Loading...
HomeMy WebLinkAboutCOA 6 Harvey AvenueNJ, ElectricalContractor business permit number34EB01547400 NJ, HIC reg. #13VH01244300 For other jurisdictions, please visit: http://www.trinity-solar.com/about-us/locations-and-licenses HOMEOWNERS AUTHORIZATION FORM I, , (print name) am the owner of the property located at address: . (print address) I hereby authorize Trinity Solar Inc.(“TrinitySolar”)and its employees, agents, and subcontractors, including without limitation, , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System, Battery System, roofing or other Trinity Solar offerings located on my property, applying and obtaining permission and approval for interconnection with the electric utility company, and registration with any state and/or local incentive program(s). This authorization includesthe transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Without limitation to the generality of theforegoing Ispecifically authorize Trinity Solar et al. to populate technical details, fill-in, edit, compile, attach drawings, plans, data sheets and other documentation to, date, submit, re-submit, revise, amend and modify application, submission and certificationdocuments(“ApprovalsPaperwork”),includingthoseforwhichsignaturepages areincluded herewith for my signature, in furtherance of the relatedtransaction, and I am providing any signatures to Approvals Paperwork for purposes of the foregoing. Trinity Solar will provide copies of Approvals Paperwork when submitted. My authorizations memorialized herein shall remain in full force and effect until revoked. I acknowledge that theseauthorizations are not required to proceed withthe transaction andare not a condition of the related agreement included herewith but are being given for my own convenience and benefit in order to expedite the approvals processes. ElectricUtility Company: ElectricUtilityAccount No.: Name on Electric Utility Account: Customer Signature PrintName Date CorporateHeadquarters1-877-SUN-SAVES 2211AllenwoodRoadPh:732-780-3779 Wall,NewJersey07719Fax:732-780-6671 www.trinity-solar.com  FORINFORMATIONABOUTCONTRACTORSANDTHECONTRACTORS’REGISTRATION ACT, CONTACT THE NEW JERSEY DEPARTMENT OF LAW AND PUBLIC SAFETY, DIVISION OF CONSUMERS AFFAIRS AT 1-888-656-6225. Trinity Solar & Air Inc. Douglas Mercer 6 Harvey Ave Barnstable 1454 662 0023 EVERSOURCE MA Douglas Mercer Mercer Douglas Douglas 1/6/2023 500.00 This map is for illustration purposes only. It is not adequate for legal boundary determination or regulatory interpretation. This map does not represent an on-the-ground survey. It may be generalized, may not reflect current conditions, and may contain cartographic errors or omissions. Parcel lines shown on this map are only graphic representations of Assessor’s tax parcels. They are not true property boundaries and do not represent accurate relationships to physical objects on the map such as building locations. 83042 Feet feetApprox. Scale: 1 inch =42 Legend Town of Barnstable GIS Unit 367 Main Street, Hyannis, MA 02601 508-862-4624 gis@town.barnstable.ma.us Map printed on:3/2/2023 Road Names INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 6 HARVEY AVE BARNSTABLE, MA 02630 41.706914,-70.291072 HARVEY AVE P1 ISSUED TO TOWNSHIP FOR PERMIT 2/3/2023 NO.DESCRIPTION DATE MERCER, DOUGLAS- TRINITY ACCT #: 2023-01-813236 6 HARVEY AVE BARNSTABLE, MA 02630 41.706914,-70.291072 PROPOSED PV SOLAR SYSTEM DRAWING DATE:2/3/2023 DRAWN BY:TP REVISED BY: DC SYSTEM SIZE:9.2kW AC SYSTEM SIZE:7.6kW MODULE COUNT:23 MODULES USED:HANWHA 400 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 400 UTILITY COMPANY:EVERSOURCE UTILITY ACCT #:14546620023 UTILITY METER #:2301563 DEAL TYPE:SUNNOVA P1 R 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ROOF 1 MODULES: 10 PITCH: 9 ORIENTATION: 294 ROOF 2 MODULES: 5 PITCH: 9 ORIENTATION: 114 ROOF 3 MODULES: 8 PITCH: 43 ORIENTATION: 204 ROOF 4 MODULES: 0 PITCH: 23° ORIENTATION: 114° ROOF 5 MODULES: 0 PITCH: 43° ORIENTATION: 24° ROOF 6 MODULES: 0 PITCH: 30° ORIENTATION: 294°NS27090 135 22545315DC AC D ep M TS 41.706914,-70.291072 23 HANWHA 400 (Q.PEAK DUO BLK ML-G10+ 400) 1 SE7600H-US000BEi4 INSIDE OUTSIDE. OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE. P1 ISSUED TO TOWNSHIP FOR PERMIT 2/3/2023 NO.DESCRIPTION DATE MERCER, DOUGLAS- TRINITY ACCT #: 2023-01-813236 6 HARVEY AVE BARNSTABLE, MA 02630 41.706914,-70.291072 PROPOSED PV SOLAR SYSTEM DRAWING DATE:2/3/2023 DRAWN BY:TP REVISED BY: DC SYSTEM SIZE:9.2kW AC SYSTEM SIZE:7.6kW MODULE COUNT:23 MODULES USED:HANWHA 400 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 400 UTILITY COMPANY:EVERSOURCE UTILITY ACCT #:14546620023 UTILITY METER #:2301563 DEAL TYPE:SUNNOVA P1 NOTES: 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. M UD SP P DC AC ep D DC R 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SD TS CALCULATIONS FOR CURRENT CARRYING CONDUCTORS REQUIRED CONDUCTOR AMPACITY PER STRING [NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A AWG #10, DERATED AMPACITY AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96 RACEWAY DERATING = 4 CCC: 0.80 (40*.96)0.80 = 30.72A 30.72A >_ 18.75A, THEREFORE WIRE SIZE IS VALID TOTAL AC REQUIRED CONDUCTOR AMPACITY 32.00A*1.25 = 40.00A AWG #8, DERATED AMPACITY AMBIENT TEMP: 30°C, TEMP DERATING: 1.0 RACEWAY DERATING <_ 3 CCC: N/A 55A*1.0 = 55A 55A >_ 40.00A, THEREFORE AC WIRE SIZE IS VALID CALCULATION FOR PV OVERCURRENT PROTECTION TOTAL INVERTER CURRENT: 32.00A 32.00A*1.25 = 40.00A --> 40A OVERCURRENT PROTECTION IS VALID ARRAY CIRCUIT WIRING NOTES 1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2020 2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP = -16°C 3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP = 33°C 4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) 5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A) THROUGH (D) 6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41 (A)(4) 7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: POSITIVE CONDUCTORS = RED NEGATIVE CONDUCTORS = BLACK NEC 210.5(C)(2) 8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤ 9 CURRENT CARRYING CONDUCTORS. 9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS OTHERWISE NOTED 10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12” IF USED OUTDOORS 11.)OVERCURRENT PROTECTION FOR CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE LOCATED WITHIN 10' OF THE POINT OF CONNECTION NEC 690.9(A)(3)(2) 12.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A UTILITY AND THE OTHER AN INVERTER, PV BACKFEED BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY NEC 705.12(B)(3)(2) 13.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED POSITIONS OR LOADS 14.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3R RATING NOTE: INTERNAL REVENUE GRADE MONITORING CONTAINED WITHIN SOLAR EDGE INVERTER SOLAR EDGE PN. RWND-3D-240-MB E INVERTER #1 - SE7600H-US000BEi4 DC AC Imp 20 Pout 7600 Vmp 400 Imax 32 Voc 480 OCPDmin 40 Isc 30 Vnom 240 PV MODULE SPECIFICATIONS HANWHA 400 (Q.PEAK DUO BLK ML-G10+ 400) Imp 10.77 Vmp 37.13 Voc 45.3 Isc 11.14 A #6 THWN-2 GEC TO EXISTING GROUND ROD B 3/4'' CONDUIT W/ 2-#8 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND C 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND D 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND E 