Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
COA 247 High Street
for Committee use only By a vote of Conditions of Approval This Certificate is hereby APPROVED DENIED Aye Nay Abstain Date __________________________ New Build Addition Alteration Residential Type of Building House Garage Barn Shed Other Project Roof Windo ws/Doors Siding/Painting Solar Other Landscape Feature Fence Wall Flag Pole Pool Other New Sign Replace Sign Repaint Sign Town of Barnstable Old King's Highway Historic District Committee 367 Main Street, Hyannis, Massachusetts 02601 Telephone: (508) 862-4787 Email: erica.brown@town.barnstable.ma.us APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made, with one (1) complete, colored set, for the issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts and Resolves of Massachusetts, 1973, for proposed work as described below and on plans, drawings, or photographs accompanying this application for: Date Date Built: Map & Parcel Property Ow ner Phone Street address Email Village Mailing address Signature Agent/Contractor Phone Agent Address Email Agent Signature If approved, the Certificate of Appropriateness expires one year from the stamped approval date or upon the expiration of a Building Permit, w hichever date shall be later. A one year ex tension may be requested, in w riting, to the Old King’s Highw ay Administrative Assistant at 367 M ain Street, Hyannis, M A 02601. This request must be received prior to the date of expiration. There is a 10 day appeal period plus a four day waiting period for all applications after w hich time your approval paperw ork w ill be availabl e for pickup and building per mit sign-off. All applications are subject to meeting any applicable building code requirements. Check all categories that apply Building Construction Commercial Sign Other _ Description of Proposed Work 02/20/2023 1935 111016 #247 Kenneth Aittaniemi (508) 654-0543 247 High St. WB 247 High St.Barnstable, MA 02668 See Attached Contract Sunrun Installation Services Inc./ Stephen Kelly 978 793-7881 eastmapermits@sunrun.com695 Myles Standish Blvd. Taunton, MA 02780 Installation of a rooftop mounted photovoltaic solar energy system consisting of 22 solar panels. Two solar arrays on the East and West facing roof planes, black panels with a matte finish. Both arrays will be visible from the public way (High St.) wildclams@comcast.net CHECKLIST – CERTIFICATE OF APPROPRIATENESS Please com plete the Checklist that is applicable to your project. Submit electronic complete colored set, unless otherwise noted FEES Filing Fee according to fee schedule, please make checks payable to the Town of Barnstable Legal Ad fee, will be billed, made payable to the Town of Barnstable First Class Postage Sta mps for abutter notification. Please contact Barnstable Old King’s Highway Office for correct count ALTERATIONS (new paint color, change of siding material, roofing, windows, doors, shutters, etc) Application for Certificate of Appropriateness Spec Sheet, brochures and color samples Plans of building elevatio ns/photographs, ONLY if there is a change to the location and size of the windo w (s) or Door (s). MINOR ADDITIONS (decks, enclosing a porch, sheds (over 120 sqft) Application for Certificate of Appropriateness, Spec Sheet, brochures and color samples Site Plan, ONLY if there are changes to the footprint (see site plan criteria below) A site plan drawn on a mortgage survey plan or GIS map may be used for minor additions, UNLESS the porch, deck, pool, or Shed etc. is close to lot lines, zoning setback lines, or other buildings, in which case a certified site plan must be submit ted Photographs of all building elevation affected b y any proposed alterations Plans 2 full scale plans, plus 4 copies of the plan at reduced scale to fit 8.5x11 or 11x17 paper Co mpany brochure of manufacturers shed or to -scale sketch or affected structure or building elevations ASSESSORY STRUCTURES, NEW/ALTERED (fences, new stonewalls, changes to retaining walls, pools etc) Application for Certificate of Appropriateness Spec Sheet, brochures &/or diagram Site Plan (see site plan criteria below) Photographs of any existing structure that will be affected by the change SIGNS (complete sign supplement) Rendering of the proposed sign, sho wing graphics, dimensions, design and height of post, color, and materials Site Plan on GIS map or mortgage survey, or photograp hs, or to-scale sketch of building elevation sho wing location of Proposed sign; and any tree to be removed near a freestanding sign (see below for site plan criteria) SOLAR PANELS (complete solar panel supplement) Drawing of locations of panels on house showing roof and panel dimensions Site Plan sho wing location of building on property (see site plan criteria below) SITE PLAN CRITERIA Name of applicant, street location, map and parcel Name of architect, engineer, or surveyor; original stamp & signature; date of plan & revision dates North arro w, written and drawn to scale Changes to existing grades shown with one -foot contours Proposed & existing footprint of building and/or structures, and distance to lot lines Proposed driveway location Proposed limits of clearing for building (s), assessor structure (s), driveway and septic system Retaining walls or accessory structures (e.g. pool, tennis court, cabana, barn, garage, etc) SOLAR PANEL SUPPLEMENT STRUCTURE ONE STRUCTURE TYPE Ho me Garage Barn ELEVATION PLACEM ENT North ROOF M EASUREM ENTS South East West Length SOLAR PANEL M EASUREM ENTS Height Pitch Length SOLAR PANEL TYPE & FINISH Depth Width Color Finish (matte or glossy) STRUCTURE TWO STRUCTURE TYPE Ho me Garage Barn ELEVATION PLACEM ENT North ROOF M EASUREM ENTS South East West Length SOLAR PANEL M EASUREM ENTS Height Pitch Length SOLAR PANEL TYPE & FINISH Depth Width T ype Roof Mounted Ground Mounted Canopy/Carport System Color Finish (matte or glossy) Solar Co mpany Phone Solar representative Print Name Signature Date 1 story 69.06"1.18"43.15" MatteBlack 44'3"33 deg 44'3"1 story 34 deg 69.06"1.18"43.15" Black Matte Sunrun Installation Services Inc. Stephen Kelly 978 793-7881 02/20/2023 1,000.00 This map is for illustration purposes only. It is not adequate for legal boundary determination or regulatory interpretation. This map does not represent an on-the-ground survey. It may be generalized, may not reflect current conditions, and may contain cartographic errors or omissions. Parcel lines shown on this map are only graphic representations of Assessor’s tax parcels. They are not true property boundaries and do not represent accurate relationships to physical objects on the map such as building locations. 167083 Feet feetApprox. Scale: 1 inch =83 Legend Town of Barnstable GIS Unit 367 Main Street, Hyannis, MA 02601 508-862-4624 gis@town.barnstable.ma.us Map printed on:3/2/2023 Road Names COVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS PAGE REV: A 2/18/2023 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 KENNETH AITTANIEMI 247 HIGH ST, BARNSTABLE, MA, 02668 PROJECT NUMBER: 223R-247AITT SHEET DESIGNER: MILJEN BUMOTAD CUSTOMER RESIDENCE: TEL. (508) 654-0543 APN: BARN-000111-000000-000016 #180120 (415) 580-6920 ex3 PV-1.0 VICINITY MAP • SYSTEM SIZE: 8580W DC, 6000W AC • MODULES: (22) TRINA SOLAR: TSM-390DE09C.07 • INVERTERS: (1) SOLAREDGE TECHNOLOGIES: SE6000H-USSN • RACKING: TOPSPEED, SEE DETAIL SNR-DC-30004 • ALL WORK SHALL COMPLY WITH MA 9TH ED. CMR 780 (2015 IRC/IBC/IEBC), MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 13.35 AMPS MODULE SHORT CIRCUIT CURRENT. • 20.85 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)]. • PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM EXT EXTERIOR INT INTERIOR MSP MAIN SERVICE PANEL (N)NEW NTS NOT TO SCALE OC ON CENTER PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS TYP TYPICAL V VOLTS W WATTS LAN LANDSCAPE POR PORTRAIT SOLAR MODULES TOPSPEED MOUNT LEGEND SCALE: NTS MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT SERVICE ENTRANCE IQ COMBINER BOX HARDSCAPE PROPERTY LINE INTERIOR EQUIPMENT SHOWN AS DASHED PL SE MP SP LC SM PM INV AC DC Template_version_4.0.87 SHEET INDEX PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE • NEW 100A MAIN BREAKER DISCONNECT WITH 100A MAINE ENCLOSURE . • SERVICE ENTRANCE CONDUCTORS TO BE REPLACED. PRODUCTION METER PLPLPLPLPL PLPLPLPLP L PAGE REV: A 2/18/2023 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 KENNETH AITTANIEMI 247 HIGH ST, BARNSTABLE, MA, 02668 PROJECT NUMBER: 223R-247AITT SHEET DESIGNER: MILJEN BUMOTAD CUSTOMER RESIDENCE: TEL. (508) 654-0543 APN: BARN-000111-000000-000016 #180120 (415) 580-6920 ex3 SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP SITE PLAN - SCALE = 3/32" = 1'-0"SITE PLAN DETAIL- SCALE = 3/128" = 1'-0" Template_version_4.0.87 (E) RESIDENCE (N) ARRAY AR-01 (N) ARRAY AR-02 SE MP ACPMINV ARRAY PITCH TRUE AZIM PV AREA (SQFT) AR-01 33°287°206.9 AR-02 34°107°248.3 (E) DETACHED STRUCTURE HIGH ST PAGE REV: A 2/18/2023 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 KENNETH AITTANIEMI 247 HIGH ST, BARNSTABLE, MA, 02668 PROJECT NUMBER: 223R-247AITT SHEET DESIGNER: MILJEN BUMOTAD CUSTOMER RESIDENCE: TEL. (508) 654-0543 APN: BARN-000111-000000-000016 #180120 (415) 580-6920 ex3 D1 - AR-01 - SCALE: 1/8" = 1'-0" AZIM: 287° PITCH: 33° D2 - AR-02 - SCALE: 1/8" = 1'-0" AZIM: 107° PITCH: 34° PV-3.0 LAYOUT #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 30 PSF WIND SPEED: 140 MPH 3-SEC GUST. S.S. LAG SCREW (4) #14 X 2.25" SS SEALING WASHER WOOD SCREWS FULLY PENETRATING THROUGH WOOD DECK Template_version_4.0.87 INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. - MOUNT NUMBER FOR LEADING DOWNSLOPE EDGE SHALL MATCH REQUIREMENTS LISTED ABOVE INSTALL PER TOPSPEED™ INSTALLATION MANUAL. - CONTRACTOR MAY SUBSTITUTE SNAPNRACK DECKTRACK MOUNTS (SNR DETAIL SNR-DC-00453) WITH A MAX OVERHANG OF 6” 29' 7'-3" 12'-6"2'-9" 3'-2" 5'-1" 11'-7" 7'-3" 10'-11" 29' 11'-1"21'-7" 4'-2" 5'-4" 2'-11" 1'-9" ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max Span OC Spacing Detail Minimum Number of Mounts per Up-Slope Edge Max Landscape Overhang Max Portrait Overhang AR-01 COMP SHINGLE - TOPSPEED 1-Story 2X6 RAFTERS 11' - 11"24"TOPSPEED, SEE DETAIL SNR-DC-30004 3 1' - 5" 0' - 10" AR-02 COMP SHINGLE - TOPSPEED 1-Story 2X6 RAFTERS 11' - 9"24"TOPSPEED, SEE DETAIL SNR-DC-30004 3 1' - 5" 0' - 10" SEE SITE PLAN FOR NORTH ARROW PRREOEFE NIS GSNIOE N LA OF M H ATLSASEA CWHNUOSMETMTOSCVINCENT MWUMVANEZA CIVIL NO. 54772 STRUCTURAL ONLY Signed: 02/18/2023 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC 12 JUNCTION BOX OR EQUIVALENT SOLAREDGE TECHNOLOGIES: SE6000H-USSN 6000 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI, RAPID SHUTDOWN COMPLIANT PV MODULES TRINA SOLAR: TSM-390DE09C.07 (22) MODULES OPTIMIZERS WIRED IN: (1) SERIES OF (11) OPTIMIZERS (1) SERIES OF (11) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS S440 3 M 240V METER SOCKET 100A CONTINUOUS (N) MA SMART UTILITY REVENUE METER UTILITY SIDE OF CIRCUIT CONNECTS TO TOP LUGS - (LINE AT TOP LOAD AT BOTTOM) 3 (N) 35A PV BREAKER AT OPPOSITE END OF BUSBAR NEW 100A MAIN BREAKER DISCONNECT WITH 100A MAIN ENCLOSURE EXISTING 150A MAIN PANELFACILITY LOADS FACILITY GROUND M METER #: EVERSOURCE 2282723 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID EXISTING 100A MAIN BREAKER 3 CONDUIT SCHEDULE #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 PAGE REV: A 2/18/2023 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 KENNETH AITTANIEMI 247 HIGH