Loading...
HomeMy WebLinkAboutMinor Mod 243 Indian TrailTown of Barnstable Old King's Highway Historic District Committee 367 Main Street, Hyannis, Massachusetts 02601 Telephone: (508) 862-4787 Email: erica.brown@town.barnstable.ma.us Application, MINOR MODIFICATION 972 CMR Rules and Regulations, Section 1.03(2) 1:03: General Procedures (2.) (a.)Only minor changes may be approved by the Committee without the filing of a new application and a new hearing. Minor changes include alterations that can be done without a detrimental impact on the overall appearance of the project such as altering a single window or door change or a minor change of colors. All minor changes by amendment will require the local Committee’s or it’s designee’s approval. Submit one (1) copy of the application and supporting materials and documentation. Date Map & Parcel Homeowner Phone Street address Email Village Mailing address Signature Date of Approved Certificate of Appropriateness Proposed Minor Modification APPROVED DENIED Chair Notes: _________________________________________________________________________________________________________ cc: Brian Florence, Building Commissioner 337/02509/11/2023 Magruder Real Estate Trust/Edward Hurwitch 617-642-8765 243 Indian Trail Barnstable n.hurwitch@gmail.com 9/14/2022 Box 607 Barnstable 02630 Garage dormer moved out 3' to align with eastern first floor of garage. Man-door added to east side of the garage. See attached plan revision. THE SCOPE OF WORK CONSISTS OF GARAGE AND MASTER SUITE ADDITION. CODE COMPLIANCE: THE CONTRACTOR, SUBCONTRACTORS, AND OTHERS PERFORMING WORK ON THIS PROJECT SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND REGULATIONS, AND ALL OTHER AUTHORITIES HAVING JURISDICTION. ALL WORK IS TO BE PERFORMED BY CONTRACTORS HAVING A MA LICENSE AND/OR LICENSES REQUIRED BY THE LOCAL JURISDICTIONS. ENERGY CODE COMPLIANCE: ALL NEW CONSTRUCTION SHALL CONFORM TO MASSACHUSETTS STATE ENERGY CODE. FLD RESPONSIBILITY IS LIMITED TO THE CONTENTS OF THESE CONSTRUCTION DOCUMENTS ONLY. THE DESIGNER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTORS' EXECUTION OF WORK NOT IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. CONTRACTOR SHALL OBTAIN ALL BUILDING PERMITS REQUIRED FOR THE CONTRACT, AND SHALL OBTAIN THE CERTIFICATE OF OCCUPANCY UPON COMPLETION OF THE WORK. CONTRACTOR SHALL PAY ALL FEES, GIVE ALL NOTICES, PREPARE AND FILE ALL REQUIRED DRAWINGS, AND SCHEDULE All INSPECTIONS TO OBTAIN All PERMITS AND CERTIFICATES OF APPROVAL REQUIRED FOR THE WORK. CONTRACTOR SHALL HAVE AN EXPERIENCED SUPERINTENDENT ON THE PREMISES AT All TIMES WHEN WORK IS IN PROGRESS. CONTRACTOR SHALL BE LICENSED AND INSURED FOR LIABILITY AND PROPERTY DAMAGE AS REQUIRED BY LAW AND THE OWNER, AND SHALL SUBMIT PROOF OF SUCH TO THE OWNER UPON REQUEST. CONTRACTOR SHALL PROVIDE A SCHEDULE FOR THE WORK, BROKEN DOWN BY TRADES AND MAJOR MILESTONE DATES. CONTRACTOR SHALL WORK CLOSELY WITH OWNER TO SCHEDULE ALL OWNER-SUPPLIED/CONTRACTOR-INSTALLED MATERIALS, FIXTURES AND/OR EQUIPMENT, AND SHALL WORK CLOSELY WITH All OWNER'S VENDORS, TO ENSURE ADEQUATE TIME HAS BEEN ALLOTTED FOR ORDERING AND DELIVERING ALL ITEMS TO THE SITE. CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL OWNER-SUPPLIED MATERIALS ONCE DELIVERED, AND SHALL PROVIDE SITE STORAGE AND PROTECTION, IN ADDITION TO INSTALLATION. SUBSTITUTIONS: CHANGES OR SUBSTITUTIONS ARE PERMISSIBLE ONLY WITH THE PRIOR WRITTEN APPROVAL AND AUTHORIZATION OF FLD. PROVIDE HARD-WIRED SINGLE STATION SMOKE DETECTORS IN EACH BEDROOM, OUTSIDE EACH SEPARATE SLEEPING AREA, IN THE GARAGE AND ON EACH FLOOR AS PER MASSACHUSETTS BUILDING CODE. WORK SHOWN OR NOTED IS NEW UNLESS SPECIFICALLY NOTED OR OTHERWISE INDICATED AS EXISTING. WHERE "MATCH EXISTING' IS INDICATED, NEW CONSTRUCTION OR FINISHES, AS APPROPRIATE TO THE NOTE, SHALL MATCH THE EXISTING IN EVERY PARTICULAR. BEFORE BEGINNING WORK, AND THROUGHOUT THE COURSE OF THE WORK, THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING AND VERIFYING THE LOCATION AND CONDITION OF ALL ITEMS AFFECTED BY THE WORK UNDER THIS CONTRACT, AND SHALL REPORT BACK TO THE ARCHITECT ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. DISCREPANCIES: WHEN DISCREPANCIES OCCUR BETWEEN CONSTRUCTION CONDITIONS AND THE CONSTRUCTION DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING FLD FOR CLARIFICATION OR VERIFICATION PRIOR TO PROCEEDING. BEFORE BEGINNING WORK, THE CONTRACTOR SHALL INSPECT THE EXISTING BUILDING AND DETERMINE THE EXTENT OF EXISTING FINISHES, SPECIAL TIES, CASEWORK, EQUIPMENT, AND OTHER ITEMS WHICH MUST BE REMOVED AND REINSTALLED IN ORDER TO PERFORM THE WORK UNDER THIS CONTRACT. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS WHERE WORK MUST BE PERFORMED. INCIDENTAL WORK MAY ALSO BE NECESSARY IN AREAS NOT SHOWN ON THE ARCHITECTURAL DRAWINGS DUE TO CHANGES AFFECTING EXISTING MECHANICAL, ELECTRICAL, PLUMBING, OR OTHER SYSTEMS AND CONDITIONS. SUCH INCIDENTAL WORK IS ALSO UNDERSTOOD TO BE A PART OF THIS CONTRACT. THE CONTRACTOR SHALL INSPECT ALL AREAS OF THE EXISTING BUILDING, ASCERTAIN WORK REQUIRED, AND PERFORM SUCH WORK IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS, AT NO ADDITIONAL COST. THE CONTRACTOR SHALL NOT DRILL OR CUT OUT EXISTING FLOOR JOISTS, BEAMS, COLUMNS, OR OTHER STRUCTURAL ELEMENTS, UNLESS SPECIFICALLY INDICATED ON THE CONTRACT DOCUMENTS. DRILL SLABS WHERE APPROVED. MAKE OPENINGS OF PROPER SIZE FOR CONDUITS, DUCTS, PIPES, AND OTHER ITEMS TO PASS THROUGH. All DRILLING AND NOTCHING SHALL BE REVIEWED WITH FLD / STRUCTURAL ENGINEER PRIOR TO BEING UNDERTAKEN. THE CONTRACTOR SHALL VERIFY All DRAWINGS FOR COORDINATION BETWEEN TRADES; PROVIDE AND/OR INSTALL ANCHORS, INSERTS, HANGERS, ETC., AS REQUIRED FOR VARIOUS TRADES. All EXISTING WORK TO REMAIN IS TO BE PROPERLY PROTECTED FROM DAMAGE DURING All PHASES OF WORK. EXISTING SURFACES DAMAGED OR NEWLY EXPOSED DURING THE EXECUTION OF WORK ARE TO BE REPAIRED, PATCHED, AND FINISHED, OR REFINISHED AS APPLICABLE, TO MATCH ADJACENT EXISTING FINISHES. WHERE PERMANENT REMOVAL OF EXISTING MILL WORK, CASEWORK, CABINETRY, ACCESSORIES, EQUIPMENT, OR FURNISHINGS ARE TO REMAIN EXPOSED, PATCH PREVIOUSLY CONCEALED SURFACES TO MATCH ADJACENT EXPOSED SURFACES. WHERE SUCH SURFACES ARE SCHEDULED TO RECEIVE NEW FINISHES, PREPARE THE SURFACES TO RECEIVE THE NEW FINISHES. WHERE CUTTING OF EXISTING SURFACES OR REMOVAL OF EXISTING FINISHES IS REQUIRED TO PERFORM THE WORK UNDER THIS CONTRACT, AND A NEW FINISH IS INDICATED, FILL RESULTING OPENINGS AND PATCH THE SURFACE TO MATCH ADJACENT SURFACES. WHERE CONDUITS, DUCTS, PIPES, AND SIMILAR ITEMS ARE SHOWN TO BE INSTALLED IN EXISTING WALLS OR PARTITIONS, NEATLY CHASE THE WALLS OR PARTITIONS, INSTALL THE ITEMS, AND PATCH THE WALLS OR PARTITIONS TO MAKE THE INSTALLATION NOT DISCERNIBLE IN THE FINISHED WORK USE OF DRAWINGS: THE CONTRACTOR SHALL USE FIGURE MEASUREMENTS NOTED ON THE DRAWINGS ONLY. MEASUREMENTS SHALL NOT BE SCALED FROM THE DRAWINGS. IF ADDITIONAL INFORMATION IS REQUIRED, THE CONTRACTOR SHALL NOTIFY FLD PRIOR TO PROCEEDING. THE CONTRACTOR SHALL NOT INTERPOLATE DIMENSIONS OR INFORMATION FROM THE DRAWINGS. DIVISION 1: GENERAL REQUIREMENTS 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 1.12 1.13 1.15 1.16 1.17 1.18 1.19 1.14 1.20 1.21 1.22 1.23 1.24 1.25 PROTECTION OF EXISTING: DURING THE CONSTRUCTION PROCESS, REASONABLE CARE SHALL BE TAKEN TO PROTECT ALL EXISTING STRUCTURES FROM DAMAGE, AND TO PRESERVE AND MAINTAIN ALL EXISTING TREES, SHRUBS, AND FOLIAGE. PROVIDE EXTERIOR AND INTERIOR SHORING, BRACING, OR SUPPORT AS REQUIRED TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURES AND CONSTRUCTION TO REMAIN. EXCAVATION SHALL BE ACCOMPLISHED TO SATISFY THE REQUIREMENTS AND INTENT OF THE CONTRACT DOCUMENTS, INCLUDING EXCAVATION FOR FOUNDATION AND TRENCHING FOR UTILITIES AND OTHER MECHANICAL, PLUMBING, AND ELECTRICAL INSTALLATIONS. IF ROCK OR CLAY IS ENCOUNTERED, NOTIFY BOTH THE OWNER AND FLD IMMEDIATELY BEFORE PROCEEDING WITH FURTHER WORK. AT NO TIME SHALL BULLDOZERS, TRUCKS, OR OTHER HEAVY EQUIPMENT BE PERMITTED TO APPROACH FOUNDATION WALLS CLOSER THAN EIGHT (8) FEET. All EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF 4'-0" BELOW FINAL GRADE ON UNDISTURBED SOIL OR COMPACTED STRUCTURAL FILL. STEPPED FOOTINGS AS REQUIRED TO MATCH EXISTING BUILDING FOOTING ELEVATIONS AS SPECIFIED BELOW. ELEVATIONS OF BOTTOM OF FOOTINGS SHOWN ON PLANS ARE FOR ESTIMATING PURPOSES AND SHALL BE ADJUSTED TO REQUIRED BE.ARING STRATA AS FOUND UPON EXCAVATION. FOOTINGS SHALL NOT BE PLACED ON ROCK WHOSE SURFACE SLOPES MORE THAN 10 PERCENT OR WHOSE BEARING CAPACITY IS LESS THAN 6 TONS PER SQUARE FOOT. WHERE FOOTINGS ARE STEPPED, FOOTING LEVELS ARE TO BE STEPPED UP OR DOWN AT A 30 DEGREE ANGLE. TOP OF FOOTING SHALL BE INSTALLED LEVEL. BOTTOM OF FOOTING MAY BE SLOPED AT MAXIMUM 1 FOOT VERTICAL TO 10 FEET HORIZONTAL. FOUNDATIONS HAVE BEEN DESIGNED TO AN ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. SHOULD CONDITIONS VARY FROM THOSE ASSUMED, THE ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUATION OF WORK. EVIDENCE OF UNSUITABLE MATERIAL SHALL BE CAUSE FOR REDESIGN OF FOUNDATION. AREAS UNDER CONCRETE SLABS ARE TO BE BACK FILLED WITH CLEAN, FREE-DRAINING MATERIAL AND BE FULLY COMPACTED TO 95 PERCENT OF PROCTOR DENSITY POWER TAMPER. PLACE FILL IN 12' MAXIMUM LIFTS. DO NOT BACK FILL AGAINST FOUNDATION WALLS UNTIL MORTAR AND/OR CONCRETE HAVE ATTAINED MAXIMUM STRENGTH. FILL SHALL BE FREE FROM DEBRIS, SNOW, ICE, WATER, AND ORGANIC MATERIAL. SLOPE GROUND AROUND FOUNDATIONS. DIVISION 2: SITE WORK NO CONCRETE SHALL BE POURED SUBJECT TO FREEZING CONDITIONS OR FROZEN GROUND TWENTY-EIGHT DAY COMPRESSION STRENGTH FOR CONCRETE SHALL BE AS FOLLOWS: 3.2.1 FOOTINGS: 3,000 PSI 3.2.2 SLAB ON GRADE: 3,500 PSI 3.2.3 WALLS: 3,000 PSI MAXIMUM CONCRETE SLUMP SHALL BE 4 INCHES, AND MAXIMUM WATER-CEMENT RATIO SHALL BE 0.45. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DESIGN OF CONCRETE MIXES AND FOR MAINTAINING STRENGTH AND PROPER SLUMP DURING CONSTRUCTION. CONCRETE MIXES SHALL BE DESIGNED IN ACCORDANCE WITH METHODS OUTLINED IN ACI AND AS MODIFIED BY THE GOVERNING CODE. CONCRETE SHALL BE PLACED AND CONSOLIDATED IN SUCH A WAY TO ELIMINATE VOIDS, HONEYCOMBING, SEPARATION OF CONSTITUENTS, ETC ... PER ACCEPTED ACI PRACTICE. POOR PLACEMENT, REGARDLESS OF 28-DAY STRENGTH RESULTS IF TESTED, WILL RESULT IN REMEDIAL WORK. ALL VERTICAL SURFACES OF CONCRETE SHALL BE FORMED FOR WALLS. All REINFORCEMENT SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH ACI MANUAL OF STANDARD PRACTICE. All REINFORCING BARS SHALL BE OF NEW BILLET STEEL CONFORMING TO ASTM A615, GRADE 60. TIES AND STIRRUPS MAY BE GRADE 40. ALL WELDED WIRE MESH SHALL CONFORM TO ASTM A185, AND SHALL HAVE A MINIMUM YIELD STRENGTH OF 70,000 PSI. REINFORCING STEEL SHALL BE PLACED TO PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER: 3.9.1 FOOTINGS: 3" 3.9.2 SLAB ON GRADE: 1-1/2" 3.9.3 WALLS: 2" STEEL CONCRETE REINFORCING SHALL BE: 3.10.1 BARS: BILLET STEEL DEFORMED BARS, ASTM A615, SIZES AS NOTED ON DRAWINGS. 3.10.2 WELDED WIRE FABRIC (WWF): ASTM A185, SIZES AS NOTED ON DRAWINGS. ALL BEARING GROUT SHALL BE NON-SHRINK, NON-METALLIC WITH A MINIMUM COMPRESSIVE STRENGTH OF 5,000 PSI. DIVISION 3: CONCRETE All FRAMING SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF "NATIONAL DESIGN SPECIFICATION FOR STRESS GRADED LUMBER AND ITS FASTENINGS," AS PUBLISHED BY THE NATIONAL LUMBER MANUFACTURERS ASSOCIATION. All LUMBER MATERIALS USED IN THE BUILDING SHALL BE GOOD, SOUND, DRY MATERIAL, FREE FROM ROT, LARGE AND LOOSE KNOTS, SHAKES AND OTHER IMPERFECTIONS WHEREBY THE STRENGTH MAY BE IMPAIRED, AND OF SIZES INDICATED ON THE DRAWINGS. All WORKMANSHIP, INCLUDING NAILING, BLOCKING, BRIDGING, ETC., SHALL CONFORM TO STATE BUILDING CODES. PROVIDE LEDGER, BLOCKING, NAILERS, AND ROUGH FRAMING HARDWARE AS REQUIRED. FRAMING SHALL BE SPF N0.1 / N0.2 Fb SINGLE= 875 PSI e=1.4 x 10"6 U.O.N. WHERE NOTED SELECT USE SPF SELECT Fb SINGLE= 1250 PSI, E=1.5x10'6 LVL'S SHALL BE VERSLAM 2.0 • 3100 Fb = 3100 PSI E=2.0 x 10"6 PSI PROVIDE FASTENERS IN ACCORDANCE WITH MASSACHUSETTS BUILDING CODE, & PROVIDE HURRICANE TIES AT JOISTS, SILLS, STUDS AND RAFTERS AT 4'-0' O.C. MINIMUM FOR ROOF TO FOUNDATION. PROVIDE FIRE BLOCKING PER MA CMR 5602.8. PROVIDE BRACING IN ACCORDANCE WITH MASSACHUSETTS BUILDING CODE. All LUMBER SHALL BEAR VISIBLE GRADE STAMPING. JOISTS SHALL BE FASTENED TO STEEL BEAMS BY EITHER OF TWO ACCEPTABLE METHODS, AS FOLLOWS: (OR DETAIL SHOWN) A) BEAM UNDER: A CONTINUOUS 2" X 6" NAILER PLATE SHALL BE BOLTED TO TOP FLANGE OF STEEL WITH 1/2" DIAMETER GALVANIZED STEEL BOLTS AT 4'-0" ON CENTER. ON Al TERNA TE SIDES OF WEB. JOISTS SHALL BE TOE-NAILED TO PLATE WITH 3-8D NAILS PER JOIST. JOISTS FRAMING FROM OPPOSITE SIDES SHALL LAP AT LEAST SIX INCHES, BE SPIKED TOGETHER AND BLOCKED. B) BEAM FLUSH: CONTINUOUS 2x WEB BLOCKING SHALL BE THROUGH BOLTED 1/2" DIAMETER GALVANIZED BOLTS AT 4'-0' ON CENTER STAGGERED. JOISTS TO BE CONNECTED TO INFILL BLOCKING WITH JOIST HANGERS . All BEAMS, JOISTS, AND RAFTERS ARE TO BE SET WITH NATURAL CROWN UP. PROVIDE A (2) 2" X 8" MINIMUM HEADER WHERE ROUGH OPENING DOES NOT EXCEED 3'-0". PLYWOOD FOR SUBFLOOR SHEATHING SHALL BE APA C-C PLUGGED EXTERIOR OR APA UNDERLAYMENT EXTERIOR. INDEX STAMP SHALL BE VISIBLE ON ALL SHEETS. PLYWOOD USED FOR WALL AND ROOF SHEATHING SHALL BE APA RATED SHEATHING, 24/0, 5/8" EXTERIOR AT ALL NEW CONSTRUCTION, AND 1/2" AT EXISTING CONSTRUCTION TO MATCH AND ALIGN WITH EXISTING. Pl YWOOD SHALL BE NAILED TO JOISTS WITH SD COMMON NAILS AT 6" ON CENTER AT EXTERIOR EDGES. AND 12'' ON CENTER AT INTERMEDIATE SUPPORTS. USE PLYCLIPS OR OTHER SUPPORT FOR ALL PLYWOOD SHEATHING. PLACE FACE GRAIN IN DIRECTION OF SPAN (TRANSVERSE TO JOIST SPAN). LEAVE 1/16" SPACE AT ALL PLYWOOD PANEL END JOINTS, AND 1/8" SPACE AT ALL PANEL EDGE JOINTS. JOIST HANGERS, FRAMING ANCHORS AND RAFTER ANCHORS SHALL BE MINIMUM 18 GAUGE PRIMED GALVANIZED STEEL AS MANUFACTURED BY TECO, SIMPSON, OR APPROVED EQUAL. SPECIAL NAILS AS SUPPLIED BY MANUFACTURER SHALL BE USED FOR REQUIRED NAILING. METAL CROSS BRIDGING SHALL BE GALVANIZED STEEL AS MANUFACTURED BY TECO, SIMPSON, OR APPROVED EQUAL, AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' DIRECTIONS. PROVIDE "X" BRIDGING OR SOLID BLOCKING 8'--0" ON CENTER. BOTTOM ENDS OF BRIDGING SHALL NOT BE NAILED UNTIL AFTER SUBFLOORS AND PLYWOOD ARE LAID. PROVIDE DOUBLE JOISTS UNDER All PARTITIONS PARALLEL TO JOISTS. WHERE SHEATHING IS NOT Pl YWOOD, DIAGONAL BRACING SHALL BE LET IN AT EXTERIOR CORNERS OR BRACE CORNERS WITH 1/2" CDX Pl YWOOD 4'-0' IN EACH DIRECTION. DOOR AND WINDOW CASINGS, FASCIA BOARDS, AND DECORATIVE WOOD ITEMS SHALL BE PAINT GRADE WOOD TO MATCH EXISTING, OR AS SHOWN OR CALLED FOR ON DRAWINGS. NEW WOOD BOARD AND BA TON SIDING AT EXTERIOR WALLS TO BE 3/4" THICK ROUGH CUT CEDAR, WITH BOARD EXPOSURE TO MATCH EXISTING, AND AS SHOWN ON THE ELEVATION DRAWINGS. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE MASONRY UNITS SHALL BE PRESSURE TREATED. PRESERVATIVE TREATMENT FOR WOOD SHALL BE APPROVED BY LOCAL AUTHORITIES HAVING JURISDICTION. PROVIDE (3) 2" X 6" SPIKED AT BEARING POINTS OF ALL TRIPLE-FRAMING MEMBERS, UNLESS OTHERWISE NOTED. PROVIDE DOUBLE STUD EACH SIDE AT ALL WALL OPENINGS, UNLESS OTHERWISE NOTED. PROVIDE ALL LVL SHALL BE VERSALAM OR EQUAL 1.7E-2650Fb DIVISION 6: WOOD AND PLASTICS ALL NEW ASPHALT SHINGLE ROOFING AND UNDERLAYMENT SHALL COMPLY WITH MASSACHUSETTS BUILDING CODE. UNDERLAYMENT AND HIGH WIND: UNDERLAYMENT SHALL BE APPLIED WITH CORROSION-RESISTANT FASTENERS IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. FASTENERS ARE TO BE APPLIED ALONG THE OVERLAP NOT FARTHER APART THAN 36 INCHES ON CENTER. DIVISION 7: THERMAL AND MOISTURE PROTECTION 2.1 2.2 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10 6.11 6.12 6.13 6.14 6.15 6.16 6.17 6.18 6.19 6.20 6.21 6.22 6.23 6.24 6.25 6.26 6.27 6.28 6.29 7.1 7.2 HURWITCH ADDITION 243 INDIAN TRAIL, BARNSTABLE, MA ALL NEW WORK SHALL COMPLY WITH THE LATEST EDITION OF THE MASSACHUSETTS STATE BUILDING CODE AND ENERGY CONSERVATION CODE. ALL WORK SHALL COMPLY WITH ALL PUBLIC SAFETY REGULATIONS OF AGENCIES HAVING JURISDICTION, INCLUDING ALL OSHA REQUIREMENTS. DESIGN CONFORMS TO THE FOLLOWING: MASSACHUSETTS BUILDING CODE, 9TH EDITION + CURRENT AMENDMENTS - INTERNATIONAL RESIDENTIAL CODE, 2015 EDITION - AMERICAN FOREST AND PAPER ASSOCIATION , AMERICAN WOOD COUNCIL, AND INTERNATIONAL CODE COUNCIL "140 MPH EXPOSURE C", WOOD FRAME CCNSTRUCTION MANUAL (WFCM) AMERICAN WOOD COUNCIL "PRESCRIPTIVE RESIDENTIAL WOOD DECK". CONSTRUCTION GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS: 140 MPH WIND ZONE; MASSACHUSETTS CHECKLIST FOR COMPLIANCE (780 CMR 5301.2.1.1 ). 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) NOTES:DESIGNER: FINE LINE DESIGN 3826 MAIN ST, BARNSTABLE, MA kevin@finelinearchitectural.com A1 ELEVATIONS A2 ELEVATIONS DRAWING LIST COVER S1 S2 FOUNDATION PLAN FIRST FLOOR FRAMING PLAN A3 FIRST FLOOR PLAN A4 SECOND FLOOR PLAN S3 S4 SECOND FLOOR FRAMING PLAN ROOF FRAMING PLAN S5 SECTIONS S6 DETAILS A1 ELEVATIONS NOTES: DATE: 8/24/23 SHEET # SET ISSUE DATES ISSUEDATE DESCRIPTIONDATE 2 OF 21 #243 INDIAN TRAILBARNSTABLE MAFINE LINE design REVISIONS 508.420.1296 3826 MAIN STREET BARNSTABLE MA www.FineLineArchitecturalDesign.com ADDITION 10/14/22 PERMIT SET FOR CONSTRUCTION 4/25/23 REVISE FOR SETBACK NON-STRUCTURAL 7/28/23 I-JOISTS @ GARAGE SECOND FLOOR + 16' GARAGE DOOR 8/22/23 GARAGE DORMER W/ 6" INSET NEW ENTRY GARAGE ADDITION NEW ROOF DECK 21'-8" +/-3 12 3 12 REMOVE CHIMNEY 312 C 1 GARAGE ADDITION NEW FIRST FLOOR MASTER SUITE 312 312 3 12 REMOVE CHIMNEY 3 12 C DD 3 SCALE: 1/4" = 1'-0"1 REVISED SOUTH ELEVATION SCALE: 1/4" = 1'-0"2 REVISED SOUTH ELEVATION A2 REVISED ELEVATION NOTES: DATE: 8/24/23 SHEET # SET ISSUE DATES ISSUEDATE DESCRIPTIONDATE 3 OF 21 #243 INDIAN TRAILBARNSTABLE MAFINE LINE design REVISIONS 508.420.1296 3826 MAIN STREET BARNSTABLE MA www.FineLineArchitecturalDesign.com ADDITION 10/14/22 PERMIT SET FOR CONSTRUCTION 4/25/23 REVISE FOR SETBACK NON-STRUCTURAL 7/28/23 I-JOISTS @ GARAGE SECOND FLOOR + 16' GARAGE DOOR 8/22/23 GARAGE DORMER W/ 6" INSET GARAGE ADDITION NEW FIRST FLOOR MASTER SUITE ARCHITECTURAL ASPHALTSHINGLES TO MATCH EXISTING 1x5 WHITE AZEK WINDOW TRIM TYP. D D D 5 A A A A A NOTE: WINDOWS NOTED ARE MANUFACTURED BY ANDERSEN. G.C. TO CHECK SIZE AND LOCATION PRIOR TO CONSTRUCTION. NOTIFY FLD FOR SCHEDULE TO BE UPDATED IF ALTERNATE MANUFACTURER IS USED. WINDOW SCHEDULE ID QUANTITY SIZE UNIT R.O.COMMENT 5 2 28 3/8"x28 3/8" B 28 7/8"x28 7/8" 28 3/8"x28 3/8"28 7/8"x28 7/8" 29 5/8"x56 7/8"30 1/8"x56 7/8"10 29 5/8"x52 7/8"30 1/8"x52 7/8"3 EXTERIOR DOOR SCHEDULE ID QUANTITY 1 1 DOOR SIZE WIDTH HEIGHT 3'-0"6'-8" COMMENT ANDERSEN FWG60611 L WHITE SLIDER 15 LITE6'-0"6'-11" TBD 400 SERIES WHITE AWN AW251 6 LITE 400 SERIES WHITE DH TW2446 6/6 LITE 400 SERIES WHITE AWN AW251 6 LITE FIXED 400 SERIES WHITE DH TW2442 6/6 LITE 1 16'-0"7'-0"CLOPAY O.H. W/ 12" TRANSOM 2 3'-0"6'-8"ANDERSEN FWG 3168 WHITE FULL GLASS 15 LITE 1 2'-8"6'-8"THERMA TRU 9 LITE C D E F 1 2 3 4 5 A SCALE: 1/4" = 1'-0"3 REVISED EAST ELEVATION A3 REVISED FIRST FLOOR PLAN NOTES: DATE: 8/24/23 SHEET # SET ISSUE DATES ISSUEDATE DESCRIPTIONDATE 4 OF 21 #243 INDIAN TRAILBARNSTABLE MAFINE LINE design REVISIONS 508.420.1296 3826 MAIN STREET BARNSTABLE MA www.FineLineArchitecturalDesign.com ADDITION 10/14/22 PERMIT SET FOR CONSTRUCTION 4/25/23 REVISE FOR SETBACK NON-STRUCTURAL 7/28/23 I-JOISTS @ GARAGE SECOND FLOOR + 16' GARAGE DOOR 8/22/23 GARAGE DORMER W/ 6" INSET 22'-0" 9'-5 3/4"21'-0"6'-4"17'-3 1/4"6'-2 3/4" EXISTING GARAGE ADDITION NEW FIRST FLOOR MASTER SUITE EXISTING2'-6"16'-0"2'-6" 2'-8"2'-8"3'-6"18'-6"3'-3 3/4"3'-0"6'-1"3'-0"3'-0"3'-0"2'-7 1/2"7'-0"8'-9"24'-0"28'-0"4'-9"7'-3"7'-3"4'-9"1'-8"7'-0"6'-11"12'-5 1/4"24'-2"3'-8"8'-9 1/2"9'-7 1/2"2'-1"52'-0"3'-0"6'-0"5'-0" S CO HT SMOKE DETECTOR CARBON MONOXIDE SENSOR HEAT SENSOR HT HT S CO S D D D D D D D D D A DINING ROOM PANTRY KITCHENENTRY LIVING ROOM 1/2 BATH GARAGE COVERED PORCH UP UP DN PANTRY CL DINING RAMP UP UP BATH WIC OUTSIDE SHOWER PORCH 1 3 4 1:12FIRE RATED DN TEMPERED ENTRY EXISTING REMOVE CHIMNEY REF ISLAND CL BENCH CAB 30 FT SETBACK5 STACK W&D 3068 PKT3068 PKT 3068 PKT LIN CAB LIN CAB MASTER BEDROOM SCALE: 1/4" = 1'-0"1 REVISED FIRST FLOOR PLAN A4 REVISED SECOND FLOOR PLAN NOTES: DATE: 8/24/23 SHEET # SET ISSUE DATES ISSUEDATE DESCRIPTIONDATE 5 OF 21 #243 INDIAN TRAILBARNSTABLE MAFINE LINE design REVISIONS 508.420.1296 3826 MAIN STREET BARNSTABLE MA www.FineLineArchitecturalDesign.com ADDITION 10/14/22 PERMIT SET FOR CONSTRUCTION 4/25/23 REVISE FOR SETBACK NON-STRUCTURAL 7/28/23 I-JOISTS @ GARAGE SECOND FLOOR + 16' GARAGE DOOR 8/22/23 GARAGE DORMER W/ 6" INSET EXISTING ROOF DECK GARAGE ADDITION MASTER SUITE ADDITION 10'-6"10'-6"9'-11 1/2"14'-1/2"6'-10 3/4"7'-1 3/4"3'6'-4 1/2" 3'-4"4'6" 21'24'S CO HT SMOKE DETECTOR CARBON MONOXIDE SENSOR HEAT SENSOR S CO C C C OWNER'S ROOM GUEST'S ROOM BATH NURSERY NURSE'S ROOM MAID'S BATH BATH BEDROOM CL CL CL CL DN DN DN WET BAR PROPOSED 1/2 BATH 2 2 4' KNEE WALLDORMER WALLA A A B B A 4'-9"7'-3"7'-3"4'-9"2'3' PROPOSED ADDITION ROOF DECK ADDITION SCALE: 1/4" = 1'-0"2 REVISED SECOND FLOOR PLAN