HomeMy WebLinkAboutCOA 260 Church StreetNJ, Electrical Contractor business permit number 34EB01547400
NJ, HIC reg. # 13VH01244300
For other jurisdictions, please visit: http://www.trinity-solar.com/about-us/locations-and-licenses
Corporate Headquarters 1-877-SUN-SAVES
2211 Allenwood Road Ph: 732-780-3779
Wall, New Jersey 07719 Fax: 732-780-6671
www.trinity-solar.com
FOR INFORMATION ABOUT CONTRACTORS AND THE CONTRACTORS’ REGISTRATION ACT,
CONTACT THE NEW JERSEY DEPARTMENT OF LAW AND PUBLIC SAFETY,
DIVISION OF CONSUMERS AFFAIRS AT 1-888-656-6225.
Date
__________________________________
Print Name
__________________________________
Customer Signature
__________________________________
Name on Electric Utility Account: __________________
Electric Utility Account No.: ______________________
Electric Utility Company:________________________
given for my own convenience and benefit in order to expedite the approvals processes.
solar transaction and are not a condition of the related solar agreement included herewith but are being
and effect until revoked. I acknowledge that these authorizations are not required to proceed with the
Approvals Paperwork when submitted. My authorizations memorialized herein shall remain in full force
signatures to Approvals Paperwork for purposes of the foregoing. Trinity Solar will provide copies of
herewith for my signature, in furtherance of the related solar transaction, and I am providing any
certification documents (“Approvals Paperwork”), including those for which signature pages are included
documentation to, date, submit, re-submit, revise, amend and modify application, submission and
populate technical details, fill-in, edit, compile, attach drawings, plans, data sheets and other
Without limitation to the generality of the foregoing I specifically authorize Trinity Solar et al. to
permits on file for the purpose of updating/applying with an alternate subcontractor.
This authorization includes the transfer/re-administering, and/or cancellation of any existing
with any state and/or local solar incentive program.
obtaining permission and approval for interconnection with the electric utility company, and registration
Jurisdiction as required for the installation of a Photovoltaic System located on my property, applying and
limited purpose of applying for and obtaining local building and other permits from the Authority Having
subcontractors, including without limitation, _______________________, to act as my Agent for the
I hereby authorize Trinity Heating & Air, Inc. DBA Trinity Solar and its employees, agents, and
(print address)
_____________________________________________.
am the owner of the property located at address:
(print name)
I, _____________________________________,
HOMEOWNERS AUTHORIZATION FORM
CoholanKatie
Eversource
Katie Coholan
Katie Coholan
260 Church St West Barnstable MA
8/28/23
2,000.00
This map is for illustration purposes only. It is not
adequate for legal boundary determination or
regulatory interpretation. This map does not represent
an on-the-ground survey. It may be generalized, may not
reflect current conditions, and may contain
cartographic errors or omissions.
Parcel lines shown on this map are only graphic
representations of Assessor’s tax parcels. They are
not true property boundaries and do not represent
accurate relationships to physical objects on the map
such as building locations.
3330167
Feet
feetApprox. Scale: 1 inch =167
Legend
Town of Barnstable GIS Unit
367 Main Street, Hyannis, MA 02601
508-862-4624
gis@town.barnstable.ma.us
Map printed on:10/16/2023
Road Names
INSTALLATION OF NEW
ROOF MOUNTED PV SOLAR SYSTEM
260 CHURCH ST
WEST BARNSTABLE, MA 02668
41.695905619713415,-70.37408287225381
CHURCH ST
P1 ISSUED TO TOWNSHIP FOR PERMIT 9/8/2023
NO.DESCRIPTION DATE
COHOLAN, RYAN-
TRINITY ACCT #: 2023-04-866176
260 CHURCH ST
WEST BARNSTABLE, MA 02668
41.695905619713415,-70.374082872
25381
PROPOSED PV SOLAR SYSTEM
DRAWING DATE:9/8/2023
DRAWN BY:HL
REVISED BY:
DC SYSTEM SIZE:10.935kW
AC SYSTEM SIZE:10kW
MODULE COUNT:27
MODULES USED:HANWHA 405
MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405
UTILITY COMPANY:EVERSOURCE
UTILITY ACCT #:14515650084
UTILITY METER #:2300458
DEAL TYPE:SUNNOVA
P1
R
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
ROOF 1 MODULES: 0 PITCH: 34° ORIENTATION: 32°
ROOF 2 MODULES: 17 PITCH: 34
ORIENTATION: 212
ROOF 3 MODULES: 0 PITCH: 34° ORIENTATION: 119°
ROOF 4 MODULES: 0 PITCH: 34° ORIENTATION: 302°
ROOF 5 MODULES: 10 PITCH: 34
ORIENTATION: 212
ROOF 6 MODULES: 0 PITCH: 34° ORIENTATION: 299°
ROOF 7 MODULES: 0 PITCH: 14° ORIENTATION: 32°
ROOF 8 MODULES: 0
PITCH: 34° ORIENTATION: 122°
ROOF 9 MODULES: 0 PITCH: 14°
ORIENTATION: 299°
ROOF 10 MODULES: 0 PITCH: 10° ORIENTATION: 32°
ROOF 11 MODULES: 0 PITCH: 23° ORIENTATION: 321°
ROOF 12 MODULES: 0 PITCH: 23° ORIENTATION: 141°
N
S270 90
13522545
315DC
AC
D
TS
epM
41.695905619713415,-70.37408287225381
27 HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405)
1 SE10000H-US000BEi4
INSIDE OUTSIDE.
OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE.
P1 ISSUED TO TOWNSHIP FOR PERMIT 9/8/2023
NO.DESCRIPTION DATE
COHOLAN, RYAN-
TRINITY ACCT #: 2023-04-866176
260 CHURCH ST
WEST BARNSTABLE, MA 02668
41.695905619713415,-70.374082872
25381
PROPOSED PV SOLAR SYSTEM
DRAWING DATE:9/8/2023
DRAWN BY:HL
REVISED BY:
DC SYSTEM SIZE:10.935kW
AC SYSTEM SIZE:10kW
MODULE COUNT:27
MODULES USED:HANWHA 405
MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405
UTILITY COMPANY:EVERSOURCE
UTILITY ACCT #:14515650084
UTILITY METER #:2300458
DEAL TYPE:SUNNOVA
P1
NOTES:
1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
2.)
3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION.
ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING.
M
UD SP
P
DC
AC
ep
D
DC R
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
SD
TS
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS
REQUIRED CONDUCTOR AMPACITY PER STRING
[NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A
AWG #10, DERATED AMPACITY
AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96
RACEWAY DERATING = 4 CCC: 0.80
(40*.96)0.80 = 30.72A
30.72A >_ 18.75A, THEREFORE WIRE SIZE IS VALID
TOTAL AC REQUIRED CONDUCTOR AMPACITY
42.00A*1.25 = 52.50A
AWG #6, DERATED AMPACITY
AMBIENT TEMP: 30°C, TEMP DERATING: 1.0
RACEWAY DERATING <_ 3 CCC: N/A
75A*1.0 = 75A
75A >_ 52.50A, THEREFORE AC WIRE SIZE IS VALID
CALCULATION FOR PV OVERCURRENT PROTECTION
TOTAL INVERTER CURRENT: 42.00A
42.00A*1.25 = 52.50A
--> 60A OVERCURRENT PROTECTION IS VALID
ARRAY CIRCUIT WIRING NOTES
1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY
FOR DETERMINING ONSITE CONDITIONS AND
EXECUTING INSTALLATION IN ACCORDANCE WITH
NEC 2020
2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON
ASHRAE MINIMUM MEAN EXTREME DRY BULB
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT
TEMP = -16°C
3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED
ON ASHRAE HIGHEST MONTH 2% DRY BULB
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP =
33°C
4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN
TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED
STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9
CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED
SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING
THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS
(ALL OF UNITED STATES)
5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS
SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT
CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH
NEC 690.12(A) THROUGH (D)
6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED
TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC
SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41 (A)(4)
7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE
IDENTIFIED WITH THE FOLLOWING OUTER FINISH:
POSITIVE CONDUCTORS = RED
NEGATIVE CONDUCTORS = BLACK
NEC 210.5(C)(2)
8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV
WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE
PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT
SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL
CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND
WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤
9 CURRENT CARRYING CONDUCTORS.
9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS
OTHERWISE NOTED
10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON
ROOFTOP AND SHALL BE LIMITED TO 12” IF USED
OUTDOORS
11.)OVERCURRENT PROTECTION FOR CONDUCTORS
CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE
LOCATED WITHIN 10' OF THE POINT OF CONNECTION NEC
690.9(A)(3)(2)
12.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A
UTILITY AND THE OTHER AN INVERTER, PV BACKFEED
BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY
NEC 705.12(B)(3)(2)
13.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY
GENERATION CIRCUITS AND NO UNUSED POSITIONS OR
LOADS
14.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE
A NEMA 3R RATING
NOTE:
INTERNAL REVENUE GRADE MONITORING
CONTAINED WITHIN SOLAR EDGE INVERTER
SOLAR EDGE PN. RWND-3D-240-MB
EG
INVERTER #1 - SE10000H-US000BEi4
DC AC
Imp 27 Pout 10000
Vmp 400 Imax 42
Voc 480 OCPDmin 52.5
Isc 30 Vnom 240
PV MODULE SPECIFICATIONS
HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405)
Imp 10.83
Vmp 37.39
Voc 45.34
Isc 11.17
A #6 THWN-2 GEC TO EXISTING GROUND ROD
B 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND
C 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND
D 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND
E 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND
F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY
G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2
NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR
TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS
INVERTER #1
PV+L1 L2 N PV-D
SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS
27 - 405W MODULES W/ 1 SOLAR EDGE S440 PER MODULE
15 ADC MAX PER STRING
1 STRING OF 13 MODULES IN SERIES - 400 Vmax
1 STRING OF 14 MODULES IN SERIES - 400 Vmax
*2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1
f 8"x8"
JUNCTION
BOX
LOCKABLE 60A DISCONNECT
FUSED W/ 60A FUSES
SQUARE D
PN: D222NRB
240V 1Ø
G
NEW PVC
TAP BOX
INSULATED LINE
TAPS TO BE
INSTALLED ON
MAIN FEEDERS
NEC 705.12(A)
EXISTING
MAIN BREAKER LOAD CENTERNEUTRAL2p200AMAIN240V1Ø
EXISTING
120/240V
UTILITY
METER
EXISTING
GENERATOR
M
NEUTRAL2P200A
G
EXISTING
MAIN BREAKER LOAD CENTER
EXISTING
GENERATOR TRANSFER SWITCH
200A MAIN BREAKER
200A BUSBAR
BONDED NEUTRAL
NEC 2023
P1 ISSUED TO TOWNSHIP FOR PERMIT 9/8/2023
NO.DESCRIPTION DATE
COHOLAN, RYAN-
TRINITY ACCT #: 2023-04-866176
260 CHURCH ST
WEST BARNSTABLE, MA 02668
41.695905619713415,-70.374082872
25381
PROPOSED PV SOLAR SYSTEM
DRAWING DATE:9/8/2023
DRAWN BY:HL
REVISED BY:
DC SYSTEM SIZE:10.935kW
AC SYSTEM SIZE:10kW
MODULE COUNT:27
MODULES USED:HANWHA 405
MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405
UTILITY COMPANY:EVERSOURCE
UTILITY ACCT #:14515650084
UTILITY METER #:2300458
DEAL TYPE:SUNNOVA
P1
R
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
JOB NAME:COHOLAN, RYAN-
ADDRESS:260 Church St
West Barnstable, MA 02668
41.695905619713415,-70.37408287225381
58.862 ESTIMATED PERSONNEL HOURS 2.45 DAYS 1.84 DAYS 1.23 DAYS
•27 HANWHA 405's (10.935KW)(CREW OF 3)(CREW OF 4)(CREW OF 6)
•2 SEPARATE ARRAYS
•16' PEAK TO GROUND
•27 PORTRAIT & 0 LANDSCAPED
•1 INVERTERS INSTALLED OUTSIDE
•NO TRENCH
ESTIMATED SENT TO JOB USED
□HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405)27 ______
□S440 SE OPTIMIZERS 27 ______
□SE10000H-US000BEi4 1 ______
□60A OUTDOOR FUSED DISCONNECT W/ (2) 60A FUSES 1 ______
□60A OUTDOOR NON-FUSED DISCONNECT 1 ______
□SOLADECK BOX(ES) & HAYCO CONNECTOR(S)2 ______
□PV LEAD WIRE 100'______
□INSULATED BUG BITES (LINE TAPS)2 ______
□ECOFASTEN 2012025 CF STD RAIL MLL AL 171.5 14 ______
□ECOFASTEN 2012013 CF RAIL SPLICE 11 ______
□ECOFASTEN 2099017 CF END CLAMP 32MM BLK 16 ______
□ECOFASTEN 2099022 CF MID CLAMP SHORT BLK 46 ______
□ECOFASTEN 4011011 MODULE JUMPER 2 ______
□GROUNDING LUG (NOT PROVIDED BY ECOFASTEN)2 ______
□ECOFASTEN 2012022 CF UNIV L-FOOT MLL 3 56 ______
□ECOFASTEN 3012020 GF-1 FLASHING GLV BLK 8 x 10 56 ______
□ECOFASTEN 2012019 CF MLPE MOUNT 27 ______
□ECOFASTEN 2012020 CF WIRE MGMT CLIP 27 ______
□ECOFASTEN 2012024 CF END CAP 16 ______
MATERIAL LIST
R(FOR INTERNAL USE ONLY)
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
INSTALLATION OF NEW
ROOF MOUNTED PV SOLAR SYSTEM
260 CHURCH ST
COHOLAN, RYAN-260 CHURCH ST
WEST BARNSTABLE, MA 02668
41.695905619713415,-70.374082872
25381
R
APPENDIX
CONTENTS
LABELS, STICKERS, AND PLACARDS
EQUIPMENT DATA SHEETS
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
WEST BARNSTABLE, MA 02668
153007
COHOLAN, RYAN D & KATIE J
260 CHURCH STREET
Property ID:
WEST BARNSTABLE, MA 02668
153007001
JONES, PRISCILLA A
240 CHURCH STREET
Property ID:
WEST BARNSTABLE, MA 02668
153008
FITTON, JEREMIAH
282 CHURCH STREET
Property ID:
WEST BARNSTABLE, MA 02668-1410
153012001
TANSEY, SUSAN E & JOHN R
263 CHURCH STREET
Property ID: