HomeMy WebLinkAbout0038 COACH LANE - Health Mmsta' ble' ,` \ • • Commonwealth of Massachusetts _ Title 5 Official Inspection Form Ma Subsurface Sewage Disposal System Form Not for Voluntary Assessments S 23 I �M 38 Coach Lane � t Property Address Thomas J. Mullen - Owner Owner's Name information is required for every Barnstable MA 02630 May 13, 2017 page. Cityrrown State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important;when filling out forms A. General Information on the computer, use only the tab 1. Inspector: key to move your cursor-do not David D. Flaherty Jr., IRS, REHS use the return Name of Inspector key. Flaherty Environmental Services Company Name P.O. Box 81 Company Address Yarmouth Port MA 02675 CitylTown State Zip Code 774-994-1166 SI#4713 Telephone Number License Number B. Certification I certify that I have personally inspected the sewage'disposal system at this address and that the information reported below is true, accurate and complete as of the time of the inspection.The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5 (310 CMR 15.000).-The system: ® Passes ❑ Conditionally Passes ❑ Fails ❑ Needs urther Evaluation by the Local Approving Authority 7 � jMay 14, 2017 Insp o ignature Date 'The system inspector shall su mit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater,'the inspector and the.system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. ****This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. t5ins.doc-rev.6/16 "Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 1 of 17 Commonwealth of Massachusetts _ / Title 5 Official Inspection Form to Subsurface Sewage Disposal System Form Not for Voluntary Assessments a' 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017 required for every Y page. City/Town State Zip Code Date of Inspection B. Certification (cons.) Inspection Summary: Check A,B,C,D or E/always complete all of Section D A) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: Please disregard previous as builts due to addition B) System Conditionally Passes: ❑ -One or more system components as described in the "Conditional Pass" section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board.of Health, will pass.. Check the box for"yes", "no"or"not determined" (Y, N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over.20 years old* or the septic tank (whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than.20 years old is available. ❑ Y ❑ `N ❑ ND (Explain below): t5ins.doc•rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 17 Commonwealth of Massachusetts - _ Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments M 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 - May 13, 2017 required for every Y page. CirylTown State Zip Code Date of Inspection B. Certification (cont.) ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. B) System Conditionally Passes (cont.): ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below). ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): C) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of-Health in order to determine if the system is failing to protect public health, safety.or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR '15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety,and-the environment: ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh t5ins.doc•rev.6116 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments wM 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017 required for every Y page. City,rrown State Zip Code Date of Inspection` B. Certification (cont.) 2. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS)-and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system_ has a septic tank and SAS and the SAS is within aZone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well". Method used to determine distance: **This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: D) System Failure Criteria Applicable.to All Systems: You must indicate "Yes" or"No"to each of the following for all inspections: Yes No ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than 1/z day flow t5ins.doc r rev.6116 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 4 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments wM 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017 required for every" Y page. City/Town State Zip Code Date of Inspection B. Certification (cont.) Yes No ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ N Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well. ❑ 0 Any portion of a cesspool or privy is within 50 feet-of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis and chain of custody must be attached to this form.] ® The system is a cesspool serving a facility with a design flow of 2000gpd- 10,000g pd. ❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E) Large Systems: 'To be considered a large system the system must serve a facility with a design flow of 10,000,gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no" to each of the following, in addition to the questions in Section D. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ -❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area—IWPA)or a mapped Zone II of a public water supply well If you have answered"yes"to any question in Section E the system is considered a significant threat, or answered "yes" in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15:304. The system owner should contact the appropriate regional office of the Department. t5ins.doc•rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 17 Commonwealth of Massachusetts - Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017. required for every Y page. City/Town State Zip Code Date of Inspection C. Checklist Check if the following have been done. You must indicate"yes" or"no" as to each of the following: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ❑ ® Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined? (if they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was,the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ® ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ® ElDetermined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] D. System Information Residential Flow Conditions: Number of bedrooms(design): 3 Number of.bedrooms (actual): 3 DESIGN'flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330 t5ins.doc-rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage'Disposal System-Page 6 of 17 Commonwealth of Massachusetts - W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 ' May 13, 2017 required for every Y page. City/Town State Zip.Code Date of Inspection D. System Information Description: Number of current residents: 0 Does residence"have a garbage grinder? ❑ Yes ® No Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No information in this report.) p ) Laundry system inspected? ❑ Yes ❑ No Seasonal use? ❑ Yes ® No Water meter readings, if available last 2 ears usa e d 16: 71 gpd; '15: 9 ( Y 9 (gpd)): 192 gpd Detail: Sump pump? ❑ Yes ® No 2017 Last date of occupancy: Date Commercial/Industrial Flow Conditions: Type.of Establishment: Design flow(based on 310 CMR 15.203): gallons per day(gpd) Basis of design flow(seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ❑ No Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: t5ins.doc•rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017 required for every y page. City:/Town State Zip Code Date of Inspection D. System Information (cont.) Last date of occupancy/use: Date Other(describe.below): General Information Pumping Records: Source of information: BOH, not in past 5 years Was system pumped as part of the inspection? ❑ Yes Z No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from.system owner) and a copy of latest 'inspection of the I/A system by system operator under contract . ❑ Tight tank. Attach a copy of the.DEP approval. ❑ Other(describe): t5ins.doc•rev.6/16 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System•Page 8 of 17 Commonwealth of Massachusetts _ Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M •'' 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017 required for every y page. City,"rown State Zip Code Date of Inspection. D. System Information (coot.) Approximate age of all components, date installed (if known) and source of information: 1973 per BBOH Were sewage odors detected when arriving at the site? ❑ Yes ® No Building Sewer(locate on site plan): 2.5 Depth below grade: feet Material of construction: ®.cast iron ® 40 PVC ❑ other(explain): >50 Distance from private water supply well or suction line: feet Comments (on condition of joints, venting, evidence of leakage, etc.): points tight, venting through dwelling adequate,,no evidence of leakage Septic Tank(locate on site plan): Depth below grade: 1.5 feet Material of construction: ® concrete ❑ metal ❑fiberglass ❑`polyethylene ❑ other(explain) -If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No Dimensions: 1000 gallon 3" Sludge depth: t5ins.doc-rev.6/16 .Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 9 of 17 _ Commonwealth of Massachusetts _ Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments wM •'' 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017 required for every y page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Septic Tank(cont.) Distance from top of sludge to bottom of outlet tee or baffle 31" Scum thickness Distance from top of scum to top of outlet tee or baffle 7" Distance from bottom of scum to bottom of outlet tee or baffle 14„ How were dimensions determined? dip stick, tape measure Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): maintenance pumping recommended every two to three years, inlet&outlet concrete tees intact, liquid level appropriate, tank seems structurally sound, no evidence of leakage Grease Trap (locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date t5ins.doc•rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 10 of 17 Commonwealth of Massachusetts Title 5 official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 38 Coach Lane M Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA, 02630 May 13, 2017 required for-every _-Y page. CityfTown State Zip Code Date of Inspection D. System Information (cont.) Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day Alarm present: ❑ Yes ❑ No Alarm level: Alarm in working order: ❑ Yes ❑ No (Date of last pumping: Date Comments (condition of alarm and float switches, etc.): *Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No t5ins.doc•rev.6116 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 11 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments �M 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is required for every Barnstable MA 02630 May 13, 2017 page. City/town State Zip Code Date of Inspection D. System Information (cont.) Distribution Box (if present must be opened) (locate on site plan): Depth of liquid level above outlet invert n/.a Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): no dbox present Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No* . Alarms in working order: ❑ Yes ❑ No* Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): * If pumps or alarms are not in working order, system is a conditional pass. -Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: t5ins.doc-rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 17 Commonwealth of Massachusetts _ Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments wM 38 Coach Lane Property Address Thomas J..Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017 required for every y page. CibdTown State Zip Code Date of Inspection D. System Information (cost.) Type: ® leaching pits number: (1) ❑ leaching chambers number: ❑ Teaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): (1)6'x6' precast leachpit with stone.around, no signs of breakout or hydraulic failure, soils sandy with cobbles, leachpit dry at time of inspection, vegetation typical (lawn) Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction. Indication of groundwater inflow ❑ Yes ❑ No - t5ins.doc-rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 13 of 17 - Commonwealth of Massachusetts - Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments °wM 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is required for every Barnstable MA 02630 May 13, 2017 page. CityTTown State Zip Code Date of Inspection D. System Information (cont Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): Privy (locate on site plan): Materials of construction: Dimensions Depth of solids Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5ins.doc-rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 14 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments wM 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017 required for every y page. City,7own State Zip Code Date of Inspection D. System Information (cont.) Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ® hand-sketch in the area below ❑ drawing attached separately C) c� pP r�c�.W�t All << 3 1r �3 ` 1 � &[fi5 . t5ins.doc.rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 15 of 17 Commonwealth of Massachusetts _ Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13, 2017 required for every y page. City/Town 7State Zip Code Date of Inspection D. System Information (cont.) Site Exam: ® Check Slope ® Surface water ® Check cellar ® Shallow wells !Estimated depth to high ground water: >25 feet Please indicate all methods used to determine the high ground water elevation: ❑ Obtained from system design plans on record If checked, date of design plan reviewed: Date ❑ Observed site (abutting property/observation hole within 150 feet of SAS) ® Checked with local Board of Health -explain: GIS maps ❑ Checked with local excavators, installers-(attach documentation) ❑ Accessed USGS database-explain: You must describe how you established the high ground water elevation: Town of Barnstable Groundwater Contour Map indicates estimated high groundwater in this area to be +/-25' Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5ins.doc•rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 17 + v Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments wM 38 Coach Lane Property Address Thomas J. Mullen Owner Owner's Name information is Barnstable MA 02630 May 13 2017 required for every Y page. City/Town State Zip Code Date of Inspection E. Report Completeness. Checklist ® Inspection Summary: A, B, C, D, or E checked ® Inspection Summary D (System Failure Criteria Applicable to All Systems) completed ® System Information Estimated depth to high groundwater ® Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file t5ins.doc-rev.6/16 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 17 TOWN OF BARNSTABLE to LOCATION C }�� La�Je- SEWAGL-- VILLAGE �r ` ASSESSOR'S MAP & LOT o -� I SEPTIC TANK CAPACITY /000. LEACHING FACILITY:(type) (size) NO. OF BEDROOMS PRIVATE WELL OR PUBLIC WATER ft"UtC BUILDER OWNER M�l�ec► D: M DA D• V A- w, LEACH P T oil io AOL Sapr, r4,vk _ pvc u \Y, 4or In J 1 I � P i Pd cj�� LOCATION SEWAGE PERMIT NO. VILLAGE J I N S T A LLER'S NAME & ADDRESS R� fr OWNER fi ec--7 C , DATE PERMIT ISSUED DATE C0 P L I A N C E ISSUED �_��j l �� �� 1 6 G��ss � �� �° � �� �' �� r � b � � �v' No... FES....$ ........ THE COMMONWEALTH OF MASSACHUSETTS BOAR® OF HEALTH ....... ........Town--.........0F........Barnstable........ Appliration for BhipwiFal Works Tonstrnrtinn rumit Application is hereby made for a Permit to Construct ( ) or Repair ( ) an Individual Sewage Disposal System at: Coach Ln., ,Barns table,__MA 02630________ _________ . .............__... ........----...-----------.....--•--•------------•--------..........•......_..........-•-•--•-•-- Location-Address or Lot No. Maurice Wyman.... Coach Ln. . Barnstable_,.. ... 26�0 ---------- ---- .................... Owner Address a A & B Cesspool_Service 128 Bishops Terraces Hyannis, MA 02601 . . ........................... Installer Address d Type of Building Size Lot..... ......... .........Sq. feet a Dwelling—No. of Bedrooms.................4 Dwelling Attic ( ) Garbage Grinder ( ) 44 Other—Type of Building ............................ No. of persons.....................--..--- Showers ( ) — Cafeteria ( ) Pa Other fixtures -------- ------------------•---- . W Design Flow............................................gallons per person per day. Total daily flow............................................gallons. WSeptic Tank—Liquid capacity............gallons Length................ Width................ Diameter...------------. Depth................ x Disposal Trench—No. .................... Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No--------------------- Diameter.................... Depth below inlet.................... Total leaching area..................sq. ft. Z Other Distribution box ( ) Dosing tank ( ) Percolation Test Results Performed by...................................................................------ Date........................................ Test Pit No. 1................minutes per inch Depth of Test Pit...--..........--... Depth to ground water...--.............:..... (� Test Pit No. 2................minutes per inch Depth of Test Pit--.--............... Depth to ground water-------................. ---------------------------------- •---------------------------------------- *---------- -....... ••--- ------------------------ -........ •-------- *....... .------ 0 Description of Soil..............Sand.................................................................................................................................................... x W ------•-------- .....................................................................................................-------------------------------•-•------------•--•-------- :...---- VNature of Repairs or Alterations—Answer when applicable----ins.tallati.on__Qf..a._1_,-940..ga].1Qn..gxe- aSt, atone..gackea..leac-h..pit--(QYerflaw.).A.....................•--------------------------------------•------•-------------------••-......-•---•----••-----•---- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the T provisions of ?T p 5 of the State Sanitary Code— The undersigned further agrees not to place the system in operation until a Certificate of Compliance has been issued by the board o health. Date Signed..� �Git... � 81 6�80 Application Approved By... ................... 8 6 80 Date Application Disapproved for the following reasons:................................................................................................................ .........................................•............................................................................................................................................................... Date Permit No............. C ...........-......................... Issued...........8/ 6/80 ----------•._.....-•----... Date I � r� No...$Q.-.`��.:... Finc...$...t.Q.Q......... THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH .................. .III own............OF.......Barnstable. . ppliration for Disposal Works Tonstratrtiun rnmit Application is hereby made for a Permit to Construct ( ) or Repair ( ) an Individual Sewage Disposal System at: Coach Zn.. Barnstable. PIA. o2b30 - -••-----•••---- ---• ----------------•............•---...------•.........----...............--•--......--•----•------- ' Location-Address or Lot No. , Plaurice Wyman _ Coach Ln.� Barnstable, _NA 02630 ......................... Owner Address a A &B Cesspool Service 128 Bishops Terrace, Harnis� 11 02601 Installer Address QType of Building Size Lot..... ......... . .....Sq. feet Dwelling—No. of Bedrooms............. '...........................Expansion Attic ( ) Garbage Grinder ( ) aOther—Type of Building ............................ No. of persons--_.__4'_------............ Showers ( ) — Cafeteria ( ) Q, Other fixtures ................................. . <11 W Design Flow............................................gallons per person per day. Total daily flow............................................gallons. WSeptic Tank—Liquid capacity............gallons Length---------------- Width................ Diameter..._.- ------ Depth................ x Disposal Trench—No. .................... Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No--------------------- Diameter-------------------- Depth below inlet.................... Total leaching area..................sq. ft. Z Other Distribution box ( ) Dosing tank ( ) Percolation Test Results Performed by.......................................................................... Date........................................ Test Pit No. I................minutes per inch Depth of Test Pit.................... Depth to ground water........................ (i Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ a -----------------------------------------------------------•---......---------------•-----------------------------•-------•------••-•........................ ODescription of Soil.............2,arid........................---•---•---•-------------------------------------------------------•--------------------------------------•----•------ U ........................................................................................................................................................................................................ UNature of Repairs or Alterations—Answer when applicable._Amtallation--of-.a.-1.000_.ga11oT1__p2�-Cast, ... ye.rnQw) --------------------------------------------------------------------------------------------------------------•--•----- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of'IT�E, p 5 of the State>'Sanitary Code—The undersigned further agrees not to place the system in i operation until a Certificate of Compliance has been issued by the board of health. i Signed. ,��r-_... �! a-: = 8l 6180 ApplicationApproved By.`M-----•------------------•---...-•--•--•-•--------•--•----••----------•------------•-•---•- •-----....`--b -------•------ Date Application Disapproved for the following reasons---------------------------------------------------------------------------------•---------.. ---------•---- ..............?---.�.......------.. Issued.---------- .........................................0 Permit No....•----- 80- 8 0 Date 4 Date THE COMMONWEALTH OF WASSACHUSETTS tw BOARD OF HEALTH ,........................own........0F.......Barnstable................................................... CTrrtifiratr of ToutpliFaatrr THIS IS TO CERTIFY, That the Individual Sewage Disposal System constructed ( ) or Repaired (X ) by.A A 3_CessS iop Terrace. Hyannis. M 201__-� _ 7_ ....... 4 ,% Installer at. Coach-Ln., Barn stable, ' ...026 0 = -- Maurice Wyman has been installed in accordance with the provisions of TI T LE j of The State Sanitary Coe described in the application for Disposal Works Construction Permit No.80"'....f ................. da.ted......� ....180 --- - ------------------------- THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTAUED AS A UARANTEE THAT THE SYSTEM WILL FUNCTION SATISFACTORY. DATE.................---`--•--/ O.....................=---------------....-•---- Inspector---- .................. t THE COMMONWEALTH OF MASSACHUSETTS t BOARD OF HEALTH :�.:.T own..........O F................Barnstable i.. 5 ....................... .00 No............ ..... FEE................ ........ Disposal Works Tntnsira iott rrmtit Permission is hereby granted......A & B Cesspool Servi® ---------------------------------------------•---••-----------.....................-- to Construct ( ) or Repair (X ) an Individual ewage Disposal System at No........ oach_•Ln..:... stable, rTA 02 I - Ma.urice..F Street as shown on the application for Disposal Works Construction Per ' No80_Y14 Dated.. ,/L /�O.._l_V./-....._. ----------------- 80 F &rjd f Health DATE.................................6----� FORM 1255 HOSES & WARREN. INC.. PUBLISHERS THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH �.w1.Z................OF......... 19hzz- _ -------------------- --------------------•--.................... .. Appliratinn for Uhiposat Works Tous#rnrfinn Vrrmft Application is hereby made for a Permit to Construct (X) or Repair ( ) an Individual Sewage Disposal System at: Locatioq- ddres �` or Lot No. 1 !4..7_41 .. „O -----­--­---- wne r Address W Installer Address U Type of Building % 6 F —� Size Lot.. 5;V 2—�__...Sq. feet Dwelling—No. of Bedroomas...........................................Expansion Attic ( ) Garbage Grinder ( ) aOther—Type of Building ............................ No. of persons............................ Showers ( ) — Cafeteria ( ) P4Other fixtures -•--•--•----•.-----------••--...-•-----------------•--....-__--------- --•---•--•----------------------•-•--------------•------------ WDesign Flow......:.....................................gallons per person per day. Total daily flow---------_..................................gallons. WSeptic Tank—Liquid capacityJbA®___gallons Length................ Width---------------- Diameter---------------- Depth__-__________--- x Disposal Trench—No..................... Width.................... Total Length-------------------- Total leaching area--------------------sq. ft. 3 Seepage Pit No. _--- Diameter.................... Depth below inlet.................... Total leaching area___ ft. z Other Distribution box ( ) Dosing tank ( ) aPercolation Test Results Performed by.......................................................................... Date------------. ------------------------- Test Pit No. 1................minutes per inch Depth of Test Pit................_... Depth to ground water____________________._.. Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water--._____________--__--.- xDescription of Soil-----...... U -----------•----------------------•-------------------------......-------------•-•----------•••-----------------•--•-•-------.-- ----------- W ------------------------------------------------------------------------------------•----------------------------------------------------.----------------------------------------------------------- U Nature of Repairs or Alterations—Answer when applicable------------------------------------------------------------------------------------------------ ------------------------------------•------•--.-------------------------------------------------------------------------------------------------------------------------------------------------------- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of Article XI of the State Sanitary Code—The undersigned further agrees not to place the system in operation until a Certificate of Compliance has been issued e b e d f health. S' tied--( -------------•--•---- Application Approved B � �------- ------ 2-- ------. Date Application Disapproved for the following reasons--------------•---•-----•--------•-••--•--------------•-•-•-•-------•-•----•------------••----•••---------•-..._ . . ...--------•----------•-••-••---•-----------•... Date Permit No..../S-f------------------ ----------------------- Issued--- - --�--- - - ----- ------••--••-•--•------- Date -- ---..-----___'___'L!'------------ --- --------------J �n FuR THE COMMONWEALTH OF MASSACHUSETTS --BOAR® OF HEALTH $ Appliration for Dgopooal Workii Tatuitrurtion Vrrmit Application is hereby made for a Permit to Construct O or Repair ( ) an Individual Sewage Disposal System at - ---••-------- ----------- __ _.. ......... ............................................. Location-Address ^ or Lot No. Ow - Address a - --------------•------- -------------------------------------------------------------------------------------------------- st der Address Q Type of Building Size Lot._:_..__ _.Sq. feet Dwelling—No. of Bedrooms..__ ® _________________________•__-Expansion Attic ( ) Garbage Grinder ( ) aOther—Type of Building ____________________________ No. of persons---------------------------- Showers ( ) — Cafeteria ( ) p' Other fixtures ...................................................... W Design Flow............................................gallons per person per day. Total daily flow.............................................gallons. WSeptic Tank—Liquid capacity l O®-__gallons Length................ Width---------------- Diameter----------------Depth--._-.__-.-_---- x Disposal Trench=No. ...r............ Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No.-46------------------- Diameter.................... Depth below inlet..................... Total leaching area______�L sq. ft. Z Other Distribution box ( ) Dosing tank ( ) '-� Percolation Test Results Performed by............................................................-----•--•--- Date-------------------------------------..: aTest Pit No. 1................minutes per inch Depth of Test Pit.................... Depth to ground water.---__-___-__-___------. (T, Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ a - ODescription of Soil----------- �,��,-•. ------------------------------------------------------------------------------------------------------------------------------------------ W UNature of Repairs or Alterations—Answer when applicable.----------------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------•--•---•--•-----•------•--•---•-••--•------•-•-------••-----•--•-••-•......•-------•-••......---••-•---•-----.. Agreement The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of Article XI of the State Sanitary Code—The undersigned further agrees-not to place the system in operation until a Certificate of Compliance has bgqnq is d by the b Qd f health. ° � •-- Slgried------------•-•------'=----------- * ---- ......................... --•--••----Date a. Application Approved Bye' = =.......-__.�'_: �_ ----------------- --------� =®' Date Application Disapproved for the following reasons----------------------------------------------------------------------------------•--•-------......-----•-•--_... -------------------------------------------------------------------------•---------------------------------------- -------------------------}------ j= ------------------------------ •_ f 7 :. Date Permit No. - Issued.. r ' -Z-�°?....................... t Date THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH Trdifiratr of Tomplitturr THIS IS TO CERTIFY, That the Individual SKsta!ile'ae Disposal&qqm onstructed e;�or Repaired ( ) by .... ..--••--•------- . •. . ---- -------------------•------•-------•••••--•- _( �+ d 'topr �F d at -- r- ---------: i1s ... r .. .............. '' .. ........................- ._.. ............................................................ has been installed in accordance with the provisions of Article„X4 of The State Sanitary Code as_described in the 42. application for Disposal Works Construction Permit No------ fix........................ dated....� ._ __.._ -.--.--•--•.-_- THE ISSUANCE OF THIS CERTIFICATE SHALL�NOT BE CONSTRUED AS A GUARANTEE THAT THE E SYSTEM 14,. QNCTION SATISFACTORY. DATE...... =` -------------------------•------ Inspector - �� _ -- �.� l THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH ........... .., .... - No....=t ---•------- FEx' .................. 'Di,gvoiittl ork_q Tonstrurfiall Prrinit Permission is hereby granted---_-------------------- __________ to Construct., (, or Repair ( ) an Individual Sewage Disposal System at NO.... bL f P i t , cam{ X,l; =' 3 -"' •- '�, W e'= s Yr t as shown on the application for Disposal Works Construction /Pt No 6._._ d.. _ Board of Health DATE--- FORM 1255 1BBS &-WARREN• INC.. PUBLISHERS - • I