Loading...
HomeMy WebLinkAboutCOA 260 Church StreetNJ, Electrical Contractor business permit number 34EB01547400 NJ, HIC reg. # 13VH01244300 For other jurisdictions, please visit: http://www.trinity-solar.com/about-us/locations-and-licenses Corporate Headquarters 1-877-SUN-SAVES 2211 Allenwood Road Ph: 732-780-3779 Wall, New Jersey 07719 Fax: 732-780-6671 www.trinity-solar.com FOR INFORMATION ABOUT CONTRACTORS AND THE CONTRACTORS’ REGISTRATION ACT, CONTACT THE NEW JERSEY DEPARTMENT OF LAW AND PUBLIC SAFETY, DIVISION OF CONSUMERS AFFAIRS AT 1-888-656-6225. Date __________________________________ Print Name __________________________________ Customer Signature __________________________________ Name on Electric Utility Account: __________________ Electric Utility Account No.: ______________________ Electric Utility Company:________________________ given for my own convenience and benefit in order to expedite the approvals processes. solar transaction and are not a condition of the related solar agreement included herewith but are being and effect until revoked. I acknowledge that these authorizations are not required to proceed with the Approvals Paperwork when submitted. My authorizations memorialized herein shall remain in full force signatures to Approvals Paperwork for purposes of the foregoing. Trinity Solar will provide copies of herewith for my signature, in furtherance of the related solar transaction, and I am providing any certification documents (“Approvals Paperwork”), including those for which signature pages are included documentation to, date, submit, re-submit, revise, amend and modify application, submission and populate technical details, fill-in, edit, compile, attach drawings, plans, data sheets and other Without limitation to the generality of the foregoing I specifically authorize Trinity Solar et al. to permits on file for the purpose of updating/applying with an alternate subcontractor. This authorization includes the transfer/re-administering, and/or cancellation of any existing with any state and/or local solar incentive program. obtaining permission and approval for interconnection with the electric utility company, and registration Jurisdiction as required for the installation of a Photovoltaic System located on my property, applying and limited purpose of applying for and obtaining local building and other permits from the Authority Having subcontractors, including without limitation, _______________________, to act as my Agent for the I hereby authorize Trinity Heating & Air, Inc. DBA Trinity Solar and its employees, agents, and (print address) _____________________________________________. am the owner of the property located at address: (print name) I, _____________________________________, HOMEOWNERS AUTHORIZATION FORM CoholanKatie Eversource Katie Coholan Katie Coholan 260 Church St West Barnstable MA 8/28/23 2,000.00 This map is for illustration purposes only. It is not adequate for legal boundary determination or regulatory interpretation. This map does not represent an on-the-ground survey. It may be generalized, may not reflect current conditions, and may contain cartographic errors or omissions. Parcel lines shown on this map are only graphic representations of Assessor’s tax parcels. They are not true property boundaries and do not represent accurate relationships to physical objects on the map such as building locations. 3330167 Feet feetApprox. Scale: 1 inch =167 Legend Town of Barnstable GIS Unit 367 Main Street, Hyannis, MA 02601 508-862-4624 gis@town.barnstable.ma.us Map printed on:10/16/2023 Road Names INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 260 CHURCH ST WEST BARNSTABLE, MA 02668 41.695905619713415,-70.37408287225381 CHURCH ST P1 ISSUED TO TOWNSHIP FOR PERMIT 9/8/2023 NO.DESCRIPTION DATE COHOLAN, RYAN- TRINITY ACCT #: 2023-04-866176 260 CHURCH ST WEST BARNSTABLE, MA 02668 41.695905619713415,-70.374082872 25381 PROPOSED PV SOLAR SYSTEM DRAWING DATE:9/8/2023 DRAWN BY:HL REVISED BY: DC SYSTEM SIZE:10.935kW AC SYSTEM SIZE:10kW MODULE COUNT:27 MODULES USED:HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY:EVERSOURCE UTILITY ACCT #:14515650084 UTILITY METER #:2300458 DEAL TYPE:SUNNOVA P1 R 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ROOF 1 MODULES: 0 PITCH: 34° ORIENTATION: 32° ROOF 2 MODULES: 17 PITCH: 34 ORIENTATION: 212 ROOF 3 MODULES: 0 PITCH: 34° ORIENTATION: 119° ROOF 4 MODULES: 0 PITCH: 34° ORIENTATION: 302° ROOF 5 MODULES: 10 PITCH: 34 ORIENTATION: 212 ROOF 6 MODULES: 0 PITCH: 34° ORIENTATION: 299° ROOF 7 MODULES: 0 PITCH: 14° ORIENTATION: 32° ROOF 8 MODULES: 0 PITCH: 34° ORIENTATION: 122° ROOF 9 MODULES: 0 PITCH: 14° ORIENTATION: 299° ROOF 10 MODULES: 0 PITCH: 10° ORIENTATION: 32° ROOF 11 MODULES: 0 PITCH: 23° ORIENTATION: 321° ROOF 12 MODULES: 0 PITCH: 23° ORIENTATION: 141° N S270 90 13522545 315DC AC D TS epM 41.695905619713415,-70.37408287225381 27 HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405) 1 SE10000H-US000BEi4 INSIDE OUTSIDE. OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE. P1 ISSUED TO TOWNSHIP FOR PERMIT 9/8/2023 NO.DESCRIPTION DATE COHOLAN, RYAN- TRINITY ACCT #: 2023-04-866176 260 CHURCH ST WEST BARNSTABLE, MA 02668 41.695905619713415,-70.374082872 25381 PROPOSED PV SOLAR SYSTEM DRAWING DATE:9/8/2023 DRAWN BY:HL REVISED BY: DC SYSTEM SIZE:10.935kW AC SYSTEM SIZE:10kW MODULE COUNT:27 MODULES USED:HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY:EVERSOURCE UTILITY ACCT #:14515650084 UTILITY METER #:2300458 DEAL TYPE:SUNNOVA P1 NOTES: 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. M UD SP P DC AC ep D DC R 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SD TS CALCULATIONS FOR CURRENT CARRYING CONDUCTORS REQUIRED CONDUCTOR AMPACITY PER STRING [NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A AWG #10, DERATED AMPACITY AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96 RACEWAY DERATING = 4 CCC: 0.80 (40*.96)0.80 = 30.72A 30.72A >_ 18.75A, THEREFORE WIRE SIZE IS VALID TOTAL AC REQUIRED CONDUCTOR AMPACITY 42.00A*1.25 = 52.50A AWG #6, DERATED AMPACITY AMBIENT TEMP: 30°C, TEMP DERATING: 1.0 RACEWAY DERATING <_ 3 CCC: N/A 75A*1.0 = 75A 75A >_ 52.50A, THEREFORE AC WIRE SIZE IS VALID CALCULATION FOR PV OVERCURRENT PROTECTION TOTAL INVERTER CURRENT: 42.00A 42.00A*1.25 = 52.50A --> 60A OVERCURRENT PROTECTION IS VALID ARRAY CIRCUIT WIRING NOTES 1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2020 2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP = -16°C 3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP = 33°C 4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) 5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A) THROUGH (D) 6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41 (A)(4) 7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: POSITIVE CONDUCTORS = RED NEGATIVE CONDUCTORS = BLACK NEC 210.5(C)(2) 8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤ 9 CURRENT CARRYING CONDUCTORS. 9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS OTHERWISE NOTED 10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12” IF USED OUTDOORS 11.)OVERCURRENT PROTECTION FOR CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE LOCATED WITHIN 10' OF THE POINT OF CONNECTION NEC 690.9(A)(3)(2) 12.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A UTILITY AND THE OTHER AN INVERTER, PV BACKFEED BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY NEC 705.12(B)(3)(2) 13.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED POSITIONS OR LOADS 14.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3R RATING NOTE: INTERNAL REVENUE GRADE MONITORING CONTAINED WITHIN SOLAR EDGE INVERTER SOLAR EDGE PN. RWND-3D-240-MB EG INVERTER #1 - SE10000H-US000BEi4 DC AC Imp 27 Pout 10000 Vmp 400 Imax 42 Voc 480 OCPDmin 52.5 Isc 30 Vnom 240 PV MODULE SPECIFICATIONS HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405) Imp 10.83 Vmp 37.39 Voc 45.34 Isc 11.17 A #6 THWN-2 GEC TO EXISTING GROUND ROD B 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND C 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND D 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND E 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2 NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS INVERTER #1 PV+L1 L2 N PV-D SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 27 - 405W MODULES W/ 1 SOLAR EDGE S440 PER MODULE 15 ADC MAX PER STRING 1 STRING OF 13 MODULES IN SERIES - 400 Vmax 1 STRING OF 14 MODULES IN SERIES - 400 Vmax *2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 f 8"x8" JUNCTION BOX LOCKABLE 60A DISCONNECT FUSED W/ 60A FUSES SQUARE D PN: D222NRB 240V 1Ø G NEW PVC TAP BOX INSULATED LINE TAPS TO BE INSTALLED ON MAIN FEEDERS NEC 705.12(A) EXISTING MAIN BREAKER LOAD CENTERNEUTRAL2p200AMAIN240V1Ø EXISTING 120/240V UTILITY METER EXISTING GENERATOR M NEUTRAL2P200A G EXISTING MAIN BREAKER LOAD CENTER EXISTING GENERATOR TRANSFER SWITCH 200A MAIN BREAKER 200A BUSBAR BONDED NEUTRAL NEC 2023 P1 ISSUED TO TOWNSHIP FOR PERMIT 9/8/2023 NO.DESCRIPTION DATE COHOLAN, RYAN- TRINITY ACCT #: 2023-04-866176 260 CHURCH ST WEST BARNSTABLE, MA 02668 41.695905619713415,-70.374082872 25381 PROPOSED PV SOLAR SYSTEM DRAWING DATE:9/8/2023 DRAWN BY:HL REVISED BY: DC SYSTEM SIZE:10.935kW AC SYSTEM SIZE:10kW MODULE COUNT:27 MODULES USED:HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY:EVERSOURCE UTILITY ACCT #:14515650084 UTILITY METER #:2300458 DEAL TYPE:SUNNOVA P1 R 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com JOB NAME:COHOLAN, RYAN- ADDRESS:260 Church St West Barnstable, MA 02668 41.695905619713415,-70.37408287225381 58.862 ESTIMATED PERSONNEL HOURS 2.45 DAYS 1.84 DAYS 1.23 DAYS •27 HANWHA 405's (10.935KW)(CREW OF 3)(CREW OF 4)(CREW OF 6) •2 SEPARATE ARRAYS •16' PEAK TO GROUND •27 PORTRAIT & 0 LANDSCAPED •1 INVERTERS INSTALLED OUTSIDE •NO TRENCH ESTIMATED SENT TO JOB USED □HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405)27 ______ □S440 SE OPTIMIZERS 27 ______ □SE10000H-US000BEi4 1 ______ □60A OUTDOOR FUSED DISCONNECT W/ (2) 60A FUSES 1 ______ □60A OUTDOOR NON-FUSED DISCONNECT 1 ______ □SOLADECK BOX(ES) & HAYCO CONNECTOR(S)2 ______ □PV LEAD WIRE 100'______ □INSULATED BUG BITES (LINE TAPS)2 ______ □ECOFASTEN 2012025 CF STD RAIL MLL AL 171.5 14 ______ □ECOFASTEN 2012013 CF RAIL SPLICE 11 ______ □ECOFASTEN 2099017 CF END CLAMP 32MM BLK 16 ______ □ECOFASTEN 2099022 CF MID CLAMP SHORT BLK 46 ______ □ECOFASTEN 4011011 MODULE JUMPER 2 ______ □GROUNDING LUG (NOT PROVIDED BY ECOFASTEN)2 ______ □ECOFASTEN 2012022 CF UNIV L-FOOT MLL 3 56 ______ □ECOFASTEN 3012020 GF-1 FLASHING GLV BLK 8 x 10 56 ______ □ECOFASTEN 2012019 CF MLPE MOUNT 27 ______ □ECOFASTEN 2012020 CF WIRE MGMT CLIP 27 ______ □ECOFASTEN 2012024 CF END CAP 16 ______ MATERIAL LIST R(FOR INTERNAL USE ONLY) 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 260 CHURCH ST COHOLAN, RYAN-260 CHURCH ST WEST BARNSTABLE, MA 02668 41.695905619713415,-70.374082872 25381 R APPENDIX CONTENTS LABELS, STICKERS, AND PLACARDS EQUIPMENT DATA SHEETS 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com WEST BARNSTABLE, MA 02668 153007 COHOLAN, RYAN D & KATIE J 260 CHURCH STREET Property ID: WEST BARNSTABLE, MA 02668 153007001 JONES, PRISCILLA A 240 CHURCH STREET Property ID: WEST BARNSTABLE, MA 02668 153008 FITTON, JEREMIAH 282 CHURCH STREET Property ID: WEST BARNSTABLE, MA 02668-1410 153012001 TANSEY, SUSAN E & JOHN R 263 CHURCH STREET Property ID: