INSTALLATION OF NEW
ROOF MOUNTED PV SOLAR SYSTEM
42 PACKET LANDING
WEST BARNSTABLE, MA 02668
41.708953,-70.369985
PACKET LANDING
R1 LAYOUT REVISION 4/26/2023
P1 ISSUED TO TOWNSHIP FOR PERMIT 12/22/2022
NO.DESCRIPTION DATE
ELIAS- EILEEN
TRINITY ACCT #: 2022-11-791361
42 PACKET LANDING
WEST BARNSTABLE, MA 02668
41.708953,-70.369985
PROPOSED PV SOLAR SYSTEM
DRAWING DATE:12/22/2022
DRAWN BY:TP
REVISED BY:FJ
DC SYSTEM SIZE:7.6kW
AC SYSTEM SIZE:6kW
MODULE COUNT:19
MODULES USED:HANWHA 400
MODULE SPEC #:Q.PEAK DUO BLK ML-G10.a+ 400
UTILITY COMPANY:EVERSOURCE
UTILITY ACCT #:14499760024
UTILITY METER #:2299272
DEAL TYPE:SUNNOVA
R1
VICINITY MAP
SCALE: NTS Project Title:
System Information:
Drawing Information
Rev. No.Sheet
Issued / Revisions
Project Address:
Drawing Title:
PV - 1
SITE
GENERAL NOTES
IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN "A", PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT.
GENERAL NOTES CONTINUED
14. B)CURRENT PREVAILING UTILITY
COMPANY SPECIFICATIONS, STANDARDS,
AND REQUIREMENTS
15 THIS SET OF PLANS HAVE BEEN PREPARED
FOR THE PURPOSE OF MUNICIPAL AND
AGENCY REVIEW AND APPROVAL. ONCE
APPROVED, THE INSTALLATION
CONTRACTOR IS RESPONSIBLE FOR
INSTALLING ALL SYSTEM COMPONENTS AS
DESCRIBED IN THE DRAWING PACKAGE.
16 ALL INFORMATION SHOWN MUST BE
CERTIFIED PRIOR TO USE FOR
CONSTRUCTION ACTIVITIES.
AMPERE
ALTERNATING CURRENT
ALUMINUM
AMP. FRAME
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMERICAN WIRE GAUGE
CONDUIT (GENERIC TERM OF
RACEWAY, PROVIDE AS SPECIFIED)
COMBINER BOX
CIRCUIT
CURRENT TRANSFORMER
COPPER
DIRECT CURRENT
DISCONNECT SWITCH
DRAWING
ELECTRICAL SYSTEM INSTALLER
ELECTRICAL METALLIC TUBING
FUSIBLE SWITCH
FUSE
GROUND
GROUND FAULT INTERRUPTER
FREQUENCY (CYCLES PER SECOND)
AMP
AC
AL
AF
AFF
AFG
AWG
C
CB
CKT
CT
CU
DC
DISC
DWG
EC
EMT
FS
FU
GND
GFI
HZ
ABBREVIATIONS
JUNCTION BOX
THOUSAND CIRCULAR MILS
KILO-VOLT AMPERE
KILO-WATT
KILO-WATT HOUR
LINE
MAIN CIRCUIT BREAKER
MAIN DISTRIBUTION PANEL
MAIN LUG ONLY
MOUNTED
MOUNTING
NEUTRAL
NATIONAL ELECTRICAL CODE
NOT IN CONTRACT
NUMBER
NOT TO SCALE
OVER CURRENT PROTECTION
POLE
PULL BOX
PHASE
POLY-VINYL CHLORIDE CONDUIT
POWER
QUANTITY
RIGID GALVANIZED STEEL
SOLID NEUTRAL
SWITCHBOARD
TYPICAL
UNLESS OTHERWISE INDICATED
WEATHERPROOF
TRANSFORMER
MOUNT 72 INCHES TO BOTTOM OF
ABOVE FINISHED FLOOR OR GRADE
JB
kCMIL
kVA
kW
kWH
L
MCB
MDP
MLO
MTD
MTG
N
NEC
NIC
NO #
NTS
OCP
P
PB
PH Ø
PVC
PWR
QTY
RGS
SN
JSWBD
TYP
U.O.I.