3/4'' CONDUIT W/ 2-#8 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2, 1-#8 THWN-2 GROUND NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS INVERTER #1 PV+L1 L2 N PV-D SOLAR MODULES MOUNTED TO ROOF ON 3 ARRAYS 23 - 400W MODULES W/ 1 SOLAR EDGE S440 PER MODULE 15 ADC MAX PER STRING 1 STRING OF 11 MODULES IN SERIES - 400 Vmax 1 STRING OF 12 MODULES IN SERIES - 400 Vmax *2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 f 8"x8" JUNCTION BOX LOCKABLE 60A DISCONNECT FUSED W/ 40A FUSES SQUARE D PN: D222NRB BONDED NEUTRAL 240V 1Ø G NEW PVC TAP BOX INSULATED LINE TAPS TO BE INSTALLED ON MAIN FEEDERS NEC 705.12(A) EXISTING MAIN BREAKER LOAD CENTERNEUTRAL2p200AMAIN240V1Ø EXISTING 120/240V UTILITY METER EXISTING GENERATOR M NEUTRAL2P200A G EXISTING MAIN BREAKER LOAD CENTER EXISTING GENERATOR TRANSFER SWITCH 200A MAIN BREAKER 200A BUSBAR P1 ISSUED TO TOWNSHIP FOR PERMIT 2/3/2023 NO.DESCRIPTION DATE MERCER, DOUGLAS- TRINITY ACCT #: 2023-01-813236 6 HARVEY AVE BARNSTABLE, MA 02630 41.706914,-70.291072 PROPOSED PV SOLAR SYSTEM DRAWING DATE:2/3/2023 DRAWN BY:TP REVISED BY: DC SYSTEM SIZE:9.2kW AC SYSTEM SIZE:7.6kW MODULE COUNT:23 MODULES USED:HANWHA 400 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 400 UTILITY COMPANY:EVERSOURCE UTILITY ACCT #:14546620023 UTILITY METER #:2301563 DEAL TYPE:SUNNOVA P1 R 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com JOB NAME:MERCER, DOUGLAS- ADDRESS:6 Harvey Ave Barnstable, MA 02630 41.706914,-70.291072 61.8 ESTIMATED PERSONNEL HOURS 2.58 DAYS 1.93 DAYS 1.29 DAYS •23 HANWHA 400's (9.2KW)(CREW OF 3)(CREW OF 4)(CREW OF 6) •3 SEPARATE ARRAYS •17' PEAK TO GROUND •12 PORTRAIT & 11 LANDSCAPED •1 INVERTERS INSTALLED OUTSIDE •NO TRENCH ESTIMATED SENT TO JOB USED □HANWHA 400 (Q.PEAK DUO BLK ML-G10+ 400)23 ______ □S440 SE OPTIMIZERS 23 ______ □SE7600H-US000BEi4 1 ______ □60A OUTDOOR FUSED DISCONNECT W/ (2) 40A FUSES 1 ______ □60A OUTDOOR NON-FUSED DISCONNECT 1 ______ □SOLADECK BOX(ES) & HAYCO CONNECTOR(S)3 ______ □PV LEAD WIRE 100'______ □INSULATED BUG BITES (LINE TAPS)2 ______ □CASE(S) OF BLACK SPRAY PAINT 1 ______ □CASE(S) OF TAR 1 ______ □ECOFASTEN 2012025 CF STD RAIL MLL AL 171.5 19 ______ □ECOFASTEN 2012013 CF RAIL SPLICE 7 ______ □ECOFASTEN 2099017 CF END CLAMP 32MM BLK 48 ______ □ECOFASTEN 2099022 CF MID CLAMP SHORT BLK 22 ______ □ECOFASTEN 4011011 MODULE JUMPER 9 ______ □GROUNDING LUG (NOT PROVIDED BY ECOFASTEN)3 ______ □ECOFASTEN 2012022 CF UNIV L-FOOT MLL 3 72 ______ □ECOFASTEN 3012020 GF-1 FLASHING GLV BLK 8 x 10 72 ______ □ECOFASTEN 2012019 CF MLPE MOUNT 23 ______ □ECOFASTEN 2012020 CF WIRE MGMT CLIP 23 ______ □ECOFASTEN 2012024 CF END CAP 48 ______ MATERIAL LIST R(FOR INTERNAL USE ONLY) 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 6 HARVEY AVE MERCER, DOUGLAS- 6 HARVEY AVE BARNSTABLE, MA 02630 41.706914,-70.291072 R APPENDIX CONTENTS LABELS, STICKERS, AND PLACARDS EQUIPMENT DATA SHEETS 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com 201 COMMERCE ROAD BARNSTABLE, MA 02630 318013 HANSEN, ROBERT W & JOANNE C TRS MARASPIN CREEK REALTY TRUST Property ID: 191 COMMERCE ROAD BARNSTABLE, MA 02630 318014 CHILDS, BRUCE ANTHONY TR BRUCE ANTHONY CHILDS REV TR Property ID: CENTERVILLE, MA 02632 318019 KELLY, MARINA PO BOX 249 Property ID: 1400 MARINA DRIVE HOLLYWOOD, FL 33019 318020 MERCER, DOUGLAS H & DONNA TRS DOUGLAS H MERCER TRUST Property ID: BARNSTABLE, MA 02630 318043 WOLFE, CHESTER F 13 LOCUST LN Property ID: 188 COMMERCE ROAD BARNSTABLE, MA 02630 319140001 GEORGE, LLOYD H TR GEORGE FAMILY TRUST DATED 7/11/14 Property ID: 188 COMMERCE RD BARNSTABLE, MA 02630 319140002 GEORGE, LLOYD H TR GEORGE FAMILY TRUST DATED 7/11/14 Property ID: