Loading...
HomeMy WebLinkAbout2019 NOID Full Dormers Delay ImposedFIRST FLOOR PLAN DESIGNER OF ANY ERRORS OR OMISSIONS. THESE DRAWINGS ARE SOLELY FOR THE USE ACT OF 1990. ARCHITECTURAL COPYRIGHT PROTECTION THESE DRAWINGS REQUIRES THE WRITTEN CONSENT OF THE DESIGNER UNDER THE OF THE OWNER NOTED. ANY OTHER USE OF COMMENCES WITHOUT NOTIFYING THE IN THESE DRAWINGS IF CONSTRUCTION WILL BE RESPONSIBLE FOR THE CONTENT THESE DRAWINGS PRIOR TO START OF ERRORS OR OMISSIONS ARE FOUND ON THE DESIGNER SHALL BE NOTIFIED IF ANY CONSTRUCTION. THE BUILDING CONTRACTOR COTUIT BAY DESIGN, LLC 43 BREWSTER ROAD MASHPEE ,MA. 02649 FAX (508) 539-9402 PH. (508) 274-1166 101 EDGEHILL ROAD HYANNISPORT, MA KENNEDY RESIDENCE NEW ADDITION/REMODELING PLAN FOR: A1 DRAWING NO. :SCALE : 1/4" = 1'-0" 1/11/2019 DATE : CONSTRUCTION TO BE REMOVED NEW CONSTRUCTION LEGEND: EXISTING WALLS LIVING UP53'-7"28'-0"14'-5"12'-0"22'-8"4'-6"20'-6"7'-6" DINING KITCHEN UP STUDY EXIST. DECK EXIST. SECOND FLOOR PLAN BEDROOM #153'-7"28'-0" UP BEDROOM #3 ASSUMED BEAM BEAM ABOVEBATH CLOS. DN.53'-7"HALL BEDROOM #5 BATH #1 BEDROOM #4 ENTRY E N S W BEDROOM #2 CARBON MONOXIDE DETECTOR SMOKE DETECTOR COVERED PORCH BATH #5 NAILING SCHEDULE NO. OF BOX NAILS 8d1/2" & 25/32" FIBERBOARD PANELS 1/2" GYPSUM WALLBOARD 1" OR LESS THICKNESS WOOD STRUCTURAL PANELS (PLYWOOD) GREATER THAN 1" THICKNESS FLOOR SHEATHING: 5d 8d 10d 110 MPH EXPOSURE B WIND ZONE LEDGER STRIP TO BEAM OR GIRDER (FACE NAILED) GABLE END WALL RAKE OR RAKE TRUSS W/ LOOKOUT BLOCKS GABLE END WALL RAKE OR RAKE TRUSS W/O OVERHANG JOIST TO SILL, TOP PLATE OR GIRDER (TOE NAILED) JOIST ON LEDGER TO BEAM (TOE NAILED) RAFTERS OR TRUSSES SPACED UP TO 16" o.c. WOOD STRUCTURAL PANELS (PLYWOOD) BAND JOIST TO SILL OR TOP PLATE (TOE NAILED0 RAFTERS OR TRUSSES SPACED OVER 16" o.c. BAND JOIST TO JOIST (END NAILED) ROOF SHEATHING: GYPSUM WALLBOARD W/ STRUCTURAL OUTLOOKERS CEILING SHEATHING: STUDS SPACED UP TO 24" o.c. WOOD STRUCTURAL PANELS (PLYWOOD) GABLE END WALL RAKE OR RAKE TRUSS WALL SHEATHING: JOINT DESCRIPTION TOP PLATES AT INTERSECTIONS (FACE NAILED) BLOCKING TO RAFTER (TOE NAILED) RIM BOARD TO RAFTER (END NAILED) BLOCKING TO SILL OR TOP PLATE (TOE NAILED) BLOCKING TO JOISTS (TOE NAILED) HEADER TO HEADER (FACE NAILED) STUD TO STUD (FACE NAILED) WALL FRAMING: FLOOR FRAMING: ROOF FRAMING: 3-8d 5d 8d 8d 8d 8d 8d 8d 2- 16 d 3-16d NO. OF COMMON NAILS 2-8d 3-16d 3-16d 4-8d 2- 16 d 16d 4-16d 2- 16 d 2- 8d ----3" EDGE/6" FIELD 6" EDGE/12" FIELD 6" EDGE/6" FIELD 7" EDGE/10" FIELD 10d 16d ---- PER JOIST3-10d PER FOOT PER JOIST 4" EDGE/4" FIELD 7" EDGE/10" FIELD 6" EDGE/6" FIELD 6" EDGE/6" FIELD 6" EDGE/6" FIELD 4" EDGE/4" FIELD 6" EDGE/12" FIELD 10d ---- 10d 10d 10d 10d 10d 3- 16d 4-16d EACH END AT JOINTS EACH END EACH END PER JOIST EACH JOIST NAIL SPACING 16" o.c. ALONG EDGES EACH BLOCK 2-10d 4-16d 4-16d 4-10d 2-16d 16d 5-16d 24" o.c. 3- 16d 2- 10d DURING FRAMING CONSTRUCTION INSTALLER/CONTRACTOR. TIMBER FRAMING TO BE SPRUCE/PINE/FIR NO. 2 GRADE FOLLOW ALL REQUIREMENTS OF THE IECC2015 RESIDENTIAL ENERGY EFFICIENCY REQUIREMENTS & VERIFY ALL DETAILS WITH THE INSULATION 13.) 12.) 11.) 110 MPH EXPOSURE B WIND ZONE 2.) CONTRACTOR TO VERIFY ALL INTERIOR & EXTERIOR MATERIALS, 1.) CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS ALL CONSTRUCTION TO CONFORM TO 780 CMR MASSACHUSETTS STATE BUILDING CODE, 9TH EDITION AMENDEMENT & IRC2015 ALL CONCRETE USED FOR FOUNDATION WALLS, FOOTINGS & SLABS ALL SHEETS OF PLYWOOD WALL SHEATHING TO BE INSTALLED VERTICALLY, FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF VERIFY ALL PLUMBING & ELECTRICAL DETAILS W/ OWNERS ON THE SITE OR HORIZONTALLY W/ BLOCKING AT EDGES, 3"EDGE/12" FIELD NAILING NOTES: FIRST FLOOR TO BE 6'-10" ABOVE SUBFLOOR 3.) ROUGH OPENING HEAD HEIGHT OF WINDOWS AT DETAILS, & FINISHES IN THE FIELD WITH OWNER & DIMENSIONS IN THE FIELD ALL LVL LUMBER/BEAMS TO BE 1.9e L/360 LOAD ALL SIMPSON COMPONENTS TO BE 3000 PSI 8.) 9.) 10.) 5.) 6.) 7.) 4.) ALL HEADERS TO BE 2- 2 x 6's UNLESS OTHERWISE NOTED 14.)THIS STRUCTURE IS DESIGNED TO THE AF&PA WOOD FRAME CONSTRUCTION MANUAL FOR 110 MPH EXPOSURE "B" LOCATION PER SECTION R301.2.1.1 BASEMENT WALL IECC2015 RESIDENTIAL ENERGY EFFICIENCY DETAILS 2. 15/19 MEANS R=15 CONTINUOUS INSULATED SHEATHING ON THE INTERIOR OR EXTERIOR OF THE HOME OR R=19 INSULATION CAVITY AT THE INTERIOR OF THE BASEMENT WALL 3. REFER TO IECC 2015 CHAPTER 4 FOR ALL INSULATION & ENERGY REQUIREMENTS TABLE 402.1.2 (MINIMUM PRESCRIPTIVE INSULATION & FENESTRATION REQUIREMENTS) CLIMATE ZONE 5 (USE EITHER PRESCRIPTIVE VALUES OR RESCHECK CALCULATION NOTES: 1. R-VALUES ARE MINIMUMS & U-FACTORS ARE MAXIMUMS. U-FACTOR SKYLIGHTFENESTRATION U-FACTOR 0.30 0.55 WOOD FRAMED WALLCEILING R-VALUE 49 R-VALUE 20 or 13 + 5 R-VALUE 30 FLOOR R-VALUE 15/19 R-VALUE CRAWL SPACE WALLBASEMENT SLAB 10 (4 FT. DEEP) R-VALUE 15/19 4. 13 + 5 MEANS R5 CONTINUOUS INSULATED SHEATHING ON THE WALL EXTERIOR & R13 CAVITY INSULATION MASS. AMMEND. 28'-0" A2 A A2 A A2 A A2 A STACK W/D 10'-2" 10'-2" CLOS.CLOS.CLOS.CLOS.15'-11"13'-2" 13'-10"14'-3"1'-0"BATH #2 BATH #3BATH #4 LIN. CLOS. HALL 13'-10"14'-2" PRELIMINARY DRAWING NOT FOR CONSTRUCTION (VAULTED) 60" VANITY 7'-8 1/2"7'-8 1/2"NORTH ELEVATION WEST ELEVATION DESIGNER OF ANY ERRORS OR OMISSIONS. THESE DRAWINGS ARE SOLELY FOR THE USE ACT OF 1990. ARCHITECTURAL COPYRIGHT PROTECTION THESE DRAWINGS REQUIRES THE WRITTEN CONSENT OF THE DESIGNER UNDER THE OF THE OWNER NOTED. ANY OTHER USE OF COMMENCES WITHOUT NOTIFYING THE IN THESE DRAWINGS IF CONSTRUCTION WILL BE RESPONSIBLE FOR THE CONTENT THESE DRAWINGS PRIOR TO START OF ERRORS OR OMISSIONS ARE FOUND ON THE DESIGNER SHALL BE NOTIFIED IF ANY CONSTRUCTION. THE BUILDING CONTRACTOR COTUIT BAY DESIGN, LLC 43 BREWSTER ROAD MASHPEE ,MA. 02649 FAX (508) 539-9402 PH. (508) 274-1166 101 EDGEHILL ROAD HYANNISPORT, MA KENNEDY RESIDENCE NEW ADDITION/REMODELING PLAN FOR: A2 DRAWING NO. :SCALE : 1/4" = 1'-0" 1/11/2019 DATE : PRELIMINARY DRAWING NOT FOR CONSTRUCTION 12 4 12 8 12 4 7'-8 1/2"7'-8 1/2"SOUTH ELEVATION 12 4 12 8 EAST ELEVATION 7'-8 1/2"7'-8 1/2"12 12