WP
XFMR
+72
ABBREVIATIONS CONTINUEDGENERAL NOTES
1.THE INSTALLATION CONTRACTOR IS
RESPONSIBLE FOR INSTALLING ALL EQUIPMENT
AND FOLLOWING ALL DIRECTIONS AND
INSTRUCTIONS CONTAINED IN THE DRAWING
PACKAGE AND INFORMATION RECEIVED FROM
TRINITY.
2.THE INSTALLATION CONTRACTOR IS
RESPONSIBLE FOR INSTALLING ALL EQUIPMENT
AND FOLLOWING ALL DIRECTIONS AND
INSTRUCTION CONTAINED IN THE COMPLETE
MANUAL.
3.THE INSTALLATION CONTRACTOR IS
RESPONSIBLE FOR READING AND
UNDERSTANDING ALL DRAWINGS, COMPONENT
AND INVERTER MANUALS PRIOR TO
INSTALLATION. THE INSTALLATION
CONTRACTOR IS ALSO REQUIRED TO HAVE ALL
COMPONENT SWITCHES IN THE OFF POSITION
AND FUSES REMOVED PRIOR TO THE
INSTALLATION OF ALL FUSE BEARING SYSTEM
COMPONENTS.
4.ONCE THE PHOTOVOLTAIC MODULES ARE
MOUNTED, THE INSTALLATION CONTRACTOR
SHOULD HAVE A MINIMUM OF ONE
ELECTRICIAN WHO HAS ATTENDED A SOLAR
PHOTOVOLTAIC INSTALLATION COURSE ON SITE.
5.FOR SAFETY, IT IS RECOMMENDED THAT THE
INSTALLATION CREW ALWAYS HAVE A
MINIMUM OF TWO PERSONS WORKING
TOGETHER AND THAT EACH OF THE
INSTALLATION CREW MEMBERS BE TRAINED IN
FIRST AID AND CPR.
6.THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO BE
INSTALLED FOLLOWING THE CONVENTIONS OF
THE NATIONAL ELECTRICAL CODE. ANY LOCAL
CODE WHICH MAY SUPERSEDE THE NEC SHALL
GOVERN.
7.ALL SYSTEM COMPONENTS TO BE INSTALLED
WITH THIS SYSTEM ARE TO BE "UL" LISTED. ALL
EQUIPMENT WILL BE NEMA 3R OUTDOOR
RATED UNLESS INDOORS.
GENERAL NOTES CONTINUED
8.THE DC VOLTAGE FROM THE PANELS IS
ALWAYS PRESENT AT THE DC DISCONNECT
ENCLOSURE AND THE DC TERMINALS OF THE
INVERTER DURING DAYLIGHT HOURS. ALL
PERSONS WORKING ON OR INVOLVED WITH
THE PHOTOVOLTAIC SYSTEM ARE WARNED
THAT THE SOLAR MODULES ARE ENERGIZED
WHENEVER THEY ARE EXPOSED TO LIGHT.
9.ALL PORTIONS OF THIS SOLAR
PHOTOVOLTAIC SYSTEM SHALL BE MARKED
CLEARLY IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE ARTICLE 690 &
705.
10.PRIOR TO THE INSTALLATION OF THIS
PHOTOVOLTAIC SYSTEM, THE INSTALLATION
CONTRACTOR SHALL ATTEND A
PRE-INSTALLTION MEETING FOR THE REVIEW
OF THE INSTALLATION PROCEDURES,
SCHEDULES, SAFETY AND COORDINATION.
11.PRIOR TO THE SYSTEM START UP THE
INSTALLATION CONTRACTOR SHALL ASSIST IN
PERFORMING ALL INITIAL HARDWARE
CHECKS AND DC WIRING CONDUCTIVITY
CHECKS.
12.FOR THE PROPER MAINTENANCE AND
ISOLATION OF THE INVERTERS REFER TO THE
ISOLATION PROCEDURES IN THE OPERATION
MANUAL.
13.THE LOCATION OF PROPOSED ELECTRIC AND
TELEPHONE UTILITIES ARE SUBJECT TO FINAL
APPROVAL OF THE APPROPRIATE UTILITY
COMPANIES AND OWNERS.
14.ALL MATERIALS, WORKMANSHIP AND
CONSTRUCTION FOR THE SITE
IMPROVEMENTS SHOWN HEREIN SHALL BE
IN ACCORDANCE WITH:
A)CURRENT PREVAILING MUNICIPAL
AND/OR COUNTY SPECIFICATIONS,
STANDARDS AND REQUIREMENTS
SHEET INDEX
COVER SHEET W/ SITE INFO & NOTES
ROOF PLAN W/ MODULE LOCATIONS
ELECTRICAL 3 LINE DIAGRAM
APPENDIX
PV-1
PV-2
PV-3
AP
R
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
ROOF 1
MODULES: 0 PITCH: 5°
ORIENTATION: 299°
ROOF 2 MODULES: 7 PITCH: 30 ORIENTATION: 119
ROOF 3 MODULES: 0
PITCH: 30° ORIENTATION: 299°
ROOF 4
MODULES: 0 PITCH: 30°
ORIENTATION: 299°
ROOF 5 MODULES: 8 PITCH: 30
ORIENTATION: 119
ROOF 6 MODULES: 4 PITCH: 30 ORIENTATION: 209
ROOF 7 MODULES: 0
PITCH: 30° ORIENTATION: 29°NS270
9013522545315
R4
R3
R2
R5
R1
R6 R7
FRONT
BACK
DC
AC
DTS
ep M19'-3"SOLAR MODULES SHALL NOT
EXCEED PEAK HEIGHT.
HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF
SCALE: NOT TO SCALE
ATTACHMENT & CLIP DETAIL
SCALE: NOT TO SCALE 6"MAXSOLAR MODULE
EXISTING RAFTER
(REFER TO ENGINEERS LETTER FOR SPECS)
ECOFASTEN "L" FOOT
(REFER TO SPEC SHEET FOR DETAILS)
SOLAR MODULE
ECOFASTEN CLAMP
(REFER TO SPEC SHEET FOR DETAILS)
PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF
SCALE: NOT TO SCALE
APOC SEALANT
EXISTING ASPHALT SHINGLES
(REFER TO ENGINEERS LETTER FOR SPECS)
S.S. LAG BOLT
(REFER TO ENGINEERS LETTER FOR SPECS)
ECOFASTEN FLASHING
(REFER TO SPEC SHEET FOR DETAILS)
ECOFASTEN RAIL
(REFER TO SPEC SHEET FOR DETAILS)
NEW PV SOLAR MODULE, TYPICAL
(REFER TO EQUIPMENT SCHEDULE FOR
SPECS AND QUANTITIES)
NEW ECOFASTEN RAIL,TYPICAL
TO BE MOUNTED PERPINDICULAR TO
STRUCTURE(REFER TO ECOFASTEN
SPECIFICATION / DATA SHEET FOR DETAILS )
NEW MOUNTING FOOT/ ATTACHMENT
POINTS, TYPICAL (REFER TO
ENGINEERING LETTER FOR SPACING AND
DETAILS)
NEW END CLIP, TYPICAL
(REFER TO ECOFASTEN SPECIFICATION /
DATA SHEET FOR DETAILS )
NEW MID CLIP, TYPICAL
(REFER TO ECOFASTEN SPECIFICATION /
DATA SHEET FOR DETAILS )
NOTES : *REFER TO MODULE SPECS FOR MODULE DIMENSIONS
*DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE
41.708953,-70.369985
19 HANWHA 400 (Q.PEAK DUO BLK ML-G10.a+ 400)
1 SE6000H-US000BEi4
INDICATES NEW PRODUCTION METER TO BE INSTALLED
INDICATES NEW INVERTER TO BE
INSTALLED
REFER TO EQUIPMENT SCHEDULE FOR SPECS
INDICATES EXISTING ELECTRICAL PANEL LOCATION:
INSIDE OUTSIDE.
OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE.
R1 LAYOUT REVISION 4/26/2023
P1 ISSUED TO TOWNSHIP FOR PERMIT 12/22/2022
NO.DESCRIPTION DATE
ELIAS- EILEEN
TRINITY ACCT #: 2022-11-791361
42 PACKET LANDING
WEST BARNSTABLE, MA 02668
41.708953,-70.369985
PROPOSED PV SOLAR SYSTEM
DRAWING DATE:12/22/2022
DRAWN BY:TP
REVISED BY:FJ
DC SYSTEM SIZE:7.6kW
AC SYSTEM SIZE:6kW
MODULE COUNT:19
MODULES USED:HANWHA 400
MODULE SPEC #:Q.PEAK DUO BLK ML-G10.a+ 400
UTILITY COMPANY:EVERSOURCE
UTILITY ACCT #:14499760024
UTILITY METER #:2299272
DEAL TYPE:SUNNOVA
R1
Project Title:
System Information:
Drawing Information
Rev. No.Sheet
Issued / Revisions
Project Address:
Drawing Title:
PV - 2
NOTES:
1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
2.) ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION.
3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION.
4.)AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S )NEC 690.13(E).
5.)ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING.
6.)ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE.
SYMBOL LEGEND EQUIPMENT SCHEDULE
QTY SPEC #
EQUIPMENT SCHEDULE
ARRAY SCHEDULE
PLUMBING SCHEDULE
OTHER OBSTRUCTIONS
M
UD
INDICATES EXISTING METER LOCATION
INDICATES ROOF DESIGNATION . REFER TO
ARRAY SCHEDULE FOR MORE INFORMATION
INDICATES NEW PV SOLAR MODULE. RED MODULES
INDICATE PANELS THAT USE MICRO INVERTERS. REFER
TO EQUIPMENT SCHEDULE FOR SPECS.
R1 SP INDICATES NEW PV ONLY SUBPANEL
TO BE INSTALLED
INDICATES NEW UNFUSED PV DISCONNECT TO BE
INSTALLED OUTSIDE (UTILITY ACCESSIBLE )
P
DC
AC
ep
D INDICATES NEW 0 TO BE INSTALLED
DC INDICATES NEW DC DISCONNECT R
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
SD INDICATES EXISTING SERVICE DISCONNECT
TS INDICATES EXISTING TRANSFER SWITCH
(PROPERTY LINE )
FRONT
BACK
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS
REQUIRED CONDUCTOR AMPACITY PER STRING
[NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A
AWG #10, DERATED AMPACITY
AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96
RACEWAY DERATING = 4 CCC: 0.80
(40*.96)0.80 = 30.72A
30.72A >_ 18.75A, THEREFORE WIRE SIZE IS VALID
TOTAL AC REQUIRED CONDUCTOR AMPACITY
25.00A*1.25 = 31.25A
AWG #8, DERATED AMPACITY
AMBIENT TEMP: 30°C, TEMP DERATING: 1.0
RACEWAY DERATING <_ 3 CCC: N/A
55A*1.0 = 55A
55A >_ 31.25A, THEREFORE AC WIRE SIZE IS VALID
CALCULATION FOR PV OVERCURRENT PROTECTION
TOTAL INVERTER CURRENT: 25.00A
25.00A*1.25 = 31.25A
--> 40A OVERCURRENT PROTECTION IS VALID
ARRAY CIRCUIT WIRING NOTES
1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY
FOR DETERMINING ONSITE CONDITIONS AND
EXECUTING INSTALLATION IN ACCORDANCE WITH
NEC 2020
2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON
ASHRAE MINIMUM MEAN EXTREME DRY BULB
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT
TEMP = -16°C
3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED
ON ASHRAE HIGHEST MONTH 2% DRY BULB
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP =
33°C
4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN
TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED
STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9
CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED
SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING
THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS
(ALL OF UNITED STATES)
5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS
SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT
CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH
NEC 690.12(A) THROUGH (D)
6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED
TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC
SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41 (A)(4)
7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE
IDENTIFIED WITH THE FOLLOWING OUTER FINISH:
POSITIVE CONDUCTORS = RED
NEGATIVE CONDUCTORS = BLACK
NEC 210.5(C)(2)
8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV
WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE
PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT
SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL
CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND
WHERE EXPOSED TO DIRECT SUNLIGHT SHALL
CONTAIN ≤ 9 CURRENT CARRYING CONDUCTORS.
