Loading...
HomeMy WebLinkAbout20220429_NOI_NE Wind Barnstable Part 5WWW W W WWWWWWWWWG12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-GGGGGGGGGGGG G SERVICE ROAD(ROUTE 6 WEST )MID CAPE HWYMID CAPE HWY(ROUTE 6 EAST)M A T C H L I N E S E E S H E E T 1 0 35 331+00332+00333+00334+00 335+00 336+00 337+00 338+00 339+00 340+00 341+00 342+00 342+65 PARCEL 214-001 B-129 B-128 B-130 B-131 B-132 03 04 05 06 07 08 09 10 11 1213 WWW W W WWWWWWWWWG12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-G12-GGGGGGGGGGGG G SERVICE ROAD(ROUTE 6 WEST )MID CAPE HWYMID CAPE HWY(ROUTE 6 EAST)M A T C H L I N E S E E S H E E T 1 0 35 331+00332+00333+00334+00 335+00 336+00 337+00 338+00 339+00 340+00 341+00 342+00 342+65 PARCEL 214-001 B-129 B-128 B-130 B-131 B-132 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK LEGEND: 20 SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585431\new england wind pcw duct bank only - 100 scale2022.04.08 1:00:30 PMmillington, dylanby:B C D E F 100 SCALE: 1" = 100' 0 200 300 400 100 SCALE: 1" = 100' 0 200 300 400 PROPOSED DUCT BANK LAYOUT WEST BARNSTABLE SUBSTATION WEST BARNSTABLE SUBSTATION JACKING SHAFT 30'x30' INSIDE / 35'x35' OUTSIDE (APPROX.) RECEIVING SHAFT 24'x15' INSIDE / 29'x20' OUTSIDE (APPROX) ALTERNATIVES FOR THE ROUTE 6 CROSSING ARE BEING EVALUATED SEPARATELY FROM THE DUCT BANK ROUTE ALTERNATIVES FOR THE ROUTE 6 CROSSING ARE BEING EVALUATED SEPARATELY FROM THE DUCT BANK ROUTE NOTE: ANY ABOVE AND BELOW GROUND UTILITY CONFLICTS TO BE COORDINATED WITH THE RESPECTIVE UTILITY COMPANY DURING FINAL DESIGN SURVEYED PARCEL BOUNDARY JACKING SHAFT 30'x30' INSIDE / 35'x35' OUTSIDE (APPROX.) SURVEYED PARCEL BOUNDARY RECEIVING SHAFT 24'x15' INSIDE / 29'x20' OUTSIDE (APPROX) VAULT 5ASTA = 84+38 78+0079+0080+0081+0082+008 3 + 0 0 8 4 + 0 0 8 5+ 0 0 8 6+ 0 0 OLD STAGE RDFALMOUTH RDFALMOUTH RD CAMP OPECHEE RD0 SCALE: 1" = 40' 40 160100 MAINTAIN DRIVEWAY ACCESS AT ALL TIMES 200' W20-5cR MA-R2-10a MA-R2-10e 500' FROM WORK ZONE 250' W20-1c W20-5cL 250'80'2 5 0 ' W20-1c W5-1 MA-W20-7b REFLECTORIZED DRUMS (SPACED @ 25' O.C.) MA-R2-10a REFLECTORIZED DRUMS (SPACED @ 25' O.C.) MA-R2-10aMA-W20-7b W20-1c MA-R2-10e 500' FROM WORK ZONE 500'250'250'W20-1c MA-R2-10a MA-W20-7b MAINTAIN DRIVEWAY ACCESS AT ALL TIMES PEDESTRIAN CROSSING APPEARS DISUSED MA-R2-10e 500' FROM WORK ZONE FALMOUTH RD TMP SHEET 1 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - tmp2022.04.14 11:52:42 AMmillington, dylanby:B C D E F R4-7 5 0 0 ' 2 5 0 ' 500' MA-R2-10e 500' FROM WORK ZONE 250'100' 500'250' 250' MA-W20-7b 36"x36" R4-7 24"x30" MA-R2-10a 48"x36" MA-R2-10e 36"x48" W20-1c 36"x36" SIGN LEGEND W20-5cR 36"x36" W5-1 36"x36" W12-1 30"x30" W12-1 5 0 0 ' P/F LEGEND REFLECTORIZED PLASTIC DRUM OR 36" CONE POLICE DETAIL TYPE III BARRICADE WORK ZONE DIRECTION OF TRAFFIC SIGN ARROW BOARD PORTABLE CHANGEABLE MESSAGE SIGN W20-5cL 36"x36" MA-W20-7b COVER EXISTING R3-7L COVER EXISTING R3-7L R3-7R R3-7L 30"x30" R3-7R 30"x30" VAULT 5A STA = 84+38 78+0079+0080+0081+0082+008 3 + 0 0 8 4 + 0 0 8 5 + 0 0 8 6+00OLD STAGE RDFALMOUTH RDFALMOUTH RD CAMP OPECHEE RD0 SCALE: 1" = 40' 40 160100 FALMOUTH RD TMP SHEET 2 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - tmp2022.04.14 11:52:49 AMmillington, dylanby:B C D E F P/F LEGEND REFLECTORIZED PLASTIC DRUM OR 36" CONE POLICE DETAIL TYPE III BARRICADE WORK ZONE DIRECTION OF TRAFFIC SIGN ARROW BOARD PORTABLE CHANGEABLE MESSAGE SIGN MA-W20-7b 36"x36" R4-7 24"x30" MA-R2-10a 48"x36" MA-R2-10e 36"x48" W20-1c 36"x36" SIGN LEGEND R4-8 24"x30" 50' REFLECTORIZED DRUMS (SPACED @ 25' O.C.) MAINTAIN DRIVEWAY ACCESS AT ALL TIMES 