ST, BARNSTABLE, MA, 02668 PROJECT NUMBER: 223R-247AITT SHEET DESIGNER: MILJEN BUMOTAD CUSTOMER RESIDENCE: TEL. (508) 654-0543 APN: BARN-000111-000000-000016 #180120 (415) 580-6920 ex3 PV-4.0 ELECTRICAL #ESTAMP SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: MAX ALLOWABLE DC VOLTAGE: SYSTEM OPERATING CURRENT: SYSTEM SHORT CIRCUIT CURRENT: 8580 W 11 V 380 V 480 V 22.58 A 30 A S440 OPTIMIZER CHARACTERISTICS: MIN INPUT VOLTAGE: 8 VDC MAX INPUT VOLTAGE: 60 VDC MAX INPUT ISC: 14.5 ADC MAX OUTPUT CURRENT: 15 ADC MODULE CHARACTERISTICS TRINA SOLAR: TSM-390DE09C.07: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 390 W 40.8 V 33.8 V 13.35 A Template_version_4.0.87 PAGE REV: A 2/18/2023 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 KENNETH AITTANIEMI 247 HIGH ST, BARNSTABLE, MA, 02668 PROJECT NUMBER: 223R-247AITT SHEET DESIGNER: MILJEN BUMOTAD CUSTOMER RESIDENCE: TEL. (508) 654-0543 APN: BARN-000111-000000-000016 #180120 (415) 580-6920 ex3 SIGNAGE PV-5.0 #ESTAMP NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION: 247 HIGH ST, BARNSTABLE, MA, 02668 SOLAR PANELS ON ROOF INVERTER (EXT) MULTIPLE SOURCES OF POWERWARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2023: 705.12(B)(2) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. 4" 3" LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2023: 690.12(D) ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2023: 690.13(B), 705.20(7), 706.15(C) PER CODE(S): NEC 2023 : 705.10(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2023: 690.12(D)(2), IFC 2018: 1204.5.3 THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING! LABEL LOCATION: PV LOAD CENTER (IF APPLICABLE) AND ANY PANEL THAT UTILIZES "THE SUM OF BREAKERS RULE". PER CODE(S): NEC 2023: 705.12 (B)(3) INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC480 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2023: 690.7(D) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2023: 690.31(D)(2) WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2023: 705.30(C) Template_version_4.0.87 PRODUCTION METER AC DISCONNECT SERVICE ENTRANCE MAIN PANEL(INT) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 25.00 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2023: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331PHONE 0FAX 0KENNETH AITTANIEMI247 HIGH ST, BARNSTABLE, MA,02668PROJECT NUMBER: 223R-247AITTCUSTOMER RESIDENCE:TEL. (508) 654-0543APN: BARN-000111-000000-000016#180120#SSTAMPSP#ESTAMPSPTemplate_version_4.0.87Proposed solar design for this residence includes 22 black solar panels with matte finish on two solar arrays.This view is from High St Approching from the East. This view is from High St Approching from the West. ARB Pg 1 Mono Multi Solutions 0~+5W POSITIVE POWER TOLERANCEMAXIMUM POWER OUTPUT 405W MAXIMUM EFFICIENCY 21.1% Trina standard Guaranteed Power90% 100% Years 5 10 15 20 25 98.0% 84.8% Trina Solar’s Backsheet Performance Warranty IEC61215/IEC61730/IEC61701/IEC62716/UL61730 ISO 9001: Quality Management System ISO 14001: Environmental Management System ISO14064: Greenhouse Gases Emissions Verication ISO45001: Occupational Health and Safety Management System Comprehensive Products and System Certicates PRODUCT: TSM-DE09C.07 PRODUCT RANGE: 380-405WBACKSHEET MONOCRYSTALLINE MODULE ×××××××××× EU-28 WEEECOMPLIANTRECYCLABLEPACKAGING High value • More productivity from same roof size. • Outstanding visual appearance. • Leading 210mm cell technology. Small in size, big on power • Small format module allow greater energy generation in limited space. • Up to 405W, 21.1% module eciency with high density interconnect technology. • Multi-busbar technology for better light trapping eect, lower series resistance and improved current. • Reduce installation cost with higher power bin and eciency. • Boost performance in warm weather with