9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS
OTHERWISE NOTED
10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON
ROOFTOP AND SHALL BE LIMITED TO 12” IF USED
OUTDOORS
11.)OVERCURRENT PROTECTION FOR CONDUCTORS
CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE
LOCATED WITHIN 10' OF THE POINT OF CONNECTION NEC
690.9(A)(3)(2)
12.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A
UTILITY AND THE OTHER AN INVERTER, PV BACKFEED
BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY
NEC 705.12(B)(3)(2)
13.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY
GENERATION CIRCUITS AND NO UNUSED POSITIONS OR
LOADS
14.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE
A NEMA 3R RATING
NOTE:
INTERNAL REVENUE GRADE MONITORING
CONTAINED WITHIN SOLAR EDGE INVERTER
SOLAR EDGE PN. RWND-3D-240-MB
E
INVERTER #1 - SE6000H-US000BEi4
DC AC
Imp 16.5 Pout 6000
Vmp 380 Imax 25
Voc 480 OCPDmin 31.25
Isc 30 Vnom 240
PV MODULE SPECIFICATIONS
HANWHA 400 (Q.PEAK DUO BLK ML-G10.a+ 400)
Imp 10.77
Vmp 37.13
Voc 45.3
Isc 11.14
A #6 THWN-2 GEC TO EXISTING GROUND ROD
B 3/4'' CONDUIT W/ 2-#8 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND
C 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND
D 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND
E 3/4'' CONDUIT W/ 2-#8 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND
F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY
G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2, 1-#8 THWN-2 GROUND
NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR
TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS
INVERTER #1
PV+L1 L2 N PV-D
SOLAR MODULES MOUNTED TO ROOF ON 3 ARRAYS
19 - 400W MODULES W/ 1 SOLAR EDGE S440 PER MODULE
15 ADC MAX PER STRING
1 STRING OF 10 MODULES IN SERIES - 380 Vmax
1 STRING OF 9 MODULES IN SERIES - 380 Vmax
*2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1
f 8"x8"
JUNCTION
BOX
NEW PVC
TAP BOX
INSULATED LINE
TAPS TO BE
INSTALLED ON
MAIN FEEDERS
NEC 705.12(A)
EXISTING
MAIN BREAKER LOAD CENTERNEUTRAL2p100AMAIN240V1Ø
EXISTING
120/240V
UTILITY
METER
EXISTING
GENERATOR
M
NEUTRAL2P100A
G
EXISTING
MAIN BREAKER LOAD CENTER
EXISTING
GENERATOR TRANSFER SWITCH
100A MAIN BREAKER
100A BUSBAR
LOCKABLE 60A DISCONNECT
FUSED W/ 40A FUSES
SQUARE D
PN: D222NRB
ISOLATED NEUTRAL
240V 1Ø
G
R1 LAYOUT REVISION 4/26/2023
P1 ISSUED TO TOWNSHIP FOR PERMIT 12/22/2022
NO.DESCRIPTION DATE
ELIAS- EILEEN
TRINITY ACCT #: 2022-11-791361
42 PACKET LANDING
WEST BARNSTABLE, MA 02668
41.708953,-70.369985
PROPOSED PV SOLAR SYSTEM
DRAWING DATE:12/22/2022
DRAWN BY:TP
REVISED BY:FJ
DC SYSTEM SIZE:7.6kW
AC SYSTEM SIZE:6kW
MODULE COUNT:19
MODULES USED:HANWHA 400
MODULE SPEC #:Q.PEAK DUO BLK ML-G10.a+ 400
UTILITY COMPANY:EVERSOURCE
UTILITY ACCT #:14499760024
UTILITY METER #:2299272
DEAL TYPE:SUNNOVA
R1
Project Title:
System Information:
Drawing Information
Rev. No.Sheet
Issued / Revisions
Project Address:
Drawing Title:
PV - 3
Engineer / License Holder:
R
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
JOB NAME:ELIAS- EILEEN
ADDRESS:42 Packet Landing
West Barnstable, MA 02668
41.708953,-70.369985
42.28 ESTIMATED PERSONNEL HOURS 1.76 DAYS 1.32 DAYS 0.88 DAYS
•19 HANWHA 400's (7.6KW)(CREW OF 3)(CREW OF 4)(CREW OF 6)
•3 SEPARATE ARRAYS
•19' PEAK TO GROUND
•15 PORTRAIT & 4 LANDSCAPED
•1 INVERTERS INSTALLED OUTSIDE
•NO TRENCH
ESTIMATED SENT TO JOB USED
□HANWHA 400 (Q.PEAK DUO BLK ML-G10.a+ 400)19 ______
□S440 SE OPTIMIZERS 19 ______
□SE6000H-US000BEi4 1 ______
□60A OUTDOOR FUSED DISCONNECT W/ (2) 40A FUSES 1 ______
□60A OUTDOOR NON-FUSED DISCONNECT 1 ______
□SOLADECK BOX(ES) & HAYCO CONNECTOR(S)3 ______
□PV LEAD WIRE 100'______
□INSULATED BUG BITES (LINE TAPS)2 ______
□CASE(S) OF BLACK SPRAY PAINT 1 ______
□CASE(S) OF TAR 1 ______
□ECOFASTEN 2012025 CF STD RAIL MLL AL 171.5 13 ______
□ECOFASTEN 2012013 CF RAIL SPLICE 5 ______
□ECOFASTEN 2099017 CF END CLAMP 32MM BLK 24 ______
□ECOFASTEN 2099022 CF MID CLAMP SHORT BLK 26 ______
□ECOFASTEN 4011011 MODULE JUMPER 3 ______
□GROUNDING LUG (NOT PROVIDED BY ECOFASTEN)3 ______
□ECOFASTEN 2012022 CF UNIV L-FOOT MLL 3 53 ______
□ECOFASTEN 3012020 GF-1 FLASHING GLV BLK 8 x 10 53 ______
□ECOFASTEN 2012019 CF MLPE MOUNT 19 ______
□ECOFASTEN 2012020 CF WIRE MGMT CLIP 19 ______
□ECOFASTEN 2012024 CF END CAP 24 ______
MATERIAL LIST
R(FOR INTERNAL USE ONLY)
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
INSTALLATION OF NEW
ROOF MOUNTED PV SOLAR SYSTEM
42 PACKET LANDING
ELIAS- EILEEN
42 PACKET LANDING
WEST BARNSTABLE, MA 02668
41.708953,-70.369985
R
APPENDIX
CONTENTS
LABELS, STICKERS, AND PLACARDS
EQUIPMENT DATA SHEETS
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
12218 HOLMES LANE
KANSAS CITY, MO 64146
179001002
WARDON PATCHER REALTY TRUST
C/O PATRICIA GRAY
Property ID:
BRIGHTON, MA 02135-1505
179003
CRAWFORD, EDWARD F & MARGARET M
12 MATCHETT STREET
Property ID:
42 PACKET LANDING WAY
WEST BARNSTABLE, MA 02668
179004
ELIAS, STANLEY & EILEEN TRS
ELIAS FAMILY REVOCABLE TRUST
Property ID:
COTUIT, MA 02635
179015
ROBINSON, ANDREW M
150 POINT ISABELLA ROAD
Property ID:
12218 HOLMES LANE
KANSAS CITY, MO 64146
179016
WARDON PATCHER REALTY TRUST
C/O CHERYL GRAY
Property ID: