Loading...
HomeMy WebLinkAboutUpdated Plans 2071 Main StreetTHIS PROJECT COMPLIES WITH THE FOLLOWING:2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL MECHANICAL CODE2018 INTERNATIONAL PLUMBING CODE2018 INTERNATIONAL FUEL GAS CODE2018 INTERNATIONAL ENERGY CONSERVATION CODE2015 INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL SWIMMING POOL AND SPA CODE2020 NATIONAL ELECTRICAL CODEAS ADOPTED BY TOWN OF BARNSTABLECODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:ROOF MOUNT PHOTOVOLTAIC SYSTEMPV-1PROJECT DETAILSPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BARRAY DETAILSPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8MICROINVERTER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2020 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.PV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-GREG ALBRIGHTSITE LOCATIONPROJECT DETAILSSigned by: J. Rogelstad, PE Signed on: 04/03/2024 218'-6"287'-8"305'-11"244'-5"59'-4"95'-7"139'-10"39'-9"UMMSPACSUB(E) MAIN SERVICE PANEL(N) COMBINER BOX(N)EATON DG222NRB (OREQUIVALENT) AC DISCONNECT(E) UTILITY METER(E) SUB PANELPROPERTY LINE(N) 26 JINKO SOLAR:JKM385M-6RL3-BROOF LINEFIRE ACCESS PATHWAYSCPSITE PLANSCALE: 1/32" = 1'-0"1PV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-ROOF AREA: 4505.18 SQ FTSITE PLANLEGEND:CHIMNEYPIPE VENTATTACHMENTSMODULESRAFTERSRAILSETBACKMSP AC ACDISCONNECTMSPJUNCTIONBOXPRODUCTIONMETERDC / ACMICROINVERTER PM JB CPCOMBINERPANELGREG ALBRIGHT"AC DISCONNECT SHALL BE 24/7 ACCESSIBLE, WITHIN 10 FEET OF, WITHIN VISIBLESIGHT OF, AND ON SAME WALL AS THE UTILITY METER (EXCEPTION FOR PEDESTALMETERS)"MAIN STREETDRIVEWAY12Signed by: J. Rogelstad, PE Signed on: 04/03/2024 MSPACSUB(E) MAIN SERVICE PANEL(N) COMBINER BOX(N)EATON DG222NRB(OR EQUIVALENT) ACDISCONNECT(E) SUB PANEL(N) 26 JINKO SOLAR:JKM385M-6RL3-BCPPV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-ROOF PLANSCALE: 2/25" = 1'-0"1NOTES:1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA: 4505.18 SQ FTROOF PLAN WITH MODULES LAYOUTLEGEND:CHIMNEYPIPE VENTATTACHMENTSMODULESRAFTERSRAILSETBACKMSP AC ACDISCONNECTMSPJUNCTIONBOXPRODUCTIONMETERDC / ACMICROINVERTER PM JB CPCOMBINERPANELTOTAL ROOF AREA: 4505.18 SQ FTTOTAL ARRAY AREA: 534.20 SQ FTARRAY COVERAGE: 11.86%SYSTEM DISTRIBUTED WEIGHT: 2.29 LBSROCKIT SMART SLIDE POINT-LOAD: 11.31LBSGREG ALBRIGHT3'-0"3'-0"3'-0"3'-0"FIRE ACCESSPATHWAYSFIRE ACCESSPATHWAYS3'-0" 3'-0" 3'-0"3'-0"3'-0"3'-0"3'-0"12Signed by: J. Rogelstad, PE Signed on: 04/03/2024 PV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-ARRAY DETAILSROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCHARRAY PITCHAZIMUTHROOF AREAARRAY AREAROOF 163434182.92226.15 SQ FT123.28 SQ FTROOF 2153434182.92625.44 SQ FT308.19 SQ FTROOF 353433.7182.92225.49 SQ FT102.73 SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FTROOF DETAILS:TOTAL ROOF AREA: 4505.18 SQ FTTOTAL ARRAY AREA: 534.20 SQFTARRAY COVERAGE: 11.86%SYSTEM DISTRIBUTED WEIGHT: 2.29 LBSROCKIT SMART SLIDE POINT-LOAD: 11.31 LBSGREG ALBRIGHT12Signed by: J. Rogelstad, PE Signed on: 04/03/2024 ROCKIT MOUNTROOF SURFACESKIRTROCKIT MOUNTROOFMEMBRANEPV MODULEROCKIT MOUNTROOFMEMBRANE2" MIN. EMBED.2" MIN. EMBED.2 x #12 WOODSCREW WITH 2"MIN. EMBEDMENTAND FLAT WASHER2 x #12 WOODSCREW WITH 2"MIN. EMBEDMENTAND FLAT WASHER2" MIN. EMBED.PV MODULEPV MODULE3" MIN.(E)RAFTER/TOP-CHORD2 x #12 WOODSCREW WITH 2"MIN. EMBEDMENTAND FLAT WASHER6" MAX.TABLE 1 - ARRAY INSTALLATIONROOFPITCHROOFING TYPEATTACHMENT TYPEFRAMING TYPEMAX UNBRACEDLENGTH(FT.)STRUCTURALANALYSIS RESULTPENETRATIONPATTERNMAXATTACHMENTSPACING (IN.)MAX RAILOVERHANG(IN.)ROOF 134Comp ShingleEcofasten RockIt Smart Slide2x10 @ 16" O.C.16.75PASSSTAGGERED4816ROOF 234Comp ShingleEcofasten RockIt Smart Slide2x10 @ 16" O.C.16.75PASSSTAGGERED4816ROOF 333.7Comp ShingleEcofasten RockIt Smart Slide2x10 @ 16" O.C.16.75PASSSTAGGERED48161. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY.2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS.3. MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS.ATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-MOUNTING DETAILSSTAGGERED DETAILFor Illustration purposes onlySTACKED DETAILFor Illustration purposes onlyGREG ALBRIGHTSigned by: J. Rogelstad, PE Signed on: 04/03/2024 4 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" EMT CONDUITJUNCTIONBOXNEMA 3RINVSTRING-213 JINKO SOLAR: JKM385M-6RL3-BBRANCH CABLES INTEGRAL TOINVERTERS 1 #6 AWG, BARECOPPER GROUNDENPHASE IQ8PLUS-72-2-USMICROINVERTERSINVSTRING-113 JINKO SOLAR: JKM385M-6RL3-BENPHASE IQ8PLUS-72-2-USMICROINVERTERSBRANCH CABLES INTEGRAL TO INVERTERS1 #6 AWG, BARE COPPER GROUNDUM(E) 200A / 2PMAIN BREAKER(TOP FED)(E) 200A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITY METER(N) LINESIDE TAP VIA ULLISTED CONNECTORTO UTILITYUNDERGROUNDFEED3 - #8 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 60A FUSEDAC DISCONNECTEATON DG222NRB (OREQUIVALENT)WITH 40A FUSES,KNIFEBLADE, LOCKABLE, NEMA3R, UL LISTED3 - #6 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUIT(N) ENPHASECOMBINER BOX(N) 20A / 2P(N) 20A / 2P(N) 15A / 2PIQ GATEWAYM2-PAIR #18 AWG STRANDEDNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED FUSE SIZINGMAX. CONTINUOUS OUTPUT 31.46A @ 240V31.46X1.25=39AMPS40A FUSES - OKPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-THREE LINE DIAGRAMGREG ALBRIGHT PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DCMODULETOMICROINVERTER2104014.030.96138.4017.532ACMICROINVERTERTOJUNCTION BOX2104015.730.96138.4019.663ACJUNCTION BOXTOENPHASE COMBINER PANEL4104015.730.960.830.7219.664ACENPHASE COMBINER PANELTOAC DISCONNECT385531.460.96152.8039.335ACAC DISCONNECTTOPOI367531.460.96172.0039.33--------------------------------------------------------------------------------CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-QTY.PARTPART #DESCRIPTION26110 - MODULESPV-118-385-2"MFG: JINKO, 385W MONO BOB, MFG SKU: JKM385M-6RL3-B"26120 - INVERTERSINV-120-015"MFG: ENPHASE, IQ8+ MICROINVERTER 72CELL MC4, MFG SKU: IQ8PLUS-72-2-US"30160 - EQUIPMENT ACCESSORIESEA-160-106"MFG: ENPHASE, Q CABLE PORTRAIT FOR 60/72 CELL, MFG SKU: Q-12-10-240"30160 - EQUIPMENT ACCESSORIESEA-160-105"MFG: ENPHASE, Q CABLE LANDSCAPE 60 CELL, MFG SKU: Q-12-17-240"6.5160 - EQUIPMENT ACCESSORIESEA-160-107"MFG: ENPHASE, SEALING CAP FOR Q CABLE, MFG SKU: Q-SEAL-10"3160 - EQUIPMENT ACCESSORIESEA-160-109"MFG: ENPHASE, TERMINATOR CAP FOR Q CABLE, MFG SKU: Q-TERM-10"1160 - EQUIPMENT ACCESSORIESEA-160-111"MFG: ENPHASE, FEMALE FIELD WIREABLE CONNECTOR FOR Q CABLE, MFG SKU: Q-CONN-10F"1160 - EQUIPMENT ACCESSORIESEA-160-112"MFG: ENPHASE, MALE FIELD WIREABLE CONNECTOR FOR Q CABLE, MFG SKU: Q-CONN-10M"1260 - FITTINGS/ANCHORSRAC-261-527"MFG: UNIRAC, JUNCTION BOX, COMP SHINGLE AND RAIL MOUNT APPLICATIONS, MFG SKU: SOLOBOX-D"1210 - RAILSRAC-211-201"MFG: UNIRAC, E-BOSS J-BOX MOUNTING BRACKET, MFG SKU: 00802JB"1320 - DISCONNECTSEE-321-061"MFG: EATON, DISCONNECT, GENERAL DUTY, 2P, 240V, 60A, FUSIBLE W/ NEUTRAL, NEMA 3R, MFG SKU: DG222NRB"4350 - ELECTRICAL ACCESSORIESEA-350-326"MFG: STAUBLI MULTI-CONTACT, MC4 CONNECTORS (FEMALE), MFG SKU: PV-KBT4/6I-UR"4350 - ELECTRICAL ACCESSORIESEA-350-327"MFG: STAUBLI MULTI-CONTACT, MC4 CONNECTORS (MALE), MFG SKU: PV-KST4/6I-UR"260260 - FITTINGS/ANCHORSRAC-260-550"MFG: BURNDY, PV WILEY CABLE CLIP THICKNESS RANGE: 1.3 TO 3MM MFG SKU: ACC-FPV180"108260 - FITTINGS/ANCHORSRAC-265-034"MFG: ECO FASTEN, ROCKIT SMART SLIDE BLK 6 - 75"", MFG SKU: 2011024"20260 - FITTINGS/ANCHORSRAC-261-602"MFG: UNIRAC, SFM 2"" MICRORAIL, MFG SKU: 250020U"108260 - FITTINGS/ANCHORSRAC-265-004"MFG: ECO FASTEN, ROCKIT COMP COUPLING AL BLK, MFG SKU: 2011021"1260 - FITTINGS/ANCHORSRAC-265-028"MFG: ECO FASTEN, SKIRT AL BLK 35MM & 40MM A80, MFG SKU: 2099012"1260 - FITTINGS/ANCHORSRAC-265-031"MFG: ECO FASTEN, SKIRT END CAP PLS 35MM&40MM-A, MFG SKU: 2099035"26260 - FITTINGS/ANCHORSRAC-265-018"MFG: ECO FASTEN, FRAME MLPE MOUNT SS, MFG SKU: 4011012"1260 - FITTINGS/ANCHORSRAC-260-049"MFG: EZ SOLAR, JUNCTION BOX, PV, MFG SKU: JB-1.2"1260 - FITTINGS/ANCHORSRAC-263-101"MFG: SNAP N RACK, WIRE SAVER, TOP AND BOTTOM, MFG SKU: 242-92262"108260 - FITTINGS/ANCHORSRAC-265-034"MFG: ECO FASTEN, ROCKIT SMART SLIDE BLK 6 - 75"", MFG SKU: 2011024"432260 - FITTINGS/ANCHORSRAC-265-035"MFG: ECO FASTEN, ROCKIT SCREW #12X3"" W/BW, MFG SKU: 2011025"1350 - ELECTRICAL ACCESSORIESEA-350-585"MFG: ILSCO, GROUND LUG, MFG SKU: SGB-4"108260 - FITTINGS/ANCHORSRAC-265-003"MFG: ECO FASTEN, ROCKIT MOUNT AL BLK, MFG SKU: 2011020"1220 - MIDS AND ENDSRAC-223-301"MFG: SNAP N RACK, TDS, SPEEDSEAL CONDUIT MOUNT KIT, MFG SKU: 242-05164"OCPD SIZES:20A BREAKER20A BREAKER40A BREAKERSERVICE LIST:NONEEQUIPMENT & SERVICE LISTGREG ALBRIGHT NOTES:M690.13(B)MAIN PHOTOVOLTAICSYSTEM DISCONNECTTURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAYIFC 605.11.3.1(1) & 690.56(C)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC NEC 690.13(B)INVERTERDCSOLAR PV DC CIRCUITEVERY 10' ON CONDUIT AND ENCLOSURESSOLAR ELECTRICPV PANELS706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANEL!WARNINGSINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUITSNEC 710.15(C) & 692.9 (C)NEC 690.15 (B) & NEC 690.33(D)(2)DO NOT DISCONNECTUNDER LOADNEC 705.12(D) & NEC 690.59!CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 705.12(D) & NEC 690.59NEC 705.12(C) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.!WARNINGARC FLASH AND SHOCK HAZARDAPPROPRIATE PPE REQUIRED24 INCH3480 VAC42 INCH12 INCH1 INCHFLASH HAZARD BOUNDARYCAL/CM^2 FLASH HAZARD AT 18 INCHESSHOCK HAZARD WHEN COVER IS REMOVEDLIMITED APPROACHRESTRICTED APPROACH - 500 V CLASS 00 GLOVESPROHIBITED APPROACH - 500 V CLASS 00 GLOVESLOCATION:2071 MAIN STREET,BARNSTABLE, MA 02668PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC AC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:31.46A240V!WARNINGTHIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEED AMPACITY OF BUSBARNEC 690.54NEC 705.12(B)(3)(3)NEC 706.15(C) AND NEC 110.16PM NEC 705.12(D) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTNEC 690.31(E)PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESNEC 690.31NEC 690.31(D)(2) NEC 690.13(B)PHOTOVOLTAICDC DISCONNECT706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHT NEC 690.53MAXIMUM DC VOLTAGEOF PV SYSTEMARRAYJ/BNEC 690.31(G)(3) & (4)706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)MAXIMUM VOLTAGEMAXIMUM CIRCUIT CURRENTMAX DC-DC CONVERTEROUTPUT CURRENTVAAN/A6015PV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-LABELSGREG ALBRIGHT1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.ARIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS CAUTION:PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNSUBPANELMAIN SERVICE PANELAC DISCONNECTCOMBINER PANEL26 PV MODULES MSPACSUBCPPV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-ENPHASE MICROINVERTER CHARTMICROINVERTER CHARTGREG ALBRIGHT11-2021-4041-60234567891011121314151617181920 MSPACSUBCPPV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-SAFETY PLANGREG ALBRIGHTSAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THEPRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ONTHE JHA SHEETINCIDENT REPORTING:INJURIES - CALL INJURY HOTLINE(855) 400-7233*If injury is life threatening, call 911 first THEN the Injury HotlineNON-INJURIES - USE MOBILE INCIDENT REPORTING(Auto, Property Damage, Near Miss)NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC:NAME: _______________________________________________ADDRESS: ___________________________________________NEAREST HOSPITAL:NAME:_______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATION:NAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN ANDSIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THEPLAN FOR WORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OBREAK AND WATER LOGTHIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS ISCOMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREESNAME0800HRS0900HRS1000HRS1100HRS1200HRS1300HRS1400HRS1500HRS1600HRSPOLICIESINSTRUCTIONS:1.SCAN QR LINK BELOW TOACCESS ALL FREEDOMFOREVER SAFETYPOLICIES AND PROGRAMS. JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:405456DESIGNED BY:C.H.CLIENT:MARY ANNE FENNEY2071 MAIN STREET, BARNSTABLE, MA 02668AHJ: TOWN OF BARNSTABLEUTILITY: EVERSOURCE ENERGYMETER: 44 001 125APN: BARN-000216-000000-000075-000001PHONE: +1 508 367 4375EMAIL: CCIMMA@AOL.COMSYSTEM:SYSTEM SIZE (DC): 26 X 385 = 10.010 kWSYSTEM SIZE (AC): 7.540 kW @ 240VMODULES: 26 X JINKO SOLAR:JKM385M-6RL3-BMICROINVERTERS: 26 X ENPHASEIQ8PLUS-72-2-USDATE:4/3/2024P.O.3/15/20244/3/20242--1C.H.-SAFETY PLANGREG ALBRIGHT SCAN QR CODE TO ACCESS REFERENCE LINKPV INSTALLATION REFERENCESFREEDOM REFERENCESBATTERY INSTALLATION REFERENCESENPHASESOLAREDGE TESLAINSTALL HOTLINETESLA Storage SystemsNON‐BACKUP Battery SystemsSOLAREDGE Storage SystemsEnphase Storage SystemsMisc. Quick GuideFOR INSTALLATION REFERENCE ONLYV1.4 DATA SHEETIQ8 and IQ8+ MicroinvertersOur newest IQ8 Microinverters are the industry’s first microgrid-forming, software defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems.Easy to install• Lightweight and compact with plug-n-play connectors• Power Line Communication (PLC) between components• Faster installation with simple two-wire cablingHigh productivity and reliability• Produce power even when the grid is down*• More than one million cumulative hours of testing• Class II double-insulated enclosure• Optimized for the latest high-powered PV modulesMicrogrid-forming• Complies with the latest advanced grid support**• Remote automatic updates for the latest grid requirements• Configurable to support a wide range of grid profiles• Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 3rd Ed.) Note:IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, etc) in the same system.© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change.*Only when installed with IQ System Controller 2, meets UL 1741. **IQ8 and IQ8Plus support split-phase, 240V installations only.Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software.IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years.Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors.IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer’s instructions.IQ8SP-12A-DS-0067-03-EN-US-2022-12-27(1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.IQ8 and IQ8+ MicroinvertersINPUT DATA (DC) IQ8-60-2-USIQ8PLUS-72-2-USCommonly used module pairings1W235 – 350 235 – 440Module compatibility 60-cell / 120 half-cell54-cell / 108 half-cell, 60-cell / 120 half-cell, 66-cell / 132 half-cell and 72-cell / 144 half-cellMPPT voltage rangeV27 – 37 27 – 45Operating rangeV16 – 48 16 – 58Min. / Max. start voltageV22 / 48 22 / 58Max. input DC voltageV50 60Max. continuous input DC currentA10 12Max. input DC short-circuit currentA25Max. module IscA20Overvoltage class DC portIIDC port backfeed currentmA0PV array configuration 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ8-60-2-USIQ8PLUS-72-2-USPeak output powerVA245 300Max. continuous output powerVA240 290Nominal (L-L) voltage / range2V240 / 211 – 264Max. continuous output currentA1.0 1.21Nominal frequencyHz60Extended frequency rangeHz47 – 68AC short circuit fault current over 3 cycles Arms2Max. units per 20 A (L-L) branch circuit316 13Total harmonic distortion<5%Overvoltage class AC portIIIAC port backfeed currentmA30Power factor setting1.0Grid-tied power factor (adjustable) 0.85 leading – 0.85 laggingPeak efficiency%97.7CEC weighted efficiency%97Night-time power consumptionmW60MECHANICAL DATAAmbient temperature range -40°C to +60°C (-40°F to +140°F)Relative humidity range4% to 100% (condensing)DC Connector typeMC4Dimensions (H x W x D) 212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”)Weight1.08 kg (2.38 lbs)CoolingNatural convection – no fansApproved for wet locationsYesPollution degreePD3Enclosure Class II double-insulated, corrosion resistant polymeric enclosureEnviron. category / UV exposure rating NEMA Type 6 / outdoorCOMPLIANCECertificationsCA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB 3rd Ed.), FCC Part 15 Class B, ICES-0003 Class B, CAN / CSA-C22.2 NO. 107.1-01This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions.IQ8SP-12A-DS-0067-03-EN-US-2022-12-27 Product specificationsEaton DG222NRBCatalog Number: DG222NRBEaton General duty cartridge fuse safety switch, 60 A, NEMA 3R, Paintedgalvanized steel, Class H fuses, Fusible with neutral, Two-pole, Three-wire,Category: general duty safety switch, 240 VGeneral specificationsEaton general duty cartridge fuse safetyswitchDG222NRB7821131442217.35 in 14.37 in8.4 in 10 lbEaton Selling Policy 25-000, one (1) yearfrom the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.UL ListedMaximum hp ratings apply only whendual element fuses are used. 3-Phase hprating shown is a grounded B phaserating, UL listed.Product Name Catalog NumberUPCProduct Length/Depth Product HeightProduct Width Product WeightWarranty CertificationsCatalog NotesEaton Corporation plcEaton House30 Pembroke RoadDublin 4, IrelandEaton.com© 2023 Eaton. All RightsReserved.Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners.Eaton.com/socialmediaPhysical AttributesNEMA 3RPainted galvanized steelFusible with neutralTwo-pole3General duty, cartridge fusedPerformance Ratings60AClass H fuses240VMiscellaneousGeneral duty safety switchResourcesEaton's Volume 2—Commercial DistributionDouble Up on SafetySwitching Devices Flex CenterEaton Specification Sheet - DG222NRBEnclosureEnclosure materialFuse configurationNumber Of PolesNumber of wiresTypeAmperage RatingFuse class provisionVoltage ratingProduct CategoryCatalogsMultimediaSpecifications and datasheets ;5,60$576/,'(%/. 52&.,7)/$6+/(666/,'($66(0%/<$'+(6,9(5(/($6(/,1(5,7(012'(6&5,37,2152&.,760$576/,'($66(0%/<3$57180%(5'(6&5,37,215,60$576/,'(%/.0$7(5,$/$/80,180(3'0$'+(6,9(75($7('3$3(5),1,6+%/$&.5HY&61.317.82.8772.83.0076.2.5514.0.4210.5RI SMART SCREW #12X3" W/BWPART NUMBERDESCRIPTION2011025RI SMART SCREW #12X3" W/BWITEM NO.DESCRIPTION1SELF TAPPING SCREW #12 WITH SEALING WASHER ASSEMBLYMATERIALSTAINLESS STEEL, EPDM RUBBERFINISHMILL, BLACKRev: CS-2