Loading...
HomeMy WebLinkAbout0227 SALT ROCK ROAD - Health 227 SALT.ROCK ROAD Barnstable A 316'= 01,7 r T r N '' - Fee THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: PUBLIC HEALTH DIVISION - TOWN OF BARNSTABLE, MASSACHUSETTS Yes 0[pplitation for -Misposal 6pstem Construction Permit Application for a Permit to Construct( ) Repair(,/) Upgrade( ) Abandon( ) Complete System ❑Individual Components Location Address or Lot No. 1'L1 Sal+ Roc.K 9,oad Owner's Name,Address,and Tel.No. Pedro ftkCturo Assessor's Map/Parcel a4rn0,o51e, 21.1 SoMr Roa- Rood (�o.rn5}o.bla 31(0 1 Installer's Name,Address,and Tel.No. (j'S 4 q_i co vcA t)c, Inc.. Designer's Name,Address,and Tel.No.F lch4*f`FA 4rc.nu;r0M¢ 1 3-+,1 aoo+a vw So.ndw%c,, 5177" 4463 PO boK 3sl Koct,j ►, NAo, OZbNS Type of Building: Dwelling No.of Bedrooms 3 Lot Size 39 c ORZ sq.ft+- Garbage Grinder(No) Other Type of Building No.of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow(min.required) 3 3 0 gpd Design flow provided 34 b gpd Plan Date (o- 'L• 20 Z O Number of sheets 2- Revision Date Title Size of Septic Tank 1500 qo,\\on Type of S.A.S. (Z) 500 Qa«on Oio w%bers Description of Soil Sae plo.ns Nature of Repairs or Alterations(Answer when applicable) Ir1S�gU niLu 1500 4c611or• Sgf? ;G -}O.t\l- _ D•box and SAS +o rcplo ce C-eSSpools. Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certificate of Compliance has been issued by this Board of Health. S' ned Date (o' ZO ti.0 Application Approved by Date a& Application Disapproved by Date for the following reasons Permit /& 2 Date Issued a Nod _ '"'�!-� F i s ! Fee 101 THE COMMONWEALTH OF MASSACHUSETTS 'Entered in computer: PUBLIC HEALTH DIVISION - TOWN OF BARNSTABLE, MASSACHUSETTS Yes application' for Niposa-6pstem Construction Permit Application for a Permit to Construct( ) Repair(.f) Upgrade( ) Abandon( ) Complete System ❑Individual Components Location Address or Lot No. 'j 11 S o%1+ R o r.k Road. Owner's Name,Address,and Tel.No. Pe d r u ck u r o Assessor's Map/Parcel1b 1 21 r `�@1� Roc1c 1�oracl �o:nStc.�,1 Ins aller's Name,Address,and Tel.No. Q,$Q) rr_x c o vccA � i n c.. Designer's Name,Address,and Tel.No.F 4 a1;Qr`Fy cvr,�4 }�1 3_'4 a't.ovie `I i7 rJandw.<ti. 1517i'- e(o63 ?p bu 331 Ko,3"(,t, M0, 021,�15* Type of Building: Dwelling No.of Bedrooms 3 Lot Size 39, 0CQ sq.ft. Garbage Grinder(Wo) Other Type of Building No.of Persons Showers( ) Cafeteria( ) t, Other Fixtures Design Flow(min.required) 3' 0 gpd Design flow provided $ gpd Plan Date (0, 2 , 2-0 2-0 Number of sheets 2- Revision Date Title Size,of Septic Tank 1500 0n&\�Un Type of S.A.S. T) 500 c\C kkori 0,e. 4_r�, Description of Soil 5u e o o,n s i 3 y E Nature of Repairs or Alterations(Answer when applicable) l h`,)�e,11 n 2 y 1500 ao,1ko n S,p ,c Atli(*. CieS5pool s, r, Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in r accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certificate of Compliance has been issued by this Board of Health. S(i ed 4 Date (o' 4' 20-0 Application Approved by \ Date all?1 ... Application Disapproved by � Date, for the following reasons Permit No: 4;LO /& Date Issued lf� / , ---------- , THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE,MASSACHUSETTS (Certificate of Compliance THIS IS TO CERTIFY,that the On-site Sewage Disposal system Constructed( ) Repaired(✓) Upgraded( ) Abandoned( )by at 2?_I '�a 1-k lock Re)cx d has been constructed in accordance with the provisions of Title 5 and the for Disposal System Construction Permit dated 6 �/� �C) . Installer ('3 3 (3 `_Y_( Q nA o- fi r),, Designer l ahe r- #bedrooms Approved design flow, ✓ � _ _ gpd The issuance of this permit shall not be construed as a guarantee that the system wil�ti on as desi` gned(., Date f d e� Inspector AdI t,a I ;? -- -------- _ __-- - - No -" /� Fee THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION-BARNSTABLE,MASSACHUSETTS Disposal *pstem Construction Permit Permission is hereby granted to Construct( ) Repair(A Upgrade( ) Abandon( ) System located at �A1A Roc k't ?)tia eL and as described in the above Application for Disposal System Construction Permit. The applicant recognized his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided:Construction must Ibye comp eted within three years of the date of this permit. Date 6(✓ f t Approved by �ti TOWN OF BARNSTABLE LOCATION 2 Z') SgJA R=k RaL SEWAGE# Z O ZO- /LiT VILLAGE Tf�hL'l oLl P ASSESSOR'S MAP&PARCEL 3!(,- or �/z INSTALLER'S NAME&PHONE NO. 6,�$ ExeouJaA►on 4'11-DGS3 SEPTIC TANK CAPACITY /S'OO cja j LEACHING FACILITY:(type) ) (J�c(Z' (size) 13 x 2Sx 2 NO.OF BEDROOMS OWNER PERMIT DATE: (o-$- ZO COMPLIANCE DATE: 2 v Separation Distance Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet Private Water Supply Well and Leaching Facility(If any wells exist on site or within 200 feet of leaching facility) ' Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leaching facility) Feet FURNISHED BY Al- Z� ' 0 2 a 7 r= Ik P.�C. << 2$ Ll Az' 32'Z - SZ.30 s REAR A A3• 33'$ Q3. X IS Ay, 4zlZil O 4 32�L m Town of Barnstable Inspectional Services Public Health Division �nursraeLe: NAM Thomas McKean,Director ? .bs9. 200 Main Street,Hyannis,MA 02601 - T Office: 508-8624644 Fax: 508-790-6304 (, Installer& Designer Certification Form. Date: - 1 Z•2(0 Sewage Permit# ZoZo- 1 L:j Assessor's Map\Parcei 3)L-In Designer: Fla1,�r�►� Er,�;ro�.Ln'1«1 Installer: f3 E�cco�d�ior� Address: p n S3ox 331 r ; h Address: ILA IcaScrrc L.,3 O Z 1.L-1 S res-1 0ko.-1 L On C,•S-Zo G 4 3 EXcayca_ai c n was issued a permit to install a (date) (installer) septic system at 771 So-1A Rock RcL based on a design drawn by (address) � •�e �lo��er•�c r dated La-Z-ZO (designer)` I certify that the septic system referenced above was installed substantially according to the design, which may include minor approved changes such as lateral relocation of the distribution box and/or septic:tank. Strip out (if required) was inspected and the soils were found satisfactory. I certify that the septic system referenced above was installed with major changes (i.e. p greater than 10' lateral relocation of the SAS or any vertical relocation of any component of the septic system) but in accordance with State& Local Regulations. Plan revision or certified as-built by designer to follow. Strip out (if required) was inspected and the soils were found satisfactory; I certify that the system referenced above was:constructed i e om YA e with the terms of the RA approval letters (if applicable) y,�A`� s&. DAVID oyGN o. D. FLAHERT 6 JR. (I taller's Si natbre) — Na. 12110 Q/sTV- S'9NITAR\P� esigner's Signatur (Affix Designer's Stamp Here) PLEASE RETURN TO.BARNSTABLE PUBLIC HEALTH DIVISION. CERTIFICATE OF COMPLIANCE WILL NOT BE ISSUED UNTIL BOTH THIS FORM AND AS- BUILT CARD ARE RECEIVED BY THE BARNSTABLE PUBLIC HEALTH DIVISION. THANK YOU. Woa\deptAHEALTMSEWER connecASEPTIMesigner Certification Form Rev&14.13.DOC COVERS TO BE WATERTIGHT AND SEPTIC SYSTEM PROFILE r Flaherty Environmental Services TOP OF FOUNDATION BROUGHT TO WITHIN 6" OF FINAL GRADE EL. 58.0' EL. 56.0' (not to,scale) INSP. PORT W I 3" OF GRADE CLEAN SAND P O. Box 331 2" of�" to 1" DOUBLE WASHED EL. 56.0' Harwich, MA 02645 4" CAST IRON or EQUIVALENT PEASTONE OR GEOTEXTILE 774.994.1166 MIN. PITCH 1/4" PER FOOT FILTER FABRIC ` 4"SCHEDULE 40 PVC PIPE 4"SCHEDULE 40 PVC PIPE VENT IF REQUIRED FLOW LINE (first 2'to be/aye/) 5' 2.2% 5, 1% °O°°°o°C —.- inn �.. . o 000 °o°oc REQUIRED: L.55.9' 10 14" �• o 0 0 0 5' REMOVAL OF —+� °°°°°O°°°°° ° ®1��LJ •�0 °°°°°°°°° EL.54.0.' EL.53.75' —� o 0 0 ° ° o 0 0 0 p p p o 0 0 o a 0 0 0 0 0 0 �® O� L._1 0 0 0 o UNSUITABLE EL.53.03' o° o°o°o°o°o°o •�, (� o°o°o°o°c 2.0' MATERIAL LATERALLY AND • EL.53.2' o0000000 �® Pmgln pl� oo ooe— o 0 0 0 0 0 `—i o 0 0 0 0'MIN.(2.5Mo1— EL 53.0' o 0 0 0 0 0 0 089 0 0 0 0 GAS BAFFLE °o°o°o°o°o o°o°o° a .' + °o°o°o°oc BENEATH SAS TO EL. 50.6' (H-20 D-BOX) 0°0°000°0 00°0°0 .. •• • • °0°o0000C EL.51.0' 6"CRUSH D sTONE OR SOIL ABSORPTION SYSTEM ,. MECHANICALLY COMPACTED (2) 500 GALLON H-20 CHAMBERS (DATUM: ASSUMED) WITH 4' STONE AROUND IN A 5.5' 1500 GALLON SEPTIC TANK 4 to 12 DOUBLE WASHED STONE 12.83'X 25'X 2' CONFIGURATION (PROPOSED) �' BOTTOM OF TEST HOLE EL. 45.5' EL. 45.5' `y USGS ADJUSTMENT: N/A LOCATIONMAP 54 GROUNDWATER ELEV: N/A Rt.6A 4 BENCHMARK: TOP OF FNDN EL. 60.0' Z Salt Rock Rd 54 N TH • o ui o ® m Cu N Q LOCUS II I O ', EXIST. C.P. EXIST. C•P, NTS 5 CP CP O 2 EXISTING 3 BR I O �14 OF PROP. S.T. DWELLING 40,9' 46.0' 1 D D IN O DECK 1 / Q F NV H 21 �`• — -- ,s. r. GARAGE �'IiI,TAA� *I CIN Cl) DRIVEWAY V•_ V 1 THE H-2 _ — — — — — — — DATE:6/2/2020 REVISED: {,Y� 56 41.9' LOT 13 1 LEGEND 39,092 SFf I SITE AND SEWAGE PLAN FOR -6 6 b b GAS LINE MAP 316 LOT 17 I B& B EXCAVATION, INC./ `-` WATER LINE 58 PEDRO MADURO E E 6 E E EXIST. ELECTRIC I 227 SALT ROCK ROAD 99 EXIST. CONTOURS 11 _ t BARNSTABLE, MA 58 ————— 99 PROP. CONTOURS SCALE : 1 - 3 N46--;A& WAS UNDERGROUND UTIL REF•PB 222 PG 85 PAGE 1 OF2 ......... ........... .. ......... . . . ........ ....... . . ......... ....... ....... . ......... . .. .. .... .. ...-._. . ........._ ......... ......... ........ ......... ........ ............. ............ GENERAL NOTES DESIGN CALCULATIONS SYSTEM DETAIL Flaherty Environmental Services 1. ALL PRECAST COMPONENTS TO BE H-10 P. 0 . BOX 331 RATED UNLESS OTHER WISE SPECIFIED. Harwich, MA 02645 DISTRIBUTION BOX AND ANY COMPONENTS NUMBER OFACTUAL BEDROOMS 3 774.994. 1166 WITH ANY ANTICIPATED VEHICULAR TRAFFIC TO BE H-20 RATED, GARBAGE DISPOSAL UNIT NO 2. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OFA GARBAGE TOTAL ESTIMATED FLOW GRINDER. (110 GAL/BR/DAYX 3 BR) 330 GAL./DAY 3. MUNICIPAL WATER IS AVAILABLE. REQUIRED SEPTIC TANK CAPACITY 660 GAL. 5' REMOVAL 4. ALL CONSTRUCTION TO CONFORM WITH 25' 310 CMR 15.000 AND ALL OTHER SIZE OF SEPTIC TANK 1500 GAL. (PROPOSED) APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS. SOIL CLASSIFICATION 1 5. INSTALLER/CONTRACTOR TO REVIEW& VERIFY ALL ELEVATIONS AND DETAILS AND DESIGN PERCOLATION RATE <2 MIN./INCH REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO CONSTRUCTION OR EFFLUENT LOADING RATE 0.74 GAL./DAY/FTZ O Q 12,83' ASSUME ALL RESPONSIBILITY LEACHING AREA 6. INSTALLER/CONTRACTOR IS RESPONSIBLE (2)x(25.0'+ 12.83)(29 = 151 SF FOR MAINTAINING SAFE WORK AREA, 25.0'x 12.83' =320 SF VERIFYING ALL UTILITIES AND NOTIFYING 471 SF 0.74 =348 GPD_ "DIG SAFE" (1-888-344-7233) 72 HOURS PRIOR TO CONSTRUCTION. USE(2)500 GALLON H-20 CHAMBERS WITH 4'STONE IN A 12.83'X 25'CONFIGURATION AS DIAGRAMMED 5'REMOVAL REQUIRED LATERALLY 7. ANY CHANGES TO OR DEVIATIONS FROM AND BENEATH PROPOSED SAS TO THIS PLAN MUST BE APPROVED IN c2 LAYER ELEV.5o.s'(VAR/ABLE). WRITING BY FLAHERTY, ENVIRONMENTAL I SERVICES AND LOCAL BOARD OF HEALTH. RESERVE LEACHING CAPACITY N/A 8. FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3'PER 310 CMR 15.000 UNLESS SHOWN PER PLAN. 9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE PUMPED DRY AND (NTS) FILLED WITH CLEAN SAND OR REMOVED AND REPLACED WITH CLEAN SAND. 10.ALL COMPONENTS TO BE PROVIDED WITH SOIL EVALUATION WATERTIGHT ACCESS PORTS WITHIN 6 OF TEST HOLE#1 TPT#20-88 TEST HOLE#2 TPT#20 88 FINISH GRADE. Evaluator- David D.Flaherty Jr.,RS,REHS Evaluator., David D.F/ahertyJr.,RS,REHS 11.ALL SEPTIC TANKS, DISTRIBUTION BOXES SE#2755 SE#2755 �k7" AND PIPING TO BE INSTALLED BOH Witness: Don Desmarais,RS BOH Witness: Don Desmarais,RS WATERTIGHT. Date:. May 19,202o Date: � May>s,2020 12.NO KNOWN WETLANDS OR WELLS WITHIN 0, 1 TH-1 ELEV.56.0' TH-2ELEV.56.0' 150 FEET OF PROPOSED LEACHING. 13.THIS IS NOT A CERTIFIED PLOT PLAN AND o~-fo" A Ls 10YR 3/2 0~-f0" A LS fOYR 3/2 �41eTE¢ UNDER NO CIRCUMSTANCES IS THIS PLAN a�a1.T���a TO BE USED FOR ZONING OR BUILDING PURPOSES. 10"-29" B LS 10YR 5/6 10"-29" B LS iOYR 5/6 14.LOT IS SHOWN AS ASSESSOR'S MAP 316 LOT 17, /certify that on November 12,2002,l have passed SITE AND SEWAGE PLAN 29"-65" C1 Silt 10YR 6/4 29"-65" C1 Silt IOYR 6/4 15.LOCUS PROPERTY IS NOT LOCATED the examination approved by the Department of WITHIN AN AQUIFER PROTECTION Environmental Protection and that the above analysis FOR has been performed by me consistent with the g & B EXCAVATION INC./ DISTRICT(ZONE II). required training,expertise,and experience described i sieve sample in 310 CMR 15.018(2)." PEDRO MADURO 65"-132" C2 MS 2.5Y6/6 65"-120" C2 MS 2.5Y6/6 227 SALT ROCK ROAD BARNSTABLE, MA G.W.ELEV.N/A G.W.ELEV.N/A BOTTOM TH-1 ELEV.45.5' BOTTOM TH-2 ELEV.46.0' PAGE 2 OF 2 DATE:61212020