HomeMy WebLinkAbout0155 SOUTH FLINT ROCK ROAD - Health M'
i9S ALPINE WAY
-Barnstable,
11
i
i
i
w Massachusetts Department of Environmental Protection 313
Bureau of Resource Protection I
Well Completion Reports
< V .
Well Driller
Please specify work performed: Address at well location:
New Well Street Number: Street Name:
93 ALPINE WAY
Please specify well type: Building Lot#: Assessor's Map#:
Irrigation 081 ;
Assessor's Lot#: ZIP Code:
Number Of Wells: 022 102648
Cityrrown:
Well Location BARNSTABLE
In public right-of-way: GPS
tom( Yes r_No North: West:
41.67517 70.40714
Subdivision/Property/Description: -
Mailing Address: _
__.._..click here if same as well location address
Property Owner: Street Number: Street Name:
JONATHAN FAIN 93 ALPINE WAY
City/Town: State:
Engineering Firm: BARNSTABLE MASSACHUSETTS
ZIP Code:
02648
Board of health permit obtained:
�t Yes r Not Required
Permit Number: Date Issued:
W2020 016 '05/26/2020
._........_......._..........._......_............:_
Massachusetts Department of Environmental Protection
® Bureau of Resource Protection—Well Driller Program
Well Completion Reports(General)
Well Driller - General Well Form
DRILLING METHOD
Overburden Bedrock
I uger Choose Bedrock-- I
WELL LOG OVERBURDEN LITHOLOGY
Drop in drill ;Extra fast or slow Loss or addition
�From(ft) To(ft) Code Color Comment
stem !drill rate of fluid
0 115 [Si I Cla �. Brown * i`Fast 4"Slow
1LYES NO Loss Addition
15 35 Fine To Coarse S'- BrownF f i 1 (�`Fast f Slow
� ,
j YES NO j Loss Addition
.............
_...._
35 � 40 Fine To Coarse S ,Brown I (" ` f~Fast r Slow I i
s
YE S N0 j Loss Addition i I
WELL LOG BEDROCK LITHOLOGY
Loss or I Extra
Drop in Extra fast or Visible Rust
From(ft) �To(ft) Code Comment addition of � Large
drill stem slow drill rate Staining
fluid i Chips
f j Choose Code +. j�Yes! r Yes
s 6. 7SNO Ej Fast Slow ] Loss Addition l -- � I
................................
..............................
.
.....................
....................
ADDITIONAL WELL INFORMATION
Developed 4r Yes i No Disinfected Yes f No (
........... _...__........._.................._I
Total Well Depth 40 Depth to Bedrock
Surface Seal Type None �racture Enhancement 'Yes f No
CASING r Is Casing above ground?j
From To Type Thickness Diameter Driveshoe '
0 34 Polyvinyl Chloride !Schedule 40 Imo:Yes j
I... _ .........._.
SCREEN Screen '
l From it No To Type Slot Size Diameter
_.
34 40 Stainless Steel Well point � 6-12 I;=
WATER-BEARING ZONES IF DRY WELL!
From To Yield(gpm)
15 40.._..__....._..` 15
PERMANENT PUMP(IF AVAILABLE)
3 Wire Variable Speed
Pump Description Horsepower -
Submersible
Pump Intake Depth(ft) 33 Nominal Pump Capacity(gpm) 65
71 Massachusetts Department of Environmental Protection
Bureau of Resource Protection—Well Driller Program
Well Completion Reports(General)
ANNULAR SEAL/FILTER PACK
From To Material 1 Weight Material 2 Weight Water Batches Method Of
(gal) (count) Placement
i
E= i Choose Mate Choose Material J1 (� (j r Choose One
WELL TEST DATA
_........__..........___..................._._._.-......_...................................._.-__.__._..._......._-..__...._....--._................_._.._ .__....
Time Pumped Pumping Level(ft Time To Recover Recovery(ft
f Date Method Yield(gpm) (HH:MM) BGS) (HH:MM) BGS)
OS/27/2020 Constant Rate Pump 15 01.30 16� 00,01 � 15
WATER LEVEL
I Date
Static Depth BGS(ft) Flowing Rate(gpm)
Measured
05/27/2020 15
COMMENTS
WELL DRILLERS STATEMENT
This well was drilled or altered under my direct supervision,according to the applicable rules and regulations,and this report is complete
and accurate to the best of my knowledge.
DESMOND
THOMAS E Monitoring 1M] Supervising Driller Signature III,
DrillerDESMOND III Registration# 764 THOMAS,E
DESMOND WELL __
Firm DRILLING INC. Rig Permit# 0089 Date Job Complete ros/o4/2o2o
NOTE:Well Completion Reports must be filed by the registered well driller within 30 days of well completion.
EN IROTEC I.,ABOR f TORIES,1VC.
1 IA CERT. NO.: MA 061
ft Just Sebastian DHt e Gtrtit.
Sandwich.KA 02563
(509)888-6460 1-806L339-6460
FAX(508)8884446
Client 1Vt1me, Desmond well Drilling Locatic;n.
Address .- PO Box 2783 95 Alpine Way
Orleans, MA Marstons Mills,MA
02653 Lab Number: DW-201381
Collected.By:. Desmond Date Receivetl: 05/28/20
Sample Type: Irrigation dell Specs Deep 40'Static 15'
Awl
Analysis Requaved Units Reconrrrtended Limits Analysis Result I lifethnd [RateAnalyzedj Analyzzed By
W Total Coliform CFU/t06ML 0 Absent, SM02228 05128/2020 KB @'16:46
�. _ ......
p pH units 6.5-8.5 � .._. 5.89 SM 4500-H-B 05�2
H _ _ 2812020 Kt
Specific Conductances � umhos/cm. 500 102 EPA 120.1 05128/2020 K .... e_
_ F
<._. ...... _.m.._�._.
Nitrite-N ___ _... -mg/L 1 00 <0.006. EPA 300.0 05/28/202�T K
0 KF
_Nitrate-N _.__._. . � �.._. _. _. �-. _ ._...
g/L 10.0 0.05 EPA 300.0 05/28/2020 KF
_-_— _ _._.,. ,;
Sodium m,/L 20.0 13 EPA 200.7 0 9 5/29/2020 KB
Total Iron mg1L 0 3 0.03 EPA 200.7 05/29/2020 KB
....... ___ _.._. ........... _. _ .
Manganese mg/L 0.05 0.018 EPA 200.7 05/29/2020 KB
Comments:
Low pH indicates high corrosive characteristics,
All samples were analyzed within the established guidelines of US EPA approved methods with all requirements met,
r
unless otherwise noted at the end of a given sample's analytical results.
We certify that.the following results are true.and accurate to the best of our knowledge.
Water meets EPA standards and is suitable for drinking for parameters tested.,
Date 5/29/2020
Ronrildl Saa i
Labopratory Direct r "
BPL=Beldu,.Reportable Limits *See Attached Page 1 of 1
❑Cerlii cation is not available fot'this analyte for potable ivat&samp/es..
s