lower temperature coecient (-0.34%) and operating temperature. Universal solution for residential and C&I rooftops • Designed for compatibility with existing mainstream optimizers, inverters and mounting systems. • Perfect size and low weight makes handling and transportation easier and more cost-eective. • Diverse installation solutions for exibility in system deployment High Reliability • 25 year product warranty. • 25 year performance warranty with lowest degradation. • Minimized micro-cracks with innovative non-destructive cutting technology. • Ensured PID resistance through cell process and module material control. • Mechanical performance up to +6000 Pa and-4000 Pa negative load ELECTRICAL DATA (STC) ELECTRICAL DATA (NOCT) *Measuring tolerance: ±3%.STC: Irrdiance 1000W/m2, Cell Temperature 25ºC, Air Mass AM1.5. Maximum Power Voltage-VMPP (V) Maximum Power Current-IMPP (A) Open Circuit Voltage-VOC (V) Short Circuit Current-ISC (A) Module Eciency m (%) Maximum Power-PMAX (Wp) Power Tolerance-PMAX (W) Peak Power Watts-PMAX (Wp)* NOCT: Irradiance at 800W/m, Ambient Temperature 20°C, Wind Speed 1m/s. Maximum Power Voltage-VMPP (V) Maximum Power Current-IMPP (A) Open Circuit Voltage-VOC (V) Short Circuit Current-ISC (A) Electrical characteristics with dierent power bin (reference to 10% Irradiance ratio) 10%Irradiance ratio (rear/front) Open Circuit Voltage-VOC (V) Short Circuit Current-ISC (A) Maximum Power Voltage-VMPP (V) Maximum Power Current-IMPP (A) Total Equivalent power -PMAX (Wp) Power Bifaciality:70±5%. DIMENSIONS OF PV MODULE(mm) www.trinasolar.com CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. © 2022 Trina Solar Co.,Ltd. All rights reserved. Specications included in this datasheet are subject to change without notice. Version number: TSM_NA_2022_A Operational Temperature Maximum System Voltage -40~+85ºC 1500V DC (IEC) 1500V DC (UL) Modules per box: 36 pieces Modules per 40’ container: 828 pieces Monocrystalline Solar Cells Max Series Fuse Rating 25A MECHANICAL DATA TEMPERATURE RATINGS MAXIMUMRATINGS PACKAGING CONFIGUREATION WARRANTY (Please refer to product warranty for details) *Please refer to regional datasheet for specied connector. Portrait: 350/280 mm(13.78/11.02 inches) Landscape: N 1100 mm /P 1100 mm (43.31/43.31 inches) 1754×1096×30 mm (69.06×43.15×1.18 inches) 21.0 kg (46.3 lb) 3.2 mm (0.13 inches), High Transmission, AR Coated Heat Strengthened Glass EVA/POE 30mm(1.18 inches) Anodized Aluminium Alloy IP 68 rated Photovoltaic Technology Cable 4.0mm (0.006 inches), MC4 EVO2 / TS4* 120 cells Transparent backsheet Module Dimensions Weight Glass Encapsulant material Backsheet Frame J-Box Cables Connector No. of cells 43°C (±2°C) - 0.34%/°C - 0.25%/°C 0.04%/°C Temperature Coecient of P MAX Temperature Coecient of V OC Temperature Coecient of I SC NOCT(Nominal Operating Cell Temperature) 25 year Product Workmanship Warranty 25 year Power Warranty 0.55% Annual Power Attenuation 2% rst year degradation BACKSHEET MONOCRYSTALLINE MODULE Front View Back View A-A B-B Laminate Silicon Sealant Frame301754 33 11.5 11.5 3015.4 I-V CURVES OF PV MODULE(400 W)Current (A) PowerčWĎP-V CURVES OF PV MODULE(400W) Voltage(V) Voltage(V) 200W/m 400W/m 1000W/m 800W/m 600W/m 200W/m 400W/m 1000W/m 800W/m 600W/m 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 100 150 200 250 350 300 400 450 12.0 14.0 11.0 50 0 10 20 30 40 50 0 10 20 30 40 50 0 ~ +5 12.14 390 33.8 11.54 40.8 20.3 294 31.8 9.24 38.4 9.78 12.21 395 34.0 11.62 41.0 20.5 298 31.9 9.32 38.6 9.84 12.28 400 34.2 11.70 41.2 20.8 302 32.1 9.38 38.8 9.90 12.34 405 34.4 11.77 41.4 21.1 305 32.4 9.42 38.9 9.94 12.00 380 33.4 11.38 40.4 19.8 286 31.4 9.12 38.0 9.67 12.07 385 417 423 428 433407412 33.6 11.46 40.6 13.08 33.8 12.34 40.8 13.20 34.0 12.44 41.0 13.25 34.2 12.51 41.2 13.36 34.4 12.59 41.4 12.92 33.4 12.19 40.4 13.00 33.6 12.26 40.6 20.0 290 31.6 9.18 38.2 9.73 1754Laminate Silicon Sealant Frame 1096 104830 8-ȡ4.3Grounding Hole 8-Drain Hole 4-ȡ9×14Installing Hole A A BB1096 1100 Sunrun BrightSave™ Agreement Kenneth Aittaniemi 247 High St, Barnstable, MA, 02668 Take Control of Your Electric Bill $0 Deposit due Today 25 Years Agreement Term Length (3.5% annual increase in monthly bill) $153 Monthly Bill for Year One (plus taxes, if applicable; includes $7.50 discount for Auto-Pay enrollment) $0.244 Year 1 Cost per kWh (excluding upfront payment, if any) WE’VE GOT YOU COVERED WITH OUR WORRY-FREE SERVICE We provide hassle-free design, permitting, and installation. We monitor the system to ensure it runs properly. We warrant, insure, maintain and repair the system. We also provide a 10- year roof warranty. Selling your home? We guarantee the buyer will qualify to assume your agreement. A SOLAR SYSTEM DESIGN FOR YOUR HOME You get a 8.97 kW DC Solar System With 23 Solar Panels and 1 Inverter(s) Which will produce an est. 7,526 kWh in its first year And offset approx.105% of your current, estimated electricity usage YOUR SALES REPRESENTATIVE: Jeffrey Montenegro jeffrey.montenegro@sunrun.com DocuSign Envelope ID: B9F670D2-7F1A-4A5E-BCFF-4A8BC7940400 Sunrun Installation Services Inc.|225 Bush Street,Suite 1400,San Francisco,CA 94104 |888.GO.SOLAR |HIC 180120 Contract Version: 2020Q1V1 Generation Date: 1/23/2023 Proposal ID: PK4C1F33C16D-H Version 2020Q1V1 21 By signing below,you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks.Such Agreement shall be the complete understanding between the Parties. SUNRUN INSTALLATION SERVICES INC. Signature:\os\___________________ Print Name:\on\__________________ Date:\od\_______________________ Title:\ot\________________________ Federal Employer Identification Number:26-2841711 IF YOU CHOOSE TO PAY BY CHECK,MAKE CHECKS OUT TO SUNRUN INC.NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE.OUR SALES REPRESENTATIVES ARE NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH EFFECTIVE DATE.PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Customer Primary Account Holder Secondary Account Holder (Optional) \s1\____________________________________\s2\_______________________________ Signature Kenneth Aittaniemi Signature \d1\____________________________________\n2\_______________________________ Date Print Name Email Address*:\em1\ Mailing Address:247 High St Barnstable, MA 02668 Phone:\ph1\ *Email addresses will be used by Sunrun for official correspondence, such as sending monthly bills or other invoices. Sales Consultant By signing below I acknowledge that I am Sunrun accredited,that I presented this agreement according to the Sunrun Code of Conduct,and that I obtained the homeowner's signature on this agreement. \r1\___________________________________________ Signature \r2\___________________________________________ Print Name \r4\___________________________________________ Sunrun ID number DocuSign Envelope ID: B9F670D2-7F1A-4A5E-BCFF-4A8BC7940400 wildclams@comcast.net (508) 654-0543 1/23/2023 2178576981 Jeffrey Montenegro Project Operations Kiffney Hughes 1/23/2023 Stephen A Kelly 695 Myles Standish Blvd Taunton MA 02780 TEL: 978-793-7881 Email: eastmapermits@sunrun.com 50 WOODWIND WAY WEST BARNSTABLE, MA 02668 110004001 AITTANIEMI, RICHARD J TR RICHARD J AITTANIEMI TRUST Property ID: WEST BARNSTABLE, MA 02668 111016 AITTANIEMI, KENNETH J 247 HIGH STREET Property ID: WEST BARNSTABLE, MA 02668 111017 ELDRIDGE, THOMAS S & CASSIA MAIA 19 WOODWIND WAY Property ID: WEST BARNSTABLE, MA 02668 111019 GANNON, JANICE E 235 HIGH STREET Property ID: 240 HIGH STREET WEST BARNSTABLE, MA 02668 111031 DICRESCIO, JACQUELINE TR HAMILTON BARNSTABLE REALTY TRUST Property ID: WEST BARNSTABLE, MA 02668 111032 BASSING, HENRY E & MARY T 254 HIGH ST Property ID: