Loading...
HomeMy WebLinkAbout737.1 Hyannis Dockside Condos Planning Board Set 1-13-23297 North Street, Suite 121Hyannis, MA 02601T-1Mr. Stuart BornsteinHolly Management and Supply CorporationDRAWING LISTProject Summary505 Middlesex Turnpike #14Billerica, MA 01820978-362-1804TLH ConsultingSTRUCTURALOWNER/CLIENTARCHITECTCIVIL939 Route 6A, Suite CYarmouth Port, MA 02675508-362-4541Down Cape Engineering, Inc.Hyannis Dockside Condos110 School Street & 115 School Street Street, Hyannis, MA 0260106/29/22Progress SetHyannis Dockside CondosArea of WorkLocus PlanBuilding Aerial ViewREVISED 01/13/23These drawings depict the redevelopment of two parcels within the historic waterfront district of Hyannis for 29 new condominium units, based on provided building footprints and site strategy. The scope of work for this project will include:1. Modifications to the building footprint, including a. the removal of the western building closest to South street and replacement with an exterior green spaceb. the addition of one additional stories to the five southern buildings (W3, W4, E2, E3, & E4)2. Modifications to the building height3. Decrease the number of units from 33 to 294. Redefinition of the architectural style of the projectArea of WorkGeneral Project InformationT-1 Title SheetArchitecturalA011 Building Program First FloorA021 Building Program Upper LevelsA101 Garage Floor PlanA111 First Floor PlanA121 Second Floor PlanA131 Third Floor PlanA141 Fourth Floor PlanA151 Mezzanine Floor PlanA161 Mezzanine Floor PlanA171 Roof PlanA201 Building ElevationsA202 Building ElevationsA203 Building ElevationsA204 Building ElevationsA210 Building Eave HeightsNo longer includedPLANNING BOARD SET DNDNUPDNUPUPUPDNUnit 107Unit 105Unit 103Unit 101Unit 108Unit 102Unit 104Unit 106School StreetProperty lineProperty lineRamp DNRamp DNSouth StreetInOutOutInStair W1Stair W2Elev W2Stair W3Elev W1Elev W3Stair W4Stair E1Stair E3Elev E4 Elev E1Elev E2 Elev E5Stair E4Stair E2Stair E5Stair E6Elev E3CorridorW31CorridorE3CorridorE2CorridorE4CorridorE5CorridorE1CorridorW2Ramp DNCheck by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:09 PM3/32" = 1'-0"A011BuildingProgram FirstFloor LevelSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1Building ProgramN016'24'32'Graphic Scale: 3/32 inch = 1 foot8'No. Date Description1 01/10/23 Planning BoardRevisions1 REF.REF.REF.REF.REF.REF.REF.REF.Stair W1Stair W2Elev W2Stair W3Elev W1Elev W3Stair W4Stair E1Stair E3Elev E4 Elev E1Elev E2Elev E5Stair E4Stair E2Stair E5Stair E6Elev E3CorridorW32Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:16 PM3/32" = 1'-0"A021BuildingProgram UpperLevelsSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1Building ProgramN016'24'32'Graphic Scale: 3/32 inch = 1 foot8'No. Date Description1 01/10/23 Planning BoardRevisions1 UPUPDNUPUPUP1A3012A302W.2W.3W.4W.5W.1W.6W.DW.CW.BW.AW.EW.FW.GW.HW.IW.JW.KW.L19' - 4"19' - 4"19' - 4"19' - 4"19' - 4"16' - 6 3/4"18' - 6"45678 91112 HA VAN13141516192025 HA VAN2721222324WS1004WS2005WS3007WS5010WS4006WS6011WS8014WS7015WS9016WS10017W.J.2E.2E.1E.3E.4E.5E.8E.CE.DE.EE.FE.GE.HE.IE.JE.KElev W100014568111315192023252725' - 0"33E.I.232DN 6%DN 6%DN 12%DN 6%DN 6%DN 12%School StreetProperty lineProperty line1816115 School Street27 parking spaces110 School Street33 parking spacesTotal 60 garage parking spaces10 on site parking spaces70 parking spaces totalE.BE.A2318 HA VAN117Trash W036Trash E037E.716' - 4 1/4"19' - 4"6' - 11 3/4"10' - 4 3/4"20' - 0"19' - 4"22' - 6"19' - 4"19' - 4"19' - 4"14' - 1 3/4"WestGarage001EastGarage020Stair E300111A3022A301Elev E10004Elev W20002Elev E200053107UPElev W30003Elev E40007Elev E50008219 HA VAN2217SprinklerRoomSprinklerRoom25' - 0"E.6293031Elev E300062110121426StorageStorageStorageStorageStorageStorage242628ES1 ES2ES3ES4ES5ES6ES7 ES8ES9ES10ES11FACPFACPPool area (above)19' - 4"19' - 4"6' - 11 3/4"10' - 4"22' - 0 3/4"211' - 0 1/4"88' - 2 3/4"122' - 9 1/2"211' - 0 1/4"78' - 6"132' - 6 1/4"78' - 10 1/4"78' - 9 3/4"39' - 5 3/4"3456891019' - 0"9' - 0"12' - 0"25' - 2 1/2"23' - 6 3/4"18' - 10 1/2"20' - 3 1/4"20' - 0"26' - 11"24' - 3 3/4"25' - 2 1/2"5' - 2 1/4"20' - 0"712Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:19 PM3/32" = 1'-0"A101Garage FloorPlanSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1Garage Floor PlanN016'24'32'Graphic Scale: 3/32 inch = 1 foot8'No. Date Description1 01/10/23 Planning BoardRevisions1 DNDNDNDNUPUPUPUPDNUPDNDNDNDNUPUPUPREF.REF.REF.REF.REF.REF.REF.UPREF.DNDNDN1A3012A302W.2W.3W.4W.5W.1W.6W.DW.CW.BW.AW.EW.FW.GW.HW.IW.JW.KW.LW.J.2E.2E.1E.3E.4E.5E.8E.CE.DE.EE.FE.GE.HE.IE.JE.KE.I.2Unit 107Unit 105Unit 103Unit 101Unit 108Unit 102Unit 104Unit 106A4011A4021A4031A4041School StreetProperty lineProperty line115 School Street110 School StreetE.BE.AE.7Ramp DNRamp DNInOutOutInStair W4Stair E2Stair W1Stair W3Stair E4Stair E5Stair E1UPStair W2Elev W11A3022A301Elev W2Elev E1Elev E2Stair E3Stair E6Elev W3Elev E4Elev E5E.6Elev E3DeckDeckDeckDeckDeckCorridorW31CorridorW2DeckDeckDeckDeckDeckDeckDeckCorridorE1PoolHouseCorridorE4CorridorE5CorridorE2CorridorE3DeckPoolTrash ETrash WMail AreaMail AreaStair to be precast, serving podium onlyStair to be precast, serving garage onlyStair to be precast, serving podium onlyStair to be precast, serving garage onlyStair to be precast, serving podium onlyStair to be precast, serving garage onlyStair to be precast, serving garage onlyStair to be precast, serving podium onlyStair to be precast, serving garage onlyStair to be precast, serving 3 storiesStair to be precast, serving 3 storiesStair to be precast, serving 4 storiesStair to be precast, serving 4 storiesStair to be precast, serving 3 storiesStair to be precast, serving 4 storiesStair to be precast, serving 4 storiesStair to be precast, serving 5 stories (garage & floors 1-4)Ramp DNGenerator locationGenerator locationCheck by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:25 PM3/32" = 1'-0"A111First Floor PlanSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/22N3/32" = 1'-0"1First Floor Plan016'24'32'Graphic Scale: 3/32 inch = 1 foot8'No. Date Description1 01/10/23 Planning BoardRevisionsGreen wall1 DNUPDNDNUPDNUPDNDNDNUPUPUPDNUPUPREF.UPDNREF.REF.REF.REF.REF.REF.REF.1A3012A302W.2W.3W.4W.5W.1W.6W.DW.CW.BW.AW.EW.FW.GW.HW.IW.JW.KW.LW.J.2E.2E.1E.3E.4E.5E.8E.CE.DE.EE.FE.GE.HE.IE.JE.KE.I.2Unit 207Unit 205Unit 203Unit 201Unit 208Unit 202Unit 204Unit 206115 School Street110 School StreetE.BE.AE.7UPDNStair W1Stair W2Stair W3Elev W1Stair W4Stair E2Stair E4Stair E3Stair E5Stair E11A3022A301Elev W2Stair E6Elev E1Elev E2Elev E4Elev E5Elev W3E.6Elev E3DeckDeckDeckDeckDeckDeckDeckCorridorW32DeckA4281DeckDeckDeckDeckDeckDeck----Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:29 PM3/32" = 1'-0"A121Second FloorPlanSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1Second Floor Plan016'24'32'Graphic Scale: 3/32 inch = 1 foot8'NNo. Date Description1 01/10/23 Planning BoardRevisions1 DNUPDNDNUPDNUPDNUPDNUPDNDNREF.UPDNREF.REF.REF.REF.REF.REF.REF.1A3012A302W.2W.3W.4W.5W.1W.6W.DW.CW.BW.AW.EW.FW.GW.HW.IW.JW.KW.LW.J.2E.2E.1E.3E.4E.5E.8E.CE.DE.EE.FE.GE.HE.IE.JE.KE.I.2Unit 307Unit 305Unit 303Unit 301Unit 308Unit 302Unit 304Unit 306115 School Street110 School StreetE.BE.AE.7Stair W1Stair W2Stair W3Elev W1Stair W4Stair E1Stair E2Stair E3Stair E4Stair E51A3022A301Stair E6UPDNElev W2Elev E1Elev E2Elev E4Elev E5Elev W3E.6Elev E3DeckDeckDeckDeckDeckDeckDeckCorridorW33DeckDeckA4351A4361A4391Deck DeckDeckDeck----Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:34 PM3/32" = 1'-0"A131Third Floor PlanSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1Third Floor Plan016'24'32'Graphic Scale: 3/32 inch = 1 foot8'NNo. Date Description1 01/10/23 Planning BoardRevisions1 DNDNDNDNDNREF.DNREF.REF.REF.REF.UPUPUPUPUP1A3012A302W.2W.3W.4W.5W.1W.6W.DW.CW.BW.AW.EW.FW.GW.HW.IW.JW.KW.LW.J.2E.2E.1E.3E.4E.5E.8E.CE.DE.EE.FE.GE.HE.IE.JE.KE.I.2115 School Street110 School StreetE.BE.AE.7Stair W3Elev W1Stair W4Stair E2Stair E1Stair E3Stair E41A3022A301Unit 403Unit 401Unit 402Unit 404Unit 406Elev E1Elev E2Elev E5Elev E4Elev W3E.6DeckDeckDeckDeckDeckDeckDeckDeckDeckMezzanine aboveMezzanine aboveMezzanine aboveMezzanine aboveMezzanine aboveSloped ceiling----Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:36 PM3/32" = 1'-0"A141Fourth FloorPlanSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1Fourth Floor Plan016'24'32'Graphic Scale: 3/32 inch = 1 foot8'NNo. Date Description1 01/10/23 Planning BoardRevisions1 DNDNDNDNDN1A3012A302W.2W.3W.4W.5W.1W.6W.DW.CW.BW.AW.EW.FW.GW.HW.IW.JW.KW.LW.J.2E.2E.1E.3E.4E.5E.8E.CE.DE.EE.FE.GE.HE.IE.JE.KE.I.2115 School Street110 School StreetE.BE.AE.7Stair E31A3022A301E.6A4571A4581A4601A4611A4621Open to below(8'-4" Ceil. Ht.)Sloped ceiling5'-5" high knee wallHalf-wallFull height wallMezzanineOpen to below(8'-4" Ceil. Ht.)Sloped ceilingHalf-wall5'-0" knee wallMezzanineOpen to below(8'-4" Ceil. Ht.)Sloped ceiling7'-3 1/2" knee wallHalf-wallMezzanineOpen to below5'-0" knee wallHalf-wallSloped ceiling(8'-4" Ceil. Ht.)MezzanineOpen to below(8'-4" Ceil. Ht.)Full height wallHalf-wallMezzanine----Unit 403Unit 401Unit 402Unit 404Unit 406Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:37 PM3/32" = 1'-0"A151MezzanineFloor PlanSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1Mezzanine Floor Plan016'24'32'Graphic Scale: 3/32 inch = 1 foot8'NNo. Date Description2 01/13/23 Planning BoardRevisions1 01/10/23 Planning BoardRevisions122222 REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.REF.DNREF.1A3012A302W.2W.3W.4W.5W.1W.6W.DW.CW.BW.AW.EW.FW.GW.HW.IW.JW.KW.LW.J.2E.2E.1E.3E.4E.5E.8E.CE.DE.EE.FE.GE.HE.IE.JE.KE.I.2E.BE.A115 School Street110 School StreetE.7Property lineProperty line1A3022A301E.6KeyDownspoutGutter Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 4 1/2:12Pitch 4 1/2:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 3 1/2:12Pitch 3 1/2:12Pitch 1 1/2:12Pitch 7:12Pitch 7:12 (typ.)Pitch 2 1/4:12Pitch 7:12Pitch 2 1/4:12Pitch 1 1/2:12Pitch 1 1/2:12Pitch 7:12Pitch 7:12Pitch 7:12Pitch 10:12Pitch 21:12Pitch 21:12Pitch 21:12Tower (typ.)Upper roof pitch 7:12Middle roof pitch 22:12Lower roof pitch 9:12# gauge copperEPDMArchitectural shinglesPitch 1 1/4:12Pitch 1 1/4:12Pitch 1/4:12Pitch 1/4:12Pitch 1/4:12RidgeRidgeRidgeValleyValleyRidgeRidgeRidgeRidgeValleyValleyValleyValleyRidgeRidgeValleyValleyValleyValleyRidgeRidgeValleyValleyValleyValleyRidgeRidgeRidgeRidgeValleyValleyValleyValleyRidgeRidgeRidgeValleyValleyValleyValleyRidgeRidgeValleyValleyRidgeRidgeRidgeRidgeRidgeRidgeRidgeValleyValleyRidgeRidgeRidgeRidgeValleyValleyValleyValleyRidgeRidgePitch 7:12Pitch 7:12RidgeRidgeRidgeValleyValleyPitch 7:12Pitch 7:12Pitch 21:12Pitch 7:12Pitch 1 1/2:12Pitch 1/4:12Pitch 1/4:12Gutter at all roof eaves (typ.)Gutter at all roof eaves (typ.)Gutter at all roof eaves (typ.)Gutter at all roof eaves (typ.)Gutter at all roof eaves (typ.)----Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:41 PM3/32" = 1'-0"A171Roof PlanSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1Roof Plan016'24'32'Graphic Scale: 3/32 inch = 1 foot8'NNo. Date Description1 01/10/23 Planning BoardRevisions1 First Floor SubfloorSecond FloorSubfloorGarage Floor PlanThird Floor SubfloorFourth FloorSubfloorMezzanine FloorSubfloor2A302W.DW.CW.BW.AW.EW.FW.GW.HW.IW.JW.KW.LW.J.22A301C2C2C2C2A2A2A2A2DDDDB2B2B2BBBBBA4A4A4B2GA3A3A3IW167W267W367W467W179753752751W144017W124W114W214W314W301CW Average ofHighest RoofElevation =W Average Grade Plane27' -7 3/4"Building Height58' - 7"First Floor SubfloorSecond FloorSubfloorGarage Floor PlanThird Floor SubfloorFourth FloorSubfloorMezzanine FloorSubfloor2A302E.CE.DE.EE.FE.GE.HE.IE.JE.KE.I.2E.BE.A2A301Fourth Floor PlateHeight E1E104DAA2ABBBBBBBA2A2A2A2C2C2A3A3A3A3E Average ofHighest RoofE204AA2A930AA2AElevation =E Average Grade Plane27' -7 1/4"Building Height60' - 1"----Note:These buildings have been designed to be classified as mid-rise buildings. MA amendments to the IBC define mid-rise as a building that does not exceed 70 ft above the grade plane. A high rise building is a building more than 70 feet in height above grade plane. Building height per IBC is defined as the vertical distance from the grade plane to the average height of the highest roof surface. The grade plane elevation of the East Parcel Building is at Elevation = 27’-7 1/4". The height from grade plane to the average of the highest roof surface is 60'-1”. The grade plane elevation of the West Parcel Building is at Elevation =27’-7 3/4". The height from grade plane to the average of the highest roof surface is 58’-7”. Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:48 PM3/32" = 1'-0"A201BuildingElevationsSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1School Street: East Elevation of West Building3/32" = 1'-0"2School Street: West Elevation of East BuildingNo. Date Description1 01/10/23 Planning BoardRevisions1 First Floor SubfloorSecond FloorSubfloorGarage Floor PlanThird Floor SubfloorFourth FloorSubfloorMezzanine FloorSubfloor1A301W.2W.3W.4W.5W.1W.6E.2E.1E.3E.4E.5E.8E.71A302E.6Fourth Floor PlateHeight E1AA2AAA2AAA2AAA2AIDDBBBBB2BB2BB2DBFFA3IE480E380E280E101E234E334E434623W101W143W Average ofHighest RoofE Average ofHighest RoofD2DBD2DBA2912Elevation =E Average Grade Plane27' -7 1/4"Elevation =W Average Grade Plane27' -7 3/4"Building Height60' - 1"Building Height58' - 7"CCCIIFirst Floor SubfloorSecond FloorSubfloorGarage Floor PlanThird Floor SubfloorFourth FloorSubfloorMezzanine FloorSubfloor1A301W.2W.3W.4W.5W.1W.6E.2E.1E.3E.4E.5E.8E.71A302E.6A3A3A3A3DDW460W360W260W160W164W166W266W366W466BBBBA3A3A3A3E145E245E345E445DDDE148E463E363E263E163E166E266E366E466DDDE169E492E392E292E192EEEEEEEEEEEEW Average ofHighest RoofE Average ofHighest RoofElevation =E Average Grade Plane27' -7 1/4"Elevation =W Average Grade Plane27' -7 3/4"Building Height58' - 7"Building Height60' - 1"IHEEEIGHNote:These buildings have been designed to be classified as mid-rise buildings. MA amendments to the IBC define mid-rise as a building that does not exceed 70 ft above the grade plane. A high rise building is a building more than 70 feet in height above grade plane. Building height per IBC is defined as the vertical distance from the grade plane to the average height of the highest roof surface. The grade plane elevation of the East Parcel Building is at Elevation = 27’-7 1/4". The height from grade plane to the average of the highest roof surface is 60'-1”. The grade plane elevation of the West Parcel Building is at Elevation =27’-7 3/4". The height from grade plane to the average of the highest roof surface is 58’-7”. Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:03:57 PM3/32" = 1'-0"A202BuildingElevationsSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1South Street North Elevation3/32" = 1'-0"2South ElevationNo. Date Description1 01/10/23 Planning BoardRevisions1 First Floor SubfloorSecond FloorSubfloorGarage Floor PlanThird Floor SubfloorFourth FloorSubfloorMezzanine FloorSubfloor2A302E.CE.DE.EE.FE.GE.HE.IE.JE.KE.I.2E.BE.A2A301Fourth Floor PlateHeight E1EA3A3A3EA3A3EA3A3EA3C2C2C2C2A2A2A2A2DDDDBBBBBBBBA2B2IE123E Average ofHighest RoofA2B2A2B2Elevation =E Average Grade Plane27' -7 1/4"Building Height60' - 1"G2G3G2----First Floor SubfloorSecond FloorSubfloorGarage Floor PlanThird Floor SubfloorFourth FloorSubfloorMezzanine FloorSubfloor2A302W.DW.CW.BW.AW.EW.FW.GW.HW.IW.JW.KW.LW.J.2CC2C2C2GW308W208W108W122CCCCCCCW132W232W332CA2A2A2A2BBBBA2A2A2A2BBBBA2A2A2A2DDDDA2A2A2A2W Average ofHighest RoofElevation =W Average Grade Plane27' -7 3/4"Building Height58' - 7"Note:These buildings have been designed to be classified as mid-rise buildings. MA amendments to the IBC define mid-rise as a building that does not exceed 70 ft above the grade plane. A high rise building is a building more than 70 feet in height above grade plane. Building height per IBC is defined as the vertical distance from the grade plane to the average height of the highest roof surface. The grade plane elevation of the East Parcel Building is at Elevation = 27’-7 1/4". The height from grade plane to the average of the highest roof surface is 60'-1”. The grade plane elevation of the West Parcel Building is at Elevation =27’-7 3/4". The height from grade plane to the average of the highest roof surface is 58’-7”. Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:04:03 PM3/32" = 1'-0"A203BuildingElevationsSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1East Elevation of 110 School Street3/32" = 1'-0"2West Elevation of 115 School StreetNo. Date Description1 01/10/23 Planning BoardRevisions1 First Floor SubfloorSecond FloorSubfloorGarage Floor PlanThird Floor SubfloorFourth FloorSubfloorMezzanine FloorSubfloorE.2E.1E.3E.4E.5E.8E.71A302E.6AA2AAA2AAA2AAA2AA2A2A2A2DDDA3A3A3A3E480E380E280E180E159E259E359E459E124E134E234E334E434E Average ofHighest RoofElevation =E Average Grade Plane27' -7 1/4"Building Height60' - 1"CCCFirst Floor SubfloorSecond FloorSubfloorGarage Floor PlanThird Floor SubfloorFourth FloorSubfloorMezzanine FloorSubfloorE.2E.1E.3E.4E.51A302E.6Fourth Floor PlateHeight E1E121E122A2IA2A2Elevation =E Average Grade Plane27' -7 1/4"Note:These buildings have been designed to be classified as mid-rise buildings. MA amendments to the IBC define mid-rise as a building that does not exceed 70 ft above the grade plane. A high rise building is a building more than 70 feet in height above grade plane. Building height per IBC is defined as the vertical distance from the grade plane to the average height of the highest roof surface. The grade plane elevation of the East Parcel Building is at Elevation = 27’-7 1/4". The height from grade plane to the average of the highest roof surface is 60'-1”. The grade plane elevation of the West Parcel Building is at Elevation =27’-7 3/4". The height from grade plane to the average of the highest roof surface is 58’-7”. Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:04:07 PM3/32" = 1'-0"A204BuildingElevationsSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1North Elevation of 110 School Street Buildings 02, 04, & 063/32" = 1'-0"2South Elevation of 110 School Street Building 08No. Date Description1 01/10/23 Planning BoardRevisions1 W.2W.3W.4W.5W.1W.6E.2E.1E.3E.4E.5E.8E.7E.6Fourth Floor EaveHeight EastFourth Floor EaveHeight West9' - 5"W Average ofHighest RoofE Average ofHighest RoofElevation =E Average Grade Plane27' -7 1/4"Elevation =W Average Grade Plane27' -7 3/4"41' - 0 3/4"Building Height60' - 1"38' - 7 1/2"Building Height58' - 7"Mezzanine EaveHeightMezzanine EaveHeight11' - 10"Note:These buildings have been designed to be classified as mid-rise buildings. MA amendments to the IBC define mid-rise as a building that does not exceed 70 ft above the grade plane. A high rise building is a building more than 70 feet in height above grade plane. Building height per IBC is defined as the vertical distance from the grade plane to the average height of the highest roof surface. The grade plane elevation of the East Parcel Building is at Elevation = 27’-7 1/4". The height from grade plane to the average of the highest roof surface is 60'-1”. The grade plane elevation of the West Parcel Building is at Elevation =27’-7 3/4". The height from grade plane to the average of the highest roof surface is 58’-7”. Check by:Scale:Date:Drawn by:Project:13"=1'-0"0SCALE21-1/2"=1'-0"10SCALE1"=1'-0"210SCALE31/2"=1'-0"3'2'1'012SCALE8420SCALE 1/4"=1'-0"201050SCALE 1/8"=1'-0"IF THIS SHEET IS NOT 24 X 36 IT IS A REDUCED SCALE PRINT - SCALE ACCORDINGLY6'Plot Date:ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS.© 2022 Gienapp Architects, LLCF:\701-750\737 Hyannis Dockside Condominiums\737.1 Dockside Condominiums\737.1 DRAWINGS AND SPECIFICATIONS\737.1 Working Set\737.1 Hyannis Dockside Condos 01092023 4 Stories.rvt1/13/2023 5:04:12 PM3/32" = 1'-0"A210Building EaveHeightsSKMN737.1Hyannis Dockside Condos110 School Street & 115 School StreetStreet, Hyannis, MA 02601Progress Set06/29/223/32" = 1'-0"1South Street North Elevation - Eave HeightsNo. Date Description1 01/10/23 Planning BoardRevisions1