Snow Load LL SL1,2 30.0 psf x 0.7 1 x 0.47 21.0 psf 14.1 psf Total Load(Governing LC TL 32.0 psf 28.5 psf Notes: 1. ps =Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)pg; Ce 0.9,Ct=1.1,IS=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CF Cr D+ S 1.15 1.00 0.57 1.3 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Load Combo Shear Stress 52 psi 0.5 ft. 155 psi 0.33 . D+ S Bending(+)Stress 1348 psi 6.0 ft. 1504 psi 0.90 D+S Bending (-) Stress -16 psi 0.5 ft. -864 psi 0.02 D+S Total Load Deflection f.0.84 in. 1, L1181 _1 6:O ft.". 1.26 in. 120Y � :y. 0.66 ORT D+S CALCULATION OF DESIGN WIND LOAM-:-P1 &MP2 Mounting Plane Information Roofing Material Comp Roof _ PV,Syste_m Type_ _ µSolarGity SleekMountTM Spanning Vents No " Standoff Attachment Hardware " Com M nt Tvae C A— Roof Slope 300 Rafter Spacing 24"O.C. _ Framin Type Direction Y-Y Rafters ��_ Pullin,SpacingX-X Purlins Only_ �„, -- -NA - - Tile Reveal Tile Roofs Only NA Tile Attachment_System z:: °�--7 7 Tle Roofs_Only_- NA T, StandingSeam ra Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method lly/ 3.r _ ", µ°°- PartiaFully Enclosed Method , Basic Wind Speed V 110 mph Fig 6-1 Ex osure Cate o _ ` u,:° K C?° `v _Section 6.5.6.3 P. -- g_ry .. _. _ a _ - -- Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft ~Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 .�Topographic Factor {jm.. �.,� d K rt °' , g�.w,_" �1.00 °' =��r�r °` —S_ection 6:5_7 __ Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(VA 2)(I) Equation 6-15 24.9 psf Wind Pressure Ext. Pressure Coefficient U GC u -0.95 Fig.6-11B/C/D-14A/B Ext:°:Pressure Coefficient' Down GC, Dow �a0.87-- " x-:"' Fig.6-11B/C/D-'14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure U -23.6 psf Wind Pressure Down 21.8 psf ALLOWABLE_STANDOFF SPACINGS 7. 77.7 X-Direction Y-Direction Max Allowable Standoff Spacing ,Landscape 72" 39" Max Allowable Cantilever" Landscape ,,, 24"_ _ NA Standoff Configuration Landscape Staggered Maz Standoff Tributary,'Area „_�_ "rTrib ,___ -IM PV Assembly- Dead Load W-PV 3 0 psf ,m., � Net Wind_.Uplift..at Standoff, T actual" 434 Ibs Uplift Capacity of Standoff T-allow 500 Ibs _ Standoff Demand/Capacity DCR 86.9% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever, Portrait _ P :. 17' '' NA - - ---. - _.__-._ Standoff Configuration Portrait Staggered Max Standoff Tributa-ry,Area Tribe 22 sf _ �___ _ PV,Assembly Dead Load W-PV 3.0 psf Net Wind_Uplift_at_Stan doff_` T actual_ _ -484 Ibs Uplift Capacity of Standoff T-allow 500 Ibs' Standoff Demand Ca aci � •RCR.� "� �,96r7%• :�. r � STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK-MP3 ` Member Properties Summary MP3 Horizontal Member Spans Rafter Pro erties Overhang 0.49 ft Actual W 1.50" Roof System Properties San 1 7.09 ft Actual D 5.50" Number of Spans(w/o Overhang) 2 San 2 0.82 ft Nominal Yes Roofing Material Comp Roof San 3 A 8.25 in.A2 Re-Roof No Span 4 S. 7.56 in.A3 PI wood Sheathing Yes San 5 Ix, 20.80 in.A4 Board Sheathing None Total Span 8.40 ft TL Defl'n Limit 120 Vaulted Ceiling No PV IStart._.. 1.08 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 7.75 ft Wood Grade #2 a.PV,2 Start;,x$ rt �:F 875 si Rafter Slope s ff 300 b f Rafter Spacing 16"O.C. I PV 2 End F„ 135 psi :Fop Lat Bracing Full PV,3'Start E s* '' 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loading mary Roof Pitch 7 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.0 psf x 1.15 11.5 psf 11.5 psf PV Dead Load PV-DL 3.0 psf x 1.15 3.5 psf Roof Live Load RLL 20.0 psf x 0.85 17.0 psf Live/Snow Load LL SL1'Z 30.0 psf ' x 0.7 1 x 0.47 21:0 psf 14.1 psf Total Load (Governing LC TL 32.5 psf 29.1 psf Notes: 1. ps=Cs*pf;Cs-roof;Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(CO(IS)p9; Ce=0.9,Ct=1.1,IS=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CF Cr D+ S 1.15 1.00 1 0.80 1.3 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacitv DCR Load Combo Shear Stress 34 psi 0.5 ft. 155 psi 0.22 D+S Bending + Stress 229 psi 3.3,ft. d,. 1504 psi 0.15 D+S Bending - Stress -343 psi 7.6 ft. -1203 psi 0.29 D+ S Total Load Deflection 0.05 in. 2095 3.6'ft.` 0.82 in." 120 _ ° 0.06 t" :'" -'D+S E [CALCULATION OF DESIGN-WIND LOADS MP3 Mounting Plane Information Roofing Material Comp Roof PV System_ .,Type , .,. � SolarCitySleekMountT" ' M; _. M1 .,„. Spanning Vents - No Standoff Attachment Hardware Comn Mount Tvne C Roof Slop�e 300 , � ._.��_ Rafter Spacing �_ _ i _ 16"O.C. __ _ _ FramingType Direction Y-Y Rafters Purlm Spacing. _X-X Purlins,Only•� � NAi Tile Reveal Tile Roofs Only NA � Tile Attachment S stems afrz°tip Tile Roofs OnlYIL Standin Seam/Trap Seam/Trap Spacinq SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind,Design,Method Partially/Fully_.Enclosed Method_ Basic Wind Speed V X it C k Fig 6 1 Exposure_Cate9ory "" .... -. n Section Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Hei ht h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topog phic Factor Krt-_,®_�. .� _ _.. 1.00 °.� _ Section 6.5.7 _ Wind Directionality Factor Kd 0 85 Table 6-4 Im ortance Factor . :,I x � ,.:. 1.0t° trTable 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 24.9 psf Wind Pressure Ext. Pressure Coefficient U GC u -0.95 Fig.6-11B/C/D-14A/B Ext, Pressure Coefficient Down GC DoWn r.° „ :+ 0.87 Fig.6-11B/C/D-14A/B Design Wind Pressure p p= qh (GC ) Equation 6-22 Wind Pressure U 23.6 psf Wind Pressure Down 21.8 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing _Landscape 64" 39" Max Allowable,CanVRIever' _ __Landscapes s , ��_ 24" = � N'A� Standoff Configuration Landscape Staggered Max,Standoff Tributary.Area_ Trib 17 sf PV Assembly.Dead Load W-PV 3.0 psf Net Wind.Uplift at Standoff- T-actual_ -386 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand Ca aci -. DCR 77.2% " X-Direction Y-Direction Max Allowable Standoff_Spacing Portrait 48" 66" _ Max Allowable Cantilever �_Portrat„r - P17" _ NA_ Standoff fi uration Portrait Staggered _ Max Standoff Tributary,Area Trib - _22 sf _ PV Assembly Dead Load W-PV 3.0 psf Uplfa Standoff Tatua bsNetWind, Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand Ca aci DCR. 7— - 7 1 "pr96.7% 7 Parcel Detail Page 1 of 3 r 4.�.._.._'w:.._f.. _.. ...w»......-....wW.......+.'.ar.M.+?., Logged In As: Parcel Detail Thursday,May 3 2012 Parcel Lookup Parcel Info Parcel ID 328-104 I DeveloLoot[EOf 24&25 Location 1161 RIDGEWOOD AVENUE Pri Frontage Sec Road I Sec Frontage village HYANNIS Fire District IHYANNIS I Town sewer exists at this addre s I Ye Road Index F1369 �-V 11 Interactive . a ' Map Owner Info Owner IDEOLIVEIRA, LEANDRO EI Co-owner %oDEOLIVEIRA, LEANDRO E&MOREI RA, Streetl 1161 RIDGEWOOD AVENUE I street2 I City HYANNIS I State AMAI Zip 02601 Country Land Info _ Acres 0.33 Use Single Fam MDL-01 Zoning 9F Nghbd 0104 Topography Level �� Road I Paved I Utilities JAII Public,Gas I Location Construction Info Building 1 of 1 Year Roof Ext Built 1952 I struct Gable/Hip wall Wood Shingle Living Roof AC Area 884 Cover Asph/F GIs/Cmp TypeNone � Style Ranch I Int Plastered I Bed 14 Bedrooms �I Wall Rooms a Model Int Bath Residential Floor Carpet Rooms 2 Full Grade Average Minus I Type Hot Air I Total Rooms f' --- �I Stories 11 Story Fuel Gasea F ation Mixed J Gross 1500 Area_ Permit History http://issgl2/intranet/propdata/ParcelDetail.aspx?ID=27831 5/3/2012 • Parcel Detail Page 2 of 3 Issue Date Purpose Permit# Amount Insp Date Comments 02/15/2008 Other 200800450 $5,000 08/05/2008 00:00:00 APTX OVR GAR 06/12/2007 Detached Garag 20061192 $40,000 05/03/2007 00:00:00 26X26 06/05/2006 Remodel 20060103 $40,000 05/03/2007 00:00:00 GAR FIN 04/01/1989 B32755 $500 04/15/1991 00:00:00 HY SHED 03/01/1977 IB18996 $0 01/15/1979 00:00:00 HY ADD'N Visit History Date Who Purpose 03/25/2011 00:00:00 Robin Benjamin Bldg Permit Completed 05/26/2010 00:00:00 Denise Radley Change of Address 08/05/2008 00:00:00 Mike Keating Meas/Est 01/15/2008 00:00:00 John Greene In Office Review 05/03/2007 00:00:00 Martin Flynn Bldg Permit Completed 03/26/2001 00:00:00 Ism Meas/Listed-Interior Access - Sales History Line Sale Date Owner Book/Page Sale Price 1 112/30/2011 DEOLIVEIRA, LEANDRO E 25970/293 $177.000 2 12/20/2007 HASKELL, BRUCE T&BARBARA M 22559/147 $1 3 06/15/1985 BROWN, BARBARA M 4565/019 $1 4 04/23/1976 BROWN,THOMAS E&BARBARA M 2328/127 $16,800 5 02/21/2012 1 DEOLIVEIRA, LEANDRO E&MOREIRA, REGINA 26092/208 1 $1 - Assessment History Save# Year Building Value XF Value OB Value Land Value Total Parcel Value 1 2012 $66,900 $10,700 $53,600 $68,100 $199,300 2 2011 $83,200 $0 $27,200 $68,100 $178,500 3 2010 $83,100 $0 $28,300 $104,700 $216,100 4 2009 $80,500 $0 $21,900 $141,400 $243,800 5 2008 $87,500 $0 $300 $147,300 $235,100 7 2007 $87,400 $0 $300 $147,300 $235,000 8 2006 $70,800 $0 $300 $148,400 $219,500 9 2005 $66,500 $0 $300 $114,300 $181,100 10 2004 $55,700 $0 $300 $80,700 $136,700 11 2003 $47,300 $0 $300 $30,700 $78,300 12 2002 $47,300 $0 $300 $30,700 $78,300 13 2001 $49,100 $0 $200 $30,700 $80,000 14 2000 $42,600 $0 $100 $23,400 $66,100 15 1999 $42,600 $0 $100 $23,400 $66,100 16 1998 $42,600 $0 $100 $23,400 $66,100 17 1997 $38,100 $0 $0 $20,100 $58,500 18 1996 $38,100 $0 $0 $20,100 $58,500 19 1995 $38,100 $0 $0 $20,100 $58,500 20 1994 $39,800 $0 $0 $24,100 $64,200 21 1993 $39,806 $0 $0 $24,100 $64,200 22 1992 $45,300 $0 $0 $26,800 $72,400 23 1991 $50,600 $0 $0 $43,500 $94,800 http://issgl2/intranet/propdata/ParcelDetail.aspx?ID=27831 5/3/2012 KF a a s a � �sr.f.s��s ' '4 .N! ^fi ` s 72d4j a.+ dE�t lo- ,(yp� t� s � q fit ,a ���-�" � •" � �A�� , �� t m sT' 1 ors.ar � -. 05(03200 ten, s e ' I I,foa- �a� a,° a lAt4 Ift -INv m ywr,e T� r Y ara :r n ♦'t' ke Mn ��9% € 08/05/2008 s� -., Coyle, Brenda From: Coyle, Brenda Sent: Thursday, May 03, 2012 3:00 PM To: Dabkowski, Cindy Subject: Amnesty Hello Cindy, Just to make you aware the property at 161 Ridgewood Avenue has been sold on 12/30/2011, owner was Bruce and Barbara Haskell, new owner Leandro DeOliveira. Comprehensive Permit 2007-091-Brown should be rescinded. Thank you, Brenda Coyle 1 �F'THE Tn Town of Barnstable Regulatory Services Thomas F. Geiler,Director * 1AMSPABM • MA & Building Division i639' iOrEo Mop a Tom Perry, Building Commissioner 200 Main Street, Hyannis,MA 02601 Office: 508-862-4038 Fax: 508-790-6230 November 29,2011 Kathy Vasel Reliant Mortgage Company 39 Main Street Salem,NH 03079 Re: Accessory Apartment Status Inquiry Property ID: Map 292 Parcel 276 Locus: 161 Ridgewood Ave,Hyannis Zoning: Single Family/WP Overlay Dear Ms Vasel; In response to your inquiry concerning the accessory apartment over the garage located at 161 Ridgewood Ave, please be advised that the property is located in the Single Family zone and therefore accessory units are only permitted by an appropriate form of zoning relief. The property in question currently has a comprehensive permit for an affordable accessory unit. This permit expires with the conveyance of the property and subsequent owners must apply to have a permit issued in their own names. Currently,the following two options are offered to qualified applicants as follows: • Family Apartment—Available to year round residents in owner-occupied properties for family members related by blood or marriage, all parties must be year round residents. Detached units require a special permit. • Amnesty Unit—A Comprehensive Permit is available to year round residents in owner- occupied properties containing an accessory unit created prior to the year 2000. If granted,these are affordable units and are not to be rented to family members. The landlord must abide by the rental schedule and tenants must meet the affordability criteria as outlined in the Amnesty program. Program participants are subject to yearly monitoring in order to confirm the eligibility of all residents Feel free to call me in the event that you require additional information. Sincerely, Robin C. Anderson Zoning Enforcement Officer l ' - Page 1 of 2 Anderson, Robin From: Kathy Vasel 978-502-2998 [GetYou rMtg @charter.net] Sent: Monday, November 28, 2011 2:10 PM C To: Anderson, Robin Subject: 161 Ridgewood Ave Hi Robin, Thank you for your help. You can attach and email me the form needed or fax ATTN: Kathy Vasel/ Oliviera at : 603-870-0977. Something from the Town on letterhead about the zoning and that the apartment is allowed for 161 Ridgewood Ave in Hyannis/Barnstable. I have copied my processor and brother's client to keep them in the loop. Thank you for your help. I'm never too busy for your introductions& promise exceptional service to you or someone you may know. My goal is to create another raving fan by expanding each client's wealth. Taff Care, Xatky`Ilasef MLO#50076 / getyourmtg@chartes.net / 978-502-2998 / FAX:603-870-0977 Purchase Specialist * FHA Condo Approvals* New Construction&Renovation * Referrals Welcome Kathy Vasel ° lci Licensed Mortgage Banker � . a s ► 978 502- ...`tiv dc6me, P: tin ( ) 2998 kvaselCDreliantloan.com F: (603) 870- NMLS ID: 50076 0977 39 Main Street, Ste 101 Salem, NH • 03079 My vCard State License Numbers: MA-ML050076, NH-NH50076, MA Lic.#MC1775- CT Lic.#10182,10183- RI lic.#20011277LB;ME Lic.#SLM5764;VT Lic.#5469; 0491 MB. New Hampshire Mortgage Banker License Number 8503-MB as licensed by the New Hampshire Banking Dept.. Unique NMLS ID#1888 11/28/2011 l Coyle, Brenda From: Dabkowski, Cindy Sent: Wednesday, July 27, 2011 10:57 AM To: Coyle, Brenda Subject: RE: Amnesty Program Thank you for the heads up- Cindy -----Original Message----- From: Coyle, Brenda Sent: Wednesday,July 27, 2011 10:50 AM To: Dabkowski,Cindy Subject: Amnesty Program Importance: High Hi Cindy, Just to make you aware we had a realtor in the Building Dept. this morning informing us that the property at 161 Ridgewood ave., Hyannis is for sale. New owner will have to go to ZBA for new permit. Thank you, Brenda Coyle Building Division Assistant 1 °Ft Town of Barnstable Regulatory Services * BARNSfABLE, MASS. Thomas F. Geiler, Director �A s63q. rF039 0. Building Division Thomas Perry, CBO, Building Commissioner 200 Main Street, Hyannis, MA 02601 www.town.barnstable.ma.us Office: 508-862-4038 Fax: 508-790-6230 March 11, 2008 Barbara Brown Haskell 161 Ridgewood Avenue Hyannis, MA 02601 Re: Amnesty Apartment 161 Ridgewood Avenue Dear Ms. Brown Haskell: Enclosed is the Certificate of Occupancy for your Amnesty apartment. We have prepared the Amnesty Certificate of Compliance and forwarded it to the Amnesty Program Coordinator. Sincerely, Lois Barry Division Assistant Enclosure amnco �,.d t ,'n w;.. '/Y5u'a.'°+.�f7„'tin .:r. .... ,;-P��^";'.*—F�'1'•.r.`?f -,Y "':._:""" ... '"F .::.p, .. _.w =.. �. ;m. v..:; Aw:Y'. ua rat", ,'w Y.%. .-C r.c :±>...m .-M...'q x x,':. .. �;:E' . .. t,:. ,aa ........ rc> r- ,.: :ry h-x`.,... 5 .-ts `*`e ':. ..�,; :.s:kt .�. yn ti:.,,X4e..Nk . - .,'t. ...,.-2. 9:..,k.ar . :.:;.-. , ,�.,. ,4. :.,., ]'�:.: a'.E> ..,:r "., _ uz:," -.r r .gym ,..,.r I . ,,,,.. $- ,,..r.. r',t .. :., ....,> T. ..="'1` - „' --4 sr..: :.� �. - \... .a 74.s. u4.. b. r. tR. ^u",.° JL Y.,N•;,.i:- x+:.., :.. }.<v.1 �. ..� ,..... r -¢. s ,,. s �5 :`xr � A. .f-' �.a „ ✓x r_. ,s '.'3i-n-:N, 3, Sr..i•-: -..(..'-`'n4't. ,. ...1 .:,...Y :.....,. ,. " i 5..- of 1:'24. 1 2,.r, ... �,. .,; . ..-.n,:. .- a..:.... .;��.: -^ ...a•'.,r" i..,:...F r":.. .:° r ..:a� 2. 1,z. .r :.,r.: 9 .ra.�J . rt':.. r, , 1 r .. - .,.... .: r.—1. t yr 3: ":'i ��� .cr � '<�v � h..�; �,..,��'�c£, ,tom �-. ,.--.,.. 4 .,9 ., ,.i.:r ."+-..:.�+' -..r.}L� x. 1 - `��" ,. :...: k £ )T -''" "11 .:3+( ! '�' F h .p".".G+:yn..�..'},,, 'i h'I. f ..'! .x y ..... :. 1,,at'�y �..,,a, P t -,,:- a:--'k -'} ! �+3 a f 1..x. P '-^t'x::' ` ,a1r. K 9j .d' r 9.. $`4,.i:°r. F �,y *.. .. Ra -{.an... ':. y:... -...y...'_ '4 .: ..y.i.. .>, $,. 3C,a, ,,-fT K 3',. �w1 i4 ,t` .+.:y r y y,-.. ,_.'. '.1 ' P:"-. ., ,+'L'a.aa ....-s./ v.',:..,y. ..ye ., y - ,-•1 k a .n-t-n �; k. C t :. 5 i f b. -��'nh&�. . 11 f - i•f:.. ..1. 9 a � ."§l:.. ,.Y r .r ... - r \ :.:-1. C b rl' A.',x; M .rt.A R '.. ...,.. ...;.-i-..,:. .a;.. r., .:..r,. 's„ z.-Fr_, .' _ ,«..rt r.. r ,`a;'� ,'�V , x *� ' ,. n ..<T J .. ..„ fi,-.,.:,3 .,4c .ia ,-,. :Y;:: ..1,6. >.. ,._:,.5 ', r 'q. ?, :fr r. w y• s.. .J,+ _ „fit 9 ..»� 4_ . .�. e, +.e,r,.. 'ca'.,.: .a� xu. 't3 1,.:. a.. a r s .. A; S w„ M1 s ....r .�:. ,y ....,. ,.zr '`.::' a...s 4 ,;4... .e e i 'Ykrt,«, mr .;.� ,.:,...,, „1y, jw w n -ew ,::.n. r...:. ,k.. _ E a s^�f'f a .K §w, .r r. r-, ai, 'r t ..<:'... .c:.»._ ,.,.... ,:, b ., ::;:', ,> ;rr+',, 3,., .� f, �W a 't px}, -,.�r s.. - .: > :,; , .::. t. �,. } E , o:. a 4a.. e,Yr" k,U,. s w;.;a4 F# "i' L' ° a:. RZF ;i xt"s:. ,Y tN ,�� so,.':.i -z. „.n ,., •, ::�: ,.,,.n.. a, ;,;:a f. .:`,* I :^ A ...;v..,,. a a". ,;v' x„<.c:'.,.. '�. ,i? t` v d & {.: Y., C..7 ,r}, ,r�,1, ua ,;...:y, ;'" :» ,u�».., v .,. v- .. so-: , ,. ., ,,, .... ., d j 3f.3;d 5 a d .'r� S:. 1 a o r Amnest Pro rare d. .„.._ .,k,'",,,. :c>.„,. i �, �:.,.. ,r ,r.. ,_, ,,::.� r F 't rtr.,t s. r,.xr...x., ,.,.y d. ,., g. � '.E r......... .a, ,t:, ;:. .:+. z t^ -,,< '...!: :.. ,:A. n7 h x.: a 4, .+.. 5 r,'t✓1, n,,.x.: r .s ,. -.w :::, r. s,ta.,. w :,-v.:1 a ,x'r, t ,..,.::v "n n "i :i i. ,, i ata: ,.Y.. rr'n'yL G:.,. i �, .^ y .x>, a'N v '£ 4a,..'h f .4 ". ' ,u x ,:<:,, 5 7::,t s - xf r n '�y ".w X t s'' T v a.' x �J t yk Y t:; r , is � .S a.: ;::'0 ¢ Y. 1.A_', ,� 4 '" ,"f P.°.� 1' :, :1 ir. f.1:.fi,:..` L.:e a: � �, 1 'F' lF l i Y 1 w E , 4: - 'F `� 1¢yj xK �,, 1 y y n HeI rn m k ff r w j � . H Uto a e :a o dable housin oss�b�le. , x m p g g p t'n �� � i ;Y' - i F •1L `` "� - ,+_. d ✓. A 'v J Ff Si.Y A � - J" A.lT R. 1. ,::t Ss ' rd k r ✓ r Y'tr r �' > n,z'` 'L t -:s'%e, :K1 a ,� - Y ru 3 k' *, i a .:'.b 1, `M1"iII' :'% _y i >A `� .d [ - ) 4" 4 f'..Y ? t,XP 'xS h t S 1..db 4 4' t i b a'� t '.. a ti { ,�S �M 3 r AN A '•yi4 y 6 , ..-,,,1 I.I�7�.,aI,z1..I 4,�,-.r-,�.4,�-1,,I1 I�1 r I .1 .-"1I-I.....b...IiI 11—I,,-I.:_.I 1",���,:-.,�."�i j_r,�,:;,,�,, :I,-"-��1,".,"I I I I-I I�_I 2I.�1.�z I I�.,::I-1,I*-,I��,:I�,��,,b,�_.'.�.��"4--,, �'-�,��'.,,,,,�-�-�,"�.-_,�_.�r��,I�_-, ` M v a '® WI2 0 , �L�r° StG� .r",,�_'b P','"t,��,�,�1t�-"'..�1:,"�.�j"�,,,,;,�0�,_--�b_,1--,-,--_,_���.-";,,,,',",,",."-�,._"-. - - - :3 5 , e �,;,,?-I��`��,'�4,�i,%,,,b 7-b�,,�,:,�.;,,,%,;,-"_,�,'�, fir' _ r �� t y -�—�. L221.1. ., _ ti ,. .. .. ....._._- _ gym- ...+.��:^- �.��` G X ,K x + f' 11 ! fY , F " �d �,7::,�',",,� . , - , , , ".r, :. 4e i 4 � x �_ I . III..�1I I..�I..I.I..,,,.,�.7��-�..I......;b�I I.,r,:,,,.,b�,_,I I,.I......��Ib��I�4..:�.:.,.I.).I.I,.I;I,:�I.II.:.,I��I....I..i-r-.I�I I...1��,.,�-..�.�.2�I.'b��,.,�.I�,.,.,.-I,-.-..,,.,�.I-,�.I,.I-.I.I:�I.I�-�.�I..,i,�i-�I�...,-:�I�-i1.. ,.�1.1I.�1.,I�I.,b I..t I.�- CI I:..�1II I.I��_.. ertificate of Complla"� nee � � I'.`.-,t.�...�,-..-,.";I1:,-��1,1,,.''�.. .This certificate indicates acceptable minimum habitable requirements per Massachusetts State�Buildmg�.Code ,,�',b,,.,.,.;.�m�., �+ and Town of Barnstable zoning ordinances ui accordance with the Amnesty.program , Owner': Barbara Brown;Haskell - :, Location - ..161 Ridge W A enu,;,I�" e; Hyannis,'MA . I. . Unit Eapacity One roomµ of to exceed two eo le Inspector �k 11; I I . _ . �� I I � � : . I. II It: 1VI/P No. 328104 3/11/200.8 Town of Barnstable do Building Department - 200 Main Street ASTABLE. * Hyanni 1639. s, MA 02601 MASS. $ (508) 862-4038 �� Certificate of Occupancy Application Number: 200800450 CO Number: 20080044 Parcel ID: 328104 CO Issue Date: 03/06108 Location: 161 RIDGEWOOD AVENUE Zoning Classification: SINGLE FAMILY RESIDENTIAL DIST Village: HYANNIS Gen Contractor: PROPERTY OWNER Permit Type: RC00 CERTIFICATE OF OCCUPANCY RES Comments: AMNESTY APARTMENT ISSUED TO BARBARA BROWN HASKELL Building Department Signature Date Signed a INEr y TOWN OF BARN STABLE , Building Application Ref: 200800450 BARNSTABI.E, * Issue Date: 02/15/08 Permit 9 MASS. �A i639• Applicant: BROWN,BARBARA M Permit Number: B 20080312 rFD MA'I p Proposed Use: SINGLE FAMILY HOME Expiration Date: 08/14/08 Location 161 RIDGEWOOD AVENUE Zoning District SF Permit Type: AMNESTY W/CONSTR RESIDENTIAL Map Parcel 328104 Permit Fee$ 25.00 Contractor PROPERTY OWNER Village HY_ANNIS App Fee$ 50.00 License Num Est Construction Cost$ 5,000 Remarks APPROVED PLANS MUST BE RETAINED ON JOB AND CREATE 1 BEDROOM APT DYER EXISTING DETACHED GARAGE THIS CARD MUST BE KEPT POSTED UNTIL FINAL INSPECTION HAS BEEN MADE. WHERE A CERTIFICATE OF OCCUPANCY IS REQUIRED,SUCH Owner on Record: BROWN, BARBARA M BUILDING SHALL NOT BE OCCUPIED UNTIL A FINAL Address: P O BOX 2247 INSPECTION HAS BEEN NLAAE. HYANNIS, MA 02601 Application Entered by: PR Building Permit Issued By: THIS PERMIT CONVEYS NO RIGHT TO OCCUPY ANY:STREET,'ALLY OR SIDEWALK OR ANY PART THEREOF,EITHER TEMPORARILY OR PERMANENTLY:. ENCROACHEMENTS ON PUBLIC PROPERTY,NOT SPECIFICALLY PERMITTED UNDER THE BUILDING CODE,MUST BE APPROVED BYTHE JURISDICTION. STREET OR ALLY GRADES'AS WELL'AS DEPTH AND LOCATION OF PUBLIC SEWERS MAY 6E`OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS:. THE ISSUANCE OF THIS PERMIT DOES NOT RELEASE THE APPLICANT FROM;THE CONDITIONS OF ANY APPLICABLE SUBDIVISION RESTRICTIONS. MINIMUM OF FOUR CALL INSPECTIONS REQUIRED FOR ALL CONTSTRUCTION WORK: 1.FOUNDATION OR FOOTINGS. 2.ALL FIREPLACES MUST BE INSPECTED AT THE THROAT LEVEL BEFORE FIRST FLUE LINING IS INSTALLED. 3.WIRING&PLUMBING INSPECTIONS TO BE COMPLETED PRIOR TO FRAME INSPECTION. 4.PRIOR TO COVERING STRUCTURAL MEMBERS(READY TO LATH). 5.INSULATION. 6.FINAL INSPECTION BEFORE OCCUPANCY. WHERE APPLICABLE,SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL,PLUMBING AND MECHANICAL INSTALLATIONS. WORK SHALL NOT PROCEED UNTIL THE INSPECTOR HAS APPROVED THE VARIOUS STAGES OF CONSTRUCTION. PERMIT WILL BECOME NULL AND VOID IF CONSTRUCTION WORK IS NOT STARTED WITHIN SIX MONTHS OF DATE THE PERMIT IS ISSUED AS NOTED ABOVE.- PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO GUARANTY FUND(as set forth in MGL c.142A). BUILDING INSPECTION APPROVALS PLUMBING INSPECTION APPROVALS ELECTRICAL INSPECTION APPROVALS a ���4Ilk , 2 2 / l N?0- v,z►G�d 2 3 � P (� �C 1 Heating Inspection Approvals Engineering Dept f>� or— Fire Dept 2 B Health Message Page 1 of 2 Barry, Lois From: Dillen, Elizabeth Sent: Thursday, January 24, 2008 11:16 AM To: Barry, Lois Subject: RE: family apts Thanks Lois. I would like to get some background on the properties, so it's probably easiest for me to swing by and make some copies from the files. 161 Ridgewood Ave is good to go-if you don't mind running them by me and then signing off for now, I think that is easiest until they hire someone permanent and give him/her access. thanks! Bettti DWm Special Projects Coordlriator Growth Managevmnt Departvnepit Town Qf Baraistabte 367 iMatvi.Street, Hdannis NIA Tel 508,862.4683 Fax 508.862,4782 -----Original Message----- From: Barry, Lois Sent: Thursday, January 24, 2008 8:44 AM To: Dillen, Elizabeth Subject: RE: family apts Beth, We now issue family apartment building permits and Certificates of Occupancy as long as the unit is attached. The permit records are in Munis. Older family apartments had ZBA decisions. I have a family apartment database. You might want to ask for read only access. Or just ask me. We have an application for 161 Ridgewood Ave. Shall I sign off? You might want to get sign-off authority again, or have the Amnesty sign off removed from the Munis prerequisites. Or shall I just sign off on these without contacting you? Lois -----Original Message----- From: Dillen, Elizabeth Sent: Wednesday, January 23, 2008 2:57 PM To: Barry, Lois Subject: family apts Hi Lois- We have two accessory apartment applicants that were originally issued family apartment permits. Are copies of family apartment permits available electronically? Beth DiU.en Speciat Projects Coordinator Grovvtk Managevnent Departvnevi.t 1/24/2008 r Amnesty Apartments, Last Name BROWN First Name BARBARA M. ' Map Parcel 328104 _ Property No rl 61-1 Property Street I RIDGEWOOD AVENUE Village HYANNIS IState FA7 Zip 02601 Status Comp. Per. Issued i Decision Date I 111007 Recorded Date 1/17/2008 Application# 200800450 Application Date C of C Total 1 Program Total 1=1 Descripton 1 BEDROOM,2 PEOPLE,CREATE APT ABOVE DETACHED GARAGE Cert of Occupancy Issued: Cert of Compliance Issued Notes PER APP RECEIVED 1/23/08,to PR 1/24/08 t e TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Map Parcel Application# ,�ll�090 0 kS Health Division Conservation Division Permit# Tax Collector Date Issued �5 Treasurer Application Fee Planning Dept. — Permit Feed, tS Date Definitive Plan Approved by Planning Board Ci 0/,,',�;4 5- Historic-OKH Preservation/Hyannis Project Street Address � ! ��D9� l�®� /4ve- Village Hy>a,t)N l S vl�',� . cy, a/ Owner �a?_4,4 aWM 141 lie 0 Address e, Telephone ,_Ds- 6d-- 0/5-7 ;I'fiAr p 5og)3),&-3v34 Whev: ni' rs _L;L�_ p� U Permit Request V O 6 JP:FAAA �t e1J_ ®IV& U.c`l i4�e� �i4,c CscS'-S �� i i 4AJD 1� TY _Pohl t- Square feet: 1st floor:existing proposed AM nd floor:existing proposed r= TbtaM,ew t Zoning District Flood Plain Groundwater Overlay ao Project Valuation Construction Type c.a Cn Lot Size Grandfathered: ❑Yes ®'No If yes, attach supporting docu entation n Dwelling Type: Single Family 2 Two Family ❑ Multi-Family(#units) Age of Existing Structure Historic House: ❑Yes UNo On Old King's Highway: ❑Yes ®'No Basement Type: ❑Full ❑Crawl ❑Walkout N Other A41 F &l Basement Finished Area(sq.ft.) Basement Unfinished Area(sq.ft) Number of Baths: Full:existing new Half:existing new Number of Bedrooms: existing 3 new Total Room Count(not including baths):existing new First Floor Room Count J� Heat Type and Fuel: )fGas ❑Oil ❑Electric ❑Other Central Air: ❑Yes 4 No Fireplaces: Existing &66 New Existing wood/coal stove: ❑Yes J9'No Detached garage:Xexisting ❑new size Pool:❑existing ❑new size Barn:❑existing ❑new size Attached garage:❑existing ❑new size Shed:❑existing ❑new size Other: Zoning Board of Appeals Authorization ❑ Appeal# Recorded❑ Commercial ❑Yes 9 No If yes,site plan review# Current Use Proposed Use BUILDER INFORMATION Name o c,y � Telephone,� Number Address License# Home Improvement Contractor# Worker's Compensation# ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO '�SIGNATURE DATE __�— �c —09 FOR OFFICIAL USE ONLY f I - PERwl r NO. DATE ISSUED MAP/PARCEL NO. ADDRESS VILLAGE 1 r ' OWNER DATE OF INSPECTION: FOUNDATION FRAME INSULATION " FIREPLACE ELECTRICAL: ROUGH - FINAL PLUMBING: ROUGH FINAL r GAS: ROUGH FINAL . K q FINAL BUILDING i. DATE CLOSED OUT ASSOCIATION PLAN.NO. r i r h G3CC�C �M � The Commonwealth of Massachusetts � ,l Department oflndustrial Accidents Office of Investigations . JAN 0 8 2008 + a 600 Washington Street i Boston,MA 02111 GROWTH MANAGEMENT' www.mass.gov/dia Workers' Compensation Insurance Affidavit::Builders/Contractors/Electricians/Plu,mbers Applicant Information Please Print Le 'blv Name(Business/Organization/Individual): . //�1��-�-111� R®04 Address: plc (� i i7q'e 4VJoy City/State/Zip: ��J�i s (eeA 0,-46-01 Phone.#: � -.Dl9i Are you an employer? Check the appropriate box: Type of project(required):. 1.❑ I am a employer with 4. El I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. New construction . 2.❑ I am a'sole proprietor or partner- listed on the attached sheet. 7. Remodeling ship and have no employees These sub-contractors have g• Demolition workingfor me in an capacity. employees and have workers' Y P t3'• 9. ❑Building addition [No workers' comp.insurance , comp. insurance.$ required.] 5. We are a corporation and its 10.El Electrical repairs or additions 3.10 I am a homeowner doing all work officers have exercised then I L❑Plumbing repairs or additions myseL. [No workers' comp. right of exemption per MGL l2.❑ Roof repairs insurance required.]t c. 152, §1(4),and we have no 13.❑ Other employees. [No workers' comp. insurance required.] , *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is..the policy and job site information. Insurance Company Name: Policy#or Self-ins.Lic.#: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure.to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statemerit may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct Signature: �� C�l.� r -%�-(E'��v� Date: Phone#: Official use only, Igo not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers'compensation for their employees. Pursuant to this statute, an employee is defined as"...every person in the service of another under any contract of hire, express or implied,oral or written." An employer is defined as"an individual,partnership,association,corporation or other legal entity,or any two.or more of the foregoing engaged in a joint enterprise,and including the legal representatives of a deceased employer,or the receiver or trustee of an individual,partnership, association or other legal entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein,or the occupant of the dwelling house of another who employs persons to do maintenance,construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152, §25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not producedlacceptable evidence of compliance with the insurance coverage required." Additionally,MGL chapter 152, §25C(7)states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for.the performance of public work until acceptable evidence of cornpliarice with the insurance requirements of this chapter have been presented'to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely,by checking the boxes that apply to your situation and,if , necessary,supply sub-contiactor(s)name(s), address(es)and phone number(s) along with their certificate(s)of insurance. Limited Liability Companies'(LLC)or Limited Liability Partnerships(LLP)with no employees other than the members or partners,are not required to carry workers'compensation insurance. If an LLC or LLP does have employees, a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested,not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy,please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete'and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number. In addition,an applicant that must submit multiple permit/license applications in any given year,need only submit one affidavit indicating current policy information(if necessary)and under"Job Site Address"the applicant should write"all locations in city or town)."A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year.Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e. a dog license or permit to burn leaves etc.)said person is NOT required to complete this affidavit. The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address,telephone-and fax number:. The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 6:00 Washington Street Boston,MA 02111 Tel.#617-727-4900 ext 406 or 1-877-MASSAFE Revised I1-22-06 Fax 4 617-727-7749 www.mass.gov/dia } s E' Town-of Barnstable P�OFTM �~O Regulatory Services * saxr?seneM Thomas F.Geiler,Director y Mass. g . sag9 �m BiuldiIlQ Division plFD MA'S a b Tom Perry,Building Commissioner 200 Main Street, Hyaffiis,MA 02601 Office: 509-862-4038 Fax; 508-790-6230 Permit no. Date AFFIDAVIT HOME IMPROVEMENT CONTRACTOR LAW SUPPLEMENT TO PERMIT APPLICATION MGL c. 142A requires that the"'reconstruction,alterations,renovation,repair,modernization,conversion, •improvement,removal,demolition,or construction of an addition to any pre-existing owner-occupied building containing at least one but not more than four dwelling units or to structures which are adjacent to such residence or building be done by registered contractors,with certain exceptions,along with other requements. Type of Work: Re op Estimated Cost , ` Address of Work: 2 i Eyeio(.flDn i�rtL 7 "IA�i�'r°S � �®C Owner's Name: ��a�,e,� %2Pttid Date of Application: I hereby certify that: Registration is not required for the following reason(s): ❑Work excluded by law ❑Job Under$1,000 QEuildng not owner-occupied NOwner pulling own permit Notice is hereby given that: OWNERS PULLING THEIR OWN PERMIT OR DEALING WITH UNREGISTERED CONTRACTORS FOR APPLICABLE HOME IMPROVEMENT WORK DO NOT HAVE ACCESS TO THE ARBITRATION PROGRAM OR GUARANTY FUND UNDER MGL c.142A. SIGNED UNDER PENALTIES.OF PERJURY I hereby apply for a permit as the agent of the owner: Date Contractor Name Registration No. OR ✓ Date Owner's Name Q:fo=:hcmeaffidav Sa]fClite@ I utoGlass � 36 Ad , - � -- 73 i l �,� t s AAO 1.800.800.ASAP 2722SP I /4p(Ble-i6�(rf i q�U N 1 G. ,J,,, /Q�Gc�d4 Lo ' CE —� t4 ;F. �14 e: At v p� � �OF,THE,p� Town of Barnstable Regulatory Services sAMSTABLE, : Thomas F. Geiler,Director MASS. 039. .�� Building Division.elfD��p i Tom Perry,Building Commissioner 200 Main Street, Hyannis,MA 02601 www.town.barnstable.ma.us Office: 508-862-4038 Fax: 508-790-6230 -------------- -- --------------_ HOMEOWNER LICENSE EXEMPTION Please Print DATE: JOB LOCATION: / /�/!�� tAlpO 6 Ale, 91141,W15 "nuum�ber street village "HOMEOWNER": '/t1MMA '&OW/J 17S1edl !S©8 t62 "01q 7 name home phone# work phone# CURRENT MAILING ADDRESS: 2,o, /3®Ic d ) y;7 city/ wn state zip code The current exemption for"homeowners"was extended to include owner-occupied dwellings of six units or less and to allow homeowners to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor. DEFINITION OF HOMEOWNER Person(s)who owns a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be, a one or two-family dwelling,attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such "homeowner"shall submit to the Building Official on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. (Section 109.1.1) The undersigned"homeowner"assumes responsibility for compliance with the State Building Code and other applicable codes, bylaws,rules and regulations. The undersigned"homeowner"certifies that he/she understands the Town of Barnstable.Building Department. minimum inspection procedures and requirements and that he/she will comply with said procedures and reMuirements. Signature of Homeowner Approval of Building Official Note: Three-family dwellings containing 35,000 cubic feet or larger will be required to comply with the State Building Code Section 127.0 Construction Control. HOMEOWNER'S EXEMPTION The Code states that: "Any homeowner performing work for which a building permit is required shall be exempt from the provisions of this section(Section 109.1.1-Licensing of construction Supervisors);provided that if the homeowner engages a person(s)for hire to do such work,that such Homeowner shall act as supervisor." Many homeowners who use this exemption are unaware that they are assuming the responsibilities of a supervisor(see Appendix Q. Rules&Regulations for Licensing Construction Supervisors,Section 2.IS) This lack of awareness often results in serious problems,particularly when the homeowner hires unlicensed persons. In this case,our Board cannot proceed against the unlicensed person as it would with a licensed Supervisor. The homeowner acting as Supervisor is ultimately responsible, To ensure that the homeowner is fully aware of his/her responsibilities,many communities require,as part of the permit application, that the homeowner certify that he/she understands the responsibilities of a Supervisor. On the last page of this issue is a form currently used by several towns. You may care t amend and adopt such a form/certification for use in your community. Bk 22609 Pa215 ?cgs 1 01-17-2008 a 1 2=34 is yc e BARNSTABL� TDtd'' IKE b 9. '07 00T 11 P 4 :28 Town of Barnstable Zoning Board of Appeals Comprehensive Permit Decision and Notice Appeal 2007-091-Brown . 1 Decision- Chapter 40B Comprehensive Permit Applicant: Barbara M. Brown Property Address: 161 Ridgewood Avenue, Hyannis, MA Assessor's Map/Parcel: Map 328, Parcel 104 Zoning: Residential B Zoning District Applicants: The applicant is Barbara M. Brown,who resides at 161 Ridgewood Avenue, Hyannis, MA. Ms. Brown was granted title to the property by deed recorded in the Barnstable County Registry of Deeds on April 28, 2000 as recorded in Book 4565, Page 019. Relief Requested: The applicant has applied for a Comprehensive Permit under Chapter 40B of the General Laws of the Commonwealth of Massachusetts, and in accordance with Article II of Chapter Nine of the Code of the Town of Barnstable, more commonly termed the"Accessory Affordable Apartment Program." The zoning relief necessary for this Comprehensive Permit to be issued is that of a variance to Section 9- 1 5 of the Code—Amnesty Program to permit an accessory apartment unit adjacent to a single-family owner-occupied residential dwelling. The issuance.of this Comprehensive Permit would allow for an accessory affordable apartment unit above the detached garage. Locus and Background: The property at issue is a 0.33-acre lot located at 161 Ridgewood Avenue in Hyannis. The lot was developed in 1952 with a single-family ranch style home. The effective living area of the main residence is 942 square feet. The proposed accessory apartment is a one-bedroom unit located above the detached garage. The square footage of the rental area is limited to 471 square feet. The lot is served by public water and sewer, and is located within a Wellhead Protection Overlay District. The town of Barnstable's Public Health Division reviewed the application and approved a total of four bedrooms at the property. Procedural Summary: A site approval letter was issued for the property by Town Manager John Klimm on August 24, 2007, in accordance with MGL Chapter 40B and 760 CMR: Notice of the site approval letter was sent to the Department of Housing and Community Development in accordance with the requirements of CMR 760. An application for a Comprehensive Permit was then filed at the Town Clerk's Office and the Office of the Zoning Board of Appeals. H A public hearing before the Zoning Board of Appeals Hearing Officer was duly advertised in the Barnstable Patriot on August 31, 2007 and-September 7, 2007, and notices were sent to all abutters in accordance with MGL Chapter 40B. On September 26, 2007 Hearing Officer Gail Nightingale presided over the public hearing. The applicant, Barbara Brown, was present at the hearing. Madeline Taylor of the Growth Management Department was also present. Ms.Nightingale reviewed the file with the applicant to ensure compliance with all of the program requirements. Findings of Fact on the Comprehensive Permit: At the hearing on September 26, 2007 the Hearing Officer made the following findings of fact: . 1. The applicant is Barbara Brown who resides at 161 Ridgewood Avenue, Hyannis, MA. She is requesting a Comprehensive Pen-nit to create a one-bedroom accessory affordable apartment above the detached garage. The creation of the unit within a single-family owner-occupied residential dwelling qualifies for the "Accessory Affordable Apartment Program." 2. Barbara Brown was granted title to the property by deed recorded in the Barnstable County Registry of Deeds on April 28, 2000 as recorded in Book 12974, Page 246. 3. On August 7, 2007 a site approval letter was issued for the property by Town Manager John Klimm, in accordance with MGL Chapter 40B and 760 CMR. Notice of the site approval letter was sent to the Department of Housing and Community Development, in accordance with the requirements of CMR 760, and no issues were communicated from the Department on this particular application. 4. The proposed accessory affordable unit is limited to 471 square feet square feet, and is located above the detached garage. I 5. The applicant is aware that the unit must meet all applicable building codes to be occupied and that the Building Division and Fire Department will also be inspecting the unit for compliance with all applicable building and fire codes. 6. The house is served by public water and sewer and is in an identified Wellhead Protection Overlay District. The proposal has been reviewed by Thomas McKean, Health Director, and he has approved a total of four(4)bedrooms at the property. 7. On April 17, 2007 the applicant signed an Accessory Affordable Apartment Program Agreement Affidavit that commits, upon the receipt of a Comprehensive Permit,to the recording of a Regulatory Agreement and Declaration of Restrictive Covenants at the Barnstable Registry of Deeds. That document will restrict the unit in perpetuity as an affordable rental unit and requires that the dwelling be owner-occupied as her principal residence. 8. The applicant understands that the affordable unit will be rented to a person or family whose income is 80% or less of the Area Median Income(AMI) of the Barnstable Metropolitan Statistical Area(MSA)and further agrees that rent(including utilities) shall not exceed 30% of the monthly household income of a household earning 80% of the median income, adjusted by household size. In the event that utilities are separately metered, the utility allowance established by the town of Barnstable shall be deducted from rent level so calculated. 9. According to the Massachusetts Department of Housing and Community Development, as of September 26, 2007 6.63%of the town's year round housing stock qualifies as affordable housing units. The town has not reached the statutory minimum of affordable housing under MGL Chapter 40B Section 20-23 or its implementing regulations. The Town of Barnstable's Local Comprehensive Plan encourages the use of existing housing to create affordable units and the dispersal of these units throughout the town. 2 s Finding Summary: Based upon the findings, the Hearing Officer ruled that the applicant has standing to apply for a Comprehensive Permit under MGL Chapter 40B and the Town of Barnstable's Accessory Apartment Program. The proposal is also deemed consistent with local needs because it adequately promotes the objective of providing affordable housing for the town of Barnstable without jeopardizing the health and safety of the occupants provided all conditions of the Comprehensive Permit are strictly followed. Ruling and Conditions: Based upon the findings, a ruling was made to grant the Comprehensive Permit in accordance with MGL Chapter 4013 to the applicant,Barbara Brown. It is issued to allow for a one-bedroom accessory affordable apartment unit in accordance with the following conditions:. 1. Occupancy of the affordable unit shall not exceed two persons. 21 The total number_of bedrooms on the property shall not exceed three(3).` k4l 3. The property owner shall occupy the principal dwelling as her principal residence. 4. This unit shall not be occupied by a family member of the owner(s). 5. All parking for the accessory apartment and the main dwelling shall be on-site and no lodging shall be permitted for the duration of the comprehensive permit. 6. To meet the requirements of affordability, the cost of housing(including utilities) shall not exceed 30% of 80% of the median income for a single individual for the Barnstable MSA. In the event that utilities are separately metered, the utility allowance established by the town of Barnstable shall be deducted from rent level so calculated: 7. All leases shall have a minimum term of one year. 8. The Growth Management Department shall serve as the monitoring agent for the accessory apartment. 9. The applicant.must apply for a building permit for the accessory unit,whether the unit is new or pre-existing. Before securing an occupancy permit and certificate of compliance,the Building Commissioner must determine that the unit conforms with the approved plans as submitted with the building permit application and meets state building and fire codes. The Health Division must determine that the dwelling is in compliance with applicable on-site wastewater discharge requirements. 10. The applicant may select her own tenant provided the tenant meets the requirements of the program as cited above and provided that person's income is reviewed and approved by the Growth Management Department of the town of Barnstable as a qualified individual. The applicant will be required to work with the town to provide information necessary to document that the tenant qualifies. The unit shall be rented on an open and fair basis to an income eligible individual or family. Whenever a vacancy occurs, notice must be given to the Growth Management Department and the unit must be listed with the Town. 11. Every twelve months the applicant shall review the income eligibility of the individual occupying the unit. No later than a year from the date of issuance of this Comprehensive Permit,the applicant shall file with the Growth Management Department of the town of Barnstable an annual affidavit listing the rent charged and income level of the occupant of the unit. The applicant shall provide the town any additional information it deems necessary to verify the information provided in the affidavit. Upon any report from the town that the terms and conditions of this permit are not being upheld, the Zoning Board of.Appeals or it's Hearing Officer shall have the ability to hold a hearing to show cause as to why this permit should not be revoked. 3 12. This Comprehensive Permit shall not be transferable to any other person or entity without the prior approval of the Hearing Officer or Zoning Board of Appeals. This decision,the Regulatory Agreement and Declaration of Restrictive Covenants and all other necessary documents shall be filed at the Barnstable County Registry of Deeds. If the ownership of the property is transferred,the Growth Management Department of the town of Barnstable shall be notified within 60 days of the name and address of the new owner. 13. This Comprehensive Permit must be exercised and the unit occupied within 12 months of its issuance or it shall expire. Ordered: Comprehensive Permit 2007-091 has been granted with conditions. A written copy of this decision shall be forwarded to the Zoning Board of Appeal as required by the Town of Barnstable Administrative Code Chapter 241, section 11. If after fourteen (14)days from that transmittal the Members of the Zoning Board of Appeals takes no action to reverse the decision, this decision shall become final and a copy shall be the filed in the office of the Town Clerk. Appeals of the final decision, if any, shall be made to the Barnstable Superior Court pursuant to MGL Chapter 40A, Section 17,within twenty(20) days after the date of the filing of this decision in the office of the Town Clerk. The applicant has the right to appeal this decision as outlined in MGL Chapter 40B, Section 22. In accordance with Chapter 241, section 11 of the Town of Barnstable Administrative Code,the hearing officer transmitted a written copy of the Comprehensive Permit decision to the Zoning Board of Appeals on September 26, 2007. Fourteen (14)days have elapsed since the transmittal to the Board, and no Board Member has taken action to reverse the decision. At 011 p G Nightingale, Jaring Of er Date Signed 1, Linda Hutchenrider, Clerk of the Town of Barnstable, Barnstable County, Massacl-iusetts,.hereby certify that twenty(20)days have elapsed since the Zoning Board of Appeals filed this decision and.that no appeal of the decision has been filed in the office of the Town Clerk. Signed and sealed this i day ofa �'� der the pains.and penalties of perjury. c Linda Hutchenrider, Town Clerk 4 i Barnstable The Town of Barnstable * '" MASS. Growth Management Department A114mericaCfty 9 � � g P �Ar 1639. p 367 Main Street,Hyannis,MA 02601 D Office: 508-862-4678 Patty Daley Fax: 508-862-4782 Interim Director 2007 To: Linda Hutchenreider, Town Clerk From: Patty Daley, Growth Management, Interim Director Date: February 5, 2008 Re: ZBA Decision Appeal 2007-091-Brown This dec' ' contains a scrivener's error. Under the section Rulings and Conditions, page , # 3 s ould read: The total number of bedrooms on the property shall not exceed four(4). 01--17-2008 a 12Q34pk REGULATORY AGREEMENT AND DECLARATION OF RESTRICTIVE COVENANTS THIS REGULATORY AGREEMENT and DECLARATION OF RESTRICTIVE COVENANTS,is made this day of ,2008,by and between Barbara M. Brown aka Barbara M. Haskell of 161 Ridgewood Avenue,Hy nnis,MA and its successors and assigns (hereinafter the "Owner"),and the TOWN OF BARNSTABLE (the "Municipality'),a political subdivision of the Commonwealth; WHEREAS the Owner has been granted a Comprehensive Permit under Massachusetts General Law Chapter 40B and local regulations by the Zoning Board of Appeals to permit the creation of an accessory apartment in an owner occupied dwelling which will be rented to a Low or Moderate Income Person/Family(hereinafter "Designated Affordable Unit");and NOW THEREFORE,in mutual consideration of the agreements and covenants contained herein, and other good and valuable consideration,the receipt and sufficiency of which is hereby acknowledged,the parties agree , as follows: I. PROJECT SCOPE AND DESIGN: A. The terms of this Agreement and Covenant regulate the property located at 161 Ridgewood Avenue, Hyannis, MA as further described in deed recorded herewith as Barnstable County Registry of Deeds Book 4565,Page 019. B. The Project located at 161 Ridgewood Avenue,Hyannis,MA will consist of one accessory apartment unit v�hich will be rented to an eligible low or moderate income individual or family(the "Designated Affordable Unit" or the "Unit"). C. The Owner agrees to construct the Project in accordance with the terms of comprehensive permit Appeal No. 2007-091 and any plans submitted therewith and all applicable state, federal and municipal laws and regulations. Said permit is recorded herewith as Barnstable County Registry of Deeds Book 22(POOI Page 21S D. The Owner agrees to occupy the principal dwelling unit located on the property as their principal residence in accordance with the terms of the comprehensive permit. II. TF E OWNER'S COVENANTS AND RESPONSIBILITIES: A. THE OWNER HEREBY REPRESENTS,COVENANTS AND WARRANTS AS FOLLOWS: 1 In receiving the comprehensive permit to create the Designated Affordable unit,the Owner agreed that the Designated Affordable Unit shall be set aside in perpetuity for the public purpose of providing safe and decent housing to persons earning at or below 80% of the area median income of Barnstable Metropolitan Statistical Area (MSA) and that the Designated Affordable Unit shall be deemed to be impressed with a public trust. 2. The Designated Affordable Unit shall be rented in perpetuity to a household with a maximum income of 80% of the Area Median Income (AMI) of Barnstable MSA and that rent (including utilities) shall not exceed an amount that is affordable to a household whose income is 80% of the median income of Barnstable MSA. In the event that utilities are separately metered,a utility allowance established by the Barnstable Housing Authority shall be deducted from the rent level. 3. The Designated Affordable Unit will be retained as a permanent,year round rental dwelling unit with at least a one-year lease. 4. The Owner has the full legal right,power and authority to execute and deliver this Agreement. 5. The execution and performance of this Agreement by the Owner will not violate or,as applicable,has not violated any provision of law,rule or regulation,or any order of any court or other agency or governmental n " body,and will not violate or,as applicable,has not violated.any provision of any indenture,agreement,mortgage, mortgage note,or other instrument to which the Owner is a parry or by which it or the Owner is bound,will not result in the creation or imposition of any prohibited encumbrance of any nature. 6. The Owner,at the time of execution and delivery of this Agreement,has good,clear marketable title to the premises. 7. There is no action,suit or proceeding at law or in equity or by or before any governmental instrumentality or other agency now pending,or,to the knowledge of the Owner,threatened against or affecting it, or any of its properties or rights,which,if adversely determined,would materially impair its right to carry on business substantially as now conducted(and as now contemplated by this Agreement) or would materially adversely affect its financial condition. B. COMPLIANCE The Owner hereby agrees that any and all requirements of the laws of the Commonwealth of Massachusetts to be satisfied in order for the provisions of this Agreement to constitute restrictions and covenants running with the land shall be deemed to be satisfied in full and that any requirements of privileges of estate are also deemed to be satisfied in full. C. LIMITATION ON PROFITS 1. The Owner agrees to limit his/her profit by renting the Designated Affordable Unit in perpetuity to a household with a maximum income of 80% or less of the Area.Median Income (AMI) of Barnstable Metropolitan Statistical Area (MSA) and that rent(including utilities) shall not exceed an amount that is affordable to a household whose income is 80% of the median income of Barnstable MSA. In the event that utilities are separately metered,a utility allowance established by the Barnstable Housing Authority shall be deducted from the rent. 2. The Owner shall annually deliver to the Municipality and to the Monitoring Agent,as designated by the Town Manager,proof that the Designated Affordable Unit is rented,the tenant's income verification,a copy of the lease agreement and the rent charged for the unit or units. Such information shall also be forwarded to the Monitoring Agent within 30 days of the occupation of the dwelling unit or units by a new tenant. The Owner shall notify the Monitoring Agent, as designated by the Town Manager,within thirty(30) days of the date that a tenant has vacated the Designated Affordable Unit. III. MUNICIPALITY COVENANTS AND RESPONSIBILITIES 1. The MUNICIPALITY,through the monitoring agent designated by the Town Manager agrees to perform the duties of verifying that the Designated Affordable Unit is being rented in perpetuity to a household with a maximum income of 80% or less of the Area Median Income (AMI) of Barnstable MSA and that rent (including utilities) shall not exceed an amount that is affordable to a household whose income is 80% of the median income of Barnstable MSA.In the event that utilities are separately metered,a utility allowance established by the Barnstable Housing Authority shall be deducted from the rent. IV. RECORDING OF AGREEMENT: Upon execution,the OWNER shall immediately cause this Agreement and any amendments hereto to be recorded with the Registry of Deeds for Barnstable County or,if the Project consists in whole or in part of registered land,file this Agreement and any amendments hereto with the Registry District of the Barnstable Land Court (collectively hereinafter the "Registry of Deeds"),and the Owner shall pay all fees and charges incurred in connection therewith. Upon recording or filling,as applicable,the Owner shall immediately transmit to the Municipality evidence of such recording or filing including the date and instrument, book and page or registration number of the Agreement. 2 V. GOVERNING OF AGREEMENT: This Agreement shall be governed by the laws of the Commonwealth of Massachusetts. Any amendments to this Agreement must be in writing and executed by all of the parties hereto. The invalidity of any clause,part or provision of this Agreement shall not affect the validity of the remaining portions hereof. VI. NOTICE: All notices to be given pursuant to this Agreement shall be in writing and shall be deemed given when delivered by hand or when mailed by certified or registered mail,postage prepaid,return receipt requested,to the parties hereto at the addresses set forth below,or to such other place as a parry may from time to time designate by written notice. VII. HOLD HARMLESS: The Owner hereby agrees to indemnify and hold harmless the Municipality and/or its delegate from any and all actions or inactions by the Owner,its agents,servants or employees which result in claims made against Municipality and/or its delegate,including but not limited to awards,judgments,out-of-pocket expenses and attorneys fees necessitated by such actions. VIII. ENTIRE UNDERSTANDING: A. This Agreement shall constitute the entire understanding between the parties and any amendments or changes hereto must be in writing,executed by the parties,and appended to this document. B. This Agreement and all of the covenants, agreements and restrictions contained herein shall be deemed to be for the public purpose of providing safe affordable housing and shall be deemed to be, and by these presents are, granted by the Owner to run in perpetuity in favor of and be held by the Municipality as any other permanent restriction held by a governmental body as that term is used in MGL Ch..184, Section 26 which shall run with the land described in deed recorded herewith as Barnstable County Registry of Deeds Book 4565, Page 019 and shall be binding upon the Owner and all successors in title . This Agreement is made for the benefit of the Municipality and the Municipality shall be deemed to be the holder of the restriction created by this Agreement. The Municipality has determined that the acquiring of such a restriction is in the public interest. The Municipality shall not be subject to the defense of lack of privity of estate. The covenants and restrictions contained in this Agreement shall be deemed to affect the title to the property described in deed recorded herewith as Barnstable County Registry of Deeds Book 4565,Page 019. IX. TERM OF AGREEMENT: The term of this Agreement shall be perpetual,provided,however,that the Owner of,a Designated Affordable Unit or Units may voluntarily cancel the granted Comprehensive Permit and the terms and restrictions imposed herein. Such cancellation shall only take effect after: 1) expiration of the lease terms entered into between the Owner and Tenant occupying said unit and 2) notification by the Owner of said dwelling to the Zoning Board of Appeals of his/her desire to cancel the Comprehensive permit upon a date certain and the recording of said notice at the Barnstable County Registry of Deeds or Barnstable County Registry of the Land Court as the case maybe,thus rendering said Comprehensive Permit void. Upon the cancellation of the comprehensive permit,the property which is the subject matter of this restrictive covenant shall revert to the use permitted under zoning and the restrictive covenant shall be rendered void. 3 I X. 'SUCCESSORS AND ASSIGNS: A. The Parties to this Agreement intend,declare,and covenant on behalf of themselves and any successors and assigns their rights and duties as defined,in this Regulatory Agreement and the attached comprehensive permit. B. The Owner intends, declares,and covenants on behalf of itself and its successors and assigns (i) that this Agreement and the covenants,agreements and restrictions contained herein shall be and are covenants running with the land,encumbering the Project for the term of this Agreement,and are binding upon the Owner's successors in title, (ii) are not merely personal covenants of the Owner,and (iii) shall bind the Owner,its successors and assigns and inure to the benefit of the Municipality and its successors and assigns for the term of the Agreement. XI. DEFAULT: If any default,violation or breach by the Owner of this Agreement is not cured to the satisfaction of the Monitoring Agent within thirty(30) days after notice to the Owner thereof,then the Monitoring Agent may send notification to the Municipality that the Owner is in violation of the terms and conditions hereof. The Municipality may exercise any remedy available to it. The Owner will pay all costs and expenses,including legal fees,incurred by the Monitoring Agent in enforcing this Agreement and the Owner hereby agrees that the Municipality and the Monitoring Agent will have alien on the Project to secure payment of such costs and expenses. The Monitoring Agent may perfect such alien on the Project by recording a certificate setting forth the amount of the costs and expense due and owing in the Registry of Deeds or the Registry of the District Land Court for Barnstable County. A purchaser of the Project or any portion thereof will be liable for the payment of any unpaid costs and expenses that were the subject of a perfected lien prior to the purchaser's acquisition of the Project or portion thereof. MI. MORTGAGEE CONSENT: The Owner represents and warrants that it has obtained the consent of all existing mortgagees of the Project to the execution and recording of this Agreement and to the terms and conditions hereof and that all such mortgagees have executed consent to this Agreement. IN WITNESS WHEREOF,we hereunto set our hands and seals thisjZday of Ka,Q 2008. OWNER BY: Sgnature Printed:Barbara M.Brown aka Barbara M.Haskell COMMONWEALTH OF MASSACHUSEM County of Barnstable,ss: On this?R d day o n 2008 before me,the undersigned notary public,personally appeared IL CRI?q A tt ,the Owner(s),proved to me through satisfactory evidence of identification,which were 1),06 v�� c .��'���,c —( u s s, ,to be the person(s)whose name(s) is signed on the preceding or attached document and acknowledged to be that he/she signed it voluntarily for the stated purposes. Notary Public INPUMC Printed: x I 4 TOWN OF B STABLE BY: 77 TOW MANAGER COMMONWEALTH OF MASSAC HUSETTS County of Barnstable,ss: On this o' ltdayof�,-nthe 2008 before me,the undersigned notary public,personally appeared J 6h n (� 4 Kit rown Manager for the Town of Barnstable,proved to me through satisfactory evidence of identification which were L"�'h_(o-( UZ,�.�--- � ,to be the person whose name is signed on the preceding or attached document and ac owledg'd to be signed it voluntarily for the stated purposes. No ry Public Printed: �!'1//�/��~`� �� My Commission Expires: !C—\- OFFtC1A1.�' . -= SNIRLNoE0 C 3 __ _ ' coeluoNv�a�n+OFM�'�g12oo� idly Comm.EXPO 5 tNE TOWN OF BARNSTABLEBuilding' l�y Application Ref: 20060703 • BARNSTABLE, * Issue Date: 06/23/06 Permit y MASS, �ArEO A�� Applicant: BERT DEMARTIN Permit Number: B 20060519 Proposed Use: RESIDENTIAL Expiration Date: 12/21/06 Location 161 RIDGEWOOD AVENUE Zoning District SF Permit Type: GARAGE DETACHED RESIDENTIAL Map Parcel 328104 Permit Fee$ 164.00 Contractor BERT DEMARTIN Village HYANNIS App Fee$ 100.00 License Num 040711 Est Construction Cost$ 40,000 Remarks APPROVED PLANS MUST BE RETAINED ON JOB AND DETACHED GARAGE WITH 2ND FLOOR-STORAGE WITH BATHRO MTHIS CARD MUST BE KEPT POSTED UNTIL FINAL INSPECTION HAS BEEN MADE. WHERE A CERTIFICATE OF OCCUPANCY IS REQUIRED,SUCH Owner on Record: BROWN, BARBARA M BUILDING SHALL NOT BE OCCUPIED UNTIL A FINAL Address: P O BOX 2247 INSPECTION HAS BEEN E. HYANNIS, MA 02601 Application Entered by: DB Building Permit Issued By: THIS PERMIT CONVEYS,N&AIGHT TO OCCUPY ANY STREET ALLY OR SIDEWALK OR ANY PART THEREOF,EITHER TEMPORARILY OR P NENTLY ENCROACHEMENTSONPUBUC PROPERTY:NOT SPECIFICALLY PERMITTED UNDER THE BT1IlDING CODE MUST BE APPROVED BY THE JURISDICTION' STREET OR ALLY'GRADES AS WELL AS DEPTH AND,LOCATION OF PUBLIC SEWERS M'AY BE OBTAINED FROM=THE DEPARTMENT OF",PUBLIC-WORKS THE ISSUANCE OF.THIS PERMIT DOES NOT•RELEASE` n THE APPLICANT FROM THE CONDITIONS OF ANY APPLICABLE SUBDIVISION,RESTRICTIC?NS MINIMUM OF FOUR CALL INSPECTIONS REQUIRED FOR ALL CONTSTRUCTION WORK: 1.FOUNDATION OR FOOTINGS. 2.ALL FIREPLACES MUST BE INSPECTED AT THE THROAT LEVEL BEFORE FIRST FLUE LINING IS INSTALLED. 3.WIRING&PLUMBING INSPECTIONS TO BE COMPLETED PRIOR TO FRAME INSPECTION. 4.PRIOR TO COVERING STRUCTURAL MEMBERS(READY TO LATH). 5.INSULATION. 6.FINAL INSPECTION BEFORE OCCUPANCY. WHERE APPLICABLE,SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL,PLUMBING AND MECHANICAL INSTALLATIONS. WORK SHALL NOT PROCEED UNTIL THE INSPECTOR HAS APPROVED THE VARIOUS STAGES OF CONSTRUCTION. PERMIT WILL BECOME NULL AND VOID IF CONSTRUCTION WORK IS NOT STARTED WITHIN SIX MONTHS OF DATE THE PERMIT IS ISSUED AS NOTED ABOVE. PERSONS CONTRACTING WITH UNREGISTERED CONTRAC TORS DO NOT HAVE ACCESS TO GUARANTY FUND(as set forth in MGL c.I42A). BUILDING INSPECTION APPROVALS PLUMBING INSPECTION APPROVALS ELECTRICAL INSPECTION APPROVALS 1 1 1 2 2 2 3 1 Heating Inspection Approvals Engineering Dept Fire Dept 2 Board of Health r MAP PAR, C(� P MASSACHUSETTS UNIFORM APPLICA ON-FOR PERMIT TO DO PLUMBING .(Print or Type) Barnstable , Mass. Date 0 Permit Building Location \ Owner's Name �15vGG� A: 1 L : Type of Occupancy Ne ge Renovation ❑ Replacement ❑ Plans Submitted: Yes ❑ No ❑ FIXTURES Y z z I }-- .-� � 0 Z 0 cc ca tuw LU OtcnF�- wM � C Code 0z °- � - co W G7 = = H V dCZ CC -C O ¢ roocCCwa � odr0ZCa = O CC = CF- ZDzt CC 00 = � co0C � d2cccLLLLa = '' -, Ya0 ccZCC cW cc�... Imo- a0 � dOd � Qdoc ¢ cc 0cc I ,� �e � ont000c X: ou_ t� � � d � ecm0 .. \ SUB-BSMT. w BASEMENT u 1 ST FLOOR •' 2ND FLOOR 3R0 FLOOR 4TH FLOOR 5TH FLOOR 6TH FLOOR 7TH FLOOR 8TH FLOOR Check one: Certificate w. Installing Company Name u Corporation Address Oo� _ti'L El Partnership t 1 Business Telephone — Name of Licensed Plumber INSURANCE COVERAGE: I have a curren i ity policy or its substantial equivalent which meets the requirements of MGL Ch. 142. Yes 0 No ❑ If you have checked yes, please indicate the type coverage by checking the appropriate box. A liability insurance policy � Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have'the insurance coverage required by Chapter 142 of the Mass. General Laws, and that my signature on this permit application waives this requirement. Check one: Signature of Owner or Owner's Agent Owner ❑ Agent ❑ I hereby certify that all of the details and information I have submitted (or entered) in above application are true and accurate to the best of my knowledge and that all plumbing work and Installations performed under the permit issued for this application will be in compliance with all pertinent provisions of the Massachusetts State Plumbing Code and C ter 1 of the General Laws. By Title i re of Licensed ber City/Town ype of License: Master Journeyman ❑ AP P ROVED (OFFICE USE ONLY) License Number Message Page 1 of 1 Roma, Paul From: Taylor, Madeline Sent: Tuesday, October 10, 2006 1:27 PM To: Perry, Tom; Roma, Paul Subject: 161 Ridgewood Avenue Hi The owners of the above properly have contacted me regarding creating an accessory affordable apartment above the garage. They mentioned that there had been some issues with the Building Division. I have an appointment tomorrow to go look at the proposed apartment. Should I be aware of anything before I go out there? Thanks Madeline /0 Madeline Taylor j�q_p44A. - Accessory Affordable Apartment Program Coordinator Growth Management Department i Town of Barnstable 367 Main Street Hyannis,MA 02601 Phone:508-862-4743 Fax: 508-862-4782 / 9- 11 l 10/11/2006 KeyBean®4.410h 7-18-06 kmBeamEngine 4.413r Maten als Database 516 7:44am Q&A ' 6(ef) 0. e. 1 of 2 Member Data Description: Member Type: Girder Application: Floor Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: SBC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 38.0 PLF DOL: .100°>$ F.ilenams:.KY-61 Non-standard Loads Type Trib. Live Dead {DescApt" -Begin End Width -start -End -Start -End DOL Replacement Uniform (PLF) 0' 0.001, 26' 0.00" 210 407 100% Additional Uniform PLF 0' 0.00" 26' 0.00" 631 0 100% ti. 2600 2600 L�rodu'e� 'Da-t"a D Wweb Sx Fy Fy' Fy' ' , Ix Lc Lu ft ft in3 psi psi psi in4 ft ft 14.10 0.310 54.60 50000 0 31900 385.00 11.5 7.1 -Compact Section d/Af EI K Live Total 1/in LBS.in2 4.040 11165.Ox10^6 0.000 L/360 L/240 Load Case Dead Load Fb =0.66psi * Fy Ma = 19078'# Va = 21884# Segment(ft) 1(ft) Fb(psi) Ma('#)' 0.00 - 26.1$ 0„00 0.66Fy 19078 Load Case Total Load Fb =0.66psi * Fy Ma = 19078'# Va = 21884# Segment(ft) l(ft) Fb(psi) Ma('#)' 0.00 - 26.15 0.00 0.66Fy 19078 -Bearings and Reactions Input Minimum Worst Case Location Type Length Length Total._ 100%d Dead Total 1 0'0.00" Wall N/A N/A 16812# 10995# 5818# 168129 2 26'1.75" Wall N/A N/A 16812# 10995# 5818# 16812# Design spans 26'1.75" Al product names are trademarks of that respective owners David McLean Falmouth Lumber 670Teatidca Highway I Copyright(C)1888-2005 by Keymark EriergSes,LLC.ALL RIGHTS RESER%ED. East Falmouth,MA 0290 ey - Passingis definedas when the member,floor gist,he ar_gVder,shown an this rawng meets appicable design criteria for Loads,Loa]ing Conditions,and Spans 'sted on this sheet.The design must be reviewed by a qualified designer or design ssionaias-required-for approval This designessumes product inctatatim ccord'ng to the manufacturers specifications. - ' 6 KeyBeam(&4.41Oh 7-18-06 1cmBea Engine4.413r Materials Database 516 7:44am 2of2 Product:W 14 x 38(50ksi) Component Member Design has Passed Design Checks.— Design assumes continuous lateral bracing. Allowable Stress Design Actual A116wa61e Capacity Loci 06n UAdfng Positive Moment 109.89'k# 150.15'k# 73% 13.07' Total load 100% Shear 16.81 k# 87.42k# 19% 26.15' Total load 100% LL Deflection 0,7920" 0.8715" U396 13.07' Total load 100% TL Defteclion 1.21IV 13307Y t1259 13:071 Total load 400010 LL DefI.,Lt. N/A TL DefI.,Lt. N/A LL DefI., Rt. N/A TL-f)eFt:,Rt. -N/A Control: TL Deflection AI pmduct names are trademarks ofthsr respective owners David McLean Falmouth Lumber 670Teaticket Highway / Cop"M(C)ISW20%byife7mia*.£rlerl3ses,iiC.6At RnffM RESERWD. East Fah tout h,MA02!B6 Yassngisdefirhed as when the member,Aoa.jaK bean or girder,shown on this cawing meets applicable des gn criers for Loads,loading Conditions,and Spans 'sled on this sheet.The design must be reviewed by a qualged desgner or design rofessonal as required for appmvaL-This design assumes product instalatien ocording to the manufacturer s s fecfoatbns. s F 22/06/2006 8:16 am ri r- t L' I j /Z >nOG 8:17 am -22/06/20@6,8:17am y;il! y e- i qI. 7 F; 22/06/2006 8 am I TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION z Map 3)tl a'l Parcel "t Pd Application# ,� ( Z/'f� Health Division Conservation Division Permit# Tax Collector Date Issued Treasurer Application Fee %O C9 Planning Dept. Permit Fee Date Definitive Plan Approved by Planning Board Historic-OKH Preservation/Hyannis Project Street Address /� eR i d y e woo c, Village T��9/�N��S _ 04 01601 Owner 7,�ry 3^e,4 `73a&jA) Address / f P/4e c.)aa a d ch t�9s��•s Telephone J` Ogg 96,;A" ®/97 Permit Request 6,444!%e, -- P-e MAP--D � o4ay 1A (� ��,�.` s s ,►�/J�j Square feet: 1 st floor:existing proposed �lp Ld floor:existing proposed Total new Zoning District Flood Plain Groundwater Overlay Project Valuation O®Da-00 Construction Type Lot Size Grandfathered: ❑Yes k<o If yes, attach supporting6documentation. R Dwelling Type: Single Family ❑ Two Family ❑ Multi-Family(#units) Age of Existing Structure Historic House: ❑Yes WINo On Old King's Highway: ❑Yes C�No Basement Type: ❑Full ❑Crawl ❑Walkout 21 Other S I A6 Basement Finished Area(sq.ft.) Basement Unfinished Area(sq.ft) Number of Baths: Full:existing new Half:existing new Number of Bedrooms: existing new Total Room Count(not including baths):existing new First Floor Room Count Heat Type and Fuel: ❑Gas ❑Oil ❑Electric ❑Other Central Air: ❑Yes ❑No Fireplaces: Existing New Existing wood/coal stove: ❑Yes ❑No Detached garage:❑existing &(n"ew size Pool:❑existing ❑new size Barn:❑existing ❑new size Attached garage:❑existing ❑new size Shed:❑existing ❑new size Other: Zoning Board of Appeals Authorization ❑ Appeal# Recorded❑ Commercial ❑Yes 2 No If yes,site plan review# Current Use Proposed Use CQe S d�1o'ox 0 � 1 am {, BUILDER INFORMATION '7— O 6 7r V4 e,2rQ� f _ �? � Name PjPr2 �Q c,l�►.' Telephone Number ��o� (�[�a1 Address ,i uok y-c�i ( � � License# �o�� �{-b '��� --- H�mI. o-t s) 'Qt c@fob ( Home Improvement Contractor# Worker's Compensation# ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO SIGNATURE DATE 6-Z/ I_ FOR OFFICIAL USE ONLY ,- PERMIT-NO. DATE ISSUED MAP/PARCEL NO. J ADDRESS r . VILLAGE OWNER DATE OF INSPECTION: ' FOUNDATION FRAME O L p RIP- , E INSULATION FIREPLACE ELECTRICAL: ROUGH FINAL " t PLUMBING: ROUGH FINAL +' GAS: ROUGH FINAL FINAL BUILDING r • DATE CLOSED OUT ASSOCIATION PLAN NO. { o -7 ' t I 1 r JJune 2006 , Town of Barnstable l T. Perry ` Building Division I' Bear Mr. Perry, This letter is to indicate that the 2 car garage to be built at 161 Ridgewood Avenue in Hyannis will have storage space above. I will exercise my rights to go to the Zoning Board of Appeals to convert the storage space into a bedroom with a bath. Sincerely, Barbara Brown MUM a pan Notary Pine rjo7cowweamofm l r 01-17-2008 & 1`=3 4rr-b BARNSTABLE TOVC"Vt�. �tKME rq M""b 4 eg '07 GOT 11 r 4 •2 8 ease Town .of Barnstable Zoning Board of Appeals Comprehensive Permit Decision and Notice Appeal 2007-091-Brown Decision - Chapter 40B Comprehensive Permit Applicant: Barbara M. Brown Property Address: 161 Ridgewood Avenue, Hyannis, MA Assessor's Map/Parcel: Map 328, Parcel 104 Zoning: Residential B Zoning District Applicants; The applicant is Barbara M. Brown, who resides at 161 Ridgewood Avenue, Hyannis, MA. Ms. Brown was granted title to the property by deed recorded in the Barnstable County Registry of Deeds on April 28, 2000 as recorded in Book 4565, Page 019. Relief Requested:' The applicant has applied for a Comprehensive Permit under Chapter 40B of the General Laws of the Commonwealth of Massachusetts, and in accordance with Article II of Chapter Nine of the Code of the Town of Barnstable, more commonly termed the "Accessory Affordable Apartment Program." The zoning relief necessary for this Comprehensive Permit to be issued is that of a variance to Section 9- 15 of the Code—Amnesty Program to pen-nit an accessory apartment unit adjacent to a single-family owner-occupied residential dwelling. The issuance of this Comprehensive Permit would allow for an accessory affordable apartment unit above the detached garage. Locus and Background: The property at issue is a 0.33-acre lot located at 161 Ridgewood Avenue in Hyannis. The lot was developed in 1952 with a single-family ranch style home. The effective living area of the main residence is 942 square feet. The proposed accessory apartment is a one-bedroom unit located above the detached garage. The square footage of the rental area is limited to 471 square feet. The lot is served by public water and sewer, and is located within a Wellhead Protection Overlay District. The town of Barnstable's Public Health Division reviewed the application and approved a total of four bedrooms at the property. Procedural Summary: A site approval letter was issued for the property by Town Manager John Klimm on August 24, 2007, in accordance with MGL Chapter 40B and 760 CMR. Notice of the site approval letter was sent to the Department of Housing and Community Development in accordance with the requirements of CMR 160. An application for a Comprehensive Permit was then filed at the Town Clerk's Office and the Office of the Zoning Board of Appeals. A public hearing before the Zoning Board of Appeals Hearing Officer was duly advertised in the Barnstable Patriot on August 31, 2007 and-September 7, 2007, and notices were sent to all abutters in accordance with MGL Chapter 40B. On September 26, 2007 Hearing Officer Gail Nightingale presided over the public hearing. The applicant,Barbara Brown, was present at the hearing. Madeline Taylor of the Growth Management Department was also present. Ms.Nightingale reviewed the file with the applicant to ensure compliance with all of the program requirements. Findings of Fact on the Comprehensive Permit: At the hearing on September 26, 2007 the Hearing Officer made the following findings of fact: 1. The applicant is Barbara Brown who resides at 161 Ridgewood Avenue, Hyannis, MA. She is requesting a Comprehensive Permit to create a one-bedroom accessory affordable apartment above the detached garage. The creation of the unit within a single-family owner-occupied residential dwelling qualifies for the "Accessory Affordable Apartment Program." 2. Barbara Brown was granted title to the property by deed recorded in the Barnstable County Registry of Deeds on April 28, 2000 as recorded in Book 12974, Page 246. 3. On August 7, 2007 a site approval letter was issued for the property by Town Manager John Klimm, in accordance with MGL Chapter 40B and 760 CMR.Notice of the site approval letter was sent to the Department of Housing and Community Development, in accordance with the requirements of CMR 760, and no issues were communicated from the Department on this particular application. 4. The proposed accessory affordable unit is limited to 471 square feet square feet, and is located above the detached garage. 5. The applicant is aware that the unit must meet all applicable building codes to be occupied and that the Building Division and Fire Department will also be inspecting the unit for compliance with all applicable building and fire codes. 6. The house is served by public water and sewer and is in an identified Wellhead Protection Overlay District. The proposal has been reviewed by Thomas McKean, Health Director, and he has approved a total of four(4)bedrooms at the property. 7. On April 17, 2007 the applicant signed an Accessory Affordable Apartment Program Agreement Affidavit that commits, upon the receipt of a Comprehensive Permit,to the recording of a Regulatory Agreement and Declaration of Restrictive Covenants at the Barnstable Registry of Deeds. That document will restrict the unit in perpetuity as an affordable rental unit and requires that the dwelling be owner-occupied as her principal residence. 8. The applicant understands that the affordable unit will be rented to a person or family whose income is 80% or less of the Area Median Income(AMI) of the Barnstable Metropolitan Statistical Area(MSA)and further agrees that rent(including utilities) shall not exceed 30%of the monthly household income of a household earning 80% of the median income, adjusted by household size. In the event that utilities are separately metered, the utility allowance established by the town of Barnstable shall be deducted from rent level so calculated. 9. According to the Massachusetts Department of Housing and Community Development, as of September 26, 2007 6.63% of the town's year round housing stock qualifies as affordable housing units. The town has not reached the statutory minimum of affordable housing under MGL Chapter 40B Section 20-23 or its implementing regulations. The Town of Barnstable's Local Comprehensive Plan encourages the use of existing housing to create affordable units and the dispersal of these units throughout the town. 2 r Finding Summary: Based upon the findings, the Hearing Officer ruled that the applicant has standing to apply for a Comprehensive Permit under MGL Chapter 40B and the Town of Barnstable's Accessory Apartment Program. The proposal is also deemed consistent with local needs because it adequately promotes the objective of providing affordable housing for the town of Barnstable without jeopardizing the health and safety of the occupants provided all conditions of the Comprehensive Permit are strictly followed. Ruling and Conditions: Based upon the findings, a ruling was made to grant the Comprehensive Permit in accordance with MGL Chapter 40B to the applicant,Barbara Brown. It is issued to allow for a one-bedroom accessory affordable apartment unit in accordance with the following conditions: 1. Occupancy of the affordable unit shall not exceed two persons 2. The total number of bedrooms on the property shall not exceed three(3). 3. The property owner shall occupy the principal dwelling as her principal residence. 4. This unit shall not be occupied.by a family member of the owner(s). 5. All parking for the accessory apartment and the main dwelling shall be on-site and no lodging shall be permitted for the duration of the comprehensive permit. 6. To meet the requirements of affordability, the cost of housing(including utilities) shall not exceed 30% of'80% of the median income for a single individual for the Barnstable MSA. In the event that utilities are separately metered, the utility allowance established by the town of Barnstable shall be deducted from rent level so calculated. 7. All leases shall have a minimum term of one year. 8. The Growth Management Department shall serve as the monitoring agent for the accessory apartment. 9. The applicant must apply for a building permit for the accessory unit,whether the unit is new or pre-existing. Before securing an occupancy permit and certificate of compliance, the Building Commissioner must determine that the unit conforms with the approved plans as submitted with the. building permit application and meets state building and fire codes. The Health Division must determine that the dwelling is in compliance with applicable on-site wastewater discharge requirements. 10. The applicant may select her own tenant provided the tenant meets the requirements of the program as cited above and provided that person's income is reviewed and approved by the Growth Management Department of the town of Barnstable as a qualified individual. The applicant will be required to work with the town to provide information necessary to document that the tenant qualifies. The unit shall be rented on an open and fair basis to an income eligible individual or family. Whenever a vacancy occurs, notice must be given to the Growth Management Department and the unit must be listed with the Town.. 11. Every twelve months the applicant shall review the income eligibility of the individual occupying the unit. No later than a year from the date of issuance of this Comprehensive Permit, the applicant shall file with the Growth Management Department of the town of Barnstable an annual affidavit listing the rent charged and income level of the occupant of the unit. The applicant shall provide the town any additional information it deems necessary to verify the information provided in the affidavit. Upon any report from the town that the terms and conditions of this permit are not being upheld, the Zoning Board of Appeals or it's Hearing Officer shall have the ability to hold a hearing to show cause as to why this permit should not be revoked. 3 f 12. This Comprehensive Permit shall not be transferable to any other person or entity without the prior approval of the Hearing Officer or Zoning Board of Appeals. This decision, the Regulatory Agreement and Declaration of Restrictive Covenants and all other necessary documents shall be filed at the Barnstable County Registry of Deeds. If the ownership of the property is transferred, the Growth Management Department of the town of Barnstable shall be notified within 60 days of the name and address of the new owner. 13. This Comprehensive Permit must be exercised and the unit occupied within 12 months of its issuance or it shall expire. Ordered: Comprehensive Permit 2007-091 has been granted with conditions. A written copy of this decision shall be forwarded to the Zoning Board of Appeal as required by the Town of Barnstable Administrative Code Chapter 241, section 11. If after fourteen (14)days from that transmittal the Members of the Zoning Board of Appeals takes no action to reverse the decision,this decision shall become final and a copy shall be the filed in the office of the Town Clerk. Appeals of the final decision, if any, shall be made to the Barnstable Superior Court pursuant to MGL Chapter 40A, Section 17,within twenty(20) days after the date of the filing of this decision in the office of the Town Clerk. The applicant has the right to appeal this decision as outlined in MGL Chapter 40B, Section 22. In accordance with Chapter 241, section 11 of the Town of Barnstable Administrative Code, the hearing officer transmitted a written copy of the Comprehensive Permit decision to the Zoning Board of Appeals on September 26, 2007. Fourteen (14)days have elapsed since the transmittal to the Board, and no Board Member has taken action to reverse the decision. �/I A�' G Nightingale, I acing Of er Date Signed 1, Linda Hutchenrider, Clerk of the Town of Barnstable, Barnstable County, Massachusetts,.hereby certify that twenty(20) days have elapsed since the Zoning Board of Appeals filed this decision and that no appeal of the decision has een filed in the office of the Town Clerk. Signed and sealed this l �w day of �� u der the pains.and penalties of perjury: i' Al Linda Hutchenrider,Town Clerk 4 Bk 22609 Ps219 -�`2692 REGULATORY AGREEMENT AND DECLARATJON OF RESTRICTIVE COVENANTS THIS REGULATORY AGREEMENT and DECLARATION OF RESTRICTIVE COVENANT'S,is made this Jr� day of . e1tR ,2008,by and between Barbara M. Brown aka Barbara M.Haskell of 161 Ridgewood Avenue,Hy Innis,MA and its successors and assigns (hereinafter the "Owner"),and the TOWN OF BARNSTABLE (the "Municipality"),a political subdivision of the Commonwealth; WHEREAS the Owner has been granted a Comprehensive Permit under Massachusetts General Law Chapter 40B and local regulations by the Zoning Board of Appeals to permit the creation of an accessory apartment in an owner occupied dwelling which will be rented to a Low or Moderate Income Person/ Family(hereinafter "Designated Affordable Unit");and NOW THEREFORE,in mutual consideration of the agreements and covenants contained herein, and other good and valuable consideration,the receipt and sufficiency of which is hereby acknowledged,the parties agree as follows: I. PROJECT SCOPE AND DESIGN: A- The terms of this Agreement and Covenant regulate the property located at 161 Ridgewood Avenue, Hyannis, MA as further described in deed recorded herewith as Barnstable County Registry of Deeds Book 4565,Page 019. B. The Project located at 161 Ridgewood Avenue,Hyannis,MA will consist of one accessory apartment unit which will be rented to an eligible low or moderate income individual or family(the "Designated Affordable Unit" or the "Unit"). C. The Owner agrees to construct the Project in accordance with the terms of comprehensive permit Appeal No. 2007-091 and any plans submitted therewith and all applicable state, federal and municipal laws and regulations. Said permit is recorded herewith as Barnstable County Registry of Deeds Book 22(POOI Page 21S D. The Owner agrees to occupy the principal dwelling unit located on the property as their principal residence in accordance with the terms of the comprehensive permit. II. THE OWNER'S COVENANTS AND RESPONSIBILITIES: A. THE OWNER HEREBY REPRESENTS,COVENANTS AND WARRANTS AS FOLLOWS: 1 In receiving the comprehensive permit to create the Designated Affordable unit,the Owner agreed that the Designated Affordable Unit shall be set aside in perpetuity for the public purpose of providing safe and decent housing to persons earning at or below 80% of the area median income of Barnstable Metropolitan Statistical Area (MSA) and that the Designated Affordable Unit shall be deemed to be impressed with a public trust. 2. The Designated Affordable Unit shall be rented in perpetuity to a household with a maximum income of 80% of the Area Median Income (AMI) of Barnstable MSA and that rent (including utilities) shall not exceed an , amount that is affordable to a household whose income is 80% of the median income of Barnstable MSA In the event hat utilities are separately metered,a utility allowance established by the Barnstable Housing Authority shall be deducted from the rent level. 3. The Designated Affordable Unit will be retained as a permanent,year round rental dwelling unit with at least a one-year lease. 4. The Owner has the full legal right,power and authority to execute and deliver this Agreement. 5. The execution and performance of this Agreement by the Owner will not violate or, as applicable,has not violated any provision of law,rule or regulation,or any order of any court or other agency or governmental l , body,and will not violate or,as applicable,has not violated any provision of any indenture,agreement,mortgage, mortgage note,or other instrument to which the Owner is a party or by which it or the Owner is bound,will not result in the creation or imposition of any prcthibited encumbrance of any nature. 6. The Owner,at the time of execution and delivery of this Agreement,has good,clear marketable title to the premises. 7. There is no action,suit or proceeding at law or in equity or by or before any governmental instrumentality or other agency now pending,or,to the knowledge of the Owner,threatened against or affecting it,or any of its properties or rights,which,if adversely determined,would materially impair its right to carry on business substantially as now conducted (and as now contemplated by this Agreement) or would materially adversely affect its financial condition. B. COMPLIANCE The Owner hereby agrees that any and all requirements of the laws of the Commonwealth of Massachusetts to be satisfied in order for the provisions of this Agreement to constitute restrictions and covenants running with the land shall be deemed to be satisfied in full and that any requirements of privileges of estate are also deemed to be satisfied in full. C. LIMITATION ON PROFITS 1. The Owner agrees to limit his/her profit by renting the Designated Affordable Unit in perpetuity to a household with a maximum income of 80% or less of the Area Median Income (AMI) of Barnstable Metropolitan Statistical Area (MSA) and that rent(including utilities) shall not exceed an amount that is affordable to a household whose income is 80% of the median income of Barnstable MSA. In the event that utilities are separately metered,a utility allowance established by the Barnstable Housing Authority shall be deducted from the rent. 2. The Owner shall annually deliver to the Municipality and to the Monitoring Agent,as designated by the Town Manager,proof that the Designated Affordable Unit is rented,the tenant's income verification,a copy of the lease agreement and the rent charged for the unit or units. Such information shall also be forwarded to the Monitoring Agent within 30 days of the occupation of the dwelling unit or units by a new tenant. The Owner shall notify the Monitoring Agent,as designated by the Town Manager,within thirty(30) days of the date that a tenant has vacated the Designated Affordable Unit. III. MUNICIPALITY COVENANTS AND RESPONSIBILITIES 1. The MUNICIPALITY,through the monitoring agent designated by the Town Manager agrees to perform the duties of verifying that the Designated Affordable Unit is being rented in perpetuity to a household with a maximum income of 80% or less of the Area Median Income (AMI) of Barnstable MSA and that rent (including utilities) shall not exceed an amount that is affordable to a household whose income is 80% of the median income of Barnstable MSA In the event that utilities are separately metered,a utility allowance established by the Barnstable Housing Authority shall be deducted from the rent. IV. RECORDING OF AGREEMENT: Upon execution,the OWNER shall immediately cause this Agreement and any amendments hereto to be recorded with the Registry of Deeds for Barnstable County or,if the Pro)ect consists in whole or in part of registered land,file this Agreement and any amendments hereto with the Registry District of the Barnstable Land Court (collectively hereinafter the "Registry of Deeds"), and the Owner shall pay all fees and charges incurred in connection therewith. Upon recording or filling,as applicable,the Owner shall immediately transmit to the Municipality evidence of such recording or filing including the date and instrument,book and page or registration number of the Agreement. 2 I V. GOVERNING OF AGREEMENT: This Agreement shall be governed by the laws of the Commonwealth of Massachusetts. Any amendments to this Agreement must be in writing and executed by all of the parties hereto. The invalidity of any clause,part or provision of this Agreement shall not affect the validity of the remaining portions hereof. VI. NOTICE: All notices to be given pursuant to this Agreement shall be in writing and shall be deemed given when delivered by hand or when mailed by certified or registered mail,postage prepaid,return receipt requested,to the parties hereto at the addresses set forth below,or to such other place as a party.may from time to time designate by written notice. VII. HOLD HARMLESS: The Owner hereby agrees to indemnify and hold harmless the Municipality and/or its delegate from any and all actions or inactions by the Owner,its agents,servants or employees which result in claims made against Municipality and/or its delegate,including but not limited to awards,judgments,out-of-pocket expenses and attorneys fees necessitated by such actions. V1II. ENTIRE UNDERSTANDING: A. This Agreement shall constitute the entire understanding between the parties and any amendments or changes hereto must be in writing,executed by the parties,and appended to this document. B. This Agreement and all of the covenants, agreements and restrictions contained herein shall be deemed to be_for the public purpose of providing safe affordable housing and shall be deemed to be, and by these presents are, granted by the Owner to ran in perpetuity in favor of and be held by the Municipality as any other permanent restriction held by a governmental body as that term is used in MGL Ch. 184, Section 26 which shall run with the land described in deed recorded herewith as Barnstable County Registry of Deeds Book 4565, Page 019 and shall be binding upon the Owner and all successors in title . This Agreement is made for the benefit of the Municipality and the Municipality shall be deemed to be the holder of the restriction created by this Agreement. The Municipality has determined that the acquiring of such a restriction is in the public interest. The Municipality shall not be subject to the defense of lack of privity of estate. The covenants and restrictions contained in this Agreement shall be deemed to affect the title to the property described in deed recorded herewith as Barnstable County Registry of Deeds Book 4565,Page 019. IX. TERM OF AGREEMENT: The term of this Agreement shall be perpetual,provided,however,that the Owner of a Designated Affordable Unit or Units may voluntarily cancel the granted Comprehensive Permit and the terms and restrictions imposed herein. Such cancellation shall only take effect after: 1) expiration of the lease terms entered into between the Owner and Tenant occupying said unit and 2) notification by the Owner of said dwelling to the Zoning Board of Appeals of his/her desire to cancel the Comprehensive permit upon a date certain and the recording of said notice at the Barnstable County Registry of Deeds or Barnstable County Registry of the Land Court as the case may be,thus rendering said Comprehensive Permit void. Upon the cancellation of the comprehensive permit,the property which is the subject matter of this restrictive covenant shall revert to the use permitted under zoning and the restrictive covenant shall be rendered void. 3 X. SUCCESSORS AND ASSIGNS: A. The Parties to this Agreement intend,declare,and covenant on behalf of themselves and any successors and assigns their rights and duties as defined,in this Regulatory Agreement and the attached comprehensive permit. B. The Owner intends,declares,and covenants on behalf of itself and its successors and assigns (i) that this Agreement and the covenants,agreements and restrictions contained herein shall be and are covenants running with the land,encumbering the Project for the term of this Agreement, and are binding upon the Owner's successors in title, (ii) are not merely personal covenants of the Owner,and (iii) shall bind the Owner,its successors and assigns and inure to the benefit.of the Municipality and its successors and assigns for the term of the Agreement. M. DEFAULT: If any default,violation or breach by the Owner of this Agreement is not cured to the satisfaction of the Monitoring Agent within thirty(30) days after notice to the Owner thereof,then the Monitoring Agent may send notification to the Municipality that the Owner is in violation of the terms and conditions hereof. The Municipality may exercise any remedy available to it. The Owner will pay all costs and expenses,including legal fees,incurred by the Monitoring Agent in enforcing this Agreement and the Owner hereby agrees that the Municipality and the Monitoring Agent will have alien on the Project to secure payment of such costs and expenses. The Monitoring Agent may perfect such alien on the Project by recording a certificate setting forth the amount of the costs and expense due and owing in the Registry of Deeds or the Registry of the District Land Court for Barnstable County. A purchaser of the Project or any portion thereof will be liable for the payment of any unpaid costs and expenses that were the subject of a perfected lien prior to the purchaser's acquisition of the Project or portion thereof. XII. MORTGAGEE CONSENT: . I The Owner represents and warrants that it has obtained the consent of all existing mortgagees of the Project to the execution and recording of this Agreement and to the terms and conditions hereof and that all such mortgagees have executed consent to this Agreement. IN WITNESS WHEREOF,we hereunto set our hands and seals this3Zc1day 2008. OWNER BY: Signature Printed:Barbara M Brown aka Barbara M.Haskell COMMONWEALTH OF MASSACHUSETTS County of Barnstable,ss: On this?X c/day L,. 4M2008 before me,the undersigned notary public,personally appeared �Bd/t/Q/?q A t\ Aa zi, o the Owner(s),proved to me through satisfactory evidence of identification,which were L) C /�,'C �e�c P_ us S 1 ,to be the person(s) whose name(s) is signed on the preceding or attached document and acknowledged to be that he/she signed'it voluntarily for the stated purposes. 4-5*kk --ADMINE At WELCH Notary Public rrPUW Printed: f z 4 TOWN OF B STABLE BY: TOWN MANAGER COMMONWEALTH OF MASSACHUSETTS County of Barnstable,ss: On this j "day of 2008 before me,the°undersigned notary public,personally appeared n (� K�-i m rv-i,the own Manager for the Town of Barnstable,proved to me through satisfactory c! n' evidence of identification,which were U't�✓ ,to be the person whose name is signed on the preceding or attached document and acknowledg dd to be signed it voluntarily for the stated purposes. 0 ,�j /- No ry Public Printed: �f I l��P��. �G`� My Commission Expires: OFFICIAL SHIRLEE MA Y PMUCAd{USETTS - - ' coNfJON`�`LTHOF �8n008 lvty Comm. 5 TOWN OF BARNSTABLE BUILDING PERMIT APP ICATION M 3d2 Parcel �0100 lication# �D0(0 0703 Health Division Conservation Division nn O Permit# Tax Collector 9 00 42 Oa r�� , /„� Date Issued Treasurer Application Fee4,160-00 Planning Dept. Permit Fee Date Definitive Plan Approved by Planning Board l � Historic-OKH Preservation/Hyannis Project Street Address &I ? woo n A A Village T/� iJis Owner '2j,4z 34A4 '732®.O'J Address -e Telephone 6-99_ 0'6.2 —0/97 Permit Request 7)I CL e_. &b �Wo C,42 17A2.4q^G WAc ba F/002 w 87 k 4 -&,tr# Square feet: 1st floor:existing & 76 proposed A 76 2nd floor:existing proposed Total new,67o Zoning District 9 F Flood Plain Groundwater Overlay Project Valuation D 0 •� Construction Type 1&1 d/ Lot Size 137 9 Grandfathered: R*Ies ❑No If yes, attach supporting documentation. Dwelling Type: Single Family ❑ Two Family ❑ Multi-Family(#units)) Age of Existing Structure 5-0 AS Historic House: ❑Yes V<O On Old King's Highway: ❑Yes Mlfio Basement Type: ❑ C�Full ❑Crawl ❑Walkout Other l'LosT UJAtt S Basement Finished Area(sq.ft.) Basement Unfinished Area(sq.ft) Number of Baths: Full:existing new Half:existing new Number of Bedrooms: existing new `Total Room Count(not including baths):existing new 41� First Floor Room Count Heat Type and Fuel: ❑Gas ❑Oil ZEctric ❑Other Central Air: ❑Yes Zo Fireplaces: Existing New Existing wood/coal_siove: L Yes rC�3'No Detached garage:❑existing 2i new size Pool:❑existing ❑new size Barn:❑existing ❑new size Attached garage:❑existing ❑new size Shed:❑existing ❑new size Other: i :9 - } Zoning Board of Appeals Authorization ❑ Appeal# Recorded❑ � Commercial Cl Yes Flo If yes, site plan review# - Current Use Proposed Use BUILDER INFORMATION Name P)PZ Telephone Number Sbk Rba OLTI Address 44,0 ( —ll�C��� � License# ti U Home Improvement Contractor# Worker's Compensation# ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO SIGNATURE DATE 5' as -0 FOR OFFICIAL USE ONLY PERMIT.NO. DATE ISSUED b' MAP/PARCEL NO. 1 ADDRESS VILLAGE OWNER DATE OF INSPE ION: FOUND:A�TION INSLSOgj F ACE 0 , kB RICAL: ROUGH FINALII ROUGH FINAL GAS: ROUGH FINAL �r FINAL BUILDING DATE CLOSED OUT ' T ASSOCIATION PLAN . - Town of Barnstable NP Regulatory Services BABNSTABLE, Thomas F.Geiler,Director 9 MASS. �. 059• s,� Building Division rF0 MA't Tom Perry,Building Commissioner 200 Main Street, Hyannis,MA 02601 www.town.barnstable.ma.us Office: 508-862-4038 Fax: 508-790-6230 HOMEOWNER LICENSE EXEMPTION Please Print DATE: S/d_� 0 6 7 JOB LOCATION: 161 12 t o14 e t d oo t5 AIAI 4.4 Ol�Oj number street vil ge "HOMEOWNER": b>Ai2 Arta �/1�c��-3 5-PI-P44 —at 47 name home phone# work phone# CURRENT MAII NG ADDRESS: P0, 13 / �'NA1UA)�s city/tovefi state zip code The current exemption for"homeowners"was extended to include owner-occupied dwellings of six units.or less and to allow homeowners to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor. DEFINITION OF HOMEOWNER Person(s)who owns a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two-family dwelling,attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such "homeowner"shall submit to the Building Official on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. (Section 109.1.1) The undersigned"homeowner"assumes responsibility for compliance with the State Building Code and other applicable codes,bylaws,rules and regulations. The undersigned"homeowner"certifies that he/she understands the Town of Barnstable Building Department minimum inspection procedures and requirements and that he/she will comply with said procedures and require en` , /J Signature of Homeowner Approval of Building Official Note: Three-family dwellings containing 35,000 cubic feet or larger will be required to comply with the State Building Code Section 127.0 Construction Control. . HOMEOWNER'S EXEMPTION The Code states that: "Any homeowner/performing work for which a building permit is required shall be exempt from the provisions of this section(Section 109.1.1-Licensing of construction Supervisors);provided that if the homeowner engages a person(s)for hire to do such work,that such Homeowner shall act as supervisor." Many homeowners who use this exemption are unaware that they are assuming the responsibilities of a supervisor(see Appendix Q, Rules&Regulations for Licensing Construction Supervisors,Section 2.15) This lack of awareness often results in serious problems,particularly when the homeowner hires unlicensed persons. In this case,our Board cannot proceed against the unlicensed person as it would with a licensed Supervisor. The homeowner acting as Supervisor is ultimately responsible. To ensure that the homeowner is fully aware of his/her responsibilities,many communities require,as part of the permit application, that the homeowner certify that he/she understands the responsibilities of a Supervisor. On the last page of this issue is a form currently used by several towns. You may care t amend and adopt such a form/certification for use in your community. Q:fonns:homeexempt The Commonwealth of'Massachusetts Department of Industrial Accidents A Office of Investigations ~� a 600 Washington Street Boston, AM 02111 ww411.mas&gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Apulicant Information Please Pit Legibly Name (Business/Organizatiowhdividual): &A215AA.A �200JfJ Address: D City/State/Zip: :H*t► h1;s MA. O)L( 0( Phone#: Are you an employer? Check the appropriate box: Type 9f project(required): 1.❑ I am a employer with 4• ❑ I am a general contractor and I 6. New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet $ 7• ❑ Remodeling ship and have no employees These sub-contractors have S•. ❑ Demolition working for me in any capacity. workers' comp, insurance. g. ❑ Building addition [No workers' Comp. insurance 5. ❑ We are a cdrporation and its 1 required.] officers have exercised their 10.❑ Electrical repass or additions 3. / I am a homeowner doing all work - right of exemption per MGL mF. kambing repairs or additions t myself.[No workers' comp. c. 152,§1(4),and we have no 12.❑ Roof repairs insurance required.] t employees. [No workers' 1,3. Other comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information: t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and their workers'comp.policy information. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy andjob site information. Insurance Company Name: Policy#or Self-ins.Lic. #: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500..00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correcr. Signature: _ Date: /7-b C Phone#: 0 N �6,--� 0197 Official use only. Do not write in this area,to be completed by city or town official 1 e City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk a.Electrical inspector S.Plumbing Inspector � 6. Other Contact Person: Rhone#: Information and Instructions ,r Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute, an employee is defined as"...every person in the service of another under any contract of hire, , express or implied,oral or written." An employer is defined as "an individual,partnership, association, corporation or other legal entity, or any two or more of the foregoing engaged in a joint enterprise, and including the legal representatives of a deceased employer, or the . ' receiver or trustee of an individual,partnership, association or other legal entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein, or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152, §25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally,MGL chapter 152, §25C(7)states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely,by checking the boxes that apply to your situation and, if necessary, supply sub-contractors)name(s),address(es)and phone number(s)along with their certificate(s) of insurance. Limited Liability Companies(LLC)or Limited Liability Partnerships(LLP)with no employees other than the members or partners, are not required to carry workers' compensation insurance. If an LLC or LLP does have employees,a policy is required. Be advised that this affidavit may be submitted to the Department of industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested, not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy,please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials . Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom. of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant Please be sure to fill in the permit/license number which will be used as a reference number. In addition,an applicant that must submit multiple permit/license applications in any given year,need only submit one affidavit indicating current policy information(if necessary)and under"Job Site Address"the applicant should write"all locations in (city or town)."A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year.Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture i.e. a do license or permit to burn leaves etc. said person is NOT required to complete this affidavit. ( g P ) P eq The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address,telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 600 Washington Street Boston, MA 02111 Te1. 474F 617-727-4900 ent 406 or 1-877-NASSAFE Fax #617-727-7749 Revised 5-26-05 v,T�v�%,f.rrr.aSS.g0Y/Gla oF +ET Town of Barnstable Regulatory Services HAM. Thomas F.Geiler,Director 8' Building Division Tom Perry,Building Commissioner 200 Main Street, Hyannis,MA 02601 Office: 508-8624038 Fax: 508-790-6230 Permit no. Date AFFIDAVIT HOME IMPROVEMENT CONTRACTOR LAW SUPPLEMENT TO PERMIT APPLICATION �. MGL c. 142A requires that the"reconstruction,alterations,renovation,repair,modernization,conversion, improvement,removal,demolition,or construction of an addition to any pre-existing owner-occupied building containing at least one but not more than four dwelling units or to structures which are adjacent to such residence or building be done by registered contractors,with certain exceptions,along with other requirements. Type.of Work: GA .Q, Estimated Cost 000 Address of Work: 16 t R;d e k) Jt '� �/�i 5 144. O.Z Owner's Name: 'AR?,y,: 1_3" A) Date of Application: /7 06 I hereby certify that: Registration is not required for the following reason(s): ❑Work excluded by law ❑JQb Under$1,000 Building not owner-occupied [90wner pulling own permit Notice is hereby given that: OWNERS BULLING THEIR OWN PERMIT OR DEALING WITH UNREGISTERED CONTRACTORS FOR APPLICABLE HOME IMPROVEMENT WORK DO NOT HAVE ACCESS TO THE ARBITRATION PROGRAM OR GUARANTY FUND UNDER MGL c.142A. SIGNED UNDER PENALTIES OF PERJURY I hereby apply for a permit as the agent of the owner: Date Contractor Name Registration No. OR Date Owner's Name Q:fomislomeaffidav I RESIDENTIAL BUILDING PERMIT FEES APPLICATION FEE New Buildings $100.00 Residential Addition $ 50.00 Alterations/Renovations $ 50.00 Change of Contractor/Builder $25.00 FEE VALUE WORKSHEET NEW LIVING SPACE square feet x$96/sq. foot= x .0041= plus from below(if applicable) ALTERATIONS/RENOVATIONS OF EXISTING SPACE square feet x$64/sq.foot= x .0041= plus from below(if applicable) GARAGES(attached&detached) I square met x$32/sq. ft. = x .0041= ACCESSORY STRUCTURE>120 sq. ft. >120 sf-500 sf $ 35.00 >500 sf-750 sf 50.00 >750 sf- 1000 sf 75.00 >1000 sf- 1500 sf 100.00 >1500 sf-Same as new building permit: square feet x$96/sq.foot= x .0041= STAND ALONE PERMITS Open Porch x$30.00= (number) Deck x$30.00= (number) Fireplace/Chimney x$25.00= (number) Inground Swimming Pool $60.00 Above Ground Swimming Pool $25.00 Relocation/Moving $150.00 (plus above if applicable) Permit Fee Projcost Rev:063004 i Boisw Tri'pie 1-3/4" x 14" VERSA-LAM® 3100 SP Floor Beam\Level 102 BC CALCO 9.2 Design Report-US 3 spans No cantilevers 1 0/12 slope Wednesday, May 17,2006 16:20 Build 141 File Name: DeMartin Haskell.BCC Job Name: Haskell Garage Description: Main Girt carring room over garage Address: Specifier: be City, State,Zip: Hyannis, Ma Designer: Customer: Bert Demartin Company: Shepley Wood Products Code reports: ICBO 5512, NER 629 Misc: 1 1 wo' r `mom WAIN 1'2_1211=2 06-06-00 A13-00-00 06-06-00 BO, 1-3/4" B1,3-1/2" B2,3-1/2" B3, 1-3/4" LL 2136 Ibs LL 8330 Ibs LL 8330 Ibs LL 2136 Ibs DL 611 Ibs DL 4975 Ibs DL 4975 Ibs DL 611 Ibs SL 392 Ibs SL 3196 Ibs SL 3196 Ibs SL 392 Ibs Total of Horizontal Design Spans=26-00-00 Load Summary Live Dead Snow Wind Roof Live Tag Description Load Type Ref. Start End 100% 90% 116% 133% 125% Trib. 2 Joist plf Unf. Lin. Left 00-00-00 26-00-00 701 plf 409 plf 276 plf n/a Controls Summary Value %Allowable Duration Load Case Span Location Disclosure Pos. Moment 13926 ft-Ibs 27.8% 115% 15 2- Internal Completeness and accuracy of input must Neg. Moment -17178 ft-Ibs 34.3% 115% 19 2-Right be verified by anyone who would rely on End Shear 1345 Ibs 9.5% 100% 14 1 -Left output as evidence of suitability for Cont. Shear 7440 Ibs 45.5% 115% 17 2-Left particular application.Output here based Uplift 528 Ibs n/a 16 1 -Left on building code-accepted design properties and analysis methods. Uplift 528 Ibs n/a 16 3-Right Installation of BOISE engineered wood Total Load Defl. U1143 (0.136") 21.0% 15 2 products must be in accordance with Live Load Defl. U1575 (0.099") 22.9% 15 2 current Installation Guide and applicable Total Neg. Defl. -0.02" 3.9% 15 1 building codes.To obtain Installation Guide Max Defl. 0.136" 13.6% 15 2 or ask questions, please call Span/Depth 11.1 n/a 2 (800)232-0788 before installation. BC CALCO, BC FRAMER@,AJS-, Cautions ALLJOISTO,BC RIM BOARDTM,BCIO, Uplift of 528 Ibs found at span 1 - Left. BOISE GLULAM- SIMPLE FRAMING UUplift of 528 Ibs found at span 3-Right. SYSTEM@,VERSA-LAM@,VERSA-RIM P p 9 PLUS@,VERSA-RIM@, VERSA-STRANDTM,VERSA-STUD@ are Notes trademarks of Boise Wood Products, Design meets Code minimum(U240)Total load deflection criteria. L.L.C. Design meets Code minimum (U360) Live load deflection criteria. Design meets arbitrary (1") Maximum load deflection criteria. Minimum bearing length for BO is 1-1/2". Minimum bearing length for B1 is 3-3/4". Minimum bearing length for B2 is 3-3/4". Minimum bearing length for B3 is 1-1/2". Entered/Displayed Horizontal Span Length(s)=Clear Span+ 1/2 min. end bearing+ 1/2 intermediate bearing Connection Diagram - b -d a c \ 77 a minimum=2" c= 5" b minimum=3" d = 12" e minimum=3" Nailing schedule applies to both sides of the member. Member has no side loads. @i c3td) Ire: 16d Sinker Nails Boisw Single 9-1/2" AJSTM 20 MSR Joisftevel 1\D1 BC CALCO 9.2 Design Report- US 2 spans I No cantilevers 1 0/12 slope Wednesday, May 17,2006 16:16 Build 141 16"OCS Repetitive Glued&nailed construction File Name: DeMartin Haskell.BCC Job Name: Haskell Garage Description: Level 101 Address: Specifier: be City, State,Zip: Hyannis, Ma Designer: Customer: Bert Demartin Company: Shepley Wood Products Code reports: ESR-1144 Misc: s � 4 5 2 3 12-10-14 12-10-14 -` BO,4-318" 131,5-1/4" B2,4-3/8" LL 404 Ibs LL 935 Ibs LL 404 Ibs DL 373 Ibs DL 545 Ibs DL 373 Ibs SL 336 Ibs SL 368 Ibs SL 336 Ibs Total Horizontal Product Length=25-09-12 Load Summary Live Dead Snow Wind Roof Live Tag Description Load Type Ref. Start End 100% 90% 115% 133% 125% OCS 1 Standard Load Unf.Area Left 00-00-00 25-09-12 40 psf 10 psf 16" 2 wall Conc. Lin. Left 03-04-00 03-04-00 0 plf 60 plf 16" 3 wall Conc. Lin. Right 03-04-00 03-04-00 0 plf 60 plf 16" 4 ceiling Conc. Lin. Left 03-04-00 03-04-00 100 plf 100 plf 16" 5 ceiling Conc. Lin. Right 03-04-00 03-04-00 100 plf 100 plf 16" 6 Roof Conc. Lin. Left 03-04-00 03-04-00 195 plf 390 plf 16" 7 Roof Conc. Lin. Right 03-04-00 03-04-00 195 plf 390 plf 16" Controls Summary Value %Allowable Duration Load Case Span Location Disclosure Pos. Moment 3002 ft-Ibs 76.8% 115% 13 1 - Internal Completeness and accuracy of input must Neg. Moment -2933 ft-Ibs 75.1% 115% 17 2-Left be verified by anyone who would rely on End Reaction 1089 Ibs 68.2% 115% 15 2-Right output as evidence of suitability for Int. Reaction 1818 Ibs 54.0% 115% 2 1 -Right particular application.Output here based 0 0 on building code-accepted design Cont. Shear 909 Ibs 68.2/0 115/0 2 1 -Right properties and analysis methods. Total Load Defl. U582 (0.26") 41.2% 13 1 Installation of BOISE engineered wood Live Load Defl. U831 (0.182") 57.7% 13 1 products must be in accordance with Total Neg. Defl. -0.033" 6.5% 14 2 current Installation Guide and applicable Max Defl. 0.26" 26.0% 13 1 building codes.To obtain Installation Guide Span/Depth 15.9 n/a 2 or ask questions,please call (800)232-0788 before installation. %Allow %Allow BC CALCO,BC FRAMER@,AJSTM, Bearing Supports Dim.(L x W) Value Support Member Material ALLJOISTO, BC RIM BOARD TM,BCIO, BO Wall/Plate 4-3/8"x 2-1/2" 1113 Ibs n/a n/a Unspecified BOISE GLULAMT"' SIMPLE FRAMING B1 Beam 5-1/4"x 2-1/2" 1848 Ibs 16.6% n/a Versa-Lam SP SYSTEM@,VERSA-LAMS,VERSA-RIM B2 Wall/Plate 4-3/8"x 2-1/2" 1113 Ibs n/a n/a Unspecified PLUS@,VERSA-RIM@, p VERSA-STRAND ,VERSA-STUD@ are trademarks of Boise Wood Products, Cautions L.L.C. Web stiffeners are always required under concentrated loads that exceed 1000 lbs. Install the web stiffeners snug to the top of the flange. Follow the nailing schedule for intermediate bearings. Notes Design meets Code minimum (L/240)Total load deflection criteria. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary(1") Maximum load deflection criteria. Composite El value based on 23/32"thick sheathing glued and nailed to joist. Page 1 of 1 6 7 97 Town of Barnstable Approved Regulatory Services Fee C D Thomas F.Geiler,Director Building Division Tom Perry,Building Commissioner 200 Main Street, Hyannis,MA 02601 d Office: 508-862-4038 Fax: 508-790-6230 Home Occupation Registration Date: � � �3 Name: 7,zn zjS 40(I)N Phone#: t5o46- 7.78 93/3 Address: KId --loan( Al Village: f 114AJ viS Name of Business: AR �(✓,�Dri.�7 �/T�J�/�2f�iiV 4 Type of Business: C� f�l C� Map/Lot: 32 8 Zoning District AS Zoning Districts RF and RC-1 require Special Permit from Zoning Board of Appeals. INTENT: It is the intent of this section to allow the residents of the Town of Barnstable to operate a home occupation within single family dwellings,subject to the provisions of Section 4-1.4 of the Zoning ordinance,provided that the activity shall not be discernible from outside the dwelling: there shall be no increase in noise or odor;no visual alteration to the premises which would suggest anything other than a residential use;no increase in traffic above normal residential volumes; and no increase in air or groundwater pollution.- After registration with the Building Inspector, a customary home occupation shall be permitted as of right subject to the following conditions: • The activity is carried on by the permanent resident of a single family residential dwelling unit,located within that dwelling unit. • Such use occupies no more than 400 square feet of space. • There are no external alterations to the dwelling which are not customary in residential buildings,and there is no outside evidence of such use. • No traffic will be generated in excess of normal residential volumes. • The use does not involve the production of offensive noise,vibration, smoke, dust or other particular matter, odors,electrical disturbance,heat,glare,humidity or other objectionable effects. • There is no storage or use of toxic or hazardous materials,or flammable or explosive materials,in excess of normal household quantities. • Any need for parking generated by such use shall be met on the same lot containing the Customary Home Occupation, and not within the required front yard. • There is no exterior storage or display of materials or equipment. • There is no commercial vehicles related to the Customary Home Occupation,other than one van or one pick-up truck not to exceed one ton capacity,and one trailer not to exceed 20 feet in length and not to exceed 4 tires,parked on the same lot containing the Customary Home Occupation. • No sign shall be displayed indicating the Customary Home Occupation. • If the Customary Home Occupation is listed or advertised as a business,the street address shall not be included. • No person shall be employed in the Customary Home Occupation who is not a permanent resident of the dwelling unit. I,the undersigned,have read and agree with the above restrictions for my home occupation I am registering. Applicant: Date: 02-Q 03 Homeoc.doc r Y TOWN OF BARNSTABLE Permit No:32775 s � BUILDING DEPARTMENT TOWN OFFICE BUILDING Cash HYANNIS,MASS.02601 Bond ,N f A..,.... CERTIFICATE OF USE AND OCCUPANCY Issued to Address Lot #29, 27 Kilkore Drive Hvannis, Mass. USE GROUP FIRE GRADING OCCUPANCY LOAD THIS PERMIT WILL NOT BE VALID, AND THE BUILDING SHALL NOT BE,OCCUPIED UNTIL SIGNED BY THE BUILDING INSPECTOR UPON SATISFACTORY COMPLIANCE WITH TOWN REQUIREMENTS AND.IN ACCORDANCE WITH SECTION 119.0 OF THE MASSACHUSETTS STATE BUILDING CODE. �? AuC�u s t 1 ... 19 8 9 / 2%�- --- ........ .... ........ .Jy ... ....... ........... Building Inspector r s' � �.- A c. - - - .'7ti�'rr"-.8s.c =,��em+�+e. S•y,,,• yi, ?�.:+f nF = ;:x x LE BUILDINGS PI�RNIIT a BARNSTABLE, MASSACHUSETTS - 005-013 '� April 6 89 DATE n nt9 i]r,a- c 1 �EF IolTnti , Greenbrier Corp. . .tea--5 4 APPLICANT - ADDRESS `0 "` ` (NO.) '(STREET) ICONTR S•L�CENSEI Dwelling, 1$ Single Family :DwellingN'uMSEAr of r µyid PERMIT t0' " (_1 STORY OWE- I,, UNITS ' F} =4 x e^,a•t•rt I: .(PROPOSED USE)s; ,•..�wp..H »y�..r StrG„�o:i� s.=. RAY'le _'ITYPE OF'1MPROVEMENT) - N0. rlyci- A. (LQCATION) DISTRICT , r 'l (NO:) (STREET) BETY�c£ .AND �',1BEVTWEEN ., '(CROSS'STREET): • � fCR055`STREET) .de-...+:� ..w:ya..s., LOT SUBDIVISION LOT BLOCK. SIZE t .. :. .. .. _ .r • e p::... (SN�lA BUILDINGAS TO BE FT. WIDE BY F7, LONG BY ,FT IN HEIGHT,'AND SHALL CONFORM IN CONSTRUCTION r TO TYPQ USE GROUP BASEMENT WALLS OR FOUNDATION a S S - (TYPE) i s rr �,�•ra'�x-. Sewage 311.3 ° ' REMARKS: - 3 /1bEA-OR:; 76.8 scq., ft. y 45:/OOO.YO PERsMIT } x�A JV .� VOLUME ESTIMATED COST $ -FEE (CUBIC r / OUAR E'FEET) 3 -n 'Favtt n, Greenbrier G�op. L OWNER le , QUILDING DE PT .ADDRESS,. BY r1, s }7 -S r"F 7T >c L.+�1 I �q+ t•.(,4•+fa"k' 14 `3� {r.�s'"#tv t a Ft - ABC-CJIVQ , OF ANY APPLICABLE SUBDIVISION R-ESTRICTIONS. MINIMUM .OF THREE CALL APPROVED PLANS MUST BE RETAINED ON JOB AND THIS WHERE APPLICABLE SEPARATE INSPECTIONS REQUIRED FOR CARD KEPT POSTED UNTIL FINAL INSPECTION HAS BEEN PERMITS ARE REQUIRED FOR ... ALL CONSTRUCTION WORK: ELECTRICAL, PLUMBING AND 1. FOUNDATIONS OR FOOTINGS. MADE. WHERE A CERTIFICATE OF OCCUPANCY IS RE- MECHANICAL INSTALLATIONS. i 2. PRIOR TO COVERING STRUCTURAL QUIRED,SUCH BUILDING SHALL NOT BE OCCUPIED UNTIL MEMBERS IN PE TI TO BEFORE FINAL INSPECTION HAS BEEN MADE. 3. FINAL INSPECTION BEFORE OCCUPANCY. POST THIS CARD SO IT IS VISIBLE FROM STREET BUILDING INSPECTION APPROVALS PLUMBING INSPECTION APPROVALS ELECTRICAL INSPECTION APPROVALS F t 2 J 3 HEATING INSPECTION APPROVALS �+ ENGINEERING DEPARTMENT 1 Sv T Ta (t;,We7L, V � OTHER 2 BOARD OF HEALTH VD A-Zi�7/ WORK SHALL NOT PROCEED UNTIL THE INSPEC- PERMIT W;L L BECOME NULL AND VOID IF CONSTRUCTION INSPECTIONS INDICATED ON THIS CARD CAN BE TOR HAS APPROVED THE VARIODUS STAGES OF WORK IS NOT STARTED WITHIN SIX MONTHS OF DATE THE ARRANGED FOR BY TELEPHONE OR WRITTEN CONSTRUCTI[N. I�QI PERMIT IS ISSUED AS NOTED ABOVE. NOTIFICATION. I � , I i I i I Lot 35 Lo T 28 0 L0T.3y m W ap' rr k 4 N � o LOT 2q J i 027 S.F. � _ r 3`1.9 7- LOT 33 -- { LOT 30 CERTIFY THAT- THE l=Q4JND,4T1ON GRE�N�12)ER SHOWN .ON THIS PLAN IS PAUL A. \. CLIENT CD�P, n LEVY JOB NO. 13�Y LOCATED ON THE GROUND �No. lc517 y/, AS INDICATED DR.BY:�4� - �- CHKD.BY.: SHEETLOF�; DATE RE. VEYOR LEVY,ELDREDGE t .WAGNER ASSOCIATES,1K. AS UPL_ PLO P -A ENGINEERS. = LANDSCAPE ARCHITECTS PLANNERS - LAND SURVEYORS 407' a`7 11,ILXORE DRIvE IN 889 WEST MAIN STREET BARNSTA�LE� /�A, CENTERVILLE, MA. 02632 SCALE . 111=yD DATE: 3130181 1 '1P �r Asse�psor's office-'(1st toor)i•— �?� m ff ~ �oFTHE ToAssessor's map and lot numbei .....a , o d♦ Board of Health (3rd floor): s Sewage Permit. number ....... ............ SAMISTAXLE. i Engineering Department (3rd floor) '°o,, NAB \0� House number ....................................^........... ............... r D No d APPLICATIONS PROCESSED 830 9:30 A.M. and 1:00-2 00-'P.M. only' TOWN OF BARNSTABLE BUILDING INSPECTOR APPLICATION FOR PERMIT TO ..........................n/sr ..CT`........ ..w�z..... ....................... . TYPE OF CONSTRUCTION Sn�G c?� n!�tsy. �`'0??�7...... s P .�. • Y ......................................:.........19........ TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: Location I ' • •ftNlr�. p� c � � - ProposedUse ........................... .....:.:. .......... .... ..............:......................................................................... ...... . - ZoningDistrict ........................................................................Fire District .....................................'................................. .......: iZ � /0 �FN rc`/1.,v.� Name of Owner .....l ....... .....L ��.....................Address .. .... '�d . Name of Builder..........Address ....:...�. Name of Arcnitect ` .Address Number of Rooms ..........................:.......................................Foundation .7Uv.Zc� . C'..NeiZCr.'C .. 1 ......................... ............ .. ........ Ex1e for ......... Roofing .... ... �. =A Floors �' ..� .. /U t` TlttlCl. .................:.............................. ............. . ..... ....1'vt/..........................................Interior ........ Heating .... c✓;/d (r/'......................................................Plumbing / rN ............ .......... Fireplace .......... ................................ ..............99..............Approximate Cost .... ......!................................... Definitive Plan Approved - ... by Planning Board ---_--__l_ --______ __19_ Area .! ...s..... .. // . .:........... . Diagram of Lot and Building with Dimensions „Fee . 'Z:. SUBJECT TO APPROVAL OF BOARD OF HEALTH 3a x ay vPs:n:ns I r OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree•to conform to.all the Rules and Regulations of t"wnofnstable regarding the above construction. Name .. :.. . .......:......................... ®o��g7 Construction Supervisor's License ...:......:... ..................... r_ GREENBRIER CORP . ' 32775 BUILD DWELLING M� ....... ... Permit for .................................... ` W Single Family Dwelling ' ` ....... ........................................................... Location ..�.�.. Kilkore...Dr.......(Lot...2.9.�..� ... :Hyannis :............. ...............................................I......... r r Greenbrier Corp . ` Type ofF Construction Wood Frame - r ...................... ; Plot ........:.................... Lot' ........................... Permit Granted . .•Awr.3 l...6.....�.�........19 89 Date of Inspection .............................:......19 s ' 'll► Date Completed 1!E. '' .:.....E.:... -19dir ram, � '� � � { •• - � . . Fes• .. o Assessor's office(1st Floor): Assessor's map and lot number 6 77 Q�OF THE TO�y Beard of Health(3rd floor):Sewage Permit number MUST CONNECT TO TOWN SEWER d� _�,-,��� 11AHl9TAXE. i Engineering Department(3rd floor): �° NAM House number ° +bso• Definitive Plan Approved by Planning Board 19 ,Fo MAI a• APPLICATIONS PROCESSED 8:30-9:30 A.M.and 1:00-2:00 P.M.only TOWN OF BARNSTABLE BUILDING IN PE TOR APPLICATION FOR PERMIT TO TYPE OF CONSTRUCTION - L 19 rJ TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: Location s -- r i Proposed Use Zoning District, Fire District ( 1 Name of Owner Address Name of Builder �'� Address Name of Architect Address Number of Rooms Foundation Exterior Roofing Floors Interior Heating Plumbing Fireplace / Approximate Cost�d®' Area Diagram of Lot and Building with Dimensions Fee,-3y, AV OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINTS I hereby agree to conform to all the Rules and Regulations oqf the Town of Barnstable regarding the above construction. �v h Name Construction Supervisor's License ' BROWN , BOBBI T A=328-104 Y 32755 BUILD SHED I No - Permit For Accessory to Dwelling } 161 Ridgewood Avenue Location. t .Hyannis Owner Bobbi Brown Wood Frame Type of Construction 3. Plot Lot 5.' " Permit Granted Ap r i 1 3 19 8 9 ' Date of Inspection '19 Date Completed Z— �/ 19 Y!" C::� Y � 92 Assessor's map and lot`number �:: Sewage Permit number 'yo*THE ro�y TORN OF ' BARNS TABLE j MARiSTADLE; i # ° "b q :� r R I,LDI1"' INSPECTOR C:S S ✓ 7 7 APPLICATION, FOR ..........................................................+PERMIT TO ............:.. �.� TYPE OF CONSTRUCTION Carr i i .................Y&I..............19.. .. TO THE INSPECTOR OF BUILDINGS: VT The undersigned .hereby applies for a permit according to the following information: Location ...IJ�.I......... LDO!!Q.Qo......Avlv ...................................................................................... .................................... Proposed Use .......LwN(.......( OC?nn ZoningDistrict ................................. ....................Fire District .............. ....... ............................................. p J Name of Owner .�1S21f! !aS..... .. .... ?. 4.4!�h�...............Address I.61......... .........,�/� Nameof Builder .......,.SAPAC.................................................Address .................................................................:.................. Nameof Architect .....,$IF.IM9................................................Address .................................................................................... Number of Rooms ..........I.........:............................................Foundation ....POA). _kQ..........Coh).G.Refit............................ Exterior ........ ........0.4.......LOMPARA(ILi:7 ......................Roofing .......ffi%AO.......-. . Floors ......C 9.r..................... ......................................Interior ......... ELT RAC Heating ......NJA......................................................................Plumbing ......A?lA........................:............................................... Fireplace ..........J. .A..................................................................Approximate Cost .......5.,, PQ................................................. Definitive Plan Approved by Planning Board ________________________________19--------, Area .......... Diagram of Lot and Building with Dimensions Fee .. .....�..:..5:......................... SUBJECT TO APPROVAL OF BOARD OF HEALTH �34. a0 00 A —� t �8, j f f / -4- rd C Q i6' Fx�ST�u6 N5 .3 T Q 4' FuD. 93 a ' • . R\OC�EWWO MUE I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. /�� Name4,%�.. <4m ... ............. Brown, Thomas E. No ..189.96.... Permit-for ...addi.tim............... ......single-family..dwalling.....................:.. Location 1b.1Ridgewoo,d..AQemue...................... .; .. ......Hyannis....................................................... Owner ....Thomas...Ee..hxown.. .......................... �r Type of Construction ..wood-frame................ �- r....................................................... `✓ i F� f .Plot ............................ Lot ................................. -- � I Permit Granted ..........Marsh8.............................:1977 L ^1 .^ 'Date of Inspection ...... .... ....19 - Date Completed ...... ...........�19 'PERMIT.REFUSED" ..................................... .. ....... n.... 19 ................... ....................................................... ILA • • ....................#.... ......... .......... ••••,••••••,•••••,••• ' + 4 r • • • - ...................................................................... . ..f , i� • A • �� }• _ ' "• • III ................................................ ......................... ' +¢ . �•l Approved y r .............. ............................................................................... ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT _ Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH Zg THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR : - AHJ: Barnstable . _ REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: NSTAR Electric (Commonwealth Electric) • ' dp CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-0 261363 00 PREMISE OVAER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE MOREIRA, REGINA MOREIRA RESIDENCE Mikhail Gofman BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: wo„SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 161 RIDGEWOOD AVE 7.42 KW PV ARRAY PART OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION VATH MODULEs: BARNSTABLE, MA 02601 TMK OWNER:* 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) Hanwha Q—Cells #Q.PRO G4/SC 265 AMN. * SHEET: REV: DATE: Marlborough, MA 01752 SOLARCITY EOUIPMENT, WITHOUT THE WRITTEN PAGE NAME: T: (650)638-1028 F: (650) 638-1029 PERMISSION OF SOLARCITY INC. INVERTER: � SOLAREDGE SE6000A-USOOOSNR2 (508 221-4848 COVER SHEET PV 1 6/30/2015 (688)-soL-CITY(765-2469) wwwsdarcity.com PITCH: 30 ARRAY PITCH:30 n MP1 AZIMUTH: 101 ARRAY AZIMUTH: 101 OF Mqs MATERIAL:Comp Shingle STORY: 2 Stories ozs```p S�oyG PITCH: 30 ARRAY PITCH:30 HUMP Y K. N MP2 AZIMUTH:285 ARRAY AZIMUTH:285 o KARIUKI MATERIAL: Comp Shingle STORY: 2 Stories STRUCTURAL PITCH: 30 ARRAY PITCH:30 NO.51933 ° MP3 AZIMUTH: 101 ARRAY AZIMUTH: 101 �GISTER �� MATERIAL: Comp Shingle STORY: 2 Stories SS/ONAL ENG STAMPED & SIGNED FOR STRUCTURAL ONLY B Digitally signed by Humphrey Kariuki Zd W Date:2015.06.30 04:34:23 04'00' LEGEND Q (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO O \ & WARNING LABELS - I © DC DISCONNECT & WARNING LABELS AC AC , �_ P3 AC 0 - AC DISCONNECT & WARNING LABELS Inv ©� DC JUNCTION/COMBINER BOX & LABELS C DISTRIBUTION PANEL & LABELS Lc LOAD CENTER &WARNING LABELS A (E) DRIVEWAY O DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR 161 Ridgewood Ave GAA�uFENCE ON INTERIOR Front Of House O HEAT PRODUCING VENTS ARE RED r,_-i It 'i INTERIOR EQUIPMENT IS DASHED L-'J SITE PLAN Scale: 1/8" = 1' z 0 1' 8' 16' m J B-0261363 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: �\`!a CONTAINED SHALL NOT BE USED FOR THE MOREIRA REGINA MOREIRA RESIDENCE Mikhail Gofman �;,,SO�a�C��ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 0.0, r® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 161 RIDGEWOOD AVE 7.42 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES BARNSTABLE MA 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) Hanwho Q—Cells #Q.PRO G4/SC 265 SHEET: REV: DATE Marlborough,MA 01752 SOLARCnY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T. (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A-US0005NR2 (508) 221-4848 SITE PLAN PV 2 • 6/30/2015 (888)-SOL-CITY(765-2489) vww.saIarcRy.c f OF Mgs11O HUMPHREY K. N O KARIUKI S U STRUCTURAL to S 1 NO.51933 SFG/STERN `s/ONAI EN . 4„ STAMPED & SIGNED 10'-11" olFOR STRUCTURAL ONLY 6 (E) LBW 6 (E) LBW SIDE VIEW OF MP1 NTS - SIDE VIEW OF MP2 NTS A 6 MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 721.1 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 17" PORTRAIT 48" 17" ROOF AZI 101 PITCH 30 ROOF AZI 285 PITCH 30 RAFTER 2x6 @ 24" OC ARRAY AZI 101 PITCH 30 STORIES: 2 RAFTER 2x6 @ 24" OC ARRAY AZI 285 PITCH 30 STORIES: 2 C.J. 2x6 24" OC C.J. 2x6 @24" OC Comp Shingle @ Comp Shingle p g P 9 PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE SI (E) 1x8 ZEP LEVELING FOOT E LOCATION, AND DRILL PILOT r ZEP ARRAY SKIRT (6) HOLE. (4) C(2)FSEAL PILOT HOLE WITH OLYURETHANE SEALANT. 4" ZEP COMP MOUNT C 7'-1" 0" ZEP FLASHING C (3) (3) INSERT FLASHING. 6 (E) LBW (E) COMP. SHINGLE (1) (4) PLACE MOUNT. SIDE VIEW OF MP3 NTS (E) ROOF DECKING (5) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS O (5) SEALING WASHER. STEEL LAG BOLT LOWEST'MODULE SUBSEQUENT MODULES MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES WITH SEALING WASHER (6) INSTALL LEVELING FOOT WITH LANDSCAPE 64' 24" STAGGERED . n BOLT & WASHERS. (2-1/2 EMBED, MIN) PORTRAIT 48" 17" RAFTER 2x6 @ 16"OC ROOF AZI 101 PITCH 30 STORIES: 2 (E) RAFTER ARRAYAZI 101 PITCH 30 .7TANDOFF C.J. 2x6 @16" OC Comp Shingle Scale: 1 1/2 — 1 J B-0 2 613 6 3 O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HERON JOB NUMBER: \\ MOREIRA, REGINA MOREIRA RESIDENCE ,,,SolarCity. CNTAINED SHALL NOT BE USED FOR THE Mikhail Gofmon �� ? BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 161 RIDGEWOOD AVE 7.42 KW PV ARRAY PART TO OTHERS ORGANIZATION, EXCEPTTIIIN ONNECTION WIITH MODULES: BARNSTABLE, MA 02601 THE SALE AND USE OF THE RESPECTIVE 28 Hanwho Q—Cells .PRO G4 SC 265 2a sL Martin Drive,Building 2 Unit 1t ( ) / PAGE NAME: SHEET: REV: DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT WITHOUT THE WRITTEN _ _ PERMISSION OF SOLARCITY INC. INVERTER: 508 221-4848 PV 3 6 30 2015 T: (sso)ITY 1029 F. (s50)638 1029 d� SOLAREDGE SE6000A—USOOOSNR2 ) STRUCTURAL VIEWS / / (t1eB)-sa-CITY(7s5-24Bs) wwwsolarcity.cam GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:A00795HOl Inv 1: DC Ungrounded INV I -(1)SOLAREDGE #SE6000A-USOOOSNR? LABEL: A (28)Hanwha Q-Cells #Q.PRO G4/SC 265 GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:43995345 Tie-In: Supply Side Connection Inverter; 6000W, 240V, 97.574 w Unifed Disco and ZB,RGM,AFCI PV Module; 265W, 241.3W RTC, 40mm, Blk Frame, MC4, ZEP, 600V ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 38.01 Vpmax: 30.75 , INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 100A MAIN SERVICE PANEL E; 10OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER-HAMMER Disconnect CUTLER-HAMMER 1 _ _ 10OA/2P 4 Disconnect 3 SOLAREDGE DC+ A 35A SE6000A-USOOOSNR2 DC- MP 2/3: 1x16 B -- EGC I -------- ---------- I B L2 - DC, N DC- 1 2 I (E) LOADS GND _ ____ GND _-___ EGC/ DC+ + - 1 _ -------------------- ^ GEC --TN CC MP 1: 1x12 . r---J -- -- -------------- --- ---- �~ DG- FIGND EGC G ----------------- tJ N I (I)Conduit Kit; 3/4' EMT 1 _j EGCLEC I I L_ GEC TO 120/240V SINGLE PHASE I I UTILITY SERVICE I I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (2)Ground Rod; 5/8' x 8'. Copper A (i)CU•TLER-HAMMER $OG222NRB /� PV (28)SOLAREDGE /�300-2NA4AZS D� -(2)ILSCO f IPC 4/0-#6 Disconnect; 60A, 24OVac, Fusible, NEMA 3R A PowerBox ooptimizer, 300w, H4, DC to DC, ZEP Insula ion Piercing Connector, Main 4/0-4, Tap 6-14 -(1)CUTLER- AMMER I DG100N8 (1)AWG#6, Solid Bare Copper SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE CUTLER �AMMEl Kit; 60-100A, General Duty(DG) nd S -(I) R-HAMMER $DS16FK -(1)Ground Rod; 5/8' x 8', Copper AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Class R Fuse Kit -(2)FERRAZ SHAWMUT#TR35R PV BACKFEED OCP . (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO, 2, ADDITIONAL Fuse; 35A, 250V. Class RKS B (1)CUTLER-HAMMER #DG222UR8 ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE Disconnect; 60A, 24OVac, Non-Fusible, NEMA 31? -(1)Grnou dj eutral KitD60 OOA, General Duty(DG) 1 AWG#6, THWN-2, Black 1 AWG #8, THWN-2, Black (2 AWG#10. PV Wire, 60OV, Black Voc* =500 VDC Isc=15 ADC ® (1)AWG#6, THWN-2, Red O L'L(1)AWG #8, THWN-2, Red O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=11.96 ADC (1)AWG #6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (j)Conduit Kit;.3/4'.EMj . . . . . . .. . . -(1)AWG #G,.Solid Bare.Copper. GEC. . _ . (1)Conduit.Kit;.3/4'.EMT. .. . . . . . . . . . . . .. .-(1)AWG #8,.THWN-2,.Green . : EGC/GEC.-(1)Canduit.Kit;.3/47-EMT_ _ - . . _ . . . . ( )AWG#10. PV Wire, 60OV, Black Voc* =500 VDC ISC =15 ADC O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.97 ADC . , . . . . , (1)Conduit Kit;.3/4'.EMT . . . . . . . . . . . . .. . . . . . . . . .. . . . . .. . . . . . ... . . J B-0 2 613 6 3 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: \=��a CONTAINED SHALL NOT BE USED FOR THE MOREIRA, REGINA MOREIRA RESIDENCE Mikhail Gofman �,;SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'W" NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 161 RIDGEWOOD AVE 7.42 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: BARNSTABLE, MA 02601 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) Hanwha Q-Cells #Q.PRO G4/SC 265 SHEET: REV: DAIS Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME T. (650)638-1028. F. (650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER" SOLAREDGE SE6000A-USOOOSNR2 (508) 221-4848 THREE LINE DIAGRAM PV 4 s/3o/20�5 (666)-SDL-pTY(765-2489) www.�larcltycm • • e o •e - • - Label Location: Label Location: Label Location: (C)(CB) o (AC)(POI) 1 0 (DC) (INV) Per Code: _ _ Per Code: _ e e o- •o• �_ Per Code: NEC 690.31.G.3 �o ° o ° • • NEC 690.17.E I o NEC 690.35(F) Label Location: o :o - ° - o 0 0 TO BE USED WHEN O O O C D (DC)(INV) °•e o-• --o o P •e_o D D • IS INVERTER IS D O Per Code: UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: - o 0 0 0• -o �� (POI) • -o - (DC)(INV) o Per Code: Per Code: • • -. eo 0 o NEC 690.17.4; NEC 690.54 ° V NEC 690.53 • :o a o•° s • e o- ° • III -o a e- o- Label Location: `i0 rl o (DC) (INV) Per Code: �• NEC 690.5(C) -o a ® • a o o- -o e °• Label Location: o . Ip (POI) o e • e Per Code: NEC 690.64.B.4 Label Location: o (DC) (CB) o ,-e ' Per Code: Label Location: s e e e NEC 690.17(4) Q (D)(POI) . o•e a -•• a - o 0 0 Per Code: ° ®;. a NEC 690.64.13.4 Xi EAM{{ o •- o■ Label Location: (POI) Per Code: Label Location: ° - ° °- NEC 690.64.B.7 p O O O ( (AC)(POI) e o o - o (AC): AC Disconnect D O� Per Code: °° - (C): Conduit NEC 690.14.C.2 (CB): Combiner Box _ (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect 0 (AC)(POI) (LC): Load Center •' Lam-" Per Code: NEC 690.54 (M): Utility Meter T (POI): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED MALL NOT BE USED FOR `�%It,j 3055 Clearview way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set ��••►►` T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I� Solarcity. (888)-SOLLITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. Next-Level PV Mounting Technology ^SolarCity ZepSolar.. Next-Level PV Mounting Technology SolarCity I ZepSolar Zep_System Components for composition shingle roofs 1 - A � `"4:..1U' roof - --- -. - • '- - 6reura Interlockl Zep . Leveling Font' a - Zcp Currrpatlblo W Modalc i- - Roof Atmehmeot - Array Skfrt - QGOMPgT/ ea,� Description W PV mounting solution for composition shingle roofs ��CeMPpt�w • Works with all Zep Compatible Modules ±v • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules Auto bonding UL-listed hardware creates structual and electrical bond U� LISTED Comp Mount Interlock Leveling Foot Part No.850-1345 Part No.850-1388 Part No.850-1397 Listed to UL 2582, Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 Designed for pitched roofs Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • r UL listed to UL 2703 and ETL listed to UL 467 Zep System grounding products are P Y 9 9P • Zep System bonding products are UL listed to UL 2703 • 7 "and cantilevers u to 24" Engineered for spans up to 2 p • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467' 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for - each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com.- responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 1 of 2 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 2 of 2 solar=oo solar=oo SolarEdge Power Optimizer Module Add-On for North America p P300 / P350 / P400 SolarEdge Power Optimizer Module Add-On For North America Q P300 P35072— P400 (for modules) PV (for modules) PV (for modules) PV modules) modules) modules) . .. .. - .. P300 / P350 / P400 INPUT,, Rated Inpu[DC Power'o 300 350 400 W Absolute Maximum Inpu[Voltage(Voc at lowest temperature) 48 60 80- Vdc MPPT Operating Range ..............8._48.....................8..60.............. 8-80 Vdc Maximum Short Circuit Current(Isc) 30 Adc , Maximum DC Input Current 12.5 Adc :........ ........ ... .... ..... ............. ... ... ....... ... - Maximum Efficency 99.5 % ......... .. .... ..... .. .......... ..... .. ... .... .. ,X'{- - Weighted Efficiency 98.8 % - ... .......... .. . .... .... ... ......... ..... .. .. ... .. Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) I Maximum Output Curren[ .............................15....... .......................... ...Adc ��--11 Maximum Output Voltage 60 Vdc IpL OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF). . r--,� Safety Output Voltage per Power Optimizer 1 Vdc r STANDARD COMPLIANCE .. s •� EMC FCC Part15 Class 8 IEC63000 6 2 IEC61000 6 3 `�• Safety IEC62109 1(class II safety),.UL3741 ... ... ......... ......... ..... ......:. .. ... .... .... .......... RoHS Yes - - _ INSTALLATION SPECIFICATIONS - - ,es Maximum Allowed System Voltage 1000 Vdc f Dim eions(WxxH) 141x212x4055 SS 834x 159 mm/m ' Weight(including cables) 950/2.1 gr/lb ., a. Inpu[Connector ... MC4/Amphenol/Tyco.... ................. ... Output Wire Type/Connector .. Double Insulated;Amphenol Output Wire Length 0.95/30 I .. ... .......... ........ ... .... ... Operating Temperature Range :40-+85/40 +185 •C/•F„ ... ...... .......... .. .. ..... .... ... Protection Rating IP65/NEMA4 ......................Y....................-.............................................................. .... ........ .. ... ................................ Relative Humidit .................................... .:.100.............................._. ...... aamo s*cpo.e.ormo moawe.Moaw.orwro sx pow..mm�o�re,nowea. �PV SYSTEM,DESIGN USING A SO_LAREDGE THREE PHASE THREE.PHASE -INVERTER SINGLE PHASE 208V 480V PV power optimization at the module-level Minimum Strip Length PowerOptimizers 8........................10.........................18......................... 25 Up to 25%more energy - - Maximum String Length(Power Opdmuers) 25 50 Maximum Power per String 5250 6000 12750 W -.Superior efficiency(99.5%) -. ... pe.. ................. ... ... ........ .. .. ..... ..... ........ .... .... Parallel Strings of Different Lengths or Orientations Yes — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading "' "" """"' """""""."'""' ..'......."""""' """"' "' """"""""'.............. — Flexible system design for maximum space utilization - y — Fast installation with a single bolt - Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA Www.solaredge.us - - - �r..+`m�-- ++e++a•o+w.vwuaesravte�.m. .. v�rnno�.��rr JS - solar=oo Single Phase Inverters for North America solar v SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE10000A-US/SE1140OA-US SE3000A-US SE380OA-US I SESOOOA-US I SE6000A-US I SE7600A-US I SE10000A-US I SE1140OA-US OUTPUT 9980 @ 208V SolarEdge Single Phase Inverters Nominal AC Power Output 3000 3800 5000 6000 7600 10000 @240V 11400 VA ....... ............ .............. ....... ........... ... ............ .............. ...... ......... . .................. .. ...... 5400 @ 208V 10800 @ 208V • Max.AC Power Output 3300 4150 6000 8350 12000 VA For North America 5450@24DV 1D95D@240V .............. ......... AC Output-Voltage Min:Nome Max.' 183-208-229 Vac SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ .Outp.tVol.......n.-N .....:...... ................ ............... ................. ................ ................ .................. ..... AC Output Voltage Min:Nom.Max.' � � � � � ��` V SE760OA-US/SE1000OA-US/SE1140OA-US 211 240 264Vac AC Frequency Min..Nom.Max.'..•.. ............•• 59.3 60 60.5(with HI country setting 57 60 60.5).. .. . ... ........... ......... ..... ..... ............ .. .. .. p za @ zo8v 48 @ zoav Max.Continuous Output Current •••• 125 ....� 16.. •1••21.@.240V.. ......2..•••••• ••.. 3.. ......... V•_• . ..••47.5 A i GFDI 1 A Utility Monitoring,Islanding Protection,Country Configurable Yes �werte� ThresholdsX INPUT els _ - Recommended Max.DC Power— le3750 4750 6250 7500 9500 12400 14250 W W1T8n� • .(STC) ............... ...... ........ .. .......... .................. ................ ......... .................... ..... ......... ................ ............... .. .. Tra f. nsformer-less Un rounded Yes Max.Input Voltage 500 Vdc __ •�. Nom:DC Input Voltage 325 @ 208V/350 @ 240V Vdc ........... .......... .. ...... ..... .. r. Max Input Current'• 9.5 13 8 18 23 2 0 34.1 Adc < . .................... ... .......... ..............:1...............1..15:5.@.240V. .. 20 33 @ 8V pp 30.5( 4 V .r Max.Input Short Circuit Current 30 •• 45 Adc Reverse Polarit......Protection.......... ................. ........ .............. ......:Yes........ ........................ ................. Protectio. .. .. .... Ground Fault Isolation Detection 600ko Sensitivity I ........................................... ................ ............... ................. ................................ .................. .................. ........... Maximum Inverter Efficiency.. ...... ... .97: ...... .....98:Z..... ......98:3..... .....98:3...... ......95...... 98........ ..... .98... ...- ....%..... 97.5 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.5 97.5 .. - .................. 98 @ 240V.. .... . ... .......... ..975..24... ................ .. ... ....... ..... ..... .. ... .... .. ..... .. ... .......... .. .. .. .. Nighttime Power Consumption <2.5 <4 W .. ,. :._. ADDITIONAL FEATURES,:. Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) ... even........... ...................... ............................... ..... . .......... ... ..... . ...... ........... .................. .. ......... Revenue Grade Data,ANSI C12.1 Optional e - STANDARD COMPLIANCE Safety t UL1741,UL16998,UL1998,CSA 22.2 Grid Connection Standards IEEE15 class s .• •.•..............• .•..•••• ., ........o ...... ............ a 15 class B - '- Emissions FCC rt INSTALLATION SPECIFICATIONS, output conduit size/AWG range .3/4 minimum/24 6 AWG 3/4"minimum/8 3 AWG „ DC input conduit size/#of strings/ y d r 3/4"minimum/1 2 strings/24 6 AWG 3/4"minimum/1 2 strings/14-6 AWG 3 AWG range............................. Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ in 30.5 x 12.5 x 10.5/775 x 315 x 260 / �,.. .. _.,•. _'�' Switch(HxWxD)............. .......... .......775 x 315 x 172........ ........775 x 315 x 191......... ...................................................... ... m!^.... _•, _-,,_-. _..., ,,, - _ Weight with AC/DC Safety Switch 51 2/23.2 54 7/24 7 88.4/40:1 ...•••.••. lb/•kg... ........................ ................................ .................................. ........... ..... ....... .............. Cooling Natural Convection Fans(user replaceable) ..................................... ...... ........................ . .. . .. .. The best choice for"SolarEd a enabled systems Noise ... .... ........<zs... ........................... .. ..... ......<so.................... :dsA... g y _ Min.Max.Operating Temperature . - .� .. 13 to+140/ 25 to+60(CAN version****-40 to+60) •F/•C �. Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance Range ................. ....................................... ...... ....... .................................................. ................ ........... . Protection Rating ................................................•......NEMA3R _ Superior efficiency(98%) ease coma ' •For Other regional settings please contact SolarEdge support Small,lightweight and easy to install on,provided bracket Limited to 125%for locations where the yearly average high temperature sabove 77•F/25-C and to 135%for locations where it is below 77'F/25'C. l , For detailed information,refer to x 11 Built-in module-level monitoring •'A higher current source may be used;the inverter will limit its input current to the values stated. 1 •'CAN P/Ns are eligible for the Onta no FIT and m icmFIT(microF IT exc.SE 11400A-US-CAN). Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only Pre-assembled AC/DC Safety Switch for faster installation Optional—revenue rade data,ANSI C12.1 yy� „•err— 0 P g �unsr�c I USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THENETHERLANDS-ISRAEL www,SOlaredge.uS •'"°*'a l _ I• I y - SPECIFICATION Format 65.7 in x 39.4in x 1.57 in(including frame) (1670 mm x 1000 mm x 40 mm) Weight 44.09 lb(20.0 kg) •• •n .°.,..�..°�, r>t - front Cover 0.13 in(3.2 mm)thermally pre-stressed glass 'with anti-reflection technology Back Cover Composite film ��� �� <•.i•mm j, Frame Black anodized 7FP compatible frame Cell 6 x 10 polycrystalline solar cells - -- J ]unction box Protection class IP67,with bypass diodes --"�~ Cable 4 mma Solar cable;(+)a47.24 in(1200 mm),(-)a47.24in(1200 mm) - - - Connector MC4 UP 68)or H4 UP68)ELECTRICAC CHARACTERISTICS �'��� u••M I' Imo'"'"'" ° 9 • • , ,I ` PERFORMANCE AT STANDARD TEST CONDITIONS(STC:1000 W/m',25•C,AM 1.5G SPECTRUM)' - _POWER CLASS(+5 W/-0 W) IW l 255 260 265 Nominal Power P_ I]Nl 255 260 265 • , • L ' ' is a in Short Circuit Current Is, [A] 9.07 9.15 9.23 Open circuit Voltage Vnc IV] 37.54 37.77 38.01 Current at Pro, - I1°r° [A] � 8.45 8.53 8.62 Voltage at P_ V„r°, IV] 30.18 30.46 30.75 The new Q.PRO-G4/SC is the reliable evergreen for all applications, with -- Efficiency(Nominal Power) , [%1 a15.3 a15.6 a15.9 a black Zep Compatible"M frame design for improved aesthetics, opts- PERFORMANCE AT NORMAL OPERATING CELL TEMPERATURE(NOCT:800 W/mx,45 x3"C.AM 1.5 G SPECTRUM)' UI POWER CLASS IW] 255 260 265 mized material usage and increased safety.The 4 solar module genera- _ _ 95.7 tion from Q CELLS has been optimised across the board:improved output ShoNomrt Circuit Power P„e, (A] 17.31 19EA 17.44 Short Circuit Current Ise [A] 7.31 7.38 7.44 yield, higher operating reliability and durability, quicker installation and open circuit Voltage V. IVl 34.95 35.16 35.38 more intelligent design. Current at PMp 1- LA] 6.61 6.68 6.75 Voltage at Pw" V_ IV] _ 28.48 28.75 29.01 'Measurement tolerances STC:--3%(Pm°°);x 10%0I,Vs,Imp,v_) Measurement tolerances NOCT.:5%(Pm°°);se 10%(h,.Vim,Imp,V�) INNOVATIVE ALL-WEATHER TECHNOLOGY PROFIT-INCREASING GLASS TECHNOLOGY Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE •Maximum yields with excellent low-light •Reduction of light reflection by 50%, �%'m � At least 97%of nominal power during • i,.e°,ffiw.a "....,,."°e first year.Thereafter max.0.6%de ra and temperature behaviour. plus long-term corrosion resistance dues """"'""" " Y p g ___ da[ion per Year. z ' •Certified fully resistant to level 5 salt fog to high-quality At least 92%of nominal power after a •Sol-Gel roller coatingprocessing. _ 10 years. E p g• _ At least 83%of nominal power after -- ENDURING HIGH PERFORMANCE W C 25 years. d _ _ •Long-term Yield Security due to Anti EXTENDED WARRANTIES r: All data within measurement tolerances. se Full warranties in accordance with the PID Technology',Hot-Spot Protect, •Investment secunty.dueto12-year wam arty terms of the 0 CELLS sales IRRADIANCE11M.9 organisation of your respective country. and Traceable Quality Tra.QP°" irradiance of 200 W/m2 in relation n to 1000 W/ma(both at 25°C and AM 1.5G spectrum)is-2%(relative) •-Long-term stability due to VDE Quality, performance warranty-. �'°�°""'�"-'�"`°"`°"' � Tested-the Strictest test program. TEMPERATURE COEFFICIENTS(AT 1000W/M2,25°C,AM 1,50 SPECTRUM) - •QCEEES Temperature Coefficient of Iu a [%/Kl +0.04 Temperature Coefficient of V. 9 [%/K] -0.30 a _ m aurtm c SAFE ELECTRONICS TOP BRAND.PV Temperature Coefficient of P_ y [%/K] -0.41 NOCT ['F] 113 x 5.4(45 t 3-C) •Protection against short circuits and PROPERTIES FOR ' thermally induced power losses due to 2014 Maximum System voltage V°„ IV] 1000(1 EC)/600(UL) Safety Class II breathable junction box and welded Maximum Series Fuse Rating [A DCl 20 Fire Rating C/TYPE 1 e cables. - - Max Load(ULF [Ibs/R'1 50(2400 Pa) Permitted module temperature -40°F up to+185°F on continuous duty (-40°C up to+85°C) rfjC Phs f.. _ Load Rating(ULF [lbs/ft21 50(2400 Pa) 'see installation manual S Quality Tactod QOEL,LS . • BEd R°tNlsrAnhiE ' , • •, ' EDUr mo0iU x013' UL 1703;VDE Quality Tested;CE-compliant; Number of Modules per Pallet 25 °°'•�"a IEC 61215(Ed.2);IEC 61730(Ed.l)application class A THE IDEAL SOLUTION_ FOR' t0.4Q0375a7 �••,°. Number of Pallets per 53'Container 32 - e1°R _ e Na`' m� Number at Pallets per 40'Container 26 _ Rooftop arrays on SPm ®residential buildings GpMPq>iA _ r D E C E cGUs - / Pallet Dimensions(L x W x H)_ 68.5 in x 44,5in x 46.0 in ti Cf""• '�zooO• (1740 x 1130 x 1170 mm) Pallet Weight 1254lb(569 kg) ` ' APT test conditions:Cells at•1000V against rounded,with conductive metal foil covered module surface. ~t"o 0 NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of g R CQMPp•P this product.Warranty void if non-ZEP-certified hardware is attached to groove in module frame. 25°C,]68h R See data sheet on rear for further information. Hanwho Q CELLS USA Corp. 8001 Irvine Center Drive,suite 1250,Irvine CA 92618,USA I TEL+l 949 748 59 96 1 EMAIL gcells-usa®q-cells.com I WEB www.q-cells.us Engineered in Germany CM CELLS µEngineered in Germany G ICELLS y - t t�y t � � CONTINUOUS RIDGE VENT ""--- ---- ' IXS A'LEX TRIM RIP Iz8, IxB AZEK RAKE TRIM- - AS REQUIRED AN I4 S?4x WINDOWS T SHOWN •L FLASHING;BASE RA STRIP WITH 5/4%4 AZEK TRIM L COLONIALS'•,. ICE AND SNOW WRAP UNDER -- N SILL PACKAGE FROM MILLWORK _ - TRIM TO TOP ROOF AND OVER --- O SUPPLIER �------ FELT LOW ROOF,b"LEAD OVER '--� �� STAIRS RISERS<-7";TREADS X II"MIN., N RISER ._......___-.___._-._.... —_ m 1 - 11-u I u I, - - - - - STAIR FINISH NOTES: 14--'{ 1)UPPER RAIL MOLDED CEDAR 2.4 \� 1 (71 1, 2)LOWER RAIL 2x4 CEDAR _ 3)PICKETS FULL 1 1/2'SO CEDAR `, I, --- WINDOWS 5410WN AS ANDERSON W/ AZEK TRIM @DOOR'---- OR P.T.SPACED C-4"BETWEEN -I'l� Ix4 AZEK TRIM♦SILL PACKAGE Z Ix5�L AZEK CORNER-- _..1-FFT 4)TREADS 2x OR 1 1/4"P.T.STOCK H ® ® ® ® 5)RISERS Ix P.T.OR CEDAR ® I till, ® I' J •'�I b)HANDRAIL BOTIi SIDES Ln a `I 7)DECK FRAMING 2x OR 11/4"P.T. Z a s STOCK O Y Y Y Y B)POST 4x OR 6x PER PLAN NOTES iI V�o u v I I I II Li 0 Q Z I I I II F ___ I om n w y I 1 I 1 i u ___________________________�_I z W < O FRONT ELEVATION LEFT ELEVATION o W SCALE: 1/4`-V-0" SCALE: 1/4"-V-0' 0 z O o z � z O O LI L1 W j U W IX AZEX TRIM RIP -AS REQUIRED --_.......,_.\ FLASHING;BASE 18'STRIP IC.' AND SNOW WRAP UNDER �— TPIM TO TUP RGbF AND OVER. F,.t_T LOW ROOF.b" LEAD OVER RAIL CLEARANCE MINIMUM; IF WINDOW CHO"'EN LAPS RAIL STAND OFF POST TO SILL AND BLOCK/BOLT TO WALL -._ r V / It i z - I I /y1 11 lilt if I I I 1 1 I I li -iI o I I it 111 1,II I I 00 li W Q _______ _ _ _y __ r------ ---- - ----------- ----- > �— r---------------------------------------------- �— U) W B'-3 I/2" 15'-9 I/2" LEIR-p^ 1� j j I y I I W 1 -------------------------------- 1 f�______________ (2) 8"55D SONG TUBES I I I I ---1�-- r'-J----------------------------- --------- -'� L------------ AT BACK EDGE L-------------------------------------------� REAR ELEVATION RIG--IT ELEVATIONAl SCALE: 1/4"-1'-0" �. :SCALE: 1/4".=I'-O" NOTE.PALN SET 15 TWO DRAWING Al A2 1 STPIR NOTE: I)TREADS 2,12 P.T., 4 2) (3FO)I USE 2x12 5T I 6 K/ N - 3 USE M P05T 6 W/x6 SIMPSO AC TOP AND AB66 BASES. 4>• I 4)STAIR POST 4x4 P,T.W/SIMPSON AC TOP, 26-0' 6 AB44 BASES - 26'-0' IR DESIGN HEIGHT 6 J DOOR, ISR STAIR» CONCRETE PAD;IB' /- - - _ .. _ / IR CONCRETE 9 FLOOR(7" R MAX)_3 1 1 _I B-6 1/4 HAUNCH IS BOTTOM IO GRADE TO SUB F __- 13 I/2 / _. - / _ _-- / TREAD / 12 IO 3/4" 114T®11 .3"] / .. / .... 5,-li/ (2)d° SONOTIiBE 6 vY .... _ O%7 FRM _ TO 4 ._ _.. .,. 3' O 10- 50.0 TUBES TO }AB GRA �I l i 1_. SLAB 6RADE� m I i HOLD U DWGRADE- FOR POST Ba(O-7") l 1 1 l II I >-(0-7") j I I 3'-6 1/2° I I 0 6 - - - WALL GRADE-(0-0') n O 9'-4°... , SLAB GRADE-(0-6°) Ln i <D OP ^/ N 0 A2 J X OILL. m bI '/tom' pun is 1 _, u a � in� �-�--F a �W �99 j3 30x30x14'FOOTING W/ I OZ Z (4)a5 REBAR E W.3- U p a 1 ... \\ �•jj, FROM --\\3- WALL GRADE-(O-O° t. BOTTOM ... —_.. )) �.1 3/LGTB _\ TOP DROPPED FOUNDATION -(0-II') m= Nd'�N� e s! omnwo WALL GRADE-((O-O') _ SLAB GRADE-(O-q') p TOP DROPPED FOUNDATION -(1-3 °9 1 ..-_�.-..-.._. 7D—OWN APRON SLOPE ku A�, APRON SLOPE DOWN 33'1 GROUND G DRIVE 3-(0-12') 6 < > d 2,_q. 9'_0" 2,�. q�_p° 2-q" Q U NY w a FIRST FLOOR FLAK! SECOND FLOOR PLAN FOUNDATION PLAN SCALE: I/4'-1'-0" SCALE: 1/4"-1'-0" SCALE: 1/4"-I'-0° 6 Z O a In CONTINUOUS RIDGE VENT "' N O 2 x 12 RIDGE --""--_-"" - TYPICAL ROOF CON5TRUCTION. Ln 1x6 HANGER®I6'O.C_- ARCH,GRADE ASPHALT ROOF SHINGLES, _x 12 RIDGE" W 5 15 L.B.FELT PAPER, 5/6 'CDX PLYWOOD W/"H'CLIPS W 2x4 CONTINUOUS, TIE SHEATHING/2 x 0'5 P 16'O.C. 0_ TO GABLES ""' \ 12 NOTE9: 2.4.30-BLOCKING �6 1)GRADE ELEVATIONS GIVEN FOR REFERENCE, SITE TO GOVERN \\ FIELD VERIFY.MINIMUM GRADE TO TOP FOUNDATION B', ALLOW SIMP50N 2.5 CLIP, \ \ FOR SLOPED APRON AT OVERHEAD DOORS, PROVIDE STEP 9 EACW RAFTER --'-- SIDE EXTERIOR DOOR IF REQUIRED. 2)REAR STAIR VERIFY TOTAL RISE AND ADJUST RISERS AS Ix2, ON FASCIA(RIPPED) REQUIRED 50 MAXIMUM RISE IS 7. W/CONTINUOUS VENTING 3)SECOND LEVEL JOIST MI q 1/2"V 16-O.C.TYPE PER MANUFACTURE.4)LVL SHOWN AS(1)1 3/4'x 14" LVL IB TO 2 x 6 NAILER CONTINUOUS"' BE VERIFIED BY SUPPLIER BASED ON A DECK LIVE DAD OF 6 400/SF, DEAD DAD OF 150 PER SF, NOTE BEARING WALL 2 x 4 0 16'O.G. -'- 12 LOCATED G 3'-4'. 5)BIRCWALL CONSULTING WAS BASED ALL DESIGN ON KNOWN C LOCAL CODES AND BEST ENGINEERING PRACTICES BUT C A55UMES NO RESPONSIBILITY FOR ERRORS OR OMISSIONS. _q. TYPICAL P AL 35UBCFDLXOOR,G 3'-4 TYPICAL 3/4"CDX T t 4 PLYWOOD SUB FLCOR Z V 1 ' ^ Q Z GLUED 4 NAILED ._.._._. _. GLUED 4 N NAILED v J O --(3)1 3/4A4 LVL L GARAGE Q N 2.b MID T. OF ALL U P WALLL TYP. OF ALL EXTERIOR WLIS _ T ILL- 2 1/2'COX PLYWOOD SHEATHING ' —+— - x 6 SHOE , 2 x b SHOE O ---2 x B TREATED BILL _ Q 2•B TREATED SILL O \ Z P"- -J N Q -. 4'CONCRETE 5LA13 ON 6'CRUSHED STONE AND 4'CONCRETE SLAB ON \ - � Z 6 MIL, POLY VAPOR BARRIER 6"CRUSHED STONE AND _S� 6 MIL.POLY VAPOR BARRIER / 1/' �/� ��/ ( , o 7 i SECTION SECTION H7 5C4LE:1/4•' -I'_p" SCALE, 1/4- -1'-O^ A2 - }}� NOTE: PALM SET IS'r'Ao DRAWING Al 4 A2 f ryM i / e Barnstable. • Mass. O � � II / -- Oro 11 8g race d'stonce he ! a i SMH ,@ Station 17+43 ll o a Record rim elev. = 39.37 �s�38.6 Record invert elev. = 31.51 / - Located rim elev. = 38.6 g AssessorsEMapA�4D, Parcel SB t yOte yeia record d/ dot 26 Approximate invert elev. = 30.74 c c lO ces f or /o is 26 through 32 ll ° OWNER OF RECORD: dye/d in -0 e Deed Book of Barbara r own4565, Page 19 tersection fences f Plan Book 9, Page 119 °r iine.) Lot 25 & 30' of Lot 24 Approximate location of ll o d e A p 38.7 O ll a Q � a S x 39,1 39.4 74,7 existing gas service. 38.3 ll ll � ZONING REQUIREMENTS � 39.5 re Deed o'ist°nc O 11 �nL1` w � Zone SF (Single Family x 39.3) a 39,2 ll Minimum Area g 20,000 SF. Existing Fence LO �� 3� 388 38.3 ll Minimum Frontage 20 Ft. Minimum Lot Width 100 Ft. 39.3 38.7 ll h Front Yard Setback 20 Ft. p x 39,7 Of LO t 2`�'•x 40.1 aai 11 Side and Rear Yard Setback f0 Ft. y 40.3 v Maximum Lot Coverage N/A 39.6 g O c IlApproximq#e location of Floor Area Ratio (FAR) N/A Area = 13,854 S.F.f g ll o x 39.8 gO_y� 11 existing water service, to bto Q x 39.6 Or 0.318 Ac.f O o 11 be relocated as �• II necessary. C� x 39.7 x 39.5 C (1), a ll •� ,� D. x 39.4 Approximate location of I ® 4os \ s ll existing sewer connection. 40.5 ' 1 ,moo' -w I Station 16+41f a y W Proposed w q) 39.6 0 o m ° v h W 39.3 6 38,4� Invert elev. = 30.4 f o Q dri;-eway 39.3 ll O p V x h ll 0 40,0 p 39.3 39.4 5 38.2 38.0 11 1 39.3 39.0 x39.3 J-;,k39.8 Approximate location of f� b 39,1 fig0 S ll exsn sewer, new 39.0 x 39.238.9 existing g "`I w wip 39.0 39.2 5 2 38,0 ll sewer connection to be 39.0 ,r O [i 39.0 s ahU 3e.2 II connected by wye and 139.4 k 3 38,9 w U 38.9 38.4 11 cleanouts to be odde �•AAOF'�SS " 38.139.2 4V U 31 x ll to both connection 50, 38,6 =s��`pJAMESP.�'yG 38.9 71 36 38.5 39.9A x 11 pipes. o MaGU1RE Ill cn I 39.3 11 E MECHANICAL Proposed 1 39.1 392 W BENCHMARK.- o No.2 y W / water service. Proposed sewer 39,2 388 38.5 ll Top of CB Fnd (Broke o 9 �o cleanout with Pro osed 3a.s 11 Elev. = 38.6 is p Date: 05-01-2006 H-20 access sewer 39.1 38.6 ll Re cover. ical CB Fnd 3s.o ll Scole: 1'= 20- _ rnoinder t ( }'p � service. Proposed of C o 24 underground (Broken, O 20 40 60 Project b�33/3-01.0 -__ utilities. held center) I �i ©Copyright Surveying by g 3313 010 Haskell Brown\331J 010 Sewer Connection 2006-05-OLdwg Sheet No.: Eldredge Sunreying 1 of I • 1 of 6 4 . / Barnstable r Mass. : o lb N Note. He/d %o °t 26 . Q or �ooa 9h FoJoo / d distances for do ts 2 0 6 throu (Held9h 32 . a intersection of n l fe ces to est o d 2b/11 sh y KEY MAP 5r6 '°rO,o ert y //n Assessors' Map 140, Parcel S8 ed dicta nce OWNER OF RECORD: Exis tin g Fence C) v Barbara Brown L o t 25 1& 3 o Q) v Deed Book 4565, Page 19 v �+ 3 Plan Book 9, Page 119 0 of L o i, 24 a Lot 25 & 30' of Lot 24 a Area = 13,654 S.F.f a ZONING REQUIREMENTS v Or 0.318,Ac..t i Zone SF (Single Family) ----Minimum Area 20,000 S.F. 8 9 Minimum Frontage 20 Ft. 3 y Minimum Lot Width 100 Ft. Front Yard Setback 20 Ft. Side and Rear Yard Setback 10 Ft. EXistin9 z W Maximum Lot Coverage N/A f"°u Floor Area Ratio (FAR) N/A ndation Is, o o Q) ► , I 150. 71, q ( l certify to Barbara Brown, Bruce Haskell and 1� Thomas Perry, Building Commissioner for theTown of (� o (V� knowledge arnst and inl my opinion, o f tbased on best fthe Remoi�der CB Fnd w V' plan of record dated March, 1922, prepared by Lot 24 + (Broken, Clement & Spear - Civil Engineers, for Willis a held center)_ Eldridge and Louise Johnson, recorded in the v (� c Barnstable County Registry of Deeds as Plan Book 9, Page 119 and the concrete monument t o0 (CB) found and noted "Held" the foundation shown on this plan is located on the ground SM Of 414s as shown hereon. SgcR C Date ; f� O Date: 06-02-2006 ELDREDG r PK Fn d Scale. 1" = 20' .� No.46471 (Held for Line to fix Project No.: S. iO9pf NPR' Ridgewood Avenue) 0 20 40 60 b-3313-01.0 �� f S10 OQ Sheet No.: Copyright Surveying bg N�SUR v 3313 010 Haskell Brown\3313 010 CPP 2006-06-02dwg Eldredge Surveying � of 1 ' STAR NOTE: / .. I)TREADS P.T., 2)USE(3)2x12 STRINGERS. 3)PLATFORM POST 6.6 W/SIMP50N AC TOP AND AB66 BASES. 4)STAIR POST 4x4 PT W/SIMPS d AC TOP, B 26-0° A44 BASES ...... — —.--__... __. _._... ...... _ 26'-0 5 DE51GN HEIGHT b 0 DOOR, 15R STAIR ° CONCRETE PAD;IBe f____.._.. ._... _. ... _...._._ ._..._ _ ._ ..._. ____ _ __......._. y ) ( A%q'3 13'-I 1/2' .3-10° _ ._.. 8 6 I/4" ... HAUNCH 15 BOTTOM 12 10 3/4°114T@II 7 - 1/1° B'-3 I/2" I�- --TO Bs SONOTUBE TREAD -_._.. /- .. O-)D FRn 6'-9 I/2° SUB FLOOR 7°R M y 4 10'BOND TUBES TO -'�,.'A V . __ - 4-O -I BELOW GRADE. /!• I k SLAB C�RADE� HOLD UP 6" FOR POST I I I I I i l l II j 3'-6 /2' b'-q° W�I 6' 1/2 ITW3046 /Ox(/ TWI8310 WALL GRADE-(0-0' LGT SLAB GRADE-(0-6° r,D �' • �' FACE FR 1 10-4 1/4°FIRM 1 3 10 1/2° 5'-I 1 4 3'-4' . I M Ni -� Lo si O ryf ' NI S NO l 2/4x6/5 - c a2 .I 4/Oxb/8 2/6X6/8 x_ Qm LLw COy _e__pee______.. .� n -I 9'-2" dw �o< 30x30x14"FOOTING W/ 0 i ( I US REBAR WALL GRADE BOTTOM --O SLAB GRADE-3/O%6/8 LGT TOP DROPPED FOUND)) ATION _(0_11°) mUJ U o z V�H r i i HM omAD nw� _ in I 1 I SLAB BADE-(0-9°) TW2046-r)PP5646-TW2046 TOP DROPPED FOUNDATION-(I-3 0 `ol m °I'_be I2:_O°' 9,-b° 21 APRON SLOPE DOWN 2 Z3 I 2'-9° 9'-0° 2-6 1 q'-O° a`' 2'-9° i APRON SLOPE DOWN t3°;GROUND B DRIVE t-(0-12') _�/��► 0 N Q ix FIRST FLOOR PLAN SECOND FLOOR PLAN FOUNDATION PLAN O y��` W SCALE: 1/4"=I'-0" - SCALE: 1/4 SCALE: I/4"m I'-O° "-1'-0" aZ CONTINUOUS RIDGE VENT U O 2 x 12 RIDGE —'--'---- - -- TYPICAL ROOF CONSTRUCTION:' - ARCH.GRADE ASPHALT ROOF SHINGLES,P 2 x 12 RIDGE' Ix6 HANGER P w O.C.- 15 LB.FELT PAPER 5/B'COX PLYWOOD WH'CLIPS - M A W 2.4 CONTINUOUS, TIE SHEATHING/2 x VS P)6'O.C. + - OC TO GABLES ...____ 12 NOTES: 2.4.30'BLOCKING 46 1)GRADE ELEVATIONS GIVEN FOR REFERENCE, SITE TO GOVERN _ FIELD VERIFY.MINIMUM GRADE TO TOP FOUNDATION B', ALLOW SIMPSON 2.5 CLIP, / - FOR SLOPED AP ROJ AT OVERHEAD DOORS, PROVIDE STEP 'SIDE EXTERIOR DOOR IF REQUIRED. EACH RAFTER 2)REAR STAIR VERIFY TOTAL RISE AND ADJUST RISERS AS Iz2, Iz8 FASCIA(RIPPED) (f I) 0 n 0 _ W/CONTINUOUS VENTING-'- SE 5 3)SECOND LEVEL(JOIST UM IBCI A I/2"P 16°O.C.TYPE PER 2 x b NAILER CONTINUOUS MANUFACTURE.4)LVL SHOWN AS(5)1 3/4"x 14"LVL 15 TO 6 BE/SF, DEAD LOAD OF 15a PER S A DECK LIVE LOAD OF 2 x 4 @ 16°O.C..._.__....... _ 12 LOCATED 0 3'-4°. 5)BIRCHALL CONSULTING HAS BASED ALL D� KNOWN LOCAL CODES AND BEST ENGINEERING PRACTICES BUT 22UMES NO RESPONSIBILITY FOR ERRORS OR OMISSIONS. ,__.Pq� ,""'TYPICAL 3/-0°CDX T<G SMOKE DETECTARS RE�fIL'VI�L�► Z V, LYWOOD 9UBCDLX�TF,/G 3_4 PLYWOOD SUB FLCAR ---- GLUED 1 NAILED _ GLUED 4 NAILED if 7 - � -9 I/4°LPI B 16°O.C. .__(3)I �x14 LVL BAR STABLE BUILDING DEPT., . DATE Z W GARAGE py l�f 2 z 60 MID HGT. = v' , 4 OF STUD WALL TYP. /-� 'v V/ OF ALL EXTERIOR WALLS ..._ ....'.., 1/2'COX PLYWOOD SHEATHING .1- 2 x 6 SHOE FIRE DEPARTMENT DATE _ O_ -}--2 x B TREATED SILL 2.e TREATED SILL BOTH SIGNATURES ARE REQUIRED FOR PERMITTING _J z i off, k- - - _.....4°CONCRETE SLAB R .—_.4°CONCRETE SLAB ON z 6"CRUSHED STONE AND 6"CRUSHED STONE AND - z ° 6 MIL. POLY VAPOR BARRIER 6 MIL. POLY VAPOR BARRIER IMPORTANT - UPGRADE REQUIRED d 0LL- " STATE BUILDING CODE REQUIRES THE UPGRADING OF = SMOKE DETECTORS FOR THE ENTIRE DWELLING WHEN I S EC:T I ON - t 2 SECTION ONE OR MORE SLEEPING AREAS ARE ADDED OR CREATED /� Q2 SCALE: 1/4°.1'-0° /A2 SCALE:I/4°.I'-0" -NOTE: A SEPARATE PERL41T IS-.REQUIRED FOR I 2 NOTE.PALN 5 IS TwH& ION OF SMOKE DETECTORS—THE ELEC AL PERMIT DOES NOT SATISFY THIS REQUIREME I P Multple Member Beams Multiple,Member Beams JOIST nalici -- -------- Side Loaded Connection Side Loaded Connection y REVISIONS: 1/2"dia. Bolt(b) 1 3/4"Versa-Lam AJS"'Blocking Panel BY: Nail Pattern Use 3"(10d)nails at 6"o.c. Toe nail rim board to plate w ith 2%"(8d)Wads at Bearing Wall Below G'o.c.or with 3Yz"(t6d)nails at 12"o.c. Rmboard and AJS ''fide-by-side. ------- Max Uniform Load Max.Uniform Load Nail rim board and rimjoist with �_-•_ � (Ibs.per lin.ft.) 16d common nails. 2'/"(8d)nails at 6"o.c. - - - -- Number of -_ 12"o.c. - - Numbers 24 o.c. 12"o.c. 6"o.c. See chart Bearing Wall Above - - - Nit each end 1 3/4"Versa-Lam -- ,�_ In.ft.) ,Nu' mberof ro per r _ _ _ with 1 3" (_ _ _ _ _ _ _ _ _ _ .' BoltSpaci --1R"dia. 2 500 1000 2000 Member 3 rows (10d)nail Load Bearing 2 rows Bolt(b) 2"min. 2 520 780 BWalls f_ 3 375 750 � 1500 Non-Bearing Wall Below ®' - 3(a) 390 585 4(a) 330 670 1330 H 2"min. Non-BearingWall Above (a)7"w ide members must be loaded f rom both s ides. (b)Design values apply to common bolts(grade 5 or higher) (a) Nail pattern for 3-piece member must occur on both sides. Use flat w ashers each side and drill holes 1/2"dia. Solid block all posts from ( Staggered c)Allvalues in the table above may be Increased 15%for snow loaded roofs ai 1/2"minimum end bearing length 25%for non-snow roofs where code allow s. Nail values may be increased by 15%for snow-load at all floor and roof details. above to bearing below. roofs and by 25%for non-snow roofs where 1-2'/p(8d)nail for Post Below Post Above building code allows. each' istflan a Versa-Lam LVL beam Attachment at End ;' Multiple Member Connection Bolt Multiple Member Connection Nail F13-D kind Panels at Interior Bearing Post Load Transfer Rim Board LVL Header O enin Exterior End Wall Su ort F 14- CF1 F 13-C --pp-- F50 F49 -- - N.T.S. fF13-E F08 - N.T.S. Si. % N.T.S N.T.S. N.T.S. N.T.S. N.T.S. Post Above & Below r� Z 0 W W 0 � (L J W W W O � > W Z Q W 2 W m 1-- 2 0 Z J USE LVL FOR RIM AT ALL ATTACHED DECKS. Q - l 11 I II II II 11 II II II II II a �1 r 11 II II II � 1 II 11 II - 1 11 II 11 11 II II 11 II 1 I ) II 11 I ) II II 11 11 1 Room over Garage Framing Schedule - Nominalized I I I I I I I Notes: Tag Qty Description Length --------- 1 _J Shop drawings, typical details I I I I 1 I 21 9-1/2" AJSTM 20 MSR 26' 0" and framing plans, outlining procedures and unit II II 3(3) II II - 11 identification marks, shall be ------- ---- --- --III submitted for approval by the I t project architect and/or engineer. 1 BLK 9-1/2" AJSTM 20 MSR 28' 0" Exact quantities and lengths are ' I ---—————————- —— —— —— ——————— the responsibility of the contractor. ram-- I I II Contractor is to verify all beams 1 and joists at their exact locations. IIif1 The floor system (1-joist, LVL) are designed for floor loads only. I I II I I 1 II I Roof loads from rafters, bracing, -------I-I------ ------------' 5 and beams must bear on exterior walls and interior walls with bearing 1 straight through to a footing. Any roof loads carried by the floor system must be so indicated on the framing �S/ IZVOCIP plan submitted to us for take-off. 4` Product to be stored, handled and installed in accordance with 1 _J manufacturer's recommendations. 1 1 It I 1 II 1 it I I II I II n1 ul 1 I 1 u I ul ' ul 1 I I n I 1 1 ' I I nl 5 a� CoE :3 C (� C U L N START FRAMING HERE j -a fn°o cn Level 1 Al 6 3 9-1/2" AJS 20 MSR m CU ° a) 16" OCS =_ o 0 aCL L C: L1 W _ BC FRAMER® 6 SCALE: 3/8" = 1'-0" DATE: 5/10/2006 BY: be FILE: DeMartin Haskell.bcf DWG: SHEET: 1 / 1