500'250' W20-1cMA-W20-7bR3-7L MA-W4-7R 150' SHIFT 250' REFLECTORIZED DRUMS (SPACED @ 25' O.C.) W5-1 36"x36"W12-1 30"x30" 500' MA-W4-7R 36"x36" MA-R2-10a MAINTAIN DRIVEWAY ACCESS AT ALL TIMES 80'2 5 0 ' W20-1c W5-1 REFLECTORIZED DRUMS (SPACED @ 25' O.C.) MA-R2-10a 5 0 0 ' 2 5 0 ' MA-R2-10e 500' FROM WORK ZONE W12-1 500'250'250'MA-R2-10a MA-W20-7b W20-1c R4-7 R4-8 100'245' TAPER500' W4-2LW20-5cL MA-R2-10a W20-1c 250'500'250' MA-W20-7b MA-R2-10e 500' FROM WORK ZONE MA-R2-10e 500' FROM WORK ZONE MA-R2-10e 500' FROM WORK ZONE W4-2L 36"x36" MA-W20-7b 5 0 0 ' R3-7L 30"x30" W20-5cL 36"x36" R3-7R 30"x30" COVER EXISTING R3-7L COVER EXISTING R3-7L R3-7R VAULT 5A STA = 84+38 78+0079+0080+0081+0082+008 3 + 0 0 8 4 + 0 0 8 5 + 0 0 8 6+00OLD STAGE RDFALMOUTH RDFALMOUTH RD CAMP OPECHEE RD0 SCALE: 1" = 40' 40 160100 FALMOUTH RD TMP SHEET 3 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - tmp2022.04.14 11:52:53 AMmillington, dylanby:B C D E F P/F LEGEND REFLECTORIZED PLASTIC DRUM OR 36" CONE POLICE DETAIL TYPE III BARRICADE WORK ZONE DIRECTION OF TRAFFIC SIGN PORTABLE CHANGEABLE MESSAGE SIGN R4-8 MAINTAIN DRIVEWAY ACCESS AT ALL TIMES MAINTAIN PEDESTRIAN ACCESS WITH POLICE ASSISTANCE MA-R2-10e 500' FROM WORK ZONE MA-R2-10e 500' FROM WORK ZONE MA-R2-10e 500' FROM WORK ZONE MAINTAIN DRIVEWAY ACCESS AT ALL TIMES 80'2 5 0 ' W20-1c W5-1 REFLECTORIZED DRUMS (SPACED @ 25' O.C.) MA-R2-10a 5 0 0 ' 2 5 0 ' MA-R2-10e 500' FROM WORK ZONE W12-1 MA-W20-7b 36"x36" MA-R2-10a 48"x36" MA-R2-10e 36"x48" W20-1c 36"x36" SIGN LEGEND R4-8 24"x30" W5-1 36"x36" R3-8(L-T-R) 48"x30" W12-1 30"x30"500'250'250'MA-R2-10a MA-W20-7b W20-1c 215'500'250' R3-8(L-T-R)MA-W20-7b MA-R2-10a W20-1c 250' 500'250' MA-R2-10a MA-W20-7bW20-1c 250' MA-W20-7b 5 0 0 ' COVER EXISTING R3-7L COVER EXISTING R3-7L R3-7R R3-7L 30"x30" R3-7R 30"x30" VAULT 5A STA = 84+38 78+0079+0080+0081+0082+008 3 + 0 0 8 4 + 0 0 8 5 + 0 0 8 6+00OLD STAGE RDFALMOUTH RDFALMOUTH RD CAMP OPECHEE RD0 SCALE: 1" = 40' 40 160100 FALMOUTH ROAD TMP SHEET 4 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - tmp2022.04.14 11:52:59 AMmillington, dylanby:B C D E F P/F LEGEND REFLECTORIZED PLASTIC DRUM OR 36" CONE POLICE DETAIL TYPE III BARRICADE WORK ZONE DIRECTION OF TRAFFIC SIGN PORTABLE CHANGEABLE MESSAGE SIGN 2 5 0 ' W20-1c W20-5cR MA-R2-10a 2 5 0 ' MA-W20-7b 36"x36" MA-R2-10a 48"x36" MA-R2-10e 36"x48" W20-1c 36"x36" SIGN LEGEND W20-5cR 36"x36" W4-2R 36"x36" 8 0 ' 5 0 0 ' W4-2R MAINTAIN DRIVEWAY ACCESS AT ALL TIMES MA-R2-10e 500' FROM WORK ZONE MA-R2-10e 500' FROM WORK ZONE MA-R2-10e 500' FROM WORK ZONE 500'250'250'MA-R2-10a MA-W20-7b W20-1c 500'250' MA-R2-10a MA-W20-7bW20-1c 250' 250' MA-R2-10aMA-W20-7b W20-1c500'250' 9 0 ' TAPER MA-R2-10e 500' FROM WORK ZONE MAINTAIN PEDESTRIAN ACCESS WITH POLICE ASSISTANCE COVER EXISTING R3-7L COVER EXISTING R3-7L R3-7L 30"x30" R3-7R 30"x30" P/F NUMBER OF LANES NUMBER OF STUDIES AVERAGE CAPACITY MEASURED AVERAGE WORK ZONE CAPACITIES LEGEND: NOTES: ROAD TYPE DISTANCE BETWEEN SIGNS ** BA C SUGGESTED WORK ZONE WARNING SIGN SPACING STOPPING SIGHT DISTANCE AS A FUNCTION OF SPEED SPEED* (mph) DISTANCE (ft) SPEED* (km/h) DISTANCE (m) FORMULAS FOR DETERMINING TAPER LENGTHS SPEED LIMIT (S)TAPER LENGTH (L) Meters TYPE OF TAPER TAPER LENGTH (L)* TAPER LENGTH CRITERIA FOR TEMPORARY TRAFFIC CONTROL ZONES SPEED LIMIT (S)TAPER LENGTH (L) FEET W5-1 ROAD NARROWS W30-8R SQUEEZE RIGHT BA 4S (0.8S)BUFFERWORK ZONEBUFFERL/2 B A 4S (0.8S) R4-7 R4-7 50 FT (15m) L/2 W30-8R SQUEEZE RIGHT W5-1 ROAD NARROWS TWO LANE ROAD CENTER OF ROAD CLOSURE WORK ZONE 100FT (30m) MAX. 100FT (30m) MAX. BUFFER 100-150FT (30-45m) W20-7b POLICE OFFICER AHEAD W20-4 W13-1p ONE LANEROADXXX XXM.P.H. W20-4 W13-1p ONE LANEROADXXX XXW20-7b POLICE OFFICER AHEAD P/F OR W20-7 W20-7 OR P/F A B AB M.P.H. TWO LANE ROAD ONE LANE ALTERNATING TRAFFIC 12*1 14 24" (MIN.) REFLECTORIZED DRUM NOT TO SCALE LIMIT OF EXCAVATION TEMPORARY BIT. CONC. PAVEMENT GRAVEL BORROW/SUBBASE EXIST. PAVEMENT LONGITUDINAL DROP-OFF DETAIL TRAVEL WAY WORK AREA DIRECTION OF TRAFFIC W8-3 OR W8-8 OR W8-1 * - INCREASE SLOPE RATIO FOR HIGHER SPEEDS NOT TO SCALE C Depth≥4" LATERAL DROP-OFF DETAIL LATERAL AND LONGITUDINAL DROP-OFF DETAILS TRAFFIC MANAGEMENT PLAN DETAILS SHEET 1 OF 2 -18 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - tmp details2022.04.08 11:24:37 AMmillington, dylanby:B C D E F DOWNSTREAM TAPER: GUIDES TRAFFIC BACK TO ITS ORIGINAL TRAVEL PATH TERMINATION AREA: LETS TRAFFIC RESUME NORMAL OPERATIONS ACTIVITY AREA: WHERE WORK TAKES PLACE TRANSITION AREA: MOVES TRAFFIC OUT OF ITS NORMAL PATH ADVANCE WARNING AREA: TELLS TRAFFIC WHAT TO EXPECT AHEAD LONGITUDINAL BUFFER SPACE LONGITUDINAL BUFFER SPACE: PROVIDES PROTECTION FOR TRAFFIC AND WORKERS = STOPPING SIGHT DISTANCE. NOTHING SHALL BE PLACED/STORED IN BUFFER SPACE SHOULDER TAPER: GUIDES TRAFFIC AWAY FROM SHOULDER/ BREAK-DOWN LANE LATERAL BUFFER SPACE: PROVIDES PROTECTION FOR TRAFFIC AND WORKERS TRAFFIC SPACE: ALLOWS TRAFFIC TO PASS THROUGH THE ACTIVITY AREA WORK SPACE: SET ASIDE FOR WORKERS, EQUIPMENT, AND MATERIAL STORAGE W20-SERIES R2-10a R2-10e B OR C ROADWORKXXX END ROADWORKDOUBLEFINES END WORK ZONES SPEEDINGFINESDOUBLED A THE "A" DISTANCE CAN BE MEASURED FROM THE START OF THE TRAVEL LANE RESTRICTION OR THE SHOULDER/BREAKDOWN LANE RESTRICTION (IF SHOULDER/BREAKDOWN LANE IS ONLY LANE BEING CLOSED) MERGING TAPER LOGITUDINAL BUFFER SPACE (OPT.) SHIFTING TAPER SHIFTING TAPER 4S ft IF S IS IN MPH (0.8S m IF S IS KM/H) DOWNSTREAM TAPER (OPT.) LONGITUDINAL BUFFER SPACE (OPT.) SHIFTING TAPER SHOULDER TAPER LONGITUDINAL BUFFER SPACE (OPT.) L/2 L/3 L L/2 L/2 LATERAL BUFFER SPACE (OPT.) A or B C LEGEND DIRECTION OF TRAVEL CHANNELIZING DEVICE WORK AREA SIGN TYPES OF TAPERS AND BUFFER SPACES SINGLE LANE APPROACH ONE QUADRANT CLOSURE A A A A P W20-7b ONE LANE ALTERNATING TRAFFIC B B W20-4 B B 100 FT (30m) MAX. POLICE OFFICER AHEAD ONE LANEROADXXX W20-4 ONE LANEROADXXX W20-7b POLICE OFFICER AHEAD W20-7b POLICE OFFICER AHEAD W20-4 ONE LANEROADXXX P W20-7b POLICE OFFICER AHEAD W20-4 ONE LANEROADXXX P 100 FT (30m) MAX.100 FT (30m) MAX. * THIS DELINEATION CAN BE REMOVED TO INCREASE CAPACITY OF THE INTERSECTION. POLICE OFFICER CAN BE REMOVED AS WELL P* P B RIGHT LANE MUST TURN RIGHT R3-7R B W20-7b POLICE OFFICER AHEAD W4-7L THRUTRAFFICMERGELEFT W4-2L W20-7b POLICE OFFICER AHEAD W20-7b POLICE OFFICER AHEAD B A L BUFFER L/2 W20-5L LEFTLANECLOSEDXXX A W20-7b POLICE OFFICER AHEAD A A DOUBLE LANE APPROACH HALF ROAD CLOSURE ROADCLOSED R11-2 ROAD CLOSED XX MILES AHEAD LOCAL TRAFFIC ONLY M4-10L R11-3a DETOUR M4-9V ± 200 FT (±60m) ROADCLOSEDXXX W20-3 ROADCLOSEDXXX W20-3 DETOURXXX W20-2 DETOUR DETOUR M4-9L M4-9ALB A DETOUR B A DETOUR ADVANCE SIGNING DETOUR M4-9R DETOUR M4-9L DETOUR M4-9AL DETOUR M4-9V DETOUR M4-9AR DETOUR M4-9V DETOUR M4-9AR DETOUR M4-9R DETOUR M4-9V DETOUR M4-9L DETOUR M4-9R DETOUR M4-9AR ENDDETOUR M4-8a ROADCLOSED R11-2 ROAD CLOSED XX MILES AHEAD LOCAL TRAFFIC ONLY TYPE III BARRICADE ROAD CLOSED R11-2 M4-10R END DETOUR M4-8a DETOUR M4-9L DETOUR M4-9AL DETOURXXX W20-2 DETOUR M4-9L DETOUR M4-9AL R11-3a M4-10L DETOUR DETOUR DETOUR COMPONENT PARTS OF A TEMPORARY TRAFFIC CONTROL (TTC) ZONE SIDEWALK CLOSED CROSS HERE SIDEWALK CLOSED TEMPORARY MARKING FOR CROSSWALK LINES (CR0SS-HATCHING OPTIONAL) 300 FT (100m) 300 FT (100m) NOTE: FOR LONG-TERM STATIONARY WORK, THE DOUBLE YELLOW CENTERLINE AND/OR LANE LINES SHOULD BE REMOVED BETWEEN THE CROSSWALK LINES. AHEAD SIDEWALK CLOSED CROSS HERE AHEAD SIDEWALK CLOSED USE OTHER SIDE SIDEWALK CLOSED USE OTHER SIDE PEDESTRIAN CROSSWALK PEDESTRIAN DETOUR TRAFFIC MANAGEMENT PLAN DETAILS SHEET 2 OF 2 -19 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - tmp details2022.04.11 1:09:04 PMmillington, dylanby:B C D E F LTRAVEL LANE(SOUTHBOUND)ROADWAY5'-0"CL5'-0"5'-0"TRAVEL LANETRAVEL LANEVARIESEXISTINGPAVEMENTSAWCUT SAWCUT ROADWAYCLGAS MAINC3' MIN.GAS SERVICECONNECTION(SIZE TBD)SUPPORT, PROTECT ANDMAINTAIN ALL EXISTING GASSERVICE CONNECTIONS4x2 CONCRETEDUCT BANKTRAVEL LANE(NORTHBOUND)C11' TRAVEL LANE(DURING CONSTRUCTIONLTRAFFIC CONTROLDEVICE (TYP.)10'-0"SAWCUTSAWCUT 5'-0"TRAVEL LANETRAVEL LANEEXISTINGPAVEMENTSAWCUT SAWCUT ROADWAYCL4X2 CONCRETEDUCT BANK18" MIN.WATER MAINCLGATE VALVE10' MIN. WATER MAINDISPLACEMENTSIDE STREETWATER MAIN(SIZE TBD)VARIESDEPTH VARIES 5' MIN.NOTES1.BI-DIRECTIONAL, ONE-LANE ROAD SHALL OPERATE UNDER POLICE OFFICER CONTROL.2.LENGTH OF ROADWAY UNDER CONSTRUCTION DURINGHALF-ROADWAY CLOSURE SHALL NOT EXCEED 150 LINEARFEET AT ONE TIME.3.ROAD SURFACE MUST BE RESTORED TO TWO-WAYTRAFFIC AT THE END OF EACH WORK.SIDESTREETONE-LANE ROADLANE CLOSEDEXISTINGPAVEMENTROADWAYCLTRAVEL LANE(SOUTBOUND)TRAVEL LANE(NORTHBOUND)8' SHOULDER8' SHOULDER12' TRAVEL LANE(DURING CONSTRUCTIONTEMP.WIDENING(WIDTH VARIES)5'-0"5'-0"SAWCUT SAWCUT 12' TRAVEL LANE(DURING CONSTRUCTIONTRAFFIC CONTROLDEVICE (TYP.)TEMP.WIDENING(WIDTH VARIES)6% MAX.MEET EXIST.EXISTINGPAVEMENT8" GRAVEL BASECOMPACTEDWORK ZONEWORK ZONE12" MIN.UTILITY CROSSINGNOT TO SCALE- SIDE STREET WATER MAIN3UTILITY CROSSINGNOT TO SCALE- SIDE STREET GAS MAIN5HALF-ROADWAY CLOSURENOT TO SCALE- ONE-WAY TRAFFIC8CENTER-ROADWAY CLOSURENOT TO SCALE- TWO-WAY TRAFFIC9UTILITY LINEOR CULVERT3' TO 5' OF IFOBSTRUCTING4x2 CONCRETEDUCT BANK141412"3' MIN.EXISTING GRADEWARNINGTAPEWARNING TAPECROSSING DETAILNOT TO SCALE- IF PASSING7UNDER DRAIN OR CABLE DUCT BANKCSIDE STREETWATER MAIN(SIZE TBD)DEPTH VARIES VARIES5'-0"5'-0"TRAVEL LANETRAVEL LANEEXISTINGPAVEMENTSAWCUT SAWCUT ROADWAYCL18" MIN.WATER MAINLLGATE VALVECWATER MAIN DISPLACEMENTSIDE STREETDEPTH VARIES 5' MIN.CORPORATIONSTOPCLSHUT OFFVALVE4x2 CONCRETEDUCT BANKUTILITY CROSSINGNOT TO SCALE- WATER SERVICE CONNECTION6WARNING TAPEVARIES2'-6" 3'-0"5'-0"ROADWAY (VARIES)5'-0"5'-0"TRAVEL LANETRAVEL LANEVARIESEXISTINGPAVEMENTSAWCUTSAWCUT CLGAS MAINCLVARIES 2'-6"5'-0"12" MIN.TRANSMISSION DUCT BANKNOT TO SCALE- 4x2 ARRAY1UTILITY CROSSINGNOT TO SCALE4BITUMINOUS CONCRETE PAVEMENTTRANSMISSION DUCT BANKNOT TO SCALE- 2x2 ARRAY22'-6"2'-6"3'- 6" MIN. 3'- 6" MIN.GAS PIPE SIZE ANDMATERIAL VARIES,CONTRACTOR TO VERIFYSUPPORT, PROTECT ANDMAINTAIN ALL EXISTING GASSERVICE CONNECTIONS4x2 CONCRETEDUCT BANKWARNING TAPEWARNING TAPE6" OF LOAM AND SEED TO BEPLACED ON TOP OFFLOWABLE FILL TO MATCHEXISTING GRADE.BACKFILL WITH SUITABLE NATIVEMATERIAL AND/OR CLEAN FILL ASSPECIFIED, OR FLOWABLE THERMALBACKFILL (FTB) TO BE USED ASSPECIFIED (SEE NOTE 7 ON SHEET 505)6" OF LOAM AND SEEDTO BE PLACED ON TOPOF FLOWABLE FILL TOMATCH EXISTING GRADE.4x2 DUCT BANK,SEE SHEET 232x2 DUCT BANK,SEE SHEET 23BACKFILL TO MEETREQUIREMENTS OFGAS UTILITYLOW PRESSURE GAS DISTRIBUTION MAINS AND SERVICESBITUMINOUS CONCRETE PAVEMENTWARNING TAPEBACKFILL WITH SUITABLE NATIVEMATERIAL AND/OR CLEAN FILL ASSPECIFIED, OR FLOWABLE THERMALBACKFILL (FTB) TO BE USED ASSPECIFIEDDETAIL SHEET 1-20CLIENT:DOC ID:REVISION DESCRIPTIONREV.DATEAPPRVDCHKDPROJECTTITLE:CONTRACTOR:DRAWNStantec Consulting Services Inc.NEW ENGLAND WIND 1 CONNECTORDUCT BANKSHEET DWG. NO.REV:OFPCW-OCP-STC-DW-0001FSTATUSSCALEFORMAT/SIZETHIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUEDFOR PERMITTING PURPOSES ONLY; AND, IS NOTINTENDED FOR CONSTRUCTION PURPOSES.ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - details2022.04.11 3:29:32 PM millington, dylanby:BCDEF A1A1-3A1A1-1 A1-2 A1-4 A1A1-5 A1A1-6 A1-7 A1A1-8 A1-9 A1A1-10 A1-11 A1A1-12 A1-13 A1A1-14 TYPICAL SPLICE VAULT BYPASS ARRANGEMENT NOT TO SCALE10 CIRCUIT A1 EXAMPLE CONFIGURATION NOT TO SCALE11 NOTES: 1. THIS DRAWING IS PROVIDED ONLY FOR INFORMATIONAL PURPOSES. LENGTHS OF CONDUIT AND BENDS SHOWN ARE BASED ON THE LOCATIONS OF SPLICE VAULTS 1A AND 1B FOR THE VINEYARD WIND CONNECTOR PROJECT, AND SHOULD BE CONSIDERED APPROXIMATE. 2. ALL LENGTHS OF CONDUIT AND FITTINGS ARE ASSUMING BUTT JOINTS. THE APPLICABLE LENGTH LOSS DUE TO THE BELL AND SPIGOT CONNECTIONS MUST BE ADDED TO THE LENGTHS PROVIDED. 3. THE ACTUAL DIMENSION AND LENGTHS OF CONDUIT INSTALLED MAY VARY TO ACCOMMODATE ACTUAL FIELD AND ENVIRONMENTAL CONDITIONS FOR INSTALLATION. 4. THE CONTRACTOR SHALL, BEFORE STARTING EACH PORTION OF THE WORK, , SHALL TAKE FIELD MEASUREMENTS OF ANY EXISTING CONDITIONS RELATED TO THAT PORTION OF THE WORK, AND SHALL OBSERVE ANY FIELD OR ENVIRONMENTAL CONDITIONS AT THE SITE AFFECTING IT. THESE OBLIGATIONS ARE FOR THE PURPOSE OF FACILITATING COORDINATION AND CONSTRUCTION BY THE CONTRACTOR AND ARE NOT FOR THE PURPOSE OF DISCOVERING ERRORS, OMISSIONS, OR INCONSISTENCIES IN THE CONTRACT DOCUMENTS; HOWEVER, THE CONTRACTOR SHALL PROMPTLY REPORT TO THE OWNER/ENGINEER ANY ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED BY OR MADE KNOWN TO THE CONTRACTOR, AS A REQUEST FOR INFORMATION IN SUCH FORM AS THE OWNER/ENGINEER MAY REQUIRE. 5. THE DRAWINGS DO NOT TAKE INTO ACCOUNT THE ABILITY TO DEFLECT LONG RUNS OF STRAIGHT PVC CONDUIT. SHORT-LENGTH BENDS THAT ARE SHOWN MAY BE ABLE TO BE DELETED DURING CONSTRUCTION BY DEFLECTING THE INCOMING OR OUTGOING LENGTH OF PVC CONDUIT. 6. UTILIZE LONG SWEEPING CONDUIT BENDS FOR ALL 8" PVC DUCTS USING A 50' RADIUS, OR AS APPROVED BY THE DESIGN ENGINEER 7. BACKFILL MATERIAL OR FTB TO HAVE A THERMAL RESISTIVITY OF 70°C-cm/W AT A 4% MOISTURE CONTENT OR LOWER 2X2 BYPASS DUCT BANK 2X2 BYPASS DUCT BANK 4X2 DUCT BANK 4X2 DUCT BANK 4X2 DUCT BANK4X2 DUCT BANK 2X2 BYPASS DUCT BANK 2X2 BYPASS DUCT BAN K A1 Sp C1B1 C2 B2 A2 Sp 8'6' 1'-6" FINISHED GRADE SECTION B-B' B2C2 Sp A2 A1 B1 C1 Sp8'6' 1'-6" FINISHED GRADE SECTION A-A' FO1 GCC1 DTS1 FO2 GCC2 DTS2 FO1 GCC1 DTS1 FO2 GCC2 DTS2 PLAN VIEW PROFILE VIEW A A' B B' C2 B2 A2 Sp 8'6' 1'-6" FINISHED GRADE VAULT 9B ROLLOVER FO2 GCC2 DTS2 FO1 GCC1 DTS1 B1 Sp A1 C1 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - details2022.04.11 3:29:39 PMmillington, dylanby:B C D E F DETAIL SHEET 2 -21 NOTES 1. LOCATION OF CONSTRUCTION JOINTS (C.J.) ARE PROPOSED. CONTRACTOR SHALL DETERMINE THE FINAL LOCATION AND DESIGN OF CONSTRUCTION JOINTS. 10" 10" 10"6'-0"8'-0"10"6'-0"8'-0"6'-0" I.D.10" (TYP.) 3'-8" (TYP) 10"2'-0"1'-8"MIN.26'-0" I.D. A A B B D D SECTION D-DSECTION C-C SECTION A-A PLAN C C 8'-0" I.D.E E 10" (TYP) 10" (MIN.)2'-0"1'-6"1'-0"1'-6" 10" SECTION B-B 26'-0" I.D. (20 PLACES)2'-0"(TYP)2-0" (TYP) SECTION E-E 8" DUCT TERMINATOR DETAIL NOT TO SCALE13 2" DUCT TERMINATOR DETAIL NOT TO SCALE14 INSIDE OUTSIDE INSIDE OUTSIDE B B D D C C 10"2'-0"1'-6"1'-0"10"8'-0"10" 10"A A B D D C C B 1'-6" SLOPE SLOPE 1'-6"1'-6"1'-0"1'-0"SLOPE(1%)SLOPE (1%)SLOPE(1%)SLOPE (1%) MIN. (TYP.) 6'-0"4'-0"6" 6" CABLE SUPPORT SYSTEM (BY OTHERS) (3) 8" SCH 40 PVC CONDUIT ENTRY FOR HV CABLE' (4) 8" CABLE CONDUITS 38"Ø MANHOLE FRAME & COVER (TYP.)FINISHED GRADE 38"Ø MANHOLE (2 TYP.) (1) 8" SCH 40 PVC CONDUIT ENTRY FOR SPARE CABLE. SUMP (TYP) (1) 2" SCH 40 PVC CONDUIT ENTRY FOR GROUNDING CONDUCTOR. PULLING IRON (TYP 4 PLACES) WALL MOUNTED LINK BOX (BY OTHERS) HV CABLE (TYP) DUCT BANK (TYP) 1-0"x1'0"x6" DEEP SUMP IN FLOOR (2 PLACES) WITH COVER GRATING CAST-IN-PLACE 8" SCH 40 PVC COUPLING ADAPTER (TRIM FLUSH WITH FACE OF WALL) CAST -IN-PLACE KOS 200/200 ROXTEC KNOCK-OUT SLEEVE WITH SEAL END TOWARDS INTERIOR. DUCT TERMINATOR SHALL BE FLUSH WITH INTERIOR AND EXTERIOR WALL SURFACE CAST-IN-PLACE 2" SCH 40 PVC EXTENDER WITH BELLED END TOWARDS OUTSIDE. DUCT TERMINATOR SHALL BE FLUSH WITH INTERIOR AND EXTERIOR WALL SURFACE (1) 2" SCH 40 PVC CONDUIT ENTRY FOR DTS. CAST-IN-PLACE T2000 MEADOW BURKE 2" DUCT TERMINATOR WITH FLARED SEAL RING TOWARDS INTERIOR. DUCT TERMINATOR SHALL BE FLUSH WITH INTERIOR AND EXTERIOR WALL SURFACE (1) 2" SCH 40 CONDUIT ENTRY COMM. FO. (1) 2" SCH 40 CONDUIT ENTRY COMM. FO. C.J. WITH BELL-TYPE PVC WATERSTOP (TYP) C.J. WITH BELL-TYPE PVC WATERSTOP (TYP) PROPOSED INTERLOCKING RISER JOINT LOCATION 1" CONDUIT SLEEVE (PROVISION FOR GROUND ROD) PRECAST SPLICE VAULTS NOT TO SCALE12 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - details2022.04.11 3:29:49 PMmillington, dylanby:B C D E F DETAIL SHEET 3 -22 TYPICAL VAULT INSTALLATION DETAIL NOT TO SCALE16 1. REFER TO SPECIFICATION FOR PRECAST VAULT (TBC) 2. ANTI-FLOTATION MEASUES SHALL BE INCORPORATED AS REQUIRED 3. OVERHEAD CLEARANCES ALONG VAULT AND DUCT BANK 4. WARNING TAPE TO BE PLACED HALF WAY BETWEEN FINISHED GRADE AND TOP OF DUCT BANK NOTES 6'-0"8'-0"PAVEMENT REPAIR AS SPECIFIED 38"Ø MANHOLE FRAME & COVER (TYP.) CONCRETE GRADE RINGS (8" ADJUSTMENT MAX.) FINISHED GRADE 24" 3/4" CRUSHED STONE M2.01.4 UNDISTURBED COMPACTED SUBGRADE OR COMPACTED SUITABLE BACKFIL MATERIAL 12" 1-1/2" CRUSHED STONE M2.01.2 6" OF LOAM AND SEED GEOTEXTILE FILTER FABRIC (REFER TO NOTE 5) TWO LANDFALL DIRECT BURIAL JOINT BAY DETAILS NOT TO SCALE15 NOTES 1. 50' STRAIGHT PORTION ON EACH SIDE OF THE 6.5' JOINT BAY TO ALLOW FOR FUTURE REPAIR IF REQUIRED. LAND CABLE DUCTS 14'-0"62'-10" SUBSEA CABLE ANCHOR TRANSITION JOINT (TYP.) 2'-6" 5'-0" 4" 1'-0" TYP. 1'-0" TYP. A1 Sp C2 B2 B1 C1 Sp A2 THERMAL CONCRETE FO 1, COMM. 2" PVC POWER CABLE CONDUIT 8"Ø SCH 40 PVC (8 TYP.) GCC 1, 2" PVC GCC 2, 2" PVC FO2, COMM. 2" PVC CKT 1 DTS MONITORING FIBER OPTIC 2" PVC CKT 2 DTS MONITORING FIBER OPTIC 2" PVC 2'-6" 1'-0" TYP. 2'-6"THERMAL CONCRETE FIBER OPTIC/COMMUNICATIONS CONDUIT 2" PVC (3 TYP.) POWER CABLE CONDUIT 8"Ø SCH 40 PVC GCC CONDUCTOR, 2" PVC DTS MONITORING FIBER OPTIC 2" PVC 5'-0" 1'-3" FIBER OPTIC/COMMUNICATIONS CONDUIT 2" PVC (3 TYP.) GCC CONDUCTOR, 2" PVC DTS MONITORING FIBER OPTIC 2" PVC POWER CABLE CONDUIT 8"Ø SCH 40 PVC 1'-0" TYPTRANSMISSION DUCT BANK NOT TO SCALE - 4x2, 2x2 AND 1x4 ARRAYS17 DETAIL SHEET 4 -23 CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - details2022.04.11 3:29:59 PMmillington, dylanby:B C D E F 48"36" 24" PLAN-CONCRETE BASE 2'-0" 12" 12"2'-0"12"6'-0"FABRIC7'-0"12'-0" C BASEL BALES SHALL BE PLACED IN A ROW WITH ENDS TIGHTLY ABUTTING THE ADJACENT BALES. EACH BALE SHALL BE EMBEDDED IN THE SOIL A MINIMUM OF 3". BALES SHALL BE SECURELY ANCHORED IN PLACE BY STAKES OR RE-BARS DRIVEN THROUGH THE BALES. THE FIRST STAKE IN EACH BALE SHALL BE ANGLED TOWARD PREVIOUSLY PLACED BALE TO FORCE THE BALES TOGETHER. INSPECTION SHALL BE FREQUENT AND REPAIR OR REPLACEMENT SHALL BE MADE PROMPTLY AS DIRECTED BY THE ENGINEER. BALES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFULNESS SO AS NOT TO BLOCK OR IMPEDE STORM FLOW OR DRAINAGE. CATCH BASIN INSERT NOT TO SCALE FOR SEDIMENT CONTROL18 TEMPORARY CONSTRUCTION FENCE NOT TO SCALE21 DEWATERING DISCHARGE DIRECTION OF FLOW DEWATERING DISCHARGE 10' (APPROX.)8' (APPROX.)SEDIMENTATION CONTROL BASIN NOTES: 1. SEDIMENTATION CONTROL BASINS SHALL BE SIZED AND INSTALLED TO HANDLE ALL OF THE DEWATERING NECESSARY DURING CONSTRUCTION. NO OVERFLOW OF THE BASIN SHALL OCCUR. CONTRACTOR TO INSTALL AND MAINTAIN MULTIPLE SEDIMENTATION BASINS AS NECESSARY TO HANDLE ALL TRENCH DEWATERING DISCHARGE AND MEET THE REQUIREMENT OF ALL PERMITS. 2. SEDIMENTATION BASINS TO BE LOCATED ADJACENT TO THE ROADWAY GUTTER LINE, WITHIN THE TOWN RIGHT-OF-WAY. 3. CRUSHED STONE, FILTER FABRIC, JUTE NETTING AND FLOC LOG CHECK DAMS SHALL BE PLACED IN THE ROADWAY GUTTER LINE BETWEEN THE SEDIMENTATION CONTROL BASIN AND RECEIVING DRAINAGE STRUCTURES, AS DETAILED ON THIS SHEET. FLOC LOGS SHALL BE SPECIFICALLY DESIGNED FOR NATIVE SEDIMENT TYPE AND SIZE.20' (APPROX.)EXISTING CURB AND/OR EDGE OF PAVEMENT SEDIMENTATION CONTROL CHECK DAM NOTES: 1. SEDIMENTATION CONTROL CHECK DAMS SHALL BE PLACED IN SERIES BETWEEN THE DEWATERING DISCHARGE AND RECEIVING DRAINAGE STRUCTURE(S). 2. CHECK DAM HEIGHT AND WIDTH VARIES BASED ON SLOPE OF THE ROADWAY, DISCHARGE FLOW RATE AND CLEARANCE FROM VEHICULAR TRAFFIC. 3. CHECK DAMS MUST NOT IMPEDE VEHICULAR TRAFFIC IN THE IMPACTED LANE OF TRAVEL. HEIGHT AND WIDTH VARIES SEDIMENTATION CONTROL BASIN PLAN NOT TO SCALE23 CHECK DAMS SILTATION CONTROL NOT TO SCALE24 C BASEL SECTION WORK AREAPROTECTED AREA PLAN SECTION PROTECTED AREAWORK AREA 36" MIN EXPOSED HEIGHT SHEET FLOW EMBED FILTER FABRIC 6" INTO GROUND NOT TO SCALE SILT FENCE DETAIL WITH WATTLES22 1'-0" TO TOE OF SLOPE6" MIN. EROSION BARRIER TO BE PLACED ALONG LIMITS OF CONSTRUCTION OR WETLANDS EDGE AS INDICATED ON THE PLAN EROSION CONTROL BARRIER DETAIL NOT TO SCALE WITH HAYBALES20 DEWATERI N G DISCHAR G E EXCAVATION BOTTOM OF TEMPORARY SEDIMENT TRAP NOT TO SCALE19 SECTION RETRIEVAL STRAP CATCH BASIN GRATE OVERFLOW GEOTEXTILE FABRIC GEOTEXTILE SKIRT 1 5/8" 40 WEIGHT FRAME 2.067" I.D. SLEEVE GRADE LINE FABRIC FASTENERS @ 15" O.C. TOP & BOTTOM BAND ADJACENT SECTION @ 18" O.C. 1/4" X 3/4" STRETCHER BARS W/ 11 GAGE FASTENERS @ 12" O.C. 1.900" O.D. POSTS 2'X2'X6' CONC. BASE (TYP.) BALED STRAW 3/4" CRUSHED STONE LAYER BELOW FILTER BAG 3/4" CRUSHED STONE WRAPPED IN FILTER FABRIC ANCHORED FLOC LOGS SITTING ON JUTE NETTING FILTER FABRIC BELOW CRUSHED STONE LAYER, OVERLAP ABOVE STRAW BALES FILTER BAG 3/4" CRUSHED STONE LAYER BELOW FILTER BAG BALED STRAW FILTER BAG WOODEN POST STAKES USE 2"X4" SOFTWOOD OR 1-1/2"x1-1/2" OAK SPACED MAXIMUM OF 8' O.C. TOP OF GROUND UNDISTURBED GOUND STAKE WATTLES CONTINUOUSLY ON CONTOURS WITH 24" STAKES AT MAX 5' O.C. UV RESISTANT HIGH-TENACITY POLYPROPYLENE WOVEN FABRIC HEAVY-DUTY POLYPROPYLENE CABLE SEWN IN SILT FENCE FABRIC (TOP & BOTTOM), CABLE TO BE ATTACHED TO SILT FENCE POST. SILT FENCE FABRIC BALED HAY OR STRAW STAKED IN PLACE OAK POST2"x 2"x 4'-6'(MAX.) METAL CONNECTOR CABLE, 1/8" 0 (MIN.) INDUSTRIAL SUPPORT NETTING 2"x2"x3' STAKES 2 PER HAYBALE HAYBALES TO BUTT TOGETHER SILTATION FENCE (2) 2"x 2"x 4' STAKES EACH BALE RIP RAP PAD 1' MAX. SIZE STONE DOUBLE ROW BALEDSTRAW (TYP.) DOUBLE ROW BALED STRAW (TYP.) CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - details2022.04.11 3:30:09 PMmillington, dylanby:B C D E F DETAIL SHEET 5 -24 1.PLATES TO BE USED ONLY WHILE CDF IS CURING. 2. MAXIMUM DEFLECTION ALLOWABLE OF PLATES IS 3 4". 3. PLATE PINS SHALL BE MINIMUM 1" DIAMETER SPIKE AND 8" IN LENGTH. PLAN VIEW TRAFFIC FLOW SECTION VIEW NOTES: TRENCH WIDTH 12" CUT BACK TRENCH WIDTH EXIST PVMNT TO REMAIN DISTANCE VARIES 12" EXIST PVMNT TO REMAIN DISTANCE VARIES 12" CUT BACK TRENCH WIDTH NOTE: 1. TACK COAT ALL VERTICAL SURFACES OF EXISTING PAVEMENT BEFORE PLACEMENT OF PERMANENT TRENCH PAVEMENT 2. MATERIAL WHICH MEETS THE SPECIFICATION FOR GRAVEL BORROW TYPE C (M1.03.0 TYPE C), PLACED AND COMPACTED IN LAYERS NO GREATER THAN 6", MAY BE USED IN PLACE OF THE CDF WITH APPROVAL FROM THE DISTRICT HIGHWAY DIRECTOR. 3. THE EXPOSED EDGES OF ALL LONGITUDINAL AND TRANSVERSE SAW CUT JOINTS SHALL BE TREATED WITH HOT POURED RUBBERIZED ASPHALT JOINT SEALANT MEETING MASSDOT SPECIFICATIONS. NOTE: 1. TACK COAT ALL VERTICAL SURFACES OF EXISTING PAVEMENT BEFORE PLACEMENT OF TEMPORARY TRENCH PAVEMENT. 6" 6"6" ROADWAY SURFACE S=1.6% MAX. S=5-15% VARIES 4' MIN1' MIN. TO 3' MAX. 4' MIN (VARIES)1' MIN. TO 3' MAX. PLAN SECTION LOAM SEED& GRAVEL BASE COURSE 2-1/2" BIT. BINDER COURSE 1-1/2" BIT. SURFACE COURSE DEPTH VARIES 12" LEVEL 12"6"33°1'-0" KEYWAY TRENCH PLATE INSTALLATION WITH CDF BACKFILL NOT TO SCALE12 TEMPORARY TRENCH PAVEMENT (MASSDOT ROADWAY) NOT TO SCALE13 PERMANENT TRENCH PAVEMENT (MASSDOT ROADWAY) NOT TO SCALE17 BITUMINOUS CONCRETE SIDEWALK DETAIL NOT TO SCALE14 KEYWAY DETAIL FOR CONNECTION FOR EXISTING PAVEMENT NOT TO SCALE15 BITUMINOUS CONCRETE BERM DETAIL NOT TO SCALE16 GRANITE CURB RESETTING DETAIL NOT TO SCALE18 BITUMINOUS CONCRETE DRIVEWAY NOT TO SCALE19 CONTROLLED DENSITY FILL MILL 2" OF EXIST PAVEMENT (TYP) TO ALLOW FOR INSTALLATION OF PLATES FLUSH WITH EXIST PAVEMENT 2" THICK STEEL PLATES, PINNED AND WELDED COMPACTED GRAVEL BORROW NEW PAVEMENT PER TEMP TRENCH PAVEMENT DETAIL, THIS SHEET. 3 TACK WELDS PER PLATE TYP BACKFILL TRENCH IN THIS AREA WITH CDF MATERIAL PIN PLATES, TYP. MIN 12" OVERLAP OF PLATE ON ALL TRENCH EDGES EXIST EDGE OF TRENCH 1 3 4" SUPERPAVE SURFACE COURSE 12.5 (SSC-12.5) 2 14" SUPERPAVE INTERMEDIATE COURSE 19.0 (SIC-19.0) 3 12" SUPERPAVE BASE COURSE 37.5 (SBC-37.5) SIDEWALK GRANITE CURB EXIST AND FINISH GRADE MIN. 12" GRAVEL BASE (MAX. 3" AGGREGATE) FOR PAVEMENT OR CDF AS REQUIRED PIN PLATES, TYP EXIST GRADE SIDEWALK GRANITE CURB EXIST AND FINISH GRADE 6" GRAVEL BORROW OR PROCESSED STONE (SUB-BASE) 3 12" BINDER COURSE TACK COAT (SEE NOTE 1) TACK COAT (SEE NOTE 1) MIN. 12" GRAVEL (BANK RUN) BASE (MAX. 3" AGGREGATE) FOR PAVEMENT OR CDF AS REQUIRED 6" LOAM & SEED 1 3 4" BINDER COURSE 1 14" TOP COURSE 2" SELECT BORROW SUBBASE 6" GRAVEL BORROW (TYP.) (8" AT DRIVEWAYS) RESET EXIST. GRANITE CURB REVEAL TO MATCH EXISTING BIT. CONC. TOP COURSE 6" LOAM & SEED GRAVEL BORROW GRAVEL SUBBASE SEE PAVEMENT DETAIL RADIUS AND DIMENSION TO MATCH EXISTING 4" TOP COURSE 8" COMPACTED GRAVEL COMPACT SMOOTH MAINTAIN 1" LIP SLOPE VARIES SPILL BERM (UNROLLED BINDER) TO CONTROL RUNOFF PRIOR TO BERM PLACEMENT AND TO ANCHOR BERM 1" LIP INTERMEDIATE AND/OR BASE TOP COURSESAWCUT AND REMOVE EXIST. PAVEMENT. COAT EXPOSED EDGES OF EXISTING PVMT. WITH BIT. EMULSION PRIOR TO PLACING ABUTTING PAVEMENT CLIENT: DOC ID: REVISION DESCRIPTIONREV.DATE APPRVDCHKD PROJECT TITLE: CONTRACTOR: DRAWN Stantec Consulting Services Inc. NEW ENGLAND WIND 1 CONNECTOR DUCT BANK SHEET DWG. NO.REV: OF PCW-OCP-STC-DW-0001 F STATUS SCALE FORMAT/SIZE THIS PLAN SET IS PRELIMINARY AND HAS BEEN ISSUED FOR PERMITTING PURPOSES ONLY; AND, IS NOT INTENDED FOR CONSTRUCTION PURPOSES. ORIGINAL SHEET - ANSI Dc:\pwworkdir\d0585436\vineyard wind - 501 south - details2022.04.11 3:30:19 PMmillington, dylanby:B C D E F DETAIL SHEET 6 -25